BRR : 2096973
Click Here To View Tendering Authority. Aoc City/State :  Bhopal, Madhya Pradesh
Tender Brief : Repair Of 33 / 11 Kv, 2 Mva Transformer At 33 Kv Mrs Dronachal, Bhopal , Disconnecting All Eletrical Connections From Transformer And Dismantling The Components Of Transformer For Easy Loading Transportation Unloading The Unserviceable Transfomer 2 Mva, 33 / 11 Kv Copper Wound From 33 Kv Mrs Dronachal Area To Workshop And Back Including Installation, Testing And Commissioning After Repairs Including Painting Of Complete Transfomer And Its Mounting Structure Complete All As Specified And As Directed. Make: Areva, Sr No. / Makers No. Of Transformer - Tnlk-2928 / D6638, Mes No:6763329Tr0... Read More
Tender Value
6,84,900
Contract Value
₹ 6,19,497.5
Saving / Difference
₹ 65,403 ▲
Submission Date
05-12-2022
Contract Date
02-01-2023
Completion Date
60 days
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 6,66,750 L3
2 cnet-technologies Bid Analytics 6,24,175 L2
3 cnet-technologies Bid Analytics 6,84,768 L1
Work Detail
repair of 33 / 11 kv, 2 mva transformer at 33 kv mrs dronachal, bhopal , disconnecting all eletrical connections from transformer and dismantling the components of transformer for easy loading transportation unloading the unserviceable transfomer 2 mva, 33 / 11 kv copper wound from 33 kv mrs dronachal area to workshop and back including installation, testing and commissioning after repairs including painting of complete transfomer and its mounting structure complete all as specified and as directed. make: areva, sr no. / makers no. of transformer - tnlk-2928 / d6638, mes no:6763329tr07. , labour only for opening the top cover of transformer and carrying out the following work / repairs by specialist / reputed transformer manufacturer or repairing firm:- ( a ) removing of transformer oil from transformer into separate barrels. ( b ) taking out the core assembly with hv & lv windings of the transformer. ( c ) cleaning the transformer from inside of tank as per manufacturers guidleines and painting with one coat of zinc paint as per manufacturers norms. ( d ) ovening in vapour phase drying oven at factory workshop for 72 hrs. ( e ) decoiling of old hv & lv copper windings retrived from core assembly and providing the new paper insulation over the old copper wire. ( f ) filling of new transformer oil complete with quantity 1485 ltrs approx. ( g ) reassembling of winding over the core of the transformer. ( h ) replacement of bushings, spindle, oil levelindicator, winding temperature gauge, oil temperature gauge, drain valve, breather etc. ( j ) refixing of transformer top cover with new gasket, nut-bolts etc complete. ( k ) testing and repair of radiator complete against any type of leakage and carry out soldering / brazing if required to stop the leakage. note:- ( i ) transformer oil, hv and lv windings shall be measured and paid separately. ( ii ) routine test, high voltage test, buchholtz relay tripping test and all other mandatory tests shall be carried out in the presence of rep nominated by hq cwe bhopal at factory premises. ( iii ) the quoted rate are inclusive of all minor spare parts that are required to make function electrically to transformewr and not mentioned in sch a boq. ( iv ) the repair work shall have guarantee of 18 months. , m & l for re-winding of hv ( 18 nos of coils ) and lv ( 3 nos of coils ) windings with old copper wire by providing new tripple paper cover ( tpc ) as per is insulation over the old wire as per the old existing windings i.e. matching with the same number of turns including best quality insulation, varnishing by vaccum impregnation and baking of coil assembly to achieve designed di-electric strength voltage ratio, turn ratio as per manufacturers instructions complete including testing all as specified and directed. , m & l for re-winding of hv windings with new copper wire ( approx 3 kgs ) alongwith new tripple paper cover ( tpc ) as per is insulation as per the old existing windings i.e. matching with the same number of turns including best quality insulation, varnishing by vaccum impregnation and baking of coil assembly to achieve designed di-electric strength voltage ratio, turn ratio as per manufacturers instructions complete including testing all as specified and directed. , supply only transformer oil as per is : 12463 ( 1998 ) di-electric strength should be upto 60 kv breaking voltage complete all as specified & directed. make: transoil, power oil. , supply only of breather assembly with fresh filling of silica gel of adequate capacity in non metallic transparent enclosure for transformer capacity of 2 mva complete all as specified and as directed. => limited
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 35e5eb11-4c2d-43d6-98a0-243ba8ce4b51
Download 8489AOC63
Download AOC_Dronachal
Download boqcomparativechart
Download finance_632893
Download finsummary_632893
Download technical_632893
Download techsummary_632893
Download File Name File Description
Download fd9fc392-9763-4904-a40f-ab3c4cc81d6c Tender Documents
Download BOQ_632893 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000