View Bid Results For Proof Checking Tenders

We found 675 Bid Results related to proof checking tenders. You can find Contractor details who won proof checking tenders along with contract details in Bid awards announcements section.

Filters
Stage
476
117
82
Tender Publishing Platform
62
613
State / UT
33
93
80
65
55
54
37
35
27
23
23
22
20
19
18
15
14
13
9
9
7
6
5
4
4
4
3
3
2
2
1
1
1
1
Contract Value
242
102
268
62
Publish Date
2
0
0
0
0
Sector
27
241
78
58
39
39
33
26
26
25
25
14
12
11
7
6
6
6
4
4
3
3
2
2
2
1
1
1
Ownership
6
275
253
69
57
19
2
Within keyword
Active filters:
Showing 1–14 of 675 tenders matching your filters
1.
Defence #11478095 Technical Bid
Tender For Provision Of Certain Revenue And Minor Work At Age B/R Ii Under Ge(N) Patiala=- 1 Dismantling, Floor, Hearth Or Wall Tiling Including Cm (Bedding (But Not Backing), Removing Serviceable Tiles To Store & Rubbish Off The Premises Complete All As Specified And Directed 2 M&L For Single Charge, Vitrified, Stain & Scratch Resistant, Premium Quality Coloured Tiles Area Of Each Tiles Exceeding 0.42 Sqm But Not Exceeding 1.00 Sqm, In Floors Etc Mm And 8-10 Mm Thick, In Any Pattern Of Light & Dark Tiles As Approved, Laid Over 15 Mm Thick Screed In Cm (1:6) Epoxy Cartridge Tile Grout Using Filling The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour,Complete All As Specified And Directed. 3 All As Per Item No 2 Above But As In Skirting Over 10 Mm Thick Rendering In Cm 1:4 Complete All As Specified And Directed. 4 M&L For Ceramic Glossy Finish, Joint Free Premium Quality Coloured Tiles 600 X 300 Mm And 8-9 Mm Thick, In Any Pattern Of Light & Dark/Highlighters Tiles Etc As Approved, On Vertical Surfaces Such As In Skirting/Dado Etc, Set And Including 10 Mm Thick Rendering In Cement Mortar (1:4) And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 5 M & L For 15 Mm Thick Artificial Granite (Of Any Type) Work Steps, Jambs, Pillars, Window- Cills, Cooking Platforms And Like In Cement Mortar (1:4) Including Pointing In White Cement (1:2) Using Marble Dust With Admixture Of Pigment To Match With Shade Of Granite. Including Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishes Complete All As Specified. 6 Providing And Laying Premium (1St) Quality Straight Edge, Ceramic Tiles Exterior Grade Scratch Resistance Of Size 300X300X7 To 8 Mm Thick In Floors Etc. In Any Shade And Design/Pattern Of Light & Dark Tiles Etc Set And Including 15 Mm Thick Rendering In Cement Mortar (1:6) And Pointed In White Cement With Pigment To Match Complete All As Specified. 7 Taking Up Or Down Existing Steel Tubing And Connections, 15Mm Bore Complete All As Specified. 8 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 15Mm Bore Incl Fittings Complete All As Specified And Directed. 9 Taking Up Or Down Existing Steel Tubing And Connections, 20Mm Bore Complete All As Specified. 10 S&F For Cpvc Pipe Fixed On Wall/Ceiling Or Laying In Floor Of 20Mm Bore Incl Fittings Complete All As Specified And Directed. 11 S&F In Repair Angle Stop Cock With Wall Flange 15Mm Cast Copper Alloy, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No-Fon-40053Pm Or Equivalent In /Hindware/Kohlar. 12 S&F In Repair 15 Mm Bore Bib Cock With Wall Flange, Cast Copper Alloy, Chromium Plated, Fancy Type With Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Long Body.Make: Jaquar Cat Part No Opp-15037Pm Or Equivalent In/Hindware/Kohlar. 13 S&Fin Repair Brass Chromium Plated Basin Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar Cat Part No Orp-10011Bpm Or Equivalent In /Hindware/Kohlar 14 S&F In Repair 15Mm Cp Connection 600Mm Long Including Washer And Brass Nuts All As Specified. 15 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 16 S&F In Repair Counter Top Wash Basin Of Size 600 X465Mm With Wash Basin Cabinet Size 600X455X600Mm Including Bottle Trap , Brass Waste Fitting Complete All As Specified. Make:-Cera/Hindware/Jaguar 17 S&F In Repair Toilet Roll Holder Stainless Steel Flap All As Specified. Make- Jaquar Cat Part No Can-1153S Or Equivalent In /Hindware/Kohlar 18 S&F In Repair Towelrack 600Mm Long With Lower Hanger (Stainless Steel) All As Specified.(Make: Jaquar Cat Part No Acn -1181S Or Equivalent In /Hindware/Kohlar 19 S&F In Repair Soap Dispenser With Glass Bottle (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1135N As Equivalent /Hindware/Kohlar 20 S&F In Repair Soap Dish Holder With Glass (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Akp -35731P Or Equivalent In /Hindware/Kohlar 21 S&Fin Repair Towel Ring Square With Round Flange (Stainless Steel) All As Specified. Make- Jaquar Cat Part No Acn -1121N Or Equivalent In /Hindware/Kohlar 22 S&F In Repair Healthfaucet With 1Mtr Long Easy Flex Tube In Chrome Finish And Wall Hook Of 15 Mm Bore With Cp Pipe Complete Set Of Make -Jaquar Cat Part No Ald - 565 Or Equivalent In Parryware/Prayag 23 S&F In Repair Looking Mirror 5Mm Thick Size 3.5X3.5 Feet Incl Stud And Fastners Complete All As Specified And Directed. 24 S&F In Double Arm Wall Mounted Reversible Plain/Magnifying (X3) Pivotal Mirror All As Specified. Jaquar Cat Part No Acn -1193N Or Equivalent In /Hindware/Kohlar 25 S&F In Repair Glass Shelf Corner With Bracket Of Size 225Mm X 225Mm Thickness Of Glass 6Mm) With Cp Brass Railing And Brass Screws.Make- Jaquar Cat Part No Acn -1173 Or Equivalent In /Hindware/Kohlar 26 S&F Grating Doom 125Mm Of Ptmt. 27 S & F In Repair Vitreous China Urinal Half Stall Type White (Excluding Flushing Cistern ) Including Waste Fitting, Waste Pipe Complete All As Specified.Make-Jaquar/Hindware/Kohlar 28 S&F Ms Work In Tubular/Pipe/Angle Sections For Frame Work For Roof, Vertical Poles, Rafters And Purlins Including Washer Etc Complete All As Directed. 29 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Corrugated Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. ( Design Of Sheet As Mangalore Tiles Pattern In Red Colour ). 30 S & F Pre-Painted Galvalume Aluminum Zinc Coating Gi Based Plain Steel Sheet 0.50 Mm Thick Of An Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall,Fixed With Self Tapping Screws As Specified. 31 M & L Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Incl Preparation Of New Surfaces Of Any Description Over 10 Cm Width Or Girth Complete All As Specified And As Directed. 32 M&L 25Mm Thick Factory Made Coloured Interlocking Designer Polished Floor Tiles (Ultra Pattern) Of Grade M-35 Of Shape And Size As Directed,And 100Mm X 100Mm Size Tiles Piece On Every Joint Of Tiles Flooring Laid Over & Including 20Mm Thick Screed Bed In Cement Mortar 1:4 Complete All As Specified And Directed . Note: Sample Shall Be Got Approved From Ge Before Commencement Of Work 33 S&F In Repair Stainless Steel Drapery Rod Of 20 Mm Inner Dia (In Lengths As Directed) Of & Including Decorative Finial At Both Ends And Pair Of S S Steel Brackets Fixed At Both Ends With Pvc Rawl Plug & Steel Screws On Walls/Beam, (Victorian Design)All As Specified & As Directed. Make -Sample Can Be Seen In The Office Of Engg-In-Charge For Checking And Quoting The Same 34 Demolition Of Cement Concrete Un -Reinforced In Ground Floors And Pavings N.Exc 15Cm Thickness Complete All As Specified. 35 M& L For 25Mm Thick Pcc 1:2:4 Type Bo Using 12.5 Mm Graded Stone Aggregate As In Floor Complete As Specified And Directed. 36 S & F 75 Mm Dia Pvc ( Swr ) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified. 37 S & F Floor Door Stopper Of Aluminium Alloy And Tongue, Anodised With Hard Drawn Steel Overall Length Of Cover Plate 140Mm.As In Repairs Complete All As Specified. 38 Dismantling Of Wall And Ceiling Board(Fiblre, Pulp, Insulation Etc) Any Thickness Including Cover Fillets Complete All As Specified And As Directed. 39 S & F Powder Coated Aluminum Alloy Interlocking Snap Grid Frame Work For False Ceiling Size 600Mm X 600Mm Consists Of Main Tee Runners Of Size 38Mm X 38Mm X 1.5Mm And Cross Tee Of Size 38Mm X 38Mm X 1.5Mm, Spaced Between The Main Tee At 600Mm Centre To Centre To Form A Grid Of 600Mm X 600Mm Complete All As Specified And As Directed And As Per Manufacturer. Instruction. 40 M & L For 4Mm Thick Non Asbestos Fibre Cement Building Boards Of Make E Board Classic Designer Board (Cascade Or Occenic) Of M/S Everest Industries Ltd Or Equivalent As Approved, By Ge Fixed Or Laid/ Inserted To Timber/Gi/Aluminium Framework With Complete All As Specified And As Directed. 41 Taking Down Cement Mortar Plastering On Brick Or Stone Walls, Etc. Including Raking Out Joints,Hacking For Key,Scrubbing Down With Water, Etc Complete All As Specified And As Directed. 42 M&L For Rendering 15Mm (In Two Layers 10Mm+5Mm) Thick Plaster In Cm (1:4) On Faces Of Brick Work Or Concrete Surfaces, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 43 M&L For Rendering 5Mm Thick Plaster In Cm (1:3) On Faces Of Brick Work Or Concrete On Surfaces Of Ceiling, Finished Even And Smooth Without Using Extra Cement Complete All As Specified And As Directed. 44 Complete Removal Of Existing Treatment Including Washing Rubbing Down And Stopping Of Painted Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 45 M&L For New Plaster Surfaces And Applying 1-2 Mm Thick Metallic Texture Painting (Top Quality) On Walls In Any Colour/Shade/Pattern/Design Including Preperatory Work For Base By Applying Primer/Putty Coat By Any Authorised Applicator Complete All As Specified And Directed 46 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 47 M & L For Cement Concrete As Pcc 1:5:10 Type E-2 Using (40Mm Graded Stone Aggregate) As Foundations,Filling And Mass Concrete Complete All As Specified. 48 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 49 Demolition Of Brick Work Or Stone/Boulder Masonary, Laid In Cement Mortar Or Cement Lime Mortar Complete All As Specified. 50 M&L Brick Work, Straight Or Curved On Plan N.Exc 6M Mean Radius In Cm 1:6 Using Old Size Brick Complete All As Specified. 51 Taking Down Chowkat Or Frame With Shutters (With Out Taking Off Shutter From The Frame ) Not Exceeding 1.5 Sqm Each As Directed By Engineer-In-Charge. 52 S&F For Factory Made Single Extruded Wpc (Wood Polymer Composite) Solid Door Frames/Chowkhat Comprising Of 100 Mm X 65 Mm Size, Applying Pvc Solvent Cement And Screwed With Full Body Threaded, Star Headed Ss Screws Having Minimum Frame Density Of 750 Kg/Cum And Resistance To Spread Of Flame Of Class A Category With Property Of Being Termite/Borer Proof, Water/Moisture Proof And Fire Retardant And Fixed In Position With Mild Steel Hold Fast/Lugs/Ss Dash Fasteners Of Required Dia And Length Complete All As Specified And As Directed By Engr-In-Charge. 53 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Solid Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 54 S&F Stainless Steel (304 Grade) Finished Butt Hinges 125Mm Complete All As Specified And Directed 55 S & F Extruded Brass Handles, Fabricated Type Polished 150 Mm Complete All As Specified. 56 S & F Brass , Barrel Tower Bolts, With Cast Or Sheet Barrel And Rolled Or Cast Bolts And Fixed 200 Mm Complete All As Specified. 57 M&L For 250Mm Long Brass, Sliding Door Bolt Withsand Or Die-Cast Brass Hasp, Staple (Bolt Type) And Fixing Bolt With Rolled Or Drawn Brass Bolts And Fixed Complete All As Specified And As Directed. 58 Dismantling Pvc Pipes With Fittings Upto 75Mm To 110Mm Dia Complete All As Specified And Directed By Engr-In Charge.. 59 S&F For Pvc (Swr) Pipe 110 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 60 S&F For Pvc (Swr) Pipe 75 Mm Dia Single Socketed In Any Length With Rubber Ring Jointed Level Fixed To Walls Complete All As Specified And As Directed. 61 S&F For Pvc (Swr) Bends With Access Door 110 Mm Dia Complete All As Specified And As Directed. 62 All As Per Item No 61 Above But 75 Mm Dia. 63 S&F Pvc (Swr) Plain Bend 110 Mm Dia Complete All As Specified And As Directed. 64 S&F Pvc (Swr) Plain Bend 75 Mm Dia Complete All As Specified And As Directed. 65 S&F Pvc (Swr) Branch Piece Single Or Double T Equal Or Unequal With Access Door 110 Mm Dia Complete All As Specified And As Directed. 66 All As Per Item No 65 But 75 Mm Dia. 67 S&F Pvc (Swr) Vent Cowl 110 Mm Dia Complete All As Specified And As Directed. 68 Excavating In Post Holes (Or Similar Holes) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50 M And Making Good Surface 69 M&L For Cutting Chases, Pinning In, Making Good To Facings Where Required And Pointing In Cement Mortar 1:3 To Ends Or Edges Of Landings, Steps, Cills, Sunshades, Shelves, Lintels, Etc.; And Cutting Chases For Concealed Water Tubing Or Concealed Conduit Wiring, Etc. And Making Good, Cutting Not Exc 10 Cm Girth All As Specified. 70 Taking Down Carefully Existing Points Wiring On Surface Conduit/Concealed Conduit Including Conduit From Surface And Expect Conduit In Concealed Wiring For Light/Fan/Socket/Power/Bell From Wall & Roof Along With Fitting And Fixtures Such As Switches, Sockets, Ceiling Roses, Batten Holders, Unserviceable Light Fittings, Pieces Of Wires, Gutties, Conduit, Wooden Boards Etc Removing Materials To Store For Keeping In Safe Custody Of Contractor For Which The Credit Has Been Considered Under Schedule Of Credit And Making Good The Disturbed Portion Of All Floor, Ceiling Etc All As Specified And Directed. 71 M & L For Point Wiring With 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor For One Light/Fan/Bell Point In And Including New Pvc Rigid Non Metallic Concealed Conduit 19/20 Mm Dia, Medium Duty, Isi Marked To Be Terminated In Pressed Steel Terminal Boxes With Pvc Modular Top Cover Plates Of Suitable Size For Mounting Of Modular Type Switches/Sockets/Regulators Including 1.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Earth Continuity Conductor Controlled By One Switch And/Or One Regulator Complete Including Cutting Chases And Making Good The Surfaces In Cm 1:3 And Finishing The Surface As Per Existing Treatment All As Specified And Directed By Engr-In-Charge.Notes: (I) Cost Of Pressed Steel Terminal Boxes And Modular Top Cover Plate Shall Be Included In Point Wiring. (Ii) Wiring Shall Be Done As Per Colour Code In Is For Phase, Neutral And Earth.(Iii) -Cost Of Eye/Bottle Thimbles Used For Connection In Switches/Sockets & Mcbs In Dbs Shall Deemed To Be Included In The Unit Rate Quoted For This Item. 72 All As Per Sl Item No 71.00 Above Herein Before But One Socket Out Let 5 Pins 5 Amp On The Same Board With Other Switches Complete All As Specified And Directed. 73 All As Per Sl Item No 71.00 Above Herein Before But For One Socket Out Let 5 Pins 5 Amp On Independent Board Complete All As Specified And Directed. 74 All As Per Item No71.00 Herein Before But 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Single Core Multistranded Copper Conductor Incl 2.5 Sqmm Pvc Insulated And Unsheathed Frlsh Copper Earth Wire For Switch Socket Combination 3 Pin 15 Amps On Independent Board. 75 S & F In Replacement Of Modular Switch 1 Way, 6 Amps, 1 Module, 230 Volts Complete All As Specified. 76 S & F In Replacement Of Modular Switch 1 Way, 16 Amps, 1 Module, 230 Volts Complete All As Specified. 77 S & F In Replacement Of Modular Socket 5 Pin 6 Amps, 2 Module 230 Volts Complete All As Specified. 78 S & F In Replacement Of Modular Socket 5 Pin 6 &16 Amps, Combination Type 2 Module Complete All As Specified. 79 S & F In Replacement Of Modular Fan Regulator Step Type, 120 Watts, 2 Module Complete Fixed As In Repair All As Specified. 80 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 81 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Green Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 82 Supply And Fix Incl Taking Down Deco Mini Energy Efficient 0.5 Watt B22 Base Led Bulb Red Colour With Colour Temperature 6500 Kelvin, Controller Type Push Button , Globe Shape For Indoor/ Outdoor Usage All As Specified And Directed By Engr In Charge. 83 Supply And Fix Surface/Recess Mounted Led Luminaire 36 Watt Cool White 4000-5000K Suitable For Gridd Celling Cutout Dimensions: 2X2 Ft. Incl Connecting With Twin Core Copper Wire From Ceiling Rose To Fitting, Fixture Size: (Lxwxh) In (595X595X65) Mm Incl Lamp And Driver All As Specified & Directed. 84 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 18/20W 6500K Of Capacity ,20 Watt,4 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 85 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 86 Supply And Fix Mirror Light With Linear & Compact 12 W Mirror Light With Decorative Grey End Caps, Polycarbonate Body And Ribbed Opal Diffuser Of Capacity 9 Watt Complete All As Specified And Directed By Engr-In-Charge. 87 M & L For Sub Main Wiring With Two Single Core 4.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 4 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2 Runs Of 4.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 4.00 Sqm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note2 : Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Bends, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces, Cutting Not Exc. 10 Cm Girth . (Iii) Taking Out/Down Existing Unserviceable Sub Main Wiring. 88 Taking Down And Refixing Of Ceiling Fan After Supply And Replacement Of Rubber Reel, Round Cover Plate Of Size 6 Inch Of Ceiling Fan Complete With Ms Split Clamp Two Nos, Nuts And Bolts Complete All As Specified And Directed By Engr-In-Charge. 89 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 250 Mm Sweep 900 Rpm Engineering Thermoplastic Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Louver Complete All As Specified And Directed By Engineer-In-Charge. 90 Material And Labour For Making Hole Of Suitable Size For Exhaust Fan 250 Mm/ 300Mm Sweep In Wall For Grouting And Making Good The Surface Complete All As Specified And Directed By Engr-In-Charge. 91 Supply And Fixing Single Pole And Neutral Enclosure With A Two Pin And Earth Plug And Socket Complete With Mcb Spn 32 Amps, Complete All As Specified And As Directed By Engineer-In-Charge. 92 S&F Poly Coated Gi Frame Work As In Grid For False Ceiling Comprising Of Protected Gi Perimeter Channel 0.55 Mm Thick With Two Unequal Flanges Of 20 And 30Mm And Web Of 27Mm Fixed To Surrounding Wall Using Nylon Sleves And Screws At 450Mm Centre To Centre/Intermediate Chaqnnel 0.9Mm Thick Having To Equal Flanges Of 15Mm Each And Web Of 45 Mm Suspended From Soffit And Approx 900Mm Centre To Centre With Gi Cleat And Steel Expansion Fasterners With And Including Ceiling Section (Not Exc 1.2 Metre Length) Of 0.55Mm Thickness Having Kurled Web Of 50Mm And Flange Of 26Mm Each With Lips Of 10.5Mm Fixed To The Intermediate Channel With Connecting Clips Acorss The Intermediate Channel At 457Mm Centre To Centre And Hangers 6Mm Dia Gi (Upto 1200 Mm Length Adjusting Level Fixed To Roof Slabs By Means Of Ceiling Cleats Made Out Of Gi Flat 40 X3Mm Size 60Mm Long Complete With And Including 7Mm Thick Pvc Laminated Gypsum Tiles Of Size 595X595Mm Complete All As Specified & Directed 93 M&L For Complete Removal Of Existing Surfaces Of Walls Including Cornices, Pillasters Etc, And Applying Two Coats Of Obd Over And Incl A Coat Of Interior Wall Primer Over Wall Care Putty Complete All As Specified And Directed. 94 M&L For Complete Removal Of Existing Treatment On Walls And Applying 02 Coats Of Exterior Weather Emulsion Paint To External Walls/Rcc Surfaces/Soffits Of Chajjas/Roof Projections/Cantilevers/Balcony Etc Surfaces Over & Including A Coat Of Exterior Wall Primer And Over Wall Care Putty Complete All As Specified. 95 S&F Stainless Steel Tubing Of 25 Mm Dia Chromium Plated Min. 1.0 Mm Wall Thickness As In Curtain Rod Complete Incl S&F 02 Nos Stainless Steel Brackets/Finials Fency Type, Stops Fixed With Ss Screws Etc All As Specified & Directed.Note : For The Purpose Of Mesurement And Payment Running Length Of Curtain Rod Only Shall Be Considered. 96 Taking Down Chowkhats Or Frames Of Any Description Exc 1.5 Sqm And N. Exc. 4 Sqm Each (Without Taking Off Shutters From The Frame) Including Cutting Hole To Size For Receive Fresh Pcc Of Hold Fast And Making Good The Disturbed Surface Same Complete All As Specified And Directed. 97 S&F Factory Made Pressed Steel Frames Made Of Ms Sheet Of 1.20 Mm Thickness For Doors With One Or More Rebates Including Necessary Fixing Lugs, Hinges, Lock Strike Plate, Etc., Complete As Specified,Size 125X60Mm 98 M&L Pcc 1:3:6 Type C-0 In 12.5 Mm Graded Stone Aggregates Hold Fast Fillinng Inside Frame & Hold Fasts Etc Complete All As Specified 99 S&F Factory Made Flush Shutters 35Mm Thick Ply Construction, Bwp Confirming To Is 2202, Solid Core Construction, With Block Board Core And Plywood Face Panels Commercial Type On Both Sides With 6Mm Thick Lipping Frame To Match Including Supply And Fixing Following Items :(A) Mild Steel Butt Hinges 125Mm - 3 Nos. Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos. Per Leaf(D) Stainless Steel (804 Grade) Finished Sliding Bolt 250 Mm - 1 No. Per Leaf(E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 100 S&F 35Mm Thick Glazed And Skelton Shutters Of 2Nd Class Hard Wood (Factory Made) Open Rebated And Divided To Receive Glass, Gauze Etc (Without Sash Bars) Edges Of Framing Plain, Chamfered Or Rounded Fitted With Cut And Mitred Beads For Securing Glass Etc Size Of Members Of Shutter As Specified In Ssr-91 Pt-1 Section 8 Clause 8.20(A), Kiln Seasoned And Chemically Pressure Treated All As Specified Including Stainless Steel 304 Grade Wire Cloth (0.36Mm Nominal Dia Of Wire And Average Width Of Aperture 1.40Mm) All As Specified And Including Supply And Fixing Following Items :(A) Stainless Steel (304 Grade) Finished Butt Hinges 125Mm - 3 Nos Per Leaf(B) Stainless Steel (304 Grade) Finished Tower Bolt 200Mm Long - 2 Nos Per Leaf(C) Stainless Steel (304 Grade) Finished Handles 150 Mm - 2 Nos Per Leaf(D) Stainless Steel (304 Grade) Finished Sliding Door Bolt/Aldrop 16X250Mm - 1 No Per Leaf (E) Stainless Steel (304 Grade) Finished Floor Door Stooper - 1 Nos. Per Leaf. 101 M&L For Two Coat Of Synthetic Enamel Paint (Finishing Coat) Over One Coat Of Pink Primer To New Wooden Surfaces Of Any Description Over 10 Cm Width Or Girth Incl Prepration Of Surfaces Complete All As Specified And Directed. 102 S&F 300Mm, Ordinary Rat Tail Rod Pattern Springs Including Roller And Roller Plate Complete All As Specified And Directed. 103 S & F In Replacement Of Ceiling Rose Surface Bakelite Surface 65 X 50Mm 3 Terminals All As Specified & Directed 104 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X35 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 105 S & F In Replacement Of Surface Mounted Led Bulk Head Luminaire Of Capacity 10 Watt With Abs Body & Polycarbonate Diffuser, Ip54 Inc Connection With ,With Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 106 Supply And Fix Lamp Holder Including Led Bulb 9 W Including Flexible Wire 0.5 Sqmm Copper Cable All As Specified & Directed By Engr-In-Charge. 107 M & L For Sub Main Wiring With Two Single Core 6.0 Sqmm Pvc Insulated And Unsheathed Frlsh ,Stranded Copper Conductor Cable Drawn Through Pvc Concealed Conduit 25 Mm Dia Including 6.0 Sqmm Pvc Insulated Unsheathed Frlsh Stranded Copper Conductor Cable As Earth Wire All As Specified And Directed By Engineer-In-Charge. Note 1:- 2(Two) Runs Of 6.00 Sqmm Copper Conductor Cable, 1 Run Of Pvc Conduit & 1 Run Of 6.00 Sqmm Copper Conductor Earth Wire Shall Be Measured As One Unit) Note 2 :(I) Rate Quoted For This Items Shall Be Inclusive Of The Cost Of (I) Rigid Non-Metallic Pvc Conduit Of 25 Mm Dia With Tees, Elbows, Reducers, Bell Mouth Tube Ends And Fixing Accessories Such As Couplers, Lock Nuts, Saddles, Pipe Hooks Etc. (Ii) Cutting Chases, Pinning In Making Good To Facing Where Required And Pointing In Cement Mortar 1:3 To Match The Existing Surfaces And Cutting Not Exc. 10 Cm Girth . (Iii) Including Taking Out/Down Existing Unserviceable Sub Main Wiring. 108 S & F In Replacement Of Sheet Metal Enclosure Db Tpn 4 Ways Double Door 415 Volts With 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables Complete With Ip-43 Protection Complete All As Specified And Directed By Engr-In-Charge 109 S & F In Replacement Of Mcb, Triple Pole & Neutral (Tpn) 10 Ka 240 Volts 40 To 63 Amp Capacity Fixing In Db’S Complete All As Specified And Directed. (Note: Mcb Should Be B Or C Curve As Directed By Engineer In Charge) 110 Supply And Fix In Replacement Of Sheet Metal Enclosure 8 Ways Double Door For Dbs When Mcbs Are To Be Used 240,Volts Including 200 Amps Standard Bus Bar Of Suitable Size And Common Neutral Link All Flush Mounting Type, Drilling Holes For Incoming And Out Going Cables With Ip43 Protection Complete All As Specified & Directed By Engr-In-Charge. 111 S & F In Replacement Of Mcb, Single Pole 240 Volts 6 To 32 Amp Capacity For Fixing In Db’S Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 112 Supply And Fix In Replacement Of Mcb , Spn, 240 Volts ,40-63 Amp For Fixing In Dbs Of Including Proper Thimble Connections Complete All As Specified And Directed By Engineer-In-Charge. 113 M & L In Replacement Of Unsv Earthing Complete With Galvanized Iron Earth Plate Electrode Of Size 600X600X6.0Mm , Buried Directly In Ground (Earth Pit Not Less Than 2.25 Mtrs Below Normal Ground Level) With Top Edge Of Earth Plate Not Less Than 1.5 Mtr Below Normal Ground Level, Connected To Galvanized Earth Lead Wire 4.0 Mm Dia By Means Of Bolts , Nuts , Check Nuts And Galvanized Iron Or Steel Including Earth Work In Any Type Of Soil, Charcoal Salt 15 Cm Around The Earth Plate 20 Mm Dia Watering Pipe Medium Grade 1.70 Mtr Long With A Plug At Top, Gi Protection Pipe Light Grade 15 Mm Dia From Earth Pit To Main Board Including Pcc Pit In Cement Concrete 1:2:4 Along With Ci Frame And Cover 10Mm Thick Duly Hinged To Ci Frame As Shown In The Electrical Plate No3 Of Ssr 2009 Part 1 Specification At Page 497. 114 Xlpe Insulated ,Screened, Pvc Bedded, Galvanized Steel Wire Armoured, Electric Power Cables (Heavy Duty) 1100 Volts Grade With Stranded Aluminium Conductor Of Size 25 Sq Mm 4 Core Supplied & Laid In Replacement Complete All As Specified& Directed By Engineer-In-Charge. 115 Excavation In Trenches Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth For Laying Of Cables Including Getting Out In Any Kind Of Soil Complete All As Specified And Directed. 116 Returning Filling In Including Spreading, Levelling, And Well Ramming, In Layers Not Exceeding 25 Cm Each Layer Of Any Kind Of Soil. 117 Removing Surplus Excavated Material From Site Not Exceeding 50 Mtrs From Starting Point And Depositing Where Directed At Level Not Exceeding 1.5 Mtr Above The Starting Point. 118 Material And Labour For Sand Cushioning For Cables 8 Cm Below The Cable And 15 Cm Above With Dry River Sand In Trenches For Cushioning Of Underground Cable Line Including Spreading, Leveling, Well Ramming Completed All As Specified And Directed. 119 Cutting Of Hardstanding Floor/Wall For Laying Of Cable Including Matching With Suface By Using Cement Concrete All As Specified And Directed. 120 Supplying & Laying Factory Made Unreinforced Precast Concrete Cable Covers Class Lv Type 1, Flat, Size 250X150X40Mm Laid In Trenches As Protection To Cables Complete All As Directed By Engr-In-Charge 121 Material And Labour For Replacement Of Gi Tubing Light Grade 40 Mm Bore For Passing Through Cables Under The Floor ,Along The Wall Or Along The Pole Complete All As Specified And Directed. 122 Dismantling Of Stone Slab And Tiles Laid Bedded And Pointed In Any Mortar Description Or Thickness In Floors, Apron Etc Complete All As Specified. 123 M & L For Screed Bed Or Bedding Layer Of Mortar 15 Mm Thick In Cm 1:6 For Laying Floor Finishes Complete All As Specified. 124 M&L For Virified Ceramic Light Shade Tiles 8 - 10 Mm Thick (Square/ Rectangular) Polished, Area Of Each Tiles Not Exceeding 0.36 Sqm, In Floors Etc,Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Epoxy Cartridge Tile Grout Using Fill The Joint Of Tiles Complete All As Specified.Note- Epoxy Black,Golden Colour. 125 All As Per Item No 124 But As A Skirting Incl. 10Mm Thick Rendering As In Back Coat Complete All As Specified. 126 M&L For 7 To 8 Mm Ant-Skid Ceramic Joint Free Premium Quality Coloured Tiles Area Of Each Tile Esc 0.06 Spm But Next 0.11Sqm, As In Floors Etc. In Any Pattern Ghe & Dark Tiles As Approved, Set And Jointed In Neat Cement Slurry And Pointed In White Or Coloured Cement To Match, In Floors Etc. Over & Including 15 Mm Thick Screed In Cement Mortar (1:4) Over And Pointed In White Cement With Pigment To Match The Colour Of Tiles Complete All As Specified. 127 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Laid Over Cement Screed Base 15Mm Thick In Cm 1:6 And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 128 Rounding To Edges Of Stone Slabs One Edge, Such As In Steps, Cooking Platform, And Other Similar Situations All As Specified. 129 Dismantling Water Tanks And Removing To Store Of Capacity Exc 500 & Not Exc 1000 Ltrs Complete All As Specified. 130 Supply And And Fixing, Hoisting Pvc Tank Of 1000 Ltr Capacity Including Supplied And Fixed 20Mm Dia Ptmt With Epoxy Coated Aluminium Rod And High Density Plastic Ball Screwed For Iron Pipe And Fixed.(Minimum Weight 15Mm-142 Gms/20Mm-210Gms/25Mm-455 Gms/40Mm-690 Gms Float Valve Assembly Complete All As Specified And Directed. 131 S&F In Repair Wall Mixture Mixing Valves Incl. Three Joints To Steel Pipes Or Unions 15 Mm Bore Fancy Type Best Quality As Per Sample Approved By Ge Make-Jaquar Cat Part No Qqp-7217Pm Or Equivalent In Hindware/Kohlar. 132 S&F Pvc Cabinet 600X450Mm Overall Size With Looking Mirror Of Selected Qality Glass Mountedover Pvc Framing As Per Sample Complete Fixed In Repair Complete All As Specified. 133 S&F Stainless Steel Plate Rack Of Size Not Less Than 90Cmx75Cm(Wt N. Less Than 4 Kg) Fixed With Stainless Steel Screw Including Taking Out Old Unserviceable Wooden Plate Rack As Approved By Ge Complete All As Specified. 134 S&F In Repairs Chromium Plated Shower Roses With Swivel Joints 125 Mm Dia Size Incl Fixing To Gi Pipe/Union Fixed Make-Jaquar /Hindware/Kohlar. 135 M & L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:6 Finished Even And Smooth ( Without Using Extra Cement ) With Sagol Finish On Plastered Surface Complete All As Specified And As Directed. 136 M&L For Preparation Of New Decorated Plastered Or Unplastered Surfaces Of Walls And Applying Two Coats Of Exterior Emulsion Over One Coat Of Primer And Over 2Mm Thick Putty For Levelling And Smoothening, Complete All As Specified And Directed. 137 M&L Preparation Of New Plastered Surface Of Walls And Applying Two Coats Of Oil Bound Distemper Over 1.5Mm Thick Wall Care Putty Complete All As Specified And Directed. 138 M&L For Preparing New Plastered Or Unplastered Surfaces Of Ceiling, And Applying Three Coats Of White Wash Complete All As Specified And Directed. 139 S&F Sinks With Drainage Board Made Of Stainless Steel Lmm Thickkitchen Or Laboratory With Plugs,Washers And Wastes; Including Bedding In Cement Mortar To Dwarf Wall Or Including Fixing Cantilever Brackets And Connecting Union To Pipe Overall Size 915Mm X 460Mm Bowl Size 410Mm X 330Mm X 160Mm Complete All As Specified And Directed. 140 S&F In Repair Brass Chromium Plated Sink Mixer For Mixing Hot & Cold Water Screwed Down For Iron Pipe Of 15Mm Bore All As Specified And As Directed. Make: Jaquar /Hindware/Kohlar 141 S&F Powder Coated Anodised Aluminium Frame For Doors, Windows Ventilators With One Or More Rebates Including Joining Cleat For Fixing Etc. Complete All As Specified And Directed. 142 S&F Frosted Glass 4.00Mm Thick Ordinary Quality And Glazing With Oil Putty In Square N.Exc 0.50Sqm In Each Panes Complete All As Specified And Directed. 143 S&F 28-30 Mm Thick Moulded Wpc Factory Made 100% Sketon/Glased Door (Conforming As Per Is-4020) Made From 100% Lead Free Single Extruded With 2, 4 Or 6 Raised Panel Design On The Front Side With 10 Mm Deep Mould On Single Side With Wood Grain Texture And Back Side Palin With Density Not Less Than 600 Kg/Cum. Manufactured By An Iso : 9001-2015 Certified Company. The Door Should Be Water Proof, Termite Proof, Fire Etardant And Having Screw Holding Capacity Complete All As Specified 144 S&F Factory Made Wpc Extruded Board Cnc Machine Cut Jali Fixed To Skelton Door As Per Approved Design Complete All As Specified And Directed 145 S&F Kitchen Cabinets Including All Fittings And Fixtures Incl The Follwing. (A) 19Mm Thick Plywood Of Commercial Block Board,Make: Kitply/Century Ply/ Green Ply(B) 1Mm Thick Commerical Lamination On Both Side Fixed To Black Board(Colour And Design As Approved)(C) Ss Pullout Basket Ss Finish Of Plain 15 X 20 X 6 (D) D Type Handle 100Mm Ss Finish(E) Pullout Basket Ss Finish Cutlery Wire Of Size 15X20X4 (F) 2Nd Class Hard As In Frame Work(G)Ss Channels For Pullout Basket As Required. (Note:- The Measurement Shall Be Taken From Front Elevation And Not Girthwise. 146 S&F Factory Made Upvc Brown Colour Door Shutter Made Of Extruded Profile With Wall Thickness Of 2.3Mm(+-0.2Mm) Door Profile With Hollow Section With Multy Chamber. Frame (60X62Mm),Sash(42Mmx67Mm).Sliding Interlock(One Verticle Length In Each Shutter)(45.5Mmx28Mm).Glazing Bead(24.5Mmx16Mm)Will Be Mittred Cut And Fusion Welded At All Corner.Including Drilling Holes For Fixing Hardware And Drainge Of Water Etc Am,.Making Arrangement For Fixing Of Hardware.Epdm Gasket,1.2+0.2 Mm Thick Galvanised Steel Frame(30Mmx21.5Mm).Sash (30Mmx18Mm)Profile To Be Inserted In Required Profile.Frame Will Be Finshed To The Wall With 8Mmx100Mm Long Fasteners.Hardware Touch Lockof Zinc Alloyed(Brown Powder Coated)Steel Roller System Including 5Mm Thick Glazing With Selected Quality Glass ,Aluminium Track And Bottom Rail For Two Track Sliding Fram,Wool Pine For Sliding Sash And Interlock. Note.The Unit Rate Coated By Contractor Includes Cost Of Glass And All Other Conncted Accessories,Net Opening Will Be Measured For Purpose.Make:H2O Window,Fenesta,Anuplast As Approved By Ge. 147 M&L For Rcc 1:2:4 Type B-1 Using 20Mm Graded Crushed Stone Aggregate In Any Situation Except Foundation Complete All As Specified And Directed. 148 S&F 10Mm Dia And Above Tmt Bars Cut To Length, Bend To Shape As Required Including Cranking, Hooking Ends & Binding With Mild Steel Wire (Annealed) Not Less Than 0.9Mm Dia Complete All As Specified And Directd. 149 All As Item No 77 Here In Before But 5Mm Dia And Over Upto & Including 10Mm Dia In Stirrups, Spaces & Binder Complete All As Specified And Directd. 150 S & F Powder Coated Aluminium Window/Ventilator Shutters, Side Hung Type With Sash Bars, Including Necessay Joinery Cleats, Glazing Clips, Rubber Packing, Chowkats Aluminium Snap Beading, Screws, Suitable Handle Etc With And Including Sheet Glass Or Ordinary Glazing Quality Of 4Mm Thick And Incl Gi Wire Mesh 0.56 Mm Nominal Dia Of Wire And Average Width Of Aperture 1.18 Mm , Size Of Side Rails , Top Rails , Bottom Rail 85X44.5Mm And Size Of Chowkat Frame 101.6X44.45Mm And Thickness Of Aluminium Member Shall Be 1.40Mm Thick Complete All As Specified. 151 S&F For Prelaminated Particle Board 18/19 Mm Interior Grade Prelaminated On One Side With Decorative Choice Lamination And Other Side Balancing White Lamination Fixed With Screw Timber Frame Work Including Dismantling Board All As Specified. 152 S&F In Repair Continuous (Paino) Hinges, Mild Steel, Bright Finish Or Electrogalvanised Width Of Flap (When Open) In 40Mm All As Specified. 153 S&F In Repair 40Mm Dia, Cupboard Knobs Fixed With Nut, Screw And Washer Of Mild Steel Bright Finished All As Specified. 154 S&F Ball Catches With 8Mm Dia Steel Ball And Brass Body And Striking Plate Including Letting In And Fixing Complete All As Specified. 155 Supply & Fix In Replacement Of Modular Bell Push Switch 1 Way, 6 Amps, 1 Module Complete All As Specified. 156 Supply & Fix In Replacement Of Call Bell Ding Dong Ac 230 Volt Single Pole Complete All As Specified. 157 Supply And Fix Exhaust Fan Ac Single Phase 230/240 V Of Size 300 Mm Sweep 900 Rpm Metal Body, High Efficiency Motor, Dynamically Balanced Blade For Better Performance And Corrosion-Resistant Powder Coated Metallic Finish Including Hole Making Louver Complete All As Specified And Directed By Engineer-In-Charge. 158 S & F Modern Energy Efficient Bedroom Muziris Wall Decorative Light Of Capacity 20 Watt Single Headed 240 Volt, Ip20 Rating, Controller Type (Push Button), Product Weight 1.04 Kg, Body Material (Metal), Power Source (Corded Electric),Lamp Base E27, Colour(Bronze) Incl Electrically Connection , Including Removing Of Unserviceable Decorative Light Fittings Of Any Description Complete All As Specified And Directed By Engr-In-Charge. Make: Philips Model No 31425 Or As Equivalent. 159 Excavating In Trenches N Exc 1.50M In Width And N Exc 1.50M In Depth For Foundation, Manholes Etc As Well As N Exc 10 Sqm On Plan Area And Getting Out In Soft/Loose Soil All As Specified And Directed. 160 M&L For Pcc 1:5:10 Type E-2, Using 40Mm Graded Crushed Stone Aggregate In Foundation, Filling And Mass Concrete All As Specified And Directed. 161 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 162 S&F Mild Steel Deformed Bars, 6Mm To 8Mm Dia Cut To Length, Bent To Shape Required Including Cranking And Binding With & Including Mild Steel Wire (Annealed) Not Less Than 0-.90Mm Dia Complete. 163 M&L For Form Work To Soffits Of Suspended Slabs Such As Roof Slabs Etc For Rough Finished Concrete Surface Complete All As Specified And Directed. 164 M&L For Form Work To Sides For Slabs And Sides Of Rcc/Pcc Bands In Walls, Horizontal Or Sloping And Similar Work Exc 10 Cm But N Exc 20 Cm Wide For Fair Finished Concrete Surface Complete All As Specified And Directed. 165 Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits (If Any) Of Foundation And Plinth Beams And Similar Work, Vertical Or To Batter For Rough Finished Flat Surfaces Of Concrete. 166 Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchions, Square, Rectangular Or Polygonal For Rough Finished Flat Surfaces Of Concrete. 167 M&L For Rendering In Cement Mortar (1:6) 10 Mm Thick Finished Even Smooth Complete All As Specified On Brick Or Concrete Surface Of Fair Faces. 168 M&L 15Mm Thick Cement Plaster In Two Layer First Coat In Cm 1:6,10Cm Thick & Second Layer 5Mm Thick In Cm 1:4 Mixed With Wpc 3% By Weight Of Cement Including Finishing Fair & Even On Brick Or Concrete Surfaces Of Othern Than Fair Faces. 169 M&L For 5Mm Thick Cement Plastering To Rcc Surfaces In Cm :1:3) Finished Even And Smooth W/O Using Extra Cement On Ceiling Surfaces. 170 S&F Stainless Steel Butt Hinges Medium Weight Cold Rolled Isi Marked Of Size 100 Mm Complete All As Specified And Directed. 171 M&L For Ms Framed Guard Bars Conforming To Fe-410-0 Or Fe-310-0 Welded To Steel Windows/Ventilations Complete All As Specified And Directed. 172 S&F Vitrous China Squatting Pan Of Orissa Patterns Long Pan Size 580Mx440Mm White With P Or S Trap Front Of Back Inlet And Foot Rest Including Long Band Any Pattern (Excluding Flushing Cistern And Flush Pipe) Including Provision For Lime Concrete Bedding. 173 S&F Pvc Flushing Cistern Low Level 10 Ltr Cap With Inlet Ball Valve Float And Handle Syphonic Action Type Incl Brackets And Flush Pipe Of Polythene Of Low Or High Density Isi Marked. 174 S & F In Repairs Vitreous China Oval Shape Wash Basin, White, Flat Back, Size 580 X 450 Mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopper But Including Brackets With 32 Mm Dia Waste Fittings, Brass, Chromium Plated With Waste Pipe Complete All As Specified. 175 S&F Looking Mirror Of Selected Quality Mounted On 6 Mm Thick Ply And Fixed To Wall With Wooden Plugs Chromium Plated Brass Screws And Washers. 176 S&F For Ci Floor Trap With Incl Jointing With Waste Pipe In Cement Mortar Of Size 100Mm. 177 S&F Gully Trap Stone Ware Square Of Round Mounted Type P Of Size 150X150Mm. 178 S&F 20Mm Dia Stop Valve Of Copper Alloy Screwed Down High Pressure With Crutch Or Butter Fly Handle Screwed On Both Ends For Iron Pipe Or For Union Fixed. 179 S&F Pvc Connection 15Mm Dia 600Mm Long Of Heavy Grade Screwed One End To Inlet Of Whb/Pillar Tap/Cistern Etc Complete Incl Brass Union Coupling On Both Ends Connfirming To Is-3076 Complete With Connector For Connection Old Water. 180 S& F For Ci Pipe 75Mm Dia Laid In Floor In Any Length With Or Without Cars With Cement Joint (Waste & Vent Pipe). 181 All As Per Item No 38 Here In Before But 100Mm Dia. 182 S&F For Ci Bend Any Radius Disminshing Pieces Or Tyes Of 100Mm Bore With Ducks For Or Head Rest. 183 S&F For Ci Branch Pieces Single Equal Or Unequal Ordinary Or Inverted Or With Paralled Brnach 100 Mm Bore. 184 S&F Cast Iron Sand Cast Pipe 100 Mm Dia With Or Without Cars With Cement Joint Fixed To Walls. 185 S&F Cast Iron 100 Mm Cowl. 186 M&L For Pcc 1:4:8 Type D-2 Using 40Mm Graded Stone Aggregate)75Mm Thick On In Sub Base Of Fllor .. 187 M&L For 15Mm Thick Screed Bed Or Bedding Layer In Cm 1:6 Complete All As Specified And Directd. 188 M&L For Coloured Glazed Ceramic Tiles On Vertical Surface (300Mmx600Mx7M) Thick Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 189 M&L For Coloured Non Skid Ceramic(300X300Mm) Tiles 7 To 8Mm Thick As In Floor Set And Jointed In Neat Cement Slurry And Pointed With White Cement To Match Complete All As Specified And Directd. 190 S&F Steel Ventilation With Top Hung Shutter Including Hinges, Steel Peg Stay Complete. 191 S&F 4Mm Thick Sheet Glass Of Figured,Pin Headed And Glazing With Oil Putty In Square N Exc 0.50 Sqm In Each. 192 M&L For Preparation Of Newly Steel Surfaces And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Over 10 Cm Width Or Girth Complete All As Specified And Directd. 193 M&L For Preparation Of Newly Plastered Surfaces And Applying Two Coats Of Cement Base Paint Over A Coat Of Chalk Whiting Complete All As Specified And Directd. 194 M&L For Three Coats Of White Wash On Wall Of Newly Plastered Surface. 195 S&F For Preparation Of Newly Plastered Surfaces And Applying Three Coats Of White Wash On Ceiling. 196 M & L For Factory Made Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With M.S Square Tube, Supplying & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. 197 S&F Factory Made Solid Pvc Moulded Door Shutter, With Particle Board Core, 28 To 30Mm Thick (Stiles), With 2, 4, Or 6 Raised Panel Design With 2Mm Thick Moulded Pvc Sheet On The Front Face & 2Mm Plain Colour Pvc Sheet On Back Face & 5Mm Thick Plain Colour Pvc Sheet On Back Face, Supplying & Fixing In Frame At Site As Per Specification & Drawing All As Specified. 198 S&F Aluminium Tower Bolt 150Mm Long Stove Enamelled Black With Bright Bolt & Fixed. 199 S&F Aluminium Sliding Door Bolt With Hasp And Staples Type Bolt Type , 300Mm Long Stove Enamelled And Fixing Clips Of Sheet Cast Or Extruded Section Or Cast Aluminium Alloy And Fixed All As Specified. 200 S&F Aluminium Alloy Handle Of 100M Size Oval Type Stove Enamelled & Fixed All As Specified. 201 M&L For Rendering 10Mm Thick Cm (1:4) On Roof Slab Top, Mixed With Water Proofing Liquid Finished Even And Fair Without Using Extra Cement Complete All As Specified. Note: Water Proofing Liquid Shall Be Measured And Paid Separately. 202 M & L For Cleaning The Newly Plastered Surfaces Of Concrete ( Roof Etc) With Wire Brushes And Applying Water Proofing Treatment As Under :-I) Apply One Coat Of Oil Bound Bituminous Primer @ 0.25 Kg/Sq.M Ii) Providing And Laying 3 Mm Thick App Modified Water Proofing Membrane Weighing Not Less Than 3.5 Kg / Sqm Reinforced With Non Woven Polyester Mat Weighing Not Less Than 160 Gm/Sqm All As Specified Procured From Any One Of The Approved ManufacturerS Iii) Apply One Coat Of Solar Reflective Bituminous Aluminium Paint @ 0.15 Kg/Sqm Over Membrane Over Non Assesble Roof Surfaces Complete All As Per ManufacturerS Instructions And As Directed . 203 M/L Brick Work In Cm1:4, In Half Brick Thick Wall. 204 S&F In Repair Europen Wc China Ware Coloured Cascade With Cistern And Complete Fitting.Make: Jaquar/Hindware/Kohlar 205 S/F Vitreous China Toilet Paper Holder Fixed To Walls With Chromium Plated Cp) Brass Screws 206 S/F Vitreous China Soap Dish Of Appx Size 160*160*90Mm Any Type Fixed To Plugs With Chromium Plated Brass Screws 207 S/F Sheet Glass Shelf Assembly Consistig Of 5.5Mm Thick Sheet Glass Shelf 12Cm Wide With Chromium Plated Brackets Guard And Railing 60Cm Long 208 S & F Brass Chromium Plated Tubular Towel Rail, 20 Mm Dia, D Type, 60 Cm Long Between Flanges Complete All As Specified. 209 M & L For Granite 20 Mm Thick Machine Cut, Bedded And Jointed With Grey Cement Slurry And Pointed With White Cement With Admixture Of Pigment To Match The Shade Of Granite Stone Including Griding And Polishing Types All As Specified. 210 M & L For Machine Cut Cudappa Stone Slab 20 - 25 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified. 211 M&L For 75 Mm Thick Pcc 1:3:6 Type C-1 (Using 20Mm Graded Stone Aggregate) As In Plinth Protection/Floors Complete All As Specified And Directed. 212 S&F Health Faucet Including Ms/Anodised Hanging Device Fixed Complete All As Specified And As Directed. 213 Surface Excavation Not Exceeding 30Cm Deep And Averaging 15Cm Deep And Getting Out In Loose / Soft Soil All As Specified And Directed. 214 M&L For Broken Stone Hard Core Of Gauge N. Exc 63Mm, Deposited, Spread And Levelled In Layers N Exc 15Cm Thick, Watered And Rammed To A True Surface All As Specified And Directed. 215 M & L 100Mm Thick Pcc 1: 4: 8 Type D2 (Using 40Mm Graded Stone Aggregate) As In Sub Base Complete All As Specified And Directed. 216 M&L For Machine Pressed Precast Concrete Interlocking Paver Block Rubber Moulded Any Shape And Size Confirming To Is 15658-2006 Of 60Mm Thickness, M-35 Grade With Grey And Pigment As In Floor/Pavement Complete All As Specified And As Directed. 217 M&L For Providing Precast Concrete Type C-1, 1:2:4(Using 20Mm Graded Stone Aggregate) As In Kerb Blocks With Plain Fiar Faces, Including Chamferes, Weathering, Throating Etc And Setting In Mortar 1:4 Complete With Joints To Match. 218 M&L For Cement Concrete Type 1:4:8 Type D-2 (Using 40Mm Graded Stone Aggregate) As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 219 M & L For Sand Filling Under Floors Or In Foundation Including Watering And Consolidation 220 S & F In Replacement Of New Generation Energy Saving And Environmental Friendly Long Life Led Building Security Light 1X25 Watts Made Up Of Pressure Die Cast Alluminium Housing With High Power Led As Light Source And Lense Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip65 Protection And Impact Resistance Of Ik07, With All Accessories Including Suitable Bracket With 32Mm Bore Light Grade Gi Pipe Bemd To Shape, Including Ms Clamp Of Size Of Required Size And Pvc Cable 1.5 Sqmm Twincore From Ceiling Rose To Light Fittings Complete All As Specified And Directed By Engineer-In-Charge. 221 S & F In Replacement Tube Light Fitting Self Ballasted Led Batten. Extruded Thermoplastic Body With Pc Diffuser In Square Led Batten 9/10W 6500K Of Capacity ,10 Watt,2 Ft Long Incl 3 Core Flexible Wire 0.5 Sqmm Copper Cable All As Specified And Directed By Engr-In-Charge. 222 M&L For Boring Of Holes Under Road, Pavement, Hard Standing By Trench-Less Technology Using Ultrasound Technique And Necessary Machine Suitable To Pass Through 40 To 80 Mm Bore Gi Tubing And Cable Etc Complete All As Specified And Directed.Note: Gi Pipe Shall Be Measured And Paid Seperately Under Relevant Item.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
2.
Water Resources and Irrigation #11467167 AOC
Periodical and Emergent electrical maintenance under jurisdiction of Mukutmanipur Electrical and Water supply section etc during the year of 2025-26.- 1 Emergent Electrical maintenance work as & when required basis under the jurisdiction of Mukutmanipur Electrical & Water supply section. 2 a) Electrican 3 b)Helper for Electrician 4 Emergent Electrical maintenance work for the Flooding period in the jurisdiction of Mukutmanipur Electrical & Water supply section i.e. LBHR,RBHR, Kangsabati Bhawan etc. for 123 days as per direction of E.I.C. 5 a) Electrican 6 b) Helper for Electrician 7 Periodical and Emergent electricial maintenance work and pump operation for one year under jurisdiction of Mukutmanipur Electrical and Water supply section i.e.,LBHR, RBHR, Kangsabati Bhawan, Mukutmanipur colony etc. 8 a) Electrican 9 b)Helper for Electrician 10 Opening the Ceiling fan testing, checking and Re-winding by supplying super enamelled copper wire of appropriate gauge, minilex paper, mica sheet, changing the loops, overhauling, backing, varnishing, re-fitting and using and measuring r.p.m. for ceiling fan above 36 sweep up to 60 sweep. 11 Supplying following sizes Capacitor of 250V rating: 2.5 MFD Capacitor (Universal Make or equivalent). 12 Supply Philips LED tube, model no : Mas LEDtube 1200mm 18W865 T8 I - 2100lm. 13 Supply of 2X20 T8 tube holder alongwith2 nos. 20 Watt T8 LED Tubes Specification T8 LED Tube , CCT-6500K, Lumen-2200, Make-Magik/ any, approved make. 14 Supply and fixing of smart bright essential street light complete with all accessories to be fixed / projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. 72 watt with Toughend glass , 130 lm/w, Spd 15 kva at least and 5 years warrenty etc, Surya/ Crompton make. 15 Supply and fixing of smart bright street light (36 Watt)complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. Make: Crompton/Magik, 36 watt,USOR (M&E) , page-111, Items Sl no -5.3 F.9 16 Supply and fixing of GreenLED Ultima Square (6 x 6) , incl cutting the false ceiling in reqd dimensions also the wiring and connection of the light by 1.5 sq mm cu wire complete. Make: Crompton, 18 watt square/ round , 17 Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Anchor penta) on existingModular GI switch board with top cover plate incl. making necy. connections etc, 18 Supply 16A Modular type Switch(Brand approved by EIC). 19 Supply of ammeter selector switch Current in Each phasewith OFF, 4 Pos. 90° angle of throw (OFF-R-Y-B), 20 Supply of voltmeter selector switch Votage between phaseswith OFF, 4 Pos. 90° angle of throw (OFF-RY-YB-BR), 21 Supply of 22.5 mm Hole Dia Mushroom Type Push Button, 22 Supply of 22.5 mm dia LED indicating lamps (red,yellow, blue), 23 Supply of 240VAC analog time switch for ON-OFF control of street light, L&t/Legrand make. 24 Supply of 3 pole power contactor type ML 2, 40A current rating , L&t/Legrand make. 25 Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250. 225mm sweep RPM 9001 1400(9) , EPC/Crompton make. 26 Opening the following Exhaust fan (1 Phase/3 Phase) /Stand Fan/Cabin Fan testing, checking, Re-winding by supplyingsuper enamelled copper wire of appropriate gauge, minalex paper, mica sheet, changing the loops, overhauling, becking, varnishing, re-fitting and testing and measuring r.p.m. etc.Cabin Fan (16 or 40 em, dia sweep), 27 Supply installation testing and commissioning of5.3 H.6 following capacity geyser 5 star rated storage water heater with advanced 3 level safety,For 25L-capacity Venus /any equivalent make. 28 Properly checking of the motor ( upto 75 HP), testing of developed IR value, load current factor, terminal lead joints, terminal bar etc. necessary repairing works. 29 S&F Water proof power supply system IP65, output volatge 12V/24V DC, 50/60Hz frequency, 108 to 305 VAC powersupply, >.95 power factor for LED lamp. (Make: Meanwell), 300 Watt, Model ELG 300. 30 Supply of Alpharex3 D22, 2 channels digital Time swiches,Cat.Nos-4126 41, Legrand make.
Contract Date: Aug 12, 2025 Contract Value : 14.13 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
4.
Defence #11413644 Technical Bid
Tender For Repair And Maintenance Of Chs Alongwith Connected Items At Various Units At Bhimbat,Thasgam & Drass Under Ge Kargil.- 1 Dismantling The Existing Burner Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed. 2 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr For De- Carbonization , Descaling And Refractory Cement And Assemble The Same And Testing Complete All As Specified And Directed. 3 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity 2 Lakh Kcal/ Hr By Using Brush And Vaccum Cleaner Complete All As Specified And Directed. 4 M&L For Descaling Of Boiler By Circulating The Descaling Chemical Using Circulating Pump Into The Boiler And Kept It For Approx 4 Hours For Descaling And Flushing Off The Chemical After Descaling Of Boiler Complete All As Specified And Directed. 5 M&L For Refractory Cement / Heat Resistance Cement Of Boiler Assembly Of Heating Plant Complete All As Specified And Directed. 6 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 20Mm Complete All As Specified And Directed. 7 Supply And Fixing In Replacement Of Solenoid Valve Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 8 S&F In Repair Of Photo Cell Sensor Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Make - Cofi Complete All As Specified And Directed. 9 S&F In Repair Hydraulic Pressure Gauge Showing Reading 0-20 Bar With Accuracy +/- 2.5% To Be Connected With 15 Mm Dia Gi Pipe Complete With Suitable Size Of Battery Complete All Accessories And Protection Cover. 10 S&F In Repair Digital Temperature Controller (Dtc) Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 11 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 12 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 13 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 14 S&F In Repair Of Nozzel 60 Degree Complete All As Specified And Directed. Make : Danfoss Or Equivalents Make. 15 Replacement Of Old Unserviceable Minor Part For The Control Panel Including Repairing Of Wiring Etc As Per Existing, Complete All As Specified And Directed By Engr-In-Charge. 16 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 17 S&F In Repair Thermostat Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 18 S&Fin Repair Sequence Controller Suitable For Burner Heating Plant Of Capacity 2 Lakhkcal/Hr Rapid Therm Boiler Complete All As Specified And Directed. 19 S&F In Repair Contactor 25A, 230V/440V Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 20 S&F In Repair Of Contactor 230/ 440V Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 21 S&F In Repair Relay 4.5 - 7.5 Amps, 3 Phase, 50 Hz, 415 Volts Suitable For 2 Lakh Kcal Boiler Rapid Therm Boiler Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 22 S&F In Repair Relay 6 - 10 Amps,3 Phase, 50Hz, 415 Volts Including Testing Complete All As Specified And Directed. Make-L&T / Abb / Schnider 23 S&F In Repair Diesel Filter Assembly With Drain Port Complete As Per Sample. 24 S&F In Repair Fuel Pipe For Burner As Per Sample. 25 M&L For Complete Rewinding Of Electric Motor Of Capacity 5 Hp 3 Phase 415 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 26 M&L For Complete Rewinding Of Electric Motor Of Capacity 1 Hp Single Phase 230 Volt With Super Enameled Copper Wire Of Superior Quality As Per Existing Gauge Including Varnishing, Insulating Material Complete All As Directed And Including Reassembling Fixing In Position Making Connection Testing, Commissioning & Transporting Complete All As Specified And Directed By Engr-In-Charge. 27 All As Per Item No 26 Above But Capacity 0.5 Hp Single Phase 230 Volts. 28 Repair Of Chimney 7Mtr High Complete With Welding Including Iron Pieces, Plates, Outlet Cover And Necessary Modification And Cleaning Complete Removal Of All Kinds Of Dust Both Internal And External Parts And Free From All Kind Of Dust/Dirty Spots Of Chimney, Complete All As Specified And Directed By Engr-In-Charge. 29 M&L For Elastomeric Nitrile Rubber Foam Insulation Sheet For Ducts Having Anti Microbial Properties Having Thickness 10 Mm With Suitable Adhesive Complete All As Specified. 30 Dismantling Of Unserviceable/Damaged Hepa Filters And Supply And Fixing Of Hepa Filters With Al Box And Flange Type Of Size 640 X 460 X 50 Mm With Frame Having Efficiency Of 3 Microns Complete All As Specified. 31 M&L For Cleaning Of Existing Hepa Filters With Pressurized Potable Water By Using Pressure Pump And Water Spray Gun, Dry The Filters With Compressed Air After Cleaning Complete All As Specified. 32 Supply And Topping Up Of Antifreeze (Coolant) Suitable For -35 To -40 Degree Celsius To Be Filled In Reservoir Tank For Central Heating System As Instructed By Engr-In-Charge. 33 S&F Of Threaded Thermometer Having Range -50 To +100 Degree Celsius With Accuracy +/-2.5% To Be Fixed On 15 Mm Dia Gi Pipe Complete With All Accessories. 34 M&L For Rewinding Of Ahu Blower Motor Cap 5 Hp And Testing After Repair Complete All As Specified. 35 M&L Charges For Servicing Of Air Handling Units Including Blower Cleaning, Balancing Of Blower Motor Pully Complete All As Specified. 36 S&F In Replacement Of Supply Air Diffuser Alongwith Collar Damper Of Size 600 X 600, Neck Size 450 X 4550Mm All As Specified. 37 M&L For General Maintenance, Inspection And Servicing Of Chiller Unit By (Make-Bluestar Model No. Xac2S-010R2) Cleaning Of Condenser And Evaporator Coils Of The Chiller Unit By Using Specialized Cleaning Solution And Pressure Washing, Inspections Of The Compressor And Water Pump For Leaks, Noise, And Proper Functionality, Verifying The Integrity Of Electrical Components, Including Wiring, Breakers And Sensors, Parts, Lubrication Of Moving Parts, Checking Of Any Refrigerant Leaks, Checking Performance Testing And Optimization. 38 M&L For Repair/Replacement Of Faulty Components, Fixing Any Refrigerant Leaks And Vaccum Testing And Performance Evaluation After Refilling, Replacement Of Worn Out Gaskets, Seal And O-Rings For Chiller Of Capacity 9.2 Tr Complete All As Specified And Directed. 39 Supply And Charging Of Refrigerant Gas R-407C As Per Existing For Chiller Of Capacity 9.2 Tr And Testing After Charging Complete All As Specified And Directed. 40 Supply And Topping Up Of Compressor Oil As Per Existing Grade Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 41 Supply, Installation, Testing In Replacement Of Hermetic Type Scroll Compressor Unit , Suitable For 9.2 Tr Capacity Chiller Unit (Make-Bluestar Model No. Xac2S-010R2) Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Bluestar/Godrej / Lg Or Equivalent. 42 S&F In Replacement Of Expansion Valve As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 43 S&F In Replacement Of Filters & Driers As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 44 S&F In Replacement Of Pressure Switches As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 45 S&F In Replacement Of Control Relays As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 46 S&F In Replacement Of Fan Motor Of Cooling Tower As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 47 S&F In Replacement Of Temperature Controller As Per Sample Suitable For 9.2 Tr Capacity Chiller Complete All As Specified And Directed. 48 Dismantling The Existing Burner Assembly Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr For Repairs And Replacement Of Coupling For Blower And Motor Of Burner Assembly And Refixing The Same Position Including Testing Complete All As Specified And Directed By Engr-In-Charge. 49 Dismantling The Existing Boiler Assembly Of Heating Plant Of Capacity 30000 Kcal/ Hr For De- Carbonization And Assemble The Same And Testing Complete All As Specified And Directed By Engr-In-Charge. 50 M&L For De- Carbonization Of Boiler Assembly Of Heating Plant Of Capacity Capacity 30000 Kcal/ Hr By Using Brush And Vaccum Cleaner Or Blower Complete All As Specified And Directed By Engr-In-Charge. 51 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Gun Metal Of Size 25Mm Complete All As Specified And Directed By Engr-In-Charge. 52 S&F In Repair Of Photo Cell Sensor Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/ Hr Complete All As Specified And Directed By Engr-In-Charge. 53 S&F In Repair Dtc Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 54 Supply And Fixing In Replacement Of Ignition Electrode Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 55 Supply And Fixing In Replacement Of Igintion Transformer Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 56 Supply And Fixing In Replacement Of Fuel Feed Pump With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 57 S&F In Repair Of Nozzel 60 Degree Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 58 S&F In Repair On/Off Selector Switch With Indicator Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 59 S&F In Repair Thermostat Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 60 S&Fin Repair Sequence Controller Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 61 S&Fin Repair Solenoid Valve Suitable For Burner Of Oil Fired Hot Water Boiler Of Capacity 30000 Kcal/Hr Complete All As Specified And Directed By Engr-In-Charge. 62 S&F In Replacement Of Chimney Exhaust Of 6 Inch Dia Made Of Auminium Sheet Including Bends And Outlet Cover Complete All As Specified And Directed By Engr-In-Charge. 63 Dismantling The Existing Radiator Unit Of Capacity From 3000 To 6000 K Cal Per Hour, Taking It To Nearest Workshop Cleaning The Complete Unit With Coil Shine Chemical, Detecting The Leakage Portion By Applying Nitrogen Gas Pressure, Brazing The Leakage Portion, Refixing The Same Unit From Dismantled Location Including Testing On Load Complete All As Directed At Site By Engineer-In- Charge. 64 Supply And Laying 3 Layer (Inner Antimicrobial, Outer Uv Stabilized) Isi Marked Is-15801 Pp-R Pipe And Pp-R Plain Fittings In Walls Or Laying In Floors Complete Of Size Outer Dia 25 Mm Including All Fittings (Surface Remitting Also Included). 65 S&F In Repair Of Ball Cock Valve Heavy Duty Made Out Of Brass Of Size 25Mm Complete All As Specified And Directed. 66 S & F In Replacement Thermostat Suitable For 126/165/195/310 Litres Capacity Refrigerators All As Directed. 67 Supply And Charging Of Refrigerant Gas As Per Existing For Refrigerator Of Capacity 126/165/195/310 And Deep Freezer Of Capacity 300/320/400/500 Ltr Capacity Including Testing After Application Of Nitrogen Gas Pressure To Find Out Any Leakage, Brazing And Stopping Of All Leakage Detected, Re-Application Of Nitorgen Pressure To Ensure Leak Proof Gas Circulator System Flushing Out The Nitrogen Gas Complete All As Specified And Directed. 68 S&F In Replacement Of Compressor Unit , Suitable For 165/195 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 69 S&F In Replacement Of Compressor Unit , Suitable For 126 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 70 S&F In Replacement Of Compressor Unit , Suitable For 310 Ltr Capacity Refrigerator Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete All As Specified And Directed . Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed. Make : Godrej / Lg/ Bluestar. 71 S&F In Replacement Of Copper Capillary Tube With All Fittings For Refrigerator Of Cap 126/165/310 Ltr Complete All As Specified. 72 Repair To Voltage Stabilizer For Automatic Operation Single Phase Naturally Air Cooled, Indoor Type Designed For Output Variation Between 170 To 250 V With Output Voltage Stablized At 230 V With Accuracy Of +/- 2.5 % And Capacity 1 Kva And Making Connection With Ac Complete All As Specified & Directed. 73 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 50 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 74 Supply And Fixing In Replacement Of Water Heater Storage Single Phase 230 Volt 25 Ltrs Capacity Bee 5 Star Rated And Grouting 4 Nos Nut & Bolts 90 Mm Long 12Mm Dia On Wall For Fixing And Connection Pipes Including Taking Out Old Unsv Geyser Complete All As Specified. Make : Havells / Crompton/Bajaj/Racold. 75 M&L For Replacement Of Unservicible Inner Shell Made Of Stainless Steel 1.5Mm Thick Suitable For Geyser Inclusive Of Glass Wool As An Insulating Material For Geyser Of Capacity 25-50 Ltrs. 76 M&L For Replacement Of Thermostat For Geyser 0 To 80˚ C Complete All As Specified And As Directed By Engineer-In-Charge. 77 M&L For Flexible Pvc Connection Pipe For Geyser Of Length 1.5 Feet As Per Sample. 78 M&L For Replacement Of Pressure Release Valve For Geyser Of 25 Ltr Having Size 15Mm Dia. 79 M&L For Replacement Of Heating Element For 25 Ltr Geyser Capacity Round Type 1.5 Kw As Per Sample. 80 M&L For Replacement Of Heating Element For 25 Ltr Cap Triangle Type 1.5 Kw As Per Sample. 81 M&L For Replacement Of Geyser Assembly Suitable For 25 Ltr Geyser As Per Sample. 82 Repair And Replacement Of Kerosine Oil Batti Including Blower, Burner For Hammam 500 As Per Sample Complete All As Specified And Directed. 83 S&F Brass Tap Size15/20 Mm For Hamam As Per Sample Complete All As Specified And Directed. 84 M&L For Replacement Of Heating Element As Per Sample Suitable For 500Ltr Hammam As Per Sample. 85 S&F In Repair Of Compressor New Sealed Unit, Suitable For 300/320 Ltr Capacity Deep Freezer And Testing On Full Load Including Brazing And With Necessary Nuts And Bolts, Copper Filter, Capillary Etc Complete In All Respect Complete All As Specified And Directed By Engr-In-Charge.Note: Compressor Will Be Purchased With Guarantee Period And Must Be Company Sealed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 16
Jammu And Kashmir View Result →
5.
Water Resources and Irrigation #11293228 AOC
Periodical and Emergent electrical maintenance under jurisdiction of Khatra Electrical and Water supply section during the year of 2025-26.- 1 Emergent Electrical maintenance work as & when required basis under the jurisdiction of Khatra Electrical & Water supply section i.e. KMD office, KC-II Div, Raipur Sub-div, Khalashi Shed, Kangsabati Upper and lower colony etc. under the jurisdiction of KMD. 2 a) Electrican 3 b)Helper for Electrician 4 Periodical and Emergent electricial maintenance work and pump operation for one year under jurisdiction of Khatra Electrical and Water supply section Khatra Electrical & Water supply section i.e. KMD office, KC-II Div, Kangsabati Upper and lower colony etc. 5 a) Electrican 6 b)Helper for Electrician 7 Opening the Ceiling fan testing, checking and Re-winding by supplying super enamelled copper wire of appropriate gauge, minilex paper, mica sheet, changing the loops, overhauling, backing, varnishing, re-fitting and using and measuring r.p.m. for ceiling fan above 36 sweep up to 60 sweep. 8 Supplying following sizes Capacitor of 250V rating: 2.5 MFD Capacitor (Universal Make or equivalent). 9 Supply Philips LED tube, model no : Mas LEDtube 1200mm 18W865 T8 I - 2100lm, 10 Supply of 2X20 T8 tube holder alongwith2 nos. 20 Watt T8 LED Tubes Specification T8 LED Tube , CCT-6500K, Lumen-2200, Make-Magik/ any, approved make. 11 Supply and fixing of smart bright essential street light complete with all accessories to be fixed / projected from the wall of the building or on pole incl. making holes/ providing clamping arrangement & necy. GI reducer as required. S&F 40mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. 72 watt with Toughend glass , 130 lm/w, Spd 15 kva at least and 5 years warrenty etc, Surya/ Crompton make. 12 Supply of Havells make, NU Bulb Plus 9W 865 B22 3 Star, 13 Supply of 6.0 sqmm FR stranded Copper wire, polycab/ Mescab /finolex, 14 Supply of 1.5 sq.mm FR stranded Copper Wire, Polycab/Mescab/finolex . 15 Supply of 5 A, piano key type Switch , Anchor/ havells . 16 Supply 5 A, 3 pin Piano flush type Socket Anchor/ havells. 17 Supply of Step Type Electronics Fan regulator, Anchor/ havells . 18 Supply of 16A kit kat rewireable fuse, havells/ standerd/ flora. 19 Supply of ammeter selector switch Current in Each phasewith OFF, 4 Pos. 90° angle of throw (OFF-R-Y-B). 20 Supply of voltmeter selector switch Votage between phaseswith OFF, 4 Pos. 90° angle of throw (OFF-RY-YB-BR). 21 Supply of 22.5 mm Hole Dia Mushroom Type Push Button. 22 Supply of 22.5 mm dia LED indicating lamps (red,yellow, blue) 23 Supply of 240VAC analog time switch for ON-OFF control of street light, L&t/Legrand make. 24 Supply of 3 pole power contactor type ML 2, 40A current rating , L&t/Legrand make. 25 Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250. 225mm sweep RPM 9001 1400(9) , EPC/Crompton make. 26 Opening the following Exhaust fan (1 Phase/3 Phase) /Stand Fan/Cabin Fan testing, checking, Re-winding by supplyingsuper enamelled copper wire of appropriate gauge, minalex paper, mica sheet, changing the loops, overhauling, becking, varnishing, re-fitting and testing and measuring r.p.m. etc.Cabin Fan (16 or 40 em, dia sweep), 27 Properly checking of the motor ( upto 75 HP), testing of developed IR value, load current factor, terminal lead joints, terminal bar etc. necessary repairing works. 28 Supplying of approved make high speed ceiling fan (ISImarked) of following sizes having double ball bearingcomplete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts 1200mm, Usha make. 29 Supply and delivery of direct on line ( DOL) strater panel board conforming to ISl3947 and IEC 947 of suitable HP rating for operation in 230V (+10%) AC, single phase, 50HZ(+5yo) comprising of ammeter, voltmeter, thermal overload relay,2 pole magnetic contactor, under voltage protection, indicating lamp, capacitors, on/off push buttons including 5 way connector, wiring with l/1.5 sq. mm PVC insulated copper wire, powder coated vermin proof box of following capacities:- 1.5 H.P. (Relay Range 9-14 Amp.) 30 Supplying and fixing 415V, TPN SFU open execution in existing SS enclosure/cubical with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. 200A, L&T make.
Contract Date: Aug 11, 2025 Contract Value : 9.66 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
6.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
7.
Rural Development #11250007 AOC
Tender for Providing, Erecting And Supplying Various Different Electric Material For 1 Year @Gr Anchayat Kadamwakwasti , Electric Material This Rate Please Mentioned Include Gst Invoice Shall Be Prepared With Gst Tax Whatever Applicable On Material Rate Are Mentione With Gst , Supplying And Erecting Modulartype Switch6a / 10A Isimark Approved Make Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying & Erecting Ms Pole Bracket For Guarding/Lt Oh Line, Fabricated From Angle Iron 50X50x6 Mm And 550 Mm Long For Necessary Nos. Of Provided Insulators And Erecting On Pole With 50X6mm Clamp Complete As Per Specification No. Oh -Pl/Bkt , Making Cement Concrete Foundation Including Excavation (60 X 60 X 150) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, (45 X 45 X 45) Cm /45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (Above 6 M To 9 M Poles) , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 6 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 139.7 X 114.3 X 88.9 Mm. Dia With 4.5X3.65X3.25 Mm Thickness (4.5 + 1.75 + 1.75M) Length Respectively And Total 8 M Long With Pole Cap, Base Plate In Provided Foundation.(Weight 101 Kg.) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm. Dia With 4.5 X 4.5 X 3.65 Mm Thickness ( 5 + 2 + 2M ) Length Respectively And Total 9 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 147 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia With 4.5 X 4.5 X 3.65 Mm. Thickness (5 + 2.5 + 2.5 M) Length Respectively And Total 10 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 160 Kg) As Per Specification No. Oh-Pl/Stp , Supplying And Erecting Steel Tubular Swaged Pole 165.1 X 139.7 X 114.3 Mm Dia. With 4.5 X4.5 X3.65 Mm Thickness (5.60 + 2.7 + 2.7 M) Length Total 11 M Long With Pole Cap, Base Plate In Provided Foundation (Weight 175 Kg.) As Per Specification No. . Oh-Pl/Stp , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting On Tubular Welded Pole With 40 Mm. Dia 1.0 M Long B Grade G.I. Pipe Along With Pole Cap Of 125Mm Dia 600 Mm Long Duly Welded As Per Specification No. Fg-Bkt/Bpc , Supplying, Erecting & Marking Dpmcb 40A To 63A, B- Series (For Lighting) In Provided Distribution Board As Per Specification No. Swswr/Mcb , Supplying And Erecting Insulated D.P. Switch Surface Type/Flush Type 32A 240Vwith Indicator Lamp & Fuse , Supplying And Erecting Programmable Digital Almanactimer Microcontroller Based With Real Time Clock To Operate On Derived Switching On & Switching Off Street Light As Per Daily Sunset And Sunrise Respectively , Supplying Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm (30 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm (50 No. X 0.25 Mm Dia.) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erectingled Street Light Fitting Suitable For 26W To 36W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting Suitable For Above 40W To 48W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification No Bajaj. Fgodf/Fls2. , Supplying And Erecting Led Street Light Fitting Suitable For 60W Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete As Per Specification Bajaj No Fg Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting Suitable For Above 70W- 75 Lamp, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls2 , Supplying And Erectingled Street Light Fitting Suitable For 90 W Led Street Light, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Alluminium Alloy And Heat Sink Bajaj , Supplying And Erecting Led Street Light Fitting 100W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 120 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2. , Supplying And Erecting Led Street Light Fitting 150 W, Including Lamp, With providing fixing 0.95 Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Led Flood Light Fitting Of 120W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg Odf/Fls-2 , 2-5-17 Supplying And Erecting Led Flood Light Fitting Of 150W, Including Lamp, With providing fixing 0.95,Class Ip 65 And Above Housing Of Pressure Die Cast Aluminium Alloy And Heat Sink Extruded Aluminium Complete Per Specification Bajaj No Fg-Odf/Fls-2 , Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B Class G.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification Jno. Fg-Bkt/Bpc(2-9-2) , Supplying And Erecting Street Light Wall Bracket Made From 25 Mm. Dia ‘B Class G.I. Pipe 1.2 M In Total Length Complete As Per Specification No. Fg-Bkt/Wb(2-9-3) , Supplying & Laying Pvc Armoured Cable 4Core 6Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 10 Sq Mm 7-1-15 , Supplying & Laying Pvc Armoured Cable 2Core 10 Sq Mm , Supplying & Laying Pvc Armoured Cable 2Core 6 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 16 Sq Mm , Supplying & Laying Pvc Armoured Cable 4Core 25 Sq Mm , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 70 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 95 Sq. Mm. Aluminium Conductor , Supplying, Erecting & Terminating Xlpe Armoured Cable 3½ Core 120 Sq. Mm. Aluminium Conductor With Continuous , Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series (For Lighting) , Supplying, Erecting & Marking Dpmcb 6 A To 32 A Bseries (For Lighting) , Supplying, Erecting & Marking Fpmcb 40A To 63A In Provided Distribution Board , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Upto 16 Sq Mm Complete , Supplying & Erecting Crimping Type Coper Lugs For Cable Upto 1.5 To 6Sq Mm Complete... , Supplying And Erecting Two Pole Power Contactor 250V 32A For Time Switch Complete Erected On Wooden Block/Provided Box, With Necessary Materials. , Supplying & Erecting Mains With2x1.5 Sq.Mm F.R Copperpvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole , Supplying & Erecting Mains With 2X4 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit/Trunking/Inside Pole/Bus Bars Or Any Other Places. As Per Specification No: Gma/Bw , Supplying And Erecting Mains With Isi Mark Wp2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg 1-4-3 , Supplying And Erecting Mains With Isi Mark Wp2 X 2.5 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , Supplying And Erecting Mains With Isi Mark Wp2 X 10.00 Sq Mm. 1100 V. Grade Aluminium Pvc Insulated Pvc Sheathed Wires On G.I. Bearer Wire , 25 Amp, 32 annual periodical maintenance Three Phase L/T Contactor , Insulation Tape , Water Proof Tape , Cable Joint Kit Upto 25 Sq. Mm Cable , Cable Joint Kit Upto 35Sq. Mm To 95 Sq Mm Cable , Cable Joint Kit Upto 120Sq. Mm To 185 Sq Mm Cable , Cement Street Light Pole Clamp With Nut Bolt , M.S. Street Light Pole Clamp With Nut Bolt , Servicing And Primary Maintenance Of Street Light Pole 1 Visit Per Month Pole Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection. Old Light Changing & Service Wire Conection Labour Works Etc. , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes(Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Servicing And Primary Maintenance For Street Light Pole. , Light Poles Painting In Silver Colour , 26W Led Light To 100W Led Light Repairing , Old Pole Shifting, Rework And Foundation Work Per Pole Etc. , Supply &Fixing Of Shakle Hardware With Nut Bolt , Supply And Installation Of Mini Feeder Pillar With Stand , Reinforced Cement Concrete Road Cheasling Charges With Tractor Breaker (1 Hours) , Tree Triming For Overhead Line , Supplying & Erecting Street Light Control Panel Outdoor Type, For Single Phase 2 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 2 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete. , Supplying & Erecting Street Light Control Panel Outdoor Type, For Three Phase 4 Wire System Having In Built Astronomical Adjustable Programmable Timer With Minimum 5 Years Battery Backup, 4 Pole Contactor Upto 60 A, With Maintenance Mode To Switch On Street Lights During Time Of Repairs With Energy Consumption Data Recording For Analysis And Lcd Display For Energy Monitoring With Numeric Key Pad In Provided Box Complete , Servicing And Primary Maintenance Of Solar Light Pole 1 Visit In Month Included And Also Call Basis. Checking All Wire Connections, Nut Bolt Tighting, Lugs Connection, Timer Working Condition And Panel Cleaning , Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 9 W Led Fitting, 12V 18Ah Maintenance Free Lithium Battery, Min. 40 Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esd-Sol-Stl ( With 5 Years Warrantee ) , 4-3-13 Supplying, Installing, Testing And Commissioning Solar Street Light Pole Comprising Of 12W X 2 Nos. Led Fittings, 12V Min. 100Ah Maintenance Free Lithium Battery, Min. 120Wp Spv Module, Ms Powder Coated Battery Box Weather Proof, Mounted On 75/80 Mm Dia. B-Grade Gi Pole Of 6 M. Height Along With Brackets, Foundation, Earthling And Necessary Accessories Complete. Specification No. Esdsol-Stl , Providing Rental Basis Hydraulic Bucket Vehicle Of Highth 13 Mtr. And Weight Capacity 200 Kg With Driver, Oprator And Disel Etc. For Per Day Basis.. , Providing & Erecting 7 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 130 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No.Oh-Pl/Opl. , Providing & Erecting 9 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 155 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 10 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 175 Mm A/F, Top 70 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Providing & Erecting 11 M High (Clear Height) Galvanised Octagonal Pole With Foundation Bolts Having Bottom Of 210 Mm A/F, Top 90 Mm A/F On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Opl , Supplying And Erecting Outdoor Stand Mounted Feeder Pillar For Highmast Of The Same Manufacturer With 63A Tpn Mcb Incomer, Single Dial Timer Switch, 45A Tp Contactor For Automatic Switching Of Luminaries, 2 Nos 9A Contactors And Raise/Lower Push Button, And Provision For Termination Of Adequate Size Of Incoming And Outgoing Cables Erected In Min. 14 Swg Crca Sheet Box Powder Coated With Supporting Angles, Self-Lock, Gasket And Slanting Top Erected With cement concrete Foundation Complete , Supplying And Erecting 12.5 M (Clear Height) High Mast (Top 150Mm, Bottom- 360Mm) With Lowering And Raising Motorized Unit, Lantern Carriage Assembly Suitable For Max. 6 Nos. Luminaries And Its Control Gear Box, Lightning Finial Arrangement For Fixing Aviation Light And Foundation Bolts On Provided Foundation As Per Specification Bajaj No. Oh-Pl/Hm (Excluding Luminaries ). , Making Cement Concrete Foundation Including Excavation (60 X 60) Cm X Deep 1/6 Of Pole Length In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, 45 Cm X 45 Cm X 45 Cm /45 Cm Dia. X 45 Cm. Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. (For Above 9 M Poles) , Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Fpmccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation As Per Specification No. Sw-Swr/Mfp , Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14/16 Swg Sheet, Outdoor Type, Single Phase, 240 V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Spn Mcb 63 A Auto/Manual Selector Switch,On/Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / cement concrete Foundation Complete. , Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep , Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials As Per Specification No. Ea-Ep , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 600Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying And Erecting Regular/ Standard Model Ceiling Fan Of 900 /1050 Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn/Cf , Supplying & Fixing Anchor Type Fastener Fan Hook, With 2 Nos. Of 10 Mm Dia X 75 Mm Long With Necessary Materials For Ceiling Fan. , 36 Watt Pcb , 36 Watt Driver , 50-60 Watt Pcb , 50-60 Watt Driver , 70 Watt Pcb , 70 Watt Driver , Highmast Repairing 100-150 Watt , Service Wire 4 Sq.Mm Isi Mark 2 Core , Service Wire 6 Sq.Mm Isi Mark 2 Core , Service Wire 10 Sq.Mm Isi Mark 2 Core , Frp Box Of Size 300 X200 X125 Mm 2.7Mm Thickness , 12W Led Bulb , 14W Led Bulb , 18W Led Bulb , 100 W Bulb , 200 W Bulb , 35 annual periodical maintenance Kitkat Fuse , 63 annual periodical maintenance Kitkat Fuse , Servie Reel Pvc , Retrofit T8 Led 18/20 Tube Light , Lamp Holder China Clay , Lamp Holder (Pendent) , 5Am Shocket Armor , 5Am Sawich Armor , Miter Box Singal Phase Pvc 300X150x420 , Miter Box 3Phase Pvc 540X600x200 , Miter Box Coted , 8M Sarfes Box & Pleat , Rsj Pole 9 Mtr , V Cross Arm 22 Kv , Cut Pont Set 22 Kv , Pin Insulater22 Kv , Disc Insulater 22 Kv , Nut Bolt , Conductor 55 Sq Mm Aac , Ht Stay Set , Lt Stay Set , Stay Wire , Gi Wire 8 Swg , Pole Errection , Conductor Errection , V Cros Fixing , Cutpoint Fixing , Mcb Box Metal 3Way , Supply Of Tiranga Pole As Per Sepcifucation 139.7Mm Od Pipe - 3Mtr 114.3Mm Od Pipe 1Mtr - 03 Nos 88.9Mm- Od Pipe - 2 Mtr Total 8 Mtr Pole , Day &Night Motin Sensor Auto On/Off Light Electronics(With Drayvar) , 9 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 6 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 6 Nos. E) Solar Panel Should Be Of 330 Watt --- 6 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , 6 Mtr. Pole Solar High Mast System: A) Solar Led Luminaries / Flood Light Wattage Should Be Of 50 Watt -- 4 Nos. B) Led Should Be Of/Powered By Philips/ Osaram Or Equivalent Reputed Brand. C) Battery Should Be Of Lithium Ion / Li Sepo4 (Lithium Ferro Phosphate) D) Battery Capacity Should Be Atleast 100 Ah --- 4 Nos. E) Solar Panel Should Be Of 330 Watt --- 4 Nos. F) Pole Should Be Polygonal. The Mast Should Be Hot Dip Galvanized 20 , Gst Charges
Contract Date: Jun 08, 2026 Contract Value : 14.78 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
8.
Power #11237449 AOC
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Residential; 2755929; Service Provider - Operation And Maintenance Of Water Treatment Plant Having One Flash Mixer With Agitator And Clarification Tank Having Rotating Bridge, Two Filter Beds, One Chemical House Having Two Alum Solution Tanks With Agitator, 132 Kl Overhead Tank, One Sump Well And Its Pumps Motor Filter Water Sump And 1To 3 Nos Pumps And Motor Upto 30 Hp, 2 Nos Pumps And Motor Upto 60Hp, And All Other Accessories Including Cleaning Of Clarification Tank , Filter Water Reservoir Tank 2 Nos With Site Pit And Out Side Back Wash Pit Including Cost Of All Labour T&P , Cost Of All Consumables Such As Grease, Lubricating Oil, Mobil Oil, Gear Oil, Packing Seat, Coupling Of Gear Box , Gland Dori Etc. Required For Proper Completion Of Work. Work Includes The Up Keeping And Cleaning Of Surrounding Area Of Filteration Plant, Daily Collection Of Treated Water S Le From Filteration Plant And Submitting The Same To Chemistry Lab Of 2X210mw For Testing And Collection Of Report And Maintaning The Test Register. Work Also Includes The Watch & Ward Of The Filtration Plant Complax Round The Clock And Daily Cleaning/Dusting Of All Equipments Fixed At Filteration Plant As Pump, Motors, Main Switches, Starters Etc. And Disposal Of Debries Out Side The Periphery Of Filtration Plant. , Operation Of Tube Well Daily By A Suitable Experienced Operator Continuously Or In Different Intervals As Per Program Fixed By Engineer-In-Charge Including Opening And Closing Of Valves, Greasing Of Motor, Changing Of Fuse Wire Etc. As Required For Proper Running Of Tube Well/Pump Set Of 15 Hp Inside Power House Area (Store Area). , Operation Of Over Head Tank 190 Kl And Pump House Near Type-Ii Area (Near Ministrial Club) As Required Including All Valves, Indicator And Cleaning Of Stairs, Structure And Area Inside Boundary Wall And Its Watch And Ward 24 Hrs. Daily. , Operation Of Pump Set Of 15 Hp And Tubewell Near Inter College Area (Type Iii) As Required Three Times Daily , Re-Winding Of Ac Mono Block, 3 Phase Motor, With Best Quality Insulating Material, Including All Charges Of Dismantling Of Motor And Its Pertaining Items Such As Suction And Delivery Pipes If Required And Stacking In Departmental Store And Including All Charges For Re Fixing Of Motor And Also Fixing Of Motor At Any Tube Well/ Pump House As Per Direction Of Engineer- In -Charge, Including Supply And Fixing Of All Material Like Nut, Bolt, Washer Packing Welding Grinding Of Shaft Etc. And Testing Of Motor Etc. All Complete . All Waste Material Like Burnt Wire Shall Be The Property Of The Contractor.3 Hp To 5 Hp , 7.5 Hp To 10 Hp , 15 Hp , Same As Item No 5 But Rewinding Of Submersible Motor Of Following Pump.1 Hp To 3 Hp , 5 Hp To 7.5 Hp , Repairing Of Following Submersible Pump Including All Charges Of Dismantling Pump And Its Purchasing Item Such As T&P Etc.1 Hp To 3 Hp , 5 Hp To 7.5 Hp , Providing & Fixing Of Bearings S.K.F. Or Nbc (From Main Distributor Produced With Orignal Cash Memo) Equivalent Make Including Removing Of Bearing From Pump/Motor Including Cost Of All Labours Material, T&P Etc. All Complete, 3 Hp To 5 Hp , 7.5 Hp To 10 Hp , 15 Hp , Supply & Filling Of 16/30 Gauge Approved Ram Nager Betwa Sand In Filter Bed Of Filtration Plant Situated In Colony Area Of Parichha Thermal Project, Parichha. , Taking Out Of Gear Box Fixed A Colony Water Treatment Plant Rotating Bridge, Opening Its Nut & Bolts, Replacement Of Gear Oil Big Oil Seal No. (Kds/1335/P25 Die 175.3), Small Oil Seal No. Kds-2705, Including Packing , Oiling, Tightening Of Nut & Bolts And Assembling , Reerecting , Repairing The Same On Bridge With Flocculate Or Rotating Bridge Including Making Proper Alignment With All Required Arrangements Including The Cost Of All Material, T&P Etc. Required For Proper Completion Of Work. , Repair Of Warm Shaft And Gear Of Gearbox Of Suitable Make By Filling Of Required Type Of Material Over Gear And Shaft (Warm Shaft) And Cutting Grove, Thread Etc. Over If On The Lathe Machine As Per Specification. Including The Cost Of All Material, T&P, Carriage Etc. Required For Proper Completion Of Work. , Same As In Item No 17 Above But For Providing And Fixing Of Rotating Shaft , Providing Fixing Of Thrust Bearings S.K.F. Or Nbc Make Of Approved Quality For Reduction Gearbox Of Approved Make And Including Removal Of Old Bearing, Checking Of Bore Size Inner And Outer And Fixing It In Proper Alignment Including Cost Of All Labours Material, T&P Etc. All Complete, For Warm Shaft (Gear Shaft) , For Rotating Shaft. , Opening Out Complete Assembly Of 25 Hp Pump And Column Pipes Fitted Of The Pump House Near 450 Kl Over Head Take, Repairing And Re-Fixing Including Other Cost Of All Material Such As Rubber Bush Bearing, Nut Bolts And Gland Plate Etc. Machinery Work, Grinding, Cutting Threading, Transportations Etc. If Required And General Over Hauling Of Complete Pumps For Proper Completion Of Work. , Same As In No. 21 Above But For 30 Hp Pups Installed At Colony Filtration Plant. , Supply And Fixing Of The Following Starter L&T Or Other Equivalent Approved Make For Following Motors., 5 Hp Ml-1 , (7.5 Hp-10) Ml-2 , (15 Hp-20 Hp) Ml-2 , Above 20 To 25 Hp Ml-2 , Providing And Fixing Of Bush Of Approved Quality For 5 Hp To 15 Hp Pumps Including The Cost Of All Labour Involved For Opening Out & Re Fixing Of Bush In Pumps And T&P Etc. For Proper Completion Of Work. , Cleaning Of Over Head Tank 450 Kl Capacity Of 28 Meter Staging, Removing & Cleaning Of Silt Mud Sludge Etc, And Its Disposal At Ground With In 30 M Lead And Washing Inside The Tank Disinfecting The Bottom Surface And Walls Of The Tank With Water, Containing Bleaching Powder Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. , Same As Above In Items No.28 But For 100 Kl To 190 Kl Capacity Over Head Tank Of 15 To 20 Meter Staging , Same As Above In Items No.28 But For 50 Kl To 150 Kl Capacity Under Ground Water Tank. , Supply And Fixing Of Gland Plate For Upto 10 Hp Water Pump Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. , Repair Of Starter For Electric Motor, Opening Out , Choking , Changing Its Oil, Minor Parts Such As Nut, Bolts, Washer, Damaged Contacts And Other Parts Required Including Of All Material, T&P Etc. Required For Proper Completion Of Work.(Cost Of Relay Sale Be Paid Extra As Per Actual) , Providing And Fixing (150 Mm Dia To 200 Mm Dia) Non Return Value (Nrv) Isi Make Of Approved Quality Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work.(With Minimum 6 Months Guarantee.) , Providing And Fixing Brass/Gunmetal Impeller For 30 Hp Vlt/Turbine Pump Installed At Filtration Plant In Colony Area As Per Details Given Below And As Per S Le. Including Supply Of All Material Like Seal Ring Lock Vollet , Bearing Coupling , Bush Packing, Nut, Bolt And All Other Material, T&P Etc. Required For Proper Completion Of Work. Make Warthanth/ Jonston /Jyoti, Capacity 180 M3 /Hr , Speed 1460 Rpm Head , 30 M) , Providing And Fixing Of Impeller For The Following A.C. Mono Block Pumps Of Kirloskar Or Other Approved Make Including Supply Of All Material, T&P Etc. Required For Proper Completion Of Work. 5 Hp To 7.50 Hp , 10 Hp To 15 Hp , Providing And Fitting The Following Items Upto 15 Hp Ac Mono Block Pumping Set All Material, T&P Etc. Required For Proper Completion Of Work With Pvc Cooling Fan Of Approved Quality. , P/F Key Way Of Coupling , Re-Metallising Of Bearing Seat On Rotarshaft And Machining , P/F Terminal Plate. , P/F Cooling Fan Cover Of Motor. , P/F Terminal Box Of Motor. , Replacing Of Set Of Main Contact Of Starter (L&T) Make Of Isi Mark Including The Cost Of All Labour, Material And T&P Etc. Required For Proper Completion Of Work. , P/F Of Condenser Of 45 Mfd Isi Mark For 2 H.P. Single Phase 230 V.A.C. Starter. , Repairing Of Following Sluice Valve Including Opening Out And Refixing Of Sluice Valve Accessories Such As Nut, Bolt, Glane, Repaired Spendil Etc. Including The Cost Of Machinery Arrangement, Nut, Bolt, Packing Etc. All Complete.(Min. Three Months Guaranty) Filling Required Type Of Metal Over Spindle And Gutka For Spindle And Machining Cutting Threading Over Spindle Its Clearing Of Rod On Lath Machine And Gutka Fixing In Spendil Etc. Or Replacement With New One (Old Material Will Be Property Of Contractor) And Re-Fixing Of All Accessories Including All Cost And Labour Material, T&P Etc. Required For Proper Completion Of Work.80 Mm Dia , 100 Mm Dia , 150 Mm Dia , 200 Mm Dia , 250 Mm Dia , 300 Mm Dia To 400 Mm Dia , Filling Required Type Of Metal Over Sluice Valve Seat Both Sides Including Cutting , Grinding, Welding , Fixing , Of Nut , Bolt, Washer In Sluevalve If Required Including Of Cost Of All Labour Material, T&P Etc. Required For Proper Completion Of Work.80 Mm Dia , 100 Mm To 125 Mm Dia , 150 Mm Dia To 250 Mm Dia , 300 Mm To 400 Mm Dia , Providing Cotton Mosquito Proof Net Covers To Water Beds Of Filter Plant Of Size Approximate 6.20X4.0X0.90 M Doubly Stitched From Inside And Outside With Minimum 25 Mm Wide Cotton Strip Including Cost Of Material Labour, Cartage, Taxes T&P Etc. Complete. , Hiring Charges Of Breaker Including Cost Of Tractor,Operator Deisel ,Lead Upto 50 Meter And All T&P Required For Execution Of Work. , Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : 25 To 40 Mm Nominal Bore , 50 To 80 Mm Nominal Bore , Providing And Fixing G.I. Pipes Complete With G.I. Fittings Including Trenching And Refilling Etc External Work, 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , 125 Mm Dia , 150 Mm Dia , Same As Above In Item No. 5 But Without Excavation, 15 Mm Dia , 20 Mm Dia , Providing & Fixing Of G.I. Reducing Socket For ‘B Class Pipe Of Following Dia Including Supply Of All Material, Labour T&P Etc. Complete. 20 X 15 Mm Dia , 25 X 20 Mm Dia , 50 Mm To Any Smaller Size , 65 Mm To Any Smaller Size , 80 Mm To Any Smaller Size , 100 Mm To Any Smaller Size , Dismantling G.I. Pipes (External Work) Including Excavation And Refilling Trenches After Taking Out The Pipes, Manually/ By Mechanical Means Including Stacking Of Pipes Within 50 Metres Lead As Per Direction Of Engineer-In-Charge, 15 Mm To 40 Mm Nominal Bore , Above 40 Mm Nominal Bore , Supply And Fixing Of G.I. Tee For Class B Pipe Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete. 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , Supply And Fixing G.I. Bend/Elbow Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete. 15 Mm Dia , 20 Mm Dia , 25 Mm Dia , 40 Mm Dia , 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , 100 Mm Dia , Providing And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes;75 Mm Diameter , Same As Above But 110 Mproviding And Fixing On Wall Face Unplasticised Rigid Pvc Rain Water Pipes Conforming To Is : 13592 Type A, Including Jointing With Seal Ring Conforming To Is : 5382, Leaving 10 Mm Gap For Thermal Expansion, (I) Single Socketed Pipes;110 Mm Diameterm Outer Dia , Providing And Fixing 110X25 Mm Outer Dia Pvc Saddle Or 110 Mm Outer Dia Pvc Including Rubber Ring Including All Excavation, Refilling The Trenches Including Cost Of All Material Labour T&P Etc. , Providing And Fixing Pvc Flange Tail Piece For 110/90 Mm Outer Dia Pvc Pipe Line , Providing And Fixing C.I. Sluice Valves (With Cap) Complete With Bolts, Nuts, Rubber Insertions Etc. (The Tail Pieces If Required Will Be Paid Separately) :100 Mm Diameter Class I , 150 Mm Diameter Class I , Providing And Fixing G.I. Union In Existing G.I. Pipe Line, Cutting And Threading The Pipe And Making Long Screws Including Excavation, Refilling The Earth Or Cutting Of Wall And Making Good The Same Complete Wherever Required : 15 Mm Nominal Bore. , 20 Mm Nominal Bore. , 25 Mm Nominal Bore. , 50 Mm Nominal Bore. , Repair Of Leakage In G.I./C.I./M.S./Pvc Pipe Line Of 20 Mm Dia To 200 Mm Dia Including Necessary Excavation Dismentalling And Relaying Of Pipe And Refilling Of Trenches Also Including Supply And Replacement Of Nuts/Bolts Washes Socket Flange Tail Piece, Spun Yard Safeda Welding Etc. Complete. 20 Mm Dia To 40 Mm Dia Pipe Line , 50 To 125 Mm Dia , 150 To 200 Mm Dia , Repair Of Reflex Valve By Removing It From Pipe Line Or Section And Of Pumping Set From Any Tube Well Opening Its Nuts And Bolts Replacing The Rubber/Leather Washer Making It Water Tight By Lightening Of Nuts And Bolts Reerecting/Refixing The Same In Pipe Line On In Tube Well Suction And Including Cost Of Job For Diameter Ranging From 100 Mm To 200 Mm Dia Including Taking Out Suction Pipe Of Required. , Supplying And Fixing Of G.I. Tee For Class B Pipe Of Approved Quality Including Cost Of All Material Labour T&P Etc. Complete.40X40x15/20 Mm Dia , 50X50x15/20 Mm Dia , Providing And Fixing 100 Mm Dia C.I. N.R.V. I.S.I. Marked Approved Quality Including Cost Of Al Labour, T&P Etc. Required For Proper Completion Of Work , Supply Of D Joint Of Following Dia Including Cost, Cartage Etc. Complete. 65Mm To 80 Mm Dia , 100 Mm Dia , 150 Mm Dia , Dismantling Manually/ By Mechanical Means Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50Metres Lead As Per Direction Of Engineer-In-Charge : Water Bound Macadam Road , Bituminous Road , Cleaning Jungle Including Uprooting Of Rank Vegetation, Grass, Brush Wood Trees And Saplings Of Girth Up To 30 Cm Measured At A Height Of 1 M Above Ground Level And Removal Of Rubbish Up To A Distance Of 50 M Outside The Periphery Of The Area Cleared. , Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality (Screwed End) : 25 Mm Nominal Bore , 50 Mm Nominal Bore , 65 Mm Nominal Bore , 80 Mm Nominal Bore , Providing And Fixing Ball Valve (Brass) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete,15 Mm Nominal Bore , 20 Mm Nominal Bore , Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth. 1.5M In Width As Well As 10 Sqm On Plan) Including Disposal Of Excavated Earth, Lead Upto 50M And Lift Upto 1.5M, Disposed Earth To Be Levelled And Neatly Dressed. , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering - All Work Up To Plinth Level : 1:2:4 (1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size) , 1:4:8 (1 Cement : 4 Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). , Brick Work With Common Burnt Clay F.P.S. (Non Modular) Bricks Of Class Designation 7.5 In Foundation And Plinth In: Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) , Structural Steel Work Riveted, Bolted Or Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete: , 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 Fine Sand) , Providing And Fixing Brass Stop Cock Of Approved Quality Weight Not Less Than 400 Gram. 15 Mm Nominal Bore. , Attending To Petty Maintenance Services Like Plumbing, Welding, Carpenting, Mason With One Carpenter Plumber Or Mason And One Helper Per Hour , Dewatering By Pump Of Capacity 5/7.5 Hp With 4 Meter Sump And 50 Meter Pump Length Including Installation, Operator/Helper, Desiel/Fuel Etc As Per Direction Of Engineer In Charge.
Contract Date: Ref. Documents Contract Value : 36.48 Lakh
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
9.
Defence #11225622 AOC
Bids Are invited for Consultancy And Soil Investigation Soil Investigation 1 - Carrying Out Soil Investigation Incl All Necessary T&P Labour And Required Materials Etc All Field Work Collection And Interpretation Of Data And Laboratory Studies And Submission Of Report Comprising Of The Following , Soil Investigation 2 - Mobilization Of Plants And Equipment Including Men And Materials As Required At Site Of Soil Investigation Setting Of Boring Drilling As Required And Demobilization Of Plants And Equipments On Completion Of Work Etc Complete Which Includes Conveyance Of S Le Collected To Testing Lab As Reqd For The Purpose Of Testing , Soil Investigation 3 - Boring 150Mm Dia Bore Holes To Any Depth Through Following Type Of Strata , Soil Investigation 4 - Any Type Of Soil , Soil Investigation 5 - Soft Rock , Soil Investigation 6 - Hard Rock , Soil Investigation 7 - Collection Of Undisturbed Soil S Les At Every 3M Intervals Or At Any Change Of Strata In 100Mm Bore Thin Walled Tube Including Waxing Sealing Packing Transporting To The Lab , Soil Investigation 8 - Carrying Out Standard Penetration Test Spt As Per Is 2131 Including Collection Of Disturbed Soil S Les In Bore Holes At Every 5M Depth Or At Any Change Of Strata And Submit The Report With All Requisite Data , Soil Investigation 9 - Conducting Necessary Test On All Collected S Les Of Each Bore Hole Which Includes The Determination Of , Soil Investigation 10 - Atterberg Limits Natural Moisture Content Wet And Dry Density Soil Particle Size Using Sieve Hydrometer Analysis And Shear Strength Test Unconfined Compression V Tri-Axial Shear Test C & Determination Shrinkage Limit Consolidation Test Incl Pre-Consolidation Pressure Specific Gravity Test For Sand Rock Crushing Strength Of Rock S Le Permeability Test Testing Of Water S Le Including Ph Determination 02 S Le Free Swelling Index Soluble Salt Content Chloride And Sulphate Shear Strength Test Un Confined Compression , Soil Investigation 11 - Complition And Analysis Of Laboratory And Field Test Results And Submission Of Reports In 04 Sets Alongwith Recommendations For Seletions Of Type Of Foundation With Supporting Design Details And Recommendation Of Sbc Etc Complete , Consultancy 1 - Consultancy Services For Preparation And Supply Of Architectural Drawing Plan Section And Elevation Structural Design Preapration Of Boq And Estimate Rate Analysis For Provn Of Consultancy Work For Extension Of Rcc Varandha Alongwith Rcc Roof For Airmen Billet At Lambaline Af Stn Sri Vijaya Puram Consisting Of Following Scope Of Works , Consultancy 2 - Preparation And Submission Of Self Sufficient Structural Design And Drawing Including Structural Details Structural Notes Conforming To Is 456 And Is 816 And Is 875 And Is 1893 And Is 2062 And Is 4326 And Is 13920 And Is 2911 And Any Other Latest And Relevant Is Code , Consultancy 3 - Third Party Vetting & Proof Checking The Consultant Shall Be Responsible For Third Party Vetting Or Proof Checking From Iits Or Nits Or Any Government Engineeering College Duly Signed By Authorised Signatory On Behalf Of The Institute And Not From A Professor Or Individual Of The Institute In His Personal Capacity. The Design Drawings Shall Also Be Liable For Ensuring That The Design And Drawings Are In Compliance As Per Laid Down Standards Regulations Adherence To Is Specifications And Sound Engineering Practices The Consultant Is Responsible For Obtaining Clarification From The Vetting Agency Till The Completion Of Work A Certificate That All Details Have Been Thoroughly Checked And Are In Compliance To Standards Codes Regulations In Respect Of Safety Soundness And Economy Shall Be Obtained From Vetting Agency Total Quantity : 43
Contract Date: Ref. Documents Contract Value : 3.45 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
Andaman And Nicobar Islands View Result →
10.
Water Resources and Irrigation #11223260 Price Bid
Tender for Repair Of Control Panel And Providing/Fitting Of Foot Valve Of Priming Pump Along With Allied Works At Lis Khawas Khan. , Repair And Reconditioning Of Existing 125 annual periodical maintenance Lt Control Panel Of 415 Volts, Ac 3 Phase, 50 Hz At Lift Irrigation Station Khawas Khan Serving 2 Nos. Motors Of 20 Hp Each By Way Of Replacement Of Faulty/Non-Functional Multispan Mpd 192 (Or Equivalent Isi Standard Make) Motor Protection Device/Fault Analyzer After Extracting The Old Damaged One By Way Of Disconnecting All The Existing Wiring Connections At Its Terminals And Removing It From The Panel Enclosure. providing and Fixing Of New Multispan Mpd 192 Or Equivalent Protection Relay In Its Place And Reconnecting All The Control Wiring As Per The Original Wiring Scheme. Setting/Configuration Of The New Protection Device For 20 Hp Motor Parameters Including Overload Threshold, Underload/Dry Run Detection Level, Over/Under Voltage Limits, Phase Unbalance And Earth Leakage Settings As Per Motor Nameplate Data. Replacement Of 3 Nos. Existing L&T Mnx 25 (25 Amp) Air Break Contactors Of The Star Delta Starter Of Motor No. 1 Which Are Undersized For 20 Hp Motor Rating With 3 Nos. New L&T Mnx 40 (40 Amp) Or Equivalent Isi Standard Make Air Break Contactors Comprising Of 2 Nos. 40 annual periodical maintenance Contactors For Main And Delta Duty And 01 No. 40 Contactor For Star Duty After Extracting The Old Undersized Contactors By Way Of Disconnecting The Power Cables And Control Wiring And Removing The Old Contactors From Their Mounting Arrangement. Reconnecting All Power Cables Of Adequate Current Carrying Capacity And Control Wiring To Appropriate Terminals Of The New Contactors As Per The Star Delta Circuit Including Interlocking Connections Between Star And Delta Contactors To Complete The Star Delta Starting Circuit Of Motor No. 01. Replacement Of Any Faulty Led Indicator With A New Led Indicator Of Equivalent Rating, Colour Coding And Size After Extracting The Old One By Way Of Disconnecting The Existing Wiring Connections And Making Proper Connections To The New Indicator. providing and Fixing Of 1 No. New Reset/Selector Switch In Place Of The Existing Faulty Small Black Reset Switch After Extracting The Old Damaged Switch By Way Of Disconnecting The Existing Wiring Connections, Removing The Old Switch Fitting The New Switch Of Equivalent Type Its Place. Reconnecting The Control Wiring To The New Switch To Restore The Manual Reset Function Of The Motor Protection Relay After A Protection Trip Event. Complete Inspection Of All Internal Control Wiring Of The Panel By Way Of Checking The Insulation Condition Of Flexible Copper Cables, Tightness Of All Crimp/Ferrule Terminations At Terminal Blocks, Contactor Coil Terminals, Push Button Terminals, Indicator Lamp Terminals And Protection Relay Terminals. Replacement Of Any Damaged Or Deteriorated Wiring As Per Actual Site Requirement. Verification Of Correct Phase Sequence Of Incoming Supply Using Phase Sequence Meter Before Energization Of The Panel. Testing And Commissioning Of The Repaired/Upgraded Panel On Full Load By Way Of Energizing The Panel After Completion Of All Repair Works, Verifying Healthiness Of All Three Phase Indicator Lamps At Incoming Section, Checking Voltmeter And Ammeter Readings On All Phases Using Selector Switches, Testing Start/Stop Operation Of Both Motors, Verifying Correct Star To Delta Changeover Of Motor No. 1 Starter, Verifying Display And Protection Functions Of The Motor Protection Devices On All Phases And Recording The Full Load Running Current Of Both Motors. Underground Laying Of Aluminum Cable From From Pump Room To The 100 Kva Distribution Transformer Approximately 20 Feet Apart, By Way Of Excavation Of A Trench Of 9 To 12 Inches Depth And 20 Feet In Length Using Manual Labour With Tools And Tackles. Inspection Of Cable And Insulation Of All Joints And Any Other Locations Found Requiring Insulation During Inspection By Way Of Proper Wrapping With Good Quality Pvc Insulation Tape In Multiple Overlapping Layers So As To Ensure A Moisture Proof And Mechanically Sound Insulation At All Such Points Along The Cable Run. Laying Of The Cable In The Excavated Trench In A Neat And Orderly Manner With Adequate Slack Provided At Both Ends To Facilitate Making Of Electrical Connections. The Cable To Be Laid Without Kinks, Twists Or Sharp Bends So As To Avoid Mechanical Damage To The Cable Insulation. Filling Of The Trench With Excavated Earth With Proper Compaction Using Manual Labour Along With Requisite Tools And Tackles. Removal Of The Old/Damaged Foot Valve Of Priming Pump Of 2 Hp From The Suction Pipe By Way Of Cutting The Rust Nuts And Bolts. providing and Fixing Of 01 No. New 2.5 Inch Foot Valve Of Standard Make With Appropriate Size Of Flange, New Nuts And Bolts Of Appropriate Size Along With Rubber Gaskets/Packing Of Suitable Thickness So As To Ensure A Leak Proof Joint. The Job Also Involves Cutting Of Rusted/Damaged Flange From The Suction Pipe Piece End And Providing And Welding Of New Flange Of Requisite Size To The End Of Suction Pipe Piece. Lowering Of The Suction Pipe Assembly Along With The Newly Fitted Foot Valve Back Into The Canal To Its Original Position Using And Manual Labour. Securing Of The Pipe In Its Correct Position As Per Original Installation. Testing And Commissioning Of The Priming Pump With The New Foot Valve By Way Of Priming The Pump And Running It On Full Load To Verify Proper Suction, Absence Of Air Leakage At The Foot Valve And Correct Pumping Action. Rewinding Of 2 Hp, 3-Phase, 415V, 50 Hz Priming Pump Motor At Lis Khawas Khan By Way Of Dismantling Of Motor Assembly From Pump Set Using Tools And Tackles And Carriage To Workshop. Stripping Of Old Burnt/Damaged Stator Winding From Stator Slots And Cleaning Of Stator Core And Slots. Rewinding Of Stator With New Standard Copper Winding Wire Of Appropriate Gauge In Same Winding Configuration As Original With New Slot Insulation Liner Paper Of Appropriate Class. providing and Fixing Of New Connecting Leads And Terminal Connections Of Appropriate Size. Impregnation Of Completed Winding With Class B/F Insulating Varnish By Way Of Dipping And Oven Baking. Reassembly Of Motor And Replacement Of Bearings If Found Defective. Fabrication And providing and Fixing Of New Terminal Plate In Place Of Existing Worn Out/Damaged Terminal Plate Of Priming Pump Motor By Way Of Removal Of Old Terminal Plate And Fabrication Of New Terminal Plate From Bakelite Sheet Of Appropriate Size And Thickness. providing and Fixing Of New Isi Standard Brass Terminal Studs, Nuts And Washers Of Appropriate Size And Current Rating. Proper Insulation Of Terminal Connections By Way Of Pvc Sleeving And Ferrules Of Appropriate Size. Reconnecting Motor Winding Leads To New Terminals And Testing For Proper Insulation Resistance And Contact Continuity Using Megger. Back Shifting Of Rewound Motor To Site, Fitment And Testing On Full Load. Complete Job Includes Cost Of All Materials, Consumables Including Rebate On Old/Damaged Components, Carriage Of Material To Site, Labour Charges Of Skilled As Well As Semi-Skilled Labour, Testing And Commissioning Charges At Lis Khawas Khan. , Rebate On Old Parts
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
12.
Rural Development #11180993 AOC
Jet Pump Monoblock Pump Bare Pump Underwater Pump Vtpump India Mark - 2 And Mark - 3 Hand Pump Repairing And Spare Parts Rate For Zilha Parishad Bhandara , Jet Pump,Monoblock Pump, Bare Pump Underwater Pum All Submit Rate As Pergsda-Item Sheet , India Mark -2 & 3 Hand Pump Repairing Drive Out Thepipe Line With Diameter Of 65.0 M.M. , Drive Outthepipe Line With Diameter Of 65.0 M.M Which Fell In Well. , Drive Out Thepipe Line With Diameter Of 32.0 M.M From Whichfell In Well. , Drive Out Thepipe Line With Diameter Of 32.0 M.M From Well. , Repairing Of Jet Motor Pump & Pipelinedrive Out Inner Pipeline With Jet Assembly Of Jetpump From 1.0 Hp To 5.0 Hp Well. , To Fit The Inner And Outer Pipeline Of The Jet Pump In 1.0 Hp To5.0 Hp Well. , To Insert Inner Pipeline Of Jetpump In Well. (After Repairing.) , To Insert Inner & Outer Pipeline Of Jetpump In Well. (After Repairing.) , To Pull Out The Stucked, Fell Or Caught In Dreg Pump Set.( Contracter Use Their Own Tools.) , To Increse Or Reduse The Pipe Line Of Jet Pump Inh Well. ( For Every 3.0 M. ) , To Submit In The Officejet Pump, Motor Pipeline, Starter Panel Board Tin & Other Assesaries Of Laghu Panee Purwatha Yojna In Well. , New Pump Set (Upto 1.0 To 5.0 Hp) To Fit In Well, To Give Panel Wiring Arthig Test Report & Start After Electric Supply. (Z.P. Providespumpset Panel, Arthing Material G.I. Wire, Plate, Pipe Andother Assesaries.) , To Drive Out Motor And Pump From Jet Pump , To Fit1.0 Hp To 5.0 Hp Jet Motor Pump. , To Rewinding Electric Motor With Copper Wire , Above Rate Valid Forwithout Returning Old Copper Wire, 1.0 Hp To 5.0 Hp Open Pump Motor Rewinding. , To Open The Jet Motor, Over Oiling, Fitting And Testing , Roter Pump Shaft Turning And Polishing. , To Make Upper And Lower Bush Of Baring Cover Sit And Housing Of Jet Pump. , To Test Electric Pump On Site ( Transport And With Minor Repairing) , To Repaire Panel Board & Starter Of All Types Motor & Any Hp Control Panel Starter Minor Repairing To Fit Grif Set, Rottery Swich, Contracter Plate, Ampear Meter, Volt Meter, On-Off Switch, Fuse And Minor Wiring. , Starter Panel Board Main Repairing & To Fit Coilrelay, Single Phasing Preventer Water Label Guard & Totle Wiring Of 1.0 Hp To 10.0 Hp Pump. , Starter Panel Board Main Repairing & To Fit Coilrelay, Single Phasing , Preventer Water Label Guard & Totle Wiring Of 10.0 Hp To 30 Hp Pump. , Preventer Water Label Guard & Totle Wiring Of 31.0 Hp To 40 Hp Pump. , To Remove Tin Shed Flashing Of Pump If Necessary And Fit As It Is After Work. , To Remove Handpump With Pipeline For Flashing And Insert 10 Feet G.I.Pipeline Towards 32 M.M. Dimeter& Remove After Flashing And Fithandpump As It Is Before. , To Remove Handpump For Capacity Test And After Testing Fit As It Is Before. , Single Phase 1 Hp To 2 Hp Electric Pump Capacity Test For Regular Three Hour With Help Of Generator , Yieldtest 1 Hp To 2 Hp Electric Pump Capacity Test For Regular Three Hour With Help Of Generatorwith Necc Equip , Yieldtest 2 Hp To5 Hp Electric Pump Capacity Test For Regular Three Hour With Help Of Generatorwith Necc Equip , Yield Test 2 Hp To5 Hp Electric Pump Capacity Test For Regular Three Hour Withouthelpof Generatorwith Necc Equip , Spare Parts Of Jet Pump Baring Upper , Baring Lower , Empelor Key , Pump Bush , Air Fan ( With Pvc Pin) , Stand Nut Kit , Nut Bolt Kit , Air Cock , Pressure Regulating Volve , Pressure Regulating Difrom , Baring Plate Top / Bottom , Jet Assembly Packer Type Full , Packer Foot Volve , Packer Rubber Seal Set , Packer Backet Set , Gland Rope , Rubber Packing Set , Gland Rope Plate , Empelor , D) Other Material G. I. Coplling Heavy Duty , I) 32 M.M. , Ii) 40 M.M. , Iii) 50 M.M. , Iv) 65 M.M. , V) 75 M.M. , Vi) 100 M.M. , Vii) 125 M.M. , Viii) 150 M.M. , Bend Heavy Duty , I) 32 M.M. , Ii) 40 M.M. , Iii) 50 M.M. , Iv) 65 M.M. , V) 75 M.M. , Vi) 100 M.M. , Vii) 125 M.M. , Viii) 150 M.M. , 3) Foot Volve:I) 32 M.M. , Ii) 40 M.M. , Iii) 50 M.M. , Iv) 65 M.M. , V) 75 M.M. , Vi) 100 M.M. , Vii) 125 M.M. , Viii) 150 M.M. , Wooden Board 3 X 2 F X ½ “ , Iron Box 18 Guage Tin 3F X 2F X 1F , G.I.Pipe 1½“ / 1¼ “ Cutting Threding , G.I.Pipe 2“ Cutting Threding , G.I.Pipe 2½“ / 3 “ Cutting Threding , E)Submercible Pump Repairing: 1.0 Hp To 3.5 Hp , 4.0 Hp To 5.0 Hp , 6.0 Hp To 10.0 Hp , 11.0 Hp To 15.0 Hp , 16.0 Hp To 20.0 Hp , 21.0 Hp To 30.0 Hp , 31.0 Hp To 50.0 Hp , F) To Remove Motor Pump Set With Pipelinefrom Well: 1 Hp To 6.0 Hp , 7.0 Hp To 15 Hp , 16.0 Hp To 30.0 Hp , 31.0 Hp To 50.0 Hp , G) To Pull Out The Stuck, Fell Or Caught In Dreg Pump Set With Pipelinefrom Well: 1 Hp To 6.0 Hp , 2) 7.0 Hp To 15 Hp , 3)16.0 Hp To 30.0 Hp , 4)31.0 Hp To 50.0 Hp , H) To Fit Motor Pump In Well With Pipe Line: 1)1 Hp To 6.0 Hp , 2)7.0 Hp To 15 Hp , 3) 16.0 Hp To 30.0 Hp , 4) 31.0 Hp To 50.0 Hp , I) To Increase Or Reduse Pipeline Of Submercible Pump In Well Rate 3 Meter / Per Pipe: 1 Hp To 6.0 Hp , 7.0 Hp To 15 Hp , 16.0 Hp To 30.0 Hp , 31.0 Hp To 50.0 Hp , J) To Submit In The Officejet Pump, : 1 Hp To 7.5 Hp , 8.5 Hp To 15 Hp , 16.0 Hp To 30.0 Hp , 31.0 Hp To 50.0 Hp , K) New Pump Set (Upto 1.0 To 5.0 Hp) :1 Hp To 7.5 Hp , 8.5 Hp To 15 Hp , 16.0 Hp To 30.0 Hp , 31.0 Hp To 50.0 Hp , L) To Open Sub Motor, Repairing, Fitting And Testing.: 1 Hp To 7.5 Hp , 8.5 Hp To 15 Hp , 16.0 Hp To 30.0 Hp , 31.0 Hp To 50.0 Hp , M) To Open Sub Pump, Repairing, Fitting And Testing.:1)1 Hp To 7.5 Hp , 2) 8.5 Hp To 15 Hp , 3)16.0 Hp To 30.0 Hp , 4)31.0 Hp To 50.0 Hp , N) To Repaire Sub Motor And Sub Pump:To Sub Motor / Pump Bush Fitting Per , Damage Stater Repairing , Roter Shaft Turning And Polishing , Damage Roter Repairing (Rewinding) , Sub Pump Shaft Turning & Polishing , To Joint Cable With Kit , O) Sub Motor & Sub Pump Spare Parts1 To 5 Hp: I) Sub Motor Bush , Ii) Sub Pump Bush , Thirst Baring Block , Thirst Baring Full , Block , Ring , Upper Stage Casing , Lower Stage Casing , Middle Stage Casing , I) Empelor , Ii) Brass Empelor , Nekring , Defuser , Pump Key , Rubber Parts Kit , Submotor Base , Stenner , Male- Female Bush , Male- Famale Key , Nrv Stage Casing , Stud Big , Stud Small , Motor Bush Housing , I) Upper , Ii) Lower , Alen Srew , Ss Slivemotor /Pump , Ss Slive Cover , O) Sub Motor & Sub Pump Spare Parts1 To 7.5 Hp: I) Sub Motor Bush , Ii) Sub Pump Bush , Thirst Baring Block , Thirst Baring Full , Block , Ring , Upper Stage Casing , Lower Stage Casing , Middle Stage Casing , I) Empelor , Ii) Brass Empelor , Nekring , Defuser , Pump Key , Rubber Parts Kit , Submotor Base , Stenner , Male- Female Bush , Male- Famale Key , Nrv Stage Casing , Stud Big , Stud Small , Motor Bush Housing , I) Upper , Ii) Lower , Alen Srew , Ss Slivemotor /Pump , Ss Slive Cover , O) Sub Motor & Sub Pump Spare Parts 8 To15 Hp :I) Sub Motor Bush , Ii) Sub Pump Bush , Thirst Baring Block , Thirst Baring Full , Block , Ring , Upper Stage Casing , Lower Stage Casing , Middle Stage Casing , I) Empelor , Ii) Brass Empelor , Nekring , Defuser , Pump Key , Rubber Parts Kit , Submotor Base , Stenner , Male- Female Bush , Male- Famale Key , Nrv Stage Casing , Stud Big , Stud Small , Motor Bush Housing , I) Upper , Ii) Lower , Alen Srew , Ss Slivemotor /Pump , Ss Slive Cover , O) Sub Motor & Sub Pump Spare Parts16 To30 Hp: I) Sub Motor Bush , Ii) Sub Pump Bush , Thirst Baring Block , Thirst Baring Full , Block , Ring , Upper Stage Casing , Lower Stage Casing , Middle Stage Casing , I) Empelor , Ii) Brass Empelor , Nekring , Defuser , Pump Key , Rubber Parts Kit , Submotor Base , Stenner , Male- Female Bush , Male- Famale Key , Nrv Stage Casing , Stud Big , Stud Small , Motor Bush Housing , I) Upper , Ii) Lower , Alen Srew , Ss Slivemotor /Pump , Ss Slive Cover , 1)Three Ply Coreflat Flexible Submercible Cable: I) 1.5 Sq.M.M. , Ii) 2.5 Sq.M.M. , Iii) 4 Sq.M.M. , Iv) 6 Sq.M.M. , V) 10 Sq.M.M. , Vi) 1.5 Sq.M.M. , 1)Three Ply Coreflat : Arm Cable:I) 1.00 Sq.M.M. , Ii) 1.50 Sq.M.M. , Iii) 2.50 Sq.M.M. , Iv) 4.00 Sq.M.M. , V) 6.00 Sq.M.M. , Vi) 10.00 Sq.M.M. , Vii) 16.00 Sq.M.M. , Viii) 25.00 Sq.M.M. , Ix) 35.00 Sq.M.M. , X) 50.00 Sq.M.M. , Copper Wire P.V.C. Insulated & P.V.C. Coated: I) 3/20 , Copper Wire P.V.C. Insulated & P.V.C. Coated: Ii) 7/20 , Copper Wire P.V.C. Insulated & P.V.C. Coated: Iii) 7/16 , 27)New Pump Shaft I) 1.5 Hp To 6 Hp , 27)New Pump Shaft Ii) 7.5 Hp To 15 Hp , 27)New Pump Shaft Iii) 16 Hp To 30 Hp , Borewell Protecting Plate , Borewell Protecting Cover , P)25.0 Hp To 40 Hp V.T. Motor Pump Set Repairing 25Hp: Drive Out V.T. Motor From Well , V.T. Pump Fit In Well , Drive Out Colume Assembly With Pipeline From Well , To Fit Colume Assembly With Pipeline In Well , To Open V.T. Motor , V.T. Motor Fitting & Testing , Bowl Assembly Fitting & Testing , To Open Bowl Assembly , V.T. Pump Rewinding With Copper Wire. Withoutreturning Old Copper Wire , Allignment Checking & Repairing , I) Line Shaft , Ii) Colume Pipe , Iii) Oil Tube , Cutting & Threading , I) Line Shaft (R.H./L.H) , Ii) Colume Pipe (R.H./L.H) , Iii) Oil Tube (R.H./L.H) , To Fit New Flage, Threading Coller, Welding,Nutboltin Colume Pipe , To Making ,Bearing Sheet On Lathe Machine , Bearing Plate Both Side , P)25.0 Hp To 40 Hp V.T. Motor Pump Set Repairing 35Hp: Drive Out V.T. Motor From Well , V.T. Pump Fit In Well , Drive Out Colume Assembly With Pipeline From Well , To Fit Colume Assembly With Pipeline In Well , To Open V.T. Motor , V.T. Motor Fitting & Testing , Bowl Assembly Fitting & Testing , To Open Bowl Assembly , V.T. Pump Rewinding With Copper Wire. Withoutreturning Old Copper Wire , Allignment Checking & Repairing , I) Line Shaft , Ii) Colume Pipe , Iii) Oil Tube , Cutting & Threading , I) Line Shaft (R.H./L.H) , Ii) Colume Pipe (R.H./L.H) , Iii) Oil Tube (R.H./L.H) , To Fit New Flage, Threading Coller, Welding,Nutboltin Colume Pipe , To Making ,Bearing Sheet On Lathe Machine , Bearing Plate Both Side , P)25.0 Hp To 40 Hp V.T. Motor Pump Set Repairing 40Hp : Drive Out V.T. Motor From Well , V.T. Pump Fit In Well , Drive Out Colume Assembly With Pipeline From Well , To Fit Colume Assembly With Pipeline In Well , To Open V.T. Motor , V.T. Motor Fitting & Testing , Bowl Assembly Fitting & Testing , To Open Bowl Assembly , V.T. Pump Rewinding With Copper Wire. Withoutreturning Old Copper Wire , Allignment Checking & Repairing , I) Line Shaft , Ii) Colume Pipe , Iii) Oil Tube , Cutting & Threading , I) Line Shaft (R.H./L.H) , Ii) Colume Pipe (R.H./L.H) , Iii) Oil Tube (R.H./L.H) , To Fit New Flage, Threading Coller, Welding,Nutboltin Colume Pipe , To Making ,Bearing Sheet On Lathe Machine , Bearing Plate Both Side , Q)25 Hp To 40 Hp V.T. Pum Spare Part 25Hp : 1) V.T. Motor Baring , I) Upper , Ii) Lower , Discharge & Sectioncase Baring Bush Gun Metal , Water Seal (Oil Water Separater) , Line Shaft , Oil Tube , T.T. Plate Cast Iron , Brain Rubber Bush (Spider) , Net (Cast Iron) , Nut Bolt ¾“ X 2 “ , Nut Bolt ¾“ X 6 “ , Rubber Shit , T.T. Plate Bush , Neck Ring (Gun Metal) , Impelor(Gun Metal) , Browl Assembly Casing , 6” Colume Pipe M.S. , 8” Colume Pipe M.S. , Transformer Oil , Pump Colet , Shaft Tube Oil 10 No. , Impelor Pump Shaft , Litern Ring , Gide Spider , Colume Pipe Coplling , Line Shaft Coplling , Oil Tube Baring , Glad Nut , Top Oil Tube , Spider Baring Bush , Guide Spider Rubber Bush With Sirclip , Rubber Bush/ Baring , Line Shaft Slive S.S. , Water Lubricating Tube , Stuffing Box Bush & With Gaskit , Stuffing Box Baring , Latern Ring , Sole Plate , Base Plate , Water Deflector , Q)25 Hp To 40 Hp V.T. Pum Spare Part 25Hp : 1) V.T. Motor Baring , I) Upper , Ii) Lower , Discharge & Sectioncase Baring Bush Gun Metal , Water Seal (Oil Water Separater) , Line Shaft , Oil Tube , T.T. Plate Cast Iron , Brain Rubber Bush (Spider) , Net (Cast Iron) , Nut Bolt ¾“ X 2 “ , Nut Bolt ¾“ X 6 “ , Rubber Shit , T.T. Plate Bush , Neck Ring (Gun Metal) , Impelor(Gun Metal) , Browl Assembly Casing , 6” Colume Pipe M.S. , 8” Colume Pipe M.S. , Transformer Oil , Pump Colet , Shaft Tube Oil 10 No. , Impelor Pump Shaft , Litern Ring , Gide Spider , Colume Pipe Coplling , Line Shaft Coplling , Oil Tube Baring , Glad Nut , Top Oil Tube , Spider Baring Bush , Guide Spider Rubber Bush With Sirclip , Rubber Bush/ Baring , Line Shaft Slive S.S. , Water Lubricating Tube , Stuffing Box Bush & With Gaskit , Stuffing Box Baring , Latern Ring , Sole Plate , Base Plate , Water Deflector , Q)25 Hp To 40 Hp V.T. Pum Spare Part 40Hp: 1) V.T. Motor Baring , I) Upper , Ii) Lower , Discharge & Sectioncase Baring Bush Gun Metal , Water Seal (Oil Water Separater) , Line Shaft , Oil Tube , T.T. Plate Cast Iron , Brain Rubber Bush (Spider) , Net (Cast Iron) , Nut Bolt ¾“ X 2 “ , Nut Bolt ¾“ X 6 “ , Rubber Shit , T.T. Plate Bush , Neck Ring (Gun Metal) , Impelor(Gun Metal) , Browl Assembly Casing , 6” Colume Pipe M.S. , 8” Colume Pipe M.S. , Transformer Oil , Pump Colet , Shaft Tube Oil 10 No. , Impelor Pump Shaft , Litern Ring , Gide Spider , Colume Pipe Coplling , Line Shaft Coplling , Oil Tube Baring , Glad Nut , Top Oil Tube , Spider Baring Bush , Guide Spider Rubber Bush With Sirclip , Rubber Bush/ Baring , Line Shaft Slive S.S. , Water Lubricating Tube , Stuffing Box Bush & With Gaskit , Stuffing Box Baring , Latern Ring , Sole Plate , Base Plate , Water Deflector , I) Drive Out 1 Hp To 3 Hp Monoblock Pump , Ii) Drive Out 4 Hp To 10 Hp Monoblock Pump , Ii) 2 To 3Hp Monoblock Motor Rewinding , Iii) 4 To 5Hp Monoblock Motor Rewinding , Iv) 6 To 7½Hp Monoblock Motor Rewinding , V) 8 To 10Hp Monoblock Motor Rewinding , Monoblock Pump Open, Repairing, Fitting & Testing I) 1 To 1½Hp , Monoblock Pump Open, Repairing, Fitting & Testing Ii) 2 To 5Hp , Monoblock Pump Open, Repairing, Fitting & Testingiii) 6 To 10Hp , Roter Pump Shaft Turning & Polishingi) 1 To 5 Hp , Roter Pump Shaft Turning & Polishingii) 6 To 10Hp , To Make Monoblock Pump Bush & Housing (Baring)I) 1 To 1½Hp , To Make Monoblock Pump Bush & Housing (Baring)Ii) 2 To 5Hp , To Make Monoblock Pump Bush & Housing (Baring)Iii) 6 To 10Hp , Tofit New Pump Set I) 1 To 1½Hp , Tofit New Pump Setii) 2 To 5Hp , Tofit New Pump Set Iii) 6 To 10Hp , T) Monoblock Pump Spare Partsbaring1 To 1½ Hp(Driving Side) , Baring (Driven Side) , Impelor Key , Pump Bush , Air Fan , Sturnut Key , Baring Plate Both Side1 Item , Water Seal , Gland Rope , Gland Bush , Gland Plate , Roter Fitted Shaft , Latern Ring , Impelor Brass , Impelor C.I. , Defuser , Baring Housing , Neck Ring , Foot Volve , Fluge (Dilevery/ Suction) , Shaft Sleve , Delivery Casing , Stater Fitted Motorbody , Spacer , Fan Cover , Water Deflector , T) Monoblock Pump Spare Parts 2 To 3 Hp Baring (Driving Side) , Baring (Driven Side) , Impelor Key , Pump Bush , Air Fan , Sturnut Key , Baring Plate Both Side1 Item , Water Seal , Gland Rope , Gland Bush , Gland Plate , Roter Fitted Shaft , Latern Ring , Impelor Brass , Impelor C.I. , Defuser , Baring Housing , Neck Ring , Foot Volve , Fluge (Dilevery/ Suction) , Shaft Sleve , Delivery Casing , Stater Fitted Motorbody , Spacer , Fan Cover , Water Deflector , T) Monoblock Pump Spare Parts 4 To 5 Hp Baring (Driving Side) , Baring (Driven Side) , Impelor Key , Pump Bush , Air Fan , Sturnut Key , Baring Plate Both Side1 Item , Water Seal , Gland Rope , Gland Bush , Gland Plate , Roter Fitted Shaft , Latern Ring , Impelor Brass , Impelor C.I. , Defuser , Baring Housing , Neck Ring , Foot Volve , Fluge (Dilevery/ Suction) , Shaft Sleve , Delivery Casing , Stater Fitted Motorbody , Spacer , Fan Cover , Water Deflector , T) Monoblock Pump Spare Partsbaring 6 To 7½Hp (Driving Side) , Baring (Driven Side) , Impelor Key , Pump Bush , Air Fan , Sturnut Key , Baring Plate Both Side1 Item , Water Seal , Gland Rope , Gland Bush , Gland Plate , Roter Fitted Shaft , Latern Ring , Impelor Brass , Impelor C.I. , Defuser , Baring Housing , Neck Ring , Foot Volve , Fluge (Dilevery/ Suction) , Shaft Sleve , Delivery Casing , Stater Fitted Motorbody , Spacer , Fan Cover , Water Deflector , T) Monoblock Pump Spare Partsbaring 8 To 10Hp(Driving Side) , Baring (Driven Side) , Impelor Key , Pump Bush , Air Fan , Sturnut Key , Baring Plate Both Side1 Item , Water Seal , Gland Rope , Gland Bush , Gland Plate , Roter Fitted Shaft , Latern Ring , Impelor Brass , Impelor C.I. , Defuser , Baring Housing , Neck Ring , Foot Volve , Fluge (Dilevery/ Suction) , Shaft Sleve , Delivery Casing , Stater Fitted Motorbody , Spacer , Fan Cover , Water Deflector , U) Bare Pump Repairingto Drive Out Bare Pump I) 10 To 20 Hp , Ii) 21 To 50 Hp , Bare Pump To Open, Repairing, Fitting & Testing I) 10 To 20 Hp , Ii) 21 To 50 Hp , Pump Shaft Turning & Polishing I) 10 To 20 Hp , Ii) 21 To 50 Hp , To Make Pump Bush & Housing (Baring) I) 10 To 20 Hp , Ii) 21 To 50 Hp , To Fit New Bare Pump I) 10 To 20 Hp , Ii) 21 To 50 Hp , Pump Repairing & Fittingi) 10 To 20 Hp , Ii) 21 To 50 Hp , To Make Gland Bush Housing I) 10 To 20 Hp , Ii) 21 To 50 Hp , Drive Out Bare Pump Pipe Line With Foot Volve I) 10 To 20 Hp , Ii) 21 To 50 Hp , To Fit Bare Pump Pipeline With Foot Volve I) 10 To 20 Hp , Ii) 21 To 50 Hp , V) Bare Pump Spare Parts 10 To 15 Hp Baring (Ball Baring) , Rolar Baring , Impelor Key , Pump Bush , Stud Nut , Nut Bolt Kit , Air Cock , Base Plate , Water Seal , Gland Bush , Gland Plate , Pump Shaft , Latern Ring , Impelor Brass , Impelor (C.I) , Difuser , Baring Housing , Neck Ring (Small) , Neck Ring (Big) , Flasher , Foot Volve , Check Nut , Impelor Housing , Roter Casing , Roter , Delevery Casing , Stuffing Box Bush , Shaft Sleve , Water Deflector , Cuplling Half Flexible , Baring Cover , Grees Cup , Flage Section/ Delivery , V) Bare Pump Spare Parts 16 To 20Hp Baring (Ball Baring) , Rolar Baring , Impelor Key , Pump Bush , Stud Nut , Nut Bolt Kit , Air Cock , Base Plate , Water Seal , Gland Bush , Gland Plate , Pump Shaft , Latern Ring , Impelor Brass , Impelor (C.I) , Difuser , Baring Housing , Neck Ring (Small) , Neck Ring (Big) , Flasher , Foot Volve , Check Nut , Impelor Housing , Roter Casing , Roter , Delevery Casing , Stuffing Box Bush , Shaft Sleve , Water Deflector , Cuplling Half Flexible , Baring Cover , Grees Cup , Flage Section/ Delivery , V) Bare Pump Spare Parts 21 To 50 Hp Baring (Ball Baring) , Rolar Baring , Impelor Key , Pump Bush , Stud Nut , Nut Bolt Kit , Air Cock , Base Plate , Water Seal , Gland Bush , Gland Plate , Pump Shaft , Latern Ring , Impelor Brass , Impelor (C.I) , Difuser , Baring Housing , Neck Ring (Small) , Neck Ring (Big) , Flasher , Foot Volve , Check Nut , Impelor Housing , Roter Casing , Roter , Delevery Casing , Stuffing Box Bush , Shaft Sleve , Water Deflector , Cuplling Half Flexible , Baring Cover , Grees Cup , Flage Section/ Delivery , W) Bare Motor Repairingdrive Out Bare Motor , W) Bare Motor Repairingdrive Out Bare Motor I) 10 To 20 Hp , W) Bare Motor Repairingdrive Out Bare Motor Ii) 21 To 50 Hp , Bare Motor Rewinding I) 1 To 5 Hp , Bare Motor Rewinding Ii) 6 To 10 Hp , Bare Motor Rewinding Iii) 11 To 15 Hp , Bare Motor Rewinding Iv)16 To 20 Hp , Bare Motor Rewindingv) 21 To 30 Hp , Bare Motor Rewinding Vi) 31 To 35 Hp , Bare Motor Rewinding Vii) 36 To 40 Hp , Bare Motor Rewinding Viii) 41 To 50 Hp. , Motor Opening, Over Oiling, Fitting & Testingi) 1 To 5 Hp , Motor Opening, Over Oiling, Fitting & Testingii) 6 To 10 Hp , Motor Opening, Over Oiling, Fitting & Testing Iii) 11 To 15 Hp , Motor Opening, Over Oiling, Fitting & Testingiv)16 To 20 Hp , Motor Opening, Over Oiling, Fitting & Testing V) 21 To 30 Hp , Motor Opening, Over Oiling, Fitting & Testing Vi) 31 To 35 Hp , Motor Opening, Over Oiling, Fitting & Testingvii) 36 To 40 Hp , Motor Opening, Over Oiling, Fitting & Testing Viii) 41 To 50 Hp. , Roter Shaft Turning & Polishing I) 1 To 5 Hp , Roter Shaft Turning & Polishing Ii) 6 To 10 Hp , Roter Shaft Turning & Polishing Iii) 11 To 15 Hp , Roter Shaft Turning & Polishingiv)16 To 20 Hp , Roter Shaft Turning & Polishing V) 21 To 30 Hp , Roter Shaft Turning & Polishing Vi) 31 To 35 Hp , Roter Shaft Turning & Polishingvii) 36 To 40 Hp , Roter Shaft Turning & Polishing Viii) 41 To 50 Hp. , To Make Motor Bush & Housing (Baring Sheet) I) 1 To 5 Hp , To Make Motor Bush & Housing (Baring Sheet)Ii) 6 To 10 Hp , To Make Motor Bush & Housing (Baring Sheet)Iii) 11 To 15 Hp , To Make Motor Bush & Housing (Baring Sheet)Iv)16 To 20 Hp , To Make Motor Bush & Housing (Baring Sheet)V) 21 To 30 Hp , To Make Motor Bush & Housing (Baring Sheet)Vi) 31 To 35 Hp , To Make Motor Bush & Housing (Baring Sheet) Vii) 36 To 40 Hp , To Make Motor Bush & Housing (Baring Sheet) Viii) 41 To 50 Hp. , To Fit New Motor I) 1 To 5 Hp , To Fit New Motor Ii) 6 To 10 Hp , To Fit New Motoriii) 11 To 15 Hp , To Fit New Motoriv)16 To 20 Hp , To Fit New Motorv) 21 To 30 Hp , To Fit New Motorvi) 31 To 35 Hp , To Fit New Motorvii) 36 To 40 Hp , To Fit New Motor Viii) 41 To 50 Hp. , Panel Board & Starter Repairingi) 1 To 5 Hp , Panel Board & Starter Repairingii) 6 To 10 Hp , Panel Board & Starter Repairingiii) 11 To 15 Hp , Panel Board & Starter Repairingiv)16 To 20 Hp , Panel Board & Starter Repairing V) 21 To 30 Hp , Panel Board & Starter Repairing Vi) 31 To 35 Hp , Panel Board & Starter Repairing Vii) 36 To 40 Hp , Panel Board & Starter Repairing Viii) 41 To 50 Hp. , To Fit Motor As It Isi) 1 To 5 Hp , To Fit Motor As It Isii) 6 To 10 Hp , To Fit Motor As It Is Iii) 11 To 15 Hp , To Fit Motor As It Isiv)16 To 20 Hp , To Fit Motor As It Isv) 21 To 30 Hp , To Fit Motor As It Is Vi) 31 To 35 Hp , To Fit Motor As It Isvii) 36 To 40 Hp , To Fit Motor As It Isviii) 41 To 50 Hp. , X)Bare Motor Spare Parts 10 To 15:Bearing , Air Fan , Shaft , Bearing Plate , Motor Bush , Roter Assembly , Stud Nut Kit , Nut Bolt Kit , X)Bare Motor Spare Parts 6 To 20:Bearing , Air Fan , Shaft , Bearing Plate , Motor Bush , Roter Assembly , Stud Nut Kit , Nut Bolt Kit , X)Bare Motor Spare Parts 21 To 50 :Bearing , Air Fan , Shaft , Bearing Plate , Motor Bush , Roter Assembly , Stud Nut Kit , Nut Bolt Kit , Y)Vaccume Pump Repairing Drive Out Pumpi) 1 To 3 Hp , Y)Vaccume Pump Repairing Drive Out Pump Ii) 4 To 5 Hp , Motor Rewinding I) 1 To 3 Hp , Motor Rewinding Ii) 4 To 5 Hp , Pump Opening, Repairing, Over Oiling, Fitting & Testingi) 1 To 3 Hp , Pump Opening, Repairing, Over Oiling, Fitting & Testingii) 4 To 5 Hp , Roter Shaft Turning & Polishing I) 1 To 3 Hp , Roter Shaft Turning & Polishing Ii) 4 To 5 Hp , To Make Vaccume Pump Bush & Baring Housing I) 1 To 3 Hp , To Make Vaccume Pump Bush & Baring Housing Ii) 4 To 5 Hp , To Fit New Pump Set I) 1 To 3 Hp , To Fit New Pump Set Ii) 4 To 5 Hp , Panel Board & Starter Repairing I) 1 To 3 Hp , Panel Board & Starter Repairing Ii) 4 To 5 Hp , Z) Vaccume Pump Spare Parts 1 To 3 Hp :Baring , Impelor Key , Pump Bush , Air Fan , Sturnut Key , Baring Plate Both Side , Mechanical Seal , Gland Rope , Gland Bush , Gland Plate , Roter Fitted Shaft , Latern Ring , Roter G.M. , Fan Cover , Spacer , Baring Housing , Neck Ring , Port Plate , Flage (Delevery/ Section) , Shaft Sleve , Saction & Delivery Chember , Steter Fitted Motorbody , Tie Rod , Roter Casing , Liquid Diflector , Z) Vaccume Pump Spare Parts4 To 5 Hp :Baring , Impelor Key , Pump Bush , Air Fan , Sturnut Key , Baring Plate Both Side , Mechanical Seal , Gland Rope , Gland Bush , Gland Plate , Roter Fitted Shaft , Latern Ring , Roter G.M. , Fan Cover , Spacer , Baring Housing , Neck Ring , Port Plate , Flage (Delevery/ Section) , Shaft Sleve , Saction & Delivery Chember , Steter Fitted Motorbody , Tie Rod , Roter Casing , Liquid Diflector , Starter Reley I) 6 To 10A. , Ii) 9 To 14 A. , Iii) 13 To 21 A , Iv) 19 To 27 A , V) 21 To 32 A , Starter No Volt & Over Load Coil , Contactor Set Fulli) S. K. -1 , Ii)M.L. -1 , Iii) M.L. -2 , Iv) M.L. -3 , V) M.L. - 4 , Vi) M.L. - 5 , Vii) M.L. - 6 , Viii) M.L. - 7 , Ix) M.L. - 8 , X) M.L. - 9 , Xi) M.L. - 10 , Reley Plate (Kit) , Contactor Point Kiti) S. K. -1 , Ii) M.L. -1 , Iii) M.L. -2 , Iv) M.L. -3 , V) M.L. - 4 , Vi) M.L. - 5 , Vii) M.L. - 6 , Viii) M.L. - 7 , Ix) M.L. - 8 , X) M.L. - 9 , Xi) M.L. - 10 , I) Fuse Grip 16 A. , Ii) Fuse Grip 32 A. , Iii) Fuse Grip 63 A. , Iv) Fuse Grip 100 A , V) Fuse Grip 200 A.. , Fuse Basei) 16 A. , Ii) 32 A. , Iii) 63 A. , Iv) 100 A. , V) 200 A. , Connector Plate , I) Volt Meter 0-440 Volt Small , Ii) Volt Meter 0-440 Volt Big , Ampear Meter , Ampear Meteri) 0 To 15 A. , Ii) 0 To 50 A. , Iii) 0 To 100 A. , Iv) 0 150 A. , Capasitor 1 K.V.A.R. , Single Phasing Preventor , Water Level Guardwith 60 M. Wire , On-Off Rotery Switch , Volt Meter / Ampere Meter Switch , Nuon Indicator Lamp , Main Switch 440 Volt Three Phase , I) 16 A. , Ii) 32 A. , Iv) 100 A. , V) 200 A. , M.S.E.B. Unit I) 32 A. , Ii) 63 A. , Iii) 100 A. , Iv) 200 A. , H.R. C. Fuse I) 100 A. , Ii) 125 A. , Iii) 200 A. , Aquazilary Coil , Timer Coil , C.T. Coil I) 60 A. , Ii) 100 A. , Iii) 200 A. , Tog Tester , Multi Meter , Insulation Tester , Meger , Hand Gloves - 1 Pair (Rubber) , Insulated Rubber Matting , To Arthing With Arthing 300 X 300 X 50 M.M. Arthing Plate,G I. Pipe & Arthing Wire , To Arthing With Arthing 450 X 450 X 50 M.M. Arthing Plate, G I. Pipe & Arthing Wire , Arthing Wire 14 To 6 Guage , Starter D.O.L , I) 1 To 5 Hp , Ii) 5 To 10 Hp , Iii) Star Delta Auto 10 To 20 Hp , Vi) Star Delta Auto 21 To 30 Hp , V) Auto Transfarmer Starter 20 To 30 Hp , Vi) Auto Transfarmer Starter 31 To 50 Hp , Transfarmer Coil Rewinding With Copper Wire In Transfarmer Starter. Without Returning Old Copper Wire. , Change Over Switch 50 A. 3 Phase , Change Over Switch 100 A. 3 Phase , Change Over Switch 200 A. 3 Phase , Buz Bar 30 To 50 Hp , Transfarmer Oil , Discharge With Stainless Steel Pump Shaft And Motor Suitable For Working On 415 V± 10%, 3Ph, 50 Hz., A.C. Supply, Cable Guard, Thrust Carbon/Fibre Bearing To Accept Entire Hydraulic Thrust, Water Proofwinding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Suction Stainer Shall Also Be Provided. 3 Core, Single/Double Run Copper Conductor Submersible Type Flat Cable 3 Mtr. And 3 Pairs Of Erection Clamps. Rates Per Pump Upto 20 Stages (As Per Design)Submercsible Pump Set 100Mm Dia(With Polypropelene/ Noryl Impeller)Up To 20 Stages1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze /Stainless(Cf8m) Impeller) Up To 8 Stages 1.5 Hp , 2.0Hp , 3.0Hp , 4.0Hp , 5.0 Hp , 6.0Hp , 7.5 Hp , Submersible Pump 150 Mm Dia (With Bronze /Stainless(Cf8m) Impeller) Up To 12 Stages1hp , 12.5Hp , 15Hp , Submersible Pump 150 Mm Dia (With Bronze /Stainless(Cf8m) Impeller) Up To 15 Stages17.5 Hp , 20 Hp , 22.5 Hp , Submersible Monoblock (With Bronze / Stainless Steel (Cf8m) Impeller ) Horizontal/Vertical -Upto 3 Stages( Motor With Water Lubricated Bearing To Accept Entire Hydraulice Threst ) 3 Hp , 5Hp , 7.5 Hp , 10 Hp , Supplying And Erecting Submersible Pumpset 0.75Kw/ 1Hp With 415V 50 Cycles Ac Supply Suitable For 100Mm Dia Borewell . Suitable For 10 To 50 Lpm Discharge At 70 To 20 M And ( Max Effciency At 52 M. Head 30 Lpm Discharge) & Delivery Pipe Of 32 Mmdiameter With A Neccssary H. Type Clamp As Per Specification No. Wp. Smp , Suppluing And Erecting 3 Core Pvc. Insulated Flat Flexible Submersible Cable With Copper Conductor, Pvc Insulated And Pvc Sheathed 3Core 2.5 Sq.Mm , 3Core 4 Sq.Mm , 3Core 6 Sq.Mm , 3Core 10 Sq.Mm , Providing, Suplying & In Standard Lenghts Mdpe Pipes. Conforming To I.S.O. 4427:1996/With Necessary Jointing Material Like Mechanical Connection I.E. Thread/Insert Joint/Quick Release Coupler Joint/Compresion Fitting Joint Or Flanged Joint. ...............Etc Complete. Pn-16Sdr - 9 20 Mm , 25Mm , 32Mm , 40Mm , 50Mm , 63Mm , 75Mm , 90Mm , Providing, Suplying & In Standard Lenghts Hdpe Pipes. Conforming To I.S.O. 4427:1996/With Necessary Jointing Material Like Mechanical Connection I.E. Thread/Insert Joint/Quick Release Coupler Joint/Compresion Fitting Joint Or Flanged Joint. ...............Etc Complete.6Kg 32Mm , 40Mm , 50Mm , Cpvc Pipe32mm , Cpvc Pipe 40Mm , 50Mm , Providing Isi Mark Gi Pipe With One Coupler Of Following Class And Dia Including All Local And Central Taxces, Octroi, Inspection Charges, Transportation To Stores Etc. Complete. Is 1239/2004 - 15 Mm Dia Medium , 20 Mm Dia Medium , 25 Mm Dia Medium , 32 Mm Dia Medium , 40 Mm Dia Medium , 50 Mm Dia Medium , 65 Mm Dia Medium , 80 Mm Dia Medium , 100 Mm Dia Medium , 125 Mm Dia Medium , 150 Mm Dia Medium , Lowering, Laying, Jointing G.I. Pipes And Specials Of Following Class And Dia. Including Conveyance From Stores To Site Of Works, All Labour, Giving Satisfctory Hydraulic Testing Etc. Complete. Either Underground Or In Vertical Position, As Directed By Engineer-In-Charge.- 15 Mm Dia Medium , 20 Mm Dia Medium , 25 Mm Dia Medium , 32 Mm Dia Medium , 40 Mm Dia Medium , 50 Mm Dia Medium , 65 Mm Dia Medium , 80 Mm Dia Medium , 100 Mm Dia Medium , 125 Mm Dia Medium , 150 Mm Dia Medium , Providing, Supplying Isi Mark C.I.D/F. Reflux Valve (Non Return Valve ) With Jointing To Pipe Work(Including All Hardware And Packing) Water Works Quality With Jointing To Pipe Withoutbypass Arrangement With Gunmetal Seat Excluding C.C. Foundation/Structural Steel Supports. For Rating Pn - 1.6 Confirming To Is - 5312: 1984 - 50 Mm Dia , 65 Mm Dia , 80 Mm Dia , Lowering, Laying And Jointingin Position Following Cidf Reflux Valve/ Butterfly Valve And Sluice Valve Including Cast Of All Labour, Jointing Material Including Nut Bolts And Giving -50 Mm Dia , 65 Mm Dia , 80 Mm Dia , Nrv Valve Gun Metal 25 Mm , Nrv Valve Gun Metal 80 Mm , Providing And Supplying Isi Standard C.I. Flanged / S & S Specials Including All Taxes (Central And Local) Railway Freight, Insurance, Unloading From Railway Wagon, Loading Into Truck, D.F.Specials80 Mm To 300 Mm Dia , Supplying And Erecting Automatic Control Panel For 3Ph,415V ,Ac Submersible /Centrifugal Pumpset Upto 6 Hp Consisting Of Dol Starter Having Relay Range 9-14 Amp S.P.P.,Combined Ammeter/Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Encloser With Ip 54 Protection Control Panel Should Offer Single Phase ,Phase Reversal ,Phase Inbalance Etc ( Similer To Lt Model No.Mu G6/Cat No.Ss97756) , Dol Starter- Supplying And Erecting Dol Starter To Operate Squirrel Cage Induction Motor Working On 380 - 440 V, 3 Ph., 50 Hz., With No Volt Coil, Overload Element With Necessary Material & Connected To Supply Etc. Comp. Starter With Original Sheet Steel Encloser. - Up To 7.5 Hp , Up To 10 Hp , Main Switch 415V -16A , Main Switch 415V- 32A , Main Switch415v-63A , S.S. Nipple , Dual Chamber/Special Water Chamber , Providing Structural Steel Work In Single Stanctions Composed Of Rsj Chanel Etc. With Caps, Bases, Mild Steel Plates Angles, Bracket Cleats, Gusset Plates, Anchour Bolts Etc. As Per Detailed Drawing And Design Or As Directed By Engineer-In-Charge Including Cutting, Fabricating, Hoisting, Erecting, Fixing, In Position Making Reveted/Bolted/Welded In Connection And One Coat Of Anti Corrosive Point And Over It Two Coats Of Oil Painting Etc. Complete.-7.5 Hpto 12.5H.P. , Above12.5 Hpto20h.P. , Above 20 Hpto25h.P. , Above 25 Hpto40h.P. , Providing Structural Steel Work In Single Stanctions Composed Of Rsj Chanel Etc. With Caps, Bases, Mild Steel Plates Angles, Bracket Cleats, Gusset Plates, Anchour Bolts Etc. As Per Detailed Drawing And Design Or As Directed By Engineer-In-Charge Including Cutting, Fabricating, Hoisting, Erecting, Fixing, In Position Making Reveted/Bolted/Welded In Connection And One Coat Of Anti Corrosive Point And Over It Two Coats Of Oil Painting Etc. Complete. , Earthing For Pumping Machinery Supplying And Erecting Earthing With Galvanised Cast Iron Earth Plate Size 60X60x0.6 Cm Complete With All Materials,Testing &Recording The Result As Per Specification No.Ea-Ep , Excavation For Foundation / Pipe Trenches In Earth, Soil Of All Types, Sand, Gravel And Soft Murum, Including Removing The Excavatedmaterial Upto A Distance Of 50 Metres And Lifts As Below, Stacking And Spreading As Directed, Normal Dewatering, Preparing The Bed For Foundation And Excluding Back Filling, Etc. Complete. Lift 0-1.5 M. , Excavation For Foundation / Pipe Trenches In Hard Murum, Including Removing The Excavatedmaterial Upto A Distance Of 50 Metres And Lifts As Below, Stacking And Spreading As Directed, Lift 0-1.5 M. , Providing And Supplying In Standard Lengths Isi Mark Rigid Unplasticised Pvc Pipes Suitable For Potable Water With Unplastised Pvc Pipes Suitable For Potable Water With Solvent Cement Joints Including Cost Of Couplers, As Per Is Specification No. 4985 / 1988 Including All Local And Central Taxes, Transportation, Freight Charges, Inspection Charges, Loading, Unloading, Conveyance To The Departmental Stores/ Site And Stacking The Same In Closed Shed Duly Protected From Sun Rays And Rains Including Cost Of Jointing Material I.E. Solvent Cement, Etc.Complete (Selffit Type To Be Jointed With Cement Solvent).-63 Mm Dia. Pvc 4 Kg/ Cm² , 75 Mm Dia. Pvc 4 Kg/ Cm² , 90 Mm Dia. Pvc 4 Kg/ Cm² , 110 Mm Dia. Pvc 4 Kg/ Cm² , 140 Mm Dia. Pvc 4 Kg/ Cm² , Lowering, Laying And Jointing Pvc Pipes And Specials Of Following Class And Diameter Including Cost Of Conveyance From Stores To Site Of Work Including Cost Of All Labour, Material, Except Cement Solvent, Rubber Ring, Giving Satisfactory Hydraulic Testing As Per Is Code, Etc. Complete (With Cement Solvent Joint / Ring Fit Joint)-63 Mm Dia. Pvc 4 Kg/ Cm². , 75 Mm Dia. Pvc 4 Kg/ Cm² , 90 Mm Dia. Pvc 4 Kg/ Cm² , 110 Mm Dia. Pvc 4 Kg/ Cm² , 140 Mm Dia. Pvc 4 Kg/ Cm² , Providing And Laying In Citu C.C. Of Of Trap / Granite/ Quartzite/Gneiss Metal For Foundation And Bedding Including Normal Dewatering, Formwork, Compacting And Curing, Finishing, Etc.Complete. Pcc M -100 For Reinstaining Of Cement Road , Providing And Constructing Two Taps Standpost As Per Type Design With Excavation 15 Cm Thick Pcc (1:3:6) Bedding 20 Mm Thick Pcc (1:2:4) Concrete For Platform Of 1.75 M Dia. With Side Curb And Bucket Rest 80 Mm Dia, Heavy Duty Gi Pipe Central Post Duly Filled Therein With C.C. (1:2:4) 5 M Long, 20 Mm Dia. Medium G.I. Pipe From Point Of Tapping To Standpost Additional 20 Mm Dia G.I. Pipe Fixed Verticaly Upto 15 Mm Dia Self Closing Water Taps On Brass Ferrule Etc. Complete Together With All Labour And Material Charges As Per Drawing And As Directed By Engineer-In-Charge When Good Foundation Is Available. Rate Includes Draining Arrangement By Excavating Open Gutters. , Refilling The Trenches With Available Excavated Stuff With Soft Material First Over Pipeline And Then Hard Material In 15 Cm Layers With All Leads And Lifts Including Consolidation, , Providing,Hosting And Fixing In Position Of Approved Make High Density Polyethylene Uv Stabilized Conforming To Is 12701 ,Water Storage Tank With Necessary Connections, Testinfg Etccomplete 9 Prior Approval Of Sample By Ex. Engineer Is Necessary Before Use ) Spect. No. As Directed By Engineer In Charg.For 200 To 1000 Lit. , For 1000 To 20000 Lit. , Providing Fixing 15Mm Dia Screw Down Bib Stop Tap Of Brass Including Necessory Socket Union Nut Complete (Pwd Csr 22-23 P.No. 288 I.No. 41.4 , Providing And Laying In Trenches Dia Cpvc Pipeincluding Necessary Excavation Fitting Reffilling Trenches Etc Complete Including Removing Existing Pipe Line If The Same In Pwd Chowky Or As Directed Etc Complete 1)For --15 Mm Dia , 2) For 20 Mm Dia , 3) For 25 Mm Dia , 4) For 32 Mm Dia , 5) For 40 Mm Dia
Contract Date: May 27, 2026 Contract Value : 30.00 Lakh
Government Departments No of Bidders 5
Maharashtra View Result →
13.
Power #11168099 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , St Pole 13 M- Is 410 Sp- 72 , Stay Set 16X1800 , Acsr Dog Conductor , Acsr Weasel Conductor , A.B.Cab. L.T. (3X95)+ (1X70)+ (1X16)Sq.Mm , A.B.Cab. L.T. (3X120) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Earth Rod 2540X20 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , 11 Kv Composite Polymer Pin Insulator , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Composite Polymer Pin Insulator , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Ms Channel 100X50 Mm , 33 Kv Cross-Arm 100X50 Mm V-Type , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Gi Wire 5 Mm/6 Swg , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Xlpe Cable Box 3X300 , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , 11 Kv Cable Box O/D 3X185sq.Mm , M.S. Angle 75X75x6 Mm , M.S. Angle 65X65x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , Stay Set 16X1800 , Stay Set Gi 20X1800 Mm , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , Ms Channel 100X50 Mm , Lt Abc 3X50+1X35+1X16 Sq.Mm , 33 Kv Polymer Disc Insulator (B&S) 70 Kn , 33 Kv Cross-Arm 100X50 Mm V-Type , 33 Kv Disc Fitting (B&S) Dog/Racoon 70 Kn , Disc Fitting 45 Kn (T&C) , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 33 Kv Gi Pin With Nut , M.S. Guarding Angle 1.8Mtr , 33 Kv Composite Polymer Pin Insulator , G.I. Bracing Angle 65X65x6x2700mm , Droper Channel 100X50mm , Top Channel (125X65x65x6mm) 33 Kv Line , Stay Set Gi 20X1800 Mm , 3-Ph Distribution Box , V Type X Arm Angle , 11 Kv Vcb Outgoing , Ms Angle 75X75x6 Mm , Ms Channel 125X65 Mm , 11 Kv Ct/Pt Ctr200/5Amp , 11 Kv Metering Cubical , Erection & Fixing Of Single Pole Structure Of Following Pole Of 11 Kv Line Along With X-Arm And Pin Insulator After Digging Of Suitable Pits Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , St Pole 13 Mtrs , Erection Of 11Kv Double-Pole Structure After Digging Of Suitable Pits On Following Pole With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 50X6 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Plain Cement Concrete Pole 8.5 Mtrs , Plain Cement Concrete Pole 11 Mtrs , Erection Of 33Kv Double-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Tri-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection Of 33Kv Four-Pole Structure After Digging Of Suitable Pits On St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Erection & Fixing Of 33Kv St Pole 13 Mtrs With Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 33 Kv Pin Insulator With Pin, Disc Insulator With Disc Fitting Etc., As Per Respo Drawing/Norms By Providing All Clamps Made Of M.S. Flat Of Size 65X8 Mm With Proper Size Nuts And Bolts And Stone Pad With Jumpering Etc Work, And As Per Direction Of Site Incharge. All Clamp & Nut Bolt Will Be Provided By Contractor. , Grouting Of Following St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40Mm Brick Ballast) Grouting Will Be Done In The Block Of Size (450X450)Mm X1/6Th Of Full Length Of The Support, Up To Ground Level, 300Mm Plinth Above The Ground Level With cement concrete 1:3:6 (Cement, Core Sand And Stone Grit) With Mufting As Per Drawing, Work Includes Back Filling & Proper Ramming By Providing All Required Grouting Materials, As Per Direction Of Site Incharge. , Plain Cement Concrete Pole 8.5 , Plain Cement Concrete Pole 11 Mtr. Long , Stp 13 Mtrs Long , Construction Of T/F Plinth Suitable For 160/250/400 Kva T/F (Size 2X2x1.5 Mtr) After Digging Of Earth And Construction With 14 Bag Cement, Fine Sand, Coarse.Sand, Brick Ballast, 1St Class Bricks 6000, Stone Ballast (40Mm), Ms Channel 125X65mm (54 Kg), Ms Twisted Bar 20 Mm (50 Kg) & Ramming The Same, Including Cost Of All Material & Labour, As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100/250 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , 250 Kva Transformer On Plinth , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Providing And Installation Of Maintenance-Free Chemical Earthing System For 250 Kva Distribution Transformer, Comprising Of Supply And Erection Of Approved Make Chemical Earth Electrode (Gi/Copper Bonded, Of Standard Length And Diameter) Installed In Drilled/Bored Hole Of Required Depth In All Types Of Soil, Including Backfilling With Highly Conductive Earthing Compound (Bfc/Graphite Based) To Achieve Low And Stable Earth Resistance; Providing Separate And Distinct Earthing For Transformer Body, Neutral And Lightning Arrester (If Applicable) Using Required Number Of Chemical Electrodes Interconnected Where Necessary; Construction Of Earth Pit Chamber With Brick Masonry, Plastering And Heavy Duty Ci/Rcc Cover With Provision For Watering/Inspection; Providing And Laying Of Gi Strip (E.G., 50×6 Mm) Or Suitable Copper Strip From Transformer Body, Neutral Point And La To Respective Earth Electrodes, Including All Connections With Nuts, Bolts, Washers, Lugs, Clamps And Anti-Corrosive Treatment; Testing Of Earth Resistance To Ensure Values Within Permissible Limits As Per Is/Respo Standards And Ensuring Long-Term Stability Without Frequent Maintenance; The Scope Includes Cost Of All Materials Such As Chemical Electrodes, Backfill Compound, Gi/Copper Strips, Bricks, Cement, Sand, Covers, Water, Etc., And All Labour, Drilling, Installation, Refilling, Carriage, Loading/Unloading, Handling, Testing, Commissioning And All Tools & Plants (T&P) Required For Complete And Satisfactory Execution Of Work As Per Standard Specifications And Direction Of Engineer-In-Charge. , Construction Of Safety Fencing (Ms) Size 3X3x2 Mtr. For Dist. Transformer 11/0.4 Kv Sub Station, With Supply Of Material Required For Ms Fencing (50X50x3 Mm) M.S. Wire Mesh Construction Utilizing Vertical Post Duly Grouted/Fitted In Ground/On Floor. Horizontal Angle/T-Iron To Be Fitted On Vertical Posts. Pickets (If Required) Fitted To Rail And Gate To Facilitate Entry And Exit. The Vertical Posts/Horizontal Post Shall Be Made Of M.S. Angle 65X65x6mm. Such Post Shall Be Kept Preferably At Distance Of 800-1000 Mm. And Shall Be Grounded With cement concrete Ratio 1:4:8. The Length Of Vertical Post Shall Be Sufficient To Take Care Of Fencing As Requirement At Site, And As Per Direction Of Site Incharge. (All Matreial/ Labour/ T&P Use For Construction Of Plinth Will Be Provided By Contractor) , Providing, Installing, Testing And Commissioning Of Tailless Unit Suitable For 250 Kva Distribution Transformer, Including Dismantling Of Existing Tail Connections (If Any), Supply And Fixing Of Required Lt/Ht Connectors, Busbar Arrangements, Insulated Sleeves, And Necessary Termination Accessories; Complete Modification Of Transformer Lt Side To Tailless Configuration Ensuring Proper Phase Segregation, Insulation And Mechanical Strength; Including Providing And Fixing Of Suitable Size Aluminium/Copper Lugs, Glands, Ferrules, Heat Shrink Sleeves, Pvc Insulation Tape, Nut-Bolts, Washers And All Jointing Materials As Required; Making Proper Cable Terminations, Dressing And Clamping Of Cables With Gi Clamps; Providing And Ensuring Effective Earthing Of The Tailless Unit With Gi Strip/Wire And Connecting To Existing Earthing System; Including Painting Of Modified Portion With Suitable Anti-Corrosive Paint; Complete Testing For Continuity, Insulation Resistance And Proper Load Transfer; The Work Shall Be Carried Out As Per Relevant Is Standards, Respo/Departmental Specifications And As Directed By Engineer-In-Charge; The Rate Shall Include Cost Of All Materials, Labour, Tools & Plants (T&P), Handling, Loading/Unloading, Transportation, And All Incidental Works Required To Complete The Job In All Respects. , Providing, Laying, Jointing And Commissioning Of 140/200 Mm Dia (Od) Pn-4, Pe-80 Grade Uv Stabilized Hdpe Pipe In 6.0 Mtr Standard Length By Trenchless (Hdd/Drilling) Method For Underground Cable Protection, Including Excavation Of Suitable Size Launching And Receiving Pits, Alignment And Preparation Of Bore Path, Drilling, Reaming And Insertion/Pulling Of Hdpe Pipe, Jointing By Butt Fusion/Electrofusion With All Necessary Fittings Such As Couplers, Bends And End Caps, Ensuring Proper Alignment And Leak-Proof Joints; Including Providing And Laying Of Warning Tape, Route Markers And Identification System; Complete With All Required Tools & Plants (T&P) Such As Hdd Machine, Drilling Machine, Compressor, Generator, Welding Machine, Including All Consumables, Loading/Unloading, Handling And Safe Stacking At Site; Including Dewatering (If Required), Traffic Control, Barricading And Safety Measures; Also Including Restoration Of Road, Footpath, Drain Or Any Other Surface Under Row (Right Of Way) Conditions To Original Condition And Disposal Of Surplus Earth/Muck; Complete In All Respects As Per Relevant Is Standards, Respo/Departmental Norms And Direction Of Engineer-In-Charge, With All Material, Labour, T&P, Transportation And Incidental Charges Included In The Rate. (Rate Will Be Charge As Per Actual Length Of Work) , 200 Mm Dia For 33 Kv Line , 140 Mm Dia For 11 Kv Line , Laying Of Following Cable Undergound Into Hdpe Pipe, Spare Cable Shall Be Left In The Loop Shape At Both Ends As Per Respo/Norms, As Per Direction Of Site Incharge.(Rate Will Be Charge As Per Actual Length Of Work) , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 33 Kv H.T. Xlpe Cable 3X300 Sq.Mm. , Manually Digging Excavation Of Trench Of Size 0.50 M Width × 1.00 M Depth In All Types Of Soil Including Dressing, Levelling And Disposal Of Surplus Excavated Earth Within Specified Lead As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Supplying And Laying Of Brick Masonry (Class Designated) In Cement Mortar For Side Protection, Providing And Filling Of Sand Cushioning At Bottom And Around The Laid Cable, Followed By Laying Of Plain Cement Concrete (Plain Cement Concrete) Of Required Grade For Base And Protective Covering Over Trench; Thereafter, Placing And Proper Alignment Of Xlpe Cable Within The Complete Trench, And Covering The Trench With Brick/Cc Slab Protection Including Backfilling With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; The Scope Of Work Includes Cost Of All Labour, Materials (Bricks, Sand, Cement, Aggregates, Water Etc.), Handling, Loading/Unloading, Carriage, And All Tools & Plants (T&P) Required For Excavation, Laying And Finishing Works, With All Safety Precautions, As Per Standard Specifications And Directions Of Site In-Charge. (The Firm Will Be Fully Responsible For This Work And Taking Necessary Permission), As Per Direction Of Site Incharge (Rate Will Be Charge As Per Actual Length Of Work). , Laying And Installation Of 11 Kv Grade, 3 Core × 185 Sq.Mm Xlpe Insulated, Armoured Aluminium Conductor Cable In Underground Trench In Double Circuit Formation, Including Careful Handling, Dressing And Alignment Of Cable Along The Route As Per Respo/Drawing Norms And Direction Of Engineer-In-Charge; Laying Of Cable Over Prepared Sand Bed, Maintaining Proper Spacing Between Circuits, And Ensuring Identification And Phase Marking; Providing Extra Length Of Cable At Both Ends In Loop Formation For Future Jointing/Termination (Spare Cable To Be Left In Loop Shape At Each End) As Specified; Covering Of Cable With Sand Cushioning, Protective Bricks/Tiles/Cc Slabs And Backfilling Of Trench With Excavated Earth In Layers, Watering, Ramming And Proper Compaction Complete In All Respects; Including Supply Of All Consumables Such As Sand, Bricks, Cable Markers, Route Indicators, Etc., And All Labour, Loading/Unloading, Carriage, Handling Charges, Testing Prior To Commissioning, And All Tools & Plants (T&P) Required For Safe And Proper Execution Of Work As Per Standard Specifications And Site Instructions. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, As Per Direction Of Site Incharge. , Making And Filling Of 11Kv/33Kv Cable Jointing Kit, Indoor/Outdoor Type, After Duly Plumbing And Taping Of Suitable Xlpe Cable, Providing, Fixing And Crimping Of Proper Size Good Quality Lugs, Including Cost Of Lugs And Tape Etc., As Per Respo Norms, And As Per Direction Of Site Incharge. , 11Kv Cable Jointing Kit 3X185 Sq.Mm. , 33Kv Cable Jointing Kit 3X300 Sq.Mm. , Laying , Stringing And Final Sagging Of Acsr Weasel Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying , Stringing And Final Sagging Of Acsr Dog Conductor, As Per Respo/ Drawing Norms And As Per Direction Of Site Incharge. , Laying And Stringing Of Following Lt Aerial Bunched Cable (Abc) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Lt Aerial Bunched Cable (Abc) (3×95 + 1×70 + 1×16 Sq.Mm) , Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 4Mm/ 8 Swg , G.I. Wire 5Mm/ 6 Swg , Grouting & Fixing Of Stay Set (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Stay Set (16X1800) , Stay Set Gi (20X1800) , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Dead & Clamp , Suspension Clamp , F-Bracket With Clamp , Cross Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Fuse Set Complete On 25/63/100 Kva Transformer In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Stone Pad 300X300x75 Of Approved Quality And Specified Size At Pole/Support Locations, Including Excavation Of Suitable Size Pit, Preparation Of Base, Dressing, Leveling, And Proper Placement In Line And Level As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge, Including Refilling, Ramming And Consolidation To Ensure Stability; The Scope Of Work Includes Cost Of All Labour, Loading/Unloading, Carriage, Alignment And All Incidental Works Required For Complete Execution, And All Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable M.S. Clamp, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site, And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Barbed Wire Of Approved Quality And Specification In Position, Stretched And Secured On Poles/Structures With Suitable Binding Wire, Staples, Clamps Or Other Approved Means, Maintaining Proper Tension, Alignment And Height As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing, Tightening And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Stay Insulator Of Approved Make, Type And Rating In Stay Set Assembly, Including Proper Placement Between Stay Wire Lengths, Making Necessary Connections, Tightening And Ensuring Correct Alignment And Insulation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Cutting, Jointing And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of I-Bolt Of Approved Size And Quality For Guarding Angle, Complete With Nuts, Bolts, Washers And Necessary Accessories, Including Drilling Of Holes In Angle/Pole As Required, Proper Insertion, Fitting, Tightening And Ensuring Correct Alignment And Rigidity As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of Number Plate Of Approved Size, Design And Material With Proper Painting/Printing Of Identification Number And Lettering, To Be Securely Mounted On Pole/Structure At Suitable Height Ensuring Proper Alignment And Visibility, As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fixing With Suitable Clamps, Nuts, Bolts Or Binding Wire As Required, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Necessary For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Draw Out Fuse Set Of Approved Make And Rating, Complete With All Standard Accessories, Mounted On Pole/Structure With Suitable Clamps, Nuts, Bolts And Connectors, Including Proper Alignment, Tightening And Making Necessary Electrical Connections For Safe And Reliable Operation As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage To Site, Erection, Testing And Commissioning And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment, Tackles And Testing Instruments Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing And Fixing Of 11 Kv Smc Danger Board Of Approved Design, Size And Material With Proper Statutory Warning Sign And Lettering, Complete With Suitable Clamps, Nuts, Bolts And Washers, To Be Rigidly Mounted On Pole/Structure At Required Height Ensuring Proper Alignment And Visibility As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Drilling Of Holes, Fitting, Tightening, Handling, Loading/Unloading, Carriage To Site And All Incidental Works Required For Complete Installation, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Paint And Carrying Out Painting Of Pole With Approved Quality Paint System, Including Thorough Surface Preparation By Cleaning, Scraping, Wire Brushing And Removal Of Rust, Dirt And Loose Materials, Applying Primer Coat Where Required And Finishing With Two Or More Coats Of Approved Paint Of Specified Shade, Including Marking/Numbering If Directed, Complete In All Respects As Per Respo Drawings/Standard Specifications And Direction Of Engineer-In-Charge; The Work Includes Handling, Loading/Unloading, Carriage Of Materials To Site And All Incidental Works Necessary For Satisfactory Completion, And The Cost Includes All Labour, Consumables And Minor Accessories, While All Tools & Plants (T&P), Equipment And Tackles Required For Execution Shall Be Arranged And Provided By The Contractor At His Own Construction , Construction Of Meter Room Of Internal Size 8× 8× 10 Height, Including Setting Out, Excavation Of Foundation In All Types Of Soil, Dressing And Disposal Of Surplus Earth Within Specified Lead; Providing And Laying Plain Cement Concrete Of Required Grade For Foundation Base, Followed By Construction Of Brick Masonry In Cement Mortar Of Approved Class For Foundation And Superstructure Walls Of Required Thickness, Including All Leads And Lifts; Providing Reinforced Cement Concrete Lintel And Roof Slab (Solid Slab) Of Required Thickness Using M-20 Grade Concrete With Centering, Shuttering, Vibration And Curing Complete, Including Reinforcement Steel As Per Design; Providing Internal And External Plastering In Cement Mortar Of Required Thickness, Smooth Finishing, And Curing; Providing Flooring With Cement Concrete Or Ips Finish, Including Base Preparation And Finishing; Supplying And Fixing Of Ms/Steel Door With Frame, Including Holdfasts, Hinges, Locking Arrangement And Painting; Providing Ventilators With Ms Grill, Including Fixing; Complete Internal And External Painting/Whitewashing With Approved Quality Paint; Providing Necessary Provisions For Meter Installation Such As Cable Entry Points, Sleeves, Earthing Arrangement, Foundation Bolts And Fixtures; The Scope Includes Cost Of All Materials Such As Bricks, Cement, Sand, Aggregates, Steel, Doors, Grills, Paint, Water, Etc., And All Labour, Tools & Plants (T&P), Scaffolding, Curing, Carriage, Loading/Unloading, Handling And All Incidental Works Required For Complete Construction As Per Standard Specifications And Direction Of Engineer-In-Charge. , Laying Of Power/Control Cable Of Specified Size In Trench/Duct/On Surface Along Approved Route, Including Excavation Of Trench, Sand Cushioning, Proper Dressing, Alignment, Clamping, Identification Tagging, Protective Covering With Bricks/Tiles (Where Required), Backfilling, Ramming, Leveling, And Disposal Of Surplus Earth; Including Handling, Shifting, Straightening, And Pulling Of Cable With Due Care To Avoid Damage And Maintain Required Bending Radius; Complete In All Respects As Per Standard Specifications And Direction Of Engineer-In-Charge, All Materials, Tools & Plants (T&P), Equipment And Tackles Shall Be Arranged And Provided By The Contractor At His Own Construction , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Uttar Pradesh View Result →
14.
Housing Urban and Rular Development #11162283 AOC
Providing the manpower for electrical preventive and breakdown maintenance Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033for the period of 12 months.- 1 Day to day operation & maintenance of entire electrical installations including Sub-Station, compound lighting, DG operation, dusting and cleaning of fire detection sensors and others parts, operationof liftsetc at the Technician Studio, Kolkata-700033 2 Skill Electrician: 03 Nos per day 3 Semi-Skill Electrician: 03 Nos per day 4 Un-Skill Electrician: 02 Nos. per day 5 Semi-Skill (Lift Operatror cum Attendent): 02 Nos. per day 6 SCOPE OF WORK:-1. The Scope of maintenance of electrical installation includes Routine, Preventive and Corrective Maintenance of L.T. Distribution lines to each floor of all the buildings/ blocks, entire wirings, BDB, PDB, VTPN, LT panels, Feeder Pillar Box, power & distribution cables, fittings & fixtures, Switch Boards, Power and Computer Points, Power outlet of all sorts of Air-conditioning Systems,resetting/ Switching off of Fire detection system during normal operation/ malfunctioning etc., Operation, configuration & repair / replacement of Timers for AC / Compound light, Compound Lighting including high mast, all glow sign and metal sign boards in the campus, Electrical Installations/ distribution up to Switch Board/ Panel of Lift Machine Room & Pump Room and / or Kiosk of Pump for Water Supply system, in the premises of above mentioned site. 7 2. Cleaning & checking of all the fittings & fixtures, Panels, TPN & SPN DBs, SFUs & other Electrical Installations, as well as the Compound Light installations in a regular interval to keep them in a tip-top condition at the cost of the agency and the same must be recorded in log book.3. The checking & repairing of the different types of light fittings, ceiling fans, exhaust fans etc. has to be done by the agency at his own cost (except rewinding of ceiling fans and exhaust fans) including dismantling and re-fixing of the same. (Major materials to be supplied by department). Especially, all the ceiling fans of entire worksite are to be inspected, at least once in 3(three) Months, in respect of Split Pin, Jam nut etc. to prevent unwanted falling of Ceiling Fans, failing which responsibility will be fixed up upon the agency. Split Pin, once taken out from the installation should not be re-used under any circumstances. Required number of Split Pin and Jam nut should be provided by the agency at their own cost. Building wise Fan register should be maintained as per Performa provided by the department, wherein each and every details of checking, replacement of spares, repairing etc. should be recorded against individual fan and every record should be signed by the attending Electrician / responsible person of the agency, duly countersigned by the concerned J.E. and A.E. 8 4. Measuring of various electrical parameters e.g. Current, Voltage, Temperature of different L.T. panel board, BDBs, Main switches etc., test of Insulation Resistance, Earth Resistance etc. are to be carried out every month and test results are to be recorded in Log book (preventive maintenance). Thermal Imaging Scanner should be used for measuring temperature of electrical equipment regularly to find out any abnormalities and printout of thermal image with date and time stamp should be provided to the concerned J.E. and A.E. In case, any abnormal reading is noticed, the same should be rectified/set right immediately by taking prompt, appropriate & effective measures/actions in consultation with concerned AE&JE. Thermal image should also be taken after rectification. The engaged agency will supervision overall maintenance works and examine Logbooks for any abnormality and sign the Logbook accordingly5. Switching On/Off of the common service lighting e.g. compound, corridors, staircases etc. and AC machines, Light, Fan etc in closed room like Library, Store, OPD, OT or these are not run beyond Office hours or off day will be the responsibility of the agency. 6.Cleaning of Sub-station rooms,LT Panel rooms,operation of HT switch gear & resetting the protective rekeys in case of any fault occurred will be the responsoibilty by the agency . 9 7. Operation of DG sets & checking and maintenance of AMF panel, Checking of Battery, checking of fuel level of DG Set, Lubricating oil etc, carrying & pouring of Fuel if necessary and maintaining separate log book for DG Set as per given Proforma. For Operation of DG Sets, experienced and skilled operator should be provided8.Llift operation cum attendent including regular cleaning of lifts etc as per direction of EIC.9. Regular dusting and cleaning of fire detection sensors and others parts including reset of fire alarms. 10 TERMS & CONDITIONS:-1. The agency has to depute manpower as directed by the EIC carrying out the maintenance work smoothly with due regard to the safety.Category of Staff:- i) Skilled Electrician --03 (Three) Nos per day ii) Semi-Skill Electrician--03(Three) Nos. per day iii) Un-Skill Electrician: 02 Nos. per dayiv) Semi-Skill (Lift Operatror cum Attendent): 02 Nos per day 11 2. The Maintenance Personnel, deputed by the agency havingvalid Voter Identity/ Adhaar Card and should possess valid Workman Permit/ License, as mentioned below, issued by Directorate of Electricity, Govt. of West Bengal.Category of Maintenance Personnel Mandatory Requirementa. Skilled Electrician Having Electrical/ Workman Permit i(b), ii & iv issued by Directorate of Electricity, West Bengal.b. Semi-Skilled Electrician Workman Permit i(b) and (ii) issued by Directorate of Electricity, West Bengal.c. Un-skilled Personnel/ Helper Basic knowledge of Electrical works.Also the Superviser of the company should have valid SCC Parts 1,2,3,4,5,6A,7A,7B ,9,11,12. 12 3. Agency must have to submit mandatorily the list of staff mentioning their Name, contact Mobile No., category, along with photo copy Valid Workman Permit, proper identity and address proof etc, in writing to the concerned JE & AE before commencing the work. All the photocopy should be attested and authenticated by the Agency.4) The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the Maintenance Staffs deployed including substitutes.They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE.5) The agency will maintain shift wise attendance register at call center to record the attendance of the staffs on duty which will be authenticated/ verified by the concerned Junior Engineer/ Officer- in-charge. 13 6) The agency shall have to prepare a Duty Roster of the Maintenance Staffs at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE and one copy should be available at the call centre.7)The agency will have to provide proper uniform for his maintenance staff at his own cost and clour of the dress will be decided by the EIC. No staff will be allowed for performing duty without proper uniform. 8) The agency, and all the electricians deputed at worksite must have Mobile Nos. and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay. 14 9) The agency has to provide one GPS activated smart phone dedicated for call center. The cost of the handset and running cost i.e. phone bills have to be borne by the agency. No claim of payment against any telephone bill will be entertained by this department.10) The agency should have a close watch on the attendance of the Maintenance Staffs. In case of absence of any Maintenance Staffs, the agency shall have to arrange for suitable alternative within an Hour, failing which, the charges for that day will be deducted from the bill of the agency on pro-rata basis.The Executive Engineer,Electrical Constrution Division ,P.W.D. reserves the right to terminate the contract in case of absence of Maintenance Staffs for more than three consecutive days, without showing further reason. 15 11) In case of any Accident and or physical illness of the staffs of the agency, while on duty, no claim will be entertained by this department and all responsibilities thereof should be shouldered by the agency only. Minimum wages as per existing Labor Act should be paid to the Electrician(s) and Helper(s)12) The agency shall have to provide 500V Megger, Digital Multi meter, Earth tester and all other requisite tools and tackles sufficient for checking, testing and recording of health of all electrical installations. Other tools & tackles e.g. Crimping Machine, Line Tester, Screw Driver, Pliers, Stripper, Sockets of some common sizes etc. should also be available at site, in sufficient quantities, free of cost, under disposal of their maintenance staff.Deployed employee by the agency should have sufficient knowledge to operate The Thermal imaging Scanner or to be used by the direction of Assistant Engineer/ Junior Engineer.13) The space for sitting accommodation for the staffs of the agency inside worksite premises will be provided by the competent authority. 16 14) All the maintenance staff of the contractor should have proper & constant vigilance and check that, there is no sign of heating-up, burning smell, discoloration or sparking at any of BDBs, panel boards, rising main etc. due to overloading or loose termination. Care should be taken to check any highly unbalance in loading at any point.15) In case of power failure or development of any unfavorable situation the agency will have to communicate with the concerned Power Supply Company authority and extend help or cooperation to said authority in restoration of power supply. Meanwhile the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supplies at important locations by monitoring and/ or restricting electrical loads in consultation with the concerned Junior Engineers & Assistant Engineer.16) Routine checking and preventive maintenance and breakdown maintenanceof the electrical installations has to be carried out by the agency maintaining a register under signature of respective Junior Engineer and Assistant Engineer with a view to ensure uninterrupted power supply within worksite campus. 17 17) Materials required as replacement during maintenance of electrical installations e.g. Lamps, SFUs, SPNDB, TPNDB, Cables etc. will be supplied by the Department for which requisition of Materials, signed by the authorized representative of the agency, should be submitted to the concerned JE (Electrical) well in advance. A separate material stock register should be maintained by the agency where entries related to Issue, Consumption & present stock position of Materials should be made. However auxiliary items like fuse wires, screws, nuts, bolts, washers, insulating tape, Split pins of Ceiling Fans, dusters etc. will have to be supplied by the agency at his/ their own expense.18) The agency shall have to deposit all dismantled unserviceable materials such as fused lamps, defective condensers, starters, and timers, MCBs etc. to the concerned Section Office or any other locations within worksite premises by the agency by its own laborers / arrangements / tools and tackles as per the direction of the Assistant Engineer/ JE concerned. Fresh materials will be issued against respective defective materials. No materials should be taken out of the maintenance site without the permission and necessary challan of the site-in-charge/JE 18 19) Any major shut down or fault should be brought to the notice of JE/AE immediately in writing and over telephone for further course of action. The agency will also have to attend emergency calls immediately at the site with staff, tools etc. on demand. 19 20) In case of any breakdown caused by cable fault etc., if situation demands the agency will have to restore the power supply temporarily either with the materials available with this department or arranging the same temporarily and safely at his own cost till completion of original restoration work.21) Building wise Log book is to be maintained for Preventive Maintenance & Cleaning and Corrective Maintenance of Electrical equipment except Fan as per direction of E.I.C. Separate Building wise Register is to be maintained for Ceiling Fans. The daily record of the Log book is to be signed by the responsible person and verified & signed by concerned JE & AE and photocopy of the same should be sent to the Executive Engineer concerned through proper channel at the time of submission of bills. The Logbooks should be available at Call center and should be produced on demand. 20 21) The agency should be responsible for any damage in the installation due to mishandling or mal- operation by its staff and shall be liable for rectification / replacement, as the case may be, of the damaged installation/ equipment within time frame to be fixed by concerned A.E., failing which the said rectification/ replacement of affected equipment/ installation would be executed by external agency and the cost thereof would be recovered from the bill and the accused staff should be replaced immediately.22) Bills should be submitted quarterly with the certification of satisfactory performance of the concerned JE and AE. Photocopy of Logbook and Attendance Register should also accompany the Bill. Payment should be made as per PWD norms. 21 23) Any fault of electrical installations starting from LT supply end (except the installations of Power Supply Company) to light, fan, call bell, plug points etc. i.e. LT cables and all sub-panels, distribution boards, main switches, earthing attachments, compound lights etc. has to be detected, attended and restored by the agency by its own man power with the help of the materials(cables, main switches, DBs, wires, HRC fuses etc.) available from this department or as per the terms & conditions of this contract. 24) If any kind of incapability & negligence are noticed in observing all the above-said terms & conditions causing inconveniences to public service, is subject to unilateral penalty, be it detected on the spot or thereafter (even after payment). This Department also reserves the right to deduct the cost from the bills of the contractor on pro-rate basis as determined by the Engineer –In-Charge for any shortfall in observing above T&C. In that case, the above- said contract may be terminated without issuing any notice and Stringent & punishable action may be taken against the contractor. 22 25) The technitian of the agency should capable of Casing -caping /rigid conduit wiring to overcome the emergent situation .25) The contract may be terminated with one months’ notice on either side (both agency and tender awarding authority) . 26) At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .27) Any upcoming / Ongoing project, which will be completed within stipulated period of Maintenance contract, automatically will come under maintenance contract .28) All the log-books should be available at the call center and to be produced to the Office of the AE/ JE on demand. 29) This Maintenance contract covers all the buildings, blocks, outdoor electrical gadgets within the premises ofTechnician Studio, Kolkata-700033 23 TERMS & CONDITIONS FOR OPERATION OF LIFTS:- 24 1. The agency has to depute manpower as directed by the EIC carrying out the lift operation smoothly with due regard to the safety.Category of Staff:- Semi-Skill (Lift Operatror cum Attendent): 02 Nos. 25 2. Day to day Attendent -cum -operation of passenger lift foras directed by the EIC.3. The lift operator/attendant should have a sound knowledge with valid lift operator license issued by the Licensing Board, Govt. of West Bengal.4. The operator/attendant should be obliging dutiful and polite to all while on duty. In case any irregularities of duty or complain against the operator/attendant if noticed, would be withdrawn forthwith and shall be replaced by new operator.5. The report is to be submitted periodically about the working of lift incl. all safety devices and Governor to the concerned JE/AE. 26 6. Agency must have to produce the list of the staff mentioning their Name, contact Mobile No.in writing with proper identity and address proof & their Valid lift operator license issued by the Licensing Board, Govt. of West Bengal along with photo copy to the concerned JE & AE before commencing the work. This should be treated as mandatory.7. The agency will have to provide proper dress for his staff and color of the dress will be decided by this department. No staff will be allowed for performing duty without proper dress.8. The agency will issue a photo Identity Card, duly signed by the agency and countersigned by the concerned JE / AE to all the operation Staffs deployed including substitutes. They should always carry the said Photo Identity Card while on duty. The agency should also submit one copy of the said Identity Cards to the JE 27 9. The agency shall have to prepare a Duty Roster of the operation Staff at the beginning of every month, or as directed from time to time. A copy of the said Duty Roster, duly signed by all staffs, should be submitted to the concerned JE.10. The agency must have separate contact telephone numbers with Mobile Nos. for his office and Supervisor deputed at worksite so that the agency may be communicated in case of any urgency and the same should be intimated to the E.I.C., A.E. & J.E concerned, in writing. The telephone call should be responded without delay.11. The lift enclosure to be kept clean (not sweepers works) regularly by the operator 28 12. The operational work of the lift is to be supervised directly under the supervision of technical staff of the contractors under the direct control of JE/AE concerned. The contractor shall be responsible for any damage to the lift due to mishandling; loss will be recovered from the contractors bill as per direction of EIC.13. The Log Book recording regarding functioning and breakdown of the lift is to be maintained at site by the contractor under supervisions of JE concerned. If any kind of trouble arises, it should be brought to the notice of JE, AE concerned immediately. The JE/AE would put their signature on log book making note on performance. 29 14. In case of any absence of operator, the lift is to be made operative within 2 hours by placing the new operator. In case of absence prorate deduction will be made from the contractors bill and the contract may be terminated if it exceeds 3 (three) days. In this respect Executive Engineer’s decision will be final.15. This department would not be held responsibility for any accident of the liftman on duty for any reasons. The contractor or their lift operators on duty would not claim any compensation in any shape from this department for such accident. 30 16. The Executive Engineer,Electrical ConstructionDivision, P.W.Dte. would have sole authority to cancel the contract without assigning any reason with a notice of one month only.17. Any conditional quotation offered would not be accepted.18. Any quotation offered with price variation clause would not be accepted.19. The payment will be made monthly/quarterly on submission of bill in triplicate by the agency with satisfactory report regarding performance by the concerned JE/AE. Copy of log book has to be enclosed with the bill. 31 20. Persons entrusted by the agency for operation of lift should wear photo Identity Card during duty hours.21. Documentary evidence in support of payment of minimum wages as per Labour Act to be produced to the Principal Employer i.e. Executive Engineer, Electrical Construction Division, P.W.Dte. in-charge of works.22. Rescue operation is in the scope of agency in case of exigency arises out of lifts getting stopped in between landing floors with passengers inside cage.23. No claim towards cost of uniform, PPE e.g. Hand Gloves, Mask, Goggles, protective body- ware etc. for the maintenance staffs should be entertained by this department. However, if any such equipment/ dress is available from the Hospital Authority for their statutory requirement, the same would be provided. BUT IN NO CASE IT SHOULD BE ENTERTAINED AS MANDATORY CLAIM.24.At the time of Bill submission must submit payment acquaintance of staff wages ,ESI & PF in which signature of each staff with revenue stamp is necessary .
Contract Date: Mar 09, 2026 Contract Value : 14.46 Lakh
Government Departments No of Bidders 4
West Bengal View Result →
15.
Public Administrative Department #11162234 AOC
Providing Fixing Various Equipments And Appliances, Cctv, Water Purifier Etc And Electrification Work In Zakir Hussain Hospital, Nmc-1 P / F Isi Mark Midget Type 3.0 Ltr Instant Type Water Heater Of Abs Plastic Body Kw, Heating Element 230 / 250 Volts 50 Cycle Ac Supply With Inlet And Outlet, Thermostatic Control And Thermal Cutoff With 3 Core Pvc Flexible Wire Leads Complete 2 P / F, Testing And Commissioning Of 1400 Va To 1600 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete As Per Specification No. Apinv ( Without Batteries ) 3 P / F Testing And Commissioning Of 2500 Va Digital Pure Sine Wave Inverter Based On Insulated Gate Bipolar Transistor ( Igbt ) Technology Single Phase 230V, 50 Hz Complete 4 P / F 12 V / 150Ah Battery With Battery Terminal Wire, Duly Charged Complete 5 P / F 12 V / 180Ah Battery With Battery Terminal Wire, Duly Charged Complete 6 P / F, Testing And Commissioning Split Type Variable Speed Inverter Technology Room Airconditioning Unit 1 Tr Having Iseer Minimum 4.50 Suitable To Operate On Capacity 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall Floor Mounting Type Complete With Refrigerant R410a / R32 And Copper Condenser At Position. 7 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 1.5 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C.Supply Having 1 No Of Air Handling Unit Hiwall / Floor Mounting Type Complete. 8 P / F Testing And Commissioning Split Type Variable Speed Inverter Technology Room Air Conditioning Unit 2 Tr Capacity Suitable To Operate On 250V, 50 Cycles, A.C. Supply Having 1 No. Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete 9 P / F Testing And Commissioning Of Etc Solar Water Heating System Without Heat Exchanger Type Of 500 Lpd Capacity Complete. 10 P / F Ultra Violet Storage Type Water Purifier ( Ro+Uv+Uf ) With Softener For Safe Drinking Water Consisting Of Uv Germicidal Tube Of 8W Capacity Choke Made Of Copper Wire And Two Indicator Lamps . 11 P / F 2 Mega Pixels Ip Dome Progressive Scan Image Sensor Camera With Awb / Agc / Blc Onvip 2.4 With Ip 66 Weather Proof Housing Supports Poe. 12 P / F 4 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 2Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 13 P / F 8 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocol- Tcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp 14 P / F 16 Channel Networking Video Recorder H. 264 .1080P, With One Vga & Hdmi Out, Resolution Ntc 1080P Pal 1080P Real Time Recording Sata Support Capacity 4Tb, 2Usb Port, Protocoltcp / Ip, Dhcp, Ddns, Upnp, Ntp & Smtp. 15 P / F Hard Disc Drive Of 4 Tb Capacity For Network Video Recorder 16 P / F 1Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 17 P / F 2Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 18 P / F 3Kva On Line Ups Pure Sine Wave With Standard Features, Along With Necessary Smf Batteries For 30 Mins. Battery Backup 19 P / F Testing And Commissioning 32 Hd Led Tv With 1366X768 Hd Ready- Great Picture Quality, 60 Hz : Standard Refresh Rate For Blur Free Picture Quality, Etc Complete 20 P / Laying Cat-6 Cable With Rodent Proof Suitable For Lan / Wan 21 P / F Testing Utp Connector ( Rj-45 ) 22 P / F And Configuring Broadband Router With All Accessories, On Provided Rack . 23 P / F And Configuring 8-Ports Managed Gigabit Switches Poe Smart Switch 24 P / F 6U Wall Mount Rack ( Dimension- Dxwxh – 450X550x367 Mm ) 25 P / Laying Hdmi Cable Low Voltage Grade As Per Specification As Per Specifications Having 5 Mtr Cord Length With Male / Female 19Pin Hdmi Connectors As Per Requirements Complete. . 26 P / F Testing And Commissioning Tata Sky Connection With 3 Month Recharge ( Tata Sky Connection 2100 / - + 3 Month Recharge ( Basic Marthi & Hindi Package ) 1050 / - 27 Recharge Of Set Top Box Connection ( Basic Marathi & Hindi Package ) 28 Recharge Of Broadband Connection 29 Making Plumbing Works On Terrace For 500 Lpd Solar Water Heating System Complete 30 Providing, Erecting Hand Dryer ( As Per Product Price Abs Hand Dryer ) 31 P / F Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25 Mm With Accessories On Wall / Ceiling . 32 Point Wiring In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Copper Wire, Modular Type Switch, Earthing And Required Accessories 33 Point Wiring For Independent Plug In Pvc Trunking ( Casingcapping ) With ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories . 34 P / F T8 Led 20W Tube Light Fitting ( 4 Feet ) With Aluminium Housing, Heat Sink, Integrated Hf Electronic Driver Complete . 35 P / F Centrifugal Mixer Domestic Type, Ss Container, Motor Suitable For 230 / 250 Volts Single Phase, 50 Cycles A.C. Supply Complete 36 P / F 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 37 P / F 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base . 38 P / F Regular / Standard Model Ceiling Fan Complete Erected In Position 39 P / F Fan Clamp Of 30 X 5 Mm. M.S. Flat Of Required Length And 10 Mm. M.S. Bolt And Nuts Erected With Necessary Hook Of 10 Mm. M.S. Round Bar And Painted. 40 P / F ‘B’ Grade G.I. Pipe / M.S. Pipe Down Rod Duly Painted For Fan Complete Erected With Pvc Three Core Flexible Cable 1 Sq. Mm Copper Pvc Wire. 41 P / F Isi Mark Modular Type Electronic Step Regulator For Fan 42 Providing Aaa Batteries For Various Equipments As Required. 43 P / F Good Knight Machine For Mosquito Repellant Liquid. 44 P / F Refill For Good Knight Machine. 45 P / F Floor Cleaning Vaccum Cleaner Suitable For Operating On 240V / 50Hz Power Supply Complete. 46 P / F 3Kw Electrical Heater Coil With Anode, Thermostat, Auto Panel With Timer Etc Complete Suitable For 500 Ltr Solar Water Heating System Complete. 47 P / F Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation 48 P / F 400Mm Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete 49 Providing And Fixing 2 X 1.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 50 P / F 2 X 2.5Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 51 P / F 2 X 4Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 52 Providing And Fixing 2 X 6Sq.Mm Mains With Copper Pvc Stranded / Solid Wire Complete 53 P / F Isi Mark Modular Type Switch 6A 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete 54 P / F Isi Mark Modular Type 3 Pin 6A Multi Sockets With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 55 P / F Isi Mark Modular Type 3 Pin 6 / 16A Multi Socket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete 56 P / F Isi Mark Modular Type Switch 16 / 20 A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete 57 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 3 Modules Duly Erected 58 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected 59 P / F Pvc Surface Modular Switch Box With Double Mounting & Front Plate For Modules Complete Duly Connected 60 P / F Pvc Surface Modular Switch Box With Double Mounting Plate For 12 Modules Duly Erected 61 P / F Double Pole Switch Surface Type / Flush Type 240V, 32A With Indicator Lamp & Fuse 62 Providing Fixing Marking Spmcb 6A To 32A, B- Series In Provided Distribution Board 63 Providing Fixing Marking Spmcb 40A To 63A C- Series In Provided Distribution Board 64 Providing Fixing Marking Dpmcb 6A To 32A, C- Series In Provided Distribution Board 65 Providing Fixing Marking Dpmcb 40A To 63A, C- Series In Provided Distribution Board 66 Providing Fixing Marking Tpmcb 6 A To 32A In Provided Distribution Board 67 Providing Fixing Marking Tpmcb 40A To 63A In Provided Distribution Board 68 Providing Fixing Marking Fpmcb 6 A To 32A In Provided Distribution Board 69 Providing Fixing Marking Fpmcb 40A To 63A In Provided Distribution Board 70 P / F Meter Box For Three Phase Energy Meter With Compartment For Mccb / Mcb Etc Complete. 71 Making Trench In Soft Soil For Laying Provided Cable . 72 P / F Single Door Refrigerator Domestic Type Of 270 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 73 P / F Two Option Coffee / Tea Vending Machine Operating On 50 Hz, 230 V Single Phase A.C. Supply. 74 P / F Three Option Vending Machine For Coffee / Tea Operating On 50 Hz, 230 V Single Phase A.C. Supply. 75 Providing Premix Of Tea / Coffee For Vending Machine Refillng. 76 P / F Single Door Refrigerator Domestic Type Of 215 Litres Storage Capacity, Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 77 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 50 Cu.M Per Minute, With 12 Exhaust, Minimum 40 To 55 Litre Water Capacity Tank Complete. . 78 Providing Evaporative Air Cooler 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 60 To 70 Cu.M Per Minute With 15 Exhaust Fan, Minimum 68 Litre Water Capacity Tank Complete. . 79 Providing Evaporative 230 / 250 Volts, 50 Cycles, Normal Cooling Capacity Of 80 Cu.M Per Minute With 18 Exhaust Fan, Minimum 75 To 80 Litre Water Capacity Tank Complete. 80 Providing Basic Feature Mobile Set For Coordination Of Security And Building Coordinators / Ward Boys. 81 Making Plumbing Works For Fixing Instant Water Heater / Gryser / Water Purifier Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 82 Making Plumbing Works For Fixing Storage Water Heater / Gryser Using Various Aacessories Like Pipes, Valves, Tapes Etc Complete. 83 P / Pasting Superior Quality Sun Control Film On Glass To Achieve Better Cooling Effect 84 P / Laying Telephone Black / Amba White Cadburybrown / Ruby Red / Ocean Brown Granite Stone Of 18 To 20 Mm Thick For Door Frame / Dado / Window Boxing Etc. On C.M. 1:6 Including Filling Joints With Polymer Base Filler Nosing / Moulding 85 Providing, Constructing Plinth For Substation Compound Required Excavation, Pcc In 1:2:4, 0.5Mtr Wide, 0.5Mtr Below And 0.5Mtr Above Ground In Cement Morter 1:6, Etc Complete As Per Rate Analysis. 86 P / F Fencing Of Section Having Size 2450 Mm In Height From Ground Level And 1200 Mm Width With Angle Iron Frame Work Complete 87 P / F Double Leaf Hinged Door Each 1500 Mm In Width X 1850 Mm In Height Using B Class, Gi Pipe With Angle Iron Supports, Chain Link Wire Meshcomplete 88 P / F 50 X 50 X 6Mm Angle Iron Corner Support 0.5M Away From Fence Support Fixed Etc. 89 P / F Gi Sheet 0.6 Mm ( 24 Swg ) To Be Used For Fabrication Of Boxes Panel Boards Etc. Including Cutting, Bending, Drilling, Welding, Riveting Etc. Complete . 90 P / F Marine Plywood 18 / 19 Mm Thick Fixed To Wall Or On Provided Panel Board With Necessary Materials Such As Screws, Wall Fasteners, Supports, Nut Bolts Etc. Complete. 91 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 92 Powder Coating In Siemens Gray Colour . 93 Making Iron Work For Fabrication With Bending, Cutting, Drilling And Welding Complete . 94 Providing And Applying Epoxy Paint With Anticorrosive Coating Etc Complete 95 Making Fabrication Work Using 16 Gauge Metal Sheet With Bending, Cutting, Drilling And Welding Complete . 96 Providing , Fixing And Erecting 6Mm Polycarbonate Multiwall Ultravoilet Protected Sheet For Roofing Over Fabricated Steel Structure As Per Detail Design, Including Fixing The Polycarbonate Sheet With Alluminium Angle & Flat Anodized & Dyed As Per Approved Shade Including All Water Proofing Materials, Nuts Bolts Hardware, Labour & Square Pipe, Angles, Fabrication Complete Including All Hardware Etc. As Required . ( Only Actual Area Of Polycarborted Sheet To Be Considered For Measurements ) 97 P / F Bracket For Set Top Box 98 Providing Stainless Steel Electric Kettle 99 P / F Co-Axial Copper Cable Low Voltage Grade Rg-11 100 P / F And Modifying Rfid / Coin System For Vending Machine Complete. 101 Providing Rfid Card / Coin For Vending Machine Complete. 102 Providing Hot Water / Tea / Coffee Storage Can Of 6 Litre Capacity. 103 P / F Water Cooler With Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 104 P / F Water Dispenser In Hot & Cold With Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 105 P / F Water Cooler With Ro + Uv Water Purification System Complete Of 120 Lit Capacity Pss Storage Suitable Operating Input Voltage 240 V 50 Hz Power Supply Complete. 106 P / F Water Dispenser In Hot & Cold With Ro + Uv Water Purifier Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 107 P / F Insect Killer Suitable Operating Input Voltage 230V / 50Hz Power Supply Complete. 108 P / F Single Door Horizontal Chest Deep Freezer Of 200 Litres Capacity, Direct Cool Technology Suitable For Operation On 230 / 250 V, 50 Cycles Complete With Automatic Temperature Control Sealed Unit In Refrigeration System Complete. 109 Carrying Out Core Cutting Of Size 3 To 5 Dia X 1 Length In The C.C. / Rock / Stone Wall With The Help Of Pecialized Core Cutting Machine In Proper Manner And Finishing The Site As Original. 110 P / F H.D.P Container Syntex Or Alike One Piece Moulded Water Tank Made Out Of High Density Polythyler And Built Corrugated Complete. 111 P / F Iam 15V Oil Free Medium Pressure Air Compressor Reciprocating Vertical Type Water Cooled Non Lubricated With Suction Air Filter With Silencer Watercooled After Cooler With Moisture Separator V-Belt Drive Arrangement Complete. 112 P / F Cooling Tower 10 Tr 113 Making Foundation, Water And Air Pipe Line With Complete Power And Control Cabling Loading, Unloading Trasportation, 114 P / F Automatic Control Panel For Emergency Alarm System Complete. 115 P / F Copper Pipe Suitable For Refrigeration System Having Size 12 Mm Complete. 116 P / F Copper Pipe Suitable For Refrigeration System Having Size 16 Mm Complete. 117 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 12 Mm 118 P / F Elastomeric Nitrile Rubber / Foam Tube Type Sleeves For Over Coating And Insulating On Provided Copper Pipes Having Sizes 16 Mm 119 P / F Rigid Pvc Pipe 20 Mm Dia.With Pvc Accessories For Drain 120 P / F Mains With Isi Mark Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete 121 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 122 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 123 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 124 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 7.5 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 125 P / F Fully Automatic Line Voltage Stabilizer For Operation On Input Voltage 160 To 270V And Output Voltage 200 To 250V Rated For, 10 Kva Maximum Load And With Voltmeter, Selector Switch, 6A / 16A Flush Type 3 Pin Socket For Output 126 P / F Testing & Commissioning Approved Type Digital Key Telephone / Ip Telephone Instrument 127 P / F Testing & Commissioning Internet Protocol Digital Type Epabx For 10 Ip Extensions Complete. 128 P / F 8 Extension Card For Epabx System 129 P / F 16 Extension Card For Epabx System 130 P / F Testing & Commissioning Push Button Telephone Instrument Desk Top / Wall Mount With Caller Id Unit, Etc Complete . 131 P / F Commissioning Main Distribution Frame ( Mdf ) Box 50X50 Pairs 132 P / Laying Telephone Copper Cable 4 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit . 133 P / Laying Unarmoured Telephone Copper Cable 10 Pair With 0.5 Mm Dia. Laid In Provided Pvc Casing Capping / Conduit 134 P / Laying Lszh Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 135 P / Laying Fr Grade, Pvc Armoured Multimode Armoured Multimode Optical Fibre Cable With 6 Fibres, With Core Dia 50 / 125 Lm Suitable For 1 Gbps Ethernet Distance At 850 Nm Of Wavelength, On Wall / Ceiling Or Laid In Provided Pipe / Trench 136 P / F Configuring 1-Port Mini-Gbic Sx Mutlimode Fibre Transceiver 137 Supplying, Erecting, Testing And Commissioning Amplifier 700 W For Public Address System Suitable To Operate On 230 Volts A.C. / 12 Volts D.C. Supply Complete. 138 P / F Testing And Commissioning Sound Column 30 Watts Complete. 139 P / F Testing And Commissioning Microphone Complete 140 P / F Testing And Commissioning Stand For Microphone Complete. 141 P / F Testing And Commissioning Of 2 Core Shielded Microphone Cable Complete 142 P / F Testing And Commissioning Of 1.5 Sq Mm Speaker Wire Complete. 143 P / F Digital Ammeter For Measuring Current 144 P / F Digital Voltmeter For Measuring Voltage 145 P / F Multifunction Meter 146 P / F Selector Switches For Voltmeter & Ammeter . 147 P / F Light Emitting Diode Type Indicator 148 P / F Moulded Case Circuit Breaker . A Up To 100A. B 200A. C 250 D 315 / 400A. E 600 / 630A. F 800A. 149 P / F Sp Moulded Case Circuit Breaker. A Up To 100A. B 200A. 150 P / F Busbar Chamber With Triple Pole Neutral Aluminium Bus Bar A 100A. B 200A. C 300A. D 400A. E 630A. F 800A. 151 Providing And Laying Aluminium Conductor 3.5 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 25Sq.Mm B 35Sq.Mm C 50Sq.Mm D 70Sq.Mm E 95Sq.Mm F 120Sq.Mm G 150Sq.Mm H 185Sq.Mm I 240Sq.Mm J 300Sq.Mm K 400Sq.Mm 152 Providing And Laying Aluminium Conductor 4 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm D 16Sq.Mm 153 Providing And Laying Aluminium Conductor 2 Core Xlpe / Pvc Armoured 1.1Kv Grade Cable A 4Sq.Mm B 6Sq.Mm C 10Sq.Mm 154 Providing And Laying Copper Conductor Core 2.5Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 155 Providing And Laying Copper Conductor Core 4Sq.Mm Xlpe / Pvc 1.1Kv Grade Flexible Cable 156 Providing And Laying Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete A 50 Mm B 75 Mm C 90 Mm D 120 Mm E 146 Mm F 160 Mm G 175 Mm H 200 Mm 157 P / F Heat Shrinkable Straight Through Joint Kit For 3 Core Etc Complete . A 70-120Sq.Mm B 150-185Sq.Mm C 240-400Sq.Mm 158 P / F Gi Strip Of Suitable Size 159 P / F M.S. Stand For Fire Bucket 160 P / F Wall Hook For Fire Bucket . 161 P / F G.I Fire Bucket 9Lit 162 P / F Instruction Chart 163 Pair Of Rubber Hand Gloves 164 Providing Standard First Aid Box With Necessary Antiseptic Cream, Medicine For Use On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Use Bandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc 165 P / F Fire Extenguisher Complete Erected With Necessary Clamp 166 P / F High Voltage Insulating Electromat Confirming To Is 15652 :2006 A Suitable For 3.3Kv. B Suitable For 11Kv. C Suitable For 33Kv. 167 Danger & Other Sign Board 168 Electrical Inspection, Compliance, Test Reports Of Earthing, Insulation Test Etc Complete. 169 P / F Analog Ammeter For Measuring Current 170 P / F Analog Voltmeter For Measuring Voltage 171 P / F Change Over Switches. A 63A. B 125A. C 200A. D 250A. E 315A. F 400A. G 630A. H 800A. I 1000A. 172 P / F C I Pipe Type Earthing Etc Complete. 173 Lt Panel, Changeover Panel, Distrubution Panel, Feeder Panel A Power Wiring Up To 63A Feeder Using Copper Wire, Lugs, Tie Saddle, Spiral Etc Complete. B Control Wiring For Metering Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral Etc Complete. C Panel Accessories Such As Hardware, Gasket, Insulator, Backlite, Panel Knob, Panel Lock, Push Button With Indicators, Heavy Duty Connectors Earthing Arrangement, Etc Complete For Following Feeders I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A D Dismantling, Disconnecting Connections Of All Cables, Shifting Old Panel In Godown Etc Complete Of Following Capacity. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A E Installation Of Panel At Desired Place Including Loading Unloading And Transportation Of Following Capacity I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A F Making New Terminations Of Main Incoming / Outgoing Cables, Etc Complete For Following Feeders. I Up To 100A Ii 100A To 250A Iii 250A To 400A Iv 400A To 800A G Interlocking, Forward / Reverse, Timing And Control Circuit / Star Delta Circuit Etc Control Wiring Using Copper Wire, Ferrule, Lugs, Tie Saddle, Spiral, Etc Complete For One Feeder. 174 Supplying Pedestal Fan 230 Volts 50 Cycles Oscillating Type Complete With Guard Complete A 400 Mm B 450 Mm C 600 Mm 175 Dismantalling Temporary Hangging Wires Accessories, Etc Complete. 176 P / F 3 Phase Heavy Duty Industrial Socket. 177 P / F 1 Phase Heavy Duty Industrial Socket. 178 Tracing Out Faults And Attending Various Breakdown A Tracing Out Fault And Attending Minor Breakdown In Wiring / Electrification Etc Complete B Tracing Out Fault And Attending Major Breakdown In Wiring / Electrification Etc Complete C Tracing Out Fault In Lt Cable / Cable Kit / Panel Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. D Tracing Out Fault In Ht Cable / Cable Kit / Cubical, Removing The Connection Of Cable, Taking Insulation Test. After Fixing New Cable / Cable Kit, Making Termination Of The Cable Again Taking Insulation Test And Giving Satisfactory Test And Trials, Etc Complete. E Attendance, Checking And Assistance For Total Electrical System During General Body Meeting. 179 Providing And Spreading Stone Metal 25Mm Size For 100Mm Depth Above The Ground Level. 180 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, With Operator For All Shifts Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 181 Hiring Charges For Supplying And Maintaining 230V, 50 Cycles Ac Generating Set With Its Accessories And Without Fuel, Without Manpower Complete With Continuous Running On Load / No Load As Per Requirements Complete With Self Certification A 25 To 30 Kva Capacity B 40 To 62.5 Kva Capacity C 125 Kva Capacity D 200 To 250 Kva Capacity E 400 Kva Capacity 182 P / F L.T. Current Transformer Of Suitable Ratio 183 Supplying And Erecting Mini Feeder Pillar Triple Pole With 200A Mccb As Incomer And 2 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500 V 200 A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 184 Supplying And Erecting Mini Feeder Pillar Triple Pole With 300A Mccb As Incomer And 3 Outgoing Circuits With Hrc Fuse Base And Cartridge Of 100A Consists Of Aluminium Bus Bar 500V 300A Complete Erected In 14 Gauge Crca Sheet Box With Supporting Angles, Self-Locks, Gasket And Slanting Top To Be Erected On Provided Foundation 185 P / F Flood Light Led Fitting A 30-40W B 50W C 70 To 80W D 90 To 100W E 120W F 150W G 200W 186 P / F Street Light Led Fitting A 70 To 75W B 75 To 90 W C 100 W 187 Supplying And Erecting Street Light Wall Bracket Made From 40Mm. Dia ‘B’ Class G.I. Pipe Complete . 188 Supplying, Erecting, Testing And Commissioning Self Contained Water Cooler 230 / 250V 50 Cycles Nominal Cooling Capacity Of 40 Litres / Hr And Storage Capacity 80 Litres With Partially Stainless Steel Body Complete.. 189 Providing Multimeter Of Range 0-10-30- 100-1000 Amps And 0-300-600 Volts, Continuity Tester, Ac, Dc Voltage Tester. . 190 Providing Insulator Tester ( Megger ) Cranking Type Having Metal Body Of Range 100 Volts 1000 Ohms . 191 Providing Tong Tester ( Clip On Meter ) Of Range 0-10-30-100-1000 Amps And 0-300- 600 Volts . 192 Providing Non Contact Voltage Detector Of Range 0-600 Volts . 193 Screw Driver With Green Neon Bulb Line Tester 3.6 X 60 Mm . 194 Providing And Fixing Triple Pole And Neutral Surface / Flush Mounted Distribution Board ( Tpndb ) A Distribution Board 12 Way ( 5-4-4 ) B Distribution Board 24 Way ( 5-4-5 ) C Distribution Board 36 Way ( 5-4-6 ) D Distribution Board With Door 12 Way ( 5-4- 10 ) E Distribution Board With Door 24 Way ( 5-4- 11 ) F Distribution Board With Door 36 Way ( 5-4- 12 ) G Distribution Board ( Spndb ) One Way ( 5-4- 13 ) H Distribution Board 4 Way ( 5-4-14 ) I Distribution Board 8 Way ( 5-4-15 ) J Distribution Board With Door 4 Way ( 5-4- 17 ) K Distribution Board With Door 8 Way ( 5-4- 18 ) 195 Reconditioning, Shifting And Installation Of Transformer. A Inspection Of Distribution Transformer On Hv And Lv Side B Dismantling The Distribution Transformer Of From The Plinth / Foundation C Providing And Filling Transformer Oil D Painting Of Transformer Using Smoke Gray Paint Complete . E Providing And Rewinding Of Copper Material For Ht Coils F Heating Of Core And Winding, Including Removing Of Moisture Etc Complete G Providing Oil Arresting Sheet For Low Tension Side Of R Y B Studs, 5Mm Thick Properly Fitted In The Studs Of Transformer. H Providing Oil Arresting Sheet For Top Cover Of Oil Chamber, Lt Connection Box, Oil Tank Etc Parts , 5Mm Thick Properly Fitted In The Top Cover And Nut Bolts Of Transformer I Providing R Y B Stud Bushings Over The Oil Arresting Sheet On The Studs Of Transformer . J Reinsulation By High Quality Uniform Covering Throughout Of 11Kv Windings Using Accessories Complete K Reinsulation By High Quality Uniform Covering Throughout Of 415V Windings Using Accessories Complete L Repairing And Servicing Of Tap Changer Of Transformer M Transformer Oil Filtration N Changing Silica Jel Of Breather And Adding Breather Oil. O Loading, Unloading And Transportation Of Transformer. P Attendance, Engineering Charges For Connection Of Ht / Lt Cables And Giving Satisfactory Test & Trials Of Transformer Complete 196 Providing, Constructing 1.5 Mtr X 1.5 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 197 Providing, Constructing 1.2 Mtr X 1.2 Mtr X 1.5 Mtr + 1 Mtr Underground Transformer Plinth As Per Rate Analysis. 198 Providing And Fixing Rolled Steel Joist ( Girder ) Pole 116X 100 Mm. ( 23 Kg / Meter ) 11Rmt With Provided Base Plate In Provided Foundation As Per Specifications . 199 Making Isolation Circuit Using Ab Switch D.O. Set For Single Pole & Converting The Cutpoint By Dismantling With Nessasary Material, Jumping, Earthing Along With Arrangement Of Shutdown Etc. Complete. 200 Providing C.C. Foundation Including Excavation For The Poles 60 X 60 X 1.5 Mtr Deep In 1:3:6 C.C. ( 45 X 45 X 45 ) Cm Height Plinth Duly Plastered And With Necessary Curing And Finishing In An Appr. Manner . 201 Providing And Fixing G.I. Stay Set For Poles, Including Loop Insulators At Inaccessible Height Complete 202 Providing And Fixing Ht Stay Wire 203 Providing And Fixing Approved Make, 11 Kv Lightening Arrestor With Necessory Accessories Etc Complete 204 Providing And Fixing Tension Porcelain Disc Type Insulator Suitable For 11 Kv Line Complete Erected With Suitable Hardware On Provided Cross Arms As Per Is. 205 Providing And Fixing Procelain Pin Type Insulator Suitable For 11 Kv Line, Complete Erected With Suitable Hardware On Provided Cross Arms. 206 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.09 Mm ( Raccon ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 318 Kg / Km 207 Providing And Fixing A.C.S.R. Conductor Of Size - 6 / 1-4.72 Mm ( Dog ) Complete Erected For Overhead Line With Striging Binding With Proper Size Of Alluminium Conductor For Binding And Suitable Size Of P.G. Clamps For Jumpering Etc. Complete 394 Kg / Km 208 Providing And Fixing Air Break Switch Without Earth Switch 11Kv Outdoor Type Gang Operated Air Break, Triple Pole, 400A Switch Complete 209 Providing And Fixing Approved Make, 11 Kv Out Door Type Drop Out Fuse With Insulator Complete With Fuse Holders, Fuse Barrel With Metal Fitting, Fuse Element Mounted On M.S. Chanel With Working Curent Of 50 Amps Capacity Complete Erected On Provided Cross Arm. 210 Providing And Fixing Extra Thick Alkathene Pipe 10Mm Dia Erected To Enclose Bare Conductor Wires 211 Providing And Fixing Sundries Such As Earthing Powder, Danger Board Etc Accessories. 212 Providing M15 Grade Pcc Works For Plinth As Per Rate Analysis. 213 Designing, Providing, Fabricating, Installing Testing, Commissioning And Giving Satisfactory Tests Of Cubical Industrial Outdoor Type 2000A Lt Acb Changeover Panel As Per Detail Specifications, Making New Terminations Of Main Incoming And Outgoing Cables By Using Lugs Glands Etc Complete. 214 Repairing, Servicing Of 100Kva Dg Set A Providing And Filling Engine Oil 15W40 B Providing And Fixing Lub Oil Filter C Providing And Fixing Fuel Filter D Providing And Fixing Air Cleaner Inner E Providing And Fixing Air Cleaner Outer F Providing And Fixing V-Belt Set G Providing And Filling Radiator Coolant H Providing And Filling Radiator Cleaner 1Ltr Can I Dismantling Of Cylinder Heads, Turbo Charger, Refitting New Gasket, Checking All Allignments And Operation, Reffiting Assembly Again, Giving Test And Trial Complete. J Providing And Fixing Hose Pipe Set K Providing And Fixing Hose Clip Set L Providing And Fixing Fuel Pipe Set M Providing And Fixing O-Ring Set N Diesel Tank Cleaning O Servicing And Callibration Of Fip P Callibration Of Injector And Pressure Testing Q Servicing Of Charging Alternator R Servicing Of Starter Motor S Servicing Cleaning And Warnishing Of Main Alternator T Servicing, Overhaulling, Testing Of Avr, Epu Card, Relay Card, Etc Control Systems U Servicing And Overhaulling Of Turbo ( Dcarbonisation ) V Tappet Setting W Cleaning, Servicing Of Radiator And Refilling Coolant. 215 Repairing, Servicing Of Synchronization Panel By Updating Logic Software, Servicing Of Electronic Controller, Control Relays Terminations, Power And Control Wiring. Also Tightening Of Connections And Cleaning Of Panel Complete. 216 Servicing And Overhauling Of Ht Substation. A Servicing And Overhauling Of 4 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. B Servicing And Overhauling Of 2 Pole Ht Substation By Servicing Air Break Switch By Polishing Contacts, Applying Jelly To Contacts, Alignment Of Ab Switch, Servicing And Overhauling Of D.O. Set By Polishing Hansa And Punja, Applying Jelly To All Hansa And Punja, Changing Fuse Link Tightening Of Connections, Changing Hardware, Changing Acsr Jumper Links By Properly Lugging And Binding Using Alkathene Pipe. Ht Taping Of Connections, Checking Of Insulators, Insulation Test Of Total Installation And Earth Test Of Earthing Pits. 217 Servicing And Overhauling Of Transformer. Servicing And Overhauling Of Transformer By Changing R Y B Stud Bushing Of Ht, Lt Side, Oil Sheet For Low Tension Side Of Y B Studs, Top Cover Of Oil Chamber. Servicing Of Tap Changer, Taping Connections, Testing Of Oil Samples And Taking Insulation Test Of Transformer. Carrying Out Short Circuit, Open Circuit Test And Resistance Test Of Transformer. Changing Silica Jel Of Breather. Transportation, Attendance, Making Connection Of Ht And Lt Side As Well Giving Satisfactory Test And Trials Transformer. 218 Servicing Of Oltc By Checking Operating Mechanism, Alignment, Applying Jelly Various Parts, Checking Of Control Panel Operations And Replacement Of Provided Indicators, Switches, Control Fuses, Hardware, Insulator, Gasket, Polishing Contacts, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Termination Of Incoming Outgoing Cables Required. Cleaning Of Panel, Tightening All Connections Etc Complete. 219 Servicing And Overhauling Of Amf Panel. Servicing Of Contactor, Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Indicators, Push Buttons And Material Procured From Material List Like Voltmeter, Ammeter, Selector Switches, Termination Incoming Outgoing Cables As Required. Also Tightening Of Connections And Cleaning Of Panel Complete. A Up To 200A B 200A To 400A 220 Servicing And Overhauling Of Distribution Panels. Servicing , Repairing Of Distribution Panels By Checking Terminations, Power And Control Wiring Using Appropriate Wire, Lugs, Tie, Saddle, Ferrules, Bus Bars, Changing Hardware Insulator, Gasket, Provided Indicators, Voltmeter, Ammeter, Selector Switches Termination Of Incoming Outgoing Cables As Required. Cleaning Of Panel, Tightening Of All Connections Of Feeders Following Capacity. A Up To 32A B 32A To 63A C 63A To 100A D 100A To 150A E 150A To 200A F 200A To 250A G 250A To 400A H 400A To 630A I 630A To 800A J 800A To 1000A K 1000A To 1250A L 1250A To 1600A
Contract Date: May 25, 2026 Contract Value : 23.96 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
17.
Power #11131078 Price Bid
Tender for Carriage Of Departmental Materials From Electricity Store Centre At Hapur / J.E. Store To The Site Of Work, Including Loading And Unloading At Both Ends. The Work Shall Be Executed Over Kachha And Pakka Roads As Per The Directions Of The Site In-Charge. The Scope Includes Arrangement Of Suitable Transport, Labour For Loading/Unloading, And All Necessary Tools & Plants (T&P). The Lead Distance Shall Be Up To 0-50 Km, Covering Stores Located At Hapur / Ghaziabad / Bulandshahr. , Stay Wire 7/10 Swg , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , 11 Kv completion Poly. Disc Insulator 45 Kn , Stay Set 16X1800 , M.S. Angle 65X65x6 Mm , Acsr Dog Conductor , A.B.Cab. L.T. (3X120)+ (1X95)+(1X16) Sq.Mm , Earth Rod 2540X20 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , 11 Kv Composite Polymer Pin Insulator , D.O Fuse Set 11 Kv , Acsr Weasel Conductor , Ms Channel 100X50 Mm , 11 Kv Tpmo , Lt Abc 3X50+1X35+1X16 Sq.Mm , G.I. Wire 6 Swg , Disc Fitting 45 Kn (T&C) , Gi Wire 4Mm/ 8 Swg , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable H.T. Xlpe 3X120 Sq.Mm , 11 Kv H.T.Xlpe Cable 3X185sq.Mm , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection And Fixing Of The Following Materials As Per Relevant Respo/Departmental Norms And Specifications, Including Proper Installation, Alignment, Tightening, And Commissioning At Site. The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Stay Wire 7/10 Swg , 11 Kv completion Poly. Disc Insulator 45 Kn , M.S. Angle 65X65x6 Mm , 11 Kv V-Type Steel Cross Arm 65X65x6 Mm , Ms Channel 100X50 Mm , 11 Kv Composite Polymer Pin Insulator , Lt Abc 3X50+1X35+1X16 Sq.Mm , Disc Fitting 45 Kn (T&C) , Abc (3X95+1X70+1X16)Sq.Mm , 11 Kv G.I. X-Arm Angle 65X65x6 Mm V-Type , 11 Kv Cable Box O/D 3X120 Xlpe , 11 Kv Cable Box O/D 3X185sq.Mm , Aluminium Cable 1X240 , 11 Kv Cable Box I/D 3X185sq.Mm , 11 Kv Tvm Category C , 11 Kv Ct/Pt Ctr 10/5Amp , 11 Kv Met. Cub. Pilfer Proof Ctr 10/5Amp , Erection Of 11 Mtr Double Pole Structure For 11 Kv Line Including Excavation Of Suitable Size Pits, Fabrication And Fixing Of M.S. Top & Dropper Channel, M.S. T/F Angle, E-Bracket, 11 Kv Pin Insulators With Pins, Disc Insulators With Complete Fittings, Etc., Strictly As Per Respo Drawings/Standard Norms; Providing And Fixing Of All Necessary Clamps Made Of M.S. Flat 50×6 Mm With Suitable Nuts & Bolts, Stone Pad, Jumpering, Alignment, Tightening And All Allied Works; The Scope Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration, Along With Responsibility Of The Contractor For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Directions Of Engineer-In-Charge , Erection And Fixing Of Single Pole Structure For Lt Line Including Excavation Of Suitable Size Pits, Providing And Fixing Of Shackle Insulators, And Complete Installation Of All Requisite Accessories Strictly As Per Respo Drawings/Standard Norms; Including Providing And Fixing Of Holding Clamps Made Of M.S. Flat Of Size 35×5 Mm With Suitable Nuts & Bolts, Stone Pad, Alignment, Tightening And All Allied Works; The Scope Of Work Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, Formation Of Pits, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining All Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Grouting Of St/Pcc Supports In cement concrete 1:3:6 (Cement, Sand & 40 Mm Brick Ballast) In Block Size 450×450 Mm Up To 1/6Th Depth Of Full Length Of Support Below Ground Level And 300 Mm Above Ground Level (Plinth), Using cement concrete 1:3:6 (Cement, Coarse Sand And Stone Grit) Including Mufting As Per Approved Drawing; The Work Shall Include Excavation, Backfilling, Proper Ramming, And Curing Complete In All Respects With All Required Materials; The Scope Further Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Drilling/Excavation, Safety Arrangements, Protection Of Existing Utilities, And Complete Site Restoration; The Contractor Shall Also Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Executing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Plain Cement Concrete Pole 8.5 Mtr , Plain Cement Concrete Pole 11 Mtr , Safe Dismantling, Loading, Transportation, Unloading, Re-Erection, Testing And Commissioning Of 25/63/100 Kva Distribution Transformers Of 11/0.4 Kv Rating, Including Complete Shifting From Existing Location To New Site As Per Departmental Instructions; The Scope Of Work Shall Include Disconnection Of Ht/Lt Lines, Removal And Refixing Of All Associated Technical Accessories Such As Go Switch Set, Drop Out Fuses, Lightning Arrestors, Ht/Lt Bushings, Earthing Arrangements, Breather, Conservator Connections, Oil Level Indicators, Silica Gel, Protection Devices And All Allied Fittings; Proper Handling Using Suitable Capacity Crane/Chain Pulley Block, Providing Required T&P, Skilled Labour, Safety Measures To Avoid Any Mechanical/Electrical Damage, Checking Of Transformer Oil Level And Filtration If Required, Tightening Of All Connections, Re-Alignment, Replacement Of Minor Damaged Components, And Ensuring Proper Earthing And Guarding; Including Carriage Of Transformer And Accessories On Suitable Vehicle Over All Types Of Roads, Complete Installation On Plinth/Structure, Connection With Existing Network, Testing Of Ir Value, Ratio Test And Trial Run For Satisfactory Operation, Strictly As Per Relevant Standards And Direction Of Engineer-In-Charge; The Rate Shall Be Inclusive Of All Labour, Tools & Plants, Transportation, Insurance, Loading-Unloading, And Incidental Charges Required To Complete The Work In All Respects. , 25 Kva Transformer On Double Pole , 63 Kva Transformer On Double Pole , 100 Kva Transformer On Double Pole , Complete Earthing System For 25 Kva, 63 Kva And 100 Kva Distribution Transformers, Comprising Of Supply And Installation Of Suitable Size G.I./Copper Earth Electrodes (Pipe/Rod Type Of Standard Length) Driven Or Installed In Earth Pit Of Required Dimensions, Including Excavation And Backfilling With Layers Of Charcoal/Coke And Common Salt, Watering Arrangement With G.I. Pipe And Funnel With Wire Mesh, And Construction Of Brick Masonry Chamber With Ci/Rcc Cover; Providing And Laying Of G.I. Strip/Wire Of Required Size From Transformer Body, Neutral And Lightning Arrester (If Applicable) To Earth Electrode, Including All Connections With Nuts, Bolts, Washers, Lugs And Proper Clamping, Testing Of Earth Resistance And Ensuring Value Within Permissible Limits As Per Relevant Standards; The Scope Includes All Materials Such As G.I. Pipe/Rod, G.I. Strip/Wire, Charcoal, Salt, Bricks, Cement, Sand, Ci/Rcc Cover, Etc., And All Labour, Excavation, Refilling, Watering, Transportation, Handling, Testing, And All Tools & Plants (T&P) Required For Complete And Satisfactory Installation As Per Respo/Standard Specifications And Direction Of Engineer-In-Charge. , Erection And Fixing Of 11 Kv D.O. Fuse Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Fuse Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Erection And Fixing Of 11 Kv Tpmo Set On St/Pcc Pole Including Mounting/Fixing Materials, Clamps, Nuts & Bolts, And Accessories Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Tpmo Set Shall Be Supplied By The Department; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Provided By Contractor As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Overhead 11 Kv Ht Xlpe Cable (3×120 Sq.Mm) On St/Pcc Poles, Including Proper Hanging And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements, And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site, And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying And Stringing Of Lt Aerial Bunched Cable (Abc) (3×120 + 1×95 + 1×16 Sq.Mm) On St/Pcc Poles, Including Proper Hanging, Dressing And Fixing Of Cable With Necessary Clamps, Supports, Nuts & Bolts (To Be Arranged By The Contractor), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Lifting, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Laying Of 140 Mm Dia (O/D) Pn-4, Pe-80 Grade, Uv Stabilized Hdpe Pipe In Standard Lengths (6 M Each) By Trenchless/Drilling Method For Laying Of Underground 11 Kv Cable, Complete In All Respects As Per Relevant Is Specifications And Directions Of The Site In-Charge; The Scope Of Work Includes Formation Of Entry And Exit Pits, Drilling With Suitable Machinery And Drilling Fluid, Alignment, Jointing, Insertion Of Pipe, Protection Of Existing Utilities, And Complete Site Restoration; The Work Also Includes Cost Of All Labour, Tools & Plants (T&P), Machinery, Materials, Safety Arrangements And All Allied Works Required For Proper Execution; The Contractor Shall Be Responsible For Obtaining Necessary Permissions, Resolving Right Of Way (Row) Issues, And Completing The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying Of 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm Underground Through Hdpe Pipe, Including Pulling, Proper Dressing And Positioning Of Cable, Leaving Adequate Spare Cable In Loop Shape At Both Ends As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Cable Pulling Equipment, Alignment, Safety Arrangements And All Allied Works Will Be Provided By Contractor; Measurement Shall Be Made On Actual Length Of Cable Laid At Site And Payment Shall Be Made Accordingly As Per Departmental Standards And Directions Of The Engineer-In-Charge. , 11 Kv Ht Xlpe Cable Of Size 3×185 Sq.Mm , 11 Kv Ht Xlpe Cable Of Size 3×120 Sq.Mm , Fabrication Of Guarding Angle Other Requisites Material For Guarding By Drawing 02Nos G.I Wire And Making Loop At Suitable Distance As Per Respo Drawing/Norms By Providing Holding Clamps, 02Nos. Eye Bolts Made Of M.S. Round Size 12Mm Dia-100Mm Long & Cross Arm Clamps Made Of M.S. Flat Of Size 50X6mm And Bolts As Per Norms Of Respo Norms, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. As Per Direction Of Site Incharge. (Only Guarding Angle & Gi Wire Will Be Provided By Department). , G.I. Wire 6 Swg , G.I. Wire 4Mm/ 8 Swg , Grouting & Fixing Of Stay Rods (16X1800)Mm Including All Work Of Excavation, Cement Concrete In Size (0.60X0.60X0.30)M In Ratio 1:4:8 Cement, Sand, 40Mm Brick Ballast As Per Drg. Including Back Filling, Proper Ramming Etc And Fixing Tightening & Nozzling Of Stay Wire With Stay Rod With The Poles Of Required Tension As Per Drawing As Per Respo Drawing/Norms By Providing All Grouting Material And Stay Clamp Made Of M.S. Flat Of Size 50X6mm With Proper Size Bolts & Nuts & Loops, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Earthing Of Supports With Ms Earth Rod Of (20X2540)Mm Long Including Excavation Of Pit And Driving M.S. Rod 3.0 M Apart From Support And 0.5M Below The Ground Level And Connection Below The Earth Electrodes With The Help Of G.I. Wire & Earthing Lugs As Per Respo Drawing/Norms Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. Only Earth Rod And Gi Wire Will Be Provided By Department. , Providing & Fixing Of G.I. Pipe 6Dia Class-B Over 11Kv/33 Kv Xlpe Cable Before Mounting The Cable At Double Pole. The Work Includes Fitting Of Clamps, Sealing Of Top And Bottom Of Pipe And One End Of Pipe Is To Be Burried Under Earth About 500Mm Earch Including Mounting And Clamping The Cable On Double Pole Structure And Making Connection With Overhead Line At Both Ends, Includes All Labour, Tools & Plants (T&P), Fabrication, Fitting, Alignment, Tightening, Safety Arrangements And All Allied Works Will Be Provided By Contractor, As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Insulation Piercing Connector (Ipc) Complete In All Respects, Including Proper Installation, Tightening And Ensuring Safe And Reliable Connection, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of All Types Of Clamps Including F-Type Clamps, Holding Clamps, Cross-Arm Clamps, Lt Clamps, Etc., Along With Suitable Nuts & Bolts, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Alignment, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , F-Clamp , Holding Clamp With Nut Bolt , Dead & Clamp , Lt Clamp , X Arm Holding Clamp , Providing And Fixing Of Nut & Bolts As Per Respo/Norms And As Per Direction Of Site Incharge. , Providing And Fixing Of Lt Insulators Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Box Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Lt Fuse Set Complete In All Respects, Including Proper Mounting, Connection, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of Eye Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Fixing Of J Hook Complete In All Respects, Including Proper Mounting, Alignment And Tightening With All Required Accessories, Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Weasel Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Laying, Stringing And Final Sagging Of Acsr Dog Conductor Complete In All Respects, Including Proper Tensioning, Alignment And Dressing Of Conductor Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Use Of Stringing Equipment, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing And Installation Of Maintenance-Free, Multifaceted, Corrosion-Resistant Chemical Earthing Electrode Of Size 80 Mm Dia × 3000 Mm Length, Complete With 50 Kg Backfill Compound And All Required Accessories For Body/Neutral Earthing Of Transformers, Including Providing And Fixing Of M.S. Earth Strip For Connection (The Strip To Be Properly Welded To The Earthing Electrode And Neutral Support), Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Excavation, Installation, Welding, Connection, Testing, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Jumpering Of Lt/Ht Lines For Proper Energization, Including Cutting, Dressing, Binding And Fixing Of Jumpers With Suitable Connectors/Clamps, Ensuring Proper Electrical Continuity And Safety, Complete In All Respects Strictly As Per Respo Drawings/Standard Norms And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Installation, Tightening, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge. , Providing Services For Cutting/Trimming Of Trees And Branches Interfering With Lt/Ht Electrical Lines, Including Clearance Of Vegetation For Safe Operation And Maintenance Of Lines, Complete In All Respects As Per Departmental Standards And Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Machinery, Safety Arrangements, Cutting, Stacking And Disposal Of Cut Material, Protection Of Existing Utilities, Obtaining Necessary Permissions From Concerned Authorities, And All Allied Works Required For Proper Completion Of The Work As Per Directions Of The Engineer-In-Charge. , Safe Dismantling Of Existing/Old Electrical Materials At Site, Including Careful Removal Without Damage To Reusable Items, And Carriage Of Dismantled Materials From Site Of Work To Electricity Store Centre, Hapur, With Loading And Unloading At Both Ends Over Kachha And Pakka Roads, Strictly As Per Directions Of The Site In-Charge; The Scope Of Work Includes All Labour, Tools & Plants (T&P), Handling, Transportation, Safety Arrangements And All Allied Works Necessary For Proper Completion Of The Work As Per Departmental Standards And Directions Of The Engineer-In-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Uttar Pradesh View Result →
18.
Communications and Information Technology  #11109626 AOC
Tender For Ec Com Purulia It Park Civil Maintenance 2025 26 49- 1 Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturers specification and as per direction of the EIC. (At all Floor) One Coat Water based interior grade Acrylic Primer 2 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Standard Quality, 1 coat 3 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : Standard Quality, 2 coats 4 Taking out vitrified tiles carefully by chiselling from walls or floor including stacking serviceable material as directed. 5 Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturers specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor. With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment. 6 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (but including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP), 4mm thick (0.50mm Al.+3.0mm LDPE +0.50mm Al. PVDF coating) 7 Refixing existing ACP wall cladding with Al/MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials including the cost of silicon sealant , labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP At all floors and all locations 8 Supply and applying Weather Silicone sealant of approved make and brand for fixing of grove line between the Glasses as per direction of Engineer-in-charge for Structural Glazing/Curtain wall including complete removal of old cracked sealant and fixing foam. Proper masking tape to be used to achieve clear line. Weather Silicone sealant for filling the Grove line between Glasses or any other material for facial work including labour, scaffolding/ hanging arragement and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge 9 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps. 900 mm long 10 Rewashering stop cock/ bib cock/ push cock/ pillar cock including gland, 15 mm 11 Supplying, fitting and fixing alloy iron with brass spindle bib cock/ stop cock of approved brand and make, spray painted and tested to 21 kg per sq. cm. 15 mm 12 Supplying, fitting and fixing pillar cock of approved make. CP Pillar Cock Super Deluxe with Aerator - 15 mm. (Equivalent to Code No. 508 & Model No. Tropical / Sumthing Special of ESSCO or similar brand). 13 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. E.W.C. Plastic (hallow type) white 14 Supplying, fitting and fixing low-down cistern parts Knob 15 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc., with S trap 16 Removing old scales, blisters etc. of interior surface of walls,ceiling by scraping etc. and preparing smooth and even surface with rendering or cement mortar (1:2) (as necessary), to make the surface suitable for receiving distemper. (Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge). 17 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] With 1:4 cement mortar, 15 mm thick 18 Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) 19 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987; coloured, toughened glass conforming to IS: 2553-1992 (part-II), 6 mm thick 20 Labour charge for fabrication and installation of structural Glazing/Curtain Wall made from annodized extruded alloy aluminium sections for the following units:- Structural Glazing made of extruded and annodized alloy aluminium sections, fabrications including cutting to proper shape and size, drilling including cost of brackets, fastener bolt, mullion bolt, nuts & washers, maskin tape, double side adhesieve crosslink foam (used for guard of glazed silicon on sub-frame), tissue paper foam (used as filler between sub-frame and under backing of weather silicon), screws and other necessary hardwares, fixing of glass as per drawing, specification and direction of Engineer-in-Charge. (The rate includes hire charges of all tools and plants, including all incidental charges, adhesieve, joiners such as screw,cleate angle,etc. but excluded the cost of extruded aluminium sections, glass, glazed silicon, weather silicon etc.) 21 Supplying fitting and fixing door frame with M.S. angle as per drawing & direction of required section.The holes for counter sunk machine screw & nuts will be such as to fit 8 to 10 mm Iron screw. The counter sunk nut to be welded . (including taking out of old wooden door frame and mending good the damages) The nuts are to be welded after careful checking with screw.All welding spots should be properly filed or rounded smooth including cost of welding hinges for hinge cleats , lugs for hasp bolt, socket bolt etc. and necessary M.S. clamps of 25mm x 6mm flat 225mm long as per direction welded to the frame fitted andfixed in position excluding cost of concrete. 22 M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. at all floors 23 Supplying, Fitting & Fixing Factory made P.V.C. door frame of size 50 mmx47 mm with a wall thickness of 5 mm, made out of extruded 5 mm, PVC sheet miter cut at two corners and joined with two nos of 1.5 mm long brackets of 15 mm x15 mm M.S. square tube. The two vertical door profiles are to be reinforced with 19 mmx 19 mm M.S. Square tube of 19 gauge, weather seal to be provided through out the frame. The door frame shall be fixed with the wall using 65/100 mm long M.S. Screws through the frame by using P.V.C fasteners. A minimum of 4 Nos of screws to be provided for each vertical member and minimum 2 Nos for horizontal member etc. complete as per Manufacturer‟s specification and direction of Engineer-in-Charge. 24 Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5 mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail. Paneling of 5 mm th. both side PVC sheet to be fitted in the M.S. frame welded/sealed to the styles & rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the “C” channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in-Charge. In ground floor. 25 Removing old paint from blistered painted surface with application of soda, sajimati or any approved chemical paint remover and exposing the original surface including cleaning and thorough washing to remove all traces of the removing agent including taking out shutters and refixing the same where necessary 26 Painting with ready mixed red lead paint of approved make and brand, Two coats 27 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary On steel or other metal surface : With other than hi-gloss of approved quality Two coats (with any shade except white) 28 Providing and fixing exterior quality Aluminium Composite Panel (ACP) wall cladding on existing Al. /MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials (including the cost of silicon sealant), labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP), at all floors and all locations 3mm thick (0.25mm Al.+2.5mm LDPE +0.25mm Al. PVDF coating) 29 Refixing existing ACP wall cladding with Al/MS frame work with GI brackets, ACP fixed on the existing frame work by folding the edges of ACP panel (Engraving the rear surface of ACP sheet) with CP angles, cleats and strainless Steel screws forming groves at the periphery of ACP panel. Such grooves filled with foam and silicon sealant etc. complete with all materials including the cost of silicon sealant , labour, scaffolding and all other incidental charges complete in all respect as per specification and direction of Engineer-in-charge. (Mode of payment is on finished surface area of ACP At all floors and all locations
Contract Date: May 18, 2026 Contract Value : 4.36 Lakh
Government Departments No of Bidders 6
West Bengal View Result →
19.
Housing Urban and Rular Development #11097527 Technical Bid
Tender for Item Rate Boq Boq_Ver3.0 Item Rate Normal Inr Only Inr Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: Executive Engineer, Mechanical & Hospital Division Gmch Jammu. Replacement Of Existing Damaged Ms Tank By Way Of Installation Of Make-Up Water Storage Tanks With Ms Platform , Cross Bracing ,Ms Ladder And Pipeline System Of Chiller Plant Of Capacity 225Trx03 Nos. At Government Super Specaility Hospital Jammu. Mhdj/E-Nit 09 Of 2026-27 Dated: 20.04.2026 Due : 29.04.2026 Bidder Name : Price Schedule (This Boq Template Must Not Be Modified/Replaced By The Bidder And The Same Should Be Uploaded After Filling The Relevent Columns, Else The Bidder Is Liable To Be Rejected For This Tender. Bidders Are Allowed To Enter The Bidder Name And Values Only ) Number # Text # Text # Number # Text # Number Number Text Text # Number # Text# Text # Number # Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number Number Text Text Number Number Number # Number # Text Text Number # Number # Date Number # Number # Text # Sl. No. Item Code / Make Quantity Units Estimated Rate Addition / Deduction Rate Including Gst To Be Quoted By The Bidder Rs. P Currency Convertion Against Each Item Quoted Currency In Inr / Other Currency Rebate On Old Parts In Percentage (%) If Any Excise Duty Vat Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 Iiird Party I.E Dgs&D / Rites Etc Inspection Charges @0.34%+Service Tax Less For Cenvat Credit,If Any Respect Of Supplies Under Full Excise Duty Category Net Cost Of Item Rs. P Total Amount Total Amount With Taxes Total Amount In Words , Fabrication And Installation Of A Structural Platform For Placement Of Two Numbers Water Storage Tanks Of 2000 Litres Capacity Each . The Platform Shall Be Designed To Safely Support The Load Of Two Fully Filled Tanks Along With The Self-Weight Of The Structure. The Overall Platform Size Shall Be Approximately 3000 Mm × 1600 Mm X 1000 Mm To Accommodate Two Tanks Placed Side By Side With Adequate Clearance For Safe Operation And Maintenance.The Supporting Structure Shall Be Fabricated Using 80 Mm Dia Heavy C-Class Ms Pipes (Total - 330 Kg For Foundation , Cross Bracing , M S Pipe Stair/Ladder ) .The Foundation Of Tank Include Vertical Columns, Horizontal Beams And Bracing Members To Ensure Adequate Load Bearing Capacity And Structural Stability. The Top Surface Of The Platform Shall Be Provided With 8 Mm Thick Ms Sheet-280 Kg , Properly Cut And Continuously Welded To The Supporting Frame To Provide A Rigid And Uniform Base For Placement Of The Tanks.Each Vertical Column Shall Be Provided With A Ms Base Plate Of Minimum Size 200 Mm × 200 Mm × 10 Mm Thick-15 Kg , Welded At The Bottom Of The Column For Proper Load Distribution. The Base Plates Shall Be Securely Anchored To The Concrete Foundation Using Suitable Anchor Bolts/Fasteners To Ensure Stability Of The Structure.To Ensure Additional Safety And Rigidity, Ms Pipe Cross Supports Shall Be Provided Above The Platform Level Around The Tanks, Forming A Protective Frame On All Sides. These Cross Members Shall Help Secure The Tanks In Position And Prevent Displacement Due To Heavy Wind Loads Or External Forces.A Ms Stair/Ladder Shall Also Be Fabricated And Fixed With The Structure Up To The Platform Level And Further Extended Above The Platform With A Small Access Step Arrangement, Enabling The Operator To Safely Reach The Top Portion Of The Tanks For Checking Water Level, Inspection And Maintenance. Proper Hand Support/Guard Pipe Shall Be Provided For Safety While Accessing The Tanks.The Platform Shall Be Designed Considering A Minimum Load Of Approximately 4500-5000 Kg (Two Fully Filled Tanks Of 2000 Litres Each Including Structural Weight And Safety Factor). All Ms Members Shall Be Properly Aligned, Cut, Fitted And annual rate contract Welded, And Weld Joints Shall Be Finished Smooth By Grinding. The Entire Ms Structure Including Pipes, Plates And Sheet Shall Be Cleaned And Coated With One Coat Of Anti-Corrosive Red Oxide Primer Followed By Two Coats Of Synthetic Enamel Paint For Protection Against Rust And Weather Exposure.The Complete Job Include Fabrication, Erection, Welding, Anchoring, Painting, Installation Of Stair/Ladder, Overhead Cross Supports And Making The Platform Ready For Placement Of Tanks, Including All Labour, Materials And Allied Works,Transporation , Carriage Cahrges Of Mateial. Complete In All Respects As Per Site Requirements. , Providing Of Water Storage Tanks Of 2000 Litres Capacity Manufactured From 100% Virgin Food-Grade Polyethylene, Suitable For Safe Water Storage. The Tank Shall Be Of Multi-Layer Rotational Moulded Construction With Uv Stabilised Outer Layer To Protect Against Sunlight And Weathering. The Tank Shall Incorporate 4P Protection Technology (Anti-Virus, Anti-Bacteria, Anti-Fungus And Anti-Algae) With Active Silver Antimicrobial Technology To Ensure Hygienic Water Storage. The Tank Body Shall Have Multi-Ribbed Structural Design For Enhanced Rigidity And Durability And Shall Be Provided With A Uv Protected Threaded Lid/Manhole Cover To Prevent Entry Of Dust, Insects And Contamination. The Tank Shall Be Rohs Compliant, Corrosion Resistant And Suitable For Outdoor Installation, Available In Standard Colours The Tanks Shall Be Used For Make-Up Water Supply To The Chiller Plant System, Ensuring Continuous Water Availability For Maintaining The Required Water Level In The Cooling System.The Scope Shall Also Include Loading, Transportation, Unloading And Carriage/Hoisting Of The Tanks Up To The Roof Level Of The Hospital Building ( Fifth Floor) Through Suitable Safe Means Such As Manual Labour, Rope And Pulley Or Lifting Arrangement Without Causing Any Damage To The Tanks Or Building Structure. The Tanks Shall Be Carefully Shifted To The Designated Installation Location And Placed On The Prepared Platform, Complete In All Respects As Per Site Requirements , Installation Of Two Numbers 2000 Litres Capacity Overhead Water Storage Tanks On The Fabricated Platform, Including Making Complete Make-Up Water Supply Arrangement For The Chiller Plant System. The Scope Of Work Shall Include Providing, Laying And Fixing Of 32 Mm Dia Ms Pipeline (Heavy Class) - 50 Metres In Length For The Make-Up Water Line From The Existing Water Source To The Tanks. The Pipeline Shall Be Properly Cut, Threaded, Aligned And Installed With Necessary Pipe Fittings And Accessories Such As Ms/Gi Nipples, Sockets, Bends, Tees, Reducers, Unions, Clamps And Supports As Required For Proper Installation.The Jobl Also Include Providing And Fixing Suitable Isolation Valves, Float Valve Arrangement Inside The Tank For Automatic Control Of Water Level, And Necessary Inlet, Outlet, Overflow And Drain Connections For Proper Operation Of The Tank System. The Pipeline Shall Be Securely Supported With Ms Pipe Supports/Clamps At Suitable Intervals And All Threaded Joints Shall Be Properly Sealed To Ensure Leak-Proof Operation.The Job Also Include Cutting, Modification And Welding Of The Existing Chiller Make-Up Water Pipeline For Providing New Connection From The Newly Installed Tanks, Including Edge Preparation, Alignment, annual rate contract Welding With Suitable Electrodes, Grinding And Finishing Of Weld Joints. After Installation, The Entire Pipeline Shall Be Tested For Leakage And Proper Flow, And All Welded Portions Shall Be Cleaned And Painted With Anti-Corrosive Primer And Suitable Paint.The Job Nclude Complete Installation, Fabrication, Welding, Connection, Testing And Commissioning Of The Entire Make-Up Water System, Including All Labour, Materials, Fittings, Valves, Welding Electrodes, Cutting, Threading, Supports, Clamps And Allied Works, Carriage Of Materials To Roof Level And Making The System Fully Operational, Complete In All Respects As Per Site Conditions Total In Figures 23 23 0.0 23 Inr Zero Only Quoted Rate In Figures Select 0.0 0.0 Zero Only Quoted Rate In Words Inr Zero Only
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
20.
Water Resources and Irrigation #11087445 Technical Bid
Tender for Repair, Operation & Maintenance Of Water Vending Machine 9 Nos Installed In Different Wards Of The Muncipal Carporation Area Of Shimla City , Including Ensuring Uninterupted 24X7 Functionality & Maintenance Of Cleanliness & Hygienic Conditions In And Arround The Water Vending Machine Installations. , The Scope Of Work Shall Include The Followings:- Repair, Servicing & Preventive Maintenance Of Above Water Vending Machines Installed In Various Wards To Keep In Them In Proper Working Condition At All Times. Operation & Maintenance Of The Water Vending Machines On A Round The Clock Basis ( 24X7) To Ensure Uninterrupted Supply Of Potable Drinking Water To The Public. Replacement Of Defective Or Worn-Out Components , Consumables, Filters, Electrical Parts , Wherever Required To Maintain The Operational Efficiency Of The Machine. All Works Shall Be Carried Out As Per The Direction & Satisfaction Of The Engineer-In- Charge , & No Extra Payment Shall Be Admissible For Incidental Works Required For Proper Completion Of The Job. , Detail Of The Parts For 9 Nos Water Vending Machine Of ( 250 Lph ) Capacity , providing and Fixing Of Raw Water Pump Of 1 Hp, Single Phase Of Any Approved / Certified Brand Including Complete Installation , Testing & Commissining With All Necessary Accessories As Per Direction Of Engineer-In-Charge. , providing and Fixing Of Vertical Booster Pump Of 1.5 Hp, Single Phase Of Any Approved Brand Including Mounting , Alignment & Connections Complete As Per Direction Of Engineer-In-Charge. , providing and Fixing Of Ps Big Blue Filter ( Inner ) Suitable For Pre-Filtration , Including Installation Inside Filter Housing. , providing and Fixing Of Ps Big Blue Jumbo Housing Of Size 20 X 4 Suitable For Heavy Duty Filtrationb System Complete With Mounting Clamps And Connection. , providing and Fixing Of Ps Big Blue Carbon Filter( Inner ) Suitable For Chlorine And Organic Compound Removal , For Installation In Big Blue Housing . , providing and Fixing Of Brass Solenold Valve (Sv) 3/4 Imported , Suitable For Ro Applications Including Electrical & Pipe Connections. , Providing & Applying 118 Mm Upvc Solvent For Jointing Of Upvc Pipes And Fittings I/C Cleaning , Surface Prepration, And Application. , Supplying & Fixing Of Ro Membrane Of Size 40X40 Suitable For 2200 Tds , I/C Mounting In Housing , & Connecting For Operation. , Providing & Fixing Of Upvc Union 3/4 Suitable For Ro / Filtration Piping System Including Jointing. , Providing & Fixing Of Upvc Socket 3/4 For Coonction Of Upvc Pipes. , Providing & Fixing Of Upvc Elbow 3/4 For Pipe Bending And Dirctional Changes. , Providing & Fixing Of Reducer 1/2 X 1/3 Suitable For Reducing Pipe Diameter In Ro Line. , Providing & Fixing Of Upvc Solvent For Making Leak- Proof Joints In Piping Network. , Providing & Supplying Of Teflon Tape ( 1 Box) For Sealing Threading Joints And Fittings In Ro/ Plumbing Network. , Providing Laying & Jointing Of Upvc Pipe 1.8 ( One Roll) I/C Necessary Fittings , Cutting & Jointing. , Providing Of Ro System Panel Including Circuit Breakers , Switches, Indicators & Control Wiring For Ro Unit. , Providing & Fixing Dosing Pump With Suction & Discharge Accessories For Chemical Dosing Complete With Connections. , Providing & Fixing Of Pressure Gauge ( Standard ) For Monitoring Ro Inlet/Outlet Pressure. Including Fitting And Calibration. , Providing Cutting , Laying And Jointing Of Upvc Pipe System For One Water Vending Machine Unit, I/C Required Fittings , Support & Solvent Joints. , Providing & Fixing Of Flow Meter , Suitable For Ro System , For Measuring Input/Output Water Flow With Fitting. , Providing & Fixing Of Low Pressure Switch , With Wiring And Control Connection For Automation In Ro System. , Providing & Fixing Of High Pressure Switch , With Necessary Electrical Wiring And Control Setup. , Providing & Fixing Of Float Valve ( Floty ) For Automatic Water Level Control In Storage Tank. , Providing & Fixing Of Filter Key ( Spanner Type ) Suitable For Opening & Closing Big Blue Filter Housing. , Providing & Fixing Of Push Button Switch 1/2 Inch For Manual Pump Operation, Including Mounting Plate And Wiring. , Providing Tool & Fro ( To & Fro) Charges For Service Engineer For Servicing Of Water V Vending Machine I/C All Charges For Visit, Diagnostics, Minor Repair & Machine Reset Complete As Per The Direction Of Engineer-In- Charge. , Deployment Of Skilled Manpower For Operation , Zone Wise Routine Inspection , Cleaning , Preventive Maintenance And Complaint Attending Of Water Vending Machine ( Water Atm) I/C Checking Of Water Quality , Filtration System , Pump, Motor, Electrical Components , Upkeep Of Hygenic Conditions In And Around Installations , Maintance Ofd Prescribed Records , Submission Of Daily/Periodic Compliance Reports To The Engineer-In-Charge / Competent Authority Complete As Per Direction & Satisfaction Of Engineer-In-Charge. , Duties And Responsibilities:- Carrying Out Zone Wise Routine Field Visit To Installed Water Vending Machines ( Water Atm) On A Daily Basis, Strictly In Accordance With The Direction Of Engineer-In-Charge . Attending & Inspecting Minimum 6-7 Water Vending Machines Per Day Under Normal Operating Conditions Where No Complaints Are Reported. Attending 3-4 Water Vending Machines Per Day During Complaint Based Maintenance , I/C Fault Detection , Diagonsis And Rectification. Performing Routine Inspection , Cleaning, Servicing, Preventive Maintenance Of Water Vending Machiness To Ensure Smooth & Uninterrupted Operations. Checking , Testing & Ensuring Proper Functioning Of All Component. Water Quality Parameters And Dispensing Quality. Filtration System And Filter Cartridges. Pump , Motors, Valves , Pipe Lines And Associated Machenical Components. Electrical Panels , Wiring, Control Units And Allied Electrcal System. Attending Complaint-Based Repairs. Troubleshooting Operational And Technical Faults, And Carrying Out Replacement Of Minor Parts/Components.. Wher3ever Required, After Obtaining Approval Of The Engineer-In-Charge. Ensuring Proper Hygience And Cleanliness In And Around The Water V3ending Machine Installations, Including The Dispensing Area And Surroundings. Maintaining Daily Visit Registers, Service Recordes, Complaint Registers, And Maintenance Logs In The Prescribed Formats Approved By The Department. Submitting Routine Visit Compliance Reports And Details Of Complaint Redressal Tgo The Concerned Authority On A Daily/Periodic Basis, As Directed. Coordinating With Supervisory Staff And Departmental Officials To Ensure Timely And Effective Resolution Of Technical And Operational Issues. Ensuring Safe, Hygienic, And Continuous Supply Of Potable Drinking Water To The Public Without Inte4rruption, In Accordance With Departmental Standardds And Statutory Guideline.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Himachal Pradesh View Result →
22.
Housing Urban and Rular Development #11053840 AOC
Tender For Annual Repair Special Repair /Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal- 1 Ar/Sr/Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal 1St Call P.A.C. 40.00 Lakh,As Per Building Sor Wef 01-01-2024 Schedule Attached Complition Period 180 Days Please Enable Macros To View Boq Information Ar/Sr/Mow Works In Various Rb/Nrb Under Section No.7, Jail Sub Division No.1, Bhopal Building Sor Wef 01.01.2024 Probable Amount Of Contract - Rs. 40.00 Lakh S.No Description Qty. Unit Rate Amount 2 2.1 All Kinds Of Soil. 100 Sqm 803.0 3 2.6 All Kinds Of Soil Cum. 147.0 4 2.7 2.7.1 Ordinary Rock Cum. 287.0 2.7.2 Hard Rock (Requiring Blasting) Cum. 519.0 2.7.3 Hard Rock (Blasting Prohibited) Cum. 828.0 5 2.25 2.25.1 All Kinds Of Soil. Cum 30.0 2.25.2 Ordinary Or Hard Rock. Cum 53.0 6 2.27 2.27.1 With Hard Muram Having Cbr >12 % At Under Floors Including Watering, Ramming And Compacting (Minimum Compaction 95% Of Mdd) In Layers Not Exceeding 20Cm In Thickness And Dressing Complete. (Note:- Maximum Thickness Of This Layer To Be Provided Shall Be 30Cm) Cum 393.0 2.27.2 Supplying And Filing In Plinth With Soil (Other Then Bc Soil ) Having Mdd Not Less Than 1.85 T/M3 Under Floors Including Watering, Ramming And Compacting (Minimum Compaction 95% Of Mdd) In Layers Not Exceeding 15Cm Depth And Dressing Complete. Cum 331.0 7 4.1 4.1.1 With 20Mm Nominal Size Graded Stone Aggregate. 4.1.1.1 M-25 – Grade Concrete Cum 6338.0 4.1.1.2 M-20 – Grade Concrete Cum 4933.0 4.1.1.3 M-15 – Grade Concrete Cum 4471.0 4.1.1.4 M-10Nominal (Mix-1 Cement : 3 Sand : 6 Graded Stone Aggregate ) Cum 3890.0 4.1.2 With 40Mm Nominal Size Graded Stone Aggregate. 4.1.2.1 M-15 - Grade Concrete Cum 4403.0 4.1.2.2 M-10 Nominal (Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate) Cum 3808.0 4.1.2.3 M-7.5 Nominal Mix -1 Cement : 4 Sand : 8 Graded Stone Aggregate Cum 3474.0 4.1.3 With Fly Ash. 4.1.3.1 1:2½:4:11 (1 Ordinary Portland Cement : 2½ Fly Ash : 4 Sand : 11 Graded Stone Aggregate 40 Mm Nominal Size) Cum 3459.0 4.1.3.2 1:2½:4:11 (1 Ordinary Portland Cement : 2½ Fly Ash : 4 Sand : 11 Graded Stone Aggregate 40 Mm Nominal Size) Cum 3150.0 Note: No Fly Ash Is To Be Added To Portland Pozzolona Cement In Any Case Which Itself Contains Fly Ash. 8 4.2 4.2.1 With 20Mm Nominal Size Graded Stone Aggregate 4.2.1.1 M-25 – Grade Concrete Cum 6582.0 4.2.1.2 M 20 – Grade Concrete Cum 5177.0 4.2.1.3 M 15 – Grade Concrete Cum 4714.0 4.2.1.4 M-10 Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 4134.0 4.2.2 With 40Mm Nominal Size Graded Stone Aggregate 4.2.2.1 M-15 - Grade Concrete Cum 4647.0 4.2.2.2 M-10 Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 4052.0 9 4.3 4.3.1 Upto Plinth: Foundations, Footings, Bases For Columns, Plinth Beams, Curtain Walls, Columns Below Plinth. Sqm 169.0 4.3.2 Above Plinth: Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Buttresses, And String Courses Fillets Etc. Sqm 267.0 4.3.3 Above Plinth: Columns, Pillars, Posts And Struts. Sqm 356.0 10 4.4 4.4.1 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 4471.0 4.4.2 M-10 (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 3890.0 11 4.6 4.6.1 M-25 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5095.0 4.6.2 M-20 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5558.0 4.6.3 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 5095.0 4.6.4 M-10 (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement: 3 Sand: 6 Graded Stone Aggregate. Cum 4515.0 12 4.7 4.7.1 M-15 (With 20Mm Nominal Size Graded Stone Aggregate) Cum 7057. 00 4.7.2 M-10 (M 10) (With 20Mm Nominal Size Graded Stone Aggregate) Nominal Mix -1 Cement : 3 Sand : 6 Graded Stone Aggregate Cum 6477.0 13 4.15 Note For Item No. 4.15:- The Quantity Will Be Calculated By Multiplying The Depth Measured From The Sub-Soil Water Level Upto Centre Of Gravity Of Concrete Under Sub-Soil Water Level With Quantity Of Concrete In Cum Executed Under Sub-Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1M. 0.05M Or More Shall Be Taken As 0.1M And Less Than 0.05M Ignored. Cum 109.0 14 5.1.1 5.1.2 M-15 Grade Concrete Cum 5397.0 5.2 Reinforced Cement Concrete Work (With 20 Mm Nominal Size Graded Stone Aggregate) In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Posts And Struts Etc. Above Plinth Level And Upto Floor Two Level Excluding Cost Of Centering, Shuttering, Finishing And Reinforcement: 15 5.2.1 5.3 Reinforced Cement Concrete Work (With 20 Mm Nominal Size Graded Stone Aggregate) In Beams, Suspended Floors, Roofs Having Slope Of Any Degree Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Staircases Above Plinth Level And Upto Floor Two Level Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement In Concrete Grade. 16 5.3.1 5.4 Providing And Laying Upto Floor Two Level Reinforced Cement Concrete (With20 Mm Nominal Size Graded Stone Aggregate) In Kerbs, Steps And The Like Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement With Concrete Grade. 5.4.1 M-20 Grade Concrete Cum 5542.0 17 5.9 5.9.1 Foundations, Footings, Bases Of Columns, Etc. For Concrete Upto Plinth Level Sqm 190.6 5.9.2 Walls (Any Thickness) In Cluding Attached Pilasters Butter Esses, Plinth Beams And String Courses Etc. 5.9.2.1 Uptoplinthlevel. Sqm 219.0 5.9.2.2 Above Plinth Upto 3.6 M Height From Plinth Level Sqm 330.0 5.9.2.3 Extra For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De-Shuttering And Decentering At All Levels, Over A Height Of 3.6 M, For Every Additional Height Of 1 Metre Or Part Thereof. Sqm 40.0 5.9.3 Suspended Floors, Roofs, Landings, Balconies And Access Platform. Sqm 439.6 5.9.4 Shelves(Cast In Situ) Sqm 290.0 5.9.5 Lintels, Beams, Girders, Bressumers And Cantilevers Sqm 356.0 5.9.6 Columns, Pillers , Piers, Abutments, Sqm 471.2 Posts And Struts. 5.9.7 Stairs, (Excluding Landings) Except Spiral- Staircases. Sqm 435.7 5.9.8 Spiral Staircases (Including Landing). Sqm 450.0 5.9.9 Arches, Domes,Vaults Upto 6M Span Sqm 1141.6 5.9.10 Extra For Arches, Domes, Vaults Exceeding 6 M Span Sqm 451.3 5.9.11 Chimneys And Shafts Sqm 294.0 5.9.12 Coffer/Waffle Slab Of Any Size Or Shape As Shown In The Drawing. Sqm 1481.0 5.9.13 Well Steining Sqm 264.0 5.9.14 Vertical And Horizontal Fins Individually Or Forming Box Louvers Band, Facias And Eaves Boards. Sqm 643.4 5.9.15 Extra For Shuttering In Circular Work Or Any Other Geometrical Shape (20% Of Respective Centering And Shuttering Items). Sqm 0.2 5.9.16 Small Lintels Not Exceeding 1.5M Clear Span, Mouldingas Incornices, Window, Sills, Courses, Bands, Copings, Bed Plates, Anchor Blocks And The Like. Sqm 191.0 5.9.17 Cornices And Mouldings Sqm 565.0 5.9.18 Small Surfaces Such As Cantilever Ends, Brackets And Ends Of Steps, Caps And Bases To Pilasters And Columns And The Like. Sqm 529.6 5.9.19 Weather Shade, Chajjas, Corbels Etc., Including Edges. Sqm 534.2 5.9.20 Suspended Floors, Roofs, Landings, Balconies And Access Platform. With Water Proof Ply 12 Mm Thick. (Item To Be Executed With Prior Permission Of S.E. In Case Of B & R Works And From Additional Project Director In Case Of Piu Works) Sqm 575.35 5.9.21 Lintels, Beams, Columns, Girders, Bressumers And Cantilevers With Waterproof Ply 12 Mm Thick (Item To Be Executed With Prior Permission Of S.E. In Case Of B&R Works And From Additional Project Director In Case Of Piu Works) Sqm 521.2 18 5.1 5.10.1 Suspended Floors, Roofs, Landing, Beams And Balconies (Plan Area To Be Measured). Sqm 212.0 19 5.12 5.12.1 50 Mm Thick Sqm 790.0 5.12.2 40 Mm Thick Sqm 689.0 5.12.3 25 Mm Thick Sqm 598.0 20 5.16 (Note:- (1). Spacer Bars (Chairs) Shall Be Paid Separately As Shown In The Drawing And As Per Direction Of Engineer In Charge. (2). No Extra Payment Shall Be Done For Overlaps And/Or Couplers. (3). Couplers Shall Be Conforming To Is Code On “Reinforcement Couplers For Mechanical Splices Of Bars For Concrete Reinforcement - Specification”) 5.16.1 Mild Steel And Medium Tensile Steel Bars. Kg 78.0 5.16.2 Hard Drawn Steel Wire Kg 75.0 5.16.3 Cold Twisted Bars (Ctd) Kg 81.0 5.16.4 Hot Rolled Deformed Bars Kg 81.0 5.16.5 Hard Drawn Steel Wire Fabric Kg 76.0 5.16.6 Thermo-Mechanically Treated Bars. (Tmt/Tmx) Fe 500 Or More Conforming To Is 1786 Kg 80.0 21 5.22 5. 22.1 12 Mm Thick Sqm 402.0 5. 22.2 25 Mm Thick Sqm 574.0 5. 22.3 50 Mm Thick Sqm 674.0 22 5.23 5. 23.1 Non-Asbestos Fibre Cement Board 6 Mm Thick As Per Is: 14862. 5. 23.1.1 150Mm Wide. Rm 102.0 5. 23.1.2 200Mm Wide. Rm 137.0 5. 23.1.3 250Mm Wide. Rm 153.0 5. 23.2 Aluminium Fluted Strips 3.15Mm Thick. Rm 483.0 5. 23.2.1 150 Mm Wide. Rm 646.0 5. 23.2.2 200 Mm Wide. Rm 725.0 5. 23.2.3 250 Mm Wide. 5. 23.3 Stainless Steel Grade 304 Plate-1.0 Mm Thick 5. 23.3.1 150 Mm Wide. Rm 367.0 5. 23.3.2 200 Mm Wide. Rm 443.0 5. 23.3.3 250 Mm Wide. Rm 555.0 23 5.25 Note- For Item No. 5.25:-The Quantity Will Be Calculated By Multiplying The Depth Measured From The Subsoil Water Level Up To The Centre Of Gravity Of The R.C.C. Under Ubsoil Water With The Quantity Of R.C.C. In Cubic Metre Executed Under Subsoil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. No Extra Payment Shall Be Made For Placing Reinforcement Or Centering & Shuttering Under Sub – Soil Water Condition 24 5.33 5. 33.1. Frame 125 Mmx 60 Mm (Double Rebate) Rm 366.0 5. 33.2. Frame 100Mmx 60 Mm (Single Rebate) Rm 339.0 5. 33.3 Frame 85Mmx 60 Mm (Single Rebate) Rm 325.0 25 6.1 6.1.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5818.0 6.1.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5626.0 26 6.2 6.2.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 6012.0 6.2.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5821.0 27 6.3 6.3.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5252.0 6.3.2 Cement Mortar 1:6 (1 Cement:6 Sand). Cum 5061.0 28 6.4 6.4.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5446.0 6.4.2 Cement Mortar 1:6 (1 Cement:6 Sand). Cum 5255.0 29 6.5 6.5.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 4347.0 6.5.2 Cement Mortar 1:6 (1 Cement: 6 Sand). Cum 4155.0 30 6.6 6.6.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 4541.0 6.6.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4350.0 31 6.7 6.7.1 Having 100 Kg / Cm2 Average Compressive Strength. 6.7.1.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5384.0 6.7.1.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5162.0 6.7.2 Having 75 Kg / Cm2 Average Compressive Strength. 6.7.2.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5271.0 6.7.2.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 5049.0 6.7.3 Having 50 Kg / Cm2 Average Compressive Strength. 6.7.3.1 Cement Mortar 1:4 (1 Cement : 4 Sand) Cum 5158.0 6.7.3.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4936.0 32 6.11 Providing Half Brick Masonry With Well Burnt Chimney Bricks In Bull Patent Trench Kiln Manufactured By Ghol Process Crushing Strength Not Less Than 40 Kg /Cm2 And Water Absorption Not More Than 15% In Superstructure Above Plinth Level And Up To Floor Two Level. 6.12.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 697.0 6.12.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 673.0 33 6.13 6.13.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 639.0 6.13.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 615.0 34 6.14 6.14.1 Cement Mortar 1:3 (1 Cement : 3 Sand) Sqm 546.0 6.14.2 Cement Mortar 1:4 (1 Cement : 4 Sand) Sqm 522.0 35 6.15 6.15.1 Having 100 Kg/Cm2 Average Compressive Strength. 6.15.1.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 570.0 6.15.1.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 551.0 6.15.2 Having 75 Kg/Cm2 Average Compressive Strength. 6.15.2.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 524.0 6.15.2.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 505.0 6.15.3 Having 50 Kg/Cm2 Average Compressive Strength. 6.15.3.1 Cement Mortar 1 : 3 (1 Cement : 3 Sand) Sqm 479.0 6.15.3.2 Cement Mortar 1 : 4 (1 Cement : 4 Sand) Sqm 459.0 36 6.24 Note: - The Quantity Will Be Calculated By Multiplying The Depth Measured From Sub - Soil Water Level Up To The Centre Of Gravity Of Brick Work Under Sub - Water With The Quantity Of Brick Work In Cum Executed Under The Sub - Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. 37 6.27 6.27.1 Aac Masonry In Polymer Modified Mortar Cum 5052.0 38 6.29 Of Minimum 80 Mmwidth And Depth Equal To Slab/Panel Thickness Running At Center Of Load Bearing Wall/ Beam/ Supports And On Other Support As Well To Achieve Diaphragm Action As Per Is 1893:2000. The Peripheral Bond Beam Shall Have Minimum 2 Bars Of 12 Mm Dia As Longitudinal Bars Which Shall Be Held Down By Hook Made In 12 Mm Dia Vertical Bars Coming Out From Structural Beam. However Concrete In Groove And Bond Beam Shall Not Be Paid Separately But Shall Be Measured With Aac Reinforced Slab. Precast Or Lintel And Chhajja Shall Be Jointed With Cm 1:6 Or 2 To 3 Mm Thick Polymer Modified Cement Mortar As Per Astmc 1660-09 To Aac Block Masonry. Structural Steel If Used For Providing Support To The Lintels (Such As Cleat Of Angle Iron, C-Section Anchored/Hold Fasted To Column) At Column End Towards (Where Door / Window Opening Is Adjacent To The Column) Shall Not Be Paid Separately. Rate Includes All Handling, Transportation, Hire Charges Of Machineries Scaffolding And Anti- Corrosive Protective Coating On Reinforcement Inside Aac Slab / Lintel/Chhajja Etc. Complete Up To Floor Two Levels. All Reinforcement Of Peripheral Bond Beam, Grooves And Inside Aac Slab, Lintel, And Chhajja Shall Be Paid @ Sor Rate (Including Tender Percentage) Separately. Quantity Of Reinforcement Steel Provided Inside Aac Slab, Lintel And Chhajja Shall Be Ascertained On The Basis Of Manufacturer’S Certificate And Also By Random Destructive Testing Done By Engineer-In-Charge Or His Representative For Which Cost Of Samples And Testing Charges Shall Be Borne By The Contractor. Deflection & Ultimate Load Test For Aac Reinforced Roof Slab And Lintel Shall Be As Per Annex. B Of Is: 6073 -2006 And Criteria For Conformity And Sampling Shall Be As Per Clause-13 Of Is: 6073 -2006. 39 7.1 7.1.1 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4147.0 40 7.2 7.2.1 Cement Mortar 1:6 (1Cement: 6 Sand). Cum 4351.0 41 7.4 7.4.1 Square Or Rectangular Pillars Cum 213.0 7.4.2 Circular Pillars. Cum 894.0 42 7.6 7.6.1 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4603.0 7.6.2 Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4342.0 43 7.7 7.7.1 Masonry Work (First Sort) In Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4803.0 7.7.2 Masonry Work (Second Sort) , In Cement Mortar 1:6 (1 Cement : 6 Sand) Cum 4541.0 44 7.9 7.9.1 Square Or Rectangular Pillars Cum 235.0 7.9.2 Circular Pillars. Cum 1003.0 7.9.3 Extra For Coursed Rubble Masonry With Hard Stone (First Or Second Sort) Curved On Plan For A Mean Radius Not Exceeding 6 M. Cum 384.0 45 7.26 7.26.1 Red Sand Stone: With Common Burnt Clay Bricks Of 25 Kg/Cm2 Compressive Strength. Sqm 1196.0 7.26.2 White Sand Stone With Common Burnt Clay Bricks Of 25 Kg/Cm2 Compressive Strength. Sqm 1196.0 46 7.27 7.27.1 Red Sand Stone Sqm 744.0 7.27.2 White Sand Stone Sqm 744.0 47 7.32 Note: - The Quantity Will Be Calculated By Multiplying The Depth Measured From Sub - Soil Water Level Up To The Centre Of Gravity Of Stone Work Under Sub - Water With The Quantity Of Stone Work In Cum Executed Under The Sub - Soil Water. The Depth Of Centre Of Gravity Shall Be Reckoned Correct To 0.1 M. 0.05 M Or More Shall Be Taken As 0.1 M And Less Than 0.05 M Ignored. 48 8.2 (A) Structural Analysis And Design And Preparation Of Shop Drawings For The Specified Design Loads Conforming To Is 875 Part Iii (The System Must Passed The Proof Test At 1.5 Times Design Wind Pressure Without Any Failure), Including Functional Design Of The Aluminum Sections For Fixing Glazing Panels Of Various Thicknesses, Aluminium Cleats, Sleeves And Splice Plates Etc. Gaskets, Screws, Toggles, Nuts, Bolts, Clamps Etc., Structural And Weather Silicone Sealants, Flashings, Fire Stop (Barrier)-Cum-Smoke Seals, Microwave Cured Epdm Gaskets For Water Tightness, Pressure Equalisation And Drainage And Protection Against Fire Hazard Including: (B) Fabricating And Supplying Serrated M.S. Hot Dip Galvanised / Aluminium Alloy Of 6005 T5 Brackets Of Required Sizes, Sections And Profiles Etc. To Accommodate 3 Dimentional Movement For Achieving Perfect Verticality And Fixing Structural Glazing System Rigidly To The Rcc/ Masonry/Structural Steel Framework Of Building Structure Using Stainless Steel Anchor Fasteners/ Bolts, Nylon Seperator To Prevent Bimetallic Contacts With Nuts And Washers Etc. Of Stainless Steel Grade 316, Of The Required Capacity And In Required Numbers. (C) Providing And Filling, Two Part Pump Filled, Structural Silicone Sealant And One Part Weather Silicone Sealant Compatible With The Structural Silicone Sealant Of Required Bite Size In A Clean And Controlled Factory / Work Shop Environment, Including Double Sided Spacer Tape, Setting Blocks And Backer Rod, All Of Approved Grade, Brand And Manufacture, As Per The Approved Sealant Design, Within And All Around The Perimeter For Holding Glass. (D) Providing And Fixing In Position Flashings Of Solid Aluminium Sheet 1 Mm Thick And Of Sizes, Shapes And Profiles, As Required As Per The Site Conditions, To Seal The Gap Between The Building Structure And All Its Interfaces With Curtain Glazing To Make It Watertight. (E) Making Provision For Drainage Of Moisture/ Water That Enters The Curtain Glazing System To Make It Watertight, By Incorporating Principles Of Pressure Equalization, Providing Suitable Gutter Profiles At Bottom (If Required), Making Necessary Holes Of Required Sizes And Of Required Numbers Etc. Complete. This Item Includes Cost Of All Inputs Of Designing, Labour For Fabricating And Installation Of Aluminium Grid, Installation Of Glazed Units, Tandp, Scaffolding And Other Incidental Charges Including Wastages Etc., Enabling Temporary Structures And Services, Cranes Or Cradles Etc. As Described Above And As Specified. The Item Includes The Cost Of Getting All The Structural And Functional Design Including Shop Drawings Checked By A Structural Designer, Dully Approved By Engineer-In-Charge. The Item Also Includes The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Structural Glazing As Specified, Cleaning And Protection Till The Handing Over Of The Building For Occupation. In The End, The Contractor Shall Provide A Water Tight Structural Glazing Having All The Performance Characteristics Etc. All Complete As Required, As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineerin- Charge. Note: - 1. The Cost Of Providing Extruded Aluminium Frames, Shadow Boxes, Extruded Aluminium Section Capping For Fixing In The Grooves Of The Curtain Glazing And Vermin Proof Stainless Steel Wire Mesh Shall Be Paid For Separately Under Relevant Items Under This Sub- Head. However, For The Purpose Of Payment, Only The Actual Area Of Structural Glazing (Including Width Of Grooves) On The External Face Shall Be Measured In Sqm. Upto Two Decimal Places.Note: 2. The Following Performance Test Are To Be Conducted On Structural Glazing System If Area Of Structural Glazing Exceeds 2500 Sqm From The Certified Laboratories Accreditated By Nabl (National Accreditation Board For Testing And Calibration Laboratories), Department Of Science And Technologies, India. Cost Of Testing Is Inclusive In The Rates. Performance Testing Of Structural Glazing System Tests To Be Conducted In The Nabl Certified Laboratories(1) Performance Laboratory Test For Air Leakage Test (-50Pa To – 300Pa) And (+50Pa To +300Pa) As Per Astm E-283-04 Testing Method For A Range Of Testing Limit 1 To 200 Mvhr”(2) Static Water Penetration Test. (50Pa To 1500Pa) As Per Astme- 331-09 Testing Method For A Range Upto 2000 Ml.”(3) Dynamic Water Penetration (50Pa To 1500Pa) As Per Aama 501.01-05 Testing Method For A Range Upto 2000 Ml”(4) Structural Performance Deflection And Deformation By Static Air Pressure Test (1.5 Times Design Wind Pressure Without Any Failure) As Per Astme-330-10 Testing Method For A Range Upto 50 Mm”(5) Seismic Movement Test (Upto 30 Mm) As Per Aama 501.4-09 Testing Method For Qualitative Test” Tests To Be Conducted On Site (6) Onsite Test For Water Leakage For A Pressure Range 50 Kpa To 240 Kpa (35Psi) Upto 2000Ml” 49 8.3 (I) Coloured Tinted Float Glass 6Mm Thick Substrate With Reflective Soft Coating On Face # 2, + 12Mm Airgap + 6Mm Heat Strengthened Clear Glass Of Approved Make Having Properties As Visible Light Transmittance (Vlt) Of 25 To 35 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 Degree K Etc. The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 50 8.5 The Insulation Layer Shall Have Facing (Factory Bonded On Surface # 1 Of The Fibre Glass Insulation Layer), Of Black Non- Woven Fibre Glass Tissue Of Nominal Thickness 0.5 Mm And Nominal Mass Not Less Than 60 Gm/Sqm, Made Of Randomly Oriented Glass Fibres Distributed In A Binder By A Wet-Lay Process Including Fixing 1.5 Mm Thick Solid Aluminum Sheet Backing Using, 6 Mm Thick Cement Board Including Ss Rivets, Nuts, Bolts,Washers Etc Complete. 51 8.6 %, Light Reflection Internal 10 To 15%, Light Reflection External 10 To 20 %, Shading Coefficient (0.25- 0.28) And U Value Of 3.0 To 3.3 W/M2 Degree K Etc. The Properties Of Performance Glass Shall Be Decided By Technical Sanctioning Authority As Per The Site Requirement. 52 8.7 A) Structural Analysis And Design And Preparation Of Shop Drawings For Pressure Equalisation Or Rain Screen Principle As Required, Proper Drainage Of Water To Make It Watertight Including Checking Of All The Structural And Functional Design. B) Providing, Fabricating And Supplying And Fixing Panels Of Aluminium Composite Panel Cladding In Pan Shape In Metalic Colour Of Approved Shades.The Aluminium Composite Panel Cladding Sheet Shall Be Coil Coated, With Kynar 500 Based Pvdf / Fluoropolymer Resin Coating Of Approved Colour And Shade On Face # 1 And Polymer (Service) Coating On Face # 2 As Specified Using Stainless Steel Screws, Nuts, Bolts, Washers, Cleats, Weather Silicone Sealant, Backer Rods Etc. C) The Fastening Brackets Of Aluminium Alloy 6005 T5 / Ms With Hot Dip Galvanised With Serrations And Serrated Washers To Arrest The Wind Load Movement, Fasteners, Ss 316 Pins And Anchor Bolts Of Approved Make In Ss 316, Nylon Separators To Prevent Bi-Metallic Contacts All Complete Required To Perform As Per Specification And Drawing The Item Includes Cost Of All Material And Labour Component, The Cost Of All Mock Ups At Site, Cost Of All Samples Of The Individual Components For Testing In An Approved Laboratory, Field Tests On The Assembled Working Curtain Wall With Aluminium Composite Panel Cladding, Cleaning And Protection Of The Curtain Wall With Aluminium Composite Panel Cladding Till The Handing Over Of The Building For Occupation. Base Frame Work For Acp Cladding Is Payable Under The Relevant Aluminium Items. The Contractor Shall Provide Curtain Wall With Aluminium Composite Panel Cladding, Having All The Performance Characteristics All Complete, As Per The Architectural Drawings, As Per Item Description, As Specified, As Per The Approved Shop Drawings And As Directed By The Engineer- In-Charge. However, For The Purpose Of Payment, Only The Actual Area On The External Face Of The Curtain Wall With Aluminum Composite Panel Cladding (Including Width Of Groove) Shall Be Measured In Sqm. Upto Two Decimal Places. 4 Mm Thick Alumminium Composite Pannel Material Consisting Of 3 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.5Mm Thick) Sqm 3800.0 4 Mm Thick Alumminium Composite Pannel Material Consisting Of 3.5 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.25Mm Thick) Sqm 3556.0 3 Mm Thick Alumminium Composite Pannel Material Consisting Of 2.5 Mm Thick Fr Grade Mineral Core Sandwiched Between Two Alumminium Sheets (Each 0.25Mm Thick) Sqm 3312.0 53 9.1 9.1.1 Second Class Teak Wood Cum 90618.0 9.1.2 Sal Wood Cum 71309.0 9.1.3 Kiln Head Wood Seasoned And Chemically Treated Hard Wood (Haldu, Kail, Bija Wood.) Cum 72744.0 9.1.4 Factory Made Kiln Seasoned, Chemically Treated, Finger Jointed At Spacing Not Closer Than 50 Cm, 2Nd Class Hard Wood 9.1.4.1 Frame Of Size 100Mmx60Mm Single Or Double Rebate Meter 389.0 9.1.4.2 Frame Of Size 120Mmx60Mm Double Rebate. Meter 457.0 54 9.3 9.3.1 Sal Wood Cum 76229.0 9.3.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. Cum 77538.0 9.3.3 Factory Made Kiln Seasoned, Chemically Treated, Finger Jointed At Spacing Not Closer Than 50 Cm, 2Nd Class Hard Wood. Cum 64833.0 55 9.5 9.5.1 Second Class Teak Wood 9.5.1.1 35 Mm Thick Shutters Sqm 2776.0 9.5.1.2 30 Mm Thick Shutters Sqm 2448.0 9.5.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. 9.5.2.1 35 Mm Thick Shutters Sqm 2205.0 9.5.2.2 30 Mm Thick Shutters Sqm 1956.0 9.5.3 Kiln Seasoned Selected Planks Of Sheesham Wood. 9.5.3.1 35 Mm Thick Shutters Sqm 2060.0 9.5.3.2 30 Mm Thick Shutters Sqm 1816.0 9.5.4 Factory Made Kiln Seasoned Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood Shutters 9.5.4.1 35 Mm Thick Sqm 1089.0 9.5.4.2 30 Mm Thick Sqm 969.0 56 9.6 9.6.1 Second Class Teak Wood Sqm 2215.0 9.6.2 Kiln Seasoned And Chemically Treated Hardwood Haldu, Kail, Bija Wood. Sqm 1763.0 9.6.3 15Mm Thick Factory Made Kiln Seasoned, Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood. Sqm 971.0 9.6.4 Ply Wood 5 Ply, 9 Mm Thick : 9.6.4.1 Decorative Plywood Both Side Decorative Veneer (Type - I) Conforming To Is 1328 Bwr Type. Sqm 1439.0 9.6.4.2 Decorative Plywood One Side Decorative Veneer And Commercial Veneer On Other Face (Type 1) Conforming To Is 1328 Bwr Type Sqm 1369.0 9.6.5 Ply Wood 7 Ply, 9 Mm Thick : 9.6.5.1 Decorative Plywood Both Side Decorative Veneer (Type - I) Conforming To Is 1328 Bwr Type. Sqm 1861.0 9.6.5.2 Decorative Plywood One Side Decorative Veneer And Commercial Veneer On Other Face (Type 1) Conforming To Is 1328 Bwr Type Sqm 1650.0 9.6.6 Particle Board 12 Mm Thick 9.6.6.1 Plain Particle Board Flat Pressed, 3 Layer Or Graded Wood Particle Board Medium Density Grade I, Is: 3087 Marked. Sqm 791.0 9.6.6.2 Veneered Flat Pressed Three Layer Or Graded Wood Particle Board With Commercial Veneering On Both Sides Conforming To Is: 3097, Grade I. Sqm 1087.0 9.6.6.3 Pre-Laminated Particle Board With Sqm 1333.0 Decorative Lamination On One Side And Balancing Lamination On Other Side, Grade I, Type Ii Is: 12823 Marked. 9.6.6.4 Pre-Laminated Particle Board With Decorative Lamination On Both Sides, Grade I, Type Ii, Is: 12823 Marked. Sqm 1390.0 9.6.6.5 Coir Veneer Board (Conforming To Is 14842) 12 Mm Thick Sqm 1298.0 9.6.7 Float Glass Panes 9.6.7.1 4 Mm Thick Glass Pane (Weight Not Less Than 10 Kg/Sqm) Sqm 973.0 9.6.7.2 5 Mm Thick Glass Pane (Weight Not Less Than 12.5 Kg/Sqm) Sqm 1046.0 9.6.8 Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia. Wire And 1.4 Mm Wide Aperture With Matching Wood Beading Sqm 1532.0 9.6.8.1 4Mm To 5Mm Thick Integral Pvc Form Sheet With Celluka Finish Surface On Both Side With Density Not Less Than 600 Kg/Cum Sqm 580.0 9.6.8.2 4Mm To 5Mm Thick Laminated Pvc Form Sheet With Density Not Less Than 600 Kg/Cum, Laminated On Both Sides By 0.12 Mm Thick Laminated Sheet With Density Not Less Than 1400 Kg/Cum Sqm 754.0 57 9.7 9.7.1 12Mm Thick Plain Grade - 1, Medium Density Flat Pressed Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt - I Is : 3087 Marked Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 : Sqm 2717.0 9.7.2 12 Mm Thick Pre-Laminated Particle Board (Decorative Lamination On Both Sides) Grade - 1, Medium Density Flat Pressed, Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt - I, Conforming To Is : 3087 Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Pre- Lamination Conforming To Is : 12823 Grade 1, Type - Ii Marked: Sqm 2868.0 9.7.3 12 Mm Thick One Side Pre-Laminated Particle Board (Decorative Lamination On One Side And Other Sides Balancing Lamination) Grade - 1 Medium Density Flat Pressed, Three Layer Particle Board Fpt - I Or Graded Wood Particle Board Fpt-1 Conforming To Is : 3087 Bonded With Bwp Type Synthetic Resin Adhesive As Per Is : 848 And Prelamination Conforming To Is : 12823 Grade -1, Type Ii Marked: Sqm 2775.0 58 9.8 9.8.1 Second Class Teak Wood 9.8.1.1 35 Mm Thick Sqm 3408.0 9.8.1.2 30 Mm Thick Sqm 3033.0 9.8.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood 9.8.2.1 35 Mm Thick Sqm 2758.0 9.8.2.2 30 Mm Thick Sqm 2474.0 9.8.3 Kiln Seasoned Selected Planks Of Sheesham Wood. 9.8.3.1 35 Mm Thick Sqm 2594.0 9.8.3.2 30 Mm Thick Sqm 2331.0 9.8.4 Factory Made Kiln Seasoned Chemically Treated And Finger Jointed At Spacing Not Closer Than 50Cm, 2Nd Class Hard Wood Shutters 9. 8.4.1 30 Mm Thick Shutters Sqm 1469.0 9. 8.4.2 35 Mm Thick Shutters Sqm 1589.0 59 9.1 9.10.1 5 Mm Thick Instead Of 4 Mm Thick. Sqm 73.0 9.10.2 10 To 12 Mm Float Glass Sqm 132.0 9.10.3 5.5 Mm Safety Glass Sqm 400.0 9.10.4 10-12Mm Safety Glass Sqm 960.0 60 9.13 Deduct For Not Providing Hinges In Doors, Windows Or Clerestory Window Shutters With : 9.14.1 Stainless Steel Butt Hinges With Stainless Steel Screws For 2Nd Class Teak Wood And Other Class Of Wood Shutters. Sqm 170.0 9.14.2 Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size For 2Nd Class Teak Wood And Other Class Of Wood Shutters. Sqm 53.0 61 9.15 9.15.1 Panelled Or Panelled And Glazed Shutters : 9.15.1.1 Using Isi Marked Anodised Aluminium Butt Hinges With Necessary Screws. Sqm 2736.0 9.15.1.2 Using Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2753.0 9.15.2 Glazed Shutters : 9.15.2.1 Second Class Teak Wood Including Isi Marked Anodised Aluminium Butt Hinges With Necessary Screws. Sqm 2815.0 9.15.2. 2Nd Class Teak Wood Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2759.0 62 9.16 9.16.1 12 Mm Thick Sqm 555.0 9.16.2 18 Mm Thick Sqm 654.0 63 9.17 9.17.1 18 Mm Thick Sqm 1270.0 9.17.2 25 Mm Thick Sqm 1383.0 64 9.18 9.18.1 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 2600.0 9.18.2 30 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 2370.0 9.18.3 25 Mm Thick (For Cupboard) Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges Is: 3818 Marked With Necessary Screws. Sqm 2119.0 65 9.19 9.19.1 35 Mm Thick Including Isi Marked Stainless Steel Butt Hinges With Necessary Screws. Sqm 1622.0 9.19.2 30 Mm Thick Including Isi Marked Sqm 1564.0 Stainless Steel Butt Hinges With Necessary Screws. 9.19.3 25Mm Thick (For Cupboard) Including Isi Marked Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 1533.0 66 9.22 9.22.1 Rectangular Or Square. Sqm 157.0 9.22.2 Circular. Sqm 244.0 67 9.25 9.25.1 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.25.1.1 Second Class Teak Wood. Sqm 3174.0 9.25.1.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2599.0 9.25.1.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2452.0 9.25.2 35 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.25.2.1 Second Class Teak Wood. Sqm 3291.0 9.25.2.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2716.0 9.25.2.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2569.0 9.25.3 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.25.3.1 Second Class Teak Wood. Sqm 2797.0 9.25.3.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2306.0 9.25.3.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2179.0 9.25.4 30 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.25.4.1 Second Class Teak Wood. Sqm 2914.0 9.25.4.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2423.0 9.25.4.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2296.0 68 9.26 9.26.1 35 Mm Thick Shutters Sqm 2427.0 9.26.2 30 Mm Thick Shutters Sqm 2102.0 69 9.28 9.28.1 25 Mm Long Each 16.0 9.28.2 32 Mm Long Each 18.0 9.28.3 40 Mm Long Each 21.0 9.28.4 50 Mm Long Each 25.0 9.28.5 60 Mm Long Each 28.0 70 9.29 9.29.1 40 Mm Thick. Sqm 5407.0 9.29.2 25 Mm Thick. Sqm 3469.0 9.29.3 20 Mm Thick Sqm 2802.0 9.29.4 12 Mm Thick Sqm 1768.0 71 9.3 9.30.1 12 Mm Thick Sqm 1174.0 9.30.2 18 Mm Thick Sqm 1410.0 9.30.3 25 Mm Thick Sqm 1525.0 72 .9.32 73 9.34 9.34.1 18 Mm Thick Sqm 1626.0 9.34.2 25 Mm Thick Sqm 1741.0 74 9.35 9.35.1 2Nd Class Teak Wood 9.35.1.1 50X12 Mm Metre 102.0 9.35.1.2 50 X 20 Mm Metre 147.0 9.35.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. 9.35.2.1 50X12 Mm Metre 85.0 9.35.2.2 50X20 Mm Metre 119.0 75 9.39 9.39.1 Non Decorative Veneer On Both Sides. Metre 34.0 9.39.2 Particle Board With Decorative Veneering On Both Sides. Metre 102.0 76 9.41 9.41.1 12 Mm Dia. Metre 289.0 9.41.2 20 Mm Dia. Metre 377.0 9.41.3 25 Mm Dia. Metre 382.0 77 9.42 9.42.1 20 Mm Dia (Heavy Type) Metre 127.0 9.42.2 25 Mm Dia (Heavy Type) Metre 141.0 78 9.43 9.43.1 Fixed To Steel Windows By Welding. Kg 91.0 9.43.2 Fixed To Openings /Wooden Frames With Rawl Plugs Screws Etc. Kg 100.0 79 9.46 9.46.1 With 2Nd Class Teak Wood Beading 62X19 Mm. Sqm 1000.0 9.46.2 With 12 Mm Mild Steel U Beading. Sqm 681.0 80 9.5 9.50.1 125X65X2.12 Mm Each 30.0 9.50.2 100X58X1.90 Mm Each 23.0 9.50.3 75X47X1.70 Mm Each 18.0 9.50.4 50X37X1.50 Mm Each 10.0 81 9.51 9.51.1 125X90X4.00 Mm Each 53.0 9.51.2 100X75X3.50 Mm Each 35.0 9.51.3 75X60X3.10 Mm Each 21.0 9.51.4 50X40X2.50 Mm Each 13.0 82 9.52 9.52.1 125X65X2.12 Mm Each 32.0 9.52.2 100X58X1.90 Mm Each 23.0 9.52.3 75X47X1.70 Mm Each 17.0 9.52.4 50X37X1.50 Mm Each 10.0 83 9.53 9.53.1 150X125X27X2.80 Mm Each 58.0 9.53.2 125X125X27X2.80 Mm Each 55.0 9.53.3 100X125X27X2.80 Mm Each 46.0 9.53.4 75X100X20X2.24 Mm Each 39.0 84 9.54 9.54.1 150 Mm Each 169.0 9.54.2 125 Mm Each 163.0 9.54.3 100 Mm Each 131.0 85 9.55 9.55.1 150 Mm Each 174.0 9.55.2 125 Mm Each 163.0 9.55.3 100 Mm Each 137.0 86 9.56 9.56.1 Overall Width 35 Mm. Metre 133.0 9.56.2 Overall Width 50 Mm. Metre 138.0 9.56.3 Overall Width 65 Mm. Metre 141.0 87 9.57 9.57.1 300X16 Mm Each 170.0 9.57.2 250X16 Mm Each 157.0 88 9.58 9.58.1 250X10 Mm Each 68.0 9.58.2 200X10 Mm Each 60.0 9.58.3 150X10 Mm Each 42.0 9.58.4 100X10 Mm Each 35.0 89 0.6 9.60.1 300X20X6 Mm Each 72.0 9.60.2 250X20X6 Mm Each 67.0 90 9.61 9.61.1 125 Mm Each 27.0 9.61.2 100 Mm Each 25.0 9.61.3 75 Mm Each 24.0 91 9.62 9.62.1 150 Mm Each 23.0 9.62.2 115 Mm Each 20.0 9.62.3 90 Mm Each 17.0 92 9.63 9.63.1 300 Mm Weighing Not Less Than 200 Gms. Each 40.0 9.63.2 250 Mm Weighing Not Less Than 150 Gms. Each 34.0 9.63.3 200 Mm Weighing Not Less Than 120 Gms. Each 28.0 93 9.65 9.65.1 300X16 Mm Each 389.0 9.65.2 250X16 Mm Each 326.0 94 9.66 9.66.1 250X10 Mm Each 148.0 9.66.2 200X10 Mm Each 93.0 9.66.3 150X10 Mm Each 71.0 9.66.4 100X10 Mm Each 50.0 95 9.68 9.68.1 300X20X6 Mm Each 211.0 9.68.2 250X20X6 Mm Each 173.0 96 9.69 9.69.1 125 Mm Each 60.0 9.69.2 100 Mm Each 54.0 9.69.3 75 Mm Each 48.0 97 9.7 9.70.1 150 Mm Each 37.0 9.70.2 115 Mm Each 33.0 9.70.3 90 Mm Each 26.0 98 9.71 9.71.1 300 Mm Weighing Not Less Than 200 Gms. Each 79.0 9.71.2 250 Mm Weighing Not Less Than 150 Gms. Each 61.0 9.71.3 200 Mm Weighing Not Less Than 120 Gms. Each 49.0 99 9.73 9.73.1 125X64X1.90 Mm Each 67.0 9.73.2 100X58X1.90 Mm Each 59.0 9.73.3 75X47X1.80 Mm Each 39.0 9.73.4 50X37X1.50 Mm Each 25.0 100 9.74 9.74.1 125X64X2.50 Mm Each 76.0 9.74.2 100X60X2.50 Mm Each 60.0 9.74.3 75X50X2.50 Mm Each 46.0 101 9.77 9.77.1 125X85X5.5 Mm (Heavy Type) Each 456.0 9.77.2 125X70X4 Mm (Ordinary Type) Each 148.0 9.77.3 100X85X5.5 Mm (Heavy Type) Each 387.0 9.77.4 100X70X4 Mm (Ordinary Type) Each 117.0 9.77.5 75X65X4 Mm (Heavy Type) Each 145.0 9.77.6 75X40X2.5 Mm (Ordinary Type) Each 74.0 9.77.7 50X40X2.5 Mm (Ordinary Type) Each 32.0 102 9.78 9.78.1 150X125X27X5 Mm Each 385.0 9.78.2 125X125X27X5 Mm Each 345.0 9.78.3 100X125X27X5 Mm Each 304.0 9.78.4 75X100X20X3.2 Mm Each 239.0 103 9.79 9.79.1 400X10 Mm Each 400.0 9.79.2 250X10 Mm Each 329.0 9.79.3 200X10 Mm Each 261.0 9.79.4 150X10 Mm Each 221.0 9.79.5 100X10 Mm Each 142.0 104 9.8 9.80.1 300X16X5 Mm Each 237.0 9.80.2 250X16X5 Mm Each 225.0 105 9.81 9.81.1 125 Mm Each 205.0 9.81.2 100 Mm Each 181.0 9.81.3 75 Mm Each 141.0 106 9.82 9.82.1 300X16Mm Each 407.0 9.82.2 250X16Mm Each 374.0 107 9.87 9.87.1 40 Mm Each 144.0 9.87.2 50 Mm Each 150.0 9.87.3 65 Mm Each 162.0 9.87.4 75 Mm Each 185.0 108 9.39 9.91.1 300 Mm Weighing Not Less Than 330 Gms Each 184.0 9.91.2 250 Mm Weighing Not Less Than 280 Gms Each 147.0 9.91.3 200 Mm Weighing Not Less Than 240 Gms Each 136.0 109 9.92 9.92.1 150 Mm Each 115.0 9.92.2 115 Mm Each 94.0 9.92.3 90 Mm Each 80.0 110 9.99 9.99.1 Size 40 Mm Each 144.0 9.99.2 Size 50 Mm Each 156.0 9.99.3 Size 65 Mm Each 167.0 9.99.4 Size 75 Mm Each 196.0 111 9.101 9.101.1 300X16Mm Each 268.0 9.101.2 250X16Mm Each 245.0 112 9.102 9.102.1 400X10Mm Each 260.0 9.102.2 300X10Mm Each 198.0 9.102.3 250X10Mm Each 164.0 9.102.4 200X10 Mm Each 113.0 9.102.5 150X10 Mm Each 91.0 9.102.6 100X10 Mm Each 73.0 113 9.1 9.103.1 300X16X5Mm Each 255.0 9.103.2 250X16X5Mm Each 243.0 114 9.104 115 9.105 9.105.1 125 Mm Each 241.0 9.105.2 100 Mm Each 206.0 9.105.3 75 Mm Each 182.0 116 9.106 117 9.107 9.107.1 300 Mm Weighing Not Less Than 330 Gms Each 207.0 9.107.2 250 Mm Weighing Not Less Than 280 Gms Each 178.0 9.107.3 200 Mm Weighing Not Less Than 240 Gms Each 149.0 118 9.108 Note:- Aluminum Hinges Shall Not Be Used In Wooden Shutters. 9.108.1 125X75X4 Mm Each 115.0 9.108.2 125X63X4 Mm Each 108.0 9.108.3 100X75X4 Mm Each 95.0 9.108.4 100X63X4 Mm Each 93.0 9.108.5 100X63X3.2 Mm Each 90.0 9.108.6 75X63X4 Mm Each 77.0 9.108.7 75X63X3.2 Mm Each 75.0 9.108.8 75X45X3.2 Mm Each 67.0 119 9.109 9.109.1 300X16 Mm Each 241.0 9.109.2 250X16 Mm Each 195.0 120 9.11 9.110.1 400X10Mm Each 123.0 9.110.2 300X10 Mm Each 114.0 9.110.3 250X10 Mm Each 102.0 9.110.4 200X10 Mm Each 82.0 9.110.5 150X10 Mm Each 69.0 9.110.6 100X10 Mm Each 55.0 121 9.111 122 9.112 123 9.113 9.113.1 125 Mm Each 75.0 9.113.2 100 Mm Each 55.0 9.113.3 75 Mm Each 46.0 124 9.114 9.114.1 Single Rubber Stopper Each 35.0 9.114.2 Twin Rubber Stopper Each 86.0 125 9.115 126 9.116 127 9.117 128 9.118 9.118.1 125X34X24 Mm Weighing Not Less Than 23 Gms. Each 44.0 9.118.2 150X34X24 Mm Weighing Not Less Than 26 Gms. Each 48.0 129 9.119 9.119.1 75X60X10 Mm Fitted With 5.5 Mm Dia M.S. Bright Bar Rod Weighing Not Less Than 34 Gms. Each 62.0 9.119.2 100X75X10 Mm Fitted With 5.5 Mm Dia Ms Bright Bar Rod Weighing Not Less Than 53 Gms. Each 82.0 130 9.12 9.120.1 152X42X18 Mm Weighing Not Less Than 60 Gms. Each 87.0 9.120.2 202X42X18 Mm Weighing Not Less Than 78 Gms. Each 106.0 131 9.121 132 9.122 133 9.123 9.123.1 35 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.1.1 Second Class Teak Wood. Sqm 3583.0 9.123.1.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 3008.0 9.123.1.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2862.0 9.123.2 35 Mm Thick Shutters With Isi Marked Stainless Steel Butt Hinges Of Required Size. 9.123.2.1 Second Class Teak Wood. Sqm 3700.0 9.123.2.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 3125.0 9.123.2.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2979.0 9.123.3 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.3.1 Second Class Teak Wood. Sqm 3206.0 9.123.3.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2715.0 9.123.3.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2589.0 9.123.4 30 Mm Thick Shutters With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size. 9.123.4.1 Second Class Teak Wood. Sqm 3323.0 9.123.4.2 Kiln Seasoned And Chemically Treated Haldu, Kail, Bija Wood. Sqm 2832.0 9.123.4.3 Kiln Seasoned Selected Class Of Sheesham Wood. Sqm 2706.0 134 9.124 9.124.1 With 2Nd Class Teak Wood Beading 62X19 Mm. Sqm 1689.0 9.124.2 With 12 Mm Mild Steel U Beading. Sqm 1370.0 135 9.126 136 9.127 137 9.128 138 9.129 9.129.1 Triple Strip Vertical Type. Each 28.0 9.129.2 Double Strip (Horizontal Type). Each 23.0 139 9.131 9.131.1 300Mm Long Each Set 209.0 9.131.2 450Mm Long Each Set 256.0 9.131.3 500Mm Long Each Set 302.0 140 9.132 141 9.133 9.133.1 Marine Plywood Conforming To Is: 710 Sqm 1591.0 9.133.2 Fire Retardant Plywood Conforming To Is: 5509 Sqm 1660.0 142 9.134 9.134.1 1.5 Mm Thick. Sqm 851.0 9.134.2 1.0 Mm Thick. Sqm 691.0 143 9.135 144 9.136 9.136.1 With Decorative Veneering On One Side And Commercial Veneering On Other Side. Sqm 1433.0 9.136.2 With Non Decorative Veneering On Both Sides. Sqm 1322.0 145 9.137 146 9.138 9.138.1 12 Mm Thick. Sqm 919.0 9.138.2 18 Mm Thick. Sqm 1161.0 9.138.3 25 Mm Thick. Sqm 1230.0 147 9.139 148 9.14 9.140.1 18 Mm Thick Sqm 1493.0 9.140.2 25 Mm Thick Sqm 2017.0 149 9.143 25Mm To 40Mm Thick: Pre-Laminated With Decorative Lamination On Both Side Exterior Grade - I Mdf Board 12 Mm Thick Confirming To Is:14587 150 9.145 9.145.1 Board 12 Mm Thick Sqm 811.0 9.145.2 Board 18 Mm Thick Sqm 943.0 151 9.146 9.146.1 18 Mm Thick Sqm 1055.0 9.146.2 25 Mm Thick Sqm 1420.0 152 9.158 9.158.1 Extruded Section Profile Size 48X40 Mm. Metre 203.0 9.158.2 Extruded Section Profile Size 42X50 Mm. Metre 208.0 153 9.159 154 9.161 155 9.165 156 9.166 9.166.1 Plain Pvc Door Shutters. Sqm 2026.0 9.166.2 Pre Laminated Pvc Door Shutters. Sqm 2490.0 157 9.167 158 9.168 Non Decorative Finish. Sqm 2026.0 Decorative Finish (Both Side Wood Grained Finish). Sqm 2432.0 159 9.175 160 9.176 9.176.1 Non Decorative Finish (Matt Finish). Sqm 2037.0 9.176.2 Decorative Finish (Wood Grained Finish). Sqm 2142.0 161 9.177 162 9.182 163 9.183 164 9.184 165 9.185 166 9.186 167 9.187 9.187.1 Casement Window (Outward/Inward Opening) With Hinge System. 9.187.1.1 Frame (50 Mm X 50Mm) Metre 422.0 9.187.1.2 Sash (Style And Rail) (62 Mm X 34 Mm) Metre 403.0 9.187.1.3 Mullion (Intermediate Section) (66Mm X 50 Mm) Metre 434.0 9.187.1.4 ‘T Profile (One Vertical Length In Between Two Shutters) (24Mm X 34.5Mm) Metre 99.0 9.187.1.5 Glazing Bead (12Mm X 18Mm) Metre 130.0 9.187.2 Casement Window (With Friction Hinge And Outward Opening) 9.187.2.1 Casement Frame (67Mm X 62Mm) Metre 495.0 9.187.2.2 Casement Window Sash/Mullion (67Mm X75Mm) (Style, Rail And Intermediate Section) Metre 519.0 9.187.2.3 Casement Glazing Bead (35Mm X 18 Mm) Metre 178.0 9.187.3 Sliding Window (Two Track, 2/4 Shutters) 9.187.3.1 Two Track Sliding Frame (67Mm X 52Mm) Metre 9.187.3.2 Sliding Window Sash (60Mm X 44Mm) Metre 529.0 9.187.3.3 Sliding Interlock For Window (One Vertical Length In Each Shutter)(45.5 Mm X 28 Mm) Metre 139.0 9.187.3.4 Sliding Glazing Bead (35 Mm X 18 Mm) Metre 178.0 9.187.4 Sliding Door (Two Track, 2/4 Shutters) 9.187.4.1 Two Track Sliding Frame (67Mm X 52Mm) Metre 539.0 9.187.4.2 Sliding Door Sash (80Mm X 44Mm) Metre 653.0 9.187.4.3 Sliding Interlock For Door (One Vertical Length In Each Shutter) (45.5 Mm X 28 Mm) Metre 139.0 9.187.4.4 Sliding Glazing Bead (35 Mm X 18 Mm) Metre 178.0 168 9.188 9.188.1 200 X 19 X 1.9 Mm Each 321.0 9.188.2 250 X 19 X 1.9 Mm Each 369.0 9.188.3 300 X 19 X 1.9 Mm Each 462.0 9.188.4 350 X 19 X 1.9 Mm Each 526.0 9.188.5 400 X 19 X 1.9 Mm Each 636.0 169 9.189 170 9.191 171 9.192 172 9.193 173 9.194 Of Water Etc. After Fixing Frame The Gap Between Frame And Adjacent Finished Wall Shall Be Filled With Weather Proof Silicon Sealant Over Backer Rod Of Required Size And Of Approved Quality, All Complete As Per Approved Drawing & Direction Of Engineer-In-Charge. (Single / Double Glass Panes And Silicon Sealant Shall Be Paid Separately) Note: For Upvc Frame, Sash And Mullion Extruded Profiles Minus 5% Tolerancein Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 0.75 Sqm.) 9.193.1 Casement Window Single Panel With S.S. Friction Hinges (300 X 19 X 1.9 Mm), Made Of (Small Series) Frame 47 X 50 Mm & Sash 47 X 68 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glass Pane Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 0.75 Sqm.) Sqm 6798.0 9.193.2 Casement Window Double Panels With S.S. Friction Hinges (300 X 19 X 1.9 Mm) Made Of (Small Series) Frame 47 X 50 Mm, Sash 47 X 68 Mm & Mullion 47 X 68 Mm All Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Above 0.75 Sqm Upto 1.50 Sqm). Sqm 6221.0 9.193.3 Casement Window Double Panels With Top Fixed With S.S. Friction Hinges (350 X 19 X 1.9 Mm) Made Of (Small Series) Frame 47 X 50 Mm, Sash 47 X 68 Mm & Mullion 47 X 68 Mm All Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 2.50 Sqm). Sqm 4842.0 9.193.4 Casement Window Single Panel With S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Sqm 6681.0 9.193.5 Casement Window Duble Panel With S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.50 Sqm.) Sqm 6942.0 9.193.6 Casement Cum Fixed Panel Window Having Both And Single Casement Panel, Middle Fixed Panels And At Top Completely Fixed Ventilator With S.S. Friction Hinges (350 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 60 Mm & Sash 67 X 80 Mm & Mullion 67 X 80 All Having Wall Thickness Of 2.3 ±0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 3.00 Sqm. Upto 5.00 Sqm.) Sqm 5290.0 174 9.0 194.1 Fixed Window / Ventilator Made Of (Small Series) Frame 47 X 50 Mm & Mullion 47 X 68 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Upto 0.75 Sqm.) Sqm 4860.0 175 9.195 9.195.1 Casement Door With 3D Hinges Made Of (Big Series) Frame 67 X 64 Mm & Sash 67 X 110 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.00 Sqm). 9.195.2 Casement Door With Top Hung Ventilator With 3D And S.S. Friction Hinges (400 X 19 X 1.9 Mm) Made Of (Big Series) Frame 67 X 64 Mm, Sash 67 X 110 Mm & Mullion 67 X 80 Mm All Having Wall Thickness Of 2.3 ±.0.2 Mm And Single Glazing Bead /Double Glazing Bead Of Appropriate Dimension. (Area Of Door Upto 2.50 Sqm). 176 9.196 Note: - For Upvc Frame, Sash And Mullion Extruede Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 9.196.1 Two Track Two Panels Sliding Window Made Of Frame 52 X 44 Mm &Sash 32 X 60Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension. (Area Of Window Upto 1.75 Sqm) Sqm 5060.0 9.196.2 Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension (Area Of Window Upto 1.75 Sqm). Sqm 6880.0 9.196.3 Two Track Two Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension (Area Of Window Above 1.75 Sqm Upto 2.50 Sqm). Sqm 5134.0 9.196.4 Three Track Three Panels Sliding Window With Fly Proof Ss Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 92 X 44 Mm & Sash 32 X 60 Mm Both Having Wall Thickness Of 1.9 ± 0.2 Mm And Single Glazing Bead Of Appropriate Dimension (Area Of Glazed & One No. Wire Mesh Panels) Made Of Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead/Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm). Sqm 6371.0 9.196.5 Three Track Three Panels Sliding Window Made Of Frame 116 X 45 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 1.75 Sqm) Sqm 5913.0 177 9.197 Note: - For Upvc Frame, Sash And Mullion Extruede Profiles Minus 5% Tolerance In Dimension I.E. In Depth & Width Of Profile Shall Be Acceptable. Variation In Profile Dimension In Higher Side Shall Be Accepted But No Extra Payment On This Account Shall Be Made. 9.197.1 Two Track Two Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 2.50 Sqm Upto 4.00 Sqm). Sqm 4332.0 9.197.2 Two Track Four Panels Sliding Window Made Of Frame 67 X 50 Mm & Sash 46 X 62 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Window Above 4.00 Sqm Upto 8.00 Sqm). Sqm 3532.0 178 9.198 9.198.1 Two Track Two Panels Sliding Door Made Of Frame 67 X 50 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 2.00 Sqm Upto 10.00 Sqm). Sqm 3676.0 9.198.2 Two Track Four Panels Sliding Door Made Of Frame 67 X 50 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 8.00 Sqm Upto10.00 Sqm). Sqm 3810.0 9.198.3 Three Track Three Panels Sliding Door Made Of Frame 116 X 45 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead/ Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 5.00 Sqm) Sqm 4361.0 9.198.4 Three Track Three Panels Sliding Door With Fly Proof S.S Wire Mesh (Two Nos. Glazed & One No. Wire Mesh Panels) Made Of Frame 116 X 45 Mm & Sash 46 X 82 Mm Both Having Wall Thickness Of 2.3 ± 0.2 Mm And Single Glazing Bead / Double Glazing Bead Of Appropriate Dimension. (Area Of Door Above 2.00 Sqm Upto 5.00 Sqm) Sqm 5617.0 179 9.199 180 9.2 9.200.1 24 To 25 Mm Thick Plain Solid Pvc Flush Door Shutter 9.200.2 28 To 30 Mm Thick Plain Solid Pvc Flush Door Shutter 181 9.201 9.201.1 1Mm Thick Laminated Sheet Sqm 3693.0 9.201.2 0.12 Mm Thick Laminated Sheet Sqm 3461.0 182 9.202 9.202.1 35Mm Thick Including 4 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3339.0 9.202.2 35Mm Thick Including 3 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3171.0 9.202.3 25Mm Thick (For Cupboard) Including 3 Nos. 75Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 3005.0 183 9.203 9.203.1 35Mm Thick Including 4 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary. Sqm 1953.0 9.203.2 30Mm Thick Including 3 Nos. 100Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 1772.0 25Mm Thick Including 3 Nos. 100Mm Long, Screws. Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 1532.0 184 9.204 185 9.213 9.213.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 2775.0 9.213.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 2675.0 9.213.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2575.0 186 9.214 9.214.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3650.0 9.214.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws.Screws. Sqm 3550.0 9.214.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 3450.0 187 9.215 9.215.1 35 Mm Thick Including 4 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3121.0 9.215.2 30 Mm Thick Including 3 Nos. 100 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Stainless Steel Butt Hinges With Necessary Screws. Sqm 3021.0 9.215.3 25Mm Thick (For Cupboard) Including 3 Nos. 75 Mm Long, Isi Marked Heavy Weight (2.5Mm Thick) Nickel Plated Bright Finished M.S. Piano Hinges With Necessary Screws. Sqm 2921.0
Contract Date: Jun 24, 2026 Contract Value : 20.40 Lakh
Government Departments No of Bidders 3
Madhya Pradesh View Result →
23.
Public Administrative Department #11029475 AOC
Tender For Supply Of Departmental Fire Vehicle Parts And Job Works , Ashok Leland (Qrv) , Accelerator Paddle , Accelerator Wire , Air Cleaner Rubber , Air Filter Body , Air Pipe , Air Pressure Tank , Altenator , Alternater Bearing , Alternater Cut Out , Alternater Starter , Alternator Assembly , Alternator Body , Amplifier Assembly , Armature , Back Light Complete Set , Bearing Sensor , Benzo Bolt Washer , Block Tikki , Brake Leather Complete Thali , Brake Pad Assembly , Brake Paddle , Brake Pipe , Brake Pipe Big Steel , Brake Pipe Small Steel , Brake Servo Assembly , Brake Shoe Thali , Brake T Big , Brake T Small , Break Cam Shaft , Break Cam Shaft Bush , Break Controller Kit , Break Controller Rear , Break Pad , Break Thali Rear Assembly , Cam Gear , Cam Sensor , Cam Shaft , Cam Tikki , Center Bearing Rubber , Center Bearing Assembly , Center Bearing Jhoola , Center Bolt Front , Center Bolt Rear , Center Glass , Chilam , Chilamjhiri , Chillam Oil Set , Choke Wire , Clutch Bearing Hub , Clutch Fork , Clutch Gear , Clutch Housing , Clutch Housing Bolt , Clutch Paddle , Clutch Plate , Clutch Release Bearing , Clutch Spring , Clutch Washer , Clutch Wire , Common Relay , Commutator , Compressor Connecting Bearing , Compressor Connecting Rod , Compressor Head , Compressor Head Kit , Compressor Pipe , Compressor Piston , Compressor Piston Ring , Connecting Bearing , Connecting Bolt , Connecting Rod Complete , Connecting Switch Assembly , Counter Bearing , Crank , Crown Assembly , Crown Side Bearing , Diesel Filter , Diesel Filter Body , Diesel Filter Main Pipe , Diesel Main Pipe , Diesel Return Pipe , Diesel Tank , Diesel Tank Cap , Diesel Tank Clamp , Diesel Tank Motor Assembly , Diode Plate , Door Gate Complete Set , Door Gate Machine , Door Lock Complete Set , Driver Seat Assembly , Engine Packing Set , Exhaust Manifold , Fan Belt , Finger Kit , Flanges Oil Seal Set , Flywheel , Flywheel Bolt , Flywheel Gear Ring , Front Break Controller Set , Front Hub , Front Hub Bearing , Front Kamani , Fuel Sensor , Gate Gatta Set , Gate Glass , Gate Glass Machine , Gear Box Assembly , Gear Box Housing , Gear Box Tapa Bolt , Gear Box Tumbler , Gear Changer , Gear Fork Kit , Gear Fork No 1 , Gear Fork No. 2 , Gear Fork No. 3 , Gear Lever , Gear Lever Bearing , Gear Lever End , Gear Lever Rod , Gear No. 1 , Gear No. 2 , Gear No. 3 , Gear No. 4 , Gear No. 5 , Gear Packing Set , Half Yoke Flanges , Hand Break , Head Assembly , Head Fuel Box , Head Gas Kit , Head Light , Head Light Cut Out , Head Light Switch , Head Stud And Nut , Head Tikki , Horn Cut Out , Hose Pipe , Hose Pipe Clamp , Housing Tube , Hub Bearing 32213 , Hub Bearing 32214 , Hub Bearing 32216 , Hub Bearing 32219 , Hub Bearing Big , Hub Bearing Small , Hub Oil Seal , Hub Stud , Idler Gear , Iiner , Indicator Light , Kamaani Helper Patta 2 , Kaman Mukki Nut Bolt , Kamani Bush , Kamani Clamp 4 Inch , Kamani Clamp 6 Inch , Kamani Helper Patta 1 , Kamani Helper Patta 3 , Kamani Jhoola , Kamani Leaf 2Nd , Kamani Leaf 3Rd , Kamani Leaf 4 Th , Kamani Main Pata , Kamani Mukki , Kamani Patta New , Kamani Pin , Kamani Side Washer , Kin Pin Kit , Kinpin Pin , Lifter , Main Bearing , Main Oil Seal , Main Shaft , Main Shaft Bearing , Master Cylinder , Master Cylinder Kit , Meter Dashboard Set , Milometer Chain , Milometer Plate , Nozzle , Nozzle Pipe , Nozzle Pipe Set , Oil Chamber , Oil Filter , Oil Filter Body , Oil Meter , Oil Pipe , Oil Pipe Kit , Oil Pump , Parking Light , Piston , Piston Ring , Plate Packet For Chassis , Pressure Horn Set , Pressure Meter , Pressure Pipe , Pressure Pipe Rubber Set , Pressure Pipe Steel , Pressure Plate , Pressure Plate Leather , Pressure Tank , Pressure Tank Clamp , Pressure Tank Valve , Pressure Valve (Fnduh) Assembly , Pressure Valve (Fnduh) Filter/ Yhysam Nkslr + , Pressure Valve (Fnduh) Kit , Priming Box Bearing , Priming Valve Kit , Propeller Shaft , Pto Cross , Pull/Push Switch , Pump Assembly , Pump Gear , Pump Packing Sheet , Pump Switch , Push Rod Complete , Radiator Bottom , Radiator Fan , Radiator Nest , Reaper Axle , Reaper Gear , Reaper Hub , Rear Controller Set , Rear Gear , Rear Hub , Relay Cut Out , Rocker Plate , Sancronizer , Self Armature , Self Assembly , Self Bearing , Self Bendix , Self Bush Set , Self Carbon , Self Chemta , Self Dieboard Plate , Self Field , Self Housing , Self Solenoid Switch , Self Spoke , Self Starter , Self Starter Switch , Shaft , Shaft Yoke , Show Main Glass , Show Taapa Set , Silencer Assembly , Silencer Muffler , Silencer Pipe , Spindle , Spindle Bush Set , Spindle Shaft , Starting Switch , Steering Arm , Steering Box Assembly , Steering Bush Assembly , Steering Cross , Steering Oil Seal Rubber Kit , Steering Pipe , Steering Pipe With Clamp , Steering Rod , Steering Rod Bolt Nut , Steering Sector Shaft , Steering Wheel , Tail Pinion , Tail Pinion Bearing , Tail Pinion Cut Bearing , Tail Pinion Flanges , Tail Pinion Seal , Tappet Cover Assembly , Temperature Meter , Temperature Switch , Temperature T , Terminal Lug , Terminal Wire , Thrust Bearing , Tie Rod Complete , Tie Rod End , Tie Rod Varne , Timing Gear , Timing Oil Seal , Timing Plate , Top Pinion Bearing , Top Pinion Gear , Tt Horn , Turbo Hose Pipe , U Bolt Front , U Bolt Rear , Uj Cross , Valve Bowl Set , Valve Cutter Set , Valve Guide Set , Valve Spring , Vowel Star Set , Wheel Cylinder Assembly , Wheel Cylinder Washer , Wiper Arm , Wiper Assembly , Wiper Blade , Wiper Key Switch Assembly , Wiper Machine , Wiper Opening , Wiper Qoil , Wiper Rod , Tata 709/710 /Yhysam Ikvzuj , Accelerator Paddle , Accelerator Wire , Air Cleaner Rubber , Air Filter Body , Air Pipe , Air Pressure Tank , Altenator , Alternater Bearing , Alternater Cut Out , Alternater Starter , Alternator Assembly , Alternator Body , Amplifier Assembly , Armature , Back Light Complete Set , Bearing Sensor , Benzo Bolt Washer , Block Tikki , Brake Leather Complete Thali , Brake Pad Assembly , Brake Paddle , Brake Pipe , Brake Pipe Big Steel , Brake Pipe Small Steel , Brake Servo Assembly , Brake Shoe Thali , Brake T Big , Brake T Small , Break Cam Shaft , Break Cam Shaft Bush , Break Controller Kit , Break Controller Rear , Break Pad , Break Thali Rear Assembly , Cam Gear , Cam Sensor , Cam Shaft , Cam Tikki , Center Bearing Rubber , Center Bearing Assembly , Center Bearing Jhoola , Center Bolt Front , Center Bolt Rear , Center Glass , Chilam , Chilamjhiri , Chillam Oil Set , Choke Wire , Clutch Bearing Hub , Clutch Fork , Clutch Gear , Clutch Housing , Clutch Housing Bolt , Clutch Paddle , Clutch Plate , Clutch Release Bearing , Clutch Spring , Clutch Washer , Clutch Wire , Common Relay , Commutator , Compressor Connecting Bearing , Compressor Connecting Rod , Compressor Head , Compressor Head Kit , Compressor Pipe , Compressor Piston , Compressor Piston Ring , Connecting Bearing , Connecting Bolt , Connecting Rod Complete , Connecting Switch Assembly , Counter Bearing , Crank , Crown Assembly , Crown Side Bearing , Diesel Filter , Diesel Filter Body , Diesel Filter Main Pipe , Diesel Main Pipe , Diesel Return Pipe , Diesel Tank , Diesel Tank Cap , Diesel Tank Clamp , Diesel Tank Motor Assembly , Diode Plate , Door Gate Complete Set , Door Gate Machine , Door Lock Complete Set , Driver Seat Assembly , Engine Packing Set , Exhaust Manifold , Fan Belt , Finger Kit , Flanges Oil Seal Set , Flywheel , Flywheel Bolt , Flywheel Gear Ring , Front Break Controller Set , Front Hub , Front Hub Bearing , Front Kamani , Fuel Sensor , Gate Gatta Set , Gate Glass , Gate Glass Machine , Gear Box Assembly , Gear Box Housing , Gear Box Tapa Bolt , Gear Box Tumbler , Gear Changer , Gear Fork Kit , Gear Fork No 1 , Gear Fork No. 2 , Gear Fork No. 3 , Gear Lever , Gear Lever Bearing , Gear Lever End , Gear Lever Rod , Gear No. 1 , Gear No. 2 , Gear No. 3 , Gear No. 4 , Gear No. 5 , Gear Packing Set , Half Yoke Flanges , Head Assembly , Head Fuel Box , Head Gas Kit , Head Light , Head Light Cut Out , Head Light Switch , Head Stud And Nut , Head Tikki , Horn Cut Out , Hose Pipe , Hose Pipe Clamp , Housing Tube , Hub Bearing 32213 , Hub Bearing 32214 , Hub Bearing 32216 , Hub Bearing 32219 , Hub Bearing Big , Hub Bearing Small , Hub Oil Seal , Hub Stud , Idler Gear , Iiner , Indicator Light , Kamaani Helper Patta 2 , Kaman Mukki Nut Bolt , Kamani Bush , Kamani Clamp 4 Inch , Kamani Clamp 6 Inch , Kamani Helper Patta 1 , Kamani Helper Patta 3 , Kamani Jhoola , Kamani Leaf 2Nd , Kamani Leaf 3Rd , Kamani Leaf 4 Th , Kamani Main Pata , Kamani Mukki , Kamani Patta New , Kamani Pin , Kamani Side Washer , Kin Pin Kit , Kinpin Pin , Lifter , Main Bearing , Main Oil Seal , Main Shaft , Main Shaft Bearing , Master Cylinder , Master Cylinder Kit , Meter Dashboard Set , Milometer Chain , Milometer Plate , Nozzle , Nozzle Pipe , Nozzle Pipe Set , Oil Chamber , Oil Filter , Oil Filter Body , Oil Meter , Oil Pipe , Oil Pipe Kit , Oil Pump , Parking Light , Piston , Piston Ring , Plate Packet For Chassis , Propeller Shaft , Pressure Horn Set , Pressure Meter , Pressure Pipe , Pressure Pipe Rubber Set , Pressure Pipe Steel , Pressure Plate , Pressure Plate Leather , Pressure Tank , Pressure Tank Clamp , Pressure Tank Valve , Pressure Valve (Fnduh) Assembly , Pressure Valve (Fnduh) Filter , Pressure Valve (Fnduh) Kit , Priming Box Bearing , Priming Valve Kit , Pto Cross , Pull/Push Switch , Pump Assembly , Pump Gear , Pump Packing Sheet , Pump Switch , Push Rod Complete , Radiator Bottom , Radiator Fan , Radiator Nest , Reaper Axle , Reaper Gear , Reaper Hub , Rear Controller Set , Rear Gear , Rear Hub , Relay Cut Out , Rocker Plate , Sancronizer , Self Armature , Self Assembly , Self Bearing , Self Bendix , Self Bush Set , Self Carbon , Self Chemta , Self Dieboard Plate , Self Field , Self Housing , Self Solenoid Switch , Self Spoke , Self Starter , Self Starter Switch , Shaft Yoke , Show Main Glass , Show Taapa Set , Silencer Assembly , Silencer Muffler , Silencer Pipe , Spindle , Spindle Bush Set , Spindle Shaft , Starting Switch , Steering Arm , Steering Box Assembly , Steering Bush Assembly , Steering Cross , Steering Oil Seal Rubber Kit , Steering Pipe , Steering Pipe With Clamp , Steering Rod , Steering Rod Bolt Nut , Steering Sector Shaft , Steering Wheel , Tail Pinion , Tail Pinion Bearing , Tail Pinion Cut Bearing , Tail Pinion Flanges , Tail Pinion Seal , Tappet Cover Assembly , Temperature Meter , Temperature Switch , Temperature T , Terminal Lug , Terminal Wire , Thrust Bearing , Tie Rod Complete , Tie Rod End , Tie Rod Varne , Timing Gear , Timing Oil Seal , Timing Plate , Top Pinion Bearing , Top Pinion Gear , Tt Horn , Turbo Hose Pipe , U Bolt Front , U Bolt Rear , Uj Cross , Valve Bowl Set , Valve Cutter Set , Valve Guide Set , Valve Spring , Vowel Star Set , Wheel Cylinder Assembly , Wheel Cylinder Washer , Wiper Arm , Wiper Assembly , Wiper Blade , Wiper Key Switch Assembly , Wiper Machine , Wiper Opening , Wiper Qoil Repairing , Wiper Rod , Hand Break , Shaft , Tata 1210 , Accelerator Paddle , Accelerator Wire , Air Cleaner Rubber , Air Filter Body , Air Pipe , Air Pressure Tank , Altenator , Alternater Bearing , Alternater Cut Out , Alternater Starter , Alternator Assembly , Alternator Body , Amplifier Assembly , Armature , Back Light Complete Set , Bearing Sensor , Benzo Bolt Washer , Block Tikki , Brake Leather Complete Thali , Brake Pad Assembly , Brake Paddle , Brake Pipe , Brake Pipe Big Steel , Brake Pipe Small Steel , Brake Servo Assembly , Brake Shoe Thali , Brake T Big , Brake T Small , Break Cam Shaft , Break Cam Shaft Bush , Break Controller Kit , Break Controller Rear , Break Pad , Break Thali Rear Assembly , Cam Gear , Cam Sensor , Cam Shaft , Cam Tikki , Center Bearing Rubber , Center Bearing Assembly , Center Bearing Jhoola , Center Bolt Front , Center Bolt Rear , Center Glass , Chilam , Chilamjhiri , Chillam Oil Set , Choke Wire , Clutch Bearing Hub , Clutch Fork , Clutch Gear , Clutch Housing , Clutch Housing Bolt , Clutch Paddle , Clutch Plate , Clutch Release Bearing , Clutch Spring , Clutch Washer , Clutch Wire , Common Relay , Commutator , Compressor Connecting Bearing , Compressor Connecting Rod , Compressor Head , Compressor Head Kit , Compressor Pipe , Compressor Piston , Compressor Piston Ring , Connecting Bearing , Connecting Bolt , Connecting Rod Complete , Connecting Switch Assembly , Counter Bearing , Crank , Crown Assembly , Crown Side Bearing , Diesel Filter , Diesel Filter Body , Diesel Filter Main Pipe , Diesel Main Pipe , Diesel Return Pipe , Diesel Tank , Diesel Tank Cap , Diesel Tank Clamp , Diesel Tank Motor Assembly , Diode Plate , Door Gate Complete Set , Door Gate Machine , Door Lock Complete Set , Driver Seat Assembly , Engine Packing Set , Exhaust Manifold , Fan Belt , Finger Kit , Flanges Oil Seal Set , Flywheel , Flywheel Bolt , Flywheel Gear Ring , Front Break Controller Set , Front Hub , Front Hub Bearing , Front Kamani , Fuel Sensor , Gate Gatta Set , Gate Glass , Gate Glass Machine , Gear Box Assembly , Gear Box Housing , Gear Box Tapa Bolt , Gear Box Tumbler , Gear Changer , Gear Fork Kit , Gear Fork No 1 , Gear Fork No. 2 , Gear Fork No. 3 , Gear Lever , Gear Lever Bearing , Gear Lever End , Gear Lever Rod , Gear No. 1 , Gear No. 2 , Gear No. 3 , Gear No. 4 , Gear No. 5 , Gear Packing Set , Half Yoke Flanges , Head Assembly , Head Fuel Box , Head Gas Kit , Head Light , Head Light Cut Out , Head Light Switch , Head Stud And Nut , Head Tikki , Horn Cut Out , Hose Pipe , Hose Pipe Clamp , Housing Tube , Hub Bearing 32213 , Hub Bearing 32214 , Hub Bearing 32216 , Hub Bearing 32219 , Hub Bearing Big , Hub Bearing Small , Hub Oil Seal , Hub Stud , Idler Gear , Iiner , Indicator Light , Kamaani Helper Patta 2 , Kaman Mukki Nut Bolt , Kamani Bush , Kamani Clamp 4 Inch , Kamani Clamp 6 Inch , Kamani Helper Patta 1 , Kamani Helper Patta 3 , Kamani Jhoola , Kamani Leaf 2Nd , Kamani Leaf 3Rd , Kamani Leaf 4 Th , Kamani Main Pata , Kamani Mukki , Kamani Patta New , Kamani Pin , Kamani Side Washer , Kin Pin Kit , Kinpin Pin , Lifter , Main Bearing , Main Oil Seal , Main Shaft , Main Shaft Bearing , Master Cylinder , Master Cylinder Kit , Meter Dashboard Set , Milometer Chain , Milometer Plate , Nozzle , Nozzle Pipe , Nozzle Pipe Set , Oil Chamber , Oil Filter , Oil Filter Body , Oil Meter , Oil Pipe , Oil Pipe Kit , Oil Pump , Parking Light , Piston , Piston Ring , Plate Packet For Chassis , Propeller Shaft , Pressure Horn Set , Pressure Meter , Pressure Pipe , Pressure Pipe Rubber Set , Pressure Pipe Steel , Pressure Plate , Pressure Plate Leather , Pressure Tank , Pressure Tank Clamp , Pressure Tank Valve , Pressure Valve (Fnduh) Assembly , Pressure Valve (Fnduh) Filter , Pressure Valve (Fnduh) Kit , Priming Box Bearing , Priming Valve Kit , Pto Cross , Pull/Push Switch , Pump Assembly , Pump Gear , Pump Packing Sheet , Pump Switch , Push Rod Complete , Radiator Bottom , Radiator Fan , Radiator Nest , Reaper Axle , Reaper Gear , Reaper Hub , Rear Controller Set , Rear Gear , Rear Hub , Relay Cut Out , Rocker Plate , Sancronizer , Self Armature , Self Assembly , Self Bearing , Self Bendix , Self Bush Set , Self Carbon , Self Chemta , Self Dieboard Plate , Self Field , Self Housing , Self Solenoid Switch , Self Spoke , Self Starter , Self Starter Switch , Shaft Yoke , Show Main Glass , Show Taapa Set , Silencer Assembly , Silencer Muffler , Silencer Pipe , Spindle , Spindle Bush Set , Spindle Shaft , Starting Switch , Steering Arm , Steering Box Assembly , Steering Bush Assembly , Steering Cross , Steering Oil Seal Rubber Kit , Steering Pipe , Steering Pipe With Clamp , Steering Rod , Steering Rod Bolt Nut , Steering Sector Shaft , Steering Wheel , Tail Pinion , Tail Pinion Bearing , Tail Pinion Cut Bearing , Tail Pinion Flanges , Tail Pinion Seal , Tappet Cover Assembly , Temperature Meter , Temperature Switch , Temperature T , Terminal Lug , Terminal Wire , Thrust Bearing , Tie Rod Complete , Tie Rod End , Tie Rod Varne , Timing Gear , Timing Oil Seal , Timing Plate , Top Pinion Bearing , Top Pinion Gear , Tt Horn , Turbo Hose Pipe , U Bolt Front , U Bolt Rear , Uj Cross , Valve Bowl Set , Valve Cutter Set , Valve Guide Set , Valve Spring , Vowel Star Set , Wheel Cylinder Assembly , Wheel Cylinder Washer , Wiper Arm , Wiper Assembly , Wiper Blade , Wiper Key Switch Assembly , Wiper Machine , Wiper Opening , Wiper Qoil Repairing , Wiper Rod , Hand Break , Shaft , Tata 1613 , Accelerator Paddle , Accelerator Wire , Air Cleaner Rubber , Air Filter Body , Air Pipe , Air Pressure Tank , Altenator , Alternater Bearing , Alternater Cut Out , Alternater Starter , Alternator Assembly , Alternator Body , Amplifier Assembly , Armature , Back Light Complete Set , Bearing Sensor , Benzo Bolt Washer , Block Tikki , Brake Leather Complete Thali , Brake Pad Assembly , Brake Paddle , Brake Pipe , Brake Pipe Big Steel , Brake Pipe Small Steel , Brake Servo Assembly , Brake Shoe Thali , Brake T Big , Brake T Small , Break Cam Shaft , Break Cam Shaft Bush , Break Controller Kit , Break Controller Rear , Break Pad , Break Thali Rear Assembly , Cam Gear , Cam Sensor , Cam Shaft , Cam Tikki , Center Bearing Rubber , Center Bearing Assembly , Center Bearing Jhoola , Center Bolt Front , Center Bolt Rear , Center Glass , Chilam , Chilamjhiri , Chillam Oil Set , Choke Wire , Clutch Bearing Hub , Clutch Fork , Clutch Gear , Clutch Housing , Clutch Housing Bolt , Clutch Paddle , Clutch Plate , Clutch Release Bearing , Clutch Spring , Clutch Washer , Clutch Wire , Common Relay , Commutator , Compressor Connecting Bearing , Compressor Connecting Rod , Compressor Head , Compressor Head Kit , Compressor Pipe , Compressor Piston , Compressor Piston Ring , Connecting Bearing , Connecting Bolt , Connecting Rod Complete , Connecting Switch Assembly , Counter Bearing , Crank , Crown Assembly , Crown Side Bearing , Diesel Filter , Diesel Filter Body , Diesel Filter Main Pipe , Diesel Main Pipe , Diesel Return Pipe , Diesel Tank , Diesel Tank Cap , Diesel Tank Clamp , Diesel Tank Motor Assembly , Diode Plate , Door Gate Complete Set , Door Gate Machine , Door Lock Complete Set , Driver Seat Assembly , Engine Packing Set , Exhaust Manifold , Fan Belt , Finger Kit , Flanges Oil Seal Set , Flywheel , Flywheel Bolt , Flywheel Gear Ring , Front Break Controller Set , Front Hub , Front Hub Bearing , Front Kamani , Fuel Sensor , Gate Gatta Set , Gate Glass , Gate Glass Machine , Gear Box Assembly , Gear Box Housing , Gear Box Tapa Bolt , Gear Box Tumbler , Gear Changer , Gear Fork Kit , Gear Fork No 1 , Gear Fork No. 2 , Gear Fork No. 3 , Gear Lever , Gear Lever Bearing , Gear Lever End , Gear Lever Rod , Gear No. 1 , Gear No. 2 , Gear No. 3 , Gear No. 4 , Gear No. 5 , Gear Packing Set , Half Yoke Flanges , Head Assembly , Head Fuel Box , Head Gas Kit , Head Light , Head Light Cut Out , Head Light Switch , Head Stud And Nut , Head Tikki , Horn Cut Out , Hose Pipe , Hose Pipe Clamp , Housing Tube , Hub Bearing 32213 , Hub Bearing 32214 , Hub Bearing 32216 , Hub Bearing 32219 , Hub Bearing Big , Hub Bearing Small , Hub Oil Seal , Hub Stud , Idler Gear , Iiner , Indicator Light , Kamaani Helper Patta 2 , Kaman Mukki Nut Bolt , Kamani Bush , Kamani Clamp 4 Inch , Kamani Clamp 6 Inch , Kamani Helper Patta 1 , Kamani Helper Patta 3 , Kamani Jhoola , Kamani Leaf 2Nd , Kamani Leaf 3Rd , Kamani Leaf 4 Th , Kamani Main Pata , Kamani Mukki , Kamani Patta New , Kamani Pin , Kamani Side Washer , Kin Pin Kit , Kinpin Pin , Lifter , Main Bearing , Main Oil Seal , Main Shaft , Main Shaft Bearing , Master Cylinder , Master Cylinder Kit , Meter Dashboard Set , Milometer Chain , Milometer Plate , Nozzle , Nozzle Pipe , Nozzle Pipe Set , Oil Chamber , Oil Filter , Oil Filter Body , Oil Meter , Oil Pipe , Oil Pipe Kit , Oil Pump , Parking Light , Piston , Piston Ring , Plate Packet For Chassis , Propeller Shaft , Pressure Horn Set , Pressure Meter , Pressure Pipe , Pressure Pipe Rubber Set , Pressure Pipe Steel , Pressure Plate , Pressure Plate Leather , Pressure Tank , Pressure Tank Clamp , Pressure Tank Valve , Pressure Valve (Fnduh) Assembly , Pressure Valve (Fnduh) Filter , Pressure Valve (Fnduh) Kit , Priming Box Bearing , Priming Valve Kit , Pto Cross , Pull/Push Switch , Pump Assembly , Pump Gear , Pump Packing Sheet , Pump Switch , Push Rod Complete , Radiator Bottom , Radiator Fan , Radiator Nest , Reaper Axle , Reaper Gear , Reaper Hub , Rear Controller Set , Rear Gear , Rear Hub , Relay Cut Out , Rocker Plate , Sancronizer , Self Armature , Self Assembly , Self Bearing , Self Bendix , Self Bush Set , Self Carbon , Self Chemta , Self Dieboard Plate , Self Field , Self Housing , Self Solenoid Switch , Self Spoke , Self Starter , Self Starter Switch , Shaft Yoke , Show Main Glass , Show Taapa Set , Silencer Assembly , Silencer Muffler , Silencer Pipe , Spindle , Spindle Bush Set , Spindle Shaft , Starting Switch , Steering Arm , Steering Box Assembly , Steering Bush Assembly , Steering Cross , Steering Oil Seal Rubber Kit , Steering Pipe , Steering Pipe With Clamp , Steering Rod , Steering Rod Bolt Nut , Steering Sector Shaft , Steering Wheel , Tail Pinion , Tail Pinion Bearing , Tail Pinion Cut Bearing , Tail Pinion Flanges , Tail Pinion Seal , Tappet Cover Assembly , Temperature Meter , Temperature Switch , Temperature T , Terminal Lug , Terminal Wire , Thrust Bearing , Tie Rod Complete , Tie Rod End , Tie Rod Varne , Timing Gear , Timing Oil Seal , Timing Plate , Top Pinion Bearing , Top Pinion Gear , Tt Horn , Turbo Hose Pipe , U Bolt Front , U Bolt Rear , Uj Cross , Valve Bowl Set , Valve Cutter Set , Valve Guide Set , Valve Spring , Vowel Star Set , Wheel Cylinder Assembly , Wheel Cylinder Washer , Wiper Arm , Wiper Assembly , Wiper Blade , Wiper Key Switch Assembly , Wiper Machine , Wiper Opening , Wiper Qoil Repairing , Wiper Rod , Hand Break , Shaft , Leyland 1616/1615 , Accelerator Paddle , Accelerator Wire , Air Cleaner Rubber , Air Filter Body , Air Pipe , Air Pressure Tank , Altenator , Alternater Bearing , Alternater Cut Out , Alternater Starter , Alternator Assembly , Alternator Body , Amplifier Assembly , Armature , Back Light Complete Set , Bearing Sensor , Benzo Bolt Washer , Block Tikki , Brake Leather Complete Thali , Brake Pad Assembly , Brake Paddle , Brake Pipe , Brake Pipe Big Steel , Brake Pipe Small Steel , Brake Servo Assembly , Brake Shoe Thali , Brake T Big , Brake T Small , Break Cam Shaft , Break Cam Shaft Bush , Break Controller Kit , Break Controller Rear , Break Pad , Break Thali Rear Assembly , Cam Gear , Cam Sensor , Cam Shaft , Cam Tikki , Center Bearing Rubber , Center Bearing Assembly , Center Bearing Jhoola , Center Bolt Front , Center Bolt Rear , Center Glass , Chilam , Chilamjhiri , Chillam Oil Set , Choke Wire , Clutch Bearing Hub , Clutch Fork , Clutch Gear , Clutch Housing , Clutch Housing Bolt , Clutch Paddle , Clutch Plate , Clutch Release Bearing , Clutch Spring , Clutch Washer , Clutch Wire , Common Relay , Commutator , Compressor Connecting Bearing , Compressor Connecting Rod , Compressor Head , Compressor Head Kit , Compressor Pipe , Compressor Piston , Compressor Piston Ring , Connecting Bearing , Connecting Bolt , Connecting Rod Complete , Connecting Switch Assembly , Counter Bearing , Crank , Crown Assembly , Crown Side Bearing , Diesel Filter , Diesel Filter Body , Diesel Filter Main Pipe , Diesel Main Pipe , Diesel Return Pipe , Diesel Tank , Diesel Tank Cap , Diesel Tank Clamp , Diesel Tank Motor Assembly , Diode Plate , Door Gate Complete Set , Door Gate Machine , Door Lock Complete Set , Driver Seat Assembly , Engine Packing Set , Exhaust Manifold , Fan Belt , Finger Kit , Flanges Oil Seal Set , Flywheel , Flywheel Bolt , Flywheel Gear Ring , Front Break Controller Set , Front Hub , Front Hub Bearing , Front Kamani , Fuel Sensor , Gate Gatta Set , Gate Glass , Gate Glass Machine , Gear Box Assembly , Gear Box Housing , Gear Box Tapa Bolt , Gear Box Tumbler , Gear Changer , Gear Fork Kit , Gear Fork No 1 , Gear Fork No. 2 , Gear Fork No. 3 , Gear Lever , Gear Lever Bearing , Gear Lever End , Gear Lever Rod , Gear No. 1 , Gear No. 2 , Gear No. 3 , Gear No. 4 , Gear No. 5 , Gear Packing Set , Half Yoke Flanges , Head Assembly , Head Fuel Box , Head Gas Kit , Head Light , Head Light Cut Out , Head Light Switch , Head Stud And Nut , Head Tikki , Horn Cut Out , Hose Pipe , Hose Pipe Clamp , Housing Tube , Hub Bearing 32213 , Hub Bearing 32214 , Hub Bearing 32216 , Hub Bearing 32219 , Hub Bearing Big , Hub Bearing Small , Hub Oil Seal , Hub Stud , Idler Gear , Iiner , Indicator Light , Kamaani Helper Patta 2 , Kaman Mukki Nut Bolt , Kamani Bush , Kamani Clamp 4 Inch , Kamani Clamp 6 Inch , Kamani Helper Patta 1 , Kamani Helper Patta 3 , Kamani Jhoola , Kamani Leaf 2Nd , Kamani Leaf 3Rd , Kamani Leaf 4 Th , Kamani Main Pata , Kamani Mukki , Kamani Patta New , Kamani Pin , Kamani Side Washer , Kin Pin Kit , Kinpin Pin , Lifter , Main Bearing , Main Oil Seal , Main Shaft , Main Shaft Bearing , Master Cylinder , Master Cylinder Kit , Meter Dashboard Set , Milometer Chain , Milometer Plate , Nozzle , Nozzle Pipe , Nozzle Pipe Set , Oil Chamber , Oil Filter , Oil Filter Body , Oil Meter , Oil Pipe , Oil Pipe Kit , Oil Pump , Parking Light , Piston , Piston Ring , Plate Packet For Chassis , Propeller Shaft , Pressure Horn Set , Pressure Meter , Pressure Pipe , Pressure Pipe Rubber Set , Pressure Pipe Steel , Pressure Plate , Pressure Plate Leather , Pressure Tank , Pressure Tank Clamp , Pressure Tank Valve , Pressure Valve (Fnduh) Assembly , Pressure Valve (Fnduh) Filter , Pressure Valve (Fnduh) Kit , Priming Box Bearing , Priming Valve Kit , Pto Cross , Pull/Push Switch , Pump Assembly , Pump Gear , Pump Packing Sheet , Pump Switch , Push Rod Complete , Radiator Bottom , Radiator Fan , Radiator Nest , Reaper Axle , Reaper Gear , Reaper Hub , Rear Controller Set , Rear Gear , Rear Hub , Relay Cut Out , Rocker Plate , Sancronizer , Self Armature , Self Assembly , Self Bearing , Self Bendix , Self Bush Set , Self Carbon , Self Chemta , Self Dieboard Plate , Self Field , Self Housing , Self Solenoid Switch , Self Spoke , Self Starter , Self Starter Switch , Shaft Yoke , Show Main Glass , Show Taapa Set , Silencer Assembly , Silencer Muffler , Silencer Pipe , Spindle , Spindle Bush Set , Spindle Shaft , Starting Switch , Steering Arm , Steering Box Assembly , Steering Bush Assembly , Steering Cross , Steering Oil Seal Rubber Kit , Steering Pipe , Steering Pipe With Clamp , Steering Rod , Steering Rod Bolt Nut , Steering Sector Shaft , Steering Wheel , Tail Pinion , Tail Pinion Bearing , Tail Pinion Cut Bearing , Tail Pinion Flanges , Tail Pinion Seal , Tappet Cover Assembly , Temperature Meter , Temperature Switch , Temperature T , Terminal Lug , Terminal Wire , Thrust Bearing , Tie Rod Complete , Tie Rod End , Tie Rod Varne , Timing Gear , Timing Oil Seal , Timing Plate , Top Pinion Bearing , Top Pinion Gear , Tt Horn , Turbo Hose Pipe , U Bolt Front , U Bolt Rear , Uj Cross , Valve Bowl Set , Valve Cutter Set , Valve Guide Set , Valve Spring , Vowel Star Set , Wheel Cylinder Assembly , Wheel Cylinder Washer , Wiper Arm , Wiper Assembly , Wiper Blade , Wiper Key Switch Assembly , Wiper Machine , Wiper Opening , Wiper Qoil Repairing , Wiper Rod , Hand Break , Shaft , Equipment/Work/Services , Annual Rate Contract Welding Machine 250Amp , Welding Rod Brass 10No. 100Gm , Aluminium Angle 25Mmx3Mm , Aluminium Angle 32Mmx3Mm , Aluminium Beat 1.5 Inchx16Gauge , Aluminium Beat 2 Inchx16Gauge , Aluminium Plate , Lathe Machine Admit Between Centres 18 Inch, 2Hp, 8 Feet , Angle Ms , Bench Vice Fix Base 150Mm , Beacon Light (12V, 36W) , Bearing 6204 , Bearing 6207 , Bearing 6208 N , Bearing 6214 , Bearing 6255 N , Engine Crane With Stand (2 Ton) , Pipe Vice 150Mm , Aluminium Welding Rod 10No. 1Oo Gm , Brass Bolt 100Gm , Brass Washer 100Gm , Butterfly Valve 1 , Butterfly Valve 3 , Butterfly Valve 4 , Cabin Light (12V, 35 W) , Conduite Pipe Ms , Cr Plate , Cushion (3 Inch) , Flex Head Ratchet ½ Inch , Channel Ms , Chequered Plate Aluminium , Air Ratchet Wrench (Pneumatic)1/2 Inch , Fire Pump O Ring (2250 Lpm) , Fire Pump O Ring (1800 Lpm) , Fire Pump Oil Seal ¼2250 Lpm½ , Fire Pump Shaft (1800 Lpm) Gm , Fire Pump Shaft (2250 Lpm) Gm , Fire Pump Shaft Bearing Long (1800 Lpm) , Fire Pump Shaft Bearing Long (2250 Lpm) , Fire Pump Shaft Bearing Small (1800 Lpm) , Fire Pump Shaft Bearing Small (2250 Lpm) , Fire Pump Oil Seal 1800 Lpm , Bent Handle Flex Ratchet ½ Inch , Electric Wire Copper 3Mm , Electric Wire Copper 4Mm , Electric Wire Copper 5Mm , Exide/Amaron/Equivalent Battery 100 Ah , Exide/Amaron/Equivalent Battery 150Ah , Exide/Amaron/Equivalent Battery 70Ah , Exide/Amaron/Equivalent Battery 80Ah , Electric Operated Siren 1Km Range , Hood Light For Car/Vehicle Repair 15W Rechargeable , Fire Pump (1800 Lpm Gunmetal) , Fire Pump (2250 Lpm Gunmetal) , Fire Pump Ampeller (1800 Lpm Gunmetal) , Fire Pump Ampeller (2250 Lpm Gunmetal) , Fire Pump Bush Set (1800 Lpm) , Fire Pump Bush Set (2250 Lpm) , Fire Pump Carbon Seal (2250 Lpm) , Fire Pump Carbon Seal ¼1800 Lpm½ , Fire Pump Carter Seal (1800 Lpm) , Fire Pump Carter Seal (2250 Lpm) , Gi Pipe , Gi Wire 4Mm 100Gm , Hinge Hinge (Brass) 3(Heavy Duty) , Hinge Hinge (Brass) 4(Heavy Duty) , Hinge Hinge (Steel) 3(Heavy Duty) , Hinge Hinge (Steel) 4(Heavy Duty) , Hinge Hinge (Brass) 2(Heavy Duty) , Hinge Hinge (Steel) 2(Heavy Duty) , Iron Plate , Lock Handle Set (Aluminium)(Heavy Duty) , Lock Handle Set (Brass)(Heavy Duty) , Male Female Rubber Washer 63 Mm , Ms Bolt 100 Gm , Ms Pipe , Ms Plate , Ms U Bolt , Ms Washer 100Gm , P.T.O. Gear For 1800 Lpm Pump (Gunmetal) , P.T.O. Gear For 2200 Lpm Pump (Gunmetal) , Pa Amplifier 30W , T Socket T Spanner (7Mm To 14Mm) Complete Set , Hexagonal Universal Wrench , Multimeter Digital , Synthetic Automotive Paint , Ply Water Proof (12 Mm) (Heavy Duty) , Conduit Pipe Ss 304 , Rim 8.50-16 , Rim 165-D12 , Rim 7.00-R16 , Red Oxide Primer , Relay 12V 10Amp. , Relay 12V 15Amp. , Rexine (4 Mm) , Rim 10.00-20 , Rim 9.00-20 , Rim 7.25-R16 , Angle Ss 304 , Rust Remover 100Ml , Sand Paper 100 No. 20Cmx5Cmx20Cm , Sand Paper 80 No. 20Cmx5Cmx20Cm , Channel Ss 304 , Wired Speaker 15W , Nose Plier All Types Complete Set , Side Mirror (Tata 207/709/1613/ Leyland 1616) , Silicone Sealant 100G , Socket Wrench Complete Set No. 10 To No. 46 , Metal Tool Box 46Cm X2Ocm X20Cm , Gear Box Jack 20Mm , Clear Coat 2K , Epoxy Hardner , Steel Bolt 1Oogm , Steel Plate 304 , Steel Plate 316 , Steel Washer 100Gm , Steel Welding Rod No. 10 100Gm , Steel Welding Rod No. 8 100Gm , Oil Paint , Thinner , Stud Bolt Ms 27 Mm , Stud Bolt Ms 32 Mm , Thermocol Sheet (1) , Tin Plate , Tube 10.00-20 , Tube 165D12 , Tube 7.00-R16 , Tube 7.25.16 , Tube 8.50.16 , Tube 9.00-20 , Tyre 7.00-R16 , Tyre 8. 50.16 , Tyre 10.00-20 , Tyre 165D12 , Tyre 7.25.16 , Tyre 9.00-20 , Epoxy Primer , Vehicle Bulb (12 V) , Vehicle Bulb (24 V) , Pu Sealant Gun , Vehicle Wire 4Mm , Vehicle Wire 5Mm , Vehicle Wire 8Mm , Blinker Light 12W , Epoxy Paint , Epoxy Thinner , Pu Paint , 4 Way Wheel Wrench All Types Complete Set , 4 Feet Drill Machine With 1 Hp Motor , Window Fiber Glass 5Mm , Thermocol Sheet 50Mm , Sponge 100Mm , Khkk Jcm 0-75 Bap , Qzse Khkk , Lhy ¼52½ , Lhy ¼72½ , Lhy ¼10½ , Csfjax ¼3208½ , Csfjax ¼3209½ , Qkwdz Jkm+ , Qkwdz , Carpage , Eklvj Csfjax , ,Ukeksym Isfdax , Psd Uv , Vkwvks Izkbzfeax , Dkczu Lhy , Sssurfacer Paint , Izkbzfeax Lhy , Vk;Y Lhy , Putty , Lsavj Csfjax , Jhiri Xqyyk , Gkwq ;Ksd , Qqy ;Ksd , Lsavj Csfjax Jcm+ , Fuse 15Amp , Fuse 20Amp , Head Bulp 90W , Back Light Complete Set , Head Light Complete Set , Indicator Light , Compressor Switch , Fuse 10Amp , Head Bulb 100W , Field , Switch , Armature , Pinion , Clutch Assembly , Solenoid Switch , Bendix , Electrical Plate , Router , Starter , Carbon , Kkw¶V Vksojgkwy , Batu Vksojgkwy ¼Gkwq½ , Batu Vksojgkwy ¼Qqy½ , Czsd Dqiik , Czsd Dqiik Vksojgkwy , Czsd Fmowy Okyko , Czsd Jsfpv Vksojgkwy , Dyp Flaysumj ,Lsecyh , Dyp Flaysumj Fdv , Dyp Iysv , Eklvj Flysumj Vksojgkwy , Fce Ne Dk;Z , Finyk Batu Bhgk , Iaki Uksty , Izskj Vadh Dk;Z , Izslj Ikbzi Tokbav , Izslj Ikbzi Tujy Dk;Z , Jsfm;Svj , Loksz Vksojgkwy , Lsuvj Csfjax Cnyh , Lvsfjax Vksojgkwy , Mhty Ikbzi Ykbzu , Mhty Vadh , Oghy Flysumj Vksojgkwy , Økl Cnyh , Økmu Vksojgkwy , Okvj Ckwmh , Pdk Xzkhflax Aall Tyres , Qzkbohy , Tujy Pdk Vksojgkwy Aall Tyres , Vk;Y Psaut , Vkbz Che Rfkk Lisamy Vksojgkwy , Vsy Lsfvax , Vxyk Batu Bhgk , Xs;J Ckdl Vksojgkwy , Izslj Vadh Dk;Z , Bu Ykbzu Iei , Fmysojh Okyo , ,Ykbzesuv Lizhax , Qhy Iei Fdv , Lfozl Fdv , Yhoj Kk¶V , Gs.M Izkbzej , Qzykbzfcy Kk¶V , Csfjax Lsv , ,Dlhysvj Lk¶V , Iei Uksty Fqfvax , Iei Ckwmh , Dse Iysv , Jksyj Fiu , Liykbz Iei , Pksdmh , Dse Cqk , ,Dlhysvj Cqk , ,Dlhysvj Kk¶V , Jksvj , Fdv Isfdax , Uksty ¼6 Pc½ With Material , Uksty Fmk , Iei Uksty Fqfvax , Mªe Vjfuax , Fdufiu Cqfkax , Gc Csfjax Lhv , Gc Fjax Lhv , Fv;Wc Ne , Kk¶V Fjh Psut , Che Ne , Lisumy Cqfkax Che , Dkmuvj Izsl Pktz , ,Dly Fjh , Lvsfjax Csfjax Lhv , Økmu Csfjax Lvkj Lhv , Økmu Csfjax , Økmu Pqmh , Xs;J Yhoj Fjh , Qzkbzoghy Izslj Iysv , Dyp Csfjax , V~;Wc Csfjax Lhv , V~;Wc Pwmh , Lisumy Csfjax Lhv , Lisumy Pwmh , Lisumy Cqk Lsv , Izkbzej Iei Vksojgkwy Dk;Z , Izkbzej Iei Lfozflax Dk;Z , Ihvhvks Fx;J Vksojgkwy , Brake Drum Turning Lathe Work , Cabin Sealing Labour Work , Crank Grinding Lathe Work , Crank Lathe Work , Crown Housing Bearing Lathe Work , Cut Bearing Lathe Work , Ihvhvks Fx;J Lfozflax , Dsfcu Lhv Uohu@Fjis;J Dk;Z , Qzav Khkk Fqfvax Dk;Z , Radium Work , Paint Writing Work , Side Window , Crane Touchan Per Hour , Material Lifting By Crane Per Hour , Locker Light , Altenator , Show Light , Fce Ne Dk;Z , Finyk Batu Bhgk , Fire Pump Assemble Complete Work , Fire Pump Bushing Lathe Work , Flywheel Facing Lathe Work , Front Kamani Tension Work , Gear Box Assembly Complete Work , Gear Box Repairing Lathe Work , General Wiring Labour/Service , Half Yoke Fitting Lathe Work , Head Assembly Complete Work , Head Face Lathe Work , Head Seat Cutting New Fitting Lathe Work , Kkw¶V Vksojgkwy Dk;Z , Batu Vksojgkwy ¼Gkwq½ Dk;Z , Batu Vksojgkwy ¼Qqy½ Dk;Z , Czsd Dqiik Dk;Z , Czsd Dqiik Vksojgkwy Dk;Z , Epoxy Paint Labour Charge , Laptop Checking Service , Liner Opening Fitting Lathe Work , Dg Set 5 Kva Rent Per Hour , Welding Machine , Lathe Machine , Compressor Machine , Dyp Iysv Dk;Z , Eklvj Flysumj Vksojgkwy Dk;Z , Fce Ne , Finyk Batu Bhgk Dk;Z , Iaki Uksty Dk;Z , Izskj Vadh , Patch Work In Tyre Per Cm Sq , V~;Wc Pwmh Dk;Z , Vkxs Dk Khks Fqfvax Dk;Z , Pump Lathe Job In Main Oil Seal , Pump Nozzle Repair With Material Work , Pump Spray Over Hauling With Material , Puncture Work In Tube Per Cm Sq , Qzkbohy , Rear Kamani Tension , Rear Kamani Welding Work , Rim Fitting Shaft Lathe Work , Spindle Bushing Lathe Work , Spindle Shaft Welding Lathe Work , Lkbzm Ds Khks Dk Fqfvax Dk;Z , Timing Lathe Work , Tube Ne Dk;Z , Tujy Pdk Vksojgkwy , Vk;Y Psaut , Vkbz Che Rfkk Lisamy Vksojgkwy , Vsy Lsfvax , Vxyk Batu Bhgk , Xs;J Ckdl Vksojgkwy , Ih;W Isuv Labour Lfgr Sq.Feet , Oil Paint With Labour Sq.Feet , Biksdlh Isuv Labour Lfgr Sq.Feet , Izkbzej Jsm Vkwdlkbzm Labour Lfgr Sq.Feet , Lsyq Fjisfjax , Fqym Fjisfjax , Csd Ykbzv Dk;Z , Bafmxsvj Ikfzadzzax Ykbzv Dk;Z , Dekuh Ne , Ykwd Yhoj , Kks Ykbzv Cnyh Dk;Z , Gsm Ykbzv Dk;Z , Tujy Okbzfjax Dk;Z , Msk Cksmz Msfuvax Dk;Z Sq.Feet , Kks Msfuvax Dk;Z Sq.Feet , Ckwmh Msfuvax Dk;Z Sq.Feet , Ykwd Yhoj Lq/Kkj@Cnyh Dk;Z , Xsl Csfymax Dk;Z Cm , Bysdvªhd Csfymax Dk;Z Cm , U;K Ckwmh Dk;Z Sq.Feet , Iqjkuk Ckwmh Fjis;J Dk;Z Sq.Feet , Okgu Okvj Vsad U;K Dk;Z Sq.Feet , Dekuh Ne Dk;Z Izfr Dekuh , Psfpl Fjis;J Dk;Z Sq.Feet , Eicher 2095 Pro , Accelerator Paddle , Accelerator Wire , Air Cleaner Rubber , Air Filter Body , Air Pipe , Air Pressure Tank , Altenator , Alternater Bearing , Alternater Cut Out , Alternater Starter , Alternator Assembly , Alternator Body , Back Light Complete Set , Brake Leather Complete Thali , Brake Pad Assembly , Brake Paddle , Brake Pipe , Brake Pipe Big Steel , Brake Pipe Small Steel , Brake Servo Assembly , Brake Shoe Thali , Clutch Bearing Hub , Clutch Fork , Clutch Gear , Clutch Housing , Clutch Housing Bolt , Clutch Paddle , Clutch Plate , Clutch Release Bearing , Clutch Spring , Clutch Washer , Clutch Wire , Diesel Filter , Diesel Filter Body , Diesel Filter Main Pipe , Indicator Light , Kamani Patta New , Kamani Pin , Oil Chamber , Oil Filter , Oil Filter Body
Contract Date: Jun 19, 2026 Contract Value : 82.21 Lakh
Local Bodies No of Bidders 2
Madhya Pradesh View Result →
24.
Chemicals and Fertilizers #11000276 AOC
Bids Are Invited For Custom Bid For Services - Annual Rate Contract For Instrument Maintenance Jobs For Year 2026.; Removal of Control Valves from pipelines at all elevations in plant, Pr. Rating up to and including 600 LBS & Valve Body size as under : 10.1 i)  up to and including 2” 10.2 ii) above 2”, up to & including 4” Transportation of Control Valves to & from Workshop. Pr. Rating up to and including 600 LBS & Valve body size as under: 10.3 i)   up to and including 2” 10.4 ii)  above 2”, up to & including 4” Fixing of Control Valves at all elevations in Plant after bringing from Workshop after repairs, End connections to be cleaned and new Gaskets to be provided, Pr. Rating up to and including 600 LBS & Valve Body size as under 10.5 i)   up to and including 2” 10.6 ii)  above 2”, up to & including 4” Removal of Control Valves from pipelines at all elevations in plant, Pr. Rating > 600 LBS & Valve Body size as under : 10.7 i)     up to and including 2” 10.8 ii)    above 2”, up to & including 4” Transportation of Control Valves to & from Workshop Pr. Rating >600 LBS & Valve Body size as under : 10.9 i)    up to and including 2” 10.10 ii)   above 2”, up to & including 4” Fixing of Control Valves at all elevations in Plant after bringing from Workshop after repairs, End connections to be cleaned and new gaskets to be provided, Pr. Rating > 600 LBS & Valve Body size as under : 10.11 i)    up to and including 2” 10.12 ii)   above 2”, up to & including 4” 10.13 Removal of Control Valve from Bonnet & Re-fixing, old Gasket to be removed & new Gasket to be provided. Valve Body size up to & including 6 10.14 Removal of Control Valve from Bonnet & Re-fixing, old gasket to be removed & new gasket to be provided. Valve Body size above 6, up to & including 18. 10.15 Removal & Fixing of Actuator of control valve. Valve Body size up to & including 8 10.16 Removal & Fixing of Actuator of control valve. Valve Body size above 8”, up to & including 18 10.17 Removal of Different Type Flow Meters(Oval gear meter/Magnetic/ Mass) size up to & including 4 Irrespective of Pr. Rating 10.19 Transportation to & from W/shop of Different Type Flow Meters (Oval gear meter/Magnetic/Mass) Irrespective of Pr. Rating & Size. 10.20 Fixing of Different Type Flow Meters (Oval gear meter /Magnetic/Mass) size up to & including 4 Irrespective of Pr. Rating. 10.18 Removal of Ultra Filter size up to & including 4 10.21 Fixing of Ultra Filter size up to & including 4 10.22 Removal & refixing of orifice plates at all elevations in the plant and provision of new gaskets for following Line size, all pressure ratings :- Up to & including 4” Fabrication, clamping, supporting, painting of inclined sheds on junction boxes and instruments etc. made of MS angle & aluminum sheet 10.23 i)   Size 3 feet x 2 feet 10.24 ii)  Size 4 feet x 2 feet 10.25 Complete removal and refixing of displacer type/ capacitance type/ magnetic type / Capillary type /level transmitters, level gauges, level switches (all sizes and pressure ratings) from various vessels at all elevations in the plant, and to provide new gaskets. 10.26 Transportation to & from Workshop of displacer type/ capacitance type/ magnetic type / level transmitters, level gauges, level switches (all sizes and pressure ratings) from various plants. Removal and refixing of power cylinders of dampers etc. 10.27 I) up to and including 3 dia. 10.28 ii) above 3 up to and including 6 dia. Transportation to & from Workshop of Power Cylinder : 10.29 I) up to and including 3 dia. 10.30 ii) above 3 up to and including 6 dia. Laying of cable trays with proper angle iron supports(welding & grouting included), also proper grouting of old structures for following sizes of trays :- 10.31 i)   50 mm wide cable tray 10.32 ii)  100 mm wide cable tray 10.33 iii) 150 mm wide cable tray 10.34 iv)  300 mm Wide cable tray Removal of old corroded cable trays from plant of following sizes : 10.35 i)  50 mm wide tray 10.36 ii) 100 mm wide tray 10.37 iii) 150 mm wide tray 10.38 iv) 300 mm wide tray Laying and clamping of armored signal, power, conduit pipes or thermocouple extension cables (armored) with conductor size up to 2.5 mm² on cable trays with proper glanding at both ends. Angles/ducts, of following sizes :- 10.39 i)  2/3/4 core x 0.5/1.5 mm² 10.40 ii) 12/19/24 core x 0.5/1.5 mm² Clamping & fixing of already layed cable in various plants of following sizes having bunch up to 10-15 cables : 10.41 i)  2/3/4 Core x 0.5/1.5 mm² 10.42 ii) 12/19/24 Core x 0.5 /1.5 mm² 10.43 Removal of signal, power, corroded cables with conduit pipes or thermocouple extension cables (armored) with conductor size up to 2.5 mm2.. The job includes opening of terminals, unclamping from trays or angle irons etc., opening of glands at both ends, Transportation of cables to storage place from site, winding of removed cable on empty cable drums if required.( Irrespective of no. of cores) Laying and clamping of SS tubes in trays/ducts/angles, making connections at both ends using compression fittings, leakage checking, installation of associated air filter regulators and solenoid valves etc.Tubes in following sizes :- 10.44 i)  6 mm OD SS tube 10.45 ii) 10 mm OD SS tube 10.46 iii) 12 mm OD SS tube 10.47 Removal of SS tubes up to 10 mm OD size from trays/ducts/angles at any elevation after disconnecting from instruments & Transport to store/Inst. Workshop( if required). 10.48 Removal of 2/3 way Ex. Proof electrical junction boxes. The job includes removal of cables from old junction boxes. All cables & JBs to be sent to Store/ Inst. workshop. 10.49 Fixing of 2/3 way Ex. Proof electrical junction boxes. The job includes Mounting of new junction box after fabrication and painting of new mounting bracket and cable glanding. 10.50 Removal 6/8/12 way Ex. Proof electrical junction boxes. The job includes removal of cables from old junction boxes. All cables & JBs sent to store/Inst. Workshop. 10.51 Fixing of 6/8/12 way Ex. Proof electrical junction boxes. The job includes mounting of new junction box after fabrication and painting of new mounting bracket and cable glanding. 10.52 Replacement of head bolts of Level Trolls at all elevations in the plant.(Sixteen Bolts per LT) 10.53 Removal and refixing of Flange type isolation valves of level trolls, level gauges, level switches at all elevations in the plant, cleaning of end connections and providing new gaskets.Size up to and including : 50 NB, PN 250. 10.54 Removal of Flange type isolation valves of Level Trolls, Level Gauges and Level Switches at all elevations in the plant and providing blind flanges. Cleaning of end connections and new gaskets to be provided.Size up to & including : 50 NB, PN250. Removal of Differential Pressure / Pressure transmitters /Diaphragms Seal Type Pressure gauges/Thermowells. 10.55 (i)Diaphragm Seal Type transmitters/gauge with or without capillary with flange size up to & including 80mm. 10.56 (ii) Ordinary Transmitter/Gauge/Thermowells Fixing of Diaphragm Seal Type Differential Pressure/Pressure transmitters/Pressure gauges. 10.57 (i)Diaphragm Seal Type transmitters/gauge with or without capillary with flange size up to & including 80mm. 10.58 (ii) Ordinary Transmitter/Gauge//Thermowells Transportation of differential pressure / pressure transmitter/Pr. gauge to & from Workshop 10.60 (i)Diaphragm Seal Type transmitters/gauge with or without capillary with flange size up to & including 80mm. 10.61 (ii)Ordinary Transmitter/Gauge 10.62 Panel cutting, Job includes hacksaw cutting, edge preparation to make the cutout suitable for instrument mounting. 10.63 Fabrication of mounting frames and supports for instruments from angle irons/flats/channels or pipes, applying primer & painting the fabricated frames/supports. 10.64 Tightening of flange of control valve, valve body size up to and including 4 10.65 Replacement of flange gaskets on both sides of control valve , valve body size up to and including 4 Removal / fixing of any flange at all elevations in plant, pr. rating up to and including 600 LBS & size as under 10.66 Up to and including 2” 10.67 above 2”, up to & including 4” Removal / fixing of any flange at all elevations in plant, pr. rating >600 LBS & size as under : 10.68 Up to and including 2” 10.69 above 2”, up to & including 4”
Contract Date: Ref. Documents Contract Value : 67.89 Lakh
Boards / Undertakings / PSU No of Bidders 4
34.
Power #10912822 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer-Handling and dragging of transformer from stacking yard to repairing hall.10KVA25KVA63KVA100KVACutting of Sealed transformers top cover plate smoothly and uniformally by gas/chisel cutter or opening of top cover plat and detanking of core and coil assembly.10KVA25KVA63KVA100KVADragging of the tank from the repaired hall to yard. & cleaning oil and dust etc. and scraping the rust etc and Washing of Transformer tank with Caustic Soda & water, Caustic soda shall be provided by contractor10KVA25KVA63KVA100KVAPainting of inner side of transformer tank and channels with heat proof zinc chromate paint of good quality (Berger, Nerolac, Jenson & Nicholson etc) shall be 10KVA25KVA63KVA100KVADragging out empty tank from yard to repairing hall.10KVA25KVA63KVA100KVADismantling core and coil assembly and cleaning of dust and dirt from the core assembly and checking of LV and HV leg coils for assessing its reuse, rechecking and recording of physical dimensions of coil and cleaning of core and their components etc.10KVA25KVA63KVA100KVAReconditioning of minor damaged in HV/LV leg coil/ Strip of transformer. work includes removing of damage part DPC insulation and providing new DPC on same HV coil/LV Strip should be properly cleaned and should be made of same size as of original .25KVA63KVA100KVA‘‘Making of complete LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.10KVA25KVA63KVA100KVA‘‘Making of complete HV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.10KVA25KVA63KVA100KVAAssembly of core and coils and fitting of other parts requiring replacement such as press board, making supports between adjacent sections by insulating spares and rapping etc & tapping etc. (Breezing/soldering) required, shall be arrange by the contractor.10KVA25KVA63KVA100KVAShifting and keeping the assembled core coil etc. in Oven from the repairing and assembly place.10KVA25KVA63KVA100KVATaking out assembled core and coils assembly from the OVEN and shifting to repairing hall.10KVA25KVA63KVA100KVARetanking of complete assembly into painted tank and lightening of the assembly in the tank safely. Fitting of all accessories of the transformer.10KVA25KVA63KVA100KVAWelding of repaired transformers including of top cover plate by electric core welding filling of gaps or fixing of top cover plate by properly nuts & bolts to prevent seepage of water..10KVA25KVA63KVA100KVAPainting of t/f outside with super enamel synethics paint of yellow color in two coats after providing primer of red oxide paint etc. paint & painting materials shall be provided by contractor.10KVA25KVA63KVA100KVADragging of repaired T/f upto the test cabin/testing place for testing and their re-dragging to yard and its stacking at indentified place after testing10KVA25KVA63KVA100KVATesting the correctness of connection, DVDF, No load, load loss test (where available), High Voltage, impedance voltage, Short Circuit and open circuit test, Voltage ratio on various tap position.10KVA25KVA63KVA100KVAPunching and welding of M.S. Plate on outside of transformer of size 100 mm x 50mm x 3 mm containing/ punching. (a) of unique number as decided by the department with a punch head. (b) Date of repair. 10KVA25KVA63KVA100KVA
Contract Date: Ref. Documents Contract Value : 87.25 Lakh
Government Departments No of Bidders 4
Uttar Pradesh View Result →
35.
Power #10912820 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer-Handling And Dragging Of Transformer From Stacking Yard To Repairing Hall. 10Kva 25Kva 63Kva 100Kva Cutting Of Sealed Transformers Top Cover Plate Smoothly And Uniformally By Gas/Chisel Cutter Or Opening Of Top Cover Plat And Detanking Of Core And Coil Assembly. 10Kva 25Kva 63Kva 100Kva Dragging Of The Tank From The Repaired Hall To Yard. & Cleaning Oil And Dust Etc. And Scraping The Rust Etc And Washing Of Transformer Tank With Caustic Soda & Water, Caustic Soda Shall Be Provided By Contractor 10Kva 25Kva 63Kva 100Kva Painting Of Inner Side Of Transformer Tank And Channels With Heat Proof Zinc Chromate Paint Of Good Quality (Berger, Nerolac, Jenson & Nicholson Etc) Shall Be 10Kva 25Kva 63Kva 100Kva Dragging Out Empty Tank From Yard To Repairing Hall. 10Kva 25Kva 63Kva 100Kva Dismantling Core And Coil Assembly And Cleaning Of Dust And Dirt From The Core Assembly And Checking Of Lv And Hv Leg Coils For Assessing Its Reuse, Rechecking And Recording Of Physical Dimensions Of Coil And Cleaning Of Core And Their Components Etc. 10Kva 25Kva 63Kva 100Kva Reconditioning Of Minor Damaged In Hv/Lv Leg Coil/ Strip Of Transformer. Work Includes Removing Of Damage Part Dpc Insulation And Providing New Dpc On Same Hv Coil/Lv Strip Should Be Properly Cleaned And Should Be Made Of Same Size As Of Original . 25Kva 63Kva 100Kva ‘‘Making Of Complete Lv Leg Alu. Leg Coils Identical To Original One With Same Number Of Turns, Weight Etc Providing Super Enameled / Dpc Conductor/ Strip Confirming To Is 1971 /53 In Place Of Old And Damage Coil. Alu. Coil, Wire Strip Will Be Provided By The Department. All Coil Assembly Of Identical Voltage Shall Be Interchangeable Without Requiring Any Special Equipment. Coil Shall Be Supported Between Adjacent Sections By Insulations, Spacers, Beamers And Other Insulations.Rewinding Shall Be Arranged To Ensure Free Circulation Of Oil To Reduced Hot Spots In Winding. The Insulation Of Coil Shall Be Treated With Suitable Insulating, Varnish Or Equivalent Compound To Develop The Full Electrical Strength Of Winding As Per Original Design. 10Kva 25Kva 63Kva 100Kva ‘‘Making Of Complete Hv Leg Alu. Leg Coils Identical To Original One With Same Number Of Turns, Weight Etc Providing Super Enameled / Dpc Conductor/ Strip Confirming To Is 1971 /53 In Place Of Old And Damage Coil. Alu. Coil, Wire Strip Will Be Provided By The Department. All Coil Assembly Of Identical Voltage Shall Be Interchangeable Without Requiring Any Special Equipment. Coil Shall Be Supported Between Adjacent Sections By Insulations, Spacers, Beamers And Other Insulations.Rewinding Shall Be Arranged To Ensure Free Circulation Of Oil To Reduced Hot Spots In Winding. The Insulation Of Coil Shall Be Treated With Suitable Insulating, Varnish Or Equivalent Compound To Develop The Full Electrical Strength Of Winding As Per Original Design. 10Kva 25Kva 63Kva 100Kva Assembly Of Core And Coils And Fitting Of Other Parts Requiring Replacement Such As Press Board, Making Supports Between Adjacent Sections By Insulating Spares And Rapping Etc & Tapping Etc. (Breezing/Soldering) Required, Shall Be Arrange By The Contractor. 10Kva 25Kva 63Kva 100Kva Shifting And Keeping The Assembled Core Coil Etc. In Oven From The Repairing And Assembly Place. 10Kva 25Kva 63Kva 100Kva Taking Out Assembled Core And Coils Assembly From The Oven And Shifting To Repairing Hall. 10Kva 25Kva 63Kva 100Kva Retanking Of Complete Assembly Into Painted Tank And Lightening Of The Assembly In The Tank Safely. Fitting Of All Accessories Of The Transformer. 10Kva 25Kva 63Kva 100Kva Welding Of Repaired Transformers Including Of Top Cover Plate By Electric Core Welding Filling Of Gaps Or Fixing Of Top Cover Plate By Properly Nuts & Bolts To Prevent Seepage Of Water.. 10Kva 25Kva 63Kva 100Kva Painting Of T/F Outside With Super Enamel Synethics Paint Of Yellow Color In Two Coats After Providing Primer Of Red Oxide Paint Etc. Paint & Painting Materials Shall Be Provided By Contractor. 10Kva 25Kva 63Kva 100Kva Dragging Of Repaired T/F Upto The Test Cabin/Testing Place For Testing And Their Re-Dragging To Yard And Its Stacking At Indentified Place After Testing 10Kva 25Kva 63Kva 100Kva Testing The Correctness Of Connection, Dvdf, No Load, Load Loss Test (Where Available), High Voltage, Impedance Voltage, Short Circuit And Open Circuit Test, Voltage Ratio On Various Tap Position. 10Kva 25Kva 63Kva 100Kva Punching And Welding Of M.S. Plate On Outside Of Transformer Of Size 100 Mm X 50Mm X 3 Mm Containing/ Punching. (A) Of Unique Number As Decided By The Department With A Punch Head. (B) Date Of Repair. 10Kva 25Kva 63Kva 100Kva
Contract Date: Ref. Documents Contract Value : 39.90 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
36.
Defence #10898109 AOC
Tender For Repair Replacement And Servicing Ht Equipments Including Replacement Of Old Ht Cables And Its Connected Works At Aundh Military Station Under Ge Mh And Rh Khadki; 1 Disconnecting the HV(22KV) & LV(0.415kV) side electrical connections including neutral earth strip of existing step down transformer, drain out the complete oil of transformer and store carefully in clean container. Cleaning of all HV/LV windings terminals, cleaning of conservator tank, cooling fins/tubes, tank, etc. Thuroughly inspecting of core and winding complete, reinsert the core coil assembly into the transformer tank, replacing 5/3 mm thick rubberised corksheet gasket of top cover complete and refilled with filtered transformer oil upto the desired level marked in conservator tank and record the insulation resistance of the winding both HV/LV side between earth and HV/LV winding, reconnecting the HV/LV side electric cables complete of following capacity of stepdown transformer all as specified and directed.Note - Transformer oil filtration and top up shall be measured and paid seperately under the relevant item of schedule 2 Transformer capacity 100KVA to 250 KVA 3 Transformer capacity 300KVA to 500 KVA 4 M&L for dehydration of transformer oil with mobile stream line transformer oil filteration plant at site with all accessories connected to transformer and carrying out filterartion of oil to desired dielectric strenghtto achieve electric strength of 60 KV for 1 minute at 2.5 mm gap as per relevant IS fortransformer installed at various locations out door/in door type all as specified and directed by the Engineer in Charge Note : Test certificate shall be submitted for before and after filteration for dielectric strenght on the proper format. (ii) Transformer oil used for top up will be measured and paid seprately under relevant item. 5 Supply and topping up new transformer oil confirming to IS -335 of 1993 into the conservator tank/body tank of the transformer at various location all as specified and directed. Make : Power Oil or its equivalent. Note : The transformer oil for topping up shall be with di-electric strength of 40KV 6 Disconnecting all in coming and outdoor cables removing the transformer from the platform/two pole structure and floor and loading it in the vechicle carefully using the crane and transporting it to the workshop for repairs and transformer transport back to site, reinstall it, reconnecting all incoming and outgoing cable by properly crimping using lugs of suitable size taping the bushes/busbar, using insulation tape and testing of capacity 200 KVA to 500 KVA all as specified and directedNote :LT/HT side ceramic busing, brass spindle for HT/LT side, Rewinding, Dehydration of oil shall be measured and paid seprately in respective Items 7 M&L for rewinding of HT /LT windings oftransformer, winding the defective coils with approved quality copper wire as per IS of same gauge and existing size together with new insulation materials, bracings the terminals before placing into the tranformer and assembling the HT / LT coil with new insulation between core and LT coil all as required and fitting the coils in the chamber, testing and commisioning the transformer after providing necessary connections all as specified and directed 8 M&L for arrest the leakage of transformer oil from the LT/HT side bushings by replacing oil seals, Gaskets of, top cover, conservator tank and other parts of transformer afterdrain out the transformer at required level, tigtning the transformer nut bolts, replacing the gasket nuts, bolts, washer and refilling thestrored Transformer oilafter completion of oil arrest all as specifeid and directed.Note : (i) Spares requiredsuch as nut, bolts, washer, Gasket etc required to oil arrest shallbe deemed in quoted rate.(ii) Topping up of extra transforemer oil required to achieve desired level measured and paid seprately. (iii) HT/LT side complete bushing assemble with brass stud & oil seal shall be measured & paid under relevent items of schedule. 9 Supply only HT side bushing 22KV with oil sealfor 100 to 250 KVA 10 Supply only HT side bushing 22KV with oil seal for 300 to 500 KVA 11 Supply only LT side bushing 415Vwith oil sealfor 100 to 250KVA 12 Supply only LT side bushing 415V with oil sealfor 300 to 500 KVA 13 Replacement of breather assembly complete with silica jel in transparent container with metallic top and bottom cup with pipe entry of 15/20 mm dia, including oil bath tub all as specified and directed 14 Replacement of existing unserviceable silica gel with new crystal clear silica jel for breather of transformer all as specified and directed 15 Supply only brass spindle on LT side as per existing size, shape and specification for capacity range 100 KVA to 500 KVA all as specified and directed 16 Supply only brass spindle on HTside 22 KVas per existing size, shape and specification for capacity range 100 KVA to 500 KVA all as specified and directed 17 M&L for overhauling servicing of Tap changer and replacement of unserviceable parts as ordered with new and assembling with old serviceable parts for smooth functioning and operation all specified and directed. 18 M&L for transformerpainting with twocoat of synthetic enamel paint heat proof of same colour including preparation of old surfaces complete includuing writing the MES no in bold letter all as specified and directed. 19 M&L for painting to two pole structure with twocoats of aluminumpaintoverred oxide paint after preparation of old surfaces as per existing all as specified and directed. 20 M&L for painting to four pole structure with two coats of aluminum paint over red oxide paint after preparation of old surfaces as per existing all as specified and directed. 21 M&L for spray painting to exposed surface of steel tubular pole HT pole 11 metre long with two coats of synthetic enamel aluminium paint (as per existing colour) over a coat of red oxide primer including preparation of old painted surface by scrapping or complete removal of old paint, filling cavities with filler all as specified and directed 22 S&F in replacement of tubular aluminium alloy bus bar 12 mm thichness of 32 mm outer dia and 20 mm inner dia with colour code of Red, yellow & blue coupled with Al Clamps 120 mm Length 6 mm thickness mounted on polymer based 22 KV type insulators suitable for HT 22 KV two/four pole structures in horizontal layers duly coupled with strip jumbers, Lightning arrestors all as specified and directed 23 S&F in replacement of solid aluminium strip of 30 mm x 10 mm with colour code suitable for HT 22 KV two/four pole structures in verticle layers fixed in polyglass/epoxy & cycloaliphatic insulators duly coupled with horizantal bus bars, Lightning arrestors, drop out fuse assembly, Gang operated device all as specified and directed 24 S&F for Insulator Pin/ post type polymer based including one galvanishing MS spindle, nuts & washers for 22 KV grade and fixing to the structure all as specified and directed 25 S&F in repairs switch air break gang operated HT 22 KV Volt grade out door type, triple pole of capacity 200 amps rating mounted on Polymer based 9 insulator and fitted on steel frame horizontally mechanically operated mechanism from ground level consisting of operating rod of 25 mm bore Heavy grade GI pipe of suitable length worked from ground level and with locking arrangements including pad locks with key flat iron clamp 50 mm x 6 mm including taking down old unseviceable one all as specified and directed. Make: Pactil /Jaipuria Brothers / MEC Trivandrum 26 Supplying, installing, fixing, connecting and testing of polymer based Drop-out fuse set (set of 3 nos), mounted on insulators with steel frame 200 Amps capacity, siutable for 22KV, HT system, out door type, including Expulsion fuse carriers and fuse element Upto 25 Amp, including taking down old unserviceable one all as specified and directed 27 M&L in repais Lightning arrester high tension expulsion type complete with all fittings transmission class, discharge capacity 30 Kilo amps suitable for 22000 Volts supply including taking down old lightning arresters all as specified and directed 28 M&L for detect HT 22 KV cable faultfor various size of cable ofwith technician round the clock on Md Accn and OTM accn at Aundh Mil Stn areas detect the cable fault and necessary excavation of soil and refilling the soil, joint the faulty cable with new straight through joint kit, after jointing, testing, and charging of HT / LT cable all as specified and directed by Engr-in-Charge. Note: (i) Cable joint required size measured and paid separately (ii) Each job considered cable fault locator use in one day 29 M&L in repairs for errecting steel tubular swaged poles in true vertical position ( or to be fixed in an inclined positon as strut pole) steel tubular swaged poles complete with MS base plate of 6 mm thick of size 450x450 mm finial taper plug, pole cap, bolts, nuts and washer and screwd pole madeout of ERW MS tubing confirming to IS -2713 (part-II) 1980 type 410 SP-55 (11 meters long) pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete.(For 2 pole Structure) all as specified and directed 30 Disconnecting ACSR conductor any type and supply and fixing ACSR conductor of any size/ type for OH line on poles insulator for jumpering connection including binding insulators with alluminium wire all as specified and directed 31 M&L for Cradles, hexagonal/rectangular, fabricated with galvanised steel wire 4 mm dia all as specified and directed. 32 M&L in repairs for cross arms, bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washer, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat and one finishing coat of coat of paint all as specified and directed by Engr in charge 33 S&F in repairs Danger notice platefor HTof size 25 cm x 20 cm of 1.6mm thick mild steel sheet, veterious enamelled white with letter, fighers and conventional skull and bones with signal red colour and fixed with MS clamps, bolts and nuts all as specified and directed. 34 M&L PCC 1:4:8type D2 (using 40 mm graded crushed stone aggregate) for PCC pole/struts, stay assembly,foundation filling and mass concrete all as specified and directed. 35 M&L PCC 1:3:6type C1, (using 20 mm graded crushed stone aggregate) as in coping of pole all as specified and directed. 36 Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in soft / loose soil all as specified and directed. 37 Excavation in trenches n.exc 1.50 m wide and not exc 1.5 m depth and getting out in hard / dense soil all as specified and directed. 38 Excavation in trenches n.exc 1.50 m wide andexc 1.5 m depth and getting out in soft disintegratedsoil all as specified and directed. 39 Returing, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm in soil all as specified and directed. 40 Removing excavated materials not exc 50m and depositing where directed at a level not exc 1.5m above the starting point all as specified and directed. 41 M&L for riddled earth for cushioning to under ground cable in trenchesincluding spreading, levelling handpunning and consolidateall as specified and directed. Note : For the purpose of payment only punned thickness will be measured. 42 Supplying and laying reinforcedpre cast concrete cable cover, class EHV, type-1, with peak size450mmx230mmx50mm laid in trench as protection to cable all as specified and directed 43 Taking down burnt bricks / PCC covers of any size and relaying the same after laying of cable all as directed and specified. 44 M&L for road cutting for laying GI pipe for protection of cable upto depth 90 cm including making goodthe disturbedroad and redressing the disturbed surfaces of road with filling concrete type D-2 PCC 1:4:8 (using 40 mm graded crushed stone aggregate) all as specified and directed. (For HT/LT cable) 45 S&F in repairs GI pipe size 100 mm bore, Light grade(ISI marked) laid in trenches/ path /road crossings/ fixed to poles/ceiling/ along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required all as specified and directed. 46 Supply and laying HT underground cable 95 sqmm x 3 core XLPE insulated, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with sranded aluminium conductor 22000 volts grade including dismantling of old HT cables laid in trenches/passing through pipes or fixed on poles/wall/floor all as specified and directed. 47 All as per item No 40above but of Size 120 sqmm x 3 core 48 All as per item No 40above but of Size 185 sqmm x 3 core 49 All as per item No 40above but of Size 300 sqmm x 3 core 50 M&Lin repairs cable jointing kit of Size 95 sqmm x 3 core, 22 KV (Earthed) grade of cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable all as specified and directed by Engr-in-charge. 51 All as per item No 44above but ofSize 120 sqmm x 3 core to 185 Sqmm x 3 Core 52 All as per item No 44above but ofSize 240 Sqmm 3 Core to 300 sqmm x 3 core 53 M&L in repairs cable jointing kit Size 95 sqmm x 3 core for 22 KV(Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable all as specified and directed. 54 All as per item No 47above but of Size 120 sqmm x 3 core to 185 Sqmm x 3 Core 55 All as per item No 47above but ofSize 240 Sqmm 3 Core to 300 sqmm x 3 core 56 M&L forheat shrinkable HT 22 KV (earthed) straight through joint Size 95 sqmm x 3 core cable kit suitable for aluminium conductor cable all as specified and directed 57 All as per item No 50above but ofSize 120 sqmm x 3 core to 185 Sqmm x 3 Core 58 All as per item No 50above but ofSize 240 Sqmm 3 Core to 300 sqmm x 3 core 59 M&L for triming of tree branches with in 2.0 mtr on either side of the electric line/ poles with suitable T & P and depositing the waste all as specified and directed. 60 M&L for cable route indicator made out of Cast ironof dia 100 mm embrosed with HT cablewith 25mm x 5 mm GI flat of lenth 1 metreincluding painting with two coats of synthetic enamel red colour paint over a coat of primer to exposed surfaces all as specified and directed by the Engineer-in-charge. 61 Maintenance, Serviceing and calibration of 22 KV HT POVCBcomprises of the following:-(a) Checking the 22 KV HT POVCB/(SF 6 type) of 1600 Amps ratingHT panel after switching off electric supply checking of mechanical system for proper functioning of upward/downward movement of HT POVCB including servicing the CR Panel& checking the mechanical system. Cleaning & servicing the fixed/moving contact & blowing out dust and applying the proper lubrication/greasing theincluding replacing the control cables as required for connection to CR panel (b) Taking out relay set ( 2 Nos over current & 01 No earth fault relay) of any make from HT 22 KV CR panel and cleaning the contact(NO+NC) by CTC solution and adjust the contact and calibrate the relay by relay testing kit & proper plug setting as per reqd load & time delay and fixing the relay set in HT panels complete all as specified and directed. Note for (a) & (b):- (i) Testing of above job to be carried out by engineers of authorised dealer/service centre of concerned OBC. (ii) Replacing new items shall be measured and paid separately as supply only. (iii) Contractor shall submit the connected document/graph for relay calibration duly authenticated by authorised dealer/service center. 62 S&F Over current /earth fault protection Relay suitable for HT CR Panel ofcapacity24 V to 240 V AC/DC, 22KV, 3 ph, 50 Hz all as specified and directed by Engineer in Charge. Make- ASHIDA/CROMPTON / L & T/ SPHNEIDER 63 S&FVacuum interrupter bottle suitable for HT POVCB ofCapacity 1250 AMP, 22KV, 3 ph, 50 Hz Panel, all as specified and directed.Make- CROMPTON /ABB and equivallent 64 S&F Spring ChargeMotor suitable for HT POVCB of240V AC, 22KV, 3 ph,50 Hzall as specified and directed Make- CROMPTON/ ABB and Equilent 65 S&F Triping /Closing coilfor POVCB of 24V DC, 22KV, 3PH, 50Hz all as specified and directed.Make- CROMPTON 66 S&F TNC Switch ON/OFF suitable for 22 KV CR panel suitable for HT POVCB ofcapacity 16AMP 4P, 22KV, 3 ph,50 Hz Panel all as specified and directed.Make- CROMPTON/ AREVA 67 M&L for Servicing 22 KV HT RMU (Ring Main Unit), type - RM6, of capacity 630A/800A, 22KV, 3 ph, 50 Hz Panel, comprising the following works. Make-C&S (a) check the auxilliry switch, shunt trip assembly, closing/Trip solenoid, limit switch and complete control wiring all as specified and directed 68 Over hauling and testing of secondary injection of over current and earth fault relay of HT RMU 22 KV panel on each multiple setting, readjustment and calibration the same complete, checking of control wiring including testing on completion all as specified and directed. 69 Supplyonly of the following material for VCBs/RMU all as specified and as directed. 70 Charging motor, single phase working on 240 volts Ac 71 Closing/tripping coil operated on 110 /30 volt system 72 Tripping coil operated on 110 /30 volt system 73 loading Spring 74 latch switch assly 75 Space heater 76 Thermostat for Space heater 77 Refilling onsite SF6 Gas, required for 22 KV VCBs/RMUs 78 M&L for cleaning of MES electric supply installations/campus by surface dressing or trimming of natural ground to remove small unequalities (including removing vegetation/ shrubs/brush wood/under growth) and carrying away the rubbish to a distance of not exc 50 mtr away for the various sub stations including spray of herbsite all as specified and directed. 79 M&L forhardcore of gauge n.exc 63mm, deposited, spread, and levelled in layers n.exc15 cm thickness (below or above ground level), water and rammed to a true shape with broken stone or boulders existing available on site and making good all as specified and directed.( Sub Station Yard) 80 M&L of Synthetic insulating mat confirming to IS 15652:2006 of size 2mx1m x3mm thick for voltage up to 22/33 kv all as specified and directed by Engr in charge.
Contract Date: Apr 28, 2026 Contract Value : 19.12 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 8
Maharashtra View Result →
37.
Power #10842228 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer- 1 Handling And Dragging Of Transformer From Stacking Yard To Repairing Hall. 1.01 10Kva 1.02 25Kva 1.03 63Kva 1.04 100Kva 2 Cutting Of Sealed Transformers Top Cover Plate Smoothly And Uniformally By Gas/Chisel Cutter Or Opening Of Top Cover Plat And Detanking Of Core And Coil Assembly. 2.01 10Kva 2.02 25Kva 2.03 63Kva 2.04 100Kva 3 Dragging Of The Tank From The Repaired Hall To Yard. & Cleaning Oil And Dust Etc. And Scraping The Rust Etc And Washing Of Transformer Tank With Caustic Soda & Water, Caustic Soda Shall Be Provided By Contractor 3.01 10Kva 3.02 25Kva 3.03 63Kva 3.04 100Kva 4 Painting Of Inner Side Of Transformer Tank And Channels With Heat Proof Zinc Chromate Paint Of Good Quality (Berger, Nerolac, Jenson & Nicholson Etc) Shall Be 4.01 10Kva 4.02 25Kva 4.03 63Kva 4.04 100Kva 5 Dragging Out Empty Tank From Yard To Repairing Hall. 5.01 10Kva 5.02 25Kva 5.03 63Kva 5.04 100Kva 6 Dismantling Core And Coil Assembly And Cleaning Of Dust And Dirt From The Core Assembly And Checking Of Lv And Hv Leg Coils For Assessing Its Reuse, Rechecking And Recording Of Physical Dimensions Of Coil And Cleaning Of Core And Their Components Etc. 6.01 10Kva 6.02 25Kva 6.03 63Kva 6.04 100Kva 7 Reconditioning Of Minor Damaged In Hv/Lv Leg Coil/ Strip Of Transformer. Work Includes Removing Of Damage Part Dpc Insulation And Providing New Dpc On Same Hv Coil/Lv Strip Should Be Properly Cleaned And Should Be Made Of Same Size As Of Original . 7.01 25Kva 7.02 63Kva 7.03 100Kva 8 ‘‘Making Of Complete Lv Leg Alu. Leg Coils Identical To Original One With Same Number Of Turns, Weight Etc Providing Super Enameled / Dpc Conductor/ Strip Confirming To Is 1971 /53 In Place Of Old And Damage Coil. Alu. Coil, Wire Strip Will Be Provided By The Department. All Coil Assembly Of Identical Voltage Shall Be Interchangeable Without Requiring Any Special Equipment. Coil Shall Be Supported Between Adjacent Sections By Insulations, Spacers, Beamers And Other Insulations.Rewinding Shall Be Arranged To Ensure Free Circulation Of Oil To Reduced Hot Spots In Winding. The Insulation Of Coil Shall Be Treated With Suitable Insulating, Varnish Or Equivalent Compound To Develop The Full Electrical Strength Of Winding As Per Original Design. 8.01 10Kva 8.02 25Kva 8.03 63Kva 8.04 100Kva 9 ‘‘Making Of Complete Hv Leg Alu. Leg Coils Identical To Original One With Same Number Of Turns, Weight Etc Providing Super Enameled / Dpc Conductor/ Strip Confirming To Is 1971 /53 In Place Of Old And Damage Coil. Alu. Coil, Wire Strip Will Be Provided By The Department. All Coil Assembly Of Identical Voltage Shall Be Interchangeable Without Requiring Any Special Equipment. Coil Shall Be Supported Between Adjacent Sections By Insulations, Spacers, Beamers And Other Insulations.Rewinding Shall Be Arranged To Ensure Free Circulation Of Oil To Reduced Hot Spots In Winding. The Insulation Of Coil Shall Be Treated With Suitable Insulating, Varnish Or Equivalent Compound To Develop The Full Electrical Strength Of Winding As Per Original Design. 9.01 10Kva 9.02 25Kva 9.03 63Kva 9.04 100Kva 10 Assembly Of Core And Coils And Fitting Of Other Parts Requiring Replacement Such As Press Board, Making Supports Between Adjacent Sections By Insulating Spares And Rapping Etc & Tapping Etc. (Breezing/Soldering) Required, Shall Be Arrange By The Contractor. 10.01 10Kva 10.02 25Kva 10.03 63Kva 10.04 100Kva 11 Shifting And Keeping The Assembled Core Coil Etc. In Oven From The Repairing And Assembly Place.
Contract Date: Ref. Documents Contract Value : 46.85 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
39.
Power #10842174 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer-Handling and dragging of transformer from stacking yard to repairing hall.10KVA25KVA63KVA100KVACutting of Sealed transformers top cover plate smoothly and uniformally by gas/chisel cutter or opening of top cover plat and detanking of core and coil assembly.10KVA25KVA63KVA100KVADragging of the tank from the repaired hall to yard. & cleaning oil and dust etc. and scraping the rust etc and Washing of Transformer tank with Caustic Soda & water, Caustic soda shall be provided by contractor10KVA25KVA63KVA100KVAPainting of inner side of transformer tank and channels with heat proof zinc chromate paint of good quality (Berger, Nerolac, Jenson & Nicholson etc) shall be 10KVA25KVA63KVA100KVADragging out empty tank from yard to repairing hall.10KVA25KVA63KVA100KVADismantling core and coil assembly and cleaning of dust and dirt from the core assembly and checking of LV and HV leg coils for assessing its reuse, rechecking and recording of physical dimensions of coil and cleaning of core and their components etc.10KVA25KVA63KVA100KVAReconditioning of minor damaged in HV/LV leg coil/ Strip of transformer. work includes removing of damage part DPC insulation and providing new DPC on same HV coil/LV Strip should be properly cleaned and should be made of same size as of original .25KVA63KVA100KVA‘‘Making of complete LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.10KVA25KVA63KVA100KVA‘‘Making of complete HV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.10KVA25KVA63KVA100KVAAssembly of core and coils and fitting of other parts requiring replacement such as press board, making supports between adjacent sections by insulating spares and rapping etc & tapping etc. (Breezing/soldering) required, shall be arrange by the contractor.10KVA25KVA63KVA100KVAShifting and keeping the assembled core coil etc. in Oven from the repairing and assembly place.10KVA25KVA63KVA100KVATaking out assembled core and coils assembly from the OVEN and shifting to repairing hall.10KVA25KVA63KVA100KVARetanking of complete assembly into painted tank and lightening of the assembly in the tank safely. Fitting of all accessories of the transformer.10KVA25KVA63KVA100KVAWelding of repaired transformers including of top cover plate by electric core welding filling of gaps or fixing of top cover plate by properly nuts & bolts to prevent seepage of water..10KVA25KVA63KVA100KVAPainting of t/f outside with super enamel synethics paint of yellow color in two coats after providing primer of red oxide paint etc. paint & painting materials shall be provided by contractor.10KVA25KVA63KVA100KVADragging of repaired T/f upto the test cabin/testing place for testing and their re-dragging to yard and its stacking at indentified place after testing10KVA25KVA63KVA100KVATesting the correctness of connection, DVDF, No load, load loss test (where available), High Voltage, impedance voltage, Short Circuit and open circuit test, Voltage ratio on various tap position.10KVA25KVA63KVA100KVAPunching and welding of M.S. Plate on outside of transformer of size 100 mm x 50mm x 3 mm containing/ punching. (a) of unique number as decided by the department with a punch head. (b) Date of repair. 10KVA25KVA63KVA100KVA
Contract Date: Ref. Documents Contract Value : 50.73 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
40.
Power #10842171 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer-Handling and dragging of transformer from stacking yard to repairing hall.10KVACutting of Sealed transformers top cover plate smoothly and uniformally by gas/chisel cutter or opening of top cover plat and detanking of core and coil assembly.10KVADragging of the tank from the repaired hall to yard. & cleaning oil and dust etc. and scraping the rust etc and Washing of Transformer tank with Caustic Soda & water, Caustic soda shall be provided by contractor10KVAPainting of inner side of transformer tank and channels with heat proof zinc chromate paint of good quality (Berger, Nerolac, Jenson & Nicholson etc) shall be 10KVADragging out empty tank from yard to repairing hall.10KVADismantling core and coil assembly and cleaning of dust and dirt from the core assembly and checking of LV and HV leg coils for assessing its reuse, rechecking and recording of physical dimensions of coil and cleaning of core and their components etc.10KVA‘‘Making of complete HV/ LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.10KVAAssembly of core and coils and fitting of other parts requiring replacement such as press board, making supports between adjacent sections by insulating spares and rapping etc & tapping etc. (Breezing/soldering) required, shall be arrange by the contractor.10KVAShifting and keeping the assembled core coil etc. in Oven from the repairing and assembly place.10KVATaking out assembled core and coils assembly from the OVEN and shifting to repairing hall.10KVARetanking of complete assembly into painted tank and lightening of the assembly in the tank safely. Fitting of all accessories of the transformer.10KVAWelding of repaired transformers including of top cover plate by electric core welding filling of gaps or fixing of top cover plate by properly nuts & bolts to prevent seepage of water..10KVAPainting of t/f outside with super enamel synethics paint of yellow color in two coats after providing primer of red oxide paint etc. paint & painting materials shall be provided by contractor.10KVADragging of repaired T/f upto the test cabin/testing place for testing and their re-dragging to yard and its stacking at indentified place after testing10KVATesting the correctness of connection, DVDF, No load, load loss test (where available), High Voltage, impedance voltage, Short Circuit and open circuit test, Voltage ratio on various tap position.10KVAPunching and welding of M.S. Plate on outside of transformer of size 100 mm x 50mm x 3 mm containing/ punching. (a) of unique number as decided by the department with a punch head. (b) Date of repair. 10KVA
Contract Date: Ref. Documents Contract Value : 15.33 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
41.
Power #10842069 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer-2Handling and dragging of transformer from stacking yard to repairing hall.10KVA16KVA25KVA63KVACutting of Sealed transformers top cover plate smoothly and uniformally by gas/chisel cutter or opening of top cover plat and detanking of core and coil assembly.10KVA16KVA25KVA63KVADragging of the tank from the repaired hall to yard. & cleaning oil and dust etc. and scraping the rust etc and Washing of Transformer tank with Caustic Soda & water, Caustic soda shall be provided by contractor10KVA16KVA25KVA63KVAPainting of inner side of transformer tank and channels with heat proof zinc chromate paint of good quality (Berger, Nerolac, Jenson & Nicholson etc) shall be 10KVA16KVA25KVA63KVADragging out empty tank from yard to repairing hall.10KVA16KVA25KVA63KVADismantling core and coil assembly and cleaning of dust and dirt from the core assembly and checking of LV and HV leg coils for assessing its reuse, rechecking and recording of physical dimensions of coil and cleaning of core and their components etc.10KVA16KVA25KVA63KVA‘‘Making of complete HV/ LV leg Alu. Leg coils identical to original one with same number of turns, weight etc providing super enameled / DPC conductor/ Strip confirming to IS 1971 /53 in place of old and damage coil. Alu. coil, wire strip will be provided by the department. All coil assembly of identical voltage shall be interchangeable without requiring any special equipment. Coil shall be supported between adjacent sections by insulations, spacers, beamers and other insulations.Rewinding shall be arranged to ensure free circulation of oil to reduced hot spots in winding. The insulation of coil shall be treated with suitable insulating, varnish or equivalent compound to develop the full electrical strength of winding as per original design.10KVA16KVA25KVA63KVAAssembly of core and coils and fitting of other parts requiring replacement such as press board, making supports between adjacent sections by insulating spares and rapping etc & tapping etc. (Breezing/soldering) required, shall be arrange by the contractor.10KVA16KVA25KVA63KVAShifting and keeping the assembled core coil etc. in Oven from the repairing and assembly place.10KVA16KVA25KVA63KVATaking out assembled core and coils assembly from the OVEN and shifting to repairing hall.10KVA16KVA25KVA63KVARetanking of complete assembly into painted tank and lightening of the assembly in the tank safely. Fitting of all accessories of the transformer.10KVA16KVA25KVA63KVAWelding of repaired transformers including of top cover plate by electric core welding filling of gaps or fixing of top cover plate by properly nuts & bolts to prevent seepage of water..10KVA16KVA25KVA63KVAPainting of t/f outside with super enamel synethics paint of yellow color in two coats after providing primer of red oxide paint etc. paint & painting materials shall be provided by contractor.10KVA16KVA25KVA63KVADragging of repaired T/f upto the test cabin/testing place for testing and their re-dragging to yard and its stacking at indentified place after testing10KVA16KVA25KVA63KVATesting the correctness of connection, DVDF, No load, load loss test (where available), High Voltage, impedance voltage, Short Circuit and open circuit test, Voltage ratio on various tap position.10KVA16KVA25KVA63KVAPunching and welding of M.S. Plate on outside of transformer of size 100 mm x 50mm x 3 mm containing/ punching. (a) of unique number as decided by the department with a punch head. (b) Date of repair. 10KVA16KVA25KVA63KVA
Contract Date: Ref. Documents Contract Value : 13.59 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
42.
Power #10842062 AOC
Bids Are Invited For Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - As Per Rfp; As Per Rfp; Buyer-Handling And Dragging Of Transformer From Stacking Yard To Repairing Hall. 10Kva 16Kva 25Kva Cutting Of Sealed Transformers Top Cover Plate Smoothly And Uniformally By Gas/Chisel Cutter Or Opening Of Top Cover Plat And Detanking Of Core And Coil Assembly. 10Kva 16Kva 25Kva Dragging Of The Tank From The Repaired Hall To Yard. & Cleaning Oil And Dust Etc. And Scraping The Rust Etc And Washing Of Transformer Tank With Caustic Soda & Water, Caustic Soda Shall Be Provided By Contractor 10Kva 16Kva 25Kva Painting Of Inner Side Of Transformer Tank And Channels With Heat Proof Zinc Chromate Paint Of Good Quality (Berger, Nerolac, Jenson & Nicholson Etc) Shall Be 10Kva 16Kva 25Kva Dragging Out Empty Tank From Yard To Repairing Hall. 10Kva 16Kva 25Kva Dismantling Core And Coil Assembly And Cleaning Of Dust And Dirt From The Core Assembly And Checking Of Lv And Hv Leg Coils For Assessing Its Reuse, Rechecking And Recording Of Physical Dimensions Of Coil And Cleaning Of Core And Their Components Etc. 10Kva 16Kva 25Kva ‘‘Making Of Complete Hv/ Lv Leg Alu. Leg Coils Identical To Original One With Same Number Of Turns, Weight Etc Providing Super Enameled / Dpc Conductor/ Strip Confirming To Is 1971 /53 In Place Of Old And Damage Coil. Alu. Coil, Wire Strip Will Be Provided By The Department. All Coil Assembly Of Identical Voltage Shall Be Interchangeable Without Requiring Any Special Equipment. Coil Shall Be Supported Between Adjacent Sections By Insulations, Spacers, Beamers And Other Insulations.Rewinding Shall Be Arranged To Ensure Free Circulation Of Oil To Reduced Hot Spots In Winding. The Insulation Of Coil Shall Be Treated With Suitable Insulating, Varnish Or Equivalent Compound To Develop The Full Electrical Strength Of Winding As Per Original Design. 10Kva 16Kva 25Kva Assembly Of Core And Coils And Fitting Of Other Parts Requiring Replacement Such As Press Board, Making Supports Between Adjacent Sections By Insulating Spares And Rapping Etc & Tapping Etc. (Breezing/Soldering) Required, Shall Be Arrange By The Contractor. 10Kva 16Kva 25Kva Shifting And Keeping The Assembled Core Coil Etc. In Oven From The Repairing And Assembly Place. 10Kva 16Kva 25Kva Taking Out Assembled Core And Coils Assembly From The Oven And Shifting To Repairing Hall. 10Kva 16Kva 25Kva Retanking Of Complete Assembly Into Painted Tank And Lightening Of The Assembly In The Tank Safely. Fitting Of All Accessories Of The Transformer. 10Kva 16Kva 25Kva Welding Of Repaired Transformers Including Of Top Cover Plate By Electric Core Welding Filling Of Gaps Or Fixing Of Top Cover Plate By Properly Nuts & Bolts To Prevent Seepage Of Water.. 10Kva 16Kva 25Kva Painting Of T/F Outside With Super Enamel Synethics Paint Of Yellow Color In Two Coats After Providing Primer Of Red Oxide Paint Etc. Paint & Painting Materials Shall Be Provided By Contractor. 10Kva 16Kva 25Kva Dragging Of Repaired T/F Upto The Test Cabin/Testing Place For Testing And Their Re-Dragging To Yard And Its Stacking At Indentified Place After Testing 10Kva 16Kva 25Kva Testing The Correctness Of Connection, Dvdf, No Load, Load Loss Test (Where Available), High Voltage, Impedance Voltage, Short Circuit And Open Circuit Test, Voltage Ratio On Various Tap Position. 10Kva 16Kva 25Kva Punching And Welding Of M.S. Plate On Outside Of Transformer Of Size 100 Mm X 50Mm X 3 Mm Containing/ Punching. (A) Of Unique Number As Decided By The Department With A Punch Head. (B) Date Of Repair. 10Kva 16Kva 25Kva
Contract Date: Ref. Documents Contract Value : 38.89 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
44.
Defence #10801071 Price Bid
Tender For Comprehensive B R And Em Repair Maintenance Works To 14 Asc Af Kakkanad Under Age I R D Kochi; 1 Hacking out old broken glass panes 4 mm thick from steel frame including putty/ metal beadings and supply and fix sheet glass ordinary 4 mm thick, in squares n.exc. 0.50 Sqm in each pane including necessary new oil putty or with existing metal beadings complete all as specified and as directed 2 Hacking out old broken glass panes 4 mm thick from wooden framed shutters including putty/wooden beadings and supply and fix sheet glass ordinary quality, 4 mm thick, in square n.exc. 0.5 Sqm in each pane including necessary oil putty/wooden beads complete all as specified and as directed. 3 S&F in repairs extruded aluminium anodised 150 mm long handles fabricated type. 4 All as per item No 3 above but 100 mm long. 5 Supply and fix in repairs foot operated door stopper of aluminium alloy body and tongue anodised with hard drawn steel spring and cover plate overall length 150 mm including taking down defective foot operated door stopper all as specified and as directed. 6 S&F in repairsmortice lock brass 4 levers vertical type 100 mm 7 S & Fin repairs door closer hydraulically regulated, castiron body, designation No -3, universal type ,suitable for door shuttersof 851 to1000 mm in width and of wt between 61 to 80 Kg and fixed 8 Re securing and easing to wooden shutters of any description area n.exc 1 Sqm each without taking down the shutter all as specified and as directed. 9 Re securing and easing to wooden shutters of any description exc 1 Sqmbut n.exc 2 Sqm each without taking down the shutters all as specified and as directed. 10 S&F In repairs Aluminium anodised, barrel tower bolts of extruded section 150 mm long. 11 All as per item No 10 above but 100 mm long. 12 S&F in repairs Aluminium alloy, anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts of extruded sections or cast-aluminium alloy, 300 mm long 13 Taking down shutters exc 1 sq. m and n exc2 sq. m each and re-fixing in same openings. 14 Taking down shutters n exc 1 sq. m each and re-fixing in same openings. 15 S&F in repairs Butt hinges, medium weight cold rolled mild steel 100 mm size. 16 All as per item No 15 above but 75 mm size. 17 Taking down and removing to or from store chowkats or framesexc 1.5 sq. m and not exc 4 sqm each but with shutters (without taking off shutters from the frames) 18 S&F Solid PVC door frame of size 50mm x 47mm made of of 5mm plain color PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing. 19 S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top and bottom rails. M.S. frame shall be covered with heat moulded plain color PVC C channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain color PVC sheets for top rail, lock rail &bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain color PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing. 20 S&F Aluminium, anodised, barrel tower boltsof extruded section and fixed length of bolt in 200 mm complete all as specified and directed. 21 S&F Butt hinges, medium weight, cold rolled mild steel, and fixed size of hinges in 100 mm complete all as specified and directed. 22 S&F Aluminium handles, cast type, anodised size of handle in 150mm 23 Supply and fix in repair PVC low level flushing cistern 10 liters capacity with ISI mark including inlet, ball valve, float, handle and brackets etc. including taking down old defective low level flushing cistern all as specified and as directed. 24 Supply and fix plastic seat and cover superior quality closed pattern with flat bottom of heavy duty including necessary hinged devices, including taking down damaged/ broken plastic seat and cover from EWC all as specified and as directed. 25 Supply and Fix in repair PVC connection with PTMT nuts of length 450 mm screwed for iron pipe15 mm bore. 26 Supply and fix in repair 15 mm dia CP pillar cocks fancy type for wash hand basin including taking down existing pillar cock, all as specified and as directed. 27 Supply and fix 150 mm square grating of PTMT to floor trap/nahani trap including taking down existing damaged CI grating from floor tap/nahani trap all as specified and as directed. 28 Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store 15mm bore pipe, all as specified and as directed. 29 All as per item No 28 above but 20mm bore. 30 All as per item No 28 above but 25/32 mm bore. 31 Supply and fix Unplasticised PVC pipes of bore 15mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 32 Supply and fix Unplasticised PVC pipes of bore 20mm, pressure rating 10 Kg/Sq. Cm pressure rating 10 Kgf/Sq. Cm all as specified and as directed 33 Supplying and laying of CPVC pipes 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. 34 S&F in repairs bib taps 15mm bore, cast copper alloy chromium plated with crutch or butterfly handle, fancy type, screwed for iron pipe or for brass ferrule all as specified and as directed 35 S&F in repairs stop valves 15mm bore, cast copper alloy chromium plated fancy type, screwed down high pressure, with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed. 36 S&F in repairs vitreous china wash basin white flat back, size 580x450mm excluding taps waste, chain and plug and porcelain stopper including brackets all as specified and as directed. 37 S&F in repairs vitreous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe). 38 Supply and fix tubular towel rail aluminium anodised20 mm dia D type 60 cm long between flanges including taking down defective aluminium tubular towel rail all as specified and as directed. 39 Supply and fix in repair beveled edgedmirror of size 600 x 450 mm selected quality glass mounted on 6mm thick AC building board or commercial ply wood and fixed to wooden plugs with chromium plated brass screws and cup washers all as specified and directed. 40 S&F PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore. 41 All as per item 40 above but 110 mm bore 42 S&F PVC (SWR) bends any radius 75 mm bore 43 Supply and fix in repairs 100 mm dia CIfloor trap/nahani trap including taking down existing damaged CI grating from floor trap/nahani trap 44 M&L Dismantling water tanks and removing to store exc 250 & n exc 500 capacity 45 M&L Dismantling water tanks and removing to store exc 500 & n exc 1000 capacity 46 M&L Rotational moulded polyethylene water storage tanks 500 litres capacity(cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia PTMT Ball valve high pressure all as directed. 47 Allas per item No 46 above but 1000 ltr capacity 48 M & L for PU injection grouting by making necessary holes of 8 to 10 mm in concrete to a depth of about 75mm using proper electric hammer drill. Fix new nipples of 8 to 10mm using aluminum pipes using neat cement or M-Seal for proper anchorage. Carry-out pressure grouting using shaligrout 2k /equivalent) using a proper grouting pump. Seal the holes properly after the grouting nipples have been removed all as specified and directed by Engg -In Charge. 49 Material and labour for taking down old plaster and rendering 10mm thick in CM 1:6 on other than fair faces of brickor concrete surfaces finishing smooth and even and smooth without using extra cement making good match the old surface finish. 50 M&L two coat of OBD over a coat of primer on newly plastered surfaces of wall including cornices and preparation of surfaces. 51 M&L pre laminated particle board 12mm thick interior grade pre laminated one side with decorative choice lamination and other side balancing white lamination fixture with screws to frame work 52 Dismantling floor, hearth or wall tilling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge 53 M&L Screed bed or bedding layer 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by Engineer-in-Charge 54 M&L Rendering 10 mm thick in CM 1:3 on brick or concrete surfaces, finished fair and even for receiving wall tiles. 55 S&F glazed ceramic coloured tiles 300 x 200 x 7 mm thickon vertical surfaces, set and jointed in neat cement slurry and pointed in white/colour cement to match over 10 mm thick rendering (backing coat)in cm 1:3, complete all as specified and directed by Engineer-in-Charge. 56 M & L for non-skid ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 sqm but not exceeding 0.11 sqm In floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge 57 S&F Vitrified ceramic coloured tiles 10mm thick (Square/ Rectangular) polished area of each tile not exceeding 0.36 Sqm in floors set and jointed in neat cement slurry and pointed in white or coloured cement to match 58 S&F in repairs health faucet 15mm size chromium plated standard size all as specified and directed. 59 Supply and fixed in repairs stainless steel wire cloth, 0.63mm nominal dia of wire and average width aperture 1.40mm and fixed with tinned tacks, or galvanized wire staples 60 M&L for chip and remove all damaged and de bonded concrete and plaster from the RCC slabs by manually or mechanically so as to expose the corroded reinforcement bars, removingthe debris with in a lead of 100 meters as directed by Engineer-in-charge. 61 M&L for supply and application of Nitobond EP (Manufactured by M/s Fosroc chemicals India Ltd) epoxy bonding agent over the old concrete surface complete all as specified and all as directed by Engineer-in-charge. 62 M&L for supply and application of rust remover/converter (Rebaklense RR of M/s Fosroc Chemicals India Ltd. or equivalent) or Amandur ,(manufactured by GK technocom) over the corroded reinforcement bar where ever micro concreting is required and cleaning the same after application complete all as directed by Engineer-in-charge. 63 M&L for plastering with Nitobond SBR (Styrene butadiene polymer bonding agent cum cement mortar/concrete modifier Manufactured by M/s Fosroc Chemicals India Ltd or equivalent) modified cement mortar (1:4) under the slab to an average thickness of 40 mm (applied in two layers not exceeding 20mm each) , including the cost of all materials rent of tools and labour charges etc complete all as directed by Engr-in-charge. 64 M&L Preparation of newsurfaces of ceiling and applying two coats of distemper oil emulsion on ceiling over a coat of primer over 3 mm thick wall care putty plastered and other surfaces with alkali resistant priming paint complete all as specified. 65 Taking down cement plaster of any description on walls incl raking out joints, hacking for key scrubbing down with water 66 M&L for plastering in CM1:6, 10 mm thick on interior walls finished even and smooth w/o using extra cement. 67 M&L for plasteringin CM 1:3, 5mm thick on ceiling finished even and smooth w/o using extra cement 68 M&L for two coats of Antifungal paint (Apex ultima Protek of Asian paint or Equivalent in approved Makes) over a coat of Exterior primer (Professional pack of Asian paints) over a coat of external wall care putty n.exc 2 mm thick on new or old prepared plastered external surfaces . 69 M&L Preparation of Newsurfaces of internal walland applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 70 M&L Preparation of oldsurfaces of internal wall by complete removal of existing treatment , and applying two coats of distemper oil emulsion on wall over a coat of primer plastered and other surfaces with alkali resistant priming paint over 3mm thick wall care putty complete all as specified. 71 M&L Preparation of old surfaces of ceiling by complete removal of existing treatment, and applying two coats of distemper oil emulsion on ceiling over a coat of primer, plastered and other surfaces with alkali resistant paint complete all as specified. 72 Demolition of brick work / PCC block masonry work built in cement mortar etc complete all as specified. 73 M&L Precast Concrete block masonry with solid blocks in PCC 1:3:6 type C1 (using 20 mm stone agg) exc 10 cm in width and setting in mortar 1:4with minimum compressive strength of 5N/ sq mm complete all as specified and as directed. 74 M&L for providing and fixing Gypsum Board 12mm thick in walls fixed with screw as per manufacturer’s instructions complete all as specified. 75 Dismantling in Wall and ceiling boards (fiber, pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness, including cover fillets complete all as specified. 76 M & L Anodised aluminium snap grid frame work (size of grid 605x 605) mm for false ceiling including Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified all as specified and as directed. 77 M&L for providing and fixing Exposed metal frame ceiling with fire resistant calcium silicate board of siliceous and calcareous material reinforced with cellulose fiber for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paid separately) fixed with screw as per manufacturer’s instructions complete all as specified. 78 Cleaning (mechanically)of sewage line/effluent drains 150/110 mm dia and disposing offthe sludge outside MoD land complete all as directed. 79 Removing the chokes in drains of WC/bath room/kitchen up to 1st manhole including cleaning of gully traps in single storey/ground floor of multi storeyed buildings, all as specified and directed. 80 Removing chokes in drains of WC/bath room/kitchen other than ground floor all as specified and directed. 81 Destruction of growth of weed plants with roots level on wall/ roof of building any height with weedicides such as Round up manufactured by Excel Chemical Industries and sprayed in and around roots and the place of possible growth of weeds as per manufacturer’sinstructions and making good the surfacescomplete all as specifiedand as directed. 82 Demolition of reinforced cement concrete in any position not otherwise specifically provided for 83 M& L for Precast RCC Cover slabs type B-1, 1:2:4 (20 mm graded stone aggregate as in slabs of drains including necessary form works. (Reinforcement bar will be measuredand paid separately). 84 M&L TMT bars 10mm dia and over cut to length bent to shape required, including, cranking, bending spirally for hooping for columns hooking ends and binding with mild steel wire (annealed ) not less than 0.9mm dia or securing with clips 85 Demolition of cement concrete in any position not otherwise specifically provided for complete all as specified and directed. 86 M & L for 1:3:6 Type C-2 (using 40 mm graded stone aggregate) for surface channels anddrains all as specified 87 Extra for forming fair finished drain or channel 30 Cminner girth in cement concrete ,using extra cement, including forms, moulds, mitered /stopped endsetc 88 Opening manhole of septic tank remove night soil and sediments including liquid by mechanical pumping into tanker lorry having cleaning internal surface with water and re-fix the manhole covers, complete all as specified and directed. Notes :-(i)Volume of the manhole will be worked out based on the depth or actual depth of sludge, whichever is less.(ii) Water shall be procured by the contractor for cleaning purpose. 89 Demolition of cement concretein ground floors and pavings n.exc 15 cm thickness (below or above ground level) 90 M&L for 100mm thick PCC ( 1:3:6)type C-2,using 40mm graded stone aggregate as in hard standing/path/sub basefinished to an even and fair surfaces. 91 M&L forming contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade A. 92 Dismantling structural steel work incl doors, gates but excluding framed trusses. 93 S & FMS work in railings, balusters, posts and struts in fencing etc including cutting tops to shapeas directed, includingall necessary welding, drilling bolting or riveting etc and similar work conforming to FE 290 Gd E-165 complete all as specified 94 S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc. complete drilled for fixing of steel sheeting or other covering.Doors etc to be prepared for hanging with and including hooks and hinges, also fastening and fixing complete conforming to Fe-410W (Gde-E-250) 95 M&L for Point wiring for light point /fan point/Exhaust fan /Bell Pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class PVC conduit, with modular switch, modular plate and cover with GI box and earthing the point with 1.5 sq.mm FRLS PVC insulatedcopper conductor single core cable etc. including dismantling /removing of burnt cable/making good surface asrequired . 96 M&L for submain wiring for 5 Amp socket outlet point on independent board with 2x 1.5 sqmm single core PVC insulated and unsheathed FRLS cable, 1100 volts grade IS -694 marked with multi standard copper conductors and earth continuity wire with similar 1x1.5 sqmm cable (incl connecting to earth dolly) drawn through and single core cable in surface/recessed medium class PVC conduit including dismantling /removing of burnt cable/making good surface as persiterequirement . 97 Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular switch and 5/6A modular socket ,connection etc. as required atsitecomplete all as specified and directed (for Independent 5 Amp socket ) . 98 M&L for wiring for circuit along with 2.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed steel conduit as required .wire 2x22.5 sq.mm + 1x2.5 sq.mm earth wire for 15/25 power plug/socket. 99 All as per item above but Supply and fixingsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 15/16 A modular switch and 15/16A modularsocket ,connection etc. as required atsitecomplete all as specified and directed( for 15/16 Amp Socket ). 100 M&L for wiring for circuit along with 4 sq.mm FRLS PVC insulated copper conductorsingle core cable in surface /recessed steel conduit as required .wire 2x4 sq.mm + 1x4 sq.mm earth wire (for Ac & Geyser ) 101 S&F Electronic ceiling fan regulator, modular type stepped /socket type heavy duty suitable to work on 230 volts complete all as specified and directed. 102 Supply & Fixing piano type 5/6 amps switch on the existing Switch box including connection as required on site. 103 Supply & Fixing piano type 2 way 5/6 amps switch on the existing Switch box including connection as required on site. 104 Supply & Fixing piano type 15/16 amps switch on the existing Switch box including connection as required on site. 105 Supply & Fixing piano type 3 pin 5/6 amps socket outlet switch on the existing Switch box including connection as required on site. 106 Supply & Fixing piano type 6 pin 15/16 amps socket outlet switch on the existing Switch box including connection as required on site. 107 Supply & Fixing 5/6 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 108 Supply & Fixing 15/25 Amodular switch on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 109 Supply & Fixing 3 pin 5/6 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 110 Supply & Fixing 6 pin 15/25 modular socket on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 111 Supply & Fixing modular bell push on the existing modular plate & Switch box including connection but excluding modular plates etc. as required on site. 112 Supply and fixing 1 or 2 module base & cover plate on existing modular metal boxes etc as required. 113 Supply and fixing 3 module base & cover plate on existing modular metal boxes etc as required. 114 Supply and fixing 4 module base & cover plate on existing modular metal boxes etc as required. 115 Supply and fixing 6 module base & cover plate on existing modular metal boxes etc as required. 116 Supply and fixing 8 module base & cover plate on existing modular metal boxes etc as required. 117 Supply and fixing LED light fitting 1X20W,220V high efficiency(efficiency up to 100lm/w) polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-20-30/40/65-SL-DP-NWHor GM/ Panasonic/Havells etc. 118 Supply and fixing LED light fitting 1X10W,220V high efficiency(efficiency up to 100lm/w)polycarbonate batten bright light having high quality material and design, compact appearance simple and versatile in nature makes it as long lasting efficient solution, Make Crompton, Product code : CCS-102-10-30/40/65-SL-DP-NWH or Havells /Panasonic/GM etc. 119 S & F in repairs LED 20W T8 Tube within built driver and efficiency of 100lm/w having glare free lighting distribution, double sided connection, housing made of high grade polycarbonate cover, 2.5 KV internal surge protection, IP20 ingress protection, PCB mounted on extruded metal plate. Make: Crompton model No LT8-20-865-(2) or equivalent in Havells/C&S/ Phillips/Bajaj. 120 S&F switch socket combination 5 Amp with PVC box suitable for 230 Volt on surface. 121 S&F switch socket combination 15 Amp with PVC box suitable for 230 Volt in surface 122 M&L switch socket combination2 in 1, 6/16 Amp flush type in existing switch box. 123 All as per item above but 6 Amp flush type in existing switch box. 124 M&L forbell AC 230 V Single pole ding dong type. 125 Supply and fixing angular type batten holder insulator body of PVC/ polycarbonate type suitable for 10/9 W Led bulb. 126 Supply and fixing fan condenser / capacitor of size 2.25/2.5 suitable for ceiling fan of any sweep. 127 Supply and fixingonly LED lamp of 9 watt, Make : Crompton/ Havells /Panasonic 128 S&F of 20 Amps 240 V , SPN Industrial type socket outlet, with 2 pole and earth ,metal enclosed plug top along with 20 A C Curve ,SP MCB , in sheet steel enclosure ,on surface or in recess with chained metal cover for the socket outlet and complete with connections ,testing and commissioning etc. as required . 129 Supplying and fixing 6 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) 130 Supplying and fixing 8 way, Double door single pole and neutral sheet steel, MCB distribution board,240 V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar ,din bar interconnections, powder painted including earthing etc. as required (But without MCB / RCCB/Isolator) 131 Supplying and fixing 4 way, Horizontal type , Three pole and neutral Dl sheet steel, MCB distribution board, 415V, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/ RCCB/ Isolator) 132 Supply and fixing of 5A to 32 A rating, 240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole in the existing MCB DB Complete with connections, testing and commissioning etc ax required. 133 Supply and fixing of 5A to 32 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of single pole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc ax required. 134 Supply and fixing of 63 A rating,240/415V, 10kA C curve miniature circuit Breaker suitable for inductive load of Triplepole and neutralin the existing MCB DB Complete with connections, testing and commissioning etc as required. Make: IndoAsain, HSN Code: 8536, Cat. Nos.: 810107 or equivalent make of LT/ Havells. 135 M & L LED Square surface mounted Led Panel 12w, PDC housing and high translucent frosted plastic diffuser makes it a robust Luminar and efficiency up to 100lm/w. Make: Crompton, Model no LCDSPLN-R-12-CDL or equivalent make of GM/Havells. 136 M & L LED Round and Square recess mounted 12w LED edge lit slim down light with die cast aluminium housing finished in premium white coating and efficacy up to 100lm/w suitable for false ceiling. Make Crompton, Model no LSCRM-12W-WW/NW/ CDL or equivalent make of GM/Havells. 137 Dismantling and taking down ceiling fan any size for servicing by cleaning dust, filling cavities with filler and painting complete with synthetic enamel paint by spraying and re fixing the same in position, connecting and testingall as specified and directed. 138 M & L for carry out rewinding of ceiling fan motor of any size/ make including taking down from any height ,dismantling ceiling fan motor , removing old burnt winding wire, cleaning the armature thoroughly and replacing the same with new enameled copper wire of adequate size/gauge including class B insulation, varnishing heating etc, reassembling and removing the old painting and providing newpainting to ceiling fanscompletewith synthetic enamel Grey paintby spraying using machine including filling cavities with filler one coat after cleaning all dust making the surface in good finishes etc , testing, re-fixing the same in original position complete all as specified and as directed by the Engineer - in - Charge.Note: Rate include the taking down the ceiling fan and deposited to MES store for checkingand repairing) 139 All as per Item above but for the Exhaust fan of 300 /450 mm sweep sizes: 140 S & F in repairs of LED 36W surface full lit luminaire with glare free uniform illumination with longer life and less maintenance available in 2x2 ft (> 100 lm/w).Make: Crompton, Model No LCTLSNE-36-FO-WW/TL/CDL or Havells /C&S/ Phillips/Bajaj. 141 Supply andLayingGI tubing medium grade of size 50 mm with and including all fittings such as bends, elbows, tees, short pieces etc complete in trenches of following sizes after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. Note- Excavation & earth work will be measured & paid separately. 142 All as per item above but 40 mm bore 143 All as per item above but 25 mm bore 144 Supply & Fixing of Size 50 mm GI tubing medium grade withand including all fittings such as bends, elbows, tees, short pieces etc complete on wall and ceiling or laid in floors after taking down old unserviceable GI pipes all as specified and directed by Engr in charge. 145 All as per item No 4 above but 40 mm bore 146 All as per item No 4 above but 25 mm bore 147 All as per item No 4 above but 20 mm bore 148 Repairs to leakage /damaged G.I. pipe of size 50/40 mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples ,Bends etc. all asdirected by Engr- in- charge. Note:- G.I. pipe length will be measured and paid separately under relevant item of sch A 149 All as per item above but 25/20 mm bore 150 Supply and fix in repairs gun metal gate valve of size 50 mm ISI marked with iron wheel head screwed both ends all as directed. 151 All as per item above but 40 mm bore 152 All as per item above but 25 mm bore 153 All as per item above but 20 mm bore 154 All as per item above but 15 mm bore 155 S&F in repairs un plasticized PVC pipe, 25mm bore of pressure rating 10 Kg/ Sqcm with all fittings, fixed to walls, ceilings or in floors complete with snap clips hooks etc and taking out old unserviceable one all as specified an as directed 156 All as per item above butof size 20 mm bore dia 157 Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth and getting out in soft / loose soil forlaying/taking out GI pipe line all as specified and directed. 158 Returning filling in including spreadingleveling watering and well rammingin layer not exceeding 25 cm in soft/loose soil all as specified and directed. 159 Removing excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mabove the starting point all as specified and directed. 160 M & L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside of the RCC Under Ground Sump of10,000 Ltrscapacity by dewatering the sump and cleaning the complete inner surfaces by rubbing / scrapping by wire brush to removethe sludge, washing with bleaching powder solution and then with water and draining out sludge, water completely including applying one coat of white wash to all the inner surfaces, and details of tanks like date of cleaning ,capacity of tanks etc shall be written on the outside of the tank with synthetic enamel paint with lettersize 20 cm high in white color , over a black backgroundof size 100x60 cmand charges included for pump set for de watering incl operator all as specified anddirected 161 M&L for removing the dirt, sediments, silt, algae, fungi etc, from the bottom and walls of the inside PVC Service tanks kept on roof top of buildings or on stagings, cleaning the surface using brush and other cleaning materials such as bleaching powder as required including writing the capacity of the tank and date of cleaning with white enamel paint over black back ground all as specified and directed for the following capacity of tanks at different locations on Technical/Residential Buildings all as specified and directed by Engr-in-Charge. 162 2000 Ltr capacity 163 1000 Ltr Capacity 164 500/300 Ltr capacity 165 S&F in repairs float Valve 40mm bore (Ball brass valves) high pressure type with polyethylene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed and taking out old unserviceable one all as specified and directed 166 All as per item above but of size 25mm bore 167 All as per item above but of size 20mm bore 168 S&F in repair/replacement HDPE Tank cover suitable for 300 to 1000 Litr capacity and taking out old unserviceable one 169 All as per item above but for 2000Ltr capacity tanks 170 M&L for repair/replacement ofFoot valve of size 50mmbrass heavy duty including taking up the suction pipe and re-fixing the same after replacement of foot valve in to the sump for proper functioning of pump and taking out old unserviceable one all as specified and directed 171 Dismantling of Mono-block Pump set from the existing position for servicing including opening the pump replacing the unserviceable ball bearings of suitable size for capacities up to 5 HP including greasing complete all as specified and directed 172 Repairs and servicing of Electric chlorine dozing Pump/ system Make Sathya sai Aqua Pura Services with Ant siphon valve including servicing of pump and motor with repair/ replacement of unserviceable parts like piston, stroke controller, suction and delivery tubing, PVC foot valve, nozzle, solution tank inlet, PVC water tubing 15mmbore, gate valve 15mm size etc, complete all as specified and directed. 173 M&L for cleaning of pump sets starter panel after dismantling the incoming and outgoing connections from MCCBs /MCBs and replacing the old unserviceable gland, lugs, nuts &bolts, push buttons, indicating lamps, supporting insulators etc, and checking the serviceability of MCBs cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed 174 M&L for Replacement of unserviceable DOL Starter suitable for motor up to 5 HPincluding connections 175 M&L for Repairing the old Valve pit of dimension 60x45x45 cm by taking out plaster and rendering with 10mm thick CM(1:4) including PCC (1:3:6) TYPE C2 on base, brick work inCM (1:4) as required and applying two coats of white wash on plastered surface including applying two coats of synthetic enamel paint over one coat of red oxide primer over steel surfaces after preparation, complete all as specified and directed 176 M&L for painting pump set including preparation old surfaces and painting with two coats of synthetic enamel paint over a coat of red oxide primer including marking the signs, letters, Nos on the pump setof capacity up to 2HP all as specified and as directed. 177 M&L for painting of old painted GI pipe of any size on the external surfaces after preparation, located in and out of Pump House, by scrapping and cleaning of external surfaces and applying two coats of Sky Blue paint over a coat of red oxide primer complete all as specified and directed. 178 Dismantling , taking out complete burnt winding wire of submersible motor including cleaning of statorslots replacement of defective parts and rewinding with existing type & gauge ofcopper wireas per motor capacity and using new insulation material such as insulating paper sleeves etc. replacement of submersible cable as required length complete all as directed of rating 1.5/2HP Single phase 179 Repairs to leakage /damaged G.I. pipe of size 80 to 100mm bore including necessary excavation, returning, filling in removal/ pump out the line water cutting out GI pipes at both ends replacement ofGI Pipe and jointing with new fittings accessories such assockets, tees, reducers, Nipples, Bends etc. all asdirected by Engr- in- charge. Note:- (i) G.I. pipe length will be measured and paid separately under relevant item of sch A 180 Material Labour for fixing Mechanical joint suitable 80 mm dia GI pipe, fabricated and made out of MS sheet of thickness 6/8 mm including welding work, rubber gasket, nuts, bolts and washers complete all as specified and directed by Engr in charge. 181 Comprehensive Maintenance, Servicing and carrying out periodical service to DG set along with AMF panel or standard panel like carry out oil service and routine checkup/maintenance as per manufacturers schedule, checking complete system of lubrication, cooling systems, air intake systems, fuel systems, exhaust systems, DC/AC electrical systems in DG Set as well as in AMF/Standard Panel, tightening bolts and nuts in engine and alternator related systems, etc and repairs including material for renewal/ replacement of minor defective parts of like connectors, MCBs , phase indication lamps etc for following capacity of DG sets all as specified and directed by Engr in charge. 182 35 KVA with AMF Panel installed at 14 ASC, AF Kakkanad 183 20 KVA with AMF Panel installed at 14 ASC 184 Note:The spares to DG Sets items as listed below as SUPPLY ONLY will be used whenever required only and it shall measured and paid separately under respective items. 185 The rate is inclusive of all items as required at site except those items as SUPPLY ONLY below to keep the DG Set along with AMF / Standard panel on monthly basis complete all as specified and as directed by Engr-in-Charge. 186 The contractor should attend any complaint / breakdown immediately on call basis and even no. of times without any extra cost. 187 Contractor should submit the inspection / maintenance report of every visit in spite of no of visits during breakdown calls including mentioning the status of DG Sets and spares any replaced 188 The old unserviceable spares replaced under comprehensive maintenance i.e. in sl No 02 of above BOQ is the property of contractor for which credit shall be deducted under respective items in schedule of credit. 189 All AMF panels and standard DG set panels should be well cleaned with CTC solution checking all the electrical connection and tighten for any loose connection. 190 Supply and replace of heavy duty diesel engine oil of 20W40 grade for DG Sets having capacities varying from 15 KVA to 35 KVA complete all as specified and as directed. 191 Supply only Lub Oil Filter for DG set 15 KVA to 35 KVA 192 Supply only fuel filter forDG set 15 KVA to 35 KVA 193 Supply only Oil pressure gauge for DG set of any size/make 194 Recharging of Battery 12 Volts , up to180 AH any make / type by replacing electrolyte including replacement of unserviceable terminal posts , to the required standard complete all as specified andas directed . 195 Diesel hose of size 5/16 all as directed 196 Battery terminals one end socket and the other end clamp type including brazing work and applying jelly over the battery terminal and pole all as directed by the Engr in charge 197 Water hoses complete set of engineDG sets of cap 15 to 35 KVA 198 Repairs to 12 V self starter of DG set engine by dismantling, removing and replacing the old defective/worn-out bearings, servicing including replacement of carbon brush, bendix drive, cleaning commutator in armature etc assembling and testing for satisfactory function all as directed. 199 Supply only auxiliary contactor suitable for AMF panel of 15 to 35 KVA DG set 200 Supply only power contactor suitable for AMF Panel of 15 to 35 KVA DG set 201 Supply, install, testing & commissioning in repairs DC relay card/ PLA relay 12/24 volt DC for DG set any capacity including making all electrical connections and checking by running the DG set for 02 hours complete all as specified and directed by Engr-in Charge, 202 Supply and mixing water coolant in radiator water of DG Sets having capacities varying from 15 KVA to 320 KVA complete all as specified and as directed. 203 Repairs to door of acoustic enclosure of DG set cap 20 KVA by taking down and replacing the door hinges and door lock including all M&L and as directed. 204 Supply only distilled water into battery capacity of 12/24 Volt 88/90/180 AH all as specified and as directed by Engineer-in-Charge. 205 Taking out old burnt out Automatic voltage regulator from DG setcapacity 15 KVA to 35 KVA alternator and replace with new AVR and includingtesting and checking voltage regulation ofthe DG set on full loadfor its satisfactory performance complete all as specified and directed by Engineer-in-Charge:- 206 M&L for dismantling of complete radiator assy for DG Set capacity 15KVA to 35 KVA from engine and taking out all, de scaling rusty, sludge and muddy particles inside the radiator by using of sodium hydroxide with water pressure cleaning complete, changing of radiator fan belt if required and re-fixing the radiator assy on its existing position and testing complete for its satisfactory performance with entire satisfaction of Engineer-in-Charge:- 207 M&L for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm buried directly in ground level with top edge of earth plate at a depth not less than 1.5m below ground level connected to and including galvanized iron strip 25mm x 4mm as earthing lead by means of bolts, nuts, check nuts and washers etc made of GI and connected to earthing test point all as shown in electric plate No. 3 of SSR indicated and testing on completion including excavation and earth work in any type of soil/rock, PCC (1:3:6) type C-1 earthing chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire babric (APM) weight not less than 4 Kg/ Sqm, funnel with GI watering pipe of 20mm bore medium grade, wire mesh and lugs, GI protection pipe of 40mm bore medium grade 7.5 m long test point etc complete all as specified and as directed by Engr-in-Charge. 208 Providing and fixing 25mm x 5mm G.I strip in 40 mm Dia G.I pipe from earth electrode including connection with G.I Nut, bolt, Spring, Waher excavation and refilling etc. as required. 209 Supply & Fix in replacement MCB SP 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 210 Supply & Fix in replacement MCB SPN 6 - 32 Amp, C-curve, 415 volt AC complete all as specified. 211 Supply & Fix in replacement MCB TPN, 40 -63 Amp, C-curve, 415 volt AC complete all as specified. 212 Supply & Fix in replacement AMF controller, three phases, 50 Hz, AC, auto/manual/test/off mode with necessary display complete all as specified. 213 Material & Labour for dismantling the alternator of DG Set of capacity 20 KVA to 75KVA from its base by using chain and pulley after removing the coupling with the engine, removing all nut, bolt with washer and all electrical connection of the alternator, shifting the alternator to workshop by crane and vehicle, opening into parts, checking all winding like main stator/rotor winding, exciter stator/rotor winding. Rewinding the main rotor and exciter rotor by using the “F” class insulation and existing gauge and type of magnet wire which was on original motor, varnishing, heating, drying, greasing the bearing including replacement unserviceable bearing ,re-fixing the complete including connection to the terminal box of the alternator at workshop and shifting the same to the site, fixing the alternator to its base carefully by using chain and pulley, connecting it with existing engine including checking the alignment of alternator with engine connecting all electrical connection of the alternator and testing the DG set “OFF/ FULL LOAD” , matching to the existing range of RPM of the engine output voltage for 415 volt and testing complete all as per the direction of Engineer In Charge. 214 Material & Labour for taking down unserviceable heat insulation from exhaust piping and providing new heat insulation to exhaust pipe using 50 mm thick mineral wool inside the container & up to the exhaust stack. The insulation shall be cladded/ covered with 24G aluminium sheet. Pipe length shall be maximum up to12 Meter long from engineincluding necessary welding works, cladding works with wire mesh and aluminium foil, replace unserviceable supporting MC,angle iron 50 mm X 50 mm X 6 mm, suitable size flange, nut, bolt and washers as required includingweather cowl complete all as specified. 215 Material & Labour for dismantling carefully fuel injection pump (FIP) up to 6 cylinders engine of DG set and transporting to workshop, opening into parts, for maintenance, servicing, overhauling, tuning and calibration, adjustment of nozzle pressure and other controls, replacement of unserviceable spares, re-assembling, re-fixing the FIP on its original position including to and from conveyance charge from site to workshop and back complete all as specified. 216 Material & Labour for dismantling exhaust manifold from the engine to detect the smoke leak, clean the manifold including welding works, replacement of unserviceable spares, packing, bellows, nut, bolt, washers, insulators, etc. reassembling and re-fixing on its base, testing by running the DG set No LOAD/FULL LOAD complete all as specified. 217 S&F in repair 1.5 Sqmm three core PVC insulated, unsheathed multi stranded copper conductor flexible cable 1100 volts grade complete all as specified and directed by Engr in Charge. 218 M&L for preparation of old paintedsurfaces of the DG set and fuel tankof following capacity by cleaning oily and greasy spots using CTC and material and labour for one coat of synthetic enamel paint using spray machine to the fuel tank and one coat of heat resistance paint to Engine / alternator complete all as specified and directed. 219 Note: - Colour code to be followed as under:-(i) Engine body - OG.(ii) Alternator - Siemens grey(iii) Fly wheel guard - Red(iv)Radiator -Black(iv)DG set canopy/complete body with two coats of superior qualitysynthetic enamel paint using spray gun (Area of painting not exceeding 3 sqm) including writingof incoming/outgoing feeder with letters, MES/SM Nos etc completeall as specified. For DG Set capacity 15 KVA to 35 KVA 220 M&L for disconnection of Diesel Oil tank with inlet and outlet diesel pipe line hose/pipe and cleaning of complete oil tank and drain out slug, muddy oil particle complete and re-fixing after at the same place and connecting complete with existing system including marking of tank showing the capacity in Ltrs and replacement of transparent PVC pipe complete all as directed by Engineer-in-Charge:-For DG Set capacity15KVA to 35KVA 221 Supply, install, testing & commissioning in repairs controller- Procom DGC-6D Auto Mains failure control Module including Display, replacing contactors/Connectors and making all electrical connections good and renewed for up to DG set 35 KVA as per existing make complete all as specified and directed by Engr-in-charge. 222 M & L for Servicing of split type Air-conditioning unit comprising Indoor and Outdoor unit of any make/type having capacity 1.0/1.5/2 TR including attending breakdown including required tools and plants,minor electrical sparer like small piece of wire, insulation tape , screws required to rectify the complaints by replacing the spare partsin technical andresidentialbuildingat 14 ASC Kakkanad. Note: Spares required is measured and paid as respective items in Schedule A and all specified and directed by the Engineer - In - Charge. 223 Supply and charge refrigerant gas R-32/R-410 at site including testing all as specified and as directed by Engineer in charge . 224 Supply only Capacitor 36/40 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 225 Supply only Capacitor 50/60 MFD suitable for 230 V 50 HZ AC supply all as specified and as directed by Engineer in charge. Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 226 Supply only Capacitor 80/100MFD suitable for 230 V 50 HZ AC supplyall as specified and as directed by Engineer in charge . Make: USHA / ASIAN / TESLA / EPCOS/ L & T/Keltron) 227 Taking out existing burnt fan motor single phase 230 Voltfrom the unit at site by carefully dismantling the same, taking out burnt copper winding and rewinding the same with super enameled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make including varnishing to copper winding re-assembling the motor and testing the motor at medium and full load complete for the followingall as specified and as directed by Engineer - in - Charge. 228 Splittype AC capacity up to 1.5 Ton 229 Split type AC 2.0 Ton Capacity 230 Taking out old unserviceable PCB and replace the same with new PCB at site suitable for window/split type AC of capacity 1/1.5/2 TR all as specified and directed by Engg-in-charge 231 Taking out carefully existing defective sealed unit compressorSupply & fixing factory made rotary type sealed compressor unit same as per existing model and make including charging the gas and testing & commissioning under normal condition of following rating complete all as specified and directed by Engineer - in - Charge. 232 (a) Split type Ac 1.5/2.0 Ton capacity 233 Removing the damaged insulation of suction and discharge line & Supplying and fixing new Thermal sleeve insulation for suction line and discharge line including providing hard plastic tape over the thermal insulation of split type A/C 1.5 / 2.0 Ton capacity etc complete all as directed by Engineer - in - Charge. 234 M&L in replacement of old unserviceable remote by providing new remote suitable for window type/ split type AC of any capacity/any make as specified and directed by Engineer in Charge. 235 Supply only new capacitor of Fan motor of 4 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 236 Supply only new capacitor of Fan motor of 10 MFD complete all as directed by Engineer - in - Charge. Make: USHA / ASIAN / TESLA / KELTRON / KEIL/ EPCOS. 237 Suply only split type AC indoor unit oscillation motorcomplete all as directed by Engineer - in - Charge. 238 Supply only thermostat for split type AC 1.0/1.5/2.0 complete all as directed by Engineer - in - Charge. Make: INDFOSS / RANTROL / ANNAPURNA. 239 Supply & fix in replacement of factory made MS bracket or Stand duly painted suitable for outdoor unit of split AC including making good disturbed surfaces etc. , all as specified andas directed. 240 M & L Removing the split A/c unit from existing position, of capacity 1.5/2.0 Ton of any make and refix the same in other location by fixing the indoor and outdoor unit in position on fixing on wall/ floor as directed including piping refix the insulation, Gas charging filling the cavities on wall setting of grills alignment complete including, testing & commissioning to the entire satisfaction of Engineer - in - Charge. 241 Supply and fixreplacement 240V 20 Amp singlepole and earth enclosure with a two pin and earth plug and socket complete with one single poleMCB20 Amp SPAll as directedEIC .Make: Legrand , Cat No: 6078 41/Equivalent in L & T/Indo Asian. 242 Taking down the old sub main wiring and M/L for new sub main wiring with 2 run single core 4.0 sq mmPVC unsheathed copper multi stranded, FRLS conductor drawing into and including PVC conduit medium grade of size not less than 20 mm dia with all fittings and fixtures like L- bow, saddles etc of white/lvorycolour PVC conduit including multi stranded copper earth conductor 4.0 sq mm one run as earth continuity conductor all as directed by Engineer in Charge. 243 Supply and fixing in replacement of LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Make: Havells Cat Part No ENDURAPEARLNEOSL45LED757PASYTOPC or its equivalent make of Crompton/Bajaj/HPL/GM. 244 Supply, fixing, connecting and testing in replacement of 150 Watt LED flood light 230 Volt AC outdoor type with thermal management in multiple optics and equipped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Havells Cat No JETAIRISFLS150WLED757PSYMLTG or its equivalent make of Crompton/GM/HPL. 245 Supply and fixing in replacement to ground with suitable pole mounting with OD of 76 mm, connecting and testing 40 Watt LED Post Top Luminaire, 230 Volt AC outdoor type with decorative post top for 360° indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. Make: Crompton Cat Part No LPTO-40-CDL/M or its equivalent make of Havells/Bajaj/GM/HPL. 246 Supply and fixing passing through pole cable 3 core PVC insulated unsheathed multi stranded copper conductor of size 2.5 Sqmm from junction box to lightfitting all as directed by EIC. Make: Havells/Finolex/Poly cab. 247 Supply & fixing in replacement of transparent cover type street light junction box of size 168 mm x 253 mm x 115 mm made of high quality thermoplastic type with hinged and 4 Nos DIN mounted terminal suitable for 10 Sqmm XLPE cable, IP-66 (Dust and power jet Proof according to IEC 60529) , shock proof, rust free, corrosion free acid and chemical resistant, fire retardant having high impact (IK 08) totally insulated (Class II ) made of halogen and silica free recyclable material, UV resistant having high grade gasket made of poly-urethane with copper bus bar 25 x 5 mm -04 strip, one noMCB SP 6 Amps with locking arrangement and 2 Nos M40 size cable gland and one M32 size gland suitable up to, 10Sqmm cable etc and fixing to the street light pole with 02 Nos, 25 x 3 mm thick MS clamps, nuts & bolt, etc. complete all as specified and directed. Make: Hensel Cat Part No KG 9002 or its equivalent make. 248 M & L for removal of existing treatment from PCC poles and applying two coats of weather proof exterior emulsion paint on old painted surface over a coat of primer, complete all as specified and directed by Engineer-in-Charge. 249 M&L for cleaning of feeder pillar/ panel after dismantling the Incoming and outgoing connections from MCBs and replacing the old unserviceable Gland, lugs, nuts & bolts, push buttons, indicating lamps, supporting insulators etc., and checking the serviceability of MCBs, cables and earth continuity conductor including replacement of worn out and unserviceable minor accessories all as specified and directed by Engineer-in-Charge.Note: Spares / materials charge for repair/replacement of worn-out parts shall be measured and paid separately under relevant items. 250 S & F in replacement of MCCB 4 Pole 100-125 Amps 415V 16 KA 251 S & F in replacement of MCB TPN63Amp, 4 Pole, C Curve 252 S & F in replacement of MCB DP 32-40Amp, C Curve 253 S & F in replacement of MCB SP 6 to 32Amp, C Curve 254 Comprehensive Maintenance, Servicing and carrying out periodical service to Voltage Stabilizer, servo type of capacity 63 KVA, 3 phase, 50 c/s, AC including along withrepairing/ replacing of all defective parts such as nut-bolts, washers and all other minor accessories as required at siteall as specified and directed by Engr in charge. Notes: 255 (a) Any additional parts required to be replaced will be measured and paid separately as Supply only against appropriate item of schedule. However labour element and painting involved in replacement are included in quoted rate against this item. 256 (b) Any minor repairs involved to make the voltage stabilizer functional if notified by the Engr-in-Charge shall be carried out by the contractor without any extra cost to the department. (c) Following parts (if renewed) shall be measured and paid separately under appropriate items at Supply only rates and unserviceable parts retrieved through replacement shall be measured under Sch of credit. 257 Disconnecting the complete unit of Servo Controlled voltage stabilizer of capacity 63 KVA, 3 phase, 50 c/s, AC supply of Make- Volteck or as per existing make and overhauling of the same by cleaning, servicing all serviceable accessories including painting with two coats of synthetic enameled paint externally after rubbing of old loose paint along with writing SM No. and capacity on the face of stabilizer and making all connections at both ends including providing lugs on existing cable and testing on full load after completion of repair / overhauling work complete all as specified and directed.NOTE: - (i) Supply only spare parts shall be measured and paid separately under relevant items of this schedule. (ii)Transportation charge / labour charge during the repair of voltage stabilizer from the site to workshop are included in the items of this schedule 258 Supply only following spare parts of 63KVA capacity Servo Voltage Stabilizer complete all as specified and directed: - 259 AC synchronous motor single phase, 50 Hz, 240 volts Make:UNI STEP or equivalent make suitable for volteck servo . 260 Variable auto transformer (Variac). 261 Sensing Transformer. 262 Carbon brush with holder complete. 263 Solid state sensing circuit. 264 RC Net work. 265 PCB connector. 266 Gear big. 267 Carbon fingers. 268 Variac Control CT. 269 Main Bushing with brass rod (insulator & rod). 270 High low cut off relay. 271 Series transformer. 272 Wiring Set. 273 Gear small. 274 Transformers oil filtering with test 275 Replacement of electronic control board 276 Fixing of top cover after repair and testing up to entire satisfaction of Engr in Charge. 277 Supply, installation, testing and commissioning of street light timer control panel, on pole/wall/floor mounting made out of CRCA steel sheet duly powder coated with locking arrangement, including internal wiring complete with bypass arrangements as per manufactures recommendation and design complete all as specified and as directed.Make: Havells Cat Part No IHXTS09120 or its equivalent make of above specification. 278 S&F bracket for fixing to street light poles, made out of suitable dia for fitting of LED street light fittingsmedium grade GI pipe bend to shape inclusive of one primer coat, one under aluminium coat and one aluminium finishing coat of paintall as directed by the Engineer-in- Charge. Make: TATA / Jindal / Surya Praksh. 279 Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.15 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS , CPRI Approved with front opening suitable locking arrangement having copper bus bar of 300 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 in foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following etc complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate. 280 Incoming:(a) MCCB 200 Amp 4 pole 36 KA Ics=100% of Icu with spreader & rom -01 No. (b) Indication Lamp Red/Yellow - 03 No (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No (g) Provision for installation of KESB 3 Phase meter with necessary accessories. 281 Outgoings.(a) 125 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (b) 100 Amp 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No (c) 63 A 4P MCCB 25 KA Ics=100% of Ics with spreader & rom -01 No.(d) 32 Amp 4 MCCB 16 KA, Ics=100% of Ics with spreader & rom -01 No. 282 M & L for re-filling of chemicals (minimum 25-30 ltrof Bentonite chemical / Graphite compound for each earth pit) in existing chemical earthing at technical area for achieving satisfactory earthing value with comprising of the Bentonitecomponents including necessary excavation/drilling for lift of cylindrical copper tubes from the ground and re-fixing the same by using Rig machine and providingenclosure with heavy duty plastic cover having locking arrangement including changing of electrode with pure copper chemical earthing electrode (length ofRod : 3 mtr Approx) for excellent conductivity & work efficiencycomplete all as specified and as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 9
45.
Power #10783122 Price Bid
Tender For Under the deposit scheme year 2025-26, under the Electricity Distribution Division-Mirzapur, under the Government and Private Deposit Scheme, construction of 11 KV line, LT line and line shifting work including installation of transformers of different work - 1 Supply of following Decentralized materials Provide by Contractor at the works site as per RESSPO norms. 2 X-arms holding clamps with bolts & nuts for ST/PCC Pole 3 M.S clamp for Top, T-off channel with bolts & nuts 4 Stone pad 300x300x75 mm 5 F-bracket with bolts & nuts for ST/PCC Pole 6 Danger board with clamp & bolts for ST/PCC Pole 7 Guarding Angle 8 E-bracket with bolts & nuts 9 P.G clamps 10 LT Clamp 11 Z-Clamp 12 Suspension Clamp 13 NEUTRAL CUM EARTH WIRE 14 EYE HOOK 15 Dead end clamp for Suspension 16 Dead end clamp 17 Alluminium Lug of Different size 18 LT Shackle Insulator 19 NUT AND BOLT for Shackle Insulator 20 COPPER L-PIECE 50*225*10 MM SQ 21 COPPER L-PIECE 62*225*12 MM SQ 22 SINGLE PHASE METER BOX 23 SINGLE PHASE METER BOX CLAMP 24 3 PHASE DRISTIBUTION BOX 25 3 PHASE DRISTIBUTION BOX CLAMP 26 BARBED WIRE 27 LOOP GARD 28 JOINTING KIT OUTDOOR/INDOOR 29 ALUMINIUM BINDING WIRE 30 T/F CLAMP 31 Cartage of following materials from ESC, Mirzapur to work site including loading & unloading charge. 32 STP Poles,11 meter long 33 PCC Poles,11 meter long 34 PCC Poles,8.5 meter long 35 Line materials with ACSR Weasel Conductor etc 36 Transformer10 KVA 37 Transformer25 KVA 38 Transformer63 KVA 39 Transformer100 KVA 40 Transformer250 KVA 41 Transformer400 KVA 42 11 KV XLPE Cable size 3x70/120/185mm2 43 11 KV Pilfer proof metering cubicle 44 LT PVC Cable 3.5x25mmsq 45 LT PVC Cable 3.5x50mmsq 46 LT PVC Cable 3.5x70mmsq 47 11 KV CT/PT Combined unit. 48 Erection 49 Erection of single support ST/PCC Pole for construction of 11 KV Line including digging of pit, fitting of all accessories, back filling of earth & others required work. 50 Grouting of pole with 1:4:8 ratio of cement sand & brick ballast as per RESSPO norms(cement sand & brick ballast wil be supplied by the constractor on his own cost) 51 Grouting of stay sets including digging of pit with 1:4:8 ratio of cement sand & brick ballast as per RESSPO norms, fixing binding and nuzzling of stay wire. (cement sand & brick ballast wil be supplied by the constractor on his own his own cost) 52 Earthing of Poles 53 Erection of Sectional Double Pole Structure of ST/PCC Pole including digging of pit. Fitting of accessories back fitting of earth, earthing, grouting of each pole & all stay sets (coment sand & brick ballst will be supplied by the contractor on this own his own cost) & other required works. 54 Stringing & sagging of 3 phase 11 KV line upto proper sag including laying of ACSR Weasel Conductor, binding with insulators & jumpering. 55 Stringing & sagging of LT line upto proper sag including laying of ACSR Weasel Conductor, binding with insulators & jumpering. 56 Drill/cut stone for erection of pole/stay in hill Area 57 Mounting of 10 KVA Transformer along with HT< Connections per RESSPO norms. 58 Mounting of 25 KVA Transformer along with HT< Connections per RESSPO norms. 59 Mounting of 63 KVA Transformer along with HT< Connections per RESSPO norms. 60 Mounting of 100 KVA Transformer along with HT< Connections per RESSPO norms. 61 Mounting of 250 KVA Transformer along with HT< Connections per RESSPO norms. 62 Mounting of 400 KVA Transformer along with HT< Connections per RESSPO norms. 63 Laying, of 11 KV XLPE cable aiongwith cost of bricks & sand as Per RESSPO norms 64 Grouting of11 KV Line as per RESSPO norms 65 Filling of 11cable jointing kit size 3x70/120/185mm2 11 KV indoor type as per Respo norms. 66 Installation of 11 KV Pilfer proof metering cubicle inside meter room, by fixing nut and bolts after checking allgnment with trench & connecting incomming & outgoing cable in the CT Chamber as per RESPO norms. 67 Installation of CT/PT combind unit as per RESPO norms 68 Connection of LT/PVC service cable for consumers 69 PLINTH OF 250 KVA T/F 70 PLINTH OF 400 KVA T/F 71 FANCING OF 250 KVA T/F 72 FANCING OF 400 KVA T/F 73 WELL TYPE EARTHING 100/250/400 KVA 74 Receive back material Of ACSR weasel/dog conductor etc from work site to store centre mzp 75 Receive back material Of Scrap iron from work site to store centre mzp Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
47.
Law and Justice #10762047 Price Bid
Supply Of Forms And Stationery Items-2 Add Gel Pen 3 Alpin (Steel) (Kangaro) 4 Liquid refill ( Allout/Goodnight) 5 Allout Machine/Goodnight Machine ( Mosquito repellant) 6 Angle Holder ( Eletricity items) Anchor/Havells 7 Arch File cardboard Rexin PVC - Neel/Sndia/CaIlas/MS plus 8 Attendance Register Printed and binded as per designated form of Govt. Of Wset Bengal Large Size 9 Attendance Register Printed and binded as per designated form of Govi. Gf Wset oengai Large Size 10 Ball Pen (Blue) Use & Throw ( Link/Montex) 11 Ball Pen(Black) Use & Throw (Link/Montex) 12 Ball point Pen ( Reynolds) 13 Bamboo Broom 14 Battery AA ( Eveready/Panasonic/Nippo) [per pair] 15 Battery AAA ( Eveready/Panasonic/Nippo) 16 Battery Small ( For remote) ( Eveready/Panasonic/Nippo) 17 Baygon Spray (1Ltr) 18 Baygon Spray (1/2 ltr) 19 Baygon Spray ( 5Ltr) 20 Big Size Garbage Bin (80 Ltrs)- Neelkamal 21 Binder Clip (19mm) 22 Binder Clip (25mm) 23 Binder Clip ( 32mm) 24 Binder Clip (Big Size) 25 Binder C(ip ( Small Size) 26 Back tape ( Prime) 27 Blank Register (White) 1•Qr-(50 sheet) FS 60 GSM Maplitho Paper 28 Blank Register (White) 2-Qr-(50 sheet) FS 60 GSM Maplitho Paper 29 Blank Register ( White) 3-Qr-(50 Sheet) FS 60 GSM Maplitho Paper 30 Blank Register ( White) 4-Qr-(50 Sheet) FS 60 GSM Maplitho Paper 31 Blank Register ( White) 5-Qr-(50 Sheet) FS 60 GSM Maplitho Paper 32 Board Pins 33 Bodkin Big Needle 34 Box File ( As per Sample) 35 Box File 60 mm spine holds up to 350 sheets of paper (Ace/ Galopia/Royal) 36 Box File ( Ring Type) Sndia/Ring Binders 37 Box File (SRS Model) Galoppia/Akshar 38 Brasso ( Medium size) 39 Broom Phool 40 Brown Tape ( Big) 4 cms ( cello) 41 Brown Tape 2 inch ( cello) 42 Brown Tape 3 inch ( cello) 43 Bucket 10 Itr( Cello/RFL) 44 Bucket 15 Itr ( Cello/RFL) 45 Bulb 200 watt ( Philips/HeaveIIs/GE) 46 Button Folder legal size ( Dataking/ Ecotail/raetdio) 47 Calculator Casio 12 Digit 48 Calculator Orpat 12 Digit 49 Calculator Pocket Size ( Casio/Orpat) 50 Calculator 12 Digit CT 555 N ( Casio) 51 Calculator Scientific ( Casio) 52 Calling Bell ( Heavells) 53 Candles Wax Household Candles (13 cm x 9 cm x 7 cm) ( 12 stick pkt ) 54 Carbon- Kores 55 Cello Transperent packing tape 1 x 72 yards- 56 CellovTransperent packing tape 2 x 72 yards 57 Cello Transperent packing tape 3/4 x 72 yards 58 Cello Transperent Tape (Big) 4 cms 59 Cello Trnasperent Tape (Small) 60 Cello transperent Tape 1 inch 61 Cello TrnasperentTape 2 inch 62 CFL 85 Watt ( Phillips/ Havells) 63 CFL Bulb 23 Watt ( Phillips/Havells) 64 Chalk Dustless ( 144 nos in a box) - Apsara/ Doms 65 Checking Pencil (Red) ( Apsara/ Doms/nataraj/ Fabercastle) 66 Checking Pencil ( Blue)( Apsara/ Doms/nataraj/ Fabercastle) 67 Clip Board (Clip) Cardboard Type Fabercastle/ Navneet/Camlin) 68 Clip Board (CIip)PVC type Fabercastle/ Navneet/Camlin) 69 Clips Gem (plastic) pkt- Dreamy gem/ Dolphin 70 Clips Gem (Steel)- Dreamy Gem/Arora 71 Colin ( 500mI) 72 Correction Fluid Pen -Kores/ Camlin 73 Cotton Tape Rolls-13 mm (10 yards x 8 rolls) 74 Cup & Plate ( Cello/Diva/La opala) 75 Cup & Plate ( Cello/Diva/La opala) 76 Cuitain 1 MM Thick PVC 6 Strips AC Curtain for Offices & Shop -7 Feet (Dimension-84 * 54 Inches) ( for window) -Kuber 77 Curtain Cloth type for bunglow Modern Polyester Long Crush 3 Piece Curtain Set - (2 Aqua 1 Cream) - 7ft ( door) 78 Curtain Cloth type for bunglow Modern Polyester Long Crush 3 Piece Curtain Set - (2 Aqua 1 Cream) -7ft ( Window) 79 Curtain transperent PVC Eyelet 30 MM AC Curtain 8 Feet (Transparent) - Kuber 80 Duck back ( raincoat) Shirt pant with hood, Comes with pocket on jacket Zipper at the centre 81 Desk calenders ( 10 x 8) 82 Despatch Diary ( Classmate) 83 Disinfectant (Lizol/ Bengal chemical/Nimyle) 84 Dining set ( la opala) 85 Document Tray Plastic 16 x 12- Kuber 86 Door Mat PVC anti skid for office use (Kuber) 87 Double hole punching machine (Kangaro) 88 Drawing pin for notice board 89 Dust Bin Plastic ( Cello/RFL) 90 Duster cloth 91 Duster white (big) 92 Duster white (small) 93 Duster white (50cm x 40cm) 94 Emulsion Rod ( Bajaj/ Havells) 95 Envelop white (11 x 5) 75 GSM with printed text as per sample 96 Envelop A4 size (with printing )-Light blue paper (A4 size) 97 Envelop big (10 x 11) 98 Envelop Half A4 size 99 Envelop small (10/4) 100 Envelop white (A4 size) 75 GSM with printed text as per sample 101 Envelop green plastic coated (12” x10”) as per sample 102 Envelop plain white (9.5”x4.5”) (100 GSM) As per sample 103 Envelop window white (9.5”x 4.5”)(100GSM) As per sample 104 Envelop A3 size(water proof with printing) light blue paper(16”x12”) 105 Envelop brown 10 x5.6 106 Envelop brown 11 x5 107 Envelop brown 16 x6 108 Envelop brown 9 x 4 109 Envelopes SE-5( with printing) Brown paper ( 9 x 4) 110 Envelopes SE-6 ( with printing) Brown paper ( 11 x 5) 111 Envelopes SE-6A ( Cloth line with printing ) Light Blue papepr ( 11 x 5) 112 Envelopes SE-7A ( Cloth line with printing ) Light Blue papepr ( 16 x 6) 113 Envelopes SE-8A ( Cloth line with printing ) Light Blue papepr ( 16 x 12) 114 Envelopes SE 7 ( With printing ( Brown paper ) 16 x 12 115 Envelopes SE 8 ( With printing ( Brown paper ) 16 x 6” 116 Envelopes white 10 x 4.5 117 Envelopes white 11 x 5 118 Envelopes white 16“ x 6” 119 Envelopes white 9 x 4 120 Envelopes white small 10 x 4.5 121 Envelopes window white 10 x 4.5 122 Eraser (Nataraj/Doms/Faber castle)) 123 Fax Roll ( 30 Mtrs, Long) 124 Fevi Stick ( Glue stick) 08 gms 125 Fevi Stick ( Glue stick) 15 gms 126 Fevicol 20ml Tube- Pidilite/equivalent 127 File Board with cloth band no 31 128 File Cover with printed text (as per sample)- Classic/ Royal 129 File Boards- 36 Guage/3lb 130 File Cover with printed text (as per sample)- Classic/ Royal 131 File Cover stickers-15 stickers per leaf 132 File cover ( With Printing) -18 Gage with Eyelets 133 File cover ( With Printing) -27 Gage with Eyelets 134 Function Leather Hole Punch Tool Eyelet Pliers Button- Kangaro 135 File Flap 136 File Movement Register 137 File Tag ( Big Size) 138 File Tag ( Small Size) 139 Floor Duster ( Dozen) 140 Folder Ordinary 141 Folder File Plane/ Auto clip file 142 Full scap Size ( Branded ) 80 GSM- Copy power 143 Full Index ( 2 Quire) 144 Full scap paper (Copy power) 145 Glossy paper for Photo /Certificate printing (Kodak/ Classmate) 146 Glue Liquid any reputed brand 147 Glue Stick ( 15 Gms) 148 Gamaxine ( Red Ant/Allout) 149 Green Note Sheet 90 GSM 150 Hammer ( 250 gms weight) Taparia 151 Hand Gloves ( Hospitality) 152 Hand wash ( 250gms) ( Dettol/savlon) 153 Hard Broom ( 500 gms) ( Coconut Leaves) 154 Harpic 500 ml 155 High Point Marker Pen ( cello) 156 Highlighter ( Luxor) 157 Hit Spray ( Black) 158 Homocol Liquid Soap 159 Index File ( Kangaroo Clip) 160 Index File Folder ( Kangaro) 161 Ink Stamp Pad ( Big Size) Kangaro 162 Jute Folder for document( Legal/A4 size)- Ecotara/student Monk/jute cottage/Any other reputed brand) 163 Jute Twine ( Sutli) per Kg 164 Leather Brief case ( 16 x 5 x 11 ) Sreeleathers 165 Ledger printed Register with Rexin cover as per specification 166 Letter pad ( Classmate) 167 Machine stapler 10m( Small) kangaro 168 Machine stapler 24/6 big size ( Kangaro) 169 Magic tape- 19 mm x 32.9 mm 170 Markin Cloth 171 Marking Flag 172 Metal Scale ( Natraj/Faber Castel/Doms) 173 Mop 2/2 ( spotzero/ gala) 174 Mug (cello/Milton) 175 Multipurpose Self Adhesive Labels -01 ( 210 x297) mm( 48 Labels (Per A4 Size Sheet) Multi Purpose Self Adhesive Labels)- Novajet 176 Multipurpose Self Adhesive Labels -48L ( 48 x24)mm ( 48 Labels (Per A4 Size Sheet) Multi Purpose Self Adhesive Labels)- Novajet 177 Marker for CD (cello/Camlin) 178 Napthaline Balls 179 Napkin Paper 180 Napkin Paper ( Moisture) 181 Note Book 140 Pages ( classmate) 182 Note Books ( Sundaram 200 pages) 183 Note Pad Spiral 184 Note Sheet pad ( Neeraj) 185 Odonil Big size 186 Page marker ( Sticky Flag) 187 Paper Clip ( Vikram Make) 188 Paper T Pins ( Perfect Point make) 189 Paper Cutter 190 Paper fastener Different Sizes) 191 Paper Knife ( Dhyan/ DSR/ Kabeer) 192 Paper pencil carbon ( FS)- Kores 193 Paper Weight Glass 194 Percel Cloth ( cotton) 195 Pen & Pencil Tray ( Omega/Ofixo) 196 Pen ( Permanent Marker) cello 197 Pen Satnd ( Two Pen Holder) 198 Pencil ( Lead) HB ( Nataraj/Doms/ Fabercastle/Apsara) 199 Peon Book as per specification 200 Phinyle Branded (S Ltr) ( Bengal chemical/ Nimyle) 201 PaJstic Binding Rope 202 Pokers ( Big) 203 Pokers ( Small) 204 Punch Double ( Kangaro) 205 Punch Single ( Kangaro) 206 Register 01 Quire ( Classmate) 207 Register 02 Quire ( Classmate) 208 Register 03 Quire ( Classmate) 209 Register 04 Quire ( Classmate) 210 Register 08 Quire ( Classmate) 211 Register 10 Quire ( Classmate) 212 Register 12 Quire ( Classmate) 213 Register Ruled 144 pages Size 8 x13 214 Register Ruled 192 pages Size 8 x13 215 Register Ruled 96 pages Size 8” x13 216 Register ( Naina Deluxe Long Ex- Book 140 pages) 217 Room Heater ( Havelss/ Usha/Venus) 218 Room Spray ( Godrej/Ambipure) 219 Rubber Bands Large- Nylon 220 Rubber Bands Medium- Nylon 221 Rubber Bands Small- Nylon 222 Safety Match Box 223 Scales ( Big Size) 12 Plastic/30 cms- Faber castle/Doms 224 Scales ( Big Size) 12 Stainless steel/30 cms 225 Scissors ( Big)- Scotch/ Map/Dr Morepen 226 Scissors ( Small)- Scotch/map/ Dr Morepen 227 Scotch Brite 228 Screw Driver Set ( Taparia) 229 Sealing Wax 230 Sevice Book as per specification 231 Sharpener ( Natraj/Doms/Faber Castle) 232 Sketch Pen ( Luxor) 233 Sketch Pen Set ( All Colours) ( Luxor) 234 Slide range- Taparia 235 Small Garbage bin ( 20 Itrs)- Neelkamal 236 Soap case ( Any Brand) 237 Sodium Bulb 150 Watt 238 Sodium Bulb 150 Watt Holder 239 Soft Broom for Bunglow 240 Spoon 241 Spray Bottle Blank 242 Stamp Pad ( 11cm X 7cm) Kangaro 243 Stamp Pad ( 15.7cm X 9.6cm) kangaro 244 Stamp Pad ( 15.7cm X 9.6cm) Kangaro 245 Stamp Pad Blue (Kores/Kangaro 246 Stamp Pad Ink 500mI blue/blqck - Camlin 247 Stamp Pad Ink Blue 100mI (Camlin) 248 Stapler Kangaroo HD 10 249 Stapler no. 23 x 17 (Kangaroo) 250 Stapler no. 24 x 6 (Kangaroo) 251 Stapler pin max H-10 ( kangaro) 252 Stapler HD 45 (kangaro) 253 Stapler Machine (big size)- kangaro 254 Stapler Machine (small size)- kangaro 255 Stapler Pin (big)- kangaro 256 Stapler Pin (small)- kangaro 257 Stapler Pin no 10 (Kangaroo) 258 Stapler Pin no 23 x 17 (Kangaroo) 259 Stapler Pin no 24 x 6 (Kangaroo) 260 Sticker (Pre printed) adhesive 261 Surf (1 kg) 262 Surf Excel (1kg) 263 Switch 15A ( havells /Anchor) 264 Switch 5A ( Havells/Anchor) 265 Thermo flucks 1000mI ( cello/ Milton) 266 Thermo flucks 500mI ( cello/ Milton) 267 Thread Ball 268 Thread Bundle (Big) 269 Three Pin Top 15A 270 Three Pin Top 5A 271 Tissue paper for toilet (quality) 272 Toilet Acid 5 ltr 273 Toilet Brush ( cello/Milton) 274 Torch 2 cell ( Eveready) 275 Torch 3 cell ( Evaready) 276 Torch cell ( Evaready) 277 Towel car size ( Bombay Dying) 278 Towel coloured full size ( Bombay Dying) 279 Towel full size white ( Bombay Dying) 280 Towel small ( Bombay Dying) 281 Tube 40 watt ( Phillips/Havells) 282 Umbrella ( Mehndra Dutta/KC paul) 283 Urinal Cube 284 Vim 1 kg 285 Waste paper busket 286 Water Glass 287 White board duster 288 White board Marker Pens 289 White cloth cotton 290 White duster 291 White Eraze fluid ( camlin) 292 White Full Scape Paper ( A3) 75 GSM- Copy Power 293 Whitener Pen ( camlin) 294 Xerox Copier ( A4 Size) 75 GSM ( Copy Power) 295 Xerox Copier ( B4 Size) 75 GSM - Copy Power 296 Xerox Copier ( FS Size) 75 GSM - Copy power 297 Chair ( Executive) ( Godrej/Neelkamal) 298 Chbir ( Normal) Neelkamal/Supreme) 299 Office Table ( 5’ x 3 ) Godrej 300 Office Table ( 4 x 2.6) godrej 301 Office Table ( 6’ x 3) Godrej 302 Computer Table (Godrej/ Neelkamal) 303 Wall Clock ( Big Size)( Ajanta/Orpat) 304 Wall Clock ( Medium Size) -Ajanta/Orpat 305 Office Almirah ( Godrej) 306 Office Almirah with locker system ( Godrej0 307 Wooden Chair with handle ( Teak Wood) 308 Hand Sanitizer ( Dettol/ savlon/Lifebouy) 309 Flex ( Good Quality) 310 Plastic Chair without Handle(NeeIkamaI/Suprerme) 311 Powder earth Fire Extenguiser( Ceasrfire/ Ecofire)- 2kg 312 Powder earth Fire Extenguiser( Ceasrfire/ Ecofire)- 3kg 313 Powder earth Fire Extenguiser( Ceasrfire/ Ecofire)- 4kg 314 Powder earth Fire Extenguiser( Ceasrfire/ Ecofire)- Skg 315 Powder earth Fire Extenguiser( Ceasrfire/ Ecofire)- 6kg 316 Ceiling Fan ( Crompton Greives/Usha/Orient/Havells) 317 Table Fan ( Crompton Greives/Usha/Orient/Havells) 318 Stand Fan ( Crompton Greives/Usha/Orient/Havells) 319 Wall Fan ( Crompton Greives/Usha/Orient/Havells) 320 Plastic water Bottle (Cello/Milton)-500mI 321 Plastic water Bottle (Cello/Milton)-1000mI 322 Jute bag with inside plastic qouted ( Skg) 323 Jute bag with inside plastic qouted ( 10kg) 324 Jute bag with inside plastic qouted ( 15kg) 325 Leather bag 37cm x27cm x7cm carrying laptop, file etc (Sreeleathers) 326 Office bag 16 x 6 x11 canvas polyster, 2 main compartments with zipper, 2 small compartments with zipper, 1 big compartments with laptop, charger etc( Sreeleathers) 327 Trunk( plain Sheet material) 36 x18 x18 328 Lock Big size 6 lever ( Godrej) 329 Lock Big size 4 lever9 Godrej) 330 Lock medium size 4 lever ( Godrej) 331 Lock small size 4 lever ( Godrej) 332 Wire ( Flexible elctric) 2mm - Havells 333 Flexible elctric wire 4mm 334 Wire ( Flexible elctric) 6mm - Havells 335 8mm thick Glass on Table top ( Non specified) 336 Office table cover ( Non specified) 337 Erathen Pot 18 long 12 dia ( Non specified) 338 Erathen Pot 12 long 8 dia ( Non specified) 339 Erathen Pot 8 long 5 dia ( Non specified) 340 Plastic Pot 18” long 12 dia ( Non specified) 341 Plastic Pot 12 long 8 long ( Non specified) 342 Plastic Pot 8 long 5 dia ( Non specified) 343 OPice Notice Board 4 x 3’ (Roger & Moris Premium Notice Board/Asian) 344 Mosquito Coil ( Mortein) 345 Flower vase ( Non specified) 346 Rubber Stamp 347 Musquito Killing Machine 348 Electric Kettly 349 Binding Register 350 Exercise Book 351 Bahadur Khata 352 Digital Wall Clock 353 Gala Stick 354 T-Pin 355 Toilet Cleaner(Harpic) 356 Carbon Paper Double Side 357 Use & Throw Pen 358 Brown Paper 359 White Paper 360 Colour Tag 361 Gurder 362 Measurement Tape 363 Flash Light 364 Key Holding Rack 365 Name Plate Brass 366 Fevi Gum (400ML) 367 Marker Permanent 368 White Board(3x2)SQFT 369 Pan Brush 370 Dhul Jharu 371 Notice Board 372 Water Bottele(Milton) 373 Bill Register 374 Govt. Cash Book 375 Stell Bowl Big 376 Stell Bowl Small 377 Lock & Key Small 378 Glass Cleaner(Colin) 379 Whitener 380 A3 Paper 381 Legal Paper 382 Camp Kot 383 Plastic Cover File 384 Cover Dust Bin 385 Drinking Water Glass 386 Nylon Bucket 387 Pin Pot 388 Envelope Legal Size 389 Extension Board 390 Gumbot 391 Halogen Light
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
West Bengal View Result →
48.
Law and Justice #10761938 Price Bid
Supply Of Forms And Stationery Items In The Office Of The District Magistrate, Darjeeling For The Financial Year-2022-23 , Supply Of Stattionary Items In The Office Of The District Magistrate Darjeeling For Fy 2021-2022 , Add Gel Pen , Alpin ( Steel ) ( Kangaro ) , Liquid Refill ( Allout / Goodnight ) , Allout Machine / Goodnight Machine ( Mosquito Repellant ) , Angle Holder ( Eletricity Items ) Anchor / Havells , Arch File Cardboard Rexin Pvc - Neel / Sndia / Cailas / Ms Plus , Attendance Register Printed And Binded As Per Designated Form Of Govt. Of Wset Bengal Large Size , Attendance Register Printed And Binded As Per Designated Form Of Govi. Gf Wset Oengai Large Size , Ball Pen ( Blue ) Use & Throw ( Link / Montex ) , Ball Pen ( Black ) Use & Throw ( Link / Montex ) , Ball Point Pen ( Reynolds ) , Bamboo Broom , Battery Aa ( Eveready / Panasonic / Nippo ) [ Per Pair ] , Battery Aaa ( Eveready / Panasonic / Nippo ) , Battery Small ( For Remote ) ( Eveready / Panasonic / Nippo ) , Baygon Spray ( 1Ltr ) , Baygon Spray ( 1 / 2 Ltr ) , Baygon Spray ( 5Ltr ) , Big Size Garbage Bin ( 80 Ltrs ) - Neelkamal , Binder Clip ( 19Mm ) , Binder Clip ( 25Mm ) , Binder Clip ( 32Mm ) , Binder Clip ( Big Size ) , Binder C ( Ip ( Small Size ) , Back Tape ( Prime ) , Blank Register ( White ) 1•Qr- ( 50 Sheet ) Fs 60 Gsm Maplitho Paper , Blank Register ( White ) 2-Qr- ( 50 Sheet ) Fs 60 Gsm Maplitho Paper , Blank Register ( White ) 3-Qr- ( 50 Sheet ) Fs 60 Gsm Maplitho Paper , Blank Register ( White ) 4-Qr- ( 50 Sheet ) Fs 60 Gsm Maplitho Paper , Blank Register ( White ) 5-Qr- ( 50 Sheet ) Fs 60 Gsm Maplitho Paper , Board Pins , Bodkin Big Needle , Box File ( As Per Sample ) , Box File 60 Mm Spine Holds Up To 350 Sheets Of Paper ( Ace / Galopia / Royal ) , Box File ( Ring Type ) Sndia / Ring Binders , Box File ( Srs Model ) Galoppia / Akshar , Brasso ( Medium Size ) , Broom Phool , Brown Tape ( Big ) 4 Cms ( Cello ) , Brown Tape 2 Inch ( Cello ) , Brown Tape 3 Inch ( Cello ) , Bucket 10 Itr ( Cello / Rfl ) , Bucket 15 Itr ( Cello / Rfl ) , Bulb 200 Watt ( Philips / Heaveiis / Ge ) , Button Folder Legal Size ( Dataking / Ecotail / Raetdio ) , Calculator Casio 12 Digit , Calculator Orpat 12 Digit , Calculator Pocket Size ( Casio / Orpat ) , Calculator 12 Digit Ct 555 N ( Casio ) , Calculator Scientific ( Casio ) , Calling Bell ( Heavells ) , Candles Wax Household Candles ( 13 Cm X 9 Cm X 7 Cm ) ( 12 Stick Pkt ) , Carbon- Kores , Cello Transperent Packing Tape 1 X 72 Yards- , Cellovtransperent Packing Tape 2 X 72 Yards , Cello Transperent Packing Tape 3 / 4 X 72 Yards , Cello Transperent Tape ( Big ) 4 Cms , Cello Trnasperent Tape ( Small ) , Cello Transperent Tape 1 Inch , Cello Trnasperenttape 2 Inch , Cfl 85 Watt ( Phillips / Havells ) , Cfl Bulb 23 Watt ( Phillips / Havells ) , Chalk Dustless ( 144 Nos In A Box ) - Apsara / Doms , Checking Pencil ( Red ) ( Apsara / Doms / Nataraj / Fabercastle ) , Checking Pencil ( Blue ) ( Apsara / Doms / Nataraj / Fabercastle ) , Clip Board ( Clip ) Cardboard Type Fabercastle / Navneet / Camlin ) , Clip Board ( Ciip ) Pvc Type Fabercastle / Navneet / Camlin ) , Clips Gem ( Plastic ) Pkt- Dreamy Gem / Dolphin , Clips Gem ( Steel ) - Dreamy Gem / Arora , Colin ( 500Mi ) , Correction Fluid Pen -Kores / Camlin , Cotton Tape Rolls-13 Mm ( 10 Yards X 8 Rolls ) , Cup & Plate ( Cello / Diva / La Opala ) , Cup & Plate ( Cello / Diva / La Opala ) , Cuitain 1 Mm Thick Pvc 6 Strips Ac Curtain For Offices & Shop -7 Feet ( Dimension-84 * 54 Inches ) ( For Window ) -Kuber , Curtain Cloth Type For Bunglow Modern Polyester Long Crush 3 Piece Curtain Set - ( 2 Aqua 1 Cream ) - 7Ft ( Door ) , Curtain Cloth Type For Bunglow Modern Polyester Long Crush 3 Piece Curtain Set - ( 2 Aqua 1 Cream ) -7Ft ( Window ) , Curtain Transperent Pvc Eyelet 30 Mm Ac Curtain 8 Feet ( Transparent ) - Kuber , Duck Back ( Raincoat ) Shirt Pant With Hood, Comes With Pocket On Jacket Zipper At The Centre , Desk Calenders ( 10 X 8 ) , Despatch Diary ( Classmate ) , Disinfectant ( Lizol / Bengal Chemical / Nimyle ) , Dining Set ( La Opala ) , Document Tray Plastic 16 X 12- Kuber , Door Mat Pvc Anti Skid For Office Use ( Kuber ) , Double Hole Punching Machine ( Kangaro ) , Drawing Pin For Notice Board , Dust Bin Plastic ( Cello / Rfl ) , Duster Cloth , Duster White ( Big ) , Duster White ( Small ) , Duster White ( 50Cm X 40Cm ) , Emulsion Rod ( Bajaj / Havells ) , Envelop White ( 11 X 5 ) 75 Gsm With Printed Text As Per Sample , Envelop A4 Size ( With Printing ) -Light Blue Paper ( A4 Size ) , Envelop Big ( 10 X 11 ) , Envelop Half A4 Size , Envelop Small ( 10 / 4 ) , Envelop White ( A4 Size ) 75 Gsm With Printed Text As Per Sample , Envelop Green Plastic Coated ( 12” X10” ) As Per Sample , Envelop Plain White ( 9.5”X4.5” ) ( 100 Gsm ) As Per Sample , Envelop Window White ( 9.5”X 4.5” ) ( 100Gsm ) As Per Sample , Envelop A3 Size ( Water Proof With Printing ) Light Blue Paper ( 16”X12” ) , Envelop Brown 10 X5.6 , Envelop Brown 11 X5 , Envelop Brown 16 X6 , Envelop Brown 9 X 4 , Envelopes Se-5 ( With Printing ) Brown Paper ( 9 X 4 ) , Envelopes Se-6 ( With Printing ) Brown Paper ( 11 X 5 ) , Envelopes Se-6A ( Cloth Line With Printing ) Light Blue Papepr ( 11 X 5 ) , Envelopes Se-7A ( Cloth Line With Printing ) Light Blue Papepr ( 16 X 6 ) , Envelopes Se-8A ( Cloth Line With Printing ) Light Blue Papepr ( 16 X 12 ) , Envelopes Se 7 ( With Printing ( Brown Paper ) 16 X 12 , Envelopes Se 8 ( With Printing ( Brown Paper ) 16 X 6” , Envelopes White 10 X 4.5 , Envelopes White 11 X 5 , Envelopes White 16“ X 6” , Envelopes White 9 X 4 , Envelopes White Small 10 X 4.5 , Envelopes Window White 10 X 4.5 , Eraser ( Nataraj / Doms / Faber Castle ) ) , Fax Roll ( 30 Mtrs, Long ) , Fevi Stick ( Glue Stick ) 08 Gms , Fevi Stick ( Glue Stick ) 15 Gms , Fevicol 20Ml Tube- Pidilite / Equivalent , File Board With Cloth Band No 31 , File Cover With Printed Text ( As Per Sample ) - Classic / Royal , File Boards- 36 Guage / 3Lb , File Cover With Printed Text ( As Per Sample ) - Classic / Royal , File Cover Stickers-15 Stickers Per Leaf , File Cover ( With Printing ) -18 Gage With Eyelets , File Cover ( With Printing ) -27 Gage With Eyelets , Function Leather Hole Punch Tool Eyelet Pliers Button- Kangaro , File Flap , File Movement Register , File Tag ( Big Size ) , File Tag ( Small Size ) , Floor Duster ( Dozen ) , Folder Ordinary , Folder File Plane / Auto Clip File , Full Scap Size ( Branded ) 80 Gsm- Copy Power , Full Index ( 2 Quire ) , Full Scap Paper ( Copy Power ) , Glossy Paper For Photo / Certificate Printing ( Kodak / Classmate ) , Glue Liquid Any Reputed Brand , Glue Stick ( 15 Gms ) , Gamaxine ( Red Ant / Allout ) , Green Note Sheet 90 Gsm , Hammer ( 250 Gms Weight ) Taparia , Hand Gloves ( Hospitality ) , Hand Wash ( 250Gms ) ( Dettol / Savlon ) , Hard Broom ( 500 Gms ) ( Coconut Leaves ) , Harpic 500 Ml , High Point Marker Pen ( Cello ) , Highlighter ( Luxor ) , Hit Spray ( Black ) , Homocol Liquid Soap , Index File ( Kangaroo Clip ) , Index File Folder ( Kangaro ) , Ink Stamp Pad ( Big Size ) Kangaro , Jute Folder For Document ( Legal / A4 Size ) - Ecotara / Student Monk / Jute Cottage / Any Other Reputed Brand ) , Jute Twine ( Sutli ) Per Kg , Leather Brief Case ( 16 X 5 X 11 ) Sreeleathers , Ledger Printed Register With Rexin Cover As Per Specification , Letter Pad ( Classmate ) , Machine Stapler 10M ( Small ) Kangaro , Machine Stapler 24 / 6 Big Size ( Kangaro ) , Magic Tape- 19 Mm X 32.9 Mm , Markin Cloth , Marking Flag , Metal Scale ( Natraj / Faber Castel / Doms ) , Mop 2 / 2 ( Spotzero / Gala ) , Mug ( Cello / Milton ) , Multipurpose Self Adhesive Labels -01 ( 210 X297 ) Mm ( 48 Labels ( Per A4 Size Sheet ) Multi Purpose Self Adhesive Labels ) - Novajet , Multipurpose Self Adhesive Labels -48L ( 48 X24 ) Mm ( 48 Labels ( Per A4 Size Sheet ) Multi Purpose Self Adhesive Labels ) - Novajet , Marker For Cd ( Cello / Camlin ) , Napthaline Balls , Napkin Paper , Napkin Paper ( Moisture ) , Note Book 140 Pages ( Classmate ) , Note Books ( Sundaram 200 Pages ) , Note Pad Spiral , Note Sheet Pad ( Neeraj ) , Odonil Big Size , Page Marker ( Sticky Flag ) , Paper Clip ( Vikram Make ) , Paper T Pins ( Perfect Point Make ) , Paper Cutter , Paper Fastener Different Sizes ) , Paper Knife ( Dhyan / Dsr / Kabeer ) , Paper Pencil Carbon ( Fs ) - Kores , Paper Weight Glass , Percel Cloth ( Cotton ) , Pen & Pencil Tray ( Omega / Ofixo ) , Pen ( Permanent Marker ) Cello , Pen Satnd ( Two Pen Holder ) , Pencil ( Lead ) Hb ( Nataraj / Doms / Fabercastle / Apsara ) , Peon Book As Per Specification , Phinyle Branded ( S Ltr ) ( Bengal Chemical / Nimyle ) , Pajstic Binding Rope , Pokers ( Big ) , Pokers ( Small ) , Punch Double ( Kangaro ) , Punch Single ( Kangaro ) , Register 01 Quire ( Classmate ) , Register 02 Quire ( Classmate ) , Register 03 Quire ( Classmate ) , Register 04 Quire ( Classmate ) , Register 08 Quire ( Classmate ) , Register 10 Quire ( Classmate ) , Register 12 Quire ( Classmate ) , Register Ruled 144 Pages Size 8 X13 , Register Ruled 192 Pages Size 8 X13 , Register Ruled 96 Pages Size 8” X13 , Register ( Naina Deluxe Long Ex- Book 140 Pages ) , Room Heater ( Havelss / Usha / Venus ) , Room Spray ( Godrej / Ambipure ) , Rubber Bands Large- Nylon , Rubber Bands Medium- Nylon , Rubber Bands Small- Nylon , Safety Match Box , Scales ( Big Size ) 12 Plastic / 30 Cms- Faber Castle / Doms , Scales ( Big Size ) 12 Stainless Steel / 30 Cms , Scissors ( Big ) - Scotch / Map / Dr Morepen , Scissors ( Small ) - Scotch / Map / Dr Morepen , Scotch Brite , Screw Driver Set ( Taparia ) , Sealing Wax , Sevice Book As Per Specification , Sharpener ( Natraj / Doms / Faber Castle ) , Sketch Pen ( Luxor ) , Sketch Pen Set ( All Colours ) ( Luxor ) , Slide Range- Taparia , Small Garbage Bin ( 20 Itrs ) - Neelkamal , Soap Case ( Any Brand ) , Sodium Bulb 150 Watt , Sodium Bulb 150 Watt Holder , Soft Broom For Bunglow , Spoon , Spray Bottle Blank , Stamp Pad ( 11Cm X 7Cm ) Kangaro , Stamp Pad ( 15.7Cm X 9.6Cm ) Kangaro , Stamp Pad ( 15.7Cm X 9.6Cm ) Kangaro , Stamp Pad Blue ( Kores / Kangaro , Stamp Pad Ink 500Mi Blue / Blqck - Camlin , Stamp Pad Ink Blue 100Mi ( Camlin ) , Stapler Kangaroo Hd 10 , Stapler No. 23 X 17 ( Kangaroo ) , Stapler No. 24 X 6 ( Kangaroo ) , Stapler Pin Max H-10 ( Kangaro ) , Stapler Hd 45 ( Kangaro ) , Stapler Machine ( Big Size ) - Kangaro , Stapler Machine ( Small Size ) - Kangaro , Stapler Pin ( Big ) - Kangaro , Stapler Pin ( Small ) - Kangaro , Stapler Pin No 10 ( Kangaroo ) , Stapler Pin No 23 X 17 ( Kangaroo ) , Stapler Pin No 24 X 6 ( Kangaroo ) , Sticker ( Pre Printed ) Adhesive , Surf ( 1 Kg ) , Surf Excel ( 1Kg ) , Switch 15A ( Havells / Anchor ) , Switch 5A ( Havells / Anchor ) , Thermo Flucks 1000Mi ( Cello / Milton ) , Thermo Flucks 500Mi ( Cello / Milton ) , Thread Ball , Thread Bundle ( Big ) , Three Pin Top 15A , Three Pin Top 5A , Tissue Paper For Toilet ( Quality ) , Toilet Acid 5 Ltr , Toilet Brush ( Cello / Milton ) , Torch 2 Cell ( Eveready ) , Torch 3 Cell ( Evaready ) , Torch Cell ( Evaready ) , Towel Car Size ( Bombay Dying ) , Towel Coloured Full Size ( Bombay Dying ) , Towel Full Size White ( Bombay Dying ) , Towel Small ( Bombay Dying ) , Tube 40 Watt ( Phillips / Havells ) , Umbrella ( Mehndra Dutta / Kc Paul ) , Urinal Cube , Vim 1 Kg , Waste Paper Busket , Water Glass , White Board Duster , White Board Marker Pens , White Cloth Cotton , White Duster , White Eraze Fluid ( Camlin ) , White Full Scape Paper ( A3 ) 75 Gsm- Copy Power , Whitener Pen ( Camlin ) , Xerox Copier ( A4 Size ) 75 Gsm ( Copy Power ) , Xerox Copier ( B4 Size ) 75 Gsm - Copy Power , Xerox Copier ( Fs Size ) 75 Gsm - Copy Power , Chair ( Executive ) ( Godrej / Neelkamal ) , Chbir ( Normal ) Neelkamal / Supreme ) , Office Table ( 5’ X 3 ) Godrej , Office Table ( 4 X 2.6 ) Godrej , Office Table ( 6’ X 3 ) Godrej , Computer Table ( Godrej / Neelkamal ) , Wall Clock ( Big Size ) ( Ajanta / Orpat ) , Wall Clock ( Medium Size ) -Ajanta / Orpat , Office Almirah ( Godrej ) , Office Almirah With Locker System ( Godrej0 , Wooden Chair With Handle ( Teak Wood ) , Hand Sanitizer ( Dettol / Savlon / Lifebouy ) , Flex ( Good Quality ) , Plastic Chair Without Handle ( Neeikamai / Suprerme ) , Powder Earth Fire Extenguiser ( Ceasrfire / Ecofire ) - 2Kg , Powder Earth Fire Extenguiser ( Ceasrfire / Ecofire ) - 3Kg , Powder Earth Fire Extenguiser ( Ceasrfire / Ecofire ) - 4Kg , Powder Earth Fire Extenguiser ( Ceasrfire / Ecofire ) - Skg , Powder Earth Fire Extenguiser ( Ceasrfire / Ecofire ) - 6Kg , Ceiling Fan ( Crompton Greives / Usha / Orient / Havells ) , Table Fan ( Crompton Greives / Usha / Orient / Havells ) , Stand Fan ( Crompton Greives / Usha / Orient / Havells ) , Wall Fan ( Crompton Greives / Usha / Orient / Havells ) , Plastic Water Bottle ( Cello / Milton ) -500Mi , Plastic Water Bottle ( Cello / Milton ) -1000Mi , Jute Bag With Inside Plastic Qouted ( Skg ) , Jute Bag With Inside Plastic Qouted ( 10Kg ) , Jute Bag With Inside Plastic Qouted ( 15Kg ) , Leather Bag 37Cm X27cm X7cm Carrying Laptop, File Etc ( Sreeleathers ) , Office Bag 16 X 6 X11 Canvas Polyster, 2 Main Compartments With Zipper, 2 Small Compartments With Zipper, 1 Big Compartments With Laptop, Charger Etc ( Sreeleathers ) , Trunk ( Plain Sheet Material ) 36 X18 X18 , Lock Big Size 6 Lever ( Godrej ) , Lock Big Size 4 Lever9 Godrej ) , Lock Medium Size 4 Lever ( Godrej ) , Lock Small Size 4 Lever ( Godrej ) , Wire ( Flexible Elctric ) 2Mm - Havells , Flexible Elctric Wire 4Mm , Wire ( Flexible Elctric ) 6Mm - Havells , 8Mm Thick Glass On Table Top ( Non Specified ) , Office Table Cover ( Non Specified ) , Erathen Pot 18 Long 12 Dia ( Non Specified ) , Erathen Pot 12 Long 8 Dia ( Non Specified ) , Erathen Pot 8 Long 5 Dia ( Non Specified ) , Plastic Pot 18” Long 12 Dia ( Non Specified ) , Plastic Pot 12 Long 8 Long ( Non Specified ) , Plastic Pot 8 Long 5 Dia ( Non Specified ) , Opice Notice Board 4 X 3’ ( Roger & Moris Premium Notice Board / Asian ) , Mosquito Coil ( Mortein ) , Flower Vase ( Non Specified ) , Rubber Stamp , Musquito Killing Machine , Electric Kettly , Binding Register , Exercise Book , Bahadur Khata , Digital Wall Clock , Gala Stick , T-Pin , Toilet Cleaner ( Harpic ) , Carbon Paper Double Side , Use & Throw Pen , Brown Paper , White Paper , Colour Tag , Gurder , Measurement Tape , Flash Light , Key Holding Rack , Name Plate Brass , Fevi Gum ( 400Ml ) , Marker Permanent , White Board ( 3X2 ) Sqft , Pan Brush , Dhul Jharu , Notice Board , Water Bottele ( Milton ) , Bill Register , Govt. Cash Book , Stell Bowl Big , Stell Bowl Small , Lock & Key Small , Glass Cleaner ( Colin ) , Whitener , A3 Paper , Legal Paper , Camp Kot , Plastic Cover File , Cover Dust Bin , Drinking Water Glass , Nylon Bucket , Pin Pot , Envelope Legal Size , Extension Board , Hp 12A Tonner Original , Hp 12A Compatible , Hp 88A Tonner Original , Hp 88A Compatible , Hp 78A Tonner Original , Hp 78A Compatible , Hp 78A Tonner Original , Hp 36A Compatible , Halogen Light
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 8
West Bengal View Result →
49.
Shipping #10758365 Price Bid
Tender For Electrical Package 1 For Icgs Samudra Paheredar--1 Electrical Repair Package Jobs 2 Lub Oil Priming Pump Motors Of All Four Main Das To Be Overhauled. ( Material Contractor Supply ) . 3 Shaft Generator ( 2300 Kw, 415V, 3- Phase ) – 02 Nos, M / S Avkdeutschand, 4 Overhaul Both ( Port &Stbd ) Shaft Generator As Follows:- ( A ) Examination Of Power Cables, Cable Entry, Cable Shoes And Ct On Terminal Box. ( B ) Cleaning &Examination Of Insulators For Cracks. ( C ) Check And Re-Tightening Of All Screws And Nuts In Aux. Terminal Box. ( D ) Check And Re-Tightening Of All Screws And Nuts In Aux. Terminal Box By Dynamometric Key. ( E ) Inspection Of Stator And Rotor Winding With Endoscope.On Completion Of Overhauling Laser Alignment Of Shaft Generators To Be Carried Out With Main Shaft Of Prime Mover. ( All In Way Jobs / Materials And Spares Under Contractor Scope ) 5 Emergency Switch Board ( M / S Rrmi ) 6 Circuitbreakers { ( Make-Merlingerlin, 400Amps } Tobeoverhauledand Safety Trip Checks ( Over Current, Short Circuit & Under Voltage ) To Be Carried Out. ( A ) Record The Bus Bar Insulation. Insulation Should Be >5 Mega Ohm. ( B ) Rubber Beading Of The Panel Doors To Be Renewed. ( Mat Contractor Supply ) Calibration Certificate To Be Provided. 7 Following Meters To Be Calibrated And Calibration Certificate To Be Provided. 8 Ammeter ( 0 – 1000 Amp ) 9 Voltmeter ( 0 – 600 V ) 10 Frequency Meter ( 45 – 55 Hz ) 11 Calibrate All Meters In Both Msb. Calibration Certificate To Be Provided. 12 Meter Description Range Msb ( P ) Qtymsb ( S ) Qty 13 Voltmeter ( 0 – 300 V ) 01 01 14 Voltmeter ( 0 – 600 V ) 04 05 15 Insulation Meter 0 - 8M? 03 03 16 Ammeter ( 0 – 5000 A ) 0303 17 Ammeter ( 0 – 3000 A ) 0706 18 Kw Tmeter ( -150 To 500 Kw ) 0304 19 Kw Tmeter ( -2875 To +2875 Kw ) 01 02 20 Frequency Tmeter ( 44 - 55 Hz ) 04 05 21 Synchroscope…. 0304 22 Pf Meter ( -0.5 To 1 To+0.5 ) 03 04 23 Transformers ( 99Kva-02 No, 40Kva- 01No. ) 415 / 230V, 3-Phase, M / S Marine Electrical 24 Overhaulthetransformers ( 99Kva-02Noswindingstobe Applied With Air Drying Varnish. Post Overhauling, Transformers Are To Be Proved For Satisfactory Operation. 25 Overhaulthetransformers ( 40Kva–01No ) , Windingstobe Applied With Air Drying Varnish. Post Overhauling, Transformers Are To Be Proved For Satisfactory Operation. 26 Shore Connection Box ( 415V, 3-Phase, 800A ) - 02 No., M / S Marine Electricals 27 Overhauling Of 02 No Shore Connection Box And 01 No Shore Bus Bar Panel To Be Carried Out. Job Includes Following;A ) Undertake Cit Of Mccb-800Ab ) Renew Insulator Bushings Of Bus Bar. 28 Calibration Of Following Meters To Be Carried Out And Calibration Certificate To Be Provided. 29 Voltmeter ( 0-500V ) 30 Ammeter ( 0-1000A ) 31 Kwh Meter 32 Phase sequence meter 33 INTERRING STABILIZER –02 NO, M/S RRMI (INPUT 230 V,AC) 34 Following tests to be carried out as per manual :-(a) 04 different tests for check of the stabilizer logic.(b) Arbitrary periods of roll (10, 15, 20 and 30 sec) to be checked for pneumatic valve and stabilizer valves.(c) RS Test for check of Roll sensor to be carried out. 35 INCINERATOR, M/S TEAMTEC, QTY-01 NO 36 Incineratornon-operationalviewsuspecteddefectivePLCandsystemnotgetting switched-on. Incinerator tobeoverhauled. Defect to berectified andsystemto be proved with correct operation of following alarms.List of alarms: -(a) Flue gas temp. High.(b) Combustion chamber temp. high & low(c) Diesel oil temp high &low(d) Door not closed(e) Motor overload(f) Low and high voltage(g) Low sludge pressure(h) Sludge tank temp. high(j) Low level sludge tank(k) Diesel oil press. Low 37 ELECTRIC SIREN M/S ZETFONE 38 Overhauling of electric siren motor (415 V AC, 3-Phase, 50 HZ, 5.5 KW) and control panel to be carried out. System to be proved for satisfactory operation. (Mat & Spares contractor supply) 39 AIR WHISTLE – 01 NO. M/S KOCKUM SONIC 40 Overhauling of air whistle and control panel to be carried out. System to be proved for satisfactory operation. (Mat & Spares contractor supply) 41 FI-FI control panel to be overhauled. Overhauling includes calibration of OLR (3RV 1011-1 DA10, 2.2 A to 3.2 A, Qty-02 Nos and functional checks of Fi-Fi system in remote and fixed operator panel. Calibration certificate to be provided. (All items contractor supply). 42 REMOTE OPERATED SOLENOID VALVE & RELAY PANEL (M/S ROTEX) 43 Pneumatic remote operated solenoid valve relay panel to be overhauled. The overhaulincludeschecking relays&solenoidswithpneumaticvalves. CalibrationofOLR(0.4-0.63A,TR2M,)tobecarriedout.Calibration certificate to be provided. 44 Overhauling of control panel 45 Checking of relays&solenoidswithpneumaticvalves 46 CalibrationofOLR(0.4-0.63A,TR2M) 47 Overhauling of following ventilation fan motors alongwith blowers to be carried out as per instruction mentioned in technical requirement. 48 Name of Motor SpecificationLocation 49 Supply Fan S-2A415 V, 11 KWMER (P) 50 Supply Fan S-2B415 V, 11 KWMER (S) 51 Supply Fan S-3A415 V, 30 KWAER (P) 52 Supply Fan S-3B415 V, 30 KWAER (S) 53 Overhauling of following ventilation fan starter panels to be carried out as per instruction mentioned in technical requirement. Calibration of over load Relay to be carried out. Calibration certificate to be provided.(All items contractor supply) 54 Name of MotorSpecificationLocation OLR Details 55 Supply Fan S-2A415 V, 11 KW MER (P) LRD 22 (16-24A) 56 Supply Fan S-2B415 V, 11 KW MER (S) LRD 22 (16-24A) 57 Supply Fan S-3A415 V, 30 KW AER (P) LR2D33 (48-65A) 58 Supply Fan S-3B415 V, 30 KW AER (S) LR2D33 (48-65A) 59 Following exhaust ventilation fans are defective. Same to be renewed as per sample. In way job includes removal & refitment of paneling and trunking. (Spares and material contractor Supply) 60 FM -200 Room (415V 0.37 KW) 61 Galley (415 V 1.0 KW) 62 12 Sailor washroom (415V 0.37 KW) 63 Overhauling of following motors to be carried out as per instruction mentioned in technical requirement. (Spares contractor Supply) 64 Name of MotorSpecification Make 65 FW LT circulatingpump Motor for DA & 415V,3-Phase, 50 Hz, 15 KW M/s Brook CromptonME ( LT-1,2,3 & 4) 66 FW LT circulating pump motor (Back up)415V,3-Phase, 50 Hz,22 KW M/s MEZ 67 ME & DASW cooling Pump Motor415V,3-Phase, 50 Hz, 15 KW M/s Brook Crompton 68 FollowingStarterPanels(M/sMarineElectricals)tobeoverhauledasperinstruction mentioned in technical requirement. Overloadrelays(16-24Amp)tobecalibratedandCalibration certificate to be provided. 69 Name of Control Panel 70 FW LT Circulating pump Motor (Back up) 71 FW LTcirculatingpump Motor for DA & ME (LT-1,2,3 & 4) 72 ME & DASW cooling Pump Motor 73 Overloadrelays(16-24Amp) 74 GALLEY OVEN-02 NO. M/S DENKI 75 Overhaulingof electricovenstobecarriedout.Overhaulingincludesthe following:-(a)Examine contactors for carbon deposition and pitting.(b)Check Insulation of control transformer, power supply wiring.(c)Renew all heat proof cables of oven terminal to hotplate terminal posts along with porcelain sleeves from terminal post to hot plate terminal.(d) Check and prove function of thermostat. (Mat &Spares contractor supply) 76 HOT PLATE (GALLEY EQUIPMENT) MAKE: M/S DENKI 77 Following defects observed in hot plate range :- 78 Insulation of heat proof cable pertaining to hot plates found low (approx. length : 50 mtr) to be renewed with 06 no. ceramic connectors. 79 Heat proof Single core control cable from JB to main terminal deteriorated. Same to be renewed. (approx. length: 15 mtrs). 80 Renewal of rotary switch 81 300 LTRS HOT WATER CALORIFIER, M/S DENKI QTY - 02 no. (Location- AC Compartment) 82 Undertake the following routines:-(a)De-scale the heater.(b)Test heater, thermostat for proper insulation resistance etc.(c)Fill water, ensure all parts are watertight and leak proof.(d)Overhaul 02 no. control panel.(e)Clean and paint all parts necessary to prevent rusting.(f) Usenewpacking,gasket,washerswhilerefittingtheapparatusplate,pipe connections.(g)Ensure all electrical components are fixed correctly and wiring connections are appropriate as per terminal markings.(h) Renew Earthing strip.(j) Check the insulation resistance of complete unit including control panel before commissioning of Calorifier. 83 Hot water circulating Pump (monoblock) along with motor (415V, 3-phase, 50 Hz, 0.37KW, M/s Garbaino, Italy) to be overhauled as per instruction mentioned in technical requirement.(Bearing No 6201-ZZ/C3). 84 DRYING TUMBLER CONTROL PANEL &MOTOR M/S STEFAB INDUSTRIES LTD, 85 Drying Tumbler Motor (415 V, 3-ph, 1.5 KW, 02 no.) to be overhauled as per instruction mentioned in technical requirement.(Bearing no- 6204 C3) 86 Drying Tumbler Control Panel to be overhauled as per instruction mentioned in technical requirement. Calibration of 02 no. over-load relays (TDR, 18 A – 25 A) to be carried out. Calibration certificate to be provided. (Spares contractor Supply) 87 Washer Extractor Motor (415V, 3-Ph, 7.5 KW) to be overhauled. Check electromagnetic clutchs gap and ensure it is not more than 0.5 mm. Replace V-belt. (Bearing No – 6306 - ZZ & 6208 - ZZ) (Spares contractor supply) 88 LaundryWasherExtractorcontrolpaneltobeoverhauledasperinstruction mentioned in technical reuirement. (Spares contractor Supply) 89 WATER TIGHT SLIDING DOOR (MAKE: GODREJ), QTY-10 NO. 90 Control panel of watertight sliding door to be overhauled and system to be proved for satisfactory operation. 91 WATER MIST SYSTEM (M/s GRUNDFOSS, HUNGARY) 92 Motor (415V, 3-Phase, 5 KW) to be Overhauled as per instruction mentioned in technical requirement. 93 Starter Panel (at ASP) and Control Panel in DCHQ to be overhauled asperper instruction mentioned in technical requirement.InadditiontothiscalibrationofO/Lrelayandactivationof water mist system from all the 07 locations to be proved. 94 FOAM LIQUID TRANSFER PUMP MOTOR (M/S GRUNDFOSS)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
West Bengal View Result →
50.
Defence #10735412 AOC
Tender For Comprehensive Maintenance Of Otm Accn At Dscc Under Ge Dronachal; 1 Demolition of Brick or Stone Masonry built in cement mortar etc completecomplete all as specified and directed. 2 M & L for brickwork with Fly ash Bricks, in straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and as directed by the Engineer-in-Charge 3 M & L for brickwork with sub-class `B` bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and as directed by the Engineer-in-Charge 4 Demolition of cement concrete in ground floor, (unreinforced) paving nexc 15 cm thick (below or above GL) incl tiling if any complete all as specified and directed 5 M&L forcement concrete 1:4:8 type D-2 (using 40 mm graded stone agg) as infoundation, filling, subbase and mass concrete complete all as specified & directed. 6 M & L PCC (1:3:6) type C-2 using 40mm graded stone aggregate 75 mm thick as in plinth protection finished fair even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed 7 Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed. 8 M & L for Non-Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tiles exceeding 0.11sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with colour of tiles over and incliding screed bed 15mm in CM (1:4) complete all as specified and directed. 9 M&L glazed ceramic colour tiles, in vertical surfaces350x 250x 7 mm/ 450X 350X 7mm thick thick set and jointed in neat cement slurry and pointed in white or colou cement to match fixed over 10mm thick CM (1:3) as in backing coat complete all as specified and directed. 10 M&L for Vitrified ceramic coloured light shade 10mm thick(square/rectangular) polished,area of each tile not exceeding 0.36 Sqm as in floors over and including 20mm thick screed bed in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shades of tiles complete all as specified& directed 11 M&L for Vitrified ceramic coloured light shade 10mm thick(square/rectangular) polished,area of each tile not exceeding 0.36 Sqm on vertical surfaces such as skirting, dado and risers to steps etc over & including 10 mm thick rendering in CM 1:4 set& jointed in neat cement slurry & pointed in white or coloured cement to match complete all as specified & directed. 12 M&L Sand filling under floor/pavementor in foundation including watering and consolidation 13 M&L machine pressed precast concrete interlocking paver block in any shape and size confirming to IS-15658-2006of 60 mm thickness M-35 grade with grey cement andpigment (reflective type) complete all as specified and as directed. 14 M&L Granite of 20mm thick (of any type and colour) work (table rubbed/grinding/ moulding and polished) in steps,jambs,pillars, window cills,cooking platforms, wash basin counter and likeover and icluding 20 mm screed bed in CM 1:3all as specified and directed. 15 M&LPCC 1:2:4 type B1(using 20mm graded stone aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs, mass filling/ levelling coarse as it bedding coarse and the like including weathering, slightly rounded or chamfered angles and throating, as directed complete all as specified and directed 16 M&L for Taking down of cement plaster in any description on brick or stone wall etc., incl hacking out joints for key scrubbing down with water etc. all as specified and directed 17 M&L for 20 mm thick rendering in CM 1: 4 on faces of brick or concrete surface, shall be done in two coats comprising 5mm thick in CM 1:4 mixed with water proofing compound @3% by weight of cement and over a backing coat of 15mm thick in CM 1:4and finished with trowel to an even and smooth surfaces without using any extra cement complete all as specified and directed.Note : Water proofing compound shall be measured and paid in respective item 18 Supply only Integral water proofing compound 19 M&L for 15 mm thick renderingbrick or concrete surface in CM 1: 6 finishing the surfaces fair & even without using extra cement complete all as specified and directed. 20 M&L for 10mm thick rendering onfair faces of brick or concrete surface in cm 1:3 finishing the surfaces fair & even without using extra cement as in ceiling complete all as specified and directed. 21 M & L Preparation of new plastered surface wall and applying two coat of Exterior weather proof water base emulsion paint over a coat of white cement basedputty complete all as specified and directed. 22 M & L for preparation of newly plastered surfaces of wall and applying two coats of acrylic washable distemper over a coat of chalk whiting, on plastered surfaces, preparatory to distempering complete all as specified and directed by the Engr-in Charge. 23 M&L for prepration of new ceiling surfaces, applying 3coat of white wash on ceiling all as specified. 24 Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exc. 1.5 sq. m each complete all as specified and as directed by the Engineer-in-Charge 25 Taking down chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sq. m but not exc 4 sq. m each complete all as specified and as directed by the Engineer-in-Charge 26 Taking down and re-fixing of old aluminum doors Shutter in same opening with necessary required repairs and fittings including galss rubber bedding door frame rubber bedding and glazing clips(Glass pan, floor hydraulic spring handles, mortice lock and tower bolt will be measured and paid separately) area exc 1.50 sqm but n.exc 4.00 sqm each 27 S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supplying and fixing in opening as per specification and drawing complete all as specified. 28 Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails.MS frame shall be covered with heat moulded plain colour PVC C channel having a PVC sheet strip of 20mm width stuck inside with solovent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in M.S. frame welded sealed to the stiles and rail with suitable PVC sheet beading and jointed together with solvent cement supply and fixing in the frame at site as per specification and drawing. 29 S&F Powder Coated (minimum thickness of powder coating 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.complete all as specified and as directed. 30 Hacking out old glass (any thickness size quality or description) from wooden frame or stone, concrete or brick surrounds glazed with putty or fixed with beads all as specified and directed. 31 S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and directed 32 S&F 4.8 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc .50 sqm in each panels complete all as specified and directed 33 M&L12mm thick Prelaminated particle board, exterior grade,prelaminated both side with decorative choice lamination , fixed to aluminium door, partitions complete all as specified and as directed. 34 S&F in repairs galvanised mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperure 1.180 mm and fixed and with tinned tacks or galvanised wire staples, complete all as specified. 35 S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kgaluminium extruded section body complete all as specified and as directed. 36 S&F for floor door stopper of 140mm long cover plate of aluminium alloy body and tongue anodised with hard drawn steel spring, fixed in floor complete all as specified and directed 37 S&F for 150 mm aluminium handles, cast type, anodised complete all as specified. 38 S&F for ISI Marked 200mm long aluminium, anodized, barrel tower bolts of extruded section complete all as specified. 39 S&F 300mm long aluminium allooy anodised sliding door bolts with hasp and staple (bolt type) & fixing clip of sheet cast or extruded section & fixing bolt & sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed. 40 S&F for 100mm Mild steel butt hinge complete all as specified and directed. 41 S&F 4-levers Aluminium Mortice lock, vertical type, size 100 mm complete all as specified and directed 42 M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed. 43 S&F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified. 44 Dismantling of wall and celing hard boards/AC sheets and plywood in any thickness & any positionincluding cover filletscomplete all as specified and directed 45 S & F Anodised aluminium snap grid of size 605 x 605mm frame work for false ceiling all as specifiedcomplete all as specified and as directed. 46 M&L Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid (Frame work for ceiling shall be measured and paidseparately) complete all as specified and directed 47 Dismantling asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as spfd. 48 Dismantling timber scantlings 40 sq. cm and over in section, for unframed work in any position complete all as specified and as directed. 49 S&F steel work as in rafter, purlins, posts tubular (round/square/rectangular shape of pipes as approved by Engr-In-Charge) including postspecial shaped washers etc complete incl necessary nut bolts wind ties and gusset plates etc using ERW or induction butt welded tubes conformining to IS 1161-1998 grade St-240 Complete all as specified and as directed. 50 S&F pre- painted galvalume aluminum zinc coating GI Based corrugated steelsheeting 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas,fixedwith self tapping screws complete all as specified & directed 51 S&F in repair 6mm thick coloured polyicarbonate sheet (ISI marked) with shelf drilling steel screw with washer on roof and joint of two sheet will be filled with silicon weather proof sealent and cover with aluminum strip of size of 50x3 mm top and bottom and fixed with shelf drilling steel screw with washer on roof complete all as specified and directed. 52 S&F in repair for 3 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with bolts and washer in roof, wall etc complete all as specified. 53 Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 54 Supplying and laying of GI tubing Dia 15mm medium weight incl fittings on walls / ceilings or Laying in floors complete all as specified. 55 Taking up or down 20mm mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 56 Supplying and laying of GI tubing Dia 20mm medium weight incl fittings on walls / ceilings or Laying in floors complete all as specified. 57 Taking up or down 25mm mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified. 58 Supplying and laying of GI tubing Dia 25mm medium weight incl fittings on walls / ceilings or Laying in floors complete all as specified. 59 S&F 25mm bore gun metal, globe or gate valve with iron wheel head, screwed both ends for iron pipes and fixed complete all as specified and directed. 60 S & F in repair of ISI marked 15mm bore stop valves/angle valve concealed fancy type cast copper alloy, chromium plated with long shank and cup , screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified. 61 S&F 15 mm Pillar taps, cast copper alloy, chromium plated fancy type, chromium plated, screwed down high pressure, with or without letter hot or cold with long screwed shanks and fly nuts, screwed for iron pipe and fixing complete all as specified and directed by engr in charge.Make : Prayag or equivalent 62 Supply and fixing in repair for ISI marked 15mm bore, fancy type bib tap of chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed by the Engineer-in-Charge. 63 S & F in repairs Brass chromium plated shower rose 125mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and as directed. 64 S & F for in repair soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed by the Engineer-in-Charge 65 S&F brass chromium plated tubular towel ring complete all as specified and as directed by the Engineer-in-Charge 66 S & Fbrass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed by the Engineer-in-Charge 67 S&F in repair for vitreous China wash basin, white, flat back, size 450x300mm including PVC connections 15mm size with PTMT nuts of length 450mm,waste coupling, 40mm pvc waste pipe of suitable length, brackets,and cutting for and pinning in ends of brackets or erecting stand complete all as specified and as directed by the Engineer-in-Charge. 68 S&F in repair vitrous china white oval type under counter WHB of size not less than 195x600x425mm of first quality fixed all as specified and directed. 69 S & F in repairs Vitreous China squatting pan, `Orissa` pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PVC SWR P or S trap complete all as specified and as directed by the Engineer-in-Charge. 70 S&F in repair vitreous china wash down water closed pan (pedestal Pattern), white (excluding fixing bolts, flushing cistern and flush pipe) and including plastic seat cover complete all as specified and directed. 71 Supply and Fixing in repairs for 10 ltrs capacity PVC Valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets flushing cistern, PVC flushing pipe of suitable length and PVC connection 450mm long. complete all as specified and as directed by the Engineer-in-Charge 72 S&F in repair Vitreous China Urinal, Half stall type,white (excluding flushing cistern, flush pipe and waste pipe) including urinal spreader complete all as specified and directed. 73 S & F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to wall with PVC clamps complete all as specified. 74 S & F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floorss complete all as specified. 75 Supply & Fixing repair PVC Bath Cabinet mirrorcomplete all as specified and as directed by the Engineer-in-Charge 76 S&F in repair brass CPwall mixer for mixinghot and cold water screwed down for iron pipe and fixed. 77 S&F in repair brass CP centre hole mixer for (WHB) mixinghot and cold water screwed down for iron pipe and fixed 78 S&F in repair waste coupling 40mmsuitable size for kitchen sink of PTMT (half or full threaded) complete all as specified and directed 79 S&Fin repair40mm bore PVC waste pipe for kitchen sink one mtr long complete all as specified and directed. 80 S&F in repair 32mm bore PVC waste pipe for wash basin one mtr long complete all as specified and directed. 81 S&Fin repair 100mm dia CPgrating (Minimum weight 25 gms) all as specified and directed. 82 S&Fin repair PVC connection 15 mm size with PTMT nuts of length 600 mm all as specified and directed. 83 S&F in repair Plastic water closet seat,closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. 84 S&F in repair 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as spfd & directed 85 S&F in repair for replacement of Jet spray with holder on EWC in repairs all as specifie and directed complete Make : As per sample approved by GE 86 S&F in repair health faucets CP with 1.2 mtr long CP flexible pipe complete all as specified and as directed. 87 S&F in repair two way C.P. Bib cock 15mm dia complete all as specified and as directed. 88 Dismantling water tank capacity exc 500 ltrs but nexc 1000 ltrs and removing to stores complete all as specified and directed 89 Hoisting & Fixing 500 Ltr rotational moulded polyethylene water stotage tanks(cylinderical verticle with closed top) hoisted & fixed in position complete all as specified and directed. 90 Hoisting & Fixing 1000 Ltr rotational moulded polyethylene water stotage tanks(cylinderical verticle with closed top) hoisted & fixed in position complete all as specified and directed. 91 M & L for preparation of old plastered surfaces of wall and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required sharde & colour, as per manufacturers specification over a coat of 1mm thick putty complete all as specified and directed by the Engr-in Charge. 92 M & L for preparation of old plastered/unplastered surfaces of Ceiling and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required sharde & colour, as per manufacturers specification over a coat of 1mm thick putty complete all as specified and directed by the Engr-in Charge. 93 M&L for preparation of old plastered/unplastered and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces and providing and applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. 94 M&L preparation of old surface of ceiling and applying Two coat white wash complete all as specified and as directed 95 S & F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame with5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified 96 M&L Preparation of old decorated surfaces of wall/ceiling including brooming , scraping down. Smoke spot, moss, efflorescent salts, trading oil, grasy spotsand removing stopping nails and applying two coat of plastic emulsion on walls/ceiling over primer and a coat of 1mm thick white cement based wall care putty all around including complete sanding of existing surface treatment with sand paper or iron patti / flat / mechanical sanding machine complete all as specified and directed. 97 M&L for Preparation of old painted surfaces of Steel/ steel based materials exc 10cm width or girth and applying one coat of synthetic enamel paint as directed and specified. 98 M&L for preparations ofold wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paints all as specified and directed. 99 Waterproofing of terrace with Dr. Fixit HydroShield PUD Plus OR Asian SmartCare PU Magnaum Product code 5662 OR Berger PU RoofKoat 100 (A) Surface Preparation(i) All surfaces should be dry and free from contamination such as oil, grease, loose particles, decayed matter, moss, algal growth, laitance and all traces of shutter release oils and curing compounds.(ii) All loose and de-bonded concrete/ screed shall be removed and proper repairing to be carried with polymer modified mortar. Washing the roof-terrace surface and making it dust free.(iii) The careful sealing of existing cracks & joints before the application is extremely important for log lasting waterproofing results. Clean concrete cracks / hairline cracks, of dust, residue or other condemnation. Fill all prepared cracks with acrylic flexible crack filler Dr. Fixit Cracks-X Paste OR Asian SmartCare CrackSeal OR Berger Homeshield Crackfill Paste.(iv) Cracks more than 5mm fill all repaired with Polymer modified cement sand mortar in the ratio of 1:3 duly admix with Dr. Fixit Pidicrete URP OR equivalent product in Asian Paints OR Berger Homeshield Latex Plus @ 10% by weight of cement.(v) Pre wet the surface prior to application of primer and allow surface water to evaporate to make surface saturated dry (SSD) condition 101 (B) Bond Coat(i) Applying Dr Fixit Pidicrete URP OR equivalent product in Asian Paints OR Berger Homeshield Latex Plus a SBR latex based bonding chemical used for repairs & waterproofing, at a ratio 1:1 one part chemical one part cement. Make sure bond coat is done properly and spreader evenly to the entire surface with brush or roller. 102 (C) Pre-Coat Application(i) Applying one coat of Dr. Fixit Pidicrete URP OR equivalent product in Asian Paints OR Berger Homeshield Latex Plus with cement @ 1:1.5 one part chemical, one and a half part cement and lay 45 GMS fiber mesh on still wet coat of URP. Make sure fiber mesh sticks to the surface evenly. 103 (D) Primer Application(i) Apply one coat of acrylic based primer Dr. Fixit Primeseal Primer OR Asian PU Magnum Resin & Asian PU Magnum Hardner OR Berger SealOPrime (diluted with water in the ratio of 2:1) spreading at the rate of 8-10 /Sq.mt /Litre. Allow the primer to air cure for 4-6 hours.(E) Coating Application(i) Stir well before use. Apply 1st coat of Dr. Fixit HydroShield PUD plus OR Asian SmartCare PU Magnum Product 5662 OR Berger PU RoofKoat without dilution spreading at the rate of 0.70/litre/Sq.mt/Coat until all surface is covered. 104 (E) Coating Application (Contd(ii) Allow the first coat to dry for approximately 4-6 hours before applying the 2nd coat at 90° to the first coat and 3rd coat at 90° to the second coat. Ensure there are no pinholes or air bubbles on the membrane surface. (iii) Apply second coat of Dr. Fixit HydroShield PUD Plus OR Asian SmartCare PU Magnum Product 5662 OR Berger PU RoofKoat without dilution spreading at the rate of 0.70/litre/Sq.mt/ Coat. Ensure there are no pinholes or air bubbles on the membrane. (iv) Apply third coat of Dr. Fixit HydroShield PUD Plus OR Asian SmartCare PU Magnum Product 5662 OR Berger PU RoofKoat without dilution spreading at the rate of 0.70/litre/Sq.mt/ Coat to achieve total dry film thickness of 800 to 1000 microns at forced coverage @ 2- 2.1 /litre/Sq.mt in 3 coats. Ensure there are no pinholes or air bubbles on the membrane. (v) Make sure glass fibre mesh is completely embedded. Surface should be smooth after the application. Check to see no void surface is left untreated / uncoated.(vi) All the concrete / masonry pedestals present on the roof, constructed for supporting the water tanks or pipe lines or dish antenna/solar panel, etc., also should be coated with extra coat of same material incorporating reinforcing fabric.(vii) Allow the system to air cure for 7 days prior to carry out ponding test.Note:- System comes with 10 years waterproofing warranty from Manufacturer or Authorized Applicator. 105 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and as directed. 106 M&L for point wiring with and incl 1.5 sqmm (nominal area) PVC insulated multi-stranded copper conductor FRLSH in and incl PVC casing and capping ISI marked 20/30 mm size or as required at site incl with its fittings and fixture such as tees, bends, elbows and juction boxes all moduler type surface mountingetc with 1.5 Sqmm copper conductor cable green in colour as earth continuity conductor connected to main earthing and common earth terminal complete all asspecified and directed.Note :- Modular PVC Surfacemounting boxes and for mounting switch ,socket withmodular frame plate and covercomplete all as specified and directed 107 (a) One light/Fan/Exhaust fan point controlled by one switch. 108 (b) One 3 pin socket outlet 5 Amps on independent board. 109 (c)One 3 pin socket outlet on same board. 110 M&L for wiring complete 2.5 Sq.mm single core multi standard copper conductor FRLS PVC insulated 650/1100 Volts drawn through non metalic rigid PVC casing capping including necessary accessories like bends lees and elbows etc fixed on wall/ceiling including sunken type pressed steel terminal boxes of suitable size with plastic laminated white/coloured top sheet cover 2 mm thick including 1.5 Sq.mm FRLS PVC insulated copper green wire for earth wire complete for 3/5 pin 15 Amps switch socket combination complete all as directed by Engineer-in-Charge. 111 S&F in repairs modular switch flush single pole one way 6 Amps. 112 S&F in repairs socketmodular outlet 5 pin with gang box 6 Amps 113 S&F in repairs socket modular outlet 5 pin 15 Amp with gang box multipurpose. 114 S&F in repairs modular switch flush single pole one way 15/20 Amps. 115 S&F in repairs sheet metalsingle pole and neutral encloserwith a two pin and earth plug and socket complete with one MCB SPN 20 amps, 240 V. 116 S & F in repairs Modular AC Box With 20A SP MCB, Metal Enclosure & Unbreakable Heavy Duty With ISI Plug Top 117 Supply and fixing in repair of MCCB forDPX 415 Volts 100 Amps 4 pole with breaking capacity of 25 KALegrand/ Schinider/ C&S 118 Supply & Fixingin repairs MCB DB TPN 415 Volts 200 Amps rated bus bar having 4 way single door shutter. 119 Supply & Fixingin repairs MCB DB SPN240 Volts 200 Amps rates bus bar having 4 way double door shutter. 120 Supply & Fixing in repairs MCB DB SPN 240 Volts 200 Amps rates bus bar having 8 way double door shutters. 121 S&F in repairs MCB TPN 415 Volts of capacity 63 Amps complete all as directed by Engineer-in-Charge. 122 S&F in repairs MCB SPN 240 Volts of capacity 40 Amps complete allas directed by Engineer-in-Charge. 123 S&F in repairs MCB SP 240 Volts of capacity 5 to 30 Amps complete allas directed by Engineer-in-Charge. 124 S&F sub main wiring4 Sqmm with three runs of 4 sqmm single core multi stranded copper conductor in PVC conduit including all fitting fixed on wall/ceiling including4 Sqmm PVC insulated copper earth wire connected to earth including taking down, complete all as directed by Engineer-in-Charge. 125 S&F sub main wiring6 Sqmm with three runs of 6 sqmm single core multi stranded copper conductor in PVC conduint including all fitting fixed on wall/ceiling including6 Sqmm PVC insulated copper earth wire connected to earth including taking down, complete all as directed by Engineer-in-Charge. 126 Supply & fix in repairs recess mounted LED 15 Watt Ultra slim recess-mounting round LED downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat-dissipating fins for larger surface area finished in epoxy powder-coated white to deliver high-efficacy light output and uniformity, utilising edge-lit technology. 127 Supply & fix in repairs ceiling mounted LED light fitting 36 Watt Recess-mounting ultra-slim LED 2x2 edge-lit tile in aluminium extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as directed by Engineer-in-Charge. . 128 Supply & fixin repairsceiling mounted LED light fitting 36 Watt surface panel ultra-slim LED 2x2 edge-lit tile in aluminium extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as directed by Engineer-in-Charge. . 129 S&F in repairs LED flood light fitting 150 watt LED floodlight luminaire High-efficiency IP65 innovative LED floodlight with pressure die-cast aluminium housing and toughened glass in the front with unique flood optics to ensure uniform distribution and savings upto 50% as compared to conventional system 130 Supply & fixin repairs Wall mounted LED - 20 W Linear Aluminium High Lumens output LED batten made from aluminium extruded channel, powder coated with opaque diffuser for glare free light complete with accessories all as specified and directed. 131 Supply & fix in repairs Wall mounted LED batten 10 watt LED - Linear Batten made from Polymer extruded channel, with opaque diffuser for glare free light, complete with accessories all as specified and directed. 132 S&F in repairs LED lamp 9/10 W, 230VAC, 50Hz, cool white single phase with all fitting and fixing accessories complete all as specified and directed. 133 S&F in repairs LED inverter lamp 20 W, 230VAC, 50Hz, cool white single phasewith all fitting and fixing accessories complete all as specified and directed. 134 S & F in repairs modular stepped type electronic fan regulator flush type on the existingphenolic laminated sheet etc. as reqd 135 S&F in replacement piano type switch single pole 230 volt flush type 5 Amps 136 S&Freplacement piano type switch single pole 230 volt flush type 16 Amps.(Normal switch) 137 S&F in replacement switch socket combination withpvc gangbox 6/16 Amp as per existing ISI mark.(Normal type) 138 S&F in replecement switch socket combination with pvc gangbox6 Amp as per existing ISI mark. 139 Supply and fixing in ,replacement ELCB 63 Amps, 4 pole 140 S & F in repairs Modular Metal flush box 3 module 141 S & F in repairsModular White cover plate 3 module 142 S & F in repairs Modular Metal flush box 6 module 143 S & F in repairsModular White cover plate 6 module 144 S& Fin replacement of PVC 3 Pin plug top 15 Amp complete as specified 145 S& Fin replacement of PVC 3 Pin plug top 5 Amp complete as specified 146 S&F energy saving and enviornment friendly long life LED security light fitting 1 x 36W LED, versatile, pressure die cast aluminium IP-66 protection with high power LED as light source and arcylic cover etc incl all accessories prewired complete including mounting on bracket and necessary connection to ceiling rose etc & suitable bolts and nuts with washers, connecting with PVC insulated multi stranded copper flexible cable of size 0.5 Sqmm three core from ceiling rose to fittingincluding taking down the old one, complete all as specified and directed. 147 M & L for Servicing of1200/1400 mm ceiling Fan by dismantling carefully and taking out unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes and painting including replacing of un serviceable part like bearing gun metal bush condensor of suitable capacity and re-assembling the same and complete all as directed by Engineer-in-Charge. 148 M & L for Servicing of 250/300/350mm Exhaust Fan by dismantling carefully and taking out unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including replacing of un serviceable part like bearing gun metal bush condensor of suitable capacity and re-assembling the same and complete all as directed by Engineer-in-Charge. 149 Supply and fix building security light bracket, bend to 120 degree angle, made out of 32 mm bore, galvanised iron, light grade tubing (approx 1.2 mtr in length) including necessary two nos suitable size of clamps with nuts, bolts and washers, etc.and two coats of synthetic enameled paint over a coat of red oxide primer including taking down the old unserviceable one complete all as specified and directed. 150 Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx 6.3mm thick buried direcly in ground vertically to a depth not less than 2.25 meters below normal ground level with the top edge of earth plate not less than 1.5 meters below ground level connected to galvanized iron wire of4 mm dia by means of bolts, nuts, check nuts and washers made out of galvanised iron or steel and earth wire protected by galvanized pipe light grade 40 mm bore and thorugh test point including necessary earth work and excavation in any type of strata, andGI light grade 20mm bore watering pipe with funnel and wire mesh, PCC 1:2:4 type B1 chamber with 40mm thick RCC 1:2:4 type B1 design mix cover slab with 6mm kdia MS bars at 100mm c/c both ways with MS Hook 6mm dia MS bars etc complete 151 M&L earthing complete with copper plate of 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level withcopper strip 20 x 3 mm as earthing lead including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixedin continuous layer 15 CM all around the plate and balance pit will be filled with vigitable soil approved byengineer in charge, PCC (1:3:6 ) type C1 in chember ,Precast 50 mm thick in cement ( 1: 2:4) type B.1 with CI framewith cover, 20mm dia bore light grade GI watering pipe furnel etc fixing of GI Pipe of suitable size protection for earthing lead from earth pit to test point complete & making connection 152 M&L for installing and commissioning Copper coatedChemical Earthing electrode oflength 3 mtr, inner dia of 40 mm and outer pipe of dia 76 mm with minimum thickness of 250 micron, after boring 20 metre deep, 150 mm in diain hard/soft soil with help of boring machine,filling the bore hole withblack cotton soil upto 17 mtrs level i.e below the electrode bottom level, filling remaining portion by pouring suitable chemical bentonide compoundduly mixed with water and filling earth enhancement material (minimum approx. 30 kg) into the augured hole in slurry form and allowed to set, covering of the composite structure (earth electrode + earth enhancement material), covering remaining portion with backfill soil/ material, welding copper strip with existing head of earth electrode including necessary PCC earth pit work and including all necessary nut, bolts, washers etc complete 153 Taking down unserviceable geysers of any capacity and make from each location by disconnecting and sealing all electrical and water lines for annual maintenance/servicing. Overhauling, dismantling the same for repair/replacement of unserviceable parts, including brazing to inner tank, cleaning, taking out sludge from inner tank and washing with cleaning solution and reassembling and refixing the same in each original location/ position, connecting all electrical and water connections including provn of 2.5 Sqmm 3 core sheathed multi-stranded copper conductor flexible cable from connector block to geyser and testing complete all as specified and directed. (NOTE (a) New parts shall be measured and paid separately under Supply only rates here-in-after. (b) Minor parts, if any, not mentioned in the schedule but required for smooth functioning of geysers are deemed to be included in the rate of the item.) 154 Supply only PVC inlet pipe, 15mm bore, 450 long including both end check /end nuts and washers. Make 155 Supply only PVC steel braided outlet connection pipe, 15mm bore, 450 mm long including both ends check nut & washer complete. 156 Supply only heating element of any type 1500 Watts. 157 Supply only heating element of any type 2000 Watts. 158 Supply only thermostat of any type suitable for 25 ltrs capacity geyser. 159 Supply only internal assembly complete with packing ring, bolts, nuts & washers suitable for 25 ltrs capacity geyser. 160 Supply only thermal cut off ISI marked suitable for 50/35/25 ltrs capacity geyser. 161 Supply only fusible plug made of brass having lead alloy fuse suitable for 25 ltrs capacity geyser. 162 M & L for painting geyser of capacity 25 ltrs complete, in situ, with two coats of synthetic enamel paint, white, by spraying including filling cavities with filler, denting after scrubbing down old paint using emery paper, cleaning, washing etc. and writing MES No complete all as specified and directed. 163 S&F in repairs change over 32 Amps 4 pole 415 V complete all as directed by engr-in-charge. 164 S&F in repairs change over 63 Amps 4 pole 415 V complete all as directed by engr-in-charge. 165 Attending daily complaints of DSCC and 14 Acre land area by deputing adequate number of Skilled teams of qualified Electrician and helper any time of the day ( Minimum 01 Skilled Electrician & 02 Helper ) for repair / tightening of end terminals of street light fitting, Flood light, LED strip on poles , High Mast light , Post top lanten of any size/capacity at anyheightand repair the street lights, Flood lights and Post Top lanten having minor faults i.e loose connections, carbon deposition , Shiftingand refixing the same etc and makethe light functional.After rectifying the defects of the electricalsystemreplace the U/S items such as street light , flood lights, LED strips, MCBs TPN ,connection plate , thimbles and timmersmall pieces of electrical cables PVC insulated copper multistranded conductor of sizes 2.5 Sqmm to 6 Sqmm twin core and length not increasing 1.5 mtrs completeall as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill) and In Addition one 16 mtrs hight hydraulic vehicle with driver & operatorof the same team will opearte and manage day to day street light Complaints and update the status of complaints on daily basis and confirmed throgh concerned JE E/M daily as per directed by Engr-in Charge. 166 Note:- (i)Complaint shall be done within 24 hrs afterintimation by JE E&M Engineer-in-Charge failling whichpenalty of Rs 250 per day per complaint will be levied on contractor.(ii) One supervisorwill report to JE E/M , Engineer -in-Charge on daily basis with complaint register. (iii) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis ( Format as per provided by the Engineer in Charge.(iv)This item pertains to attending complaints ofstreet light/flood light/LED strips on poles/High mast, MCB, & timer panel including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge.(v)Items shall be measured and paid seperately under respective item of Sch A 167 S&F in repair of Automatic Street Light Switch Three phase with Nature Switch-03 as the controlling unit for automatic switching of street lights based on LUX level of Natural light. The Sensor (Nature switch) along with suitable power contractor, MCB and Support Terminals should be enclosed in pole/wall mountable Enclosure made of Rust proof, Electric Shock proof, Termite proof and FR grade special moulding compound (Sintex make SMC Junction box) confirming to IP54. The contractor, MCB and circuit Wiring should suitable enough to take load5 KW equally distributed over 3 phase (4 KW/Phase). The contractor rating 25 Amps (4-pole) and MCB(single pole) rating : 20-25 Amps(SP-03 Nos), complete all as specified and directed.Make. Nature Switch Model No SWADEEP-02EC 5 KW3P or equivalent makes in Legrand/L&T/GE. 168 M & L for replacement of LED aviation light luminaries comprising of aluminium housing with polycarbonate enclosure complete Make : Bajaj/Philips/Havells complete after taking down the old unserviceable one all as directed. 169 M&L for taking down High Mast light fittings mounting on cage from High mast pole of 12.5/16/20 mtrs heightfor repairing of LED/MH light fitting of any size/type and reinstalling the fitting/cage back to its position after carrying out repairs all as directed by EIC (Cost of LED spare parts will be measure seperately) 170 M&L for rewinding ofexisting burntmotor 2 HP of high mast light fitting with replacement winding wire and refixing the same alongwith proper alingment with steel rope etcincluding electrical connection and testing complete all as directed by Engr-in-charge. 171 Supply and replacement of Existing High mast panelfront door openable with 3.0 mmthickness MS sheet of size 0.9x0.6x0.6mpowder coating paint including locking arrangement , Panel internal wiring of suitable size wire alongwith 63 Amp MCCB as incomer and 03 Nos 40 Amps MCB as outgoing and mounting on 40x40x6 mm MS angle and grouted in PCC completeincluding one coat synthetic enamel paint complete all as per directed by Engr-in-charge 172 Supply and fixingin replacementoutdoor type IP66 thermoplastic polycarbonate cable entry junction box of size 155 x 210 x 92 mm, weather proof with knockouts for cable entry- black colour with necessary cable connector link inside the box and fixing arrangement by clamp, nut bolts etc fixied on pole/ walls complete all as specified and as directed. Make - 173 Supply & fixing in replacement of new generation energy saving and environmental friendly long life LED street light 60 watt made up of pressure dia cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening separate driver compartment with IP66 protection and impact resistance of IK07by using 2 core PVC insulated cable aluminium conductor 2.5 Sqmm approx 2 m length complete all as specified and directed.Make : Havells, Cat No-ENDURAPEARLNEOL60WLED757PASYTOPC or equivalent of Philips/Jaquar. 174 S&F in repairs aluminium strip of size 25 x 4 mm fixed to wall/ pole with aluminium saddles andscrews for roof/ down conductor above ground/ buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed.Note : - Insulators/conduit/pipe shall be measured and paid separately under appropriate items here in after 175 S&F in repairs Copper strip of size 20 x 3 mm fixed to wall with copper saddles andscrews drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed.Note : - Insulators/conduit shall be measured and paid separately under appropriate items here in after 176 S&F in repairs fixing Galvanised iron strip of size 32 x 6 mmfixed to wall with Galvanised iron saddles andscrews / buried in ground/ drawn in conduit/ fixed to poles or any other indicated situation for loop earthing including connected upto test terminal point complete all as specified and directed.Note : - Insulators/conduit/pipe shall be measured and paid separately under respective item of works
Contract Date: Apr 25, 2026 Contract Value : 21.99 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 6
Madhya Pradesh View Result →
TenderDetail
Loading tenders