BRR : 1907649
Click Here To View Tendering Authority. Aoc City/State :  GE (AF) LOHEGAON, Maharashtra
Tender Brief : Outsourcing Of Services For Manning And Operation Of Central Package Type Ac Plant At South Side Runway Under Age Em Af Lohegaon At Af Stn Pune , Outsourcing Of Services For Operation Of Central/Package Type Ac Plants For Maintaining The Specified Temperature And Humidity By Operating The Ac Plants & Its Control , Electric Panel , Condenser & Chiller Pump Sets , Cooling Tower , Ahus , Humudifire & Dehumidifire , Heater Banks , Control Sluice /Butterfly Valves Etc Including Taking And Recording Roomwise Temperature , Humudity In Log Sheet Hourly , Keeping The Plant In Presentabl... Read More
Tender Value
36,96,000
Contract Value
₹ 24,58,500
Saving / Difference
₹ 12,37,500 ▲
Submission Date
12-05-2020
Contract Date
06-06-2020
Completion Date
300 days
Participated Bidder List
7 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 35,14,500 L7
2 cnet-technologies Bid Analytics 29,86,500 L3
3 cnet-technologies Bid Analytics 34,58,400 L5
4 cnet-technologies Bid Analytics 34,65,000 L6
5 cnet-technologies Bid Analytics 26,69,700 L2
6 cnet-technologies Bid Analytics 24,58,500 L1
7 cnet-technologies Bid Analytics 32,96,700 L4
Work Detail
outsourcing of services for manning and operation of central package type ac plant at south side runway under age em af lohegaon at af stn pune , outsourcing of services for operation of central/package type ac plants for maintaining the specified temperature and humidity by operating the ac plants & its control , electric panel , condenser & chiller pump sets , cooling tower , ahus , humudifire & dehumidifire , heater banks , control sluice /butterfly valves etc including taking and recording roomwise temperature , humudity in log sheet hourly , keeping the plant in presentable condition by daily cleaning of machinery , panels , inside and outside area of plant room , cleaning of cooling tower & filter of ahus forthnightly etc by deploying one skilled refrigeration mechanic per shift ( 8 hrs shift ) for the following ac plants in two shift per day including sunday & holiday complete all as specified and directed- first shift - 0600 hrs to 1400 hrssecond shift - 1400 hrs to 2200 hrs , ( i ) central water cooled chiller ac plants of capacity 85 tr ( 1x 85 tr running and 1 x 85tr standby ) , 3x condenser pump set , 3x choller pump sets . 1x cooling tower , 1x ahu etc at ssc ( ii ) central ac plants dx type of capacity 26tr ( 2x13 tr running & 1 x 13 tr standby ) , 3x condenser pump set , 1x cooling tower , 1x ahu etc at kts-4 ( iii ) central package air cooled type ac plant of cap 34tr ( 2x17 tr running & 1x17 tr standby ) , etc at p-744 , out sourcing of services for operation of central/package type ac plants for maintaining the specified temperature and humidity by operating the ac plants & its control , electric panel , condenser & chiller pump sets , cooling tower , ahus , humudifire & dehumidifire , heater banks , control sluice /butterfly valves etc including taking and recording roomwise temperature , humudity in log sheet hourly , keeping the plant in presentable condition by daily cleaning of machinery , panels , inside and outside area of plant room , cleaning of cooling tower & filter of ahus forthnightly etc by deploying one skilled refrigration mechanic per shift ( 8 hrs shift ) for the following ac plants round the clock in three shift per day including sunday & holiday complete all as specified and directed:- first shift - 0600 hrs to 1400 hrssecond shift - 1400 hrs to 2200 hrs third shift - 2200 hrs to 0600 hrs , central ac plant water cooled chiller type of capacity 200 tr ( 2x100 tr running & 1x100 tr standby ) 3x chiller pump sets , 3x condenser pump sets , 1xcooling tower , 4x ahus at separate db of dwsa , ( i ) central ac plant chiller water cooled type s of capacity 48tr ( 2x24 tr running & 1x24 tr standby ) , 3x condenser pump set , 3x chiller pump set , 1x cooling tower , 3x ahu etc at ptt bldg ( ii ) central ac plant chiller water cooled type of capacity 72 tr ( 2x36 tr running & 1x36 tr standby ) , 3x condenser pump set , 3x chiller pump set , 1x cooling tower , 3x ahus etc at simulator bldg . , central ac plant chiller air cooled type of capacity 150 tr ( 2x75 tr running & 1x75 tr standby ) 2x chiller pump sets , 2x hot water generator pump sets , 1x hot water generator , 3x ahus at separate db with humudifire pump sets at akash 2402 sqn , note :- for srl item no 1 . 00 to 2 . 03 ( i ) contractor shall submit the nominal roll and qualification certificate of operator with in 15 days of acceptance . ( ii ) the operator shall be iti qualified in refrigeration or shall have minimum 05 years experience in operation of central ac plants . ( iii ) contractor shall ensure attendance of all operators shift wise if any operator found absent from duty a recovery of double the rate quoted by the contractor against each shift/item shall be made . ( iv ) all necessary t&p including uniform shall be provided by the contractor to the operators at no extra cost . the rates for the same is deemed to be included in the unit rates of the items . ( v ) the contractor shall provide of all the necessary stationery such as log book , attendance register etc to the operator for maintenance the plant running record . ( vi ) all operator shall wear proper uniform on duty . ( vii ) contractor have to submit the payment proof in aadhar linked accouts of operators account at the time of submission of rar . ( viii ) contractor shall provide notice board of each installation with in 15 days from the date of commencement of contract . ( ix ) area cleaning including cutting of grasses etc up to 3 meters from the plinth protection all around plant room and cooling tower ( x ) contractor shall submit the monthly duty roster of each installation before 03 days of respective month . ( xi ) suitable reliever to be provided during off shift operator as per the labour law . ( xii ) if the quoted amount is less than the estimated cost of the work , then the lowest bidder will have to deposit fdr/bgb in favour of accepting officer within 07 days of opening of financial bid for the difference in estimated cost & quoted amount . in case the said fdr/bgb is not submitted within the stipulated period as mentioned above , the contractor shall be banned for 06 months & his bid will be rejected . fdr/bgb shall be released only after satisfactory completion of work including defect liability period of contract whenever applicable . ( xiii ) the minimum wages are revised every six months , therefore the rates quoted shall be applicable as on bid submission end date and the bidder shall undertake to pay only as per minimum wages revised from time to time in future during the contract period and the contractor shall have no claim whatsoever on this account .
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 3163165f-3b97-43e1-879a-7159b01f4ed9
Download File Name File Description
Download Tendernotice_1 Tender Documents - NIT
Download E702D89D-ED77-4EE5-9E55-F169BF3DCB36 Tender Documents - Tender Notice
Download 8355COMMONPAGES Tender Documents - 8355COMMONPAGES
Download 8355PS Tender Documents - 8355PS
Download BOQ_380808 Tender Documents - 8355BOQ
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000