BRR : 1863774
Click Here To View Tendering Authority. Aoc City/State :  dalhousie, Himachal Pradesh
Tender Brief : Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Jsv, Lwsst / Well At Minjgran By Prov. 11 / .4 Kv 63 Kva S / Stn.A / W 11 Kv Ht Section Nurpur Under Esd Nurpur Ed Nurpur ( T.S. No. 102 / 22-23 ) ( Ii ) Tender For Supply Of Equipment / Material , Design, Erection, Testing & Commissioning For Sop To Lwss Chhatroli By Prov. 11 / .4 Kv 63 Kva S / Stn. At Chhatroli ( Batu-Ka-Nalah ) A / W 11 Kv Htlinesection Jassure Under Esd Nurpur Ed Nurpur ( T.S. No. 101 / 22-23 ) --- 1 Supply Part Of 11 / .... Read More
Tender Value
11,28,027
Contract Value
₹ 9,38,519
Saving / Difference
₹ 1,89,508 ▲
Submission Date
27-03-2023
Contract Date
25-04-2023
Completion Date
120 days
Participated Bidder List
8 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 9,70,103.89 L4
2 cnet-technologies Bid Analytics 9,64,350.95 L3
3 cnet-technologies Bid Analytics 9,63,335.72 L2
4 cnet-technologies Bid Analytics 9,38,519 L1
5 cnet-technologies Bid Analytics 10,36,770.33 L5
6 cnet-technologies Bid Analytics
7 cnet-technologies Bid Analytics 11,39,420.86 L6
8 cnet-technologies Bid Analytics
Work Detail
supply of equipment / material , design, erection, testing & commissioning for sop to jsv, lwsst / well at minjgran by prov. 11 / .4 kv 63 kva s / stn.a / w 11 kv ht section nurpur under esd nurpur ed nurpur ( t.s. no. 102 / 22-23 ) ( ii ) tender for supply of equipment / material , design, erection, testing & commissioning for sop to lwss chhatroli by prov. 11 / .4 kv 63 kva s / stn. at chhatroli ( batu-ka-nalah ) a / w 11 kv htlinesection jassure under esd nurpur ed nurpur ( t.s. no. 101 / 22-23 ) --- 1 supply part of 11 / .4 kv 63 kva distribution sub station 2 11 / .4 kv 63kva dtr ( rec sep. ord 11 / 1976 3 prov. st polepole 9 mtr. long w / l 200 kgs 4 muff for steel tubular pole with concrete filling 5 x-arm: [ channel iron ( 100x50x5 mm ) , length : 2800 mm x 2 nos ] for incomer line 6 ms a.i. ( 50x50x6 mm ) , length: 2800 mm x ( 1 nos for las ) 7 x-arm: [ channel iron ( 75x40x5 mm ) , length : 2800 mm x 4 nos ] for supporting do fuse unit & go switch 8 x-arm: [ channel iron ( 100x50x6 mm ) , length : 2800 mm x 2 nos ] for transformer bed 9 x-arm [ channel iron ( 100x50x6 mm ) , length : 460 mm x 2 nos for supporting main channel of transformer ] 10 ms a.i. ( 50x50x6 mm ) , length: ( 2800 mm ) x 2 no. 11 ms angle iron ( 35x35x5 mm ) , length : 460 mm x 2 nos 12 ms a.i. ( 50x50x6 mm ) , length: ( 950 mm ) x 2 nos. of bed knee bracing 13 ms angle iron ( 50x50x6 mm ) , length : ( 2800 mm ) x2 nos for transformer lt distribution box and g.o switch fixing assembly 14 ms angle iron ( 50x50x6 mm ) , length : ( 450 mm ) x1 nos for transformer lt distribution box and g.o switch fixing assembly 15 g.o. switch handle supporting: [ c.i. ( 75x40x6mm ) , length: 460mm for transformer lt distribution box and g.o switch fixing assembly 16 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 17 d.o fuse unit 18 surge arrester, 9 kv station class 19 discs insulator sets ( comp. 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) i / c dead end clamps etc. ) 20 stay set complete 21 staywire ( 7 / 3.15mm ) ( 10 kg per stay set ) 22 pipe earthing with gi, charcoal & salt 23 prov. lt distribution panel with mccb ( 100 a, 10 ka, 4p, 1 no. ) & sfu ( 32 a 4 no. rewireble ) for 63kva trf. as per specification 24 half clamp ( m.s. flat 50x6 ) 25 full clamps ( m.s. flat 50x6 ) 26 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 27 aluminium thimbles 28 copper thimble 29 danger plate 30 barbed wire ( rec sp f 3 / 1981 ) 31 lt cable 3-1 / 2 core-95mm sq. 32 alluminium paint 33 prov.acsr, 6 / 1 / 3.35 mm 34 prov.63kva s / stn structure protection a / w chain link fencing, angle iron gate etc. for dtr fencing. 35 erection part of 11 / .4 kv 63 kva distribution sub station 36 11 / .4 kv 63kva dtr ( rec sep. ord 11 / 1976 37 prov. st polepole 9 mtr. long w / l 200 kgs 38 muff for steel tubular pole with concrete filling 39 x-arm: [ channel iron ( 100x50x5 mm ) , length : 2800 mm x 2 nos ] for incomer line 40 ms a.i. ( 50x50x6 mm ) , length: 2800 mm x ( 1 nos for las ) 41 x-arm: [ channel iron ( 75x40x5 mm ) , length : 2800 mm x 4 nos ] for supporting do fuse unit & go switch 42 x-arm: [ channel iron ( 100x50x6 mm ) , length : 2800 mm x 2 nos ] for transformer bed 43 x-arm [ channel iron ( 100x50x6 mm ) , length : 460 mm x 2 nos for supporting main channel of transformer ] 44 ms a.i. ( 50x50x6 mm ) , length: ( 2800 mm ) x 2 no. 45 ms angle iron ( 35x35x5 mm ) , length : 460 mm x 2 nos 46 ms a.i. ( 50x50x6 mm ) , length: ( 950 mm ) x 2 nos. of bed knee bracing 47 ms angle iron ( 50x50x6 mm ) , length : ( 2800 mm ) x2 nos for transformer lt distribution box and g.o switch fixing assembly 48 ms angle iron ( 50x50x6 mm ) , length : ( 450 mm ) x1 nos for transformer lt distribution box and g.o switch fixing assembly 49 g.o. switch handle supporting: [ c.i. ( 75x40x6mm ) , length: 460mm for transformer lt distribution box and g.o switch fixing assembly 50 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 51 d.o fuse unit 52 surge arrester, 9 kv station class 53 discs insulator sets ( comp. 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) i / c dead end clamps etc. ) 54 stay set complete 55 staywire ( 7 / 3.15mm ) ( 10 kg per stay set ) 56 pipe earthing with gi, charcoal & salt 57 prov. lt distribution panel with mccb ( 100 a, 10 ka, 4p, 1 no. ) & sfu ( 32 a 4 no. rewireble ) for 63kva trf. as per specification 58 half clamp ( m.s. flat 50x6 ) 59 full clamps ( m.s. flat 50x6 ) 60 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 61 aluminium thimbles 62 copper thimble 63 danger plate 64 barbed wire ( rec sp f 3 / 1981 ) 65 lt cable 3-1 / 2 core-95mm sq. 66 alluminium paint 67 prov.acsr, 6 / 1 / 3.35 mm 68 prov.63kva s / stn structure protection a / w chain link fencing, angle iron gate etc. for dtr fencing. 69 supply part of ht line with acsr 6 / 1 / 3.35 mm sq. on steel poles ( 0.190km ) 70 acsr 6 / 1 / 3.35 ( 55mm² ) { includes 3 conductor lengths for 3f and additional 1% ( sag, jumpering and wastage } 71 prov. steel tubular poles. 9mtrs 72 muff for steel tubular pole ( 2000mm long ) with concrete filling 73 cross arm: [ channel iron ( 100x50x6 mm ) , length 1270 mm ( i / c tolerence of 100mm either side ) x2 structure ( run through structure ( formation tringle ) 74 angle iron ( 50x50x5 mm ) , length ( 2x750 ) mm x 1 structures ( run through structure ( formation tringle ) 75 pole top bracket [ msci:100x50x6mm-100mm ] 76 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure ( run through structure ( formation tringle ) 77 belt set - ms angle iron: 50x50x6, length [ 1800 mm x 2 no. ] for dead end structures 78 x-bracing set - ms angle iron: 50x50x6, length [ 2125 mm x2 no. ] for dead end structures 79 x-arm ( horizental ) - ms c. iron: 50x50x6, length [ 2340 mm x2 no. ] for dead end structures 80 discs insulator sets on dead end structures ( comprising 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) including dead end clamps etc. ) x ( 3 no. conductors ) x ( 2 no. sides ) for dead end structures 81 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure for dead end structures 82 stay set complete in all respect ( single pole-1no. , / d. pole structures-4nos. ) 83 stay wire ( 7 / 3.15 mm ) ( 8.0 kg per stay set ) 84 ht earthing set complete ( rec constr. standared j-1 ) 85 single continous earth wire ( gi, 8 swg ) { alongwith 1 wire lengths for avg. one road crossing @ 20 m and additional 1% ( sag and wastage ) } @ 0.102 kg / m 86 eye hook for earth wire 87 earth wire clamp 88 ms chanel iron 75x40x6mm, length: 2400mm for road crossing / g.o switch 89 half clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 90 full clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 91 danger plate ( 250x200x1.6 mm ) 92 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 93 barbed wire ( rec sp f 3 / 1981 ) 94 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 95 alluminium paint 96 erection part of ht line with acsr 6 / 1 / 3.35 mm sq. on steel poles ( 0.190km ) 97 acsr 6 / 1 / 3.35 ( 55mm² ) { includes 3 conductor lengths for 3f and additional 1% ( sag, jumpering and wastage } 98 prov. steel tubular poles. 9mtrs 99 muff for steel tubular pole ( 2000mm long ) with concrete filling 100 cross arm: [ channel iron ( 100x50x6 mm ) , length 1270 mm ( i / c tolerence of 100mm either side ) x2 structure ( run through structure ( formation tringle ) 101 angle iron ( 50x50x5 mm ) , length ( 2x750 ) mm x 1 structures ( run through structure ( formation tringle ) 102 pole top bracket [ msci:100x50x6mm-100mm ] 103 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure ( run through structure ( formation tringle ) 104 belt set - ms angle iron: 50x50x6, length [ 1800 mm x 2 no. ] for dead end structures 105 x-bracing set - ms angle iron: 50x50x6, length [ 2125 mm x2 no. ] for dead end structures 106 x-arm ( horizental ) - ms c. iron: 50x50x6, length [ 2340 mm x2 no. ] for dead end structures 107 discs insulator sets on dead end structures ( comprising 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) including dead end clamps etc. ) x ( 3 no. conductors ) x ( 2 no. sides ) for dead end structures 108 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure for dead end structures 109 stay set complete in all respect ( single pole-1no. , / d. pole structures-4nos. ) 110 stay wire ( 7 / 3.15 mm ) ( 8.0 kg per stay set ) 111 ht earthing set complete ( rec constr. standared j-1 ) 112 single continous earth wire ( gi, 8 swg ) { alongwith 1 wire lengths for avg. one road crossing @ 20 m and additional 1% ( sag and wastage ) } @ 0.102 kg / m 113 eye hook for earth wire 114 earth wire clamp 115 ms chanel iron 75x40x6mm, length: 2400mm for road crossing / g.o switch 116 half clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 117 full clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 118 danger plate ( 250x200x1.6 mm ) 119 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 120 barbed wire ( rec sp f 3 / 1981 ) 121 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 122 alluminium paint 123 supply part of 11 / .4 kv 63 kva distribution sub station 124 11 / .4 kv 63kva dtr ( rec sep. ord 11 / 1976 125 prov. st polepole 10 mtr. long w / l 200 kgs 126 muff for steel tubular pole with concrete filling 127 x-arm: [ channel iron ( 100x50x5 mm ) , length : 2800 mm x 2 nos ] for incomer line 128 ms a.i. ( 50x50x6 mm ) , length: 2800 mm x ( 1 nos for las ) 129 x-arm: [ channel iron ( 75x40x5 mm ) , length : 2800 mm x 4 nos ] for supporting do fuse unit & go switch 130 x-arm: [ channel iron ( 100x50x6 mm ) , length : 2800 mm x 2 nos ] for transformer bed 131 x-arm [ channel iron ( 100x50x6 mm ) , length : 460 mm x 2 nos for supporting main channel of transformer ] 132 ms a.i. ( 50x50x6 mm ) , length: ( 2800 mm ) x 2 no. 133 ms angle iron ( 35x35x5 mm ) , length : 460 mm x 2 nos 134 ms a.i. ( 50x50x6 mm ) , length: ( 950 mm ) x 2 nos. of bed knee bracing 135 ms angle iron ( 50x50x6 mm ) , length : ( 2800 mm ) x2 nos for transformer lt distribution box and g.o switch fixing assembly 136 ms angle iron ( 50x50x6 mm ) , length : ( 450 mm ) x1 nos for transformer lt distribution box and g.o switch fixing assembly 137 g.o. switch handle supporting: [ c.i. ( 75x40x6mm ) , length: 460mm for transformer lt distribution box and g.o switch fixing assembly 138 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 139 d.o fuse unit 140 surge arrester, 9 kv station class 141 discs insulator sets ( comp. 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) i / c dead end clamps etc. ) 142 stay set complete 143 staywire ( 7 / 3.15mm ) ( 10 kg per stay set ) 144 pipe earthing with gi, charcoal & salt 145 prov. lt distribution panel with mccb ( 100 a, 12 ka, 4p, 1 no. ) & sfu ( 32 a 4 no. rewireble ) for 63 kva trf. as per specification 146 half clamp ( m.s. flat 50x6 ) 147 full clamps ( m.s. flat 50x6 ) 148 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 149 aluminium thimbles 150 copper thimble 151 danger plate 152 barbed wire ( rec sp f 3 / 1981 ) 153 lt cable 3-1 / 2 core-185mm sq. 154 alluminium paint 155 prov.acsr, 6 / 1 / 3.35 mm 156 prov.63kva s / stn structure protection a / w chain link fencing, angle iron gate etc. for dtr fencing. 157 erection part of 11 / .4 kv 63 kva distribution sub station 158 11 / .4 kv 63kva dtr ( rec sep. ord 11 / 1976 159 prov. st polepole 10 mtr. long w / l 200 kgs 160 muff for steel tubular pole with concrete filling 161 x-arm: [ channel iron ( 100x50x5 mm ) , length : 2800 mm x 2 nos ] for incomer line 162 ms a.i. ( 50x50x6 mm ) , length: 2800 mm x ( 1 nos for las ) 163 x-arm: [ channel iron ( 75x40x5 mm ) , length : 2800 mm x 4 nos ] for supporting do fuse unit & go switch 164 x-arm: [ channel iron ( 100x50x6 mm ) , length : 2800 mm x 2 nos ] for transformer bed 165 x-arm [ channel iron ( 100x50x6 mm ) , length : 460 mm x 2 nos for supporting main channel of transformer ] 166 ms a.i. ( 50x50x6 mm ) , length: ( 2800 mm ) x 2 no. 167 ms angle iron ( 35x35x5 mm ) , length : 460 mm x 2 nos 168 ms a.i. ( 50x50x6 mm ) , length: ( 950 mm ) x 2 nos. of bed knee bracing 169 ms angle iron ( 50x50x6 mm ) , length : ( 2800 mm ) x2 nos for transformer lt distribution box and g.o switch fixing assembly 170 ms angle iron ( 50x50x6 mm ) , length : ( 450 mm ) x1 nos for transformer lt distribution box and g.o switch fixing assembly 171 g.o. switch handle supporting: [ c.i. ( 75x40x6mm ) , length: 460mm for transformer lt distribution box and g.o switch fixing assembly 172 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 173 d.o fuse unit 174 surge arrester, 9 kv station class 175 discs insulator sets ( comp. 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) i / c dead end clamps etc. ) 176 stay set complete 177 staywire ( 7 / 3.15mm ) ( 10 kg per stay set ) 178 pipe earthing with gi, charcoal & salt 179 prov. lt distribution panel with mccb ( 100 a, 12 ka, 4p, 1 no. ) & sfu ( 32 a 4 no. rewireble ) for 63 kva trf. as per specification 180 half clamp ( m.s. flat 50x6 ) 181 full clamps ( m.s. flat 50x6 ) 182 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 183 aluminium thimbles 184 copper thimble 185 danger plate 186 barbed wire ( rec sp f 3 / 1981 ) 187 lt cable 3-1 / 2 core-185mm sq. 188 alluminium paint 189 prov.acsr, 6 / 1 / 3.35 mm 190 prov.63kva s / stn structure protection a / w chain link fencing, angle iron gate etc. for dtr fencing. 191 supply part of ht line with acsr 6 / 1 / 3.35 mm sq. on steel poles ( 0.230 km ) 192 acsr 6 / 1 / 3.35 ( 55mm² ) { includes 3 conductor lengths for 3f and additional 1% ( sag, jumpering and wastage } 193 prov. steel tubular poles. 9mtrs 194 muff for steel tubular pole ( 2000mm long ) with concrete filling 195 cross arm: [ channel iron ( 100x50x6 mm ) , length 1270 mm ( i / c tolerence of 100mm either side ) x2 structure ( run through structure ( formation tringle ) 196 angle iron ( 50x50x5 mm ) , length ( 2x750 ) mm x 1 structures ( run through structure ( formation tringle ) 197 pole top bracket [ msci:100x50x6mm-100mm ] 198 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure ( run through structure ( formation tringle ) 199 belt set - ms angle iron: 50x50x6, length [ 1800 mm x 2 no. ] for dead end structures 200 x-bracing set - ms angle iron: 50x50x6, length [ 2125 mm x2 no. ] for dead end structures 201 x-arm ( horizental ) - ms c. iron: 50x50x6, length [ 2340 mm x2 no. ] for dead end structures 202 discs insulator sets on dead end structures ( comprising 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) including dead end clamps etc. ) x ( 3 no. conductors ) x ( 2 no. sides ) for dead end structures 203 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure for dead end structures 204 stay set complete in all respect ( single pole-1no. , / d. pole structures-4nos. ) 205 stay wire ( 7 / 3.15 mm ) ( 9.0 kg per stay set ) 206 ht earthing set complete ( rec constr. standared j-1 ) 207 single continous earth wire ( gi, 8 swg ) { alongwith 1 wire lengths for avg. one road crossing @ 20 m and additional 1% ( sag and wastage ) } @ 0.102 kg / m 208 eye hook for earth wire 209 earth wire clamp 210 ms chanel iron 75x40x6mm, length: 2400mm for road crossing / g.o switch 211 half clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 212 full clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 213 danger plate ( 250x200x1.6 mm ) 214 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 215 barbed wire ( rec sp f 3 / 1981 ) 216 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 217 alluminium paint 218 erection part of ht line with acsr 6 / 1 / 3.35 mm sq. on steel poles ( 0.230 km ) 219 acsr 6 / 1 / 3.35 ( 55mm² ) { includes 3 conductor lengths for 3f and additional 1% ( sag, jumpering and wastage } 220 prov. steel tubular poles. 9mtrs 221 muff for steel tubular pole ( 2000mm long ) with concrete filling 222 cross arm: [ channel iron ( 100x50x6 mm ) , length 1270 mm ( i / c tolerence of 100mm either side ) x2 structure ( run through structure ( formation tringle ) 223 angle iron ( 50x50x5 mm ) , length ( 2x750 ) mm x 1 structures ( run through structure ( formation tringle ) 224 pole top bracket [ msci:100x50x6mm-100mm ] 225 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure ( run through structure ( formation tringle ) 226 belt set - ms angle iron: 50x50x6, length [ 1800 mm x 2 no. ] for dead end structures 227 x-bracing set - ms angle iron: 50x50x6, length [ 2125 mm x2 no. ] for dead end structures 228 x-arm ( horizental ) - ms c. iron: 50x50x6, length [ 2340 mm x2 no. ] for dead end structures 229 discs insulator sets on dead end structures ( comprising 1 no. disc: ^^ ( porcelain, bs, 12 kv, 90 kn ) including dead end clamps etc. ) x ( 3 no. conductors ) x ( 2 no. sides ) for dead end structures 230 11 kv pin insulators ( porcelain, 12 kv, 10 kn ) : 3 no per pole structure for dead end structures 231 stay set complete in all respect ( single pole-1no. , / d. pole structures-4nos. ) 232 stay wire ( 7 / 3.15 mm ) ( 9.0 kg per stay set ) 233 ht earthing set complete ( rec constr. standared j-1 ) 234 single continous earth wire ( gi, 8 swg ) { alongwith 1 wire lengths for avg. one road crossing @ 20 m and additional 1% ( sag and wastage ) } @ 0.102 kg / m 235 eye hook for earth wire 236 earth wire clamp 237 ms chanel iron 75x40x6mm, length: 2400mm for road crossing / g.o switch 238 half clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 239 full clamp ( on d / p dead end str:4nos; on run through str. 2nos. ) 240 danger plate ( 250x200x1.6 mm ) 241 m. s. nuts & bolts off sizes ( galvanised coated ) [ prefarably 16mm ø or more ( with flat and spring washer ) 242 barbed wire ( rec sp f 3 / 1981 ) 243 g.o ab switch unit ( 11kv, 400, 663ka ) tripple pole o / d type 244 alluminium paint
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 2a8fd79a-10a8-4ea3-b027-cc2bfd2b98a5
Download File Name File Description
Download efd9a782-1403-4730-8229-0e55fda62a5f Tender Documents
Download Biddoc55 Tender Documents
Download BOQ_107379 Tender Documents
Download Tendernotice_1 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount : ₹ 1,00,00,000
Similar Tenders Results
TenderDetail
Loading tenders