View Bid Results For Modbus Tenders

We found 435 Bid Results related to modbus tenders. You can find Contractor details who won modbus tenders along with contract details in Bid awards announcements section.

Filters
Stage
363
55
17
Tender Publishing Platform
192
243
State / UT
31
45
42
39
33
31
27
24
22
21
21
17
12
12
11
11
9
8
7
7
7
5
5
4
4
3
2
2
1
1
1
1
Contract Value
105
129
131
70
Publish Date
2
0
0
0
0
Sector
28
79
58
46
39
28
26
22
19
18
18
16
12
9
9
7
5
5
3
3
3
2
1
1
1
1
1
1
1
Ownership
6
180
119
86
26
22
1
Within keyword
Active filters:
Showing 1–9 of 435 tenders matching your filters
1.
Housing Urban and Rular Development #11415087 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. 35 Sqmm Size , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , -Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 105 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , -Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8400 Lpm X 30.00 M Head (At Mbs) , Ns Item -Design, Construction, Erection And Commissioning Of 1 Ranneywell (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 30 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 1.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
3.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
5.
Steel #11302303 AOC
Bids Are Invited For Pm5630-2 Eth-Ac500 Plc 8 Mb 24 V Dc 2Xethernet 1Xrs232-485 Can Sd Card Slot Lcd Display Manufacturer-Abb India Limited Type-Pm5630-2 Eth Catalogue No-1Sap131000R0378 , Tb5600-2Eth-Ac500 Terminal Base Oxslot 2Xethernet Rj45 1Xcom 24 Vdc Can Connector Spring Terminals Manufacturer-Abb India Limited Typeormodel- Tb5600-2Eth Abb Catalogue Number-1Sap110300R0278 , Mc5102- Micro Memory Card 8 Gb For Program Data Or Firmware Update With Adapter -1 Manufacturer-Abb India Limited Article No- 1Sap180100R0002 , Ax522 Analog I-O Module 8 Ai-8 Ao U-I-Pt 10012 Bit And Sign 2-Wire Manufacturer -Abb Catalogue No-1Sap450000R0001 , Ai523- Analog Input Module 16Ai U-I-Pt100 12Bitandsign 2-Wire Manufacturer-Abb Type - Ai523 Article No-1Sap250300R0001 , I-O Terminal Unit Tu515 24 Vdc Screw Terminals Abb Cat Number1Sap212200R0001 Manufacturer-Abb Typeormodeltu515 , Digital O-P Module Mm-Do524 Do524-S50 Digital Output Module 32 Do Do-Transistor-24Vdc 0 Point 5A 1-Wire Manufacturer-Abb India Limite D Typeormodel-D0524 Article No-1Sap240700R0001 , Lithium Battery Ta521 Part No-Ta521 Catalogue No1Sap 180 300 R0001 , Bus Module-1Sap222200R0001 Abb Ci522-Modtcp-S500 Bus Module 8Dc-8Di-8Do 24Vdc Di-Dc-24Vdc Do-Dc Modbus Tcp Pn1Sap222200R0001 Make- Abb , Terminal Unit Sap214000R0001 Abb Tu508 Eth Ethercat I-O Terminal Unit 24 V Dc Spring Terminals Pn -Sap214000R0001 Make- Abb , Hmi Control Panel 15Ench Tft , Digital Input Module 32Di 24V Dc 1 -Wire Digital Input Module 32Di 24V Dc 1 -Wire Manufacturer -Abb India Limited Type-Model -Di5 24 Abb Article Number1Sap240000R0001 Total Quantity : 21
Contract Date: Ref. Documents Contract Value : 4.89 Lakh
Boards / Undertakings / PSU No of Bidders 6
West Bengal View Result →
6.
Civil Aviation #11297332 AOC
Bids Are invited for Annual Maintenance Contract of Fire Hydrant including all pumps, panels, cables, piping , Hydrants etc. , intelligent type analogue addressable Fire Alarm system and Sprinkler system including all pumps, panels, cables, piping, sprinklers etc. at Aurangabad Airport for all preventive maintenance and checks as per manufacturers manual including attending to complaints/ Faults/ break down and taking rectification action, ensuring serviceability/ satisfactory working conditions of the system, maintenance of all records, documentation etc. as per the detailed specifications, terms & conditions covered under this contract on all days including sundays and holidays as per requirements of AAI. , Annual maintenance contract of Kirloskar make DG pump set (with specification mentioned under (A)) i/c engine control panel and other accessories of DG pump set.Job includes monthly visits for carrying out preventive maintenance, attending any number of breakdown calls when required, carrying out B and C check, minor repairs etc. as per manufacturers recommendations / standard practice and as per the scope of work, complete as required. A) Engine type - 6R1080, Rating - 79 hp, RPM - 1500, governing class - M2. , Supplying, installation, testing & commissioning of Conventional Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of addressable Photo Electric Smoke detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required. (Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supplying, installation, testing & commissioning of Conventional Multi Sensor detector with builtin LED and mounting base complete with all connections complying to relevant IS etc. as required.(Approved Makes : APOLLO/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLY IAS). , Supply, Installation, Testing & commissioning of UL / EN listed (latest version) intelligent addressable multi criteria detector {Smoke + heat } with inbuilt fault isolator / isolator base and with unique optical sensing chamber, visible LED, fully coated circuit board, superior RF / Transient protection suitable for 2 wires loop connection, complete with plug into common separate base & housing constructed of LEXAN (or polycarbonate) complete with connections etc. as required and to be installed below / above false ceiling roof and concealed space and as per enclosed specifications ,complete as required. (Cost of plug in common base shall deemed to be included in cost of detectors) , Supplying, installation, testing & commissioning of conventional manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc.complying to relevant IS etc. as required.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. complying to relevant IS etc. as required. (Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning fire alarmsounder with facility to make announcement, mounted in M.S.box (16 SWG) with hinged cover plate & suitable for operationwith amplifier i/c line matching transformer etc. complete asrequired.(Approved Makes : APOLLO/EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ MORLEY IAS/SYSTEM SENSOR/GROUP4/ MINIMAX). , Supplying, installation, testing & commissioning of conventional fire alarm panel , 16 X 2 dotmatrix LCD display, suitable for eight zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all otherstandard facilities as per IS:2189, complying relevant national fire alarm code for local fire alarm system with mimic diagram for allarea/zone covered, complete with all connections. The panel shall have input of 240 volts AC power supply, automatic battery charger, 24 volts, 2 X 12 volts, 12 Ah sealed lead acid maintenance free batteries sufficient for 24 hours normal power backup & working, interconnections. The panel shall be UL listed & FM approved and shall be hookup with PA system and along with auto dialer facility etc. as required. (Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supply, Installation, Testing & Commissioning of UL / EN listed (latest version) Modular Microprocessor based expandable intellegent Addressable Type Fire Alarm Control Panel of following loops, with minimum 320 character graphics / LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM) ,The panel should be equiped with loop capacity to take minimum 240 intellegent addressable detectors/ devices (In any combination ) in one loop. Four access levels, capable of taking Protocol Devices, Graphical Display, sufficient numbers of programmable relay controls for controlling ventilation fan, fire pump room, monitoring of fire sprinkler and fire hydrant pump, 230 volts, 50 Hz AC power supply, automatic battery charger, 24 volts sealed maintenance free lead acid batteries sufficient for 2 hours normal working and then be capable of operating the system for 30 minutes during an emergency / fault conditions along with battery stand as required. The panel shall have facility for seamless integration with PA system (For Giving triger Signal to Start pre-recorded Digital Voice Evacuation from PA system in case of fire ). The panel shall be compatible for Building Management System with open protocol BACNET / MODBUS etc. as per specification, complete as required.(Approved Makes : APOLLO/ AUTRONOCA (UTC)/ EDWARDS (UTC)/ SIEMENS/ BOSCH/ NOTIFIRE/ SYSTEM SENSOR/ MORLEY IAS/ GROUP4/ MATHER & PLATT/ MINIMAX). , Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring &LSZH outer sheath complete as required.(Approved Makes : CMI/ KEI/ BONTON/ POLYCAB/BATRA HENLAY/ RR CABLE/ WAREXHAM). , Supply of 63mm dia., 15mtr. long RRL hose pipe (ISI Marked) with necessary male and female gun metal / SS couplings duly binded with GI wire, rivets etc. conforming to IS- 636 (Type-A) complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , Supply of standard short sized branch pipe constructed from SS material of 63mm dia.and be complete with male instantaneous spring lock type coupling for connection to the end of hose pipe,Externally threaded to receive nozzle,conforming to IS:903 etc. complete as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX). , supply of nozzle,20mm inner diamter,made of SS,screw threads at the inlet connection to match with the threading of 63mm dia branch pipe with inlet end of hexagonal head to facilitate screwing conforming to IS 903 etc. as required.(Approved Makes : FIRESHIELD/MINIMAX/NEWAGE/SAFEX).
Contract Date: Ref. Documents Contract Value : 13.35 Lakh
Boards / Undertakings / PSU No of Bidders 11
Daman and Diu View Result →
7.
Housing Urban and Rular Development #11294593 Technical Bid
Tender for (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). , Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Ns Item -Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (300 Sqmm Size). , Cloud Based Software Comprising Of Middleware, Database And Front-End Web Interface Through Suitable Dashboards, Aggregation Screens And Gis Assisted Drill-Down From Macro To Micro To Be Provided. Application Data Hosting And Maintenance For Five Years Included In Scope. Cloud Servicesof Ministry Of Electronics And Information Technology (Meity), Government Of India Empaneled Cloud Service Providers Shall Be Taken Like Microsoft, Amazon, Google, Bsnl Etc. Cloud Service Provider Must Adhere The Security Standards And Guidelines Issued By Meity From Time-To-Time. As The Data Belongs To The State Government Of Haryana, Therefore The Application And Data Hosted On Cloud Must Be Kept And Stored In Data Centres Located In India Only. Any Change In Application Requirement Or Infrastructure Shall Be Borne By The Implementation Agency. Implementation Agency Shall Carry Out The Application Security Audit From A Certified Auditor (Ca). Application And Data Shall Be Kept Confidential And Only The Authorized Users Shall Have The Access To It. Implementation Agency Shall Be Responsible For Any Data Theft Or Data Leakages. , Ns Item -Online Chlorine Sensor : Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Online Chlorine Sensor. (For Mbs) , Ns Item -Rtu: Functional Integration At Rtu-Cum-Gateway For Motorized Control Valve In Pump Control Panel (For Mbs) , Ns Item -Electromagnetic Flowmeter: Supply, Installation, Testing, Commissioning Five Year Maintenance, Electromagnetic Flowmeter Along With Its Installation Complete In All Respect As Per Specifications. Size As Per Site Requirement.(Ip-68), Rs-485 Modbus. Line Size 400 Mm, Installed At Pump End / Source. (For Mbs) , Ns Item -Automation Panel: Automation Panel For Integration With Vfd With Pump Control Panel, Along With Auto/Manual Selection Switch As Well As On/Off Push Button To Be Provided. Manual Selection Between Pump 1 And Pump 2 Depending On Which To Be Operated And Which To Be Stand By To Be Provided, Along With All Relay Interlocks And Provision Of Operation Of Pumps Through Potential Free/Open Collector Digital Outputs Of Rtu-Cum-Gateway Device. The Panel Will Contain Rtu-Cum-Gateway With Necessary I/Os And Edge Controller Motorized Control Valve In Local / Remote Or Auto/ Manual Modes Of Operation In Tandem With Cloud Scheduler Or Level Sensor-Based Functions. Panel Will Contain Smps With Rechargeable Battery Backup (Min. 24 Hrs.) Along With Facility To Connect All Field Instruments With 24 Vdc Power Supply. (For Mbs , Ns Item -Radar And Water Level Transmitter: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Radar And Water Level Transmitter Alongwith According To Water Level In Ohsr (For Ohsr) Ingress Protection - Ip 66, Measuring Range - Up To 20 M, Process Temp.- -40 To 60 Deg. C, Full Pvdf Body - For A Long Sensor Lifetime. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order. (For Mbs) , Ns Item -Sim Card: Sim Cards For Five Year Maintenance Of All The Instrument Above As Required. ( For Mbs) , Ns Item -Butterfly Valve: Supply, Installation, Testing, Commissioning With Five Year Maintenance Of Butterfly Valve With Electrical Actuator Body Material - Ci/Dipressure Rating - Pn16 Feedback - 100% Open And 100% Close. **Unit Rate Given, Actual Quantity To Be Ascertained While Placing Order 400 Mm , Ns Item - Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Finolex / Havells / repair renovation Cables. (35 Sqmm Size) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 160 Kva (As Per Parameters Of Cpcb 4) 160 Kva (As Per Parameters Of Cpcb 4) , Designing, Supply And Erection Of Dg Set Of Capacity Given Below With Noise Controlled Devices Acoustic Of Suitable Rating, Testing And Commissioning Of Diesel Generating Set, Radiator Cooled, 3 Phase, 4 Wire, 50 Cycles 415 Plus (-)1% Volts Ac Alternator Coupled Directly Through S Set Of Flexible Coupling On A Common Ms Fabricated Base Frame With Diesel Engine Complete With Suitable Size Incoming Cable From Generator To Change Over/Amf Panel, Making 2Nd Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Standers Panel, Making Second Incoming Cable Connection From Transformer, Outgoing Cable Connection From Changeover/ Std Panel To Incomer Of Motor Starter Panel, Fenced Enclosure With Platform For Dg Sets Complete As Per Following Detailed Scope And Specification And Directions Of Engineer-In-Charge. The Rating Should Be At 1500 Rpm. A) Diesel Engine B) Alternator C C) Battery 24 V. D) Base Plate. E) Suitable Sq Mm Suitable Core Copper Cable Upto 40 Meters. F) Tools, Standard Panel. G) Metering, Set 415 Vac-1 Set (Amp. Meter, Volt Meter, Ass, Vss, Phase Indicator, Control Fuse, Frequency Meter, CtS) H) Metering Set 60/5A//440V (Amp. Meter, Volt Meter). I) Overload Protection For Dc-1 No. J) Battery Charger 24V Dc K) Copper Bus Bar Of Suitable Size L) Kwh Meter 96 Sq Mm Size M) Starting Fuse Button And Key Switch9on/Off N) Indicating Lamps For Low Lubricated Oil Pressure, High Coolant Temperature, Set Running, Load On, Dc Control And Other Required Accessories Complete In All Respects To The Satisfaction Of Engineer-In-Charge 7. 200 Kva (As Per Parameters Of Cpcb 4) 200 Kva (As Per Parameters Of Cpcb 4) , Supplying, Erection, Testing And Commissioning Of Horizontal Centrifugal Clear Water Pumping Set Capacity 2780 Lpm X 50 M Head, 45 Bhp Motor, Complete With Installation At Mbs Near Yamuna River. , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 45 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs Near Yamuna River) , Design, Construction, Erection And Commissioning Of 2 No. Ranneywell 1 At Machhrola And 1 At Jajjal (Radial Collector Well) Of 10.00 Mld Capacity With Minimum Sinking Depth Of 32 Mtr And 1000 Mtr Long Laterals Pipe In 4 Layers, All Civil, Mechanical And Electrical Works Including Transformer As Per Design Along With All Accessories And Cables, Cubicai Type Lt/Ht Panels, Vcb Panels, All Types Of Cablings With Cable Tray, Chemical Earthings Of All Machineries, 4 Vt Pumps (3W Plus 1S) Having Capacity 180.00 M³/Hr. X 30 M Head, Vfd Panels, M.S Header With All Necessary Fittings, Gantry As Per Design, Electromagnetic Flow Meters At All Outlets And Inlets, Field Office (4 Mtr X 4 Mtr With Attach Toilet), Horticulture And Landscaping (3000 Sqm) Including Purchase Of 2.50 Acre Land (For Ranneywell, Mbs And Approach Path From Revenue Rasta To Well), Earth Filling In Ranneywell Complex. 1 High Mast Street Light 12.5 Mtr High Pole With 8 Luminous Lights, Wire / Cable, Switch. Mcb And Proper Foundation Etc Complete In All Respect. 10 Cp Plus Cctv Hd Coloured Night Vision Cameras And 1 360 Degree Dome Camera Fitted At 11 M. High Pole Along With Proper Foundation With Hd Night Vision. Plc/Scada Based Automation And Monitoring System. All The Pumping Machinery, Panel Board, Flow Meter, Level Sensor Etc Shall Be Controlled By Plc And Scada And Shall Be Synchronized With Plc Panels At Ranneywell And Mbs Site Through Broadband Internet Facility. The Work Will Be Carried Out Strictly As Per Detailed Scope Of Works, Specifications, Conditions Mentioned In The Dnit And Entire Satisfaction Of Engineer-In-Charge. (80 % Capital Cost Plus 20 % O/M Cost Payement Schedule Attached With Dnit.) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
8.
Defence #11281747 Technical Bid
Tender For Provision Of Defi Md Accommodation At Kota Mil Stn; 1 Lump sum price worked out by the contractor for BUILDING WORKSas listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 2 Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 3 Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 4 Lump sum price worked out by the contractor for ROAD, PATH, CULVERT AND HARD STANDINGas listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 5 Lump sum price worked out by the contractor for SEWAGE DISPOSALas listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 6 Lump sum price worked out by the contractor for AREA DRAINAGE as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 7 Lump sum price worked out by the contractor for FENCINGas listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceprepriced by the MES 8 Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLYas listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 9 Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATIONas listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 10 Lump sum price worked out by the contractor for LIGHTING PROTECTION as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 11 Lump sum price worked out by the contractor for FIRE FIGHTINGas listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 12 Lump sum price worked out by the contractor for LIFT WORKas listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 13 Lump sum price worked out by the contractor for HOT WATER SUPPLYas listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 14 Lump sum price worked out by the contractor for DG SETSas listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum priceof prepriced by the MES 15 Lump sum price worked out by the contractor for SITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORKas listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/belowthe lump sum price prepriced by the MES 16 Sch A Part-XVI MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes:(i) This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XVSITE CLEARANCE, SITE DEVELOPMENTAND EARTH WORK schedule). 17 INTERNAL WATER SUPPLYS&F for 15mm dia sink mixer (wall mounted) with 150mm long swivel spout,connecting legs and wall flangerswith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2014511 / Hindware Cat Part No F690058 / Parryware Cat Part No G3335A1 or equivalent make as mentioned in Appx B. 18 S&F for 15mm dia single lever center hole basin mixerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F1015451 / Hindware Cat Part No F690012 / Parryware Cat Part No G4863A1 or equivalent make as mentioned in Appx B. 19 S&F for 15mm dia wall mixture with bend pipe for overhead showerwith complete accessories etc complete all as specified and directed.Make: CERA Cat Part No F2002401 / Hindware Cat Part No F330020 / Parryware Cat Part No G3316A1 or equivalent make as mentioned in Appx B. 20 INTERNAL ELECTRIFICATIONS&F ofmodular type 3 pin 20 A socket with SP MCB, conforming to IS 1293: 2005as specified in IS 732: 2019 etc complete all as specified and directed 21 S&F for modular type 1 module RJ-11 telephone socket with shutter etc complete all as specified and directed 22 S&F for modular type 1 module co-axial type TV socket etc complete all as specified and directed 23 S & F for 16 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 24 S & F for 25 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 25 S & F for 32 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 26 S & F for 40 A, 230 V, 50 Hz, 2P MCB (B curve) MCB conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, bi-connect IP 20 protected lower terminals and sliding shutters,IS 732: 2019 etc complete all as specified and directed 27 S&F forSingle Phase Dual Source Pre Paid Meter, Class 1.0, RS485,10/60A Direct,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 28 S&F forThree Phase Dual Source Pre Paid Meter, Class 1.0, RS485, 5A CT operated,with followingspecification as under : (i) Communication options:, RS485 and RF(ii)Three in one option:Integrate gas & waterupto 4 DI(iii) Programmable tariff for EB, DG and DI for automatic reduction of balance even server is offline(iv) Configurable Holidays,Happy hours to avoidload switching on Holidays/Night(v) Alarm notifications for low credit balance(vi) Eliminate tenantdisputes, meter tampering & manualtariff reading errors 29 S&F of Sheet metal enclosure distribution board VTPN4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 30 S&F of Sheet metal enclosure distribution board VTPN6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed 31 S&F of 160A, 4 pole moulded case circuit breaker (MCCB) with thermal magnetic trip unit (TMD), compression lug connectors, protection against overloads (Ir adjustable from 0.7- 1 X In), protection against short circuits (Isd adjustable from 5- 10 X Ir), inbuilt encapsulated double break roto active type instanteneous protection, earth fault leakage protection, etc. having Ics = 100% = Icu = 16 kA as per IEC 60947-2 and suitable for 3-Phase, 415 V, 50 Hz electric supply etc complete all as specified and directed by engineer-in-charge. 32 S&F for 12W LED Downlight having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed . 33 S&F for LED light fitting with high 10 watt 220 V AC decorative wall type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size etc complete all as specified and directed . 34 S&F for 10W LED bulk head light having Luminous efficacy of > 100, input voltage range 140-270 V, input frequency 50-60 Hz etc complete all as specified and directed. 35 Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 600 mm sweep. Min air delivery 115 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) etc complete all as specified and directed by engineer-in-charge. 36 Supply and fix Wall Mounting Fan, steel body AC single Phase, 230V,With Sweep Size, 200mm ; Motor Speed 84CMM, 3 blades, and frame and louvers etc complete all as specified and directed by engineer-in-charge. 37 Supply, installation, testing and commissioning of factory made, indoor cubical compartmental type BUILDING PANEL (TTA) of suitable size for short circuit, temperature rise, protective earth short circuit test and dielectric tests of required ratings, conforming to IEC 61439-1 & 2 and IEC 61641, having both sides openable with hinged double doors and locking arrangement, IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel vitreous enameled (white) with letters, figures and conventional skull and bones in signal red colour suitable for 3- Phase, 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws, etc. complete as specified and directed by engineer-in-charge.The BUILDING PANEL shall comprise of the following:(A) Bus bar Chamber(i) 01 Set (3L + N) of copper busbar of rated capacity 400A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connections. 38 (B) Incoming:- (i)320A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, having microprocessor based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 01 No.(ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. Onhrs & interupts- 01 No.(iii) LED phase indicators (Red, Yellow, Blue)- 01 Set 39 (C) Outgoing:-(i)40A, 415 V, Ics = 100% Icu = 16 kA, 50 Hz 4P MCCB, conforming to IEC 60947-2, havingtrip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (ready, overload and pre-alarm & overload)- 08 Nos(ii) LED phase indicators (Red, Yellow, Blue)- 08 Sets 40 SEWAGE DISPOSALS&F for DWCPE (SN8) 180mm outer dia and 163 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8)with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 41 S&F for DWCPE (SN8) 200mm outer dia and 175 inner dia of pipe for depth 0.70mm to 1.65m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 42 S&F for DWCPE (SN8) 300mm outer dia and 260 inner dia of pipe for depth 1.65mm to 2.3m, laid on 150 mm thick bed (1:4:8) with excavation in any type of soil including manholes/drop manhole of standard sizemade of brick mosonary /RCC/Precast RCC with SFRC ventilating cover and frame,includes all items and activities to execute and make sewer line functionaletc complete all as specified and directed. 43 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-7 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 44 S&F forNonclog submersible (sewage disposal), pump set, electric driven 415 Volts 3 Phase 50 Hz, supply comprising of pump with cast iron impellors, submersible motor of suitable capacity, coupling, at discharge 3360 to 480 LPM and minimum discharge should be less than 480 LPM at minimum head 14 m.including chain pully block of two MT capacity 01 Noandsuitable arrangement for hanging the motor through chain of requirement of delivery of pump connected to main pipe line by suitabe HDPE pipe of size 150mm Dia for required length with necessary connection etc all as specified and as directed. 45 Supply,installing, testingand commissioningout door type LT feeder piller box of suitable size 750X750X450 mm, pedestal mounted, CPRI type test totally enclosed, dust and vermin proof, double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and paintedto both internal and External surfaces with powder coating paint in heatprocess of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and includingfollowing accessories and mounted on PCC Platform made out of100 mm thick PCC (1:3:6),0.45 Mtr all round the panel board etc complete with the following items :- 46 Incoming:- (i) Copper bus bar made up of copper strip100 amps duly mounted on bakelite insulatorssleevings of standard colour code - 01 Set. (04 No strips for Phases & Neutral)(ii) MCCB TPN 415 Volts,63 Amps, 50 Hz, breaking capacity 25 KA with fixed thermal & magnetic setting ( For Incomming ) - 01 No.Outgoing:-(i) MCB TP 415 volts 32 Amps, breaking capacity 16 KA with fixed thermal & magnetic setting ( For FPB2 ) - 03 Nos(2 nos for pump 1 nos for spare). (ii) FASD Starter for 15 HP Motor with single phase preventer, OLP and dry run protector- 02 Nos 47 (iii) Analogue type modular volt meterof range 0-500 volts -01 No(iv)Volt meter selector switch-01 No.(v) Analogue typeAmmeter of range 0-200 Amp-01 No(vi) Ammeter selector switch-01 No(set of three)(vii) Indicator lamp with integral circuit (230/240 volt) and cluster LED (Red, Orange, Blue) - 01 set(viii) CT 200/5 Amps - 3 Nos 48 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 49 S&F forPVC insulated and sheathed 1100 volts grade flat type submersible 06 sqmm cable three core multi stranded conductor etc complete all as specified and directed . 50 M&L for Making drill hole by trenchless technologyof suitable size under road for laying pipe line of size150mm bore at 1 metre depth from the road level etc complete all as specified and directed.Note :- Drill hole (trenchless) shall be done without disturbing top surfaces of road by appropriate machine. 51 M&L for steel gate 5.45 m wide and 2.70 m height with RCC pillar including excavation in any type of soil, plastering, painting, etc complete all as specified and shown in TD/2008/101 sheet No 1/3 to 3/3 52 EXTERNAL WATER SUPPLY Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 53 Supply, lay, commissioning, jointing and testing ofcentrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed.Note: The rate quoted by contractor are inclusive of all type of Joints. 54 Supply and FixingDI/CI special fittings of any size,type,radius angle,tapers increasing decreasing sockets,tees,tail piece and collars etc complete upto 200 mm dia etc complete all as specified and directed. 55 Supply and fix CI foot valve with leather washer, ofsize 100 mm , lift and swing, single door, IS 4038 marked one with each pump suction line complete all as specified and directed. 56 M&L for construction of valve chamber of brick masonry from the top of surface with MS covers 3.15 mm thick and 40x40x6 mm MS angle with hinges for locking arrangement including excavation and earth works PCC (1:3:6) type C2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1, plastering in CM 1:3 painting with two coats of synthetic enamel paint over a coat of red oxide primerfor the size of chamber 1200 mm x 1200 mm x 1200 mm (internal dimention) complete all as specified and directed. 57 Supply, install,commissioning and testing of Horizontal split case cetrifugal pump set 1450 RPM having an output of minimum 1100 LPM at a head of 45 mtr coupled to 3 phase 415 volt squirel case induction motor of adequate capacity complete all as ditected by Engr-in-charge with and including following :-(a) Necessary cable for interconnection between starter panel & pump set with 1100 volt rated copperinsulated unarmoured cable of minium 10 sqmm 3 core cable(b) Single phase preventer (current sensing type)(c) Necessary light grade GI pipe protection for cabling from pump set to LT panel.(d) Bourden pressure gauge.(e) MS pipe flanged type class B of size 100 mm bore upto foot valve from suction end of pump.(f) PCC foundation in type B-2, 1:2:4 using 20mm graded aggregate, 20cm above ground level and 30cm below grond level including grouting of eye bolts nut etc. for pump set of adequate size or as per manufacturers recommendations.Note: All other items/material requiredfor fixing pumpset shall be included in cost quoted.(ii) Foundation drawing shall be approved by GE/ Eng-In- Charge before fixing the pump set. 58 Supply, installations, testing and commissioning of factory made LT Indoor cubical typepanel boardhaving 150 Amp rated copper bus bar with neoprene rubber gasket and locking arrangement, dust,weather and verminproof , free standing, floor mounting type self ventilation with wire mesh,totally enclosed busbar chamber fully comparted type, front openable hinged independent door for each compartment with locking arrangement and common openable hinged door from rear side of suitable size made out of 2mm thick CRCA sheet duly painted with seven tank process,415 V,TPN,50Hz both side properly welded MS angular supported with chanel frame of size 50mm,at all vertical corner grouted in PCC 1:3:6 (Type-C1 using 20mm graded stone aggregate) and connecting the incomming/outgoing feeder by providing brass cable glands and Lugs complete all as specified and directed comprising of followings accessories:- 59 Incoming:- (i) MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than 36 KA (Ics=100 % of Icu) with adjustable thermal Setting-01 No.Outgoing:-(i)MCCB 3 Pole 63 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with adjustable thermal Setting - 02 Nos (ii) Single phase preventor -02 Nos(iii) On load Change over switch 4 pole of current raring 63 A (open execution type) - 01 No(iv)MCB SPN 10 Amp C curve, 10 KA capacity - 01 No(v) fully automatic Star-delta starter 15 HP or recommended by manufacturer of motor -02 Nos(vi) LED Indicator lamp (R,Y,B)- Set of Three.(vii) Multifunctional meterDigital type showing V,A,F,Pf,KW,KWH inbuilt selector switch with CT coiles for three phase -0 1No. 60 M&L for construction of header of ERW pipe having size dia 300 mm and length 2.5 m with two inlet connection of size 100 mm & three otlet connection having size 150 mm complete monting on RCC base/plinth etc complete all as specified and as directed by Engr-in-charge. 61 EXTERNAL ELECTRIFICATIONBoring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed.Note :- GI pipe shall be measured and paid separately. 62 Taking out existing HT XLPE U/G cables, 11000 V grade from trenches/ducts/ poles etc of size 120 Sq. mm 3 Core etccomplete all as specified and directed. 63 Dismantling and taking down existing transformer mounted on four pole structure and shifting to nearest suitable location including its fixing on newly constructed platform and making all connection, testing as per requirementetccomplete all as specified and directed. 64 Dismantling and taking down existing 4-pole structure etccomplete all as specified and directed. 65 Dismantling and taking down existing 03 Nos of LT Panels, refixing at specified locationincluding connecting etc complete all specified and directed. 66 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 240 Sq. mm 3.5 Core etc complete all as specified and directed. 67 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size 185 Sq. mm 3.5 Core etc complete all as specified and directed. 68 Taking out existing LT XLPE U/G cables, 1100 V grade from trenches/ducts/ poles etc of size upto 95 Sq. mm 3.5 Core etc complete all as specified and directed.Note For item No. 57 to 63 :- The old material obtained from site shall be deposite by contractor in MES store yard without any extra cost as directed by GE. 69 M&L for construction of plateform of size 3500 x 3500 x 1200mm with brick construction in cement mortar 1:4 PCC (M-10 nominal mix) in foundation, 100mm thick RCC M-25 grade slab, with 8mm MS TMT bars 120mm c/c on bothway, brick masonary steps on one side XPM Jali fixed on angle iron 40x 40x6 mm post upto height of 8 feet above ground level and openable gate with locking arrangment including making provision for entry and exit of HT/LT cables and steps made to access to the top of plateform including plastering to bricks masonary complete including painting with 2 coats of whitewash on plastered surface and painting steel surface with 2 coats of red oxide primeretc complete all as specified and directed. 70 Supply & fix HT 11 KV, outdoor type gang operated air-break switch suitable for horizontal or vertical mounting rotating type complee with drop out fuse having 12 insulators of rating upto 200 Amps etc complete all as specified and directed. 71 Supply and fixing lightning arrestor HT 11 KV, 10 KA station class etc complete all as specified and directed. 72 Supply & errect 2 pole structure on 11 mtr PCC pole consisting of pole with anti-climbing device, PCC foundation & cross arms (Bracings) etc for one incoming and one out going. etc complete all as specified and directed. 73 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station (CSS) ,315KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply .Package substation will have the following equipment :- 74 HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos 75 (vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 SetTRANSFORMER315 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 955W and Max Losses @ 100% Load 2750 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be conforming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 500 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)500 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB)(ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 76 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robust. 77 construction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 78 Supply, installation, testing & commissioning of package type/unitised 11kV / 433 V Outdoor sub-station , (CSS) 400KVA made from G. I. enclosure complete as required conforming to IEC 62271-202 only and relevant IS specifications including K-10 Temperature Class as applicable for the rating, Internal Arc of 21 KA/1 Sec. IAC AB on 1:2:4 (1 cement :2 cores and : 4 Graded stone aggrregate of 40 mm nominal size) PCC foundation of suitable size extending 500 mm all around the outdoor enclosure and 1000 mm height (above ground level) complete with suitable sizes of GI Pipes for incoming/outgoing cables/earthing strips etc. and consisting of following complete as required. Angle iron frame of size 40x40x5mm NS all along the corner of the foundation CSS shall be from OEMs only . Licensed System Integrators of approved OEM are not allowed to supply.Package substation will have the following equipment :-HT SWITCHGEAR11kV 630Amps 21KA/3 sec. Non-Extensible Ring Main Unit Compact switchgear consisting of1 no. fixed motorized Vacuum Circuit Breaker Moduleand 2 nos. fixed morotized Load break switch module in SF6 insulated stainless steel enclosure with series trip, self powered microprocessor based numerical over current and earth fault relay protection. HT RMU shall preferably have site replaceable bushings to have very less downtime in the event of bushing breakage and restoration can be done immediately without sending the 79 RMU to OEM Works. Interconnection between HT Switchgear and primary of transformer shall be done through 1C x 3R x 95 sq.mm Aluminium XLPE cable. - 1 No.Vacuum Interrupter,RMU,LT Switchgear and CSS Enciosure shall be of same make to ensure life cycle optimization.(i)Microprocessor based IDMT Relay for Circuit Breakers - Self Powered along with series trip coil (Modbus RS485 complaint)(ii)Capacitive voltage indication fixed type system with LED for all feeder and FPI in all load break switch feeder.(iii)SF6 Gas pressure indicator.(iv)Operating sequence of VCB must be O-0.3Sec-CO-3 Mins-CO(v)Protection CT shall be minimum 40/1A ,2.5VA ,5P10. - 3 Nos.(vi)All modules of the RMU shall be suitable for cable termination of 3C x 300 sq.mm Al XLPE Cable, incoming cable termination is included within the scope of work - 1 Set 80 TRANSFORMER400 KVA 11KV/433V DYN-11 Oil type, hermetically sealed energy efficiency level-2 transformer (BEE Star Rated-2) with corrugated wall, without conservator, type of design & Top Bushings for HT & LT with Off load tap switch of rating +5% to -5% @2.5%. Temp Rise - Oil/Winding 40/45 Deg cel. Losses (As per IS-1180 amended up to date)Max Losses @ 50% Load 1150W and Max Losses @ 100% Load 3330 KW and Impedance of 4.5% (Subject to IS Tolerance (as per IS1180-2014) The transformer shall be confirming to IS: 2026 and IS: 1180(part-I). amended up to date. (i)01 No. Winding Temperature Indicator with Alarm and trip Contact.LT PANELLVS PANEL 630 AMPS 4 pole Aluminium BUSBAR (100% FOR PHASES AND 100% FOR NEUTRAL) - CURRENT DENSITY OF Aluminum as 1 A/sq.mm. ; LT panel made up of 1.5/2 mm thick CRCA sheet INCOMER CUM OUTGOINGS FROM TRANSFORMER(i)630 Amps 433V 4P 50Hz 50KA Fixed Manual Type Air Circuit Breaker (ACB) (ii) Multifunction meter with Modbus RS485 port & class 0.5 accuracy with Suitable CT. - 1 set 81 (iii)Hard wiring from each equipment inside CSS for scada connectivity (monitoring & control)to be brought to one set of TBs and a space for FRTU to be given. Supply of FRTU is not in scope. (iv)All Civil works such as PCC/RCC foundation, Plateform, Filling trench and pedestal etc as per CSS manufacturers recomandation are included in scope of work.OUTDOOR ENCLOSUREOutdoor type encloser of 1.5 mm (For non load bearing members) & 2.0 mm (For load bearing members) thickness having modular construction of Galvanised Sheet Steel in suitable design for better heat dissipation and providing robustconstruction. The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP 23 degree of protection for transformer compartment. The enclosure exterior shall be painted with epoxy based powder paint (colour RAL 7032). Each compartment will be provided with the door and pad locking arrangement. The design of the enclosure should be type tested for suitablly handling any arcing inside the compartment for providing better safety to the operator. The compartment illumination lamp with door operated switch shall be provided for each compartment.Vacuum Interrupter,RMU,LT Switchgear, Multifunction meterand CSS Enciosure shall be of same make to ensure life cycle optimization. 82 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge(Panel 1 - Near mains transformer GTC Area):- 83 INCOMING :-(i) S&F ACB 4 Pole 630 amps ,415 Volt electrical drawout type of breaking capacity not less than50 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 750 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBsOUTGOING:-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of block )(ii) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(ivDigital volt meter 0-400 V with selector switch - 01 No.(v)LED Indicating Lamps R,Y,B - 01 Set of three 84 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2 - Near Chambal Vihar Main Tfr Panel):-INCOMING :-(a) S&F MCCB 4 Pole 500 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(b) Aluminium electrolite Busbar 600 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 85 OUTGOING:-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 No (for LT distribution panels of blocks)(ii) S&F MCCB 4 Pole 160 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0) -02 Nos(for LTP Pump Motor, lift, fire fighting, stree light etc + spare).(iii)Street light timer using Power contactor 32 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(iv)Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(v)Digital volt meter 0-400 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 86 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1A - LT PANEL FOR 3 X BLOCKS GTC):-INCOMING :-(i) S&F MCCB 4 Pole 315 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 87 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 04 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 88 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 2A - LT PANEL FOR 2 X BLOCKS CHAMBAL VIHAR):-INCOMING :-(i) S&F MCCB 4 Pole 250 amps ,415 Volt of breaking capacity not less than36 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 01 Nos Incommer.(ii) Aluminium electrolite Busbar 400 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs 89 OUTGOING:-(i) S&F MCCB 4 Pole 125 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range (Optium 2.0) - 03 No (for 3 X Blocks+spare)(ii) Digital Ammeter 0-500 A with selector switch & CTs of suitable capacity - 01 set.(iii)Digital volt meter 0-400 V with selector switch - 01 No.(iv)LED Indicating Lamps R,Y,B - 01 Set of three 90 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel 1B & 2B):-INCOMING :-(i) S&F MCCB 4 Pole 200 amps ,415 Volt of breaking capacity not less than25 KA (Ics=100 % of Icu) with Adjustable TM Range-01 No incoming.(ii) Aluminium Electrolite Busbar 300Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 91 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series. - 01 Nos (for PH Panel)(ii) MCCB 4 pole 40 Amp, 415 V, 16 KA, C-series- 02 Nos (sewage PH +spare).(iii) MCB TPN 25Amp, 230 V, 10 KA, C-series - 07 Nos (Lifts+fire fighting+Street lights)(iv)Street light timer using Power contactor 25 Amps, (1-NO) 3 pole, 415Volt, DIN Type digital programable time switch 230V AC, Auto/Manual selector switch, MCB 4 pole 25 Amps C-range, ON/OFF indicator all prewired and making provision for fixing outgoing cables- 01 Set complete.(v) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(vi) Digital volt meter 0-500 V with selector switch - 01 No. (vii) On load Change over switch 4 pole of current raring 63-100 A (open execution type) - 01 No.(viii)LED Indicating Lamps R,Y,B - 01 Set of three 92 Supply, installations, testing and commissioning factory made out door cubical typeLT panel board dust and verminproof , free standing, floor mounting type mounted on and incluidng1:3:6 PCC foundation as requried at site and of fabricated by 3.0mm thick CRCA Sheet over MS 50 X 50 x 6 mm thick angle iron frameof requriedtype for support with double door both sides open type with necessarylockingarrangement with sloppedroof on top duly paintedwith two coatsof powder coated semense gray paint complete and having separatedoors inside for accomodatingall incomming / outgoing feeders of suitable sizes all as specified and directedby Engr-in- Charge:- (Panel D - DOE Area):-INCOMING :-(i) S&F MCCB 4 Pole 100 amps ,415 Volt of breaking capacity not less than16 KA (Ics=100 % of Icu) with adjustable thermal Setting (Optium 2.0)-01 No incoming.(ii) Aluminium Electrolite Busbar 150 Amps current rating duly sleev insulated for set of 3 phase, 4 wire system and branch connection of suitable size of outgoing current rating of MCB/MCCBs-01Set 93 OUTGOING:-(i) MCCB 4 pole 63 Amp, 415 V, 16 KA, C-series - 02 Nos (for Bldg + Spare)(ii) MCB SPN 10 Amp, 415 V, 10 KA, C-series - 02 Nos (Garages + Spare).(iii) MCB SPN 10 Amp, 230 V, 10 KA, C-series - 02 Nos (Security light + Spare)(iv) Digital Ammeter 0-150 A with selector switch & CTs of suitable capacity - 01 set.(v) Digital volt meter 0-500 V with selector switch - 01 No.(vi)LED Indicating Lamps R,Y,B - 01 Set of three 94 M&L for factory made busbar box 750 Amps rated Aluminium busbar, 3 phase, 4 wire, 415 Volt of size not less than 300mm x 200mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wal by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 95 M&L for factory made busbar box 600 Amps rated Aluminium busbar, 1 phase, 245 Volt, size not less than 200mm x 150mm x 100mm, fabricated using 1.6mm MS sheet, duly painted with smoke gray powder coated over a coat of red oxide primer suitable for fixing on wall by using wall fastners 10mm dia and making necessary incomming and outgoing connection of electric cables using aluminium lugs etc complete all as specified and diected. 96 Supply and fixing poly carbonatejunction box , weather and vermin proof of size 250X250X160 including provn of 4 Nos aluminium strip 25x3.15 mm size bus bar single phase and neutral suitabely mounted on bus bar insulators ,including one No. MCB SP 6 Amps for light control,drilling of holes.Provn of suitable size of GI nuts, bolts, double washer and FI clamps ofsuitable sizefor taking connections and fixing on LT steel tubular poles complete with locking arrangementcomplete all as specified and directed. 97 Supply and connecting three core cord flexible wire, copper conductor multistranded, PVC insulated and overall PVC sheathed of size 1.5Sqmm 1100 Volt , draw through LT steel tubular polesfor connection to street light from junction boxetc complete all as specified & directed. 98 S&F for Cable route indicator, duly engraved with LT CABLE 1100 VOLT on cast iron round plate 150 mm dia with provision of 500 mm long (minimum) single leg/stand of flat iron 40 x 5 mm, welded/riveted on back side of plate, fixed and grouted in position with PCC 1:3:6 type C-1, block of suitable size etc complete all as specified & directed. 99 M&L for Precast PCC (1:2:4) type B-1 cable path indicators of size 300x100x500mm rounded top having engraved in capital letters HT Cable embedded in position in PCC(1:3:6) Type C-1, using necessary formwork and including provision of two coats of cement base paint on exposed concrete surface and writing HT Cable in black synthetic enamel paint etc complete all as specified & directed. 100 M&L fordecorative LED post top lantern (PTL) luminior with die cast aluminium spigot, spun aluminium powder coated top cover clear/opal acralic difusser LED light fitting of 25 watts including LED lamp etc complete all as specified & directed. 101 M& L for shifting of 33 KV HT cable to a safe distance from proposed building, supply, laying, testing & commisioning of 33 KV cable in replacement with new as per estimate provided by State electricity deptetc etc complete all as specified & directed. 102 FIRE FIGHTINGS&F forAutomatic air release valve 50mm dia suitable for domestic water with 25mm gun metal stop valveetc complete all as specified & directed. 103 S&F forbranch pipe with nozzle of 20mm dia for hose reel conforming to IS 8090etc complete all as specified and directed. 104 S&F forfix Valve, stop, screwed, 25 mmdia pipeetc complete all as specified and directed. 105 S&F for6 kg capacity Multipurpose dry chemical powder (ABC) type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/charged .etc complete all as specified and directed. 106 S&F forCO2 type fire extinguisher of 3 Kgs capacity with steel cylinder with a discharge valve and confirming to IS : 15683.Extinguisher shall be painted with red enamel apint and fixed to wall with bracket etc complete all as specified and directed. 107 S&F for9 Ltr capacity Foam type(IS-15683) fire extinguishers consisting of welded MS cylindrical body fabricated from 1.6 mm MS sheet internally protected with anticorrosive treatment and hydraucally tested. Extinguisher externally painted with red enamel and fixed to wall with bracket complete with initial filled/chargedetc complete all as specified and directed. 108 S&F fortesting of Star-Delta starter Panel for fire fighting pump motor etc complete all as specified and directed. 109 Supply, installation, testing & commissioning ofFIRE SIGNAGES for indication/information of fire exit, alarm panel, fire extinguishers fire axe, hose reel, hydrents, lifts of size 300mmx100mm etc complete all as specified and directed. 110 DG SETSSupply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 180 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 111 (A) Engine (prime mover) : Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. 112 (C) Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate.(D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1No 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications.(F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - 113 (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running (iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- 114 AC voltmeter - 01NoVoltmeter selector switch OFF/RY/YB/BR - 01NoFrequency meter - 01NoAC voltmeter of suitable scale - 01NoAmmeter selector switch OFF/R/Y/B - 01NoCurrent transformers of suitable ratio - 01NoBattery charger consisting of - 01No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01NoMains supply voltage monitor - 01NoSet of DC control relays and timers - 01NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01No 115 01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 116 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 117 Supply, installation, commissioning and testing complete of Manufacturer of OEM (Original Eqpt Manufacturer) manufactured and tested static Diesel Engine driven generating set capable of delivering 125 KVA continuous rating, (10% overload for 1 hour in 12 hours of operation), 415 volts (AC 3 phase, 4 wire system of supply), 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching alternator, and mounted on Dunlop metallastik foundation pads on a common base frame and thereafter installed in the CPCB approved acoustic enclosure complete with control panel standardised by manufacturer, fuel tank with mounting arrangement and inlet, outlet, return oil arrangement, flexible exhaust pipe complete all as specified and directed and shall include comprise of the following :- 118 (A) Diesel engine 1500 RPM, of suitable HP as recommended by manufacturer, water cooled, turbocharged, 12 volts electric battery start, complete with fly wheel and torsional vibration damper, rediator and all standard fittings/fixtures as per standard manufacturing practices and including suitable instrument panel with RPM meter, lub oil temp and pressure gauge, water temp gauge and frequency meter (digital type), battery charging ammeter and fuses, and also including self starter (12V), battery charging alternator, fuel tank etc and complete with HWT and LLOP alarm and shut down safeties complete with first fill of Lub oil and Coolent. (B) Alternator : AC alternator, brushless, 415V AC 50 Hz, 3 phase, 4 wire type, rated for continuous output of 63 KVA, PF 0.8 (lag), 1500 RPM insulation class H; enclosure SPDP (IP 22/23), self excited & self regulated with AVR for + 1% voltage regulation, coupled directly/suitably to and to match the above engine and conforming to BS 5000/IS 4722. (C)Dunlop Metallastik anti-vibration of pads for mounting engine - alternator assembly on the base frame/plate. 119 (D) Base plate : Made out of structural steel as per manufacturers recommended design/specifications.(E) Enclosure : Provision of an integral type, approved/certified acoustic enclosure as per latest CPCB norms, for the DG set to restrict the noise level to 75 DB (A) at one metre and ensure that temperature rise within the canopy shall not exceed 5 - 7 degree celsius, It shall be made of 16 SWG CRCA MS sheet with powder-coated finish on outside and high quality noise absorbent and fire retardant grade acuoustic insulation material duly provided with EPDN gasket lining. There shall be four hinged doors out of which one shall be with a glass window.(i)Silencer : Absorption type, non-resistance, residential.(ii) Internal wiring with PVC copper conductor cables, IS 694 marked, FRLS in conduit and suitable light fittings.(iii)Fuel tank to be provided as per OEM specificaton.(iv)Safeties for high enclosure temperature and emergency shut-down from outside.(v) 1Nos 12V of suitable AH lead acid batteries and adequate size copper conductor cable leads, housed on & including suitable size MS angle iron frame and necessary clamps, nuts, bolts, washers all as required & as per manufacturer design/specifications. 120 (F) Control panel : Control panel made out of 14 gauge CRCA sheet, powder coated and shall consists of the following: - (i) Ps 0500 Controller (ii) Aluminium Bus bars with suitable capacity incoming & outgoing terminals.(iii) Indicating lamps for load on and set running(iv) Instrument fuses duly wired and ferruled. (v) Circuit breaker(MCCB) of suitable rating with overload and short circuit protections. Note: To be mounted inside enclosure. (G) Automatic mains failure (AMF) control panel fabricated from CRCA sheet steel of thickness not less than 3.15 mm, suitable for outdoor installation (including CPRI type test certified), dust & vermin proof, protection class I P-54 suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply system with adequate layers of power coating floor mounting type with front opening, the AMF panel shall comprise the following indicating instruments & switches:- AC voltmeter -01 NoVoltmeter selector switch OFF/RY/YB/BR - 01 No 121 Frequency meter - 01 NoAC voltmeter of suitable scale - 01 NoAmmeter selector switch OFF/R/Y/B - 01 NoCurrent transformers of suitable ratio - 01 NoBattery charger consisting of - 01 No(aa) Transformer / Rectifier unit (bb) DC ammeter /DC voltmeter(cc) Charging rate selector switch OFF/Trickle/BoostMains supply air break contactor, 3 pole of suitable raing - 01 NoAlternator air break contactor, 3 pole of suitable rating and provided with a separate overload relay for overload protection - 01 NoMains supply voltage monitor - 01 NoSet of DC control relays and timers - 01 NoSet of push buttons, START, STOP, ACKNOWLEDGE, RESET, MAINS BREAKER, CLOSE/TRIP, ALTERNATOR BREAKER CLOSE / TRIP - 01 No01 Set of indicating lamps for the following :-LOAD ON MAINS, LOAD ON SET, SET FAILS TO START, LOW OIL PRESSURE, HIGH TEMPERATURE ALARM, HIGH TEMPERATURE TRIP, ALTERNATOR OVERLOAD.Audio - alarm hooter - 01NoKWH meter - One Set of Bus bars - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections. 122 KW meter - 01Noset of bus bar - 01NoThe control cubical will be furnished complete with the necessary control circuit fuse etc and will have provision for making incoming and outgoing connectionsOne - set of bus bar - 01NoThe control cubicle will be furnished complete with the necessary control circuit fuses, etc. and will have provisions for making incoming and outgoing connections.Note :(i) In case AMF panel included instead of Standard Control Panel, then Battery charging alternator with inbuilt regulator and battery charging ammeter should be deleted from engine specifications since Battery charger included under AMF Panel specifications. 123 (ii) Platform : PCC foundation /plinth/baseshall be provided as per drawing No: TD/2010/109, Sheet No 1/1.(iii) Tool kit, Operation and Maintenance catalogue, 1 year spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. 124 Supply, installations, testing of electric chimney of size 60cm havingsuction capacity of 1200 cum per hour with filterless technology sealed motor and insulationfor oil deposit and water vapour alongwith self autoclean feature after 30 cycles of operation and minimum 5 year warranty etc etc complete all as specified and directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
9.
Public Administrative Department #11258632 AOC
Tender For Providing And Fixing Of Spares For Ht, Lt, Apfc, Starters, Other Panels And Repairing Of Various Equipment And Electrical Installation For Gangapur Dam Pumping Station, Booster Pumping And Various Tp Of Nmc.-1 P/F digital ammeter for measuring current 2 P/F digital voltmeter for measuring voltage 3 P/F multifunction meter 4 P/F selector switches for voltmeter & ammeter 5 P/F light emitting diode type indicator 6 P/F switch disconnector fuse (SDF) a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 7 P/F moulded case circuit breaker (MCCB) a Up to 100A. b 200A. c 250A. d 315/400A. e 600 / 630A. f 800A. 8 P/F MCB a 6A to 32A b 40A to 63A. c P/F One way distribution board suitable for MCB 9 P/F Busbar chamber with triple pole neutral aluminium bus bar a 100A. b 200A. c 300A. d 400A. e 630A. f 800A. 10 P/F DOL starter a Up to 7.5HP. b Up to 10HP. 11 P/F street light bracket complete 12 P/F FRP box on pole/wall complete a 150mm x 125mm x 100mm, 2.7 mm thick b 250mm x 200mm x100 mm, 2.7 mm thick c 300mm x 200mm x125 mm, 2.7 mm thick 13 P/F LED 22W tube light fitting (4 feet) with aluminium housing, heat sink, integrated HF electronic driver complete 14 Providing and filling Transformer oil 15 Point wiring in PVC trunking (casing-capping) with (2+1E) copper wire, modular type switch, earthing and required accessories 16 Point wiring for independent plug in PVC trunking (casing capping) with (2+1E )FRLSH grade copper wire, modular type switch, earthing and required accessories 17 P/F mains with 2 X 2.5sq.mm 1.1KV grade copper PVC stranded/solid wire complete (2 core, 71+36(1 core earthing)=107/- ) 18 Supplying and erecting PVC trunking (PVC casingn- capping) of size 25mm with accessories on wall/ceiling 19 P/F half round 15cm dia RCC hume pipe with necessary back filling etc complete 20 Providing and spreading stone metal 25mm size for 100mm depth above the ground level. 21 P/F three phase heavy duty power capacitors in suitable banks with voltage rating 440V, 50Hz 22 Providing and laying Aluminium conductor 3.5 core XLPE/PVC armoured 1.1KV grade cable a 25sq.mm b 35sq.mm c 50sq.mm d 70sq.mm e 95sq.mm f 120sq.mm g 150sq.mm h 185sq.mm i 240sq.mm j 300sq.mm k 400sq.mm 23 Providing and laying Aluminium conductor 1 core XLPE/PVC armoured 1.1KV grade cable a 1 Core, 630sq.mm b 1 Core, 800sq.mm c 1 Core, 1000sq.mm 24 Providing and laying Aluminium conductor 4 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm d 16sq.mm 25 Providing and laying Aluminium conductor 2 core XLPE/PVC armoured 1.1KV grade cable a 4sq.mm b 6sq.mm c 10sq.mm 26 Providing and laying copper conductor 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable a 2 Core, 2.5sq.mm b 3 Core, 2.5sq.mm 27 P/L flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 28 Providing and laying Alu. conductor 3 core, XLPE /PVC 3.3KV armoured cable a 70sq.mm b 95sq.mm c 120sq.mm d 150sq.mm e 185sq.mm f 240sq.mm g 300sq.mm h 400sq.mm 29 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 30 P/F Heat shrinkable indoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 31 P/F Heat shrinkable straight through joint kit for 3 core, 3.3Kv (E) XLPE HT cable etc complete a 70-120sq.mm b 150-185sq.mm c 240-400sq.mm 32 Providing and laying Aluminium conductor 3 core, XLPE/PVC 11KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 33 P/F heat shrinkable outdoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 34 P/F Heat shrinkable indoor termination kit for 11Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a 70-95sq.mm b 120-185sq.mm c 240-300sq.mm d 400sq.mm 35 P/F Heat shrinkable straight through joint kit for 3 core, 11Kv (E) XLPE HT cable etc complete a 70-95sq.mm b 120-185sq.mm c 240-400sq.mm 36 Providing and laying Alu. conductor 3 core, XLPE / PVC 33KV armoured cable a 95sq.mm b 120sq.mm c 150sq.mm d 185sq.mm e 240sq.mm f 300sq.mm 37 P/F heat shrinkable outdoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 38 P/F Heat shrinkable indoor termination kit for 33Kv (E) XLPE HT cable erected and connected to the supply with insulated sleeves,additional lugs & nut bolts for all core for 3 core cable with HT testing at site etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 39 P/F Heat shrinkable straight through joint kit for 3 core, 33Kv (E) XLPE HT cable etc complete a up to 70sq.mm b 95-150sq.mm c 185-240sq.mm d 300-400sq.mm 40 P/F Heat shrinkable straight through joint kit for flexible PVC sheathed submersible type copper cable. a 4 core 2.5 sq mm b 4 core 4 sq mm c 4 core 6 sq mm d 4 core 10 sq mm e 4 core 16 sq mm f 4 core 25 sq mm g 4 core 35 sq mm 41 P/F HT capacitor suitable for 3.3KV in suitable banking 42 Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete 43 Powder coating in siemens gray colour 44 Making Iron work for fabrication with bending, cutting, drilling and welding complete 45 Epoxy painting on both side of approved colour shade of provided iron work 46 P/F GI strip of suitable size 47 P/F M.S. stand for fire bucket 48 P/F Wall hook for fire bucket 49 P/F G.I fire bucket 9Lit 50 P/F Instruction chart 51 Pair of rubber hand gloves 52 Supplying and erecting fire extenguisher 4.5Kg 53 P/F High voltage insulating Electromat confirming to IS 15652 :2006 a Suitable for 3.3KV. b Suitable for 11KV. c Suitable for 33KV. 54 Providing and laying double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete a 50 mm b 75 mm c 90 mm d 120 mm e 160 mm f 175 mm g 200 mm 55 P/F Flood light LED fitting for street light a 50W b 70W c 100W d 120W e 155W f 195W 56 P/F aluminium PVC unarmoured cable 2 X 6sq.mm of 1.1kv grade 57 P/F mini feeder pillar triple pole with 200A MCCB as incomer etc complete 58 P/F mini feeder pillar triple pole with 300A MCCB as incomer etc complete 59 P/F fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work complete 60 P/F double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire meshcomplete 61 P/F 50 x 50 x 6mm angle iron corner support 0.5m away from fence support fixed etc. 62 Providing and fixing ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps 63 P/F analog Ammeter for measuring current 64 P/F analog Voltmeter for measuring voltage 65 Providing and laying XLPE armroured cable for 3.3KV with ISI mark 1 core 630 sq.mm. stranded aluminium wire in an approved manner. 66 P/F heat shrinkable outdoor termination kit for 3.3Kv (E) XLPE HT cable erected and connected the supply with insulated sleeves,additional lugs nut bolts for 1 x 630 sqmm cable with HT testing site etc complete 67 P/F programmable logic controller for Thyristor logic KPOPF – 406 – T. 68 P/F Injector module for Thyristor logic KPIPF 406 – T. 69 P/F Zero switching module for Thyristor logic KPZPF – 406 – T. 70 P/F current generator 440V, 50Hz, for final compensation of real time PFC after basic compensastion using programmable logic controller, relay module, ZCS control thyristor units with its software, hardware, power and control cabling etc complete. a Up to 42A b 42A to 56A c 70A to 105A. d 112A to 140A 71 P/F ROM-51 memory controller with accessories along with routine software program for Thyristor logic. 72 P/F ROM-51 memory controller with accessories along with routine software program for zero switching logic. 73 P/F voltage transformer with 11V, 18-0-18V, 22V, 8V secondary. 74 P/F output module for soft starter-KPOSS-306. 75 P/F proportional Integral card with operational amplifier KPISS-306. 76 P/F analog to Digital converter ATD-09. 77 P/F MCR-31 Main controller with accessories. 78 P/F 7-Segment common anode display controller DSP-79 with accessories. 79 P/F RAM-64 memory unit with accessories. 80 P/F ROM-SS-64 memory unit with accessories along with routine software program. 81 P/F ROM-SS-51 memory unit with accessories along with routine software program 82 P/F flat band cable set 26pin. 83 P/F flat band cable set 20pin. 84 P/F glass type relay O/E/N RL-24. 85 P/F 2A fuse box of EI for power supply (20Nos). 86 P/F 2A glass fuse base open type FBO. 87 P/F tertiary current transformer 88 P/F PLA relay 24D 1NO RDRL-24. 89 P/F SMPS ripple filter choke 5V DC, 1500mA. 90 P/F 24VDC, 10A Electromechanical relay PLA and snubber. 91 P/F voltage transformer with O/P 6.8V, 11.5V, 22.5V Delta to star. 92 P/F programmable logic controller module for contactor logic KPOPF – 406 – C. 93 P/F injector module for contactor logic KPIPF – 406 – C. 94 P/F relay module for contactor logic KPRLPF – 406 – C. 95 P/F ROM-51 memory controller with accessories along with routine software program for contactor logic. 96 P/F thyristor back to back connected suitable for following starters and Capacitor banks. a 75HP. b 120HP. c 215HP. d 300HP. e 10KVAR f 15KVAR g 20KVAR h 25KVAR i 30KVAR 97 P/F inductor suitable for following Capacitor banks. a 10KVAR b 15KVAR c 20KVAR d 25KVAR e 50KVAR 98 P/F electrical contactors. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 99 P/F main contact kit for power contactor. a 32A. b 40A. c 70A. d 110A. e 200A. f 300A. g 400A. h 650A 100 P/F HRC fuses. a 40A. b 50A. c 63A. d 100A. e 125A. f 160A. g 200A. h 250A. i 315A. j 400A. k 630A. l 800A. 101 P/F fuse bridges. a Up to 32A. b 63A. c 160A. d 250A. e 800A. 102 P/F change over switches. a 63A. b 125A. c 200A. d 250A. e 315A. f 400A. g 630A. h 800A. i 1000A. 103 P/F timers. a ET-100. b Star-Delta. 104 P/F FASD starter. a ML2 b ML3 c ML4 105 P/F energy efficient street light fitting using 36W CFL lamps complete. 106 P/F 11KV HT fusegear for fuse switch unit of CGLucy 107 Actuator control unit. a P/F forward / reverse contactor b P/F over load relay. c P/F contact kit 108 Providing and laying copper conductor 12 core 2.5sq.mm XLPE/PVC armoured 1.1KV grade cable 109 P/F electronic control unit suitable for up to 175HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 110 P/F electronic control unit suitable for up to 300HP, control Supply 240V AC, Power Suply 415V AC, with all test and trials complete. 111 P/F limit Switch for gate 112 P/F 10 Turns Preset. 113 P/F panel accessories such as push button with indicators, NO/NC contact, emergency stop push button, copper lug for control cable, gasket, etc complete. 114 P/F C I pipe type earthing etc complete. 115 P/F 230V, 2 C/O panel mounted relay. 116 P/F single phasing preventer relay 117 P/F single phase, under voltage, over voltage protection relay. 118 P/F oil temperature sensing relay 119 P/F winding protection relay 120 P/F reverse rotation sensing relay 121 P/F Motor protection relay for LT motor 122 P/F Control transformer with protection circuit 123 P/F PVC type earthing chambers with accessories for earthing. 124 Power contactor coil LC-1F 330 125 P/F sequence controller 126 Providing, fixing termination box for submersible pump to ATS starter with bus bar, terminations etc complete 127 Providing and laying 95sq.mm copper conductor 1 core flexible PVC unarmoured 1.1KV grade cable 128 Energy meter panel a P/F Energy meter single phase 230V, 50Hz, 10A supply complete b P/F Energy meter 3 Phase, 4 wire, 50Hz, 100A supply complete c P/F L.T. Current transformer of suitable ratio d Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete e Powder coating in siemens gray colour f Control wiring using copper wire, ferrule, lugs, tie saddle, spiral etc complete. g Panel accessories such as hardware, gasket, insulator, panel knob, panel lock for each feeder complete . h Dismantling of old meter panel by disconnecting connections of all cables, etc complete i Installation of new meter panel by fixing meter box, making incoming and out going connection etc complete. 129 Starter Panel a P/F digital ammeter for measuring current b P/F digital voltmeter for measuring voltage c P/F selector switches for voltmeter & ammeter d P/F light emitting diode type indicator e P/F L.T. Current transformer of suitable ratio f Providing and fixing Main Incommer 63A moulded case circuit breaker g P/F 100A Busbar chamber with triple pole neutral aluminium bus bar h Making fabrication work using 16 gauge metal sheet with bending, cutting, drilling and welding complete i Making Iron work for fabrication with bending, cutting, drilling and welding complete j Powder coating in siemens gray colour k P/F DOL ML 1.5 starter l P/F FASD ML2 starter m P/F FASD ML3 starter n P/F FASD ML4 starter o P/F Over load relay. p Control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. q Local/remote wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete. r Panel accessories such as hardware, gasket, insulator, panel knob, panel lock, bus bar terminals, etc complete. s Dismantling of old starter panel by disconnecting connections of all cables, etc completet Installation of new starter panel by fixing starter panel, making incoming and out going connection etc complete. u Terminations main outgoing cables by using lugs glands etc complete. 130 LT Panel, Changeover Panel, Distrubution Panel, Feeder Panel a Power wiring up to 63A feeder using copper wire, lugs, tie saddle, spiral etc complete. b Control wiring for metering using copper wire, ferrule, lugs, tie saddle, spiral etc complete. c Panel accessories such as hardware, gasket, insulator, backlite, panel knob, panel lock, push button with indicators, heavy duty connectors earthing arrangement, etc complete for following feeders i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A d Dismantling, disconnecting connections of all cables, shifting old panel in godown etc complete of following capacity. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A e Installation of panel at desired place including loading unloading and transportation of following capacity i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A f Making new terminations of main incoming/outgoing cables, etc complete for following feeders. i Up to 100A ii 100A to 250A iii 250A to 400A iv 400A to 800A g Interlocking, forward/reverse, timing and control circuit/star delta circuit etc control wiring using copper wire, ferrule, lugs, tie saddle, spiral, etc complete for one feeder. 131 P/F 3 phase street light timer controller of 60 A per phase rating with in-built relay, timer, protections, display 132 Providing, fixing and testing of HT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 133 Providing, fixing and testing of LT TOD meter of appropriate class with required accessories along with co ordnation with MSEDCL complete. 134 P/F Motor protection circuit breaker 135 P/F 3 Phase heavy duty industrial socket. 136 P/F 1 Phase heavy duty industrial socket. 137 P/F and erecting 6mm Polycarbonate multiwall ultravoilet protected sheet for roofing over fabricated steel structure as per detail design, including fixing the Polycarbonate sheet with alluminium angle & Flat anodized & dyed as per approved shade including all water proofing materials, nuts bolts hardware, labour & square pipe, angles, fabrication complete including all hardware etc. as required . (only actual area of polycarborted sheet to be considered for measurements) 138 Making isolation circuit using AB switch / D.O. Set for single pole & converting the cutpoint by dismantling with nessasary material, jumping, earthing along with arrangement of shutdown etc. complete. 139 P/F diesel filling pump for filling diesel in dg sets from store tanks etc complete. 140 P/F meter box for single phase energy meter complete. 141 P/F meter box for three phase energy meter with compartment for mccb/mcb etc complete. 142 P/F of spares for DG control panel a Flush mounted panel meter three phase four wire for frequency etc. b 12V/80AH Battery c 12V/100AH Battery d 12V/150AH Battery e 12 V/180AH Battery f 12V/200AH Battery g Battery water h EPU unit i AVR j AMF Controller k Voltmeter DC l Ammeter DC m Push button n ESR D1 o 12V battery charger p 24V battery charger q Overload relay r Relay s Electronic Timer t Hooter u Connector 143 Reconditioning of transformer a Inspection of distribution transformer on HV and LV side b Dismantling the distribution Transformer from the plinth / foundation c Providing and filling Transformer oil d Painting of transformer using smoke gray paint complete e Providing and rewinding of copper material for HT coils f Heating of core and winding, including removing of moisture etc complete g Providing oil arresting sheet for low tension side of R Y B studs, 5mm thick properly fitted in the studs of transformer. h Providing oil arresting sheet for top cover of oil chamber, LT connection box, oil tank etc parts ,5mm thick properly fitted in the top cover and nut bolts of transformer i Providing R Y B stud bushings over the oil arresting sheet on the studs of transformer . j Reinsulation by high quality uniform covering throughout of 11KV windings using accessories complete k Reinsulation by high quality uniform covering throughout of 415V windings using accessories complete l Repairing and servicing of tap changer of transformer m Transformer oil filtration n Changing silica jel of breather and adding breather oil. o Loading, unloading and transportation of transformer. p Attendance, engineering charges for connection of HT/LT cables and giving satisfactory test & trials of transformer complete 144 P/F Analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to 20 mA/13 bits), standard 145 P/F Analog input module AI 4xI, 2wire- MU(4..20mA), standard 146 P/F Digital output module DO 8xDC24V/0.5A, supports isochrone mode 147 P/F Power module PM-E for electronic modules, 24 VDC, with diagnostics 148 P/F Digital input module DI 8xDC24V, supports isochrone mode 149 P/F IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 150 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 151 P/F Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 152 P/F Programmable logic controller 1769 TW Digital input module 32 point. 153 P/F Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 154 P/F Programmable logic controller 1769 Digital output module 32 point. 155 P/F Programmable logic controller 1769 Power unit. 156 P/F Programmable logic controller 1769 Compact I/O to DSl module. 157 P/F Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 158 P/F Programmable logic controller 1969 Endcap right. 159 P/F Laser printer Spares for VCB 160 P/F closing coil assembly- 4VC49-110 161 P/F tripping coil assembly- 4VC49-106 162 P/F micro switch 163 P/F breaker auxiliary switch 164 P/F spring charging motor 165 P/F closing shaft with spring. 166 P/F tripping shaft with spring. 167 P/F charging handle assembly 168 P/F pinion gear assembly 169 P/F spur gear assembly 170 P/F bridge rectifier 171 P/F spring for tripping catch 172 P/F tripping catch assembly 173 P/F closing catch assembly 174 P/F driving rod assembly 175 P/F nut assembly 176 P/F cam shaft assembly 177 P/F vacuum interrupter Spares for VC 178 P/F closing coil assembly for VC 179 P/F tripping coil assembly for VC 180 P/F 2 Pole auxiliary switch 181 P/F micro switch 182 P/F bridge rectifier 183 P/F vacuum interrupter 184 P/F contact shroud assembly 185 P/F PDS assembly- 4VC19-0027/01 186 P/F shutter assembly- 3VB79-310/04 187 P/F 5 pole auxiliary switch- J309-022 HT Panel Spares 188 P/F moulded contact shrouds- 1VB79-0009/04 189 P/F shutter assembly- 3VB79-0087/02 190 P/F push button- green button with spring. 191 P/F push button- red button with spring. 192 P/F PDS assembly- with fixing nut bolt- 4VC19- 0027/03 193 P/F insulated stud assembly 194 P/F flexible jumper with fixing bolt- 3VC19-0009 195 P/F coupling 196 P/F bus conductor- upper- 4VC13-0002 197 P/F bus conductor- lower 198 P/F top cover for U barrier- 4VC19-0117/01 199 P/F 16 Pin plug with socket- 4VC46-0303 200 P/F PT fuse 201 P/F voltage transformer (PT) of suitable Ratio secondary 110VAC and suitable class: 202 P/F current transformer (CT) of suitable ratio secodary 5A and suitable class. 203 P/F TNC switch 204 P/F local remote switch 205 P/F PVC shroud- CT/PT/CR surg 206 P/F PVC shroud- 630A 207 P/F contact shroud for PT. 208 P/F rubber gasket for door 209 P/F bushing plate- VCB 210 P/F control fuse with assembly, 440V 211 P/F loose vacuum contactor [Electrically held] type JVE1-604. 212 P/F loose vacuum Contactor for soft starter MVC400D, 400Amp, 3.3KV, 2P, Control supply 220VDC, Solenoid type, with 3 economy resistance- CVC0004, 213 P/F electronic timer suitable in HT starter. 214 P/F Over current, Earth fault relay and short circuit protection relay and retrofitting if required. 215 P/F Under voltage/ Over voltage protection relay and retrofitting if required. 216 P/F Master trip relay and retrofitting if required. 217 P/F Trip circuit supervision relay and retrofitting required. 218 P/F auxillary relay for contact multification RE-300 Aux supply: 110V AC / DC 219 P/F auxiliary contactor for vaccum contactor operation 110VDC with resistor complete. 220 P/F limit switch for service & test position 2 Pole. 221 P/F tripping relay VAJH 3NO + 1NC, 110VDC 222 P/F selector switch for HT panel 223 P/F breaker operated switch 10 pole, 5NO + 5NC. 224 P/F power pack unit Input: 110V AC, Output: 110VDC 225 P/F On line UPS pure sine wave with standard features a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 226 P/F SMF battery a 12 V/17Ah -18Ah b 12 V/26Ah c 12 V/42Ah d 12 V/65Ah e 12 V/100Ah 227 P/F fixed resistor 1000 ohms. 228 P/F safety switch for VC HRC fuse P/F blow pole 1C/O 229 P/F connecting rods for safety switch 230 P/F safety switch for VC trunk Interlock 2 Pole NO + 1NC.231 P/F high voltage 3.6KV HBC fuse links for short circuit protection. 232 P/F and giving satisfactory test and trials of 3.3 KV 104Kvar Capacitor panel as per rate analysis. 233 P/F and giving satisfactory test and trials of 3.3 KV 208Kvar Capacitor panel as per rate analysis. 234 P/F MM30 type protection relay Machining and fabrication works for couplling of actuator and valve 235 P/F Universal joint 236 P/F Mounting bracket 237 P/F Flange 238 P/F Coupler 239 P/F Shaft coupler 240 P/F Additional shaft 241 P/F Fastener bolt, hardware, etc accessories 242 P/F 0.6mm GI sheet 243 P/F regular/ standard model Ceiling fan complete 244 P/F ISI mark modular type (two module) electronic step regulator for fan 245 P/F condenser 2.5 micro farad for ceiling fan 246 P/F anchor type fastener fan hook, with 2 nos. of 10 mm dia x 75 mm long with necessary materials for ceiling fan. 247 P/F fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted. 248 P/F fan hook of 10 mm. M.S. round bar grouted in RCC slab 249 P/F ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire 250 P/F heavy duty exhaust Fan 251 Refilling of fire extinguisher of by dismantling from site to workshop for refilling which includes removing of existing powder and cleaning the cylinder, delivery pipe , nozzle internally and refilling new powder complete with reinstalling properly at site 252 Dismantalling old rusted perforated type cable tray.253 P/F hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 100 mm width with necessary coupler plates and hardware in approved manner etc complete. 254 P/F, testing and commissioning split type variable speed Inverter technology room Air conditioning unit 1.5 TR capacity suitable to operate on 250V, 50 cycles, A.C.supply having 1 no of air handling unit hiwall / floor mounting type complete. 255 P/F, testing and commissioning split type variable speed inverter technology room Air conditioning unit 2 TR capacity suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete 256 P/Laying PVC insulated PVC round sheathed 2.5 sq.mm 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 257 P/F copper pipe suitable for refrigeration system having size 12.7 mm complete. 258 P/F bracket for split type AC 259 P/F copper pipe suitable for refrigeration system having size 15.9 mm complete. 260 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 12 mm 261 P/F Elastomeric Nitrile rubber / foam tube type sleeves for over coating and insulating on provided copper pipes having sizes 16 mm 262 P/F rigid PVC pipe 20 mm dia.with PVC accessories for drain 263 Carrying out core cutting of size 3 to 5 dia x 15 length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original. 264 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 265 Providing, Installation, Testing and commissioning of borewell type maintenance free chemical earthing comprising of Electrode of 80 mm diameter rod of Length 1.5m along with 15 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. 266 Providing and making platform by making excavation for foundation, situ cement concrete of M-10, uncoursed rubble masonry of trap, rubble stone soling 15cm to 20dc thick including hand packing and compacting, situ cement concrete of M20 grade trap, steel bar rainforcement of various diameters for RCC work, sand faced plaster externally in cement mortar, etc complete 267 Providing hand drill Machine 268 Providing hand grinder 269 Providing Crimping tool up to 400sq.mm 270 Providing Insulator tester ( Megger ) cranking type having metal body of range 100 Volts 1000 Ohms 271 Providing fix spanner set 12 piece set 6 -32 mm 272 Providing Bi-hexagon Ring spanner 12 piece set 6 - 32 mm 273 Providing screw driver a Screw driver Engineering pattern 6 X 300 mm b Screw driver Engineering pattern 8 X 200 mm c Screw driver Engineering pattern 5 X 200 mm d Screw driver Engineering pattern 5 X 300 mm e Screw driver with green neon bulb line tester 3.6 X 60 mm 274 Providing Multimeter 275 Providing Tong Tester ( Clip on meter ) of range 0- 10-30-100-1000 Amps and 0-300-600 Volts 276 Providing Ball pen hammer with handle 800 gm 277 Providing Hack saw frame 300 mm size with heavy duty blade 278 Providing blower 279 Providing single phase welding machine 280 P/F fixing isolator suitable for 33KV capacity 281 Providing office regular with handle chair 282 Providing fabricated powder coated rack 283 Providing computer table 284 Providing 18 compartment steel clothes locker with powder coating, locking arrangement, etc complete. 285 Providing regular office wooden table 286 Providing wooden chair 287 Providing and fixing Openable Steel Storage of 750 x 450 x 2100Ht, with 4 adjustable shelves, Complete body & shutter made in 0.8mm thick & Top in 2mm thick CRCA, Shutter to be mounted with the help of cuphinges, and adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns 288 Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish 289 Providing & Arrangemnt of High Back chair, Synchronized Mechanism with Multiple Locking, Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery 290 P/F disc type insulator suitable for 33 KV line complete erected with suitable Hardware on provided cross arms as per IS. 291 P/F pin type insulator suitable for 33 KV line, complete erected with suitable hardware on provided cross arms. 292 P/F G.I. stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm., straining screws, G.I. stay wire 7/8 SWG, G.I. stay rod 20 mm x 1.8 meter length and pole clamps duly erected in provided cement concrete foundation. 293 Providing and fixing Nut bolts and Sundries etc accessories 294 Making isolation circuit for all 3 phases and interlocking the same to provide 33KV output from 2 Nos of 33KV input feeders using accessories etc complete. 295 Dismantling the existing old 33KV circuits and all jumps, accessories, etc complete. 296 Providing and fixing safe shade ESE type lighting arrestor system complete with following details. a P/F safe shade ESE type lighting arrestor as per NFC17-102 (2011) UNE 211862011 standards, CPRI tested, area covered 107 Mtr, etc complete. b P/F GI mast 5mtr long wth base plate complete c P/F 6 Digit counter, etc complete d P/F accessories for lightning arrestor, etc complete. e P/F test link box etc complete. f Providing, laying and terminating single core 35sq.mm copper flexible cable for earthing 297 Providing and making overhead cablling works for clarifier bridge slipring a P/F slipring b Providing and laying copper conductor 1.5sq.mm X 4 core XLPE/PVC 1.1KV grade cable c P/F hardware, bobbin, anchor fastners, cork sheet etc accessories for slipring fixing works. d P/F GI wire of high purity of different sizes used for earthing. e P/F attachment to slipring for entering cable from top using GI pipes, coupling, flange, bend, by machining and threading the components so that cable will remain fix when clarifier is rotating. f Making arrangement using provided GI wire, bobbins to carry the provided cable overhead from filter to clarifier. g Making terminations for slipring main panel, clarifier panel, etc.Part B- Annual maintenance contract 1 Servicing and overhauling of APFC panels. A Servicing of APFC panel by making terminations of power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, tightening all connections, changing hardware, insulator, gasket, replacing provided blown fuses, fuse base, indicators and other parts as required in engineering manner for each bank complete as follows. a Control feeder for 1 to 5KVAR bank. b Control feeder for 5 to 10KVAR bank. c Control feeder for 10 to 20KVAR bank. d Control feeder for 20 to 30KVAR bank. e Control feeder for 30 to 50KVAR bank. B Servicing of main programmable logic controller injector module, ZCS module, by correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, tightening all connections, adjusting preset values to maintain unity power factor, checking transformer voltages, current ratios, checking of panel & cleaning of panel complete. 2 Servicing and overhauling of soft starters. Servicing of contactor by changing provided contact kits, coil, terminations, control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches, servicing of analog card, digital card, display card, correcting dry solder, calibrations of three phase voltage, currents, all parameters, power supplies, adjusting preset values, checking transformer voltages, current ratios, termination of incoming outgoing cables as required. Also tightening of connections, cleaning of panel complete. a 70 to 90HP. b 90 to 120HP. c 120 to 150HP. d 150 to 215HP. e 215 to 300HP. f 300 to 1000HP 3 Servicing and overhauling of starters. Servicing of contactor by changing provided contact kits, coil, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches checking oil level and top up, auto transformer links, termination of incoming outgoing cables as required. Also tightening of connections, setting of timers and cleaning of panel complete. a 3 to 7.5HP. b 7.5 to 12.5HP. c 12.5 to 20HP. d 20 to 30HP. e 30 to 50HP. f 50 to 70HP. g 70 to 90HP. h 90 to 120HP. i 120 to 150HP. j 150 to 215HP. k 215 to 300HP. 4 Servicing and overhauling of distribution panels. Servicing ,repairing of distribution panels by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections of feeders of following capacity. a Up to 32A b 32A to 63A c 63A to 100A d 100A to 150A e 150A to 200A f 200A to 250A g 250A to 400A h 400A to 630A i 630A to 800A j 800A to 1000A k 1000A to 1250A l 1250A to 1600A 5 OCB to MCCB conversion. Dismantling output starter’s cable terminated to OCB, dismantling incoming and outgoing bus bar of OCB to main LT panel, dismantling OCB from main LT panel properly. Making iron frame for fitting of MCCB. Fitting of MCCB in main LT panel with proper hardware, covering the front open portion with 16SWG MS sheet with adjusting slot for MCCB handle. Terminating the R Y B connection of MCCB with main LT panel’s bus bar using appropriate rating of copper flexible cable and proper copper lugs. Reconnect the output’s starter cable to MCCB, taping all power connections, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Replacing indicators and other parts as required. Cleaning of panel, tightening of all connections. 6 Servicing and overhauling of actuator electrical control module. Servicing of actuator electrical control module by servicing of contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 7 Callibrating all presets/sensor for gate/screen with open/close and electronic indication system. Checking control wiring for remote and local operation, adjusting limit switches with proper close and open, giving satisfactory test and trials of remote and local system etc complete. 8 Servicing and overhauling of alum mixer control module. Servicing of alum mixer module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 9 Servicing and overhauling of chlorine plant control module. Servicing of chlorine plant module by servicing of SFU, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 10 Servicing and overhauling of clarifier control module. Servicing of clarifier module by servicing of breaker, servicing contactor by changing provided contact kits, coil, checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Replacing blown fuses, fuse base, indicators and other parts as required. Cleaning of panel, tightening of all connections. 11 Servicing and overhauling of HT substation. a Servicing and overhauling of 4 pole structure, servicing air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, servicing and overhauling of D.O. set by polishing hansa and punja, applying jelly to all hansa and punja, changing fuse link tightening of connections, changing hardware, changing ACSR jumper links by properly lugging and binding using alkathene pipe. HT taping of connections, checking of insulators, insulation test of total installation and earth test of earthing pits. b Cleaning of substation area, painting of 4 pole structure , fencing and gate using aluminium paint and scraping old paint. Painting of transformers using AD gray paint and scraping old paint. 12 Servicing and overhauling of 33KV H.T. Substation at Gangapur Dam pumping station. a Servicing of air break switch by polishing contacts, applying jelly to contacts, alignment of AB switch, tightening connections, changing hardware, etc complete. b Painting of gantry structure for air break switch by cleaning all poles channels using aluminium paint 3 coats. c Servicing of D.O. set by polishing hansa and punja, applying jelly to hansa and punja, tightening connection, changing hardware and fuse wire, etc complete. d Painting of gantry structure for D.O set by cleaning all poles channels using aluminium paint 3 coats. e Servicing of PT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring voltages at out put for main bus, bus-1 and bus-2. f Painting of gantry structure for main bus PT by cleaning all poles channels using aluminium paint 3 coats. g Painting of gantry structure for PT bus-1 and bus-2 by cleaning all poles channels using aluminium paint 3 coats. h Painting of PT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. i Servicing of VCB by checking operating mechanism, alignment, applying jelly to various parts, control wiring, remote local operation, spring charging, insulation tests for main bus, bus-1 and bus-2. j Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. k Servicing of CT by checking, lugging, tightening HT and earthing connections, checking, tightening secondary connections, measuring currents at out put for main bus, bus-1, bus-2. l Painting of gantry structure for VCB and CT for main bus, bus-1 and bus2 by cleaning all poles channels using aluminium paint 3 coats. m Painting of VCB for main bus, bus-1 and bus-2 by cleaning them and using smoke gray paint 3 coats. n Painting of CT for main bus, bus-1, bus-2 and MSEDCL by cleaning them and using smoke gray paint 3 coats. o Painting of gantry structure for MSEDCL CTPT structure by cleaning all poles channels using aluminium paint 3 coats. p Painting of gantry structure for cut point by cleaning all poles channels using aluminium paint 3 coats. 16 Repairing of analog input module AI 2xI, 4-wire transmitter (+/-20 mA /13 bits+sign, 4 mA to mA/13 bits), standard 17 Repairing of analog input module AI 4xI, 2wire- MU(4..20mA), standard 18 Repairing of digital output module DO 8xDC24V/0.5A, supports isochrone mode 19 Repairing of power module PM-E for electronic modules, 24 VDC, with diagnostics 20 Repairing of digital input module DI 8xDC24V, supports isochrone mode 21 Repairing of IM151-8PN/DP central processing unit work memory 192KB; 0.06ms/1000 instructions; PROFINET connection; S7 communication (loadable FBs/FCs); PROFINET IO-Controller; supports RT/IRT; PROFINET interface and 3 ports; MRP; PROFINET CBA; PROFINET CBA-Proxy; transport protocol TCP/IP, 22 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus master log with 8 byte I/O interface 23 Repairing of Communication module with a serial interface (RS232, RS422 or RS485) and Modbus slave log with 8 byte I/O interface 24 Repairing of Programmable logic controller 1769 TW Digital input module 32 point. 25 Repairing of Programmable logic controller 1769 Analog input module 8C 0-10V 0-20 26 Repairing of Programmable logic controller 1769 Digital output module 32 point. 27 Repairing of Programmable logic controller 1769 Power unit. 28 Repairing of Programmable logic controller 1769 Compact I/O to DSl module. 29 Repairing of Programmable logic controller 1769CMPAC Logix processor ethernet 2MB 30 Repairing of Programmable logic controller 1969 Endcap right. 31 Inhouse Programmable logic controller software devlopment charges. 32 On site commissioning of hardware, testing the complete system, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 33 Servicing and overhauling of programmable logic controller panels complete system. Servicing ,repairing of programmable logic controller panels by checking software routine, debugging software, analysing the ladder diagrams, checking hardware and relay module, terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of control cables as required. Cleaning of panel, tightening of all connections, etc complete. 34 Repairing, servicing of electromagnetic flow meter a P/F main kit PCB b P/F single card c Panel weather proof including internal wiring and components d Service charges e Setting and callibration of flow meter 35 Reparing of On line UPS pure sine wave by dismanteling, trasportation and reinstalling after repairing complete. a 1KVA b 2KVA c 3KVA d 6KVA e 10KVA 36 Servicing of DG control panel by servicing of EPU unit, battery charger, setting of timer, making control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware procured from material list like voltmeter, ammeter, selector switches, connector, MCB, indicators, push buttons. Also tightening of connections and cleaning of panel complete. 37 Servicing and overhauling of battery charger panel Servicing and overhaulling of battery charger panel by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, provided indicators, voltmeter, ammeter, selector switches termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections, cleaning of battery terminals, checking battery voltages, battery cable lugs, etc complete 38 Servicing of RO/UV/UF water purifier by changing/cleaning of carbon filter, pre filter, sedement filter candles, cleaning of water purifier etc complete. 39 Repairing in point wiring wiring for light fan instrument with ISI mark 2-1sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 40 Repairing in power point wiring with ISI mark 2-1.5 sq.mm, copper wire PVC insulated 1.1KV grade with necessary accessories as required complete. 41 Repairing of board with necessary accessories as required complete. 42 Installation of transformer with loading, unloading, transportation 43 Carrying out necessary tests before and after charging transformer upto full load to satisfaction by connecting earthing, incomming and outgoing cables etc complete. 44 Providing minor repairs to existing plumbing system. 45 Providing major repairs to existing plumbing system. 46 Tracing out fault in cable/cable kit/cubical, removing the connection of cable, taking insulation test. After fixing new cable/cable kit, making termination of the cable again taking insulation test and giving satisfactory test and trials, etc complete. 47 Dismantalling temporary hangging wires accessories, etc complete. 48 Chiselling of wall for laying cable / mains, clamping it properly and refilling the broken wall by using POP etc complete. 49 Repairing, servicing of synchronization panel by servicing of contactor by changing provided contact kits, coil, servicing of electronic controller, control relays terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, push buttons, voltmeter, ammeter, selector switches, termination of incoming outgoing cables as required. Also tightening of connections and cleaning of panel complete. 50 Annual Maintenance Contract for Power Genset includes routine check-up visits with following scope of work and all breakdown visits including spares and major repairs throughout the year. A 82.5KVA Gangapur Dam Pumping Station B 140KVA Shivaji Nagar WTP. C 250KVA Dwarka Pumping Station D 250KVA Gopalnagar Pumping Station E 400KVA Chehedi Pumping Station F 400KVA Nasikroad WTP. G 400KVA Gandhinagar WTP. H 400KVA Nilgiribag WTP. I 600KVA Panchavati WTP Scope of worka B check kit (oil filter set, fuel filter set) shall be changed as required. b Engine oil 15W40 suitable for genset shall be changed as required. c Air cleaner element shall be changed as required. d Coolant shall be filled and top up as required. e Checking temperature, removing leakages, checking battery voltage, battery charging voltage, output voltage, frequency, AVR, tappet setting for good performance of genset. f Routine checkup visits should be done monthly. g Apart from above scope of work all major works to be carried out including all spares of generator excluding panel, batteries as and when required through out the year except total engine failure, natural disaster like flood etc. 51 Transformer oil filtration 52 Making trench in soft soil for laying provided cable 53 Breaking bituminous/ concreate road by JCB/Tractor breaker complete. 54 Providing and casting in situ cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal, moulded or chamfered as per drawing or as directed for coping to plinth or parapet, including centering, form work, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, roughening them if special finish is to be provided and curing and finishing if required etc. complete. (The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Wooden planks / shuttering will not be allowed) 55 Providing and laying jointless a highly flexible elastometric coating for RCC / cementitious surface for terrace waterproofing on B.B. Coba / R.C.C, on perfectly clean surface (free from loose dust and foreign matter) application of 1st coat of Polydee- LM @ 700 gms/Square Metre and applying 2nd coat of Polydee-LM @ 700 gms/Square Metre and finishing complete. 56 Repairing, servicing of crane panel by servicing forward/reverse contactor. Checking control wiring, adjusting limit switches, giving satisfactory test and trials of control systems etc complete. 57 Dismantling, disconnecting connections of all cables of ATS starters as fer following details. a Up to 80 HP. b 80HP to 200HP c 200HP to 300HP. 58 Erection of ATS starter panel at desired place including loading unloading and transportation and grouting it properly, etc complete as fer following details a Up to 200 HP. b 200HP to 300HP. 59 Annual Electrical inspection, compliance, test reports of earthing, insulation test etc complete for substation. 60 Annual Maintenance Contract for surge arrestor includes routine checkup visits with following scope of work and all breakdown visits including all spares and major repairs throughout the year etc complete. a Checking of surge arrestor pnumatic system by checking valve, pressure gauge, level gauge, solenoid valve, servicing of surge arrestor tank component, giving test and trials of automatic functioning of magnetic level sensors, checking all pressure etc complete. b Checking of compressor piston ring, gasket, shaft, filter, oil seal, oil ring, discharge valve, inlet valve, oil filling/top up and giving satisfactory test & trials of compressor. i Compressor No-1 ii Compressor No-2 c Checking of control panel for surge arrestor unit by checking terminations, power and control wiring, lugs, tie, saddle, ferrules, bus bars, hardware insulator, gasket, indicators, voltmeter, ammeter, selector switches. Cleaning of panel, tightening of all connections etc complete. 61 Repairing servicing of VCB/VC by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking auxiliary contacts, closing coils, terminal strips, VCB/VC operation, insulation tests and giving satisfactory test and trial complete. 62 Repairing servicing of control feeder panel for VCB/VC by checking terminations, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, bus bars, changing hardware insulator, gasket, indicators, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete. 63 Repairing servicing and attending breakdown of CG Lucy unit by checking operating mechanism, alignment of contacts, applying jelly to various parts, tightening all connections, polishing contacts, checking fuses, top up oil level, oil BDV test, CG Lucy operation, insulation tests and giving satisfactory test and trial complete. 64 Servicing of OLTC by checking operating mechanism, alignment, applying jelly to various parts, checking of control panel operations and replacement of provided indicators, switches, control fuses, hardware, insulator, gasket, polishing contacts, power and control wiring using appropriate wire, lugs, tie, saddle, ferrules, termination of incoming outgoing cables as required. Cleaning of panel, tightening of all connections etc complete.
Contract Date: Jun 10, 2026 Contract Value : 94.40 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
11.
Railways #11184865 AOC
Supply Of supply, installation, commissioning and testing of variable speed drive. , supply, installation, commissioning and testing of variable speed drive.,number of phase :3 phase,supply frequency:50...60 hz +/- 5%{us} rated supply voltage:380...480 v-15..10 % norminal output current-12.7 a,motor power kw-7.5 kw for normal duty, 5.5kw for heavy duty,motor power hp-10hp for norm al duty,7hp for heavy duty,emc filter-class c3 emc filter integrated,physical interface :2-wire rs 485, conn ector type-3 rj45,brake chopper integrated-true,ip degree of protection-ip20, mounting mode-cabinet mou nt,variant-standard version,communication port protocol-ethernet/ip, mdbus tcp, modbus serial network a nd similar in all respects with altivar machine atv340, model-atv340u55n4e with basic operator panel (bo p) display model-vw3a1113, display type-backlit lcd screen white plain text display terminal,altivar,pixel resolution-128 x 64, ip degree of protection -ip21,operating temperature is 50 deg. c, .required make: -schneider electric,allen bradley,siemens and abb or equivalent. note:-the offered drive shall be dimensio nally compatible with the existing control panel and shall fit without any modification. overall dimensions s hall not exceed those of the currently fitted drive {height {h}-295 mm, depth(d)-234 mm,width (w)-175 mm}, and no additional enclosure or extension shall be permitted and fitment shall be the sole responsibili ty of the supplier without any extra cost. [ warranty period: 30 months after the date of delivery ] ]
Contract Date: May 29, 2026 Contract Value : 1.60 Lakh
Government Departments No of Bidders 1
12.
Drinking Water Supply and Sanitation #11129348 Technical Bid
Tender for Ht Metering Panel: Supply Indoor Type 11Kv Vcb Control Cubical Panel With Vertical Isolation Type Breaker As Per Relevant Is As Amended Up To Date And Additional Specifications, Having Capacities As Mentioned Below, Single Break Trip Free Mechanism, Manually Charged And Auto/Manually Closing Breaker Suitable For Use On 11Kv, 3 Phase 50Hz Ac, Supply With Short Circuit Fault Level Of 500 Amps Capacity, Breaker Featured With Local On/Off Indicator With Hand Trip Device, Spring Release Coil, Shunt Trip Coil And Auxiliary Switch Of 2No Plus 2Nc And Equipped With Following Switchgears And Accessories Including Making Suitable Structure Arrangement For Installation, Control Wiring And Connections Etc. As Reqd. (1 Ic Plus 2 Og) A). Vcb, 11Kv, 630Amp, 50Ka. B). 1Ph 11Kv/110 Volts Pt (Indoor Type) Class 0.2 Accuracy And 100 Va Burden -3 NoS. C). 33Kv Indoor Dead Type Dual Core Dual Ratio 3Cts Of Ratio 200-100/5-5 A Of 15 Va Burden, Ps 5 P10 And Accuracy Class 0.2. D). Control Panel- Cubicle Type Control Panel Suitable For Floor Mounting Made Out Of 1.63 Mm Cr Sheet Duly Powder Coated And With Following Relays. E). Microprocessor Based Numerical Relay For O/L, E/F And Sc Protection Suitable For Above. F). Master Trip Relay -2 NoS. G). Indicator Type Annunciator Panel With Buzzer. H). Digital Volt Meter- 0-11 Kv. I). Digital annual periodical maintenance Meter- 0-100 Amp. J). Ryb/ Trip/Closing/Spring Charged Indicator Lamp. K). Fault Annunciator Panel For O/L, Wti, Oti And Buchhloz Relay Alarm And Trip Auxiliary Relay. L). Tnc Switch For Operation. M). Multifunction Meter Em6400ng. N). Tcs Relay For Safe , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (50 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (70 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (95 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (120 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (150 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make:Finolex / Havells / repair renovation Cables. (185 Sqmm Size) , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 250 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 400 Mm Nominal Diameter , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 400 Mm Nominal Diameter , Supply Erection Testing Of Reputed Make Led Light 100 Wats With Fittings And Accessories Complete In All Repects. , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 350 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 350 Mm Nominal Diameter , Providing, Fixing, Jointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Ns Item -Providing And Fixing Of Ci Sluice Valves Conform To Is 14846 / Din 3352, With Length Over Flanges As Per Pd Or Alt 1 Of Is 14846 Corresponding To Bs En - 558 / Iso 5752 Basic Series 3 And 15 Respectively Including Labour, Material, Joints. Make: Ivc / Vag / Kirloskar Complete In All Respect As Per Specifications Mentioned In Dnit 800 Mm I/D , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 13200 Lpm X 20 Mtr. Head (For Mps Idgah Road) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 8800 Lpm X 20 Mtr. Head (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 100 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 65 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 35 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Mps Idgah Road) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 4000 Lpm X 30 Mtr. Head (For Ips Mc Land) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 7800 Lpm X 30 Mtr. Head (For Ips Mc Land) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 11800 Lpm X 30 Mtr. Head (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 130 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 90 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 45 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips Mc Land) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 35 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips-2 Near Stp) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Non Clog Sewage Submersible Pump Motor Rating Of 75 Hp Compatible To Work With Cable Length Of 100 Meters. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For Ips-2 Near Stp) , Non Clog Sewage Pump: Supplying, Erection, Testing And Commissioning Of Submersible Motor Pumping Set Non Clog For Sewerage Having Head Below Mentioned As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked. 9600 Lpm X 20 Mtr. Head (For Ips-2 Near Stp) , Hsr Itmes
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Contract Date: Ref. Documents Contract Value : 2,310
Statutory Bodies & Commissions/Committees No of Bidders 3
15.
Petroleum and Natural Gas #11114647 Technical Bid
Tender for Supply , Supply Of Abb Make Di818 Digital Input Module (32-Channel, 24 V Dc) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Supply Of Abb Make Do818 Digital Output Module (32-Channel, 24 V Dc) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Supply Of Pm867 Redundant Processor Unit Along With Required License And All Essential Controller-Level Hardware, Sm812 Safety Module With Required License And Software For High-Integrity Safety Processing, Bc810 Cex Bus Interconnection Unit For Establishing Communication Between The Main Controller And Installation Of Clusters, Ci867 Redundant Modbus Tcp/Ip Interface Module Along With Required License For Reliable Third-Party System Communication, Tb840 Redundant Optical Module Bus Cluster Modem For Long-Distance Fiber-Optic Cex Connectivity, Tu848 Termination Unit For Tb840 Optical Module Bus Cluster Modem , K811 Pof Cables Required For Providing The Optical Communication Link Between Controller And Remote Installation Of Station For The Abb Esd Plc System. , Supply Of Ai880 High Integrity Redundant Analog Input Module (8 Channels, Sil3 Certified) Along With Tu844 Mtu For Secure Wiring And Module Termination Of Redundant Analog Installation Of Signals, Barriers For Analog Signals And Ty801 Shunt Stick To Facilitate Loop Testing, Simulation, And Maintenance Of Analog Field Instruments For Integration With The Abb Esd Plc. , Supply Of Abb Make Di880 High Integrity Redundant Digital Input Module (16-Channel, Sil3 Certified) Along With Required Terminal Bases,Relays And Barriers For Digital Signals,Line Monitoring Relay And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules , Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With Abb Esd Plc. , Supply Of Abb Make Do880 High Integrity Redundant Digital Output Module (16-Channel, Sil3 Certified) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules, Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With The Abb Esd Plc. , Supply Of 42U Rack Enclosure Cabinet For Marshalling/System Cabinet, Along With Sd834 20A Industrial Power Supply Units And Ss823 Power Voting Units To Ensure Redundant, Uninterrupted Power Delivery And Accessories Like Limit Switches, Fftdu, Earthing Arrangements, Breaker, Spd Type 1+2,Fuses, Liu, Media Converter, Terminal Blocks, Required Interpanel Cables And Connectors, Earthing Cables, Power Cables, Wiring Etc Complete As Per Specification. , Supply Of Ups Power Distribution Board Panel With Accessories For Powering Panels And Any Other Tas Equipments Where Ups Power Are Required For Smooth Un-Interrupted Operation. Miscellaneous Instrumentation Comprising Of Suitable Mccbs For Isolation, Mcb Etc Are To Be Provided. The Panel Shall Be Complete In All Respects With Necessary Indication Lamps For Powering, Necessary Control Wiring With Digital Voltmeter & Digital Ammeter Separately For Ups And Auxilliary Supply For Front And Rear Seperately Etc. , Services , Installation, Integration, Testing And Commissioning Of Abb Make Di818 Digital Input Module (32-Channel, 24 V Dc) Along With Required Terminal Bases And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Installation, Integration, Testing And Commissioning Of Abb Make Do818 Digital Output Module (32-Channel, 24 V Dc) Along With Required Terminal Bases And Accessories Consisting Of Abb Make Tu818 Compact Terminal Base (50 V) For Field Wiring Termination And Modulebus Distribution, Abb Make Ci840a Profibus Dp-V1 Interface Module For Communication Integration, And Abb Make Tu847 Terminal Base For Ci840 To Provide Profibus Termination And Backplane Connectivity, Supplied As A Complete Compatible Assembly For Integration With 800Xa Based Dcs System. , Installation, Integration, Testing And Commissioning Of Pm867 Redundant Processor Unit Along With Required License And All Essential Controller-Level Hardware, Sm812 Safety Module With Required License And Software For High-Integrity Safety Processing, Bc810 Cex Bus Interconnection Unit For Establishing Communication Between The Main Controller And Installation Of Clusters, Ci867 Redundant Modbus Tcp/Ip Interface Module Along With Required License For Reliable Third-Party System Communication, Tb840 Redundant Optical Module Bus Cluster Modem For Long-Distance Fiber-Optic Cex Connectivity, Tu848 Termination Unit For Tb840 Optical Module Bus Cluster Modem , K811 Pof Cables Required For Providing The Optical Communication Link Between Controller And Remote Installation Of Station For The Abb Esd Plc System. , Installation, Integration, Testing And Commissioning Of Ai880 High Integrity Redundant Analog Input Modules (8 Channels, Sil3 Certified) Along With Tu844 Mtu For Secure Wiring And Module Termination Of Redundant Analog Installation Of Signals, Barriers For Analog Signals And Ty801 Shunt Stick To Facilitate Loop Testing, Simulation, And Maintenance Of Analog Field Instruments For Integration With The Abb Esd Plc. , Installation, Integration, Testing And Commissioning Of Abb Make Di880 High Integrity Redundant Digital Input Modules (16-Channel, Sil3 Certified) Along With Required Terminal Bases,Relays And Barriers For Digital Signals,Line Monitoring Relay And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules , Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With Abb Esd Plc. , Installation, Integration, Testing And Commissioning Of Abb Make Do880 High Integrity Redundant Digital Output Modules (16-Channel, Sil3 Certified) Along With Required Terminal Bases, Relays And Barriers For Digital Signals And Accessories Consisting Of Abb Make Tu842 Terminal Base/Mtu For Redundant Digital Installation Of Modules, Providing Field Wiring Termination, Redundant Modulebus Connection, And Backplane Interface, Supplied As A Complete Compatible Assembly For Integration With The Abb Esd Plc. , Installation, Integration, Testing And Commissioning Of 42U Rack Enclosure Cabinet For Marshalling/System Cabinet, Along With Sd834 20A Industrial Power Supply Units And Ss823 Power Voting Units To Ensure Redundant, Uninterrupted Power Delivery And Accessories Like Limit Switches, Fftdu, Earthing Arrangements, Breaker, Spd Type 1+2,Fuses, Liu, Media Converter, Terminal Blocks, Required Interpanel Cables And Connectors, Earthing Cables, Power Cables, Wiring Etc Complete As Per Specification. , Installation, Integration, Testing And Commissioning Of Ups Power Distribution Board Panel With Accessories For Powering Panels And Any Other Tas Equipments Where Ups Power Are Required For Smooth Un-Interrupted Operation. Miscellaneous Instrumentation Comprising Of Suitable Mccbs For Isolation, Mcb Etc Are To Be Provided. The Panel Shall Be Complete In All Respects With Necessary Indication Lamps For Powering, Necessary Control Wiring With Digital Voltmeter & Digital Ammeter Separately For Ups And Auxilliary Supply For Front And Rear Seperately Etc.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Maharashtra View Result →
16.
Heavy Industries and Public Enterprises #11111673 Technical Bid
Rate Contract For 24V Dc Smps Charger System For Various Projects For One Year , Charger Rating Range 20-70 Amps, 24V Dc Smps Charger & Dcdb (Integral Or Separate Panel) With 9 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 71-140 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 11 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable For Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 151-210 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 13 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 226-280 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 21 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 301-350 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 23 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable For Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 375-420 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 27 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 451-490 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 29 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 526-600 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 30 Feeders In Each Dcdb, Bhms (For 19Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 601-650 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 32 Feeders In Each Dcdb, Bhms (For 38Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 651-700 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 36 Feeders In Each Dcdb, Bhms (For 38Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 701-750 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 38 Feeders In Each Dcdb, Bhms (For 38Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 751-800 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 42 Feeders In Each Dcdb, Bhms (For 38Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Charger Rating Range 801-840 Amps, 24V Dc Smps Charger & Dcdb( (Integral Or Separate Panel) With 49 Feeders In Each Dcdb, Bhms (For 38Cells Battery) With Connectivity To Dcs With Cable & Lugs, Serial Link With Modbus Protocol With 100Mtr Cable Connecting To Dcs, Glands And Lugs For All Cable Tremination In Charger /Dcdb/Battery & Any Other Item As Required As Per Technical Specification , Discharge Resistor Bank For Charger Rating Range 226-280 Amps , Discharge Resistor Bank For Charger Rating Range 375-420 Amps , Discharge Resistor Bank For Charger Rating Range 451-490 Amps , Discharge Resistor Bank For Charger Rating Range 526-600 Amps , Discharge Resistor Bank For Charger Rating Range 601-650 Amps , Discharge Resistor Bank For Charger Rating Range 701-750 Amps , Discharge Resistor Bank For Charger Rating Range 751-800 Amps , Discharge Resistor Bank For Charger Rating Range 801-840 Amps , Discharge Resistor Bank Shall Be 427V 440A Rating With Forced Air Cooling To Be Supplied In Ennore Project , Laptop Shall Be Supplied If Required For Commissioning Or Operation Of The System (1 For Each Project) , Pdb With 16 Nos. Of Feeders For Charger Rating Range 71-140 Amps , Pdb With 32 Nos. Of Feeders For Charger Rating Range 226-280 Amps , Pdb With 72 Nos. Of Feeders For Charger Rating Range 701-750 Amps , Pdb With 180 Nos. Of Feeders For Charger Rating Range 651-700 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 20-70 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 71-140 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 151-210 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 226-280 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 301-350 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 375-420 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 451-490 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 526-600 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 601-650 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 651-700 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 701-750 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 751-800 Amps , Mandatory Spares For 24V Dc Charger As Per Technical Specification For Charger Rating Range 801-840 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 20-70 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 71-140 Amps , Erection Supervision & Commissioning Of Complete Charger System Forcharger Rating Range 151-210 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 226-280 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 301-350 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 375-420 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 451-490 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 526-600 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 601-650 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 651-700 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 701-750 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 751-800 Amps , Erection Supervision & Commissioning Of Complete Charger System For Charger Rating Range 801-840 Amps , Training To End User (5 Man Days Including 2 Mandays At Oem Works X 3 Projects) , Freight Charge For Complete Scope Of Main Supply Of 24V Dc Charger To Project Sites , Freight Charge For Complete Scope Of Mandatory Spares Of 24V Dc Charger To Project Sites
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
17.
Defence #11097521 AOC
Tender For Provision Of One Mega Watt Solar Power Project Under Ge (I) (P) No 2.; 1 Supply and fixing of MS fabricated office container of size 15x8x8.5 feet with toilet cabin of size 5x4 feet for SCADA panel and local monitoring for accomodating portable shelter , office, or living space in high alttitude cold region with including PCC flooring work for installation of container including fixing arrangement completeall as specified and directed.Location conditionTemparature range -30 °C to +25°CAltitude -3500m above sea levelwind speed upto 120 km/hSnow load high (snow accumulation on roof)Readymade container shall include the following(a) Attached toilet with EWC/IWC pressure jet gun, water tap, exhaust fan, corner wash basin, tiles flooring, water tank stand , gyser provision, wall mixer and other accessories required for said locations conditions. 2 (b) Container shall include bottom frame 100mmx50mm C channel ISI marked, Top frame of size 50mmx50mm MS square pipe ISI marked , stiffener bottom 100mm x50mm, 50mmx25mm, 25mmx25mm MS square pipeISI marked stiffener top 50mmx25mm, 25mmx25m MS square pipe ISI marked, side post 50mmx50mm, 50mmx25mm MS square pipe ISI marked, Side wall stiffness specially formed CR sheets of thicknes 1.2mm internal wall panelling 8mm thick MDF and all vertically and horizontal corner will be nealty and smoothly finished with aluminium section and L angle, Roof outside 1.2mm thick sheet of make properly sloped and water tight, false ceiling 9mm thick and smoothly finished with aluminium section and L angle, flooring 18mm thick cemented board of make visaka industries will be fixed by means of self taping screw and 1.5mm thick PVC vinyl carpet will be fixed on the panel (100% water termite and dimensional proof with veyl carpet) Aluminium windows double shutter sliding aluminium powder coated windows of thickness of 1.2mm with 4mm thick glass of make saint Gobin for all windows safety grill from outside and canopy above the floor frame work by tubular pipe of 25x25, Door with lock and handles with hydraulic door closer. Insulation 25mm thick glass wool insulation of density 65kg/m3 on side wall and 50mm on ceiling , all wiring will be PVC insulated copper wires of ISI quality, suitable for 240 volts 50 bukhead, switches and socket of 6Amp of ISI make. Split air conditioner point 16Amp alongwith seperate MCB earthing point will be provided for safety. Outside painting with 1 coat of Epoxy primer with 2 coats of epoxy paint and specially formed hooks for easy lifting and shifting. 3 Material and Labour for Plain fillets 2nd class softwood . square, rectangular or triangular in section, clean sawn, secured with screws of size exc 13 and not exc 25 Sqcm complete all as specified and directed. 4 Material and Labour for for prepration of wooden surfaces and applying a coat of pink primer for filletsof surface of any description not otherwise described over 10cm in width or girth complete all as specified and directed. 5 Material and Labour for50mm thick bonded mineral wool blanket slab made from rock, density 48kg/Cum and fixed as per manufactures instruction complete all as specified and directed. 6 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on walls complete all as specified and directed. 7 Material and Labour for 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with nails on ceiling complete all as specified and directed. 8 Material and Labour for cement concrete type D2 1:4:8 (40mm graded agg)as in foundations filling mass concrete and all as specified and directed. 9 Material and Labour for Pre-cast cement concrete block masonry with solid blocks in 1:3:6 type C-1 using20mm graded crushed stone aggregates, exc. 10 cm in width or girthand setting in mortar 1:6, complete all as specified and directed. 10 Material and Labour for 100mm thick cement concrete 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring finished even and smooth without using extra cement complete all as specified and directed. 11 Material and Labour for renderring 15mm thick in CM 1:4 on fair faces of concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. 12 Material and Labour for renderring 15mm thick in CM 1:4 on stone masonry surfaces finished even and smooth without using extra cement complete all as specified and directed. 13 Material and Labour for Walling of random rubble masonry, uncoursed well bonded bedded and solidly hearted built in CM 1:4 and flush pointing the surface in contact with earth in same mortar as the work proceeds complete all as specified and directed. 14 Supply and fixing of50mm thick PUF insulated water tank of capacity 5000 litres complete all as specified and directed. 15 Supply and fixing of50mm thick PUF insulated water tank of capacity 1000 litres complete all as specified and directed. 16 Supply, installation, errecting ,testing and commissioning of On grid connecting on ground Mono Perc half Cut Bifacial Solar photo voltaic (SPV) generation plant of capacity 825KWp DC capacity at standard test condition and750 KW AC capacity (Net capcity after derating), at CHUMATHANG for fixed on module mounting structure without tracking component including solar grade copper cable of suitable sizes upto Invertor,UPS for auxilliary supply to SCADA, string array combiner/ array junction boxes comprising of following sub components/sub systems including all necessary protection, control switches and relays as required for smooth functioning of the system and meeting the specifications as given and directed by Engineer-In-Charge, the quoted rates includes all components/accessories as given below and required from Solar panel to upto step up transformer 1000 KVA incomer termination complete all as specified and directed. 17 (A) Solar photo voltaic plant- : To obtain cumulative 825KWp, three tables of nearly equal size table (varaiation of 5% between table size is permissible) ofthe input of mono perc Half Cut Bifacial silicon solar PV modules of minimum or more than 540/545 Wp with minimum or more than 144 Nos solar cells preferably per module of standard size and weight as per NISE standard , frame anodised aluminium frame (double walled) with junction box IP 65 rated , each having efficiency more than 21% at standard test condition, fill factor more than 0.79 performance ratio equal to and greater than 78 % & made of high transmittivity glass as per NISE standard tempered and glass front surface shall give high encapsulation gain. (transmittance above 90% and bending less than 0.3%) Electrical parameters of 540/545 Wp solar PV module under STC of irradiance 1000 W/m2 , AM 1.5 Spectrum at temperature 25° C will be as under or higher :-Min Peak power Pmax : 540/545 Wp or higher, Current at Pmax Ipm : 12.97A Voltage at Pmax Vpm : 41.65 Volt Short circuit current Isc : 13.85 A Open circuit voltage Voc : 49.50Volts , Maximum series fuse rating : 30A (i) Rated output of modules shall have positive tolerance of minimum 3% & no negative tolerance is allowed. (ii) It shall perform satisfactorily in relative humidity 100% with temperature -35° C to +35° C (Cell) and should withstand wind 198 Km/Hr on the surface of the panel. (iii) PV modules must be warranted for their output peak watt capacity, which shall not be less than 90% of the initial value at the end of 10 years and 80% of the initial value at the end of 25 years. (iv) The temperature co-efficient for the module shall be suitable for CHUMATHANG (UT Of Ladakh) climatic conditions. Variation of higher capacity Solar PV panel is permissible subjected to that performance parameter of the panel shall be equal or better than given above.v) PV module must confirm to latest edition of IEC 61215/IS14286 and as specified here-in- after in particular specification In addition, the modules must confirm to IEC 61730 Part-I & II for construction and testing & safety qualification. (vi) It shall also in conformity of latest technical specifications issued by MNRE from time to time (vii) Provision of earthing & earth strip/cables etc. for earth for solar PV module/Array etc. as per latest IS/MNRE norms to be provided and the cost of the same is to be included in this item and no extra amount will be paid to the contractor on this account.Notes: On SPV (i) The specifications and capacities of plant equipments shall be designed to confirm and achieve the minimum of efficiency and performance guarantees as laid down in this bid documents. These design details and other technical details shall be submitted by contractor on commencement of contract as early as possible but not later than one month(ii) The installed system should be such that during the day, the power needs should be first met by Solar energy. In case the solar energy production is less than the required, the deficit power should be pulled from the exsiting DG set supply .(iii)The contractor shall obtain the approval of make for the proposed SPV module from accepting officer complete system of 825 KWp Solar photo voltaic (SPV) (iv) Any necessary item required for functioning of SPV but not catered in the contract will be deemed to be included in the quoted rate and nothing extra will be admissible on this account 18 .(v) Site clearance incl removal of boulders to a distance 250 m to 500m to be carried out before execution of work. Amount required for site clearance is deemed to be inclulded in the amount quoted by Contractor against this item. Contractor is advised to visit the site before quoting the rate. (vi) Country of origin for solar cell & PV module must confirm to ALMM APPROVED LIST OF MNRE.(B) String array combiner/Junction Boxes: Supply & fix suitable Numbers of dust, vermin and waterproof Array string array combiner/Junction Boxes and main junction boxes made of FRP/Thermo Plast with IP65 protection in compliance with IEC62208 and shall be sunlight /UV resistant a well of fire retardant including over voltage protection, surge protection and maintenance free earthing as per relavant standard. The string array combiner/Junction boxes shall have suitable arrangement of followings:(i) Strings are required to be connected to the busbar through individual fuses. Provide arrangement fordisconnection for each of the groups (ii) Provide a test point for each subgroup for quick faultlocation & to provide group array isolation. (iii) Each array junction box will have suitable by pass &reverse blocking diodes for maximum DC blocking voltage of 1500V with suitable arrangement for its connection. Reverse blocking & by-pass diodes shall work for temperative extreames & shall have efficiency of 99.98% conformed by appropriate IEC standard. Note:- String array combiner/ junction box shall be carried out as per approved SLD.(C) Cabling : (i) Supply and fixing suitable size of XLPO insulated copper cable as per load of solar grade, 1800 V DC/1100 V AC or higher DC voltage rating, confirming to TUV 2 pfg 1169/08.2007 PV1F and latest IEC codes & IS codes for Solar Cables. (ii) All cables and connectors for use of installations shall be of solar grade which can withstand harsh environment conditions including high temperature, UV radians, rain. humidity, dirt, burial and attack by moss and microbes for 25 years and voltage as per latest IEC/IS in standards. (iii) All cables/wires shall be provided with UV resistance printed copper ferrules for DC side. (iv) Size of cable from PV module to invertor shall be minimum 6 sqmm 1 core multistranded copper UV protected solar cable to be provided. (v) Cable Batch No./Drum No., IS code & size make should be printed/embossed at every one metre. (vi) The wiring of modules interconnection shall be in suitable size GI/HD pipe. (vii) Size of wire - 3.70mm dia with tolerance limit (+/ -) 0.08mm. (viii) Size of aperture - 80mm x 100mm (ix) Woven double twisted, hexagonal shaped Zn + PVC coated wire mesh type 80 x 100mm of wire 3.70mm dia wire as per IS 16014. The wire used for the manufacture of wire mesh shall have minimum tensile strength of 350N/mm2 and elongation shall not be less than 10% in accordance with IS 16014.To be laid in DWC pipe of suitable size. (xi) Solar inverter to ACB Panel, connection aluminium XLPE conductor cable of size 185 sqmm x 3C 1.9/3.3 KV rating Note : Cost of interconnecting copper cable (AC & DC), Al XLPE cable from Solar Invertor to ACB panel and cable tray above upto inverter and LT panels and upto LT side of transformer as per site requirement at the location as directed deemed to include in the item quotated rates and no extra payment will be made to contractor on this account. LT Panel shall be paid seperately. 19 (D) Module Mounting Structure (MMS) : Supply, design & fixing support structure MS hot dipped galvanised (80Micrones) including PCC 1:2:4 type B-1 for each support / foundation for civil works (excavation and earth work cutting, grouting, PCC etc.) and fixing the mouting arrangement suitable for PV solar modules & to withstand minimum horizontal wind speed of 198km/hr. The mounting structure is of mild steel hot dipped galvanised. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from Solar PV panels. Nut bolts, supporting structures including module mounting structures shall have to be adequately protected from atmosphere and weather prevailing in the area. All fastners shall be of stainless steel of grade SS316. Two numbers of anti-theft fasteners of stainless steel on two diagonally opposite corner of each module shall be provided.Note: (i) Cost of interconnecting copper cables along with cable trays ( floor/ wall mounted ) suitable to accommodate solar grade cables & cables upto inverter is included in the item and no extra payment will be made to contractor. (ii) The module mounting structure shall be carried out as per approved drawing of foundation MMS. MMS foundation shall be designed as per IS 456:2000 and IS 13920:2016 and drawings shall be approved by GE before execution. (iii) The MMS stub/column,rafter,purlin ,ties and bracing members shall conform to following indian standard :IS 2062 -Hot rolled medium and high tensile structural steel ,IS 811-Cold formed light gauged structural steel section ,IS 1161-steel tube for structural purposes, IS4923- Hollow steel section for structural use. Minimum grade of steel sections for conforming to IS 811 and IS 4923 shall be E350 conforming to IS 2062 and Yst 310 conforming to IS 1608 respectively.(E) Lightning Protection for PV Array :- Supply & fix Lightning Arrestor of the required number of suitable Early Streamer Emission (ESE) lightning arrestors installed in the array field. Lightning arrestors/surge arrestors shall conform to IEC 60099-4 or IS:3070 except to the extent modified in the specifications. Arrestors shall be of hermetically sealed units, self-supporting construction, suitable for mounting on lattice type support with the following :-(i) The air terminal should be capable of racking the lightning stroke 60 micro seconds earlier as compare to passive lightning rod. (ii) The air terminal is Early Streamer Emission (E.S.E.) type which shall be fixed at the top of a GI elevation pole with base so as be at least 2 meters above the structure to be protected. Its height above roof level would be dependent on the level of protection and the protection radii required (iii) The air terminal should be working on the principle of early streamer emission using non-radioactve technology, needing no external power source. (iv) The air terminal is of stainless steel and it has qualified diameter to resist high values of lightning currents. (v) Roof connecting pipe should be capable of withstand in lightning strikes having dimension 50mm ID and 60mm OD. The terminal adaptor having inner dia 60mm OD. Lightening protection shall be provided as per approved Drg. 20 (F) Earthing system for PV array field :-Earthing system shall comply with latest revision andamendment of the relevent IEC standard and IS codes. (i) All PV module ,module mounting structure (MMS) and string monitoring unit (SMU) structures in the PV erray field shall be connected to the earthing system (ii) Each PV module frame shall be earth using copper wire of sufficient cross section area. Earthing complete with copper earth plate electrode 600×600 ×3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20x3 mm copper strip as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and 40mm dia GI pipe light grade for protection of earth strip and 20mm dia meduim grade for water funnel with wire mesh complete connected to earthing test point as per SSR Part-I 2009 all as specified and directed including testing on completion.NOTE:- Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(G) Solar Inverter : Supply, fixing, testing and commissioning of minimum of suitable capacity in suitable Nos as per 250/255 KW (Total capacity of Inverters shall not be less than 750/755 KW after derating with three inverter) for CHUMTHANG 50 Hz , 3 phase 800V,185A Grid Connected Solar inverter outdoor type suitable to convert DC power of solar PV module/array to AC for further feeding to stepup transformer conforming to IEC-61683 for efficiency, IEC-62109(1&2) or equivalent for safety & IEC-62093 for reliability. The input D.C. tech specification of inverter are as under and as per approved design.(i) Operating temperature :-40ºC to + 35ºC,(ii) Relative humidity (Non condensing) upto 95%.(iii) The inverter shall consist of associated control, protection, data loging device and remote monitoring hardware. the inverter shall be suitable for operation at Chumathang .Alt 4200 mtr and min - 40ºC temperature.(iv)The inverters shall have minimum protection to IP65 and minimum European efficiency 99% load as per IEC 61683 standard.(v) The inverter shall adjust voltage and frequency levels to suit the existing DG Sets/AC power supply. (vi) The inverter shall be self-commulated with pulse width modulation (PWM) technology and shall be capable of synchronize maximum within 1 minute.vii) Maximum power point tracker (MPPT) conforming IEC- 62093 shall be integrated in the inverter to maximize energy drawn from the solar PV array. (viii) The inverter shall include appropriate self protection & self diagnostic feature to protect itself and the PV array from the damage in the event of inverter component failure or from parameters beyond the inverters safe operating due to internal or external causes. 21 (ix) Inverter shall have protective arrangement against ground leakage faults, over voltage & over current. (x) Inverter shall have arrangement for adjusting DC input current & shall trip against sustainable fault down stream and shall not restart till fault is rectified. Notes: (i) If the solar inverter as specified here-in-before is not available in the market , contractor will provide the same of higher capacity as available in the market without any extra cost. (ii) All suitable size of copper cables as per load requirement from SPV systemto inverter for interconnection purpose shall be provided by the contractor and deemed to be included in quoted rates. (iii) Cost of all Copper plates earthing equipments including Copper earth strips from equipments to earth pit is deemed to be included in quoted rates.(H) Uninterrupted power supply(UPS) : Supply, installation, testing & commissioningof 110V/40A Float Cum Boost Battery Charger unit includingbattery bank comprising 50 Nos of 2 Volts-65 AH sealed maintenance free battery.The CCCV battery charger consisting ofcopper wound,air cooled transformer, 01 Set single phase full wave bridge rectifier consisting ofdiodes andSCRs, liberally rated mounted on heat sink andcomplete with resistor/condenser network for surge supperssion .During auto float mode automatic changeover shall take place from float mode to boost mode and vice versa, 01 Set of solid state constant potential controller to stabilize the DC output voltage of the float cum boost charger, 01 No electronic controller , DCdigital ammeter,DC digitalvoltmeter, Potentiometer , DC, MCB for reverse battery protection . The charger should have alarm annunciation with visual and audible alarm with manual reset facility forfuse fail alarm. Float cum boost battery charger and DC distribution board shall be housed in powder coated sheet steel cubicle with panels of 1.6mm thickness , louvers for ventilation , gland plate will be provided for cable entry from bottom .The battery charger shall be divided into two compartments.The upper compartment shall house the battery charger & DCDB with all necessary controls. The lower compartment shall be suitable for housing the batteries. Tech specification shall be as under:-(a) Input working voltage-180 -270 Volts(b) Nominal Input Voltage - 230 V , AC , 50 Hz,1 (c) On load input power factor- > 0.8 (d) On load unit watt efficiencies-> 80%(e) No load losses of complete charge-< 10% (f)Ripple contents on the load (RMS)= 1% to 5% (g) Over load - 110% for 30 minutes and will give visual indication for over load condition. (h) Boost charging - 2.4 V/Cell . (j)Float charging -2.15 V/Cell (k)Float cum boost charging-Automatically changes from one state to another state as per battery condition and will give the visual indication for either float or boost based on charging mode. (l)Reverse polarity -No damage will caused .A visual indication for reverse polarity will appear with an audio alarm. (m)Short circuit-MCB protecton provided. Make of battery charger. Statcon/Sinetrac/Amar Raja Make of batteries. Exide/Amaron/Okaya(n) The battery bank system shall be designed to supply power to following loads :-(i) SCADA(ii) Inverter auxillairy supply 22 (iii) Capacity of battery bank shall be done considering the above mention load at power factor of 0.8 lagging inclusive of 10% design margin at 50ºC.Note:- All suitable size of copper cables as per load requirement for interconnection to above loads here-in-before shall be provided by the contractor and deemed to be included in quoted rates(J) DATA ACQUISITION SYSTEM/PLANT MONITORING & SCADA :- Supply,fixing,testing and commissioning of SCADA system Monitoring system with 65 inch Screen at site with Local LDMS and for Remote Monitoring 55 inchs screen in Engineer-in-charge office to be provided for the performance of the SPV on cloud. plant, inverter ,power, array voltages, array currents & AC parameters,energy yield, temperature,irradiance level etc. and it could provides flexible interface to facilitate PC based inverter monitoring and control via GPRS modem and internet/ethernet connection. This should have include web visualization system and data logger with integrated ethernet port. (i) Data acquisition System shall be provided for each of the solar PV plant. (ii) Data Logging Provision for plant control and monitoring, time and date stamped system data logs for analysis with the high quality, including latest version available of PC & Printer. Metering and Instrumentation for display of systems parameters and status indication to be provided (iii) Solar Irradiance: An integration Pyranometer/Solar cell based irradiation sensor (along with calibration certificate) provided, with the sensor mounted in the plane of the array. Readout integrated with data logging system. (iv) Temperature: Temperature probes for recording the Solar Panel temperature and ambient temperature to be provided complete with readouts integrated with the data logging system.(v) The parameters like AC Voltage, AC Output current, Output Power, Power factor, DC Input Voltage, DC Input Current, Time Active, Time disabled, Time Idle, Energy Produced, Protective function limits (Viz-AC Over voltage, AC Under voltage, Over frequency, Under frequency ground fault, PV starting voltage, PV stopping voltage etc are accessible via the operating interface display in real time separately for solar power plant. (vi) All major parameters available on the digital bus and logging facility for energy auditing through the internal microprocessor and read on the digital front panel at any time and logging facility (the current values, previous values for up to a month and the average values) should be made available for energy auditing through the internal microprocesor and should be read on the digital front panel. (vii) PV array energy production: Digital Energy Meters to log the actual value of AC/DC voltage, Current & Energy generated by the PV system provided. Energy meter along with CT/PT should be of 0.5 accuracy class. (viii) Computerized DC String/Array monitoring and AC output monitoring shall be provided as part of the inverter and /or string/array combiner box or separately (ix) String and array DC Voltage, Current and Power, Inverter AC output voltage and current (All 3 phases and lines), AC power (Active, Reactive and Apparent), Power Factor and AC energy (All 3 phases and cumulative) and frequency shall be monitored. (x) Computerized AC energy monitoring shall be in addition to the digital AC energy meter. 23 (xi) The data shall be recorded in a common work sheet chronologically date wise. The data file shall be MS Excel compatible. The data shall be represented in both tabular and graphical form (xii) All instantaneous data shall be shown on the computer screen. (xiii) Provision for Internet monitoring and download of data including recharging shall be also incorporated till the duration of contract. (xiv) Software shall be provided for USB download with life time license and analysis of DC and AC parametric data for individual plant (xv) Remote Server and software for centralized Internet monitoring system shall be also provided for download and analysis of cumulative data of all the plants and the data of the solar radiation and temperature monitoring system. (xvi) Ambient /Solar PV module back surface temperature shall be also monitored on continuous basis. (xvii) Simultaneous monitoring of DC and AC electrical voltage, current, power, energy and other data of the plant for correlation with solar and environment data shall be provided. (xviii) Remote Monitoring and data acquisition through Remote Monitoring System with latest software/hardware configuration and service connectivity for online/real time data monitoring/control complete to be supplied and operation and maintenance/control to be encurred by the supplier. Provision for interfacing these data on Engineer-In-Charge Computer/display device and portal.NOTE:- The cost of all equipments , internet, ethernet connections, connected cables, Server, printer etc. are included in this item All licensee of windows server, MS office or any other software required for functioning of SCADA is deemed to be included in quoted rates for life time. Recharge of GPRS/3G/4G/5G network for 5 yrs from date of completion shall be reponsibilty of contractor and rates quoted are deemed to include the same. Training: On successful commissioning of the plant, training shall be provided on Plant operations and maintenance to a team (Engineers and Technician/Operations) as nominated by GE for 07 days at the time of handing over of solar plant after completion of phase-I.K) WEATHER MONITORING SYSTEM : Complete one set for Chumathag As a part of weather monitoring system the contractor shall provide the following measuring instruments with all necessary software and hardware required to integrate with SCADA.(i) Pyranometer : The contractor shall provide minimum 04 Nos of secondary standard pyranometer (ISO 9060 classification alongwith necessary assessories for measuring incidental solar radiation at horizontal and inclined plane of array. Specificiation of the pyranometer shall be asfollows:- Spectral response : 0.31 to 2.8 micron ,Time response (95%) : Max 15 second ,Nonlinearity ± 0.5% ,Temperature response : ± 2% ,Tilt error <± 0.5% ,Zero offset thermal radiation ±7W/Sqm ,Zero offset temperature change ± 2 W/Sqm ,Operating temperature range O ºC to 80ºC ,Non stability Maximum ±0.8% ,Resolution minimum +/- 1 W/Sqm : Output Analog 4-20 mA, ,Digital RS 485 Each instruments shall be supplied with necessary length of cable calibration certificate with calibration ,traceability to world radiation reference(WRR) or world radiation centre shall be furnished alonwith the equipments.The GE reserves the right to check the calibration at the expense of the contractor. 24 The signal cable length shall not exceed 20 m .The contractor shall provide instrument manual in hard and soft form.(L) Protection switch gears: Supply, installation, testing and commissioning of factory made outdoor type, LT panel weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick with internal partition of 1.6 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2000 Amp, outdoor type , frame factory fabricated , duly powder coated painting having thickness not less than 100 microns provided suitable gasket, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system, including the following :- (a)ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection. (b) MCCB 400 A, 4 pole, 415 volts, 50 Hz - 03 Nos (C) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 800 V duly moounted on porcelain insulators -01 Set (d) Digital amp meter 3 ph programmeable type with suitable1600 Amps -01 Set (e)Digital volt meter 3 ph programmeable type with suitable0- 800 volts -01 Set (g) CT 1250/5A/5A, PT 100VA CL 0.5/3P (h) LED phase indicator (RYB )-01 Set. All DC & AC circuits shall be suitably protected using appropriate circuit breakers and isolators, fuses and relays annunciator & system condition displays. Protection switchgears on AC side shall have LT ACB 1250 Amps capacity adjustable type , 4 pole 50 KA, 800 V, 50 HZ draw out type breaking capacity 50 KA( Icu=Ics=Icw=50KA) microprocessor protection based with overload ,short circuit over voltage, under voltage, over frequency , under frequency , earth fault and instantaneous over current protection unit , electrically operated with manual spring charge facility , having indication for earth /over load /overvoltage/ under voltage/ over frequency/ under frequency complete with digital meter. Note:- Panelshall be provided as per approved SLD.(M) Cable Duct / Conduit DWC Pipe : Cable duct/ cable tray of appropriate size from solar panel to inverter/ transformer and cable duct made from PCC etc incl MS plates duct cover 6 mm thick (plain orchequered) channels square cut or notched ( ordinary & counter sunk) forming holes without any attachment complete all as spd and directed.Note: (a) There should be provision of vertical separation between power and control cable duct. (b) Cable ductshall be provided as per approved drg . 25 Supply, installation testing and commissioning of outdoor type step up transformer Inverter duty type low losses of 1 MVA, 0.800/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/delta (Δ/Δ) complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5% in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 26 HV Bushing 33 KV and LV Cable Box suitable for chumathang area of Alt 4200 m along with necessary bus bars with adaptor box suitable for terminating incoming cables from inverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay trip contact and shut off valves. (ii) PRVRelay Trip (iii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iv) Winding temperature indicator with alarm and trip contacts (v) Marshalling box 200 TB (MK) -03 Nos (6 No of terminal , 3 phase primary and 3 phase secondary, Bolted or plu in type terminal, cable entry 3X 50 sqmm (primary) and 3 X 120 sqmm (secondary) cable ties, clips or trays ) (vi) Magnetic oil level gauge. (vii) Pressure release valve (PRV) with trip contacts.(viii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (ix) Oil level indicator with minimum level marking.(x) Thermometer pockets with thermometer. (xi) Silica gel breather (xii) Air Release plug. (xiii) Lifting Lugs (xiv) Earthing terminals (xv) Bi-directional Rollers (xvi) Anodized aluminum rating and diagram plate. (xvii) Off load Tap changer including indoor remote control panel. (xviii) Top filter valve (xix) Including transformer platform as per OEM recommendation is deemed to be included in quoted rates.Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM recommendation is deemed to be included in quoted rates (ii) Rates quoted is inclusive of all control cables of suitable size and core(as per manufacturer recommendations) from buchholz relay, PRV, OTI & WTI of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The step up transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 27 Supply, installation testing and commissioning of outdoor type distribution low losses as per Level II part I (IS:1180) of 1.25 MVA, 0.415/11KV, 3 phase, 50 HZ, ONAN Cooled oil immersed copper wound out door type Step up Transformer delta/star (Δ/Υ) (complete with first oil filling and other standard fitting / accessories and Off load tap changer (Taping Range ± 5 % in step of 2.5% each) suitable for feeding supply generated from solar power plant to existing transmission line with Including the following : 28 HV bushing and LV Cable Box along with necessary bus bars with adaptor box suitable for terminating incoming cables frominverter. Marshalling Box (having TTB Only ) all as specified and directed (i) Buchholz Relay with alarm and trip contact and shut off valves. (ii) Oil temperature indicator 150 mm dia with alarm and trip contact. (iii) Winding temperature indicator with alarm and trip contacts (iv) Marshalling box 200 TB (MK) -03 Nos (v) Magnetic oil level gauge. (vi) Pressure release valve (PRV) with trip contacts. (vii) Conservator with oil filling hole with cap and drain plug and wit built in diaphragm to avoid direct air contact with transformer oil. (viii) Oil level indicator with minimum level marking. (ix) Thermometer pockets with thermometer. (x) Silica gel breather (xi) Air Release plug. (xii) Lifting Lugs (xiii) Earthing terminals (xiv) Bi-directional Rollers (xv) Anodized aluminum rating and diagram plate. (xvi) Off load Tap changer. (xvii) Top filter valve (xviii) Differential relay protection for power transformer Following protections shall be integrated with RMU Necessary equipments/metering devices shall be instaled in transformer.(a) Instantaneous overcurrent (b) AC time over current (c) Neutral & residual instantaneous over cuurent (d) Neutral & residual time overcurrent (e) master trip (f) anti pumping (g) trip circuit supervision (h) DC failure (i) WTI and OTI (j) pressure relief (k) Buchholz (l) Differential protectionNOTE:-The following works /items shall deemed to be included in the above quoted rates and no extra payment shall be made to the contractor on this account. (i) The erection /installation of transformer with suitable size of foundation as per OEM design is deemed to be included in quoted rates .(ii) Rates quoted is inclusive of all control cables of suitablesize (as per manufacturer recommendations) from different relays buchholz relay of power transformer to various controls ie CTS/PTs & HT panel and control panels. (iii) LT single core cable /LT bus bar of suitable size and capacity from LT panel to step up transforemers LT side including appropriate size of cable lugs as required at site for connection complete all as specified and directed. (iv) The transformer shall be suitable for inverter input to avoid/reduce/capable for odd harmonics and heat losses. 29 Supply, installatioon , testing and commissiooning of factory made outdoor type 4 Way 2x630 Amp SF6 + 2x630Amp LBS out door type 11 KV Ringmain Unit with Space Heater at Altitude 4200m, 630 Amps IAC 20 KA for 3 sec suitable for solar power system confirming to relevant IS/IEC, LSC 2B having following specification and comprising of following:- (i) Electrolytic copper bus bars, droppers and bus bar should be insulated with full system voltage sleeves. Each SF6 breaker shall comprise of following 30 (ii) Trolly mounted vaccum circuit breaker as per IEC-62271-100 SF6 circuit breaker should have three Nos resin encapsulated vaccum bottles.(iii) Motorized spring charging mechanism 230V AC 50 Hz with integral spring charging handle for manual spring charging. (iv) Cast resin current transformer 11KV, 200/1-1A, Core-I: class 1.0, 5VA, core2:5P10,5VA.Bushing shall be of 11 KV (v) Cast resin potential transformer 11KV/√3/110V, 50VA, class 0.5Cl 3P, bushing shall be 11KV KV and HT fuse at the primary end and 4P MCB at secondary end of PT. (vi) Accessoories like local/remote switch, breaker control switch (T-N-C) space heater with thermostat, DC and AC control circuit through MCB, indicating lamps for RYB, spring charge, DC supply healthy, breaker ON/OFF , breaker in SERVICE/TEST. (vii) Multifunction meter with RS 485 port , on MODBUS Protocol. (viii) Digital ammeter and digital voltmeter. (ix) Master trip relay-01 No and Aux relay TCS, DC Fail, OC & E/F (x) Comprehensive numarical protection relay on MODBUS protocol compatiable for directional and non directional O/C, E/F, U/V, O/V protection, Pressure switch or gas density monito, Frequency relay, Breaker failure protectionTransfomer protection Bucholz protection, PRV,Differential protection, OTI, WTI Relay and panel should have following additional facilities:- (xi) Trip Ckt supervision, AC fail, DC fail (xii) Disturbance recorder. (xiii) Event log with date and time (xiv) Measurment and control feature (xv) Fully internal arc type tested. (xvi) SF6 bottles should be epoxy encapsulated. (xvii) Racking in/out, manual closing/tripping of CB with compartment door closed. (xviii) Breaker shall be provided with following contacts:- (xix) Auxilary switch with 6 No + 6 NC mounted on the draw out portion of the switchgear. (xx) Position switch with 3 NO + 1NC contacts for eachposition in SERVICE and TEST.(xxi) 16 window annunciater with hooter/alarm for OC,SC,OV,UV,TCS,DC Fail, AC Fail OTI,WTI,PRV,Bucholz, Differential, OF, UF, Gas density low, Breaker failure protection 31 Material and Labour for Earthing complete with GI earthplate electrode 600mm x 600mm and not less than 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level connected to GI strip of size 32x6mm by means of bolts, nuts, check nuts and washers of GI/steel all as shown in electric plate No 3 connected to equipmentscomplete and including char coal dust & salt filling in alternate layers (each layer shall be 15 cm thick)and GI protection pipe, medium grade 40mm dia and GI watering pipe 20mm, medium grade with funnel and wire mesh, 40mm thick pre-cast RCC, M-15 (nominal mix) cover reinforced with XPM weight not less than 4kg/sqm with suitable handle of 6mm dia MS bar and angle iron 40 x 40 x 3mm frame for cover, PCC M-15 (nominal mix) pit, excavation and earth work in any type of soil and connectedcomplete all as specified and directed. 32 Material and Labour for earthing complete with and including copper earth plate electrode 600 mm x 600 mm x 3.15 mm surrounded by a mixture of charcoal and salt in alternate layers burried directly in ground vertically in a pit of depth not less than 2.25 m deep below ground level with top edge of earth plate at a depth of not less than 1.5 m below ground level, connected to copper trip earth lead wire 25x6 mm dia by means of nuts, bolts, checknuts and washers made out of galvanised iron, 15 mm bore (light grade) GI pipe for protection of earthing lead, 20 mm bore (light grade) GI pipe for watering with funnel, wire mesh and including necessary excavation and earth work, PCC 1:2:4 type B-1 pit and 50 mm thick RCC M-25(Design mix) reinforced with XPM (weight not less than 3 kg/sq m) pit cover, C.I frame, charcoal and comman salt filling in alternate layers, complete all as shown and specified in electrical plate No. 3 of SI Part-I. 33 Material and Labour for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr belowground level connecting to galvanisedearth lead wire 4mm dia by means of bolts,check nuts and washers and earth lead protected by provision of GI pipe light grade 15mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, connecting to test pointwith fixing arrangement, funnel, wire mesh and earth work in hard/dense soil,returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3all as specified and testing on completion. Note :- Cost of earth lead upto 7.5 mtr and GI 15mm bore pipe is deemed to be included in unit rate. 34 Supply, installation, testing and commissioning of factory made, DG disribution cum DG syncronization panel of suitable size, outdoor type made out of CRCA sheet 3.15 mm thick with partition of 1.6 mm, frame factory fabricated with front and back openable double door with locking arrangement, with MS angle section 50x50x6 mm support, duly powder coated painting having thickness not less than 100 microns provided suitable gasket to make it dust and vermin proof, suitable for 3 Phase4 wire, 415 Volts, 50 Hz, AC supply system,comprising of following :- (a)Distribution panel with ACB 2500Amp microprocessor release operation type, 415 Volt 50 KA 1 Nos 2500 Amp ACB (b) DG Synchronizing panel- DG Sync Panel with double busbars required for sync 3 nos 400 KVA DG set after Sync Power fed to 2500 Amp Distribution Panel (c)Control Ckt require for DG Sync With PV System, Logic of this control ckt : DG 1, 400 KVA on all time with minimum 30% load and when load increase 80% DG2 400 KVAstart and so on for all 3rd Nos 400 KVA DG) Note: DG syncronization panel shall be provided as per approved SLDcomplete all as specified and directed.. 35 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1.9/3.3 KVgrade, cross-sectional area 400 Sqmm 3 core for solar ACB panel to inverter duty transformercomplete all as specified and directed. 36 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size400 Sqmmcomplete all as specified and directed. 37 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 Sqmm 3.5 corecomplete all as specified and directed. 38 Material and Labourfor Sand cushing to under ground cable, provided with 8 cms thick layer before laying the cable and 15 cm thick after laying and streching the calbe complete all as specified and directed. 39 Supply and laying unreinforced precast concrete cable cover on the cable in the trench,classl LV, Type-I, flat size 250mm X150mmX50mm(1100 volts LT cable)complete all as specified and directed. 40 Supply and laying Unreinforced precastconcrete cable coveron the cable in the trench , class HV, Type-I, flat size 300mm X180mmX50mm (for 11KV HT cable)complete all as specified and directed. 41 Material and Labour for Solar HT Generation meter AC three phase, multifunction net meter of accuracy class 0.5s, rated voltage 110 V Ph-Ph or 3 X 63.5 V Ph-N, voltage range + 15% to - 30% of rated voltage, basic current 1 Amps or 5 Amps, maximum continuous current 2 times (200%) of basic current , starting current 0.1% of basic current, frequency 50 Hz and operating frequency range 47.5 to 50.5 Hz , IP 65 protection, Protection: over voltage, over current, over/ under grid frequency, over temperature, short circuit. with optical & RS232 port, backlit LCD display, (measures import kWh, kVAh, Export kWh, kVAh , Net kWh, kVAh, V,I, kW, 6 month history of energy, load survey, tamper detection & logging, power On/Off events, instantaneous parameters of rating -/5A with display in absence of powercomplete all as specified and directed. 42 Shifting of DG set of capacity 3 x 400 KVA from location Upper and lower chumathang (Upto 2 Km) near to SPV plant location with all connected items including installation, connection with cable, making of suitable size as per existing 3 Nos PCC plateform of 400 KVA DG set all as per specified and directed 43 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 630 Sqmm 3.5 corecomplete all as specified and directed. 44 Material and Labour for Rolling and consolidation formation surface in cuttingto required camber and gradient with 8 to 12 tonne power roller complete all as specified and directed. 45 Material and Labour for soiling (or Sub Base) 200mm thick (Spread thickness) with broken boulders or quarred stone interstices filled, surface formed and surface formed and rolled and consolidated torequired gradient and camber with 8 to 12 tonne power roller, complete all as specified and directed. 46 Material and Labour for cement concrete work in pavement/hardstanding of flexural strength 40 kg/sqcm in field using 400 kg of cement per Cum for thickness of concrete 20 cm including brooming the surface complete all as specified and directed. 47 Material and Labour for forming contraction (Dummy) joints 80mm deepx 10mm wide filled with sealing compound grade B complete all as specified and directed. 48 Material and Labour for forming 20mm thick expansiion joints filled with preformed bituminous filler and top 30mm primed and sealed with sealing compound grade B for 200mm thickness of concrete slab complete all as specified and directed. 49 Material and Labour for 150mm thick (compacted thickness) WMM in two equal layers 75mm thick each layer with coarse aggregates of lime stone, sand stone flint or quartizite of grading 2 (63 to 40mm size) spread, rolled and consolidated to required gradient and camber with 8 to 12 tonne power roller complete all as specified and directed. 50 Material and Labour for Cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundation filling and mass concretecomplete all as specified and directed. 51 Material and Labour for Cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in benching, coping around poles (aove GL) etc including weathering slightly rounded or chamfered angles and fair finshing the exposed surfaces or concrete using extra cement cmplete including necessary form workcomplete all as specified and directed. 52 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity750 KVA, Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ C including platform as per OEM recommendation is deemed to be included in quoted rates (For lower Chumathang) 53 Supplying, installation, commissioning and testing of transformer step down 11/0.415KV capacity400 KVA,Level II, IS 1180 Part I, out door type copper wound 3 phase, 4 wire, 50 cycles per second, oil immersed naturally cooled external cooling tube core type delta connection on primary side (HV side) and star connection on secondary side (LV side) having tapping 0,± 2.5%, ±5%, ±7.5% to be charged by means of hand operated, off load/tap changing gear including first filling of new transformer oil of dielectric strength not less than 60 KV with standard fittings such as two earting terminals for body and one additional for neutral brought out inbushing, oil level gauge indicator for level minimum and maximum, lifting lugs, rating and termina plate, plain breather device to prevent ingress of rain water and inserts, drain cum sampling valve 20mm bore steel with plug,dial type thermo meter, oil filling hole 32mm threaded with plug. The transformer shall be powder coated for water/dust and vermin proof. Note :- (1) Transformer oil shall be conforming to requirements of IS-335-1983 specification for newinsulating oil for transformers.(2) Equipment shall be suitable to operate at 4200 mtr above MSL at temperature variation between -35˚C to (+)35˚ Cincluding platform as per OEM recommendationis deemed to be included in quoted rates (For additional pocket & Upper chumathang)complete all as specified and directed. 54 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-55 (11 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.(For two/ four pole structure) Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely.complete all as specified and directed. 55 Material and Labour for Switch air break gang opertated tripple pole mechanically operated from ground level mounted, outdoor type suitable for vertical instatllation single break provided with locking arrangement for operating handle with lock consisting of mild steel channelHT post top insulator copper alloy high pressure assembly 33 KV grade complete with all accessoriescomplete all as specified and directed. 56 Supply & fixing lightning arrestor, high tension, polymer type gapless complete with all fitting transmission class, of capacity 33 kilo voltscomplete all as specified and directed. 57 Material and Labour forCross arms, bracing , supports, clamps and aback plates ,fabricated out of structural steel sections incuding nuts, bolts,washers,welding,bending cold or hot, drilling holes for bolts in any shape or size as indicated or coat of red oxide zinx chrome primer, one under coat and one finshing coat of aluminium paint complete all as specified. 58 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 185 Sqmm 3 corecomplete all as specified and directed. 59 Supply, laying, testing and commissioning of aluminium conductor, XLPE insulated, PVC inner sheathed, GI strip or wire armoured & overall PVC sheathed cable of 11 KV (Earthed) grade in trenchesl/ in GI pipe including dressing and clamping the cable with MS clamps of cross section area 120 Sqmm 3 corecomplete all as specified and directed. 60 Supply and fixing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing meterial and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 sqmm to 185 sqmmcompleted all as specified and directed. 61 Material and Labour for ACSR conductor for the provision of HT OH lineof sizes,3 of 6/1X3.0 (Ferret), 3 of 6/ 1x2.59 ( weasel) completed all as specified and directed. 62 Material and Labour for galvanised steel wire of4 mm dia with hooks stretching kinks and bends completed all as specified and directed. 63 Anticlimbing devices spikes type fabricated out of MS bars (round square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and shown on drawings. 64 Supply and fixing pin type 10 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of pin insulator completed all as specified and directed. 65 Supply and fixing disc type 90 KN polymer type, porcelain, viterous white, brown or green insulator including one mild steel spindle,for 33000 volts grade incl all accessories for fixing of disc insulator completed all as specified and directed. 66 Supply and fixing of Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letter, figures and conventional skull and bones in signal red colour and fixed with M.S clamps, bolts and nuts of approved size, for HT,25x20cm sizecomplete all as specified and directed. 67 Material and Labour for Galvanised steel tubing light grade 80 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 68 Material and Labour for Galvanised steel tubing light grade 100 mm bore laid in trenches orfix to wall/hole with fitting as required for cable protectioncomplete all as specified and directed. 69 Material and Labour for stay assembly complete using stay rod of 20 mm dia complete with accessories as shown in electric plate no 1 of SSR-2009 Part -I complete all as specified and directed by Engr-in-Charge Note: (Unit rate quoted by contractor herein before also includes earth work and PCC work ,Loop type insulator ,stay clamps ,nuts ,bolts ,washers and concretecomplete all as specified and directed. 70 Material and Labour for galvanised stay strand, size 7/4 mmcomplete all as specified and directed. 71 Supply and fixing of loop type porcelain vitreous white ,brown or green insulator large size with overall dimensions 90x140 mm,clearance of hole 25.5 mm complete all as specified and directed 72 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 2200 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 73 Under composion of following.(LT panel No-01 Lower Chumathag)(i)ACB 415 V, 4 pole, 1600 Amp, 50 KA -01 No (Incoming)(ii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel (iii) ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Outgoing)For existing DG panel(iv) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 2500 Amps duly moounted on porcelain insulators -01 Set (v) Digital amp meter 3 ph programmeable type with suitable2500 Amps -01 Set (vi)Digital volt meter 3 ph programmeable type with suitable0- 500 volts -01 Set (vii) LED phase indicator (RYB )-01 Set 74 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. 75 Under composion of following. (LT Panel No-2 upper chumathang)(i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming cum outgoing) (ii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1200 Amps duly moounted on porcelain insulators -01 Set(iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set(v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 76 Supply and install LT panel outdoor type weather & vermin proofsuitable for 3 phase 415 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and copper busbar of capacity not less than 1250 Amp insulated with PVC sleeves and coloured with (R,Y,B and Black) with angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following. (LT Panel No-3 upper chumathang additional pocket) 77 (i)ACB 415 V, 4 pole, 800 Amp, 50 KA -01 No (Incoming)(ii) MCCB 415 V, 4 pole, 200 Amp, 25 KA -1 No (Out Going), MCCB 415 V, 4 pole, 400 Amp, 36 KA -1 No (Out Going) MCCB 415 V, 4 pole, 100 Amp, 25 KA -1 No (Out Going)(iii) Bus bar chamber with and including aluminium strip (set 4 Nos) suitable for 1250 Amps duly moounted on porcelain insulators -01 Set (iv) Digital amp meter 3 ph programmeable type with suitable 800 Amps -01 Set (v)Digital volt meter 3 ph programmeable type with suitable 0-500 volts -01 Set (vi) LED phase indicator (RYB )-01 Set 78 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 300 Sqmm 3.5 core complete all as specified anddirected 79 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 240 Sqmm 3.5 core complete all as specified anddirected 80 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 185 Sqmm 3.5 core complete all as specified anddirected 81 Supply, laying, testing and commissioning of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 2 core complete all as specified anddirected 82 Supply and fixing of LED Street light of 70 Watt , IP66 power coated pressure die cast aluminium housing with high efficiency LED as lighting source and toughened glass complete all as specified anddirected 83 Supply and install LT panel box outdoor type weather & vermin proofsuitable for single phase 230 V made out of 3.15 mm thick MS sheet duly powder coatedand both sides openable with lockingarrangment and aluminium busbar of capacity not less than 100 Amp insulated with phase indicator incl angle iron frame for stand made out of40 x 40 x 6mmincludingfour legs grouted by using PCC (1:2:4) type B 1 with 20mm graded stone aggregate thimbling andcable entry box incl connection and necessary fixing arrangement complete all as specified anddirected by Engineer in Charge. Under composion of following.(For Street light)(i) MCB SPN 6-32 Amps, 230V, 10 KA -01 No (Incoming)(ii) MCB SP 6-10 Amps, 230V, 10 KA -02 No (outcoming)(iii) Bus bar chamber with and including aluminium strip ( 2 Nos) suitable for 100 Amps duly moounted on porcelain insulators -01 Set (iv) LED phase indicator (RYB )-01 Set 84 Supply and fixing GI bracket 1.2 m long made out of GI pipe 40mm dia mediam grade with necessary clamp for fixing nut and bolts and connection complete all as specified anddirected 85 Material and Labour for Steel tublar swaged poles erected truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to pole, B-118 final taper cap,bolts,nuts & screws, poles made out of ERW MS tubing conforming to IS 2713 Part-II. Type 410-SP-31 (09 m long) including drilling of holes of required size for fixing of cross arms, paintin g the exposed surfacs of pole with two coats of aluminium paint over a coat of two coats of zinc chrome3 primer and two coats of black bitumenous paint internally & portion embadded in concrete, making five black & white bands at lower portion of pole each 300 mm wide alternatley, and marking pole No. with black paint at suitable height complete all as specified and directed.Note :- Excavation and earth work, PCC in foundation shall be measured and paid for separetely. 86 Supply and fixing of 2.5 sqmm copper conductor cable for street light connection from junction box to street light at pole all as specified and directed by Engr-in-charge 87 Supply and fixing of junction box made out of PVC box with necessary clamps for fixing busbar with MCB SP 6 Amps and necessary connection from street light to junction box with 2.5 sqmm x 3C copper conductor cable complete all as specified anddirected 88 Material and Labour for Plain cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in bed to drain pipes including packing under and haunching completely surrounding pipes with concrete after they laid and tested for 150 mm bore NP 2 pipe, complete all as specified and directed. 89 Material and Labour forM&L for Reinforced concrete pipes,class NP2,dia 150 mmlaid and jointed complete with collars complete all as specified and directed. 90 Material and Labour for PCC 1:2:4 Type B1 using 20 mm garded stone agg as in coping including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. 91 Supply onlyliquid water proofing compoundcomplete all as specified and directed. 92 Material and Labour forTMT bars 10mm dia and over , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed not less than 0.9mm dia, or securing with clips, rungs, handles completeall as specified and directed. 93 Material and Labour forprecast cement concrete 1:2:4 type B-1 using 20mm graded crushed stone aggregates as in manhole coverslabsincluding necessary formworks set in cement mortar 1:4 complete all as specified and directed. 94 Material and Labour for cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in surface channel and inside drains of manhole complete all as specified and directed. 95 Material and Labour for Mild steel rungs and handle made to shape out of 16mm dia round barsconforming to Fe-290grade E-165including fixing/embedding in concrete /masonrypainted with two coats of bituminous paint complete all as specified and directed. 96 Extra forming fair finished drain or channel 30cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and directed. 97 Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landing and similar work not exc 200mm thick (horizontal or sloping) for flat fair finished surfaces complete all as specified and directed. 98 Material and Labour for construction of septic tank for 10 users designed to carry sewage and sewage water, excavation in any type of soil, PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates in foundation, precast cement concrete block masonry wall, RCC cover slab complete all as specified and directed and shown on drawing. 99 Material and Labour for construction of soakage well with excavation in any type of soil complete all as specifiedand directed and shown on drawing. 100 Material and Labour for MS work as in posts and struts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. 101 Supply only chain link MS galvanised fencing any size or type complete all as specified anddirectedNote : weight of chain link fencing shall be checked by BOO detailed by GE. 102 Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards rails straining bolts etc including provision of binding wire complete all as specified and directed. 103 Material and Labour for prepration of new or previously untreated steel surface & priming with red oxide primer and applying two coats of synthetic enamel paint of any description over 10cm width or girth not otherwise described complete all as specified and directed. 104 Material and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. 105 Material and Labour for Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 22.5cm longand diameter of neck 11 to 15mm complete all as specified and directed. 106 Material and Labour for construction of steel gate 5.5m wide and 3m high with RCC pillars including excavation and earth work and all other relevant works complete all as specified and directed. 107 Excavation over area not exc 1.5m deep and getting out in hard/dense soil complete all as specified and directed. 108 Excavation in trenches, n exc 1.5 mtr wide and n exc 1.5 mtr in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out inhard/dense soil. Complete all specifed and directed. 109 All as per Srl No. 94. above but exc 1.5 m or part there ofin depth beyond the first 1.5m complete all as specified anddirected 110 Excavation in post holes (or similar holes) each not exc 0.5 Cum getting out returning filling and ramming earth or broken rubble mixed with earth around in layers not exc 25cm watering and removing surplus soil to a distance not exc 50 and making good surface in hard/dense soil complete all as specified and directed. 111 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed . 112 Removing excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 113 Removing excavated rocks material from site n exc. 50 m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified anddirected
Contract Date: Jun 20, 2026 Contract Value : 6.14 Crore
Statutory Bodies & Commissions/Committees No of Bidders 9
19.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
Contract Date: Ref. Documents Contract Value : 9.78 Lakh
Boards / Undertakings / PSU No of Bidders 2
Andhra Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 21.89 Lakh
Boards / Undertakings / PSU No of Bidders 1
22.
Railways #10910841 AOC
Supply Of Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bore Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp)Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bore Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp),Set Of Items - (1) Supply, Installation, Testing And Commissioning Of A High- Accuracy, Full-Bor E Inline Electromagnetic Flow Meter Of 40 Mm Size, Suitable For Effluent Measurement In Effluent Treatment Plant (Etp), With Ip65- Rated Enclosure, Corrosion-Resistant Wetted Parts Compatible With Treated Effluents, I Ntegral Or Remote Digital Display, 4-20 Ma And Pulse Output, Modbus/Rs485 Communication, Dual Power Su Pply (220V Ac, 50 Hz/ Optional 24 Vdc), And Temperature Range 20 Degree C To 180 Degree C, Including Calibration And Configuration, Complete As Per Manufactures Specification And Direction Of Engineer-In-Cha Rge (Make: Aster/Upc Or Equivalent Approved, Model - Mag - Flow 650 Or Similar) - Qty. - 01 No. (2) Compl Ete Pvc Piping System With 3-Valve Bypass Arrangement, Comprising Two Pvc Ball Valves For Isolation, One Pvc Ball Valve For Bypass, And One Pvc Flow Control Valve, All Connected Through A High-Quality Pvc Header Of Suitable Diameter; Including All Associated Fittings Such As Tees, Crosses, Elbows, Reducers, Sockets, Plugs , Unions, Supports, Clamps, Hangers, Fasteners, And Anchoring Accessories; With Cutting, Chasing, And Restor Ation Of Walls/Floors To Original Condition Where Necessary; Scope Also Includes Supply And Installation Of Ele Ctrical Starter (As Per Equipment Rating), Along With Required Control Cabling, Terminations, And Interfacing, All Executed As Per Ga Drawing Approved By Rly. Authority., Qty. - 01 Lot. Detail Technical Specification As P Er Annexure Attached. [ Warranty Period: 30 Months After The Date Of Delivery ] ]
Contract Date: Apr 30, 2026 Contract Value : 1.26 Lakh
Government Departments No of Bidders 1
Contract Date: Apr 28, 2026 Contract Value : 10.68 Lakh
Local Bodies No of Bidders 2
25.
Drinking Water Supply and Sanitation #10896284 Price Bid
Tender for N.S. Item , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 2700 Lpm X 50.00 M (For B/Stn. No.12) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6900 Lpm X 45.00 M (For B/Stn. No.14) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 4100 Lpm X 45.00 M (For B/Stn. No.16) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set Forclear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 3500 Lpm X 45.00 M (For B/Stn. No.25) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (10 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (50 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (70 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (95 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (120 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (150 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (185 Sqmm Size) , Copper Cable: Supply, Erection, Testing And Commissioning Of Is Marked 3 Core Copper Cables, Solid Copper Conductor Up To 6Sqmm And Balance Stranded Copper, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Glavanised Wire For Cables Up To 10X1.5Sqmm, 8X2.5Sqmm, 2X10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip), Extruded Pvc Type St2 Outer Sheathed, /1100 V Grade As Per Is 7098 (Part 1) 1988 With Up To Date Amendments Along With All Accessories Like Thimble Lugs Etc For Motors As Per Entire Satisfaction Of Engineer-In-Charge Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (240 Sqmm Size) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.12) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 115 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.14) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 70 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.16) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.18) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.19) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 5 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.20) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 60 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.25) , Ht. Alluminium Cable: Supply Erection Testing Of Standard Make Xlpe 3 Core Ht / 11 Kv Grade Isi Marked Stranded Compact Circular Aluminium Conductor, Conductor Screen With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screening With Extruded Semi Conducting Compound In Combination With Copper Tape, Cores Laid Up, Innersheath Of Pvc, Galvanised Steel Flat Strip Armoured, And Overall Pvc Sheathed Cable Conforming To Is 7098 (Part-2) 2011 With Up To Date Amendments For Making Following Connection A) From G.O Switch To Metering Equipment . B) From Metering Equipment To Transformer Complete In All Respect. Make: Indian Cables Ltd./ Polycab / repair renovation Cables / Finolex / Havells Cables. (35 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (70 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (95 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (150 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (240 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (300 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (400 Sqmm Size) , Lt Cable Alluminium: Supply, Erection, Testing And Commissioning Of Is Marked 3.5 Core Cables, Solid Aluminum Conductor Up To 10Sqmm And Balance Stranded Conductor, Xlpe Insulated, Cores Laid Up, Pvc Inner Sheathed, Armoured (Aluminium Wire For Single Core Up To 70Sqmm And Balance Aluminium Strip, Glavanised Wire For Cables Up To2x10sqmm, 3X10sqmm, 4X6sqmm And Balance All Galvanized Steel Strip) Extruded Pvc Type St2 Outer Sheathed, 650/1100V Grade As Per Is7098 (Part-1) 1988 With Up To Date Amendments Along With All Accessories Complete In All Respect. Make: Indian Cables Ltd./ Finolex / Havells / Polycab / repair renovation Cables. (500 Sqmm Size) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 35 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.22) , Providing And Laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) Cast Iron, Class B (Is 1536) Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Etc Up To The Site Of Work. 350 Mm Nominal Diameter , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 2800 Lpm X 50.00 M (At Mbs For Zone -2) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 40 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For Zone-1) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 55 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For Zone-2) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6900 Lpm X 50.00 M (For B/Stn. No.10) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 130 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.10) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 9500 Lpm X 45.00 M (For B/Stn. No.13) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 160 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.13) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5900 Lpm X 45.00 M (For B/Stn. No.17) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 100 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.17) , Providing And Fixing Of Ci Sluice Valves Conform To Is1 4846 / Din 3352,With Length Over Flanges As Per Pdoralt1ofis14846 Corresponding To Bsen - 558/Iso5752 Basic Series 3 And15 Respectively Including Labour, Material, Joints. Make:Ivc / Vag / Kirloskar Complete In All Respect As Per Specifications Mentioned In Dnit (700 Mm I/D) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 10 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.15) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 120 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At B/Stn. No.13 For Existing Pumping Machinery) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5100 Lpm X 50.00 M (At Mbs-1 Zone) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 95 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs-1 Zone) , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 100 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 150 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 200 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 250 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 300 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 350 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 400 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 450 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 500 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 600 Mm Nominal Diameter , Providing, Fixing, Lointing, Testing Of Mechanical Joints Complete With Rubber Gaskit, Galvanized Nuts And Bolts Including Labor, Tranportaion Ets Up To The Site. 700 Mm Nominal Diameter , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 8500 Lpm X 35.00 M (At Mbs-1 For B/Stn.) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 112.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs-1 For B/Stn.) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 5500 Lpm X 30.00 M (At Mbs For B/Stn.) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 62.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (At Mbs For B/Stn.) , Supply Erection Testing Of Reputed Make Led Light 100 Wats With Fittings And Accessories Complete In All Respects. (Led= 5 No.) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 6000 Lpm X 50.00 M (For B/Stn. No.9) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 115 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.9) , Clear Water Pump: Supplying, Erection, Testing And Commissioning Of Horizontal Motor Pumping Set For Clear Water Having Head As Per The Indicated Requirements Of Discharge In Lpm And Power Capacity In Bhp As Per Is Marked 4600 Lpm X 45.00 M (For B/Stn. No.23) , Design, Supply, Installation And Testing Of Vfd Along With Distribution Panel In Enclosure For Motor Rating Of 77.50 Hp. Enclosure Shall Be Ip54. The Panel Shall Be Equipped With Mccb Tp With Suitable Rating, Spreader Link Tp, Extended Rotary Handle, Volt Meter Digital, Volt Selector Switch, annual periodical maintenance Meter, annual periodical maintenance Selector Switch, C.T With Suitable Rating, Control Mcb Sp With Suitable Rating, Pla Relay, Pushbutton Red Plus Green With Element, Indicator On/Off, Aluminium Bus Bar/Suitable Rating Power And Control Wiring Labour And Margin, Fabrication With Minimum Sheet Thickness Of 2 Mm For Load Bearing And Non-Load Bearing Side. Vfd Should Be Capable Of Protecting Motor From High And Low Voltage And Earth Fault As Well. Vfd Should Restrict Harmonics Up To 35% Vfd Should Be Capable Of Providing Starting Torque Up To 200% While Starting Motor. It Should Have Class 3C3 (Avg)Conformal Coating So That Components Are Safe From Dust And Moisture. Communication -Built-In Rs485 Modbus Rtu, Ambient Temperature -Heavy Duty: -10 ~ 50 Deg C Normal Duty: -10 ~ 40 Deg C, Pcb Protection Conformal Coating Complying To Iec 60721-3-3 Class 3C3, Application Humidity Below Relative Humidity 95% Rh (No Condensation) Altitude 0 To 1,000 M Without Deration 1,001 To 4,000 M With Deration Of 1% Per Rise In 100 M, Vibration Up To 9.8 M/Sec2 (1.0 G), Global Compliance Ce, Ul, Rohs, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% At 0.5Hz In Sensorless Vector Control And 150% At 3Hz In V/F, Frequency Control Range 0 To 400Hz In V/F, 0 To 300Hz In Sensorless 1, 0 To 120Hz In Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). Complete With All Other Accessories As Required. (For B/Stn. No.23) , Less Credit For Old Good Bricks 20.77 X 60% = 12.46 @ 480 Brick Per Cum = 5981 , Less Credit For Old Bricks Bats @ 40% ( Cum ) Total 20.77 X 40% = 8.31 , Less Credit For Ms Railing @ 40% ( Cum ) Total 11 X 50 = 550 Kg , Providing And Fixing Of 15 Mm Nominal Diameter Water Meter As Per Is 779:1994 Inferential Type Dry Dial, Mechanical Driven, Non Megnatic Drive, Straight Reading Cyclometer Type, 7-Inline Consequent Digits With One Centre Point For Easy Reading Complete In All Respect. , (I) Designing, P And F, Commissioning And Testing Of Vacuum- Operated Automatic Switchover Gas Chlorination System With 1 Working Chlorinator Plus 1 Standby Chlorinator Compatible With The Existing Gas Chlorination System With Three Months Trial Run And One Year Defect Liability Period. (Ii) Designing, P And F, Commissioning And Testing Of Chlorine Gas Dry Scrubber Consisting Of Support Structures, Ductwork Of Scrubber, Blower, Dry Scrubbing Tank, Dry Scrubbing Media, Necessary Piping, Motors, Controls, Exhaust Stack And Essential Accessories With Three Months Trial Run And One Year Defect Liability Period. Pandf Of Prefab Porta Cabin Of Size 1.83 M. X 1.83 M. And Height 2.3 M. With One Side Slope Design With 50 Mm Puf Wall Panels With Pre Painted Galvanized Sheet And 20/60 Mm Corrugated Puf Roof Panels With Pre Painted Galvanized Sheet With Door, Windows Etc. Complete In All Respect. (Iii) Designing, Pand F, Commissioning And Testing Of Auto-Shut Off Valve With Three Months Trial Run And One Year Defect Liability Period. (Iv) P And F Of Dual Gas Cylinder Duly Certified And Approved By Bis And By Explosive Department Of Govt. Of India, Nagpur Of 100 Kg Capacity Cylinder As Per Is 3196 Part -Iv. (V) Providing, Fixing, Installation, Commissioning And Testing Of Chlorine Leak Detector With Alarm/Hooter. (As Per Technical Specifications Of Gaseous Chlorination System As Per Letter Of Eic, Phed, Pkl. Memo No. 23070-23142-Phe/Mont. Dated 28/02/2024 (Copy Attached). (1 For B/Stn. No.9 , 1 For B/Stn. No.10 , 1 For B/Stn. No.11 , 1 For B/Stn. No.12 , 1 For B/Stn. No.14 , 1 For B/Stn. No.16 , 1 For B/Stn. No.17 , 1 For B/Stn. No.21 , 1 For B/Stn. No.22 , 1 For B/Stn. No.23 , 1 For B/Stn. No.25 , 1 For Mbs-1 , 1 For Mbs-2) , Operation And Maintenance For Complete Scope Of Work Mentioned In Dnit (Disinfection Material Will Be Supplied By Phed) As Per Schedule-Iv For A Period Of 5 Year After 12 MonthS During Defect Liability Period And 3 Months Trial Run Period Will Be Charged To The annual maintenance Estimate Complete In All Respect As Per Approved Nit. (I) Operation And Maintenance Defect Liability Period (Operation Only) After 3 Months Trial Run Period. , (Ii) Operation And Maintenance During 1St Year After Defect Liability Period. , (Iii) Operation And Maintenance During 2Nd Year. , (Iv) Operation And Maintenance During 3Rd Year. , (V) Operation And Maintenance During 4Th Year. , (V) Operation And Maintenance During 5Th Year. , Item Description , Hsr Item
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
29.
Educational and Research Institute #10754595 Price Bid
Precision Air Conditioning Units Dx Type Units With Ec Fan Motors And Digital Scroll Compressors Precision Air Conditioning Units Dx Type Units With Ec Fan Motors And Digital Scroll Compressors , Hvac Supply, Loading Unloading Lifting, Installation, Commissioning And Testing Of High Precision Package Type Dx Air Cooled Unit With Top / Side Discharge, Air Cooled Condenser With Fan And Motor, With Filter Section, Ec Motor With Plug Type Axial Fan, Air Cooled Condenser Coil With Anti Corrosive Paint, Twin Scroll Compressor Motor Set With R 407C / R 410A Refrigerant, Condensate Drain Pan, In Built Data Logger, Power Monitor Relay, Liquid Receiver, Thermostatic Expansion Valve, Vibration Absorber For Compressor, Hp / Lp Cutouts, Water Detector Sensor, Fire Tripping Relay, In Built Auto Sequencing Program, Micro Processor Panel, Digital Display, Programmable Control And Recording Unit, Alpha Numeric Display, Function Keys, Cursor Keys, Free Programmable Keys, Multi Color Leds, Humidifier, Heater, Battery Back Up Supply At 24 V / 50 Cycles / Sec Etc. The Unit Shall Be Suitable For Operation On 415 V, 3 Phase Supply. The Display Panel Shall Display Date, Time, Actual & Set Values, Fault Timing Values, . Controls Shall Be Suitable For Linking To Building Automation System Modbus Open Protocol. , Capacity 28 Kw ( 8 Tr ) Temperaure 20 + / - 0.8 Deg C, Relaitve Humidity 50% + / - 5% Rh. , Ms Painted Pedestal For Both Outdoor & Indoor Units , Supply And Laying Of 18 / 19G Copper Refrigeration Piping With All Fittings Should Be Long Bend ( No Elbow ) With Proper Insulations, Supports, Nylon Tape Wrappingetc , 34.9 Mm Copper Pipe , 22.2 Mm Copper Pipe , Supply And Laying Of Copper Conductor Cable From Main Panel To Control Panel As Required. , Supply And Laying Of Copper Conductor Power Cable Between Indoor And Outdoor As Required , Supply And Laying Of Copper Conductor Communication Cable Between Units For Sequencing As Required. , Supply And Laying Of Gi Ducting, Complete With Anchor Fasteners And Gi Supports, Bracings As Required, Nut, Bolt & Gasket Etc , 22 G Ducting: , Supply And Installation Of Powder Coated Aluminium Supply Air Grills And Return Air Outlets: , Supply Air Grille With Damper , Return Air Grille With Motorized Damper , Supply And Installation Of Powder Coated Aluminium Fresh Air Damper And Cowl: , Supply And Installation Of Fusible Link Type Fire Damper: Frames 18 G Aluminium Louvres 20 G Aluminium , Supply And Laying Of Fresh Water And Drain Piping For The Units With Nitrile Rubber Insulation , With Pvc Piping Of 4 Kg Rating, Complete With Bends, Fittings And Supports , 50 Nb , 25 Nb ( Drain ) , Supply And Fixing Of Perforated Cable Traywith Cover With Horizontal & Vertical Bends, Reducers, Tees, Cross Over , Suitable Supports And Brackets And Other Accessories As Required Confirming To Iec-61537. The Tray Shall Be Galvanized For Corrosion Protection Confirming To Din En 10346 / Iso 1461 .The Trays Should Be Tested For A Safe Working Load Of 150 Kgs With A Span Distance Of 1.5 Meters And The Deflection Should Be Within The Limits As Per Standard. The Safety Factor Shall Be 1.7 Times Of The Safe Working Load. The Perforated Tray Shall Be Supplied With The Standard Length Of 3 Mtr . Incl Cover. The Rate Shall Inclusive Of Necessary Theaded Rods, Nuts & Bolts, Making Clamp In The Z Perlin / Truss, Cable Tray Clamps Etc, ( 8 Mm Threaded Rod Shall Be Providedat Every Alternative Purlin Appx. 2 Mtr Length ) , 300 X 50Mm X1.6Mm , 100 X 50Mm X1.6Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
31.
Educational and Research Institute #10707338 Price Bid
Supply Of Machmilling , Supply Of Mechanical Departmentcomputer Integrated Manufacturing Laboratory Items , Cnc Mill Machine With Servo Motors 1. Controller Pc Based System With Plc Control And Emulation Of Fanuc, Siemens, Heidehein And Traub Controller 2. Traverse X, Axis 300 Mm X Axis Minimum Traverse Y Axis 200 Mm Y Axis Minimum Traverse Z Axis 250 Mm Z Axis Minimum 3. Table Size : Length X Width 600 X 225 Mm Minimum 4. Axis Control Simultaneous Three Axis Control With Servodrives & Servomotors And Optional 4Th Axis Indexing Facility Axes Motors Ac Servo Motors With Digital Feedback Servo Motor Make Siemens / Fanuc 5.Maximum Table Load 120 Kg. Min. 6. Tool Changer Automatic Tool Changer Through Software No. Of Tools 8 Minimum Atc Actuation Pneumatic With Pneumatic Compressor Tool Dimensions : As Per Iso 30 Standard 7. Automatic Tool Changer Automatic 8 Station Tool Changer To Be Operated By Pneumatic Powerpack (Compressor To Be Provided By Manufacturer) Main Spindle Motor – Power 2 Horse Power Min. 8. Main Spindle Motor – Speed 150 – 300 Rpm 9. Resolution X Axis 1 Micron Resolution Y Axis 1 Micron Resolution Z Axis 1 Micron 10. Rapid Traverse 5,000 Mm Per Minute Feed Rate 1 To 2000 Mm/Min 11. Cutting Force X / Y / Z 900 / 900/ 1200 N 12. Position Accuracy X / Y / Z * 10 Micron Maximum 13. Lubrication System Main Spindle, Guide Ways And Other Areas Automatic Lubrication System To Be Operated Through Software 14. Safety Devices Needed Fully Enclosed Working Area. Limit Switches For X And Z Axes Emergency Off. 15. Control 24 V Dc Signal Voltage. With Surge Protection For Sudden On / Off Of Electrical Supply Or Surge Voltage Or Current 16. Type Of Control System Plc Controller Of Servo Drives With Modbus Communication Facility To Pc. Controller Should Be Able To Emulate Fanuc / Siemens / Heidenhein Controllers 17. Complete Training Module It Must Have Complete Cad-Cam Solution & Dnc Facility 1) 3D Model & 2D Facility 2) Cad Program From Industry Should Be Machined On Trainer 18. Cad Software Linking Facility Cad Model Linking Facilty From Autocad, Unigraphics, Proe, Catia Should Be Able To Import 19. Co-Ordinate System Cartesian Coordinate As Well As Polar Co-Ordinate Programming Facility To Be Provided. Industrial Grade Mop Industrial Grade Mop For User Interface With Online Reset , Axis Drives Axis Movements With Siemens / Fanuc / Mitsubishi Servo Motor And Drives With Encoder Above 10000 Ppr 20. Main Supply Three Phase Supply, 415V Ac 21. Main Spindle Motor 2Hp Main Spindle Controller Infinite Variable Speed Control With Vfd Vfd Make Delta / Siemens 22. Machine Link Rs-232 Link/ Rs-485 And Usb Cable From Pc To Machine And Ethernet Communication 23.Software Programming And Operating Software And Manuals With Courseware & Project Book 24. Coolant Flood Coolant System Of Capacity Of 4 Liters 25. Guard Totally Enclosed High Visibility Guard 26. Safety System Emergency Stop Button Axes Limit Switches 27. Tool Path Tool Path Graphics To Verify Program Prior To Machining 28. Job Scaling Facility And Canned Cycles Required Control Software Features: 29. Programming Format Programming Format With Siemens And Fanuc And Iso Codes Pc Based Software Window Based Pc Software Which Should Work On Window –Xp Platform. It Must Provide Online 3D Graphics 31. Programming Facilities Mdi Programming Facilities 32. Interpolation Full Circular And Linear Interpolation 33. Programming Units Imperil / Metric Programming 34. Subprogram Subprogram With Repeat Facility / Program Call 35. Machine Stop Manual And Programmable Machine Stops 36. Software Requirements For Programming Datum Shift Program Verification Via Dry Run Facility Tool And Program Offset Can Be Saved To The Disc. Program Verification Via Dry Run Facility. Full G And M Code Listing With Context Sensitive Help. Single Block Or Auto Execution Block Skip Function Block Search Facility 2D And 3D Simulation: Dynamic Zooming, Color Coding Of Tools, Different Move Types-Rapid /Linear/Arc Distinguished By Colours, User Defined Tool Shapes And Sectional Views Comprehensive Tool-Path Graphics Including 2D &3D Color Simulation, Tool-Path Plot And Machining Process Simulation With Tool Animation Directory Listing Program Merging Facility Automatic Error Checking With Message Continuous And Incremental Jog Modes With Variable Feed Rates Screen Axis Display For Distance To Go Values. Full Edit Mode Allowing Alters, Delete, Insert. Cycle Start/Hold Programmable Dwell Over Travel Limits And Emergency Stop Programmable Spindle Speed: 150-3000Rpm Programmable Federate:0-600Mm/Min Constant Surface Feed Simultaneous Controlled X And Z Axes Diameter / Radius Programming Internal/External Screw Cutting Roughing And Finishing Cycles Canned Turning Cycles Tool Offsets For 16 Tools Incremental Tool Wear Compensation Tool Nose Radius Compensation Interface With Cad/Cam Software Built In Virtual Micrometer Password Protected Machine Parameters 37. Pc Configuration: Multi Media Pc - Processor: Intel Duel Core 3 Ghz, With Ht Technology, System Bus 2Gb Fsb Cache: Intel Processor 2.8 To 3.6 With 1Mb L2 Cache Hdd: Seagate 400Gb, 7200 Rpm Graphic Card Modbus Communication Facility Monitor: 15” Color Monitor Mouse: Optical Scroll Mouse Wireless Keyboard: Wireless Drive Cd Rom: 52X32x52x Ether-Net Card: Integrated Drives For All The Necessary Hardware 38. Cad-Cam Software Cad Model Import Facility And Automatic Code Generation Software To Be Provided Alongwith Machine. Modeling And Code Generation Software Has To Be Provided 39. Training& Manual The Successful Tenderer Shall Provide Sufficient On The Job Training At The Tender’S Own Cost To At Least Two (2) Nominated Teachers For Each School In System Operations And Routine Maintenance Of The Equipment. 1)User Manual, 2) Operating Manual, 3) Maintainnace Manual 4) Training Viedo Cd 40. Miscellaneous Three Days On Job Training At Institute Operating Instruction & Maintenance Manual, Electric Circuit Diagrams: 2 Sets Courseware & Project Book: 01 Set Set Of Maintenance Tools & Necessary Spare Parts. 01 Set Foundation, Installation & Commissioning At Site Warranty: One Year => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
32.
Educational and Research Institute #10687064 Price Bid
Construction Of Screen House 156 Sqmtr-02 Nos. Construction Of Screen House 156 Sqmtr-02 Nos. , Size ( 12 Mtr. 13 Mtr. Side Height 3.5 Mtr. Center Height 5 Mtr ) , Structure ( Multi-Span, Dome Shaped, Welded As Well As Dismantlable ( With Nut-Bolts And Clamps ) , Gi Pipes ( Round Gi, 60Mm, 50Mm, 24Mm, 50X25mm Pipe Thickmness-2.2 / 2.0Mm Gi Pipe Hot Dip Galvanized ) , Galvanization Quality ( All Pipe Should Be Deep Hot Galvanized. Corrosion Resistant And Isi Mark ) , Poly Film Cladding Of Roof ( 200Micron Thick Uv Stabilized ( Garware / Ginegar Ir Make ) ) , Fixing Of Sheet ( ?The Complete Polyfilm To Be Fixed With G.I. Profile & Locking Spring ? Profile To Be Fixed With Self- Drilling Steel Screws , Side Ventilation ( Side Ventilation All Four Sides 3M Above Skirting / Side Wall Of Stainless Steel ( 55 ) Insect Net Of 304Grade, 40 Mesh, Ss Mesh Fixed With Aluminium Strips, Manual Rolling With Gear System , Gutter ( Trapezoidal, Gi , With Drainage Connection ) , Gutter / Side Height ( 3.5M From Ground Level ( Includes Skirt Wall ) , Ridge Height / Centre Height ( 5.0M From Ground Level ( Includes Skirt Wall ) , Shading System ( 50% Shade Factor , Uv Stabilized White Colour , Mono-Tape ( Make Garware / Netion ) , Provided Inside The Structure With Manually Folding-Spreading System ) , Side Rolling ( 4 Sides, Manual Rolling With Gear System, Of Polyfilm Of Garware Ir / Ginegar Make ) , Buffer Room ( 2Mx1.5M With Double Door Entry .Doors Made Of Gi Pipes And Cladded With Polyfilm Buffer Room Will Have All The Switches. / Mcbs , Misting System ( 54 No. Four- Way Foggers ( 22.5Lph ) , Laterals , Pump, Filters, Etc. Netafim / Automat Make, With Pvc Fittings, 1.5 Hp Pump ( Crompton / Arise ) Make. 500Its Water Tank Of Sintex / Equivalent Make ) , Drip Irrigation System ( 16 Lines Of 16 Mm Pipe With Inline Dripper At 30Cm Spacing ( Netafim / John Deere Make ) .Water Pump Of 1.5Hp ( Crompton / Arise ) Make. Filter- Automat / Netafim Make 1000 Lts Water Tank Of Sintex / Equivalent Make With Complete Plumbingof Pvcpipe ( Prince / Supreme / Isi Marked Make ) , Electricals ( Copper Cables, Isi Marked For Pump, Mcb, Main Switch , Etc. ) , Civil Work ( Skirt Wall Of Brick / Local Stone, 9 Inches Thick, 1.5Ft Below Ground And1.5Ft Above Ground ) , Data Logger ( Temperature & Humidity Data Logger Model Number : Mta L 12 Data Logger Feature ( A ) 2 Channel ( B ) 0-5 V Input Ports ( C ) Rs 232 / Rs485 / Modbus & Gprs Communication Port ( D ) Set Point Feature In All Channel ( E ) 20X4 Lcd ( F ) Gui Software For Online Server & Mobile App ( G ) Gsm Facility Can Fetch Receive Data On Mobile Phone ( H ) 8 Gb Memory Card Storage ( I ) Direct Interface To Pc ( J ) Single Relay For Controlling The Application ( K ) Battery Operated ( Back Up Up To 6-8 Hour ) Wireless Interfacing Method ( A ) Modbus ( B ) Etherner Wireless Interfacing Method ( A ) Gsm / Gprs ( B ) Wifi Sensor Specification Temperature Sensor Range 0? C To 70? C Accuracy + / - 0.5?C Humidity Sensor Range 0 To 100% Accuracy + / - 3%
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 4
Arunachal Pradesh View Result →
33.
Power #10656217 Price Bid
Augmentation / Renovation And Modernization Of 33 / 11 Kv Receiving Station Sunjwan From 2X1.5 Mva To 2X3.15 Mva Along With, Erection Of New 33 Kv Line ( 2Nd Source ) From 33 / 11 Kv, 3X10 Mva, Receiving Station Channi Himmat To Receiving Station Sunjwan, Stabilization / Strengthening Of Existing 33 Kv Line ( 1St Source ) And Other Allied Works Relating To Receving Station Mes Sunjwan, Jammu On Turnkey Basis- 1 Substation Main Equipment 2 33 Kv Transformer Bay & Single Bus 33 Kv Line Bay 3 33 Kv Vcb ( 36 Kv, 1250A, 26.2 Ka, Outdoor Type ) 4 33 Kv Isolator Without Earthing Blade ( 36Kv, 1250A, Outdoor, 3 Poles, 25 Ka ) 5 33 Kv Current Transformer ( 33 Kv, 1F, Multi Ratio Multi Core, Outdoor ) ( 1 No. Per F ) 6 33 Kv Voltage Transformer ( 33 Kv / 110 V, 1F, Multi-Core, Outdoor ) , ( 1No. Per F ) 7 33 Kv Lightening Arrestors ( 30 Kv, 10Ka, Station Class, Zno, Polymer ) Gap Less 8 33 Kv Polymer Post Insulator36kv, 170Kv Impulse, Creepage Distance 1224M 9 33Kv C&R Panel Along Witho / C, E / F Relays, Diffrential Relay, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps With Rs-485 Port, Dlms Compliant With Rs-485 Port ( For Power Transformers ) 10 33Kv C&R Panel Along Witho / C, E / F Relays, Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps With Rs-485 Port, Dlms Compliant With Rs-485 Port 11 Steel Structures 12 Galvanised Steel Structures 13 Galvanised Nuts & Bolts 14 Conductor And Hardware 15 200 Mm² Acsr Panther Conductor 16 T Clamps 17 Tension Fitting Suitable For 200 Mm Sq Conductor. 18 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 19 Earth Wire 7 / 3.15 Mm Sq. 20 Gi Flat For Earthing 50X6mm & 25X3 Mm 21 3.15 Mva , 33 / 11 Kv Power Transformer 22 33 / 11Kv, 3.15 Mva Onan, Copper Wound, Out-Door Type, Conventional Power Transformer, Oil Filled With Oltc And All Accessories Including Ht And Lt Terminal Connections 23 Power Control Cables And Accessories 24 12 Core, 2.5 Mm Sq. 25 6 Core, 2.5 Mm Sq. 26 4 Core, 2.5 Mm Sq. 27 2 Core, 2.5 Mm Sq. 28 Lugs, Ferrules Etc. 29 Laying Of 33 Kv Line ( Approximately 1.9 Km ) 30 13 Mtr. Long St Poles ( St-410Sp69 ) 31 G.I Channel ( 100X50x6 ) Mm Sq, G.I Angle ( 65X65x6 ) Mm, G.I Angle ( 50X50x6 ) Mm Sq. Sq., G.I Flat ( 50X6 ) Mm Sq. 32 200 Mm2acsr Panther Conductor 33 P.G. Clamp For 200 Mm2 Acsr Panther Conductor 34 33 Kv Pin Insulators Polymer Type ( 10Kn ) 35 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 36 Tension Fitting Suitable For 200 Mm Sq Conductor. 37 Galvanised Nuts And Bolts With Washers 38 33 Kv Danger Plates With Clamps 39 Anti-Climbing Device With Clamps 40 Earthing Complete ( Gi Pipe 40 Mm Or Gi Rod 20 Mm, 2.5 Mtr Long With Gi Strip ) 41 33 Kv Isolatorwithout Earthing Blade 42 Red Oxide Paint 43 Aluminum Paint. 44 Cement Bottoming ( 1:2:4 Mix As Per Rec Standards, 6 Cum / Pole ) 45 Aluminium Jointing Sleeevs 46 Insertion Of 11 Mtr St Poles In Existing 33Kv Line 47 11 Mtr. Long St Poles ( St-410Sp56 ) 48 G.I Channel ( 100X50x6 ) Mm Sq, G.I Angle ( 65X65x6 ) Mm, G.I Angle ( 50X50x6 ) Mm Sq. Sq., G.I Flat ( 50X6 ) Mm Sq. 49 200 Mm2acsr Panther Conductor 50 P.G. Clamp For 200 Mm2 Acsr Panther Conductor 51 33 Kv Pin Insulators Polymer Type ( 10Kn ) 52 33 Kv Polymer Composite Disc Insulators 36 Kv, Min Falling Load 70 Kn, Lightening Impulse 170 Kv Positive And 180 Kv Negative, Creepage Distance 900 Mm. 53 Tension Fitting Suitable For 200 Mm Sq Conductor. 54 Galvanised Nuts And Bolts With Washers 55 33 Kv Danger Plates With Clamps 56 Anti-Climbing Device With Clamps 57 Earthing Complete ( Gi Pipe 40 Mm Or Gi Rod 20 Mm, 2.5 Mtr Long With Gi Strip ) 58 Red Oxide Paint 59 Aluminum Paint. 60 Cement Bottoming ( 1:2:4 Mix As Per Rec Standards, 6 Cum / Pole ) 61 Aluminium Jointing Sleeevs 62 Guard Netting Of 33 Kv Lines 63 Guys For 33 Kv Lines 64 Galvanised Stay Set With 50X8 Mm Stay Clamp, Guy Insulators ( 2 Nos ) , Anchor Plate ( 300X300x8mm ) , Nut Bolts, 2 Nos Turn Buckles, 1.8 M Long, 20 Mm Diameter Solid Gs Stay Rod & 7 / 4.00 Mm Dia Gi Standard Wire Complete. 65 Common Miscellaneous Works 66 Development Of Land 67 Chain Link Fencing Of 33Kv Yard Of Substation By Way Of Mass Concreting In Foundations And Chain Link Fencing Of 6Ft. Height 68 33 / 11Kv Transformer Foundation 69 33Kv Equipment Foundation ( Breakers, Cts / Pts, Isolators, Las ) 70 Earthing Mat ( Gi Flat 50Mm X 8Mm ) 71 33Kv Yard Concreting / Metalling And Laying Of Gravels 20Mm ( Complete Bays ) 72 Yard Lightening ( Complete ) With 4 No. 9 Mtr Long St Poles ( St-410 ) , Sp-33, Fitted With 2 No. 60 W Led Lights On Each Pole, Complete With Control Gear Box, Earthing And Bottoming Of Poles. 73 Rcc Cable Trench ( 1:2:4 ) For Laying Of 11 Kv Xlpe Power Cables And Control Cables From Various Equipments To Control Room & From Control Room To Outgoing Structures Alongwith Rcc Duct Covers. 74 Earthing Electrode ( 3M Long 40Mm Dia Gi Pipe ) Through Gi Strip 75 Common Miscellaneous Equipments 33 / 11Kv Substations 76 A ) . Battery Bank 30 V, 100 Ah , Of 15 No. Cells Of 2 V Each, Sealed Maintenance Free Vrla Type, High Impact Polyprophelenecopolymer Container, Flame Retardant. B ) . 30V, 100 Ah , Float-Cum-Boost Charger With Full Wave Rectification For 220 V, 1Phase, 50 Hz Ac Input Supply . 77 Distribution Panel ( 30 V, Dc ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43 For 2 No Battery Incoming Supply With 2 No 63 Amps Dp Mcbs For Incoming Supply Doublebusbar Of Adequate Size, 12 No Dp Dc Mcb ( 0-32A ) Including Indication Lamps And Cables And Other Accessories 78 Distribution Panel ( 415 V, Ac ) Made Of Crca Thickness Not Less Than 2Mm. Powder Coated, Degree Of Protection Ip43. 200 Amps Switch Fuse Disconnector For Incoming Supply And 5 No Tpn McbS ( 16-125 Amps ) And 5 No Dp Mcbs ( 0-32A ) , Rectangular Busbar Suitable For 200 Amps Continuous Supply Including Indication Lamps And Cables And Other Accessories 79 Rubber Mat 1Mx2m 3 Mm Thick For 33 Kv 80 Fire Extingiusherco2type Of 4.5 Kg Capacity For Control Room 81 3Sand Bucket Fire Extingiusher 82 Helmet 83 Rubber Gloves For 33 Kv Level 84 Rubber Gloves For 11Kv Level 85 Safety Belt 86 Safety Shoes 87 Hv Detectors For 33 Kv 88 Earthing Rod ( Set Of 3 Rods ) 89 Rmu Along With Out Going Cable 90 33 Kv Ring Main Unit : 3 Way Out Poor Type Rmu, Sf6 Insulated, Extensible Type, At 33 Kv System Voltage And Breaking Capacity 25 Ka For One Second, With Sf6 Circuit Breaker / Vcb Self Powered With O / C+ E / F Relay System Comprsing Of A ) One Nos 33 Kv, 630 Amp. Motorized Isolators Including Earthing Switches With Making Capacity 62.5 Ka, Having Mechnical On / Offb ) Two Nos 33 Kv, 200 Amp Motorized, Spring Operated, Circuit Breakers With Earthing Switchesc ) Cu Bus-Bar Of 630 Amp. Ratingd ) One No Numerical Aux. Self Powered Relay Having Non Directional O / C And E / F Protection ( For Each Circuit Breaker Feeder ) , Relay Should Have Minimum 7-Di & 8-Do. The Relay Shall Also Interface Via An Rs 232 / 485 Port In Orde O Send, As A Minimum, Real Time Readings Using The Modbus Protocol.E ) Incoming Isolators Shall Have Fpi With Electrical Reset Contact / Facility.F ) All Necessary Potential-Free Contacts For Indications Relevent To Rmu Monitoring And Control.G ) Capacitor Voltage Dividers Serving Live-Line Cable Indicators In Each Breaker & Isolator. 91 33 Kv 3 Phase Indoor Terminating Kit To Be Used With Cables-185Mm Sq. 92 33 Kv 3 Phase Out Door Terminating Kit To Be Used With Cables-185Mm Sq. 93 Cable Route Markers 94 Excavation In Any Type Of Soil Including Hard Laterit Soil 95 Refilling Of Excavated Soil 96 Sand For Cushioning Of The Cables In The Trench 97 Cement Tiles Of Size 300 Mm Lengthx 250 Mm Widthx 37 Mm Thick As A Protective Cover For Underground Cables 98 Earthing Of Rmu- Excavation Of Earth Pit Of Dia 650 Mm & Depth 3000 Mm, Installation Of Earthing Pipe Of 40 Mm Nominal Bore & 4 Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239. Gi Strip For Neutral Earthing Of Size 75 Mmx10mm & 50 Mm X 6 Mm For Connection Of Rmu Body As Per Is 2629 / 85, Gi Nuts And Bolts, Refilled With Earth Enhancement Materials And Earth Chamber Made Of Brick Masonary With Rcc Slab Cover. 99 Cement Concrete 1:2:4 ( 1 Cement, 2 Coarse Sand, 4 Graded Graniticor Basaltic Stoe Aggregated 40 M Nominal Size Of Foundation ) 100 Centering And Shuttering Including Struttings, Propping Etc. & Removal Of Form Work 101 15 Mm Cement Plaster 1:4 For Foundations. 102 Wire Mesh Boundary Fencing Around The Rmu 103 33 Kv, 3 Core Xlpe Cable Armoured, 185 Mm2 104 Installation Of Capacitor Bank 105 12 Kv, 1.2 Mvar, Capacitor Bank With Vcb Panel With Complete Arrangement For Conection With 11 Kv Incomer Panel , Series Reactor, Isolator, Rvt, Surge Arrestors, Ht Cable With Termination Kits, Control Cables, Crca Cubicle Panel Etc With Structure, Foundation & Accessories. 106 33 Kv Ct / Pt 107 33Kv Ct / Pt Combined Unit, With Ct Ratio 100 / 5 & Ptr 33 Kv / 110 V / V3 , 3-Phase, 50 Hz, Onan Cooled, Outdoor Type. The Combined Unit, Cts And Pts Shall Be As Per Below Specifications.The Rated Burden Of Ct Shall Be 7 Vathe Rated Burden Of Pt Shall Be 20Va Per Phase With Proper Colour Coded Identification. Pts Shall Be Of Uniform Insulating And One Minute Power Frequency Dry Withstand Voltage 70Kv 108 Metering Cubicle For 3Phase 4 Wire Metering System Suitable For 3 Phase, Ht, Tri-Vector Meter With Sealing And Locking Facility Made Of Ms Sheet Steel Thickness Not Less Than 2Mm Duly Power Coat Painted Suitable For Indoor As Well As Outdoor As Per The Site Requirement. The Cubicle Shall Be Painted Through 7-Tank Process. The External Dimensions Should Be Adequate. Provided With Synthetic Or Semi Synthetic Gasket Firmly Glued To The Surface, Dust, Weather Andvermin Proof And Shall Comply Degree Of Protection Ip 65 Both The Chambers Having One Sided Hinged Door Arrangements. The Panel Shall Be Provided With Two No Ms Channels Of Size 100 X 50 Mm On The Front And Rear Sides Duly Welded And 4 No Of Lifting Hooks. It Should Be Possible To Take Meter Reading Manually, Through Cmri And Computer Without Opening Door. Including Supply And Fixing Of 75Mm Gi Pipe Between Ct / Pt Combined Unit And Metering Cubicle For Ct / Pt Wiring To Tri-Vector Meter. 109 Gichannel & Angle For Mounting Ct Pt Combined Units With Nuts And Bolts ( Size 100 X 50 X 5 Mm ) 110 3Ph4 Wire Ht Ct / Pt Operated Fully Static Smart Tri-Vector Energy Meters Dlms Compliant Category C With Rs232 Port . 33Kv / V3 / 110V / V3, Ph-N ( 3P, 4W ) Meters For Measurement Of Different Electrical Parameters Including Active Energy ( Kwh / Mwh ) , Reactive Energy ( Kvarh / Mvarh ) , Apparent Energy ( Kvah / Mvah ) Etc. ( Make L&T, Secure Or Abb ) . 111 Pvc Copper Wire Flexible Multi-Strand Of Required Size For Secondary Connections For Ct Wiring The Minimum Wire Size Shall Be 4 Mm2 ( Ryb ) And For Pt Wiring Minimum Wire Size Shall Be 2.5 Mm2 ( Ryb ) . 112 Copper Lugs Preferably Ring Type Duly Crimped For Termination Of Wires And Tapes 113 Acsr Jumpers With Hardware Fittings Like Acsr To Ct / Pt Unit Bush Clamp, Other Hardwares As Per Site Requirement 114 Earthing 40 Mm Gi Pipe Or 20 Mm Gi Rod, 2.5 Mtr For Ct / Pt Combination Unit. Earthing Of Metering Cubicle Through Two No 25 X 5 Mm Flat Iron. 115 11 Kv Indoor Switchgear 116 11 Kv Vcb Panel Board ( 12 Kv, 1250A, 25 Ka, Outdoor ) With O / C, E / F Relays ( Iec61850 ) , Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows With Annunciation Relays, 3-Phase Tri-Vector Meter -5 Amps, Dlms Compliant With Rs-485 Port ( 1 Incomer & 3 Outgoing ) 117 11 Kv Bus Coupler Along With Adaptor Panel 118 11Kv, Gapless Surge Arrestor, 9 Kv , 10 Ka , La With Polymer Housing, Stn. Type ( 4 / 5 / 6 Sets ) 119 100 Kva, 11 / 0.433Kv, 3-Phase Distribution Transformers With Bimetallic Terminal Connectors Energy Level-2, ( Aluminium Wound ) 120 11 Kv Isolater, Double Break, 3-Pole, 600 Amp, Horizental Mounting Type With Earth Switch 121 11Kv Horn Gap, 3-Phase, 3-Pole, 200 Amp 122 Pvc Armoured Cable ( Lt ) , 120Mm2 ( 3.5 Core ) 123 St Poles ( St-410 ) , Sp-33, 9 Mtrs.Long ( For 4 No. O / G Structures And 2 No. Aux Sub Station ) 124 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5Cum Per Pole 125 Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20Mm 2.5 Mtr Long Through Gi Strip 126 Mccb-200 Amp With Enclosure 127 Galvanisedironoff Sorts 128 Earthing Of 100Kva Substation --Excavation Ofearth Pit Of Dia650 Mm & Depth 3000 Mm, Installation Ofearthing Pipe Of 40 Mm Nominal Bore & 4Mm Wall Thickness & Length 2.5 Mtr Long As Per Is 1239.Gi Strip For Neutral Earthing Of Size 75 Mm X10 Mm& 50 Mm X 6 Mmfor Connection Of Transformer Body, G.O Set & Lightening Arrestor As Per Is 2629 / 85, Gi Nuts & Bolts, Refilled With Earth Enhancement Materials And Earth Chamber Made Of Brick Masonary With Rcc Slab Cover. 129 11 Kv Xple Power Cables 130 11 Kv, 630 Mm² Single Core Xlpe Armoured, Frls. ( With One Spare Length ) 131 11 Kv, 3- Core, Xlpe 185 Mm² Armoured, Frls, 132 11 Kv Indoor Heat Shrinkabler Cable Termination Kits For 630 Mm Sq. Single Core Cable. Id / Od 133 11 Kv Outdoor Heat Shrinkabler Cable Termination Kits For 185 Mm Sq. Three Core Cable. Id / Od
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
36.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
37.
Defence #10372375 Price Bid
Tender For Augmentation Of Electric Supply Under Ge Dehradun; 1 Supply And Laying Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavyduty ) With Aluminium Conductor, 11000 Volts Earthed, Grade Cross Sectional Area 120 Sqmm 3 Core 2 Supply And Laying Xlpe Insulated, Screened, Pvc Bedded, Galvanised Steel Strip Or Wire Armoured, Electric Power Cables ( Heavyduty ) With Aluminium Conductor, 11000 Volts Earthed, Grade Cross Sectional Area 95 Sqmm 3 Core 3 Supply, Jointing And Testing Indoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 50 Sqmm To 95 Sqmm 4 Supply, Jointing And Testing Outdoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 3 Core 50 Sqmm To 95 Sqmm 5 Supply, Jointing And Testing Indoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 3 Core 120 -185 Sqmm 6 Supply, Jointing And Testing Outdoor Type Cable End Termination Joint Heat Shrinkable Suitable For Ht 11 Kv Xlpe Cable 3 Core 120 -185 Sqmm 7 M&L For Underground Pneumatic Horizontal Drilling Of Holes ( Hdd ) Under Road, Pavement, Hard Standing As Required Length At Site By Trenchless Technology Using Ultra Sound Technique With Necessary Horizontal Direction Drilling Machine . The Contractor Shall Be Conduct Under Ground Scanning To Detect Existing Ht / Lt Cable Line , Sewage Line, Ofc Cable Etc To Avoid Damage. The Entry / Exist Hole Must Be Large Enough To Fit The Drilling Tool And The Operator In It So They Can Aim The Tool. The Hole Also Must Be Deep Enough That As The Tool Compacts The Ground And The Surface To Be Remain Undisturbed. The Depth Of The Starting Bore Pit Depends On The Type Of The Soil That Is Being Worked In And How Well It Compacts. The Operator Shall Aim The Tool To The Desire Exit Point And Allow It To Perform It Function Creating A Bore Hole Under The Ground Without Disturbing Surfaces. The Operator Also Should Monitor The Surface To Make Sure That, It Is Undisturbed. As The Tool Near To The Exit Point It Is Slowed Down And The Exit Pit Should Be Dug To Locate Both The Tool And The Bore. As The Tool Enters The Exit Pit The Operator Should Choose Either Dig Up The Tool To Retrieve It Or Reverses The Tool Back Into The First Bore Pit To Retrieve It Including Connected Earth Work, Complete All As Specified And Directed. 8 Supply & Laying Ofhigh Density Polyethylene Pipes ( Hdpe ) Of Pressure Rating Hdpe Pipes Pn 6 Size 110Mm ( 4 ) Laid In Trenches For The Protection Of Ht Ug Cable All As Specified And Directed 9 Excavation In Trenches Soft / Loose Soil Not Exceeding 1.5 Mtr Wide And Not Exceeding 1.5 Mtr In Depth And Getting Out Excavated Soil / Sand / Unsv Lt Cable For Laying Of Cable And Getting Out. 10 Sand Cushioning And Covering Of Ug Cable Using Crushed Metal Sand In Trenches For Cable Protection All As Specified And Directed. 11 Returning Filling In Including Spreading Levelling Watering And Well Ramming In Layers Not Exceeding 25 Cm In Hard / Loose Soil Complete All As Specified And Directed By Engr-In-Charge. 12 Removing Excavated Material Not Exceeding 50 Mtr And Depositing Where Directed At A Level Not Exceeding 1.5 Mtr Above The Starting Point Complete All As Specified. 13 M&L For Laying Reinforced Precast Concrete Cable Cover, Class Hv, Type 1, Flat, Size 300Mmx L80mm X 40Mm To U / G Cable Laid Dry Flat Over The Cable With Width Equal To Length Of The Cable And Abutting Each Other With Gap Between Adjacent Slab Not Exceeding 10Mm Over Under Ground Cable For Cable Protection In Trenches All As Specified And Directed By Engineer-In-Charge. 14 Cutting Existing Road / Hardstand Of Any Type By Using Crow Bar Chisel Uprto Adepthof 30 Cm For Laying Gi Pipe Including Making Good The Surface By Returning Filling Watering Ramming In Layers 150 Mm Thick Pcc 1:2:4 Over 200 Mm Thick Hard Core Of Broken Bricks / Stones Over Returning Filling Watering Ramming In Layers Not Exceeding 25 Cm Thick Complete All As Specified And Directed By Engineer-In-Charge. 15 M&L For Gi Tubing Medium Grade ( Isi Marked ) With All Fitting / Acessories For Protection Of Cable On Pole / Wall And Under Road Crossing Including Clamps, Nut Bolt Etc All As Specified And Directed Ofsize 40Mm Dia 16 Supplying, Installing, Testing And Commissioning Of Indoor Draw-Out With Roll On Floor Type Vacuum Circuit Breaker Panel , Consisting Of 2 Incoming Vcb + 02 Out Going Vcb + 01 Bus Coupler Vcb Rated For 11Kv, 800Amp, Min 25 Ka / 3-Sec, Andbus Pts For Each Bus Section, Confirming To Iec 62271-200, Internal Arc Classified Iac Aflr – Min 25 Ka For 1Sec, Accessibility Class Lsc2b-Pm Class, Comprising Of 800Amp, Continuous Rated Copperbusbars And Droppers, 02 Nos. Rack-In-Rack-Out Handles, Structure Made From Aluzinc / Gi / Crcasheets To Prevent Corrosion And Rusting. The Complete Panel Incl. Ht And Lt Chamber With Frls Wiring Shall Be Manufactured By Approved Oem At Its Own Facility, And Same Will Be Verified Via Stage / Final Inspection.The Switchgear Panel Offered Shall Be An Active Lifecycle Product Of The Oem . Make Of Vacuum Interrupter, Numerical Relay, Cb & Panel Shall Be Same. ( Make: Abb ( Zn1 ) / Siemens Nx- ( Rof ) Air / Schneider ( Pix Rof / L&T ) ) .The Board Shall Consist Of Following Panels:- 17 ( I ) 11Kv, 800Amp, Min 25 Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100 With Roll On Floor Type Vacuum Circuit Breaker Having 03 Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push- Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 24Vdc ) . 18 ( Ii ) Current Transformers 11Kv, 150 / 1 / 1A, Core1: Class 5P10, 5Va, Core2: Class 0.5, 5Va, 3 Nos: 19 ( Iii ) Potential Transformers, Draw-Out Type For Easy Maintenance, 11Kv / Rt3:110V / Rt3, 50Va, Cl.0.5 Withassociated Gun-Type Hrc Fuses And Mcbs For Ht / Lt Isolation - Set Of 03 Nos. The Line Pts In The Incomer Panels Shall Be Floor Mounted Or Roll On Floor Type, It Should Not Be Placed On Top Of The Panel. 20 ( Iv ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Ct Inputs Withmicroprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) 3 Over-Current And 1 - Earth-Fault ( B ) Circuit-Breaker-Failure Alarm, ( C ) Scada Competable Communication On Rs 485 Withmodbus Protocol ( D ) Ct Secondary - 1 A / 5 Amp ( E ) Fault Rocord Min 10 Nos ( F ) Aux Voltage - 24 - 240V Ac / Dc ( G ) Output Contact - Min 4 Nos 21 ( V ) Metering Equipment Including:- ( A ) 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shallbe Communicable On Modbus Via Rs485 Port. 22 ( Vi ) Led Indications :- ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) R-Y-B, ( C ) Dc Available Led With Push-Button ( D ) Ac Supply Fail ( E ) Trip Circuit Healthy 23 ( Vii ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, ( E ) Pt Fuse Failurethe Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 24 ( Viii ) Control Equipment Incl. :- ( A ) 01 X Tnc Switch, ( B ) 01 X Local / Remote Switch, ( C ) 01 X Emergency Trip Push Button, ( D ) Mcbs For Ac ( E ) Mcbs For Dc ( F ) Heater Switch With Thermostat - 01No. ( G ) 3-Pin Socket With On / Off Switch - 01No. ( H ) Cfl Lamp With On / Off Switch - 01No. 25 ( Ix ) Flush Mounted Auxillary Protection Relays Incl:- ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, ( C ) Pt Fuse Failure Relay. ( D ) Dc Supervision Scheme 26 ( B ) 02 X Outgoing Panel, Each Comprising Of :- ( I ) 11Kv, 800Amp, Min 25 Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100. Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 24Vdc ) . 27 ( Ii ) Current Transformers 11Kv, 150 / 1 / 1A, Core1: Class 5P10, 5Va, Core2: Class 0.5, 5Va - Set Of 03Nos. 28 ( Iv ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Ct Inputs With Microprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) 3 Over-Current & 1 - Earth-Fault ( B ) Ccircuit-Breaker-Failure Alarm, ( C ) Scada Competable Communication On Rs 485 With Modbus Protocol ( D ) Ct Secondary - 1 A / 5 Amp ( E ) Fault Rocord Min 10 Nos ( F ) Aux Voltage - 24 - 240V Ac / Dc ( G ) Output Contact - Min 4 No 29 ( V ) Metering Equipment Including:- ( A ) 01 Nos. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Be Communicable On Modbus Via Rs485 Port. 30 ( Vi ) Led Indications - ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) Trip Circuit Healthy 31 ( Vii ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, The Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 32 ( Vii ) Control Equipment Incl. ( A ) 01 X Tnc Switch, ( B ) 01 X Emergency Trip Push Button, ( C ) 01 X Local / Remote Switch, ( D ) Mcbs For Ac / Dc Isolation ( E ) Heater Switch With Thermostat - 01No. ( F ) 3-Pin Socket With On / Off Switch - 01No. ( G ) Cfl Lamp With On / Off Switch - 01No. 33 ( Viii ) Flush Mounted Auxillary Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, 34 ( C ) 11Kv Bus-Coupler Vcb Panel 35 Same Description As Incomer Panel Except Meters, Current Transformer, Potential Transformer And Protection & Auxiliary Relays : 36 ( D ) The Panel Shall Be Complete With All Allied Items And Accessories, Including:- ( I ) Cost Of Construction Of Foundation As Per Manufacturer Design, Including Foundation Frame ( Supplied By Oem ) , Channels Etc. For Ht Panel As Required At Site Are Deemed To Be Included In The Quoted Rate. ( Ii ) Each Vcb Panel Being Floor-Mounted, Air-Insulated, Fully-Compartmentalizeds The Oem Shall Supervise And Certify The Commissioning / Charging Of Equipment. ( Iii ) Complete Panel Will Shall Be Suitable For Future Intigration Withwith Scada ( Iv ) Foundation Frames Shall Be Inclusive In The Scope Of Supply Of Oem. ( V ) Make Of Vacuum Interrupter, Numerical Relay, Cb & Panel Shall Be Same. 37 Supplying, Installing, Testing And Commissioning Of Indoor Draw-Out With Roll On Floor Type Vacuum Circuit Breaker Panel , Consisting Of 2 Nos Vcboutgoing + 01 Nos Bus Raiserrated For 11Kv, 800Amp, Min 25 Ka / 3-Sec, Andbus Pts For Each Bus Section, Confirming To Iec 62271-200, Internal Arc Classified Iac Aflr – Min 25 Ka For 1Sec, Accessibility Class Lsc2b-Pm Class, Comprising Of 800Amp, Continuous Rated Copperbusbars And Droppers, 02 Nos. Rack-In-Rack-Out Handles, Structure Made From Aluzinc / Gi / Crcasheets To Prevent Corrosion And Rusting. The Complete Panel Incl. Ht And Lt Chamber With Frls Wiring Shall Be Manufactured By Approved Oem At Its Own Facility, And Same Will Be Verified Via Stage / Final Inspection.The Switchgear Panel Offered Shall Be An Active Lifecycle Product Of The Oem ..The Board Shall Consist Of Following Panels:- 38 ( A ) 02 X Outgoing Panel, Each Comprising Of :- ( I ) 11Kv, 800Amp, Min 25 Ka / 3-Sec, Draw-Out Vacuum Circuit Breaker As Per Iec-62271-100. Vacuum Circuit Breaker Having 03Nos. Vacuum Bottles Of Same Make As Of Circuit Breaker, Motorized Spring Charging Mechanism ( 230Vac ) With Integral Spring Charging Handle For Manual Charging, Associated Push-Buttons, Anti-Pumping Feature, And Associated Shunt Trip / Close Coils ( 24Vdc ) . 39 ( Ii ) Current Transformers 11Kv, 150 / 1 / 1A, Core1: Class 5P10, 5Va, Core2: Class 0.5, 5Va - Set Of 03Nos. 40 ( Iii ) Main Protection Relay Shall Be Numerical Ied Relay Confirming To Iec60255, Having 04Ct Inputs With Microprocessor Based Protection Scheme For Tripping The Breaker On Various Faults Like ( A ) 3 Over-Current & 1 - Earth-Fault ( B ) Ccircuit-Breaker-Failure Alarm, ( C ) Scada Competable Communication On Rs 485 With Modbus Protocol ( D ) Ct Secondary - 1 A / 5 Amp ( E ) Fault Rocord Min 10 Nos ( F ) Aux Voltage - 24 - 240V Ac / Dc ( G ) Output Contact - Min 4 No 41 ( Iv ) Metering Equipment Including:- ( A ) 01No. Multi-Function-Meter ( Acc.Cl.0.5 ) Shall Be Provided With Lcd Display For Measuring Current, Voltage, Power, Power-Factor And Energy-Parameters, Total Harmonic Distortion And Max. Demand Indication, Same Shall Becommunicable On Modbus Via Rs485 Port. 42 ( V ) Led Indications - ( A ) Breaker On / Off / Trip / Spring-Charged, ( B ) Trip Circuit Healthy 43 ( Vi ) 08-Window Annunciator With Hooter To Indicate Following Alarms :- ( A ) Oc Trip, ( B ) Ef Trip ( C ) Trip Circuit Failure, ( D ) Inter-Tripping Fault, The Annunciator Will Be Complete With Required Acknowledge / Test Buttons As Required 44 ( Vii ) Control Equipment Incl. ( A ) 01 X Tnc Switch, ( B ) 01 X Emergency Trip Push Button, ( C ) 01 X Local / Remote Switch, ( D ) Mcbs For Ac / Dc Isolation ( E ) Heater Switch With Thermostat - 01No. ( F ) 3-Pin Socket With On / Off Switch - 01No. ( G ) Cfl Lamp With On / Off Switch - 01No. 45 ( Viii ) Flush Mounted Auxillary Protection Relays Incl. ( A ) Trip Circuit Supervision Relay, ( B ) Master Trip Relay, 46 ( B ) 11Kv Bus-Raiser 47 With Potential Transformers, Drawnout Type For Easy Maintenance, 11Kv / Rt3:110V / Rt3, 50 Va, Cl0.5 With Associated Gun Type Hrc Fuses And Mcbs For Ht / Lt Isolation - Set 3 Nos 48 ( C ) The Panel Shall Be Complete With All Allied Items And Accessories, Including:- ( I ) Cost Of Construction Of Foundation As Per Manufacturer Design, Including Foundation Frame ( Supplied By Oem ) , Channels Etc. For Ht Panel As Required At Site Are Deemed To Be Included In The Quoted Rate. ( Ii ) Each Vcb Panel Being Floor-Mounted, Air-Insulated, Fully-Compartmentalizeds The Oem Shall Supervise And Certify The Commissioning / Charging Of Equipment. ( Iii ) Complete Panel Will Shall Be Suitable For Future Intigration Withwith Scada ( Iv ) Foundation Frames Shall Be Inclusive In The Scope Of Supply Of Oem. ( V ) Make Of Vacuum Interrupter, Numerical Relay, Cb & Panel Shall Be Same. 49 Note:- ( I ) License Parter, System Integrator, Panel Builder, Half-Panel Is Not Allowed For 11Kvvcb. All Works Shall Be Done At Own Works. ( Ii ) All Items Will Be Transported In Wooden Packaging To Avoid Any Damage. Acceptance Of Material Will Be Discretion Of Ge. Contractor Has To Remove The Material In Case Of Rejection Of Material At No Extra Cost. ( Iii ) Factory Acceptance Test Shall Be Carried Out For11 Kv Ht Vcb. ( Iv ) Fabrication Of Adaptor Panel Incl Alteration / Couple And Matching Bus Bar Required At Site With Existing Panel Is Deemed To Be Included In Quoted Rate.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 6
Uttarakhand View Result →
38.
Public Administrative Department #10304588 Price Bid
Work Of Replacement Of Existing Hydraulic System With Energy Efficient Hydro-Pneumatic System At The Main Pump Room In Kem Hospital.- 1 Removing Of Existing 50 Hp Pumps, Including Removing Cable Termination, Cables, Lugs, Fittings, Pipe Connections, Fittings, Nuts Bolts, Washer, Stand, Pads Etc Complete In All Respect And Keeping The Same In The Department Store Area As Directed By Site In Charge 2 Breaking Of Existing Rcc Padestal Of Pumps And Disposal Of The Same For 50-100 Hp Pumps 3 Constructing Rcc Pedestal For Pumps Are Per Drawings, Details And Specifications Etc Complete ( For 3 + 1 Pump Set ) For 25 Hp & 30 Hp Pumps 4 Providing And Fixing In Position G.I. Heavy Grade C Class Pipe Of 200Mm Dia. 5 Supplying & Laying C Class G.I. Pipe ( I.S.I Mark ) For Suction / Delivery Line Etc.: 100 Mm Dia 6 Providing And Fixing In Position G.I. Heavy Grade C Class Pipes 80 Mm 7 Providing And Fixing In Position G.I. Heavy Grade C Class Pipes 50 Mm 8 Providing And Fixing In Position G.I. Heavy Grade C Class Pipes 25 Mm 9 Ci Body Butterfly Valve 200 Dia 10 Ci Body Butterfly Valve 100 Dia 11 Ci Body Butterfly Valve80 Dia 12 Ci Body Butterfly Valve 50 Dia 13 Ci Body Butterfly Valve 40 Dia 14 Ci Body Non Return Valve 200 Dia 15 Ci Body Non Return Valve 80 Dia 16 Ci Foot Valve100 Dia 17 Providing And Fixing Calibrated Pressure Gauge 100Mm Dia With U Tube Syphon And Isolation Cock Including Fixing With Jointing Material Etc Complete. 18 Providing And Fixing In Position Ms Fabricated Brackets / Supports For Fixing The Ci / Pvc Pipes Including Fixing Of Brackets On Wall / Slab / Ceiling As Required With U-Bolts, Nuts And Bolts Etc Complete. 19 Supplying, Installing, Testing And Commissioning Of Priming System ( 3 Hp Submersible Pumpset-2 Nos ) For Priming Of Hydraulic System Pumpset With Electrical Cables, Lugs , Gland, Includingnrv, Gate Valves, Necessary Plumbing , Starter Panels, Pressure Switch Control Wiring Sensorsfor Low / High Water Level, Dry Run Protection, Cable Tray Wihting The Manifold For Power Supply To Pumps From Control Panel For Operation. 20 Supplying, Installing, Testing And Commissioning Of Hydropneumatic System Pumps ( 3 Working + 1 Standby ) Of 30 Hp Capacity Including Its Baseplate, Vibration Isolation Pads, Lifting Hooks, Anchor Fasteners, Etc Complete In All Respect. 21 Providing And Fiing In Position 200Mm Ss 316 Grade Manifold For Suction And Delivery Header With Blank Off Ss 316 Flanges On Both Sides Of The Header Including Ss Nut Bolts, Washers And Rubber Gasket. 22 Supplying, Installing, Testing And Commissioning Of Pre-Charged Diaphragm Pressure Vessel With Interchangeable Membrane, Charging Connection, Connected To Outlet Header With Necessary Flanges, Gaskets, Isolating Valves, Nuts / Bolts Etc. Complete ( Size Of Pressure Vessel Shall Be 500 Liters ( Approx. ) Or As Per Manufacturer Recommendation ) Tank 10 Bar Etc Complete. 23 Supplying, Installing, Testing And Commissioning Of Vfd Operated Electrical Control Panel With Forapprox.25Hp-30Hp Pump With Plc Based System And Works On The Pressure Sensing With Pressure Switch And Water Level Control In Ug And Overhead Tanks, Control Panel For All Vfd Operated Pumps Including Type Ii Coordination For Bypass Arrangement Incase Of Failure Of All Vfds, Electrical Cables, Lugs, Glands And Its Terminations, Feather Touched Led / Lcd Screen Panel For Operation Control Panel Should Have Over Current, Over Voltage, Surge, Earth Leakage And Phase Protection, Bms Compatible For Programming, Plc Based Vfd For The Frequency Control As Per The Demand Flow, Pump Running And Fault And Capable To Communicate With Other Controllers Following Modbus-Rtu Or Bacnet Class-2 Protocol Through Rs485 Port. System Should Be Capable To Compensate For Frictional Losses At Lower Flows. All Alarms Should Be Displayed In The Controller. System Should Be Equipped With Dry Running Protection Etc Complete In All Respect. 24 Supplying, Installing, Testing And Commissioning Of Float Sensors In Ug Tank For Non Operation Of Pumps During Low Water Level 25 Providing And Fixing In Position Gun Metal Heavy Duty Air Relies Valve Hawa Make Conforming To Is 778 With Screwed Female Endincluding Testing And Commissioning. Etc Complete. 26 1St Category Cu Armoured Cables Frlsz Outer Sheathed- 3.5C X50 Sq.Mm 27 Cable End Termination For Copper Cables – 3.5C X 50 Sq.Mm 28 Earthing Continuity Conductors -Bare G.I. Conductor Size 10 Swg 29 G.I. Trunking / Duct / Raceway & All Other Accessories – 300 X 40Mm ( W X H ) - ( 14 Swg – 2Mm ) With Cover Without Partition 30 Supply, Installation, Testing & Commissioning Of Pressure Switch To Actuate ( `Cut-Off And / Or `Make Contact As Required ) At Pre-Set Pressures With All Necessary Fitting, Adapters And Teflon Tape Fixing Etc Complete. 31 Supply, Installation, Testing & Commissioning Of 50Mm Dia Imported Float Valve To Operate At A Pressure Of 2.5Kg / Cm2 To Be Fixed In Each Overhead Tank Outlet To Function Closing When The Tank Reaches The Maximum Water Level With Inlet And Outlet Connections Etc Complete. 32 Sitc Of Ss Single Flanged Flexible Rubber Connector Of200 Dia 33 Sitc Of Ss Single Flanged Flexible Rubber Connector Of100 Dia 34 1St Category Cu Armoured Cables Frlsz Outer Sheathed- 3C X2.5 Sq.Mm 35 Supply And Fixing Of Tinned Plated Copper Lugs For 3Core 2.5 Sq. Mm. Copper Cable 36 1St Category Cu Armoured Cables Frls Outer Sheathed- 4C X 1.5Sq.Mm 37 Earthing Station With 600 Mm X 600 Mm X 6 Mm Galvanised Iron Plate & 50 Mm Dia. G.I. Pipe, 3000Mm Long Gi Pipe ( Class B Or Better ) Earth Pit As Per Is 3043. The Earth Pit Shall Be Provided With Watering Pipe ( Class B ) With Wire Messed Funnel, 25X3 Gi Strip / / 2X8swg G.I. Wire Up To Chamber ( Wire Or Strip Size As Per Fault Level ) , Disconnecting Links With 600 X 600 Mm ( Clear ) Rcc Chamber & Heavy Duty 3Mm Thick Ci Chequered Plate Cover With Hinge & Stainless Steel Bolts. Bentonite / Charcol & Salt Shall Be Provided For Earth Pits. Excavation, Back Filling, Removal Of Excess Soil Is Included In The Scope 38 Earthing Continuity Conductors -25 X 3Mm Gi 39 2Nd Year Csmc Cost ( After 1 Year Dlp ) 40 3Rd Year Csmc Cost 41 4Th Year Csmc Cost 42 5Th Year Csmc Cost
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
39.
Defence #10295943 Price Bid
Tender For Special Repair And Replacement Of Old Unserviceable Ocb To Vcb And Connected Items At Ima Dehradun.; 1 Dismantling HT 11 Mtr SP 55 steel tubular four pole structure ,disconnecting the HT cables, earthing leads/strips incoming and outgoing HT cable of existing size, disconneting/ dismantling the complete GOD system of existing size and taking out the complete structure from the site of any type, lifting transporting the same to storeyard to keep four pole structure in safe custody complete all as specified and directed. 2 Dismantling HT 11 Mtr SP 55 steel tubular two pole structure ,disconnecting the HT cables, earthing leads/strips incoming and outgoing HT cable of existing size, disconneting/ dismantling the complete GOD system of existing size and taking out the complete structure from the site of any type, lifting transporting the same to storeyard to keep four pole structure in safe custody complete all as specified and directed. 3 Supply, installation, testing & commissioning of 11 KV of rating 630 Amps RMU unit outdoor type IP-54 protection duly painted (Paint shade in painted Alu Zn/RAL 7032 on sheet steel for door and covers), SF-6 gas insulated RMU (Ring Main Unit) four way comprising of two (02 Nos) numbers manually operated load break switch for incoming,Two (02 Nos)number Vacuum Circuit Breaker as outgoing, inside SF6 gas filled stainless steel (nonferrous and nonmagnetic grade) tank having minimum thickness 2.5 mm +/- 0.5 mm having IP-67 degree of protection internal are classified 21 KA/ 03 Sec for cable box and tank bothwith painting as per manufacturer specification & leak rate of SF-6 gas less than 0.1%, RMU should be provided with Copper Bus bar, one number fault passage indicator with each incoming and outgoing, mechanism for interlocking arrangements for powered relay complete with all accessories as under :-(a)RMU type installation Outdoor Extensible type, arc proof as per IEC:62271-200 for design, manufacturing and testing. The RMU must have the following features/specifications:- (i)Rated voltage upto - 12 KV. (ii) Rated power frequency withstand voltage - 28 KV. (iii) Rated lightning impulse with stand voltage - should be minimum75 KVP.(iv) Rated current for ring mainfeeder - 630 A. (v)Rated current for VCB feeder - 630 A. (vi)Rated short-time current - 21KA/3 Sec.(vii)Rated short making current - 52.5kA(viii)Ambient temperature - (-1 degree Celsius to +45 degree Celsius). 4 (ix) Degree of protection against accidental contact and ingress of foreign objects must be assured as under:-(a) SF 6 tank : IP-67. (ab) Out door enclosure IP 54.(x)Each load break Switches includes :-(aa) SF6 three position switches with position ON-OFF-EARTH, (ab)Manual operated spring mechanism ON-OFF-EARTH, (ac) Mechanical indicators for position ON-OFF-EARTH, (ad) Mimic diagram at the front facia of RMU, (ae)Capacitive Voltage indicator, (af)Padlocking facility, (ag)Fault passage indicator for Earth Fault.(xi) Each vacuum circuit Breacker includes :-(aa)Manual VCB with position ON-OFF manual spring charging mechnism with in built spiring charging handle, mechanically latched ON/OFF push buttons. (ab)Manual line disconnector with three posotion switches ON-OFF-EARTH, (ac)Numerical relay for Overcurrent and earth fault protection, (ae)Three phase definite time over current and short-circuit protection with variable tripping times (ANSI 50/51), 3 Phase over current protection with selectable inverse time characteristics and definite time short-circuit current) (ANSI 2021), definite, (af)Capacitive Voltage indicator, (ag) Padlocking facility, (ah)Dedicated CTs for protection.(xii)Operating handle - 1 number, (xii) Right angled Cable boots - 3x sets, (xiv)Capacitor(xv) Any Other standard accessories required for efficient operation and PCC foundation of RMU as per OEM recommendations. 5 Disconnecting the HT cables, earthing leads/strips of 11 KV OCBs and taking out the complete OCBs from the site of any type and capacity, lifting transporting the same to storeyard to keep OCBs in safe custody complete all as specified and directed. 6 Supply, installation, testing and commissioning of 11 KV, 630 Amps, 26.3 KA for 3 sec HT vacuum circuit breaker panel for incomer confirming to the IS 13118/1991, IEC 62271-100/200, IAC-AFLR- 25 KA for 1 sec, PM LSC-2B, front accessed comprising of the following equipments :- 7 (a) Min 630 Amps continuous rating copper bus bar droppers and bus bars with heat shrinkable PVC Sleeves. 8 (b) Truck mounted Floor rolling vacuum circuit breaker LK (L&T) equivalent in Siemens/Schneider withend sheet, castle lock and rear extension 9 (c) Motorised spring charging mechanism. 10 (d) Interpanel barrier to prevent arc propagation from one panel/compartment to other. 11 (e) Earthing truck rated for full making capacity with provision for safe and reliable position indicator. 12 (f) Cast resin current transformer, 11 KV, 100/50/5 ± 5 Amps having protection core class IP10, burden of 15 VA and breaking cap of 26.3 KA for 3.0 second - 03 Nos. 13 (g) Cast resin potential transformer, 11 KV/√3/110V/√3, 100 VA/CL 1.0 - 03 Nos with desired capacity PT fuses. 14 (h) Accessories like local remote selector switch, Breaker control switch (T-N-C) space heater with Thermostate DC and AC control Ckt protection through MCB, indicating LED lamps for RYB phases spring charged, DC supply healthy breaker ON/OFF, Breaker in service, Test, Disconnected Position, Annunciator window and hooter. 15 (j) Multifunction meter with RS 485 port. 16 (k) SCADA compatible numerical O/C & Earth fault relay type modbus RTU. 17 (l) Trip ckt supervision (ii) Master trip (ii) Auxiliary relay (iii) Arc flash supervision of circuit breaker (iv) cable and bus bar compartment. 18 (m) Anti pumping relay panel shall have following additional features:- 19 (n) Continuous rated closing/tripping coils. (ii) Integral spring charging handle. (iii) Fully internal arc tested (25 kA for 1 sec) as per latest IEC 62271-200 Norms. 20 (o) In built power pack 24 volt DC as required for protection relays and other equipments/systemr. 21 (p) Breaker shall be provided with following features:- 22 (i) Auxiliary switch with 6 NO + 6NC contacts mounted on the draw out portion of the switchgear. (ii) Position/ cell switch with 3 NO + 3 NC contacts one eact for TEST and SERVICE position. (iii) Auxiliary switch with 4 NO + 4 NC contacts mounted on the stationary portion of the operated mechanically by a sliding lever from the breaker in service position. 23 Supply, installation, testing and commissioning of 11 KV, 800 Amps, 26.3 KA for 3 sec HT vacuum circuit breaker panel for Bus coupler confirming to the IEC 62271-200, IAC-AFLR-25 KA for 1 sec, PM LSC-2B, front accessed comprising of the following equipments :- 24 (a) 800 Amps continuous rating copper bus bar. Droopers and busbars shall be Raychem insulated. 25 (b) Truck mounted Floor rolling vacuum circuit breaker LK (L&T) equivalent in Siemens/Schneider withend sheet, castle lock and rear extension 26 (c) Motorised spring charging mechanism. 27 (d) Interpanel barrier to prevent arc propagation from one panel/compartment to other. 28 (e) Earthing truck rated for full making capacity with provision for safe and reliable position indicator. 29 (f) Accessories like local remote selector switch, Breaker control switch (T-N-C) space heater with Thermostate DC and AC control Ckt protection through MCB, indicating LED lamps for RYB phases spring charged, DC supply healthy breaker ON/OFF, Breaker in service, Test, Disconnected Position. 30 (g) Antipumping relay panel shall have following additional features:- 31 (h) Continuous rated closing/tripping coils. (ii) Integral spring charging handle. (iii) Fully internal arc tested (25 kA for 1 sec) as per latest IEC 62271-200 Norms. (iv) Racking in/out, Manual closing/tripping of the CB with compartment door closed. 32 (j) Breaker shall be provided with following features:- 33 (i) Auxiliary switch with 6 NO + 6NC contacts mounted on the draw out porition of the switchgear. (ii) Position/ cell switch with 3 NO + 3 NC contacts one each for TEST and SERVICE position. (iii) Auxiliary switch with 4 NO + 4 NC contacts mounted on the stationary portion of the operated mechanically by a sliding lever from the breaker in service position. 34 Note for item No. 5 and 6:-(a) Electrical and mechanical interlocking between all incoming breaker and bus coupler to avoid double supply in outgoing breakers.(b) The VCB should be matched with existing VCB/OCBs including Adopter panel required for connection with existing panel, extension of bus bar and weather proof bus duct, nuts bolts and painting with colour etc as required at site complete all as specified and directed.(c) Contractor shall submit the drawing as per CA specification to Garrision Engineer before placing orders to original manufacturers of panels.(d) Minor items/parts required for making connections in respect of incoming outgoing and earthing etc are deemed to be included in the quoted rates by the contractor.(e) The VCB should be tested at site after insatallation with primary injection system according to the load of feeders and submit the test report of all VCB before pre commissioning in booklet form, cost of the same included in the quoted rate. 35 Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded galvanizedsteel strip or wire armored, electric power cables (Heavy duty) 11000 volts grade with stranded aluminum conductor of cross sectional area 3 core 120 sq mm complete all as specified and directed. 36 Material and labour for cable jointing kit for 11 KV (Earthed) grade cable for indoor/outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm complete all as specified and directed. 37 Material and labour for PCC 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in VCB fondation complete all as specified and directed. 38 Material & labour GI tube light grade 100 mm for protection ofUG cable including dismantling complete all as specified and directed. 39 Supply and fixing HT cable root indicator of cast iron embedded in PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate) of size 100x100x200 mm foundation upto ground level including necessary earth work in any type of soil complete all as specified and directed. 40 Material and labour for earthing with steelearth plate electrode ofsize 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32 X 6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate,removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed. 41 Excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth in soft/lose soil for laying cable/taking out under ground cable, GI pipes and bricks laid under cable and getting out in soft/loose soil complete all as directed. 42 Returning, filling in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick in soft/lose soil after cable/pipes are laid and tested complete all as directed. 43 Removing the excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as directed. 44 Material and labour for sand cushioning to under ground cables 8 cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as directed. Note:- sand will be measured after punning 8 cm. 45 Material and labour for un-reinforced precast concrete cable cover HV type I, flat size 300 mm X 180 mm X 40 mm as protection to underground cable laid dry and flat adjoining each other complete all as directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 8
Uttarakhand View Result →
40.
Housing Urban and Rular Development #10282106 Price Bid
Tender For Rmo Electrical And Mechanical Services At Delhi Vidhan Sabha, Old Sectt., Delhi. (Sh - Renovation Of The Minister Office And Other Misc. Works). - 1 Sub Head - I (EI Works) 2 S/I/T/C of Magnetic track linear spotlight for Rue Slim with LED (Light Emitting Diode) system power: 12W, luminous flux of luminaire 960lm, colour temperature of 4000K, Neutral white, CRI>80,24V DC,direct light emission, beam angle of 36deg aluminium housing polyester Black powder coat applied over a 5- stage pretreatment, Dali Control Gear Protection class II, IP20 L = 327 mm, B= 22 mm, H = 44 mm. etc. complete as reqd. 3 S/I/T/C of Non LED Rescessed Rue - Track (With Trim) Without Luminary Element Aluminium Optics: Without Diffuser Finish: Black Control Gear: Electronic Control Protection Class: II IP 20 L:1000mm, B:26.2 mm, H: 52 mm etc. complete as reqd. 4 S/I/T/C ofCOB based recessed downlight luminaire Amber, System power:12W, Luminous flux of luminaire 1200lm, Colour temperature of 4000K, Neutral white, CRI>80, 230 V constant current driver, 70% of luminous flux after 50,000 operating hours; Energy-efficient COB, Direct light emission, Luminaire housing in aluminium, Polyester powder Black coloured coat applied over a 5-stage pre-treatment ceiling trim, Lens with anti glare reflector UGR <16 and a beam angle of 38°, ZHLS (ZERO HALOGEN LOW SMOKE) wiring, Electronic control gear Protection class II, IP 20 Ø = 85 mm, H =100 mm etc. complete as reqd. 5 S/I/T/C of Surface mounted LED strip (flexible) , 2835 SMD package with a thermal tape with high thermal conductivity, system power: 15 W/metre, luminous flux 1200lm, colour temperature of 4000K, CRI>80, Anodized aluminium extrusion, Opal diffuser, 12V DC, constant voltage driving circuit,electronic control gear. IP20 L-1000m etc. complete as reqd. 6 S/I/T/C of Recessed wall washer Link W with LED(Light Emitting Diode) system power: 20W, luminous flux of luminaire 1300 lm, colour temperature of 4000K, neutral white, CRI>80, 230V constant current driver, 70% of luminous flux after 50,000 operating hours, energy efficient LEDs, direct light emission, support profile in aluminium powder coated white, reflector for asymmetric light throw with linear prismatic diffuser, electronic control gear, Protection class II, IP20, L=280mm, B = 45mm,H = 50mm, cutout = 275 mm x 40 mmetc. complete as reqd. 7 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. 8 Group C 9 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 10 Group C 11 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 12 3 x 1.5 sq. mm 13 3 x 4 sq. mm 14 3 x 6 sq. mm 15 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 16 5/6 amps switch 17 15/16 A switch 18 3 pin 5/6 A socket outlet 19 6 pin 15/16 A socket outlet 20 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. 21 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 22 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 23 3 Module (100 mmX75 mm) 24 6 Module (200 mmX75 mm) 25 8 Module (125 mmX125 mm) 26 12 Module (200 mmX150 mm) 27 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 28 20 mm 29 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 30 20 mm 31 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 32 4 way (4 + 12), Double door 33 8 way (4 + 24), Double door 34 12 way (4 + 36), Double door 35 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator). i) 2 + 4 way/ 6 way, Double door 36 Supplying and fixing Cable End Box (Loose wire box)(IP 43) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with testing and commissioning etc. as required. 37 For 8 way, Double door SPN MCBDB 38 Supplying and fixing 5 amps to 32 amps rating 240 volts C curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. 39 Single pole 40 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 41 Supply, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R- 407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 Degree Celsius. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electro technical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only 42 1.5 TR with 5 Star BEE Rating 43 2.0 TR with 5 Star BEE Rating 44 Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector. 45 12 -15 watt 46 Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round /square/Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS: 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltag AC 140-270 Volt, freq 50/60 hz, Operating temp range - 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K / 6000°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminum Body including trim. 47 12 -15 watt 48 Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., offollowing body material and construction as per IS : 10322 with driver as perthe requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuitprotection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified GlareRating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade markcertificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumenefficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL labfor all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) 49 36 watt 50 SH:- II (Water level Controller System) 51 Supply, installation, testing, and commissioning of a microcontroller based wireless controller system designed for managing water levels and pressure across multiple remotely situated tanks. The wireless controller communicates on 865~868Mhz band for long range communication. This control system integrates microcontroller technology with wireless data reception capabilities to receive various sensor data wirelessly to indicate & control water automation system. It will indicate water level in Percentage with One percent resolution alongwith tank ID through 4-digit LED/LCD display (minimum 56mm height) for real-time visualization of water levels and sensor data, alongside four potential-free relays that enable the system to operate single or dual motors (three-phase) based on specific conditions. The controller starts the motors when water levels in any linked tank drop below predetermined thresholds and stopping them when all tanks reach capacity. It also responds to data from pressure transmitters, ensuring motors operate within defined pressure ranges in pipeline. It must have a built-in RTC with timer functions, enabling automated motor control based on configurable schedules, while providing comprehensive runtime statistics for monitoring purposes. There should be an audio & visual alarm, if water level in any tank cross threshold limit for overflow level. It should also give visual indication for various fault conditions. Operating voltage single phase 180~260Vac. It can also indicate status of motorized valve and minimum number of opened valves can be set beyond which it will stop the motor to avoid excessive pressure in pipeline. It will also indicate rising/ falling trend of water level in overhead/ underground tank. 52 It should have RS 485/Modbus output to interface with Variable Frequency Drives (VFDs), Building Management Systems (BMS), and Remote Terminal Units (RTUs) to ensure seamless integration within larger infrastructure frameworks and facilitates data exchange on water levels, motor statuses, sensor configurations, and operational commands. It should be capable to change internal setting through modbus from RTU/ BMS system. The controllers enclosure should be made from minimum 0.80mm thick MS sheet with a powder-coated finish and a 3mm thick polycarbonate sheet protecting the display area. It must confirming to standards for fire hazard (IEC 60695- 2-10:2021) and ingress protection (IP65 per IS/IEC 60529:2001), ensuring reliability in various environmental conditions. It should have suitable fixing/ mounting arrangement. 53 Supply, Installation, Testing & Commissioning of Battery operated (to power minimum 8Year) RF based ultra low powered wireless water level data sump transmitter (minimum 15dBm power) operating in frequency band 865~868mHZ, confirming to EN 300 220 and ingress protection IP68, with scale and corrossion free capcitance based level sensor to measure water level percentage from 0% to 100% (± 5% with 1% resolution for tanks upto 10mtr depth with auto calibration sensor. It should also calculate trend & rate of rise/ fall of water level and transmit the data alongwith water level data. It will have input for detection of conductivity based flow in pipeline and on/off status of motorized valve and send the data wirelessly. It should have a technique to avoid collision of RF signal and minimise corruption of data. It should have CRC check in transmitted data to detect error in block of data. 54 Supply, Installation, Testing & Commissioning of Battery operated (to power minimum 8Year) RF based ultra low powered wireless water level data top transmitter (minimum 15dBm power) operating in frequency band 865~868mHZ, confirming to EN 300 220 and ingress protection IP68, with scale and corrossion free capcitance based level sensor to measure water level percentage from 0% to 100% (± 5% with 1% resolution for tanks upto 10mtr depth with auto calibration sensor. It should also calculate trend & rate of rise/ fall of water level and transmit the data alongwith water level data. It will have input for detection of conductivity based flow in pipeline and on/off status of motorized valve and send the data wirelessly. It should have a technique to avoid collision of RF signal and minimise corruption of data. It should have CRC check in transmitted data to detect error in block of data. 55 Supply, Installation, Testing & Commissioning of 230Vac/ 5V DC operated RF signal booster operating in Frequency band 865~868mHZ confirming to EN.300.220 to relay/ transmit the RF signal received from multiple transmitters to further distance with LED based instant indicator. It should have a technique to avoid collision of RF signal and minimise corruption of data. A mechanism should be there to avoid circular transmission of data between repeaters. LED based visual indication should be there to indicate signal strength of received wireless data. It should have RF receiving sensitivity of minimum -125dBm and transmission power of minimum 15dBm. It should be configurable to filter out RF signal of particular transmitters to reduce the transmission signals in Air. It should have shock proof ABS body with IP65 rating and must have suitable mounting arrangements on wall or stand. 56 Supply, Installation, Testing & Commissioning of 12V DC operated wireless RTU to receive data wirelessly from remote sensor data tansmitters/ RF boosters and push the data to BMS/ controller unit through UART and to the server through 4G/ 5G GSM network. This device will be equipped IOT sim of cellular network service providers. It should have LCD/ OLED screen to display various parameters and status of network/ connectivity. The enclosure should be IP65 rating with suitable mounting arrangements. Various settings should be configurable through common web browser using wifi feature. 57 Supply, Installation, Testing & Commissioning of Web based remote monitoring/ control system: Providing web based remote Water level monitoring/ control system by providing access to controller/ information panel at Central server of minimum Tire-III level data centre in India. It will indicate various data/ parameters in user friendly manners. It will also show data in graphical/ CSV format which can be downloaded. Various parameters full, low and overflow limits of individual tanks can be configured through this web interface. Other parameters related to operation of motor can also be configured remotely. It can be access through any web browser with multi-level user authentication. It will trigger SMS alerts for various events on crossing limits, to multiple mobile numbers. The cost include only for access to server/ application and it does not include the cost of required hardware. The cost of hardware will be charged separately but the cost of running the services is included. For access to Motor controller/ Valve Controller - For 12 months 58 Supply, Installation, Testing & Commissioning of Float Valve/ Ball Cock: Providing fixing and installation of PTMT Float Valve with powder coated aluminium rod & L.P./ H.P.H.D. plastic ball in Existing Water tanks including cutting/ threading existing water supply line and providing and fixing of required GI/CPVC/UPVC fittings (Elbow, Socket, Bush, reducer) complete. - 25mm dia NB 59 Supply, Installation, Testing & Commissioning of Aquabrims Water Level Controller Unit including Fixing of Controller, Transmitter and other Accessories within the premises.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
41.
Educational and Research Institute #10265178 Price Bid
Tender For Clean Room; 1 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-50 mm thick PPGI/ PPGIWall panel for coloumn 2 PARTITION PANELING WORKS Double skin modular wall panel system made of 0.6 mm thick Precoatedsheet on both sides with PUF as infill of density 40 ± 2 kg/m3, Double tongue and groove joints as per standard manufacturing specification.-100 mm thick PPGI/ PPGIWall panel for coloumn 3 Wall paneling of PPGI/PPGI of 100 mm thick with 40 mm of glass wool panel, Desnity 100Kg.M3, Non combustable, Penling color as per architect choice. With necessary double door of equal size as per site condition. Fittings complete all. Panel of three side with roof necessary duct cut otu with proper seal to be done as per site for sound insulation. 4 Panel Thickness : 100 mm PPGI/PPGI Wall raiser ( 700 width x depth less than 80 mm) 5 WALKABLE CEILING PANELS PPGI/PPGI -Double skin modular clean room walkable ceiling panels made With 0.6 mm Pre coated sheets on both side with PUF as infill of density of 40 ± 2 Kgs/m3. -50 mm thick PPGI/ PPGI CEILING PANELS 6 CLEANROOM DOORS -50mm thick flush frame made of 1.2 mm thick GPSP powder coated sheet, 0.8 mm thick PU powder coated GPSP sheet with HONEY COMB KRAFT PAPER as infill of 46mm thk shutter suitable for 50mm thk frame, including all the accessories like double glazed veiw glass, hardwares like push plate, kick plate, non concealed door closure. SS D handle, SS ball bearing butt hinges, both side key operated lock & key. Concealed drop seal per leaf and concealed flushbolt for double leaf door etc.- Single Leaf Door - Size 1000 x2100 mm 7 Double Leaf door size 1800mm x 2100 mm 8 Double Leaf door size 2000mm x 2100 mm 9 VIEW PANELS -Double glazed view 5 mm toughned glass with flush design, 50 mm thick flush view panel made of 1 mm thick GI frame with PUF as infill in- between the frame. 10 Coving & Corners -Male & Female R-70 Powder coated coving 11 2D / 3D internal powder coated corner coves 12 External 90 degree powder coated coving 13 Bottom Track for panel 14 Silicon sealent for panel to panel joint 15 Supply, installation of Air shower- Microflow make MFD-AS -1200 Model. Inner dimension- 900x1220x1950 (H), Over Dimension of -1800x1320x2200(H), Cabinet, Platform Stainless Steel-304, of 1 person capacity, GI Powder coated with flush double glazing , hardware like door closure, D handle, ball bearing butt hinches door with vision panel, pre filter - flange type of 90% efficiency, pressure drop -6 to 8 mm, Hepa filter Box type, 00.007 % efficiency, pressure drop of 25 mm of W.c, Adjustablke nozzle of 30mm, As per manufacuter specification ,Control motor by DOL starter, doors by electronmahnectic inter locking, Overload protection, thermal relay,Emergency off- Push button. complete all. consider Micro flow 16 Design , supply, providing of ESD MAT flooring of Homogeneous composition with block conductive layer sandwhich between two antistatic layers. Of BS 2050 /1978IS 3462 /1986 Governing specification. Thickness of the materials 2 mm +/-0.1mm( 0.5mm sandwhich conductive layer), Electrical propertie : Surface resistivity 108 -1010ohms/sq. Decay time: Less than 2 seconds. including copper strip below mat to connec the earth bus complete all. with an thermo welding process complete all. 17 Panels as per technical specifications & schematic diagram. 18 Supply, Installation, Testing and Commissioning of Indoor typeLTSwitchboards, Floor mounting type, Bottom/Top entry. Refer enclosed SLD.Enclosure: Compartmentalized Single front CRCA (Cold rolled Cold Annealed sheet steel) Doors:2mm Body:2mm Gland:3mm covers and partitions:1.6mmIP class for Indoor/IP55 with weather proof enclosure for outdoor Bus bars: Electrolytic grade conductivity as per standard IS 5082Bus bar Material: As per SLD Bus bar joints: Shrouded/TinnedProtection releases: As per SLD (Adjustable over current & short circuit unless otherwise specified)Ics=Icu for all breakersUtilization category: All MCCB/ACBs shall be Cat: A except ACBs for Ltg & raw power input distribution panel shall be with Cat: FORM 4B Loovers: Busbar chamber shall have louvers with fine mesh insideShade: Epoxy powder coated RAL 7032Design: Modular type Cable entry: As per site conditionBus bar insulation: Aluminum bus bars shall be bare with color coding at the ends/Copper shall be bare with color coding at the ends/For Humidified areas the copper bus bars shall be coated with tin. 19 Note: The Panel shall be fully as per the requirement of Electrical Inspectorate/ EB authorities. Auxilliary contactor to be provided along with auto-manual switch where ever required.All MCCB Breakers both Incoming & Outgoing shall have LEDON / OFF / TRIPindications without fail. CTs shall be with dual ratioand cast resin type only. All doors to have double rubber gasket with shutter assembly & door seating frame.All AC feeders will have time delays of 0-60 Seconds. MCCBsof 250A Above willbemicroprocessor basedonly. Any panel if more than 1.5m width should be made in parts each part not exceeding 1.5m. The current density for Aluminum busbars shall be 0.8 only.All UPS outgoing panels shall haveneutral busbars double the size of phase. All MCCBs shall have plug setting from (40or50)-100%.All Lighting / RP and Lift panels shall have ELR for incomer of Prok. Dvs. Make only. All test certificates must be provided immediately after commissioning.SAFETY CERTIFICATE FOR THE PANELS SHALL BE PRODUCED FROM CEIG. All meters shall beDigitaltype only. FRLS PVC copper wires shall be used for control wiring 20 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :Main panelsupply, installation, Testing and Commissioning of Main Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 315A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –315/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-315A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 5 Nos - 63A TPN MCCB, 1 Nos - 40A TPN MCCB, 2 Nos-250A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 400A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 V Construction :Single Front with Top Cable EntryDimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout. 21 The MCCB should be current limiting type with trip time of less than 10 msec under short circuit conditions. The MCCB should be either 3 or 4 poles as specified in BOQ. MCCB shall comply with the requirements of the relevant standards IS13947 – Part 2/IEC 60947-2 and should have test certificates for Breaking capacities from independent test authorities CPRI / ERDA or any accredited international lab.Important Note : - Breaker discrimination study need to carried out & Breaker/Breaker frames need to be selected accordingly. Switch Board Designation :CLEAN ROOM PANELsupply, installation, Testing and Commissioning of Clean Room Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485.INCOMER:- 1 Nos – 250A TM 4P MCCB TPN 36 KA with FD KIT. 1 Set –250/5A CT CL 2, 15VA for metering with MFM Single Source, 1 Nos. –Digital type Ammeter (0-250A) with selector switch, 1 Nos. –Digital typeVoltmeter (0-500V) with selector switch, 1 Sets –LED type RYB indication lamp with control MCBs, 1 Sets –LED type ON/OFF indication lamp with control MCBs. OUTGOING:- 2 Nos - 125A TPN MCCB, 3 Nos-40A TPN MCCB, 3 Nos-25A TPN MCB,Spare Refer SLDBUS BAR RATING:One set: 250A3phase + Neutral 35KA for 1 sec. AL. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus.Voltage :415 V Construction :Single Front with Top Cable Entry Dimension : To be assessed by ContractorLocation : Refer Electrical Equipment Layout 22 Servo Stablizer 80Kva 3PHASE STABILIZERSupply and Fixing Three phase full automatic compensation AC voltage servo stabilizer is 80kVA capacity, 3 phase 4-line with 175V-265V (phase voltage) / 304V-456V (line voltage) input voltage range, the default output is 3 phase 380V, other voltages are customizable. ±15% tolerance of input range for output voltage above 380V and ±20% of that below 380V. 23 Switch Board Designation : UPS OUTGOING PANELsupply, installation, Testing and Commissioning of Ground Floor Power Panel floor mounting type, dust and vermin proof by construction of 14 SG CRCA sheets with bolted construction, cable entry & exit provision for bottom/top, powder coated panel, surge arrester (1No) as per tender technical specification and the details mentioned below.METERS with RS 485. INCOMER:- 1 Nos – 125A TM TP+2N MCCB 25 KA. 1 Sets –LED type RYB indication lamp with control MCBs,1 Sets –LED type ON/OFF indication lamp with control MCBs.OUTGOING:- 6 Nos - 40A 10 kA TP+2N MCB, Spare Refer SLD BUS BAR RATING:One set: 125A3phase + Double Neutral 25KA for 1 sec. Cu. bus bars with colour coated heat shrinkable PVC sleeves with DMC/SMC bus bar supports and suitable earth bus. Voltage :415 VConstruction :Single Front with Top Cable EntryDimension : To be assessed by Contractor.Location : Refer Electrical Equipment Layout 24 DISTRIBUTION BOARDSLDB - 8 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 8way MCB DB comprising of the following :INCOMER: 40A TPN MCB 10kA with all necessary connected accessories – 1No.32A DPMCB WITH 32A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 32A DP RCBO outgoing consist of 8nos.610 A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 25 UPS - 12 WAY (7 segment) MCB INCOMER DB: Supply, fixing, testing and commissioning of the double door type compartmental Phase segregated 12way MCB DB comprising of the following :INCOMER: 40A 4P MCB 10kA with all necessary connected accessories – 1No.40A DPMCB WITH 40A DPRCBO 30 mA – 3 Nos. as individual phase incomers OUTGOING:Each 40A DP RCBO outgoing consist of 12nos.1620A 10KASP MCB (C-Curve) in a separate compartment with necessary phase segregation as required by the Electrical Inspectorate.With necessary tinned copper busbars, interconnections, separate earth bus, separate neutral bus for each phases.The board shall be powder coated type fixed with concealed system in wall/ fixed in column.The rate shall include necessary connected civil works like chipping, rough plastering etc. 26 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided.,4 Core 150 Sq.mm XLPE Aluminum armored Cable 27 4 Core 120 Sq.mm XLPE Aluminum armored Cable 28 4 Core 95 Sq.mm XLPE Aluminum armored Cable 29 4 Core 25 Sq.mm XLPE Aluminum armored Cable 30 4 Core 16 Sq.mm XLPE Aluminum armored Cable 31 4 Core 6 Sq.mm XLPE Copper armored Cable 32 4 Core 4 Sq.mm XLPE Copper armored Cable 33 3 Core 6 Sq.mm PVC Copper armored Cable 34 3 Core 2.5 Sq.mm PVC Copper Cable 35 3 Core 1.5 Sq.mm PVC Copper Cable 36 1 Core 25 Sq.mm PVC Copper armored Cable 37 1 Core 1.5 Sq.mm PVC Copper Cable 38 1 Core 2.5 Sq.mm PVC Copper Cable 39 LT CABLES & ENDTERMINATIONS For all items in the rate includes necessary connected minor civil works if required and necessary supports as required at site. No extra payment will be made for the sameSupply and Laying of following size PVC/XLPE (FR-LS) insulated outer sheathed (1100 V grade) copper/Aluminum armored & un armored conductor cable partly laid incable tray and partly laid in wall/ ceiling with suitable individual clamps at every 1 mtr interval . Cable tray will be measured and paid separately. Cable Tags to be provided at every 50mtr interval and at either side of the bends.Only for Lighting cables cable tie will be permitted other cables clamps to be provided., 4 Core 50 Sq.mm XLPE Aluminum armored Cable 40 4 Core 35 Sq.mm XLPE Aluminum armored Cable 41 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits consider Dowells / Comet (copper sockets for copper cables and Alu. Sockets for alum. Cable)4 Core 150 Sq.mm XLPE Aluminum armored Cable. 42 4 Core 120 Sq.mm XLPE Aluminum armored Cable 43 4 Core 95 Sq.mm XLPE Aluminum armored Cable 44 4 Core 25 Sq.mm XLPE Aluminum armored Cable 45 4 Core 16 Sq.mm XLPE Aluminum armored Cable 46 4 Core 6 Sq.mm XLPE Copper armored Cable 47 4 Core 4 Sq.mm XLPE Copper armored Cable 48 3 Core 6 Sq.mm PVC Copper armored Cable 49 1 Core 25 Sq.mm PVC Copper armored Cable 50 Supply, Fixing of Termination kit(Glands & lugs) of the following size cables with suitable double compression glands with suitable crimping socket. The rate shall be inclusive of Gland Earthing Plate Prefabricated as per Gland Size with provision for connecting Cu.SWG and Cable Tags should be engraved type for all I/C,O.G& lighting Circuits (copper sockets for copper cables and Alu. Sockets for alum. Cable) 4 Core 50 Sq.mm XLPE Aluminum armored Cable 51 4 Core 35 Sq.mm XLPE Aluminum armored Cable 52 WIRING - CIRCUIT CUM POINT WIRINGThe rates for all point wiring items shall also includesupplying and fixing of the Conduits,conduitspecials, bushes and other fittings,Approved GI saddles and grouting thesame for exposed conduit work,2 mm thick Outlet boxes and junction box,All fixing accessories such as clips, brass screws etc,Allwork & materials necessary for wiring a point circuit of anylengthfromtheFinal DistributionBoardto connectorviaswitch and shall include thecircuitwiring also except where identified. 53 Primary Light / Fan Point Wiring: Supply, wiring, connecting& commissioning of 3Runs1.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition including supplying and fixing of modular 6A One way switch along with molded front plate in GI anodized manufacturers mounting box-Flat switches with indication fixed flush with the wall complete with all accessories including 3 plate ceiling rose.NOTE: Above false ceiling when it is open wiring it should be of MS conduit 54 Lighting Circuit Mains: Supply and laying of 3 Runs2.5 Sq.mm. (Ph, Neutral & Earth) PVC insulated multistrandedHR-FRLSH-LFcopper wires in 1.8mm thick MS conduits fixed on ceiling partly and1.8 mm thick PVC conduit concealed in the wall partly with necessary clamps, screws, etc., as required as per the site condition., from LDB to Lighting Switch Boards and MCB to First Light Point. 55 SOCKETS Supply, Installation, testing and commissioning of 1nos 6/16AUniversal switched socket( UPS) and 1nos 16A switches and withmolded frontplate, GIanodized enclosure, and mounting box in the wall(concealed/open)andother associated accessories including chasing embeddingrough plastering as required as per the site conditions forpower points. 56 Supply & Laying of 2R 4 sq.mm and 1R 2.5 Sq.mm. PVC insulated FRLS multistranded cu wires 20mm dia 2 mm thick MS conduit with all accessories as reqd. (From DB to 6/16A Power Sockets / 20A Metal clad plug & sockets.). 57 Cat6 RJ45-RJ45 UTP Patch Cords, color matched, Yellow - Workstation end, 7 ft, Data-1 58 2-port Faceplate 59 4-pair, Cat6 UTP Cable, roll of 305m, LSZH 60 Cat6 24-port Unloaded Angled Jack Panel, 1U 61 Cat6 UTP Information Outlet for Jackpanel end 62 LIGHT FITTINGSSupply, Fixing, testing and commissioning of square type Recessed mounted LED luminaire 42 W (W)600x600 with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 63 EARTHING Supply, installing, testing and commissioning of maintenance free earth pipe of 3 mtr long T50 mm dia dual G.I pipe with flat buried in ground with back filling compound in an earth pit of 450 x 450 x 3000mm mixed with sand in alternate layers of 150mm each up to a height of 2550mm from bottom. The pipe shall have provision for connecting earth flats / wires. A masonry structure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 64 Supply, Installation, testing and commissioning of earth plate of size 600 x 600 x 3mmcopper plate earth electrode at a depth 3000 mm in an earth pit of 450 x 450 x 350mm filled with salt and charcoal mixed with sand in alternate layers of 150mm each up to a height of 3000mm from bottom. Two copper flats of size 25 x 3 mm shall be braced to this copper plate throughout the overlapping length with the copper plate and brought to the surface of the earth pit. This plate shall have provision for connecting wires or flats as the case may be. A suitable size of 25/ 38mm dia GI pipe shall be provided up to bottom of the earth pit. This GI pipe shall have provision for watering through a funnel. A masonrystructure of wall thickness of not less than 230mm shall be constructed to a depth of 450mm and heavy duty SFRC cover shall be used to cover the pit. 65 Supply andlaying of following copper flats laid in open / buried underground / concealed manner withnecessary clamps, SMC insulators, screws, interlinks etc. for earthing . 50X10 mm GI . Flat for panel cable tray Body earthing 66 25X6mm GI . Flat for panel cable tray Body earthing 67 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required 68 8 SWG Cu. Wire for DBs earthing 69 25X6mm Cu Flat forearthing 70 SECTION-A : UPS / INVERTER SYSTEMSupply, installation, testing and commissioning of 3 kVA Inverter system with single phase input and single phase output with Battery stand complete all necessary accessories and tools as required as per site condition. Make : Schenider , Socomec 71 Supply, installation, testing and commissioning of 3x25KVAonline modular UPS System Three phase input & Three phase output, 50 Hz, 415 V complete. The UPS shall be microproccesor based online with IGBT based convertors (Rectifier & Inverter) and with automatic static by pass.The UPS system shall be provided with SMF batteries (including all the necessary accessories like racks/cabinets, interconnecting links/cables, battery circuit breaker etc.) with 20 minutes back up for each UPS, and communication interface. Quoted rates should be inclusive of Base Frame for the UPS with height of 300/450mm, Load testing (resistive load bank) for four hours/UPS with all necessary items. Supply, Installation testing and commissioning of 1No. of 3 Phase 75KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Supply, Installation testing and commissioning of batteries for 30 mins back up at 75KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between battery bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery Rack for the above said batteries with all required accessories. (battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 60KVA load) 72 Supply, Lifitng , Positioning , Installation, Testing and Commissioning Air cooled Inverter modular Chiller with Dual Circuit , EEV Precise Electronic Expansion valve, High efficiency PlateHeat Exchanger stainless steel plate, low water pressure drop, Smart control with touch screen for heating and cooling system, High Precision stepless energy modulation trane variable frequency unit, High efficiency fan design, Refrigerant R410A, Cooling capacity 130KW, Power input -38.1, Cooling 7DegreeC / 12 Degree C, COP(AHRI)- 3.41, IPLV-4.81, Compressor -2 Nos, Air flow- 23500x2 Nos, Water flow rate- 22.4 Cum/Hr consider Trane., Blue star, Samsung with necessary control panel isolator spring, complete all. 73 CHILLED WATER Primary PUMPS Supply and install of Design envelope close coupled vertical in-line pump in-built VFD with logic controller. Series Design Envelope Sensorless The pumps shall be radially split, single stage centrifugal type with Bronze fitted casing with equal size suction and discharge flanges and having separate tapped flush line and pressure gauge connections,dynamically balanced Bronze impeller, stainless steel shaft lower carbon throttle bushing, outside balanced type mechanical seal with carbon rotating face, Silicone carbide stationary seat Viton secondary seal.The pump motor shall be suitable for 415V+/- 10% Volts, 50 +/- 5% Hz, +/- 10% combined voltage and frequency variation, 3 phase AC power supply. The squirrel cage induction type, P base with TEFC enclosure ansd shall be connected the pump through a high tensile Aluminum slit type spacercoupling to permit servicing of the mechanical seal without disturbing pump, motor or electrical wiringconsiderKSB, Armstorng, Grundfos. Coupling shall be protected by a motor. Flow Rate GPM 100( 2 Working + 1 Standby ) of 32m head. 74 CHILLD WATER SYSTEM AHU Supply, Installation, Testing and Commissioning of vertical floor mounted double Skin AHUs Withmm Sand witched PUF Insulation,top discharge Fan with TEFCmotor, 12 row chilled water coil,pre filter section with filters of 90% efficiency down to 10 u,Limit Switch, Emergency Light, Guard for Inspection Door, Commissioning filters set, outlet damper, etc. of the following capacities with VFD starter panel complete all. including vibration pad etc.Extruded Aluminum Aero foil blade low leakage manual Fresh air damper. Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Pre Filter Section Flange type washable pre filter 10 micron EU4 Grade at Fresh air inlet. Cooling Coil Section8 Row Deep CHW Type coil (Cu Tube & Al fins). To achieve the 22 Degree If any changes coil row to be increased. SS 304 Insulated drain pan with Nitrile Rubber Insulation. BLOWER SECTION EC Fan top dischargeBLEED FILTER SECTION Flange type washable bleed filter 3 micron EU7 Grade at Bleed air outlet with Extruded Aluminum Aero foil blade low leakge manual bleed air damper.FINE FILTER SECTION . Flange Type washable Fine filter 3 micron EU7 Grade with frame. consider CVR Aircon, Air Prism tech, Thermoflex SUPPLY SECTION WITHExtruded Aluminum Aero foil manual volume control damper at supply & Return air outletDuct mounted heater .Magnehelic gauges for measuring differential pressure across AHU filters. Silicon tubes, necessary fixing accessories , screws etc. To avoid vibration on floor vibration isolation should be provided. classified area- 100000 class- 22 degree c , 50% RHAHU Capacity - 8000 cfm Fan static pressure in mm of wc-100Cooling capacity - 13.0 TR 75 Duct mounted heaters Supply, Installation, testing and commissioning of Duct mounted heaters with thyristor control. Cost shall be including of control panel with necessary temperature and RH sensor to control the heater complete all. Etc.-20 KW heaters( Can be spited as per required) for each units 76 AIR CURTAINSAir Curtains with wall mounted type, robust construction, powder coated finish, Aluminum impellers with low noise forward curved blades, adjustable louvers, vibration free operation, pre-lubricated both side sealed ball bearings for smooth running of Air curtain. The Air curtains are should be interlocked with door limit switch.Size: ( 2000Lx300Dx300H) 77 Size: ( 1000Lx300Dx300H ) 78 FRESH AIR UNITS Supply & Installation of Modular type Floor mounted Double skin FRESH AIR FILTER MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panel with 0.63mm GI inner & 0.63mm pre coated GI outer skin. It comprising of filters section with flange type 20 micron filters down to 80% efficiency, consider Kruger ,Greenheck, Carryaire.KRUGER NICOTHRA, higher quality DIDW BLOWER with CG /Higher make non FLP IE-3 motor. Aluminum aero foil design volume control damper with operating knob handle.-5000 CFM. 79 VENTILATION AIR UNITSSupply & Installation of Modular type Floor Mounted Double skin ventilation AIR FAN MODULES made of 25+/-2 puf (40±2 KG CFC FREE PUFFF) insulated panels with 0.63mm GI inner & 0.63mm pre coated GI outer skin. KRUGER/NICOTHRA / Higher Quality MAKE DIDW BLOWER with CG /Higher Quality make non FLP IE-3 motor, consider Kruger ,Greenheck, Carryaire.Aluminum aero foil design volume control damper with operating knob handle.-4000 CFM. 80 AIR DISTRIBUTION SYSTEM Supply, installing, testing and commissioning of following items as specified and shown on the drawing for complete and satisfactory operation and control and to local authorities approval. Air distribution system consists of factory fabricated sheet metal rectangular ducting with reinforcement / stiffeners (manufactured through computer aided machine which has automatic provision for plasma cutting for the profiles and for auto folding) with TDF /TDC flanges, nuts and bolts, corners, clipsetc with suspenders with Gripple /Zip Clip cables, complete as per specification. consider Cosmic , Western air duct , Sreevinus The ducts shall be fabricated as per SMACNA standards. 18G thick GSS ducting– factory fabricated . 81 20G thick GSS ducting – factory fabricated 82 22G thick GSS ducting – factory fabricated 83 24G thick GSS ducting – factory fabricated 84 Supply, fabricating and erecting structure steel of make TATA/SAIL shall be confirm to IS:2062 along with test certificate as per specification including transporting, straightening, cleaning, fabricating and erecting various structures in position for ducting support, applying two coats of zinc chromate primer of ICI, Asain make or equivalent, with rubber gasket between support & duct as per specifications and drawings and as directed by the Engineer-in-Charge client /consultant. 85 Supply and erection of Nitrile rubber Insulation of Supply air duct with 19mm thick Armasound cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification.- Return air duct 86 Supply and erection of Nitrile rubberInsulation of supply air duct with13mm thick, FM approved cross linked polyethylene foamed insulationwith aluminum foil thickness class-1, temperature range from -10ºC to +85ºC, Class 1 fire category and as per specification. 87 Supply and fixing of Spigot damper shall be installed from take off collar to diffuser plelum boxes(low leakage) consider Cosmic, Western air duct , Sreevinus,made out of 1.6mm galvanized sheet steel frame and blades of 1.0mm galvanized steel with suitable links. 250mm dia 88 100mm dia 89 Supply and installation of Flexible duct connections between main duct and diffuser plenums, Consider Cosmic , Western air duct , Sreevinus, shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports.250mm dia. 90 Supply and installation of Powder coated extruded Aluminum linear grills for supply air grills Consider Cosmic , Western air duct , Sreevinus .The rate shall inclusive of Aluminum with collar damper, necessary fixing and supporting arrangement for the grilles. 91 Supply and installation of Powder coated extruded Aluminum linear grills for return air grills consider Cosmic , Western air duct , Sreevinus.The rate shall inclusive of Aluminum with out collar damper, necessary fixing and supporting arrangement for the grilles. 92 Supply and installation of GI volume controldamper, (low leakage) made out of 1.4mm thick galvanized sheet steel frame and opposed blades of 1.4mm galvanized steel with suitable links, handles, levers and quadrants for manual control of volume of air flow and for proper balancing of air distribution system consider Cosmic , Western air duct , Sreevinus. Rectangular type VCD -for future provision classified room damper to be provided. 93 Supply, installation of 4 way diffusers for Return air of neck size 550x550 94 SupplyFabrication , and erectionofDouble canvas connection made out of fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc 95 Terminal HEPA Filter Module (For ISO-7 & ISO-8 areas) Terminal HEPA filter module of GI powder coated sheet construction with volume control damper (shall be operated from the clean room), DOP test port, Mini-pleat HEPA filters with 99.97% efficiency, swirl type air diffusers at terminal level .HEPA Filter Size: 600 x 600mm / each up to 1000cfm 96 Supply and Fixing -UL 555 listed Moto raisedFire damper with 300mm sleeveDampers G.I.16G. The fire dampers of atleast 2 Hours fire rating with angle frame (on both sides of wall) and multi leaf dampers out of 18G with cross bush.The dampers to signal accidental closure through built in limit switch. Include for hard wiring between starter and Limit switch, including necessary Bolt, nuts & supports. 97 Supply, installation, testing and commissioning with belmo activator with necessary cables , control panel, to connect with AHU starter panel to control the fire mode. 98 Supply, laying & termination of 3C x 1.5Sq.mm power cabling between 230V single phase power socket to Actuator with necessary supports & clamps. 99 Supply & fixing of 16G M.S.Conduit for cable laid between actuator to AHU panel 100 MS PIPING Interconnecting MS with c class pipe work duly insulated with elastomeric nitrile rubber typetubular insulation as per specifications .All piping inside the room shall be properly supported with hanger.MS supports for piping & cables, using angles, channels, Tees, flats, etc should be considered as part of scope.All MS supports shall be given a coat of red-oxide primer and two coats of synthetic enamel paint of approved colour. 100 mm dia 101 80 mm dia 102 65 mm dia 103 Supply, installation of nitrile rubber insulation with Aluminum cladding of 26 Gauge complete all. 104 DUAL PLATE CHECK VALVES :( NRV )Supply, installation, testing & commissioning ofdual plate check valves, wafer type sleep-on construction.The valve bodyshall be cast iron as per IS 210 Gr. FG 220. The valve disk shall be aluminum - bronze plate, SS 316 inch pins & pins and springs rubber seal and should be rated for a pressure rating of ANSI 150and complete with with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification. 50 mm dia 105 Y-TYPE STRAINER :Supply, Installation, Testing and Commissioning ofY – Strainers CI fabricatedcomplete with SS - 304 perforated sheet basket having 3 mm perforated hole, PN-16 pressure rating body,Tabel-E flanged endsand duly insulated as per piping and specs.65 mm dia 106 BUTTERFLY VALVES : Supply, installation, testing & commissioning of Wafer type Butterfly valves with PN 16 pressure rating, Cast iron body , EPDM Seal, Stainless Steel 416 Shaft material, Nylon coated ductile iron lever lock handle and confirming to IS:13095, complete with companion slip on flanges as per BS10, nuts, bolts and gaskets as required.with 30 mm thick PUFwithAluminum claddingthickness of 22G.50mm Dia 107 65mm Dia 108 PRESSURE INDIPENDENT BALANCING AND CONTROL VALVE - PIBCV:Supply, Installation, Testing & CommissioningofPressure independent balancing cum flow control valve PN16, Cast Iron body with flanged end with modulating type electronic actuator, solid state temperature sensor and controller, power and control wiring, power supply unit etc. consider Donfos / Honeywell / Siemens.The valve actuator and sensor shall be IBMS compatible. with 30 mm thick PUFwithAluminum claddingthickness of 22G as per specification 80 mm dia . 109 PRESSURE GAUGES : Supply, Installation, Testing and Commissioning ofdial type pressure gauges made of Stainless steel with range selected so that normal operation is near to middle of the scale, consider Wari/ H guru.Syphons and cocks to be provided along with SS snubber. 110 DIAL TYPE THERMOMETERS : Supply, Installation, Testing and Commissioning ofdial type Dial type Thermometers of 100 mm dia shall be of mercury in steel type with range suitable for the temperature services.It should be installed in the thermowells as explained in the tender specifications.. 111 DRAIN VALVE :Supply, Installation, Testing and Commissioning of Ball Valve for drain with insulation. Nipple and dummy to be fixed after the gate valve of size 25 mm NB. 112 AUTO AIR VENT VALVES : Auto Air valves to beprovided at all high points in the piping system for venting. Valves shall be of the double float type with G.Mbody, vulcanite balls, rubber seating, etc. of 20 mm NB and shall be associated with an equal size gate valve with rising spindle. 113 Ball VALVES : G.Mbody, vulcanite balls, rubber seating, etc. offollowing size inmm NB and shall be associated50mm Dia. 114 25mm Dia 115 Leakage test for DuctingAll medium and high pressure ductwork at classified and unclassified area shall be seal class A and be leak tested as per IS-655.2006 leak test method Class-6 (rectangular duct) & soap solution.This has to be carried out through third party agency not the vendor. 116 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.1% duct vol/min at 1000 Pa (4 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 117 Acceptance criteria for all classified area ducting (ISO-7): Rate of air leakage not to exceed 0.2% duct vol/min at 500 Pa (2 in. w.g.) minimum test pressure. All instruments should be appropriately calibrated by an accredited laboratory. 118 VALIDATION & DOCUMENTATION Validation including DQ, IQ, OQ & PQ protocols and certificates of all manufactured items, duct. Validation should include minimum following tests:- i) Air quantity, Air flow velocity and ACPH calculation ii) Pressure balancing iii) Filter leak test iv) Particle count test v) Recovery test vi) Air flow pattern vii) Temperature & RH monitoring for 3 days by data logger. Validation should be conduct for all three seasons (Three times / year) Immediately after commissioning, one validation after 6 months of system running and final validation at the end of guarantee period.Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 119 Testing, adjusting, balancing, reporting and documentation of air distribution system carroed out through a third party commissioning agent. 120 FIRE EXITINGUISGHERS:- Portable ceiling mounted clean agent fire extinguishers manufactured as per IS with ISI marked suitable for wall mounting / floor mounting / trolley types with all accessories. -10kg with necessary ceiling mounted brackets up to the ceiling height maximum of 1200mm as per site condition, consider Safex, Ceasfire, Minimax. 121 4.5 kg. capacity carbon di-oxide fire extinguishers with wall mounting bracket 122 SITC OF SIGNAGE SYSTEM -FIRE EXIT - SINGLE SIDE 123 DIRECTIONAL EMERGENCY EXIT (AUTOGLOW SIGNAGE) - DOUBLE SIDE Make : Prolight 124 EXTINGUISHER Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300) - double side 125 MCP Signages - Autoglow, with suspension chains (Autoglo signages, size 150 x 300 - double side 126 Fire Evacuation Route Map as per following specification Evacuation plan shall be glow in dark. A3 size with 5mm thick rear & 3mm thick front acrylic cover including wall mount supports. 127 ADDRESSABLE FIRE ALRM SYSTEM -Supply, Installation, testing & commissioning of 2 Loop Addressable Fire Alarm Control Panel - Total 640 Devices per loop 159 detectors/ 159 modular combination, consider Edwards Honeywell, Ravell 128 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector above with necessary base box complete all. 129 Supply, Installation, Testing and Commissioning ofAnalog Addressable Photo Electric Smoke Detector below with necessary complete all. 130 Supply, Installation, Testing and Commissioning ofResponse Indicators. 131 Supply, Installation, Testing and Commissioning of Addressable Manual Pull Station . 132 Supply, Installation, Testing and Commissioning ofSounder Cum Strobe . 133 Supply, Installation, Testing and Commissioning ofAddressable Short Circuit Isolator Module 134 Supply, Installation, Testing and Commissioning ofAddressable Control Module. 135 Supply, Installation, Testing and Commissioning ofAddressable Monitor Module . 136 Supply, Installation, Testing and Commissioning ofJunction Box. 137 Supply & Laying of 2C X 1.5 Sq.mm Shielded Copper armored Cable, including clamps, fixing accessories complete all. 138 Supply & Laying of 4C X 1.5 Sq.mm Shielded Copper armored Cable,including clamps, fixing accessories complete all. 139 Supply, Installation, Testing and Commissioning of power supply unit 140 4 reader controller with cabinet and power supply backup. as per specification. 141 Multitech T15 reader 142 Supply, Installation, Testing and Commissioning of surface / flush mounted (as required at site) Magnetic Contact (Door position sensor)for access controlled doors as per the tender specification. 143 Supply, Installation, Testing and Commissioning of exit switch & accessories with 2.5mm thick SS front plateas per specification suitable for mounting on metal surface/metal frames or wooden frames wall or as required based on site conditions including all accessories. 144 Supply, Installation, Testing and Commissioning of Buzzerfor access controlleddoors as specified inthe Tender Specifications 145 Supply installation, testing, commissioning of EDR (EMERGENCY BREAK GLASS) 146 Supply andlaying of 4 core 1.0 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller to Lock & door position sensors, Buzzer,BGU,Pushbutton as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 147 Supply andlaying of 8 corex 1 Sq mm Un armored Shielded FRLS, Multistranded Copper Conductor, PVC sheathed Cable for connecting controller toreaders as per the tender specificationsRate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. 148 Supply andlaying of 2 corex 1 Sq mm Un armored Shielded FRLS, Multistanded Copper Conductor, PVC sheathed Cable Rate shall inclusive of 2mm thick suitable dia FRLS PVC conduits with ,JBs in wall, columns, ceiling etc., including associated civil works. (conduits & cables - blue color) 149 Supply andlaying of MS Powder coated Trunking 150 x 50 mm x 2mm with cover &fixing suppports etc as required 150 Supply andlaying ofCAT6 cable in PVC FRLS Conduits (this item inclusive of necessary patch cords,I/Os& terminations ) - for connecting Controller/Reader with IP switch 151 Supply, Installation, Testing and Commissioning ofLocal scare alarm with required wiring between LCA & door contacts (For fire exit doors). 152 VIDEO SERVILANCE SYSTEM - Supply, installation, testing and commissinoning of, 5 Megapixel low light power over -coax(PoC),Dome type HD Output, up to 720 P resolution, Low illumination, 3.6mm lenss, tru day / Night , OSD menu,Smart IR, Up to 40 m IR Distance, necessary suports, complete all.consider Hivision, Dohua, Honeywell. 153 Supply & Installation of Network Video Recorder with 8 HDDs Storage Capacity, 32-Channel Video, Client Licenses, & supports H.264 Compression, Real time Surveillance, The data should be stored 90 days (Hard disk to calculation report to be submitted). -8 TBHard disk which ever is to be check 154 Supply, installation, testing and commissioning of 42 Inches HD LED Television (TV)/Moniterwith Resolution: 1366 x 768 Pixels and 2 HDMI out put. With necessary power cable complete all. 155 Supply, installation , testing and commissioning of PYE swith ( Power on Ethernet) with necessary arrangement complete all. 156 Supply, installation of Cat 6 cable with 25 mm PVC conduit with necessary L, bend, flexible conduit , clamps complete all. 157 Supply and laying of 2Cx 1.0 Sq.mm FRLS cable with suitable accessories etc. 158 Supply and fixing of power supply unit complete all. 159 PLUMBING & SANITARY WORKS: Supply, fixing of 15mm dia Sensor Pillar cock with necessary flanges suitable for under counter wash Basin . Jaquar Make - SNR- CHR 51011 160 INTERNAL WATER SUPPLY -Supply and installation testing and commissioning ofpipe CPCV SDR-11 as per IS 15778including fittings, supports, clamping ,flow indication colour band ,pipe name marking etc complete in all respects. Including wall chasing and finishing the wall in good condition as per original complete all. -20 NB 161 Supply, erection, testing and commissioning of CPVC valve of the following sizes including nipple etc complete in all respects of following sizes. -20 NB 162 Supply, installation of digital type water meter with necessary fixingaccessories complete all. -32 mm dia 163 INTERNAL DRAINAGE SOIL AND WASTE PIPES , INTERNAL- Supplying and laying P.V.C Pipes of 6kg class ofIS:4985 - 2000and P.V.C.Pipe specials of cutting to required length, Erectionpipe specials along with P.V.C.Pipe, Making ring seal couplers to join the pipe and pipe specials. 110mm dia, using internal and external including excavation and complete all. with necessary wall clamps.Internal & External - 110 mm dia pipe -6 kg/cm2 164 75 mm dia pipe - 6 Kg /Cm2 165 50mm dia pipe- 6kg/cm2 166 supply installation of floor drain fabricated as per site condition 167 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 28 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 168 LIGHT FITTINGSSupply, Fixing, testing and commissioning of LED luminaire 20 W Linear Suspended light fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 169 LIGHT FITTINGSSupply, Fixing, testing and commissioning of surface mounted type LED luminaire 15 Wlight fitting with all necessary accessories suitable supports, screws, etc. from ceiling. Local make. As per Architect and consultant approval. As per Architect and consultant approval 170 Supply, Installation testing and commissioning of 1No. of 3 Phase 10 KVA UPS (0.99 IPF & <3% THDi) along with SNMP & Modbus card for the above said combination and all as per the enclosed SLD and specification mentioned above. (The rate shall also be inclusive of Remote display and alarm module for UPS failure notification with required cabling and accessories etc.)Note : Vendor to submit filled compliance for both specification sheet & Data sheet . Supply, Installation testing and commissioning of batterries for 15 mins back up at 10 KVAfull load including neceessary accessories like interconnecting cables between batteries ,interconnecting cables between batterry bank and UPS and all as per technical specification. specification.Note : Vendor to submit Battery calculation sheet with battery catalogue. The rate shall inclusive of suitable battery circuit breaker with enclosure etc. Supply and installation of battery& Rack for the above said batteries with all required accessories. (Each set of battery rack should be suitable to accommodate the batteries which is having 30minutes back up for 10 KVA load). 171 Supply, installation, testing and commissioning of BACNet compatible Ultrasonic BTU meter as per the system requirements for tenant billing. 100 mm dai 172 80 mm dia 173 65 mm dia 174 Supply, Installation, testing and commissioning of Control panel for above BTU meters to control the PIBCV with necessary wiring complete all. 175 Supply, instalaltion of Thermowell of ss as per requirement with insert type temperature sensor complete all. 176 Supply and installation of Flexible duct connections between main duct and diffuser plenums shall be 25mm thick fiber glass pre-insulated, single ply / multiply Aluminum construction and with multiple layers of polyester film glass fiber covered with mechanical lock sheets/ Aluminum laminated jackets-Fire resistant complete with Pre-fabricated and powder coated Aluminum angle frame mounting brackets and supports. 100mm dia 177 Air terminals : Supply & installation of Terminal module of 16/18 G GI powder coated material, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob provision should be bottom. Module size: 680 x 680mm or MFD Std. but Suitable for 610 x 610 x 300 / 150 deep 178 Module size: 540 x 540mm or MFD Std. but Suitable for 450 x 450 x 300 / 150 deep 179 SIZE :450 x 450 x 300 / 150 deep 180 SUPPLY AIR GRILLS : Grill size: 745 x 745 mm or MFD Std. 181 Grill size: 600 x 600 mm or MFD Std. 182 Supply grill for IOT Control air vent system for the cleanroom to monitor and control temperature and RH, via mobile or desktop application, damper with neceeary activator, control cabling, as per client requirement. Including conduit clamps complete all. 183 Supply, installation, testing and commissioning of control panel for the above with necessary controller for automatic and manual both options complete all. 184 RETURN AIR MODULES : Supply & installation of Raiser module of 16/18 G GI powder coatedmaterial, leak proof construction with grill fixing provision, duct connection provision, fixing hold fastener, and . Gear Type Damper operating knob to Control The Air -Grill Module Size : 540 x 540 x150 mm 185 RETURN AIR RISER GRILLS : RETURN/EXHAUST Air RISER mounted module grills made of SS-304 Mirror polished in front (180 grit) in 16 G Perforatedgrills fixing to the Terminal module ( Grills fixing blind bush suitable to M-6, SS-304 doom bolts). SS 304 grill For Raisers (as per drawing) 186 SS 304grill For Grill Modules 187 RETURN AIR RISER FILTERS: Return/ExhaustAir False ceiling mounted Terminal filters made of 16G GI Powder coated filter Box with flange type casing and 10micron down to 90% efficiency. Filter media shall be SNPF [WASHABLE] -700 x 450 x 20 MM 10 Micron filters and control damper (as per dwg) 188 Supply, Installation, Testing & Commissioning of Piping system with SS 316L confirming to ASTM A 269, Internally electropolished to 10 Ra micro-inch surface finish and ends capped, orbitally robotic welded along the circumferance, properly colour coded as per IS standard with following diameterand wall thickness as noted below with flow arrow, service metal band and colour stickers as per IS standards. Approved make: Sandvik/Sumitomo. 8.0 MM for compressed air as per client requirement and layout. 189 Supply, installation, testing and comissioning ofBall Valvewith Ferrule tube fittingsEnd connection-Swage lock Class- 150#Ball construction- Single Piece, Body- SS316LBall - SS 316LApproved Make: Swagelok -8 mm 190 Supply, installation, Calibrated, and commissioning of SS Buordon type pressure gauge with100 mm dial dia, syphone tube, needle valve and the scale range 0-20 bar. 191 Supply, Installation of 40 NB Digital vertex type flow and consumption meter for Compressed air application. Max flow 124 CFM at 8.5 bar. 192 Supply, Installation of following size of GIrubber line Split clamp. - 8.0 MM 193 Supply, Installation ofGI slotted C - Channel 40 x50x40 2mm thick for compressed Air pipe support. 194 Warranty for all the above items.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
42.
Drinking Water Supply and Sanitation #10243543 Price Bid
Supply Installation Testing And Commissioning Of Radar Based Velocity Type Fm At Raw Water Channel For Hcc Clarifiers At Chandrawal Water Works-Ii-Supply, Installation, Testing, Commissioning of velocity based Flow meter (model FL 432) which can measure the flow with product of velocity and level on continues basis to be mounted on open channel system and should simultaneously read both velocity and level to calculate flow/discharge. The system characteristics are :- 1. Non-contact Measurement, low power consumption, small beam angle2. Standard RS 485 Modbus Communication3. Convenient Installation4.Flow velocity and water level output in one.5. Supply voltage: 12 VDC,6. Static Current less than equals to 1 mA (@12V),7. Operating Current less than equals to 100mA (@12V)8. Water level Range: 15m (range optional 30m/45m),9. Water level accuracy 3mm10. water level Resolution: 1mm11. water level radar frequency: 26 GHz12. water level Radar Beam angle: 10 degree13. Flow velocity measurement range: 0.5 - 21m/s14. Flow velocity accuracy: 8.8mm/s15. Flow Velocity Resolution: 1 mm/s16. Flow Velocity Radar Transmission Frequency: 24 GHz17. Flow Velocity Radar Beam Angle: 12 degree X 12 degree18. Water Surface Distance: 0.5 - 35 m19. Operating Temperature: - 35 to 60 degree Celsius20. Storge Temperature: -40 to 60 degree Celsius21. working Humidity less than equals to 95%22. Application occasions: Static water or moving water23. Acquisition Interval: 5s to 24 Hours can be set24. Digital Interface: RS 485MODBUS communication protocol25. Wiring Port: M20* 1.5X2, Make: EIPMake of Flowmeter : ABB/Forbes Marshall/Siemens/DJB approved makes
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
43.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
46.
Educational and Research Institute #10115164 Price Bid
Design, Supply, Installation And Commissioning Of A Cleanroom , A ) Cleanroom Construction 1.0 ) Wall Paneling And Ceiling A ) Progressive Type Double Skin Modular 100 Mm Thick Solid Wall Panel Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , B ) Progressive Type Double Skin Modular 100 Mm Thick Wall Panel With Inbuilt Riser For Return Air Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , C ) Ceiling Wall Panels I ) Grid Type Ceiling System For Class 100The Cleanroom Ceiling Shall Be Formed From A Heavy Duty Aluminium Walkable Extruded T-Grid Ceiling Systems For All Areas. Ceiling Grid Colour Should Match Wall Panel Colour ( Designer White Shade ) . The Ceiling Grid Shall Be Heavy Duty Walkable Inverted T-Grid Ceiling System Of Approx.. 50 Mm Twidth ( Gasket Type Ceiling ) To Be Provided On 600Mm X 1200Mm Hanging Configuration, The System Shall Include Aluminum ( Approx. 50 Mm Wide ) Extrusions, Aluminum Extruded Cross Connector With Hammer Head Bolts And Nuts, M8 Bolt And Matching Square Hanger And Other Standard Accessories. The Grid Should Be Suspended From The Parent Building Roof With Adequate Size Fasteners Etc. For Ensuring Structural Stability Of The Ceiling. Blank Ceiling Panels:50Mm Thick Heavy Duty Walkable Al. Honeycomb Ceiling Blank Panel Of Dimension 1200 Mm X 600Mm X 45 Mm / 50 Mm Thick, Using 45 / 50Mm Thick Aluminum Honeycomb Core Laminated With 0.8 Mm Thick Aluminum Skin On Both Sides, Static Dissipative Finished Of Designer White Shade All Complete. , Ii ) Progressive Type Ceiling For Class 1000 Progressive Type Double Skin Modular 75 Mm Thick Ceiling Wall Panel Made Of 0.8 Mm Thick Powder Coated Sheets On Both Sides With Puf As Infill Of Density 40 ± 2 Kg / M3, Gi Profiles For Reinforcement Along The Periphery With Bottom Aluminium Track, And Necessary Arrangements, All Joints Shall Be Sealed With Cleanroom Compatible Neutral Grade Silicon Sealant. All The Cut-Outs Should Be Covered With Suitable Channels. , D ) Coving: Coving Radius 50 Mm, Moc: Aluminiumcoving Shall Be Installed At :1 ) Wall To Wall 2 ) Wall To Ceiling 3 ) Wall To Flooring , E ) Coving 3D Inner Corner Pieces , F ) Outer Coving , G ) 2D Outer Coving Corner Pieces , H ) Wall Panel Cutouts : All The Necessary Cutouts Made On Wall Panels And Ceiling Will Be Flashed With Gi / Ms Powder Coated C-Channels , I ) Suspended Ceiling Support And Wall Panel Accessories : All The Suspended Ceiling Panels Will Be Supported With 10 / 8 Mm Threaded Rod And Turnbuckle For Easy Level Adjustment At Suitable Locations. Ancillaries Like C-Channel, L-Angles, Required For The Installation Ofm2 Wall & Ceiling Panels , J ) Window Modules Viewing Panels Shall Be Of Double Glazed 5Mm Thick Clear Toughened Glass, Finished With 20Mm Wide Ceramic Borderdimensions: 900X900 In Mm , K ) Cleanroom Doors: The Cleanroom Wall Systems Shall Include All Doors Complete With All Associated Hardware. The Cleanroomdoors Shall Be Of Gi / Ms Powder Coated Construction Of Approximate Size , Flush Configuration, Swing Type, Double Skin. Door Frame Powder Coat Color Must Match With Clean Room Wall System, With Door Closer, Handles, Lock Sets With Option Of One Or Both Side Access, View Glaze Shall Be Of Double Glazed 6Mm Clear Toughened. I ) Cleanroom Single Door-900X2100 In Mm , Ii ) Cleanroom Singleemergency Door-900X2100 In Mm , Iii ) Cleanroom Double Door -1400X2100 In Mm , L ) Fan Filter Modules And Hoodedhepa Filter Modules I ) Hooded Hepa Filter Modules For Class 1000 Hepa Filter Modules: The Cleanroom Ceiling System Shall Include Hepa Filter Ceiling Modules As Indicated On The Drawing. *The Filters Will Be Used As Terminal Air Distribution Device. The Air Supply Plenum Shall Be Connected Directly To A Connecting Collar On The Filter Top With Individual Damper In The Plenum And Flexible Ducts. * The Filters Shall Have H14 Class Filters As Per En1822 With An Efficiency Of 99.95%*The Design Air Velocity Through Filter Shall Be 0.45M / S With Ipd Of 130±5% Pa Or Better.*The Frame Of The Filter Shall Be Of Extruded Anodized Aluminium Construction.*The Filter Media Shall Be Glass Fibre With Hot Melt Separator. *The Filter Shall Have Expanded Sheet Metal Face Guard. The Face Guard Shall Be Powder Coated In Off-White Colour.* The Filter Shall Be Having Endless Polyurethane D-Profile, Liquid Pour To Solid In Extrusion Profile Seal At The Outlet. *All The Filters Shall Be Individually Tested According To En1822 And Computerized Scan Test Report Should Accompany Each Filter.*The Filter Shall Be Held In Place Utilizing ‘Hold Down’ Devices With The Ceiling Grid Using Channel On The Filter Top And T-Bolts In The Ceiling Grid Pressing The Filter Against Ceiling Grid. *All Filter Modules Shall Be Complete With Air Inlet Collar Of 12” Diameter ( Approx. ) . *Top Sheet Should Be Of G.I. / Aluminium Single Piece Drawn With Seamless Neck. In Case, Neck Is Not Seamless, Neck Joint To The Top Sheet Be A Proper Leak Proof Joint And With The Capability Of Supporting A Person Standing On The Top Surface. *Filter Media Shall Be Bonded To Extruded Aluminium Cell Sides.Dimensions :1210 Lx 600 D X 60 Mm Hepa Filter Are Rated 99.97% Efficiency In Removing 0.3? Or Larger Particles. Leak Free In Accordance With Latest I.E.S Recommended Particle.The Filter Media Is Micro Glass Fibre With Poly-String Separator, Sealed To Casing. The Filter Guard Is Provided With Diamond Pattern Expanded Sheet For Protection. , Ii ) Fan Filter Modules With Ulpa Filters For Class 100 : The Fan Filter Units Ffu’S Are Self-Powered Grid Module With Modular Design, To Fitting In Standard T Grid Ceiling. Total Height Is 320Mm. The Fan Filter Module Is U.L Listed And Ce Certified. Ffu Speed Can Vary From 0.2 To .5M / S And Air Flow Rate Vary From 460-760 Cfm. The Sound Level Will Be 55Db’S When Measured From 760Mm Below From Filter Face. The Vibration Level Is 0.9Mils. The Fan Motor Drive Will Be Direct Drive, Forward Curve Centrifugal Type With Sealed Bearing. The Motor Will Have Permanent Split Capacitor Type, Rated For Continuous Operation With Thermal Overload Protection With Two Speed Switch. The Power Requirement Is 230V, 50Hz Single Phase With Maximum Current Of 1.9A With 280Watts Power Input. The Fan / Motor Assembly Is Capable Of Delivering Air At Filter Pressure Of 9Mm To 23Mm Final State. These Ffm Will Have A Speed Controller For Increasing The Speed Of The Motor / Blower From Low, Medium And High. Dimensions :1220 Lx 610 D X 350 Mm H Ffu Material Of Construction : Al Zinc Alloy Hepa Filters Are Rated 99.997% Efficiency In Removing 0.12? Or Larger Particles. Leak Free In Accordance With Latest I.E.S Recommended Particle.The Filter Media Is Micro Glass Fibre With Poly-String Separator, Sealed To Casing. The Filter Guard Is Provided With Diamond Pattern Expanded Sheet For Protection. Dimensions :1210 Lx 600 D X 60 Mm H , M ) Return Air Grille With Collar Damper The Linear Diffusers / Grilles Shall Be Fabricated From Aluminum Extruded Sections. The Diffusion Blades Shall Be Extruded, Flush Mounted Type With Single Or Double Direction Air Flow. The Frame Shall Be Of Aluminum Extruded Section And Shall Hold The Louvers Tightly In Fixed Position. The Dampers As Described Under Grilles Shall Be Provided Wherever Specified. Return Air Grills With Damper At Room Side 800X400. , N ) Antistatic Pvc Flooring I ) The Cleanroom Flooring Shall Be Esd - Pvc 2Mm Thick And The Electro Static Dissipative Will Be Homogeneous Constructed Product Sliced From A Pressed Vinyl Block To Assure A Highly Flexible Tile Of Dense Construction, Dimensionally Stable, Extremely Hard Wearing, With A Completely Non-Directional Pattern. , Ii ) Esd Flooring Includes, Dedicated Earth Pit And Interconnecting Copper Strip 30X5 Mm Thick- 48 Rmt , O ) Cleanroom Lighting I ) Class 100 Cleanroom Lightscleanroom Teardrop Light Fittings For Iso 5 ( Class 100 ) And Surface Mounted Fittings To Be Provided Throughout The Facility To Achieve The 400-450 Lux Lighting Levels. The Teardrop & Surface Mounted Light Fittings Shall Comprise Of A Powder Coated Extruded Aluminum Body And Clear Acrylic Diffusers. Uv Filtration Film Having 350-400 Nm Thickness To Be Applied On Lights Or Uv Tube Sleeves Shall Be Used , Ii ) Class 1000 Cleanroom Lights: Supply And Installation Of Cleanroom Compatible Led Lights. The Envisaged Lighting Level In Clean Rooms Is 500 Lux, At 90 Cm Above The Floor. Lights Must Be Openable Towards Inside The Room. Dimensions: 600X600 Mm Power: 42 W , P ) Air Showersupply Of Ss304 Single Entry Class 10, 000 Airshower 1500 Lx 1500 D X 2300 H In Mm* Dimensions:1500 Lx 1500 D X 2300 H In Mm* Material Of Construction: Ss304 1.6 Mm Thick* Class 100 Compatible* Two Stage Filtration Eu6-Prefilter ( 95% Down To 5 Micron ) For Return Air & Fresh Air Intake* Doors: Ss304, 1, 6 Mm Thick Doors With Double Walled Flush Glass View Panels & Door Closer* Statically & Dynamically Balanced Motor- Blowers With Suspension Arrangement To Reduce Noise Level For Suction And Booster* Differential Pressure Gauge: 1 No. * On / Off Switches* Pao Test Port* Door Interlock Systems – To Ensure That Both The Doors Cannot Open At The Same Time & To Ensure That Both The Doors Will Be Locked During The Time Air Flow Is On.* Timer For Setting Air Shower Operation Time ( Settable For 30 Seconds To 5 Minutes ) * Emergency Stop Button* Straight Entry – Straight Exit / 90° L Type Door Opening * Automatic As Well As Manual Working. , Q ) Static Pass Box Dimensions 600X600x600 In Mmmoc: Ss304 , R ) Sterile Garment Storage Cabinet Supply And Installation Of Ss304, 1.6Mm Thicksterile Garment Storage Cabinet 1200X600x2100 In Mm , B ) Cleanroom Hvac A ) Air Handling Unit I ) Class -100-Ahu- Ahushall Be Of Double Skin, With 45+5 Mm Thick Puf Insulation Sand-Witched Panel, 0.8 Mm Thick Percolated Gss Outer Skin And 0.8 Mm Thick Plain Gi Sheet Inside. The Density Of Puf Insulation Shall Be Minimum 38 Kg / M3.The Casing Shall Incorporate Thermal Break Profile Aluminium And All Other Necessary Design Features To Ensure That Condensate Does Not Occur During All Seasons.Supply Air:4.853 M3 / S, Return Air:4.1 M3 / S , Fresh Air:0.735 M3 / Stotal Fan Static:150 Mm Wg, Cooling Coil Suitable For Chilled Water / Refrigerant Capacity:40 Tr, Heating Coil Capacity:76 Kw , Ii ) Class -1000-Ahu- Ahushall Be Of Double Skin, With 45+5 Mm Thick Puf Insulation Sand-Witched Panel, 0.8 Mm Thick Percolated Gss Outer Skin And 0.8 Mm Thick Plain Gi Sheet Inside. The Density Of Puf Insulation Shall Be Minimum 38 Kg / M3.The Casing Shall Incorporate Thermal Break Profile Aluminium And All Other Necessary Design Features To Ensure That Condensate Does Not Occur During All Seasons. Supply Air:4.382 M3 / S, Return Air:2.733 M3 / S , Fresh Air:1.649 M3 / Stotal Fan Static:150 Mm Wg, Cooling Coil Suitable For Chilled Water / Refrigerant Capacity:40 Tr, Heating Coil Capacity:57 Kw , B ) Chiller Unit ( 2W+1 S ) Supplying, Installing, Testing And Commissioning Of Ahri Certifiedair Cooled Scroll Water Chilling Units Of 40 Tr Capacity ( Actual ) Complete With Twin Screw Design Compressor With Star-Delta, Squirrel Cage Induction Motor, Starter Panel Machine Mounted, Water Cooled Condenser, Insulated Chiller, Flow Switch At Chiller And Condenser, Neoprene Pads, Integral Refrigerant Piping And Wiring, Bms Interface Unit Modbus, Counter Flanges Along With Flanged Connection For Condenser And Cooler Water In / Out Connections, Complete Charge Of Refrigerant And Oil, Accessories As Required And Called For, Automatic And Safety Controls Mounted In Central Micro-Processor Based Console Panel And All Mounted On A Steel Frame Complete As Per Specifications. Motor Shall Be Suitable For 415±10% 50 Cycles. 3Phase Ac Supply And Motor Cable Terminal Box Shall Be Suitable To Connect Copper Cabling. Refrigerant Used Shall Be Ozone Friendly Hfc134a / R410a As Detailed In Specifications. First Chiller Shall Be Factory Tested At Design Conditions At 100%, 75%, 50% And 25% Load. Cooling Capacity: 40 Trwater Flow-900 Lpmlpmsupply Water Temp. In Deg C- 5-7 Deg C Return Water Temp In Deg C-12 Deg C , C ) Chilled Water Pumps For Chillers ( 1 W+1S ) I ) Chilled Water Pumps Horizontal & Centrifugal Type Pumps. Supplying , Installation, Testing And Commissioning Of The Pumps Shall Be Horizontal, Close Coupled , Single Stage , Centrifugal , End Suction With Backpull Out Design. Hence , The Rotating Unit Can Be Removed And Serviced Without Disconnecting The Suction And Discharge Piping. The Pump Shall Be Balanced Statically And Dynamically. The Pump Are At Constant Speed And Suitable For Vfd Drive. The Noise Level Shall Not Exceed 75 Dba At 1M From The Source.The Pumps Shall Be Bms Compatible. Flow Rate:900 Lpm, Total Head: 30 M, Moc: Body : Ci, Impellor: Ss304 , Ii ) Chilled Water Piping With Al. Cladding Insulation: Chilled Water Piping With Al Claddingshall Be Installed For: Ahuand Pumps. Moc Of Pipe Shall Be Sch10 Ss304 With All Accessories , D ) Gi Ducting Supply, Installation, Testing & Commissioning Of Pre-Fabricated Gi Sheet Metal Ducting ( Prefabricating Ducting Means Duct Fabrication On Cnc Machines ) Complete With Gi / Ms Supports ( Complete Supporting Structure To Install Ducts At Site ) With Fully Threaded Gi Rods, Gi Nuts And Bolts ( With Check Nuts Wherever Applicable ) , Vanes, Splitters, Thermal Isolation Blocks, Etc. As Per Drawings And Smacna Standards For 4 Inch And 2 Inch Pressure Class. Ducting Will Have Ductmate Flanges With Food Grade Rubber Gasket Between Theflanges. All Duct Supports Shall Have Minimum 3 Mm Thk. Insulated Tape Between Support And Duct. All Ducting Seam To Be Sealed With Rtv Sealant. The Zinc Coatingthickness Should Not Be Less Than 120 Grams / Sq, Mtr ( Gsm ) .All Duct Joints Shall Be Inspected For Leakage. I ) 24G , Ii ) Ms Supporting System , E ) Insulation Supply, Installation Ofnitrile Rubber Insulation With One Side Aluminum Faced. The Insulation Material Shall Be Fm Approved. The Insulation Shall Have Fire Performance Such That It Passes Class ‘O’ As Per Bs 476 Part 6 For Fire Propagation And Class 1 As Per Bs 476 Part 7 For Surface Spread Of Flame. All Insulation Joints ( Including Flange Joints ) To Be Sealed With 3 Width Self Adhesive Tape. I ) 19Mm Thick Insulation , Ii ) 16Mm Thick Insulation , F ) Dampers Manual Low Leakage Volume Control Damperof Class 4 As Per Bs En 1751 ( Permissible Leakage Allowed -6.2 L / S / Sq M, Test Certificate Required ) And Shall Be Made Out Of 18G Gi, Opposed Type Multi Aerofoil Shape Blade With Handle And Wing Nut, Clearly Marked With Open / Close, Percentage Open, Locking In Position And Sealing Arrangement For Branches. The Dampers Should Be Suitable For Manual & Motorized Operation And Shall Have The Plain & Rigid Base Plate To Install Actuator. Damper Shaft Rod Shall Be Square. I ) Gi Round Damper 250Mm Dia 18 G , Ii ) Flexible Insulated Duct 200 Mm Dia , G ) Flexible Canvas Connection Supply Of 150 Mm Deep Antivibration Flexible Joints Made Out Of Imported Fire Resistance Flexible Double Canvas Sleeve With Extruded Aluminium Frame / Flanges On Both Sides , C ) Cleanroom And Hvac Electrical A ) Hvac Electrical Dbsupply, Installation, Testing And Commissioning Of Floor Mounted Type Vfd Electrical Control Panel And Provision Formicroprocessor Controller With Hmi ( Refer To The I / O Points Mentioned In The Technical Specifications Document Under Section 4.3: Plc Panel With Hmi ) Provision For :Safety Interlock I ) Ahu Blower-Vfd-6 Kw, 3 Ph , Ii ) Chiller Unit-41 Kw, 3 Ph-Contactor , Iii ) Heater- Ssr-60 & 80 Kw 3 Ph , Iv ) Pumps-8 Kw, 3 Ph- Contactor With Star Delta Starter , V ) Exhaust Blower-8 Kw 3 Ph, -Contactor With Star Delta Starter , Vi ) Process Cooling Chiller-8 Kw, 3Phcontactor , Vii ) Compressed Air Plant -8 Kw, 3 Ph Contactor , Viii ) Di Water Plant- 3 Kw , 3 Ph Contactor , Interlocks I ) Flow Switch , Ii ) Ahu Door Interlock , Iii ) Chiller-Pump Interlock , Iv ) Smoke And Fire , V ) Thermal Interlock , Vi ) Access Control Emergency Interlock , B ) Cleanroom Electrical Sub Db - Ups Db And Raw Power Db Supply, Installation, Testing And Commissioning Of Wall Mounted / Floor Mounted Type Distribution Board. Provision At Db: I ) Cleanroom Sub Db - 2 Nos ( 1 Ups, 1 Raw Power ) , Ii ) Cleanroom Lighting ( 40W ) - 1 Ph , Iii ) Cleanroom Power Points ( 5 / 15A ) , Iv ) Fan Filter Units ( 2.5 A ) - 1 Ph , V ) Air Shower ( 1.5Kw ) - 3 Ph , Vi ) Sterile Garment Cabinet ( 6 A ) - 1 Ph , Vii ) Static Pass Box ( 6A ) - 1 Ph , Viii ) Access Control System ( 6A ) -1Ph , Ix ) Cctv - 1Ph , X ) Clear Room Equipments: 3Ph 32 A , Xi ) Cleanroom Power Points:1Ph 5 / 15 A Power Points , C ) Electrical Cabling And Accessories Hvac Cabling: Hvac Cabling Shall Be Laid In Metal Trunking ( Electrical Incoming Power To Hvac Panel, Sub Db Will Be Provided By Iitm ) I ) Cabling For Ahu Blower-6Kw- 2Nos.-4 Mm2, 4 Core Armored Cable , Ii ) Cabling For Ahu Blower Interlock And Emergency Light- 2Nos.- 2.5Mm 2, 3 Core Cable , Iii ) Cabling For Modulating Valve- 2Nos.- 1.5Mm 2 Shielded 3 Core Cable , Iv ) Cabling For Heaters-3 Ph , 60 Kw & 80 Kw 2Nos.6Mm 2, 3 Corearmored Cable , V ) Cabling For Chiller- 41 Kw-3Nos.- 25Mm2, 5 Core Armored Cable , Vi ) Cabling For Pumps- 8 Kw-2 Nos.-4 Mm2, 4 Core Armored Cable , Vii ) Cabling For Process Cooling Chiller- 8 Kw-1 Nos.-4 Mm2, 4 Core Armored Cable , Viii ) Cabling For Compressed Air Plant- 8 Kw-1 Nos.-4 Mm2, 4 Core Armored Cable , Ix ) Cabling For Exhaust Blowers- 8 Kw-2 Nos.-4 Mm2, 4 Core Armored Cable , X ) Cabling For Di Water Plant- 3 Kw-1 Nos.-2.5 Mm2, 4 Core Armored Cable , Xi ) Cabling For - Flow Sensor- 2 Nos.1.5Mm2 Shielded 3 Core Cable , Xii ) Cabling For - Room Temp And Rh- 2 Nos.1.5Mm2 Shielded 3 Core Cable , Xiii ) Cabling For - Thermal Sensor-2 Nos.-1.5Mm2 Shielded 3 Core Cable , D ) Cabling For Cleanroom Equipments Cabling For Cleanroom Equipments Shall Be Layed Through Pvc Dado I ) Cabling For Cleanroom Lights-30 Nos- 2.5Mm 2, 3 Core Cable , Ii ) Cabling For Fan Filter Units-16 Nos.- 1.5Mm 2, 3 Core Cable , Iii ) Cabling For1ph Power Points-30 Nos.-2.5Mm 2, 3 Core Cable , Iv ) Cabling For 3Ph, 32 A, 5 Wire , Power Points - 10 Nos- 4Mm2, 5 Core Cable , V ) Cabling For Air Shower- 1 Nos-2.5Mm 2, 5 Core Cable , Vi ) Cabling For Garment Cubicle- 1 Nos, .- 2.5Mm 2 , 3 Core Cable , Vii ) Cabling For Access Control System-2 Nos.- 1.5Mm 2, 3 Core Cable , Viii ) Cabling For Cctv- 11 Nos-Cat 6 Cable , Ix ) Earthpits , D ) Process Utilities A ) Gas Lines For N2, Ar And O2supply And Installation Ofuhp Gas Lines Double Cylinderauto Changeover Over Panel For N2, Ar & O2 I ) Double Cylinder Auto Changeover Panel For N2- 1 Nos. , Ii ) Single Cylinder Auto Changeover Panel For Ar- 1 Nos. , Iii ) Single Cylinder Auto Changeover Panel For O2- 1 Nos. , Iv ) 1 / 4 Ss316 L Ep Pipes , V ) Tap Off Points With Diaphragm Valve, Regulator And Gauge , Vi ) Supporting System And Clamps , Vii ) Cylinder Mounting Accessories , B ) Compressed Air ( Cda ) System I ) Supply Of Compressor Supply Of Oil Free And Moisture Free Scroll Compressor 9 Cfm Capacity, 10 Bar Pressure Rating , With 150 L Storagetank , Ii ) Supply And Installation Of Compressed Air Line: A ) Moc: Ss316l3 / 4 -50 Rmt , B ) Tap Off Points: Tap Off Points With Isolation Valve And Regulator , C ) Supply & Installation Of Process Cooling Water System I ) System Must Have Working And Stand By Pumps Of 50-60 Lpm At 17-19 Deg C At 4-5 Bar Pressure, Storage Tank Of 400 L, All Ss304interconnecting Pipes And Valves & Control Panel, Moc: Moc Of The System Ss304 , Ii ) Supply & Installation Of Process Cooling Water Distribution A ) Moc Of Distribution Lines: 1 Upvc Sch 80 , B ) No. Of Tap Off Points ( Tap Off Points Should Have Ball Valve, Gauge, Flow Meter, Prv ) , D ) Utility Drain Line I ) Utility Drain Line Shall Be Pp Sch 80 Dn 50Mm , Ii ) Tap Off Points , E ) Polypropylene Wet Chemical Bench Polypropylene Wet Chemical Bench-1800 Wx 950 D X 2300 H Mmmoc: Polypropylene Fire Retardant Utilities:N2, Di Water , Ro Water Connection, Drain, Power Points5 / 15A- 4 Nos, Lights- 2 Nos, Storage Trolley- 2 Nos. , F ) Scrubber And Exhaust Ducting Wet Scrubber I ) Pp+Frp Packed Bed Type Wet Scrubber For 3500 Cfm Capacity , Ii ) Pp+Frp 3+2 Mm Thick Ducting 300Mm Dia. , Iii ) Ppfrp Blower 2500 Cfm Capacity @ 350 Mm Total Static , Iv ) Tap Off Points With Vcd Dia. 200 Mm , G ) Fume Hood For Solvents Moc: Polypropylene Fire Retardant Dimensions: 1200 W X950 D X2300 H In Mmutilities:N2, Di Water , Ro Water Connection, Drain, Power Points5 / 15A- 4 Nos, Uv-Lights- 2 Nos, Storage Trolley- 2 Nos. , H ) Blower And Exhaust Ducting Blower Moc: Ss304 I ) Blower Capacity: 1000 Cfm @ 75 Mm Total Static , Ii ) Duct Moc: Ss304 200Mm Dia With All Accessories-25Rmt , Iii ) Bibo Box For Activated Carbon Filter , I ) Di Water Plant A De-Ionized Water System Consisting Of A Generation And Storage System For Generating And Storing Type-I ( Resistivity = 18 M?-Cm ) And Type-Ii Water ( Resistivity = 1 M?-Cm ) Should Be Provided. In Addition To The Resistivity Metrics, Plant Shall Be Recirculatory Type And Pressure Depended Type. Di / Type I Water Flow Rate:1-2 Lpm@ 1.5-2 Bar Ro / Type Ii Water Flow Rate:2 Lpm @ 1.5-2 Bar , J ) Di Water Pipingdi Water Piping Moc: Pp Pp Dn 25Mm Pipe With All Accessories- 70 Rmttap Off Points- 3 Nos.Tap Off Must Have Isolation Valve- 3 Nos. , E ) Spin Coater Programmable Spin Coater • Bowl-Shaped Process Chamber Which Can Hold Size 6 ( ~150 Mm ) Diameter Wafers Or 5 ( ~125 Mm ) Square Substrates • Ac Brushless Motor Featuring Bi-Directional Rotation / Agitation, High Acceleration, And A Wide Speed Range • Digital Process Controller For Easy Programming • Speed : 1-12, 000 Rpm • Accuracy <+-0.5% Of Full Speed • Time: 1 Second To 99 Minutes 59.9 Seconds In 0.1 Second Increments • Programs: Twenty Multi-Step Programs Or Manual Mode • Real Time Display Of Rpm, Time And Program Stamps • Input And Control Through Soft Touch Keypad • Acceleration: Up To 13K Rpm / Sec With Standard Chuck ( Programmable In 1 Rpm Increments ) • Pc Interface Software To Be Included • Fluid-Control Lid Directs Materials Towards Rear Drain — No Drips Should Be Encountered When Opening Chamber • Chemically-Resistant Lid With Ø3 / 4; ( Ø19 Mm ) Center Opening • Npp Vacuum Chuck For Ø50 Mm Through Ø150 Mm Substrates • Npp Fragment Chuck Adapter — Fits Over Above Chuck For Holding 10 Mm Through ~50 Mm Pieces Ø1.5; ( Ø38 Mm ) Npp Drain Port And Nitrogen Purge • Polypropylene Drain Container To Store Exhausted Drain Reservoir • With Necessary Interlock, Latch And Lock For Safety Of The Door • With Oil-Less Vacuum Pump ( 220 Vac, 50 / 60 Hz ) And Inlet Port , F ) Life Safety And Security System A ) Cctv - Cameras , B ) Access Control System For 1 Door , C ) Door Interlock System For Air Lock Room , D ) Smoke And Fire Detection System , E ) Local Area Network , F ) Telephone , G ) Local Fire Extinguishers : Suitable For A, B, C Fire Classifications 5 Kg Capacity Suitable For Cleanroom Application , G ) Cleanroom Furniture I ) Ss316l Cleanroom Cross Over Bench 2100X400x550mm , Ii ) Ss316l Working Table 1500X900x750mm With 2 Power Points , Iii ) Ss316l Tables With Under Table, Table Dimensions 1200X750x750, Under Tablecubicles 500X700x700, 2 Drawers And 1 Door , Iv ) Class 100 Compatible Cleanroom Chairs , V ) Class 100 Compatible Cleanroom Stools , Vi ) Polypropylene Chemical Storage Cabinet 900 W X550 Dx2100 H In Mm , Vii ) Ss316l Cleanroom Bins-Dia 350X650 H In Mm , H ) Room Differential Pressure Gauges , I ) Temp And Rh Indicator , J ) Engineering, Design And Drawings , K ) Documentation , L ) Commissioning And Validation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
TenderDetail
Loading tenders