BRR : 10213848
Click Here To View Tendering Authority. Price Bid City/State :  rampur, Uttar Pradesh
Tender Brief : Tender For Releasing New Connection / Shifting Of Lines / Increasing Capacity Etc. Under Deposit Scheme In Future For The Period 01-10-2023 To 30-09-2024 Jurisdiction Of Edd-I, Rampur.- 1 Safe Carriage Of Following Material From Store Centre To Site / Je Store With Loading & Unloading At Both Ends Respectively Distance With In 60 Kms. 2 Pcc Pole 8.5 Mtr. Long 3 Pcc Pole 9 Mtr. Long 4 S.T. Pole 11 Mtr. Long 5 S.T. Pole 13 Mtr. Long 6 11 Kv Ct / Pt Unit 7 11 Kv Pilfer Proof Metering Cubical 8 11 / 0.4 Kv 25 Kva T / F 9 11 / 0.4 Kv 63 Kva T / F 10 11 / 0.4 Kv 100 Kv... Read More
Tender Value
5,00,000
Submission Date
29-09-2023
Participated Bidder List
3 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 1,31,876 L2
2 cnet-technologies Bid Analytics 1,22,171 L1
3 cnet-technologies Bid Analytics 1,32,276 L3
Work Detail
tender for releasing new connection / shifting of lines / increasing capacity etc. under deposit scheme in future for the period 01-10-2023 to 30-09-2024 jurisdiction of edd-i, rampur.- 1 safe carriage of following material from store centre to site / je store with loading & unloading at both ends respectively distance with in 60 kms. 2 pcc pole 8.5 mtr. long 3 pcc pole 9 mtr. long 4 s.t. pole 11 mtr. long 5 s.t. pole 13 mtr. long 6 11 kv ct / pt unit 7 11 kv pilfer proof metering cubical 8 11 / 0.4 kv 25 kva t / f 9 11 / 0.4 kv 63 kva t / f 10 11 / 0.4 kv 100 kva t / f 11 33 kv line isolater 12 11 kv tpmo 13 loading & safe carriage & unloading of heavy other line material ( other than pole ) such as acsr weasal / dog conductor, m.s. angle, m.s. channel, stay rod, earthing rod, 11 kv cable, l.t. cableetc. from store centre to site / je store distance with in 60 kms. and back cartage of material if required. 14 the excavation of foundation pit in mix. soil / normal soil / soft & hard rock and its back filling and leveling etc. the size of the pit will be ( 750 x 450 ) mm and having depth of 1 / 6th of the full length of the support, erection of support complete with providing & fixing of all clamps and other accessories as per drawing. the work includes carriage and handling ofsupports from sectional store to pit site as well as and fabrication work if required. ( single pole ) 15 pcc pole 8.5 mtr. long 16 pcc pole 9 mtr. long 17 s.t. pole 11 mtr. long 18 s.t. pole 13 mtr. long 19 the excavation of foundation pit in mix. soil / normal soil / soft & hard rock and its back filling and leveling etc. the size of the pit will be ( 750 x 450 ) mm and having depth of 1 / 6th of the full length of the support, erection of support complete with providing & fixing of all clamps and other accessories as per drawing. the work includes carriage and handling of supports from sectional store to pit size as well as and fabrication work if required & fixing of cross bracing sets 2.5 mtr. from m.s. angle 50x50x6 mm. the work includes cutting holes and providing m.s. bolt of 16x40 mm. size in the middle of the cross bracing with 01 no. spring washer of proper size as per drawing. ( doube pole structure ) 20 pcc pole 8.5 mtr. long 21 pcc pole 9 mtr. long 22 s.t. pole 11 mtr. long 23 s.t. pole 13 mtr. long 24 grouting of supports in cc 1:4:8 ( cement, sand & 40 mm brick ballast ) . grouting will be done in the block of size ( 450x450 ) mm x 1 / 6th of full length of the support up to ground level, 300 mm plinth, above the ground level with cc 1:3:6 ( cement, coarse sand & stone grit ) with muffing as per drawing. work includes back filling and proper ramming. ( i ) single pole 25 pcc pole 8.5 mtr. long 26 pcc pole 9 mtr. long 27 s.t. pole 11 mtr. long 28 s.t. pole 13 mtr. long 29 ( ii ) double pole 30 pcc pole 8.5 mtr. long 31 pcc pole 9 mtr. long 32 s.t. pole 11 mtr. long 33 s.t. pole 13 mtr. long 34 grouting of stay rods ( 16x1800 ) mm. including all work of excavation, cement, concreting in size ( 0.60x0.60x0.30 ) m in ratio 1:4:8 cement, sand, 40 mm brick ballast as per drawing, including backfilling of soil and proper ramming etc. 35 fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of stay insulators of 11 kvand stay clamps. 36 earthing of supports with m.s. earth rod of ( 20x2500 ) mm long including excavation of pit and driving m.s. rod 3-0 m apart from support and 0.5 m below the ground level and connecting below the earth electrodes with the help of g.i. wire no. 8 swg and earthing lugs. 37 laying, spreading, lifting and final sagging of 3 phases of acsr weasal conductor in accordance with line chart including binding and fixing of all accessories in conductor conductor in parallel in 11 kv / l.t. line. 38 laying, spreading, lifting and final sagging of 3 phases of acsr dog / rabbit conductor in accordance with line chart including binding and fixing of all accessories in 03 nos. conductor in parallel. 39 guarding between two poles single poles, double poles etc. to guard l.t. line, telephone and river crossing, road crossing etc. with g.i. wire no. 6 & 10 swg. 40 removal of old existing transformers from double pole / plinth after dismantling h.t. & l.t. connections along with back cartage from work site to store centre includng loading & unloading at both ends distance with in 60 kms. 41 11 / 0.4 kv 25 kva t / f 42 11 / 0.4 kv 63 kva t / f 43 11 / 0.4 kv 100 kva t / f 44 11 / 0.4 kv 250 kva t / f 45 11 / 0.4 kv 400 kva t / f 46 mounting of following transformers of different capacities, on double pole / plinth alongwith fixing of clamps and nuts & bolts with proper binding / jumpering etc. 47 11 / 0.4 kv 25 kva t / f 48 11 / 0.4 kv 63 kva t / f 49 11 / 0.4 kv 100 kva t / f 50 11 / 0.4 kv 250 kva t / f 51 11 / 0.4 kv 400 kva t / f 52 safely laying of 11 kv ab cable size of cable 3x50 sq. mm. 53 safely laying of 11 kv ab cable size of cable 3x95 sq. mm. 54 safely laying of 11 kv ab cable size of cable 3x120 sq. mm. 55 safely laying of 11 kvcable size of cable 3x120 sq. mm. 56 safely laying of 11 kv cable size of cable 3x150 sq. mm. 57 safely laying of 11 kv cable size of cable 3x185 sq. mm. 58 laying of underground 11 kv cable ( 3x35 / 3x70 / 3x150 / 3x185 ) after digging of trench including cost of sand & brick complete in all respect. 59 dismantling of old ct / pt unit from d / p. 60 mounting of ct / pt unit on double pole. 61 dismantling of old metering cubical. 62 mounting the metering cubical on foundation & grouting with rag bolts. 63 mounting the 11 kv tpmo 64 installation of 33 kv line isolater ( in yard ) 65 filling & fixing of 11 kv cable jointing kit 66 filling & fixing of 33 kv cable jointing kit 67 fixing of g.i. pipe 6 dia on double pole with providing & fixing clamps and bolts & nuts complete in all respect. 68 back cartage of dismantled ct / pt unit from work site to store centre rampur with loading & unloading at both ends distance with in 60 kms. 69 back cartage of dismantled metering cubical from work site to store centre rampur with loading & unloading at both ends distance with in 60 kms. 70 providing & fixing of danger board at each location as per specification of the drawing. 71 wrapping of barbed wire on 11 kv sp-55 s.t. poles / 8.5 mtr. pcc poles, as anti climbing device for a length of 0.9 mtr. wire pitch / gap 13 mm. and fixing upper and lower end keeping, lower end at a height of 2.75 mtr. from the ground complete with providing and fixing of lower end & upper end clamps made of m.s. flat 40x5 mm. complete with nuts & bolts. 72 dismantling of old existing supports with all accessories for shifting of line complete in all respect. ( single pole. ) 73 pcc pole 8.5 mtr. long 74 pcc pole 9 mtr. long 75 s.t. pole 11 mtr. long 76 s.t. pole 13 mtr. long 77 double pole structure 78 pcc pole 8.5 mtr. long 79 pcc pole 9 mtr. long 80 s.t. pole 11 mtr. long 81 s.t. pole 13 mtr. long 82 fixing of x-arm of 11 kv line with nuts & bolts & washers as per respo norms complete in all respect. ( provided by department for shifting of line ) 83 construction of plinth for 250 kva transformer 2x2x1.5 m with fencing as per respo norms and as per direction of supervising engineer ( material for plint and fencing will be provide by the contractor ) 84 fixing of insulators ( provided by department ) : 85 11 kv pin insulator with pin 86 11 kv disc insulator with fitting 87 painting of pole 88 s.t. pole 11 mtr. long 89 s.t. pole 13 mtr. long 90 providing & fixing of insulators & clamps: 91 clamp for t-off with bolts & nuts 92 clamp for d / p ( top, dropper etc. ) with bolts & nuts 93 guarding / x-arm holding clamp with bolts & nuts 94 f-bracket with bolts & nuts 95 e-bracket with bolts & nuts 96 p.g. clamp for weasal conductor 97 p.g. clamp for dog conductor 98 l.t. shackle insulator with bolts & nuts 99 l.t. clamp with bolts & nuts 100 g.i. pipe 6 dia 101 stay insulator with bolts & nuts 102 stay clamp with bolts & nuts 103 pvc lt seprator. 104 red oxide paint with painting 105 aluminium paint withh painting
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 5ade5a92-b167-4968-b9ba-fc78a4fd7108 financialevaluation notice
Download boqcomparativechart boq document
Download finsummary_1406458 aoc document
Download File Name File Description
Download 2751644c-8491-40f4-aa6b-739a5312cc08 Tender Documents
Download BOQ_1406458 Tender Documents
Download Tendernotice_1 Tender Documents
Download Tendernotice_2 Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders