BRR : 2152684
Click Here To View Tendering Authority. Aoc City/State :  ALUMINA REFINERY, NALCO, DAMANJODI, Odisha
Tender Brief : Installation N Commissioning Of 11 Kv Switch Board 1Ha At Spp , Nalco , Damanjodi , Dismantling Of 11 Kv Ht Double Bus , Abb Make , Switchboard No . 1Ha In Shipping Section ( Panel Wise ) At Unit#1 Boiler Switchgear Room Including Disconnection Of Power & Control Cables In Each Panel And Removal Of Existing Panel From The Foundation & Shifting The Panels From Spp To A Site Location As Per Direction Of Engineer-In-Charge . All Labour & Materials As Required Shall Be Under The Scope Of The Party . The Job Needs To Be Executed In Time Bound Period To Restore The Power Supply To Boile... Read More
Tender Value
Ref. Document
Contract Value
₹ 7,72,700
Submission Date
24-02-2020
Contract Date
01-05-2020
Completion Date
365 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 15,68,750 L3
2 cnet-technologies Bid Analytics 7,72,700 L1
3 cnet-technologies Bid Analytics 8,78,800 L2
Work Detail
installation n commissioning of 11 kv switch board 1ha at spp , nalco , damanjodi , dismantling of 11 kv ht double bus , abb make , switchboard no . 1ha in shipping section ( panel wise ) at unit#1 boiler switchgear room including disconnection of power & control cables in each panel and removal of existing panel from the foundation & shifting the panels from spp to a site location as per direction of engineer-in-charge . all labour & materials as required shall be under the scope of the party . the job needs to be executed in time bound period to restore the power supply to boiler#1 . the switchboard comprises of the following panels . a . incomer & transformer panels: 08 nos . b . potential transformer panels: 04 nos . c . cable termination panel: 01 no . shifting of new 11kv panels from central stores/storage area to boiler#1 mcc room . each panel weighing approximately 900 kgs & total nos . of panels: 13special care is to be adhered while shifting by hydra/trawler etc so as not to damage the panels . , erection , commissioning and alignment of new 11 kv ht panel with each panel weighing around 1200 kg & size 600 mm x 2150 x 2660 ( wxdxh ) approximately which comprises of transformer feeder / incomer /bus pt ( vacuum circuit breaker panel ) , including all accessories , metering , protection , alarms etc . after necessary foundation work in the existing location , including grouting , making holes , masonary works etc as required . shifting of panels from central stores to spp unit#1 switchgear room . the panels must be shifted through truck/trawler and not hydra & transportation is under the scope of the party . all labor , materials shall be arranged by the party . panel main busbar interconnection for power , control circuits etc complete and reconnection of power & control cable to respective panels are under the scope of the party . fabrication materials like ms channel/ angle shall be supplied by nalco . the party has to extend necessary man power assistance during testing & commissioning of panels . the new 11 kv switchboard comprises of the following panels . a . incomer & transformer panels: 02 nos . b . transformer panels: 09 nos . c . potential transformer panels: 01 nos . , fabrication of 11 kv switchboard base frame at as required with ms channel of size 100 x 50 x 6 and angle of size 50x50x6 including masonary work grouting , as required as per direction of engineer in charge at location spp 2ha , 3ha & ls02 switchboard . , two numbers of the transformer feeder shall be shifted to ls 02e & 01 nos . each to #1ha & #3ha switchgear room . erection , commissioning of the old 11 kv ht panel with each panel weighing around 1200 kg & size 850 mm x 1950 x 2800 ( wxdxh ) after necessary foundation work in the new location after making suitable arrangement for foundation including grouting , making holes , masonary works as required complerte . panel bus bar interconnection for power bus , control circuit are under the scope party . necessary modification of bus-bar shall be carried to enable coupling with exsting 11 kv bus . all bus bars shall be provided by nalco . location of addition of switchboard shall be:a ) 11 kv switchboard of ls-02e: 02 nosb ) 11 kv switchboard of boiler- 2ha & 3ha:02 nos . , supply , fabrication & laying of gi earthing strips of following sizes for the 11 kv switchboard , a . gi earth strip size 75 x10 mm , dismantling & shifting of double bus ht panel to knock down condition with separating each component & transporting the dismantled components to us 03ex for storage . the panel list include:a ) incomer panel: 02 nosb ) transformer panel: 02 noc ) pt panel: 04 nosd ) bus trunking panel: 01 no , obtaing statutory clearance from cea , laying of ht/lt/ communication cable for relay networking cable at #1ha switchboard for rerouting of existing cable as per site requirement and location of feeders including clamping of cables in the existing cable tray . , a . 11 kv xlpe cable of size 3cx300 & 1cx 630 sqmm . , b . control cable upto 24cx 2 . 5 sqmm .
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 977da6fc-07db-4077-91a3-69341f682257
Download File Name File Description
Download Tendernotice_1 Tender Documents - Tender Document
Download 712DC8A6-B93A-4819-8712-7FEF13E984B8 Tender Documents - Tender Notice
Download BOQ_566439 Tender Documents - Price Bid Format
Download 9660922_21456_12022020 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000