BRR : 1637124
Tender Brief : Repair And Maintenance Of E And M Installations At Silchar Airport . Sh-Job Contract For E And M Installations At Terminal Building , Operational Area And Allied Works For The Year 2020-22 , Providing Maintenance Services And Operation Of Electrical & Mechanical Installations I . E Power Supply System , Electrical Installation Of Terminal Building , Fire Alarm & Fire Fighting , Attending Faults / Breakdowns Rectifications , Ensuring Serviceability / Satifactory Working Condition Of The Systems , Preventive Maintenance On Daily/ Weekly/ Monthly/ Quarterly/ Half Yearly/Yearly Basis ... Read More
Tender Value
₹
Ref. Document
Contract Value
₹ 68,87,264
Submission Date
01-07-2020
Contract Date
01-08-2020
Completion Date
730 days
Participated Bidder List
6 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | 69,35,700 | L2 | |||
| 2 | cnet-technologies | Bid Analytics | |||||
| 3 | cnet-technologies | Bid Analytics | 74,16,300 | L4 | |||
| 4 | cnet-technologies | Bid Analytics | 89,74,688 | L5 | |||
| 5 | cnet-technologies | Bid Analytics | 74,00,620 | L3 | |||
| 6 | cnet-technologies | Bid Analytics | 68,87,264 | L1 |
Work Detail
repair and maintenance of e and m installations at silchar airport . sh-job contract for e and m installations at terminal building , operational area and allied works for the year 2020-22 , providing maintenance services and operation of electrical & mechanical installations i . e power supply system , electrical installation of terminal building , fire alarm & fire fighting , attending faults / breakdowns rectifications , ensuring serviceability / satifactory working condition of the systems , preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis , maintenance of records/documentation etc . as per scope of work given in special conditions of contract shall be ensured round the clock ( ie . in two shifts basis , each shift of 8 hours ) on all days including sundays & national holidays as per direction of eic . for 1st year , providing maintenance services and operation of electrical & mechanical installations i . e power supply system , electrical installation of terminal building , fire alarm & fire fighting , attending faults / breakdowns rectifications , ensuring serviceability / satifactory working condition of the systems , preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis , maintenance of records/documentation etc . as per scope of work given in special conditions of contract shall be ensured round the clock ( ie . in two shifts basis , each shift of 8 hours ) on all days including sundays & national holidays as per direction of eic . for 2nd year , providing maintenance services and operation of glf systems at operational area ( comprising of hirl/ mirl / sapl / inset fittings , papi units , afl cables etc . ) attending faults / breakdowns rectifications , ensuring serviceability / satifactory working condition of the systems , preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis , maintenance of records/documentation etc . as per scope of work given in special conditions of contract shall be ensured round the clock on all days including sundays & national holidays as per direction of eic . for 1st year , providing maintenance services and operation of glf systems at operational area ( comprising of hirl/ mirl / sapl / inset fittings , papi units , afl cables etc . ) attending faults / breakdowns rectifications , ensuring serviceability / satifactory working condition of the systems , preventive maintenance on daily/ weekly/ monthly/ quarterly/ half yearly/yearly basis , maintenance of records/documentation etc . as per scope of work given in special conditions of contract shall be ensured round the clock on all days including sundays & national holidays as per direction of eic . for 2nd year , providing of services for preperation various reports , maintaining the records , preparation of rate analysis , estimates , tender documents etc along with various day to day office works as per scope of work given in special conditions of contract on all days excluding sundays and national holidays & as per direction of eic . for 1st year , providing of services for preperation various reports , maintaining the records , preparation of rate analysis , estimates , tender documents etc along with various day to day office works as per scope of work given in special conditions of contract on all days excluding sundays and national holidays & as per direction of eic . for 2nd year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . a ) services of high skilled personfor 1st year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . a ) services of high skilled personfor 2nd year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . a ) services of skilled personfor 1st year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . a ) services of skilled personfor 2nd year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . a ) services of semi skilled personfor 1st year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . a ) services of semi skilled personfor 2nd year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . b ) service of unskilled personfor 1st year , extra hours running & operation of electrical installations of airport due to exigencies/early or over watch hour extension beyond normal shift hours or as per specification . b ) service of unskilled personfor 2nd year , complete overhuling & repairing of 3 . 5 hp capacity water pump i/c replacement of defective keys , necessary lathe work , replacement of ball bearing & gland packing including replacement of bush bearing , replacement of minor hardware items and painting after dismantling from the existing location , transporation upto the workshop if necessary & reinstallation of the same , testing etc complete as required as per site condition . location: overhead refining for cft at apron area , complete overhuling & repairing of 5 hp capacity water pump i/c replacement of defective keys , necessary lathe work , replacement of ball bearing & gland packing including replacement of bush bearing , replacement of minor hardware items and painting after dismantling from the existing location , transporation upto the workshop if necessary & reinstallation of the same , testing etc complete as required as per site condition . location: fire pump room , complete overhuling & repairing of 7 . 5 hp capacity water pump i/c replacement of defective keys , necessary lathe work , replacement of ball bearing & gland packing including replacement of bush bearing , replacement of minor hardware items and painting after dismantling from the existing location , transporation upto the workshop if necessary & reinstallation of the same , testing etc complete as required as per site condition . location: water treatment plant , complete re-winding of burnt out stator coils of 3 ph . 20 hp induction motor along with removal of the burnt out copper coil/wire and providing new super anamel coated copper with insulation and varnishing with suitable quality of varnish and replacement of minor wornout hardware items etc . as required i/c giving less credit for the burnt out copper coil . location: overhead tank fire pump room , complete re-winding of burnt out stator coils of 3 ph . 50 hp induction motor along with removal of the burnt out copper coil/wire and providing new super anamel coated copper with insulation and varnishing with suitable quality of varnish and replacement of minor wornout hardware items etc . as required i/c giving less credit for the burnt out copper coil . location: fire pump room , complete re-winding of burnt out stator coils of 3 ph . 1 . 5 hp induction motor along with removal of the burnt out copper coil/wire and providing new super anamel coated copper with insulation and varnishing with suitable quality of varnish and replacement of minor wornout hardware items etc . as required i/c giving less credit for the burnt out copper coil . location: highmast , complete re-winding of burnt out stator
View Original Notice/Document
Result Documents
Tender Documents
| Download | File Name | File Description |
|---|---|---|
| Download | 34f43bfc-3e9a-4ebd-86e7-6645405a8c4b |
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
✦ ✦ ✦
Awarded Bidder(s)
1
cnet-technologies
Rank : L1 (Lowest)
Bid Amount :
₹
1,00,00,000