BRR : 10201650
Click Here To View Tendering Authority. Price Bid City/State :  South Goa, Goa
Tender Brief : Defect Rectification On Various Hullequipment Onboard Icgs Samudra Prahari At Goa - Defect Rectificationon Various Hull Equipment Onboard Icgs Samudra Prahari At Goa 2 H-1044:Sampling Cock Of Dispersant Tank Not Holding And Leaking At Ac Compartment. To Be Renewed As Per The Sample Along With Flanges. Dia-25 Mm, Mat Gm. 3 H-1131:Fire Fighting Arrangement On Both Boats Had Lived Its Fair Life.Both Co2 Cylinders To Be Renewed Along With Its Operating Mechanism And Proved.Cylinder Cap- 09 Ltr 4 H-1152Captain’S Bath Shower Cubicle Sliding Door Uprooted From Channels. 08 No Sliding Wheels ... Read More
Tender Value
Ref. Document
Submission Date
18-05-2022
Participated Bidder List
4 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics 13,00,950 L2
2 cnet-technologies Bid Analytics 14,18,550 L3
3 cnet-technologies Bid Analytics 17,23,575 L4
4 cnet-technologies Bid Analytics 6,42,600 L1
Work Detail
defect rectification on various hullequipment onboard icgs samudra prahari at goa - defect rectificationon various hull equipment onboard icgs samudra prahari at goa 2 h-1044:sampling cock of dispersant tank not holding and leaking at ac compartment. to be renewed as per the sample along with flanges. dia-25 mm, mat gm. 3 h-1131:fire fighting arrangement on both boats had lived its fair life.both co2 cylinders to be renewed along with its operating mechanism and proved.cylinder cap- 09 ltr 4 h-1152captain’s bath shower cubicle sliding door uprooted from channels. 08 no sliding wheels to be renewed with holding bracket. mat- brass. concealed shower panel tower with shower head / hand shower and multi-function nozzle ( 06 nos ) to be renewed as per sample. mat- ss. top side panel cracked, to be renewed. mat – marine ply laminate with water proof coating. 5 h-1158:fresh water cu line of wash basin broken at q deck cu line ( dia 15 mm ) wall thick- 1.2 mm, to be renewed with stop cock / end fittings and helo deck fresh water line corrode / deteriorated to be renewed as per the sample mat- cu, length -6 mtrs including the securing of fresh water line brackets to be welded. fresh water lines of bath rooms / wc’s securing brackets uprooted / deteriorated to be renewed as per the sample.qty-20 nos. 6 h-1159:life raft stands deteriorated. to be renewed as per sample. qty -02 stands mat- ms, angle – 50x 50x 6 mm- 50 mtr, pipe dia- 65 mmx 10 mtr, sche-80 pipe dia -120 mm, 9 mtr. 7 h-1163:80 no u clamps with angle bracket for securing deluge pipes and fire main / hydraulic pipes at weather deck and q’ deck pilot entrance and exit door hinges corroded and perished. to be renewed as per sample. mat- u clamp ss-306, angle bracket- ms with rubber padding. job involves removal and refitment of insulation below bracket. material –ms-04 no’s 8 h-1179:water leakage on one no bridge widow glass to be renewed glass rubber beading and refitted asper sample. lxb -5x3.8 feet 9 h-1186;0 no’s fire man securing brackets rubber beading perished to be renewed as per the sample includes 03 no’s glass to be renewed as per the sample. 15 no’s fire extinguishers securing stands uprooted from the brackets to be repaired as per the sample and stbd side fire man securing buckets corroded to be renewed as per the sample. 10 h-1189:08 no’s pc boat ores decay to be fabricated as per the sample and securing arrangement to provide on pc boats and 02 no’s flag stanchions shoe and flag stanchions to be fabricated as per the sample. 11 h-1190:ship’s galley, sr sailor dining hall and jr sailor dining hall storage lockers hinges and locking arrangement uprooted from base. hinges to be renewed as per the sample and locker to be repaired. ( qty-10 no’s, mat hinges - ss, locker - ss 12 h-1191:08 in no’s awning supporting stanchions in bridge wing ( port and stbd ) corroded / deteriorated. to be renewed as per sample. awning to be stitched. mat stanchion -alawning size- 200cm x 130cm 13 h-1192:ship’s galley wash basin drain pipe corroded. to be repaired / renewed as per the sample. mat-ms, 14 h-1193;ship’s galley fcu drain pipe tray corroded. insulation, galley fresh water tap and non-return valve to be renewed as per the sample. drain pipe size - 1 / 2-inch and fuc pipe length - 1 mtr. 15 h-1199:ship’s office, regulating office, ops room, mso metallic drawers channels not working properly. to be repaired / renewal as per the sample. qty-25 no’s lockers
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 73c8f015-5258-4a92-9436-93aa256a8cb8 financialevaluation notice
Download boqcomparativechart boq document
Download finance_585007 aoc document
Download finsummary_585007 aoc document
Download File Name File Description
Download Tendernotice_1 Tender Documents
Download 11fe8b8f-711f-4727-9e3b-40b08e2df999 Tender Documents
Download BOQ_585007 Tender Documents
Download RFP Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders