BRR : 8796988
Tender Brief : Rate Contract Of Supply Of Different Material For Divisional Workshop To Carry Out Transformer Repairs And Mccbs-2 Dpc Copper Winding Wire ( Round ) In Sizes 11 To 22 Swg 3 Se Aluminium Winding Wire ( Round ) In Sizes 12 To 20 Swg 4 Glass Wool Sleeves Of Sizes 5 Hv Bush Clamps ( Ms ) 6 Al. Clamping Member ( Shoes ) For Hv Bushing 7 Nuts & Bolts ( M.S ) Of Sizes. 8 Synthetic Enamel Paint Smoke Grey Colour 9 Paint Thinner 10 Steel Primer 11 Welding Rods 3.15 Mm / 4Mm. ( Packet Containing 100 Nos ) 12 630 Amp 3 Pole Thermal Magnetic Mccbs Having Adjustable Therma... Read More
Tender Value
₹
Ref. Document
Submission Date
28-12-2020
Participated Bidder List
4 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | |||||
| 4 | cnet-technologies | Bid Analytics |
Work Detail
rate contract of supply of different material for divisional workshop to carry out transformer repairs and mccbs-2 dpc copper winding wire ( round ) in sizes 11 to 22 swg 3 se aluminium winding wire ( round ) in sizes 12 to 20 swg 4 glass wool sleeves of sizes 5 hv bush clamps ( ms ) 6 al. clamping member ( shoes ) for hv bushing 7 nuts & bolts ( m.s ) of sizes. 8 synthetic enamel paint smoke grey colour 9 paint thinner 10 steel primer 11 welding rods 3.15 mm / 4mm. ( packet containing 100 nos ) 12 630 amp 3 pole thermal magnetic mccbs having adjustable thermal ( 0.8 in-1.0 in ) . with fixed magnetic setting of 10*in, breaking capacity not less than 50ka ( ics=icu=100% ) , with spreader links, phase barriers, & direct mounting rotary operating mechanism ( rom ) . the rom shall be lockable in off position. the mccb should be ce marked and shall conform to iec:60947-2-2003 standards. the mccb shall have a maximum operational voltage ( ue ) 690v, insulation voltage ( ui ) 1000v, and impulse withstand voltage ( uimp ) 8kv. mccbs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: on, off and tripped, total opening time <10msec, mechanical life 25000 operations & electrical life @415v ac 10000 operations. n ( make: abb / eaton / havells / legrand / l&t / schneider / siemens ) 13 400 amp 3 pole thermal magnetic mccbs having adjustable thermal ( 0.8 in-1.0 in ) . with fixed magnetic setting of 10*in, breaking capacity not less than 50ka ( ics=icu=100% ) , with spreader links, phase barriers, & direct mounting rotary operating mechanism ( rom ) . the rom shall be lockable in off position. the mccb should be ce marked and shall conform to iec:60947-2-2003 standards. the mccb shall have a maximum operational voltage ( ue ) 690v, insulation voltage ( ui ) 1000v, and impulse withstand voltage ( uimp ) 8kv. mccbs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: on, off and tripped, total opening time <10msec, mechanical life 25000 operations & electrical life @415v ac 10000 operations. n ( make: abb / eaton / havells / legrand / l&t / schneider / siemens ) 14 200 amp 3 pole thermal magnetic mccbs having adjustable thermal ( 0.8 in-1.0 in ) . with fixed magnetic setting of 10*in, breaking capacity not less than 50ka ( ics=icu=100% ) , with spreader links, phase barriers, & direct mounting rotary operating mechanism ( rom ) . the rom shall be lockable in off position. the mccb should be ce marked and shall conform to iec:60947-2-2003 standards. the mccb shall have a maximum operational voltage ( ue ) 690v, insulation voltage ( ui ) 1000v, and impulse withstand voltage ( uimp ) 8kv. mccbs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: on, off and tripped, total opening time <10msec, mechanical life 25000 operations & electrical life @415v ac 10000 operations. n ( make: abb / eaton / havells / legrand / l&t / schneider / siemens ) 15 160 amp 3 pole thermal magnetic mccbs having adjustable thermal ( 0.8 in-1.0 in ) . with fixed magnetic setting of 10*in, breaking capacity not less than 50ka ( ics=icu=100% ) , with spreader links, phase barriers, & direct mounting rotary operating mechanism ( rom ) . the rom shall be lockable in off position. the mccb should be ce marked and shall conform to iec:60947-2-2003 standards. the mccb shall have a maximum operational voltage ( ue ) 690v, insulation voltage ( ui ) 1000v, and impulse withstand voltage ( uimp ) 8kv. mccbs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: on, off and tripped, total opening time <10msec, mechanical life 25000 operations & electrical life @415v ac 10000 operations. n ( make: abb / eaton / havells / legrand / l&t / schneider / siemens ) 16 100 amp 3 pole thermal magnetic mccbs having adjustable thermal ( 0.8 in-1.0 in ) . with fixed magnetic setting of 10*in, breaking capacity not less than 50ka ( ics=icu=100% ) , with spreader links, phase barriers, & direct mounting rotary operating mechanism ( rom ) . the rom shall be lockable in off position. the mccb should be ce marked and shall conform to iec:60947-2-2003 standards. the mccb shall have a maximum operational voltage ( ue ) 690v, insulation voltage ( ui ) 1000v, and impulse withstand voltage ( uimp ) 8kv. mccbs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: on, off and tripped, total opening time <10msec, mechanical life 25000 operations & electrical life @415v ac 10000 operations. n ( make: abb / eaton / havells / legrand / l&t / schneider / siemens ) 17 40 amp 3 pole thermal magnetic mccbs having adjustable thermal ( 0.8 in-1.0 in ) . with fixed magnetic setting of 10*in, breaking capacity not less than 50ka ( ics=icu=100% ) , with spreader links, phase barriers, & direct mounting rotary operating mechanism ( rom ) . the rom shall be lockable in off position. the mccb should be ce marked and shall conform to iec:60947-2-2003 standards. the mccb shall have a maximum operational voltage ( ue ) 690v, insulation voltage ( ui ) 1000v, and impulse withstand voltage ( uimp ) 8kv. mccbs shall be actuated by a rotary-handle that clearly indicates the three distinctive positions: on, off and tripped, total opening time <10msec, mechanical life 25000 operations & electrical life @415v ac 10000 operations. n ( make: abb / eaton / havells / legrand / l&t / schneider / siemens )
View Original Notice/Document