BRR : 11995164
Tender Brief : Tender for Purchase Of Mill Vfd Panel For 450Kw Motor , Mill Vfd Panel For 450 Kw Motor , Motor Duty Class Iv- Accordingly Vfd To Be Selected • Vfd Rating: 560 Kw (Suitable For Constant Torque) • Input Supply: 415V, 3Phase, 50 Hz • Vfd Rated Current: 1035A Minimum • Vfd Type: 6 Pulse • The Vfd Should Be Rated For Minimum 1035A At 50 Deg C Ambient Temp. And After Derating For 4 Khz Switching Frequency For Smooth Operation Of Motor At Entire Speed Range (Vfd Sizing/Derating Calculation To Be Provided To Match This Specification And Motor Overload Class) • Overload Class-Iv For Mill Application:... Read More
Tender Value
₹
8,00,000
Submission Date
01-09-2026
Participated Bidder List
2 No of Bidder(s)
| Sr No. | Bidder Name | Bid Analytics | Technical Bid | Financial Bid | AOC | Bid Value | Rank |
|---|---|---|---|---|---|---|---|
| 1 | cnet-technologies | Bid Analytics | |||||
| 2 | cnet-technologies | Bid Analytics |
Work Detail
tender for purchase of mill vfd panel for 450kw motor , mill vfd panel for 450 kw motor , motor duty class iv- accordingly vfd to be selected • vfd rating: 560 kw (suitable for constant torque) • input supply: 415v, 3phase, 50 hz • vfd rated current: 1035a minimum • vfd type: 6 pulse • the vfd should be rated for minimum 1035a at 50 deg c ambient temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed range (vfd sizing/derating calculation to be provided to match this specification and motor overload class) • overload class-iv for mill application: 150% overload for 1 hour 200% overload for 120 sec scope of supply • ip-42 floor mount panel, ral 7035, bottom cable entry, (make: rita/bch/eldon/vfd oem) • lcd graphical hmi on panel door • input acb-1250a mdo type, 3 phase • multi function meter • external input/dc choke- 3% impedance for harmonic suppression • vfd output filter- lc filter/choke- minimum 3% impedance • ac vfd module withrs 485 modbus communication, ai- 3 nos, ao- 3 nos & relay output - 3 nos. • vfd start/stop/reset push button on panel door • vfd speed inc-dec push button on panel door • ryb/run/trip indication • control wiring should be from tin platted copper cable to avoid corrosion. (control function shall be suitable for mill application) • local/remote/dcs selector switch (one ai/2 ao/ 3 do/2 di for dcs operation) • galvanic isolators for all 3 analog input & outputs • auxiliary contractor- (relays are not acceptable) • back curved high speed cooling fan with mcb • control supply transformer with mcb • temperature scanner -8 window for mill motor • common mode filter for reduces motor bearing noise and bearing current, thereby increasing motor bearing life. • dol starter for motor cooling with mpcb • panel space heater with thermostat • panel light with door switch lcs/remote station • ip55 enclosure • start/stop push buttom, vfd run/ trip indication) & fwd/rev switch • rpm meter- 0 to 1500 rpm make: amtech, abb, delta & cg note: your organization is responsible for the installation, commission and operation of the drive for the crushing season 2026-27 , motor duty class iv- accordingly vfd to be selected • vfd rating: 630 kw (suitable for constant torque) • input supply: 415v, 3phase, 50 hz • vfd rated current: 1190a minimum • vfd type: 6 pulse (control= dtc & safety= sto) • the vfd should be rated for minimum 1190a at 50 deg c ambient temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed range (vfd sizing/derating calculation to be provided to match this specification and motor overload class) • overload class-iv for mill application: 150% overload for 1 hour 200% overload for 120 sec scope of supply • ip-42 floor mount panel, ral 7035, bottom cable entry, (make: rita/bch/eldon/vfd oem) • lcd graphical hmi on panel door • input acb-1250a mdo type, 3 phase • multi function meter • external input/dc choke- 3% impedance for harmonic suppression • vfd output filter- lc filter/choke- minimum 3% impedance • ac vfd module withrs 485 modbus communication, ai- 3 nos, ao- 3 nos & relay output - 3 nos. • vfd start/stop/reset push button on panel door • vfd speed inc-dec push button on panel door • ryb/run/trip indication • control wiring should be from tin platted copper cable to avoid corrosion. (control function shall be suitable for mill application) • local/remote/dcs selector switch (one ai/2 ao/ 3 do/2 di for dcs operation) • galvanic isolators for all 3 analog input & outputs • auxiliary contractor- (relays are not acceptable) • back curved high speed cooling fan with mcb • control supply transformer with mcb • temperature scanner -8 window for mill motor • common mode filter for reduces motor bearing noise and bearing current, thereby increasing motor bearing life. • dol starter for motor cooling with mpcb • panel space heater with thermostat • panel light with door switch lcs/remote station • ip55 enclosure • start/stop push buttom, vfd run/ trip indication) & fwd/rev switch • rpm meter- 0 to 1500 rpm make: amtech, abb, delta & cg note: your organization is responsible for the installation, commission and operation of the drive for the crushing season 2026-27 , motor duty class iv-accordingly vfd to be selected • vfd rating: 630kw (suitable for constant torque) • input supply: 415v, 3 phase, 50 hz • vfd rated current: 1190a minimum • vfd type: 6 pulse • the vfd should be rated for minimum 1190a at 50 deg c ambient temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed rang ( vfd sizing/derating calculation to be provided to match this specification and motor overload class) • overload class-iv for mill application: • 150% overload for 1 hour • 200% overload for 120 sec (control= dtc & safety= sto) make: amtech, abb, delta & cg , motor duty class iv-accordingly vfd to be selected • vfd rating: 560kw (suitable for constant torque) • input supply: 415v, 3 phase, 50 hz • vfd rated current: 1035a minimum • vfd type: 6 pulse • the vfd should be rated for minimum 1035a at 50 deg c ambient temp. and after derating for 4 khz switching frequency for smooth operation of motor at entire speed rang ( vfd sizing/derating calculation to be provided to match this specification and motor overload class) • overload class-iv for mill application: • 150% overload for 1 hour • 200% overload for 120 sec (control= dtc & safety= sto) make: amtech, abb, delta & cg
View Original Notice/Document
Result Documents
Tender Documents
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender
Technical Evaluation In Progress
Technical bid evaluation is currently in progress. Awarded bidder details will be available after completion of technical scrutiny.
TechnicalBid
Similar Tenders Results