Tender Brief : Repairs To 250 Kva Transformer At Adm Area At Mil Stn Dappar Under Ge ( P ) Dappar , ( A ) Taking Down Defective Distribution Transformer 11/0 . 433 Kv Capacity 250 Kva From 2 Pole Structure / 4 Pole Structure / Plinth Mounted And Transportation To Workshop And Back After Carrying Out Necessary Repairs / Replacement Of Defective Parts And Refixing , Including Installation , Commissioning Testing On Load As Specified . Opening Of Transformer Top Cover By Unscrewing Nuts , Bolts Etc And Keeping Aside And Getting Out Transformer Oil , Isolation Of Hv & Lv Winding From Tank And... Read More
Tender Value
₹
1,85,490
Contract Value
₹ 1,50,000
Saving / Difference
₹ 35,490
▲
Submission Date
17-08-2020
Contract Date
27-08-2020
Completion Date
60 days
Participated Bidder List
9 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 1,82,400 | L8 | |||
| 2 | cnet-technologies | Bid Analytics | 1,50,000 | L1 | |||
| 3 | cnet-technologies | Bid Analytics | 1,68,000 | L4 | |||
| 4 | cnet-technologies | Bid Analytics | 1,74,000 | L6 | |||
| 5 | cnet-technologies | Bid Analytics | 1,57,900 | L2 | |||
| 6 | cnet-technologies | Bid Analytics | 1,70,000 | L5 | |||
| 7 | cnet-technologies | Bid Analytics | 1,85,550 | L9 | |||
| 8 | cnet-technologies | Bid Analytics | 1,82,000 | L7 | |||
| 9 | cnet-technologies | Bid Analytics | 1,65,000 | L3 |
Work Detail
repairs to 250 kva transformer at adm area at mil stn dappar under ge ( p ) dappar , ( a ) taking down defective distribution transformer 11/0 . 433 kv capacity 250 kva from 2 pole structure / 4 pole structure / plinth mounted and transportation to workshop and back after carrying out necessary repairs / replacement of defective parts and refixing , including installation , commissioning testing on load as specified . opening of transformer top cover by unscrewing nuts , bolts etc and keeping aside and getting out transformer oil , isolation of hv & lv winding from tank and checking , testing by technical expert team , rewinding of 11 kv ht / lt side out of 11 / 0 . 433kv , distribution transformer with super enameled copper conductor as per existing size and gauge with providing f class insulating materials and carrying out varnishing , drying by electric furnace . note : ht/lt coil for rewinding of transformer shall be measured seperately in respective item . each -01 job . ( b ) removing the burnt out ht winding coils and rewinding with braided copper conductor as that if existing gauge and no of turns all as specified and directed . kgs-100 ( c ) removing the burnt out lt winding coils and rewinding with braided copper conductor as that existing gauge and no of turns including insulating with all as specified and directed . -kgs 20 ( d ) replacement of silica gel breather -01 no ( e ) replacement of temperature gauge -01 no ( f ) removing the burnt out lv bushes and replace with brass lv bushes , nuts , check nuts etc complete for transformer of capacity 250 kva each -04 ( g ) removing the burnt out hv bushes and replace with brass hv bushes , nuts , check nuts etc complete for transformer of capacity 250 kva each -03 ( h ) replacement of synthethetic rubberised cork sheet gasket 1/4 thick suitable for main body of transforemr capacity 250 kva . -each -07 ( j ) replacement of on off ht tap changer of suitable size with tapping arrangement 2 . 5% to 3 . 5% capacity 250 kva transformer . -each -01 ( k ) material and labour transformer oil low viscoscitiy ehv grade having 60 kv di-electric strength conforming to is-335 in orginal company sealed drum for replacement or topping up to oil level mark at the conservator all as specified and directed by engr-in-charge . ltrs -120 ( l ) dehumidification and filteration of transformer oil at different locations by dehumidification plant including testing of oil samples both before and after filteration all as specified and as directed by engr-in-charge . -ltrs -330note : the dielectric strength of the transformer oil shall be not less than 40 kva with 2mm gap after filtration . ( m ) m&l for painting of transformer 250 kva with good quality synthetic enamel paint by spraying two coats on external portion of transformenr after scrubbing cleaning stains greasy spots dust , including cleaning of tempreature gauge and silica gel , oil tempreature level . the painting of transformer shall be carried out including writing of sm/mes no by approved white enamel paint complete each 01 jobnote : old unserviceable materials would be contractor property
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 40f36b74-27a4-4c7b-bdf5-7702c6873b2d |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000
Similar Tenders Results