View Bid Results For Manufacturing Machinery Tenders

We found 348 Bid Results related to manufacturing machinery tenders. You can find Contractor details who won manufacturing machinery tenders along with contract details in Bid awards announcements section.

Filters
Stage
242
67
39
Tender Publishing Platform
29
319
State / UT
27
88
68
42
22
16
12
9
9
8
7
7
7
6
6
6
5
5
4
3
3
3
3
3
2
2
1
1
Contract Value
112
52
114
68
Publish Date
0
0
0
0
0
Sector
26
68
63
49
27
26
18
14
12
12
11
9
7
5
5
4
3
3
2
2
2
1
1
1
1
1
1
Ownership
7
231
53
27
22
10
3
2
Within keyword
Active filters:
Showing 1–7 of 348 tenders matching your filters
1.
Water Resources and Irrigation #11491318 AOC
Repairs To Electro- Mechanical Items And Civil Works In Gandhinagar L.I.Scheme On Tungapadu Vagu Near Gandhinagar (V), Damaracherla(M), Nalgonda District (5Th Call).-Excavation for Structures- Mechanical Means ( Data adopted from MORTH) Earth work in excavation in all kinds of soils of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material Depth upto 3 m Excavation in ordnary rock (including HDR) without blasting including boulders above 0.3 m upto 0.60 m dia. for foundations of canal cross drainage and other appurtenant structures and placing the excavated stuff neatly in specified dump area or disposing off the same as directed etc.,complete with initial lead upto 50m and initial lift upto 3m. Providing & constructing Sand filling below foudation including cost of all materials,machinery, labour, watering, ramming etc., complete with initial lead upto 50 m and all lifts. Providing and laying insitu vibrated M-10 ( 28 days cube compressive strength not less than 10 N / sq mm ) grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates for piers and abutments including cost of all materials, labour, machinery, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete with initial lead upto 50 m and all lifts.Note: If water is to be brought from other place add only lead charges @ 500 ltr / cum. (Cement content: 220 kg / cum with use of super plasticiser(0.4% by wt. of cement), CA : 0.90cum, Blending Ratio of CA--50:30:20, FA : 0.40 cum) Providing and laying insitu vibrated M-15 ( 28 days cube compressive strength not less than 15 N / sq mm ) grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates for sub-structure / super- structure works including cost of all materials,machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position,levelling, vibrating, finishing, curing etc., complete with initial lead upto 50 m and all lifts.(Cement content: 280 kg / cum with use of super plasticiser(0.4% by wt. of cement),CA : 0.80cum, Blending Ratio of CA--65:35, FA : 0.45 cum) Manufacture, supply and Delivery of R.C.C. Socket and Spigot pipes conforming to B.I.S. 458/2003 at ex-factory (rate per meter of effective length ) including conveyance and Laying and Jointing etc. (500 mm Dia) Manufacture, supply and Delivery of R.C.C. Socket and Spigot pipes conforming to B.I.S. 458/2003 at ex-factory (rate per meter of effective length ) including conveyance and Laying and Jointing etc. (400 mm Dia) Supply and fixing of Mild Steel works including all materials and labour charges like cutting, welding , bending etc for finished item of wok Supply and fixing of Structural Steel including all materials and labour charges like cutting, welding , bending etc for finished item of wok Surface cleaning of metal surfaces by chemical cleaners and then by hand and power tool cleaners and removing dust. After cleaning,applying primary coat with one coat of Zinc rich epoxy primer to a thickness of 40 microns ,followed by finishing coats 2 coats with Solventless Coal tar epoxy with material, labour and all accessories with all leads and lifts CRS Masonry in CM (1:3) 1st Sort Hot dipped Galvanized Iron Chain link mesh 8 gauge - (4.0 mm) as per IS:2721-1979: 2 x 2 (50 mm x 50 mm) - 8 Gauge Supply and erection of 0-500V Digital Volt meter on exisiting panel boardincluding connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMENS. Supply and erection of 0-100 / 200 / 400 / 600 /1000 Digital Ammeter of size 96x96mm on existing panel board including connections etc., complete.MAKES : CONZERVE / ELMEASURE / L&T / SEIMEN Supply and fixing of Three phase Electronic energy meter, 240 V AC, 50 Hz as per IS 13010 upto 40 A range with 200% overload capacity complete with connections etc., complete on the existing board.MAKES : CONZERVE / ELMEASURE/ MECO/HPL/ HAVELLS Supply and erection of LED indication lamps on the existing panel board,including connections etc., complete.Makes : L&T / C&S / SALZAR / HPL MAKE. Supply and erecting porcelain Pin type insulator suitable for 11KV line with suitable hardware on existing cross arms. Filteration of transformer oil as per ISS specifications filters to di electric strength above 40 KV at site. Transformer oil tested as per IS-335 - 1972 (per Ltr) Supply of heavy duty long barrel aluminium lugs confirming to I.S specifications suitable for 400 Sq.mm cable etc complete with nuts,bolts and washers.Makes: DMI / Jainson / Dowels or equivalent make as approved by the department Supply of heavy duty long barrel Aluminium lugs confirming to I.S specifications suitable for 240 Sq.mm cable etc complete with nuts, bolts and washers.Makes: DMI / Jainson / Dowels Supply and erecting approved make 11KV, 5KA metal oxide lightning arrestors suitable for 11 KV supply with necessary materials on existing cross arm. Supply of 400A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL / Havells / Siemens / Indo Asian. Supply and fixing of 250A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL /Havells / Siemens / Indo Asian Supply & Fixing of D.O.L Starter 250V, Single phase, 50Hz. With SS enclouser comprising of contactor with bi-metallic relay with necessary push buttons, etc.complete suitable for 5 HP Motor Makes: Siemens / Crompton / L&T / BCH. Supply of 32A HRC Fuse Links. Makes : L & T / C & S / Standard / HPL / Havells / Siemens / Indo Asian. Carryout routine maintenance, servicing and testing of 630A to 1000A L.T. ACB by cleaning fixed contacts ,moving contacts and arc chutes including servicing and putting the ACB in perfect working condition after getting all relay and ON ,OFF mechanism etc done with only manufacturing companies Supply and erection of approved make 11 kV Outdoor type gang operated Air break switch of 400 A capacity with 3 post pin type insulator per phase, mounted in Horizontal/Vertical position with necessary channels on cross arms with necessary channels on cross arms with adequate length of C class GI pipe for operating handle provided with Lock & Key at suitable height from ground level with necessary clamps. Routine maintenance of transformer in operation covering insulation resistance oil, break down strength. Reconditioning / replacement of silicazel, cleaning of transformer and topping upto oil level if required (extra cost will be paid for oil). Carryout routine maintenance and servicing of LT.Cubical panel board having approximately 15 to 22 Nos of switches cleaning with power brower and servicing the contacts, tightening the connection of incoming and outgoing cables, and clicking the operating.machanism for smooth functioning of switches and putting them in smooth working condition. Supply and fixing of 15.0 KVAR rating capacitor duty Contactor Supply and fixing of 25.0 KVAR rating capacitor duty Contactor Supply and Run of 50 mm x 6mm G.I. strip including cost of all accessories and labour charges etc., complete Supply and erection of Panel mounting cubical type 32A TPN 415V, 50 Hz. switch disconnector fuse unit complete with front drive mechanism with door inter lock,padlocking arrangement etc., complete with fuse links on existing control panel.Makes : L&T / SCHNEIDER / C&S / ABB / SIEMENS Supply,fixing and transportation of 43 / 45 W +/-10% (>=4500 Lumens) LED Street light Body made of high grade pressure die – cast Aluminium alloy with corrosion resistant powder coat, having protective toughened glass cover, Less Glare, IP 66 (Silicon gasket ensures Optical & Electrical compartments are IP 66) protected, wide operating voltage range, P.F > 0.90, System having efficacy >100 lumens/watt, with Ingress protection IP66, Potted driver, Driver surge protection >10KV, THD<15%, CCT: 3000- 6500K as desired by the department and as per IS, CRI>70, Inbuilt Electrical protections like Over voltage, short circuit, Over load, Open Circuit, Miswiring, etc complete with BIS certification with 5 years warranty. The contractor must furnish the manufacturer warranty letter, LM 79 and LM 80 certificates. LUMINAIRE MAKE : PHILIPS / OSRAM / GE Venture / CROMPTON / BAJAJ / Wipro / Jaquar / Eveready / Halonix / Keselec / HAVELLS / POLYCAB / SURYA / SYSKA / Capart / Fortune Arrt / FIEM / Panasonic / Arraystorm / GM / Goldmedal LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG / LG LEDs. Supply of 240 Sqmm 3.5 Core XLPE insulated, 1100V grade armored aluminum cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable / Beljin / Ollivin Supply of 400 Sqmm 3.5 Core XLPE insulated, 1100V grade armored aluminum cable with ISI mark as per specification confirming to IS:7098 (Part - I) Makes : Torrent / Unicab / Universal / Polycab / Havells / Gloster / KEI / Finolex / Paragon / RR kable / Beljin / Ollivin Supply and erection of LT current transformer with bar primary 100/5A to 1000 / 5A ratio in the existing panel including connections etc., complete. MAKE : KAPPA Providing independent earthing for Important equipment with 100mm dia Heavy gauge C.I ( Cast iron ) pipe with Flange 2.5m long enclosed in C.C/ brick masonry chamber of 450m x 450m x 400mm with R.C.C. Slab cover duly providing staggered holes filling with salt and charcoal from the bottom of the pipe giving earth connection from electrode through flange with all accessories and labour charges complete, as per IS specifications 732/1982 (Part II) Supply of 11 KV/22 KV Hand gloves S & F Bronze Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 40 mm NB Size. S & F Bronze Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size. S & F GI Union 40 mm nominal size 1st Quality S & F GI Union 25 mm nominal size 1st Quality Supply of Grease Supply of Packing Rope to the work site. Supply of Grease gun of 1 kg capacity. Complete dismantling of DV 40x40 vacuum pump, over hauling with replacement of pump bearings-2 Nos. Pump shaft gun metal bushes , pump glands, reconditiong of port plates, impeller lock nuts , studs, wheel bearing grease assembling of pump erection on base plate, correct alignment of pump and motor, successful trial run at site including cost of materials , labour charges, transportation charges of pump from scheme to workshop and vice versa and all other incidental charges etc. complete Supply and fixing of PH316 UNIQUE make coupler made of rubber Supply and fixing of Packing Studs to the work site including labour charges, etc., as directed by Engineer- in- Charge. Supply and fixing of Star and Delta Contactor in panel board, L&T MNX 265 Complete dismantling of (300mm-500mm dia) NRV. overhauling, replacement of wornout parts like spindle nut facing of shutter providing new bolts and nuts, rubber packing , assembling of valve including cost of materials , labour charges, transportation charges from scheme to workshop and vice versa and all other incidental charges etc. complete Complete dismantling of (300mm-500mm dia) Sluice Valves. overhauling, replacement of wornout parts like spindle nut facing of shutter providing new bolts and nuts, rubber packing , assembling of valve including cost of materials , labour charges, transportation charges of pump from scheme to workshop and vice versa and all other incedental charges etc. complete Complete repairs to 100mm dia Aircushion Valve and fixing including all other incidental charges etc. complete Complete repairs to 600mm dia Zero velocity valves and all other incidental charges etc. complete Complete repairs to 200mm dia Air Valves and all other incidental charges etc. complete Repair of 600mm Dia Expansion joint in Pressure main Complete Dismantling,Overhauling of WPIL make HCF pump run by 210 HP by replacing with new sleeves, bearings,impeller rings, chucknuts etc and aligning the pump true to the alignment of motor and successful trial run at site including transportation charges from site to work shop and vice versa Rewinding of Electric motor of 210 HP, 3Phase up to 1485 RPM squirrel cage induction motor with copper wire, for required IR values including minor repairs, hot air blowing lubrication of ball bearings, bush bearings and erection on base plate, correct allignment of pump and motor, testing of motor for original speed etc. trail run at site,including cost of materials, labour charges transportation charges of motor from scheme to workshop, workshop to scheme and all other incidental charges etc. aas directed by Engineer in charge. Supply and fixing of new Terminal Plate for 210 HP Motor ABB make Supply and fixing of 6316 C3 - 6319 C3 bearings set to the motor Supply and fixing of Thermal Overload Relay- CT ratio set (Make: L&T) MN12 9-15 Amps Supply of Timer ET 100 (L&T) Complete Servicing of 11 KV, 630 A, 25kA Outdor type Load Break switch replacing of damaged outgoing/incoming insulators, servicing the spring charge mechanism, Tighten the bus bar connections, Replacement of Indicator lamps and putting the Load Break Switch in perfect working condition after getting all relay and ON,OFF mechanism etc done with only manufaturing companies Painting to Transformer Yard pole structure after duly cleaning existing metal surfaces Supply and fixing Panel board lock Internal wiring inside Pump House 6 mm rubber flange for packing
Contract Date: Ref. Documents Contract Value : 23.60 Lakh
Government Departments No of Bidders 1
2.
Drinking Water Supply and Sanitation #11348134 Technical Bid
Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
4.
Educational and Research Institute #11299551 Price Bid
Tender For Supply Of Library Books , Library Books (Refer Nit) , Industrial Safety And Human Behaviour Kaila 9788174734532 , Engineering Mechanics Vela Murali Bks456005 , Earthquake Resist Design Structural Shashikant Dugg Bks643652 , Surveying And Levelling Subramanian 9780198085423 , Practical Railway Engineering, 2Nd Ed Clifford Bonnett 9780000990136 , Geographic Information Systems Gis For Disaster Management 2Ed Brain 9781032552460 , Design Of Structural Elements Chanakya 9781138046436 , Wind Loading Of Structures 3Rd Edition John D. Holmes 9780367241803 , Structural Analysis 3/Ed Menon 9788184877342 , Concrete Pipes And Pipelines Joshi Bks426990 , Strength Of Materials Basavarajaiah 9788173714580 , Geotechnical Engineering Debashis Moitra 9788173719905 , Textbook Of Environmental Studies For Undergraduate Courses 3 Ed Bharucha 9789389211788 , Intelligent Transportation Systems Srinivasa Kumar 9788195400928 , Transportation Engineering Srinivasa Kumar 9789389211160 , Structural Analysis With Finite Elements Hartmann 9788132208945 , Strength Of Materials Vol 1 Binu Sukumar 9789388005029 , Geospatial Technology Dwivedi 9789380381480 , Heavy Metal And Metalloid Contamination Of Surface And Underground Water Gupta A. 9781032728582 , Fundamentals Of Environmental Engineering Danny D Reible 9781566700474 , Computer-Aided Highway Engineering S Goswami 9781032728483 , Fundamentals Of Hydrology Davie 9781032251936 , Highwall Mining : Applicability, Design & Safety Porathur J. L. 9781032728919 , Environmemtal Pollution Control Engineering 4Ed Rao 9788122472288 , Plane Surveying 3Ed Chandra 9788122438802 , Design Of Reinforced Cement Concrete Vol 1 Structural Elements Bhavikatti 9788122440515 , Strength Of Materials, 2/Ed Jindal 9789352861521 , Fundamentals Of Hydraulic Engineering Sy Houghtalen 9789332507593 , Geotechnical Engineering Coduto,Yeung 9789332587427 , Strenth Of Materials Jindal 9788131759097 , Dynamics Of Structures 2Nd Ed Jain 9789357059350 , Finite Element Method With Cd Eldho Desai Shah 9788131724644 , Soil Mechanics And Foundation Engineering Purushotama Rai 9788131790816 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Dynamics Of Structures In Si Unites 5Ed Chopra 9789353945251 , Elementary Engineering Hydrology Deodhar 9788131708057 , Environmental Studies Basak 9788131721186 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Strength Of Materials Rao 9781108454285 , Plumbing Engineering Nikhil Anthony 9788119365128 , Fundamental Of Ground Improvement Engi Prof.Dr.R.K. Khit 9788195916948 , Surveying And Levelling : Part - 1 Kanetkar Kulkarni Bks644037 , Surveying And Levelling : Part - 2 Kanetkar Bks644038 , A Textbook Of Strength Of Materials Rajput 9789355010704 , Building Construction Bhavikatti 9789325960794 , Fundamental Of Reinforced Concrete Chandra Bks498526 , Irrigation Engineering And Hydraulic Structures Sharma Bks535826 , Surveying I Anne Mary 9788183717304 , Highway Engineering Subramanian 9788183716888 , Strength Of Materials Bansal Bks534222 , Reinforced Cement Concrete Design (Reinforeced Concrete Structures) Punima 9788131809426 , Building Construction Rangwala Bks502124 , Civil Engineering Drawing Rangwala Bks440591 , Soil Mechanics & Foundation Engineering Modi 9788189401306 , Engineering Materials Rangwala Bks385325 , Bridge Engineering Rangwala Bks554100 , Harbour Dock And Tunnel Engineering Srinivasan Bks502125 , Solid Hazardous Watse Management 2Ed Rao 9789389354621 , Textbook Of Remote Sensing And G.I.S 4Ed Reddy 9789381075975 , Reinforced Concrete Design P.B Sharma 9789391910419 , Energy Environment Ecology And Society Anil Kumar 9788178002576 , Solved Problems In Geotecnical Engineering Sharma 9789395038478 , Highway Engineering Suganthi Bks411034 , Highway And Railway Engineering Santhanam Bks638485 , Construction Materials & Tech Mathankumar Bks638450 , Prefabricated Structures Soundrarajan Bks638488 , Structural Analysis-I Santhanam Bks479564 , Green Building Design Molykutty Bks503088 , Irrigation Engineering Basak 9780074635384 , Estimating Construction Costs Peurifoy 9780071239455 , Design Of Steel Structure Duggal 9780070260689 , Concrete Technology Gambhir 9781259062551 , Engineering Mechanics Timoshenko 9781259062667 , Flow In Open Channels Subramanya 9789353166298 , Reinforced Concrete Design 4Ed Pillai 9789354601026 , Surveying Vol - Ii 5Th Edn Duggal 9789353167523 , Surveying And Levelling Basak 9789332901537 , Prestressed Concrete 6Ed Krishna Raju 9789387886209 , Fluid Mechanics White 9789355322043 , Strength Of Materials Rattan 9789385965517 , Surveying Vol - 1 Duggal 9789353167509 , Environmental Studies-3Ed Joseph 9789352605170 , Construction Planning, Equipment Peurifoy 9780070706996 , Fluid Mechanics Fundamentals And Applic Cengel 9789353166212 , Schaums Outline Of Finite Element Analysis Buchanan 9789389691375 , Wind Energy Theory And Practice 3Ed Ahmed Bks662294 , Bituminous Road Construction In India Kandhal 9789391818821 , Mechanics Of Composite Structures Vasiliev 9781138582101 , Satellite Towns In Neometropolitan Development In India Amit Chatterjee 9789811932052 , Sustainable By Design Walker 9781032973685 , Management Of Quality In Construction Ashford 9781138607163 , Disaster Managament 2/Ed Pandey 9789357461610 , Remote Sensing And Image Interpretation Thomas Lillesand 9789354642104 , Composite Structures Of Steel And Concrete 3Ed Johnson 9788126539819 , Strength Of Materials 2Nd/Ed Debabrata Nag 9788126534876 , Reasoning Ability And Quantitative Aptitude Tcy Online 9788126559008 , Green It Strategies And Applications Using Envir Intell Bhuvan Unhelkar 9781032054025 , Bioenergy For Sustainability And Security Behera 9789381891438 , Textbook Of Engineering Geology Annadurai 9789385259937 , Structural Dynamics Mukhopadhyay 9788180520907 , Matrix And Finite Element Analysis Mukhopadhyay 9788180520754 , Irrigation Engineering & Hydraulic Structures Suresh 9789383656899 , Strength Of Materials 2Ed Vendateshan 9789383656646 , Concrete Technology Job Thomas 9788131526682 , Steel Design Segui 9788131526651 , A First Course In The Finite Element Methods Logan 9789353507855 , Civil Engineering Materials Sivakugan Tuladhar 9789386650382 , Soil And Water Conservation Engineer Fangmeier 9788131524985 , Principles Of Foundation Engineering 9Th Ed Das 9789355738110 , Elements Of Civil Engineering Balasubramanya 9789387511576 , Soil Mechanics & Foundation Engineering Huat Prasad 9788131529591 , Principles Of Foundation Engineering Das 9789386650955 , Analysis Of Structures On Elastic Tsudik 9788131518953 , Strength Of Materials : Mechanics Gupta 9789355737717 , Steel Design With Mt Segui 9789386650887 , Prestressed Concrete Structures, 6Ed Dayaratnam 9788120417915 , Fundamentals Of Reinforced Cement Concrete Designs Gahlot 9789385915611 , Instrumental Methods Of Analysis Willard 9788123909431 , Tb Of Soil Mechanics And Foundation Engineering:Geo Technical Engg Murthy 9788123913629 , Civil Engineering Through Objective Type Questions 3Ed Gupta 9788123907970 , Advanced Reinforced Concrete Design 3Ed Raju 9788123929606 , Design Of Reinforced Concrete Structures 4Ed Dayaratnam 9788120414198 , Structural Dynamics Paz 9788123909783 , Modern Prestressed Concrete Libby Bks465269 , Textbok Of Solid Wastes Managemnt Khan 9788123909448 , Analysis & Design Of Substructures, 2Ed Swami Saran 9788120417007 , Building Repair And Maintance Management Gahlot 9788123912431 , Advanced Foundation Engineering Murthy 9788123915067 , Modern Construction Management 7Ed Harris 9788126572298 , Groundwater Hydrology Rushton 9788126539772 , Textbook Of Highway And Traffic Engineering Saxena 9788123924175 , Airport Engineering Saxena 9788123915500 , Construction Dewatering And Groundwater Control 3Ed Powers 9788126541669 , Quality Management Of Cement Concrete Construction (Pb) Gahlot 9788123916989 , Tb Of Water Supply And Sanitary Engineering Husain 9788120416833 , Design Of Bridges 5Ed Raju 9788120417984 , Essentials Of Bridge Engineering 6Ed Victor 9788120417175 , Building Construction Handbook Chudley 9789381269169 , Design And Construction Of Concrete Shell Roofs Ramasamy 9788123909905 , Strength Of Materials, Vol-Ii:Advanced Theory And Problems Timoshenko 9788123910772 , Construction And Project Managment 2Ed (Pb 2018) Krishnamurthy 9789386217790 , Water And Wastewater Calculations Manual 2Ed Lin 9789353162863 , Design Of Stell Structures Abu-Saba 9788123905389 , Prestressed Concrete Problems And Solutions Raju 9788123925424 , Water Resources And Irrigation Engineering Ganesaguru Bks588955 , Dam Engineering Asthana 9789381891469 , Sedimentary Rocks In The Field A Colour Guide Stow 9781874545699 , Soil Mechanics Basic Concepts & Engineering Aysen 9780415383936 , A Tb Of Fluid Mechanics And Hydraulic Machines Bansal Bks493063 , Intelligent And Sustainable Cement Production Chatterjee A.K. 9781032728445 , Total Quality Management 5Ed Besterfield 9789353066314 , Matrix Methods Of Structural Analysis Kothandaraman 9789357059190 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Limit State Design Of Steel Structures Duggal 9789353164874 , Schaums Outline Of Reinforced Concrete Everard 9789389538656 , Earthquake Resistant Design Of Structures Agarwal Bks344533 , Building Materials Varghese 9788120350915 , Total Quality Management 2Ed Mukerjee 9788119364299 , Principles Of Geotechnical Engineering 10 Th Ed Das 9789355738103 , Building Materials Products Properties And Systems Gambhir 9780071077606 , Gate 2025 Civil Engineering - Guide By Gkp C L Educate 9789356817593 , Gate 2025 Mechanical Engineering Guide Gkp 9789356817746 , Engineering Design Dieter 9789355322258 , Economics And Principles Of Management Vinoth Kumar 9788194244646 , Vector Mechanics For Engineers Dynamics Beer 9789353166656 , Aviation Maintenance Management Kinnison 9780071076838 , Theory Of Machines S S Rattan 9789353166281 , Turbomachinery Dubey 9789353161156 , Engineering Mechanics 4/E Kumar 9780070681811 , Modern Compressible Flow: With Historica Anderson 9789355320070 , Programming In Matlab Patel Mittal 9789332524811 , Finite Element Analysis Moaveni 9788131760642 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Additive Manufacturing And 3D Printing Technology Awari Thorat 9781041049562 , Practical Guide To Vehicle Refinishin Woodstock 9781032963570 , The Internet Of Mechanical Things The Iot Framework Sami Salama Hussen 9781041038573 , Energy Storage Systems And Components Alfred Rufer 9781041049470 , Metal Cutting Theory & Practice Stephenson 9780824758882 , Classical Mechanics Problems And Solutions Carolina C Llie 9781032983608 , Product Design Baxter 9781032967882 , Thermal Measurements & Inverse Tech Orlande 9781439845554 , The Induction Machines Design Handbook Boldea Bks331229 , Modeling And Control Of Engineering Systems Clarence W. De Silva 9781420076868 , Fundametals Of Production Planning And Control Chapman 9788131717394 , Applied Thermodynamics For Engineering Technologist 5Ed Eastop 9788177582383 , Classical Mechaincs Goldstein 9788131758915 , Introduction To Robotics Saha 9789355326461 , Thermodynamics-Basc And Applied Ganesan 9789353161279 , Ethics In Engineering 5/Ed Martin 9789355325075 , Digital Marketing Chaarlas 9788119243983 , Non Conventional Energy Resources Khan 9789352601882 , Supply Chain Logistics Management Bowersox 9789353162580 , Mechanical Metallurgy Appuraj Thiyagrajan Deiter 9781307834840 , Schaums Outline Of Continuum Mechanics Mase 9789389691283 , Schaums Outline Of Statics And Mechanics Of Materials Nash 9789389691399 , Maleev & Hartmans Machine Design 6Ed Grover 9788123926322 , Mass Transfer Theory And Applications Narayanan Bks440952 , Manual Of Fire Safety Prakash 9788123919904 , Gpropulsion Systems For Space Applications Satyanarayana 9789395038553 , Mechanics Of Materials Si Version 5Ed Philpot 9789354643293 , Introduction To Robotics 3/Ed Niku 9789357461306 , Advanced Mechanics Of Materials 6Ed Boresi 9788194726395 , Design And Analysis Of Experiments Douglas & Montgomery 9788126540501 , Machine Component Design Robert C.Juvinall 9788126559732 , Callisters Materials Science And Engineering, 2Nd Ed Balasubramaniam 9788126541607 , Process Dynamics And Control 4Ed Dale Seborg 9789354248429 , Engineering Optimization Theory And Practice 5Ed Rao 9789357461238 , Principles Of Modern Manufacturing Si Version Groover 9788126573059 , Convective Heat And Mass Transfer South Asian Edi Mostafa Ghiassiaan 9781107511811 , Continuum Mechanics Jog C S 9781108437141 , Singers Engineering Mechanics Statics & Dynamics ( Si Units ) 3Ed Vijay Kumar 9788178002194 , Analytical Mechanics Fowles 9788131501115 , Thermal Sciences Potter Scott 9788131529461 , Physical Metallurgy Principles Abbaschian 9788131520697 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Computational Fluid Dynamics & Heat Ghosh Dastidar 9788131533079 , Internet Mrketing With Mt Zahay 9789355734570 , Mechanical Vibrations Theory And Applications Kelly 9788131526033 , Mechanics Of Materials, Enhanced Edi Goodno--Gere 9789355737847 , Fundamentals Of Mechatronics Jouane 9788131526026 , Mechanics Of Materials Strength Of Materials Pilli/Bala 9789386668509 , Workshop Manufacturing Practices Ai Juneja 9789387994614 , The Finite Elements Methods - Its Basis & Fundamentals 7/Ed Zienkiewiez 9789351071587 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , The Robotic Process Automation Handbook : A Guide To Implementing Ri Systems Taulli 9781484275306 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Industry 4.0 : The Industrial Internet Things Gilchrist 9781484249703 , The Finite Element Method A Practical Course 2Ed Liu 9789351071594 , Elasticity-Theory, Applications & Numerics 2Ed Sadd 9789351072270 , Energy Resources And Their Utilisation R.K. Khitoliya 9789394917040 , Workshop Theory And Practice Delilah Sam 9788119365098 , New Persp. In Hybrid Vehicle Technology Samual Rodrigues 9788119365418 , Natural Gas Engineering Selvin 9788119365197 , Machine Shop Theory Samual Rodrigues 9788119205639 , Applied Mechanics Laboratory Samual Lobo 9788119365760 , Robotics: Emerging Opportunities Adrian Dsilva 9788119523702 , Advances In Hypersonic Vehicles Samual Rodrigues 9788119365500 , Machine Elements Samual Rodrigues 9788119205691 , Work And Energy Parth Chavda 9788119365234 , Design Thinking : A Comprehensive Textbook Tiwari 9789357468640 , Welding Technology Sanfras Monteiro 9788119523023 , Combustion Engineering Samual Rodrigues 9788119205943 , Fluid Machinery Noel Vincent 9788119365029 , Renewable Energy Roy 9789384007157 , Engineering Graphics Using Autocad 7/Ed {Pb} Elanchezhian C 789387938564 , Introduction To Micromachining 2Ed Jain 9788184873610 , A Systems Approach To Automotive Technology Erjavac 9788131512111 , Emotionally Intelligent Design Pavliscak 9789352138029 , Mechanics Of Solids Binu Sivakumar 9789380381671 , Mechanics Of Solids Christian Johnson 9789385983085 , Jet Engines Jaganathan 9789380381497 , Essentials Of Management, 11Ed Koontz 9789353168148 , Disaster Management Subramanian Bks481407 , Engineering Fluid Mechanics Kumar Bks613447 , A Textbook Of Fluid Mechanics Rajput Bks648302 , A Textbook Of Thermal Engineering ( Lpspe ) Khurmi Bks613483 , Materials Science And Engineering Raghavan 9788120350922 , Engineering Economics 2Nd Ed Panneerselvam Bks661039 , A Tb Of Theory Of Machine Gupta R Khurmi Bks408347 , Energy Security And Sustainability Shukla A. 9781032728926 , Mechanical Engineering Jain Bks554131 , Engineering Materials And Metallurgy Annamalai 9789386235046 , Kinematics Of Machinery Baskar Bks462932 , Thermal Engineering Swaminathan Bks638475 , Engineering Materials And Metallurgy Baskar Bks638439 , Lean Manufacuring Kalyana Chakravarthy Bks638464 , Elements Of Mechanical Engineering Singh Bks448529 , Fundamentals Of Manifacturing Engineering Singh 9789380156002 , Strength Of Machine Elements Ghorpade 9789384726003 , Observability Engineering Achieving Production Excellence Majors 9789355422996 , Research Methodology 5Ed Kothari 9789389802559 , The Automotive Body Vol 2 Morello 9788132208884 , Kinematics Of Machines Kumar 9789388005425 , Essentials Of Heat And Fluid Flow In Porous Media Narasimhan 9789382127215 , Analysis Of Composite Structures Decolon 9789380931463 , Theory Of Elasticity Chandramouli 9789380381633 , Principles Of Composite Material Mechanics 3Ed Gibson Bks380369 , Introduction To Combustion Engineering Basic And Applied Amitava Sarkar 9789357053129 , Textbook Of Finite Element Analysis Seshu Bks414440 , Engineering Thermodynamics Savithiri Bks442773 , Automobile Engineering Vol-Ii Kirpal Singh 9788180142512 , An Introduction To Mechanical Engine 4Ed Wickert Lewis 9789353507473 , Welding Engineering & Technology Parmar Bks53191 , Manufacturing Technology Vol 1-Foundry Forming Rao 9789353160500 , Manufacturing Technology Singh 9789381162385 , Dynamics Of Machines Balaguru 9789386668608 , Unconventional Machining Vivekanandhan Bks613041 , Basic Civil And Mechanical Engineering Shanmugam 9789355329547 , Engineerin Drawing 2Ed Shah / Rana 9788131710562 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Fuel Cell Technology Handbook Hoogers Bks333321 , Robots And Robotics Miller 9789387572966 , Non Destructive Testing And Materials Vivekanandhan Bks476859 , Engineering Mechanics Nelson 9780070146143 , Engineering Tribology 4Ed Stachowiak 9789351071679 , Materials Selection In Mechanical Design 5Ed Ashby 9789351073864 , Automobile Engineering Ayyappan Karthikeyan Bks464418 , Thermal Engineering Swaminathan Bks638475 , Automobile Engineering Babu Singh Bks587323 , A Textbook Of Production Technology Sharma Bks479783 , A Textbook Of Mechatronics Rajput Bks554009 , Automobile Engineering Jain 9780070445291 , Engineering Mechanics Statics & Dynamics Khanchani 9788180521089 , Basic Mechanical Engineering Prabhu 9788183715737 , Powder Metallurgy Ramakrisnan 9789381714485 , Additive Manufacturing Technology Hari Prasad 9789353500481 , Switching And Finite Automata Theory Jha 9780521176804 , Introduction To Mechanics 2Nd Ed Mahendra K Verma 9788173719813 , Basic And Applied Thermodynamics - A Ready Recknor Bhat 9789388005074 , Basic Refrigeration And Airconditioning 4Ed Ananthanarayanan 9781259062704 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Mechatronics Sathish Kumar Bks476759 , Automobile Engineereing Vol I Singh Bks247106 , Process Planning And Cost Estimating Selvakumar Bks480422 , Non Conventional Energy Resources Sawhney 9788120346093 , Non Conventional Energy Resources Sobh Nath Singh 9789332543577 , Introduction To Micromachining 2Ed Jain 9788184873610 , Vector Mechanics For Engineers Statics/Dynamics (Sie) Beer 9789353166625 , Fluid Mechanics &Hydraulics Rev &Updated Edn Ukarande 9789381162538 , Mechanical Measurements - Revision 6Ed Beckwith 9789353945633 , Vibration Monitoring Testing And Instrumentation C W.De Silva 9781032292137 , A Treatise On Turbomachines Gopalakrishnan Bks321517 , Construction Materials Vs Karthikeyan Bks476834 , Design Of Machine Elements Bhandari 9789390177479 , Mechanical Vibrations Bhava 9788131732489 , Design Of Transmission Systems Baskar Bks476758 , Engineering Materials And Metallurgy Baskar Bks638439 , Manufacturing Technology Vivekanandhan Bks638476 , Design Of Machine Elements Arunraja Bks638441 , Mechanical Vibrations Nag 9788126530908 , Power Plant Engineering Dhanasekar Bks505300 , Statistical Quality Control A Modern Introduction 6Ed Montgomery 9788126525065 , Additive Manufacturing Technologies Shiva Ahuj Shukla 9789357462419 , Hydraulics And Pneumatics Dixon Bks638479 , Engineering Principles Of Ground Modification Hausman 9789351341871 , Engineering Thermodynamics 6Ed Nag 9789352606429 , Refrigeration And Air Conditioning Arora 9789390385843 , Enterprise Resource Planning 4Th Edn Leon 9789353167820 , Foundations Of Material Science And Engg 6Th Edn Smith 9789355322173 , Shigleys Mechanical Engineering Design Budynas 9789390219636 , General Studies Paper - I ( 2025 ) Mhe 9789355327796 , Erp Demystified 3/Ed Leon 9789383286676 , Heat And Mass Transfer 6Ed Cengel 9789390185283 , Engineering Noise Control: Theory And Practices 4Ed Bies 9780415487078 , Rapid Prototyping And Engineering Applications Frank W.Liou 9781138569577 , Strength Of Materials Vol Ii Binu Sukumar 9789388005418 , Mechatronics A Foundation Course Clarence W.De Silva 9781138569553 , Design And Analysis Of Randomized Algorithms Hromkovic 9788132231592 , Metrology And Measurements Annamalai 9789388005463 , Fluid Mechanics And Machinery Molykutty 9789391549725 , Micro Electro Mechanical System Design Allen 9780824758240 , Micromachining Of Engineering Materials J Mcgeough 9781032419794 , Gas Turbine Combustion-3 Rd Ed Lefebvre 9781138569584 , Ergonomics Laboratory Exercises Joseph Gallwey 9781032973005 , Introduction To Biofuels Mousdale 9781439812075 , Environmental Engineering Charles Monteiro 9788119205509 , Power Plant Engineering Lijo Thomas 9788119365036 , Industrial Engineering Richard Carvalho 9788119205523 , Design & Operation Of Heat Exchanger Gerhard Rott 9788119365425 , Hydro Power Gerhard Rott 9788119205912 , Air Conditioning And Ventilation Systems Lijo Thomas 9788119365401 , Materials Science And Engineering Raghavan 9788120350922 , Automation And Collaborative Robotics (Dp) Mathews 9781484277102 , Design Management : Create, Develop And Lead Effective Design Teams Picchi 9781484283615 , Heat And Mass Transfer 2Ed Karwa 9789811926099 , Testing Of Metallic Materials 2Ed Suryanarayana 9788178001340 , Introduction To Engineering Materials 2/Ed Murray George 9781032530772 , Mechanics Of Composite Materials 2/Ed Jones R.M 9781138571075 , Reliability Evaluation Of Enginnering Systems 2Ed Billinton 9788181285522 , Workshop Practice Manual 6/Ed Reddy 9788178003078 , Finite Element Analysis 2D Lakshmi Narasai 9789389354225 , Engineering Mechanics Pb Lakshmi 9789390211609 , Engineering Mechanics 2Ed Harbola 9788131518298 , Environmental Science And Engineering Rajesh Gopinath 9789387511569 , Materials Science And Engineering Periodical Renewal Gilmore 9788131520451 , Environmental Science With Mt 16 Th Ed Miller 9789355738899 , Fluid Mechanics Munson Huebsch 9788126553433 , Engineering Mechanics: Dynamics, Si Version Meriam Bolton 9788126565375 , Engineering Mechanics Statics And Dynamcs James Meriam Kraige 9789354248566 , Engineering Fluid Mechanics Elger 9788126564491 , Engineering Mechanics Applied Mecha Gupta 9789353505240 , Machine Design Data Book Ramana 9789387593879 , Heat Transfer Alan 9789332575066 , Theory Of Machines 3Ed Bevan 9788131729656 , Introduction To Enviromental Engineering And Science Masters 9789332549760 , Heat And Mass Transfer Mayilsamy 9788131733837 , Engineering Thermodynamics 4Ed Rogers 9788131702062 , Operations Research :An Introduction-10Th Ed Hamdy Taha 9789352865277 , Engineering Mechanics - Statics & Dynamics Shames Rao 9788177581232 , Automation, Production Systems, And Computer - Integrated Manufacturing 5Th Ed Groover 9789361592959 , Introduction To Materials Science For Engineers 9E/D Shackelford 9789357059978 , Fundamentals Of Engineering Drawing Luzadder 9789332549982 , Engineering Materials Properties And Selection 9Ed Budinski Naraimhulu 9789332574045 , Thermodynamics Rajadurai Bks471287 , Environmental Science And Engineering Kaushik 9788122436471 , Engineering Optimization 4Ed Rao 9789395161800 , Cad/Cam/Cim 5Ed Radhakrishnan 9789395161855 , Finite Element Analysis With Ansys Workbench Tickoo 9789355513007 , Industrial Waste Management Mathankumar Bks480053 , Metrology And Measurements Vivekanandan Bks638442 , Finite Elements Analysis Baskar Bks534307 , Environmental And Agriculture Kavitha Bks638465 , Energy Materials Bandarenka A.S 9781032530789 , Digital Twin Ranjan Ganguli 9781032934198 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Quantum Computation Helmut Bez 9781032983738 , Wind Electrical Systems Bhadra, 9780195670936 , Metal Fatigue In Engineering Stephens 9788126539215 , Introduction To Industrial Internet Of Things And Industry 40 Sudip Misra 9781032146751 , Sustainable Manufacturing For Industry 4.0 Jayakrishna K. 9781032728728 , Reverse Supply Chains: Issues And Analysis Gupta S.M. 9781032729039 , Industry 5.0 The Future Of The Industrial Economy Uthayan 9781032600130 , Gas Turbine Heat Transfer Cooling Je-Chin Han, Sandip Dutta 9781439855683 , First Course In Aerial Robots And Drones (A) Bestaoui Sebbane 9781032963518 , Handbook Of Induction Heating Rudnev 9780824708481 , Fracture Mechanics (Forth Ed) T.L Anderson 9781032292120 , Fire Safety Engg Design Of Structures, 2Ed Purkiss 9788131220085 , Future Energy Improved Sustainable And Clean Opitons Letcjer 9788131220849 , Introduction To Finite Elements In Engineering 5/E Tirupathi 9781009461818 , Fundamentals Of Gas Dynamics Babu 9781910390009 , Fundamentals Of Propulsion Babu 9788180522529 , Engineering Metrology 3Rd Ed Narayana Bks396066 , Engineering Mechanics Kumaravelan Bks315205 , General Aptitude For Competitive Examinations Pattanaik Bks670722 , Dictionary Of Heat Power Engineering Ramalingam 9789386923035 , Environmental Pollution Principles Narayana Bks353570 , Production Processes Luqman 9788123918983 , Tractors And Their Power Units, Hb Lijiedahal 9788123905013 , Metal Cutting Principles Shaw 9788123901367 , Sheet Metal Press Tools Design And Making A Practical Approach Luqman 9788123925134 , Solid State Physics Wahab 9788184877786 , Practical Non - Destructive Testing, 3Ed Baldev Raj 9788173197970 , Mechanics Of Machines, 3Ed Ramamurti 9788173198922 , Handbook On Quality And Productivity Improvement Of Concrete Nayak 9788184876390 , Environmental Studies 4Ed Rajagopalan 9789354978944 , Finite Element Methods Dhanraj 9780198073901 , Fluid Dynamics Raisinghania Bks320511 , Entrepreneurship 11/Ed Hisrich 9789390113309 , Thermodynamics 9Th Ed Cengel 9789353165741 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Vibration, 4/E Inman 9789332518483 , Thermodynamics 9Th Ed Cengel 9789353165741 , Schaums Outline Of Mechanical Vibration Graham Kelly 9789389538861 , Enterprise Resource Planning Singla 9789360531485 , Machine Drawing 51Ed Bhatt 9789385039560 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Total Quality Management 2Ed Mukerjee 9788119364299 , Heat Treatment : Principles And Techniques 3Ed Rajan 9788119364077 , Operations Research Panneerselvam 9789354437892 , Design Thinking Teun Den Dekker 9781032786018 , Aeroplane Ramalingam 9788193103159 , Faqs In Control Systems Engineering Pattanaik 9789394639003 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Total Quality Management 5Ed Besterfield 9789353066314 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Engineering Drawing Agrawal 9789353167448 , Cad / Cam : Computer - Aided Design & Manufacturing Groover 9788177584165 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Power Plant Engineering Hegde 9789332534100 , Hydraulics And Fluid Mechanics Hydraulic Machine Modi , Seth Bks291963 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Alternative Fuels For Ic Engines Krishnasamy 9789364441995 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Manufacturing Technology Vol 2-Metal Cutting Rao 9789353160524 , Fundamentals Of Heat And Mass Transer Kothandaraman Bks481435 , Mechatronics Electronic Control Systems In Mechanical And Electrical Eng Bolton 9789357052849 , Production &Operations Management 3Ed Panneerselvam Bks477079 , Engineering Drawing Agrawal 9789353167448 , Mass Transfer - Theory & Practice Begum/Anantharaman 9788120341692 , Industrial Robotics Control Frigeni 9781484294154 , Gate 2025 Production And Industrial Eng Gkp 9789356818170 , Engineering Vibration, 4/E Inman 9789332518483 , Fundamentals Of Engg Heat And Mass Transfer-5Ed Sachdeva 9789386070968 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Modern Machining Processes Pandey 9789386761835 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Materials Science For Mechanical Engineering Palanisamy 9789386923059 , Textbook Of Fluid Dynamics Chorlton 9788123908816 , Engineering Mechanics : Statics & Dynamics Kottiswaran Bks307984 , Robotics Rajmohan Bks480419 , Hmt Data Book Kothandaraman 9788812243594 , Design Data (Data Book) Psg Bks58578 , Digital Signal Processing 2Ed Paulo Diniz 9781108406703 , 8086 Microprocessor And Applications 3Ed Kani 9789354661327 , Wireless Telecommunication System & Network Mullett 9788131520123 , Operational Amplifiers & Linear Integrated Circuits Lal Kishore 9788177585667 , Mobile Computing Principles Bfar 9780521696234 , Microprocessors & Programmed Logic 2Ed Short 9788131709160 , Design With Pic Microcontroller Peatman 9788177585513 , Digital Systems Design With Access Code Nagoor Kani 9789354667688 , Introduction To Biomems Folch 9781032568225 , Introduction To Biomedical Equipment Technology 4Ed Carr 9788177588835 , Antennas & Wave Propagation Raju 9788131701843 , Raspberry Pi For Dummies Cook 9789357460422 , Digital Signal Processors : Architectures --Op Kuo 9788131717936 , Principles Of Electromagnetics, 6Ed Sadiku 9780199461851 , Advanced Digital Design With The Verilog Michael.D.Ciletti 9789332584464 , Neural Networks Kumar 9781259006166 , Embedded System 2Nd Ed Peckol 9789357463966 , Microprocessor And Peripherals Chowdhury Bks405737 , Networks & Systems Roy Choudhury 9789389802535 , Microcontroller Theory And Application With The Pic Rafiquzzaman 9788126548354 , Digital Signal Processing For Anna University Kani 9789354661006 , Digital Signal Processing 3Ed Kani 9789354661167 , Analog And Pulse Circuits Lakshmaiah D 9789389354201 , Electronic Devices And Circuits Orient 9789386235305 , Quantum Chemistry 7 Ed Levine 9789332558533 , Engineering Circuit Analysis 9/Ed Hayt 9789390185139 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Chip Design For Submicron Vlsi : Cmos Layout And Simulation Uyemura 9788131501955 , Microelectronics Neamen 9789354601637 , Neural Networks And Learning Machines Haykin 9789332570313 , Electronic Circuits : Fundamentals And Applications 5Ed Tooley 9781032726687 , A Course In Digital Signal Processing Pucca Bundh Porat 9788126534913 , Signals And System Apte 9781316615393 , Digital Design 6Ed Mano 9789353062019 , Principles Of Signal Processing And Liner System Lathi 9780198062288 , Fiber Optic Communications 5Ed Palais 9788131717912 , Circuits And Networks Sudhakar 9789339219604 , Introduction To Communication Systems Madhow 9781316608241 , Analog Communication Rao 9780070704800 , Arduino Based Embedded Systems Singh 9781032964058 , Next Generation Wireless Lans 2Nd Ed Perahia 9781107414617 , Arm Microprocessor System Tahir 9781138387539 , Digital Communication Mutagi Bks478677 , Advanced Microprocessors & Peripherals Bhurchandi 9781259006135 , Vlsi Design Chitra 9788183716598 , Television And Video Engineering Salai Thillai 9788183712194 , The Design Of Cmos Radio Frequency Integrated Circuits Lee 9780521613897 , Network Security : Private Communication In A Public World Charlie Kaufman 9788196874339 , Sensors And Transducers Patranabis 9788120321984 , Neuro Fuzzy And Soft Computing Jang Sun Mizutani 9789332549883 , Network Analysis Channa Venkatesh 9788131533215 , Circuits Carlson 9788131505861 , Op Amps And Linear Integrated Circuits : Concepts And Applications Fiore 9788131512340 , Mobile Computing Principles Bfar 9780521696234 , Instrumental Methods Of Analysis Willard 9788123909431 , Vlsi Circuits And Embedded Systems Hasan Babu 9781032906003 , Computer Organization And Embedded System-6 Th Ed Hamacher 9789339218317 , Network Analysis And Synthesis, 2Ed Singh 9789353166724 , Handbook Of Biomedical Instrumentations Khandpur 9789355328021 , Security And Privacy In Internet Of Things Lots Hu Fei 9781032707150 , Television & Video Engineering Veeralakshmi 9789380156699 , Power Quality Sankaran 9781138569249 , Introduction To Microcontroller Programming For Power Electronic Control Applications Rossi 9781032972183 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Signal Processing And Its Applications Senthil Kumar 9788195268726 , Multimedia Enabled Sensors In Iot Fadi 9781032599205 , Novel Wearable Antennas For Communication And Medical System Albert Sabban 9781041049579 , Internet Of Things Using Single Board Computers : Principles Of Iot And Python Programming Kanagachidam Baresan 9781484299258 , Handbook Of Optical Communication Networks Ilyas 9781498798037 , Communications System Laboratory Preetham Kumar 9781138603288 , Digital Watermarking And Steganography 2Nd Edition Shih 9781032972121 , Propagation Handbook For Wireless Communication System Design Crane 9780849308208 , The Internet Of Things In The Cloud Honbo Zhou 9781498770354 , Arduino Based Embedded Systems Singh 9781032964058 , 5G Mobile Communications Concepts And Technologies Saad Asif 9781032663159 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Semiconductor Physics And Devices, 3Ed Sze 9789354243226 , Digital Fundamentals 11Ed Floyd 9789332584600 , Electronic Devices And Circuits--11 Ed Boylestad Nashelsky 9789332542600 , The 8051 Microcontrollers & Embedded Systems 2Ed Mazidi 9788131710265 , A System C Primer 2Ed Bhasker 9788178001418 , Household Electricity And Appliances P.B Bhagava 9789390211265 , Image Processing Analysis And Mach Sonka 9789386858146 , Verilog Hdl 2Ed +Cd Palnitkar 9788177589184 , Modern Semiconductor Devices For Integration Hu 9788131730249 , Analog Integrated Circuit Design Isv 2Nd Ed Chan Carusone 9788126543939 , Textbook Of Digital Electronics Vasudevan 9789381714539 , Microwave Engineering 4Ed Das 9789390113347 , Analysis Of Microcontrollers For The Students Kothari 9789381714294 , Digital Signal Processing : For C.S.I.T Palani 9789380618388 , Fundamentals Of Digital Images Processing Jain 9789332551916 , Signals And Systems Sreenivasa Reddy 9789389354041 , Satellite Communications Pratt 9789354243035 , Analog Signals And Systems Kudeki 9788131787984 , Embedded Systems Handbook 2Ed System Design And Verification Zurawski Bks331222 , Vlsi Design And Eda Tools 2Nd Ed Sarkar 9788183714976 , Vlsi Design Das 9780198094869 , 8085 Microprocessor Pramod Borole 9789382127581 , Fundamentals Of Communication Systems Proakis 9788131705735 , Short Range Wireless Communication 3Ed Bensky 9789351073994 , Introduction To Fiber Optics Ghatak Ajoy 9781316644010 , The Definitive Guide To Arm Cortex M3 And Cortex M4 Processors Yiu 9789351071754 , Rf Circuit Design Ludwig 9788131762189 , Electric Circuits For Be/Betch 2Ed Kani 9789354663925 , Control Systems Nagoor Kani 9789389239010 , Digital Logic Circuits Nagoor Kani 9789354669989 , Microwave And Rf Design Steer 9789380381305 , Electrical Measurement And Measuring Instruments Rajput Bks543993 , Digital Signal Processing 3Ed Kani 9789354661167 , A Handson Course In Sensors Using The Arduino And Raspberry Pi Ziemann Volker 9781032791470 , Signal And Systems Simplified 2Ed Nagoor Kani 9789354661013 , Basic Electrical And Electronics Engineering 2/Ed Bhattacharya 9789332586505 , Ad Hoc Wireless Networks : Architectures & Protocols Murthy 9788131706886 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Digital Circuits Design Kothari 9789332543539 , Solid State Electronic Devices Streetman 9789332555082 , Wireless Communication Goldsmith 9780521704168 , Probability And Stochastic Processes 3Ed Yates 9789354243455 , Signals, Systems And Inference Oppenheim 9789356064676 , Electromagnetic Field And Waves Salivahanan 9788119896677 , Analog Design For Cmos Vlsi Systems Maloberti 9788181284341 , Vlsi Design Michael 9780849318764 , Cognitive Sensors And Iot Fadi 9781032599236 , Digital Design & Computer Organization Farhat 9780849311918 , Digital Intergrated Circuits Evegni 9780849330575 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Basic Electrical And Electronics Engineering Murugan 9789384726072 , Adaptive Antenna Arrays Chandran 9788181289322 , Networks Lines & Fields 2Ed Ryder 9789332559516 , Data Compression : The Complete Reference Salomon 9788184898002 , Electric Circuits Bell Bks321194 , Digital Signal Processing Oppenheim 9789332550339 , Iot Standards With Blockchain : Enterprise Methodology For Internet Of Things Upadrista 9781484284278 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Digital Signal Processing Oppenheim 9789332550339 , Digital Modulation & Coding Wilson 9788131721438 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , Introduction To Iot With Machine Learning And Image Processing Using Raspberry Pi Ambaji Kulkarni 9781032966885 , Biomedical Instrumentations And Measurements Cromwell 9789332556911 , Artificial Neural Networks For Engineers And Scientists Chakraverty S. 9781032729121 , Digital Communication Bhattacharya 9780070591172 , Signals And Systems 2/Ed Oppenheim 9789332550230 , Fundamentals Of Modern Vlsi Devices Yuan Taur 9781316649794 , Digital Systems:Principles&Design(Anna) Rajkamal 9789332535916 , Principles Of Cognitive Radio Vincent 9781107439900 , Digital Signal Processing 4Ed Proakis 9788131710005 , Op Amps And Linear Integrated Circuits Gayakwad 9789353949037 , Microwave And Radar Engineering Rao 9788131799444 , Introduction To Pspice Using Orcad For Circuits And Electronics Rashid 9789332555174 , Basic Electronics Saha 9781316632932 , Linear Integrated Circuits Salivahanan 9789353163808 , Principles Of Electronic Communication Orient 9789386235107 , Optoelectronic Devices And Optical Fiber Communication Chakrabarti 9789354667947 , Introduction To Vlsi Design Flow Sneh Saurabh 9781009200813 , Antennas And Wave Propagation Kraus 9789352606184 , Network Analysis Revised 3Ed Van Valkenburg/ Rathode 9789353433123 , Communication Systems : Analog And Digital, 3Rd Singh 9781259004605 , Internet Of Things The : How Smart Tvs Sm Miller 9789332552456 , Microwave Devices & Circuits 3Ed Liao 9788177583533 , Fundamentals Of Mobile Computing 2Ed Pattnaik Bks534717 , 5G Mobile And Wireless Communication Technology Pauline Cullen 9781009590921 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Circuits Analysis Theory And Practic Robbins 9788131519028 , Medical Instrumentation 5Ed : Application And Design : An Indian Adaptation Webster 9789354249150 , Microwave Engineering, An Indian Adaptation Theory And Techniques Pozar 9789388991087 , Wireless Communications 2Ed Molisch 9789354248795 , Controll System Eng. 8/Ed Norman 9789357463980 , Signals, Systems, And Transforms, 4/E Phillips 9789332518490 , Antenna Theory And Applications 4Ed Balanis 9789354248474 , Gate 2025 Electronics And Communication Eng.Guide Gkp 9789356819306 , Introduction To Analog And Digital Communication 2Ed Haykin 9789354644337 , Digital Image Processing Gonzalez 9789353062989 , Power Electronics (An Indian Adaption) Ned Mohan 9789354640278 , Dorfs Introduction To Electric Circuits Wiley India Edition Richard 9788126573493 , Electronic Devices 10Ed Robert Floyd 9789354493935 , Communication Systems 5Ed Haykin 9789354640896 , Modern Control Engineering Ogata 9789332550162 , Electric Circuits With Mt Kang 9789386650344 , The Intel Microprocessors : 8086/8088,80186/80188,80286,80386,80486,Pentium, Pentium Pro Processor, Pentium Ii - 8Ed Brey 9788131726228 , Modern Digital Electronics-5Th Edtion Jain 9789355321770 , Analog And Digital Electronics Roth 9789353502355 , Introduction To Communication Systems Madhow 9781316608241 , Voip Handbook Application Technologies Ahson 9781420070200 , Embedded Systems Handbook 2Ed Network Embedded System Zurawski Bks331227 , Matlab: An Introduction With Applications 6Ed Amos Gilat 9789357462174 , Fiber Optic Communication Systems 5Ed Agrawal 9789357461245 , Crc Handbook Of Modern Telecommunications 2Ed Morreale Bks331221 , Mathematical Aspects Of Signal Processing Sircar 9781107175174 , Rf And Microwave Semiconductior Device Handbook Golio 9780849315626 , Electronic Systems Maintenance Handbook, Second Edi Whitaker Bks322864 , The 8051 Microcontroller Ayala 9788131502006 , Digital Systems Design Using Vhdl W/ Roth 9788131518304 , Fundamentals Of Engineering Electromagnetics Cheng 9789332535138 , Basic Electronics-2Ed Kothari 9789352606467 , Power Electronics Essentials & Applications Umanand 9788126519453 , An In Depth Guide To Mobile Device Forensics Chuck Easttom 9781032785905 , Automotive Embedded Systems Handbook Navet Bks335190 , Wavelet Analysis With Applications To Image Process Prasad 9780849331695 , Primer On Wavelets And Their Scintific Applications Walker 9781032963617 , Face Detectin And Recognition: Theory And Practice Datta A.K. 9781032728964 , Fiber Optics & Optoelectronics Khare 9780195669305 , Mobile Cellular Telecomm 2E Lee 9780070635999 , Cmos Vlsi Design : A Circuits And Systems Perspective, 3Ed Weste 9788131762653 , Antennas Blake 9789380381268 , Mobile Communications, 2Ed Schiller 9788131724262 , Introduction To Wireless Systems Black 9788131726389 , Ad Hoc And Wilreless Sensor Network Athawale 9789356066137 , Linear Integrated Circuits Sathishkumar Bks476847 , Linear Integrated Circuits Dhanasekar Bks638493 , Embedded And Real Time Systems Ramprabu Bks476848 , Transmission Lines And Rf Systems Shanmugaraja Sivakumar Bks490771 , Transmission And Distribution Gayathri Bks476751 , Wireless Communication Santhosh Krishna Bks638491 , Digital System Design Edwindhas Bks638462 , Power Quality & Distributed Generation Jayaprakash 9788184876987 , Digital Signal Processing Antoniou 9780070636330 , Power System Engineering 3 Ed Kothari 9789353165116 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Principles Of Electronic Materials Kasap 9789390113866 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Principles Of Electronic Materials Kasap 9789390113866 , Wireless Communications : Principles Rappaport 9789356066212 , Communication Networks Fundamentals Leon 9780070595019 , Interoperability In Iot For Smart Systems Roy M. 9781032728100 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Learning Basics And Electronic Science Through Mcqs Priya 9789394639249 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Programmable Logic Controllers 6Th Ed Petruzella 9789355325860 , Modern Wireless Communication Haykin 9788131704431 , Signals And Systems 5Ed Ramesh Babu Bks505218 , Digital Signal Processing Ramesh Babu Bks503977 , Digital Image Processing 2Ed Sridhar Bks643706 , Digital Logic Circuits With Vhdl And Verilog Programs Nagoor Kani 9789354669606 , Wireless Communications : Principles Rappaport 9789356066212 , Digital Integrated Circuit 2/Ed Rabeay 9789332573925 , Brain Computer Interface Eeg Signal Processing Panigrahi 9781032851181 , Internet Of Nanothings And Wireless Body Area Networks Fadi 9781032599144 , Phyiscs For Electronics & Information Science Palanisamy 9789386923134 , Vlsi Design Sathyah Bks665018 , Basic Elec & Linear Circuits Bhargava 9781259006463 , Communication Networks Fundamentals Leon 9780070595019 , Linear Integrated Circuits Salivahanan 9789353160487 , Wireless Communications : Principles Rappaport 9789356066212 , Linear Integrated Circuits Salivahanan 9789353160487 , Digital Logic & Computer Design Mano 9789332542525 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Fundamentals Of Logic Design Roth 9789360535650 , Engineering Circuit Analysis 10E/D Hayt 9789364441094 , Digital Electronics Bignell 9788131520710 , Design Of Analog Cmos Integrated Circuit-2Ed Razavi 9789387067844 , Applied Machine Learning Gopal 9789354601590 , Essentials Of Digital Signal Process Using Matlab Ingle/Proakis 9788131517727 , Arm System On Chip Architecture Furber 9789332555570 , Smart Grid In Iot Enabled Spaces Fadi Ai Turjman 9781032598543 , Power Plant Engineering Nag 9789354600050 , Mathematical Analysis A Straightforward Binmore 9781107526235 , Algebra 2Nd Edition Michael Artin 9789353432751 , Discrete Mathematics Dhami 9780199452798 , Statistics And Numerical Methods 10Ed Vijayakumari 9789356062733 , Algebra, 3Ed Sahai 9788173198250 , Algebraic Topology M J Greenberg , J R Harper 9780367475604 , Algebra, 4Ed Sahai 9788184876208 , Concept Of Modern Algebra Pandey 9788184877069 , Friendly Introduction To Number Theory Silverman 9789353433079 , Elementary Differential Equations 8Ed Richard 9789332571617 , Introduction To Graph Theory West 9789332549654 , Linear Algebra Ubaidullah 9789391549893 , Higher Algebra Barnard 9789385923326 , Sequences And Series Arumugam 9789388005128 , Modern Analysis Arumugam 9789388005111 , Intorduction Topology And Modern Analysis Simmons 9789387465916 , Higher Algebra Hall Knight 9788174731043 , Analytical Geometry Veerarajan 9789388005142 , Transforms And Partial Diffrential Equations 3Rd Ed Muthucumaraswamy 9789391549473 , Multilevel Analysis: Techniques And Applications 3/E Hox 9781032938035 , Thomas Calculus 15Ed Hass 9788119896608 , Calculus Vil I 2Ed ( An Indian Adaptation) Apostol 9789354642630 , Calculus 10Ed Saturmino Salas Einar Hille Ga 9789390421961 , Introduction To Linear Regresion Analysis, 6Ed Montgomery 9789357461283 , Matrices Advanced Calculus & Complex Stewart 9789360534509 , Operations Research Mote 9788126556380 , Topology 2Ed James Munkres 9789353432775 , Linear Algebra 5Ed Friedberg 9789390168132 , Multivariate Calculus Joshi Bks498996 , Mathematical Analysis 6Ed Malik Bks413195 , Stochastic Processes 5Ed Medhi 9789389802245 , Human Resource Management Aswathappa 9789355323675 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Probability And Statistics For Engineering Devore 9789353506247 , Operations Research Panneerselvam 9789354437892 , The Elements Of Complex Analysis 3Ed Choudhary 9789388818780 , Optics 8Ed Ghatak 9789355328595 , Outline Of Beginning Physics Schaum 9789389538984 , Outline Of Astronomy Schaum 9789389538939 , Introductory Nuclear Physics 3/Ed Krane 9789354640834 , Physics Vol 2 5Ed David Halliday Resnick 9789354640438 , Physics For Scientists And Engineers Serway 9789355739223 , Non Conventional Energy Source Math 9789388005081 , Nuclear Physics Theory And Experiments 3Ed Roy 9788122449884 , Gravitation : Foundations And Frontiers (South Asian Edition) Padmanabhan 9780521178761 , Electricity And Magnetism Murugeshan 9789352837342 , Introductory Nuclear Physics Wong 9788126546060 , Modern Physics Murugeshan Bks367126 , Introduction To Electrodynamics South Asia Ed - 4/Ed David J. Griffiths 9781108822909 , Theoretical Astrophysics Vol 2 Padmanabhan 9781107400603 , Heat Thermodynamics And Statistical Physics Lal Subramanian Bks460942 , Classical Dynamic Of Particles Thornton 9788131518472 , Materials For Engineers And Technicians 7Ed Bolton 9781032973722 , Statistical Mechanics 2Ed (An Indian Adaption) Kerson Huang 9789354247736 , Atomic And Molecular Spectroscopy Rita Kakkar 9781108413206 , Laser Fundamentals Silfvast 9780521138475 , Engineering Chemistry 2E : Fundamentals And Applications Shikha Agarwal 9781108724449 , Organic Name Reations Sanjay Bari 9789389354737 , Basics Of Environmental Science Khosla 9788184874013 , Environmental Chemistry Singhu 9788122427318 , Biomaterials Principles And Applications Joon Park 9781032934167 , Organic Reaction Mechanisms Ahluwalia Bks366263 , Organic Synthesis Concepts And Methods 3Ed Pb 2014 Jurgen Hinri 9788126547227 , Engineering Chemistry Palanna 9789352605774 , Engineering Chemistry 2Nd Ed Wiley 9788126543205 , A Textbook Of Engineering Chemistry Dara Bks561640 , Engineering Chemistry Vairam & Kalyani 9788126543342 , Chemical Applications Of Group Theory Albert Cotton 9788194726364 , Environmental Science And Engineering Yuganath 9788183717014 , Environmental Science Isv 8Th/Ed Botkin, Killer 9788126534142 , Chemical Reaction Engineering 3Ed (An Indian Adaptation) Octave Levenspiel 9789354244605 , Outline Of Thermodynamics Schaum 9789389538540 , Textbook Of Chemical Engineering Thermodynamics Narayanan 9788120347472 , Communication Skills, 3Ed Sanjay Kumar 9789354978555 , English For Science & Technology-I Chellammal 9781009224796 , English For Science & Technology-Ii Francis 9781009251181 , Effective Technical Communication Rizvi 9789352605781 , Research Methodology Vinod 9789352863518 , Placement Interviews Skills For Success Anandamurugan 9780070700956 , Prowess Orient 9789354421242 , Research Methodology Panneerselvam 9788120349469 , Academic Writing A Handbook For Students Stephen Bailey 9781138615533 , Design Thinking In Technical Communication Jason C K Tham 9781041004356 , Principles Of Scientific And Technical Mohapatra 9789355327482 , Critical Thinking Idea Innovation And Creativity Richard H Mccuen 9781041000846 , Literature For Language Skills 2Ed Mahanand 9789388005470 , Academic Writing P.B Ajay Semalty 9789390211739 , Teaching English Through Folktales Mahanand 9789391549077 , An Introduction To Literary Studies Mario Klarer 9781032785974 , Heritage Of Tamils Muthuramalingam 9789391549718 , A Short History Of English Literature Saintsbury 9788174733054 , The English Language Wrenn 9788174733368 , An Introduction To The Study Of English Litetrature Hudson 9788174731197 , Rabindranath Tagores Ideational Challenges Bidyut Chakrabarty 9789356400122 , English Literature Long Bks476291 , Test Of Reasoning 7Th Edn Thorpe 9789389811513 , Science And Technology 8Ed Agarahri Ravi 9789355326324 , Excel Reasoning Arun Sharma 9789355329455 , Aptipedia Aptitude Encyclopedia 2 Ed Wiley 9788126569502 , Excel Quantitative Apititude Arun Sharma 9789355327970 , Verbal Ability And Reasoning For Competitive Examinations Anand Lalit Singh 9788126554294 , Intermediate Engligh Grammer With Answers, 2Ed Murphy 9788185618517 , Design Thinking Teun Den Dekker 9781032786018 , Spotting Errors Lakshminarayanan Bks670723
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 3
5.
Rural Development #11141295 Price Bid
Tender For Lift Irrigation Scheme At Vihir (V.P.Lake) Tal. Akole, Dist. Ahilyanagar.- 1 Sub work no. 1 : Flooting PumpItem no. 1 : Designing, Manufacturing, Providing, Supplying and installing the floating platform suitable for operation & operation in inland water confirming Indian register of shipping rules for dump barge/Pontoon including forming suitable base for installation.Pontoon for 2 Nos of Submersible Pump Set 10 BHPPontoon Size 3 x 3 M 2 Item no. 2 : Designing, Manufacturing, Providing, Supplying and installing the HDPE Walkway. Size - 0.5x0.5x0.4 mtr Weight of the pontoon - 28kg /sq m (+/- 5%), Capacity- 350 kg/ sq m, Mass density not less than 0.953 g/cm3, Colour-Blue/ Grey,MOC- 100% Virgin Grade HD.Walkway 3 Item no. 3 : Supply and Installation of SS flexible. MOC - SS, Length - 6 mtr,SS Single braided with both side MS flange fitting.Pipe Dia 100 MM 4 Item no. 4 : Supply and Installation of Pipe Floater, Shell : High impact Polyethylene , PU foam filled, UV stabilized Raw Material, Color : Orange.Pipe Floater 5 Item no. 5 : Supply and Installation of marine chainChain Dia ( 8 mm ) 6 Item no. 6 : Supply and Installation of RCC BlockAnchor Block 7 Sub work no. 2 : Pump HouseItem no. 1 : Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 8 Item no. 2 : Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distace of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 9 Item no. 3 : Providing and laying in situ following grades of Plain Cement concrete of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including normal dewatering, form work, compaction and curing, etc, complete. Use of L & T, A.C.C.,Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.)PCC 1:2:4 (M-150) 10 Item no. 4 : Providing uncoursed rubble masonry of trap/ granite/ quartzite/ gneiss stones in cement mortar 1:6 in foundations and plinth of inner walls/in plinth of external walls including bailing-out water manually, striking joints on unexposed faces and watering complete. 11 Item no. 5 : Providing and laying in situ, cement concrete M-15 / 1:2:4 of trap / granite / quartzite / gneiss metal for foundation and bedding including bailing-out water manually, formwork, compacting, covering newly laid concrete by gunny bag, plastic or tarpaulin, curing etc. complete. (Wooden planks / shuttering will not be allowed) Spec. No. : Bd.E.1 Page No. 287 / IS 456:2000 12 Item no. 6 : Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction complete. 13 Item no. 7 : Providing Bricks masonry in cement mortar 1:6 using Iind class Clay bricks in superstructure including striking joints, raking out joints, watering and scaffolding complete. 14 Item no. 8 : Providing and laying Cast in situ/Ready Mix cement concrete M- 20 of trap / granite /quartzite/ gneiss metal as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural complete, with fully automatic micro processor based PLC with steel).with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer/ concrete Batch SCADA enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial SandA) For R.C.C. columns Footing 15 B) For R.C.C. columns 16 C) For R.C.C. Beam & Lintel 17 D) For R.C.C. Chajja 18 E) R.C.C. slabs 19 Item no. 9 : Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.Spec. No.: Bd.L.7 Page No. 369 20 Item no. 10 : Providing internal cement plaster 20mm. thick in two coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing complete. Spec. No. : Bd.L.4 Page No. 368 21 Item no. 11 : Providing and fixing steel frame door of angle 50 x 50 x 6 mm with mild steel bars 16 mm dia. horizontally at 10mm c/c for ventilator portion including iron hold fast boxes for fixing shutters including welding, finishing, painting etc. complete. 22 Item no. 12 : Providing and fixing solid core flush door shutter commercial in single leaf 30 mm thick without ventilator commercial type of exterior grade as per detailed drawings with wrought iron hold fast, stainless steel Hinges and cromium plated fixtures and fastenings and handles on both sides and finishing with oil painting 3 coats complete. Spec. No.: Bd-T-36, Page No. 500 23 Item no. 13 : Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain /obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) 24 Item no. 14 : Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations,slabs, beams columns, canopies, staircase, newels, chajjas,lintels pardis, copings, fins, arches etc. as per detailed designs,drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. 25 Item no. 15 : Providing and laying 25mm to 30mm thick rough Shahabad Stone Flooring and of required width in plain / diamond pattern on a bed of 1:6 C.M. including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning etc. complete. 26 Item no. 16 : Providing and applying white-wash in two coats on old/ new plas­tered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing & brooming down complete. 27 Item no. 17 : Providing & applying washable oil-bound distemper of approved colour and shade to old & new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) complete. 28 Item no. 18 : Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to the plastered surfaces including scaffolding if necessary, excluding primer coat cleaning and preparing the surface, watering for two days complete. 29 Sub work no. 3 : Pumping Machinery (Mechanical Work)Item no. 1 : Providing erecting and giving test of 150 mm dia Submersible Pump sets conforming to IS 8034 and motor conforming to 9283. Pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and Bronze impeller. Motor suitable for working on 415V+10%, 3 Ph., 50 Hz., A.C supply with Cable guard, thrust carbon/fiber bearing to with stand entire hydraulic thrust, waterproof winding shall be provided. The Pump set shall be suitable for direct coupling. Pump shall have suitable outlet as per manufactures design. Anti thrust stream lined non return valve shall be provided with the pump. Suitable suction strainer shall also be provided. 3 core, single/double run copper conductor submersible type flat cable 3m and 2 pairs of erection clamps 65mm width 10mm thick shall be provided along with the pump. Rates per pump up to 8 Stages are as below.A) SubmersiblePump 200 mm dia (with Bronze/ Stainless steel(CF8M) Impeller) up to 8 stages set 30 HP 30 B) Submersible pumpset 10 BHP 150 mm Dia 31 Item no. 2 : Supply rate should be increased per stage for pump with more than 15 stage 32 Item no. 3 : Vertical drop pipe 150 mm GI Heavy Duty 33 Item no. 4 : GI bend B Class 150 mm 34 Item no. 5 : GI TEE B Class 150 mm 35 Item no. 6 : M.S. Flange. 36 Item no. 7 : Rate analysis of Cubical Panel board for Pure water 37 Item no. 8 : a) PVC submersible cable 3 core 35 sq mm 38 b) PVC cable 3.5 core 25 mm 2 (Armoured Cable) 39 Item no. 9 : Auto transformer Starter with air break contactor ( Locally Fabricated ) Cubical Panel Size 1.25 m height X 0.75 m width X 0.45 m deep. 40 Item no. 10 : Sluice Valve (PN - 1.6) 150 mm dia 41 Item no. 11 : Reflux Valve (PN - 1.6) 150 mm dia 42 Item no. 12 : Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP 43 Item no. 13 : Supplying and erecting aluminium strip of required sizes used for earthing on wall and/or any other purpose with necessary aluminium clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. 44 Item no. 14 : Tools 45 Sub work no. 4 : RCC GSRItem no. 1 : Designing (aesthetically), and constructing RCC ground service reservoirs / RCC sumps in M-300 mix. of required capacity including excavation in all types of strata, foundation concrete, container walls, bottom slab top RCC roof slab / or dome, 20 mm thick cement plaster with water proofing compound in CM 1:3 proportion. to inside face of the container,including epoxy paint from inside including refilling and disposing of surplus stuff within lead of 50 M, all labour and material charges, for laying and jointing of pipe assembly for inlet, outlet washout, over flow and bye-pass arrangement consisting of C.I./ M.S. D/F. pipes, specials and valves of given diameters, providing and fixing accessories such as Stainless Steel ladder inside and outside, C.I. Manhole frame and cover, water top slab, B.B. masonry chamber for all valves, ventilating shafts, including giving satisfactory hydraulic test and water tightness test as per IS code and providing three coats of Acrylic emulsion with Silicon additives Paint to all expose surface of structure including roof surface etc. complete as per design data, criteria, obligatory requirements and detailed specifications. A) RCC GSR (MBR) 40,000 Litres 46 B) RCC GSR 20,000 Litres 47 C) RCC GSR 20,000 Litres 48 D) RCC GSR 20,000 Litres 49 Item no. 2 : Providing & supplying ISI standard CI double flanged pipesA) Inlet Pipe & washout pipes 100 mm CID/F 50 B) Inlet Pipe & washout pipes 150 mm CID/F 51 Item no. 3 : Providing and supplying ISI standard CIDF specials of required thickness with 3 coats of approved make epoxy paint (Shalimar, Ciba or Mahindra & Mahindra make) from inside and outside including all taxes (Central and local), octroi, inspection charges, transportation to stores / site, and stacking, etc. complete. 52 Item no. 4 : Providing and supplying double flange sluice valves confirming for IS 2906/14846 including warn gear arrangement as per test pressure stainless steel spindle caps including all statutary duties and taxes such as GST levied by Gol and GoM in all respect , transportation etc complete.Sluce Valve 150mm Dia. 53 Item no. 5 : Lowering laying and jointing in position following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of sluice valves)Sluce Valve 150mm Dia. 54 Sub work no. 5 : Raising MainItem no. 1 : Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspection charges of TPI Agency approved by MJP including Transit insurance, Railway Freight, Unloading from railway wagon, Loading into Truck, Transportation to departmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets.DI Pipe 200 mm Dia K-7 Class 55 Item no. 2 : Providing G.I./P.V.C/HDPE/D.I. Specials as per standard specifications & direction of incharge Engineer. (2.5% of Item No.1) 56 Item no. 3 : Providing, erecting, connecting double flanged short body pattern tye manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS 210 Gr. CF 200 generally conforming in BS 5155, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in Teflon bearings excluding C.C. foundation/ structural steel support confirming to IS 3095-1991.Sluice valves+Sluice valve for washout 150 mm Dia 57 Item no. 4 : Providing & supplying ISI mark CI D/F reflux valve (Non- return valve) of following dia including all taxes (central and local ), railway freight, inspection charges unloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984)Reflux valves 150 mm Dia 58 Item no. 5 : Providing and supplying Air valves as per IS-10845 and MJP’s standard specifications of approved mark and quality of following diameters including all taxes (Central and local), railway fright, inspection charges unloading from railway wagons, loading into truck, transportation upto departmental stores/ site, unloading and stacking etc. complete.Air valves 50 mm Dia 59 Item no. 6 : Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 60 Item no. 7 : Excavation for foundation/ pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back- filling, etc. complete. 61 Item no. 8 : Excavation for foundation/ pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 62 Item no. 9 : Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Lift 0 to 1.5 M 63 Item no. 10 : Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete by all means. (Bd-A-6/259) Chissling 64 Item no. 11 : Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. 65 Item no. 12 : Lowering Laying & jointing D.I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test, etc complete either underground or in vertical position, as directed by Engineer-in-charge.DI Pipe 200 mm Dia K-7 Class 66 Item no. 13 : Lowering laying and jointing in position following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of sluice valves)Sluice valves+Reflux valve+Sluice valve washout 150 mm Dia 67 Item no. 14 : Lowering, Laying and fixing in proper alignment and position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete.Air valves 50 mm Dia 68 Item no. 15 : Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.)upto 150 mm on Murum & harder strata 69 Item no. 16 : Providing and laying in situ following grades of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing etc. complete.a) 1:2:4 (M-150) grade for Thrust Blocksb) 1:2:4 (M-150) grade for encasing 70 Item no. 17 : Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5 proportion 12 mm thick cement plaster in cm 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or cm thick slab etc. complete as directed by Engineer-in-charge.Size 0.90 x 0.60 x 1.20 m 71 Item no. 18 : Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete 72 Item no. 19 : Hydraulic testing of D. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments,labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.DI Pipe 200 mm Dia K-7 Class 73 Sub work no. 6 : Gravity Main SystemItem no. 1 : Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.A) 160 mm Dia HDPE Pipe 6 Kg/sqcm 74 B) 200 mm DiaHDPE Pipe 6 Kg/sqcm 75 Item no. 2 : Providing G.I./ P.V.C./ HDPE Specials as per standard specifications & direction of incharge Engineer. (3% of Item No.1) 76 Item no. 3 : Providing, erecting, connecting double flanged short body pattern tye manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS 210 Gr. CF 200 generally conforming in BS 5155, Synthetic rubber faced ring secured on disc by retaining ring with stainless steel screw stub shaft of stainless steel riding in Teflon bearings excluding C.C. foundation/ structural steel support confirming to IS 3095-1991.Sluice valves+Sluice valve for washout 100 mm Dia 77 Item no. 4 : Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 78 Item no. 5 : Excavation for foundation/ pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back- filling, etc. complete. 79 Item no. 6 : Excavation for foundation/ pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond area and lifts as below, stacking as directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. 80 Item no. 6 : Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Lift 0 to 1.5 M 81 Item no. 7 : Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. 82 Item no. 8 : Lowering, Laying and Jointing H. D. P. E./ M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part IIA) 160 mm Dia HDPE Pipe 6 Kg/sqcm 83 B) 200 mm DiaHDPE Pipe 6 Kg/sqcm 84 Item no. 9 : Lowering laying and jointing in position following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of sluice valves)Sluice valves+ Sluice valve washout 100 mm Dia 85 Item no. 10 : Providing and laying in situ following grades of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing etc. complete.a) 1:2:4 (M-150) grade for encasing 86 Item no. 11 : Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5 proportion 12 mm thick cement plaster in cm 1:4 proportion on both sides with providing and fixing C.I. manhole frame and cover in RCC 1:2:4 coping or cm thick slab etc. complete as directed by Engineer-in-charge. Size 0.6 x 0.45 x 0.9 m 87 Item no. 12 : Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete 88 Item no. 13 : Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.A) 160 mm Dia HDPE Pipe 6 Kg/sqcm 89 B) 200 mm DiaHDPE Pipe 6 Kg/sqcm 90 Item no. 14 : Providing and fixing board displaying information, such as Name of work, Tender cost, Name of Contractor, Work completion and liability period etc, having rectangular shape of 1.20 m x 0.90 m size made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border /messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65 m long painted withal ternate black and white bands of 25 cm width including all fixtures etc. and fixing the boards in1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, transportation, and labour etc complete.Spec. Number As directed by Engineer in Charge MORTH 801 Please Enable Macros to View BoQ information
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
7.
Drinking Water Supply and Sanitation #11087677 Price Bid
Tender for E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026. , M 1055 - Pumps Supplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. , Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages 1 H.P. , 1.5 Hp , 2.5 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages , 1.5 Hp , 2.0 Hp , 3.0 Hp , 4.0 Hp , 5.0 Hp , 6.0 Hp , 7.5 Hp , M 1056 - Pressure Guage Providing Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint , Pressure Gauge (100 Mm Dia) , Pressure Gauge (150 Mm Dia) , Vacuum / Combination Gauge , M 1057 - Lifting Equipment Chain Pulley Block Supplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. , 1 Tonne Capacity , 2 Tonne Capacity , 3 Tonne Capacity , Electric Operated Circular Or Rectangular Travelling Crane (Single Girder) Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. , 5 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , 7.5 Tonne Capacity , Above 6 M Upto 8 M Span , Above 8 M Up To 10 M Span , 10 Tonne Capacity , Above 6 M Up To 8 M Span , Above 8 M Up To 10 M Span , M 1058 - Lightening Arrester, Ab Switch, Insulators , Lightening Arrestor Supplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. , Suitable For 11 Kv Supply, Distribution Class , Suitable For 22 Kv Supply, Distribution Class , Suitable For 33 Kv Supply, Station Class , Disc Insulator. Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Pin Insulator Supplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm , Suitable For 11Kv Line , Suitable For 33Kv Line , Air Break Switch Without Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11Kv Line , Rocking / Tilting Type , Rotating Type , Suitable For 33Kv Line , Rocking / Tilting Type , Rotating Type , Air Break Switch With Earth Switch Supplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps , Suitable For 11 Kv Line , Rotating Type , Suitable For 33 Kv Line , Rotating Type , Drop Out Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units , Suitable For 11 Kv Line , Suitable For 33 Kv Line , M 1059 - Transformer Power Transformer (With Off Load Tap Changer) Any Isi Mark , Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. , Power Transformer 11000/433 Volts With Off Load Tap Changer - 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. , 63 Kva , 100 Kva , 160 Kva , 200 Kva , 250 Kva , 315 Kva , 500 Kva , 630 Kva , 750/800 Kva , Power Transformer (With On Load Tap Changer) Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- , 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge. 2. Silica Gel Dehydrating Breather Charged With Silica Gel. 3. Oil Drain Valve 4. Oil Filter Valve 5. Lifting Eyes/ Hooks 6. Two Earthing Terminals 7. Diagram And Rating Plate 8. Air Vent 9. Explosion Vent 10. 100Mm Dia Thermo Meter With Thermometer Pocket 11. Four arc-biannual rate contract Directional Plain Roller. 12. Buchholz Relay 13. Resistance Temp. Detector 14. Marshalling Box 15. Automatic Voltage Regulator (Avr) 16. Remote Tap Changing Controller (Rtcc) , Transformer 11000/433 Volts With On Load Tap Changer - 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification , 750/800 Kva , 1000 Kva , 1250 Kva , 1600 Kva , 2000 Kva , M 1060 - Motors Foot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With F Class Insulation Temperature Rise Limited To Class B Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. , 15 Kw (20 Hp) , 18.5 Kw ( 25 Hp) , 22 Kw ( 30 Hp) , 30 Kw ( 40 Hp) , 37 Kw ( 50 Hp) , 45 Kw ( 60 Hp) , 55 Kw ( 75 Hp) , 75 Kw ( 100 Hp) , 90 Kw ( 120 Hp) , 110 Kw ( 150 Hp) , 132 Kw ( 180Hp ) , 160 Kw ( 215 Hp ) , M 1061 - Aluminium Cable Cable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150 Sq Mm , 3 Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulated Supplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core150sq Mm , 3 Core 185 Sq Mm , 3 Core 240Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1062 - Copper Cable Cable , 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable . Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3 .5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3 .5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor 3.5 Core Xlpe/Pvc Unarmoured Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3.5 Core 25 Sq Mm , 3.5 Core 35 Sq Mm , 3.5 Core 50 Sq Mm , 3.5 Core 70 Sq Mm , 3.5 Core 95 Sq Mm , 3.5 Core 120 Sq Mm , 3.5 Core150sq Mm , 3.5 Core 185 Sq Mm , 3.5 Core 240Sq Mm , 3.5 Core 300 Sq Mm , 3.5 Core 400 Sq Mm , Copper Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable . Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. , 3 Core 1.5 Sq Mm , 3 Core 2.5 Sq Mm , 3 Core 4 Sq Mm , 3 Core 6 Sq Mm , 3 Core 10 Sq Mm , 3 Core 16 Sq Mm , 3 Core 25 Sq Mm , 3 Core 35 Sq Mm , 3 Core 50 Sq Mm , 3 Core 70 Sq Mm , 3 Core 95 Sq Mm , 3 Core 120 Sq Mm , 3 Core 150Sq Mm , 3Core 185 Sq Mm , 3 Core 240 Sq Mm , 3 Core 300 Sq Mm , 3 Core 400 Sq Mm , M 1063 - Foot Valve Supplying C.I. Foot Valve Having Single Leather Flap And Gunmetal Seating. Valve Shall Be Fixed On Suction Side Of Pump As Per Requirement Including Jointing Material And Hardware. , Flanged Type , 50 Mm , 65 Mm , 80 Mm , 100 Mm , 125 Mm , 150 Mm , M 1064 - Air Circuit Breaker Acb Breaking Capacity 50Ka Thermal Magnetic Manual Draw Out Type 3 Pole , 1000A , 1250A , 1600A , 2000A , M 1065 - Starter D.O.L. Starter With Ss Enclosure With 380/415 Volt Coil , 5 To 10 Hp , Supplying Fully Automatic Star Delta Starter To Operate Induction Motor Working On 415V,3Phase,50 Hz With No Volt Coil, Over Load Element, On-Off Push Buttons, With Necessary Materials And Connected To Supply, Etc Complete Starter With Original Sheet Steel Encloser F.A.S.D Starter , 10 Hp , 20 Hp , 25 Hp , 40 Hp , 50 Hp , 75 Hp , 100 Hp , 125 Hp , 150 Hp , 250 Hp , M 1066 - Servo Controlled Automatic Voltage Stabilizer Providing, Erecting Servo Controlled Automatic Voltage Stabiliser Suitable For Out Put Voltage Of 415 Volt ± 1%, 3 Ph, 50 Hz, With Copper Wound Transformer (Air/Oil Cooled) As Mentioned Below. The Stabilizer Shall Function Satisfactorily Even If Incoming Supply Is Unbalanced Between Phases Within Range Of 10%. The Stabilizer Should Be Constructed In Cubical Box, With Bidirectional Wheels For Easy Handling, Necessary Monitors And Users Controls On Front Panel Such As Indication, Alarm, Volt Meter And Selector Switch For Measuring Input And Out Put Voltage, Auto/Manual Selector Switch, Raise/Low Push Buttons Etc. Suitable Capacity Termination Strips And Bus Bars For Incoming And Out Going Cable Should Be Provided. All Three Phases Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated 􀂌 Over Voltage / Under Voltage 􀂌 Single Phasing 􀂌 Cut Off Contactor With Electronic Output Sensing Unit , Servo Controlled Automatic Voltage Stabiliser(Out Put 415 ± 1%) Input 150 / 220 To 450 / 460 Volt , 30 Kva Air Cooled , 40 Kva Air Cooled , 50 Kva Oil Cooled , 60 Kva Oil Cooled , 75 Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , Servo Controlled Automatic Voltage Stabiliser (Out Put 415 ± 1%) Input 280 To 450/460 Volt , 15 Kva Air Cooled , 20 Kva Air Cooled , 30 Kva Air Cooled , 40 Kva Air Cooled , 50Kva Air Cooled , 60 Kva Oil Cooled , 75Kva Oil Cooled , 100 Kva Oil Cooled , 125 Kva Oil Cooled , 150 Kva Oil Cooled , 200Kva Oil Cooled , M 1067 - Termination Kit Providing And Errecting In-Door Type Termination Kit, For 3.3Kv/ 6.6 Kv / 11Kv/ 22Kv/33Kv Xlpe Screened 3 Core Cable , In-Door Termination Kit For 3.3Kv(E/Ue) / 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out-Door Termination Kit For 3.3(E/Ue)/6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 3.3Kv(E/Ue)/ 6.6 Kv(E) Xlpe 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 11Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 11 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-300 Mm² , In Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 22Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-120 Mm² , 150-185 Mm² , 240-400 Mm² , Straight Through Joint For 22 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-150 Mm² , 185-240 Mm² , 300-400 Mm² , In Door Termination Kit For 33Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Out Door Termination Kit For 33 Kv(E) Xlpe Screened 3 Core Cable , 25-50 Mm² , 70-95 Mm² , 120-185 Mm² , 240-400 Mm² , Straight Through Joint For 33 Kv(E) Xlpe Screened 3 Core Cable , 35-70 Mm² , 95-150 Mm² , 185-240 Mm² , 240-300 Mm²
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
8.
Coal and Mines #11041956 AOC
Outsourcing Of Painting Of Machinery / Equipment At Alp Mine-1. M.S. Bolts & Nuts 2. Rivets, Washers & Screws 3. Dog Nails 4. Fish Plates, Nuts & Bolts For Fish Plates 5. Belt Jointing Pins 6. Cable Hooks And Signal Hooks 7. Belt Conveyor Rollers 8. Belt Sections 9. Resin Capsules 10. Cement Capsules 11. Gi Canisters 12. Blasting Gallery – Spacers 13. Radiator Repairs 14. Repairs And Rewinding Of Motors Of Ac & Dc 15. Repairs / Rewinding Of Transformers ( Welding / Lighting / Power ) 16. Gi Wire 17. Wire Mesh For Longwall Salvage 18. Manufacturing Of Supply Of Electrical Coils For Ac Motors Up To 6.6 Kv Grade And Transformer Coils Up To 33 Kv Grade 19. Repairs Of Rotors For Electric Motor 20. Lighting Cable 21. Steel Chock Manufacturing 22. House Wiring 23. All Types Of Fan Repairs 24. Shovel Bucket Welding 25. Repairs Of Pumps 26. Couplings Manufacturing 27. Special Steel And Alloy Castings ( Tooth Points, Track Pads, Mn Steel Casting ) 28. Manufacturing Of Fly Ash Bricks. ( Not To Be Manufactured At Stores Site. It Shall Be At Their Own Site ) . 29. Manufacturing Of Pump Components ( Spares ) . 30. Transformer Oil Filtration 31. Reconditioning Of Drill Bits And Drill Rods 32. Vulcanizing The Old Trailing Cables Of Drill Machines, Sdls, Lhds, Etc. ( Work Should Be Carried Out At The Respective Mine Premises ) . 33. Manufacturing Of Earth Clams, G.I Flats, G.I Bolts And Nuts. 34. Manufacturing Of Earth Pit Components And Erection. 35. Crimping Of Hydraulic Hoses. 36. Repairs To Hydraulic Pumps, Motors, Control Valves And Other Related Components 37. Refurbishing Of Lt & Ht Switches With Oem Spares Including Testing. 38. Manufacturing / Repairs Of Slip Rings & D-Contacts. 39. Furniture Repairs I.E., Cane Chairs, Table, Almirahs, Etc. 40. Repairs To Wet Grinders, Water Purifiers, And Water Coolers 41. Manufacturing Of Coupling Bolts Of All Sizes 42. Fabrication Of Oht Line Components Like Cross Arms, Clamps, Stay Wires, Cross Brassings, Base Plates Etc. 43. Manufacturing Of Haulage Rope Drum Rollers. 44. All Sizes Of Ventilation Doors.
Contract Date: Ref. Documents Contract Value : 67,980
Government Departments No of Bidders 1
9.
Rural Development #10906888 Price Bid
Tender for Providing Material To Gp Munjewadi For Constructing K.T.Weir @Munjewaadi As Per Following Boq To Gp Munjewadi, Tal.Jamkhed, Dist.Ahilyangar , Providing Following Material , Item No. 1 :Excavation In All Kinds Of Soils & Soft Murum Including Boulder Up To 0.6M Diameter (0.113Cum ) For Canal, Seating Of Embankment, Filter Drain / Catch Water Drain Etc. And Placing The Excavated Stuff Neately In Dump Area Or For Formation Of Service Road/ Embankment As Directed Including Cost Of All Material,Labour , Dressing Bed And Sides To The Require Level And Profile Etc. Complete With All Leads 15.0M And Lifts 6.0M As Per Specification. , Item No. 2 :Excavation In Hard Murum Including Boulder Up To 0.6M Diameter (0.113Cum ) For Canal, Seating Of Embankment, Filter Drain / Catch Water Drain Etc. And Placing The Excavated Stuff Neately In Dump Area Or For Formation Of Service Road/ Embankment As Directed Including Cost Of All Material,Labour , Dressing Bed And Sides To The Require Level And Profile Etc. Complete With All Leads 15.0M And Lifts 6.0M As Per Specification. , Item No. 3 :Excavation In Soft Rock Without Blasting Including Boulder Up To 0.6M Diameter (0.113Cum ) For Canal, Seating Of Embankment, Filter Drain / Catch Water Drain Etc. And Placing The Excavated Soft Rock Neately In Dump Area Or For Formation Of Service Road/ Embankment As Directed Including Cost Of All Material,Labour , Dressing Bed And Sides To The Require Level And Profile Etc. Complete With All Leads 15.0M And Lifts 6.0M As Per Specification. , Excavation In Hard Rock Of All Toughness By Blasting Including Boulders Above 0.6 M Dia.(0.113Cum) Minimising Damage To Side Slopes Of Excavation In Water Prism Area By Adopting Any One Or Combination Of Line Drilling/Pre-Splitting/Smooth Blasting Techniques And Placing The Excavated Rock Neatly In Approved Dump Area As Directed Including Cost Of All Materials, Machinery, Labour, Leveling Bed Etc., Complete With Lead Up To 15 M And Lift Up To 6 M. , Providing And Laying In Situ Cement Concrete Of Grade M-15 Of Trap / Granite / Gneiss / Quartzite / Graded Metal For Foundation And Bedding With Concrete Mixer Including Placing, Compacting, Curing With An Initial Lead Of 1 Km And All Lifts Etc. Complete As Directed.(A) M-15 (20 Msa) (Cement 5.64 Bags/Cum) , Providing Fabricating And Placing In Position Reinforcement Steel For Reinforced Cement Concrete Work Including Cutting, Bending, Hooking, Laying In Position And Tying M.S./ Hysd / Tmt Bars For Reinforcement Of As Per Detailed Drawing Etc. Complete As Directed. . , Providing And Fixing Straigh Needle K.T.Weir Gate-Manufacturing - Manufacturing With Qqp & Fabrication Of Kt Weir Needle Gate-Straight Type Size 2.15 X 0.5M-94 Kg. Weight As Per Relevant Indian Standards With All Metrial, Mild Steel Confirming To Is 2062, Rubber Seal Confirming To Is 4623 & Welding Electrodes Aws E6013 For General Weld Jonints, It Includes All Material, Labour Charges, Machinery Charges, J Km Lead Charges Of Transportation, Loading And Unloading Charges Of Gate Parts As Site, Inspection & Qulity Control Charges, Sand Blasing, Painting With One Coat Of Zinc Rich Primer On Dry Film To Give Total Dry Film Thickness 70 + -5 Microns And Coats Of Sloventless Coat Tar Epoxy Paint Applied To Give Minimum Dry Film Thickness Of 150+-5 Micron Per Coat As Per Is 14177. , Providing & Fabricating Structural Steel Work In Rolled Section Like Joist, Channels, Angles, Tees Tec. As Per Detailed Disign & Drawing Including Fixing In Pisition Without Anti Corrosive Paint &Over It Two Coat Of Oil Paint Of Approved Quality And Shade Etec.Complete. , Providing And Fixing Canal Information Board Of 1.2 X 0.75 M Prepared On16 Gauge M.S. Sheet With Angle Iron Frame Of Size 35 X 35 X 3 Mm With Cross Bracing Of Size 25 X 25 X 3 Mm Including Painting With One Coat Of Zinc Chromate Storing Primer And Two Coats Each Of Green/White Back Ground And Back Side Grey Store Enameled Bonded With Red Retro Reflective Sheet Engineering Grade, Border/ Letters/ Numeral/ Arrows Coated With Non Peal Able Crystal Clear Protective Transparent Coat Retaining 100% Reflection Including Two Angle Iron Post Of Size 50X50x5 Mm Of 3.65 M Long Inflated At Bottom Drilled On Top And Painted In White And Black Bonds Of 30 Cm With Four Numbers High Strength Of G.I. Bolts And Nuts Of Size10 Mm Dia. And 20 Mm Long Sheet And Angle Iron Post In One Piece Without Joints Including All Taxes, Conveying, Fixing In Ground With Cement Concrete In M-15 Block Of Size 60 X 60 X 75 Cm As Directed By Engineer- In-Charge. , Nala Degradation
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
Maharashtra View Result →
10.
Housing Urban and Rular Development #10900458 Technical Bid
Tender For Stage Contract For Sub Division Chadoora. (Adv.Cost= Rs 17.00 Lacs)- 1 Engagements Of Jcb For Execuation Of Works Of Various Natures 2 Surface Dressing Of The Ground Including Removing Vegetation And Inequalities Not Exceeding 15 Cm Deep And Disposal Of Rubbish, Lead Upto50 M And Lift Upto 1.5 M In -All Kinds Of Soil 3 Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) In Trenches For Foundations, Drains, Pipes, Cables Etc. (Not Exceeding 1.5 M In Width) And For Shafts, Wells, Cesspits And The Like Not Exceeding 10 Sqm On Plan, Including Dressing Of Sides And Ramming Of Bottoms Lift Upto 1.5 M, Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, ( All Kinds Of Soil) 4 Earth Work In Bulk Excavation By Mechanical Means (Hydraulic Excavator) Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 M2 On Plan) Including Disposal Of Excavated Earth Lead Upto 50 Meters And Lift Upto 1.5 M, As Directed By Engineer-In-Charge. All Kinds Of Soil : 5 Earth Work In Excavation By Manual Means In Trenches For Foundations, Drains, Pipes, Cables Etc .Upto Required Depth ) And For Shafts, Wells, Cesspits Including Dressing Of Sides And Ramming Of Bottoms , Including Getting Out Excavated Earth And Disposal Of Surplus Excavated Earth As Directed, ( All Kinds Of Soil), 1 M From Cutting Edge 6 Providing & Laying Of Stone Soling Tightly Hand Packed Including Watering, Ramming And All Other Carriages, Complett Job 7 Supply And Filling Of Khak Bajri/ Nallah Muck Including Spreading, Watering, Ramming, Compacting With Prr Of 8 To 10 Tonne Capacity Including Carriage Of The Same From Approved Source Upto Site Of Work Complete For Berms Etc 8 Providing / Laying Of Rcc Pipes In Proper Position/ Grade Including Cutting Of Road Surface Upto Required Depth, Providing Requisite Cushion Including Carriage Of All Materials And Pipes Upto Site Of Work Complete Of Different Dia 9 9 Dia 10 12 Dia 11 18 Dia 12 24 Dia 13 36 Dia 14 32\Dia 15 40 Dia 16 Providing / Laying Of Ms Pipes In Proper Position/ Grade Including Cutting Of Road Surface Upto Required Depth, Providing Requisite Cushion Including Carriage Of All Materials And Pipes Upto Site Of Work Complete. 17 6 Dia 18 8 Dai 19 10 Dia 20 12 Dia 21 Scarifying Metalled (Water-Bound) Road Surface Including Disposal Of Rubbish Lead Upto 50M And Consolidation Of The Aggregate Received From Scarifying With Power Road Roller Of 8 To 10 Tonne Capacity 22 Providing Laying Watering And Compacting With (80-100) K.N Road Roller Gsb Filling Having Aggregate Size Not Exceeding 90Mm Granular Sub Base Material To Specified Lines, Grades Cross Sections All Inclusive Leads, Lifts, Loading, Unloading, Head Load If Any And Carriage Of Materials From Nearest Approved Source To Site Of Work Complete. Finished Work To Be Measured And Paid. 23 Supply, Stacking, Laying, Spreading And Compacting Of Graded Stone Aggregate Of (63Mm To 45Mm Size) Wbm G-Ii In Uniform Thickness Including Rolling With Prr 8-10 Capacity In Stages To Proper Grade And Camber Applying And Brooming Requisite Type Of Stone Screenings 13.2Mm Size And Binding Material To Fill Up The Interstices Of Coarse Aggregate Watering Compacting To Required Density (Finished Work Shall Be Paid) With All Leads, Lifts And Carriages As Involved From Source Up To Site Of Work Complete Job. 24 Providing, Laying, Spreading And Compacting Graded Stone Aggregate (Size Range 53Mm To 0.075 Mm) To Wet Mix Macadam Specification Including Premixing The Material With Water At Omc In Mechanical Mix Plant, Transporting The Mix Material By Mechanical Transport From The Plant Upto The Site Of Work, Laying The Mixed Material In Uniform Layers With Mechanical Paver Finisher On Well Prepared Surface And Compacting The Same With Vibratory Roller Of 8 To 10 Tonne Capacity To Achieve The Desired Density / Compaction As Per Specifications And Directions Of Engineer Incharge, Including Cost And Carriage Of All Materials, Hire Charges Of Machinery, All Taxes Etc Complete 25 Scarifying The Existing Bituminous Road Surface To A Depth Of 50Mm And Disposal Of Scarified Material Within All Lifts And Lead Upto 1 Km (By Mechanical Means). 26 Providing And Applying Of Tack Coat Using Hot Straight Run Bitumen Of Grade Vg 10 @ 0.75 Kg / Sqm ( On Wbm Surface Surface) Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler Cleaning And Preparing The Xisting Road Surface As Per Specification Including Cost And Carraige Of All Materials Upto Site Of Work Complete Carraige Of All Materials Upto Site Of Work Complete 27 Providing And Applying Of Tack Coat Using Hot Straight Run Bitumen Of Grade Vg 10 @ 0.5Kg / Sqm ( On Bt Surface Surface) Including Heating The Bitumen, Spraying The Bitumen With Mechanically Operated Spray Unit Fitted On Bitumen Boiler Cleaning And Preparing The Xisting Road Surface As Per Specification Including Cost And Carraige Of All Materials Upto Site Of Work Complete Carraige Of All Materials Upto Site Of Work Complete 28 Providing And Laying 50Mm Thick Bituminous Macadam Base Course With Stone Aggregate Of Quarry, Size And Grading As Specified In Cpwd Specifications And Bitumen Of Grade Vg 10 @ 3.3% By Weight Of Total Mix Including Hot Mixing Of Stone Aggregate And Bitumen In Hot Mix Plant, Transporting The Mixed Material From Plant Upto Site Of Work And Laying The Mixed Material With Paver Finisher To The Required Level And Grade, Rolling With Road Roller Of 8 To 10 Tonne Capacity To Achieve The Required Compaction And Density Including Cost And Carriage Of All The Materials, Hire Charges Of Machinery, All Taxes Etc Complete 29 Providing And Laying Of 25Mm Thick (Compacted) Semi Dense Bituminous Concrete Surface Using Crushed Stone Aggregate Of Specified Grading As Per Specification And Bitumen Of Grade Vg 10 @ 5% By Weight Of Total Mix Including Hot Mixing Of The Stone Aggregate And Bitumen In Hot Mix Plant, Transporting The Mixed Material From Plant Site By Mechanical Transport Upto The Site Of Work, Laying The Mixed Material With Paver Finisher To Required Level And Grade And Rolling With Road Roller As Per Morth Specification To Achieve The Desired Compaction / Density Including Cost And Carriage Of The All Materials, Hire Charges Of Machinery, All Taxes Etc Complete 30 Providing And Laying 6Mm Thick Seal Coat Of Premixed Fine Aggregate (Passing 2.36Mm And Retained On 180 Micron Sieve) With Bitumen Using 126 Kgs Of Bitumen Of Grade Vg 10 Bitumen Per Cum Of Fine Aggregate And 0.60 Cum Of Fine Aggregate Per 100 Sqm Of Road Surface (I.E, 0.768 Kg Of Bitumen Per Sqm Of Road Surface) Including Hot Mixing Of Fine Aggregate And Bitumen In Hot Mix Plant, Transporting The Mixed Material From Plant Site By Mechanical Transport Upto Site Of Work, Laying The Mixed Material With Paver Finisher To Required Level And Grade, Rolling With Road Roller To Achieve Desired Compaction Including Cost And Carriage Of All The Materials, Hire Charges Of Machinery, All Taxes Etc Complete 31 P/L In Position Cement Concrete In 1 : 4 : 8 (1 Cement : 4 Coarse Sand : 8 Graded Crushed Stone Aggregate, 40Mm Nominal Size) Excluding The Cost Of Centering And Shuttering But Including Carriage Of All Materials From Approved Sources Up To Site Of Work Complete. 32 P/L In Position Cement Concrete In 1 : 3 : 6 (1 Cement : 3 Coarse Sand : 6 Graded Crushed Stone Aggregate, 20Mm Nominal Size) Excluding The Cost Of Centering And Shuttering But Including Carriage Of All Materials From Approved Sources Up To Site Of Work Complete, All Works Upto Plinth Level 33 Providing And Laying Cement Concrete In 1 : 3 : 6 (1 Cement : 3 Coarse Sand : 6 , 20 Mm Crushed Graded Stone Aggregates) In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etc Upto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With, Including Carriage Of All Materials 34 P/L In Position Cement Concrete In 1 : 2 : 4 (1 Cement : 2 Coarse Sand : 4 Sand) Graded Crushed Stone Aggregate, 20Mm Nominal Size) Excluding The Cost Of Centering And Shuttering But Including Carriage Of All Materials From Approved Sources Up To Site Of Work Complete, All Works Upto Plinth Level 35 Providing And Laying Cement Concrete In 1 : 2 : 4 (1 Cement : 2 Coarse Sand : 4 Stone Aggregates) In Retaining Walls, Return Walls, Walls (Any Thickness) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchors Blocks, Plain Window Sills, Fillets Etc Upto Floor V Level, Including Curing But Excluding The Cost Of Centring, Shuttering And Finishing With, Including Carriage Of All Materials 36 Providing And Laying In Position In 1:1.5:3 (1 Cement : 1.5 Coarse Sand : 3 Crushed Stone Aggregates) Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level, Including Carriage Of All Materials 37 Reinforced Cement Concrete Work In Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement Using 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size), Including Carriage Of All Materials 38 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With 1:1½:3 (1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size), Including Carriage Of All Materials 39 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For 40 Foundations, Footings, Bases Of Columns Etc. For Mass Concrete 41 Walls (Any Thickness) Including Attached Pilasters, Buttresses, Plinth And String Courses Etc. 42 Suspended Floors, Roofs, Landings, Balconies And Access Platforms 43 Columns, Pillars, Piers, Abutments, Posts And Struts 44 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto And Abone Plinth Level Using Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More, Including Carriage Of All Materials 45 50Mm Thick Cement Concrete Flooring 1:2:4 (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) Finished Wit A Floating Coat Of Neat Cement Including Carriage Of All Materials From Approved Sources Upto Site Of Work Complete 46 40Mm Thick Cement Concrete Flooring 1:2:4 (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) Finished Wit A Floating Coat Of Neat Cement Including Carriage Of All Materials From Approved Sources Upto Site Of Work Complete 47 25Mm Thick Cement Concrete Flooring 1:2:4 (1 Cement: 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size) Finished Wit A Floating Coat Of Neat Cement Including Carriage Of All Materials From Approved Sources Upto Site Of Work Complete 48 12Mm Cement Plaster Of Mix 1 : 4 ( 1 Cement : 4 Fine Sand), Including Carriage Of All Materials 49 Random Rubble Masonry With Quarry Hard Stone In Foundation And Plinth Including Leveling Up With Cement Concrete 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20Mm Nominal Size) Upto Plinth Level And Curing Complete With Cement Mortar 1:6 (1 Cement : 6 Coarse Sand), Including Carriage Of All Materials 50 Random Rubble Masonry With Quarry Hard Stone In Superstructure Above Plinth Level And Upto Floor Five Level, Including Levelling Up With Cement Concrete In 1:6:12 (1 Cement : 6 Coarse Sand : 12 Graded Stone Aggregate 20Mm Nominal Size) And Curing Complete At Window Sills, Ceiling Level And The Like In Cement Mortar 1:6 (1 Cement : 6 Coarse Sand), Including Carriage Of All Materials 51 Dry Random Rubble Masonry With Quarry Hard Stone In Foundation And Plinth With Bond Stone, Including Carriage Of All Materials 52 Pointing On Stone Work With Cement Mortar 1 : 3 (1 Cement : 3 Fine Sand) : Flush/Ruled Pointing, Including Carriage Of All Materials 53 Backfilling By Way Of 2Nd Class Stones Behind R Walls, Edge Walls, Toe Walls, Drain Blocks Etc Including All Carriages, Complete Job 54 Supplying And Laying Hand Packing Of 2Nd Class Stones/Boulders In Wire Crates Including Cost Of Crates And Stones, All Carriages Involved, Complete Job 55 Supplying And Laying Hand Packing Of Quarry Stones In Wire Crates Including Cost Of Crates And Stones, All Carriages Involved, Complete Job 56 Engagement Of Unskilled Labour /Masdoor For One Day 57 Engagement Of Skilled Labour With All Machinary Like Cutters , Axe Etc For Purning Of The Trees 58 Silt Clearance From Drains (Wet) By Manual Or Mechanical Means Including Disposal Of Rubbish As Directed At Site By The Engineer In Charge Of Site 59 Clearance Of Slips Including Disposal Of Same As Directed By Engineer In Charge Of Site In 60 In Ordinary Soils 61 In Soils; Mixed With Moorum/Kankar/Shingle/Boulders 62 In Soils; Mixed With Decomposed Rocks; By Blasting Or Anyother Means 63 In Medium Hard Rocks ; By Blasting 64 In Hard Rocks; By Blasting 65 Providing & Erecting \W\ Metal Beam Crash Barrier Comprising Of 3 Mm Thick Corrugated Sheet Metal Beam Rail, 70 Cm Above Road/Ground Level , Fixed On Ismc Series Channel Vertical Post, 150 X 75 X 5 Mm Spaced 2 M Centre To Centre, 1.80 M High, 1.1 M Below Ground Level , All Steel Parts And Fitments To Be Galvanised By Hot Drip Process, All Fittings To Conform Is: 1367 And Is: 1364, Metal Beam Rail To Be Fixed On The Vertical Post With A Spacer Of Channel Section 150 X 75 X 5 Mm, 330 M Long, Complete Job, As Per Morth Clause 810, Including Carriage Of All Materials 66 Structural Steel Work In Welded Single Section, Fixed With Or Without Connecting Plate, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete, Including Carriage Of All Materials 67 Structural Steel Work In Welded Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete, Including Carriage Of All Materials 68 Providing And Fixing Hand Rail Of Approved Size By Welding Etc. To Steel Ladder Railing, Balcony Railing, Staircase Railing And Similar Works, Including Applying Priming Coat Of Approved Steel Primer, Gi Pipes, Including Carriage Of All Materials 69 Providing And Fixing Bolts Including Nuts And Washers Complete, Including Carriage Of All Materials 70 Providing And Fixing M.S. Rivets Of Sizes In Position, Including Carriage Of All Materials 71 Welding, Including Transportation Of Plant At Site Etc. Complete 72 By Gas Plant 73 By Electric Plant 74 Painting Road Surface Marking With Adequate No. Of Coats To Give Uniform Finish With Read Mixed Road Marking Paint Conforming To Is: 164, On Bituminous Surface In White/Yellow Shade Including Cleaning The Surface Of All Dirt, Scales, Oil, Grease And Foreign Material Etc. Complete 75 New Work (Two Or More Coats) 76 Old Work ( One Or More Coats) 77 Providing And Laying Design Mix Cement Concrete Of M-30 Grade, In Roads/Taxi Tracks/ Runways, Using Cement Content As Per Design Mix, Using Coarse Sand And Graded Stone Aggregate Of 40 Mm Nominal Size In Appropriate Proportions As Per Approved & Specified Design Criteria, Providing Dowel Bars With Sleeve/ Tie Bars Wherever Required, Laying At Site, Spreading And Compacting Mechanically By Using Needle And Surface Vibrators, Leveling To Required Slope/ Camber, Finishing With Required Texture, Including Steel Form Work With Sturdy M.S. Channel Sections, Curing, Making Provision For Contraction/ Expansion, Construction & Longitudinal Joints ( 10 Mm Wide X 50 Mm Deep) By Groove Cutting Machine, Providing And Filling Joints With Approved Joint Filler And Sealants, Complete All As Per Direction Of Engineer-In- Charge (Item Of Joint Fillers, Sealants, Dowel Bars With Sleeve/ Tie Bars To ,Be Paid Separately), Including Carriage Of All Materials Note:-Cement Content Considered In M-30 Is @ 340 Kg/Cum. Excess/ Less Cement Used As Per Design Mix Is Payable/ Recoverable Separately. 78 Cement Concrete Prepared With Batch Mixing Machine 79 Cement Concrete Manufactured In Automatic Batching Plant(Rmc Plant) I/C Transportation To Site In Transit Mixer 80 Providing And Laying 60Mm Thick Factory Made Cement Concrete Interlocking Paver Block Of M-30 Grade Made By Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/Shape Laid In Required Colour And Pattern Over And Including 50Mm Thick Compacted Bed Of Fine Sand, Filling The Joints With Coarse Sand Etc. All Complete As Per Direction Of Engineer-In-Charge, Including Carriage Of All Materials 81 Providing And Applying 2.5Mm Thick Road Marking Strips (Retro-Reflective) Of Specified Shade/Colour Using Hot Thermoplastic Material By Fully/Semiautomatic Thermoplastic Paint Applicator Machine Fitted With Profile Shoe, Glass Beads Dispenser, Propane Tank Heater And Profile Shoe Heater, Driven By Experienced Operator On Road Surface Including Cost Of Material, Labour, T&P, Cleaning The Road Surface Of All Dirt, Seals, Oil, Grease And Foreignmaterial Etc. Complete As Per Direction Of Engineer-In-Charge And Accordance With Applicable Specifications 82 Providing And Laying C.C. Pavement Of Mix M-25 With Ready Mixed Concrete From Batching Plant. The Ready Mixed Concrete Shall Be Laid And Finished With Screed Board Vibrator, Vacuum Dewatering Process And Finally Finished By Floating, Brooming With Wire Brush Etc. Complete As Per Specifications And Directions Of Engineer-In-Charge. (The Panel Shutteringwork Shall Be Paid For Separately).Note: Cement Content Considered In This Item Is 303 Kg/ Cum Excess/Less Cement Used As Per Design Mix Is Payable/Recoverable Separately 83 Providing And Laying At Or Near Ground Level Factory Made Kerb Stone Of M-25 Grade Cement In Position To The Required Line, Level And Curvature Jointed With Cement Mortar 1:3 (1 Cement: 3 Coarse Sand) Including Making Joints With Or Without Grooves (Thickness Of The Joints Except At Sharp Curve Shall Not To Be More Than 5Mm) Including Making Drainage Opening Wherever Required Complete Etc. As Per Direction Of Engineer-In Charge (Length Of Finished Kerb Edging Shall Be Measured For Payment). (Precast C.C. Kerb Stone Shall Be Approved By Engineer-In-Charge), Including Carriage Of All Materials 84 Manufacturing Supplying And Fixing Retro Reflective Sign Boards Made Up Of 2Mm Thick Aluminum Sheet, Face To Be Fully Covered With High Intensity Encapsulated Type Heat Activated Retro Reflective Sheeting Conforming To Type-Iv Of Astm-D-4956-01 In Blue And Silver White Or Other Colour Combination Including Subject Matter, Message (Bi-Lingual), Symbols And Borders Etc. As Per Irc : 67-2001, Pasted On Substrate By An Adhesive Backing Which Shall Be Activated By Applying Heat And Pressure Conforming To Class -2 Of Astm-D-4956-01 And Fixing The Same With Suitable Sized Aluminum Alloy Rivets @ 20Cm C/C To Back Support Frame Of M.S. Angle Iron Of Size 25X25X3Mm Along With Theft Resistant Measures Mounted And Fixed With 2 Nos. M.S. Angles Of Size 35X35X5Mm To A Vertical Post Made Upto M.S. Tee Section Ismt 50X50X6Mm Welded With Base Plate Of Size 100X100X5Mm At The Bottom End And Including Making Holes In Pipes, Angle Flats, Providing And Fixing M.S. Message Plate Of Required Size Steel Work To Be Painted With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade And Of Approved Brand & Manufacture Over Priming Coat Of Zinc Chromate Yellow Primer (Vertical M.S.-Tee Support To Be Painted In Black And White Colours). Backside Of Aluminum Sheet To Be Painted With Two Or More Coats Of Epoxy Paint Over And Including Appropriate Priming Coats Including All Leads And Lifts Etc. Complete As Per Drawing, Specification And Direction Of Engineer-In-Charge, Including Carriage Of All Materials 85 Mandatory/Regulatory Sign Boards Of 900 Mm Diameter Withpart As Length Of 3750 Mm 86 Cautionary/Warning Sign Boards Of Equilateral Triangular Shapehaving Each Side Of 900 Mm Support Length Of 3650Mm 87 Clearance Of Blocked Cross-Drainage Pipes Including Disposal, Etc. Complete Job 88 Clearance Of Drains Manually By Excavating The Accumulated/Deposited Mulba Silt In Drains And On Either Side Of Shoulders And Cutting Of Vegetations Grass Etc. Including Disposal Of Rubbish Beyond Municipal Limits By Any Means To Make The Drains Functional. 89 Repairing Of Kerb Stones Whereever Necessary Incl. Washing With Detergent And Water Including Cleaning Of Grease / Oil Spots With Appropriate Chemicals. 90 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade, One Or More Coats On Old Work
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
Jammu And Kashmir View Result →
11.
Railways #10882300 AOC
Supply Of Dynamic Wheel Balancing Machine (On Turnkey Basis) As Per Bid Document Part Ii Attached Below. [ Warranty Period: 30 Months After The Date Of Delivery ] ] , Comprehensive Annual Maintenance Contract For Dynamic Wheel Balancing Mac Hine [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 8 % ] ] At (Location) Sse/Wheel/Pl, Wr Maharashtra 1.00 Numbers 3 657933430011 Essential Non Stock --- Yes Tpi Agency Inr Spares (Y) Concomitant Accessories For Dynamic Wheel Balancing Machine As Per Bid Docum Ent Part Ii Attached Below [ Warranty Period: 30 Months After The Date Of Delivery ] ] Consignee Sse/Wheel/Pl, Wr Maharashtra 1.00 Set Inspection Details Stage Inspection Not Required 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply Page 1 Of 7 Run Date/Time: 24/09/2024 15:06:54Stores/Western Rly Tender Document Tender No 11245036 Closing Date/Time 18/11/2024 11:00 For All Items Completion : Within 330 Days Firm Shall Complete The Supply, Installation & Commissioning And Know - How Training To Concern Staff Of Consignee At Consignee Premises Within Stipulated Time Prescribed In Delivery Period. Payment Terms S.No Description Payment Terms 1 80% Payment Shall Be Made On Receipt Of The Items In Satisfactory Condition, Against Suppliers Challan Certiï¬Ed By Consignee Gazetted Oï¬Ƒcer, And Inspection Certiï¬Cate Issued By The Nominated Inspection Agency And After Successful Installation, Commissioning. Balance 20% Payment Shall Be Made After Issue Of Ptc(Proving Test Certiï¬Cate) (To Be Issued After One Month Performance Observation) By Consignee Subject To Submission Of Bank Guarantee For 10% Of The Contract Value For Warranty Obligations, Valid Beyond 6 Months Period Of Warranty. Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 1) The Contract Shall Be Governed By Latest Version (Along With All Correction Slip) Of Irs Conditions Of Contract And All Other Terms And Conditions Incorporated In The Tender Documents. (2) The Contract Shall Also Be Governed By Instructions To Tenderers And General Conditions Of Tender Indigenous Version 14 Of June 2024 Or Latest With All Corrigendums And Amendments, If Any, Issued Before Tender Closing, Available As Public Documents Of Western Railway On Ireps Website (3)(A) It May Be Noted That Conditions Mentioned In Tender Schedule On Ireps Shall Prevail Over General Conditions Of Contract, Which In Turn Shall Prevail Over Irs Condition Of Contract. (B) Terms & Conditions/Speciï¬Cations Mentioned In Nit Shall Prevail Over Conditions Mentioned In Documents Attached With Nit. 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 The Manufacturer Shall Have Valid Iso-9001 Certiï¬Cate On The No No Allowed Original Date Ofclosing Of Tender And A Copy Of Same Should Be (Mandatory) Submitted Along With The Bid (Dynamic Wheelbalancing Machine Shall Be In The Scope Of Iso Certificate). 2 1) The Bidder/ Manufacturer Must Have Supplied At Least 01 No No Allowed Numbers Of The Similar Or Higher Capacity Of Dwbm To Any Of Indian (Mandatory) Railway Production Unit Or Zonal Railways Or Other Government Organizations In Last 05 Years From The Date Of Closing Of Tender. Firm Must Upload Documentary Evidence Regarding The Past Successful Supplies Like Copies Of Receipt Note/Inspection Certiï¬Cate/Installation And Commissioning Report Etc. Along With The OffEr. (2) Performance Certiï¬Cate:Out Of The Item Supplied As Per Clause Above, The Bidder Shall, In Their OffEr, Submit Performance Certiï¬Cate Of At Least 01 Number Of Machine That Must Have Worked Satisfactorily For At Least One Year From The Date Of Commissioning.The Performance Certiï¬Cate Submitted By The Bidder Should Not Be More Than One Year Old I.E. It Should Have Been Issued Within One 01 Year From The Tender Closing Date Issued By The Actual End User Of The Machine. Page 2 Of 7 Run Date/Time: 24/09/2024 15:06:54Stores/Western Rly Tender Document Tender No 11245036 Closing Date/Time 18/11/2024 11:00 3 Firm Shall Submit The Para-Wise/Item-Wise Compliance Of All The No No Allowed Parameters Mentioned In The Technical Speciï¬Cations Mentioned In (Mandatory) The Document Below. If There Is Any Deviation, The Same Shall Be Clearly Indicated In The Deviation Statement. A.Bid Document Part Ii 4 Firm Must Upload Documentary Evidence Regarding The Past No No Not Allowed Successful Supply Performance Like Copies Of Contract Order/Receipt Note/Inspection Certiï¬Cate, Installation And Commissioning Report Jointly Signed With The Actual User/Consignee, Ptc Etc. Along With The Offer, Failing Which The Offer Shall Be Liable To Be Rejected. 5 (1) Procurement Shall Be Done From Manufacturers (Oems) Or No No Allowed Authorized Agent / Dealer Of Oem. (2) Either Oem Should Quote (Optional) Directly Or Oem Can Give Tender Speciï¬C Authorization To Its Agent / Dealer To Quote On Their Behalf. (3) The Authorized Dealer Should Submit Valid Tender Speciï¬C Authorization, Along With The OffEr, Failing Which Their Offer Will Be Summarily Rejected. 6 Earnest Money Deposit (Emd): (1) Emd Shall Be Submitted By No No Allowed Tenderer As Speciï¬Ed In Tender Schedule, Along With Their Online (Optional) OffEr. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Except Those Exempted. (2)Exemption To Submit Emd Will Be Given In The Following Cases : (A) Only Manufacturers Having Valid Udyam Certiï¬Cate Under Micro And Small Category Are Eligible For Exemption From Emd. (B) Other Railways And Government Departments. (C) Indian Ordnance Factories. (D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them. (E) Vendors Registered With Railways For The Trade Group Of The Item Tendered. (F) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core, Subject To Approval Status Being Valid On The Date Of Tender Closing. (G) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables For These Items. (H) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued (I)Kvic And Acash For Items Supplied By Them. 5. Compliance Conditions Commercial-Compliance S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 The Bidder Conï¬Rms That Rates And Other ϬNancial Terms Quoted In No No Not Allowed Relevant Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. (Denial Of This Condition Not Recommended) 2 Make In India Policy :- 1) As Per Clause 1800 Of Instructions To No No Allowed Tenderers And General Conditions Of Tender Indigenous Version 14 (Optional) Of June 2024 Or Latest With All Corrigendums And Amendments, If Any, Issued Before The Tender Closing. 2) The Tender Will Be Governed By Railway Board Letter No.2020/Rs(G)/779/ 2 Dtd. 12/06/20 And 2015/Rs(G}/779/5(Vol.L) Dated 24/09/2020 & 2024/Rs(G)/779/3(E 3464799) Dt.25.06.2024 For Public Procurement (Preference To Make In India) 3 Please Enter The Percentage Of Local Content In The Material Being No Yes Allowed OffEred. Please Enter 0 For Fully Imported Items, And 100 For Fully (Optional) Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. Other Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Inspection By Tpi Agency At Oems Premises . Firm To Quote Place Of No No Not Allowed Inspection Clearly In Their OffEr So As To Enable This Oï¬Ƒce To Incorporate Place Of Inspection In Po.The Machine Shall Be Inspected And Tested During DiffErent Stages Of Its Manufacture Starting From Raw Material Till The Completion Of Machine As Per Annexure-I (Qap) Attached For Reference. Page 3 Of 7 Run Date/Time: 24/09/2024 15:06:54Stores/Western Rly Tender Document Tender No 11245036 Closing Date/Time 18/11/2024 11:00 2 The Machine Shall Be Inspected And Tested During DiffErent Stages No No Allowed Of Its Manufacturing Starting From Raw Material , By The Purchaser (Mandatory) Or His Authorized Representative (Tpi) At The Suppliers Or His Sub- Suppliers Works For Which Bidder Has To Submit Qap Incorporating The Tests Along With Stage Inspections For The Tender Items And Tpi Will Carried Out Inspection At Manufactures Works As Per The Qap (Quality Assurance Plan) 3 Evaluation Criteria: 1) The Inter-Se-Position Of All OffErs Received No No Not Allowed Will Be Decided On Total Value Of Tender Quoted By The Firm. 4 Road Delivery : In Case Of Road Delivery, The Date Of Delivery At No No Not Allowed Destination (Consignees End) Shall Only Be Treated As Delivery Date Irrespective Of F.O.R./F.O.T. Condition Mentioned Elsewhere In The Contract/ Tender. 5 Performance/Bank Guarantee: As Per Clause 0600 Of No No Not Allowed Instructions To Tenderers And General Conditions Of Tender Indigenous Version 14 Of June 2024 Or Latest With All Corrigendums And Amendments, If Any, Issued Before The Tender Closing. 6 Warranty / Guarantee Period:As Per Clause 1200 Of No No Not Allowed Instructions To Tenderers And General Conditions Of Tender Indigenous Version 14 Of June 2024 Or Latest With All Corrigendums And Amendments, If Any, Issued Before The Tender Closing. 7 Neft/Rtgs/Ecs Payment:As Per Clause 2900 Of Instructions To No No Not Allowed Tenderers And General Conditions Of Tender Indigenous Version 14 Of June 2024 Or Latest With All Corrigendums And Amendments, If Any, Issued Before The Tender Closing. 8 Gst Compliance:-As Per Clause 0906 Of Instructions To Tenderers No Yes Allowed And General Conditions Of Tender Indigenous Version 14 Of June (Optional) 2024 Or Latest With All Corrigendums And Amendments, If Any, Issued Before The Tender Closing. 9 Security Deposit (Sd): 1.0 All Successful Tenderer Shall Deposit No No Allowed Security Deposit (Sd) Amount @5% Of Contract Value Rounded Off To (Optional) Nearest Higher Rs.10, Subject To Maximum Rs. 50 Lakhs For Contract Value Up To Rs 50 Cr. In Case Of Contract Value Above Rs 50 Cr. Sd Will Be Rs 1 Cr. 2.0 There Shall Be No Exemption From Submission Of Security Deposit (Sd) For Any Tender Or By Any Tenderer Except Following: I. The Contract Value Up To Rs.25 (Twenty ϬVe) Lakhs. Ii. Other Railways And Government Departments. Iii. Indian Ordnance Factories. Iv. Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them. V. In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued. Vi. Kvic And Acash For Items Supplied By Them. Vii. Vendors Registered With Railways For The Trade Group Of The Item Tendered For Orders Valued Up To Their Monetary Limit Of Registration. Viii. Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core, Subject To Approval Status Being Valid On The Date Of Tender Closing. Ix. Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables For These Items. 3.0 Security Deposit (Sd) Shall Remain Valid For A Period Of 60Days, Beyond The Date Of Completion Of All Contractual Obligations. 4.0 Sd From Successful Tenderer Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Acceptance Letter Issued By Purchaser. In The Event Of Successful Tenderer (S) Failing To Deposit/Submit Sd In Acceptable Form Within The Prescribed Period As Aforesaid, The Emd Submitted By Such Successful Tenderers Shall Be Automatically Adjusted Towards Sd. In Case Where Available Emd Amount Is Less Than Required Sd And The Successful Tenderer Does Not Deposit The Balance Sd Amount Within Stipulated Time, Then Emd Shall Be Forfeited And Case Be Dealt With As That Of Withdrawal Of OffEr By The Tenderer. Page 4 Of 7 Run Date/Time: 24/09/2024 15:06:54Stores/Western Rly Tender Document Tender No 11245036 Closing Date/Time 18/11/2024 11:00 10 Security Deposit (Sd): 5.0 Wherever Sd Has Been Exempted, For No No Allowed Any Reason, And The Supplier Fails To Supply Goods As Per Conditions (Optional) Of Contract, As Amended From Time To Time, Purchaser Shall Have Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By Way Of Penalty, An Amount Equal To Sd Amount, As Would Have Been Applicable If The Contract Was With A Non-Exempted Vendor. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 6.0 Apart From Claiming Damages From Vendors, In Case Of Failure To Comply With The Contractual Obligations, Railways Shall Record Poor Performance Of The Vendors For Taking Suitable Penal Action. 7.0 Sd Can Be Submitted In Following Format: A. Dd In The Name Of Chief Cashier/Wr/Ccg. B. Fixed Deposit Receipt Duly Discharged And Stamped In Favour Of Fa&Cao(S) (Stock Items) Or Fa&Cao(X) (Non Stock Items) Or Fa&Cao(C) Churchgate, Western Railway As The Case May Be. C. Bank Guarantee: In Case Bank Guarantee Is Submitted By Supplier/Contractor, The Same Should Be In The Proper Prescribed Format For Bg As Per Annexure Available On Web Site Www.Ireps.Gov.In Website Link Western Railway/Pcmm. The Stamp Duty Shall Be @Rs.5/- Per Thousand Or Part Thereof For The Amount Secured For Such Deed. The Title Holder Of The Bg Shall Be President Of India Acting Through The Pfa/Ccg.8.0 Risk Purchase Clauses Shall Not Be Applicable. 11 All The Conditions Of Nit Are Available On Ireps Web Site. No No Not Allowed 12 Mse Clause:- (A) (I) Mse Participating In The Tender As Stipulated At No No Allowed Para (B) Below , Will Be Exempted From Payment Off Earnest Money. (Optional) (Ii) In Tenders Participating Mses, As Para (B) Below Quoting As Price Within Price Band Of L-1 + 15% Shall Be Allow To Supply A Portion Of The Requirement By Bringing Down Their Price To L-1 Price In A Situation Where L-1 Price Is From Someone Other Than Mse And Such Mses Can Together Be Ordered Upto 25% Value Out Of The Net Procurement Quantity. (B) (I) Mses, Who Are Interested In Availing Themselves Of These Beneï¬Ts, Will Enclosed With Their OffEr A Copy Of Udyam Registration Certiï¬Cate Only. Mse Beneï¬Ts Will Not Be Admissible Based On Any Other Document. (Ii) Further, As Per Gazette Notiï¬Cation Dt.18.10.2022, Incase Of An Upward Change In Terms Of Investment In Plant And Machinery Or Equipment Or Turnover Or Both, And Consequent Re-Classiï¬Cation, An Enterprise Shall Continue To Avail Of All Non- Tax Beneï¬Ts Of The Category (Micro Or Small Or Medium) It Was In Before The Reclassification, For A Period Of Three Years From The Date Of Such Upward Change. All Mses Shall Be Eligible For Beneï¬Ts Of Public Procurement Policy Irrespective Of Product Category Under With Mses Are Registered. However, Traders/Authorized Dealers Will Not Be Eligible For Such Beneï¬Ts. (Iii)The 25% Quantity Shall Be Considered To Mse Including Quantity For Women Owned Mses & For Sc/St Owned Mses As Per Extant Rules And Only Be Considered If Valid Certiï¬Cate Issued By Nominated Agencies Is Uploaded Along With OffEr. If Documents Are Not Uploaded This Beneï¬T Will Not Be Given Totenderer. Only Oem/Manufacturers Will Be Given Beneï¬T Of Mse, Trader/Authorised Dealer Are Excluded From The Purview Of This Policy 13 Land Border Condition (A): Attention Of The Bidders Is Drawn To Yes Yes Allowed Special Conditions Regarding Restrictions On Procurement From A (Mandatory) Tenderer (Bidder) Of A Country, Which Shares A Land Border With India, Attached With This Tender.Bidders Should Note That Compliance To Land Border Condition (B) Of This Tender Schedule Is Mandatory. Bidders Are Required To Attach Evidence Of Valid Registration, If Applicable To Them. Non-Compliance Shall Result In Summary Rejection Of Their OffEr. Any False Declaration And Non- Compliance Of The Above Would Be A Ground For Immediate Termination Of The Contract And Further Legal Action In Accordance With The Laws. 14 Land Border Condition (B) : I Have Read And Understood Special Yes Yes Allowed Conditions Regarding Restrictions On Procurement From A (Mandatory) Tenderer(Bidder) Of A Country, Which Shares A Land Border With India, Attached With This Tender. I Certify That This Bidder Is Not From Such A Country Or, If From Such A Country, Has Been Registered, With The Competent Authority. I Hereby Certify That This Bidder Fulï¬Ls All Requirements In This Regard And Is Eligible To Be Considered. Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached. Page 5 Of 7 Run Date/Time: 24/09/2024 15:06:54Stores/Western Rly Tender Document Tender No 11245036 Closing Date/Time 18/11/2024 11:00 Special Conditions S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 Special Instructions For Machinery & Plant (M&P) Items : As No No Not Allowed Per Clause 3900 Of Instructions To Tenderers And General Conditions Of Tender Indigenous Version 14 Of June 2024 Or Latest With All Corrigendums And Amendments, If Any, Issued Before The Tender Closing. 2 Delivery Terms: 1) Dispatch Of The Machine: The Supplier Should No No Not Allowed Normally Dispatch The Machine Only After The Foundation Is Ready For Installation And Commissioning Of The Machine On Arrival. General Arrangement, Foundation & Related Drawings Of Machine Will Be Sent By The Firm To The Consignee Before Supply Of Machine For Approval Of Approving Oï¬Ƒcer Of Consignee. 2) Mode Of Dispatch/Delivery: The Supplier Shall Be Responsible For Transportation, Unloading Of The Equipment On Receipt And Its Movement To The Site Of Installation Including Provision Of Road Mobile Crane, Forklift Etc. 3 Marking: Materials Are To Be Invariably Stamped With No No Not Allowed Manufacturers Name, Month & Year Of Manufacture As May Be Detailed In The Drawing/Speciï¬Cation Of The Material, So That Warranty Can Be Correctly Acted Upon. Technical-Compliances S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 1. The Cost Is Inclusive Of Design, Manufacture, Supply, Erection And No No Not Allowed Commissioning, Bidder May Quote Separately Along With Concomitant Accessories And List Of Tools For Each Machine For Successful Operation Of Machine. 2. Calibration Certiï¬Cate Shall Be Provided For Any Kind Of Gauging/Measuring Instrument Installed On Machine With Validity Of 12 Months From The Date Of Commissioning. 3. Before Starting Of Manufacturing Of Machine It Is Required To Submit General Arrangement Drawing For Approval. 4. Before Dispatch Of Machine The Supplier Has To Complete The Foundation Work ( In No Case Machine Will Be Accepted By Consignee If Foundation Is Not Completed) 5. The Machine Will Not Be Accepted At Consignees Premises Unless The Passed Quality/ Quantity Inspection Certificate Of Rites/Inspection Agency Is Produced. 2 Bidders Are Required To Submit Complete Details Including Values, No No Allowed Write-Up, Drawings, Sketch, Brochure Etc. As Per Requirement (Mandatory) Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance Undertakings S.No. Description Confirmation Remarks Documents Required Allowed Uploading 1 1) Price Variation Clause:- Not Applicable. 2)I/We Agree To Supply The No No Not Allowed Tendered Stores At The Rates Quoted By Me/Us In Accordance With The Conditions Mentioned In This Tender & Its Documents And Conditions Available On Ireps. 3) I/We Also Conï¬Rm That Rates And Other ϬNancial Terms Quoted In Relevant Columns Of ϬNancial Bid Will Only Be Applicable For Acceptance. Such Terms Quoted Anywhere Else Shall Not Be Considered For Inter-Se Evaluation 6. Documents Attached With Tender S.No. Document Name Document Description 1 5041595.Pdf Itt & Gcc Version 14 June 2024 2 4674190.Pdf Land Border Condition 3 4674206.Pdf Land Border Condition Amendment 4 4911496.Pdf Delivery Schedule 5 5041600.Pdf Revised Irs Conditions Of Contract_Sept 2022 6 5041674.Pdf Bid Document Part Ii 7 5041680.Pdf Annexure-I(Qap) Page 6 Of 7 Run Date/Time: 24/09/2024 15:06:54Stores/Western Rly Tender Document Tender No 11245036 Closing Date/Time 18/11/2024 11:00 8 4674226.Pdf Tpi Condition The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Smm-M ( Ashok Kumar Meena ) , Concomitant Accessories For Dynamic Wheel Balancing Machine As Per Bid Docum Ent Part Ii Attached Below [ Warranty Period: 30 Months After The Date Of Delivery ] ]
Contract Date: Apr 28, 2026 Contract Value : 50.20 Lakh
Government Departments No of Bidders 1
Maharashtra View Result →
12.
Housing Urban and Rular Development #10803700 Price Bid
E-Quotation No.5 For 2022-23 E Rate Quotation For Preparation Of Ssr For Various Item Which Is Mention In Notice , For Steel Structure / Tmt -Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) For Concrete Surface -Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kleox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Top Terrace Waterproofing -- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Waterproofing Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Waterproofing Of Concrete Surfaces Of Terrace To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Of Existing Terrace Surface Upto Mother Slab Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60Of Dimple Chemicals & Services Pvt. Ltd After Finishing, After Top Coat Application, Pcc Will Be Done Up To 50 Mmthickness ( Or As Per Site Condition ) Of Desire Slope To Drain The Water And Kept Ponded For Continuous Period Of 3 Days To Detect Any Seepage / Leakage / Dampness If Any, The Surface Then Shall Be Cleared, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, After Picc Apply A Poly Ceramic Cementitious Top Coat I.E Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd After Finishing It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System , This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc.As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 10 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas, Lift Jointsetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Concrete Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Scaffolding, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Road Surfaces To A Thickness Upto 15 Mm Or As Per Surface Conditions And Also Treatment Of Pot Holes, Cracksetc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces To A Thickness Upto 25 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Keloxr 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar.Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying Poly Ironite Ceramic Cementitious ( Picc ) Ofdimple Chemicals & Services Pvt. Ltd Ensure Self Curing, High Abrasion Resistant, Non-Shrink, High Compressive Strength, Low Porosity, Uv Resistant Coating Mortar On Existing Well Gsb Of 100 Mm Thickness, Get Compacted Andlevelled , Cure The Surfacethen Applyingself Curing Coating Picc Mortarin Properation Of 1;1 ( Nicomix Series : Metal ) For 50 Mm Thickness After Stamp The Surface By Special Concrete Stamping Mould As Per Specified Texture And Colour Etc. Next Day Apply Finish Coat Of Kelmer A60 Of Dimple Chemical & Services Pvt. Ltd Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. ( Note- Gsb , Colour & Stamping Rates Not Included In This Ra ) , Masonry Bridge Repair Work:- Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For T-Pointing To A Depthupto 50 Mm Or As Per Surface Conditions And Raised On Stone Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Manual Or Mechanical Means. After That, Clean The Joints With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removing Of Algae Fungi Followed By High Pressure Water Jet And Compressed Air Blower. Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404 Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Top Coat Will Be Done With Kelmer A 60 + Niccoat Pc On Picc To Seal The Surface And Reduce The Porosity Etc Complete As Per Specification Including Cost Of All Material, Machinery, Labour, Scaffolding, Transportation Etc. With All Leads And Lifts As Directed By The Engineer-In-Charge. , Providing & Grouting By Polyceramic Cementitious Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicgrout G 06 + 53 Grade Cement + Water As Per Requirementto Reduce The Porosityof Concrete / Masonry Structure And To Increase The Strength Of Structure Usinggrouting Pipes, Grouting M / C, Mixer Etc And All Relevant Safety With All Leads And Lifts, Material, Machinery, Labour, Scaffolding Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Removal Of Vegetation / Plants:- Removal Of Vegetation & Plants By Its Roots From The Entire Surface Of Bridge With Manual Or Mechanical Means. After Removal Of Vegetation & Plants, Roots Shall Be Treated With Special Chemical I.E. Steripure Mbt 20 Of Dimple Chemicals & Services Pvt. Ltd. Top 50 Mm Shall Filled With High Strength Grout ( Nicgrout G 06Ofdimple Chemicals & Services Pvt. Ltd+ Cement 53 Grade ) Including Cost Of All Material, Machinery, Labour, Scaffolding, Etc.As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wris An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm In A Ratio Of 1:1 ( Picc Mortar1 Part: Metal 6Mm 1Part ) Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 In To Above Morter For Normal Setting Of Dimple Chemicals & Services Pvt. Ltd. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applying Impermeable, High Compressive Strength, Monolithic Application, Excellent Bond Strength, Anti-Skid, High Abrasion Resistance, Uv Resistance, Self-Curing, Non-Toxic Polymer Based Cementitious Mortar Named Aspoly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Filling Potholes For Concrete & Bitumen Roads To A Thickness Upto 75 Mm Or As Per Surface Conditions And Also Treatment Of Honey Combing Areas Etc. Cleaning Will Be Done By Remove All Loose Particles, Dust Particles Or Any Other Foreign Material / Particles Using Breaker, Wire Brush, High Pressure Water Jet, Compressed Air Jet ( Manual Or Mechanical Means ) . Applybond Coat A Water Miscible Epoxy Named As Kelox R 101 + Kelox H 404Of Dimple Chemicals & Services Pvt. Ltd. ( Using Manual / Mechanical Means ) Before Picc Application, It Ensure Strong Adhesion With Old Surface To New Picc Mortar. Add Nikure 500 Of Dimple Chemicals & Services Pvt. Ltd. On Above Mortar Picc Will Be Ready To Traffic Load After 1 Hr Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing And Applying 30 Mm Thick Self Curing Ceramic Polymer Microconcrete Of Dimple Chemicals & Services Pvt. Ltd. Having Compressive Strength Above M30, Non Shrink, Impermeable, Filling Mortar In Cavities Like Beams, Column Etc. To Load Carrying R.C.C Member In One Or Two Layers ( Depending Upon The Site Condition ) On Cleaned Concrete Surface , Includinghoney Comb Area ( Using Manual / Mechanical Means ) . Mixingmortar Of Nicocil C80 And Fresh 53 Grade Cement With Required Water Cement Ratio For Desired Consistency And Applying And Finishing By Manual Trowelling , Curing After Curing Initial Setting Time Etc, As Per Manufacturers Specification Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Kelox R 101 ( Resin ) + Kelox H 404 ( Hardener ) A Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. For Bonding Old Concrete To New Picc Mortar, After Mixing Slowly In Predefined Ratio And Applying By Brush On The Surface. When It Is Tacky Then Apply The Picc Mortar Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coat Is Done Which Is Named As Duraguard A 3 Pack System Of Dimple Chemicals & Services Pvt. Ltd., This Is A Blend Of Water Miscible Epoxy Andgives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance Etc. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. After 2 To 3 Hrs Of Wrapping Apply Final Coat Of Duraguard When Surface Is Tacky. This Coats Will Give The Thickness Approx. 350 Micron, As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) . After Primer Application Base Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System, Kelox Rb5050 & Kelox Rh4040 This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Wrapping Will Be Done With Duramesh Of Dimple Chemicals & Services Pvt. Ltd. Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As Abrasion & Impact Resistance Followed By Top Coat With Bituminous Epoxy. This Coating Gives Better Performance As Compare To Coatings Specified In Is 10221 . Apply 2 Coats With A Thickness 1Mm ( Bituminous Epoxy + Duramesh+ Bituminous Epoxy ) As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness 40 Micron On Prepared Metal Surface. Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) After Primer Application Final Coating Is Done Which Is Named As Bituminous Epoxy Of Dimple Chemicals & Services Pvt. Ltd. A 2 Pack System Kelox Rb 5050 Kelox Rh 4040, This Is A Blend Of Rapid Setting Bitumen Emulsion And Water Miscible Epoxy I.E. Modified Epoxy Resin And Special Hardener. Apply 2 Coats With A Thickness Of 300 Micron On Prepared Metal Surface Etc. It Gives Properties Like Ant Rodent, High Corrosion Resistance, Chemical Resistance As Well As High Abrasion & Impact Resistance, Corrosion Protection Etc. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Providing & Applyingduraclean- Wr Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By High Pressure Waterjet Cleaning / Grinding, Wire Brush, Washing Or Mopping Also Removing Loose Particles ( Using Other Mechanical / Manual Means ) . Measure The Burr On The Surface By Burr Measuring Gauge, If The Burr Is Above 25 Microns Repeat The Cleaning Till Burr Is Below 25 Microns. Apply Duracap Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique One-Pack Cold Metalizing Process Consisting Of Blend Of Active Ceramic, Alumina And Modified Polymer. Duracap Forms A Dot Matrix Coating On The Surface, Which Gives Better Adhesion With Substrates. Apply 2 Coats With A Thickness Upto 40 Micron On Prepared Metal Surface . Duracap Ensures Good Corrosion Resistance, Its A Weldable Primer Also Work As A Uv Reflector Etc. Also Reduces Frictional Resistance To Flow Of Water. As Per Manufacturers Specification ( Using Other Manual / Mechanical Means ) Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Chargesas Directed By The Engineer In Charge. , Water Proofing Of Swimming Pool -- Providing And Applying Impermeable, Monolithic Application, Uv Resistant, Self Curing, Non Toxic, High Compressive Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Which Consists Of Nicomix Series + 53 Grade Cement + Water Of Dimple Chemicals & Services Pvt. Ltd.For Resurfacing The Concrete Surfaces Of Swimming Pool To A Thickness Upto 10 Mm Or As Per Surface Condition And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. By Removing Loose Material, Dust Particles, Grout Slurry By Breaking It With Manual / Mechanical Means. Removing Of Existing Embedded M.S. Bar If Any, Cleaning The Lift Joints, Honey Combing Areas And Entire Surface With Special Chemical Named As Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Removal Of Algae - Fungi Followed With High Pressure Water Jet. Apply Bond Coat Named As Kelox R 101 + Kelox H 404Which Is Water Miscible Epoxy Of Dimple Chemicals & Services Pvt. Ltd. Before Picc Application For Suitable Bond Between Old Surface To New Picc Mortar And Then Do The Picc Application Providing With Top Coat Of Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd. After Finishing, Complete As Per Specification Including Materials, Machinery, Labour , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Durabond Of Dimple Chemicals & Services Pvt. Ltd. Is A Unique Blend Of Organic And Inorganic Materials Consisting Ceramic Ironite, Active Ceramic, Cement And Water Miscible Modified Epoxy. As This Contain Water Miscible Epoxy, Can Be Applied On Wet Surface With Better Bond Strength Between Old Concrete And Waterproofing Coating Material For External Surface Of Building. Crack Filling Will Be Done By Duraguardof Dimple Chemicals & Services Pvt. Ltd, Having Cold Weldling Properties Which Cn Stick Anything To Anything. Surface Cleaning Is Done To Remove Loose Material, Dust Particles By Breaking Using Manual And / Or Mechanical Means, Cleaning The Cracks, Small Potholes And Surface Preparation Will Be Done With Special Chemical Name Steripure 10Of Dimple Chemicals & Services Pvt. Ltd For Algae- Fungi Removal And Then Clean It With High Pressure Water Jet, Then Applying A Durabond Of 2 Coats A Special Type Of Coat Suitable To Bond Old To New Concrete Finishing, Complete As Per Specification Including Materials, Machinery, Labour, Scaffolding , Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Duraclean Od Of Dimple Chemicals & Services Pvt. Ltd. Is An Organic Polymer For Emulsification & Dispersion Of Oil And Grease Spilled On Any Surface ( Concrete, Metal Or Water ) .Apply By Brush Or Spray On The Surface To Be Cleaned, Wait For About 5 – 10 Minutes, Wash The Surface With High Water Presure Jet.Repeat Process For Heavy Spillage And Surfaces Soaked In Oil Till It Is De-Oiled. Wait For 24 Hrs And See Whether The Penetrated Oil Comes Out To The Outer Surface, If Yes Then Repeat The Step 2-4. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Water Proofing Of Water Tank -- Providing And Applying Impermeable, Uv Resistant, Self Curing, Non Toxic, High Strength, Non Shrink, Polymer Based Cementitious Waterproofing Mortar Named As Poly Ironite Ceramic Cementitious ( Picc ) Of Dimple Chemicals & Services Pvt. Ltd. Which Consists Of Nicomix Series + 53 Grade Cement + Water For Resurfacing Of Concrete Surfaces Of Water Tank To A Thickness Upto 5 Mm Or As Per Surface Conditions And Also Treatment Of Lift Joints And Honey Combing Areas, Potholes Etc. Is To Be Done With Picc By Removing Loose Material, Dust Particles, By Breaking Using Manual And / Or Mechanical Means, Removing Of Existing Embedded M.S. Bar If Any, Cleaning Of Lift Joints, Honey Combing Areas And Surface Is To Be Done Using Special Chemical Named Steripure 10 Of Dimple Chemicals & Services Pvt. Ltd. For Algae- Fungi Removal Followed By Compressed Water Jet. Apply Primer Coat Name Kelox R 101 + Kelox H 404 A Water Miscible Epoxy Of Dimple Chemicals And Services Pvt. Ltd. Before Picc Application. Kelox Is A Bonding Agent Between Old To New Concrete Mortar. Top Coat Will Be Done With Niccoat Pc + Kelmer A 60 Of Dimple Chemicals & Services Pvt. Ltd., Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Impermeable, Anti-Wear Coating On Concrete & Bitumen Road :- Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. Having High Abrasion Resistant, Anti-Skid, Impermeable, Non Shrink, High Compressive Strength, For Concrete And Bitumen Road Coating Etc. Including Cleaning Of Concrete / Bitumen Road Surface By Wire Brush, Water Jet, Air Blower Etc. ( Using Other Mechanical / Manual Means ) To Remove Existing Loose Particles, Dirt Etc. Then Do Bituminous Coating By Taking Kelox Rb 5050 Of Dimple Chemicals & Services Pvt. Ltd.In A Clean Container & Add Kelox Rh 4040 Of Dimple Chemicals & Services Pvt. Ltd.In It, Apply This Mixture By Wiper On The Cleaned Surface.Top Coat Is Done Using Ready To Use Product I.E. Nicomix Butacoat Of Dimple Chemicals & Services Pvt. Ltd. , After Bituminous Epoxy Coating Immediately Sprinkle Nicomix Butacoat On Bituminous Epoxy Coating To Provide Impermeable, Antiwear & Antiskid Surface. After 10-15 Min, Use Roller On Top Coat I.E. On Nicomix Butacoatfor Compaction. After 6 Hours, Coated Surface Is Ready To Take The Load Of Traffic Movement, Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing And Applying Bituminous Epoxy Coating Of Dimple Chemicals & Services Pvt. Ltd. An Impermeable, Excellent Bonding With Old Surface, Non Shrink Repair Coating For Concrete Terrace & Etp Plants Includs & Steel Structurebituminous Coating By Taking Kelox Rb 5050 In A Clean Container & Add Kelox Rh 4040 In It, Stirr Well To Get Homogeneous Mixture, Apply This Mixture By Brush Type Wiper On The Cleaned Surface I, E Dust And Loose Partical Free, No Algae Fungi, Non Oily Surface, Corrosion Free Etc. Bituminious Epoxy Coating Is A Two Pack System Consist Of Kelox Rb 5050 Is A Blend Of Bitumen Emulsion With Epoxy Resin And Kelox H 404 Is A Modified Hardener.It Ensures Strong Adhesion With Any Substrate Like Concrete Road, Bituminous Road, Metal, Wood Etc. Complete With All Leads And Lifts, Material, Machinery, Labour Etc. Complete As Per Specification And As Directed By Engineer-In-Charge. , Providing& Applyinghigh Abrasive Resistant, Impermeable , High Strength, Non Shrink, Self Curing Poly Ironite Ceramic Cementatious ( Picc ) Of Dimple Chemical Services And Pvt Ltd, Which Consists Of Nicomix Series + 53 Grade Cement + Water I, E Piccmortar Mixing With Water Misible Epoxy I.E Kellox R 101 + Kelox H 404 Of Dimple Chemical Services And Pvt Ltdin The Ratio Of 80:20 ( Picc:Epoxy ) And Fill Thecracksfor 10 Mm Width & 10 Mm Depth With 1 Rmt Lengthon The Concrete Surface Ofroad, Industrial Floor Etc, Including Cleaning Of Cracks ( Using Manual / Mechanical Means ) , Power Tool Cleaning, Clean With Special Chemical Steripure 10 Of Dimple Chemical Services And Pvt Ltd For Alge Fungi Removal & Duraclean Od Of Dimple Chemical Services And Pvt Ltd For Oil Removalwith High Pressure Water Jet, Apply Bond Coat Of Water Misible Epoxy Of Keloxbefore Picc:Epoxy Application And Finishing, Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts And Any Other Incidental Charges As Directed By The Engineer In Charge. ( As Per Data Rate ) , Providing And Applying Duraclean Wr Of Dimple Chemicals & Services Pvt. Ltd. An Organic Polymer For Conversion Of Unwanted Substrate ( Burr ) On Metal Surface Crystal Structure Modification To Remove Oxide By Washing Or Mopping. Mesure Burr On The Surface, Spray Duraclean Wr On Surface To Be Cleaned, Wait For 5-10 Min And Then Wash It Off With High Pressure Water Jet. Again Mesure Burr On The Surface, Repeat The Process Till Burr Is Below 25 Micron Or 10% Of The Orignal Burr. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Applying Clonon Of Dimple Chemicals & Services Pvt. Ltd. Clonon Is A Revolutionary Product Forbroad Spectrum Odour Remover.Clonon Contains A Proprietary Combination With Major Ingredilents Like Active Lodophor Solution, Benzalkonium Chloride Glutaraldhyde And Others, Clonon Product Main Features Of Odour Remover, No Added Fragrance , Debonds Nano Particles From Surface, Bacteria Killer, Quik Action, Non Toxic Chemicals, Ready To Use, No Stain And Residue , Does Not Contain Formaldehyde, Biodegradable Environmental Friendly.Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge , Providing And Laying In Situ Cement Concrete M -30 With Tremix Treatment For 200 Mm Thickness For Concrete Road With Uniform Sprinklingthe Nicocil R 90 Of Dimple Chemicals & Services Pvt. Ltd Using Travelfor Surface Hardening , High Abrasion Resistance And Low Porosity.Also Is Includinglaying Plastic Sheet For 125 Micron Thickness With Groove Cutting Of 4 Mm Wide And 20 Mm Deep With Necessary Refilling With Polysulphidesealant ( Pouring Grade ) Confirming To Bs : 5212 - 1989 Into Sawed Groove Widened At Top For Sealant Reservoir Of Specified Size And Shape As Per Detailed Drawing Including Fixing Polyethylene Foam Backer Rod Of Required Diameter ( Excluding Reinforcement ) With Coarsen And Fine Aggregate Using V.S.I.Qualityartificial Sand Etc. Complete As Per Specification Including Cost Of All Materials, Machinery, Labour, Insurance Charges As Directed By The Engineer In Charge. ( Note- Construction Of Concrete Road As Per Instruction Of Engineer-In-Charge Or Requirement, Rate Of Construction Not Included ) , Providing And Applying Steripure S 30 Of Dimple Chemicals & Services Pvt. Ltd. Is Antibacterial, Antifungal Water Base Solution To Remove Algae-Fungi From Concrete , Masonry , Metal, Stone, Tile , Wood, Paver Block And All Composite Material Surface. Spray Steripure S 30 ( Prepar Dillusion In 1 Part Steripuri S30 : 9 Part Water ) On Surface To Be Cleaned, Wait For 15 - 20 Mins Then Wash The Surface With High Pressure Water Jet. This Unique Product Kills The Roots Of Algae-Fungi Which Can Be Removed From Surface By High Pressure Water Jet Cleaning. Re-Growth Of Algae-Fungi Is Stopped Due To Removal Of Roots. Complete As Per Specification Including Materials, Machinery, Labour, Insurance Charges Transportation With All Leads And Lifts As Directed By The Engineer In Charge. , Providing And Laying Of Rumble Strip Usingplastirib 2K 2 Component Cold Plastic Road Marking Material In Single Monolithic Application To Create Rumble Strip Raised Section 15 Mm - 20 Mm High , 200 To 300 Mm Wide And Spaced About 1 Meter Centre To Centre Of Roughly 6 Numbers At One Location, Across The Entire Carriageway. Each Rumble Marking Shall Be Made Complete With Drop On Solid Plus Reflective Glass Beads @ 350 Gm / Sqm Spread Throughout The Surface Of Marking. The Finished Surface Shall Be Levelled, Uniform , Free From Straks And Holes Including Surface Cleaning And Cost Of All Materials Etc. Complete. As Per Irc 99, These Rumble Strips Shall Be Applied As Traffic Calming Measure. , Kerb Stone / Vertical Surface Painting With Reflective Paint, Make Grade 1 ( As Per Is 164 ) Water Based Acrylic Paint, Preferably Mechnical Application For One Coat Priming Coat And 1 Uniform Retro Reflective Finish Coat In Required Colour. Yellow Retroreflecive Coat Shall Be Bright Yellow During Night With Minimum Rl ( Dry ) > 375 Mcd / M2 / Lux White Retroreflective Coat Shall Be Bright White During Night With Minium Rl ( Dry ) > 450 Mcd / M2 / Lux .Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Providing And Applying 2 Component Cold Plastic Night Glow Paint Rolled On Surfacing Material Solvent Free, High Build Two Pack Seamless, Tough, Skid Resistant, Material Which Has Property Of Attaining 600 Microns Thickness In Single Coat Application White ( Or As Required Colour ) Based On Glass And Colour Retaining Acralic Cross Linking Resin System For Coloured Road Surfacing Including Surface Cleaning And Cost Of All Material Etc. Complete. ( All Inclusive On Bitumen Or Concrete Surface ) Night Glow Paint Shall Preferably Be Roller Applied. After Glow Finish Surface Shall Provide Minimum Of 8 Hrs Glow After Fully Absorbing Ambient Light ( Visibile Light Or Uv Light ) For 15 - 30 Min. Cleaning Of The Surface Thoroughly By Removing Flakes, Dust Deposits, Vegetation Growth, Pasted Paper Etc., Using Coir / Coil Brush, So As To Enable The Application Of Respective Primer Etc. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On - Bituminous Surface Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Augmented Wet Reflective Dot ( Awrd ) Marking System On Awrd On- Concrete Surface With Application Of Special 2 Component Cold Plastic Road Marking Primer Supply And Application Awrd Road Marking System With Minimum Of 50% Of The Intended Road Marking The Surface Area To Be Covered With Dots Of Thickness Of 5+1 Mm, Each Dot Having Dia. Of 25 + 5 Mm Using Plastidot 2K 2 Component Cold Plastic Road Marking Material And Solid Plus 100 Drop Of Glass Beads With Ri 1.6. Performance Parameters Shall Comply With Rl Dry > 800 Mcd / Sqm / Lux & Rl Wet > 250 Mcd / Sqm / Lux , Measured Using Zehntner Gmbh / Esylux / Delta Make Reflectometer In Case Of Concrete / Worn Out Bituminous Surfaces Application Of 2 Component Cold Plastic Road Marking Primer Is Mandatory. , Supplying And Fixing Of High Performance Moulded Shank Raised Pavement Marker / Cats Eye Made Of Reinforced Polycarbonate And Weather Protected Ip > 68 Abs Moulded Body Having 2 Compartment Scratch And Abrasion-Proof Prismatic Polycarbonate Lens Capable Of Providing A Total Internal Reflection Of The Light Entering The Lens Face And Shall Support A Load Per Wheel ( Per Axle ) Of 20000 Kg And Per Axle 40000 Kg Tested In Accordance To Astm 4280D & En 1463-1 And En 1463-2 And Morth. The Dimensions Of The Pavement Marker Being 100 X 100 X 18 Mm And Weight 140Gm, Pin 55 Mm Depth Dia 13 Mm In Star Shape For Better Gripfixing Will Be By Drilling Holes On The Road For The Shank To Go Inside, Without Nails And Using Cold Plastic-Based Adhesive As Per Manufacturers Recommendation And Complete As Directed By The Engineer. The Contractor And Manufacturer Shall Submit A Minimum 1 Yr Installation Warranty And 2 Years Reflectivity Warranty For Satisfactory Field Performance. , Supplying And Fixing Of Solar Road Studs ( High Performance ) Polycarbonate Body, Pavement Surface Mounted Compliant Withen1463 Part 3 Havinguni-Direction Or Bi-Directional With Solar Powered Led Illumination And Reflective Panel Having 1 ) Dimensions 115 X 100 X 8.5 Mm 2 ) Marker Shall Support A Load Of 20 Ton Tested In Accordance To En 1463 . 3 ) Waterproof And Dust Protection Ip > 68 4 ) Weight 117 Gram 5 ) Fixing Using 2 Coponent Cold Plastic Based Adhesive / Butyl Tape Or As Reccomended By Manufacturer 6 ) Working Temperature: Up To 80 Deg. C 7 ) The Contractor And Manufacturer Shall Submit A Technical Warraty Of 1 Yr. , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture And With Approved Stencil Pattern Following By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing Concrete Resurfacing System Of High Strength High Abrasion Resistant Deck Crs Base Coat And Deck Crs Top Coat Of Approved Color With Antiskid / Rough Texture Without Any Pattern ( Plain ) And Followed By Deck Sealer Final Coat, Including Providing Surface Preparation By Using Grinder Machine / Hand Grinders On Serrated / Slurried Concrete Surface To Expose Original Hard Concrete Surface And Washing Area Thoroughly Including Removal Of Nails Erc Complete. Surface Will Be Open To Traffic After 72 Hours Of Application Of Deck Crs. Deck Crs Consumption 3.8-4 Kg / Sqm , Providing And Fixing 50 Mm Thick Door Shutter Using 25 Block Board 10 Mm Ply On Either Side Of Block Board , 4 Mm Thick Veneer On One Side With Melamine Polish And 1 Mm Thick Laminate On Other Side , Ss Hinges ( Brass ) 125 Mm , Tower Bolt 380 Mm , Mortise Lock , Concealed Door Closer Including Necessary Teak Wood Bedding , Fevical , Screw & Labour For Fixing Etc Complete As Directed By Engineer In Charge , Providing And Fixing 50 Mm Thick Main Entrance Door Partly Panelled And Partly Glazed Door Using 25 Mm Block Board , 10 Mm Ply Garjan On Either Side , Teak Wood Beading Covered With On Side 4 Mm Thick Rich Veneer With Melamine Polish, Floor Spring , Concealed Lock , 1.2 M Handle Pair Of 25 Mm Dia , Glass Pannels Of 0.40 X 0.40 Including Necessary Fevicol , Nails Screw And Labour For Fixing Etc Complete , Providing And Fixing High Quality Inter Locking Concrete Cobble Stone Finish Pavers In Circular Form Having Area Of 1.218 Sqm ( Approximately 71 Or 74 Nos. In One Circle ) , Made By Using Rubber Moulds Of 60 Mm Thickness, Tested And Certified By Csir-Cbri Of Having Strength Of 500 Kg / Sqm. Pavers Should Have 10 Mm Face Layer In White Cement With Pigment Of Lanxess Or Tata Make And Base Mix In M40 Grade Concrete. The Pavers Should Be Made Available In Various Sizes To Make A Circle Of Approved Finish And Design Of Standard Make On A Bed Of Crushed Sand Of 25 To 30 Mm Thick Including Skirting Joints And Cleaning As Directed By Engineer Incharge Etc. Complete. Prior Approval Of Superintending Engineer Will Be Necessary . , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size600 Mm X 450 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 600 Mm X 450 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Light Duty Withstand To Carry A Load Of 5.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Medium Duty Withstand To Carry A Load Of 12.50 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Fiber Reinforced Cover To Inspection Chamber With Frame Of Fibrocast Or Equivalent Make Of Size 900 X 600 Mm Heavy Duty Withstand To Carry A Load Of 25.00 M.T. With 2 Years Warranty Issued From Company, Also Should Submit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge. , Providing And Fixing Glass Bricks Of Size 190 Mm X 190 Mm X 80 Mm Fitted Inside Already Prepared Ss / Ms Fabrication Using Silicon Glass Sealant Before Placing Of Bricks And After Placing Of Bricks To Create A Bond Between Fabrication Material And Glass Bricks, Finishing The Surface By Filling The Gap Between Glass Bricks With White Cement Etc. Including Loading And Unloading Of The Material As Directed By Engineer In Charge. , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.65M*0.35 ) . , Supply, Providing Manufacturing And Fixing Of Interchangeble Plates Of Assigned Designation Post And Room Of Office, Judges And Subordinate Of Organization Of Providing 5 Mm Blue Frp Sheet For Base Surface And 5 Mm Frp Sheet Laser Cutting Latter Of White Color With Measuring , Marking, Cutting, Finishing Also With Fixing Of Letter On Based Surface By A Solvent By Providing Latters Name In Required Language Style, Type Font Including Interchangeble System For Easily Changing Of Plates As Per The Requirement For Pleasent And Elegant Look With Screw And Grip As Per Requirement And Direction Etc Complete. ( Size-0.25M*0.35 ) . , Providing & Fixing Ester Resin Material 5Th Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflective Sheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 1St Km Structure As Per Irc-08-1980 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessories Front & Back Side Bonded With Type Iv Retro Reflectivesheeting & Lettering Etc Complete. The Contractor Has To Provide Outerdoor Test Certificate Of Type Iv Reflective Sheeting From The Retro Reflective Manufacture. For Fixing Structure Excavation Of 0.75 X 0.75 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Providing & Fixing Ester Resin Material 200 Mtr Structure As Per Irc-26-1967 With Chopped Strand Mat 350 Micron Gsm With H2o2, Cobolt Octate ( 3% ) , With Pigment & All Required Allied Accessoriesfor Fixing Structure Excavation Of 0.60 X 0.60 X 0.45 Mtr. & Filling The Soil Inside The Bags & That Bags Filled In The Structure As Directed Engineer In-Charge Etc Complete , Milling Of Bituminous Pavement Upto Depth Of 50 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead Charges Of 10 Km As Directed By Engineer In Charge , Milling Of Bituminous Pavement Upto Depth Of 100 Mm By Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Dismantling Of Rigid Concrete Pavement Upto Depth Of 50 Mm Using Cold Milling Machine Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Re-Texturing Of Rigid Concrete Pavement Upto Depth Of 20 Mm Using Cold Milling Machine With Fine Milling Drum Of Width 1.5M Or Above Including All Levelling And Slope Sensors, Self-Loading Of Milled Material By Discharge Conveyor Onto Transport Vehicle Including Lead 10 Km As Directed By Engineer In Charge , Providing And Fixing Stainless Steel ( Grade 304 ) Made Of Hollow Tubes, Channels, Plates Etc., Including Welding, Grinding, Buffing, Polishing And Making Curvature ( Wherever Required ) And Fitting The Same With Necessary Stainlesssteel Nuts And Bolts Complete, I / C Fixing The Railling With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer-In-Charge, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixingh Accessories Such As Nuts, Bolts, Fasteners Etc. ) . , Providing Concrete Surfacing System With Deck Crs With Base Coat, Application Of Pattern In Stencil Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing Concrete Surfacing System With Deck Crs With Base Coat Followed By Top Coat And Sealer Including Surface Preparation Etc. Deck Crs Consumption About 4 Kg / Sqm As Per Manufacturers Specifications , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixing High Density Polypropylene Under Ground Water Tank Of Requiredsize With 5 Years Warranty Issued From Company, Also Shouldsubmit Test Report From Manufacturer Etc. Including All Labours, Accessories, Leads, Lifts And As Directed By Engineer In Charge ( From 1000 To 3000 Litre ) , Providing And Fixingchevron Sign Boards In Rectangular Size Of 500X600 Mm Made Out Of ___Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 3.45 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 500X600mmmade Out Of 3Mm Aluminium Composite Material With 0.25Mm Skin Thickness On Either Side , Providing And Fixing One Way Hazard Marker Sign Boards In Rectangular Size Of 300X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge. 300X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing Two Way Hazard Marker Sign Boards In Rectangular Size Of 450X900 Mm Made Out Of 4Mm Aluminium Sheet Bonded With White Retro Reflective Sheeting Of Class B ( Type Iv High Intensity Micro-Prismatic Grade Sheeting -Hip ) Having Pressure Sensitive / Heat Activated Adhesive Retro Reflective Specified Background, Border And Back Side Retro Reflective Symbols, Letters, Numerals, Arrow As Per Irc 67-2012 Supported With Back Support Frame 25Mmx25mmx3mm, Duly Painted On Back Side With Grey Stove Enamel Paint And Supported On One No. Of M.S. Angle Iron Post Of 65Mmx65mmx6mm, 1.8 Mtr Long, Dully Painted With Flat Oil Paint Having Alternate Black And White Bands Of 25Cm Width Including G.I.Fixtures Etc. Fixing The Boards In M25 Grade Concrete Block Of Size 60Cm X 60Cm X 75Cm Including Transportation Etc. Complete.Class-B ( Type Iv High Intensity Micro Prismatic Grade Sheeting -Hip ) Shall Have 7 Years Writen Warranty From The Manufacturer Of The Retro Reflective Sheeting And Authorised Distributor / Converter Issued For Fiedl Performance Including The Screen Printed Area And Cut-Out Sheeting And Cut-Out From The Durable Transparent Overlay Film And This Warranty Certificate In Original & A Certified Copy Of 3 Year Outdoor Exposure Test Report From Third Party Test Lab For The Product Offered Shall Be Submitted By Contractor To Engineer Incharge.450X900mmmade Out Of 4Mm Aluminium Composite Material With 0.5Mm Skin Thickness On Either Side , Providing And Fixing 8 Mm Tinted Tuffan Glass With Fitting Inaluminium Section Of Size 100 Mm X 763 Mm Also Including Door Glass With Ss Handle Of Size 1.2M Height And 50Mm O.D. And 30Mm I.D. And Ss Door Hinges Of Size 150Mm Height And 80Mm Width On One Face, Fitting Glass With Silicone Tube Including Scaffolding And Fitting Charges Etc. Complete & As Directed By Enginner Incharge , Encasement Of Columns And Beams By Placing 75 To 100 Mm Thick Free Flow High Strength Micro Concrete With Leak Proof Shuttering With All Equipments, Manpower Etc Complete , Providing And Applying Epoxy Mortar Epibond 11 In Areas Of Fixing Cracks, Charges For Repairing Of Full Depth Crack ( 30Mm Depth X 50Mm Width / Per Rmt ) On Pqc Pavement Using Cross Stitching Method As Per Specification Of Irc Sp : 83-2008. Making Chase Along Crack And Cleaning The Holes / Chase With Oil Free Compressed Air, Fixing Of Reinforcement In Holes Filled With Epoxy Resin In Enough Quantity For The Bar To Be Completely Coated When Inserted In The Hole, Chase Filling With Epoxy Epibond 11 ( 1:1:8 ) Resin+Hardner+Fine Sand As Per Manufacture Specification, Curing, Transportation, Required Machinery, Tool And Tackles Etc.Complete As Per Direction Of Eic. , Providing And Applying Volatile Corrosion Inhibiting Wax Powrthrow Ht Wax On Ht Lrpc Strands Before Embedment In Tendons, Lrpc Strands Of 12.7Mm & 15.2Mm , Tendon Duct Need To Be Lime Washed Prior To Insertion Of Lrpc Strands Coated With Wax. The Wax Must Be Hand Applied Using Gloves From The Pail Prior To Insertion On Strand In Duct. Powrthrow Ht Wax Is Bipolar In Nature Should Protect The Strand From Corrosion. As Per Jis Z 1535M Method Should Have Excellent Resistance To Corrosion Spots. And The Wax Should Show A Potential Change Of Minimum 120Mv As Per Corrosion Potential Test.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Maharashtra View Result →
13.
Rural Development #10780577 Price Bid
Tender For Concrete Bandhara At Washi Tarfe Devrukh-Boudhwadi Nearby Pwss Well Tal Sangmeshwar, Dist Ratnagiri - 1 Item No1:-Excavation in soil,soft murum, lime,shaduexceeding 1.50 m.in width including depositing the material as dieected with lead up to 15 m.and liftto 1.50 m. including. 2 Item No2:-Excavation in soft rock exceeding 1.50min widthincluding depositing the excavated naterial as directed with lead upto 15 m and lift upto 1.50m including dressing 3 Item No3:Excavation in hard rock exceeding 1.50m in width by blasting including depositing the excavated naterial as directed with lead upto 15 m and lift upto 1.50m includingdressing (This includes boulders of size more than 0.10 cum under other items) 4 Item No4:Providing and laying in situ cement concreteof grade M 15 ( Below 40 MSA ) of trap/ and bedding, compacting and curing, including Royalty of material etc. completestrength etc lifts including testing of concrete compressive with all leads and 5 Item No5:Providing & Cutting bending hooking laying in position and laying M S bars for reinforcement ofRCC work as per detailed drawing etc. complete. 6 Item No6:Constructing of embanking for Casing zone withselected material directly from borrow area including transporting the material with all leads and lifts laying in layers , watering and consolidation including royalty ofleveling ,spreading including material etc. complete.( Refilling gap of foundation ) 7 Item No7:Providing and fixing Road junction / Information sign board of size 1.20 m x 0.75 m. prepared on 16 gauge M.S. sheet with angle iron frame of size 35 x 35 x 3 mm with cross bracing of size 25 x 25 x 3 mm including painting with one coat of zinc cromate stoving primer and two coats each of green/white back ground and back side gray stove enamelled, bonded with red retro reflective sheet Engineering grade, border / letters / numeral / arrows, coated with non pealable crystal clear protective transperent coat retaining 100% reflection including two angle iron post of size 50 x 50 x 5 mm of 3.65 m. long inflated at bottom drilled on top and painted in white and black bands of 30 cm. with 4 Nos. high strength G.I. bolts and nuts of size 10 mm dia. and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement concrete 1:4:8 block of 60 cm x 60 cm x 75 cm size as directed by Engineer-in- charge etc. complete. Spec. 8 Item No8:-Straight Needle K.T. Weir Gate-Manufacturing- Manufacturing with QAP & fabrication of KT weir needle gates - straight type size 2.15 x 0.5M- 94 Kg. weight as per relevant Indian Standards with all material, Mild steel confirming to IS 2062, Rubber seal confirming to IS 4623 & Welding electrodes AWS E6013 for general weld joints. It includesall materials, Labour charges, machinery 1km lead charges of transportation, loading and unloading charges of Gate parts at Site, Inspection & Quality control charges, Sand blasting, Painting with one coat of Zinc rich primer on dry film to give total dry film thickness 70 +/- 5 microns and 2 coats of sloventless coal tar epoxy paint applied to give minimum dry film thickness of 150+/- 5 micronper coat per IS 14177. 9 Contengencies Rs 10 Add GST 18% 11 Add Labour Insurance 12 Add Royalty
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
14.
Drinking Water Supply and Sanitation #10772798 Price Bid
Tender For Rehabilitation Of Galwa Irrigation Sub Project. District Tonk - Side shuttering including propping etc. complete (to achieve finish F 2 for :Retaining wall, counterfort, abutment, wing walls up stream or down- stream slope facings of dams and open faces of construction joints etc. 2 Centering and shuttering for slabs, beams, lintels Columns, trough with or without caps and base including propping and remove 3 Supplying of M.S. reionforcement including labour charges for bending binding and placing in position all reinforcement as per drawing including cost of binding wire and all leads and lifts using. Tor or ribbed bars (IS :1786-1985) 4 Design, Drawing, fabrication, supply, erection, testingandcommissioningofVerticalliftsliding type gate with frame consisting of skin plate, sealingframe,stiffeners,horizontalandvertical girders,guide,stainlesssteel flat/Brass flat, rivets, wedges, lifting rodsetc., with all accessories as per relevant IS codeincluding frame & gatecomplete set for Canal Cross, Escape, Head regulator /Tank head regulator including cost of all materials, machinery,labour,cutting,aligning,welding, finishing,cleaning,sealfixing,toolsandtackles etc., applying two coat of zinc rich epoxy primer to give dry film thickness of 70 5 microns and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150 5 microns per coat thus total dry film thicknessofallcoats,includingprimercoating, should not be less than 350 microns., complete as per specificationsandapproved drawings with all leadand lifts,includingpacking&forwarding, transportation chargesforstructuralsteel components and other materials. 5 Providing, lowering, laying and jointing in trenches. standard lengths HDPE ISI marked Pipes as per IS-4984: l995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid. separately. Supply upto 110 mm dia. in coil & above 110 mm dia straight length in 6M. HDPE PE-100 PN-6 75 mm dia 6 Providing, lowering, laying and jointing in trenches. standard lengths HDPE ISI marked Pipes as per IS-4984: l995 (amended upto date) with necessary jointing material like mechanical connectors, i.e. thread/ insert joint/ quick release coupler joint/ compression fitting joint or flanged joint and specials jointing pipe by butt fusion/ electro fusion welding method, including all taxes , transportation and freight charges, inspection charges, loading/ unloading charges, stacking of pipes, including cost of labour and material, specials (Tee, bend etc.), satisfactory hydraulic testing, disinfection etc. complete as per technical specifications and direction of Engineer-in-charge of following class and diameter. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid. separately. Supply upto 110 mm dia. in coil & above 110 mm dia straight length in 6M. HDPE PE-100 PN-6 90 mm dia 7 Cutting & clearance of jungle, bushes, shrubs Ankra/Ipomoea, Juliflora typna etc. on canal and bunds in dry/moist/slushy conditions including disposal as per instructions of the Engineer-in-charge. Cost of wood has been deducted from rates and thus will be property of contractor after cutting. For dowels and outer slopes. 8 Providing and laying cement concrete coping in (1:2:4) with maximum size of crusher broken aggregate upto 20 mm including shuttering etc. with all leads of material complete in all respect in thickness of: 50 mm 9 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm NP3 10 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 150mm Labour Charges only 11 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 200mm NP3 12 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 200mm Labour Charges only 13 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 600mm NP3 14 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 600mm 15 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 900mm NP3 16 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 900mmLabour Charges only 17 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 1200mm NP3 18 Providing, laying and fixing in position RCC spun or hume pipe with collars (ISI 458-2003) in required size packed in gasket for hume or spun yarn & neatly finished with rich grout of cement mortar 1:3 perfectly air tight including testing of joints. 1200mm Labour Charges only 19 Fixing of Distance stone in 30x30x30 cm pit excavated in all type of strata and back filling with cement concrete (1:4:8) projected 10 cm above ground level well finished and properly cured. (Excluding cost of Distance stone) 20 Distance stone well dressed of required shape and size 60 cm x 23 cm x 7 cm with exposed faces chiesel dressed. 21 Painting with synthetic enamel paint of approved brand and manufacture togive an even shade : Two or more coats on new work 22 Providing and laying damp-proof course with cement concretee grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification . 75mm thick. 23 P & F 1st qualityVitrified Porcelain Polished tiles on floor, skirting and steps etc.in different sizes (thickness to be specified by manufactuer) with water absorption less than 0.08% and conforming to IS 15622 of approved make in all colour and shade,laid with 20 mm thick CM 1 : 4 including grounting the joints with white cement and matching pigment etc complete. size 600 mm X 600 mm 24 Providing and fixing M.S. sheet 1mm thicksingle leaf door shutter in angle iron frame 35x35x5mm suitabilly diagonally braced with 25x3mm flat iron above and below lock rail of size 50x5mm beading extra including all fittings, as per direction of Engg. incharge but excluding cost of chowkhats: including two coats of anit-corrosive red oxide primer paint 25 Providing and fixing steel glazed doors windows and ventilator shutters of standard rolled steel section (IS 1038-1983) joints mitred and welded with steel lugs 13x3mm, 10cm. long embedded in cement concretee block 15x10x10cm. of 1:3:6 (1cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws with fixing clips or with bolts and nuts as required including providing and fixing of plain glass panes 4mm thick with cooper glazing clips and special metal sash putty of approved make or metal beading with screws complete including priming coat of approval steel primer, excluding the cost of metal beading and other fitting except necessary hinges of pivots steel handles peg stay etc. as required : Windows side hung /Ventilators top or centre hung (openable) 26 Providing and fixing Square bars or other flat welded to window, ventilatiors etc. 27 P. & F Squatting Pan (Indian type) white glazed vitreous china 1st quality W.C. Pan (IS : 2556 Mark) with 100 mm vitreous china P or S trap including cutting and making good the wall and floor (excluding the pair of foot rest.)Size 510 mm 28 P & F Low level Flushing Cistern of 10 litres capacity (IS : 2556 mark) of approved make with complete fittings C.I. brackets duly painted, brass ball cock with ball (IS: 1703 mark) complete including cutting and making good the wall: PVC with PVCbend as per IS : 7231 . 29 P & F WVC Wash basin (Ist quality IS:2556 Mark) of approved make with C.I. brackets duly painted 1 No. 15 mm C.P. Pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, P.V.C Waste pipe with PVC nut 32 mm complete including cutting & making good the wall : Size 510 mm x 400 mm 30 P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : Gun-metal 15mm nominal bore. 31 P & F G.I. Pipes (External Work) with G.I. fittings excluding union (IS : 1239 Mark) including trenching & refilling earth etc. 15mm dia nominal bore A Class 32 P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000 litres capacity. 33 Supply & fixing G.I. Union ISI marked in G.I. pipe line as required complete in all respect of size : 15mm dia nominal bore 34 P & F Bib Cock (IS : 8931 Mark), Superior quality of approved make: Brass 400 gm,15mm nominal bore. 35 P & F Stop Cock(IS :8931 Mark),superior quality & ofapproved make: Brass 400 gm. 15mm nominal bore. 36 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 75 mm dia 37 P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2.) approved quality /makeincluding joining the pipe with solvent cement rubber ring and lubricant. 110 mm dia 38 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Socket plug 110mm dia 39 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: W.C. connector bent type 110mm dia 40 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Reducer 110 X 75 mm 110mm dia 41 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Plain Tee 110mm dia 42 P&F rigid PVC pipe fittings (IS: 4985 mark) of approved quality /make including joining the pipe with solvent cement rubber ring and lubricant: Bend 87.5 110mm dia 43 Construction of Soakage well in all types of soil of approved drawing, top 90 Cm .Portion in 450mm thick masonry with CM 1:6, 80 mm thick stone slab covering,jointing of slab in CM 1:3 ,Ralthal, kharanja 40mm thick M-15 grade C.C flooring, earth worketc . complete including disposal of surplus earth within a lead of 50 mtr .Inner dia90 Cm & 10 to 12 Mtr deep. 44 Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil 45 Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard / dense soil Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). 46 Excavation including loading, unloading, disposal and dressing of excavated earth within initial lead of 50m and lift up to 1.5m including dressing of excavated area and dewatering wherever required complete in all respect Hard soil mixed with Kankar / boulders, Morrum Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). 47 Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m Deduct in item no 16 (a) to (d) above if Standard Proctor s density to be achived is at least 95 48 Earth work in rough (borrow area) excavation for embankments in hard soil, morrum or highly weathered strata dry or moist, including laying in20 cm layers (before compaction) and breaking of clods, sorting of grass, pebbles etc. and dressing when compacted by vibro compactor, vibro sheep foot roller, sheep foot roller/pneumatic tyred roller to obtain dry density of at least 98% of Standard Proctor s density with initial lift of 1.5m (Excluding charges for compaction and watering) including loading and un-loading wherever required complete in all respect.With initial lead of 250 m Deduct in item no 16 (a) to (d) above if Standard Proctor s density to be achived is at least 95 Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). Add extra over item 10 (a) for lead beyond 250m & upto 750m (for average 1/2Km). 49 (i) Compaction of earth or highly weathered strataBy mechanical equipment such as sheep foot roller/ pneumatic tyred roller/vibro compactor / vibro sheep foot compactor required as per site condition to obtain dry density of.at least 95% of Standard Proctor s density 50 Watering of earth including cost of carriage of water when source of water is up to 1 Km 51 Add extra for earth taken from private land with all lead and lift, land to be arrangged by contractor through private negotiations. Item applicable on certification by E.E. that no Government land is available with 250 meters from borrow area. 52 (i)Removal of slit/soil/earth, sand, pebbles,Malba , debris, rubbish, stone pebbles & obstruction deposited in canal bed up to design line grade and sections having design due to erosion/scour/slips in canal banks/silting with or without bushes and weeds etc. in dry or moist condition from canal bed including dewatering, loading unloading and disposal at suitable place as directed by Engineer in charge with initial lead of 50m. and lift upto 1.5 m with proper dressing on canal bed complete in all respect For depth above 15 cms but upto 30cms havingUnlined section 53 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Short point (up to 3 mtr.) 54 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - Medium point (up to 6 mtr.) 55 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure A attached with this BSR - On board 56 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories with own OEM CM/L No. as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR - 25 mm 57 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . -1200 mm Sweep BEE 2 Star rated (service value >=4.5 to < 5 ) 58 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. -9 Watt 59 Providing & Fixing of energy efficient /energy saving IP 20 LED direct retrofit Bulbin existing holder or fixture as required with system lumen efficacy ≥100 lm/Watt output ,pf 0.95 , CRI >70,minimum life time of minimum25000 Burning Hours with , 70% of intial Lumen maintaned till life ends, CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing onhousing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . for additional technical parameters of product/ work, refer Annexure A attacheded with this BSR. -18/20 Watt 60 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 2 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR - 2 x 2.5 sq. mm. + 1x1.5sqmm 61 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Single pole MCB (With B/C curve tripping Characteristics) - 6 A to 32 A rating 62 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR Metal door (single phase) IK-09 and IP-43 with Metal end box - 4 Way (4+2) 63 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR Double pole isolator - 63 A rating 64 Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:6 65 Random rubble stone masonry (using R. R. stones where 75 % stones to be not less than 15 cm in size in any direction and weighing not less than 23 kg.) for foundation including curing with all leads of all construction materials including curing etc. complete. In cement sand mortar 1:6 Masonry work in superstructure 66 Brick masonry (using well burnt clay bricks of size 230x 110x 70 mm, class designation 75 as per specification) up to plinth including all leads of all construction materials including curing etc. complete.In cement sand mortar 1:6 Add extra for superstructure brick masonry on item no 10 67 Plaster in cement sand mortar 1:4 including racking of joints, smooth finishing & curing etc. complete including all leads of all construction materialsof thickness:20 mm 68 Nominal mix of Plain Cement Concrete well mixed and laid in position using 20% max permissible limit of plums above 160 mm and up to 450mm, including curing and finishing etc including all leads of all construction materials complete in all respect with well graded crusher broken stone aggregate. The plums shall be distributed evenly and shall be not closer than 150 mm from the surface. PCC Nominal Mix 1:3:6 with Plum Max size of Aggregate 80 mm, 69 Preparation and dressing the sub grade including removal ofirregularities up to 7.5 cm in soil, morrum mixed with pebbles, small boulders and kankar & murrum forBed 70 Preparation and dressing the sub grade including removal ofirregularities up to 7.5 cm in soil, morrum mixed with pebbles, small boulders and kankar & murrum forSide slopes 71 Providing and laying cast in situ plain cement concrete design mix M-15 grade for lining, using well graded crusher broken aggregate of maximum nominal size 20 mm conforming to IS:383-1970, including proportioning of the ingredients by weigh batching and mixing by mechanical mixer including finishing of concrete lining, cutting of grooves for construction joints, complete as per specification with all leads and lifts of construction material complete for canal bed of thickness. 7.5 cm 72 Providing and laying canal lining with mechanically vibrated 300 x 150 x 50 mm PCC blocks made from concrete mix 1:2:4, A20 including all leads and lifts of material, curing, stacking, loading, unloading & transportation of blocks from manufacturing site to lining site. Single tilelining consisting of 12 mm thick cement mortar (1:6) plaster on sub-grade, 12 mm thick sandwich plaster in cement mortar (1:5) over sub grade & 50 mm thick tile lining in cement mortar (1:3) laid over 6 mm thick mortar layer in cement mortar (1:3) including curing,all leads of all construction materials, curing charges and machinery charges with mixture vibration etc., complete as per technicalspecifications.In sides 73 Brick masonry lining consisting of 12 mm thick plaster in cement mortar (1:6) on sub grade, 16 mm thick sandwich plaster in cement mortar (1:3) over base plaster & 70 mm thick brick masonry in cement mortar (1:3) laid over 6 mm thick mortar layer in cement mortar (1:3) including curing etc. including all leads of construction materials complete as per specifications. In bed 74 Brick masonry lining consisting of 12 mm thick plaster in cement mortar (1:6) on sub grade, 16 mm thick sandwich plaster in cement mortar (1:3) over base plaster & 70 mm thick brick masonry in cement mortar (1:3) laid over 6 mm thick mortar layer in cement mortar (1:3) including curing etc. including all leads of construction materials complete as per specifications. In sides 75 Filling of construction joints with Bitumen based sealing compound, including painting the concrete sleepers below lining and sides of lining panel as per specification provided in IS: 3384-1986 and all leads of all construction materials including cost of sealing compound, complete in all respect. 76 Providing and laying under drainage below canal lining consisting of porous concrete of mix ratio 1:4 (1 cement: 4 course aggregate) 75 mm diametre, 300 mm long supported by 75 mm thick layer of coarse aggregate 12.5 mm to 40 mm size and 50 mm thick layer of sand. 77 Providing and Laying in position of Cement concrete Nominal mix (1:1.5:3) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3(1 cement : 3 coarse sand) and making good the joints excludingthe cost of centering, shuttering and reinforcement. Well graded crusherbroken stone aggregate of maximum size upto; 20 mm 78 Providing and Laying in position of Cement concrete Nominal mix (1:3:6) including leads of all construction materials, curing, compaction and finishing with rendering in cement sand mortar 1:3(1 cement : 3 coarse sand) and making good the joints excludingthe cost of centering, shuttering and reinforcement. Well graded crusherbroken stone aggregate of maximum size upto 20 mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 5
Himachal Pradesh View Result →
16.
Metro Rail #10545528 Price Bid
tender for Maintenance Contract Of Civil Works Addition Alteration modification Repair Maintenance Of Various Stations Rss Buildings Between Mansarovar To Badi Chaupar And Any Other Metro Railway Premises Of Jaipur Metro Rail Corporation At Jaipur As Per Bid Documents - Maintenance Contract Of Civil Works : Addition, Alteration/Modification, Repair & Maintenance Of Various Stations & RSS Buildings Between Mansarovar To Badi Chaupar And any Other Metro Railway Premises Of Jaipur Metro Rail Corporation At Jaipur Sl. No. Item Description 1 6mm Toughened Glass in existing frame: Providing and Fixing 6mm thick clear float toughened glass in aluminium door, window, ventilator, shutters and partitions etc. with PVC/ Neoprene gasket etc complete as per architectural drawings and the directions of Engineer-In-Charge. 2 Providing and fixing in position Toughned glass of 12mm thickness all complete including minor cutouts/openings as per the direction of Engineer-in-charge. 3 Providing & Fixing of Floor Spring, Patch (Hydraulic) (OZONE MAKE) for Glass Door Assembly/Unit complete as per Directions of Engineer-In-Charge. 4 Providing and fixing tactiles 12mm thick yellow directional vitrified porcelain Granite tactiles (Australian made) laid on floor with laticrete 111 crete filler powder mixed with laticrete 73 latex admix and applied to a minimum thickness of 4.5 mm. The mixing ratio shall be as follows : 20 Kg Bag (Laticrete111):5.5 Ltr (Laticrete 73) spacer of 3 mm shall be used between the tiles and joints filled using laticrete Latapoxy SP-100 epoxy grout in Inca gold colour. The joint depth shall be 6 mm. Laticrete product shall be procured by Laticrete India Pvt Ltd/Laticrete International Inc (Tiles for blind people - directional tiles as installed in JMRC station) 5 Repair of defective rolling shutter with using any material required for bend repair,tightening of spring,bolt & screw and welding by welder as a complete job as per direction of Engineer In charge.(Upto 12 Sqm in area)(This item includes cost of necessary scaffolding,all lead & lift and consumable i.e welding electrodes of required specifications as per site requirements) 6 Extra For Reparing of Rolling Shutter having size more than 12 sqm in area 7 Skilled labour for sewerage chamber/pipe line cleaning/clearing choking with all T&P including all required machinery. 8 ROCA meridian-N soft close seat cover white 9 Providing ofaccess raised floor of light grade (15 KN/m2) UDL panels manufactured from pressed formed corrosion resistant galvanised steel with total overwrap of one piece top, sides and bottom flange encapsulating high performance chip board case stiched and with a panel to cater in the size 600*600*31mm with new panels of same specifications complete in all respects. the acess floor should be able to take a point load of 2.5 KN over 25 mm sq. and UDL of 15 KN/sqm. The panel shall be finished with high abrasion , anti-static HPL of formica colour Y606 having fire rating as per BS 476 clause 5, 6 & 7. 10 Supplying and fixing rolling shutters of approved make, made of 80 x 0.8mm color coated G.I Laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets of M.S, side guides of G.I and arrangements for inside and outside locking with push and pull operation complete including cost of sring hooks, providing and fixing necessary 45.0 cm. long wire springs grade No-02 including dismantling of existing rolling shutter as per the directions of Engineer-In-Charge. 11 Colour Coated G.I Top Cover 0.5mm thick for rolling shutters as per instructions of Engineer-In-Charge. 12 Providing and fixingpink dholpur sand stone work of size as specified below, of approved colour/patternat all levels for wall lining/Columns (veneer work) by mechanical arrangement with S.S.Cramp/ brackets,.Anchor bolts,5mm vertical S.S. of approved make. Inserts as per drawings and specifications. The cost for making necessary grooves in the stone to accommodate the vertical inserts, grooves all-around stone pieces, making 10mm deep rebate for tile inlay, chamfering of corner edges and polishing are included. 13 pink dholpur sand stonesize (1600-1800)x600x25mm minimum thick 14 Providing and laying 30mm thick FLAMED Sadarhalli Grey Granite Stone flooring in treads and landings (including bull nosing, rounding the nose and making groove) of stepsof approved colour, size and pattern, (sample of granite stone shall be approved by Engineer-in-charge) over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with neat cement slurry mixed with pigment to match the shade of granite stone complete as per specifications andas per direction of engineer-in-charge. 15 Extra for Red/ Raw Silk/ Tan Brown/ Jet Black granite Stone 16 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. 17 Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge. 18 Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Epoxy injection grout in concrete/RCC work of approved make. 19 Providing and applying crystalline mortar by mixing in the ratio of 4.5: 1 (4.5 parts crystalline mortar : 1 part water) for the treatment of faulty construction joints, cracks, tie rod holes and spalled & honeycombed surface of RCC underground structures like basement, water tanks, bridge deck etc. to ensure water tightness. The crystallie mortar shall conform to the EN 1504-3 having compressive strength Class R4 ?45 MPa and adhesive bond strength Class R3 ?1.5 MPa. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For sealing cracks and faulty construction joints, routed out/making U-shape groove size 25x25mm and then primed the area with integral crystalline slurry @0.05kg/ running metre and while the surface is tacky filled the groove upto surface with crystalline mortar @1.50kg/ running metre. Once crystalline mortar is touch dry then finally applied two coats of integral crystalline slurry @0.05kg/running metre per coat. 20 Strengthening of existing open cell metal false ceiling by clipping assembled cell ceiling panels into extra U-profile carriers (as per requirement) in Galvanized Mild steel, pre-coated in black enamelled finish. In addition to the carriers, extra C-profile wire clips shall be fixed to hold the cell ceiling panels into the carriers for strengthening. Further, for lateral strengthening,extra angles made out of Galvanized Mild steel shall be fixed for cross connection with U-profile carriers. Payment shall be made on the basis of unit plan area measured. This item includes all material, labour, night charges, scaffolding, transportation, taxes etc. 21 Providing and fixing 12 mm thick partition/doors assembly of solid acrylic material with stainless steel hardware complete in toilets. 22 Providing and fixing backlit or high quality flex prints of high resolutionimages and to be pasted or installed on the walls or any other surfaces,of approved size and design as directed by the Architect. Necessaryframework in wood or aluminium to be provided for mounting of flex panel asrequired or as directed by the Architect. Flex panel to be installed takingutmost care to avoid any damages or stains on walls etc. In case of theinstallation or printing is found unsatisfactory the sheet to be replaced withnew with necessary corrections as part of rectification works. Item to includeall necessary tools, Flex and printing, framework for mounting of flex panelscaffolding if required etc. complete 23 Providing and fixing Small Size MDF Bases for mounting Sculptures of required sizes and design as directed by the Architect. Base to be made using 19mm MDF sheets including necessary wooden framework if required and finished with Duco paint of approved shade and type as directed by the Architect. Item to include all necessary tools, hardware etc complete in all respects. 24 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : 25 Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 26 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 27 Providing and fixing 8mm thick Black Painted Toughened Glass Clading on walls of required size and design as directed by the Architect. 8mm thick Marine Plywood backing to be provided behind the glass, to be fixed over 25mm x 25mm teak wood framework fixed to wall @ 1.2M c/c or as required as per site conditions. Item to include providing necessary lipping to hold glass in place, tools, hardware etc. to complete item in all respects. 28 Manufacturing, supplying and Fixing retroreflective overhead signage boards made up of 2mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retroreflective sheeting confirming to type III of ASTM-D-4956-01 as approved by Engineer-In-Charge, letters, borders etc. as per IRC:67-2001 in silver white with blue color background and with high intensity grade, pasted on substraight by pressure sensitive adhesive backing which shall be activated by applying pressure confirming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts and nuts @ 300mm centre to centre all along the periphery as well as in 02 vertical rows along with theft resistantmeasures, including the cost of painting with two OR more coats of epoxy paint in grey color on the back side of aluminium sheet including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specifications and directions of the Engineer-In-Charge. (Structural Frame work Including M.S Plate to be provided seperately. Rectangular area of the sheet only shall be measured for payment). 29 ILLUMINATED SIGNS:Providing and fixing illuminated signs including all operations from fabrication to installation all complete as per relvant drawings, technical specifications, signage schedule and to the satisfaction of the Engineer-In-Charge. 30 SIGN FRAME:-The sign frame shall be made out of aluminium extruded sections fabricated to required sizes and shape. Item to include providing and fixing of aluminium channel spot welded to sign frame including channel supports are to be powder coated to match as per apptoved colour or in colour duly approved by Engineer-In-Charge. The inside edge of sign frame to have EPDM gasket where it gets in contact with the sign panel as per approved design is required.All powder coating shall be done on all internal as well as external surafaces. The Sign shall be internally lit with the specified luminare (LED MODULE) and item to include providing and fixing luminare and fixtures comple as per the technical specifications for electrical works. 31 SIGN PANEL:- For elevated and underground stations.Providing and fixing sign pannel made out of 04mm thick polycarboate sheeting with vinyl message (3630/7725 series 03M OR equivalent) to required sixe and shape. Vinyl colour to match graphics and text as per schedule and pasted on sign panel. All the confont in the signage will be plotter cut/screen printing. The signage will be laminated for the protection of plotter cut vinyl pasted on sign panel. For double side 32 REFLECTOR PANEL:- Item to include providing and fixing embosed aluminium mirror reflector panel as per approved specifications and make, with provision to hold luminaries in position. 33 BACK PANEL:- For elevated and underground stations.For single sided signs, where graphics/text is to be on 01 side. Item to include providing in embosed radiant mirror reflector, back panel to be pure polyster coated to match as per approved colour as per technical specifications.ACCESSORIES:- Providing and fixing all accessories such as magnetic catchers, hinges, spring clips, anchoring hooks, nuts, cleats, screw hooks and slots etc complete as per specified fabrication drawing. All anchor fastener, bolts etc to be SS-304 Grade.Above description holds good for the following signage unless otherwise specified except for modifications due to their respective finished dimensions and fixing arrangement OR unless otherwise specified. 34 ILLUMINATED FACE MOUNTED SIGN:- (At Height of Roof at Entry/Exit and at room height of Underground Metro Stations Badi Chaupar and Chhoti Chaupar)The sign frame is to be mounted on BRICK/RCC wall backing with cladded or Non cladded.Item to include aluminium sign frame of required size and shape including mounting the sign frame on the RCC/BRICK wall backing by drilling holes of required diameter in the RCC/Brick Wall and achoring the sign frame using HILTI FASTENERS or Equivalent or specified size and length and providing and fixing all item and accesaories including silicon sealant and backer rod of approved make complete as per drawing for following panel sizes. The mounting surfacesshall be required and finished as per surrounding area complete at no extra cost. This sign is to be necessarily signle sided only. All achor fasteners, bolts etc to be SS-304 Grade. (SIZE: 2400mmX900mm Approx. OR 5200mmX1000mm Approx. Depth of SIGN DEPTH: 75mm OR as approved by EIC) 35 Supply and Installation of Vinyl Sheet (03M) in UV Print on existing signages at metro stations of Jaipur Metro. 36 Providing and fixing 120 minutes steel fire rated doors as per detailed specifiction made by shakti mate, Godrej etc. Along with hinge and door closer as per nfpa 80 and as per NFPA 252, temperture increase on the unexposed surface not exceeding on average 361.c (650.F) during first 30 mins of test size as per directions of Engineer in charge. 37 Re-alignment of misaligned doors by taking out the door and the door frame (as per site requiement), rectifying and re-fixing of the same. The door shall be made good using any fixtures required (except hinges, door closer, trim paces, panic bars) and nithing shall be paid extra in line of the same. The work shall be carried out as per the direction of Engineeer in charge. 38 Removing of old paint, rust with help of power tool and preparing the surface to various standards (ASA 3.0) before application of primer. The rate will include all tools, plants, labour and other consumables and incidental charges. Nothing shall be paid extra. Except NBSR no.1, 3,4,5 and 6. The surface which are not accessible with the help of power tool shall be prepared with wire brush. 39 Applying surface tolerant epoxy coating in two coats with epoxy based primer with minimum DFT of 200 microns at all locations wherever required and volume of solids not less than 75%. Paint is to be applied with spray painting, in place where its inaccessible it may be applied with brush (item to be used where surface is having scaling.) 40 Application of finishing coat epoxy polyurethane system of approved quality brand ot UV resistant coat at all locations and colour to achieve smooth & even surface with minimum volume of solids 57% and of 75 microns thickness of surfaces. 41 Providing and fixing of Anti Birds Spikesmade of high quality of Poly Carbonate, 5 Row 304 mm. Rates are inclusive of screws, cable ties, adhesives, fasteners up to 5 meter Height complete as per direction of Engineer-in-Charge. 42 Supply 5-7.5 HP submersible pump of discharge capacity 50-60 kl/hrs including cost of operation etc complete. 43 Cladding Work 44 Granite cladding work : Providing and laying 30 mm thick mirror polished Sadarhalli Grey/Cheema Pink/Jhalore Beige granite stone work of up to and including sizes of 1200mmX600mm of approved colour/ pattern with 4mm groove all around at all levels for wall linings/ columns/ cladding/skirtings (veneer work) by mechanical arrangement with SS cramps/ brackets, anchor bolts, 6 mm vertical SS pins of approved make and inserts as per drawings and specifications. The cost of making necessary grooves all around stone pieces, chamfering of corner edges and polishing are included. 45 Extra for Red/ Raw Silk/ Tan Brown/ Jet Black granite 46 Removal of old expansion joint, repair of site and providing & fixing of BITUFLEX close cell form twice for overlaping of close cell form joints filling of POLYDEEN GROUTFAST or equivalent non curing mortar and applying POYDEE liquid membrane or equivalent on the entire area of expansion joint mfg by M/S Greensboro Polychem Pvt. Ltd Or equivalent and fixing of 6 mm thick and 150 mm wide aluminium sheet one with sliding screw complete as per direction of Engineer- In-Charge 47 Polishing and buffing of SS 304 railing/SS surface provided in metro stations with minor grinding(as required) and removing stains/blemish with proper rubbing and polishing. The surface with suitable material and finally buffing the surface with high speed buffing machine using buffing material complete as per dierection of Engineer In Charge. The work will be carried out in non revanue hours and rates are inclusive of all taxes man power material, tools and plants, CO and OH etc all complete. 48 Providing skilled manpower such as welder/fitter for welding works along with welding machine to carry out welding as per direction of Engineer-In-charge including cost of tools, safety equipments,consumable(electrodes) etc. 49 Providing semiskilled manpower such as Plumber/carpentor/mason/ for plumbing/sewerage/carpentory/masonary, rectification works with all required T&P complete as per direction of Engineer-In-charge. 50 Providing unskilled manpower such as helper/beldar etc for miscelleneous Civil works with all required T&P as per direction of Engineer-In-charge. 51 Supply of potable water through water tankers o capacity 5000 liters at stations of JMRC from MSOR-BICP
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
17.
Educational and Research Institute #10502902 Price Bid
Supply Of Library Books , Library Books , Introduction To Database Management System P.K. Yadav , Database Management Systemp.K. Yadav , Concepts Of Database System P.K. Yadav , Software Project Managementrajiv Chopra , Software Testing Rajiv Chopra , Software Testing And Quality Assurance Rajiv Chopra , An Integrated Approach To Software Engineering Rajiv Chopra , Internet Of Things ( Iot ) Rajiv Chopra , Object Oriented Software Engineeringrajiv Chopra , Introduction To Microprocessor Rajiv Chopra , Requrements And Estimation Techniques Rajiv Chopra , Fundamentals Of Computing Rajiv Chopra & Rishbh Anand , An Introduction To Automata Theory & Formal Languages Adesh K. Pandey , Introd. To Automata Theory & Formal Lang.Adesh K. Pandey , Fundamentals Of Compiler Designadesh K. Pandey , Concepts Of Complier Designadesh K. Pandey , Concepts Of E-Commerceadesh K. Pandey , Internet Fundamentalsadesh K. Pandey , Network Security & Administrationadesh K. Pandey , Internet & Web Designingadesh K. Pandey &Er.Neha Dutta , Introduction To E-Commerce & Erpadesh K. Pandey , A Textbook Of Compiler Designadesh K. Pandey , Elements Of Compiler Designadesh K. Pandey , Theory Of Automata And Computationadesh K. Pandey , Theory Of Computationadesh K. Pandey , Fundamentals Of Electronics Commerce Adesh K. Pandey , Internet Programming Using Javapandey & Pandey , Fundamentals Of Computer Programming In Cs.K.Jha , System Analysis & Designs.K.Jha , Programming In Cs.K.Jha , Pc Organization S.K.Chauhan , Pc Upgrading Maintenance & Trouble Shooting Guide , Neural Network & Fuzzy Logicvinoth Kumar And R.Saravana Kr. , Soft Computingk.Vinoth Kumar , Fundamentals Of Soft Computingk.Vinoth Kumar , Computer Concepts & Programming In Camit Kumar Mishra , Basic Computer Engineeringamit Kumar Mishra , Introduction To Computer Systemamit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , A Textbook Of Computer Architecture Amit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , Computer System And Programming In C Amit Kumar Mishra , Computer Architecture & Organizationamit Kumar Mishra , Information Security And Cyber Laws Amit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , Computer Architecture Amit Kumar Mishra , Computer Programming Amit Kumar Mishra , Fundamentals Of Computer And Programming Amit Kumar Mishra , Software Engineeringbali And Bali , Fundamentals Of Software Engineeringbali And Bali , Thinking In C++ Rajesh Kocher & Sunil K. Pandey , Learn Autocadrajesh Kocher & Sunil K. Pandey , Fundamentals Of Computer Programming And Itsunil K. Pandey& V.K. Jain , Object Oriented Programing With C ++ Sunil K. Pandey& Rajesh Kochher , Programming Language Nitin Upadhyay , The Design & Analysis Of Algorithmsnitin Upadhyay , Data Structures And Algorithms Using C Nitin Upadhyay , Question Bank In Computer Sciencenitin Upadhyay, Pankaj Sharma , Computer Networks Dr. Sanjay Sharma , Elements Of Computer Networks Dr. Sanjay Sharma , Computer Networks Dr. Sanjay Sharma , A Course In Computer Networksdr. Sanjay Sharma , Introduction To Computer Networks Dr. Sanjay Sharma , Computer Networks-I Dr. Sanjay Sharma , Advanced Computer Networksdr. Sanjay Sharma , Computer Networks-Ii Dr. Sanjay Sharma , Principles Of Computer Networks Dr. Sanjay Sharma , Digital Logic Design Dr. Sanjay Sharma , A Textbook Of Computer Network Dr. Sanjay Sharma , Fundamentals Of Computer Network Dr. Sanjay Sharma , Introduction To Web Technologypankaj Sharma , Fundamentals Of Web Technologypankaj Sharma , Working With Artificial Intelligencepankaj Sharma , Web Engineering Pankaj Sharma , Manet And High Speed Networkspankaj Sharma , Computer Organization Pankaj Sharma , Computer Architecture & Organizationpankaj Sharma , System Programmingpankaj Sharma , Expert System Pankaj Sharma , Information Security & Cyber Lawspankaj Sharma , System Programming & System Admin. Pankaj Sharma , Rapid Application Devlop.Using Visual Basic & Visual C++Pankaj Sharma , Parallel Algorithms Pankaj Sharma , Pattern Recognitionpankaj Sharma , Web Developmentpankaj Sharma , Information Storage & Managementpankaj Sharma , Web Engineering Pankaj Sharma , System Administration Pankaj Sharma , Information Security Pankaj Sharma , Cloud Computing Pankaj Sharma , Introduction To Web Engineering Pankaj Sharma , Web Administration Pankaj Sharma , Dot Net Framework With C# Programming Dr. Lalit Arora , Object Oriented System With C++ Dr. Lalit Arora , Object Oriented System With Javadr. Lalit Arora , Internet & Javadr. Lalit Arora , C# Using .Net Frameworkdr. Lalit Arora , Java Programming & Web Site Designdr. Lalit Arora , Object Oriented Techniques Java Dr. Lalit Arora , Object Oriented Programing Using C ++Dr. Lalit Arora , It Skills And Technology Dr. Lalit Arora , Concept Of Programming And Oopsdr. Lalit Arora, Dr. Raj Kumar & Dr. Anjali , Computer Organization & Architecture Dr. Lalit Arora, Dr. Raj Kumar & Dr. Anjali , Computer Graphicsudit Agarwal , Introduction To Computer Graphicsudit Agarwal , Data Structures Using C Udit Agarwal , Data Structures Udit Agarwal , Software Engineeringudit Agarwal , Distributed Systems Udit Agarwal , Distributed Computing Udit Agarwal , Data Mining And Data Warehousingudit Agarwal , Computer Graphics And Multimedia Udit Agarwal , Programming For Problem Solving Udit Agarwal , Operating Systemvijay Shukla , Multimedia System, Technology & Communication Sujata Pandey , Data Mining & Data Ware Housing , Network Programmingkadambri Agarwal , Programming Languages Kadambri Agarwal , Network Technologykadambri Agarwal , System Network Administration Kadambri Agarwal , Graph Theoryk.Patrai , Discrete Structures & Graph Theoryk.Patrai , Mobile Computingvishnu Sharma , Advances Mobile Computingvishnu Sharma , A Course In Electrical Technologyj.B Gupta , A Course In Electrical Technology-Ij.B Gupta , A Course In Electrical Technology-Iij.B Gupta , A Course In Electrical Technology-Iiij.B Gupta , Generation & Economic Considerationsj.B Gupta , A Course In Electrical Powerj.B Gupta , A Course In Power Systems J.B Gupta , Theory & Performance Of Electrical Machinej.B Gupta , Utilization Of Electric Power & Electric Tractionj.B Gupta , Utilization Of Electrical Energy And Traction J.B.Gupta, R. Manglik, R. Manglik , Switchgear & Protectionj.B Gupta , A Course In Electrical Installation Estimating & Costingj.B Gupta , Fundamentals Of Electrical & Electronics Engineering J.B Gupta , Transmission & Distribution Of Electrical Powerj.B Gupta , Basic Electrical Engineeringj.B Gupta , Basic Electricity J.B Gupta , Electrical Measurements & Measuring Instrumentsj.B Gupta , Electrical Machines-Ij.B Gupta , Electrical Machine - Iij.B Gupta , An Integrated Course In Electrical Engineering J.B Gupta , Explanation / Solutions To An Integrated Course In Electrical Engineering J.B Gupta , An Integrated Course In Electrical Engineering Volume I J.B Gupta , An Integrated Course In Electrical Engineering Volume Ii J.B Gupta , Question Bank In Electrical Engineeringj.B Gupta , Question Bank In Electrical Engineering Volume I J.B Gupta , Question Bank In Electrical Engineering Volume Ii J.B Gupta , A Text Book Of Electrical Engineeringj.B Gupta , Electrical Science J.B Gupta , Electromechanical Energy Conversionj.B Gupta , Electromechanical Energy Conversion- Ij.B Gupta , Electromechanical Energy Conversion- Iij.B Gupta , Electrical Machines ( Ac, Dc Machine ) J.B Gupta , A Text Book Of Electrical Technologyj.B Gupta , Electrical Machines & Automatic Controlj.B Gupta & Hasan , Elements Of Power Systems J.B Gupta , Power System Analysis J.B Gupta , Fundamentals Of Switchgear & Protectionj.B Gupta , Electrical Engineering Materials & Semiconductor Devices J.B Gupta , Basic Electrical & Electronics Engineering J.B Gupta , Electrical Machines-Ij.B Gupta , Electrical Machines-Ii J.B Gupta , Electrical Technologyj.B Gupta , Basic Electrical Engineeringj.B Gupta , Fundamentals Of Electrical Engineering J.B Gupta , Elements Of Electrical Engineering J.B Gupta , Basic Electrical Engineering J.B Gupta , A Textbook Of Electrical Science J.B Gupta , A Textbook Of Electrical Engineering Rajeev Manglik , Power System & Protectionn.K.Datta , Theory & Performance Of Electrical Machine Design Dr. N.K.Datta , Principles Of Electrical Machine Designr.K. Agarwal , Electrical Engineering Materialsrakesh Dogra , Electrical Engineering Drawing-Isurjit Singh , Electrical Engineering Drawing-Iisurjit Singh , Electrical Measurements & Measuring Instrumentsm.L.Anand , Basic Electrical Engineeringtarlok Singh , Installation Commissioning & Maintain. Of Elect. Equip.Tarlok Singh , Electrical Measurement & Measuring Instrumentstarlok Singh , Elements Of Electrical & Electronics Engineering Tarlok Singh , Utilization Of Electric Energytarlok Singh , Electrical Machine-Itarlok Singh , Electrical Machine-Iitarlok Singh , Electrical Power-Iitarlok Singh , Fundamentals Of Electrical Engineering Tarlok Singh , Electrical Science Tarlok Singh , Transmission & Distributiontarlok Singh , Modern Electric Traction Tarlok Singh , Energy Managementdr. Sanjeev Singh, Umesh Rathore , Basic Instrumentation System & Programmable Logic Controllerumesh Rathore , Industrial Instrumentationumesh Rathore , Programmable Logic Controller And Microcontrollers Umesh Rathore , A Textbook Of Electrical Workshop Practices Umesh Rathore, Naresh Kumar Sharma , A Textbook Of Energy Science & Engineering Umesh Rathore , Fundamentals Of Managementdr. R.C.Bhatia , Sub-Station Engineering Design, Concepts & Computer Applications Er. R.S.Dahiya , An Introduction To Electric Traction Sachidananda Mallik & Rupali G. Nazar , Fundamentals Of Managementrenu Rana , Special Electrical Machines Simmi P Burman , High Voltage Engineering Simmi P Burman & Nikita Gupta , Electrical Engineering Laboratory Practice P. Tiwari & S. Sairola , Ehv-Ac, Hvdc Transmission And Distribution Engineering Sanjay Kumar Sharma , Basic System Analysissyed Hasan Saeed & Faizan Arif Khan , Power Quality Simmi P. Burman & Bipin Singh , Scada And Energy Management System Er. Tanuj Kumar Bisht , Computer Aided Design Of Electrical Machines V.K. Maurya, Ritu Raj Jallan, Shasya Shukla , A Textbook Of Power System Operation And Control K. Nisha , Electromagnetic Field Theory Syed Hasan Saeed & Faizan Arif Khan , Installation Maintenance And Repair Of Electrical Machines And Equipments Madhvi Gupta , Electrical Engnineering Design, Drawing & Estimation Madhvi Gupta, Ankit Agarwal , Control Systems S.P. Meher , Fundamentals Of Smart Grid Technology Bharat Modi, Anu Prakash & Yogesh Kumar , Electric Vehicle Dr. Nitesh Tiwari , Ssc-Je-Question Bank In Electrical Engineering J.B.Gupta , Ace Academy Gate 2024 Ace Publication , Gate / Ese / Psus Electrical Handbook Ace Publication , Ace Academy Ese Vol 1And Vol 2 Ace Publication , Yct Electrical Engineering Je-Vol And Vol 2 Yct Publications , Yct Electrical Engineering Ae-Vol And Vol 2 Yct Publications , Basic Electrical Engineering Vol 1S Chand Publication, B L Theraja , Ac & Dc Machine Vol 2 S Chand Publication, B L Theraja , Transmission And Distribution Utilisation S Chand Publication, B L Theraja , Electronics Devices And Circuits S Chand Publication, B L Theraja , Power Electronics Khanna Publications, Dr. Ps Bhimbra , Fundamentals Of Electrical Circuits Mc Graw Hill, Charles K.Alexander , Objective Electrical Technology V.K.Mehta, Rohit Mehta , Principles Of Power System V.K.Mehta, Rohit Mehta , Principles Of Electrical Machines V.K.Mehta, Rohit Mehta , Control Of Machines New Age International , Sk Bhattacharya , Linear Integrated Circuits New Age International , Sk Bhattacharya , Programmable Logic Controllerpearson, John.R.Hackworth , Principles Of Electromagnetics Oxford, Sadiku & Kulkarni , A Course In Electrical & Electronics Measurements And Instrumentation Dhanpat Raj & Co , A K Sawhney , Fundamentals Of Digital Circuits Phi, A.Anand Kumar , Power Electronics Devices Circuits And Applicationpearson, Muhammad H. Rashid , Electrical Power System C.L.Wadhwa, New Age International , Modern Power System Analysis Mc Graw Hill, D.P.Kothari , Electrical Machinery Khanna Publications, Dr. Ps Bhimbra , Generalized Theory Of Electrical Machines Khanna Publications, Dr. Ps Bhimbra , Electronics Devices And Circuits S.Salivahanan, Mc Graw Hill , Micro Controller Principles And Applications Ajit Pal, Eastern Economy Edition , Power Plant Engineering Mc Graw Hill, P K Nag , Power System Engineering Lp, R.K.Rajput , Non Conventional Energy G D Rai, Khanna Publication , Basic Electrical And Electronics Engineering Mc Graw Hill, D.P.Kothari , Repair And Maintenance Bpb Publications, Shashi Bhushan Sinha , Electrical Applications Haynes , Electronic Devices And Circuitsj.B.Gupta , Basic Electrical And Electronics Engineeringj.B.Gupta , Linear Integrated Circuitsj.B.Gupta , Fundamentals Of Analog Electronicsj.B.Gupta , Basic Electronics J.B.Gupta , Electrical & Electronics Engineering J.B.Gupta , A Textbook Of Basic Electronics J.B.Gupta, Rajeev Manglik, Rohit Manglik , Analog Devices And Circuits J.B.Gupta , Fundamentals Of Electronics Devices & Circuits J.B.Gupta , Electronic Devices & Circuits Dr. Sanjay Sharma , Analog & Digital Electronicsdr. Sanjay Sharma , Signal & Systemsdr. Sanjay Sharma , Digital Signal Processing Dr. Sanjay Sharma , Electronics Circuits Dr. Sanjay Sharma , Digital Electronics Dr. Sanjay Sharma , Digital Communications Dr. Sanjay Sharma , Fundamentals Of Electronic Devicesdr. Sanjay Sharma , Digital Communication Dr. Sanjay Sharma , Digital Signal Processing Dr. Sanjay Sharma , Principle Of Digital Signal Processingdr. Sanjay Sharma , Analog & Digital Communication Dr. Sanjay Sharma , Signal & System Dr. Sanjay Sharma , Fundamentals Of Communication Engineering Dr. Sanjay Sharma , Communication Engineeringdr. Sanjay Sharma , Digital Electronics And Logic Design Dr. Sanjay Sharma , Digital Circuits & Systems Dr. Sanjay Sharma , Wireless Communication Systems Dr. Sanjay Sharma , Electronic Circuits Dr. Sanjay Sharma , Digital Electronics & Design Aspects Dr. Sanjay Sharma , Electronic Devices Dr. Sanjay Sharma , Signals & Systems Dr. Sanjay Sharma , Digital Design Dr. Sanjay Sharma , Analog And Digital Electronics Dr. Sanjay Sharma , A Textbook Of Electronics Engineering Dr. Sanjay Sharma , Fundamentals Of Digital Electronics Dr. Sanjay Sharma , Fundamentals Of Digital Image Processing Dr. Sanjay Sharma , Digital Image Processing Dr. Sanjay Sharma , Wireless Communication System Dr. Sanjay Sharma , Mobile Computing Dr. Sanjay Sharma , Switching Theory And Logic Design Dr. Sanjay Sharma , Essentials Of Computer Networks Dr. Sanjay Sharma , Data And Computer Communications Dr. Sanjay Sharma , Fundamentals Of Switching Theory & Logic Design Dr. Sanjay Sharma , Essentials Of Analog Communication Dr. Sanjay Sharma , Data Communication And Computer Networks Dr. Sanjay Sharma , A Textbook Of Data Communication And Networks Dr. Sanjay Sharma , Essentials Of Wireless Communication Dr. Sanjay Sharma , Fundamentals Of Electronics Engineering Dr. Sanjay Sharma , Wireless Communicationsdr. Sanjay Sharma , Electronic Devices & Circuits Dr. Sanjay Sharma , Fundamentals Of Digital Signal Processing Dr. Sanjay Sharma , Fundamentals Of Analog Communication Dr. Sanjay Sharma , A Textbook Of Signals & Systems Dr. Sanjay Sharma , Solid State Devices & Circuits Dr. Sanjay Sharma , Electronics-I Dr. Sanjay Sharma , Signal Processing And Linear Systems Dr. Sanjay Sharma , Emerging Domain In Electronics Engineering Dr. Sanjay Sharma , Circuits & Systemsk.M.Soni , Circuit Analysis And Synthesis K.M.Soni , Advanced Control Systemsk.M.Soni , Network Analysis & Systhesisk.M.Soni , Network Analysisk.M.Soni , Network Theory K.M.Soni , Fundamentals Of Network Analysis & Synthesis K.M.Soni , Basic System Analysisk.M.Soni , Signals And Systems K.M.Soni , Digital Electronicsb.R.Gupta And V.Singhal , Consumer Electronicsb.R.Gupta , Power Electronicsb.R.Gupta And V.Singhal , Introduction To Electric Drivesb.R.Gupta And V.Singhal , Question Bank Electronics & Communicationengineeringb.R.Gupta And V.Singhal , Fundamentals Of Electric Drives And Control B.R.Gupta And V.Singhal , Industrial Electronics & Instrumentationsunil Kumar , Optical Fiber Communicationsapna Katiyar , Satellite Communicationsapna Katiyar , Advanced Communication Systemsapna Katiyar , Electronic Switchingsapna Katiyar , Introduction To Optical Communicationsapna Katiyar , Telecommunication Networkssapna Katiyar , Fundamentals Of Optical Fiber Communicationsapna Katiyar , A Textbook Of Optical Fiber Communication Systems Sapna Katiyar , Introduction To Satellite Communcation Sapna Katiyar , Tv And Satellite Communications Sapna Katiyar , Vlsi ( Technology, Design & Basics Of Microelectronics ) Sapna Katiyar , 8051 Microcontroller & Embedded Systemsampath K. Venkatesh , Digital Circuit System Using Vhdlneelu Chaudhary And Shipra Gupta , Digital Logic & Design Pratima Manhas And Shaveta Thakral , Digital Electronicspratima Manhas And Shaveta Thakral , Vlsi Design Pratima Manhas & Shaveta Thakral , Introduction To Microprocessors & Interfacingaashutosh Gupta , Electromagnetic Fields & Wavesr.Gowri , Wireless Communicationaman Kundra And Amrita Sandhu , Trouble Shooting & Maintenance Of Elect. Equipmentsk.Sudeep Singh , Fundamentals Of Television & Radar Engineering K.K Sharma , Fundamentals Of Radar, Sonar & Navigation Engineering K.K Sharma , Fundamentals Of Data Communicationk.K Sharma , Digital & Analog Communicationk.K Sharma , Microwave & Radar Engineeringk.K Sharma , Antenna & Wave Propagation A.K.Gautam , Principle Of Communication Engineering A.K.Gautam , Communication System-Ia.K.Gautam , Microwave Engineering A.K.Gautam , Control System Hasan Saeed , Digital & Analog Communicationbrijesh Verma , Mobile Communicationbrijesh Verma , Telemetry & Data Transmissionr.N.Baral , Electronics Devices & Circuits-I M.L.Anand , Bio-Medical Signal Processing Rakesh Kumar , Medical Electronics O.N. Pandey & Rakesh Kr. , Instrumentation And Process Control O.N. Pandey , Electromagnetic Field Theory Parul Dawar , Digital Circuit And Systems Shipra Gupta , Vlsi Designc.P Verma , Introduction To Vlsi Circuits & Systems Deepak Garg , Vlsi Technology Deepak Garg , Fundamentals Of Vlsi Design Deepak Garg , Basics Of Vlsi Design With Vhdl Deepak Garg , Microprocessor & Interfacingn. Marriwala , Embedded System Design N. Marriwala & Ritu Khullar , Fundamentals Of Radar & Navigation Sachin Gupta , Optical Communication Sachin Gupta , Microwave And Radar Engineeringravi Garg & Ankaj Gupta , Antenna And Wave Propagation Prashant Pandey , Digital Electronics Preeti Sehrawat , Electronic Circuits M. Elangovan , Electromagnetics And Antennas H. Singh , Optoelectronics & Optical Communication Satyajit Das , Control Systems Engineering Dr. S. Panda, S. Padhy & S.R. Das , Microcontroller And Embedded Systems Ankaj Gupta , Microprocessors And Microcontrollers Ankaj Gupta , Fundamentals Of Microprocessors And Embedded Systems Ankaj Gupta , Microprocessors Shweta Goyal & Swati Gargust , Industrial Electronics And Control Of Drives Shweta Goyal & Swati Gargust , Engineering Economics And Industrial Management Dr. R.K. Singal & Er. Rishi Singal , Microwave & Radar Engineering Er. Rajesh Dhiman , Embedded Systems Anurag Arora , Wireless Sensor Networks Sunil Gupta & Dr. Harsh K. Verma , Probability, Random Variables And Stochastic Methods Himanshu Chaurasiya & Dr. K.M. Soni , Relational Database Management System Pooja Sharma & D.S. Sehrawat , Semiconductor Devices And Circuits C.S. Murlidharan Sharma , Industrial Power Electronics Partha K. Ganguly , An Insight To Matlab & Simulink Dr. Shailender Gupta & Bharat Bhushan , Fundamentals Of Optical Communication & Networks Shila Ghosh, Somali Sikder , Digital Image Processing Ketki Kshirsagar, Rajeshree Shinde , Embedded System & Microcontroller Manish Verma & K.B. Singh , Electronic Design Automation & Logic Synthesissarita Chauhan , Artificial Intelligence For Engineers Malvika Gupta, Medha Malik , Principles Of Electronics Dr. S.K. Bhattacharya , Machine Learning Dr. Himanshu Sharma , Strength Of Materials R.S.Khurmi S.Chand & Company Ltd, New Delhi , Strength Of Materials S.Ramamirtham Dhanpat Rai , Engineering Mechanics R K Bansal Laxmi Publications Pvt.Ltd. , Building Materials P.C.Varghese Prentice-Hall Of India ( P ) Ltd., I Edition , Building Construction Dr. B.C. Punmia Laxmi Publications ( P ) Ltd New Delhi. , Building Construction S.C.Rangwala Charotar Publishing House, Vii Edition , Surveying Volume I Punmia.B.C. Ashok K.Jain & Arun K. Jain Lami Publications Private Limited, 16Th Edition , Surveying Volume Ii & Iii Punmia.B.C, Ashok Jain & Arun K. Jain Lami, Publications Private Limited., 15 Th Edition, , Fundamentals Of Surveying S. K. Roy Phi Learning Private Limited , Building Planning And Drawing Dr.N.Kumaraswamy Charotor Publishing House , Building Planning And Construction G. Vaidhyanathan, I. Kulasekaran, G. Sathish Kumar , A Guide To Civil Engineering Drawing V.R.Thothathri , Theory Of Structures S. Ramamrutham Dhanpat Rai Publications, New Delhi , Theory Of Structures B.C. Punmia, Ashok Jain & Arun Jain Laxmi Publications , Analysis Of Structures V.N. Vazirani & M.M. Ratwani , Fluid Mechanics R.K. Bansal Lakshmi Publications , Hydraulics, Fluid Mechanics And Hydraulics Machines S. Ramamirtham Dhanpat Rai & Sons, New Delhi , Hydraulics, Fluid Mechanics And Hydraulics Machines K.R. Arora Standard Publishers & Distributors, New Delhi , Highway Engineering S.K.Khanna And C.E.G Justo Nem Chand And Bros, Roorkee. , Highway Engineering Rangwala Charotor Publishing House Pvt. Ltd , A Text Book Of Transportation Engineering S P Chandola S Chand & Company Ltd , Bridge Engineering Rangawala Charotor Publishing House , Reinforced Concrete Design N Krishnaraju New Age International Publications, 2012 , Is 456-2000 , Steel Structures Hand Book Sp16 , Limit State Design Of Reinforced Concrete B C Punmia Laxmi Publications, 2007 , Design Of R C C And Structural Elements ( Rcc Vol I ) S S Bhavikatti, New Age International Publications, 2011 , Environmental Engineering B C Punmia Lami Publications, 2010 , Waste Water Engineering B C Punmia , Laxmi Publications, 2010 , Environmental Engineering A.Kamala, D.L.Kanthraotata Mcgraw Hill Publishing Company Ltd., New Delhi , Concrete Technologym.S. Shetty S.Chand & Company Pvt. Ltd. New Delhi. , Soil Mechanics And Foundation Engineering B C Punmia Laxmi Publications ( P ) Ltd., 2005 , Civil Engineering Drawings.C. Rangwala Charotor Publishing House , Construction Management Sanga Reddy. S Kumaran Publications, Coimbatore , Steel Structures Dr.Subramaniam , Town Planning S.C. Rangwala , Principles And Practice Of Town And Country Planninglewis B. Keeble Estates Gazette, University Of Michigan, 2010 , Estimating & Costing L.N.Dutta Dhanpat Rai & Sons , Estimating & Costingrangawala , Charotor Publishing , Quantity Surveying & Valuation N.A.Shaw Khanna Publishers; , Civil Engineering Competitionsbooks R.Agor Khanna Publishers; , Civil Engineering ( Objective Type ) P Jaya Rami Reddy , Laxmi Publications , Reinforced Concrete Design S.Unnikrishna Pilla & Devadas Menon, Mc Graw Hill Publications , Limit State Design Of Steel Structures S K Duggal , Mc Graw Hill Publications , Basic And Applied Soil Mechanics , Gopal Ranjan & A S R Rao, New Age International Publications , Fluid Mechanics And Fluid Power Engineering Dr. D.S Kumar , Basics Of Mechanical Engineering Dr. D.S Kumar , Mechanical Engineering ( Objectives ) Dr. D.S Kumar , Refrigration And Air Conditioner Dr. D.S Kumar , Total Quality Management Dr.K.C.Arora , Engineering Drawing , Ps Gill , Textbook Of Machine Drawing, Ps Gill , Geomatric Dimensioning And Tolerancing , Ps Gill , Computer Aided Drafting Using Autocad , Ps Gill , Learning Autocad , Ps Gill , Auto Cad 2D Design Fundamentals , Ps Gill , Auto Cad 3D Models Fundamentals Ps Gill , Operation Research , Ap Verma , Textbook Of Industrial Management , Ap Verma & N.Mohan , Industrial Engineering And Management , Ap Verma , Stem Tables Rk Singal , Manufacturing Practices ( Workshop Practices ) Rk Singal , Engineering Metrology And Instrumention , Rk Rajput , Strength Of Materials , Rk Rajput , Textbook Of Material Science , Callister , Workshop Technology , Virendra Narula , Manufacturing Process , Virendra Narula , An Intoduction To Nc And Cnc , S.Vishal , Computer Aided Manufacturing, S.Vishal , Automobile Engineering , Km Moeed , Manufacturing Process I Sandy Khippal , Manufacturing Process Ii Sandy Khippal , Principals Of Powder Meatallurgy , Ps Gill , Inspection And Quality Control, Ap Verma , Automation Of Robotics, Khushdeep Goyal , Industrial Automation And Robotics, Khushdeep Goyal , Cnc Machines And Automation , Khushdeep Goyal , Production Planing And Control , Rk Singal , Theroy Of Machines , Rk Singal , Data Book For Designing Machine Elements , Arunkumar , Entreprenurship Development, Ranbirsingh , Unconventional Manufacturing Process , Rahul Jain , Mechanics Of Solids , Timoshenko , Engineering Mechanics , Timoshenko , Mechanics Of Solids , Egor P Popov , Fluid Mechanics And Fluid Power Engineering, Frank M White , Matlab For Dummies , John Mueller , Machine Learning For Dummies , John Mueller , Thermodynamics , Cengel , The Functional Aspects Of Communication Skills, Dr. P. Prasad , Professional Communication, Dr. P. Prasad , Universal English ( In The Twenty-First Century ) Dr. P. Prasad , Effectual Communication Skills , Bhupender Kaur , Engineering Physics, Dr. Abhijit Nayak , Essentials Of Physicsdr. Rakesh Dogra , Engineering Physics ( Aicte ) Dr. Rakesh Dogra , Applied Physics- Imanpreet Singh , Applied Physics -Iimanpreet Singh , Laser Systems & Applications, Dr. Rajesh Mishra , Engineering Physics-I, Dr. Rajesh Mishra , Fundamentals Of Polymer Science & Technology, Anshu Srivastava & Shakun Srivastava , Nuclear Science, Chanchal Garg , Petrochemicals, Anjana Srivastava , Impact Of Science Technology On Society, Ishwar Singh , Introduction To Bioscience , Dr. O.N. Pandey , Introduction To Bioscience Sweety Israni , A Textbook Of Nanoscience , Dr. Rakesh Kumar & Dr. Kamala Pati Tiwary , Professional Communicationdr. Raavee Tripathi , Technical Writing , Dr. O.N. Pandey , Engineering Economics , Dr. O.N. Pandey , Numerical Analysis Dr. Surbhi Gupta & Dr. Abhilasha Sharma , Business Environment , Anita Sengar , Numerical Methods , Girish Nayyar , Human Values And Professional Ethics , Smriti Srivastava , Discrete Mathematical Structures , Adesh K. Pandey & Rakesh Dube , Effective Technical Communication , Dr. Bharti Kukerja, Dr. Anupama Jain , Human Behaviour , Dr. Amit Jain , Organisational Behaviour , Er. Ishwar Singh, Dr. Bratpal Singh , Universal Human Values And Professional Ethics , Dr. Ritu Soryan , Soft Skills , Dr. Ritu Soryan , Communication Skills, Dr. Ritu Soryan , Constitution Of India , Richa Chaudhary, Arunima Mishra, Imran Khan , Concise Engineering Physics , Dr. Shiva Kant Pathak , Discrete Mathematicsanjana Gupta , Discrete Structures, Adesh K. Pandey , Discrete Structure, Kalika Patrai , Applied Mathematics- I, Dr. Hari Arora , Applied Mathematics- Ii, Anita Sachdeva & Hari Arora , Applied Mathematics- I, Dr. J.S.Bindra And K.S.Gill , Applied Mathematics- Ii, Dr. J.S.Bindra And K.S.Gill , Applied Mathematics- Iii, Dr. J.S.Bindra And K.S.Gill , Elements Of Engineering Mathematics- I Dr. V.P. Mishra , Elements Of Engineering Mathematics- Ii, Mishra & Mishra , Elements Of Engineering Mathematics- Iii, Mishra & Mishra , Engineering Mathematics-I , Mishra & Mishra , Question Bank In Engineering Mathematics , Mishra & Mishra , A Textbook Of Applied Mathematics-I, Dr. Hari Arora , A Textbook Of Applied Mathematics-Ii , Dr. Hari Arora , A Textbook Of Applied Mathematics-Iii , Dr. Hari Arora , A Textbook Of Applied Mathematics-Iv , Dr. Hari Arora , A Textbook Of Engineering Mathematics-Ii , Dr. Hari Arora , A Textbook Of Engineering Mathematics-I ( Calculus & Linear Algebra ) , Dr. Hari Arora , Applied Mathematics-Ii ( Previous Year Papers ) Dr. Hari Arora , Numerical Methods And Optimization Dr. Hari Arora , Probability & Statistics Dr. Hari Arora , Differential Equations And Complex Analysis Dr. Hari Arora , Numerical Methods For Engineers And Scientists Dr. Hari Arora , Engineering Mathematics-Iii Amit Gupta , Mathematics ( Cbse ) ( Class - Ix ) Upadhyay & Upadhyay , Mathematics ( Cbse ) ( Class - X ) Upadhyay & Upadhyay , Mathematics ( Cbse ) ( Class - Xi ) Upadhyay & Upadhyay , Mathematics For Mechanical Engineering ( A Solution Manual ) Salman Hussien Omran, Laith Jaffer Habeeb , A Textbook Of Finite Element Method , Pushpam Kumar Sinha , Engineering Chemistry , Dr. Sunita Rattan , Engineering Chemistry With Experiments , Dr. Sunita Rattan , Comprehensive Engineering Chemistry, Dr. Sunita Rattan , Experiments In Applied Chemistry , Dr. Sunita Rattan , Theory & Practical Of Engineering Chemistry, Dr. Sunita Rattan , A Textbook Of Engineering Chemistry , Dr. Sunita Rattan , Engineering Chemistry ( With Experiments ) , Dr. Sunita Rattan , Applied Chemistry- I, Dr. Raman Rani Mittal , Applied Chemistry- Ii, Dr. Raman Rani Mittal , Engineering Chemistry, Dr. Renu Gupta , New Course Engineering Chemistry, Dr. S.K. Bhasin , New Course Engineering Chemistry , Dr. S.K. Bhasin , Realm Of Space Science , Rajeev Garg , A Textbook Of Engineering Chemistry , Dr. Sunita Rattan , A Textbook Of Engineering Chemistry , Dr. Rajshree Khare , Applied Physics ( Theory & Experiments ) , Ritika Sorot Chauhan, Kavindar Tiwari , Applied Chemistry ( Theory & Experiments ) , Dr. Babita Bhardwaj , Junior English Revised , Haydn Richards => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
19.
Housing Urban and Rular Development #10373373 Price Bid
Tender For Strengthening Of Road (Construction Of Rotary And Other Development Works Around Rotary On 45M Wide Road Along Sector-90 And 137) Noida, 1 Demolishing cement concrete manually/ mechanical means and incluiding disposal of material within 50 metres lead as per direction of Engineer-in-charge. Normal 1:3:6 or richer Mix. 2 Demolishing R.C.C work manually/ by mechanical means incluiding stacking of steel bars and disposal of unserviceable materials within 50 metre lead as per direction of Engineer - in-charge. 3 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m,and lift upto1.5m, as directed by Engineer-in-charge. : All kinds of soil. (C.R.) The Contractor has to detect Different utilities like sewer line, water Supply line, electric cable, telephone cable, gas pipe line etc. using utility detecting machine before start of excavation and shall start excavation only after getting permission of Engineer-in- Charge(CR). 4 Filling available excavated earth (excluiding rock) in trenches, plinth , sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering , lead up to 50m and lift upto 1.5m 5 Disposal of building rubbish / malba / similar unserviceable , dismantled or waste materials by mechanical means incluiding loading transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge. Beyound 50 m initial lead, for all leads incluiding all lifts involved. 6 Construction of sub-grade and earthen shoulder with approved obtained from right of way all lifts & leads , transporting to site ,spreading ,grading to required slope and compacted to meet requirement of table no. 300-2 7 By Mix in Place Method Well graded Construction of granular sub-base by providing close graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with front end loader at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. MORT&H Specification 401 Sr No 4.1 8 Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. 9 Prime Coat over WBm/WMM, Providing and applying Primewith SS1 grade bitumen emulsion using emulsion pressure distributor at the rate of 0.70 to 1.00 kg per sqm using mechanical means. 10 (Dense Graded Bituminous Macadam Grading 2 )Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 per centby weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as percomplete in all respects. 11 Providing and applying tack coat using hot straight run bitumen of grade VG-10 incluiding heating the bitumen, sraying the bitumen with mechanically operated spray uint fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : On bituminous surface @ 0.50 kg/sqm. 12 Bituminous Concrete Grading 2 Providing and laying bituminous concrete withhigher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4per centof mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per complete in all respects 13 Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface.Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35-2015 The finished surface to be level, uniform and free from streaks and holes. 14 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering -all work upto plinth level 1:4:8(1cement :4 course sand (zone III ):8 graded stone aggregate 40mm nominal size ). 15 Providing and laying factory made chamferededge Cement Concrete Paver Blocks in Footpath, parks, lawns, drive ways, or light traffic parking etc, of required strenght, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand , compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra san. complete all as per direction of Engineer-in-charge.16.91.1 60mm thick c.c. paver block of M-35 grade with approved color and design & pattern. 16 Centering and shuttering including strutting, propping etc. and removal of form for :Wall any thickness including attached pilasters, buttresses, plinth and string course etc. 17 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete 18 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 19 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying, excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve workability without impaining strength and durability as per direction of the Engineer-in-charge. (Note Cement content considered in this item is @ 330kg/cum.Excess/less cement used as per design mix is payable/recoverable separately). All works up to plinth level. 20 Extra for providing richer mixes at all floor levels. Noe :- Excess/less cement over the specified content used is payable/recoverable separately . Providing M-30 grade concrete inseed of M-25 grade BMC/RMC. ( Note:- Cement content considered in M-30 is @340 kg/cum). 21 Manufacturing, Supplying and fixing retro reflective overhead signage boardmade up of 2mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens tyoe heat activatedretro reflective sheeting conforming to type- III of ASTM-D-4956-01 as approved by Engineer-in-charge, letters, borders etc. as per IRC :67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substratre by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by..........complete as per drawings, specification and direction of the engineer-in-charge ( structural frame workincluding M.S plate to be provided separately. Rectangular area of the sheet only shall be measured for payment)Full Language in orignal file. 22 Providing wall putty on new surface with approved quality material of Berger/JK/Birla of similar make 2 coats 23 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 24 Providing and laying Mastic Wearing course ( as per specifications ) with Industrial bitumen of grade 85/25 conforming to IS : 702, prepared by using mastic cooker and laid to required level and slope, Incluiding providing antiskid surface with bitumen precoated fine grainedhard stone chipping of approved size at the rate of 0.005 cum per 10 sqm and at approximate spacing of 10 cm centre to centre in both directions, pressed into surface protruding 1 mm to 4mm over mastic surface, Incluiding cleaning the surface, removal of debris etc. All complete. ( Considering bitumen using 10.2% as per MORTH specification ) 40mm thick 25 Brick work with common burnt clayF .P.S (non modular ) bricks of class designation 100 in foundation and plinth in : cement mortar 1:4 ( 1 cement : 4 coarse sand ) 26 Providing and laying C.C pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per Engineer- in -charge. (The panel shuttering work shall be paid for separately.) ( Note:- Cement content considered in this item is @330 Kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 27 Fabrication & Manufacturing of Prestressed Hollow Core slab (Hollow area 25 to 30%) of different thickness & modular width 1200 mm in Controlled Factory Environment with approved methodology confirming to IS 10297:1982 by using long line casting method having arrangement ............as per the direction of the Engineer-in-charge. (Cost of strands should be paid separately). Note: Excess/less cement over the specified cement content used as per design mix is payable/recoverable separately) including steel & Transport charge.Full Language in Orignal file. 28 Boring/drilling bore well of required dia for casing /strainer pipe, by suitable method prescribed in IS : 2800 (part I), incluiding collecting samples from different strata, preparing and submitting strata chart/ bore log, incluiding hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 23.1.1 All types of soil23.1.1.1300 mm dia. 29 Supplying , assembling, lowering and fixing in verticle position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, incluiding required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 23.3.3 200 mm dia. 30 Supplying , Filling , spreading & Leveling stone Boulders of size range 5cm to 20cm , in Recharge Pit , in the required thickness, for all leads & lift , all complete as per direction of Engineer-in-charge. 31 Supplying , Filling , spreading & Leveling Gravels of size range 5mm to 10mm , in the Recharge Pit , over the existing layer of boulders, in required thickness, for all leads & lift , all complete as per direction of Engineer-in-charge. 32 Supplying , Filling , spreading & Leveling Coarse sand of size range 1.5 mm to 2 mm , in the Recharge Pit , over the gravel layer , in required thickness, for all leads & lift , all complete as per direction of Engineer-in-charge. 33 Providing and fixing Bail plug / Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS : 2800(part 1). 34 centering and shuttering incliuding strutting propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform. 35 Providing and fixing plan non- asbestos cement sheet strip in joints pavement / terrazo flooring 100mm wide & 6mm thick (based on item no. 11.13.1/195/DAR-2018 vol-1 36 Taking out existing CC interlocking paver blocks from footpath/ central verge, incluiding removal of rubbish etc, disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-charge. 37 Providing and placing in position 100 mm thick factory made machine batched & machine mixed Precast RCC Rectangular Covers on drains of footpath of various sizes, of M-25 grade cement concrete for RCC work, including cost of centering, shuttering, reinforcement of 8 mm dia TMT bars of Fe grade @ maximum 100mm c/c on both ways, neat cement punning on finished surface, propoerly encased on all edges with 1.6 mm thick, 100 mm wide MS sheet duly painted over primimg coat, reinforcement to be welded at edges with MS sheet and providing 2 Nos. 12 mm dia bar for hooks etc I/c cost of cartage, all leads & lift, handling at site etc. all complete as per direction of Engineer-in-Charge. 38 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc. incluiding cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, incluiding welding and bolted with special shaped washers Electric resistance or induction bult welded tubes etc complete. 39 Steel work welded in built up sections/ framed work, incluiding cutting ,hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required in gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. 40 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 41 12mm Cement plaster of mix : 1:4 (1 cement :4 course sand) 42 Sculpture at rotary.(White marble modern art.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 10
Uttar Pradesh View Result →
20.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
21.
Rural Development #10370743 Price Bid
Providing Following Materials For Work Constructing Mini Kt Weir Gut No 92 Khar Odha Kansewadi At Chikhalthanwadi Tal Shrigonda Dist Ahmednagar , Providing Following Materials For Work Constructing Mini Kt Wair Gut No 92 Khar Odha Kansewadi At Chikhalthanwadi Tal Shrigonda Dist Ahmednagar , Itemno.1:- Excavation In All Kinds Of Soil & Soft Murum Including Boulders Up To 0.6 M Diameter ( 0.113Cum ) For Canal, Seating Of Embankment, Filter Drains / Catch Water Drains Etc., And Placing The Excavated Stuff Neatly In Dump Area Or For Formation Ofserviceroad / Embankment As Directed Including Cost Of All Materials, Machinery, Labour, Dressing Bed And Sides To Required Level And Profile Etc. Complete With Leads As Below And All Lifts As Directed. A ) For 15 M Lead , Nala Trenching , Item No.2:- Excavation In Hard Murum Including Boulders Up To 0.6 M Diameter ( 0.113 Cum ) For Canal, Seatingofembankment, Filterdrains / Catch Water Drainsetc., And Placing The Excavated Stuff Neatlyin Dump Area Or For Formation Of Service Road / Embankment Including Cost Of All Materials, Machinery, Labour, Dressing Bed And Sides To Required Level And Profile Etc., Complete With Leads As Below And All Lifts As Directed. A ) For 15 M Lead , Itemno.3:-Excavationinsoftrockwithoutblasting Including Boulders Up To 0.6 M Diameter ( 0.113 Cum ) For Canal, Seating Of Embankment, Filter Drain / Catch Water Drains Etc., And Placing The Excavated Soft Rock Neatly In Dump Area Or For Formation Of Service Road Includingcostof All Materials, Machinery, Labour, Dressing Bed & Sides To Required Level And Profile Etc.Complete With Leads As Below And All Lifts As Directed. A ) For 15 M Lead , Itemno.4:-Excavation Inhardrock Of All Toughness Byblastingincludingbouldersabove0.6M Dia. ( 0.113Cum ) Minimizingdamagetosideslopesof Excavationinwaterprism Areabyadoptinganyone Orcombinationoflinedrilling / Pre-Splitting / Smooth Blastingtechniquesandplacingtheexcavatedrock Neatlyinapproveddumpareaincludingcostofall Materials, Machinery, Labour, Levelingbedetc., Complete With Leads As Below And All Lifts As Directed. A ) For 15 M Lead , Providing And Fixing In Position Tmt- Fe - 500 Bar Reinforcementofvariousdiametersforr.C.C.Pile Caps, Footings, Foundations, Slabs, Beamscolumns, Canopies, Staircase, Newels, Chajjas, Lintelspardis, Copings, Fins, Archesetc.Asperdetaileddesigns, Drawingsandschedules.Includingcutting, Bending, Hooking The Bars, Binding With Wires Or Tack Welding And Supporting As Required Complete As Directed. , Item No. 31:- Providing And Laying In Situ Cement Concrete Of Gradem-15Oftrap / Granite / Gneiss / Quartzite / Graded Metal Forpcc With Or Without Surface Reinforcement / Rcc Concreting Requiring Heavy Or Special Type Of Shuttering For Works Of Gallery, Sluice, Spillway Crest, Spillway Downstream Face, Energy Dissipating Structures, Intake Structures, Training Walls, Piers, Abutments Etc. With Concretemixer Withshutteringandscaffolding, Placing, Compacting, Curing With An Initial Lead Of 1 Km And All Lifts Etc. Complete As Directed. ( A ) M-15 ( 20 Msa ) ( Cement 5.64 Bags / Cum ) , Item No.118A:- Straight Needle K.T. Weir Gate-Manufacturing- Manufacturing With Qap & Fabrication Of Kt Weir Needle Gates - Traight Typesize2.15X0.5M-94Kg.Weightasper Relevant Indian Standards With All Material, Mildsteelconfirmingtois2062, Rubber Seal Confirming To Is 4623 & Weldingelectrodes Aws E6013for General Weld Joints. It Includes All Materials, Labour Charges, Machinery Charges, 1Km Lead Charges Of Transportation, Loading And Unloading Charges Of Gate Parts At Site, Inspection & Quality Control Charges, Sand Blasting, Painting With One Coat Of Zinc Rich Primer On Dry Film To Give Total Dry Film Thickness 70 + / - 5 Microns And 2 Coats Of Sloventless Coal Tar Epoxy Paint Applied To Give Minimum Dry Film Thickness Of 150+ / - 5 Micron Per Coat As Per Is 14177. , Providing And Fixing In Position M.S.Channel 150*75 Mm 14.4 Kg / M As Per Design & Drawing Including All Labour Etc , Providingandfixingcanalinformationboardof 1.2X0.75Mpreparedon16gaugem.S.Sheet Withangleironframeofsize35x35x3mmwith Cross Bracing Of Size 25X25x3 Mm Including Paintingwithonecoatofzincchromatestoring Primerandtwocoatseachofgreen / Whiteback Ground And Back Side Grey Store Enameled Bonded With Red Retro Reflective Sheet Engineering Grade, Border / Letters / Numeral / Arrowscoatedwithnon-Pealablecrystalclear Protectivetransparentcoatretaining100% Reflectionincludingtwoangleironpostofsize 50X50x5mmof3.65Mlonginflatedatbottom Drilledontopandpaintedinwhiteandblack Bonds Of 30 Cm With Four Numbers High Strength Ofg.I.Boltsandnutsofsize10mmdia.And20 Mmlongsheetandangleironpostinonepiece Without Joints Including All Taxes, Conveying, Fixing In Ground With Cement Concrete In M-15 Block Of Size 60X60x75 Cm As Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
22.
Housing Urban and Rular Development #10370604 Price Bid
Tender For Miscellaneous Work In Govt. Ornate Garden At Aliganj, Lucknow COST OF PATHWAY TRACKING COST OF CHAIN LINK FANCING COST OF MS GATE (2 Nos) COST OF BOUNDARY WALL COST OF SUBMERSIBLE PUMP Pathway - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains. (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kind of Soil Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in: Cement mortar 1:6 (1 cement: 6 coarse sand) Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (2)With material conforming to Grade-ll (size range 53 mm to 0.075 mm) having CBR Value-25). Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All work up to plinth level: 1:4:8 (1 Cement: 4 coarse sand (zone-III) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources) Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 12 mm cement plaster of mix: 1:6 (1 cement: 6 coarse sand) Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm) Chainlink – Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement, Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade Earth excavation work for foundation upto 1.50 mtr. Depth and 30 mtr. lead complete. Providing and laying of PCC 1:4:8 grade in foundation & pilnth with proper compecting. RCC work with cement approved coarse sand and 2cm gauge approved stone ballast in proportion 1:1%:3 in lintals of door and windows, excluding its fixing and binding of steel and including necessary centering & shuttering etc. and also i/c S/o material required for proper completion of work. Binding wire to be supplied by the contractor free of cost. (In Column) Support GATE 3.00X3.00M (2 Nos) Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. all kind of soil Providing and laying of PCC 1:4:8 grade in foundation & pilnth with proper compecting. Providing and laying in position specified grade of reinforced cement concrete, including the cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement: 154 coarse sand (zone-ill): 3 graded stone aggregate 20 mm Upto Plinth Beam in footing in Column upto plinth Above Plinth Beam a) in Column Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete Columns, Pillars, Piers, Abutments, Posts and Struts Providing & Laying of steel reinforcement i/c cutting, bending, placing and binding with wire complete 12 mm cement plaster of mix: 1:6 (1 cement: 6 fine sand FM not less then 1.25) Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm) Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture Manufacturing, supplying and fixing retro reflective overhead signage boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity and encapsulated lens type heat activated retro reflective sheeting conforming to type - III of ASTM-D-4956-01 as approved by Engineer-in- charge, letters, borders etc. as per IRC: 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II of ASTM-D-4956-01 and fixing the same to the plate of structural frame work by means of suitable sized aluminium alloys, rivets or bolts & nuts @ 300 mm centre to centre all along the periphery as well as in two vertical rows along with theft resistant measures, including the cost of painting with two or more coats of epoxy paint in grey colour on the back side of aluminium shee including appropriate priming coat. The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer- incharge. (Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only shall be measured for payment), BOUNDARY WALL: Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50m lead as per direction of engg-in-charge. in Cement Dismantling steel work manually/by mechanically means in built up sections without dismembering and stacking within 50m lead as per direction of engineer in charge. Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement: 6 coarse sand) Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. cement mortar 1:4 (1 cement: 4 coarse sand) Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 12 mm cement plaster of mix: 1:4 (1 cement: 4 coarse sand) 15 mm cement plaster on rough side of single or half brick wall of mix 1:4 (1) cement: 4 coarse sand) Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with dash fastener or with fixing clips or with bolts and nuts as required including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 Itr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 kg/10 sqm) Painting with synthetic enamel paint of approved brand and manufacture to give lan even shade: Two or more coats on new work Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length (total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.1. clips to retain horizontal, including necessary bolts or 6 nos of G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in- charge, with reinforced barbed tape(R.B.T.)/Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (cost of M.S. Jangle, C.C. blocks shall be paid separately) TOTAL COST OF BOUNDARY REPAIRING WORK Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part 1), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre below ground level. 300 mm dia Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to 15: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in- charge. 100 mm nominal size dia Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm Nominal Size dia Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in- charge. Development of tube well in accordance with IS: 2800 (part 1) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, l/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in- charge. Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 100 mm Dia Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part 1), including necessary bolts & nuts of required size complete. 100 mm clamp Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per 15:2800 (part 1). 100 mm Dia Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm nominal size dia Electric logging of bore hole Supply and Installation of 1.5 HP Submersible pump set complete
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 9
Uttar Pradesh View Result →
23.
Defence #10335556 Price Bid
Tender For Repair/Replacement Of Street Lights And Other E/M Works At Mes Installation And Other Otm Buildings At Mil Station Kanasar.; 1 Taking down carefully existing unserviceable/perished surface conduit/concealed conduit/batten/casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators, wooden boxes, MS sunken boxes, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed. 2 M&L for point wiring concealed type with PVC insulated (unsheathed ) cable 1.5 Sq mm (Nominal area) multi stranded FRLS copper conductor 1100 V grade & continuous earth wire PVC insulated 1.5 Sq mm copper solid conductor connecting to common earth in and existing PVC conduit, and sunken boxes but fixing new 3mm thick plastic laminated sheet top cover,sheet screws andafter removing old unserviceable plastic laminated sheet (including cutting chases & making good the disturbed surface) complete all as specified and directed by Engineer-in-Chargefor the following:- Note :- The cost of bakellite sheet is included in the quoted rate 3 Dittoall as per item No 2.00 hereinbefore,but for one light /fan/ buzzer point controlled by one 5 Amp switch one way complete all as specified and directed by Engineer-in-Charge. 4 All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed by Engineer-in-Charge. 5 All as per serial item No. 2.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed by Engineer-in-Charge. 6 All as per serial item No. 2.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed by Engineer-in-Charge. 7 Material and labour for point wiring complete with 1.5 sqmm(nominal core) PVC insulated unsheathed 1100 volts grade cable multi stranded copper conductor FRLS single core in PVC casing caping of suitable size complete with sunk pressed steel terminel box for fitting /mounting switches / sockets regulators etc with bakelite sheet 3mm thick cover and with 1.5 sqmm PVC insulated copper conductor earth wire and connecting to earth dolly for one light / fan point controlled by one switch complete all as specified and directed by Engineer-in-Charge. 8 Dittoall as per item No 7.00 hereinbefore,but for one light /fan/ buzzer point controlled by one 5 Amp switch one way complete all as specified and directed by Engineer-in-Charge. 9 All as per serial item No. 7.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board with other switches complete all as specified and directed by Engineer-in-Charge. 10 All as per serial item No. 7.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on independent board complete all as specified and directed by Engineer-in-Charge. 11 All as per serial item No. 7.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 2.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed by Engineer-in-Charge. 12 S&F switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed. 13 S&F socket outlet, 5 pin, 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed. 14 S&F switch socket combination, 5 in 1, 5/6 Amps, flush type, 230 Volts, ISI marked, complete with junction box all as specified and as directed. 15 S&F switch socket combination, 5 in 1, 15/ 16 Amps, flush type, 230 Volts, ISI marked, complete with junction box all as specified and as directed. 16 S&F in repair electronic fan regulator, flush type, stepped type with 4 step control, 230 Volts,including making hole in sheet top cover and connecting up, ISI marked, complete all as specified and as directed. 17 S&F in repair switch piano, flush type, single pole, one way, 5/6 Amp, 230 Volts, ISI marked, complete all as specified and as directed. 18 S&F in repair switch piano, flush type, single pole, one way, 15/16 Amp, 230 Volts, ISI marked, complete all as specified and as directed. 19 S&F in repair socket outlet, 5 pin, 5/6 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed. 20 S&F in repair socket outlet universal type, 6 pin, 15/16 Amp, flush type, 230 Volts, ISI marked, complete all as specified and as directed. 21 Supply & fix in replacemet sheet metal enclosure double door powder coated forMCB DB SPN 4 way with Din rail and busbar complete all as specified. 22 Supply & fix in replacemet sheet metal enclosure double door powder coated forMCB DB SPN 8 way with Din rail and busbar complete all as specified. 23 Supply & fix in replacemet sheet metal enclosure double door powder coated forMCB DB SPN 12 way with Din rail and busbar complete all as specified. 24 Supply & fix in replacemet MCB SP 240V ,6 to 32 Amps, 10 KA, C curve rating ISI marked and connecting complete all as specified. 25 Supply & fix in replacemet MCB SPN 240V,32 Amps, 10 KA, C curve rating ISI marked and connecting complete all as specified. 26 Supply & fix in replacemet MCB TPN 415 V, 63 Amps ,10 KA, C curve rating ISI marked and connecting complete all as specified. 27 Supply & fix in replacement self ballasted LED batten Extruded PVC body with PC diffuser, fin and groove shap base for batter heat dissipation4 feet 20 wattto be install at any height on wall / ceilinghaving power factor more than 0.90 , rated voltage AC 220-240 Volt, 50 Hz, cool white 6500K colour temperatur, CRI > 80complete all as specified and directed by Engineer-in-Charge. 28 S&F in replacement self ballasted LED batten, extruded PVC body with PC diffuser fin and groove shape base for batter heat dissipation 2 feet 10 watt to be install at any height on wall/ceiling having power factor more than 0.90, rated voltage AC 220-240 Volt, 50 Hz , cool white 6500K color temperature, CRI>80 etc complete all as specified and directed by Engineer-in-Charge. 29 Supply and fix in replacemnt LED Bulb230V AC09 watt cool day light 6500Kheavy duty complere in wall lights as per existing all as specified and directed by Engineer-in -charge. 30 Supply and fix in replacemnt LED Bulb230V AC15 watt cool day light 6500Kheavy duty complere in wall lights as per existing all as specified and directed by Engineer-in -charge. 31 Supply and Fixing in replacement security lights LED 30 W Energy saving & Environmental friendly long life versatile pressure die cast aluminium IP 65, CRI>80, PF >0.90 LED Wall mounted Light Luminaries are made of die casted aluminium body and toughened glass cover for uniform light spread including bracket made out of suitable size ofGI medium grade tubing and fixed with clamps nuts and bolts, washer ccomplete all as specified and directed by Engineer-in-Charge. Make- Havells Cat No LHEXAYP7PN6K030 or equivalant inBajaj ,Crompton, Phillips and Syska 32 Material and labour for dismantling old earthingand supply, installation and testing earthing complete with galvanisedsteel earth plate electrode of size 60 cm×60 cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including galvanised iron earth lead wire 4.0 mm dia by means ofGI bolts/nuts/washers, protected by 15 mm boreGI medium grade pipe.Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C-2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work , all as specified and shown in electrical plate No 3 of MES Schd Part-I. Notes :-(i) PCC Chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting maner.(ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. 33 Supply and fix in replacement fully diffused recessed mounted 2 X 2 LED luminaire, 36 Watt Environmental friendly, new generation,aesthetically designed, white powder coated CRCA housing ultra modern recess mounting luminaire with high translucent frosted diffuser, having efficency upto 100 Lumens/watt, rated voltage 240 Volt, frequency 50 Hz, PF > 0.95, THD < 10% , CRI > 80 suitable for indoor spaces complete all as specified and directed by Engineer-in-Charge.Make:- Havells Cat Part No- LHEBAEP7IW1W036 or equivalent of Bajaj, Havells, Philips and Syska 34 Supply & installation of Smart Integrated All in one Solar Street Light with Built in Mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4 ) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500K having capacity 20 Watt ,IP 65, 120 lumens/watt , min18 AH lithium ferrous phopshate battery, LED life 50000 hours including bracket made out of suitable size ofGI medium grade tubing and fixed with clamps nuts and bolts, washer , Suitablelength MS tubular pole medium grade with painting as per manufacturer recommendation , testing & commissioning complete including taking down old lighting system all as directed by Engineer-in-Charge.Note :-(i) Contractor has to furnish a replacement warranty of 05 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced free of cost in the following case :-(a) Manufacturing defects.(b) Failure due to mechanical and electrical impact.(c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries. 35 M & LPCC (1:3:6) type C-2 using 40 mm graded crushed stone aggregate as in foundation of poles/ struts etc as filling & mass concrete complete all as specified and directed by Engineer-in-Charge. 36 M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping including form work complete all as specified and directed by Engineer-in-Charge. 37 M & L for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundation etc as filling & mass concrete complete all as specified and directed by Engineer-in-Charge. 38 Material and labour for dismantling old earthing of any type. Supply, installation, testing of advanced maintenance free environment friendly CPRI approved earthing 10 feet long 17 mm dia earth electrode made high tensile low carbon steel circular rods, molecular bonded copper on outer surface (minimum copper bonded thickness 250 micron) with terminal to connect incoming copper strip 25 x 3 mm earthing strips with the equipment/machinery of desired length as per site requirement with 02 bags (25 Kg each) of environment friendly backfill compound with ROHS test certificate for each. The remaining space will be filled with soil and top of earth pit covered with high density polymer.Earth pit chamber cover of dimension (300 mm x 300 mm x 214 mm) with locking seal as to achieve the desired ohmic value complete all as specified and directed.Note : (i) Payment will be released only after the resistance value achieved less than 1 ohm. If value of resistance found more than 1 ohm contractor will do the fresh earthing without any extra cost.(ii) Rate of Copper strip 25x3 mm from earthing terminal to equipment/machinery with suitable size nuts/bolts and washers is deemed to be included in rate quoted by tendrer. 39 Supply and fix in replacement fully diffused recessed mounted 1 X 1 LED luminaire, 36 Watt Environmental friendly, new generation,aesthetically designed, white powder coated CRCA housing ultra modern recess mounting luminaire with high translucent frosted diffuser, having efficency upto 100 Lumens/watt, rated voltage 240 Volt, frequency 50 Hz, PF > 0.95, THD < 10% , CRI > 80 suitable for indoor spaces complete all as specified and directed by Engineer-in-Charge.Make:- Havells Cat Part No- LHEBAEP7IW1W036 or equivalent of Bajaj, Havells, Philips and Syska 40 Material and labour for dismantling old earthingand Supply , installation and testing earthing complete with galvanised iron earth plate electrode of size 60 cm×60 cm.× 6mm thick, buried directly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to and including GI Strip 32 x 6 mm (upto the body of equipment) by means ofGI bolts/nuts/washers, protected by 40 mm boreGI medium grade pipe.Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, RCC cover & frame, PCC (1:3:6) type C-2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation and earth work , all as specified and shown in electrical plate No 3 of MES Schedule Part-I complete all as specified and directed by Engineer-in-Charge. Notes :-(i) PCC Chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting maner.(ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. 41 Supply and fix in replacement 03 core PVC insulated multi stranded copper conductor cable (flexible) of size 1.5 sqmm, 1100 Volts grade, ISI marked (IS-694), laid in duct / tray / wall / ceiling with the help of steel clamps including cable glands with rubber cover etc complete all as specified & as directed. Note:-T&P required such as ladder/manpower etc are rnclusive in rate quoted.Nothing extra shall be admissible on this account 42 S & F in replacement PVC non modular MCB boxsuitable for MCB 6 to 32 Amp complete all as specified and directed by Engineer-in-Charge. Note :-(i) MCB will be measured and paid separately under respective item. 43 S &F electric shock treatment chart printed on A0 size paper duly plastic laminated and fixed inside a wooden/PVC photo frame of 50 mm width with 3 mm sheet glass and 6 mm plybood backing and suitable hanging arrangement to wall with hooks/steel chain etc, including taking down old U/S one complete all as specified and directed by Engineer-in-charge. 44 S &F First aid chart printed on A0 size paper duly plastic laminated and fixed inside a wooden/PVC photo frame of 50 mm width with 3 mm sheet glass and 6 mm plywood backing and suitable hanging arrangement to wall with hooks/steel chain etc, including taking down old U/S one complete all as specified and directed by Engineer-in-charge. 45 Supply and laying in replacement LT rubber mating chequered type of size 2 mtr x 1 mtr x 12 mm thick as per IS 5424/1969 complete all as specified and directed by Engineer-in-Charge. 46 Supply & fix in replacement switch socket combination box multi purpose with complete PVC board 5 pin 5 Amps flush type including 1.5 sqmm x 3 core multistranded copper wire of minimum 2 meter complete all as specified and directed by Engineer-in-Charge. 47 Supply & fix in replacementswitch socket combination box multi purpose with complete PVC board 3 pin 15 Amps and 3 pin 5 Amps flush type multipurpose 2 in one including 2.5 sqmm x 3 core multistranded copper wire of minimum 2meter as desired complete all as specified and directed by Engineer-in-Charge.
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
24.
Tourism #10301450 AOC
Tender For Civil Works , Clearing Grass And Removal Of Rubbish Upto A Distance Of 50 M Outside The Periphery Of The Area , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. All Kinds Of Soil , Refilling The Pipeline/Foundation Trenches Plinth Sides, Foundation Etc. With Available Excavated Earth In Layers Not Exceeding 20 Cm Depth Consolidating Each Layer Ramming And Watering Lead Upto 50 M And All Lifts And Disposal Of Surplus Earth As Directed By Engineer In Charge. , Carriage Of Debris From The Site Of Work Like Excavated Earth,Demolished Stones, Rock Boulders,Vegetation Etc, And Disposing The Same To A Distance Of 1.00Kms.Including All Lead And Lifts Etc. Complete By Means Of Tipper Truck( Contractor To Indentify The Site Of Disposal At His Own Cost And Risk). , Brick Work Using Common Burnt Building Bricks In Cement Mortar 1:3 (1 Cement : 3 Coarse Sand) With Bricks Of Class Designation 75 Kg/ Cm2 (Wire Cut Bricks). In Superstructure Upto Floor Five Level. , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , Exposed Decorative Laterite Masonary Of Stones As Specified And Laid As Directed By Architect In Cement Mortar 1: 4 (1Cement: 4 Coarse Sand ) , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) Above Plinth Upto Level V. , Providing And Laying In Position Cement Concrete 1:2:4 (1 Cement : 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggregate 40 M Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing .All Works Upto Plinth Level , Providing & Laying Cement Concrete 1:3:6 (1 Cement: 3 Coarse Sand: 6 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In:All Works Upto Plinth Level , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) All Works Upto Plinth Level , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) ..In Walls (Any Thickness), Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Structs Etc. Upto Floor Five Level , Providing And Laying In Position (1:11/2:3) Reinforced Cement Conrete Excluding The Cost Of Centering, Shuttering, Finishing And Reinfrocement (1 Cement: 1½ Coarse Sand:3 Graded Stone Agg 20Mm Nominal Size) ..In Beams, Suspended Floors, Roofs Having Slope Upto 15° Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases Upto Floor Five Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Foundations, Footings, Bases For Columns , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Columns, Piers, Pillars, Aburments, Posts And Struts (Square Rectangle Polygon In Plan) , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For :Sides And Soffits Of Beams, Beam Haunchings, Cantilever, Girders, Bressumers And Lintels Plinth Beams Not Exceeding 1M In Depth , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For Sloping Or Battering Surface (Slabs, Beams, Louvers, Etc) Including Folded Plates I) Where Inclination To The Horizontal Does Not Exceed 30° Requiring Shuttering On The Underside Only + Extra To Be Added For Additional Height In Centering, Shuttering Where Ever Required With Adequate Bracing, Propping Etc. Including Cost Of De- Shuttering And De-Centering At All Levels, Over A Height Of 3.5M, For Every Additional Height Of 1M Or Part Thereof. (Plan Area To Be Measured) Suspended Floors, Roofs, Landings, Beams And Balconies (Plan Area To Be Measured) Where Inclination To The Horizontal Exceeds 30° Requiring Shuttering On The Underside & Upperside If Required (Only Area Of Underside Shall Be Measured For Payment) , Providing Tmt Steel Reinforcement Bars Of (Sail, Tata. Vizag, Jsw Steel Ltd.) )(Confirming To Is 1786 Of 1986) For Reinforced Cement Concrete Work (Conforming To I.S. 1786 Of 1986) Including Bending, Binding & Placing In Position In All The Floors Along With The Factory Made Precast Concrete Cover Blocks Of Specified Sizes Whose Compressive Strength Is Not Less Than That Of Surrounding Concrete In The Structural Member. , Providing Woodwork In Frames Of Doors, Windows, Clerestory Windows Trusses & Other Frames Wrought Framed And Fixed In Positon.:Second Class Indian Teak Wood , Providing And Fixing 38 Mm Thick Panelled Glazed Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Window Including Black Enamelled Iron Butt Hinges With Necessary Screws: Second Class Indian Teak Wood , Providing And Fixing Louvers 50 Mm Wide In Grooves In Clerestory Window Frames Excluding The Cost Of Frames.:Second Class Indian Teak Wood 12 Mm Thick , Providing Flat Iron Hold Fast 40 Cm Including Fixing To Frame With 10 Mm Dia Bolts, Nuts And Wooden Plugs And Embeded In Cement Concrete Block 30 X 10 X 15 Cm 1:3:6 Mix (1 Cement: 3 Coarse Sand: 6 Stone Aggregate 20 Mm Nominal Size.: 40 X 3 Mm Flat Iron Hold Fast, 15 Cm Long , Providing And Fixing M.S. Grill Of Required Pattern In Wooden Frames Of Windows Etc. With M.S. Flats Square Or Round Bars With Round Headed Bolts And Nuts Or By By Screws.:Plain Grill , Providing And Fixing Bright Finished Brass Butt Hinges With Necessary Screws Etc Complete: 125 X 70 X 4 Mm (Ordinary Type) , Providing And Fixing Bright Finished Brass Tower Bolts (Barrel Type) With Screws Etc. Complete: 200 X 10 Mm , Providing And Fixing Bright Finished Brass Handles With Necessary Screws Etc Complete: 125Mm , Providing And Fixing Bright Finished Brass Door Latch With Necessary Screws Etc Complete:250 X 16 X 5 Mm , Providing & Fixing Bright Finished Brass 100 Mm. Mortice Latch & Lock & A Pair Of Levers, Handles With Necessary Screws Etc. Complete (Indian Make Of Approved Quality). , Providing And Fixing 150 Mm. Bright Finished Brass Floor Door Stopper With Rubber Cushion Screws Etc. To Suit Shutter Thickness Complete. , Providing And Fixing Brass Hydraulic Door Closer Of Make Everest Universal 68 Or Equivalent With Necessary Screws And Fittings Complete. , Providing And Fixing Factory Made Panelled Door Shutter Fabricated Out Of Second Class Teak Wood With Styles Top And Middle Rail, Lock And Bottom Rail With Navopan Or Equivalent Weather Resistant Melamine Faced Prelaminated Twin Particle Board - Bonded With Bwp/Bwr Exterior Grade Synthetic Resin As Per Is - 3087 (1985)Type I Including Anodised Aluminium Butt Hinges With Necessary Screws Etc. Complete.: 12 Mm Thick Panel (Iii) 30 Mm Thick , Providing And Fixing Flush Door Shutter Of Solid Core Melamine Face Three Layered, Prelaminated Wood Based Particle Board Exterior Grade Having Shade Of Choice On Both Sides (Ptx) Or Having Shade Of Choice On One Side And Balancing Lamination On The Other Side (Plx) As Per Is 3087 (1985) Type I On The Edge Of Novopan Or Equivalent Bonded With Bwr/Bwp Synthetic Resin With Second Class Teak Wood, Lipping Of Section Of Size 12 Mm X 30 Mm Flange And 18 Mm X 10 Mm Web (18 Mm Deep) Fixed Into 18 X 10 Mm Groves Of Shutter With Water Resistant Adhesive And Fully Threaded G.I. Screws 50 Mm Not More Than 450 Mm Centre To Centre Including Anodized Aluminium Butt Hinges With Necessary Screws Etc. Complete.:Natural Teak On Both Faces:2) 30Mm Thick , Frp (Fiber Reinforced Polymer) Frames With Wood Finish Manufacture, Supply And Installation (With Anchor Fastener) Of Epee Or Equivalent Goan Make Frp (Fiber Reinforced Polymer) Frame Of Cross Section As Per Options Below With Right Angle Joint And Frp (Fiber Reinforced Polymer) Laminate Made From 450 Grams Per Sq.Mts (Gsm) Chop Strand Glass Fiber (Matt) And Unsaturated Polyester Resin With Viscosity Range Of 400/450 Centipoises Per Second (Cps). The Core Of Frame Would Be Filled With Seasoned Wood As Infill Material. The Slot Of Frame For Door Resting Will Be Of Suitable Width So As To Take Specified Thickness Door. The Frame Will Be Water Proof As Well As Mild Acid/ Alkali Resistant Manufactured In An Iso 9001- 2015 Certified Company. Accessories:I) S. S. Hinges 4 - 3 Nos Ii) S. S. Latch - 1 No Iii) Tower Bolt 5 - 2 Nos Iv) Handle 5 - 2 Nos Shutter Thickness: A) 30Mm , Providing And Fixing Anodized Aluminium Shutters In Accordance With The Specification Annexed With Goa Schedule Of Rates (2004) Vol & Ii Including All Taxes, Transportation, Scaffolding And Handling Etc. Complete As Per Direction Of The Engineer-In-Charge: Windows With Two Sliding Shutters Using 18 Mm Series Shutters Section.:Figured Glass , Providing And Fixing Anodized Aluminium Shutters In Accordance With The Specification Annexed With Goa Schedule Of Rates (2004) Vol & Ii Including All Taxes, Transportation, Scaffolding And Handling Etc. Complete As Per Direction Of The Engineer-In-Charge: Adjustable Louvered Windows.:Plain Glass , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Providing And Fixing Stainless Steel (Grade 304) Railing Made Of Hollow Tubes, Channels, Plates Etc.With Hairline Finish, Including Welding, Grinding, Buffing, Polishing And Making Curvature (Wherever Required) And Fitting The Same With Necessary Stainless Steel Nuts And Bolts Complete, I/C Fixing The Railing With Necessary Accessories & Stainless Steel Dash Fasteners, Stainless Steel Bolts Etc., Of Required Size, On The Top Of The Floor Or The Side Of Waist Slab With Suitable Arrangement As Per Approval Of Engineer, ( For Payment Purpose Only Weight Of Stainless Steel Members Shall Be Considered Excluding Fixing Accessories Such As Nuts, Bolts, Fasteners Etc.). , Kotah Stone Slab Flooring Over 20 Mm (Average) Thick Base Laid Over & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Complete With Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand): 20 Mm Thick. , Kotah Stone Slab Flooring Over 25 Mm Thick In Risers Of Steps, Skirtings, Dado & Pillars Laid On 12Mm (Average) Thick Cement Mortor 1:3 (1 Cement : 3 Coarse Sand) & Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing & Polishing Complete. , Providing And Laying Jet Black Mirror Polish Granite Flooring And Dado Over 20Mm Thick Base Of Cement Mortar 1:4 Laid Over And Jointed With Cement Slurry Including Rubbling Complete Granitic Slab (Jet Blck With Mirror Polish) 20 Mm Thick Add Q0% Wastage 1.00 , Providing 25 Mm Thick Cuddapah Slabs Machine Cut And Polished On Either Side In Partitions Including Making Necessary Grooves In The Wall And Fixing With Cement Mortar, Complete As Directed By The Engineer-In-Charge , Providing And And Laying Vitrified Floor Tiles In Different Sizes Of Johnson, Somany, Kajaria (Thickness To Be Specified By The Manufacturer) With Water Absorption Less Than 0.08% And Conforming To Is:15622 Of Approved Make In Colours And Shades As Specified Laid On 20 Mm Thick Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Including Grouting The Joints With White Cement And Matching Pigment Etc., Complete :600X 600 Mm Light Shades , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.:60 Mm Thick In All Colours Except Grey (M35 Grade) , Providing And Laying Factory Made Shot Blasted Cement Concrete Interlocking Paver Block Of Minimum M35/M40 Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Aprpoved Size And Design / Shape Laid In 50 Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand, Etc. All Complete As Per The Direction Of Engineer.- In I, Wave, Rectangular, Square Etc. Shapes. The Products Should Comply To Is 15658:2006 And Manfucatured By Iso9001: 2008 Certified Plant. The Shot Blasting Should Be Done Using 0.4-0.5Mm Dia Steel Shots With A Speed Of 3200 Rpm.:60 Mm Thick In Grey Colour (M35 Grade) , Providing And Laying Flamed Finish Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm (Average) Thick Base Of Cement Mortar 1:4 (1 Cement : 4 Coarse Sand) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer : Flamed Finish Granite Stone Slab. Elite Brown , Providing And Fixing 18 Mm Thick Gang Saw Cut,Mirror Polished, Premoulded And Prepolished,Counters, Window Sills, Facias And Similar Locations Of Required Size, Approved Shade,Colour And Texture Laid Over 20 Mm Thick Base Cement Mortar 1:4 (1 Cement : 4 Coarse Sand),Joints Treated With White Cement, Mixed With Matching Pigment, Epoxy Touch Ups, Including Rubbing, Curing, Moulding And Polishing To Edges To Give High Gloss Finish Etc. Complete At All Levels. Granite Of Any Colour And Shade, Area Of Slab Over 0.50 Sqm:Cherry Red , Providing And Fixing Colour Coated Galvulium Roofing Sheets Of 0.5Mm Thickness Including All The Accessories (Tata Make) But Excluding The Cost Of Purlins, Rafters, Trusses, Flashings Etc. Complete As Per The Directions Of The Engineer In Charge. , Add For Providing & Fixing Flashings -[Corners, Ridges, Valleys, Gable End & Trims] (Girth Upto 610Mm) Including All The Accessories Complete As Per The Directions Of The Engineer In Charge. , Providing And Fixing Prince Or Equivalent Make Pvc Swr Half Round Eaves Gutter With Bolts, Nuts And Flat Iron Brackets 40 X 3 Mm Size Complete.-180 Mm Nominal Size , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Joint Bracket With 2 Clamps For Socketed Half Round Eaves Gutters.:180 Mm Nominal Size , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr 90 Deg. Elbow With/Without Outlet With 2 Clamps For Socketed Half Round Eaves Gutters.:180 Mm Nominal Size , Extra For Providing And Fixing Prince Or Equivalent Make Pvc Swr Short Stop Ends For Socketed Half Round Eaves Gutters.:180 Mm Nominal Size , Providing Water Proofing Treatment Over The New Reinforced Cement Concrete Roofs Terrace Toilet By Spreading Cement Slurry Over The Reinforced Cement Concrete Slab And Laying Of 10Cms. Average Laterite Stone Ballast Coba With The Necessary Gradient For Easy Flow Of Rain Water And The Coba In Covered With Damp Proof Of Hindustan Water Proofing Co. Or Equivalent Jointless Water Proofing Plaster Of Mix 1:3 ( 1 Cement : 3 Find Sand), Finished Smooth With Wooden Trowel With False Marking Of 30 Cms Square. The Vertical Surface Of The Adjoining Walls Are To Be Treated Upto A Height Of 30Cms Including Rounding Of Junction (The Rate Includes For Complete Items Including Labour And Materials And Including Cost Of Initial Treatment Of Roof Slab As Follows. The Injunction Of Damp Proof Or Equivalent Compound With Cement Solution Will Be Given As And When Found Necessary For Filling Honey Comb, Cracks Etc. In The Reinforced Cement Concrete Slabs). Note: Cement Consumption 25 Kg/Sq.M. , Providing & Fixing Of Metal Tile Ceiling System Comprising Of Tile Of 600Mm Wide And 600Mm Long Manufactured Of 0.6Mm Thick Aluminium Clip-In Perforated 2.5Mm Dia 5.5Mm C/C. The Tile Shall Be Manufactured On Advanced Equipment, Which Includes Several Levelling Stages In The Manufacturing Process. Tile Ends Shall Be Raised With Pips And Stops To Ensure Positive Engagement Into The Spring To Enable For De-Mounting Of Individual Panels. The Tile Sides Shall Be Sufficiently High To Ensure A Minimum Deflection Across The Length Of Tile. All Tiles Shall Be Bevelled Edged. The Tile Shall Be Polyester Based, Powder Coated In White Colour. Tile Shall Be Clipped Into Clip In Profile Of 0.5Mm Thick G.I. The Clip In Profile Shall Be Supported From Slab By Means Of Rigid Suspension Of 4Mm G.I. Rod, Hold On Clamp With Clip. Acoustic Felt: Non-Woven Felt Made Of Glass-Reinforced Fibreglued Over The Perforation For Sound Absorption. , 12Mm Cement Plaster 1:4 (1 Cement : 4 Fine Sand) , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , 20Mm Cement Plaster 1: 3 (1 Cement : 3 Fine Sand) , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) , Neat Cement Punning , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) Extra For Plastering Spherical Ceiling , 20Mm Cement Plaster 1: 3 (1 Cement : 3 Fine Sand) Extra For Providing And Mixing Water Proofing Material Proportion Recommended By The Manufacturers. , 6Mm Cement Plaster To Ceiling 1: 3 (1 Cement : 3 Fine Sand) Extra For Plastering Done On Mouldings, Cornices, Or Arch It Raves Including Neat Finish To Line And Level.In One Coat , 12Mm Thick Moulded Cement Mortar Bands In Cement Mortar 1:4 (1 Cement : 4 Fine Sand) Cm Per Meter , Painting One/ Two More Coats With Ordinary Ready Mixed Paint Of Approved Brand & Manufacture In All Shades Except White Or Green On Old Work To Give An Even Shade. , Painting Two Or More Coats (Excluding Priming Coat) With Superior Quality Ready Mixed Paint For Steel Work Of Approved Brand & Manufacture In All Shades On New Work To Give An Even Shade. , Painting (Two Or More Coats) With Synthetic Enamel Paint Of Approved Brand And Manufacture In All Shade Or New Work Over And Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture To Give An Even Shade , Wall Painting (Two Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On New Work To Give An Even Shade. , Wall Painting (One Or More Coats) With Plastic Emulsion Paint Of Approved Brand And Manufacture On Old Work To Give An Even Shade. , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture(Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Painting One Or More Coats Of Acryllic Exterior Paint Of Approved Brand And Manufacture(Such As Dulex/ Asian Paints/ Sherwin Willians) On Old Work Including Cleaning The Surface With Water Etc. Complete. , Providing And Applying White Cement Based Putty Of Average Thickness 1.00Mm Of Approved Brand And Manufacturer, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. , Demolishing Laterite Stone Masonry In Cement Mortar Including Stacking Of Serviceable Material & Disposal Of Unserviceable Material Within 50 Mts. Lead. , Dismantling Steelwork In Built Up Sections In Angles, Tees, Flats And Channels Including All Gusset Plates Bolts, Nuts, Cutting Dismembering And Staking Within 50 Mts. Lead , Dismantling G.I. Sheets Roofing Including Ridges, Hips Valleys And Gutters Etc. And Stacking The Material Within 50 Meters Lead. , Providing And Fixing Weepholes With Rigid Pvc Make Laid In Position With A Required Slope And Level While Layingpipes Of Approved The Concrete Of Retaining Wall,Wing Wall And Earth Retainig Structure Complete As Directed By The Engineer In Charge:110 Mm Dia , Supplying And Stacking Of Good Earth At Site Including Royalty And Carriage Upto 1 Km. (Earth Measured In Stacks Will Be Reduced By 20% For Payment). , Spreading Of Sludge, Dung Manure Or/And Good Earth In Required Thickness (Cost Of Sludge, Dung Manure Or/And Good Earth To Be Paid Separately). , 1) Grassing With Doob Grass Including Watering And Maintenance Of The Lawn For 30 Days Or More Till The Grass Forms Of Thick Lawn Free From Weeds And Fit For Moving, Including Supplying Good Earth If Needed. (Cost Of Doob Grass Not Included ) 2) In Rows 15 Cm Apart In Either Direction. , Digging Holes In Ordinary Soil And Refilling The Same With The Excavated Earth Mixed With Manure Or Sludge In Ratio Of 2: 1 By Volume (2 Parts Or Stacked Volume Of Earth After Reduction By 20% And 1 Part Of Stacked Volume Of Manure After Reduction By 40%) Flooding With Water, Dressing Including Removal Of Rubbish & Surplus Earth If Any With All Leads & Lifts (Cost Of Manure Or Sludge Of Extra Good Earth If Needed To Be Paid For Separately) Holes 1.2M Dia And 1.2M Deep , Providing And Fixing M.S. Flat Iron Tree Guard 60Cm Dia & 2 M High Above Ground Level, Formed Of 4 Nos. 25 X 6Mm And 8 Nos. 25 X 3Mm Vertical M.S. Flat Iron Rings In Two Halves, Bolted Together With 8Mm Dia And 30 Mm Long Bolts Including Painting Two Coats With Paint Of Approved Brand And Manufacture Over A Coat Of Priming, Complete In All Respects. , Proving And Fixing White Vitreous China Water Closet Squating (European Type W.C. Pan) With Seat And Lid, C.P. Brass Hinges And Rubber Buffers 10 Lts. High Level P.V.C.. Flushing Cistern (Of Approved Make ) With Fittings, Rack Bolts 32 Mm Diameter P.V.C. Telescopic Flush Pipe With Fit Tings And Clamps 25Mm P.V.C.. Over Flow Pipe With Specials & Mosquito Proof Coupling Of Approved Municipal Design And Nylon. Chain And Pull Complete, Cutting And Making Good The Walls Ad Floors Where Required.:W.C. Pan With White Plastic Seat And Lid. , Providing And Fixing Vitreous China Wash Basin With R Sor C.I.Brackets Painted White,15Mm C.P. Brass Pillar Taps C.P. Brass Chain With Rubber Plug 32 Mm C.P. Brass Waste Of Pattern, 32 Mm Diameter M.I. Or C.P. Brass Trap And Union Complete, Including Cutting And Making Good The Walls Where Required.:Flat Back Wash Basin Size 550 X 400Mm With A Single 15 Mm C.P. Brass Pillar Taps. , Providing & Fixing (4) 100 Mm Sand Cast Iron Grating For Gully Floor Or Nahni Trap. , Providing And Fixing 600 X 450 Mm Bevelled Edge Mirror Of Superior Glass (Of Approved Quality) Complete With 6 Mm Thick Asbestos Sheet Ground Fixed To Wooden Cleats With C. P. Brass Screws And Washers. , Providing And Fixing Toilet Paper Holder :C.P. Brass , Providing & Fixing Liquid Soap Container With C.P. Brass Lid And Brackets Fixed To Wooden Cleats With C. P. Brass Screws A)Glass Container , Providing And Fixing White Vitreous China Type Water Closet Squatting Pan (European Type W.C. Pan) With Flush Valve Nelson/ Similar) Fully Chromium Plated With Stop Cock Wall Flanges Flush Pipe Or Elbow And Vaccu.M Breaker Coupling Etc. Including Cutting Making Good The Walls And Floors Where Required. , Providing And Fixing Brass Bib Cock (Heavy) Of Approved Quality :15 Mm Nominal Bore , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality : A)15 Mm Nominal Bore , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality :B)20 Mm Nominal Bore , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality : C)25 Mm Nominal Bore . , Providing And Fixing Brass Stop Cock (Heavy) Of Approved Quality :D)32 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality :A)15 Mm Nominal Bore , Providing And Fixing Brass Full Way Valve (Heavy) Duty With Wheel Of Approved Quality :B)20 Mm Nominal Bore , Providing And Fixing Ball Valve (Brass) Of Approved Quality :A) High Pressure With P.V.C. Floats: 25Mm Nominal Bore , Providing And Fixing Non-Return Valve Of Approved Quality :A)25 Mm Nominal Bore , Providing And Fixing Non-Return Valve Of Approved Quality : B)32 Mm Nominal Bore , Providing And Placing On Terrace Roof Of Floor Two (1St Flor Roof Single Piece Rotational Moulded Polythene Water Storage Tank Having I S I Mark And Conforming To I S 12701; 1996. C) 1000 Lit. Capacity , Providing And Fixing Square-Mouth S.W. Gully Trap Grade ‘A Complete With C.I. Grating Brick Masonry Chamber And Water Tight C.I. Cover With Frame Of 300 X 300 Mm Size (Inside The Weight Of Cover To Be Not Less Than 4.53 Kg). And Frame To Be Not Less Than 2.72 Kg As Per Standard Design : A)100 X 100 Mm Size P Type , Constructing Brick Masonry Manhole Or Inspection Chamber With Second Class Bricks In Cement Mortar 1:5 (1 Cement :5 Fine Sand) Reinforced Cement Concrete Top Slab With 1:2:4 Mix (1 Cement: 2 Coarse Sand;4 Graded Stone Aggregate 20Mm Nominal Size Foundation Concrete 1:2:4 Mix (1 Cement ;2 Coarse Sand :4 Graded Stone Agrregate 40Mm Nominal Size) Inside Plastering 12 Mm Thick With Cement Mortar 1:3 (1 Cement :3 Coarse Sand) Finished With A Floating Coat Of Neat Cemetn And Making Channels In Cement Concrete 1:2:4 Mix (1 Cement :2 Coarse Sand :4 Graded Stone Aggregate 20 Mm Nominal Size) Neatly Finished Complete As Per Standard Design. : D)Inside Size 60 X 60Cm And 60Cm Deep Including C.I. Cover With Frame (Light Duty) 455X610mm Internal Diameter Total Weight Of Cover And Frame To Be Not Less Than 38 Kg. (Weight Of Cover 23 Kg). , Constructing Soak Pit 1.20M X 1.20M X1.20M Filled With Laterite Stone Aggregate 125 To 180 Mm Including S.W. Drain Pipe 100 Mm Diameter And 1.2M. Long Complete As Per Standard Design. , Providing And Fixing Rigid Pvc S.W.R. (Soil, Waste & Rain Water) Drainage Pipes Of Approved Including Lubricant Etc. Complete (Single/Double) Socketed: A)110 Mm Dia , Providing And Fixing Rigid Pvc Bend Of Required Degree (Of Approved Make) For S.W.R. Drainage Pipes Of Approved Including Lubricating Etc Complete Bend With Door :A)100 Mm Dia , Providing And Fixing Single Tee Of Rigid Pvc (Approved Make) For S.W.R. Pipes Including Lubricating Etc. Complete, Without Door: A)110 Mm Dia , Providing And Fixing Single Y Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door :A)110 Mm Dia , Providing And Fixing Nahani Trap Of Rigid Pvc (Approved Make ) For S.W.R. Pipes Including Lubricating Etc Complete, Without Door 110 Dia A)110Mm Dia , Providing And Fixing R.P.V.C. Vent Cowl: A)110 Mm Dia , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bib Cock Short Body Jaquar Make Or Equivalent. Confirming To Is 8931;1993 A)15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Long Body Bib Cock With Wall Flance Jaquar Make Or Equivalent. Confirming To Is 8931;1993 A)15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Concealed Stop Cock With Slinding Flance 15 Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 A)15Mm Nominal Bore , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bottle Trap Economy Type 32Mm Jaquar Make Or Equivalent. Confirming To Is 8931;1993 , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5 Pipe). A)15 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Internal Work Exposed On Wall (Medium Duty Sdr 13.5 Pipe). B) 20 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc. A)15 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc. B)20 Mm Outer Dia Cpvc Pipe , Providing And Fixing Chlorinated Ployvinyl Chloride (Cpvc) Pipes Confirming To Is:15778, Having Thermal Stability For Hot And Cold Water Supply Including All Cpvc Plain And Brass Threaded Fittings Including Fixing The Pipes With Clamps At 1 Mt. Spacing. This Includes Jointing Of Pipes And Fittings With One Step Cpvc Solvent Cement And Testing Of Joints Complete As Per Direction Of The Engineer-In-Charge. Concealed Work (Medium Duty Sdr 13.5 Pipe) Including Cutting Chases And Making Good The Walls Etc. C)25 Mm Dia Nominal Outer Dia Pipes. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes Confirming To Is: 15778 Having Thermal Stability For Hot And Cold Water Supply Includng All Cpvc Plain And Brass Threaded Fittings Cpvc Solvent Cement, Trenching, Refilling And Testing Of Joints Complete As Per Firectionof The Engineer In Charge.(External Work (Heavy Duty Sdr 11 Pipe) C)25 Mm Nominal Outer Dia Pipes. , Providing And Fixing Chlorinated Polyvinyl Chloride (Cpvc) Pipes Confirming To Is: 15778 Having Thermal Stability For Hot And Cold Water Supply Includng All Cpvc Plain And Brass Threaded Fittings Cpvc Solvent Cement, Trenching, Refilling And Testing Of Joints Complete As Per Firectionof The Engineer In Charge.(External Work (Heavy Duty Sdr 11 Pipe) D)32 Mm Nominal Outer Dia Pipes. , Providing And Fixing Stainless Steel A Isi 304 (18/8) Kitchen Sink As Per Is 13983 Including Cutting Of Stone And Making Good The Walls Wherever Required. Kitchen Sink Without Drain Board. With Coupling & All Accessories Complete With Choke Stop Strainer, Plain Type Having Flat Borders For Correct Sandwithing Between The Plaform Top And Bottom Slabs Complete. A)Overall Size 610Mmx510mm (24X20) Bowl Size 545Mmx445mmx200mm (211/2X 17 1/2X 8) Depth 200 Mm. Glossy. 1.0Mm Thk, , Providing And Fixing Hand Shower (Health Faucet) With 8Mm Dia, Abs/Brass Body With Double Lock 1.00M Long Flexible Tube (Brass Plated Stainles Steel Flexible Hose) And Wall Hook Of Approved Quality Confirming To Is Standards. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Two Way Bib Cock With Single Knob And Wall Flange Conforming To Is 8931:1993 15Mm Nominal Bore. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement And Testing Of Joints Complete As Per Direction Of Engineer. Internal Work - Exposed On Wall. I)Sch-80(Blue)/(White) A)20Mm Outer Dia. , Providing And Fixing Astm Upvc Pipe, Conforming To Astm 2467 With Iso 14001, Including All Upvc Plain & Brass Threaded Fittings, Including Jointing Of Pipes & Fittings With One Step Upvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer. External Work. I) Sch-40(Blue)/(White) A)20Mm Outer Dia. , Providing And Fixing Nickel Chrome Plated Copper Alloy Fancy Bib Cock With Extended Lever Handle And Wall Flange Confirming To Is 8931; 1993 A)15Mm Nominal Bore , Providing Anti - Termite Treatment To Buildings Conforming To I.S.S. 6113 Part Ii 1971 (Revised) Including Adopting Precautions For Health Hazards And Safety Measures As Required Therein With The Cost Of All Materials, Chemicals, Plants, Equipments Required For The Treatment And Furnishing A Guarantee For A Minimum Period Of 10 Years From The Date Of Completion Including Eradicating Any Infestation Of Termite Free Of Cost During The Guaranty Period Complete. (Thepayment Will Be Made On Plinth Of The Building). A)Pre-Construction , Providing Anti - Termite Treatment To Buildings Conforming To I.S.S. 6113 Part Ii 1971 (Revised) Including Adopting Precautions For Health Hazards And Safety Measures As Required Therein With The Cost Of All Materials, Chemicals, Plants, Equipments Required For The Treatment And Furnishing A Guarantee For A Minimum Period Of 10 Years From The Date Of Completion Including Eradicating Any Infestation Of Termite Free Of Cost During The Guaranty Period Complete. (Thepayment Will Be Made On Plinth Of The Building). B)Post Construction , Pvc False Ceiling Grid Type : Providing And Fixing Pvc False Ceiling Consisting Of 600Mm X 600Mm, 5Mm(±0.25) Thick Plain Pvc Sheet Of 600 Kg/Cbm Density Manufactured By An Iso- 9000 Certified Company, Used As Panel Insert In A Frame Work Made Using Anodized Aluminum T- Section Of Sizes 1 X1 (25X25mm, 19 Gauge Or 1Mm Thick) In Square Pattern Of Grid Sizes Of 2X2(600X600mm). The Aluminum Frame Work Is Supported From The Ceiling With The Help Of J Hook And G.I. Wire / 6Mm M.S. Rods Of Required Sizes To Maintain Proper Level Etc. The Aluminum Framework Is Supported On Side Wall With The Use Of Aluminum L-Section Of Size 1X1 (25X25mm) Angles Etc. Complete As Per Direction Of Engineer-In-Charge, Manufacturers Specification & Drawing. , Fabrication And Fixing Of Aluminium Composite Panel Cladding With Thick 3Mm/ 0.25Mm Acp Sheets, Aluminium Framework, With 50 X 25 X1.2 Mm Thick Sections. Silicon Sealants Etc. Including Accessories Complete. , Providing And Laying Laterite Flooring 160Mm Thick With Hard Laterite Stone As Shown In The Drawings, Layed Over Bed Earth, Filling The Joints With Grass, Including As Approved By The Engineer, Etc Complete.Crushing Strength Of Patradevi/Hard Laterite Stone Not Less Than 70Kg/Sqcm , Providing And Fixing Statues (Lion Statue 3D View) Made Up Of Pop Of Size 3.45Ft X 4Ft Including All Fitting Fixtures , Finish Should Be Similar To The Photo Features References,Concepts Of Historic Eras Including All Tools, Plants, Labour And Materials, Leads, Lifts Etc Complete. As Directed By Engineer-In-Charge. , Fabricating, Providing & Fixing Signages Using 304 Grade Stainless Steel 1.5Mm Thick Brushed Steel Finish Plate With Eched Lettering . Ss Plate Of Required Size As Shown In Drawing Will Be Fixed To The Wall/ Door/Wooden Partition With Ss Studs, Complete. Refer Drawing Scspl/Diet/Sign , Supply And Installation Of Dustbin Of Size 15 Dia.And 30Ht. Ndc Or Equivalent,Brown Wood Slated Finish With Pastel Blue Green Lids (Refer Image) Made Up Of Frp Consisting Of Binani Matt Fibres With Gp Resin And Hardener Having A Minimum Of 600 Gsm For Small Size Products Upto 2400 Gsm For Large Size Products For Stability And Durability.Dustbin Must Be Paint By Duco Nc Base Paint Of Choice As Per Ral Code/Duco Catalogue For Good Quality Surface Finish.The Surface Of Dustbin Must Be Smooth Matt Finish. All Tools, Plants, Labour And Materials, Leads, Lifts, Etc Complete. As Directed By Engineer-In-Charge. , Providing And Fixing Of Cast Iron & Frp Benches Made Up Of Cast Iron Powder Coated Frames And Frp Strips Connected To The Frames With Gi Nut Bolt And Gi Clamps Etc. Complete Fitting Length 5 Feet Standard In Size. All Tools Plants, Machinery, Lifts, Transportation Complete. , Supply, Installation,Testing And Commissioning Of 50 Mm X 40 Mm Horizontal Openwell Submersible Pump Having Cast Iron Casing With Cast Iron Impeller, Aisi 410 Shaft. Pump With 5 Hp 2880 Rpm 415 Volts, 50 Hz Ac 3 Phase Electric Motor. Capacity: 270 / 220 Lpm @ 32 / 36 Mtr. Total Head And Digital Control Panel With Float Switch For 2 X 5 Hp Submersible Pumpsets Comprising Of Under Volts / Over Volts Protection, Reversal Phase Protection,Dry Running Protection. , Providing, Installing And Commmissioning Of Aquaguard Eureka Forbes Or Equivalent, Commericial & Industrial Water Treatment Plants Skid Mounted Type Ro Plant Of 500 Litres/Hr Capacity. The Plant Shall House Pressure Sand Filter (Psf) And Activated Carbon Filter (Acf) With The Capacity Providing Fixing 1300 Lph, Reverse Osmosis System With Capacity Of 250Lph, Antiscalant Dosing Sysytem, Micron Cartridge Filter, High Pressure Pump With The Capacity Of 1300 Lph, Uv System And Other Required Accessories Excluding The Cost Of Raw And Clear Storage Tank. All Plants, Equipments, Tools, Machinery, Leads, Lifts Complete. , Providing, Installing And Commissioning Of Water Cooler Of Bluestar Make Or Equivalent With Partial Stainless Steel Material Of 80 Litre Capacity. All Plants, Equipments, Tools, Machinery, Leads, Lifts Complete. , Preparation And Surface Treatment Of Formation. (Preparation And Surface Treatment Of Formation By Removing Mud And Slurry, Watering To The Extent Needed To Maintain The Desired Moisture Content, Trimming To The Required Line, Grade, Profile And Rolling With 8-10 Tonne Smooth Wheeled Roller, Complete As Per Clause 310.) , Scarifying Existing Bituminous Surface To A Depth Of 50 Mm By Mechanical Means (Scarifying The Existing Bituminous Road Surface To A Depth Of 50 Mm And Disposal Of Scarified Material With In All Lifts And Lead Upto 1000 Metres.) , Bituminous Macadam (Providing And Laying Bituminous Macadam With 100-120 Tph Hot Mix Plant Producing Anaverage Output Of 75 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading Premixed With Bituminous Binder, Transported To Site, Laid Over A Previously Prepared Surface With Paver Finisher To The Required Grade, Level And Alignment And Rolled As Per Mort& H Specifications, Fifth Edition For Grading I ( 40 Mm Nominal Size ) , Excavation For Roadway In Soil By Mechanical Means Including Cutting And Pushing The Earth To Site Of Embankement Lead 50 Metres), Including Trimming Bottom And Side Slopes In Accordance With Requirements Of Lines, Grades And Cross Sections.As Per Morth Specification 301 , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.(A) Size 30 Cm L X 50 Cm H X 15 Cm T , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. A)Size 900 X 400 X 150 Mm With Steel Reinforcement Not Less Than 7 Kg Per Unit -30 T Capacity , Supplying And Fixing Of Precast Reinforced Cement Concrete Slabs(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) At Site In Concrete Grade Of M-25 With 20 Mm Nominal Size Granitic Or Basaltic Aggregate, Consolidated By Means Of Mechanical Platform, Vibration Etc. With Lifting Hooks Of M.S. 10Mm Bars And Pvc Cups Including Cost Of Reincforcement, Certificate From Manufacturer Shall Be Produced Indicating Grade Of Concret And Minimum Content Of Steel In The Product Along With 5 Year Free Replacement Warranty In Case Of Breakage Complete And As Directed By Engineer -In -Charge. B)Size 700 X 500 X 75 Mm With Steel Reinforcemnt Not Less Than 3.0 Kgs Per Unit , Supplying And Stacking Laterite Stones Of Size 150-200 Mm(Contractors Stone) For Soling At Site , Laying Stone Soiling Including Packing With Smaller Stones And Consolidation With Road Roller Including Spreading, Watering And Consolidating Of Binding Material Murrum Or Earth Etc.(Payment To Be Made For Quantity Of Only Soling Stone Used Excluding Binding Material) , Providing And Applying Tack Coat With Bitumen Grade Of 80/100 Or Bitumen Emulsion Using Pressure Distributor On The Prepared Bituminous/Granular Surface Cleaned With Mechanical Broom As Per Mort&H Specifications Clause 503. , Providing And Laying Bituminious Concrete With 40-60 Tph Drum Mix Type Hhot Mix Plant Producing An Average Output Of 50 Tonnes Per Hour Using Crushed Aggregates Of Specified Grading, Premixed With Bituminious Binder To Mix With Filler, Transporting The Hotmix To Work Site, With All Leads Laying With A Mechanical Paver Finisher To The Required Grade, Level And Alignment, Using Antistripping Agent Rolling With Smooth Wheeled, Vibratory Or Tandem Rollers To Achieve The Desired Compaction Complete As Per Mort& Specifications Clause 509 Grade-Ii (13Mm Nominal Size) @ 6.5% Bitumen Of Grade 60/70 Antistripping Agent @ 0.5% Of Bitumen Content , Providing And Laying 30 Mm Thick Bituminious/Asphaltic Concrete With 40-60 Batch Type Hmp Producing An Average Output Of 50 Tonnes Per Hour Using Crushed Aggregates Of Specified Gradings Premixed With Bituminious Binder At 6.5 % By Weight Of Total Mix And Fillerusing Antistripping Agent Transpoting The Hotmix To Work Site With All Leads And Applying A Tack Coat @F 2.00 Kg/10Sq.M. With Hot Bitumen Of 80/100 And Laying With Mechanical Paver Finisher To The Required Grade, Level And Alignment, Rolling With Smooth Wheeled, Vibratory Or Tandem Rollers To Achieve The Desired Compaction As Per Mort&H Specifications Clause 509 And 503 A) Antistripping Agent @ 0.5% Of Bitumen Content , Providing And Laying Of Hot Applied Thermoplastic Compound 2.5 Mm Thick Including Reflectorising Glass Beads @ 250 Gms Per Sqm Area, Thickness Of 2.5 Mm Isexclusive Of Surface Applied Glass Beads As Per Irc : 35. The Finished Surface To Be Level Uniform And Free From Streaks And Holes As Per Morth Specification 803 , Electrical Works , Street Light Panel: Supply, Installation, Testing And Commissioning Of Lt Panel Ip- 67 Outdoor Type,Floor Mounted Panels Shall Be Suitable For 415 V, 3 Phase, 4 Wire, 50Hz Supply System. With 3 Phase Energy Meter And 63A Tpn Mcb As Incommer And 8 Nos 16 A Tpn Mcb As Outgoing With Microcontoller Based Programmable Digital Almac Timer With Voltage Stabilizer, Outdoor Body Should Be Powder Coated. As Shown In Sld. , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. A) 4 Core 10 Sq.Mm , Supply Of 3 1/2 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.A) 3 1/2 Core 35 Sq.Mm , Supply Of 3 Core Unarmoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. A)3 Core 2.5 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(A) 4 X 10 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 3 1/2 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(A) 3 1/2 X 35 Sq. Mm. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 3 Core Pvc Insulated Pvc Sheathed /Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.(A) 3 X 1.5/2.5 Sq. Mm. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge, Sand Cushioning With Screened Sand Bed Of 20Mm Thick, Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(B) In Rocky Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run (The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required.(B) In Rocky Strata , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 400 Sq.Mm In The Existing Reinforced Cement Concrete /Hume / Stoneware Metal Pipe, Etc. Complete As Required , Earthing With Gi Earth Pipe 2 Mts Long 40 Mm Dia Medium Class With Isi Mark,Of Approved Brands, Including Accessories And Providing Masonry Enclosure With Ci/Rcc Cover Having Locking /Lifting Arrangement And Watering Pipe Etc. With Charcoal Or Coke And Salt) As Required As Per The Earthing Drawing Provided By The Engineer-Incharge.The Scope Of Work Includes The Following: A) Excavation Of Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) And Disposal Of Excavated Soil. B) Class B Gi Pipe, 40Mm Diameter As Per Specifications. C) Charcoal/Salt As Per Specs. D) Refilling The Pit Of Size 1.0X1.0X 2.0 Mtrs(Min) With Soft Black Soil Of Minimum Resistivity I/C Transportation. E)Masonary Chamber With Proper Foundation, Cover Plate And Locking Arrangement. F) Testing Of Earth Value With Earth Megger And Certifications Of Its Value. Aluminium Tag With Embossed Earthing Value To Be Attached To The Pipe. G) Watering Arrangement(B) In Rocky Strata , Providing And Fixing 6 Swg Dia Gi Wire On Surface Or In Recess For Loop Arthing Along With Existing Surface/ Recessed Conduit/ Submain Wiring/ Cable As Required , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supply And Erection Of 8 Mtrs Octoganal Pappeared H.D.G.I Pole Made Out Of 4 M.M. Thick Plate And Heavy Provision For Cable Entry, Having Weight Not Less Than 97Kg. 4 Nos Of J Type M24x 750Mm Long Foundation Bolts Of Grade En 8 As Specified By Ged. Along With Suitable Arm And Led Fixture Of Inled Make Specified By Ged Of 80 W , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (A) Sp, Cat A , Laying And Fixing With Collars Light Duty Non-Pressure Np 2 Class Reinforced Cement Concrete Pipes With Cement Mortar In Proportion 1:2 (1 Cement : 2 Fine Sand) In Joints Including Cost Of Jointing Material Etc. Complete.A) 300 Mm Dia Pipe , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Independent Surface/ Recessed Frls Pvc Conduit Of Appropriate Size As Required.(B) 2 X 2.5 Sq.Mm + 1 X 2.5 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Circuit/ Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor Single Core Cable In The Independent Surface/ Recessed Frls Pvc Conduit Of Appropriate Size As Required.(C) 2 X 4 Sq.Mm + 1 X 4 Sq.Mm Earthwire (20Mm Conduit) , Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit With Modular Switch, Modular Plates, Suitable Size Modular Gi Box Of Specified Category And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required.(C) Group C -- With Cat A Modular Accessories , Wiring For Group Controlled Light Point/ Fan Point/ Exhaust Fan Point/ Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface/ Recessed Pvc Conduit And Earthing The Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable Etc. As Required. , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 3 Pin 5/6 A Modular Socket Outlet And 5/16 A Modular Switch Connection Painting Etc. As Required.(A) Cat A , Supplying And Fixing Suitable Size Modular Gi Box With Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 6 Pin 15/16 A And 5/6 A Modular Socket Outlet Modular Socket Outlet And 15/16 A Modular Switch Connection Painting Etc. As Required.A) Cat A , Supplying And Fixing Modular Blanking Plate On The Existing Modular Plate Switch Box Excluding Modular Plate Etc. As Required (A) Cat A , Supply And Erecting Of 12 Inch (300 Mm Sweep) Exhaust Fan, 1400 Rpm, Complete With All Accessories. (A) Cat A , Supplying And Fixing Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required (A) Cat A , Supply And Erecting Fan Hook Box (100 Mm Diameter Or Equivalent Square Size, 75Mm Deep) Fabricated Out Of 16 Swg Sheet Steel With 10 M Round Bar Hook Bounded To Reinforced Cement Concrete Steel Upto 50 Mm Length Protruding On Each Side Of The Box, Including Painting With 2 Coats Of Red Oxide, Complete As Required. , Supply And Erecting Of 56 Inch (1400 Mm Sweep) Ceiling Fan, Double Ball Bearing Type, Complete With All Accessories. (A) Cat A , Supplying And Erecting Led Surface Lights Of 5 To 8 W, 230V Intergral Type With Required Driver And All The Required Accessories Of Legro, Wipro, Crompton, Bajaj, Havels Make Or Equivalet Approved By Engineer - In - Charge Complete As Required. , Supply, Erection,Testing & Commissioning Of 20 - 24 W Led Tubelight Luminaire.With Required Driver And Other Accessories Of Legro, Wipro, Crompton, Bajaj, Havels Or Equivalent Make Approved By Engineer - In - Charge Complete As Required. , Supplying And Fixing Following Way Spn Sheet Steel Mcb Distribution Board 240 V On Surface/ Recess Complete With Tinned Copper Busbar Neutral Busbar Earth Bar Dinnbar Detachable Gland Plate Interconnections Phosphotized And Powder Painted Including Earthing Etc. As Required ( But Without Mcb/Rccb/Isolator) (C) 12 Way Single Door Cat A , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required. (E) Tpn, Cat A , Supply And Erecting Meter Box Suitable For Three Phase Energy Meter And Incoming Sp/Dp Mcb, Fabricated Out Of 16 Swg Sheet Steel, Powder Coated, Complete As Required And Conforming To The Requirements Of Goa Electricity Deaprtment. , Supply, Installation, Testing And Commissioning Of Electronic Type Three Phase Energy Meter (Kwh), 4 Wire, Isi Marked, In Polycarbonate Or Sgheet Steel Body ( Base Mounting Type) With Counter Display/Lcd Display, With Elt, In Class 1.0, 50 Hz, 240 V. Ac Duly Tested By Mrt Along With Test Certificates, Complete As Required Of Following Capacity Of Make L & T Only.(B) 10 To 40 A , Supplying And Fixing Sp Blanking Plate In The Existing Mcb Db Complete As Required
Contract Date: Jun 12, 2026 Contract Value : 3.82 Crore
Government Departments No of Bidders 2
25.
Educational and Research Institute #10293210 Price Bid
Supply Of Ebooks And Hosting Platform Supply Of Ebooks (One-Year Term), Along With Digital Platform To Ebooks (Three-Year Term) , E-Books (1 Year) And Digital Platform (3 Years) , Dynamics -Md Raisinghania-S Chand , Numerical Methods-S R K Iyengar, R.K. Jain-New Age International Publishers , Advanced Engineering Mathematics-Erwin Kreyszig-Wiley , Engineering Mathematics - I-N.P. Bali-Lakshmi , Engineering Mathematics - Iii-N.P. Bali-Lakshmi , Engineering Mathematics - Ii-N.P. Bali-Lakshmi , Probability And Statistics For Engineer And Scientist -Walpole,-Pearson , Higher Engineering Mathematics-B.V.Raman-Mc Graw Hill , Python Programming-A Modular Approach -Taneja Sheetal, Kumar Naveen-Pearson , C:How To Program-H.M. Deitel,P.J. Deitel-Pearson , Data Structures Using C-A M Tenenbaum, Y Langsam And Mj Augenstein-Pearson , Optics Eb-Ghatak-Mc Graw Hill , Thomas Calculus-Maurice D. Weir,Joel Hass-Pearson , Cloud Computing-Insights Into New Era Infrastructure, Kumar Saurabh-Wiley , Machine Learning Using Python-Pradhan-Wiley , Devops Tools From Practitioner’S Viewpoint-Deepak Gaikwad, Viral Thakkar-Wiley , The Internet Of Things: Key Applications And Protocol-Olivier Hersent, David Boswarthick & Omar Elloumi-Wiley , Algorithms Design-M T Goodrich Etal-Wiley , Fundamentals Of Software Engineering-Rajib Mall-Phi , Pattern Classification-R. O. Duda, P. E. Hart, D. G. Stork (2000)-Wiley , Design Thinking For Strategic Innovation-Idrismootee-Wiley , Computer Organization-Ghosh-Mc Graw Hill , Neural Networks And Learning Machines- Simon Haykin-Pearson , Fundamentals Of Database System-Elmasri & Navathe-Pearson , Computer Vision: A Modern Approach-Forsyth, D. A. And Ponce, J.-Pearson , . Modern Operating System-Andrew Tanenbaum-Pearson , Operating System-William Staling-Pearson , Computer System Architecture-M. Morris Mano-Pearson , Python Programming-A Modular Approach -Taneja Sheetal, Kumar Naveen-Pearson , Data Structure Using C-A Y. Langsam, M. Augenstein And A. M. Tanenbaum-Pearson , Fundamentals Of Database Systems-R. Elmasri And S.B. Navathe-Pearson , Programming In Ansi C-E. Balaguruswamy-Mc Graw Hill , Computer Organization And Architecture - Designing For Performance-W. Stallings-Pearson , Computer Networking A Top-Down Approach -Kurose & Ross-Pearson , Uses Of Energy, Minerals And Changing Techniques-Chatterjee, K.K.-New Age International Publishers , Mechanics Of Solids (As Per Gujarat Technical University Syllabus)-Bhavikatti, S.S.-New Age International Publishers , Geoinformatics-Chandra, A.M.-New Age International Publishers , Engineering Graphics-Chandra, A.M.-New Age International Publishers , Computer Aided Engineeringdrawing(As Per Latest Vtu Syllabus)-Annaiah, M.H.-New Age International Publishers , Applied Numerical Methods Using Matlab-Dukkipati, Rao V.-New Age International Publishers , Solid And Fluid Mechanics-Bhavikatti, S.S.-New Age International Publishers , Analysis Of Thin Concrete Shells-Chandrashekhara, K.-New Age International Publishers , Engineering Mechanics And Elements Of Civil Engineering-Bhavikatti, S.S.-New Age International Publishers , Finite Element Analysis-Bhavikatti, S.S.-New Age International Publishers , Highway Engineering-Chandra, A.M.-New Age International Publishers , Remote Sensing: Theory & Applications-Garg, P.K.-New Age International Publishers , Structural Engineering Handbook-Bhavikatti, S.S.-New Age International Publishers , Higher Surveying-Chandra, A.M.-New Age International Publishers , Basics Of Remote Sensing And Gis -Dr. S. Kumar-Lakshmi , Design For Rcc Slabs - A Ready Reckoner-K.C. Jain-Lakshmi , Management Concepts For Civil Engineers-K. Anbuvelan-Lakshmi , Reinforced Concrete Structures Vol. I-Dr. B.C. Punmia, Ashok Kr. Jain, Arun Kr. Jain-Lakshmi , Project Planning And Control With Pert And Cpm-Dr. B.C. Punmia & K.K. Khandelwal (I.A.S.)-Lakshmi , Water Supply Engineering-Dr. B.C. Punmia, Ashok Kr. Jain, Arun Kr. Jain-Lakshmi , Geoinformation For Development-Peter Zeil, Stefan Kienberger-Lakshmi , Ground Improvement Techniques-Nihar Ranjan Patra-Vikas Publishing House , Textbook Of Project Management-P Gopalakrishnan & V E Ramamoorthy-Lakshmi , A Simplified Approach To Concrete Technology-P.K.Nag-Lakshmi , Surveying - Vol. 1 Eb-Duggal-Mc Graw Hill , Surveying - Vol. 2 Eb-Duggal-Mc Graw Hill , Material Management Indian Railways-Dr. C.L. Bansotra-Lakshmi , A Textbook Of Hydrology-Dr. P. Jaya Rami Reddy-Lakshmi , Concrete Technology-Dr Aminul Islam Laskar-Lakshmi , Basic Civil And Mechanical Engineering-Dr. S.Suyambazahahan, M.K.Thangamani Bindu-Lakshmi , Textbook Of Engineering Geology-Dr. N. Chenna Kesavulu-Lakshmi , Design Of Green Building And Environment-Er. V.K.Jain-Lakshmi , Python Programming – A Modular Approach-Taneja Sheetal, Kumar Naveen-Pearson , High Voltage Engineering By C.L. Wadhwa-C.L. Wadhwa-New Age International Publishers , Control System Engineering-I.J. Nagrath & M. Gopal-New Age International Publishers , Modern Control System Theory, 2/E, New Age Publishers, 1984.-M. Gopal-New Age International Publishers , Power System Operation And Control (2Nd Edition) By C.L. Wadhwa-C.L. Wadhwa-New Age International Publishers , Power Electronics Essentials And Applications-L. Umanand-Wiley , Special Electrical Machines- 2014-E.G. Janardhanan-Phi , Introduction To The Constitution Of India By Sharma, Brij Kishore, Phi-Brij Kishore Sharma-Phi , Engineering Electromagnetics By John Buck And William H. Hayt-John A. Buck & William H. Hayt-Mc Graw Hill , Numerical Methods For Engineers By Steven C. Chapra, Raymond P. Canale · 2016-Steven C. Chapra & Raymond P. Canale-Mc Graw Hill , Electrical Power Transmission And Distribution” Sivanagaraju S. Satyanarayana S. Pearson Learning, New Delhi-S. Sivanagaraju & S. Satyanarayana-Pearson , Signals And Systems, By Alan S. Willsky, Alan V. Oppenheim, And Ian T. Young-Alan V. Oppenheim, Alan S. Willsky & Ian T. Young-Pearson , Electric Machines-D.P. Kothari & I.J. Nagrath-Mc Graw Hill , Network Analysis -M.E. Van Valkenburg-Pearson , Power System Protection And Switchgear- 2011-Badri Ram & D.N. Vishwakarma-Mc Graw Hill , Introduction To Robotics: Mechanics And Control -John J. Craig-Pearson , Electric Traction: Motive Power And Energy Supply -F.B. Shaw-Cbs , Control System-Sinha,N.K.-New Age International Publishers , Control System Engineering-Nagrath,I.J.;Gopal,M.-New Age International Publishers , Networks And Systems-D.Roy Choudhary-New Age International Publishers , Fundamentals Of Microelectronics-Behzad Razavi-Wiley , Electronic Devices And Circuit Theory-Boylestad-Pearson , Basic Electrical Engineering -D.C. Kulshreshtha-Mc Graw Hill , Signals And Systems-Simon Haykin And Barry Van Veen-Wiley , Artificial Intelligence -Khemani-Mc Graw Hill , Signals And Systems -Rao, P. R.-Mc Graw Hill , Basic Electrical And Electronics Engineering-Kothari Dp And I.J Nagrath-Mc Graw Hill , Transducers And Instrumentation-Dvs Murty-Phi , Signals And Systems -3Rd. Ed.-A. Anand Kumar-Phi , Control Systems Principles And Design-Gopal M.-Mc Graw Hill , Digit Cont & State Var Met Eb-Gopal M.-Mc Graw Hill , Ebook Grobs Basic Electronics-Schultz-Mc Graw Hill , Fundamentals Of Electromagnetics For Electrical And Computer Engineering-Narayana Rao, N.-Pearson , Modern Control Engineering-K. Ogata-Pearson , Nonlinear Control, Global Edition-Khalil H. K-Pearson , Electrical And Electronics Technology- E. Hughes-Pearson , Electronic Devices-Thomas L. Floyd-Pearson , Elements Of Electronic Instrumentation And Measurement Technique-J J Carr-Pearson , Digital Design-M.Morris Mano-Pearson , Advanced Theory Of Vibration-Rao, J.S.-New Age International Publishers , Finite Element Methods Vs. Classical Methods-Rao, H.S.G.-New Age International Publishers , Manufacturing Technology - I-C. Elanchezhian, B. Vijaya Ramnath-Lakshmi , Manufacturing Technology - Ii-Dr. R.Kesavan, B. Vijaya Ramanath-Lakshmi , Machine Design -Rajendra Karwa-Lakshmi , Mechanical Vibrations, 2Nd Edition-Mehta J.S. And Kailey A.S.-S Chand , Engineering Graphics - Kaushik Kumar, Apurba Kumar Roy & Chikesh Ranjan-S Chand , Atb Of Finite Element Methods-R.N.Reddy-Lakshmi , Kinematics, Dynamics, And Design Of Machinery, 3Ed-Waldron-Wiley , Computer Aided Manufacturing-C. Elanchizhian, T. Sunder Selwyn, G. Shamunga Sunder-Lakshmi , Engineering Mechanics-Dr. I.S. Gujral-Lakshmi , Engineering Fluid Mechanics-K. L. Kumar-S Chand , Mechatronics-Cetinkunt-Wiley , Thermal Engineering-Mahesh Rathore-Mc Graw Hill , Shigleys Mechanical Engineering Design-Keith Nisbett And Richard Budynas-Mc Graw Hill , Fundamentals Of Heat And Mass Transfer-Thirumaleshwar-Pearson , Internal Combustion Engines Eb-V. Ganesan-Mc Graw Hill , Fluid Mechanics: Fundamentals And Applications-Cengel And Cimbala-Mc Graw Hill , Theory Of Machines Eb-Rattan-Mc Graw Hill , Machine Design Data Book Eb-Bhandari-Mc Graw Hill , Strength Of Materials -S S Rattan-Mc Graw Hill , Design Of Machine Elements -V B Bhandari-Mc Graw Hill , Essentials Of Supply Chain Management-Hugos, M. (2011). -Wiley , Future Of Human Resource Management: Case Studies With Strategic Approach-Preet, R. (2019).-Wiley , Beginning R: The Statistical Programming Language-Gardener, M. (2013).-Wiley , Managerial Economics-Dwivedi, D. N. (2021). -Vikas Publishing House , Statistics For Management-Levin, R.I., Rubin, D. S., Rastogi S. & Siddiqui, M.H. (2017).-Pearson , Operations Research: Principles And Practice-Ravindran, A., Phillips, D. T & Solberg, J. J. (2009).-Wiley , Project Management: A Managerial Approach-Meredith, J.R. & Mantel, Jr., S.J.. (2003). -Wiley , Operations And Supply Chain Management-Russel & Taylor Indian Edition.-Wiley , Urban Transit Systems And Technology- Vukan R. Vuchic-Wiley , Supply Chain Management: Strategy, Planning And Operations-Chopra, S. & Meindl, P. (2013). -Pearson , Linear Programming And Network Flows-Bazaraa, M. S., Jarvis, J. J. And Sherali, H. D.(2010).-Wiley , Financial Accounting For Management -Ramchandran, N. & Kakani, R. K. (2020)-Mc Graw Hill , The R Book-Crawley, M. J. (2013). -Wiley , Marketing Management-Shainesh, G., Kotler, P., Keller, K.L., Chernev, A. & Sheth, J. N. -Pearson , Supply Chain Management For Competitive Advantage: Concepts & Cases-Rangaraj, N. & And Raghuram, G. (2015). -Mc Graw Hill , Statistics For Business-Robert Stine, Dean Foster-Pearson , Managerial Economics-Gupta, G. S. (2017). -Mc Graw Hill , Business Research Methods-Pamela Schindler-Mc Graw Hill , Organizational Behavior Emerging Knowledge Global Reality-Mcshane, S. & Glinow, M. A. V. (2020). -Mc Graw Hill , Investments (11Th Edition)-Zvi Bodie, Alex Kane, Alan J. Marcus, Pitabas Mohanty-Mc Graw Hill , Applied Statistics In Business And Economics -Doane, D. P., & Seward, L. W. (2022).-Mc Graw Hill , Business Statistics-Sanjiv Jaggia; Alison Kelly-Mc Graw Hill , Principles Of Corporate Finance.-Brealey, R. & Myers, S. (2013).-Mc Graw Hill , Matching Supply With Demand-Gerard Cachon, Christian Terwiesch-Mc Graw Hill , Services Marketing: Integrating Customer Focus Across The Firm-Zeithaml, V. A., Bitner, M. J., & Gremler, D. D. (2017). -Mc Graw Hill , Ebook Ola For Essentials Of Business Statistics-Jaggia-Mc Graw Hill , Organizational Behavior. -Robbins, S.P., Timothy A. Judge, T. A. & Vohra, N. (2022). -Pearson , Ethics And The Conduct Of Business By Boatright- J. R., Smith, J. D., & Patra, B. P.-Pearson , Microeconomics -Pindyck, R. & Rubinfeld, D. (2017). -Pearson , Derivatives And Risk Management-Madhumathi R, Ranganatham M-Pearson , International Trade And Export Management -Cherunilam, F. (2021).-Himalaya , Operations Management: Theory And Practice.-Mahadevan, B. (2018). -Pearson , Transportation Engineering-Khisty, C. J., & Lall, B. K. (2017).-Pearson , Human Resource Management-Dessler, G. & Varkkey, B. (2017)-Pearson , Horngrens Cost Accounting: A Managerial Emphasis (16Th Ed.)-Srikant Datar, Madhav Rajan-Pearson , Operations Management-Heizer, J.& Render, B. (2018). -Pearson , Macroeconomics: Theory And Policy Eb-Dwivedi-Mc Graw Hill , Business Ethics- An Indian Perspective -Fernando-Pearson , Introduction To Material Management-Chapman, N. S., & Et Al. (2017).-Pearson , Management Information Systems: Managing The Digital Firm - Kc Laudon And Jp Laudon-Pearson , Introduction To Operations Research (Sie)-Hillier, F. & Lieberman, G. (2021).-Mc Graw Hill , Designing And Managing The Supply Chain: Concepts, Strategies & Case Studies-D. Simchi-Levi, E. Simchi-Levi & Shankar, R. (2008). -Mc Graw Hill , Financial Management: Theory And Practice. -Chandra, P. (2019).-Mc Graw Hill , International Business: Text And Cases-. Cherunilam, F. (N.D.).-Himalaya , Financial Management-Berg / Stork-Pearson , Principles Of Marketing-Kotler, P., Armstrong, G., Balasubramanian, S. & Agnihotri, P.-Pearson , Research Methodology: Methods And Techniques-C.R. Kothari, C. R. & Garg, G. (2019).-New Age International Publishers , Digital E-Books Hosting Platform (3 Years Subscription)
Contract Date: Ref. Documents Contract Value : Ref. Document
Private Organizations No of Bidders 2
26.
Drinking Water Supply and Sanitation #10284414 Price Bid
Fixing Of Rate Contract For Repairs/Replacement To Mechanical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Bijbehara (District Anantnag And Kulgam) For The Financial Year 2023-24- 1 Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: 2 Private car, auto-rickshaw or similar with 1.0 km lead 3 Extra per kilometer for lead >1.0 kms upto 5.0 kms 4 Extra per kilometer for lead >5.0 kms upto 10.0 kms 5 Extra per kilometer for lead >10.0 kms upto 20.0 kms 6 Extra per kilometer for lead >20.0 kms upto 30.0 kms 7 Load carrier auto, mini van or similar with 1.0 km lead 8 Extra per kilometer for lead >1.0 kms upto 5.0 kms 9 Extra per kilometer for lead >5.0 kms upto 10.0 kms 10 Extra per kilometer for lead >10.0 kms upto 20.0 kms 11 Extra per kilometer for lead >20.0 kms upto 30.0 kms 12 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 13 Extra per kilometer for lead >1.0 kms upto 5.0 kms 14 Extra per kilometer for lead >5.0 kms upto 10.0 kms 15 Extra per kilometer for lead >10.0 kms upto 20.0 kms 16 Extra per kilometer for lead >20.0 kms upto 30.0 kms 17 Truck, tipper or similar with 1.0 km lead 18 Extra per kilometer for lead >1.0 kms upto 5.0 kms 19 Extra per kilometer for lead >5.0 kms upto 10.0 kms 20 Extra per kilometer for lead >10.0 kms upto 20.0 kms 21 Extra per kilometer for lead >20.0 kms upto 30.0 kms 22 Head load carriage of machinery/ equipment at locations inaccessible by vehicles on plain/ rough terrain 23 Upto 50 kgs load 24 Extra for every additional 50kgs load (Note: Fraction >=25kgs shall be taken as equivalent to next load of 50kgs) 25 Extra for uphill terrain (Ground Slope >= 07 deg) 26 PUMPSComplete dismantling of VT pump by way of:Disconnecting all leads from the motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor with stool. Disassembling, dismantling and segregation of various pump parts such as discharge and column pipes, shafts and couplings, bowl, suction bell, impeller, stuffing box, fasteners, etc. 27 Single stage pumps with single column pipe upto 300mm ND 28 Single stage pumps with single column pipe > 300mm upto 600mm ND 29 Single stage pumps with single column pipe > 600mm ND 30 Extra per additional stage over corresponding column pipe size rates above 31 Extra per additional column pipe over corresponding column pipe size rates above 32 Complete assembling of all VT pump parts after cleaning, coupling and alignment with motor, connecting of motor leads and testing on full load. 33 Single stage pumps with single column pipe upto 300mm ND 34 Single stage pumps with single column pipe > 300mm upto 600mm ND 35 Single stage pumps with single column pipe > 600mm ND 36 Extra per additional stage over corresponding column pipe size rates above 37 Extra per additional column pipe over corresponding column pipe size rates above 38 Complete dismantling of single stage horizontal pump (all types) by way of:Disconnecting all leads from the motor and marking the terminals, uncoupling of motor from the pump. Disassembling, dismantling and segregation of various pump parts such as shaft and sleeves, impeller, gland, fasteners, etc. 39 Suction size upto 200mm 40 Suction size > 200mm upto 400mm 41 Suction size >400mm 42 Extra per additional stage over corresponding suction sizes above 43 Complete assembling of single stage horizontal pump (all types) after cleaning of all parts throughly with petrol, coupling and alignment with motor, connecting of motor leads and testing on full load. 44 Suction size upto 200mm 45 Suction size > 200mm upto 400mm 46 Suction size >400mm 47 Extra per additional stage over corresponding suction sizes above 48 Partial dismantling of VT pump by way of:Disconnecting all leads from the motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor with stool. Disassembling, dismantling and segregation of various pump parts including discharge and column pipe, head and line shafts and couplings but excluding bowl assembly. 49 Pumps with single column pipe upto 300mm ND 50 Pumps with single column pipe > 300mm upto 600mm ND 51 Pumps with single column pipe > 600mm ND 52 Extra per additional column pipe over corresponding column pipe size rates above 53 Assembling of dismantled VT pump parts (excluding bowl assembly) after cleaning, coupling and alignment with motor, connecting of motor leads and testing on full load. 54 Pumps with single column pipe upto 300mm ND 55 Pumps with single column pipe > 300mm upto 600mm ND 56 Pumps with single column pipe > 600mm ND 57 Extra per additional column pipe over corresponding column pipe size rates above 58 Removal of only stuffing box from the pump. 59 Fitting of only stuffing box to the pump. 60 Replacement of Driving End (DE) bearing of horizontal/ vertical pump by way of:Uncoupling of motor from the pump, isolating of DE bearing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of pump parts, coupling and alignment with the pump. The job includes load testing of pump. 61 Suction size upto 200mm 62 Suction size > 200mm upto 400mm 63 Suction size >400mm 64 Replacement of Non-Driving End (NDE) bearing of horizontal pump by way of:Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of pump parts, coupling and alignment with the pump. The job includes load testing of pump. 65 Suction size upto 200mm 66 Suction size > 200mm upto 400mm 67 Suction size >400mm 68 Extraction of submersible pump/motor set along with column pipes from the well by hoisting with tripod and chain pulley block and by using tools and tackles required for extraction of pump set and uncoupling the pump and motor 69 Column pipes upto 100mm NB and 50mtr depth 70 For depths exceeding 50m 71 Extra over corresponding depth level for pipes >100mm NB 72 Assembling of submersible pump/ motor set and lowering along with column pipes in the well by chain pulley block, tripod, tools and tackles and testing on full load at site. 73 Column pipes upto 100mm NB and 50mtr depth 74 For depths exceeding 50m 75 Extra over corresponding depth level for pipes >100mm ND 76 VALVESRemoval from piping system and complete dismantling of various type of valves such as foot valves/ butterfly valves/ NRVs/ check valves/ sluice valves (without spur gear mechanism) by way of disassembling of parts, etc. 77 < 100mm nominal size 78 >=100mm upto 200mm nominal size 79 > 200mm upto 350mm nominal size 80 >350mm upto 600mm nominal size 81 > 600mm nominal size 82 Assembling of all parts of dismantled valve, fitting in the piping system and testing. 83 < 100mm nominal size 84 >=100mm upto 200mm nominal size 85 > 200mm upto 350mm nominal size 86 >350mm upto 600mm nominal size 87 > 600mm nominal size 88 Disassembling of operating mechanism of large sized valves to isolate the thrust bearing and removing it, cleaning of housing, fitting of bearing, reassembling of all parts and testing. The job is inclusive of hoisting arrangements required for execution of work. 89 Partial dismantling of various types of valves such as NRVs, sluice valves, butterfly valves, flap valves, etc. for repairs or replacement of parts such as hinge pin/ seat ring/ disc face/ hinge repairs, etc. and reassembling of all parts of dismantled valve and testing. 90 <100mm nominal size 91 >=100mm upto 200mm nominal size 92 >200mm upto 350mm nominal size 93 >350mm upto 600mm nominal size 94 > 600mm nominal size 95 Complete removal of foot valve (all sizes) from the pump suction system and refitting and testing after carrying out the requisite works but excluding the cost of repairs/ replacements carried out on the foot valve 96 POLESDismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. 97 Erection of metallic pole of following lengths in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) standard/ suitable foundation including excavation and refilling etc. as required. 98 Above 4.5 meter and upto 6.5 meter 99 Above 6.5 meter and upto 8.0 meter 100 Above 8.0 meter and upto 10.0 meter 101 Above 10.00 meter and upto 12.00 meter 102 PUMP PARTSFabrication, providing and fitting of GM bush to bell mouth/ bowl unit/ stuffing box/ sleeve, or similar as per sample having finished weight as under: 103 upto 1.0 kg 104 Extra per kg >1.0 kg upto 2.5 kgs 105 Extra per kg >2.5kgs upto 5.0 kgs 106 Extra per kg > 5.0 kgs 107 Fabrication, providing and fitting of GM bush with rubber insert (Cutlass bearing) to bowl housing/ bearing retainer, etc as per sample having finished weight as under: 108 upto 1.0 kg 109 Extra per kg >1.0 kg upto 2.5 kgs 110 Extra per kg >2.5kgs upto 5.0 kgs 111 Extra per kg > 5.0 kgs 112 Fabrication, providing and fitting of GM lantern (cooling) ring for stuffing box as per sample having finished weight as under: 113 upto 1.0 kg 114 Extra per kg >1.0kgs upto 2.0 kgs 115 Extra per kg > 2.0 kgs 116 Providing and fitting of GM split gland as per sample having finished weight as under: 117 upto 1.0 kg 118 Extra per kg >1.0 kg upto 2.5 kgs 119 Extra per kg >2.5kgs upto 4.0 kgs 120 Extra per kg > 4.0 kgs 121 Fabrication, turning and finishing (on inside and outside) of Stainless steel(AISI-410 or IS 1030) muff coupling, etc. as per old sample having finished weight as under: 122 Fabrication, turning and finishing of specified Stainless Steel (AISI-410 or IS 1570) shaft of specified dimensions with end preparation (threaded, etc.), keyway as per old sample having finished weight as under: 123 upto 20.0 kg 124 Extra per kg >20.0 kg upto 40 kgs 125 Extra per kg >40kgs upto 60 kgs 126 Extra per kg > 60 kgs 127 Fabrication, turning and finishing (on inside and outside) of Stainless steel(IS 1030) shaft coupling, etc. as per old sample having finished weight as under: 128 Fabrication, turning, finishing and fitting of Stainless steel (AISI-410 or IS 1570)shaft sleeve as per old sample, etc. having finished weight as under: 129 Manufacturing, finishing, providing of SS (AISI 410 or IS 1570) key/ impeller lock collet as per available sample and slot size. 130 Fabrication, turning and threading of Stainless steel shaft stud as per old sample etc. 131 Manufacturing, providing and fitting of SS (IS 1030) check nut/ impeller adjusting nut with proper locking arrangement as per sample available. 132 Providing and fitting of Cast Iron split gland as per sample: 133 upto 1.0 kg 134 Extra per kg >1.0 kg upto 2.5 kgs 135 Extra per kg >2.5kgs upto 5.0 kgs 136 Extra per kg > 5.0 kgs 137 Fabrication, providing and fitting of GM/bronze impeller wear ring/ seal ring/ sand collar 138 upto 1.0 kg 139 Extra per kg >1.0 kg upto 2.5 kgs 140 Extra per kg >2.5kgs upto 5.0 kgs 141 Extra per kg > 5.0 kgs 142 Fabrication, providing and fitting of CI Casing ring 143 upto 1.0 kg 144 Extra per kg >1.0 kg upto 2.5 kgs 145 Extra per kg >2.5kgs upto 5.0 kgs 146 Extra per kg > 5.0 kgs 147 Fabrication, providing and fitting of MS strainer for suction bell, etc. The strainer shall be applied with one coat of approved metal primer and two coats of anticorrosive bituminous paint to give an even shade. 148 Rethreading of bolt hole using appropriate tap drill 149 upto M12 size hole/ bore 150 > M12 size hole/ bore 151 Repairs to damaged SS shaft by way of rebuilding of shaft using high quality SS electrodes (Ador/ Advani/ ESAB makes) and then turning the shaft on lathe machine to remove the excess material deposited and restore the original dimensions and profile of the shaft. 152 Shaft upto 50mm diameter at one damaged spot on shaft length 153 Extra for each subsequent damaged spot over the corresponding diameter upto 50mm 154 Shaft of more than 50mm diameter at one damaged spot on shaft length 155 Extra for each subsequent damaged spot over the corresponding diameter above 50mm 156 Repairs to the existing damaged SS shaft end by way of rebuilding using high quality SS electrodes (Ador/ Advani/ ESAB makes) and then turning the shaft on lathe machine to remove the excess material deposited. The job includes threading or collar rebuilding and facing, etc. as per requirement and restore the original dimensions and profile of the shaft. 157 Shaft upto 50mm diameter at one damaged spot on shaft end 158 Extra for each subsequent damaged spot over the corresponding diameter upto 50mm 159 Shaft of more than 50mm diameter at one damaged spot on shaft end 160 Extra for each subsequent damaged spot over the corresponding diameter above 50mm 161 COUPLINGSProviding and fitting bush type flexible coupling with finished bore and keyway of following designations (Preferred make: Fenner/ Lovejoy/ or equivalent makes and designations) 162 FBC-1 (max. bore upto 28mm) 163 FBC-2 (max. bore upto 30mm) 164 FBC-2A (max. bore upto 42mm) 165 FBC-3 (max. bore upto 48mm) 166 FBC-4 (max. bore upto 65mm) 167 FBC-4A (max. bore upto 65mm) 168 FBC-5 (max. bore upto 75mm) 169 FBC-6 (max. bore upto 95mm) 170 FBC-6A (max. bore upto 95mm) 171 FBC-6B (max. bore upto 95mm) 172 FBC-7 (max. bore upto 15mm) 173 FBC-7A (max. bore upto 120mm) 174 FBC-8 (max. bore upto 130mm) 175 FBC-8A (max. bore upto 135mm) 176 FBC-8B (max. bore upto 140mm) 177 FBC-9 (max. bore upto 150mm) 178 FBC-9A (max. bore upto 160mm) 179 FBC-10 (max. bore upto 170mm) 180 FBC-10A (max. bore upto 180mm) 181 FBC-11 (max. bore upto 190mm) 182 Providing and fitting of rubber bush for bush type flexible couplings as under: 183 FBC-1 upto FBC-2A 184 FBC-3 upto FBC-8A 185 FBC-8B upto FBC-11 186 Providing and fitting of pin for bush type flexible couplings as under: 187 FBC-1 upto FBC-2A 188 FBC-3 upto FBC-7 189 FBC-7A upto FBC-8A 190 FBC-8B upto FBC-10 191 FBC-10A upto FBC-11 192 Providing and fitting flexible tyre coupling with finished bore and keyway of following designations as per IS 14285:(Note: Number in designation indicates dim. A approx tyre outer dia) 193 TC-104 (TC-007) 194 TC-133 (TC-009) 195 TC 165 (TC-0012) 196 TC-197 (TC-0013) 197 TC-211 (TC-0014) 198 TC-235 (TC-0015) 199 TC-254 (TC-0016) 200 TC-279 (TC-0017) 201 TC-314 (TC-0019) 202 TC-359 (TC-0020/21) 203 TC-402 (TC-0022) 204 TC-470 (TC-0023) 205 TC-508 (TC-0024) 206 TC-562 (TC-0025) 207 TC-628 208 Providing and fitting spare tyre for tyre coupling of following designations as per IS 14285: 209 TC-104 (TC-007) 210 TC-133 (TC-009) 211 TC 165 (TC-0012) 212 TC-197 (TC-0013) 213 TC-211 (TC-0014) 214 TC-235 (TC-0015) 215 TC-254 (TC-0016) 216 TC-279 (TC-0017) 217 TC-314 (TC-0019) 218 TC-359 (TC-0020/21) 219 TC-402 (TC-0022) 220 TC-470 (TC-0023) 221 TC-508 (TC-0024) 222 TC-562 (TC-0025) 223 TC-628 224 FASTENERSProviding of high tensile steel hexagonal bolts 225 M6 x 50 226 M8 x 80 227 M10 x 80 228 M12 x 80 229 M14 x 90 230 M16 x 100 231 M18 x 50 232 M18 x 125 233 M18 x 150 234 M20 x 100 235 M22 x 90 236 M22 x 125 237 M22 x 150 238 M24 x 90 239 M24 x 100 240 M24 x 150 241 M27 x 120 242 M30 x 110 243 Providing of hexagonal nuts of suitable pitch with sizes as under: 244 M6 245 M8 246 M10 247 M12 248 M14 249 M16 250 M18 251 M20 252 M22 253 M24 254 M27 255 M30 256 Providing and fitting of carbon steel Fasteners of assorted sizes 257 Fabrication, providing and fitting of SS/ alloy steel hinge pin for all types of valves, etc. as per old sample but excluding the cost of extracting the old pin and dismantling/reassembling the valve, etc. 258 Fabrication & providing of new bronze body seat ring/ bronze wedge facing ring/ bronze stem nut/ float guide as per sample for various valves but excluding cost of dismantling the valve parts 259 upto 1.0 kg 260 Extra per kg >1.0 kg upto 2.5 kgs 261 Extra per kg >2.5kgs upto 4.0 kgs 262 Providing and fitting of rubber gasket for various types of valves 263 Providing of jute/ hemp gland packing 264 Fabrication & providing of new SS stem nut/ stem-spindle/ pinion/ pinion shaft/ stub shaft (AISI-410 or IS 6603) for sluice/ butterfly or other type of valve as per old sample 265 upto 20.0 kg 266 Extra per kg >20.0 kg upto 40 kgs 267 Extra per kg >40kgs upto 60 kgs 268 Extra per kg > 60 kgs 269 FOOT VALVEFabrication, providing and fitting of CI disc plate as per old sample 270 Providing of leather disc face washer for foot valve 271 Labour for fitting of washer to foot valve including removal of foot valve from suction line, extraction of old damaged washer, fitting of new (available) washer and refitting of foot valve to suction line. 272 Providing and fitting of screwed type GM foot valve conforming to IS-4038 of nominal size: 273 15mm 274 20mm 275 25mm 276 32mm 277 40mm 278 FLANGESProviding and welding of steel plate flanges of nominal pressure rating 1.0MPa as per IS 6392 with nominal sizes as under: 279 32mm 280 40mm 281 50mm 282 65mm 283 80mm 284 100mm 285 125mm 286 150mm 287 200mm 288 250mm 289 300mm 290 350mm 291 Providing and welding of steel plate flanges of nominal pressure rating 1.6MPa as per IS 6392 with nominal sizes as under: 292 32mm 293 40mm 294 50mm 295 65mm 296 80mm 297 100mm 298 125mm 299 150mm 300 200mm 301 250mm 302 300mm 303 350mm 304 Providing and welding of steel plate blind flanges as per IS 6392 of nominal pressure rating 1.6MPa with nominal sizes as under: 305 50mm 306 65mm 307 80mm 308 100mm 309 125mm 310 150mm 311 200mm 312 250mm 313 300mm 314 350mm 315 GASKETProviding of natural rubber gasket for flanged joints with nominal sizes as under: 316 32mm 317 40mm 318 50mm 319 65mm 320 80mm 321 100mm 322 125mm 323 150mm 324 200mm 325 250mm 326 300mm 327 350mm 328 400mm 329 Providing and fiiting of C classonforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well 330 DN 50C(Heavy) pipe 331 DN65C(Heavy) pipe 332 DN80C(Heavy) pipe 333 Providing/supplying and fitting of G.I flanged Rising Main as per requirment 334 DN 50C (Heavy) pipe 335 DN65C (Heavy) pipe 336 DN80C (Heavy) pipe 337 DN100C (Heavy) pipe 338 DN125C (Heavy) pipe 339 DN150C (Heavy) pipe 340 DN 200C (Heavy) pipe, 6mm Thick 341 DN 50B (Medium) pipe 342 DN65B (Medium) pipe 343 DN80B (Medium) pipe 344 DN100B (Medium) pipe 345 DN125B (Medium) pipe 346 DN150B (Medium) pipe 347 Providing/Fitting of new bearing as under: (Make: SKF imported/ equivalent imported) 348 No. 3210 A/C3 349 No. 3212 A/C3 350 No. 3213 A/C3 351 No. 3309 A/C3 352 No. 3313 A/C3 353 No. 51310 354 No. 51312 355 No. 51314 356 No. 51320 357 No. 6014 358 No. 6220 359 No. 6314 360 No. 6315 361 No. 6320 362 No. 6324 363 No. 6406 364 No. 6408 365 No. 6410 366 No. 6411 367 No. 6412 368 No. 6415 369 No. 6418 370 No. NU322 ECJ 371 No. NU324 ECJ 372 No. 29322 E 373 No. 29324 E 374 No. 29328 E 375 No. 29330 E 376 No. 29424 E 377 No. 29426 E 378 Providing/Fitting of new bearing as under: (Make: Schaeffler (FAG)imported/ equivalent imported) 379 No. 6220 380 No. 6317 381 No. 6318 382 No. 6319 383 No. 6320 384 No. 29322-E1-XL 385 29324-E1-XL 386 No. 29326-E1-XL 387 No. 29328-E1-XL 388 No. 29330-E1-XL 389 No. 29424-E1-XL 390 No. 29426-E1-XL 391 Providing/Fitting of new bearing as under: (NBC/ ARB/ ZKL/ equivalent domestic) 392 No. 3210 393 No. 3212 394 No. 3213 395 No. 3306 396 No. 3307 397 No. 3309 398 No. 3310 399 No. 3311 400 No. 3312 401 No. 3313 402 No. 51310 403 No. 51312 404 No. 51314 405 No. 51320 406 No. 51322 407 No. 6014 408 No. 6028 409 No. 6217 410 No. 6220 411 No. 6305 412 No. 6306 413 No. 6307 414 No. 6308 415 No. 6309 416 No. 6310 417 No. 6311 418 No. 6312 419 No. 6313 420 No. 6314 421 No. 6315 422 No. 6320 423 No. 6322 424 No. 6406 425 No. 6408 426 No. 6410 427 No. 6411 428 No. 6412 429 No. 6415 430 No. 7312 431 Providing and fitting of new plummer block/ bearing housing with designation as under: (Prefered makes: Masta/ SIBCO) 432 S 507 433 S 508 434 S 509 435 S 510 436 S 511 437 S 512 438 S 513 439 S 515 440 S 516 441 S 517 442 S 518 443 S 519 444 S 520 445 S 522 446 S 524 447 Hiring of portable diesel engine operated pumpset for dewatering around workspace of pipes, etc. excluding fuel charges 448 Structural steel work in single section fixed without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 449 Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 450 Cutting charges of Mild steel pipes/ plates including cost of consumables, etc.but excluding the cost of transportation charges of equipment to site 451 Using grinder 452 By gas cutting 453 Welding charges of prepared Mild steel sections, etc including cost of consumables, etc. but excluding carriage of equipment to site, etc. 454 By electric welding 455 By gas welding 456 Hiring of mobile crane upto 5 Ton capacity 457 Hiring of excavator for earthwork excavation. 458 WTPProviding and fitting of 5kg/cm2, 12mm connection PP/ PE filter nozzle on bed of pressure filter vessel 459 Providing and laying of filter media (filter gravel and course sand) of specific size and grade in 5000/ 6000 GPH pressure vessel, duly washed and free from dust, dirt, loom and any other material or suspension. The job includes carriage of filter media including all loads and lifts. The media shall be laid in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilting or damaging the pressure nozzles. 460 Providing of Grease (industrial type) conforming to IS 7623(Preferred makes: HPCL Lithon-3/ Indian oil Servogem-3/ or equivalents of BPCL; Castrol; Caltex) 461 Providing of AP3 Grease (all purpose type)(Preferred makes: HPCL/ Indian oil/ BPCL/ Castrol/ Caltex) 462 Providing of mineral oil for bearing lubrication(Preferred make: Indian Oil Servo/ HPCL/ BPCL Mak/ Shell Mobil) 463 Providing of graphited natural fibre packing for pumps, etc.(Preferred make: Champion Style-3116 or equivalent) 464 Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m 465 Pipes, cables etc, not exceeding 80 mm dia. 466 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 467 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia 468 Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia 469 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). 470 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) 471 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 472 Gravel packing in tube well in accordance with IS: 4097, including providing gravel fine/ medium/ coarse in required grading and sizes as per actual requirement all complete as per direction of Engineer-in-charge. 473 PAINTING FOR REPAIRED PUMPS/ STEEL WORK 474 Removing of old paint, rust, foreign contaminants etc. from pump body (internal & external), structural work (gratings, any type of frame work, etc.) motor body or other equipment by scrapping, cleaning, rubbing, chipping by any means & preparing the surface to receive new coat of paint. The cost including cost of materials, labours, scaffolding etc. to complete the job at site as per direction of Engineer In Charge. 475 Providing & application of Primer (Epilux-610 Grey or any other approved brand) on cleaned surface of pump body (internal or external)/ motor body/ structral framework/ gratings, etc. including thinner (Epilux - 844 or any other approved brand) brush & other materials as required, labours, scaffolding etc. to complete the work at site as per direction of Engineer In Charge.For 1st coat of Primer (Manual painting) 476 Cost for supplying & application of coal tar epoxy Paint (Epilux-5 or any other approved brand) on cleaned surface of pump body/ motor body/ any stuctural framework, gratings including thinner (Epilux-844 or any other approved brand) & other materials as required, labours, brush, painting equipments etc. to complete the work at site as per direction of Engineer In Charge. 477 For 1st coat of Paint(Manual painting) 478 For 2nd coat of Paint(Manual painting) 479 Painting (two or more coats) on pipes and fittings with black anticorrosive bitumastic paint of approved brand over and including a priming coat of ready mixed zinc chromate yellow primer 480 Painting (two or more coats) with synthetic enamel paint of approved brand over cleaned/ prepared surfaces. 481 Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): 482 Hiring charges of Labourer for support of electrician
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
27.
Drinking Water Supply and Sanitation #10284412 Price Bid
Fixing Of Rate Contract For Repairs/Replacement To Mechanical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Pampore (District Pulwama) For The Financial Year 2023-24- 1 Mechanical transportation, loading, unloading and handling of various items such as pump parts, motors, starters, voltage stabilizers, coil assemblies, welding tools & plant, etc. using appropriate means of transport as under: 2 Private car, auto-rickshaw or similar with 1.0 km lead 3 Extra per kilometer for lead >1.0 kms upto 5.0 kms 4 Extra per kilometer for lead >5.0 kms upto 10.0 kms 5 Extra per kilometer for lead >10.0 kms upto 20.0 kms 6 Extra per kilometer for lead >20.0 kms upto 30.0 kms 7 Load carrier auto, mini van or similar with 1.0 km lead 8 Extra per kilometer for lead >1.0 kms upto 5.0 kms 9 Extra per kilometer for lead >5.0 kms upto 10.0 kms 10 Extra per kilometer for lead >10.0 kms upto 20.0 kms 11 Extra per kilometer for lead >20.0 kms upto 30.0 kms 12 Mini truck like Tata mobile, Bolero Camper or similar with 1.0 km lead 13 Extra per kilometer for lead >1.0 kms upto 5.0 kms 14 Extra per kilometer for lead >5.0 kms upto 10.0 kms 15 Extra per kilometer for lead >10.0 kms upto 20.0 kms 16 Extra per kilometer for lead >20.0 kms upto 30.0 kms 17 Truck, tipper or similar with 1.0 km lead 18 Extra per kilometer for lead >1.0 kms upto 5.0 kms 19 Extra per kilometer for lead >5.0 kms upto 10.0 kms 20 Extra per kilometer for lead >10.0 kms upto 20.0 kms 21 Extra per kilometer for lead >20.0 kms upto 30.0 kms 22 Head load carriage of machinery/ equipment at locations inaccessible by vehicles on plain/ rough terrain 23 Upto 50 kgs load 24 Extra for every additional 50kgs load (Note: Fraction >=25kgs shall be taken as equivalent to next load of 50kgs) 25 Extra for uphill terrain (Ground Slope >= 07 deg) 26 PUMPSComplete dismantling of VT pump by way of:Disconnecting all leads from the motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor with stool. Disassembling, dismantling and segregation of various pump parts such as discharge and column pipes, shafts and couplings, bowl, suction bell, impeller, stuffing box, fasteners, etc. 27 Single stage pumps with single column pipe upto 300mm ND 28 Single stage pumps with single column pipe > 300mm upto 600mm ND 29 Single stage pumps with single column pipe > 600mm ND 30 Extra per additional stage over corresponding column pipe size rates above 31 Extra per additional column pipe over corresponding column pipe size rates above 32 Complete assembling of all VT pump parts after cleaning, coupling and alignment with motor, connecting of motor leads and testing on full load. 33 Single stage pumps with single column pipe upto 300mm ND 34 Single stage pumps with single column pipe > 300mm upto 600mm ND 35 Single stage pumps with single column pipe > 600mm ND 36 Extra per additional stage over corresponding column pipe size rates above 37 Extra per additional column pipe over corresponding column pipe size rates above 38 Complete dismantling of single stage horizontal pump (all types) by way of:Disconnecting all leads from the motor and marking the terminals, uncoupling of motor from the pump. Disassembling, dismantling and segregation of various pump parts such as shaft and sleeves, impeller, gland, fasteners, etc. 39 Suction size upto 200mm 40 Suction size > 200mm upto 400mm 41 Suction size >400mm 42 Extra per additional stage over corresponding suction sizes above 43 Complete assembling of single stage horizontal pump (all types) after cleaning of all parts throughly with petrol, coupling and alignment with motor, connecting of motor leads and testing on full load. 44 Suction size upto 200mm 45 Suction size > 200mm upto 400mm 46 Suction size >400mm 47 Extra per additional stage over corresponding suction sizes above 48 Partial dismantling of VT pump by way of:Disconnecting all leads from the motor and marking the terminals, uncoupling of motor from the pump, dismounting of motor with stool. Disassembling, dismantling and segregation of various pump parts including discharge and column pipe, head and line shafts and couplings but excluding bowl assembly. 49 Pumps with single column pipe upto 300mm ND 50 Pumps with single column pipe > 300mm upto 600mm ND 51 Pumps with single column pipe > 600mm ND 52 Extra per additional column pipe over corresponding column pipe size rates above 53 Assembling of dismantled VT pump parts (excluding bowl assembly) after cleaning, coupling and alignment with motor, connecting of motor leads and testing on full load. 54 Pumps with single column pipe upto 300mm ND 55 Pumps with single column pipe > 300mm upto 600mm ND 56 Pumps with single column pipe > 600mm ND 57 Extra per additional column pipe over corresponding column pipe size rates above 58 Removal of only stuffing box from the pump. 59 Fitting of only stuffing box to the pump. 60 Replacement of Driving End (DE) bearing of horizontal/ vertical pump by way of:Uncoupling of motor from the pump, isolating of DE bearing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of pump parts, coupling and alignment with the pump. The job includes load testing of pump. 61 Suction size upto 200mm 62 Suction size > 200mm upto 400mm 63 Suction size >400mm 64 Replacement of Non-Driving End (NDE) bearing of horizontal pump by way of:Opening the end cover of NDE bearing housing. Carefully extracting the old damaged bearing from the housing with the help of bearing puller, etc and fitting of new bearing in its place. Refitting back of pump parts, coupling and alignment with the pump. The job includes load testing of pump. 65 Suction size upto 200mm 66 Suction size > 200mm upto 400mm 67 Suction size >400mm 68 Extraction of submersible pump/motor set along with column pipes from the well by hoisting with tripod and chain pulley block and by using tools and tackles required for extraction of pump set and uncoupling the pump and motor 69 Column pipes upto 100mm NB and 50mtr depth 70 For depths exceeding 50m 71 Extra over corresponding depth level for pipes >100mm NB 72 Assembling of submersible pump/ motor set and lowering along with column pipes in the well by chain pulley block, tripod, tools and tackles and testing on full load at site. 73 Column pipes upto 100mm NB and 50mtr depth 74 For depths exceeding 50m 75 Extra over corresponding depth level for pipes >100mm ND 76 VALVESRemoval from piping system and complete dismantling of various type of valves such as foot valves/ butterfly valves/ NRVs/ check valves/ sluice valves (without spur gear mechanism) by way of disassembling of parts, etc. 77 < 100mm nominal size 78 >=100mm upto 200mm nominal size 79 > 200mm upto 350mm nominal size 80 >350mm upto 600mm nominal size 81 > 600mm nominal size 82 Assembling of all parts of dismantled valve, fitting in the piping system and testing. 83 < 100mm nominal size 84 >=100mm upto 200mm nominal size 85 > 200mm upto 350mm nominal size 86 >350mm upto 600mm nominal size 87 > 600mm nominal size 88 Disassembling of operating mechanism of large sized valves to isolate the thrust bearing and removing it, cleaning of housing, fitting of bearing, reassembling of all parts and testing. The job is inclusive of hoisting arrangements required for execution of work. 89 Partial dismantling of various types of valves such as NRVs, sluice valves, butterfly valves, flap valves, etc. for repairs or replacement of parts such as hinge pin/ seat ring/ disc face/ hinge repairs, etc. and reassembling of all parts of dismantled valve and testing. 90 <100mm nominal size 91 >=100mm upto 200mm nominal size 92 >200mm upto 350mm nominal size 93 >350mm upto 600mm nominal size 94 > 600mm nominal size 95 Complete removal of foot valve (all sizes) from the pump suction system and refitting and testing after carrying out the requisite works but excluding the cost of repairs/ replacements carried out on the foot valve 96 POLESDismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required. 97 Erection of metallic pole of following lengths in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) standard/ suitable foundation including excavation and refilling etc. as required. 98 Above 4.5 meter and upto 6.5 meter 99 Above 6.5 meter and upto 8.0 meter 100 Above 8.0 meter and upto 10.0 meter 101 Above 10.00 meter and upto 12.00 meter 102 PUMP PARTSFabrication, providing and fitting of GM bush to bell mouth/ bowl unit/ stuffing box/ sleeve, or similar as per sample having finished weight as under: 103 upto 1.0 kg 104 Extra per kg >1.0 kg upto 2.5 kgs 105 Extra per kg >2.5kgs upto 5.0 kgs 106 Extra per kg > 5.0 kgs 107 Fabrication, providing and fitting of GM bush with rubber insert (Cutlass bearing) to bowl housing/ bearing retainer, etc as per sample having finished weight as under: 108 upto 1.0 kg 109 Extra per kg >1.0 kg upto 2.5 kgs 110 Extra per kg >2.5kgs upto 5.0 kgs 111 Extra per kg > 5.0 kgs 112 Fabrication, providing and fitting of GM lantern (cooling) ring for stuffing box as per sample having finished weight as under: 113 upto 1.0 kg 114 Extra per kg >1.0kgs upto 2.0 kgs 115 Extra per kg > 2.0 kgs 116 Providing and fitting of GM split gland as per sample having finished weight as under: 117 upto 1.0 kg 118 Extra per kg >1.0 kg upto 2.5 kgs 119 Extra per kg >2.5kgs upto 4.0 kgs 120 Extra per kg > 4.0 kgs 121 Fabrication, turning and finishing (on inside and outside) of Stainless steel(AISI-410 or IS 1030) muff coupling, etc. as per old sample having finished weight as under: 122 Fabrication, turning and finishing of specified Stainless Steel (AISI-410 or IS 1570) shaft of specified dimensions with end preparation (threaded, etc.), keyway as per old sample having finished weight as under: 123 upto 20.0 kg 124 Extra per kg >20.0 kg upto 40 kgs 125 Extra per kg >40kgs upto 60 kgs 126 Extra per kg > 60 kgs 127 Fabrication, turning and finishing (on inside and outside) of Stainless steel(IS 1030) shaft coupling, etc. as per old sample having finished weight as under: 128 Fabrication, turning, finishing and fitting of Stainless steel (AISI-410 or IS 1570)shaft sleeve as per old sample, etc. having finished weight as under: 129 Manufacturing, finishing, providing of SS (AISI 410 or IS 1570) key/ impeller lock collet as per available sample and slot size. 130 Fabrication, turning and threading of Stainless steel shaft stud as per old sample etc. 131 Manufacturing, providing and fitting of SS (IS 1030) check nut/ impeller adjusting nut with proper locking arrangement as per sample available. 132 Providing and fitting of Cast Iron split gland as per sample: 133 upto 1.0 kg 134 Extra per kg >1.0 kg upto 2.5 kgs 135 Extra per kg >2.5kgs upto 5.0 kgs 136 Extra per kg > 5.0 kgs 137 Fabrication, providing and fitting of GM/bronze impeller wear ring/ seal ring/ sand collar 138 upto 1.0 kg 139 Extra per kg >1.0 kg upto 2.5 kgs 140 Extra per kg >2.5kgs upto 5.0 kgs 141 Extra per kg > 5.0 kgs 142 Fabrication, providing and fitting of CI Casing ring 143 upto 1.0 kg 144 Extra per kg >1.0 kg upto 2.5 kgs 145 Extra per kg >2.5kgs upto 5.0 kgs 146 Extra per kg > 5.0 kgs 147 Fabrication, providing and fitting of MS strainer for suction bell, etc. The strainer shall be applied with one coat of approved metal primer and two coats of anticorrosive bituminous paint to give an even shade. 148 Rethreading of bolt hole using appropriate tap drill 149 upto M12 size hole/ bore 150 > M12 size hole/ bore 151 Repairs to damaged SS shaft by way of rebuilding of shaft using high quality SS electrodes (Ador/ Advani/ ESAB makes) and then turning the shaft on lathe machine to remove the excess material deposited and restore the original dimensions and profile of the shaft. 152 Shaft upto 50mm diameter at one damaged spot on shaft length 153 Extra for each subsequent damaged spot over the corresponding diameter upto 50mm 154 Shaft of more than 50mm diameter at one damaged spot on shaft length 155 Extra for each subsequent damaged spot over the corresponding diameter above 50mm 156 Repairs to the existing damaged SS shaft end by way of rebuilding using high quality SS electrodes (Ador/ Advani/ ESAB makes) and then turning the shaft on lathe machine to remove the excess material deposited. The job includes threading or collar rebuilding and facing, etc. as per requirement and restore the original dimensions and profile of the shaft. 157 Shaft upto 50mm diameter at one damaged spot on shaft end 158 Extra for each subsequent damaged spot over the corresponding diameter upto 50mm 159 Shaft of more than 50mm diameter at one damaged spot on shaft end 160 Extra for each subsequent damaged spot over the corresponding diameter above 50mm 161 COUPLINGSProviding and fitting bush type flexible coupling with finished bore and keyway of following designations (Preferred make: Fenner/ Lovejoy/ or equivalent makes and designations) 162 FBC-1 (max. bore upto 28mm) 163 FBC-2 (max. bore upto 30mm) 164 FBC-2A (max. bore upto 42mm) 165 FBC-3 (max. bore upto 48mm) 166 FBC-4 (max. bore upto 65mm) 167 FBC-4A (max. bore upto 65mm) 168 FBC-5 (max. bore upto 75mm) 169 FBC-6 (max. bore upto 95mm) 170 FBC-6A (max. bore upto 95mm) 171 FBC-6B (max. bore upto 95mm) 172 FBC-7 (max. bore upto 15mm) 173 FBC-7A (max. bore upto 120mm) 174 FBC-8 (max. bore upto 130mm) 175 FBC-8A (max. bore upto 135mm) 176 FBC-8B (max. bore upto 140mm) 177 FBC-9 (max. bore upto 150mm) 178 FBC-9A (max. bore upto 160mm) 179 FBC-10 (max. bore upto 170mm) 180 FBC-10A (max. bore upto 180mm) 181 FBC-11 (max. bore upto 190mm) 182 Providing and fitting of rubber bush for bush type flexible couplings as under: 183 FBC-1 upto FBC-2A 184 FBC-3 upto FBC-8A 185 FBC-8B upto FBC-11 186 Providing and fitting of pin for bush type flexible couplings as under: 187 FBC-1 upto FBC-2A 188 FBC-3 upto FBC-7 189 FBC-7A upto FBC-8A 190 FBC-8B upto FBC-10 191 FBC-10A upto FBC-11 192 Providing and fitting flexible tyre coupling with finished bore and keyway of following designations as per IS 14285:(Note: Number in designation indicates dim. A approx tyre outer dia) 193 TC-104 (TC-007) 194 TC-133 (TC-009) 195 TC 165 (TC-0012) 196 TC-197 (TC-0013) 197 TC-211 (TC-0014) 198 TC-235 (TC-0015) 199 TC-254 (TC-0016) 200 TC-279 (TC-0017) 201 TC-314 (TC-0019) 202 TC-359 (TC-0020/21) 203 TC-402 (TC-0022) 204 TC-470 (TC-0023) 205 TC-508 (TC-0024) 206 TC-562 (TC-0025) 207 TC-628 208 Providing and fitting spare tyre for tyre coupling of following designations as per IS 14285: 209 TC-104 (TC-007) 210 TC-133 (TC-009) 211 TC 165 (TC-0012) 212 TC-197 (TC-0013) 213 TC-211 (TC-0014) 214 TC-235 (TC-0015) 215 TC-254 (TC-0016) 216 TC-279 (TC-0017) 217 TC-314 (TC-0019) 218 TC-359 (TC-0020/21) 219 TC-402 (TC-0022) 220 TC-470 (TC-0023) 221 TC-508 (TC-0024) 222 TC-562 (TC-0025) 223 TC-628 224 FASTENERSProviding of high tensile steel hexagonal bolts 225 M6 x 50 226 M8 x 80 227 M10 x 80 228 M12 x 80 229 M14 x 90 230 M16 x 100 231 M18 x 50 232 M18 x 125 233 M18 x 150 234 M20 x 100 235 M22 x 90 236 M22 x 125 237 M22 x 150 238 M24 x 90 239 M24 x 100 240 M24 x 150 241 M27 x 120 242 M30 x 110 243 Providing of hexagonal nuts of suitable pitch with sizes as under: 244 M6 245 M8 246 M10 247 M12 248 M14 249 M16 250 M18 251 M20 252 M22 253 M24 254 M27 255 M30 256 Providing and fitting of carbon steel Fasteners of assorted sizes 257 Fabrication, providing and fitting of SS/ alloy steel hinge pin for all types of valves, etc. as per old sample but excluding the cost of extracting the old pin and dismantling/reassembling the valve, etc. 258 Fabrication & providing of new bronze body seat ring/ bronze wedge facing ring/ bronze stem nut/ float guide as per sample for various valves but excluding cost of dismantling the valve parts 259 upto 1.0 kg 260 Extra per kg >1.0 kg upto 2.5 kgs 261 Extra per kg >2.5kgs upto 4.0 kgs 262 Providing and fitting of rubber gasket for various types of valves 263 Providing of jute/ hemp gland packing 264 Fabrication & providing of new SS stem nut/ stem-spindle/ pinion/ pinion shaft/ stub shaft (AISI-410 or IS 6603) for sluice/ butterfly or other type of valve as per old sample 265 upto 20.0 kg 266 Extra per kg >20.0 kg upto 40 kgs 267 Extra per kg >40kgs upto 60 kgs 268 Extra per kg > 60 kgs 269 FOOT VALVEFabrication, providing and fitting of CI disc plate as per old sample 270 Providing of leather disc face washer for foot valve 271 Labour for fitting of washer to foot valve including removal of foot valve from suction line, extraction of old damaged washer, fitting of new (available) washer and refitting of foot valve to suction line. 272 Providing and fitting of screwed type GM foot valve conforming to IS-4038 of nominal size: 273 15mm 274 20mm 275 25mm 276 32mm 277 40mm 278 FLANGESProviding and welding of steel plate flanges of nominal pressure rating 1.0MPa as per IS 6392 with nominal sizes as under: 279 32mm 280 40mm 281 50mm 282 65mm 283 80mm 284 100mm 285 125mm 286 150mm 287 200mm 288 250mm 289 300mm 290 350mm 291 Providing and welding of steel plate flanges of nominal pressure rating 1.6MPa as per IS 6392 with nominal sizes as under: 292 32mm 293 40mm 294 50mm 295 65mm 296 80mm 297 100mm 298 125mm 299 150mm 300 200mm 301 250mm 302 300mm 303 350mm 304 Providing and welding of steel plate blind flanges as per IS 6392 of nominal pressure rating 1.6MPa with nominal sizes as under: 305 50mm 306 65mm 307 80mm 308 100mm 309 125mm 310 150mm 311 200mm 312 250mm 313 300mm 314 350mm 315 GASKETProviding of natural rubber gasket for flanged joints with nominal sizes as under: 316 32mm 317 40mm 318 50mm 319 65mm 320 80mm 321 100mm 322 125mm 323 150mm 324 200mm 325 250mm 326 300mm 327 350mm 328 400mm 329 Providing and fiiting of C classonforming to IS: 1239 of length 10 Rft into the 200/ 250/300 mm casing dia. production well 330 DN 50C(Heavy) pipe 331 DN65C(Heavy) pipe 332 DN80C(Heavy) pipe 333 Providing/supplying and fitting of G.I flanged Rising Main as per requirment 334 DN 50C (Heavy) pipe 335 DN65C (Heavy) pipe 336 DN80C (Heavy) pipe 337 DN100C (Heavy) pipe 338 DN125C (Heavy) pipe 339 DN150C (Heavy) pipe 340 DN 200C (Heavy) pipe, 6mm Thick 341 DN 50B (Medium) pipe 342 DN65B (Medium) pipe 343 DN80B (Medium) pipe 344 DN100B (Medium) pipe 345 DN125B (Medium) pipe 346 DN150B (Medium) pipe 347 Providing/Fitting of new bearing as under: (Make: SKF imported/ equivalent imported) 348 No. 3210 A/C3 349 No. 3212 A/C3 350 No. 3213 A/C3 351 No. 3309 A/C3 352 No. 3313 A/C3 353 No. 51310 354 No. 51312 355 No. 51314 356 No. 51320 357 No. 6014 358 No. 6220 359 No. 6314 360 No. 6315 361 No. 6320 362 No. 6324 363 No. 6406 364 No. 6408 365 No. 6410 366 No. 6411 367 No. 6412 368 No. 6415 369 No. 6418 370 No. NU322 ECJ 371 No. NU324 ECJ 372 No. 29322 E 373 No. 29324 E 374 No. 29328 E 375 No. 29330 E 376 No. 29424 E 377 No. 29426 E 378 Providing/Fitting of new bearing as under: (Make: Schaeffler (FAG)imported/ equivalent imported) 379 No. 6220 380 No. 6317 381 No. 6318 382 No. 6319 383 No. 6320 384 No. 29322-E1-XL 385 29324-E1-XL 386 No. 29326-E1-XL 387 No. 29328-E1-XL 388 No. 29330-E1-XL 389 No. 29424-E1-XL 390 No. 29426-E1-XL 391 Providing/Fitting of new bearing as under: (NBC/ ARB/ ZKL/ equivalent domestic) 392 No. 3210 393 No. 3212 394 No. 3213 395 No. 3306 396 No. 3307 397 No. 3309 398 No. 3310 399 No. 3311 400 No. 3312 401 No. 3313 402 No. 51310 403 No. 51312 404 No. 51314 405 No. 51320 406 No. 51322 407 No. 6014 408 No. 6028 409 No. 6217 410 No. 6220 411 No. 6305 412 No. 6306 413 No. 6307 414 No. 6308 415 No. 6309 416 No. 6310 417 No. 6311 418 No. 6312 419 No. 6313 420 No. 6314 421 No. 6315 422 No. 6320 423 No. 6322 424 No. 6406 425 No. 6408 426 No. 6410 427 No. 6411 428 No. 6412 429 No. 6415 430 No. 7312 431 Providing and fitting of new plummer block/ bearing housing with designation as under: (Prefered makes: Masta/ SIBCO) 432 S 507 433 S 508 434 S 509 435 S 510 436 S 511 437 S 512 438 S 513 439 S 515 440 S 516 441 S 517 442 S 518 443 S 519 444 S 520 445 S 522 446 S 524 447 Hiring of portable diesel engine operated pumpset for dewatering around workspace of pipes, etc. excluding fuel charges 448 Structural steel work in single section fixed without connecting plate including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 449 Structural steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 450 Cutting charges of Mild steel pipes/ plates including cost of consumables, etc.but excluding the cost of transportation charges of equipment to site 451 Using grinder 452 By gas cutting 453 Welding charges of prepared Mild steel sections, etc including cost of consumables, etc. but excluding carriage of equipment to site, etc. 454 By electric welding 455 By gas welding 456 Hiring of mobile crane upto 5 Ton capacity 457 Hiring of excavator for earthwork excavation. 458 WTPProviding and fitting of 5kg/cm2, 12mm connection PP/ PE filter nozzle on bed of pressure filter vessel 459 Providing and laying of filter media (filter gravel and course sand) of specific size and grade in 5000/ 6000 GPH pressure vessel, duly washed and free from dust, dirt, loom and any other material or suspension. The job includes carriage of filter media including all loads and lifts. The media shall be laid in different layers of specific size and grade from bottom to top over the filter bed plate. The bottom layer is to be laid without tilting or damaging the pressure nozzles. 460 Providing of Grease (industrial type) conforming to IS 7623(Preferred makes: HPCL Lithon-3/ Indian oil Servogem-3/ or equivalents of BPCL; Castrol; Caltex) 461 Providing of AP3 Grease (all purpose type)(Preferred makes: HPCL/ Indian oil/ BPCL/ Castrol/ Caltex) 462 Providing of mineral oil for bearing lubrication(Preferred make: Indian Oil Servo/ HPCL/ BPCL Mak/ Shell Mobil) 463 Providing of graphited natural fibre packing for pumps, etc.(Preferred make: Champion Style-3116 or equivalent) 464 Excavating trenches of required width for pipes, cables, etc in all kinds of soil including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m 465 Pipes, cables etc, not exceeding 80 mm dia. 466 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 467 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm dia 468 Pipes, cables etc. exceeding 600 mm dia but not exceeding 1200 mm dia 469 Extra for excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3m. (Rate is over corresponding basic item for depth upto 1.5 metre). 470 Extra for excavating trenches for pipes, cables, etc, in all kinds of soil for depth exceeding 3 m in depth, but not exceeding 4.5 m. (Rate is over corresponding basic item for depth upto 1.5 metre.) 471 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. 472 Gravel packing in tube well in accordance with IS: 4097, including providing gravel fine/ medium/ coarse in required grading and sizes as per actual requirement all complete as per direction of Engineer-in-charge. 473 PAINTING FOR REPAIRED PUMPS/ STEEL WORK 474 Removing of old paint, rust, foreign contaminants etc. from pump body (internal & external), structural work (gratings, any type of frame work, etc.) motor body or other equipment by scrapping, cleaning, rubbing, chipping by any means & preparing the surface to receive new coat of paint. The cost including cost of materials, labours, scaffolding etc. to complete the job at site as per direction of Engineer In Charge. 475 Providing & application of Primer (Epilux-610 Grey or any other approved brand) on cleaned surface of pump body (internal or external)/ motor body/ structral framework/ gratings, etc. including thinner (Epilux - 844 or any other approved brand) brush & other materials as required, labours, scaffolding etc. to complete the work at site as per direction of Engineer In Charge.For 1st coat of Primer (Manual painting) 476 Cost for supplying & application of coal tar epoxy Paint (Epilux-5 or any other approved brand) on cleaned surface of pump body/ motor body/ any stuctural framework, gratings including thinner (Epilux-844 or any other approved brand) & other materials as required, labours, brush, painting equipments etc. to complete the work at site as per direction of Engineer In Charge. 477 For 1st coat of Paint(Manual painting) 478 For 2nd coat of Paint(Manual painting) 479 Painting (two or more coats) on pipes and fittings with black anticorrosive bitumastic paint of approved brand over and including a priming coat of ready mixed zinc chromate yellow primer 480 Painting (two or more coats) with synthetic enamel paint of approved brand over cleaned/ prepared surfaces. 481 Hiring charges of Electrician (for troubleshooting/ revamping of existing electrical fitting, etc. exclusive of specified works): 482 Hiring charges of Labourer for support of electrician
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
28.
Drinking Water Supply and Sanitation #10284404 Price Bid
Fixing Of Rate Contract For Repairs / Replacement To Mechanical Equipment Installed At Different Wsss Of Phe Mechanical Sub-Division Shopian ( District Pulwama And Shopian ) For The Financial Year 2023-24- 1 Mechanical Transportation, Loading, Unloading And Handling Of Various Items Such As Pump Parts, Motors, Starters, Voltage Stabilizers, Coil Assemblies, Welding Tools & Plant, Etc. Using Appropriate Means Of Transport As Under: 2 Private Car, Auto-Rickshaw Or Similar With 1.0 Km Lead 3 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 4 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 5 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 6 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 7 Load Carrier Auto, Mini Van Or Similar With 1.0 Km Lead 8 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 9 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 10 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 11 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 12 Mini Truck Like Tata Mobile, Bolero Camper Or Similar With 1.0 Km Lead 13 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 14 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 15 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 16 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 17 Truck, Tipper Or Similar With 1.0 Km Lead 18 Extra Per Kilometer For Lead >1.0 Kms Upto 5.0 Kms 19 Extra Per Kilometer For Lead >5.0 Kms Upto 10.0 Kms 20 Extra Per Kilometer For Lead >10.0 Kms Upto 20.0 Kms 21 Extra Per Kilometer For Lead >20.0 Kms Upto 30.0 Kms 22 Head Load Carriage Of Machinery / Equipment At Locations Inaccessible By Vehicles On Plain / Rough Terrain 23 Upto 50 Kgs Load 24 Extra For Every Additional 50Kgs Load ( Note: Fraction >=25Kgs Shall Be Taken As Equivalent To Next Load Of 50Kgs ) 25 Extra For Uphill Terrain ( Ground Slope >= 07 Deg ) 26 Pumpscomplete Dismantling Of Vt Pump By Way Of:Disconnecting All Leads From The Motor And Marking The Terminals, Uncoupling Of Motor From The Pump, Dismounting Of Motor With Stool. Disassembling, Dismantling And Segregation Of Various Pump Parts Such As Discharge And Column Pipes, Shafts And Couplings, Bowl, Suction Bell, Impeller, Stuffing Box, Fasteners, Etc. 27 Single Stage Pumps With Single Column Pipe Upto 300Mm Nd 28 Single Stage Pumps With Single Column Pipe > 300Mm Upto 600Mm Nd 29 Single Stage Pumps With Single Column Pipe > 600Mm Nd 30 Extra Per Additional Stage Over Corresponding Column Pipe Size Rates Above 31 Extra Per Additional Column Pipe Over Corresponding Column Pipe Size Rates Above 32 Complete Assembling Of All Vt Pump Parts After Cleaning, Coupling And Alignment With Motor, Connecting Of Motor Leads And Testing On Full Load. 33 Single Stage Pumps With Single Column Pipe Upto 300Mm Nd 34 Single Stage Pumps With Single Column Pipe > 300Mm Upto 600Mm Nd 35 Single Stage Pumps With Single Column Pipe > 600Mm Nd 36 Extra Per Additional Stage Over Corresponding Column Pipe Size Rates Above 37 Extra Per Additional Column Pipe Over Corresponding Column Pipe Size Rates Above 38 Complete Dismantling Of Single Stage Horizontal Pump ( All Types ) By Way Of:Disconnecting All Leads From The Motor And Marking The Terminals, Uncoupling Of Motor From The Pump. Disassembling, Dismantling And Segregation Of Various Pump Parts Such As Shaft And Sleeves, Impeller, Gland, Fasteners, Etc. 39 Suction Size Upto 200Mm 40 Suction Size > 200Mm Upto 400Mm 41 Suction Size >400Mm 42 Extra Per Additional Stage Over Corresponding Suction Sizes Above 43 Complete Assembling Of Single Stage Horizontal Pump ( All Types ) After Cleaning Of All Parts Throughly With Petrol, Coupling And Alignment With Motor, Connecting Of Motor Leads And Testing On Full Load. 44 Suction Size Upto 200Mm 45 Suction Size > 200Mm Upto 400Mm 46 Suction Size >400Mm 47 Extra Per Additional Stage Over Corresponding Suction Sizes Above 48 Partial Dismantling Of Vt Pump By Way Of:Disconnecting All Leads From The Motor And Marking The Terminals, Uncoupling Of Motor From The Pump, Dismounting Of Motor With Stool. Disassembling, Dismantling And Segregation Of Various Pump Parts Including Discharge And Column Pipe, Head And Line Shafts And Couplings But Excluding Bowl Assembly. 49 Pumps With Single Column Pipe Upto 300Mm Nd 50 Pumps With Single Column Pipe > 300Mm Upto 600Mm Nd 51 Pumps With Single Column Pipe > 600Mm Nd 52 Extra Per Additional Column Pipe Over Corresponding Column Pipe Size Rates Above 53 Assembling Of Dismantled Vt Pump Parts ( Excluding Bowl Assembly ) After Cleaning, Coupling And Alignment With Motor, Connecting Of Motor Leads And Testing On Full Load. 54 Pumps With Single Column Pipe Upto 300Mm Nd 55 Pumps With Single Column Pipe > 300Mm Upto 600Mm Nd 56 Pumps With Single Column Pipe > 600Mm Nd 57 Extra Per Additional Column Pipe Over Corresponding Column Pipe Size Rates Above 58 Removal Of Only Stuffing Box From The Pump. 59 Fitting Of Only Stuffing Box To The Pump. 60 Replacement Of Driving End ( De ) Bearing Of Horizontal / Vertical Pump By Way Of:Uncoupling Of Motor From The Pump, Isolating Of De Bearing. Carefully Extracting The Old Damaged Bearing From The Housing With The Help Of Bearing Puller, Etc And Fitting Of New Bearing In Its Place. Refitting Back Of Pump Parts, Coupling And Alignment With The Pump. The Job Includes Load Testing Of Pump. 61 Suction Size Upto 200Mm 62 Suction Size > 200Mm Upto 400Mm 63 Suction Size >400Mm 64 Replacement Of Non-Driving End ( Nde ) Bearing Of Horizontal Pump By Way Of:Opening The End Cover Of Nde Bearing Housing. Carefully Extracting The Old Damaged Bearing From The Housing With The Help Of Bearing Puller, Etc And Fitting Of New Bearing In Its Place. Refitting Back Of Pump Parts, Coupling And Alignment With The Pump. The Job Includes Load Testing Of Pump. 65 Suction Size Upto 200Mm 66 Suction Size > 200Mm Upto 400Mm 67 Suction Size >400Mm 68 Extraction Of Submersible Pump / Motor Set Along With Column Pipes From The Well By Hoisting With Tripod And Chain Pulley Block And By Using Tools And Tackles Required For Extraction Of Pump Set And Uncoupling The Pump And Motor 69 Column Pipes Upto 100Mm Nb And 50Mtr Depth 70 For Depths Exceeding 50M 71 Extra Over Corresponding Depth Level For Pipes >100Mm Nb 72 Assembling Of Submersible Pump / Motor Set And Lowering Along With Column Pipes In The Well By Chain Pulley Block, Tripod, Tools And Tackles And Testing On Full Load At Site. 73 Column Pipes Upto 100Mm Nb And 50Mtr Depth 74 For Depths Exceeding 50M 75 Extra Over Corresponding Depth Level For Pipes >100Mm Nd 76 Valvesremoval From Piping System And Complete Dismantling Of Various Type Of Valves Such As Foot Valves / Butterfly Valves / Nrvs / Check Valves / Sluice Valves ( Without Spur Gear Mechanism ) By Way Of Disassembling Of Parts, Etc. 77 < 100Mm Nominal Size 78 >=100Mm Upto 200Mm Nominal Size 79 > 200Mm Upto 350Mm Nominal Size 80 >350Mm Upto 600Mm Nominal Size 81 > 600Mm Nominal Size 82 Assembling Of All Parts Of Dismantled Valve, Fitting In The Piping System And Testing. 83 < 100Mm Nominal Size 84 >=100Mm Upto 200Mm Nominal Size 85 > 200Mm Upto 350Mm Nominal Size 86 >350Mm Upto 600Mm Nominal Size 87 > 600Mm Nominal Size 88 Disassembling Of Operating Mechanism Of Large Sized Valves To Isolate The Thrust Bearing And Removing It, Cleaning Of Housing, Fitting Of Bearing, Reassembling Of All Parts And Testing. The Job Is Inclusive Of Hoisting Arrangements Required For Execution Of Work. 89 Partial Dismantling Of Various Types Of Valves Such As Nrvs, Sluice Valves, Butterfly Valves, Flap Valves, Etc. For Repairs Or Replacement Of Parts Such As Hinge Pin / Seat Ring / Disc Face / Hinge Repairs, Etc. And Reassembling Of All Parts Of Dismantled Valve And Testing. 90 <100Mm Nominal Size 91 >=100Mm Upto 200Mm Nominal Size 92 >200Mm Upto 350Mm Nominal Size 93 >350Mm Upto 600Mm Nominal Size 94 > 600Mm Nominal Size 95 Complete Removal Of Foot Valve ( All Sizes ) From The Pump Suction System And Refitting And Testing After Carrying Out The Requisite Works But Excluding The Cost Of Repairs / Replacements Carried Out On The Foot Valve 96 Polesdismantling Of Pole / Street Light Standard / Strut Embedded In Cement Concrete Foundation Etc. As Required. 97 Erection Of Metallic Pole Of Following Lengths In Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Standard / Suitable Foundation Including Excavation And Refilling Etc. As Required. 98 Above 4.5 Meter And Upto 6.5 Meter 99 Above 6.5 Meter And Upto 8.0 Meter 100 Above 8.0 Meter And Upto 10.0 Meter 101 Above 10.00 Meter And Upto 12.00 Meter 102 Pump Partsfabrication, Providing And Fitting Of Gm Bush To Bell Mouth / Bowl Unit / Stuffing Box / Sleeve, Or Similar As Per Sample Having Finished Weight As Under: 103 Upto 1.0 Kg 104 Extra Per Kg >1.0 Kg Upto 2.5 Kgs 105 Extra Per Kg >2.5Kgs Upto 5.0 Kgs 106 Extra Per Kg > 5.0 Kgs 107 Fabrication, Providing And Fitting Of Gm Bush With Rubber Insert ( Cutlass Bearing ) To Bowl Housing / Bearing Retainer, Etc As Per Sample Having Finished Weight As Under: 108 Upto 1.0 Kg 109 Extra Per Kg >1.0 Kg Upto 2.5 Kgs 110 Extra Per Kg >2.5Kgs Upto 5.0 Kgs 111 Extra Per Kg > 5.0 Kgs 112 Fabrication, Providing And Fitting Of Gm Lantern ( Cooling ) Ring For Stuffing Box As Per Sample Having Finished Weight As Under: 113 Upto 1.0 Kg 114 Extra Per Kg >1.0Kgs Upto 2.0 Kgs 115 Extra Per Kg > 2.0 Kgs 116 Providing And Fitting Of Gm Split Gland As Per Sample Having Finished Weight As Under: 117 Upto 1.0 Kg 118 Extra Per Kg >1.0 Kg Upto 2.5 Kgs 119 Extra Per Kg >2.5Kgs Upto 4.0 Kgs 120 Extra Per Kg > 4.0 Kgs 121 Fabrication, Turning And Finishing ( On Inside And Outside ) Of Stainless Steel ( Aisi-410 Or Is 1030 ) Muff Coupling, Etc. As Per Old Sample Having Finished Weight As Under: 122 Fabrication, Turning And Finishing Of Specified Stainless Steel ( Aisi-410 Or Is 1570 ) Shaft Of Specified Dimensions With End Preparation ( Threaded, Etc. ) , Keyway As Per Old Sample Having Finished Weight As Under: 123 Upto 20.0 Kg 124 Extra Per Kg >20.0 Kg Upto 40 Kgs 125 Extra Per Kg >40Kgs Upto 60 Kgs 126 Extra Per Kg > 60 Kgs 127 Fabrication, Turning And Finishing ( On Inside And Outside ) Of Stainless Steel ( Is 1030 ) Shaft Coupling, Etc. As Per Old Sample Having Finished Weight As Under: 128 Fabrication, Turning, Finishing And Fitting Of Stainless Steel ( Aisi-410 Or Is 1570 ) Shaft Sleeve As Per Old Sample, Etc. Having Finished Weight As Under: 129 Manufacturing, Finishing, Providing Of Ss ( Aisi 410 Or Is 1570 ) Key / Impeller Lock Collet As Per Available Sample And Slot Size. 130 Fabrication, Turning And Threading Of Stainless Steel Shaft Stud As Per Old Sample Etc. 131 Manufacturing, Providing And Fitting Of Ss ( Is 1030 ) Check Nut / Impeller Adjusting Nut With Proper Locking Arrangement As Per Sample Available. 132 Providing And Fitting Of Cast Iron Split Gland As Per Sample: 133 Upto 1.0 Kg 134 Extra Per Kg >1.0 Kg Upto 2.5 Kgs 135 Extra Per Kg >2.5Kgs Upto 5.0 Kgs 136 Extra Per Kg > 5.0 Kgs 137 Fabrication, Providing And Fitting Of Gm / Bronze Impeller Wear Ring / Seal Ring / Sand Collar 138 Upto 1.0 Kg 139 Extra Per Kg >1.0 Kg Upto 2.5 Kgs 140 Extra Per Kg >2.5Kgs Upto 5.0 Kgs 141 Extra Per Kg > 5.0 Kgs 142 Fabrication, Providing And Fitting Of Ci Casing Ring 143 Upto 1.0 Kg 144 Extra Per Kg >1.0 Kg Upto 2.5 Kgs 145 Extra Per Kg >2.5Kgs Upto 5.0 Kgs 146 Extra Per Kg > 5.0 Kgs 147 Fabrication, Providing And Fitting Of Ms Strainer For Suction Bell, Etc. The Strainer Shall Be Applied With One Coat Of Approved Metal Primer And Two Coats Of Anticorrosive Bituminous Paint To Give An Even Shade. 148 Rethreading Of Bolt Hole Using Appropriate Tap Drill 149 Upto M12 Size Hole / Bore 150 > M12 Size Hole / Bore 151 Repairs To Damaged Ss Shaft By Way Of Rebuilding Of Shaft Using High Quality Ss Electrodes ( Ador / Advani / Esab Makes ) And Then Turning The Shaft On Lathe Machine To Remove The Excess Material Deposited And Restore The Original Dimensions And Profile Of The Shaft. 152 Shaft Upto 50Mm Diameter At One Damaged Spot On Shaft Length 153 Extra For Each Subsequent Damaged Spot Over The Corresponding Diameter Upto 50Mm 154 Shaft Of More Than 50Mm Diameter At One Damaged Spot On Shaft Length 155 Extra For Each Subsequent Damaged Spot Over The Corresponding Diameter Above 50Mm 156 Repairs To The Existing Damaged Ss Shaft End By Way Of Rebuilding Using High Quality Ss Electrodes ( Ador / Advani / Esab Makes ) And Then Turning The Shaft On Lathe Machine To Remove The Excess Material Deposited. The Job Includes Threading Or Collar Rebuilding And Facing, Etc. As Per Requirement And Restore The Original Dimensions And Profile Of The Shaft. 157 Shaft Upto 50Mm Diameter At One Damaged Spot On Shaft End 158 Extra For Each Subsequent Damaged Spot Over The Corresponding Diameter Upto 50Mm 159 Shaft Of More Than 50Mm Diameter At One Damaged Spot On Shaft End 160 Extra For Each Subsequent Damaged Spot Over The Corresponding Diameter Above 50Mm 161 Couplingsproviding And Fitting Bush Type Flexible Coupling With Finished Bore And Keyway Of Following Designations ( Preferred Make: Fenner / Lovejoy / Or Equivalent Makes And Designations ) 162 Fbc-1 ( Max. Bore Upto 28Mm ) 163 Fbc-2 ( Max. Bore Upto 30Mm ) 164 Fbc-2A ( Max. Bore Upto 42Mm ) 165 Fbc-3 ( Max. Bore Upto 48Mm ) 166 Fbc-4 ( Max. Bore Upto 65Mm ) 167 Fbc-4A ( Max. Bore Upto 65Mm ) 168 Fbc-5 ( Max. Bore Upto 75Mm ) 169 Fbc-6 ( Max. Bore Upto 95Mm ) 170 Fbc-6A ( Max. Bore Upto 95Mm ) 171 Fbc-6B ( Max. Bore Upto 95Mm ) 172 Fbc-7 ( Max. Bore Upto 15Mm ) 173 Fbc-7A ( Max. Bore Upto 120Mm ) 174 Fbc-8 ( Max. Bore Upto 130Mm ) 175 Fbc-8A ( Max. Bore Upto 135Mm ) 176 Fbc-8B ( Max. Bore Upto 140Mm ) 177 Fbc-9 ( Max. Bore Upto 150Mm ) 178 Fbc-9A ( Max. Bore Upto 160Mm ) 179 Fbc-10 ( Max. Bore Upto 170Mm ) 180 Fbc-10A ( Max. Bore Upto 180Mm ) 181 Fbc-11 ( Max. Bore Upto 190Mm ) 182 Providing And Fitting Of Rubber Bush For Bush Type Flexible Couplings As Under: 183 Fbc-1 Upto Fbc-2A 184 Fbc-3 Upto Fbc-8A 185 Fbc-8B Upto Fbc-11 186 Providing And Fitting Of Pin For Bush Type Flexible Couplings As Under: 187 Fbc-1 Upto Fbc-2A 188 Fbc-3 Upto Fbc-7 189 Fbc-7A Upto Fbc-8A 190 Fbc-8B Upto Fbc-10 191 Fbc-10A Upto Fbc-11 192 Providing And Fitting Flexible Tyre Coupling With Finished Bore And Keyway Of Following Designations As Per Is 14285: ( Note: Number In Designation Indicates Dim. A Approx Tyre Outer Dia ) 193 Tc-104 ( Tc-007 ) 194 Tc-133 ( Tc-009 ) 195 Tc 165 ( Tc-0012 ) 196 Tc-197 ( Tc-0013 ) 197 Tc-211 ( Tc-0014 ) 198 Tc-235 ( Tc-0015 ) 199 Tc-254 ( Tc-0016 ) 200 Tc-279 ( Tc-0017 ) 201 Tc-314 ( Tc-0019 ) 202 Tc-359 ( Tc-0020 / 21 ) 203 Tc-402 ( Tc-0022 ) 204 Tc-470 ( Tc-0023 ) 205 Tc-508 ( Tc-0024 ) 206 Tc-562 ( Tc-0025 ) 207 Tc-628 208 Providing And Fitting Spare Tyre For Tyre Coupling Of Following Designations As Per Is 14285: 209 Tc-104 ( Tc-007 ) 210 Tc-133 ( Tc-009 ) 211 Tc 165 ( Tc-0012 ) 212 Tc-197 ( Tc-0013 ) 213 Tc-211 ( Tc-0014 ) 214 Tc-235 ( Tc-0015 ) 215 Tc-254 ( Tc-0016 ) 216 Tc-279 ( Tc-0017 ) 217 Tc-314 ( Tc-0019 ) 218 Tc-359 ( Tc-0020 / 21 ) 219 Tc-402 ( Tc-0022 ) 220 Tc-470 ( Tc-0023 ) 221 Tc-508 ( Tc-0024 ) 222 Tc-562 ( Tc-0025 ) 223 Tc-628 224 Fastenersproviding Of High Tensile Steel Hexagonal Bolts 225 M6 X 50 226 M8 X 80 227 M10 X 80 228 M12 X 80 229 M14 X 90 230 M16 X 100 231 M18 X 50 232 M18 X 125 233 M18 X 150 234 M20 X 100 235 M22 X 90 236 M22 X 125 237 M22 X 150 238 M24 X 90 239 M24 X 100 240 M24 X 150 241 M27 X 120 242 M30 X 110 243 Providing Of Hexagonal Nuts Of Suitable Pitch With Sizes As Under: 244 M6 245 M8 246 M10 247 M12 248 M14 249 M16 250 M18 251 M20 252 M22 253 M24 254 M27 255 M30 256 Providing And Fitting Of Carbon Steel Fasteners Of Assorted Sizes 257 Fabrication, Providing And Fitting Of Ss / Alloy Steel Hinge Pin For All Types Of Valves, Etc. As Per Old Sample But Excluding The Cost Of Extracting The Old Pin And Dismantling / Reassembling The Valve, Etc. 258 Fabrication & Providing Of New Bronze Body Seat Ring / Bronze Wedge Facing Ring / Bronze Stem Nut / Float Guide As Per Sample For Various Valves But Excluding Cost Of Dismantling The Valve Parts 259 Upto 1.0 Kg 260 Extra Per Kg >1.0 Kg Upto 2.5 Kgs 261 Extra Per Kg >2.5Kgs Upto 4.0 Kgs 262 Providing And Fitting Of Rubber Gasket For Various Types Of Valves 263 Providing Of Jute / Hemp Gland Packing 264 Fabrication & Providing Of New Ss Stem Nut / Stem-Spindle / Pinion / Pinion Shaft / Stub Shaft ( Aisi-410 Or Is 6603 ) For Sluice / Butterfly Or Other Type Of Valve As Per Old Sample 265 Upto 20.0 Kg 266 Extra Per Kg >20.0 Kg Upto 40 Kgs 267 Extra Per Kg >40Kgs Upto 60 Kgs 268 Extra Per Kg > 60 Kgs 269 Foot Valvefabrication, Providing And Fitting Of Ci Disc Plate As Per Old Sample 270 Providing Of Leather Disc Face Washer For Foot Valve 271 Labour For Fitting Of Washer To Foot Valve Including Removal Of Foot Valve From Suction Line, Extraction Of Old Damaged Washer, Fitting Of New ( Available ) Washer And Refitting Of Foot Valve To Suction Line. 272 Providing And Fitting Of Screwed Type Gm Foot Valve Conforming To Is-4038 Of Nominal Size: 273 15Mm 274 20Mm 275 25Mm 276 32Mm 277 40Mm 278 Flangesproviding And Welding Of Steel Plate Flanges Of Nominal Pressure Rating 1.0Mpa As Per Is 6392 With Nominal Sizes As Under: 279 32Mm 280 40Mm 281 50Mm 282 65Mm 283 80Mm 284 100Mm 285 125Mm 286 150Mm 287 200Mm 288 250Mm 289 300Mm 290 350Mm 291 Providing And Welding Of Steel Plate Flanges Of Nominal Pressure Rating 1.6Mpa As Per Is 6392 With Nominal Sizes As Under: 292 32Mm 293 40Mm 294 50Mm 295 65Mm 296 80Mm 297 100Mm 298 125Mm 299 150Mm 300 200Mm 301 250Mm 302 300Mm 303 350Mm 304 Providing And Welding Of Steel Plate Blind Flanges As Per Is 6392 Of Nominal Pressure Rating 1.6Mpa With Nominal Sizes As Under: 305 50Mm 306 65Mm 307 80Mm 308 100Mm 309 125Mm 310 150Mm 311 200Mm 312 250Mm 313 300Mm 314 350Mm 315 Gasketproviding Of Natural Rubber Gasket For Flanged Joints With Nominal Sizes As Under: 316 32Mm 317 40Mm 318 50Mm 319 65Mm 320 80Mm 321 100Mm 322 125Mm 323 150Mm 324 200Mm 325 250Mm 326 300Mm 327 350Mm 328 400Mm 329 Providing And Fiiting Of C Classonforming To Is: 1239 Of Length 10 Rft Into The 200 / 250 / 300 Mm Casing Dia. Production Well 330 Dn 50C ( Heavy ) Pipe 331 Dn65c ( Heavy ) Pipe 332 Dn80c ( Heavy ) Pipe 333 Providing / Supplying And Fitting Of G.I Flanged Rising Main As Per Requirment 334 Dn 50C ( Heavy ) Pipe 335 Dn65c ( Heavy ) Pipe 336 Dn80c ( Heavy ) Pipe 337 Dn100c ( Heavy ) Pipe 338 Dn125c ( Heavy ) Pipe 339 Dn150c ( Heavy ) Pipe 340 Dn 200C ( Heavy ) Pipe, 6Mm Thick 341 Dn 50B ( Medium ) Pipe 342 Dn65b ( Medium ) Pipe 343 Dn80b ( Medium ) Pipe 344 Dn100b ( Medium ) Pipe 345 Dn125b ( Medium ) Pipe 346 Dn150b ( Medium ) Pipe 347 Providing / Fitting Of New Bearing As Under: ( Make: Skf Imported / Equivalent Imported ) 348 No. 3210 A / C3 349 No. 3212 A / C3 350 No. 3213 A / C3 351 No. 3309 A / C3 352 No. 3313 A / C3 353 No. 51310 354 No. 51312 355 No. 51314 356 No. 51320 357 No. 6014 358 No. 6220 359 No. 6314 360 No. 6315 361 No. 6320 362 No. 6324 363 No. 6406 364 No. 6408 365 No. 6410 366 No. 6411 367 No. 6412 368 No. 6415 369 No. 6418 370 No. Nu322 Ecj 371 No. Nu324 Ecj 372 No. 29322 E 373 No. 29324 E 374 No. 29328 E 375 No. 29330 E 376 No. 29424 E 377 No. 29426 E 378 Providing / Fitting Of New Bearing As Under: ( Make: Schaeffler ( Fag ) Imported / Equivalent Imported ) 379 No. 6220 380 No. 6317 381 No. 6318 382 No. 6319 383 No. 6320 384 No. 29322-E1-Xl 385 29324-E1-Xl 386 No. 29326-E1-Xl 387 No. 29328-E1-Xl 388 No. 29330-E1-Xl 389 No. 29424-E1-Xl 390 No. 29426-E1-Xl 391 Providing / Fitting Of New Bearing As Under: ( Nbc / Arb / Zkl / Equivalent Domestic ) 392 No. 3210 393 No. 3212 394 No. 3213 395 No. 3306 396 No. 3307 397 No. 3309 398 No. 3310 399 No. 3311 400 No. 3312 401 No. 3313 402 No. 51310 403 No. 51312 404 No. 51314 405 No. 51320 406 No. 51322 407 No. 6014 408 No. 6028 409 No. 6217 410 No. 6220 411 No. 6305 412 No. 6306 413 No. 6307 414 No. 6308 415 No. 6309 416 No. 6310 417 No. 6311 418 No. 6312 419 No. 6313 420 No. 6314 421 No. 6315 422 No. 6320 423 No. 6322 424 No. 6406 425 No. 6408 426 No. 6410 427 No. 6411 428 No. 6412 429 No. 6415 430 No. 7312 431 Providing And Fitting Of New Plummer Block / Bearing Housing With Designation As Under: ( Prefered Makes: Masta / Sibco ) 432 S 507 433 S 508 434 S 509 435 S 510 436 S 511 437 S 512 438 S 513 439 S 515 440 S 516 441 S 517 442 S 518 443 S 519 444 S 520 445 S 522 446 S 524 447 Hiring Of Portable Diesel Engine Operated Pumpset For Dewatering Around Workspace Of Pipes, Etc. Excluding Fuel Charges 448 Structural Steel Work In Single Section Fixed Without Connecting Plate Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 449 Structural Steel Work Welded In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 450 Cutting Charges Of Mild Steel Pipes / Plates Including Cost Of Consumables, Etc.But Excluding The Cost Of Transportation Charges Of Equipment To Site 451 Using Grinder 452 By Gas Cutting 453 Welding Charges Of Prepared Mild Steel Sections, Etc Including Cost Of Consumables, Etc. But Excluding Carriage Of Equipment To Site, Etc. 454 By Electric Welding 455 By Gas Welding 456 Hiring Of Mobile Crane Upto 5 Ton Capacity 457 Hiring Of Excavator For Earthwork Excavation. 458 Wtpproviding And Fitting Of 5Kg / Cm2, 12Mm Connection Pp / Pe Filter Nozzle On Bed Of Pressure Filter Vessel 459 Providing And Laying Of Filter Media ( Filter Gravel And Course Sand ) Of Specific Size And Grade In 5000 / 6000 Gph Pressure Vessel, Duly Washed And Free From Dust, Dirt, Loom And Any Other Material Or Suspension. The Job Includes Carriage Of Filter Media Including All Loads And Lifts. The Media Shall Be Laid In Different Layers Of Specific Size And Grade From Bottom To Top Over The Filter Bed Plate. The Bottom Layer Is To Be Laid Without Tilting Or Damaging The Pressure Nozzles. 460 Providing Of Grease ( Industrial Type ) Conforming To Is 7623 ( Preferred Makes: Hpcl Lithon-3 / Indian Oil Servogem-3 / Or Equivalents Of Bpcl; Castrol; Caltex ) 461 Providing Of Ap3 Grease ( All Purpose Type ) ( Preferred Makes: Hpcl / Indian Oil / Bpcl / Castrol / Caltex ) 462 Providing Of Mineral Oil For Bearing Lubrication ( Preferred Make: Indian Oil Servo / Hpcl / Bpcl Mak / Shell Mobil ) 463 Providing Of Graphited Natural Fibre Packing For Pumps, Etc. ( Preferred Make: Champion Style-3116 Or Equivalent ) 464 Excavating Trenches Of Required Width For Pipes, Cables, Etc In All Kinds Of Soil Including Excavation For Sockets And Dressing Of Sides, Ramming Of Bottoms, Depth Upto 1.5 M, Including Getting Out The Excavated Soil, And Then Returning The Soil As Required, In Layers Not Exceeding 20 Cm In Depth, Including Consolidating Each Deposited Layer By Ramming, Watering, Etc. And Disposing Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M 465 Pipes, Cables Etc, Not Exceeding 80 Mm Dia. 466 Pipes, Cables Etc. Exceeding 80 Mm Dia. But Not Exceeding 300 Mm Dia 467 Pipes, Cables Etc. Exceeding 300 Mm Dia But Not Exceeding 600 Mm Dia 468 Pipes, Cables Etc. Exceeding 600 Mm Dia But Not Exceeding 1200 Mm Dia 469 Extra For Excavating Trenches For Pipes, Cables Etc. In All Kinds Of Soil For Depth Exceeding 1.5 M, But Not Exceeding 3M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre ) . 470 Extra For Excavating Trenches For Pipes, Cables, Etc, In All Kinds Of Soil For Depth Exceeding 3 M In Depth, But Not Exceeding 4.5 M. ( Rate Is Over Corresponding Basic Item For Depth Upto 1.5 Metre. ) 471 Pumping Out Water Caused By Springs, Tidal Or River Seepage, Broken Water Mains Or Drains And The Like. 472 Gravel Packing In Tube Well In Accordance With Is: 4097, Including Providing Gravel Fine / Medium / Coarse In Required Grading And Sizes As Per Actual Requirement All Complete As Per Direction Of Engineer-In-Charge. 473 Painting For Repaired Pumps / Steel Work 474 Removing Of Old Paint, Rust, Foreign Contaminants Etc. From Pump Body ( Internal & External ) , Structural Work ( Gratings, Any Type Of Frame Work, Etc. ) Motor Body Or Other Equipment By Scrapping, Cleaning, Rubbing, Chipping By Any Means & Preparing The Surface To Receive New Coat Of Paint. The Cost Including Cost Of Materials, Labours, Scaffolding Etc. To Complete The Job At Site As Per Direction Of Engineer In Charge. 475 Providing & Application Of Primer ( Epilux-610 Grey Or Any Other Approved Brand ) On Cleaned Surface Of Pump Body ( Internal Or External ) / Motor Body / Structral Framework / Gratings, Etc. Including Thinner ( Epilux - 844 Or Any Other Approved Brand ) Brush & Other Materials As Required, Labours, Scaffolding Etc. To Complete The Work At Site As Per Direction Of Engineer In Charge.For 1St Coat Of Primer ( Manual Painting ) 476 Cost For Supplying & Application Of Coal Tar Epoxy Paint ( Epilux-5 Or Any Other Approved Brand ) On Cleaned Surface Of Pump Body / Motor Body / Any Stuctural Framework, Gratings Including Thinner ( Epilux-844 Or Any Other Approved Brand ) & Other Materials As Required, Labours, Brush, Painting Equipments Etc. To Complete The Work At Site As Per Direction Of Engineer In Charge. 477 For 1St Coat Of Paint ( Manual Painting ) 478 For 2Nd Coat Of Paint ( Manual Painting ) 479 Painting ( Two Or More Coats ) On Pipes And Fittings With Black Anticorrosive Bitumastic Paint Of Approved Brand Over And Including A Priming Coat Of Ready Mixed Zinc Chromate Yellow Primer 480 Painting ( Two Or More Coats ) With Synthetic Enamel Paint Of Approved Brand Over Cleaned / Prepared Surfaces. 481 Hiring Charges Of Electrician ( For Troubleshooting / Revamping Of Existing Electrical Fitting, Etc. Exclusive Of Specified Works ) : 482 Hiring Charges Of Labourer For Support Of Electrician
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Jammu And Kashmir View Result →
29.
Public Administrative Department #10251157 Price Bid
Providing Paver Block Road At Sapputhaikkal Street And Construction Of Strom Water Drainage At Poonga Nagar In Thittachery Town Panchayat , Ordinary Soil Ss20a Earth Work Excavating And Depositing On Bank With Initial Lead Of 10M And Initial Lift Of 2 M In M-Sand, Silt Or Other Loose Soil, Wet Sand Or Silt Not Under, Light Black Cotton Soil Sandy Loam And Ordinary Soil Including Excavated Earth Ss.20.A Morth No.301 , Cement Concrete Of Mix 1:4:8 (One Cement Four And Eight Aggregates) Using 40Mm Gauge Hard Broken Including Cost Conveyance Of All Materials To Site Including Labour Charges, Transporting And Placing In Position Including Shoring, Strutting Forming Protective Bunds, Cofferdams Bailing Out Of Water Labour For Mixing Compacting, Finishing And Curing, Working At Depths, Tools And Plants And Incidental Charges Such As Sheeting, Shoring And Bracing And Their Subsequent Removal Etc., Complete As Per Standard Specification. , Supplying & Erecting Centering For Sides & Soffiots Including Necessary Supports & Strutting Upto 3.29M Height For Plane Surfaces In All Floors With All Cross Bracings Using Mild Steel Sheets Of Size 90 X 60Cm & 10 Gauge Stiffened, Welded With Steel Angle Of Size 25 X 25 X 3Mm For Boarding Laid Over Silver Oak Joists(Country Wood) Of Size 10 X 6.5Cm Spaced @ About 90Cm C/C And Supported By Casurina Props Of 10 - 13Cm Dia. Spaced @ 75Cm C/C Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. Rate For 10M2.For The Following Items.(Rcc Floor Slab, Roof Slab, Rectangular/ Square, Tee/ Ell Beams, Lintels, Staircase Waist Slabs, Landing Slabs, Landing Beam, Portico Beam Etc., ). , Grade Beam , Supplyingandfabrication Of Steel And Placing In Position Ms / Ribbed Tor Steel Grills For Rcc Works As Per Design Given Including Cost Of Steel And Gi Binding Wire In Floors Etc,. Complete Complying With Standard Specification In Force And As Directed By Department Officials.- , Providing And Laying In Position Standardised Concrete Mix M-20 Grade In Accordance With Is 456 - 2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cement Contenet Of 325Kg/ Cum And Maximum Water Cement Ratio Of 0.55 Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is 9103 To Accelerate, Related Setting Of Concrete, Improve Workability Without Imparing Strength And Durability With About (5.0Cum), 7730Kg Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cum), 5156Kg Of 10 - 12Mm Machine Crushed Stone Jelly And With About (4.79Cum) 7670 Kg Of Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges Centering And Shuttering But Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc And Providing Fixtures Like Fan Clamps In The Rcc Floor / Roof Slabs Wherever Necessary Without Claiming Extra Cost Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers - The Coarse And Fine Aggregates To Be Used Should Comply With The Requiremnents Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials) - , Plain Cement Concrete 1:2:4 (One Cement, Two Crushed Stone Sand (M- Sand) And Four Coarse Aggregates) Using 20Mm Size Iss Hbg Metal Including Cost And Conveyance Of All Materials To Site And Including For The Mixing, Laying And Labour Chargesetc., Complete As Per Standard Specification , Providing Granolithic Floor Finish Of The Following Thickness With Plain Cement Concrete 1:2:4 (One Cement, Two M.Sand And Four Aggregate) Using 10 To 12Mm Gauge Hard Broken Stone Jelly Including Laying, Finishing And The Top Rubbed Smooth With Power Trawl, Thread Lining, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. (The Rate Is Inclusive Of Necessary Planking For Panellingwherever Necessary And As Directed By The Departmental Officers) 40Mm Thick , Providing And Laying, Spreading And Compacting Graded Stone Aggregates To Wet Mix Macadam To A Required Thick Specification Including Premixing The Materials With Water At Omc In Mechnanical Mix Plant Carriage Of Mixed Material By Tipper To Site Laying In Uniform Layers With Pavers In Sub Base/Base Course On Well Prepared Surface And Compacting With Vibratory Roller To Acheive The Desired Density Including Cost Of Material, Labour Charges, Rentals For Machinery, Fuel And All Other Incidental Charges Etc., Complete As Per Clause 406 Of Morth Rev-5 , Supplying And Laying Of Interlocking Paver Block Stone 63Mm Thickover A Base Layer Ofstone Dust Filling Incl. Cost Of Materialslaying And Labour Charges Etc Complete Complying With The Standardspecification And As Directed By The Departmental Officers , Manufacturing, Supplying And Fixing Precast Reinforced Cement Concrete Slabs Of Following Thickness In Rcc 1:11/2:3 (One Cement, One And Half Sand And Three Aggregates), Using Following Hbgs Jelly Including Cost Of Reinforcement Steel In Position But Including Cost Of Moulding Charges, Casting Of Slab, Finishing, Curing And Fixing In Position In All Floors Etc., Complete Complying With Standard Specification And As Directed.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
31.
Drinking Water Supply and Sanitation #10236715 Price Bid
Augmentation Cum Reorganization Of Aapni Yojana Phase I Churu Bisau Feeder Water Supply Project Including 10 Years O And M District Churu.- 1 Part A : Cost Estimate For Pipeline Works 2 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 3 75 Mm Dia 4 90 Mm Dia 5 110 Mm Dia 6 125 Mm Dia 7 140 Mm Dia 8 160 Mm Dia 9 180 Mm Dia 10 200 Mm Dia 11 225 Mm Dia 12 100 Mm Dia 13 150 Mm Dia 14 200 Mm Dia 15 250 Mm Dia 16 300 Mm Dia 17 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-7 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 18 100 Mm Dia 19 150 Mm Dia 20 200 Mm Dia 21 250 Mm Dia 22 300 Mm Dia 23 Providing, Lowering, Laying In Trenches, Aligning, Fixing In Position And Jointing Ductile Iron ( Di ) Isi Marked K-9 Grade S&S Pipes As Per 15:8329-2000 ( Amended Upto Date ) , With Internal Cement Mortar Lining Suitable For Potable Water With Rubber Ring ( Epdm ) Joints As Per Is: 5382- 1985 Including All Taxes ( Central And Local ) , Transportation And Freight Charges, Inspection Charges, Loading / I.I Unloading Charges, Including Cost Of Labour And Material, Specials ( Tee, Bend Etc. ) Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In Charge. ( Excluding Earth Work ) Note : Providing And Fixing Of All Requisite Specials As Per Drawing, Design And Layout Are Inclusive In Rm Measurement Of The Item And Shall Not Be Paid Separately. 24 150 Mm Dia 25 Providing, Lowering, Laying And Jointing In Trenches, Standard Lengths Hdpe Pe- 80 Pn-6 Isi Marked Pipes As Per Is-4984:1995 ( Ammended Upto Date ) With Neccessary Jointing Material Like Mechanical Connectors, I.E. Thread / Insert Joint / Quick Release Coupler Joint / Compression Fitting Joint Or Flanged Joint And Specials Jointing Pipe By Butt Fusion / Electro Fusion Welding Method, Including All Taxes, Transportation And Freight Charges, Inspection Charges, Loading / Unloading Charges, Stacking Of Pipes, Including Cost Of Labour And Material, Specials ( Tee, Bends Etc. ) , Satisfactory Hydraulic Testing, Disinfection Etc. Complete As Per Technical Specifications And Direction Of Engineer-In-Charge Of Following Class And Diameter. ( Excluding Earthwork ) 26 75 Mm Dia 27 90 Mm Dia 28 110 Mm Dia 29 125 Mm Dia 30 140 Mm Dia 31 160 Mm Dia 32 180 Mm Dia 33 200 Mm Dia 34 225 Mm Dia 35 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Combination Air Release Valve Kinetic Type With Single Chamber Housed Double Orifice And Have 3 Functions, Large Air Exhaust, Small Air Venting And Large Air Intake During Vacuum Of Pipeline Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications:Governing Standard - Awwa C512 , Body And Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float & Internal Trim: Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbrdrilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside Fasteners - Cs / Galvanised Steel , Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, Big Orifice Size Should Be Equal Or Larger Than The Inlet Flange Bore, For Fully Comply With Awwa C512. ) , Valve Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge.Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. 36 50 Mm Dia 37 Construction Of Air Valve Pillar For Fixing Of Air Valves 38 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 39 100 Mm Dia 40 150 Mm Dia 41 200 Mm Dia 42 Providing, Lowering, Aligning, Fixingin Positionin Pipeline, Cid / Fsluicevalvesof Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss, Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxic- Suitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitablesupport Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Manually Operated Ci Sluice Valves Of Class Pn 1.0 Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 43 80 Mm Dia 44 100 Mm Dia 45 125 Mm Dia 46 150 Mm Dia 47 200 Mm Dia 48 250 Mm Dia 49 300 Mm Dia 50 Cosntruction Of Valve Chamber For Sluice Valves, Flow Control Valve And Butterfly Valve As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 51 Type - A ( 80 Mm To 100 Mm Dia ) 52 Type - B ( 125 Mm To 200 Mm Dia ) 53 Type - C ( 250 Mm To 350 Mm Dia ) 54 Construction Of Village Transfer Chamber As Per Approved Design, Drawing & Specification Given For Material Of Construction And Completion Of All Works Of Installation Of Sluice Valves, D.Joints, C.I. Pipes, Specials ( Excluding Supply ) Etc. Complete In All Respect To Achieve The Work As Given In The Scope Of Work. 55 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 56 100 Mm Dia 57 150 Mm Dia 58 200 Mm Dia 59 250 Mm Dia 60 300 Mm Dia 61 Construction And Commissioning Of Rcc Intze Type Over Head Service Reservoir Of Following Capacity And Staging As Per The Scope Of Work And Technical Specifications, Consisting Of The Following Main Activities: - 62 A ) Topographic Survey, Preparation Of Site Contour Plan, Conducting Sbc Testand Its Approval From Departmentbefore Construction. Submission And Approval Of Concrete Mix Design And Water Quality Test Report For Water To Be Used In Construction. B ) Excavation In All Types Of Soil, Pcc Below Foundation, All Rcc Work, Plinth Protection All Around The Structure Including All Material, Labour, Shuttering, Scaffolding Etc.C ) Ohsr Shall Be Provided With Adequate Plinth Protection All Around The Structure In A Width Starting From Edge Of Structure At Gl And Extending At Least Up To 1.0M Beyond The Edge Of Outer Most Projection Of Ohsr.The Plinth Protection Shall Consist Of 150Mm Thick Pcc In M-15 Grade Concrete Laid Over 150Mm Thick Layer Of Compacted Soil.D ) Providing And Applying Two Coats Of Food Grade Epoxy Paint On The Inside Surface On The Top Dome, Edge Beam And 600 Mm Height Of The Vertical Wall.E ) Conducting Successfully Hydro Test And Water Tightness Test As Per I.S. Code.F ) Providing And Applying Three Coats Of Anti-Carbonation Paint On The Top Surface Of The Top Dome.G ) Providing And Applying Three Coats Of Cement-Based Paint On The External Surface Of The Container, Balcony, Cone Wall, Columns & Beams Etc..H ) Providing And Fixing Ss-304 Ventilator, Ss 304 Manhole Frame And Cover And Ss-304 Ladder From Top Dome / Slab To Bottom Dome / Slab Inside Container. I ) Providing And Fixing Of Ms Section Ladder From The Last Landing To Balcony Having Railing All Around It And Ms Ladder With Safety Cage From Balcony To Top Dome / Slab.J ) Providing And Fixing Water Level Indicator ( Float Type ) . 63 K ) Providing And Fixing Of Hand Railing All Around The Balcony, Top Dome And Staircase Consisting Of 25Mm Diameter Class-B Gi Pipe In Two Rows And 1000 Mm High, 50X50x6mm Angle Iron Vertical Post At A Maximum Spacing Of 1500Mm Centres.L ) All Ms Parts To Be Painted With Two Coats Of The Enamel Paint Over The Primer Coat Of Red Oxide.M ) Providing And Fixing Of 150Mm Wide Pvc Water Bar For The Construction Joints In The Container ( Vertical Wall & Cone Wall ) .N ) Providing One Aluminium Portable Ladder Of Appropriate Length To Access First Landing ( 3.5 To 4.5M Above Gl ) From Ground.O ) Lighting Arrestor Consisting Of Providing And Fixing Of 2 Nos.Of Chemical Earthing And Connecting It To The Conical Cover Of Ss Ventilator With Two Separate Gi Strips Of 50Mmx3mm.P ) Ci / Di Puddle Collar Shall Be Fixed In The Bottom Dome / Slab For Connecting Inlet, Outlet, Overflow And Washout Pipe Of The Reservoir.Q ) Painting The Name Of The Scheme And Other Details On The Reservoir, And Any Other Work Related To Structure As Per The Directions Of Engineer-In- Charge, Technical Specification And Scope Of Work.R ) Inlet, Outlet, Overflow, Washout Pipes And Valves Are Not Included In This Work, Provision For The Same Shall Be Taken Separately. 64 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 18 M 65 100 Kl 66 150 Kl 67 Rates For Rcc Ohsr, Sbc 10 T / Sqm, Seismic Zone-Ii & Staging 20 M 68 100 Kl Each ( 100 X 2 Nos. ) 69 200 Kl Each ( 200 Kl X 3 Nos. ) 70 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 71 100 Mm Dia 72 150 Mm Dia 73 200 Mm Dia 74 Construction Of Boundary Wall Of Brick / Stone Masonary As Per Enclosed Ga Drawing, Scope Of Work And Technical Specifications Complete Work In All Respect. Brief Details Of Boundary Wall Parameter Is As Below:1. Depth Of Foundation- 900 Mm.2. Pcc In M-10, Width -900 Mm And Thickness 100 Mm, 3. Section Of Foundation Above Pcc W-600 Mm, D-450Mm, W- 450Mm, D-450 Mm.4. Superstructure Work: Stone Masonary W-300, Height-1650 Mm, / Brick Work W-230 Mm, Height- 1650 Mm.5. Cement Mortar Pointing On Stone Masonary And Cement Mortar Plaster 20 Mm Thick On Brick Masonary In Cm 1:6.6. Expansion Joint Shall Be On Every 30 Mtr.7. On Top Of Wall There Shall Be Cc Coping 75 Mm Thick ( 1:2:4 ) Shall Be Provided.8. Pillar For Main Gate 350X350 Mm In Size Is Part Of Boundary Wall.9. Cement Paint Of Approved Colour In 3 Coat Shall Be Done. 75 Providing And Fixing Steel, Gate, Grating And Grills Made Of Angles, Tees, Square Bars, Flats Or Black Pipe With Hold Fast And Fitting Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide And Two Coat Of Enamal Paints. 76 Dismantling Of Cement Concrete Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Cutting The Peripheral Edge By Cc Cutter, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shallbe Made For Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks As Per Technical Specification And Scope Of Work. 77 Providing And Laying In Position Cement Concrete M10 Grade Nominal Mix 1:4:8 ( 1 Cement : 4Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size ) In Base Course Complete Including All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. 78 Providing And Laying In Position Cement Concrete In Specified Grade Over Prepared Base Course Complete Including Finishing, Curing, All Material, Labour, Machinery, Lighting, Guarding For Road Restoration Work In Trenches Of Pipe Line And Chamber Work. Measurement For Cc Work To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Made Be Made For Trench Width More Than Specified, Complete Work As Per Technical Specification And Scope Of Work. M20 Grade Nominal Mix1: 1.5: 3 ( 1 Cement : 1.5 Coarse Sand : 3 Graded Stone Aggregate 20Mm Nominal Size ) . 79 Dismantling Of Flexible Pavement For Pipe Lineand Chambers By Mechanical Means Using Pneumatic Tools, Breaking To Pieces Not Exceeding 0.02 Cum In Volume And Stock Piling At Designated Locations And Disposal Of Dismantled Materials Up To A Lead Of 1000 Meters. Measurement For Dismantled Trench To Be Madeas Per Standard Trench Width Specified In Tender Document And No Extra Payment Shall Be Madefor Trench Width More Than Specified, Re-Handling Of Material / Earth To Complete The Tasks Per Technical Specification And Scope Of Work. 80 Bituminous Courses 81 Granular Courses 82 Provision For Restroration Of Bitumen Road After Laying & Jointing Pipe Line As Per Direction Of Engineer In Charge 83 Provision Forrestoration Of Wbm Road Cutting As Per Specifications. 84 Total Length Of Canal Corssing During Laying Of Pipe At Various Locations 85 Providing Service Connection As Per Technical Specification And Standard Drawing As Per Relevant Is Code ( Ammended Up To Date ) From All Kind Of Water Mains Up To Consumer Meter / Premises ( Complete Job ) . This Job Includes Digging Out Suitable Size Of Pits And Trench For Laying Service Line In All Kinds Of Soil Including Demolishing Of Cement Concrete, Wbm, Black Top Etc. Of All Thickness; Cutting Of Cc Road / Jhiri By Using A Concrete Cutter Machine; Depositing And Refilling Of Pit & Jhiri Watering And Ramming / Compacting In Layers And Disposal Of Surplus Excavated Soilas Directed With In A Lead Of 50 Meter; Providing And Fixing Of All Fitting Duty Approved In Accordance With Iso / Dtr 9080 As Per Specification For Portable Water Including Approved Make Of Ms / Pvc Clamp With Saddle Piece, Gunmetal Ferrule 4.0 Mm ( Isi Make ) , Valve ( Is: 778 ) And Specials With Mdpe Pipe Pe 80 Pn 12.5 As Per Iso 4424 Below Ground Level And P&F Gi Pipe 15 Mm Dia Class B ( Isi Mark ) Above Ground Level In The Premises For Fixing Tap ( Max. Length2.0 Mtr. ) , P&F A 15 Mm Bib Cork With Foam Flow Chrome Plated With Complete Brass Body Including Brass Handle Having Good Quality With Wt 300 To 325 Gm, Including Accessories With Flushing , Cleaning, Disinfecting And Testing Of Pipeline Complete Required For Making Of Service Connection Complete In All Respect Including Labour Charges. In Addition To The Ferrule, An Orrifice Of 4.0Mm Dia Should Also Be Provided In The Service Line At The Entry Pointy Of ConsumerS Property In Such A Way That It Should Be Accessible For Inspection To Vwsc, Phed And Any Other Authority Which Woyld Like To Inspect As And When Required. The Service Line Should Be Laid Atleast 45 Cm Below Ground Level, Except In Case Of Concrete / Bituminous Raods Where Minimum Depth Shall Be 20Cm. For Details Specifications Of Mdpe Pipes Please Refer Technical Specifications Of Bid Document. General Specifications Of Mdpe Pipes Shall Be As Under: The Raw Material Shall Be Virging Pe 80 Blue Compound And Comply With The Requirement Of Iso / Directive Of Testing Material : 9080 With Minimum Required Strength Of 8 Kg / Sq.Cm. ; The Raw Material Shall Be Food Grade Quality ; Ressure Rating Shall Be 12.5 Bar ; The Pipes Shall Bear Iso Marking 86 Removing& Re-Fixing Of Precast Concrete Interlocking Blocks By Manual, Stacking Of Serviciable & Non Serviceable Material Separately. Disposal Of Dismantled Material Lead Up To 50 Mtr. The C.C. Interlocking Paving Blocks Be Laid On Average 25 Mm Thick Bed Of Coarse Sand And The Joints To Be Filled With Fine Sand. Laying Procedure On Compacted Sub Base As Defined. Complete Job Is To Be Executed As Per The Directions Of Engineer In Charge. The Rates To Be Inclusive Of Fixing Of Minimum 70 Percent Reusable Precast Concrete Interlockingblock And Cost Of Required New Precast Concrete Interlocking Block Against Damaged, Including Alllead And Lift As Per Technical Specifications. ( Interlocking Blockmanufactured By Fully Computerized Automatic Stationery Hydraulic Vibro Pressed Machine & Full Computerized Automatic Batching Plant Of Class A-1 As Per Bs:6717-2001. Tensile Splitting Strength And Breaking Load As Per Bs: 6717-2001Colour: Grey Cement Natural Colour. Variation In Dimension : Less Than 1.6 Mm Variation In Thickness: Less Than 3.2 Mm ) 80 Mm Thick 87 Add Extra Over Item No 1.21 & 1.22 For Providing20 Mm Pe80 Pn 16 As Per Iso 4427 Mdpe Pipe Including Excavation, Providing, Laying & Jointing Of Service Line Above 5.00 Mtr. 88 Supply Laying And Pushing Of Ms Casing Pipe Of Specified Thickness Approved By Concerned Department Authority By Trenchless Method Adopting Any Suitable Technology Below Ground At Required Depth Under Running Traffic Condition As Per Highway / Railway Standard Including Carrying Out Survey Work At The Job Site For Determining Underground Cable Trenches Like Telephone, Cable, Water & Sanitary Lines And Resistivity Test For Finding The Soil Strata Using Necessary Equipments For Completion Of Works, Mobilizing Of Machineries And Specialized Crew At The Job Site Complete In All Respect, Including Excavation Of Driven Pit And Exit Pit ( Up To 3 Meter Depth ) With Proper Protection At These Sites With Shoring Sheets And Ismb. Providing Ms Cutting Edges For Front Shield And Constructing Thrust Bed At Designated Level. Necessary Dewatering And Providing Concrete Foundation At The Base Of The Driven Pit, Pvc / Rubber Saddle As Per The Requirement Of Highway / Railway Authority, Crane For Handing Of Pipe And Any Other Machinery, Tools, And Tackles Required, Construction Of Temporary Works As Per Design, Drawing And Method As Per Approved Byauthority Specification And The Direction Of The Engineer.Apply Corrosion, Resistant, Protection On Inside And Outside Of Casing Pipeas Per Technical Specification. 89 300 Mm Dia 8 Mm Thick Casing Pipe With Protective Coating. 90 Part B : Pump House & Cwr 91 Fabrication, Supply Of Flanged / Plain Ended Ms Pipe Made From Ms Sheet Strips Of Relevant Is Specification Of Approved Thickness By Welding, Lowering, Laying, Aligning, Fixing In Position At All Level / Depths In Trenches Complete Excluding Flanged Jointing Wherever ( Required ) Including All Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer. 92 Ms Pipe Upto 600 Mm Dia ( With Minimum 5Mm Thickness Sheet 93 Ms Pipe Above 600Mm Dia ( With Minimum 6.3Mm Thickness Sheet ) 94 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6 95 100 Mm Dia 96 125 Mm Dia 97 150Mm Dia 98 200 Mm Dia 99 250 Mm Dia 100 300 Mm Dia 101 450 Mm Dia 102 500 Mm Dia 103 600 Mm Dia 104 700 Mm Dia 105 900 Mm Dia 106 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing Ci Dismantling Joint ( Suitable For Sluice Valves Etc. ) As Per Is Specifications Complete Of The Following Sizes Including All Jointing Material, Cost Of All Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 107 100 Mm Dia 108 125 Mm Dia 109 150 Mm Dia 110 200 Mm Dia 111 250 Mm Dia 112 300 Mm Dia 113 450 Mm Dia 114 500 Mm Dia 115 600 Mm Dia 116 900 Mm Dia 117 1000 Mm Dia 118 Cosntruction Of Valve Chamber For Sluice And Butterfly Valves As Per Approved Drawing And Specifications To The Satisfaction Of Engineer-In-Charge 119 Valve Chamber ( 80 Mm To 100 Mm Dia ) 120 Valve Chamber ( 500 To 600 Mm ) 121 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Di D / F Resilient Seated ( Soft Seated ) Short Body Pattern Type Double Eccentric Butterfly Valves Of Approved Make Of Following Class & Dia Complete Confirming To Bs En 593 / Bs 5155 / Is 13095 / 1991 Amendedup To Date And Of Following Specifications: Body, Disc And End Cover Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Face To Face Dimensions As Per Din 3202 F4 / Is 13095Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Both Body And Disc Inside And Outside. Disc Seal Ring Of Epdm / Neoprene ( Food Grade Quality ) And Disc Seal Retaining Ring Of Ss / Cs. Shaft Of Ss- Aisi- 304 / 316 & Shaft Bearings-Bronze / Ptet Or Teflon With Epdm / Nbr O Ring Seal, Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic Including Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipeline As Per Technical Specification & As Per Direction Of Engineer-In-Charge.Class Pn 1.6, Motorised Operatednote: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 122 100 Mm Dia 123 150 Mm Dia 124 250 Mm Dia 125 450 Mm Dia 126 500 Mm Dia 127 600 Mm Dia 128 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.6 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer. 129 100 Mm Dia 130 125 Mm Dia 131 150 Mm Dia 132 250 Mm Dia 133 450 Mm Dia 134 500 Mm Dia 135 Providing, Lowering, Laying, Aligning, Fixing In Position And Jointing In Pipe Line, Di Dual Plate Check Valves Of Pn 1.0 Rating Of Following Dia ( Including Jointing And Jointing Material ) , Including All Material, Labour, Testing And Commissioning As Per Technical Specificationsand As Per Direction Of Engineer. 136 600 Mm Dia 137 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq 138 295.08 Lps, 59 M Head 139 295.08 Lps, 80 M Head 140 274.12 Lps, 61 M Head 141 Providing And Fixingat Site With Necessary Packing, Horizontal Centrifugal Split Casting Pumps With 4 Poleinduction Motor As Per Is 12615: 2011 Or Amended Up To Date , Ci Casing And Casing Ring, Ss 316 Impeller, Ss 410 Shaft And Shaft Sleeve, Coupling Guard, Common Base Plate, Foundation Bolts, Cement Concrete Foundation Etc. Complete With All Respect As Per The Specification And Scope Of Work And Direction Of Engineer In Charge Of Following Range Of Duty Conditions.Note: Duty Condition Of Required Pump Shall Also Be Mentioned In Boq. 142 25.79 Lps, 70 M Head 143 26.83 Lps, 75 M Head 144 15.14 Lps, 79 M Head 145 Providing, Installation, Testing And Commissioning Of Centrifugal Monoblock Pump Set Conforming To Is 9079 Operating At Sync. Speed 2900 Rpm With Requisite Moc Impeller, Priming Funnel, Cock, Suitable Flanges At Suction And Delivery Side. Pump Shall Have Common Shaft For Pump And Motor. Motor Shall Be Suitable For Working On 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor Shall Be Tefc Type And Pump Set Shall Be Suitable For Working At Various Discharge And Head Requirements As Per Scope Of Work. Pump Shall Be Erected Onc.C. Foundation / Cross Channels / Rsj Frame Block With Suitable Foundation Bolts Grouted In C.C. Foundation Block Etc. Complete In All Respect As Perspecification, Scope Of Work And Direction Of Engineer In Charge Of Following Power Rating, Suitable For Prescribed Duty Conditions Mentioned In Td. 146 19.31 Lps, 41M Head 147 20.62 Lps, 54 M Head 148 9.93 Lps, 78 M Head 149 26.15 Lps, 44 M Head 150 18.46 Lps, 62 M Head 151 9.39 Lps, 73 M Head 152 Supplying, Erecting, Testing & Commissioning Of Electrically Operated Travelling Crane ( Eot ) .Main Girder & End Carriage Fabricated From Rollled Steel Section, Gear Box For All Motion, Electro Magnetic Friction Disc Type Brakes, All Safety Limit Switches, Lt Wheels En 9, Double Flanged 4No, With Sq. Cage Motor Of Adequate Rating ( Kw ) , Duly Painted Mechanical Cleaning And One Coat Of Primer And Two Coat Of Synthetic Paint And As Per The Direction Of The Engineer. 153 Span 7 M 6 Mtr. Lift 154 Providing, Lowering, Aligning, Fixing In Position In Pipe Line, Ci D / F Sluice Valves Of Approved Make Of Following Pressure Rating & Dia Complete, Confirming To Is:14846 ( Amended Up To Date ) And Of Following Specifications: Body, Bonnet, Wedge, Gland, Thrust Plate, Cap & Hand Wheel Of Grey Cast Iron Of Is:210 / Fg200 Stem - Ss 304 , Body Seat Ring, Wedge Facing Ring & Bushes - Ltb2 / Ss , Face To Face Dimensions As Per Is 14846 / 2000 ( Amended Up To Date ) , All Exposed Machined Ferrous Surfaces Shall Be Painted With One Coat Of Aluminium Red Oxide Primer Conforming To Is:5660 And Two Coats Of Black Japan Paint Conforming Totype B Of Is 341Or Paint Conforming To Is9862 Or Is2932 ( Non-Toxicsuitable For Drinking Water ) Applied Inside And Outside, Flanges Drilled As Per Is 1538.Nut-Bolt Confirming To Is:1363 And Is: 1367 / Cs / Galvanised Steel.Insersion Rubber Of Black Epdm 6Mm Thick . Suitable Support Structure As Per Directions Of Eic. Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-Incharge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work.Manually Operated Ci Sluice Valve Of Class Pn-1.0 155 100 Mm Dia 156 600 Mm Dia 157 Providing And Fixing Double Flanged Isi Marked Di Class K-9 Pipes As Per Is:8329-2000 ( Amended Up To Date ) , As Vertical Pipes For Rcc Reservoirs Including Specials Required Such As Duck Foot Bend, Bend, Tee Etc. Providing Clamps At Every 3 Mtr, Jointing Materials Such As Nuts, Bolt, Rubber Packing, Hydraulic Testing Etc. Complete In All Respect Up To And From Valve Chamber As Per Direction Of Eic, Technical Specification And Scope Of Work. 158 100 Mm Dia 159 600 Mm Dia 160 700 Mm Dia 161 Design & Construction Of Clear Water Reservoirs Of Required Capacity At Following Places, Including Its Piping, Fittings, Etc Complete In All Respect As Per The Scope Of Work & Specifications Given In The Tender Document At The Following Places & Sizes . 162 Tps / Cps Bhaleri 163 Design, Manufacturing And Supply Of Batch Type Electro Chlorinator Of Capacity As Per Requirement Of Site 164 Part : C Repair Works 165 Repair Of Valves From Karamsana To Bhaleri 166 Providing, Lowering, Aligning, Fixing In Position And Jointing In Pipe Line, Di Body Flanged End Tamper Proofkinetic Air Valve Of Approved Makes Of Following Pressure Rating And Dia And As Per Following Specifications: Governing Standard - Awwa C512 / Is:14845:2000 ( Amended Up To Date ) Body, High Pressure Cover , Low Pressure Cover, Cowl Andjoint Support Ring - Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865, Float- Lp Ball & Hp Ball : Aisi 304 Stainless Steel, Seat Ring & Gasket - Epdm / Nbr , Hp Orifice & Hp Orifice Plug : Bronze / Ss , Bush: Bronze , Flanges As Per Is / Bs, Drilled As Per Is:1538. Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bonded Epoxy ( Non-Toxic & Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Micron Applied On Body & Coverinside And Outside .Fasteners - Cs / Galvanised Steel, Outlet Of Big Orifice Will Have A Screen To Prevent Tamper Of Float, With Di Metal Seated D / F Non Rising Stem. Sluice Valves As Per ( Is: 14846 Amendedupto Date ) Pn 1.6 Ratings. Valves Including All Material, Labour, Testing And Commissioning As Per Technical Specifications And As Per Direction Of Engineer In Charge. Note: Rates Are Exclusive Of Connecting Tee, Pipe Piece And Earth Work. ( Class Pn 1.6 ) 167 150 Mm Dia 168 200 Mm Dia 169 Providing, Lowering, Aligning, Fixing In Position In Pipe Line At Work Site, Di D / F Resilient Seated ( Soft Seated ) Sluice Valves ( Gate Valves ) , Vacuum Tight ( Bubble Tight ) , Straight And Pocket Less Body Passage Of Approved Make Of Following Class & Dia Complete Confirming To Bs-En-1171 / Awwa C-509 And Of Following Specifications: Body & Bonnet Of Ductile Cast Iron Of Grade Ggg40 / Ggg50 As Per Din 1693 Or Gr Sg-400 / 12 As Per Is 1865 Or Equivalent Grade As Per Is :3896-Part2-1985 And Subsequent Revisions, Wedge Of Same Material As Body & Shall Vulcanisedrubber Lined With Epdm ( Food Grade Quality ) And Seals Of Nbr Face To Face Dimensions As Per Bs 5163-89 / Is 14846 / 2000 ( Amended Up To Date ) / Din 3202 F4, Stem / Spindle Of Ss ( Aisi 316 Or Equivalent ) Electrostatic Epoxy Powder ( Ep-P ) / Fusion Bond Epoxy ( Non-Toxic- Suitable For Drinking Water ) Coated With Minimum Thickness Of 250 Microns Inside And Outside, Drilled As Per Is 1538. Nut-Bolt Confirming To Is:1363 And Is: 1367 ( Galvanised Steel ) Insersion Rubber Of Black Epdm 6Mm Thick. Suitablesupport Structure As Per Directions Of Eic, Sluice Valves Including All Jointing & Jointing Material, Labour, Testing And Commissioning Along With Pipe Line As Per Technical Specifications And As Per Direction Of Engineer-In-Charge. Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 170 Manually Operated Resilient Seated Sluice Valves Of Class Pn 1.0 / 1.6Sectional Valves 171 150 Mm Dia 172 200 Mm Dia 173 900 Mm Dia With Gear 174 Providing, Lowering, Aligning, Fixing In Position And Jointing Ms Dismantling Joint Fabricated Steel ( Suitable For Sluice Valves Etc. ) As Per Is Specificationscompleteofthefollowingsizesincludingall Jointing Material, Costofalllabour, Testingandcommissioningand As Per Technical Specifications And Direction Of Engineer In-Charge. Class Pn 1.0 / 1.6 175 900 Mm Dia 176 Construction Of Valve Chamber As Per Approved Drawing And Specification Of Engineer In Charge 177 Type G Size Up To 800Mm To 900 Mm 178 Major Repair Of Pmc Office Building, Residential Buildings At Pmc Campus, All Work Civil, Electric, Water Supply, Road, Drainage Cleaning, Horticulture, Etc. Complete 179 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 180 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 181 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 182 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 183 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 184 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 185 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 186 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 187 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 188 Scraping Old Surface And Redoing Lime Loi Or Sandla. 189 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 190 5.5 Mm Thick Plain Glass Panes. 191 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 192 5.5 Mm Thick Plain Glass Panes. 193 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 194 In Existing Roof. 195 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 196 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 197 Depth 50 Mm To 75 Mm. 198 Depth 75 Mm To 100 Mm. 199 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 200 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 201 4Wide 202 6 Wide 203 Panel By 204 Shuttering Ply - 9Mm Thick ( Commercial ) 205 Wire Gauge 14 Mesh X 24 Gauge 206 Plain Glass Panes 4Mm Thick 207 Aldrop Of Mild Steel 208 12 Long X12mm Dia 209 8 Long X 10Mm Dia 210 Stopper Of Aluminium With 211 Single Rubber Gutka 212 Double Rubber Gutka 213 Door Springs Of Mild Steel 214 Steel Hinges 215 For Wooden Chowkhat 3 Size. 216 For Wooden Chowkhat 4 Size 217 For Stone Chowkhat , 4Size 218 Mild Steel Tower Bolt 6 Long 219 Steel Locking Bolt 220 Steel Handle 6 Size 221 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 222 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 223 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 224 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 225 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 226 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 227 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 228 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 229 Hot Rolled Deformed Bars ( Is : 1139 ) . 230 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 231 20 Mm Thick. 232 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 233 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 234 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 235 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 236 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 237 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 238 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 239 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 240 Sand Or Other Approved Stone 25 Mm Thick. 241 Sand Or Other Approved Stone 35 Mm Thick. 242 Sand Or Other Approved Stone 50 Mm Thick. 243 Kota Stone 25 To 30 Mm Thick. 244 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 245 Jhunjhunu / Jalore ( Red / Choclate Colour ) 246 Above 3601 Cm2 Slabs 247 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 248 Size Of Tile 60X60 Cm 249 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 250 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 251 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 252 Size 100X75mm. 253 Size 125X100mm. 254 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 255 Size 125 X 100Mm. 256 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 257 30 Mm Thick Shutter 258 Commercial Veneer Both Side 259 Decorative Teakveneer One Side 260 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 261 30 Mm Thick Ghana Teak Wood Grade - I 262 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 263 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 264 1:3:6 Or Richer Mix. 265 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 266 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 267 In Cement Mortar. 268 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 269 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 270 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 271 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 272 Ms Sheet 18 Swg 273 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 274 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 275 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 276 14 Mesh X 24 Gauge 277 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 278 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 279 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 280 Providing & Fixing 12 Mm Thick Tegular Edge Glass Fibre Reinforced Gypsum False Ceiling Tiles Of Size 595 X 595 Mm In True Horizontal Level Suspended On Inter Locking Metal Grid Of Hot Dipped Galvanised Steel Sections ( Galvanized @ 170 Gsm / Sqm. ) Consisting Of Main “T” Runner With Suitably Spaced Joints To Get Required Length And Of Size 24X38mm Made From 0.30Mm Thick ( Minimum ) Sheet Spaced At 1200Mm Center To Center And Cross “T” Of Size 24X25mm Made Of 0.30Mm Thick ( Minimum ) Sheet, 1200Mm Long Spaced Between Main “T” At 600Mm Center To Center To Form A Grid Of 1200X600 Mm And Secondary Cross “T” Of Length 600Mm And Size 24X25mm Made Of 0.30 Mm Thick ( Minimum ) Sheet To Be Interlocked At Middle Of The 1200X600mm Panel To Form Grids Of 600X600mm And Wall Angle Of Size 21X21x0.30 Mm And Laying False Ceiling Tiles Of Approved Texture In The Grid Including, Wherever, Required, Cutting / Making, Opening For Services Like Diffusers, Grills, Light Fittings, Fixtures, Smoke Detectors Etc. Main “T” Runners To Be Suspended From Ceiling Using Gi Slotted Cleats Fixed To Ceiling With 6 Mm Dia And 50Mm Long Dash Fasteners, 4Mm Gi Adjustable Rods With Galvanised Level Clips Spaced At 1200Mm Center To Center Along Main T, Bottom Exposed Width Of 24Mm Of All T-Sections Shall Be Pre-Painted With Polyester Paint, All Complete At All Heights As Per Specifications Drawings And As Directed By Engineer-In-Charge. 281 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 282 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 283 Old Work ( One Or More Coats ) . 284 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 285 Two Or More Coats On New Work. 286 One Or More Coats On Old Work. 287 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 288 For Area Of Each Slab Up To 900 Sq. Cm 289 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 290 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 291 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 292 Add 10 % For Water Supply And Sainatry Works 293 Add 10 % For Electric Works 294 Horticulture 295 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 296 Girth From 300 Mm To 600 Mm 297 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 298 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 299 From Yard Manure ( Organic ) 300 Compost 301 Goat Dungmanure 302 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 303 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 304 Methly Prathion 2% 305 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 306 Different Flowing Plants 900 Mm To 1500 Mm 307 Different Varrities Of Shrubs 600 Mm To 900 Mm 308 Different Varrities Of Climbers 900 Mm To 1500 Mm 309 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 310 In Rows 7.5 Cms. Apart In Either Direction 311 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 312 Road And Drainage Work 313 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 314 Grading - Ii Material 315 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 316 Crusher Broken -Grade-Ii ( 63-45Mm ) 317 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 318 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 319 With Bitumen Vg-Grade 30 320 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 321 With Bitumen Vg-Grade 30 322 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 323 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 324 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 325 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 326 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 327 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 328 200 Mm Internal Diameter 329 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 330 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 331 Providing And Laying Lean Cement Concrete 1:4:8 In Sub- Base Over A Prepared Sub-Grade With Coarse And Fine Aggregate Conforming To Is: 383, The Size Of Coarse Aggregate Not Exceeding 25 Mm, Aggregate Cement Ratio Not To Exceed 15:1, Aggregate Gradation After Blending To Be As Per Table 600-1, Cement Content Not To Be Less Than 150 Kg / Cum, Optimum Moisture Content To Be Determined During Trial Length Construction, Concrete Strength Not To Be Less Than 10 Mpa At 7 Days, Mixed In A Batching Plant, Transported To Site, Laid With A Paver With Electronic Sensor, Compacting With 8-10 Tonnes Vibratory Roller, Finishing And Curing Complete As Per Clause 601, 112 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion 332 Providing And Laying Un-Reinforced, Plain Cement Concrete Mix With Concrete Mixer & Vibrator Pavement Over A Prepared Sub Base With 43 Grade Cement , Coarse And Fine Aggregate Conforming To Is: 383, Maximum Size Of Coarse Aggregate Not Exceeding 25 Mm, Mixed As Per Approved Mix Design, Laid, Spread, Compacted And Finished In A Continuous Operation Including Provision Of Contraction, Expansion, Construction And Longitudinal Joints Etc Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 333 Pcc M-30 334 Campus Lighting 335 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 336 7 Mtr 337 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 338 Single Arm Overhang 339 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 340 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 341 10.0 Sq.Mm2 Cor 342 Add 5% Over Head 343 Repair Of Pump House Building At Churu, Bhaleri Like Repair Of Plaster, Floor, Roof, Doors, Windows, Colour Washing, Painting Etc. 344 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 345 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 346 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 347 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 348 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 349 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 350 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 351 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 352 Scraping Old Surface And Redoing Lime Loi Or Sandla. 353 Patch Repair To Cement Concrete Floor Including Digging Out Old Floor In Regular Shape And Removal Of Rubbish Curing Etc. Complete In All Respects. 354 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 355 5.5 Mm Thick Plain Glass Panes. 356 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 357 In Existing Roof. 358 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 359 Depth 50 Mm To 75 Mm. 360 Depth 75 Mm To 100 Mm. 361 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 362 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 363 4Wide 364 6 Wide 365 Panel By 366 Shuttering Ply - 9Mm Thick ( Commercial ) 367 Wire Gauge 14 Mesh X 24 Gauge 368 Plain Glass Panes 4Mm Thick 369 Aldrop Of Mild Steel 370 12 Long X12mm Dia 371 8 Long X 10Mm Dia 372 Stopper Of Aluminium With 373 Single Rubber Gutka 374 Double Rubber Gutka 375 Door Springs Of Mild Steel 376 Steel Hinges 377 For Wooden Chowkhat 3 Size. 378 For Wooden Chowkhat 4 Size 379 For Stone Chowkhat , 4Size 380 Mild Steel Tower Bolt 6 Long 381 Steel Locking Bolt 382 Steel Handle 6 Size 383 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 384 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 385 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 386 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 387 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 388 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 389 Suspended Floors, Roofs, Landings, Staircases, Balconies, Girders, Cantilevers, Bands , Coping, Bed Plates, Anchor Blocks, Sills, Chhajjas Lintel, Beam Etc. 390 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 391 Hot Rolled Deformed Bars ( Is : 1139 ) . 392 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 393 20 Mm Thick. 394 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 395 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 396 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 397 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 398 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 399 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 400 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 401 30 Mm Thick Shutter 402 Commercial Veneer Both Side 403 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 404 30 Mm Thick Ghana Teak Wood Grade - I 405 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 406 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 407 1:3:6 Or Richer Mix. 408 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 409 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 410 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 411 Ms Sheet 18 Swg 412 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 413 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 414 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 415 14 Mesh X 24 Gauge 416 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 417 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 418 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 419 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 420 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 421 Old Work ( One Or More Coats ) . 422 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 423 Two Or More Coats On New Work. 424 One Or More Coats On Old Work. 425 Cement Concrete Flooring 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate ) Finished With A Floating Coat Of Neat Cement Including Cement Slurry, Making Of Lines Or Groove Etc Complete But Excluding The Cost Of Nosing Of Steps Etc. Complete. 426 40 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 427 75 Mm Thick With 20 Mm Thick Nominal Size Aggregate. 428 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 429 For Area Of Each Slab Up To 900 Sq. Cm 430 For Area Of Each Slab Up To 901 To 2000Sq. Cm 25 Mm Thick Slab. 431 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 432 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 433 Add 5 % For Water Supply And Sainatry Works 434 Add 10 % For Electric Works 435 Horticulture 436 Cutting Of Trees, Including Cutting Of Trunks, Branches And Removal Of Stumps, Roots, Stacking Of Serviceable Material With All Lifts And Up To A Lead Of 1000 Mtrs And Earth Filling In The Depression / Pit To Required Compaction As Per Mort&H Specification Clause 201. ( Measurment Of Girth To Be Done At Height Of 1 M Above Ground Level ) 437 Girth From 300 Mm To 600 Mm 438 Clearing Grass And Removal Of Rubbish ( Maximum 150Mm ) By Manual Means And Disposal At A Lead Of 50 Metres As Per Mort&H Specification Clause 201. 439 Supply Of Dry Manure Including Loading Unloading, Transportation & Stacking At Site. 440 From Yard Manure ( Organic ) 441 Compost 442 Goat Dungmanure 443 Supply & Stacking Good Earth At Site Complete Including Loading Unloading & Transporation Etc. 444 Supply Of Insecticides & Pesticides At Store In Dust / Liquid Form Complete 445 Methly Prathion 2% 446 Supply Of Different Varities Of Tree / Shrubs / Climbers According To Height And Age Of The Plant At Site Including Loading / Unloading & Transportation Etc. Complete: 447 Different Flowing Plants 900 Mm To 1500 Mm 448 Different Varrities Of Shrubs 600 Mm To 900 Mm 449 Different Varrities Of Climbers 900 Mm To 1500 Mm 450 Laying Of Lawns Including Ploughing Levelling Breaking Of Clods Manuring & Removal Of Stones Etc. ( Cost Of Manure Of Extra Good Earth To Be Paid Seperatley ) Maintenance Of Lawns For 30 Days Of More Till The Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing In The Duration Of Planting If Lawn Die Some Where The Contractor Will Replant It At His Own Cost. 451 In Rows 7.5 Cms. Apart In Either Direction 452 Renovating Lawns Including Weeding Cheeling The Grass Forking The Ground Top Dressing With Manure. Mixing The Same With Forked Soil Watering Maintaing The Lawns For 30 Days Or More Till Grass Forms A Thick Lawns Free From Weeds & Fit For Mowing & Disposal Of Rubbish As Directed. 453 Road And Drainage Work 454 Providing, Laying, Spreading And Compacting Of Granular Sub-Base By Providing Close Graded Material ( Table 400-1 ) , Spreading In Uniform Layers With Motor Grader On Prepared Surface, Mixing By Mix In Place Method With Rotavator At Omc, And Compacting With Vibratory Roller To Achieve The Desired Density, Complete As Per Mort&H Specification Clause - 401 Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 455 Grading - Ii Material 456 Providing Laying, Spreading And Compacting Stone Aggregates Of Specific Sizes As Per Table 400-7 To Water Bound Macadam Specification Including Spreading In Uniform Thickness; Hand Packing, Rolling With Power Roller 8-10 Tonnes, In Stages To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening ( Table 400-8 ) Binding Materials To Fill Up The Interstices Of Coarse Aggregates, Watering ( With Water Browser ) And Compacting To Required Density, Making Necessary Earthen Bund To Protect Edges As Per Clause 404 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion Complete 457 Crusher Broken -Grade-Ii ( 63-45Mm ) 458 Providing And Applying Primer Coat Over Prepared Surface Of Granular Base With Bitumen Emulsion As Per Is : 8887 And Approved Quality @ 0.6 Kg / Sqm With The Help Of Spray Set Fitted On Bitumen Container ( Boiler ) After Cleaning The Surface Including Removing Of Binding Material And Other Foreign Matter With Wire Brushes And Small Picks, Sweeping With Brooms Or Soft Brushes And Finally Dusting With Old Gunny Bags And Compressed Air To Receive Bituminous Treatment Complete As Per Clause 502 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 459 Providing And Laying Open Graded Premix Carpet 20Mm Thick ( Compacted ) , On Prepared Surface In A Single Course As Wearing Course, Composed Of Specified Graded Crushed Stone Aggregate As Per Table 500-23, Premixed With Bituminous Binder @ 14.60 Kg / 10Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) , Including Loading Of Material With F.E. Loader, Hot Mixing Of Stone Aggregate And Bitumen In Computerised Hot Mix Plant, Transporting The Mixed Material By Tippers To Paver And Laying With Paver Finisher Fitted With Electronic Sensor Control To The Required Level And Grade, Compacting Smooth Wheeled Roller 8-10 Tonne Capacity And Finishing To Required Level To Achieve The Desired Density As Per Clause 511 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion But Excluding Cost Of Tack Coat / Seal Coat. 460 With Bitumen Vg-Grade 30 461 Providing And Applying Premixed Seal Coat Type B Comprising Of Thin Application Of Fine Aggregate 0.06 Cum / 10 Sqm Premix With Bitumen Binder @ 6.8 Kg / 10 Sqm ( Including Cost Of Anti-Stripping Compound Wherever Required ) Laying With Paver Finisher With Electronic Sensor Control And Rolling With Power Roller 8-10 Tonne Complete As Per Clause 513 Of Mort&H Specification Including All Material, Labour, Machinery, Lighting, Guarding And Maintenance Of Diversion. 462 With Bitumen Vg-Grade 30 463 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 464 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 465 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 466 Brick Work With F.P.S. Bricks Of Class Designation 75 Infoundation And Plinth In: 467 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 468 Providing And Laying Reinforced Cement Concrete Pipe Np4 / Prestrssed Concrete Pipe For Culverts Including Jointing Ends And Fixing Collar With Cement Mortar 1:2 Complete As Per Clause 1000 & 2900 Of Mort&H Specification Including All Material, Labour Form Work, Machinery. 469 200 Mm Internal Diameter 470 Providing And Fixing Of Reinforced Ferro-Cement Drain Covers Designed For A Class Loading Duly Marked On Cover With Adequate Steel Reinforcement Having Thickness 75Mm To 150Mm Anti Corrosive Bitumen Painted M.S. Plate , Rim And M.S. Lifting Hooks, Admixtures Like Plasticizer, Bond Improving Compound, Shrinkage, Resistance Compound, Abrasion Resistant Complete As Per Approved Design Etc 471 Standard Size 600X800mm ( 75Mm Thick ) For Span 300 To 450Mm 472 Campus Lighting 473 Supply And Erection Of Octagonal Pole Of Following Length And Dimension As Per Table-3 With Base Plate On The Cement Concrete Foundation Of M-15 / M-20 Grade ( 1:1.5:3 ) With The Help Of Anchor Bolts Of Grade 6.8 ( Is 1367 P Iii ) . The Pole Shall Be Made Of S-355Jo Grade Steel Sheet , Folded Lengthwise To Obtained Octagonal Shape, Having Single Longitudinal Seam Weld And Hot Dipped Galvanised Internally & Externally In Accordance With Is 2629. The Pole Shall Have A Weatherproof Flush Door And Locking Arrangements. The Complete Work Shall Be Supervised And Certified By The Manufacturers For Satisfactory Supply, Erection, Testing And Commissioning. 474 7 Mtr 475 Supply, Erection And Fixing Of Hot Dipped Galvanised Overhang ( 60 X 3.25 Mm ) With Cap ( 250 X 137.9 X 4.05 Mm ) Over The Existing Poles 476 Single Arm Overhang 477 P & F Of Ip 65 / 67 Protected Led Flood Light System With Aluminium Housing, 3 X 1W, 220V, 50Hz Led Lamps With Dynamic Color Changing Capability Available In Quick Connecting Cable Coupled With Various Mounting Accessories. Ability To Create 16.7 Million Uniform, Smooth And Brilliant Colors Without Revealing Any Lamp Image. Available In 5 Colors – Amber, Green, Blue, Red And White. 478 Providing & Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Makein Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Underlayer Ofsand, Second Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size 479 10.0 Sq.Mm2 Cor 480 Repair Of Residantialbuilding At Churu, Bhaleri, Like Repair Of Plaster, Floor, Roof, Doors, Windows, Color Washing, Painting Etc. 481 Repair To Brick Masonary In Cement Sand Mortar With Taking Out Of Deceayed From Wall And Replaceing With New Briks.Cement Sand Mortar 1:6. With New Brick. 482 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 483 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 484 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 485 Scraping Old Surface And Redoing Lime Loi Or Sandla. 486 Renewing Glass Panes, With Puty And Nails Wherever Necessary: 487 5.5 Mm Thick Plain Glass Panes. 488 Renewing Glass Panes With Wooden Fillets Wherever Necessary: 489 5.5 Mm Thick Plain Glass Panes. 490 Providing And Fixing 16 Mm M.S. Fan Clamps Of Standard Shape And Size In R.C.C. Slab / Stone Slab Roofing Including Cutting Chase And Making Good And Painting Exposed Portion Of The Clamps Complete: 491 In Existing Roof. 492 Guniting Damaged R.C.C. Slab, Beams And Columns For Strengthening With Cement Sand Mortar 1:2 ( 1-Cement:2-Sand ) Including Preparing The Surface, Making V Shaped Joints, Cleaning The Reinforcement Bars With Jet Of Potable Water And Drying With Compressed Air, Including Cost Of Centering And Shuttering And Finishing To Match The Existing Surface Etc. Complete, Including Provided M.S. Welded Mesh To Gauge 25 Mm X 25 Mm Framing With Average Thickness Of 25 Mm. 493 Chopping Loose And Cracked Concrete To Required Depth, Cleaning The Exposed Surface Of Steel And Concrete With Wire Brush And Sand Blasting, Clening With A Jet Of Water / Air As Necessary And Getting It Dried With Compressed Air Including All Scaffolding: 494 Depth 50 Mm To 75 Mm. 495 Depth 75 Mm To 100 Mm. 496 Repairofdoor, Windowshuttersincludingcostofmaterialandlabourforchangeofdamaged : 497 Style / Rail Of Teak Wood 30Mm Thick / Aluminium Section 498 4Wide 499 6 Wide 500 Panel By 501 Shuttering Ply - 9Mm Thick ( Commercial ) 502 Wire Gauge 14 Mesh X 24 Gauge 503 Plain Glass Panes 4Mm Thick 504 Aldrop Of Mild Steel 505 12 Long X12mm Dia 506 8 Long X 10Mm Dia 507 Stopper Of Aluminium With 508 Single Rubber Gutka 509 Double Rubber Gutka 510 Door Springs Of Mild Steel 511 Steel Hinges 512 For Wooden Chowkhat 3 Size. 513 For Wooden Chowkhat 4 Size 514 For Stone Chowkhat , 4Size 515 Mild Steel Tower Bolt 6 Long 516 Steel Locking Bolt 517 Steel Handle 6 Size 518 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 519 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 520 M10 Grade Nominal Mix 1: 3: 6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stoneaggregate 20Mm Nominal Size ) . 521 Making Plinth Protection 50Mm Thick Of Cement Concrete 1:3:6 ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggre -Gate 20 Mm Nominal Size ) Over 75Mm Bed Of Dry Brick Ballast 40Mm Nominal Size Well Rammed And Consolidated And Grouted With Fine Sand Including Finishing The Top Smooth. 522 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 523 20 Mm Thick. 524 Providing And Fixing Expanded Metal Mesh Of Size 20X60 Mm And Strands 3.5 Mm Vide 1.6 Mm Thick Weighing 3.64 Kg. Per Sqm. For Encasing Ofrolledsteel Sections In Beams, Columns And Grillages Excluding Cost Of Hangers. 525 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 526 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 527 Half Brick Masonry In Superstructure , Above Plinth Level Upto Floor Fivelevelusing F.P.S. Bricks Of Designation 75 528 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 529 Brick Work In Partition In Super Structure Upto Five Storey 7Cm. Thick ( Brick On Edges ) Using F.P.S. Bricksof Class Designation 75 In : 530 Cement Mortar 1:4 ( 1-Cement:4-Coarse Sand ) . 531 Supplying And Fixing Machine Cut And Polished Stone Shelves, Tands And Sills In Cm 1:3 With Machine Cut Edges: 532 Kota Stone 25 To 30 Mm Thick. 533 Providing And Fixing Granite Stone Slab Mirror Polished And Machine Edge Cut In Walls, Pillars, Steps, Shelves, Sills, Counters. Floors Etc. Laid On 12Mm ( Av. ) Thick Base Of Cement Mortar 1:3 Jointing With White Cement Mortar 1:2 ( 1 White Cement: 2 Marble Dust ) With Pigment To Match The Shade Of The Marble Slab Complete Including Grinding, Rubbing And Polishing Of: 534 Jhunjhunu / Jalore ( Red / Choclate Colour ) 535 Above 3601 Cm2 Slabs 536 Providing And Laying Vitrified Floor Tiles In Different Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption’S Less Than 0.08% And Conforming To Is : 15622 Of Approved Make In All Colours And Shades, Laid On 20Mm Thick Cement Mortar 1:4 ( 1 Cement: 4 Coarse Sand ) Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete. 537 Size Of Tile 60X60 Cm 538 Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is : 15622 ( Thickness To Be Specified By The Manufacture ) Of Approved Make In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineer In Charge In Skiriting, Risers Of Steps And Dados Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3 Kg Per Sqm Including Pointing In White Mixed With Pigment Of Matching Shade Complete. 539 Category - I : Kajariya, Jhonson, Orient, Somani Make Etc. 540 Providing & Fixing In Cement Sand Mortar 1:4 Single Paitam ( Rebated ) Stone Doors Windows And Ventilator Frames Of Approved Quarry : 541 Size 100X75mm. 542 Size 125X100mm. 543 Providing And Fixing In Cm 1:4 Double Paitam ( Rebated ) Stone Door Window And Ventilator Frames Of Approved Quarry : 544 Size 125 X 100Mm. 545 Providing And Fixing External Grade Board Solid Core Single Leaf Flush Door Shutters Isi 2202-67 Marked Using Phenol Formal, Dehydreresin In Glue Both Sides With Approved Steel Fittings Complete As Per Annexure ‘A’ 546 30 Mm Thick Shutter 547 Commercial Veneer Both Side 548 Decorative Teakveneer One Side 549 Providing And Fixing Fully Paneled Double Leaf Shutter For Doors As Per Approved Design And Drawing With Approved Ordinary C.P. / Oxidized Steel Fittings As Per Annexure – A’ And Width Of Styles & Top Rails Of 100Mm And Lock Rails Width Of 150Mm And Bottom Rails Of 200Mm Width Including Teak Wood Beading Of Size 19Mmx12mm On Both Faces Complete : 550 30 Mm Thick Ghana Teak Wood Grade - I 551 Wire Gauge 24 Gauge 14 Mesh Of Is Designation 85 Gauge Wires Of Dia 0.56 Mm Panels 552 Demolishing Cement Concrete Including Disposal Of Material Within 50 Meter Lead : 553 1:3:6 Or Richer Mix. 554 Demolishing Of R.C.C. Work Including Stacking Of Steel Bars And Disposal Of Unserviceab Le Material Within 50 Meters Lead. 555 Demolishingbrickwork Including Stacking Of Serviceable Material And Disposal Of Unserviceable Material Within 50 Meters Lead. 556 In Cement Mortar. 557 Providing And Fixing T-Iron Frames For Doors, Windows And Ventilators Of Mild Steel Tee-Sections, Joints Mitred And Welded With 15X3 Mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required Including Fixing Of Necessary Butt Hinges And Screws And Applying A Priming Coat Of Approved Steel Primer. 558 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 559 Providing & Fixing Ms Sheet Single Leaf Door Shutters In Angle Iron Frame 35X35x5 Mm Suitablly Diagonally Braced With 25X3mm Flat Ironabove And Below Lock Rail Of Size 50X5 Mm Beading Extra Includingall Fittings, As Per Direction Of Engg. Incharge But Excluding Coes Of Chokhats Including Two Coats Of Anti Corrastie Red Oxide Primer Panit. 560 Ms Sheet 18 Swg 561 Providing & Fixing Steel Glazed Doors, Windows And Ventilators With Shutters Of Standred Rolled Steel Section Joint Mitred And Welded With Steel 13X3mm Lugs 10 Cm. Long Embedded In Cement Concrete Blocks 15X10x10 Cm. Of 1:2:4 ( 1-Cement:2-Coarse Sand:4-Graded Stone Aggregate 20 Mm Nominal Size ) Or With Wooden Plugs And Screws Or Rawl Plugs And Screws Or With Fixing Clips Or With Bolts And Nuts As Required, Including Providing And Fixing Of Plain Glass Panes 4Mm Thick With Copper Glazing Clips And Special Metal-Sash Putty Of Approved Make, Or Metal Beading With Screws Complete Including Priming Coat Of Approved Steel Primer, Excluding The Cost Of Metal Beading And Other Fittings Except Necessary Hinges Of Pivots Steel Handles And Peg Stay Etc. As Required. 562 Patially Fixed And Partially Openable Fixed Area Not Exceed 33% 563 Supplying And Fixing Fixed Wire Gauge To The Metal Frame Of Rolled Section By Metal Beading 20X3mm With Suitable Screw At Not Exceeding 150 Mm Distance. 564 14 Mesh X 24 Gauge 565 Providing And Fixing 20 Mm Thick Precast Terrazo Tiles Of Approved Make, With Marble Chips Of Size Upto 6Mm Laid Over Roof With Neat Cement Slurry Mixed With Pigment To Match The Shade Of The Tiles, Including Cutting , Grinding Rubbing With Machinecomplete On 20 Mm Thick Bed Of Cement Sand Mortar 1 : 4. 566 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 567 Distempering With Dry Distemper Of Approved Brand And Shade ( Two Or More Coats ) And Of Required Shade On New Work, Over And Including, Priming Coat Of Whiting To Give An Even Shade Including All Scaffolding. 568 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 569 New Work ( Two Or More Coats Applied @ 3.84 Kg / 10 Sqm ) . 570 Old Work ( One Or More Coats ) . 571 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 572 Two Or More Coats On New Work. 573 One Or More Coats On Old Work. 574 Kota Stone Slab Flooring 25 Mm Thick Over 20 Mm ( Average ) Thickbase Laid Over And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Completewith Base Of Cement Mortar 1 : 4 ( 1 Cement : 4 Coarse Sand ) 575 For Area Of Each Slab Up To 900 Sq. Cm 576 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 577 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 578 Add 10 % For Water Supply And Sainatry Works 579 Add 10 % For Electric Works 580 Repair Of Boundry Wall At Pmc, Bhaleri, Including Provinf Fixing Of Borbed Wire Fancing Repair Of Gates Et. 581 Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Taking Out The Excavated Soil And Depositing And Refilling Of Jhiri With Watering & Ramming And Disposal Of Surplus Excavated Soil As Directed With In A Lead Of 50 Meter.All Kinds Of Soils 582 Random Rubble Stone Masonary For Foundation And Plinth In Cement Sand Mortar Above 30 Cm. Thick Wall In : 583 Cement Mortar 1:6 ( 1-Cement:6-Sand ) . 584 Repairs To Plaster Of Thickness 12Mm To 20Mm In Patches Of Area 2.5 Sq. Metres And Under Including Cutting The Patch In Proper Shape, Raking Out Joints And Preparing And Plastering The Surface Of The Walls Complete Including Disposal Of Rubbish To The Dumping Ground Within 50 M Lead : With Cement Mortar 1 :4 ( 1 Cement : 4 Fine Sand ) 585 Repair To Stone Masonary In Cement Sand Mortar 1:6 With Old And New Stone. 586 Cutting Jhiri Above 75Mmx75mm And Below 150X150 Mm Etc. And Making Good. 587 Providing And Laying In Position Cement Concrete Including Curing Compaction Etc. Of Specified Grade Excluding The Cost Of Centering And Shuttering =All Up To Plinth Level 588 M15 Grade Nominal Mix 1: 2: 4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stoneaggregate 20Mm Nominal Size ) . 589 Providing And Laying In Position Specified Grade Ofcement Concrete For Rcc Structural Elements Upto Floor Five Level Including Curing, Compaction, Finishing With Rendering In Cement Sand Mortar 1:3 ( 1 Cement: 3 Coarse Sand ) And Making Good The Joints And Cost Of Plastizers ( If Required ) Excluding The Cost Of Centering, Shuttering And Reinforcementfor Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Etc. M20 Grade Nominal Mix / Design Mix 590 Centering & Shuttering With Plywood Or Steel Sheets Including Strutting, Propping Bracing Both Ways With Steel Propsand Removal Of Formwork For Upto Floor Five Level For : 591 Columns, Pillars, Posts And Struts Etc. 592 Providing And Fabricating Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding ( Including Cost Of Binding Wire ) All Complete Up To Floor Five Level. 593 Hot Rolled Deformed Bars ( Is : 1139 ) . 594 Plaster On New Surface On Walls In Cement Sand Mortar 1:6 Including Racking Of Joint Etc. Complete Fine Finished: 595 20 Mm Thick. 596 Brick Work With F.P.S. Bricks Of Class Designation 75 In Superstructure Above Plinth Level Upto Floor V Level In All Shapes And Sizes In : 597 Cement Mortar 1:6 ( 1-Cement:6-Coarse Sand ) . 598 Structural Steel Work In Single Section Fixed With Or Without Connecting Plate Including Cutting, Hoisting ( Height Upto 10 M ) , Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. 599 Providing And Fixing Steel Gate Grating And Grills Made Of Angles, Tees, Square Bars Or Other Flats Black Pipe With Holdfast And Fittings Complete As Per Design And Drawing Including Cutting Welding And Fabrication With Priming Coat Of Red Oxide. 600 Removing White Or Colour Wash By Scrapping And Sand Papering And Preparing The Surface Smooth Including Necessary Repairs To Scratches By Sandal / Loi. ( Only For Colour Changing Only ) . 601 Finishing Wall With Water Proofing Cement Paint Of Approved Brand And Manufacture And Or Required Shade To Give An Even Shade Including All Scaffolding: 602 Old Work ( One Or More Coats ) . 603 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Togive An Even Shade : 604 Two Or More Coats On New Work. 605 One Or More Coats On Old Work. 606 Part : E Electrical Works 607 33 Kvring Main Unit Consisting Of 2 Lbs At Incoming & 2 VcbSoutgoing As Per Requirements And Specifications. 608 Stranded Compact Circular Aluminium Conductor, Conductor Screened With Extruded Semi Conducting Compound, Xlpe Insulated, Insulation Screened With Copper Tape, Cores Laid Up, Inner Sheath Of Pe Type, Galvanised Steel Flat Strip Armoured And Overall Pvc Sheathed Cable Confirming To Is 7098 / Ii / 85 With Latest Amendments Of 33 Kv ( Ue ) 609 3Cx300 Mm2 610 Providing & Making Heat Shrinkable Type Indoor / Outdoor / Straight Through Terminations / Joint Kit Of Approved Make Suitable For Xlpe Insulated 33 Kv Cable, With Required Components, Prepration Of Cable Ends, Testing Etc. 611 3 Core 240 / 300 / 400 Sq.Mm 612 Outdoor 613 Indoor 614 Sitc Of Floor Mounted Pmcc ( Indoor, Dust Proff Ip-4X Front Operated With 2 Mm Thick Sheet Metal Compartmentalised ) With All Accessible Parts, Head Shrinkable Sleeves, Smc / Dmc Bus Bar Supports, Padlocking Facility On Outgoing Feeders Etc. 615 Lv Capacitor With Apfc Panel 616 Sitc Of Microprocessor Based Intelligent Power Factor Correction Relay Having Sensitivity Up To 50 Milli Amp Secondary Current And Following Way, Self Analysing Auto C / K Setting According To Targeted Power Factor Setting, The Relay Shall Have Minimum Three Digit Display Unit For Display Of Real Power Factor, Targeted Power Factor, Lag / Lead Capacitor Switching Status, Alarm Output For Under Current, Over Current, Insufficient Compensation, Indication Of Switching On Units, Auto / Manual Status, And 6 To 14 Stage - Sensitivity Upto 50 Milli Amp. 617 Sitc Of Self Healing Mpp / Mp Type Shunt Capacitor ( Banks ) Conforming To Is:13340-41 / Iec :831-1&2 In Existing Panel Or Parallel With Load Terminals , The Capacitor Shall Be Fitted With Discharge Resistors, Pressure Sensitive Disconnector ( Psd ) And Shall Have Dissipation Factor Less Than 0.0025 At 50 Hz And Total Wattage Loss Less Than 0.5 Watt Per Kvar. Including Making Connections With Suitable Capacity Conductors / Cables Testing As Required.Heavy Duty Three Phase 440 V , 50 Hz Capacitor ( Bank ) 618 P / Laying Xlpe Insulated / P.V.C. Sheathed Cable Of 1.1 Kv Grade With Aluminium Conductor Armoured Of Is:7098-I / 1554-1 Approved Make In Ground As Per Is:1255 Including Excavation Of 30Cmx75cm Size Trench, 25 Cm Thick Under Layer Of Sand, Iind Class Bricks Covering, Refilling Earth, Compaction Of Earth, Making Necessary Connection, Testing Etc. As Required Of Size. 619 3 / Cx6 Sq Mm 620 3 / Cx10 Sq Mm 621 3 / Cx16 Sq Mm 622 3 / Cx25 Sq Mm 623 3 / Cx240 Sq Mm 624 Supplying And Making One End Termination With Heavy Duty Double Compression Brass Gland Sibg Type, Aluminium Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Armoured Pvc Insulated & Pvc Sheathed / Xlpe Aluminium Conductor Cable Of 1100 Volt Grade As Required Of Size. 625 3 / Cx6 Sq Mm 626 3 / Cx10 Sq Mm 627 3 / Cx16 Sq Mm 628 3 / Cx25 Sq Mm 629 3 / Cx240 Sq Mm 630 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Covering 631 3C X 2.5 Sq.Mm 632 5Cx1.5 Sq Mm 633 14Cx1.5 Sq Mm 634 Supply & Makingone End Termination With Heavy Duty Single Compression Brass Gland Sibg Type, Copper Lugs Duly Crimped With Crimping Tool, Pvc Tape Etc For Following Size Of Arrmoud Pvc Insulated And Pvc Sheated / Xlpe Almunium Cunductor Cable Of 1100 Volt Grad As Required Size. 635 3C X 2.5 Sq.Mm 636 5C X 2.5 Sq.Mm 637 14 C X 2.5 Sq.Mm 638 Supply, Fabricating & Installing Following Sizes Of Perforated Cable Trays Including Horizontal And Vertical Bends, Reducers Tees, Cross Members And Other Accessories As Required And Duly Suspended From The Ceiling With Suspenders And Including Painting As Required. 639 600Mm X 50Mm X 2.0Mm 640 150Mm X 50Mm X 1.6Mm 641 Supply, Installation, Testing And Commissioning Of Copper Wound Transformers 33 / 0.433 Kv, Three Phase, 50 Hz, Dyn 11, Onan Type , Standard Accessories With Off Load Tap Changer ( +5% To -10% In Steps Of 2.5% ) , Winding / Top --- Temperature Rise Of 45°C / 40°Cfirst Fill Oil, Having Permissible Total Loss Values Not Exceeding 7.5% Of The Maximum Total Loss Values For 11 Kv As Per Energy Efficiency Level - 2 At Basic Insulation Level Conferming To Iss 2026 ( Part- I To Part - Ii ) , Latest Ammended And Is 1180 Part-I : 2014. Transformers Described As Above And As Per The Following Continuous Rating 642 400 Kva 643 1250 Kva 644 1600 Kva 645 S.I.T.C. Of Bus Duct Arrangement In Convenient Sections Complete With Enclouser Of Crca Sheet Steel Of Minimum 2 Mm Thickness, Aluminium Bus Bar And Earth Bus For Use On 3 Phase, 4 Wire, 415 Volts, A.C. Supply With Degree Of Protection Ip-42 For The Following Current Carrying Capacity, Including Jointing Of Sections, Copper Flexible Joints. Expansion Joints, Bends, And Earthing With 2 Runs Of Alum. Strips Etc. As Required 646 1 Straight Run With 2 Earth Bus 3200 Amp 647 Bend 3200 Amp 648 Copper Flexible Tpn 3200 Amp 649 Supply Installation Testing & Commissioning Of Local Push Button Stations 650 Maintenance Free Gel Earthing With Pipe In Pipe / Strip In Pipe Technology Filled With Anti Corrosive Conductive Compound ( Cpri Tested ) Below The Ground In 150 -200 Mm Dia Earth Pit And Surrounding Filled With Required Mineral Filling Compound ( Mfc Should Have Hygroscopic Proper Ty To Retain The Moisture For Long Time To Create Low Resistance Zone ) And C.C. Finished Chamber Covered With Hinge Type With Locking Arrangement C.I Cover. C.I. Frame Of Size 300Mm X300mm Complete Testing Of Earth Resistance As Required Of Following Sizes With Pipe In Pipe Technology ( Inner Pipe Dia / Outer Pipe Dia ) 80 -100 Micron G.I. Coating Of The Size G.I. Pipe 3000 Mm Long , 80 / 40 Mm , Terminal 14 Mm G.I. Strip 651 S & Laying Following Size Earth Wire / Strip In Horizontal Or Vertical Run In Ground / Surface / Recess Including Riveting, Soldering, Saddles, Making Connection Etc. As Required. 652 50Mm X 6Mm G.I. Strip 653 25Mm X 6Mm G.I. Strip 654 25Mm X 3Mm G.I. Strip 655 10 Swg G.I. Wire 656 P & F Lightning Conductor Final Made Out Of 25 Mm Dia., 300 Mm Long Copper Tube Having Single Prong At Top With 85 Mm Dia., 3 Mm Thick Copper Base Plate Including Holes Etc. Complete As Required. 657 Part : F Instrumentation & Scada 658 Sitc Of Ultrasonic Level Transmitter Suitable For Measuring Water Level In Reservoir, Normal Powered 24Vdc, Type Of Transmitter: Two Wire ( 4-20 Ma ) , Cable Entry:1 / 2 Npt ( F ) , Sensor Material: Pp, Slip-On Flange: 2 ½” Flange, Material Of Construction For Slip-On Flange: Pp, Output 4~20Ma, Hart Compatible, Accuracy + / _ 0.2 % As Per Detailed Technical Specification, Scope Of Work And Direction Of Engineer In Charge. Measuring Range 0.0 To 6.0 Mtr 659 Providing, Installation, Testing And Commissioning Of Diaphragm Type Pressure Gauges Dial Size 150 Mm Glycerin Filled Shatterproof Glass, Over Range Protection: 125% Of Maximum Pressure, Material Of Sensor And Other Wetted Parts: Ss Type 316, Housing Material: Die Cast Aluminum 660 Providing, Installation, Testing And Commissioning Of Pressure Transmitter For Water Application: Range: 0-10 Bar / Power Supply: 24 V Dc / Output: 4-20 Ma With Hart / Diaphragm: Ss316l / Process Connection: 1 / 2 Npt ( M ) / Accuracy: 0.15% Protection: Ip671 / 2 M ( Npt ) 661 Sitc Of D / F Full Bore Type Electromagnetic Flow Meter Of Approved Make Of Following Dia And Specifications Complete: Media : Water ( Raw / Chlorinated ) , Pressure : Up To 1.5Mpa, Process Temp: - 50 Deg C, Flow / Meter Tube : Ss 304, Electrode : Ss Aisi 316L / Hastelloy C276 / Tantalum, Lining Material : Hard Rubber / Neoprene / Poly-Urethane ( Pu ) , Flange : Ss / Cs, Flange Standard & Rating : Ansi 150, Coil Housing : Ss Aisi 304 / Carbon Steel / Die Cast Aluminium, With Anticorrosive Paint & Provide Completely Sealed ( Leak Proof ) Construction As Per Requirement Of Iec 60529, Accuracy : ± 0.5 % M.V.- Velocity 0.3 To 10 M / S, Transmitter / Signal Convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V Ac - 50Hz, Output 1 : 4-20 Ma, Output 2: Pulse, Communication Output : Rs 485 / Heart, Display Type : Lcd / Led Display, Cable Entry : M20 X 1.5, Provision Of Ram / Prom To Store Calibration And Configuration Parametersand Totalizer Value During Power Failure, Protection Category- Ip 68 For Sensor ( Flow Tube ) And Ip 67 For Transmitter / Convertor, Including Surge Arrester, If Required, And All Materials Required For Making Connection With Existing Pipeline Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 662 150 Mm Dia 663 200 Mm Dia 664 250 Mm Dia 665 400 Mm Dia 666 900 Mm Dia 667 Sitc Of Bulk Flow Meter With Removable Mechanism Class B Confirming To Iso:4064:2005 / Is: 2373Of Approved Make Of Following Dia Sized Pipelines And Specifications Complete:Media : Water ( Clear ) , Temp. 50 Deg., Pr. Rating: Pn16, Protection Type: Ip- 68, Body Material : Is-210 Gr. Fg-200, Accuracy Class :Class B ( ±2 % @ Nominal Flow Rate ) , Magnetic Drive, Dry Dial, Epoxy Powder Coated, Pulse Out Put Option, Anti-Magnetic Protection Including All Materials And Making Connection With Existing Pipeline Required For Bulk Flow Meter Including Cutting The Existing Pipeline Etc. Complete In All Respect As Per Technical Specification And As Per Direction Of Engineer In-Charge.Note: Rates Are Exclusive Of Tail Piece / Dismantling Joints And Earth Work. 668 Bfm 100 Mm 669 Bfm 150 Mm 670 Bfm 250 Mm 671 Sitc Of Rtu Complete With Di, Do, Ai And Modbus Communication Ports And Power Supply ( 24 V, Dc ) 672 Providing And Laying Stranded / Flexible Annealed Bare Copper Conductor , Xlpe / Pvc Insulated 2 Pair 1.5 Sqmm Suitably Laid Up Together Overall Polyester Taped Al ( Mylar Tape Wrapped ) Along With Atc Drain Wire Overall Pvc Sheathed ( St-1 ) Overall Screened Triad Armoured Instrumentation Cables Generally Confirming To Pas 5308- Part-2-2009 673 Providing & Laying Xlpe / Pvc Pvc Insulated & Pvc Sheathed Armoured Control Cable Of 1.1 Kv Grade With Copper Conductor As Per Is 1275 Including Escavation Of 30Cmx 75 Cm Size Trench 25 Cm Thick Under Layer Of Sand And Lind Class Of Bricks Coveringsize 3C X 2.5 Sq.Mm 674 Supply, Installation, Testing And Commissioning Of Mnre Approved Off Grid Solar Panels For Running Of Motor Pumps With 25 Years Of Linear Generation Warranty, Work Includes Designing Of Solar Panel Area And Ms Frame And Foundation On Ground / Roof Of Pump House Or Cwr, Showing Arrangement Of Panel In Available Space, Installation Of Pv Module On Ms Frame As Per Approved Design And Drawings. Mounting Structure Shall Be Suitably Design To Withstand Wind Velocity Up To 150Km / Hr. The Work Shall Be Executed As Per Detailed Technical Specifications, Approved Drawing And Direction Of Engineer In Charge. Note: There Shallbe5 Year Service Warranty For Solar Panel And Mounting Structure Andsuitable Provision Shall Be Included In Tender Document ( Each Of .5 Kw ) 675 P&F Of Gsm / Gprs Based Data Transmitter Device Forwater Meter Compitable To Scada System. 676 Supply, Installation, Testing, Commissioning Of Plc / Scadasystem Including All Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations. 677 Cps Bhalari 678 Supply, Installation, Testing, Commissioning Of Master Control Room Including All Plc / Scadasystem, Hardwares, Softwares, All Accessorings For Thefollowingpump Houses As Per System Configuration Alongwith Scada For Master Control Centre For Monitering The Water Supply. As Per Scope And Specificationscomplete In All Respect. Ans As Per Direction Of Eic At The Following Locations.Churu 679 Part G : Operation & Maintainance & 680 Cost Of Operation And Maintenance Of The System For 10 Years After Defect Liability Period Of One Year @ 6.0%On Above Items Excluding Villages Inrta Systemand As Per Scope Of Work & Specification 681 Operation And Maintenance Charges 1St Year 682 Operation And Maintenance Charges 2Nd Year 683 Operation And Maintenance Charges 3Rd Year 684 Operation And Maintenance Charges 4Th Year 685 Operation And Maintenance Charges 5Th Year 686 Operation And Maintenance Charges 6Th Year 687 Operation And Maintenance Charges 7Th Year 688 Operation And Maintenance Charges 8Th Year 689 Operation And Maintenance Charges 9Th Year 690 Operation And Maintenance Charges 10 Th Year 691 Part H : Dismantling Of Old Pump Sets 692 Cost For Dismantling Of Old Pump Sets, Electrical Panels And Intrumentation Etc And Depositing In Depatmental Stores As Per Direction Of E.I.C. 693 Tps Karamsana 694 Ir-4 695 Cps / Tps Bhaleri 696 Cps / Tps Churu
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
32.
Housing Urban and Rular Development #10235078 Price Bid
Tender For New Construction Of Cheriyan Nagar Library Chennai; 1 DISMANTALING WORKS 2 Dismantling etc., all complete 3 Brick / Stone Masonry in lime mortar walls 4 Dismantling RCC by manual / by using deploying machineries 5 Doors and Windows including removal of frames, hinges and fastenings 6 CIVIL WORK 7 Earth work excavation for foundation in Hard stiff clay, stiff black cotton, hard red earth, shales murram, gravel,stoney earth and earth mixed with small size bouldersand Sand, silt or other loose soil, wet sand,or silt not under water, light black cotton soil, sandy loam ordinary soil and to full depth as may be directed except in hardrockrequiring blasting inclusive of shoring shuttering and baling out water and cleaning and levelling the site etc.,complete SS.20B 10 cum 8 Carting away surplus excavated earth available with in the campus is to be carted to a lead of within 40 KM from site. The rate shall include loading into the tipper/ lorry transporting and unloading, leveling and the earth scooped by bulldozers grading etc.,complete with all respects complying with relevant standard specification, as directed by the Departmental Officers. Rate to include materials, loading, unloading, transportation, plant and machinery, hire and fuel charges for tools and plants and other incidental charges, royalties, seignorage and taking statutory approvals as necessary to carry out the work as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 9 Supplying and filling in foundation andbasement with Crushed Stone Sand (M- Sand) in layers of not more than 15cm thick well rammed watered and compacted etc., complete complying with standard specification. 10 Supplying and filling in foundation, basement, etc with filling Gravel inwellrammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 12 Providing pre-constructional Antitermite treatment including cost of chemicals labour as per standard specifications for preparing the area for treatment by spraying chemicals and other incidental charges etc.. complete. The rates should be for antitermite treatment from the plinth beam and brick masonry with super structure in contact with the back fill earth and at the junction of the walls.The top surface of filled earth for flooring and the soil along with the perimeter of the building by making holes with the crow bar and poured 5% termicide “Chloripyrifos” and sprayingthe same termicide solution on the wooden frames and treating the other periphery of buildings etc., complete in all respects as per IS 6313 (part II) / 1981 and as directed by the departmental officers. 13 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc.,Rate to include all materials, labour charges, wastages ,placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by theClient / Engineer-in-charge. 14 For Column footing, plinth / grade beam, bed blocks, template surfaces, steps, piers, raft slab / beams and such other members 15 for plane surfaces such as rectangular or square rcc columns, sunshades, topand bottom slab of rcc boxing, etc. 16 Plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slab / beams and such other members 17 Providing and Laying M 30 Design Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Raft, Grade beam, Shear wall, RCC walls, Lift walls, Plinth beams, Column, footings, Grade slab, Roof slab & beam, Curved slab, beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box binders basement retaining wall, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. 18 For FoundationandBasement 19 For Ground Floor 20 For First Floor 21 For Second Floor 22 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete / PVC cover blocks to maintain the cover as required.Rate to include all bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 23 Supply and constructing Fly ash Brick (230 x 110 x 75mm) masonry in Cement Mortar 1:5 (One cement and Five M sand) in foundations, basement and superstructure usingFly ash Bricks of size 230x110x75mm etc. Rate to include all materials, labour charges, wastagesfor working at all levels with necessary lead and lifts, transportation charges, loading, unloading, scaffolding, staging, curing, fuel, consumables as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 24 For Ground Floor 25 For First Floor 26 For Second Floor 27 Providing two legged scaffolding using 15 cm dia casuarinas post of 4 M over all length (3 M Height + 0.5 M Projection + 0.5 M into the Ground) the distance between the two rows being 1.25 M and the spacing of posts being 2.0 M in both the rows with two horizontal posts with 0.5 M. Overlap on either side and braces at 2.0 M Center to center including longitudinal and transverse middle braces to step up and providing a platform with country wood planks of 40 mm thick and 1 M width, etc. in a complete from using coil and nails. 28 Upto 3 M Height 29 3 m to 5.5 m Height 30 5.5 m to 7.5 m Height 31 7.5 m to 10 m Height 32 10 m to 12.5 m Height 33 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc..with Cement Mortar 1:3 (1 of cement : 3 of P sand) according to the specification. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 34 Plastering 15 mm thick for external surfaces with Cement Mortar 1:5 (1 of cement : 5 of P sand) with water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed. The rate includingcost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 35 Plastering of 12 mm thick for Internal walls with cement mortar 1:5 (1 of cement : 5 of fine river sand)according to specifications. Rate shall include for providing GI chicken mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportation charges, loading, unloading, preparation of surface, necessary hacking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 36 Painting the new plastered walls with two coats for Interior Plastic Emulsion paint approved quality and colour over a priming coat, with two coats of wall putty including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 37 Painting two coats for Exterior surface with approved Exterior Plastic Emulsion paint approved quality and colour over a priming coat, including thorough scrapping, clean removal of dirt, etc complete and including necessary plaster of paris, putty, wherever required etc, complete as per standard specification. 38 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work 39 UPVC VentilatorSpecification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chamberedsections with wall thick of2mm.The EPDM rubber (black colour) covered with all over the edges of frame and shutter.The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The ventilator should be got approved from the Executive Engineer before use on work 40 Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification. 41 Painting the new Iron work with two coats of Ready Mixed Enamel Paint of aproved quality and colour over the existing priming coatincluding the cost all materials etc.,complete, in all floors and as directed by the Departmntal Officers. 42 Providing and fixing Vertical blinds , quality of approved make fabric made of 100% polyester woven fabric thickness 0.40mm with virtually maintenance free having plastic bottom chain thickness of chain-0.50mm and diameter-3mm, Plastic with metal bottom and suitable coating on exterior, including all fixtures and fittings complete in all respect as per design/color/shade including requisite installation brackets etc as required for installation at site with anchoring arrangements complete. 43 Supply and laying with best quality the following materials of Ruby Red, Raw Silk Granite Slabs (Super Fine Polished with Machine Cut Edges) of sizes 4’x2’ and above 18mm to 20mm thick Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 44 Supply and laying with best quality the following materials of Sinthetic Grey, Paradise and similar varieties Granite Slabs Granite Tiles - (Superfine Polished with Machine Cut Edges) of size 2’0” x 1’0” and above 10mm Thick including cuttingand edge polishing to be set in CM 1:3 (1 of cement : 3 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 45 Nosing for Granite Slab-Single Nosing 46 Grooving the Granite Slab 47 Paving the floor with Double charged Vitrified tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Executive Engineer before use on work 48 Paving the floor with design Antiskirt Ceramic tiles (colour and shade as directed) of size 305 mm x 305 mm x 6 mm in all floors over a base layer of cement mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 20mm thick laid in-situ and pointed with same coloured cement. 49 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 50 Supplying and filling the sunken slab area by BRICK-BATCOBA by adding CICO NO:1 of approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- Acrylic Polymer Based Naterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc Rate including all mater aaod and lifts, working materials, labour charges wastages with necessary lead and at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specificatior and as directed by the Client/ Engineer-in Charge 51 Including applying two coats not less than 2 nm thick of TAPECRETE- Acrylic Polymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No. 1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 52 Waterproofing: Providing and Applying CFTRI approvedtwo component flexible polymer modified acryliccementitious waterproofing coating with a mix ratio of(5 Liquid :7 Powder) to the RCC surface of the UGT/OHT tankapplied @ 2.2kg/m2 in 2 coats to achieve1.2mm DFT, having Elongation at break >120% asper ASTM D 412, Tensile strength >1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80N/mm2 as per ASTM D 4541, crack bridging upto 2mm as per ASTM C 836. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right anglesof wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completelyas per specification. Followed by applying 15 mm thick dimensionally stable fibrous reinforced cementitious structural grade dual shrinkage Polymer Mortar on as protective plastering @ 29kg/m2. The material having Compressive strength of 38 MPa at 28 days as per EN 12190, Adhesive Bond Test, >1.5 Mpa as per EN1542, followed by Water curing by sprinkling water for 3 times a day for 5- 7 days. Followed by applyingtwo component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 – 300 of US – FDA, having mixing Ratio (Base: Hardener: Water) – 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats. Ensure that this coating is applied over the protective plaster. The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02. The finished cost to include surface preparation completely as per specification 53 Finishing the top of roof with one course of Solar Reflective ceramic tiles of size 305 mm x 305 mm x 7 mm of approved quality in Cement Mortar 1:3 (One part of Cement and Three part of Plastering Sand (P- Sand)), 12 mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete 54 Supplying And Fixing Rubber Moulded Interlocking Paver Blocks Against Available Edge Restraints 83 mm Thick of Approved Design And Pattern of Strength 40 N/Sq.m. 10 mm Iss Metal With Minimum Cement Content As Applicable To M 40 Grade Concrete As Per Is-456-2000 Manufactures By Mechanical Or Hydraulic Machine Using Vibro- Compaction Process And Laid Over 50 mm Thick Laying Course (Bedding) Crushed Stone Sand (M Sand) Well Compacted By Plate Compactor With A Joint Width of 2 mm To 5 mm Including Filling of All Joints With Crushed Stone Sand (M Sand) And Compacting The Paved Surface With Plate Compactor Two Or Three Times Until All The Unit-To- Unit Joints Are Completely Filled With Crushed Stone Sand (M Sand) And Trimming The Edges Neatly Including All Labour Charges And Plate Compactor Charges Etc. Complete(Cost Inclusive of Crushed Stone Sand (M Sand)) 55 Supplying and fabricating of MS structural steel supports for various applications using channels, MS angle iron, bolts, nuts, anchor bolts etc., required for the work, cut to the size, bent to shape, welding, grouting etc., complete. Supports shall be powder coated with required colour for different system as mentioned above. 56 Providing Teak wood wrought and put up for frames of doors, windows and ventilators and any other similar joinery works including cost of country wood scantlings and labour charges for manufacturing the frames and fixing hold fasts and fixing in position etc. for all lengths as per architect designs. 57 Best Indian Teak Wood Panelled door in double shutters with frames 100x75mm at side,verticals and top. The shutters shall beof 40mm thick with moulded panels in 20mm thick planks,6Nos.of iron hold fasts fixed in c.c.1:2:4 6Nos.of butt hinges 125mm long including wind appliances, furniture,iron fittings,1No.of iron padlock 15cm long for locking arrangements and fixing inposition,etc.,complete.(ISI STD) 58 Varnishing the new wood work one coat with best shellac and with fine best varnish of approved quality varnish of teak wood natural finish including preparation of surfaces with sand papering in patty priming etc., complete complying with standard specification and as directed by the Departmental officers. 59 Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter 60 Best Indian Teak Wood panelled door shutter for single leaf door. The shutter shall be 40mm thick with moulded panels in 20mm thick planks inclusive of 3 Nos.butt hinges 125mm long,furniture iron fittings,1No.of jappened hooks and eyes 200mm long and 6mm thick and iron pad lock 15cm long including fixing inposition,etc.,complete 61 FALSE CEILING WITH GYPSUM PLAIN TILES Providing and fixing true horizontal level false ceiling using SAINT -GOBAINGYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at1200mm c/cmax by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm (Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying 62 Art work as per the direction of department official, over Oil Painting with first class quality and approved colour including a priming coat with thorough scrapping clean removal of dirt., etc., complete and including necessary plaster of paris, putty, etc., wherever required (Relevent ISI STD), including putty works. 63 Supplying and Fixing of English Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 64 Supplying and Fixing of Tamil Stainless Steel Letters of 25cm (10”)size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 65 upplying and Fixing ofEmblem (15”) Stainless Steel size and approved colour. The colour treatment process is achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes 66 Supply and fixing of Pre-fabricated Structural Steel, coated galvalume ROOFING SHEET of 0.5mm thickness with SMP coating with colour bond XRW coating, having minimum of 550 Mpa yield strength, Coating 150 GSM as per ASTM 792 or equivalent standard. The structural roofing Panel shall have 1020 mm effective width, nominal 30 mm crest height at nominal 250 mm centre to centre pitch with the embossment (share grove) on top & side of ribs for better composite action including Flashing for joints, and all incidental charges. 67 Supplying and erecting in position LIGHT DUTYSTEEL TRUSSES as per the drawing.The materials and design of the trusses should confirm to the relevant Indian Standard specification.The trusses shall be procured only from reputed manufactures oftrusses with prior approval of the Buildings Engineer and a certificate to the effect from the reputed manufacturers shall also be furnished with design.The rate quoted shall include the cost oftrusses.Base-plate with holding down bolts and nuts to RCC or Masonry works, roof purlins, rafters, purlin sleeves, the members fixing accessories etc., painting one coat of red-oxide paint and erecting in position etc., complete as directed during execution. The contractor shall also arrange to provide grouting for holding down bolts embeding the end purlins, to the gable wall wherever necessary etc.,The roof sheeting shall project 0.762m from the eves purlins. 68 Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete. 69 Providing, supplying, and fixing factory-manufactured pre-fabricated insulated roofing panels made of PUF (Polyurethane Foam) sandwiched between two metal skins, comprising pre-painted galvanized iron (PPGI) sheets of 0.5 mm thickness on both sides with 40 mm to 50 mm thick CFC-free polyurethane foam core of minimum density 40 kg/m³, having tongue and groove jointing with cam-locking arrangement for weather-tight sealing. Panels shall have minimum overall R-value of 6.5 and thermal conductivity not more than 0.022 W/m·K. Roofing to be supported over structural purlins/trusses using self-drilling screws with EPDM washers, sealants, fasteners, ridge covers, and flashing, complete. Rate includes supply, transport, hoisting, cutting to size, edge finishing, foam taping at joints, sealing, labour, tools, scaffolding, and all incidentals for a fully finished, insulated, and weatherproof roofing system as per manufacturer’s specification and as directed by the Engineer-in-Charge. 70 Brick Wall Cladding Nuvocotto Edge Cut Wall Tiles Natural Red finish in size 230mm x 76mm x 15mm 71 Brick JalliNuvocotto Camp Jallie Natural Red finish in size 200mm x 200mm x 60mm 72 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT 73 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 74 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 75 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 76 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 77 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 78 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 79 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,. 80 PLUMBING 81 Supplying and fixing in position White / Colour Glazed Model Floor Mounted European Water Closet of best quality and approved make with 100mm “P” or “S” trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings, such as, 15mm brass ball valve with polythene float with brass handle, unioncoupling connected by means of 40mm white PVC flush hand using indian adopter joint including all internal fittings, such as, 15mm bras connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition, etc., complete complying with standard specifications. (The EWC and flushing tank with all accessories should be got approved by the Executive Engineer before use on works) Floor Fitting. 82 Supplying and fixing Stainless Steel Health Faucetwith all the accessories etc, 83 Supply and fixing White without PedastalWash Hand Basin of size 550mm x 400mm with all accessories such as Cast Iron Brackets, 32mm dia CP Waste Coupling, Rubber Plug and Chain, 32mm dia B Class GI Waste Pipe, 15mm dia GM Wheel Valve, 15mm dia Nylon Connection, 15mm dia Brass Nipples,15mm CP Pillar Tap etc (The wash basin should be got approved by Executive Engineer before use on works). 84 Providing and fixing C.P. Angle stop cock of approved quality conformingto IS:8931 :15mm nominal bore 85 Providing and fixing Brass Chromium Plated Towel Rail 60cm long and20mm dia with Brackets etc,. 86 Providing and fixing Brass Chromium Plated Soap Tray of size 150mm x 100mm 87 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines. 88 75 DIA 89 110 DIA 90 Providing, fixing and testing of PVC waste pipe of agricultural sereis conforming to IS 4985 including all fittings like tees, elbows, bends, collars, coupling, etc jointing with solvent cement followed by application of leak proof adhesive like FRP paste laid on floors inside the toilets to the required slope including making necessary bores in walls / foundations / concrete slab as applicable, making good the bores with CM 1:3 or cement concrete as applicable, curing etc., complete. 91 40 DIA 92 Providing, fixing and testing of PVC floor- trap 110 dia with necessory of multitrap connection (heavy duty hinged type) with brass CP frame & cover (100 mm x 75 mm). Trap of 100 mm dia inlet and 75 mm dia outlet fixed on a bed of cement concrete etc.complete. (The frame and grating shall be approved by Architects) 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed On Wall) 94 20MM DIA 95 25MM DIA 96 Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : 97 25mm dia Cost of gate valve 98 32mm dia Cost of gate valve 99 Providing, installation, testing and commissioning approved make CIY-type Strainer conforming to IS standardwithnecessary companion flanges, neoprene gaskets(10Kg/sq.cm. pressure rating) nuts and bolts including all the accessories to complete the work as per the specifications. 100 32 mm nominal bore 101 Providing, fixing and testing of PVC soil, waste and vent pipe confirming to IS 13592 of SWR quality 6 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste, fixed to wall with properly fabricated MS bracket of suitable size, GI U clamps with bolts, nuts and GI washers complete, for soil and waste pipe lines.(Pipes Runningin the Shaft & below ground level) 102 75 DIA 103 110 DIA 104 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water Providing, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Pipes Runningin the Shaft & below ground level) 105 25MM DIA 106 32MM DIA 107 Providinging and fixing in position PVC Vent cowls of following dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 108 75MM DIA 109 110MM DIA 110 Providing and fixing GI. puddle flanges (IS; 1239) fabricated out of 6 mmthick M.S. plate of size 300 x 300mm plusdia of pipe of 750mm long pipe pieces fixed to RCC wall of water tanks. Including painting with two coats of primer complete as required. The entire fitting shall be hot dipped galvanized.(Rate As per Quotation) 111 32 mm dia 112 40 mm dia 113 50 mm dia 114 65 mm dia 115 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:(Rate As per Quotation) 116 Constructing in site of Inspection chambers comprising burnt brick/solid block masonry walls of 230 mm thk., built in CM 1:4 over M-15 CC bed of thickness 100 mm ,Heavy duty RCC precast cover (SFRC), benching in CC M-15, internalfaces plastered smooth in CM1:4, 15mm thick and outside Rough Plastered with CM 1:6, 15mm thick including necessary earth work excavation returning and refilling and disposing surplus soil as directed by the Engineer in charge. 600x600 mm size internal and depth will 450mm to 1200mm & 900x800 mm size internal and depth will 450mm to 1200mm. (Rate As per Quotation) 117 600x600 118 Making of core cutting in RC slab of maximum 150mm thick of following diameter. 119 a) 150 mm dia 120 b) 125 mm dia 121 Providing and fixing MS slotted angle iron brackets, hangers, MS grip bilts,universal clamps with thereaded rod,supports with necessary drilling holes to suit the insertion of pipe clamps, deburring etc., as per detailed drawing for supporting soil, waste and rain water pipes and water Providing pipes in shafts with suitable MS clamps, bolts, anchor bolts, nuts and washers fixed on shaft walls/outer walls etc., The quoted rate shall include with the cost of brackets galvanizing with zinc alloy of 0.08 mm thick conformed to IS 1239 etc., complete as directed by the employer. 122 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality.(600x600mm) 123 Providinging, installing, fixing, jointing, testing and commissioning of PVC Storm water pipe confirming to IS 13592 of SWR quality 4 kg / sq.cm pressure rated 10mm, including all fittings, like Bends, Tees, Elbows, Collars, junction, inspection doors, cowls, offsets, access pipes, jointing with rubber ring / solvent cementfollowed by application of leak proof adhesive like FRP paste,The quoted rate shall include necessary earth work, fittings,pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting,refilling, and making good the same complete as required. 124 110 DIA 125 Providing, fixing and testing of Terrace Rain water outlet (110dia) with all the accessories etc,. 126 INTERIOR 127 BOOK SHELF 1 - 2100 x 400 x 2100 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 128 MAGAZINE HOLDER - 600 x 250 x 1200 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 129 DISPLAY UNIT AT RECEPTION - 1200 x 300 x 600 Carcass are 16mm MR Ply with 0.72mm Backer Laminate on both Sides, Shutters are 16mm MR ply with One Side 0.72mm Backer Laminate & Front side 1mm Matt Finish with 2mm PVC Edge Band finish. 130 LEDGE 5000 x600 x 750 Panels are 16mm MR ply with 1mm Matt Finish on both sides with 2mm PVC Edge Band finish mounted to the wall. 131 4SEATERLEARNINGCENTRETABLE-2000mmx1000mmx750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thick 132 6SEATERLEARNINGCENTRETABLE-2400mmx1000mmx 750mm -TABLE TOP: 25mm pre laminated particle board with 2mm PVC edge banding. MS 120 LEGS: Pillar are made out of heavy duty CNC cut & bend section of 120 degree which is engineer designed, E250 grate of 2.5mm thic 133 READING CHAIR - Lounge Chair Uphostered in EPU Leather. Sleek Four Star Fixed Base With Revolving Function In Warm White Powder Coated Finish. Three Dimensional Lumbar Support Design. Model number SCML-SF30.1. Bosses Cabin or equivalent. 134 ROLLINGCHAIRS-Medium back chair with metal grey back frame, metal grey adjustable PU armrest (4D), moulded foam seat with metal grey shell, STG drive-by-wire mechanism with 4 position locking, polished aluminum alloy five-star base with metal grey PU castors. Model number CHT66SW. Bosses Cabin or equivalent. 135 SINGLESTUDYCHAIR:Multi-Purpose Chair Upholstered In Water Based PU Leather. Cushioned Seat and White Ash Solid Wood Legs. Model number SCMF-XCB33 - Latte Brown. Bosses Cabin or equivalent. 136 LOCKER & FOOTWEAR STORAGE- – 1950x375x470mmPLU main 2 DR numeric lock with envelop slot – 1950x375x470mm. Godrej interio or equivalent. 137 RECEPTIONDESK-1800mmx650mmx 1050mm- Reception Table In Matt White and Oak Laminate. IncludesStorage Cabinet and WireManagement Grommet OnDesk. Top Model number 28ROB003(BCRMB-OB 03). Bosses cabin or equivalent. 138 Seamlessly shift from warm, cozy tones to cool, vibrant whites (also known as tunable white or human-centric lighting) is an advanced JS3 Serial LED Connecting System LED lighting technology that allows users to adjust the color temperature of the light output — from warm to cool — to suit mood, time of day, or functional needs.LED Type: OSRAM SMD 3030Iceil™ Supply of OSRAM 24V LED Module Color Temperature: 2700K to 10000K with Iceil IP67 Drivers CRI: ≥90 – Delivers natural, true-to-life color accuracyMounting: High-performance aluminum rigid PCB– Ensures excellent thermal management and long lifespanConfiguration:– Each block features 4 high-quality LEDs– Optimized light spacing for shadow-free illumination– Viewing Angle: PMMA lens Ultra-wide 160° beam spreadDimmable: No Compatibility:DALI, Tuya Smart App, Alexa, & Google Home. Touch Panel, and RF Remote control optionsPower Consumption:– Only 4-6W per sq.ft– Energy-efficient yet high-lumen outputLighting Quality:– Uniform light diffusion across the stretch ceiling– Suitable for both translucent and printed membrane typesIceil™ Power Supply: Wide Input Range 100-305AC (Class I), Surge Protection with 6KV/4KV, Working temp. -20~ +45°C 20% ~ 90%RH, Metal case IP67, Power factor <0.98LED and Power Supply Warranty: 5 Years or 50,000 Hours (whichever comes first)Certifications: CE & RoHS Certified – environmentally safe and globally compliant Installation of pre-supplied LED lighting fixtures, associated drivers, and control systems, including all necessary mounting, wiring, terminations, and system integration by qualified technicians.The scope includes:Installation of LEDs as per lighting layoutMounting and secure placement of LED drivers and control gear in accessible locationsElectrical connections between LEDs, drivers, and controllers using appropriate cablingTesting of each circuit and commissioning of the full lighting setupRate Includes: Skilled labor, tools, basic fasteners, and all on-site installation efforts.. 139 Iceil™ supplies exclusively premium-grade of European Standard PVC Thermo-Stretchable Membrane, complying with BS1-D0 as per EN 13501-1 and Class A as per ASTM E84-2024 fire safety standards. The membrane is precision-cut to the required shape and size, with perimeter edges high-frequency welded with harpoon inserts. Installation is carried out using a durable aluminium profile framing system, ensuring a seamless, secure, and aesthetic ceiling solutionThickness 0.18 mmWeight 250–300 gsm ± 2%Light Transmission Up to 75% (for translucent type)Width Up to 5 meters (seamless); larger areas joined with invisible seamsStretching Method Thermal installation at ~50–60°C using hot air gas blower Fire Rating BS1-D0, as per EN 13501-1, ASTM E84-2024 Class A Explanation: B = Very limited contribution to fire, s1 = Little or No Smoke Production, d0 = No flaming droplets or particles Moisture Resistance 100% Moisture-proofUV Resistance Yes – does not yellow or degrade indoorsEnvironmental ROHS compliant, Phthalate-free, UL Certified - Tri-O-cresyl phosphate < 50mg per kgCertification Manufactured in ISO 9001:2015 certified factoryWarranty 10 Years (under standard indoor conditions) Installation of pre-supplied Stretch Ceiling System, including site preparation, profile fixing, membrane stretching, and finishing using specialized tools and skilled labor.The scope includesFixing of aluminum/PVC perimeter profiles as per approved ceiling layoutHeating and stretching of the pre-cut stretch ceiling membrane on-siteAlignment, tensioning, and seamless fitting of membrane onto the installed profilesIntegration of cutouts for lighting, sprinklers, air conditioning vents, speakers, etc.Final finishing, cleaning, and handover of installed ceiling areaRate Includes: Skilled labor, installation tools, on-site execution, and necessary accessories for completing the installation of the stretch ceiling. 140 The Iceil Wooden Box is built from durable MR/BWP-grade plywood, featuring a 12mm back board, 18mm vertical sides (150mm height), and dual 8mm flexible plywood layers for curved designs. The 150mm depth accommodates lighting and structural needs.Finish Options: White emulsion or PU-coated interior, or white reflective laminate; exterior customizable per client.Mounting: Reinforced corners, cross supports (wood/MS) every 2 ft, fixed with dash fasteners, threaded rods, or MS supports.Stretch Ceiling Compatibility: Suits Iceil’s PVC Harpoon Profile System with aluminium profiles for welded membranes.Lighting Integration: Base for rigid block LEDs with ventilation slots for heat dissipation. 141 Wall paper 142 Carpet Flooring 143 160A LT Metering Panel - Supply, Installation, Testing and Commissioning of CPRI approved make of panel, cubicle type, Free standing, Wall mounted, single front,14 SWG CRCA sheet steel, enclosed separate compartment for each feeder, front operated, Powder coated, indoor type dust and vermin proof, hinged lockable doors, complete with electrolytic grade copper bus bars,internal wiring, colour coding, ferrules, Panel mounting MS Channels, fasteners, etc., including all associated control wiring. The Breakerof 160A TPN MCCB and 1set of 160/5A CT with TNEB Metering provision and 1nos of 160/5A CT for APFCR . (Rate as per Quotation) 144 Supply and Erection of electrical panels Boards 145 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type Three Phase Changer Over panel of size (H 2100 X L 2000 X D 300 ) mm with suitable to accommodate 100A 4 pole Three phase Change Over Switch-1No. as incomer for EB Source and as incomer for DG Source, 6nos of 63A 4Pole MCCBs and 4nos of 32A 4Pole MCCBs compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 146 Fabrication, Supply, Erection, Testing and Commissioning of whether proof CRCA sheet steelmade up of 2mm powder coatedMCCB Indoor Type 50 kVAR panel of size (H 1800 X L 1800 X D 300 ) mm with suitable to accommodate Incomer 1 Nos 63A 4Pole MCCB, 7nos of 25A 4Pole MCCBs with 7% 1-10 kVAR Capacitor banks in compartment as O/G supply with the provisions to accommodate Busbar chamber and cable chamber with size of 25x6mm copper busbar 4 runs having three phase Multifunction meter with line indicators and with all necessary accessories with all other connected works etc. The panel made up of 16/18 SWG CRCA sheet steel comprising of 4 sections with separate sheet steel weatherproof and shock proof safety insulation system conforming to IE Rules with IP protection, and with the panel should be painting by powder coating finishing etc.,as complete and making good of the panel with neat finishing. (Switch make : L & T / ABB) panel should be earthing confirming ISI specifications. The panel should be erected on Anchor fastners, bolts and nuts for mounting the Indoor Panel as directed by engineer-in charge/department superior engineers. Including Bus bar support, Cost ofWeldding charges for mounting the panel, Rotary Handle, Spreader Terminal, Multifunction Meter digital type / MFM 5010 LED meter CI 0.5S 147 VERTICAL THREE PHASE MCB DISTRIBUTION BOARD WITH MCB : Supply and fixingof4way verticalTPMCBsheetsteel Industrial Type TP MCB DB with IP54 Protection of surface type fitted with bus bars and neutral links with1 No. of 63A FP MCB as Incoming and 4 Nos.of32A,10KA Triple Pole MCB in Flush with wall and making good of the concealed portion with earth connection.( Industrial Type TPMCB DB with IP54 Protections) 148 Supply and fixing of 7 segment8 way63A TPN MCB sheet steel distribution board (Higher end) with metal / acrylic doorcover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating one no. 4 pole incoming 63 A TPN MCB, 10kA, / Isolator and another separate 4 way for accommodating one no. 63 Amps, 30 mA, 4 pole ELCB / RCD (totally 8 ways in one segment) and 24 nos 6-32 A, 10kA, SP MCB / Isolators ( totally 24 nos.) for outgoing in 3 segments with label holder and provision for taking up cable for size not less than 35 sq.mm. withthe following in flush with wall with earth connection only. 149 Supply and fixing of 65 mm dia. (2 -1/2) GI pipe (class B) of 6 metre length with 300mm x 300mm x 6mm MS base plate duly welded at the bottom with concreting with construction of masonry pedestal with suitable SMC box with door arrangement to house 6A SP MCB switch, 2/4 way connector on suitable hylem sheet and supply and fixing of 90W LED Streetlight fitting with LED (Higher end) with 1 metre 32mm dia. GI pipe (class B) Complete with suitable MS clamps for LED street light fitting and SMC box with PVC unsheathed copper leads from SMC box to fitting and with painting of suitable colour 150 Supply and Fixing of24W Ceiling Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 151 Supply and Fixing of11W Bulk Head Lightwith PVC unsheathed copper leads from terminals to the fitting.(Make : Philips/Crompton/Havelles ) 152 Supply of surface-mounted 24W LED wall lights to the ideal solution for a variety of indoor lighting applications. Direct illumination of the wall and surrounding surface, as well as accent lighting for vertical structures. Featuring an aesthetically pleasing, robust construction, these lights are built to withstand all weather conditions, ensuring long-lasting performance and durability • Luminaire body made of extruded aluminium alloy (grade 6063) with die cast aluminium components and non corrosive SS fasteners • Non yellowing UV stabilized translucent polycarbonate diffuser • Luminaire integrated with 24W LED • Die-cast aluminium mounting base for easy installation onto the wall • Surface mounting on wall using hardware after connecting to the power supply • IP : 65, IK : 08 • Cable entries for through-wiring of mains supply cable • Integral constant current power supply • CRI ( Ra) : >80 • Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply • Available CCT : 2700K, 3000K, 4000K, 5700K. Driver Power Supply : Integral, Input Voltage : 230-240Vac, Frequency : 50-60 Hz, Power Factor : ≥0.95, THD : <10%, Surge Protection : 4KV, Efficiency : >85%, Symmetrical Light Distribution.Product Finish options: Pure polyester powder coated RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. CE & BIS Certified. Inhouse NABL accredited lab. Brand Name : Philips, Product SKU : 919215850004 153 Supply of LED Linear Pendant luminaire is a versatile solution for projects that demand high quality of the lighting system and high visual comfort. With its modular design, the Revo-L can be used as an individual fixture or as a combination of luminaires put together in continuous lines • Luminaire made of extruded aluminium for better thermal management • polycarbonate diffuser for optimum optical performance, • Hexa-cell (Matte Black) secondary reflector • Suitable for surface and suspended mounting • Supplied with standard suspension kit (1metre).• Cable entries for through-wiring of mains supply cable • Integral power supply • Suitable for operation on 240V,50Hz single phase ac supply• Driver Power Supply : Integral, Power Factor : >0.90, THD : <10%, Surge Protection : 4KV-6KV, Efficiency : >85%, IP 44 Rating.• Dimension: 1188 x 36 x 75, 2365 x 36 x 75, 3540 x 36 x 75.• Wattage Options : Upto 40W, Upto 80W, Upto 120W.• Mounting: Pendant Mounting, Pendant Mounting, Pendant Mounting, Surface Mounting, Surface Mounting, Surface Mounting • Product Finish options: Pure polyester powder coated, RAL 9004 Signal black, RAL 9007 Grey aluminium, RAL 9016 Traffic White • CE & BIS Certified • Inhouse NABL accredited lab. Philips SP170P LED25S-6500 PSU W5L113 OD WH Smartbright Linear 154 Supply of Input power : 8W LED Bollard luminaire designed for surface mounted. Symmetrical light distribution. Luminaire madeof extruded aluminium alloy (grade 6063), die-cast aluminium of high corrosion resistance and non corrosive stainless steel fasteners. Translucent polycarbonate diffuser. Pressure die cast aluminium mounting plate Ø100.5mm x 4mm thick with 2 elongated holes 15 x 10 to suit M8 bolts at PCD55 for surface mounting on floor. The base plate have a cable entry hole of 70 x 24 mm dia at the center. Single cable entrance via PG7 cable gland. Protection class IP65. Mechanical resistance IK08. Pure polyester powder coated RAL 9004 Signal black, RAL9007 Grey aluminium, RAL 7016 Anthracite grey, Graphite grey. Available colour temperature 2700K / 3000K / 4000K / 5700K. Colour rendering index (CRI)>80. K-Lite LED module with expected service life of at least 60,000 operating hours. Prewired with LED driver and suitable for operating on 240V, 50Hz single phase ac supply. Driver efficiency >80%, Power factor >0.9, THD <10%, Surge protection 2.5KV. Luminaire dimension : 106mm diameter x 565mm height. CE & BIS Certified. Foundation Bolt - 2 Nos of M8 Foundation J Bolt Length 150mm, 2 Nos of (Spring Washers, Plain Washers and Nuts) for each BoltInhouse NABL accredited lab. PHILIPS Bollard BCP100 LED 10W PSU GR L 750mm Solar Light 155 Supply of LED Linear Lighting to suit ceiling / wall is a slim and elegantly designed fixture, suited for varied applications offers a uniform, glareless and soft lighting.Al. Profile Housing Dimension: 1000 x 17 x 8, 2000 x 17 x 8Mounting: Surface Mounting, Product Finish: Anodized Aluminum• Luminaire made of extruded aluminium for better thermal management • PC clear / semi clear matte diffuser for excellent diffused lighting experience throughout the life of the fixture • Designed for mounting on ceiling / wall • Cable entries for through-wiring of mains supply cable • To be used with LED strip & power supply unit of suitable rating. Brand Philips Profile Shine 240 LEDs/m LED Strip | 3000K Warm White | High Brightness Linear Strip for Cove, False Ceiling, Architectural, Ambient Lighting 156 Supply of 24V 2835 Flexible LED Strip, 12W/m, Non-Integral, CCT: 2700K, 4000K, 6500KDimension: 5m / Roll, IP : 67, Brand Name : K-Lite, Code : 7289 or equivalent 157 24V Power supply, IP 67 Rated SMPS suitable for 24V LED Strip lights. Wattage: 150W, 24V Series Waterproof IP67 Power Supply24Vdc 6.25 Amps 150W Power unitDimension: 313 x 43 x 34IP : 67,Brand Name : K-Lite, Code : 8198 or equivalent 158 Supply and fixing of Fans and Air Circulator 159 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star rated complete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 2.5 metre down rod with fan clamp, and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 160 Supply and fixing of 600mm wall mounting Air circulator and wiring to the near by point with 1.5 sqmm FRLS , PVC insulated copper wires, including necessaryaccessories and hardwares as required. (SD -563) 161 Supply and fixing of 300mm(12)sweep (Heavy duty) AC Exhaust fan complete with necessary wall opening and making good of the wall and wiring to the near by point with 1.5 sqmm FRLS PVC insulated copper wires including necessaryaccessories and hardwares as required. 162 Supply and fixing oflouvers shutter arrangements for 300mm(12)sweep (Heavy duty) AC Exhaust fan complete 163 Supply and laying of following XLPE armoured LTUG cable in a trench/Tray with suitable cable tie tag etc as required. 164 Supply and Laying of 3 1/2 x 50 sq.mm. PVC Al.Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 165 Supply and Laying of 4C x 16 sq.mm. PVC AL. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.Main Panel to DB 166 Supply and Laying of 3C x 2.5 sq.mm. PVC Cu. Armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make goodMain Panel / DB to Street Lights 167 Supplying & Laying 120mm/103.5mm HDPE Pipe as per requirements including excavation & refilling. 168 Supply and fixing of double compression brass cable gland for following Aluminium conductorXLPE insulatedarmoured cable of 1100 V grade with earth connection. 169 Supply and fixing of brass cable gland for3 1/2 Cx 50 Sq.mm PVC LTUGAl. Armoured cable with earth connection 170 Supply and fixing of brass cable gland suitable for4C x 16 PVC Al. Armoured LTUG cable with earth connection. 171 Supply and fixing of brass cable gland for 3C x 2.5 sqmm COPPER cableLTUG cablewith earth connection. 172 Supply and providing cable end termination of the following sizePVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (copper sockets for copper cables and Alu. Sockets for alum. Cable) 173 Supply and providing cable end termination of3 1/2Corex 50Sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping etc., with electrical connection complete. 174 Supply and providing cable end termination of 4 C x 16sq.mm PVC LTUG Al. Armoured cable with necessary aluminium cable sockets by crimping with electrical connection complete. 175 Supply and providing cable end termination of 3C X 2.5 SqmmPVC LTUGCopper cable with necessary copper cable sockets by crimping etc, with electrical connection complete. 176 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End (SD-375) 177 Wiring with 2 x 4 sq.mm. (56/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 16A one way module switch and 1 no. 16A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for Concealed PVC pipe power Plug point ( 8 points / Coil)Higher End (SD-385) 178 Supply and fixing of 25A Flushtype Wall Socket 25A DPMCB complete set for ACPlug inflush with wall with earth connection (For AC Plug) 179 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigidpipe Concealed inwall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copperwire and making good of the concealed portion withsuitable colour. ( SD 430 ) 180 Supply and Run of 2 Run x 2.5 sqmm and 1R of 1.5sq sqmm PVC insulated SC unsheathed Cu.Conductor of 1100V Grade in suitable Pvc conduit pipe onconcealed wall and ceiling with continuous earth wire connection with painting of suitable colour. 181 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 50mm and 2 mtr long earth electrode of low carbon steel rod with 100 micron bonding and 25 kgs of carbon based environment friendly backfill compound and suitable clamp andwithcopper earth plate of size 125mm x 50mm x 6mm with necessary funnelling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonrySD-233 182 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection 183 Supply and Run of 1 of25.6.25 mm Al. Flat on wall / floor / ground for earth connection. 184 Supply and Run of 1 of25.6.25 mm Cu. Flat on wall / floor / ground for earth connection. 185 Supply, Installation, Testing and commissioning of 40 channel NVR with 4TB HDD * 4nos, Up to 40-ch 8 MP IP cameras can be connected, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by up to 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1/VGA1 outputs provided  HDMI1 Video output ) resolution Storage and Playback, Up to 4SATA interfaces and 1 eSATA interface for HDD connection, Support upto 6TB capacity for each HDD, Smart search for efficient playback.(Make: Hikvision/Dahua/Panasonic) 186 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse.All including suitable camera stand and accessories. (Make: Dahua/Panasonic) 187 Supply, Installation, Testing & Commissioning of IP Network TDN Low-Light IR Dome Each Cameras, 1/2.8 CMOS,4 MP 2592 x1520 or better , triple stream, Min. Illumination required 0.005 Lux/F2.0 (Color,30IRE), 0 Lux/F2.0 (IR ON), 140dB True WDR, triple stream,3 to 12 mm, F1.4 to 2.8 , MFZ, Backlight Compensation, Highlight Compensation 3DNR, Privacy Mask, Internal/External Smart IR LEDs with up to 50m IR distance, H.265& |MJPEG, Inbuilt Video Analytics: Smart Motion Detection, Intrusion Detection, People Counting, Multiloitering, Face Detection, Line Crossing, Missing Object detection, [Unattended Object Detection. THe camera shall have inbuilt cyber security FIPS Chipset.Audio Stream Full Duplex, 1TB SD card support, IP 67 & IK10, Alarm: 1 In & 1out, PoE, H.265 High Profile and MJPEG, PoE Class . Certifications: ONVIF Profile S,G,T & M compliant, NDAA 889 UL, CE, EN, FCC & RoHS compliant and with all accessories and as per detailed tender specifications. 188 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN o) Magic remotep) Dimension 1242 x 724 x 55.1min(37). (Make: Sony/ LG /Samsung). 189 Supply and Clamping of CAT 6 armoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylenev. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 190 Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point( Point to Point ) Crimping, Testing and arrangement charges. 191 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 192 Supply and Fixing of Rack with Accessories -Higher end 12 U Rack with LNS unit and fan extra for the above rack. 193 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 194 PA SYSTEMS 195 Supply,installation, testing and commissioning of 30W High efficiency ABS horn loudspeaker with weather protectin IP 65Max Power : 45 W, Rated power, 30 Watts, Power tapping, 30/15/7.5W-Effective frequency range (-10 db) (-380 Hz to 5 kHz) - SPL at rated power (1 khz) 126 dB- Self extinguishing acc. to UL 94 VO - IP 65 acc. to IEC 60529, safety acc. to EN 60065. (Make - BOSCH) 196 Supply, installaion, testing and commissioning of 240W mixer amplifier with following features : inbuilt bluetooth for audio streaming, sports audio playback from USB pen drive, 4 microphone/line inputs, plus music source input, insert features to use as a pre/power amplifier, Optional 2 tone chime generation for input 1 technical specifications - Frequency response 80 Hz to 18 kHx (+1/-3 dB W - 10 dB ref. rated output) - Distortion <1% @ rated output power, 1 kHz bass control Max +/- 8 dB Treble control max +/- 8 dB. (Make - BOSCH) 197 Supply, installation, testing and commissioning of Goose Mic 198 Supply and installation ofHandheld microphone with a dynamic transducer element that shall be designed for high speech intelligivility. It should have a rugged enclosure is both stylish and easy to use in a wide range of public and sound reinforcement applications. Polar Pattern unidirectional, frequency range 80 hZ to 12 kHz, Sensitivity 1.7mV/Pa +/- dB, Rate out impedance 600 Ohms. (Make BOSCH) (Market rate) 199 Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., asper standard methods and as directed by the Departmental Officers. 200 Supply and Installation for 2KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2Hours back up 201 Supply and erection, testing and commissioning of 2.0 TR (6000K.cal/hr) ABS Split type Air conditioner (3 star rating)confirming to IS : 1391(part-2) 1992 with Admt No.1 fitted withhermetically sealed air compressor operating on refrigerant R-410A suitable for wall mounting for operation on 230V 50 HZsingle phase AC supply inverter technology with capable of thefollowing performinga) Coolingb) Dehumidifyingc) Air circulatingd) Filteringe) Refrigerant pipe lines – 6 mtr lengthThe installation works for the above split type AC units includethe following1. Mounting / fitting indoor and outdoor units at theirrespective locations2. Laying refrigerant pipe line of required length notexceeding 6 meters distance & connecting both units afterdrilling hole/holes in the wall is required, thickness of the coppertubing shall not be less than 0.7 mm3. Installing the section pipe with expanded polythene foamtubing4. Laying drain pipe to throw out the condensate water beingformed within indoor unit5. Leak testing the entire system unit6. Charging refrigerant gas in the unit7. Suitable electrical wiring with to be provided with 2.5sq.mm PVC insulated copper wire between indoor and outdoorunit upto 6 meter length and upto switch within 3 meters oflocation of indoor unit. (Like (Carrier / Voltas / Blue Star /Equivalent) as directed by the department officers 202 Supply and fixing of 5 KVA slim and wall mounting (V Guardmake ) double booster voltage stabilizer for operation on 170-230V 50Hz single phase AC supply capable for 2 TR split ACwith necessary inter connection and earth connection as directedby the departmental officers. 203 LANDSCAPE 204 Supplying of plastic Potted plants Anthurium size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 205 Supplying of plastic Potted plants Bogainvillea size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 206 Supplying of plastic Potted plants Ficus ponda size of dia 12 inch including loading and unloading charges, transportation, etc as directed by the site in-charge 207 Providing & laying spreading & Compacting graded stone aggeragate of size 45mm to 22.4mm, 22.4mm to 2.36mm & 2.36mm to 75 microns to Wet Mix Macadam (WMM) specification including premixing the material with water at OMC in Mechanical mix plant carriage of mixed material by tipper to site, laying in uniform layers with paver in Sub base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density, rate including the cost & conveyence of all materials, labour charges for spreading, watering, rammed & consolidation and other tools & plants employed for the work etc., all complete and as directed by the departmental officers as per MORTH specification 406 IV Revision 208 Supplying and filling with M-Sand well watered rammed, and consolidated complying with relevant standard specifications etc., complete and as directed by the departmental officers. 209 ProvidingandlayingofBlackGraniteCobbleStoneflooringof approvedmake,inallcoloursandshades,laidon20mmthick cementmortar1:4(1cement:4coarsesand),jointingwithgrey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 210 SupplyingandlayingGrassPaverblock M40grade Providingand layingof 63mm thickhighstrengthtypeconformingIS15658- 2006ofrubberizedinterlockingpaverlockinsizeofminimum compressivestrengthof40N/mm2inuniformshapeofapproved maketobelaidinflurringbonepatternwithsandcushionbelow theuniformshapofapproved nonskittingsurfaceinthetopand therateincludinglevellingthebasepreparationof paversassub base,sandcushion150mmthicklaying outofpavementcutthe piecestofixtheedgevibringthepavers,sweepingtranporting loadingunloadingoflayingpaverblockasperstandard specification,.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
33.
Public Administrative Department #10224642 Price Bid
Tender For Proposed Construction Of Thirumana Mandpamfor 300 Person Capacity; 1 Description 2 Earth work excavation for foundation in all classes of soils and sub soils and todepth as may be directed except in hard rock, requiring blasting, including initialleads and lifts and re-filling the sides of foundation, with excavated earth in 150mm layers well watered rammed and consolidated, including depositing surplus earthclearing and levelling the site, shoring shuttering baling outwater wherever necessary etc., complete complying with standard specification. 3 Boring, providing and Installing cast in-situ single under reamed piles of specified diameter and length below the sand and lime mix pile 300 mm diameter and below the foundation to carry a safe working load not less than specified, including the cost of materials, machinery and labour charges etc., all complete 4 Refilling with excavated earth other than crushed stone sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officersin layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification 5 Supplying and filling in foundation, basement, etc with filling sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 6 Cement concrete 1:4:8 (one cement four sand eight aggregate) using 40mm gauge hard granite broken stone jelly for foundationincluding cost and conveyance of all materials labour formixing,l aying, compacting, curing, dewatering, side shuttering, wherever necessary including curing etc.,complete complying with standard specification and as directed. 7 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, RCC floor slab, roof slab, beams, lintels,Rectandular or square columns, sunshades,vertical slab, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid) 8 Column /footing, Grade beamEtc 9 Roof slab and Beams 10 Column and sunshade 11 Providing and laying in position, Standardised concrete mix M-20 grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/m3 and maximum water cement ratio of 0.55, including admixture (plasticiser/super plasticier) in recommended proportions as per IS:9103 to accelerate, rated settingof concrete improve workability without imparing strength and durability without (5 cum) 7730kg, of 20mm machine crushed stone jelly and with about (3.30 cum) 5156kg, of 10 - 12 mm machine pressed stone jelly and with about (4.79 cum) 7670kg of sand, but excluding cost of reinforcement grill an fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibraters, finishing, curing etc., and providing fixtures like fan clams in the RCC floor/ roof slabs where ever necessary without clamping etc., complete as per the standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS standards. (No separate payment will be made by the Department for the excess usage of materials). 12 Foundation and basement 13 Ground floor 14 First floor 15 Second floor 16 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire) 17 Brick work in following Cement Mortar 1:5(one cement and five sand) using best quality of country bricks of size 8-3/4 x 4-1/4 x 2-1/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 18 Foundation & Basement 19 Brick work in following Cement Mortar 1:6(one cement and five sand) using best quality of country bricks of size 8-3/4 x 4-1/4 x 2-1/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 20 Ground floor 21 First floor 22 Second floor 23 Brick partition walls of 11.50cm thickness using best quality II class Ground moulded chamber burnt bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 24 Ground floor 25 First floor 26 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers 27 Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 28 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 29 Finishing the top of roof with one course of machine pressed tiles of size 200mm x 200mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stoneSand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers 30 Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mmof approved colour, shade and quality laid in cement mortar 1:3 (one cement and three crushed stone sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 31 Paving the floor with joint free rectified glazed ceramic flooring tiles of size 305 mm x 305 mm x 8 mm of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 32 Dadooing walls with following best approved quality, white / colour glazed tiles ofsize 300 mm x 450 mm x 8 mm in Cement Mortar 1:2 (One Cement and Two crushed stone sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. 33 Painting two coats of newly plastered wall surface with Water based Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 34 Supplying and fixing of Teak wood frames 127x76 mm size including cost and conveyance of all materials and all labour chargesetc., complete as per the standard specification. (below 2 m in length) 35 CRCA pressed steel Box section 18 gauge or 1.25 mm thick for door frames including providing holes and fixing wooden blocks for fixing furniture and fittings. N-0303 with powder coated primes. 36 Supplying & fixing Teak wood temple type door (Temple pattern ornamental doors with high quality teak wood (country) with 2 minimum to 7 maximum thick ornamental frames, 2 thick to 5 thick kamala (flower planks), creeper, birds, animal figures sculptures, etc., back side 1 thick to 3 plank including necessary carving, shaping, wastage, etc., as per approved plan and design. (page.no.163, 2a))including all materials, labour charges for manufacturing and fixing in position including all furniture fittings etc., complete complying with standard Specifications. 37 Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops,3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers. Single Leaf 38 Supplying and fixing solid core particle board flush shutter of nominal thick of 35 mm with necessary T.W. internal lipping conforming to IS 2302 with both sides alround commercial ply 35mm thick including supplying and fixing cost of wind appliances and furniture fittings such as 1no .200x12mm aluminium tower bolt 2nos. 150x12mm aluminium tower bolts 1no. 250x16mm aluminium aldrops, 3 nos. 200mm ‘D’ type aluminium door handle and door stopper with bush etc., complete as directed by the departmental officers.Double Leaf 39 FRP door Sutter with FRP door frames made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and solid core FRP shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. M-0394 40 Supplying and fixing of PVC Sliding Door with Roller. M-0393 41 UPVC WindowSpecification:SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profilethe size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work M-0674 42 UPVC VentilatorSpecification:SupplyingandfixingUPVC(Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profilethe size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles arereinforcedwith GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned.Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work M-0675 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase near wet riser using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mmdiaof1.60mmthickweldedtotherailing.The supports will be groutedinto the wall and provided with 93.00mm thick Stainless Steel circular base plate of 304 Grade. The rate shall included for grouting into concrete with necessary supportingarrangementsthehandrailinfloor polishing buffing, bonding, cutting, grinding, conveyance, welding charges, electrical charges, etc. complete(M-0652) 44 Supplying and fixingmild steel grill Gate including costconveyance of all materials and fixing in position including priming coat etc complete with standard specifications. 45 Supplying and fixing of best quality 110mm Dia PVC rain water pipes including cost and conveyance of all materials and labour charges for fixing in position etc., complete. 46 Best varnish two coat for wood workincluding all materials, labour chargescomplete complying with standard Specifications. 47 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 48 Supplying and fixing in position European water closet of colour glazed earthen ware of approved quality with P trap or S trap with double flapped sheet and sheet cover with brass hinges and 10litre capacity PVC low level flusing tank with all internal fitting confirming to IS:2556 Part XII with sand cushion and forming flooring alroundthe closet using 40mm broken brick jelly in lime concrete 1:2:5 ( one part of lime, two parts of sand and five parts of brick jelly) 100mm thick and finishing the top to required slope and including giving necessary connectionto cast iron soil pipes/ PVC pipes by dismandling brick masonry, reinforced cement concrete roof/floor slab and making good the disturbed portion to original condition without quality with P trap or S trap confirming to IS:2556 - leakage etc., complete complying with standard spcifications. 49 Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 50 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.)(S.no.125a, P.No.43) 51 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 52 Painting new iron works such as gate, steel doors windowsventilatorswithtwo coats of approved quality and color of synthetic enamel paint over one coat of zinc chromite primer in allfloor etc, complete complying with standard specifications. 53 Electrical Arrangements 54 Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoires with metal box and 6A 1way modular Switch in flush with wall with suitable modular front plate cover for making good of the concealed portion for PVC concealed light point /fan point for Electronic Regulator) (4 Points Per Coil) (Anchor Roma/Equivalent)( DATA A) 55 Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plateand making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 5 points / Coil) Lower End (DATA B) 56 Wiring with 2x1.5 sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessoireswith metal box and 6A 1way modular Switch in flush with wall with suitable modular front plate cover for making good of the concealed portion for PVC concealed light point /fan point for Electronic Regulator) (6 Points Per Coil) (Anchor Roma/Equivalent) (DATA -C) 57 Supply and fixing of single box type 420 W LED fitting with TW round blocks on wall or celling with PVC unsheathed Copper leads from terminals to the fitting. (DATA - D) 58 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 300mm down rod on the existing clamp (SD 110 ) 59 Supply and fixing of 1200mm (48) AC ceiling fan complete with stepped electronic 300W regulator with 1 meter down rod on the existing clamp (SD 107) 60 Supply and fixing of 300mm (12) sweep (light duty) AC exhaust fan complete without provision of hole in the wall(SD 115) 61 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep (light duty) AC exhaust fan (SD 120) 62 Supply and fixing of 375mm (15) sweep (heavy duty) AC exhaust fan complete without provision of holes in the wall (DATA E) 63 Supply and fixing of louvers shutters arrangements for 375 mm (15) sweep (light duty)AC exhaust fan.(SD - 121) 64 Supply and fixing of9 W LED bulb for BH point(DATA F) 65 Supply and fixing of WT bulk head fitting with guard suitable for 9W CFL LED Bulb with electrical connection. SD 84 66 Supply and fixing of Havells LED Low Bay 50W Fitting with MS Clamp Set with Bolt and Nut and to be suspended with SS Chain 32 mm width with End Hooks with PVC unsheathead Copper leads from terminals to the fitting. (DATA H) 67 Supply and fixing of 3 nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 390) 68 Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 40 A DP MCB Isolator as incoming and 6 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Lower End (SD 515) 69 Supply and fixing of 1 no.6/16 A two module socket , 1 no. 16A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 402) 70 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no. 6A one module switch with module cover plate (plastic) on suitable module concealed Box ( GI ) in flush with wall with connections. Lower End (SD 378) 71 Supply and fixing of Four pole sheet steel enclosure with 1 no 30 A FP isolator on wall and necessary connection for motor control (DATA I) 72 supply and fixing of 24W LED 2x2 square type Recessed fitting with LED (Lower end) on false Ceiling with suitable hanging support from ceiling with PVC unsheathed copper leads from terminals to the fitting. (SD 440) 73 Wiring with 3 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A two way module switch with module front plateand making good of the concealed portion with suitable colour for Concealed PVC pipe Stair case Light point Lower End (DATA D) 74 supply and fixing of 30W LED street light fitting with LED (Lower end) with 25mm dia. GI pipe (class B) with 1 no.25mm GI bend complete on the existing post/ on wall with PVC unsheathed copper leads with MS clamps and with painting . (SD 447) 75 Supply and fixing of 25 A flush type wallsocket in sheet enclosure with 32A DP MCB in flush with wall with earth connection (For AC Plug) (SD 143) 76 Supply and fixing of Havells JETAALBA - FLOOD LIGHT -70W LED Fitting with Necessary Wall Grouting clamps with Fixing bolts on ceilling with PVC unsheathed Copper leads from terminals to the fitting. (DATA J) 77 Supply and fixing of 450MM 18 Almonard Walla Fan on wall with connection. (DATA K) 78 Supply and fixing of 4 way vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63 A 4P MCB Isolator as incoming and 12 nos. 6A to 32A SP MCB as outgoing in flush with wall with earth connection only. Lower End (SD 574) 79 Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2 X 2.5 Sq.mm Copper Wire and making good of the concealed portion with suitable colour. (SD 337) 80 Supply and Run of 2 of 4 sq.mm. (56/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour.(Data L) 81 Supply and run of 4 of 6 sq.mm. (84 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 2 X 2.5 Sq.mm Copper Wireand making good of the concealed portion with suitable colour (Data M) 82 Supply and fixing of automatic electric water heater of 25 litres capacity suitable for 230V 50 c/s AC supply on suitable MS clamps with 3 core flex wire but without plumbing connection (SD 103) 83 Supply, erection,testing and commissioning of 1.5 Ton(4500 K.Cal/Hr) ABS Plastic split type Air conditioner confirming to is : 1391(part 2) 1992 Amdt No.1 to 2 fitted with Rotory compressor operating Refrigerant R.22/ Non CFC suitable for wall mounting for operating on 230 voltrs, 50 HZ single phase AC supply with star rating of 3 as per BEE specification and capable of performing the functions of1) Cooling 2) De humidifying 3) Air circulating4) filtering. 84 The installation works for the above split type AC units includes the followings. Mounting/fitting in door and out door units at the respective locations. 85 1. Laying Refrigerant pipe line of required length connecting both units after drilling hole/holes in the wall if required. Thickness of copper tubing shall not be less than 0.7mm. 2. Insulating the suction pipe with expanded polyethylene foam 5 mm tubing. 3. Laying 15mm dia Flexible PVC drain pipe to throw out. The condensate water being formed within Indoor unit. 4. Leakage testing the entire system with outdoor unit stand.5. Charging Refrigerant gas in the unit.6. Suitable electric wiring to be provided with 2.5 sqmm. PVC insulated copper wire between indoor and out door units up to 6 meters length and up to Switch within 3 meters of location of in door Unit. (Carrier/voltas) (DGS & D Rates) M 1986 86 Supply and installation of 4 KVA Capacity Automatic Voltage Stabilizer with time delay relay (M-1988) 87 Supply and Laying of 3 1/2 x 70 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (SD 662) 88 Supply and clarnping of 3-1/2 x 70. PVC LTUG armoured cable on post or on wall with MS clamps (SD 203) 89 Supply and frxing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection (SD 167) 90 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete (SD 216) 91 Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with continuous earth wire connection 14 SWG TC wire with painting of suitable colour (SD 55) 92 Supply and fixing of 100 A Three phase 500V 4 Pole Change over Switch on suitable angle iron frame work with MS cable entry boxes with earth connection only (SD 649) 93 Supply and fixing of TNEB metre board suitable for 3 phase 100A service connection made up of suitable angle iron frame work of size 2 feet x 1-1/2 feet using angle iron of size 1-1/2 x 1-1/2 x 1/4 rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12 mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 100A fuse units (500V) 1 no. neutral link, copper earth flat of size 1 x 1/4 with inter connection of EB meter to fuse units by 16 sqmm PVC insulated copper wire with earth connection complete, (SD 133) 94 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry (SD 211) 95 Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection (SD 371) 96 Supply and fixing of 8 way vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 100 A 4P MCB Isolator as incoming and 6 nos.63A TP MCB and 2 Nos 32A TP MCB as outgoing in flush with wall with earth connection only. Lower End(DATA N) 97 Supply and Run of 4 of 16 sq.mm (101/0.45) PVC insulated SC unsheathed copper conductor of 1100 V gradeon 7/20 GI wire for service connection mains (DATA O) 98 Supply and Run of 4 of 16 sq.mm (101/0.45) PVC insulated SC unsheathed copper conductor of 1100 V grade in25mm dia GI pipe (class B ) suitably bent at both ends with necessary angle iron upright and end support for service connection mains (DATA P) 99 Water Supply Arrangements 100 Supplying laying and jointing 50mm P.V.C pipes ( 10Kg/SqCm ) of approved quality and best variety conforming to I.S.S and with I.S.I mark, of the following sizes including cuttingand fixing to PVC specials using Adhesive but excluding cost of such specials makinggood the dismantled portions to original condition with necessary brick work and plastering wherever necessary with necessary scaffolding charges. below ground level upto 0.60m height. 101 Supplying and fixing in best 50mm Gate valve and all materials labour charges and cost of conveyance all including cost etc.,complete. 50mm Gate valve should be got approved by the Executive Engineer before use on works-1.00 No 102 Supplying, laying and jointing 25mm PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 103 Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works) 104 Supplying and fixing position CI Nahani Trap / Floor Trap of the following 100 x 75mm sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of crushed stone sandand five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) 105 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 100mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 106 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 107 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks) 108 Supplying and fixing in position CP shower rose with CP stop cock arrangement of size 15mm dia inlet and 100mm outlet to the pipe line with necessary cutting, threading and jointing using shellac etc., complete complying with standard specification and as directed by the departmental officers (The CP shower rose should be got approved by the Executive Engineer before use on works). 109 Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements 110 50 mm dia 111 Elbow 112 Bend 113 Tee 114 Coupler 115 25 mm Dia 116 Elbow 117 Bend 118 Tee 119 Reducer 25 mm x 20 mm 120 Coupler 121 Supply and providing 2000 litres capacity Priming Tank made up of PVC. Make: SINTEX / EQUIVALENT M-0540 122 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level 123 Supplying PVC Specials (with working pressure 10 kg. / sq.cm.) in water supply arrangements (both in internal and external water supply arrangements 124 110 mm Dia Special 125 Elbow 126 Elbow with Door 127 Bend 128 Tee 129 Tee with Door 130 Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers 131 Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT M-0851 132 Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT M-0852 133 Bore well 134 Drilling od 150mm dia pilot bore well in sedimentary areas by using CalyxRig any where in thanjvur district including transportation to anoher plce in alluvial soil or sedimentary strata of clay and sand stone ,shale ,pepples boulders ect by taking a pilot bore well of 140/150mm dia and then enlarging to required dia by direct or rotray drilling mud circulation method usingrotray rig, including cost og bendinite mud for drilling at the site site shown by the TWAD board officers including construction of mud pit WD-W0783/ P-198 135 Reaming from 200mm dia pilot bore in to 400mm dia bore as directed by TWAD Board officers. WD-W0805/ P-199 136 Labour charges for inserting ofPVC casing pipe in the drilled hole( With slots and without slots) includingjointing the couplers with cement paste and packing the annular space with pebbles of approved quality. As approved by the Executive Engineer. WD-W0830/ P-201 137 Charges for developing the Bore well with compressor of 600 cfm capacity(Minimum8 hours) including trasportation ,Labour,Fuel ectfor compressor as directed by the TWAD Board officers. WD-W0833/ P-201 138 Supply and delivery of unplasticisedPlain casing pipe of the following diameters in 3m lengtheach as per ISI 12818/1982 to suit deep borefrom 80m to 250m depth(CM)for delivery at site including loading and unloading,frieght,transit insurance and inclusive of all taxes ect.complete. 139 200mm dia PVC casing pipe (CS)WD-M0030/ P-06 140 200mm Dia PVC clatted pipeWD-M0032/ P-06 141 200mm PVC End capWD-M0030/ P-06 142 MSTop End cap WD-M0738/ P-195 143 Charges for Geophysical charges 144 Supply and delivery ofOpen well Horizontaltype Submersiblepump set conforming to IS 14220 /94capable of discharging the following duties due to all causes . The pump shall be with stainless steel shaft and dynamically balanced bronze mixed type impeller and brass screws with ISI mark,. The pump suitable for installation in sump with 1.1KV.grade 3 coresuitable copper flat submersible cable to a length of 15metres with necessary cable joints.The non-return valve located at the top of the pump in the discharge outletconnection is to be designed with minimum friction .The pump should be directly coupled to 2880 rpm, 3 phase, 50 Hz, 415V+6% & 415V-15% squirrel cage induction motor suitable for ATS starting and for continuous operation The pump set should be provided with 5m length of suitable size PVC insulated copper flat cable for connecting the pump set, starter & Isolator. including cost ofitem 1.B50 lpm x 50m HeadWD-M1614/ P-103 145 Supply, delivery of fully auto transformer starter with single phase preventor with Ammeter etc., complete50 lpm x 50m HeadStarter WD-M1909/ P-119 146 Supply, delivery of 1.1 KV grade, 3 core PVC insulated PVC sheathed, Submersible copper cablewith ISI marking conforming to IS 694/1900 of reputed make. 2.5 sqmm copper cable WD-M1974/ P-119 147 Supply and delivery of GI pipesand GIspecials for pumpset erection work. 148 100mm GI pipeWD-M0492/ P-27 149 100mm GI Elbow WD-M0594/ P-32 150 100mm CI Foot valveWD-M0065/ P-223 151 100mm CI Sluice valve WD-M1072/ P-57 152 100mm Heavy longCoupling WD-M1974/ P-32 153 100mm GI Flange set WD-M1974/ P-32 154 110mm PVC threaded couplerWD-M0058/ P-08 155 M.S. Bolt & Nut WD-M0589/ P-31 156 Rubber insertion sheetWD-M0591/ P-31 157 M.S. Clamp setWD-M0617/ P-32 158 Labour charges for erection of2.0 HP submersible pumpset in the borewell 159 Errection of 2.0 HP submersible WD-W0855/ P-203 160 Supplying and erecting in position of following liters capacity Industrial Model Reverse Osmosis Water-cum- Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. 161 (a) MS Skid - 1 No.(b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set(c) Feed Pump 0.50 HP – 1 No.(d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No.(e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos.(f) Flow Meter - 1 No. 20” Filter with Housing - 1 No. Low Pressure Switch - 1 No.,Level Switch - 1 No. &Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install theSystem in position and intact. (M-0723) - 500 Ltrs 162 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 163 Supplying and fixing in position CI manhole covers with CI frames (Heavy duty) of size 60cm x 60cm of best approved quality as per standard specification etc., complete compying with standard specifications.
Contract Date: Ref. Documents Contract Value : Ref. Document
Trust & NGO No of Bidders 2
34.
Housing Urban and Rular Development #10213638 Price Bid
Providing additional amenities such as Approach road, Compound wall, Entrance Arch, and Bio Medical Waste room to the newly constructed Building for 100 Bedded Critical Care Block in Government Hospital at Sholinganallurin Chennai District. Earth Work Open Excavation By Manual Meansin All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Excavated Earth With A Lead Of 10 Mts. Within The Compound In Places Shown By The Departmental Officers And Clearing And Levelling The Site, Etc., Complete Complying With Standard Specification And As Directedbythedepartmental Officers. , Earth Work Excavation For Foundationby Manual Means For Isolated, Combined And Other Type Foundationsin All Soils And Sub-Soils And To Full Depth As May Be Directed Except In Rock Requiring Blasting Inclusive Of Shoring Shuttering, Bailing Out Water Wherever Necessary And Depositing The Surplus Earth Within The Compound In Places Shown By Thedepartmental Officers With An Initial Lead Of 10 Mts And Initial Lift Of 2.00Mts. And Clearing And Levelling The Site, Etc., Complete Complying With Standard Specification And As Directedbythedepartmental Officers. , Installation Of Vertical Bored Cast In Situ Rcc Pilesin All Types Of Soils, Using Ready Mix Concrete Of M25 Grade, Withcement, Fine Aggregate, 20Mm And Down Graded Hbgs Jelly Coarse Aggregate. The Rate Includes Cost Of Reinforcing Steel, Binding Wire, Fabrication, Welding Charges, Placing Of Reinforcement Cage In Bore Hole In Correct Position, Cost Of Boring To The Required Depth With Bentonite Solution With Temprory Casing Of Required Length, Conveyance Of Rmc To Site And Pouring Concrete Using Tremine Pipes, Conveyance Of All Materials To The Site Including All Tools And Plants, Shifting The Plants And Equipments From One Point To Another, Excavation Of Mud Pits For Circulation Of Bentonite Solution, Closing The Mud Pits To Original Level And Mud Removal With Initial Lead And Lift But Including Dismandeling The Concrete Above The Cut Off Level Etc Complete As Directed By The Departmental Officers Including Socketing. The Reinforcement Cage Should Be Welded Properly For Lifting. The Concrete Cubes To Be Tested As Per Is 456-2000. Acceptance Criteria By Clause 16.1. Frequency Of Testing Should Be As Per Clause 15.2.2. The Length Of Pile For Payment Shall Be Measured Up To Natural Ground Level. The Work Should Be Carried Out As Per Is 2911. Pile Depth Should Be Decided By The Departmental Office At Site. , 300 Mm Dia Pile Having Longitudinal Main Reinforcement Of 6 Nos 12#With Helical Reinforcement At 8 # @ 150Mm C/C With Inner Rings Of 12 # @ 1000Mm C/C With Liftinghook Of12 # At Required Length. , Supplying And Filling In Foundation And Basement, Etc With Crushed Stone Sand (M-Sand) In Layers Of Not More Than 15 Cm Thick Well Watered, Rammed And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Filling In Foundation, Basement, Etc With Quarry Rubbish In Layers Of Not More Than 15 Cm Thick Well Watered, Rammed And Consolidated Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers , Supplying And Filling Basement With Conveyed Earthof Earth With A Lead Of 5 Km From The Filling Should Be Made In Layers Of 15 Cm Thick Well Compacted.The Process Will Be Repeated For Another Layer Or Part There Of At The Specified Intervals As Per Specification And As Directed By The Departmental Officers Etc.,Complete. , Providing Pre Constructional Anti-Termite Treatment For The Construction Of Building Including Cost Of Chemicals Labour As Per Standard Specification. Labour For Preparing The Area For Treatment By Spreading Chemicals And Other Incidental Charges Complete. The Rate Shall Be Inclusive Of Giving Anti Termite Treatment To The Building For The Following Four Stages Including Breaking The Termite Moulds Making Holes With Crow Bars At An Interval Of 12 To A Depth Of 8 In The Periphery Of The Building Including Flooring Area And Pouring Chemicals Etc., Complete As Per Isi 6313/1981. , Cement Concrete 1:5:10 (One Cement, Five Sand And Ten Hard Broken Stone Jelly) Using 40 Mm Gauge Hard Broken Granite Stone Jelly For Foundationincluding Dewatering Wherever Necessary And Laid In Layers Of Not More Than 15 Cm Thick Well Rammed, Consolidated And Curing Etc. Complete Complying With Standard Specification , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces For Reinforced Cement Concrete Works Such As Column Footings, Column Pedestals, Plinth Beams, Grade Beams, Staircase Steps, Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Of Size 90Cm X 60Cm And 10 Bg Stiffened With Welded Mild Steel Angles Of Size 25Mm X 25Mm X 3 Mm For Boarding, Laid Over Silver Oakjoists Of Size 10Cm X 6.5Cm Spaced At About 75Cm Centre To Centre Or At Suitable Intervals Etc. Complete In All Floors Complying With Standard Specifcation. (Payment For Centering Shall Be Given After The Concrete Is Laid) , Supplying And Erecting Centering For Plane Surfaces Such As Rcc Floor/Roof Beam, Lintels, Cantilever Beams, Bed Blocks Etc.. With Necessary Supports And Strutting Upto 3.60M Height In All Floors With All Cross Bracings Using Ms Sheets Made Of 10 Gauge Thick Welded With Ms Angle Of Size 25Mm X 25Mm X 3Mm For Boarding Laid Over Steel Adjustable Span Of Size 2M X 2M(Expandable Upto 3.60M) And Silver Oak Joists Of Size 10 X 5 Cm Spaced At 50Cm To 60Cm C/C And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick) Spaced At Not More Than 50 To 60Cm C/C , Etc Complete Complying With Standard Specifications. Steel Adjustable Span And Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Centering For Plane Surfaces Such As Rcc Floor Slab, Roof Slab, Loft, Landing Slabs, Etc With Necessary Supports And Strutting Upto 3.60M Height In All Floors With All Cross Bracings Using Ms Sheets Made Of 10 Gauge Thick Welded With Ms Angle Of Size 25Mm X 25Mm X 3Mm For Boarding Laid Over Steel Adjustable Span Of Size 2M X 2M (Expandable Upto 3.60M) And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick) , Etc Complete Complying With Standard Specifications. Steel Adjustable Span And Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers.(Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Steel Centering Including Necessary Supportsfor Plane Surfaces Such Asrectangular Or Square Rcc Columns Etc. Which Require Only Nominal Strutting Using Mild Steel Sheets Made Of 10 Gauge Thick Welded With Ms Angle Size 40Mm X 40Mm X 5 Mm And Supported By Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M) Made With Outer Steel Pipe With Dia 50Mm (3.60Mm Thick) And Inner Steel Pipe With Dia 40Mm (2.90Mm Thick).Etc..Complete In All Floors Complying With Standard Specifcation. Steel Adjustable Telescopic Props Shall Be Provided As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid). , Supplying And Erecting Steel Centering Including Necessary Supports For Plane Surfaces For Reinforced Cement Concrete Works Such As Vertical Slab, Side Slabs Of Boxing, Vertical Drops, Facia, Vertical Wall, Etc. Using Mild Steel Sheets Of Size 1200Cm X 60Cm And 10 Bg Stiffened With Welded Mild Steel Angles Of Size 40Mm X 40Mm X 5 Mm For Boarding, Laid With Silver Oakjoists Of Size 10Cm X 5Cm& 7.5Cm X 5Cm As Support Runner, Top Horizontal Stiffener Spaced At About 60Cm To 90Cm Centre To Centreor At Suitable Intervals. Ms Channel Section (Ismc 100) Shall Be Provided As A Vertical Support @1.20M C/C And With Lateral Support Of Steel Adjustable Telescopic Props Of Size 2M X 2M (Expandable Upto 3.60M)& Steel Pipes Of 20Mm Dia @ Required Level/Spacing Etc. Complete Complying With Standard Specifcation And As Directed By The Departmental Officers. (Payment For Centering Shall Be Given After The Concrete Is Laid) , Providing And Laying In Position, Standardised Concrete Mix M-20 Grade In Accordance With Is 456 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cement Content Of 325 Kg/M3 And Maximum Water Cement Ratio Of 0.55, Including Admixture (Plasticiser / Super Plasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Foundation Basement , Ground Floor , Providing And Laying In Position, Standardised Concrete Mix M-25 Grade In Accordance With Is:456-2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cementcontent Of 400 Kg/M3 And Maximum Water Cement Ratio Of 0.45, Including Admixture (Plasticiser / Superplasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5.0 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Foundation Basement , Ground Floor , Providing And Laying In Position, Standardised Concrete Mix M-30 Grade In Accordance With Is:456-2000 Using 20Mm And Down Graded Hard Broken Granite Stone Jelly For All Rcc Items Of Works With Minimum Cementcontent Of 400 Kg/M3 And Maximum Water Cement Ratio Of 0.45, Including Admixture (Plasticiser / Superplasticiser) In Recommended Proportions As Per Is:9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability With About (5.0 Cu.M.) 7730 Kg. Of 20Mm Machine Crushed Stone Jelly And With About (3.3 Cu.M.) 5156 Kg. Of 10-12Mm Machine Crushed Stone Jelly And With About (4.79 Cu.M) 7670 Kg. Of Crushed Stone Sand, But Excluding Cost Of Reinforcement Grill And Fabricating Charges, Centering And Shuttering And Also Including Laying, Vibrating With Mechanical Vibrators, Finishing, Curing, Etc. And Providing Fixtures Like Fan Clamps In The Rcc Floor/ Roof Slabs Wherever Necessary Without Claiming Extra, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. The Coarse And Fine Aggregates To Be Used Should Comply With The Requirements Of Is Standards. (No Separate Payment Will Be Made By The Department For The Excess Usage Of Materials). , Foundation Basement , Supplying, Fabricating And Placing In Position Mild Steel / Ribbed Tor Steel Grills For All Rcc Works As Per Design Given Including Cost Of Steel And G.I. Binding Wire In All Floors Etc. Complete Complying With Standard Specification.(Contractor Has To Make His Own Arrangements For The Supply Of Steel And Binding Wire) , Brick Work In Cement Mortar 1:5 (One Cement : Six Sand) Using Best Quality Fly Ash Bricks 230 X 110 X 70Mm For Superstructure Including Curing, Etc., Complete Complying With Standard Specifiction.Foundation & Basement , Brick Work In Following Cement Mortar 1:6 Using Fly Ash Bricks Of 230 X 110 X 70Mm Size Conforming To Is:12894-1989 Class Designation Not Less 50 Kg./ Sq.Cm. Average Compressive Strength In Cement Mortar 1:6 For Load Bearing Structures For Foundation And Basement And For Superstructure Including Curing, Etc., Complete Complying With Standard Specifiction. , Ground Floor , First Floor , Paving The Floor With Best Quality Vertified Tiles Of Size 600 X 600 X 8Mmof Approved Colour, Shade And Quality Laid In Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) 20Mm Thick In All Floors And The Top Pointed With The White Cement Mixed Same Colour Pigments Etc., Complete Complying With Standard Specification.(The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works) , Dadooing With Granite Tiles Of Synthetic Grey, Paradise, Andsimilar Varieties Of Suitable Sizes In Cement Mortar 1:2 (One Cement And Two Crushed Stone Sand) 10Mm Thick And Pointing The Joints With White Cement Mixed With Colouring Pigments At The Rate Of 0.40 Kg. / Sq.M. Neatly In All Floors, Curing, Etc., Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Windows Of Casement Type (Open) From The Profile The Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Are Reinforcement With Gi/1Mm 125Gsm And 100% Corrosion Free, The Profiles Are Multi Chambered Sections With Wall Thick Of 2Mm. The Epdm Rubber (Black Colour) Covered With Over All The Edges Of Frame And Shutter The Shutter Will Be Provided With Espag Multi Power Point Locks And Also It Operates As Handle.The Corners And Joints Should Be Welded And Cleaned.Radiations Free Pin Headed Plain Or Brown Colour Glass 4Mm Thick Should Be Provided To The Shutter And It Should Not Allow Leakage Of Water Even At Most Ranging Storms And Should Have Key Lockable Action, Security Protective Hinges, Strong Lockingsystems And As Per Size For Arresting Noise And Energy Loss.The Connecting Mechanism Between Sash And Outer Frame That Enables Opening Of The Window.The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames.The Window Should Be Got Approved From The Executive Engineer Before Use On Work , Supplying And Fixing Upvc (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators Of From The Profilethe Size Of Outer Frame 60Mm X 58Mm And Shutter Profile Size Of 60 X 78Mm Both Profiles Arereinforcedwith Gi/1Mm 125Gsm And 100% Corrosion Free, The Profile Are Multi Chambered Sections With Wall Thick Of2mm.The Epdm Rubber (Black Colour) Covered With All Over The Edges Of Frame And Shutter.The Corners And Joints Should Be Welded And Cleaned.Radiations Pin Headed Glass 4Mm Thick Should Be Provided In The Louvers.The Window Should Be Fixed To The Wall With 100% Packing With Screws And Silicon Packing All Round The Frames. The Ventilator Should Be Got Approved From The Executive Engineer Before Use On Work , Supplying And Fixing M.S. Grills For Doors, Windows And Ventilators Of Approved Design And As Directed By The Departmental Officers Including Cost Of Ms Grills Labour Charges And Cost Of One Of Red Oxide Primer Coat Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Paving The Top Of Roof With Solar Refelective Ceramic Tiles Of Size 305 X 305 X 7Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three Crushed Stone Sand) 12Mm Thick And Pointed With Tile Grout (Nitotile Grout Or Equivalent) And Cement In The Ratio Of 1:3 For Joint, Curing Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.(The Make And Brand Of The Tiles Should Be Got Approved By The Executive Engineer Before Use On Works) , Supplying And Fixing In Position Best Approved Of Bis Quality Pvc Rain Water Down Fall Pipes Having A Pressure Of 6 Kg. / Sq.Cm Including Cost Of Necessry Pvc Shoe, Pvc Bend, Cost Iron Gratings Of Required Diameter And Special Clamps, Brass Screws, Nails, Etc., And Fixing Of Cast Iron Gratings At Junction Of Parapet And The Rcc Roof Slab Including Finishing Neatly Etc., Complete. The Rate Shall Be Inclusive Of Cost Of Removable Cast Iron Grating. The Pvc Pipe Shall Be Fixed In Wall With Special Type Of U Clamp At The Centre Of The Pipe Line In Addition To Those For More Than 3.0 Metre Pipe Length, Etc., Complete Complying With Standard Specification. , 160Mm Dia , Plain Cement Concrete 1:2:4 (One Cement, Two Crushed Stone Sand And Four Hard Broken Stone Jelly) Using 6Mm To 12 Mm Jelly For Wearing Coat Includinglaying, Compacting, Finishing And Curing, Etc., Complete As Per Standard Specificatins And As Directed By The Departmental Officers.- Mixing By Manual Means , Plastering With Cement Mortar 1:5 (One Cement And Five Plastering Sand), 12Mm Thick In All Floors Including Mortar Plasticizer At 200Ml Per 50Kg Of Cement Used, Curing Etc. Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Plastering With Cement Mortar 1:3 (One Cement And Three Plastering Sand) 12Mm Thick Mixed With Water Proofing Compound Conforming To Bis At 2% By Weight Of Cement Used Including Finsihing, Curing, Etc., Complete In All Floors Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Applyingof Two Coats Of Putty3mm Thick Over The Exposed Rcc Surface Of Ceiling Including Finishing The Joints Smoothy With Grinding Machine And The Surface Shall Be Througly Cleaned Out Of Dust And Scrubbing The Surface Shall Than Be Allowed To Dry For Atleast 48 Hours. It Shall Be Than Sand Papered (Waterpoof Abrasive Sheet) To Give A Smooth And Even Surface. Any Uneveness Shall Be Made Good By Applying 1 St Coat Of Putty Mixed Withwater On The Entire Surface Including Filling Up The Undulations And Applying2 Nd Coat Of Putty After 6 Hours Of 1 St Coat Of Putty And Then Sand Papering ( Waterpoof Abrasive Sheet) The Same After Its Dry And Finishing Thesurface Smoothy Etc.,Complete Complying With Standard Specifiction And As Directed By The Departmental Officers.(The Rate Inclusive Of Hire Chargesfor Grinding Machine With Wheel,Cost Of Sand Paper(Waterpoof Abrasive Sheet) Cost Of Putty Blade,Labour Charges For Grinding The Joints And Sand Papering,Two Coats Putty,Scrapping The Putty Area To Level The Surface Smooth Etc., Complete). The Putty Should Be Got Approved By The Execuctive Engineer Before Use On Work. , Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Plastic Interior Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris Putty, Wherever Required Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Painting Two Coats Of Newly Plastered Wall Surface With Ready Mixed Plastic Exterior Emulsion Paint Of First Class Quality And Of Approved Colour Over A Priming Coat Including Thorough Scrapping, Clean Removal Of Dirt, And Including Necessary Plaster Of Paris Putty, Wherever Required Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Textured Wall Painting With Exterior Weather Proof Emulsion Paint (2 Coats) Of Approved Quality And Colour Over A Priming Coat Including Through Scrapping, Clean Removal Of Dirt Etc., Complete And Including Necessary Plaster Of Paris, Putty Whereas Required As Directed By The Departmental Officers. , Supplying , Fixing And Roofing With Colour Galvalume Sheet Of 0.47Mm Thickwith All Necessary Accessories Such As J/V Bolt And Nuts Of Suitable Length With Suitable Bitumen Washers Complete Complying With Standard Specification And As Directed By The Departmental Officers. , Supplying And Fixing Zinc Sheet Roof Usingsquare Tube And Tied With Welding The Rate Including The Cost Of Materials,Scafolding Charges,One Coat Of Primer And Two Coat Synthetic Enamel Anticorrosivepaint Etc.,Complete And Complying With Standard Specification. , 75X75x4mm Square Tube , 50X50x4mm Square Tube , 40X40x3.20Mm Square Tube , Painting New Iron Works Such As Steel Doors, Windows, Ventilators, Window Bars, Balustrades Etc., With Two Coats Of Best Approved First Quality And Colour Of Synthetic Enamel Paint Over One Coat Of Priming Coat Using Zinc Chromite Primer In All Floors Including Cost Of Priming Coat Etc., Complete Complying With Standard Specification. (The Make, Quality And Colour Of Paint Should Be Got Approved By The Executive Engineer Before Use On Works.) , Casting, Supplying And Fixing Of Die Cast Brass Letterswith Thickness Of 20Mm Hollow Type In English / Tamilof Following Sizes. The Die Cast Letters Should Be Finished Neatly And Provided With Powder Coating Finish Of Approved Colour Etc., As Directed By The Departmental Officers. The Rate Includes The Cost Of All Materials, Casting, Transportation And Fixing In Position Etc.,Complete As Per The Standard Specification. , Tamil Brass Letters , Emblem (15”) , Paving The Floor With Pre-Polished Concrete Anti-Skid Tiles (Required Shape And Design) Of 20Mm Thick Of Approved Quality And Colour Laid In Cement Mortar 1:3 (One Cement And Three Sand) 20Mm Thick And Pointed With White Cement Mixed With Colouring Pigment At The Rate Of 0.40 Kg. / Sq.M., Curing, Etc., Complete Complying With Standard Specification And As Directed By The Departmental Officers.(The Make And Brand Of The Tiles Should Be Got Approved By Executive Engineer Before Use On Works). , Manufacturing, Supplying And Fixing Of Stainless Steel Hand Rails For Staircase Using 50Mm Dia 304L Grade Stainless Steel Pipe Of 1.60Mm Thick At Required Locations To A Hseventh Of 900Mm From Finished Floor Level Welded To 38Mm Dia Stainless Steel Pipe Post Of 1.00Mm Thick As Vertical At 900Mm Centre With 2 Nos. Of 25Mm Dia Intermediate Horizontal Stainless Steel Pipe Of 1.60Mm Thick In Between.The Vertical Pipe Has To Be Welded To The 100 X 100 X 6Mm Ms Base Plate Encased In The Base Concrete.The Rate Is Inclusive Of The Charges For Cutting, Bending, Welding, Grinding, Polishing, Conveyance, Electrical Charges, Etc. Complete , Supplying And Erecting Pull And Push Type Rolling Shutter With Isi Make Of Approved Size And Section Using 18 Gi Sheet.The Shutter Shall Be Painted With One Coat Of Red Oxide Primer And The Rate Is Inclusive Of Hood Covers, Transportation Charges Et , Supplying And Fixing In Position Salem Stainless Steel Door Frames 105 X 60Mm With 35Mm Single Rebate With 1.60Mm Thick Sheet Frames Including Bottom Tie, Hod Fast And Provision To Fix Aldrops, Tower Bolt, Hinges And Lock Strike Plates Confirming To Is 4231 - 1976 Including Filling The Rear Hollow Portion With Pcc 1:2:4Using One Cement, Three Sand And Six Aggregate Using 12Mm Gauge Hard Broken Granite Stone Jelly Including Cost Of Dismantling The Masonry And Concrete Wherever Necessary And Redoing The Same To To The Original Condition After Fixing Including The Scafolding Charges And Labour Charges For Fixing Furniture Fittings Etc., But Including Cost Of Furniture Fitting With Standard Specification. , Supplying And Fixing Solid Core Particle Board Flush Shutter Of Nominal Thick Of 35 Mm With Necessary T.W. Internal Lipping Conforming To Is 2302 With Teak Ply On One Side And Commercial Ply On Other Side With Teak Wook Lipping Alround35 Mm Thick Including Supplying And Fixing Cost Of Wind Appliances And Furniture Fittings Such As 1No .200X12mm Aluminium Tower Bolt 2Nos. 150X12mm Aluminium Tower Bolts 1No. 250X16mm Aluminium Aldrops, 3 Nos. 200Mm ‘D’ Type Aluminium Door Handle And Door Stopper With Bush Etc., Complete As Directed By The Departmental Officers. , Double Leaf , Supplying And Fixing 300Mm Dia Rcc Hume Pipe Including Labour Charges Etc., Complete , Provinding Laying For Expansion Joint For Road Cutting Every 3 M Interval With Using Bitumen Etc., Complete , Vaccum Dewatering For Approach Road Flooring Etc., , Providing Expansion Joint Of 12.5Mm Wide In Between Rcc Twin Columns From Top Of Pedastal To Full Height Including Filling The Inner Space With Suitable Non-Absorbent, Flexible And Well Compressible Filler Materials Of Approved Quality And Brand; Finishing The Sides Of Rcc Columns With Polysulphide Sealents For A Depth Of 7.5Mm On Either Side Covering The Inner Space Filled With Filler Materials As Above Etc., Complete Complying With Standard Specifications And As Directed By The Departmental Officers. , Providing And Laying Of Granular Sub-Base By Providing Close Graded Material, Mixing In A Mechanical Mix Plant At Omc, Carriage Of Mixed Material To Work Site, Spreading In Uniform Layers With Motor Grader On Prepared Surface And Compacting With Vibratory Power Roller To Achieve The Desired Density, Complete As Per Clause 401 , Providing And Laying, Spreading And Compacting Graded Stone Aggregates To Wet Mix Macadam 250Mm Thick Specification Including Premixing The Materials With Water At Omc In Mechnanical Mix Plant Carriage Of Mixed Material By Tipper To Site Laying In Uniform Layers With Pavers In Sub Base/Base Course On Well Prepared Surface And Compacting With Vibratory Roller To Acheive The Desired Density Including Cost Of Material, Labour Charges, Rentals For Machinery, Fuel And All Other Incidental Charges Etc., Complete As Per Clause 406 Of Morth Rev-5 , Gst At 18%
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
35.
Drinking Water Supply and Sanitation #10209924 Price Bid
Providing, Installation, Testing And Commissioning Of Pumping Machinery Along With Allied Electro-Mech Equipment At Filtration Plant Seri Sayal Base.= 1 Providing And Installation Of Monosub Pump Set 5000 Gph X 40Mh Coupled With Suitable Motor. The Pumping Machinery Should Confirm To Relevant Iso With All Latest Amendments. The Equipment Shall Also Be Accompanied With Test Certificates And Performance Curves. Installation Of Monosub 5000Gph X 30Mh Along With Allied Electromechanical Equipment By Way Of Fabrication Of 80Mm Dia Gi Column Pipe 10Ft Long Welded With Ms Flanges-80Mm Dia At Both Ends-02Nos, For Making Delivery Of The Pump. Fabrication Of Gi Pipe Nipple With Threads At One End & Ms Flange At Other End & Fastening The Threaded End Of Nipple With The Delivery Of Pump.Fabrication Of Ms Clamps 80Mm Dia. - 02 Nos. Each For Holding Monosub Pump & Column Pipes. Fabrication / Fitting Of Bed Plate For Resting Of Clamps For Holding Monosub Pump & Nipples. Coupling Of Pump Motor With The Help Of Coupling Pulley. Providing / Fitting Automatic Control Panel Of Suitable Capacity And 4Mm Square Submersible Cable -50 Mtr ( Approx ) For Making Of Connection From Submersible Control Panel To Motor With Proper Thimbling And Insulation. Providing / Fitting Of Chain Pulley Block Of Capacity -01Ton Heavy Duty Of Isi Make. Lowering Of Monosub Along With Gi Pipe Nipples Into The Well With The Help Of Chain Pulley Block, Ropes & Skilled / Unskilled Labours. Providing / Fitting Of Ms Bends 80Mm Dia. With Ms Flanges. Providing / Fitting Of 80Mm Dia Check Valve -01No With Ms Flanges, Nut / Bolts & Washers, And Interconnecting With The Raising Main With All Allied Welding Work. The Job Also Includes Providing / Erection Of Steel Tubular Pole Of 8Mtr Long – 03No For Extension Of Lt Network From Pump Room To Percolation Well ( Intake ) . Providing / Stringing Of Conductor Wire All In Tpn - 1.0Km Approx. Providing / Fitting Of U-Clamps, Shackle, Pin Insulator, Nut Bolts And Allied Material Required For Completion Of Work At Site. Complete Job Includes Cost Material Such As Pumping Machinery, Labour Charges, Carriage Charges And Welding Charges Etc Required At Site Of Work. 2 Providing, Installation Of Horizontal Centrifugal Pump Set 5000 Gph X 250Mh Coupled With Suitable Motor At Filtration Plant Seri Sayal. The Pumping Machinery Should Confirm Relevant Iso With All Latest Amendments. Installation By Way Of Laying Of Foundation Block Of Size 2Mtr X 1 Mtr X 1Mtr Depth Inside The Pump Room By Way Of Excavation Of Floor And Disposal Of The Excavated Earth By Using Manual Labour Outside The Premises. Cleaning And Levelling Of Excavated Trench. Laying Of Foundation Block Of Rcc For Installation Of Hcp 5000 Gph X 250 Mh. The Job Includes Fabrication, Welding And Laying Of Steel Mesh Made From 12Mm Tor Steel Placed Horizontally, Vertically And Diagonally At Equal Distance Including Form Work. Laying Of Foundation Block Of Rcc In The Ratio 1:2:4 ( Cement, Sand And Bajri ) And Grouting Of Fabricated Foundation Bolts. The Entire Block To Be Laid In Such A Way That It Can Dump All Types Of Mechanical Vibration Created By Dynamic Load Of The Pump. Placing Of Base Frame And Levelling. Tightening Of Base Frame By Fastening Of 6 No. Foundation Bolts. Complete Job Includes Cost Of All Types Of Material Such As Cement, Sand, Bajri, Tor Steel, Foundation Bolts, Nuts, Washers, Bolts, Carriage Of Material To Site Of Work On H / L, Hire Charges Of Tools And Tackles, Labour Charges Of Skilled And Semi-Skilled Workers. Placing The Hc Pump Set And Motor On The Base Plate Tightening Of Foundation Bolts Of Pump And Motor Set Fixing Of Coupling Pulley On Drive End Side Of Pump And Motor Shaft With The Help Of Cotters And Coupling Bolts. Proper Leveling Of Pump Motor Set On The Base Frame By Way Of Providing Steel Shims And Checking The Alignment Of Pump Motor Set. Fabrication, Fitting And Laying Of 80 Mm Dia Suction Line From Service Reservoir Upto The Suction Of Hc Pump Set As Per Site Requirement By Way Of Cutting, Fitting Of 80 Mm Dia Flanges And Welding By Using Good Quality Electrodes So As To Get Leak Proof Joints. Fitting Of 80 Mm Diasluice Valves With Flanges, Bends Properly Welded As Per Site Requirement Which Is Required For Stopping The Flow Of Water In Suction Line For Maintenance Of Pump Set. Providing And Fixing Reducer Nipple With Flanges On Both Sides With Proper Bend To Be Fitted On The Suction Side Of The Hc Pump Sets. Fabrication, Fitting And Laying Of 80 Mm Dia Delivery Line For Hc Pump Sets. Fabrication And Fitting Of Expander Nipple On The Delivery Side Of Pump Set With Flanges On Both Sides To Be Connected With Delivery Side Of The Pump Set With Matching Holes On One Side And 80 Mm Dia Delivery Line On The Other Side. Providing And Welding 80Mm Dia Half Bends With Flanges On Both Sides As Per Site Requirement. Fitting Of 80 Mm Dia Sluice Valves And Reflux Valves-01 No Each With Nuts, Bolts And Gaskets With Proper Flanges On Both Sides. Extension Of The Delivery Line From Reflux Valve Upto The Common Manifold By Way Of Providing Bends Nipples Etc. As Per Site Condition. The Complete Welding Work On The Delivery Line Shall Be Done By Using Superior Quality Welding Electrodes So As To Avoid Any Air Gap And To Ensure Leak Proof Joints. The Delivery Lines Of Pump Set Shall Be Connected / Joined / Welded With The Rising Line. Complete Job Including Cost Of Material, Hire Charges Of Tools And Tackles. 3 Fabrication And Fitting / Grouting Of Angle Iron Panel Board Fitted With 12Mm Thick Water Proof Ply With Good Quality Mica. Providing / Fitting Of 200Amp 415V Hrc Type Main Switch ( H / Duty ) -01 No, Providing / Fitting Of 185Mm Square Aluminium Cable -20 Mtr-3.5 Core For Making Of Connection From Lt Fuse System To Main Switch With Proper Thimbling And Insulation. Providing / Fitting Of 200Amp Busbar On The Panel Board. Providing / Fitting Of Suitable Capacity Starter On The Panel Board. Providing / Fitting Of Suitable Capacity Of Copper Cable For Making Connection From Lt Control Panel To The Motors.Checking Continuity Of Whole Electric Circuit. 4 Fabrication / Manufacturing Of 100Kva Voltage Stabilizer At Oil Cooled Unbalance Type 415Volt At Base And Stage Ist Of Wss Seri Sayal, Complete With Transformer Oil In Copper Windings Capable Of Operating On Unbalanced Voltage. Installation, Testing & Commissioning Of 100Kva Voltage Stabilizers By Way Of Carriage / Shifting Of Stabilizer To Site Of Work On Mt And Hl. P / F Of Aluminium Cable 185Mm Sq Unarmoured-20Mtr Appox Of Standard Isi Make ( As Per Site Condition ) For Making Connectionsfrommainswitchto Voltagestabilizer For All The Threephasesin Threeleadswithneutral & Then From Stabilizer To Buss Bar Fuse Systemwith Properthimblingdulycrimpled By Usingcrimpling Tool& Proper Insulation. Filling Of Transformer Oil Up To Required Level After Heat Treatment / Dehydration To Make It Moisture Free. Job Includes Cost Of Material And Fitting Charges. Specification As Below Capacity: 100Kvaphase :03Make Confirming To Relevant Iso With All Latest Amendmentsinput Voltage : ( 160-380 ) Voltoutput Voltage:415 Volts+ / - 1% Type :Manually Operatedcorrection Rate :12 To 35 V / Secregulation:+ / - 1%Frequency : 48 To52 Hzcooling Method :Oil Cooledefficiency : 95%High & Low Cut Off : Installed With Standard Capacity By Pass Change Over Switch :Yesmccb:Heavy Dutysingle Phase Preventer :Yesmaterial Of Construction :The Core Should Be First Quality ( Crgo ) Silico Steel Core, Conducting Conductor Should Be Off 99.95% Of Electrolytic Copper Ms Steel Thickness Of Container 14 / 16 Swg. Transformer Oil To Be Used Shall Be Of Best Quality Conforming Of Is 335 With Latest Amendments.Voltage Stabilizer Shall Be Mounted On 02 Pairs Of H / D Ms Wheels For Making Shifting / Fixing Easy. Voltmeter / Ampere Meter Good Quality Isi Make Of Required Specification, Toggle Switch 03 No For Input / Output Reading Of Each Face Rotary Switches Of Suitable Amp Range Each Of 08Steps. Painting Shall Be Enameled Steel Grey / Green Colour. 5 Testing And Commissioning Of Hc Pump Motor Set With Stand By And All Other Allied Electro Mechanical Works. Checking Of All Electrical Connections, Tapping And Tightening All Other Connections. Plugging Of Leaking Joints If Any By Way Of Welding, Replacement Of Gaskets And Tightening Of Nuts And Bolts. Checking The Alignment Of Pump And Motor Sets And Testing The Machinery On Full Load. Complete Job
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Jammu And Kashmir View Result →
36.
Power #10207637 Price Bid
Work Contract for Supply and Erection of 1 No Outdoor Bay with 33KV Outdoor VCB at 110KV Vyasarpadi SS for laying of 33kV, 3x400 Sq.mm XLPE UG cable from Vyasarpadi 110kV SS to proposed Electric bus charging station at West Avenue Road, MKB Nagar of CEDC / North in Chennai North Reg- 1 Supply of AB Switch 33KV SS Centre Rotating Type 2 Supply of 22 KV PT Insulator 3 Supply of 11 KV 120 KN Disc Insulator ordy 4 Supply, Transport, Loading and Unloading, galvanizing of RS joist (250X125/200X100) and M.S.Plate(10/12 mm) to the site including cost of material, labour, lead, lift etc., complete as directed by the department engineer at site. 5 Supply, Transport, Loading and Unloading, galvanizing ofMS Channel (125x65/100x50) MS Angle to the site including cost of material, labour, lead, lift etc., complete as directed by the department engineer at site. 6 Supply, Transport, Loading and Unloading of MS Round rod (40mm) to the site including cost of material, labour, lead, lift etc., complete as directed by the department engineer at site. 7 Supply, Transport, Loading and Unloading of MS Flat (65x10 / 50x8) to the site including cost of material, labour, lead, lift etc., complete as directed by the department engineer at site. 8 Labour for erection of Heavy section structure ( Secwtabove14 kg/m) (Under Normal condition) 9 Labour for erection of Light section structure ( Sec. wt below 14 kg/m) (Under LC condition) 10 Erection of Equipments 11 Labour for erectionof 11/ 33KV VCB/SF6CB with own crane arrangement and connecting link rod, SF 6 gas filling and,& other consumables, & as directed by the field Engineer. (Under Normal condition) 12 Labour charges for erection of33 or 22 or 11KV CT(One 1Ph or 3Ph unit)using manual labour or crane by own arrangement (Under Normal condition) 13 Labour charges for erection of CT,PT junction box including fabrication of clamp (Under LC condition) 14 Labour for erection ofAB Switch 33 or 22 or11 KV without earth hand operated (Under LC condition) 15 Labour forerection of LAS including fabrication of base if required 16 station type33or22or11KV 17 Erection of Battery & Panels 18 Labour for Erection of Panel/Battery ChargerSimplex indoor/outdoor 19 Erection of Bus materials 20 Labour for erection ofsingle pole stack upright,under hang or suspension insulator 33 or 22 or 11kV . (Under LC condition) 21 Labour for stringing of Main bus including hoisting of insulators 33 or 22 or 11KV strung bus singlezebra conductor(1 span 3 runs). (Under LC condition) 22 Labour for erection of bus barUsing 50mm without making bends. (Under LC condition) 23 Labour for providing of jumpers and droppers. (Under LC condition) 24 Earthing 25 Labour, Machineries, Consumables for Fabrication ofearth electrode of 6 Mtr required length for Yard 26 Labour, Machineries, Consumablesfor fabricationand erection of earth spike. (Under LC condition) 27 Labour, Machineries, Consumables for erection ofearthmat and earth raiser (Under Normal condition) 28 Providing 140/150 mm dia bore using power rig inculding labour, lead lift etc.In all type of soil and erection ofearth electrode, supply and providing of A grade Bentonite powder with 5% common salt mixed with available site clay soil 5 Kg per metre depth in earth hole as directed by the field Engineer. Machine Bore 29 Supply and providing of 600mm mean dia,300mm height,36mm thick cement collar for identification of earth electrode locationincluding 1 primer and 2 coat of colour wash as directedby fieldengineer. 30 Labour for excavation and refilling oftrench of ave.width of 0.3M and ave.depth of 0.8M for earthmat and and ave.depth of 0.4M for layingof cable below fixed yard level and ofany size as required by field engineer. 31 Control cables 32 Labour for laying of cable in duct / trench including the cost of Alu. tag for identification Upto 8 core 33 Labour for laying of cable in duct / trench including the cost of Alu. tag for identification above 8 core 34 Labour for laying of cable& Clamping in structure 35 Labour for excavation and refilling oftrench of ave.width of 0.3M and ave.depth of 0.4M for layingof cable below fixed yard level and ofany size and filling with sand before and after laying of cable and laying of brick on sand and refilling of trench including cost of sand and brick and other consummables . 36 Supplyandglandingof ISI mark cablegland of suitable size of reputedmake including removing insulation of cable and providing suitableholes as directedby the field engineer. 37 19 mm 38 25mm 39 28mm 40 Supplyandterminationof cable core end including cost ofcable socket (Lugs), ferrules straps etc asper cable scheduleandasdirectedby the fieldengineer. 41 Labour for providing cable core end termination 42 Painting 43 Two coat of aluminum paint to all M.S items including cost of paint brush and consumable 44 Labour charges for painting of Green enamel paint on all kind of structure earthing including removal of dust, rust using wire brush and painting brush etc. 45 Labour charges for removing rust primer coat first and second coat painting both sides and writing details in MS boards and R.S.Joists including cost of enamel paint (dulex, asian berger preferred) and other consumables as directed by the field Engineer. 46 Labour charges for writing details in finished surface boards including cost of enamel paint (dulex, asian berger preferred) and other consumables as directed by the field Engineer. 47 Power connectors 48 Supply of Switch end clamp forzebra 49 Supply of Switch end clamp for 2 Bus 50 Supply of `T`Clamp forzebra tozebra 51 Supply of `T`Clamp for 50mm bus to zebra 52 Supply of 2 Free end 53 Supply of Corona bell for 50 mm bus bar 54 Supply of 4 Bolted tension fitting 55 Miscellaneous 56 supply of rubbermat of size 2000x1000x10mm 57 Manufacturing and supply of bolt of required length out of18,20mm dia GI round including the cost of GI round and 2 Nos. of GI.nets as directed by the field Engineer. Grout bolt & Eye bolt 58 Supply and provision ofM8, M9, M10, M12, and M16 full thread G.I. Bolts and Nuts of various sizes for erection of AB Switches and insulator or any other purpose wherever required and as directed by field Engineer. 59 Fabrication, supplyand fixing of individual equipment board of 750x450mm out of14swg (2mm)Mssheet and25x25x3mm MSangle as per drawing and as directed by the field engineer including costof allmaterials(8kg/boardx10nos) 60 Fabrication and fixing of earth electrode identification board size 300x250mm out of 14SWG(2mm)MS sheet and 12mm dia MS round perdrawing and as directed by the field engineer including cost of all materials(2KG/ boardx25nos) 61 Fabrication supply and fitting of CT/PT junction box out of 14SWG (2.00mm) MS sheet where ever required as directed by field engineer .The box shall have sturdy hinges provision for mounting terminal blocks and locking arrangements including cost of all materials 400WX150DX300H 62 Supply & fixing of nut CBTM 5 or equivalent terminal block in panel /boxas directed by the field engineer 63 Supply & fixing of disconnected type terminal blocksuitable for CT circuits in panel /boxas directed by the field engineer 64 Supply and erection of B class GI pipe for extension of tandem/down pipe forAB switches and for any other work as required and directed by the field engineer including cost of Gi pipe 40mm dia (3.5m*11) 65 Supply and fixingof (Godrej) 6 lever navotal lock with triplicate keys for AB Switches and for any other purpose including the cost of ring and key token as directed byfield Engineer. 66 Labour for loading or unloading or shifting of materials without using Boards crane ( One operation) 67 Non-fragile 68 Fragile 69 Labour for loading or unloading or shifting of33/22/11KV Breakers including panels by own crane arrangement 70 Transportation chargesfortransport of TANGEDCO materials from Tangedco stores to work spot 71 CIVIL WORKS 72 Supply & Labour for providing plinth for 33KV Breakers 73 Supply & Labour for providing plinth for 33KV cable SPT pole and RSJ 74 GST For bidders within Tamil Nadu Note: Builders within Tamil Nadu shall enter values seperately for SGST and CGST and shall enter the value as Zero for IGST 75 SGST 76 CGST 77 GST for bidders out side Tamil NaduNote: Bidders outside Tamil Nadu shall enter value only for IGST and shall enter the value as Zero for SGST and CGST 78 IGST
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
37.
Housing Urban and Rular Development #10204751 Price Bid
Tender For Lake Front Development At Porur Chennai.; 1 CIVIL WORKS 2 Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by thedepartmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification. 3 Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification. 4 Clearing Scrub Jungle, etc., complete complying with standard specification and as directed by the departmental officers. 5 Installation of Vertical Bored cast in situ RCC piles of 300 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 6 Installation of Vertical Bored cast in situ RCC piles of 380 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 7 Installation of Vertical Bored cast in situ RCC piles of 450 mm diameter and M-30 grade of concrete in all types of soils, using Standardised Concrete Mix of following grade, with sulphate resistant Cement or OPC/PPC, etc and Crushed Stone Sand and 20mm and down graded HBGS jelly coarse aggregate. The rate includes cost for placing of reinforcement cage in bore hole in correct position, cost of boring to the required depth with Bentonite solution with temprory casing of required length, conveyance of RMC to site and pouring concrete using Tremine pipes, conveyance of all materials to the site including all tools and plants, shifting the plants and equipments from one point to another, excavtion of mud pits for circulation of Bentonite soultion, closing the mud pits to original level and mud removal with initial lead and lift but including dismantling the concrete above the cut off level etc complete as directed by the departmental officers including socketing. The reinforcement cage should be welded properly for lifting. The concrete cubes to be tested as per IS 456-2000. Acceptance criteria by clause 16.1. Frequency of testing as per 15.2.2. Testing to be conducted at both the ends at site as well as RMC plant. Pile driving depth should be decided by the departmental officers at site. The length of pile for payment shall be measured from top of shoe to the bottom of the pile cap. (Cost of Reinforcement provided for Pile and Welding charges shall be measured and Paid separately) 8 Refilling with excavated earth in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification. 9 Supplying and filling with earth up to 10 Km for foundation and basement, etc., including watering and consolidating, etc., complete complying with standard specifications and as directed by the engineer-in-charge 10 Supplying and filling in foundation, basement, etc with Stone Dust in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 11 Supplying and filling in foundation, basement, etc with Crushed Stone sand filling in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. 12 Plain Cement Concrete 1:4:8 (one part of cement, four part of Crushed Stone Sand (M- Sand) and eight part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 13 Plain Cement Concrete 1:2:4 (one part of cement, two part of Crushed Stone Sand (M- Sand) and four part of coarse aggregates) using 40mm size ISS HBG metal including cost and conveyance of all materials to site and including for the mixing, laying and labour charges and all incidential charges such as water providing etc., complete as per standard specification 14 Construction of Granular sub-base of required compacted thickness by providing laying, spreading and compacting of Close graded Material conforming to Grading V of Table 400-1 of MORTH clause 401,mixing in a Wet Mix Plant of 200 tonne capacity at OMC, carriage of mixed material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory roller 8-10 tonne to achieve the desired density of 98% including protection of edges of GSB layer, cost of all materials, labour, hire charges of machinery, lighting, guarding, barricading, maintenance of diversion road, loading & unloading, all lead and lift etc., to achieve minimum CBR value of 30%(Compacted Thickness) in accordance with MORT&H technical specification clause No. 401 and with all other incidental charges and as per the direction of the Engineer-In-Charge of work. 15 Damp proof course with Cement Mortar 1:4 (One Cement and Four sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification. 16 Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below.Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. 17 Random Rubble masonry in Cement Mortar (1:3) etc., Complete complying with standard specification and as directed by the Departmental Officers 18 Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oakjoists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid). 19 Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid). 20 For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc. 21 For plane surfaces such asrectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc. 22 For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc. 23 Centering for curved surfaces of all RCC items of work 24 Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part there of but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers. 25 Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 26 Foundation and Basement 27 For Ground Floor 28 For First Floor 29 Providing and laying in position, Standardised Concrete Mix M-30 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 400 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers.The coarse and fine aggregates to be used should comply with the requirements of IS Standards.(No separate payment will be made by the Department for the excess usage of materials). 30 Foundation and Basement 31 Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) 32 Brick work in Cement Mortar 1:3 using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9 x 4-3/8 x 2-3/4 for foundation and basement including curing, etc., complete complying with standard specifiction. 33 For foundation & basement 34 In Ground floor 35 In First floor 36 Brick partition walls of 11.50cm thickness using best quality II Class Ground Chamber Burnt Bricks of size 9 x 4-3/8 x 2-3/4 in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately). 37 Ground floor 38 Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. 39 Inner Plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 40 Outer Plastering with Cement Mortar 1:4 (One cement and Four sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. 41 Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers. 42 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush.Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed.Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 43 White washing two coats with freshly burnt white shell lime in all floors including cost of lime, blue powder fevicol type gum, brushes, scaffolding charges, etc., complete complying with standard specification and as directed. 44 Supplying and painting the walls with two coats of wall putty as instructed by the departmental officers including preparation of surface curing, etc., complete in all floors complying with standard specifications and as directed by the departmental officers. (The wall putty shall be got approved by the Executive Engineer before use of work). 45 Painting newly plastered wall surface with two coats of ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. Interior painting 46 Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification. 47 Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 48 Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) 49 Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers. 50 Flooring with first quality design ceramic tiles of all colours of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand)base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) 51 Paving the floor with best quality Double Charged Vetrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification.(The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works). 52 Providing And Fixing Machine Dressed Grey Granite Slab All Sides Machine Cut of Size 0.60 M X 0.60 M Size And 50 mm Thick Granite Slabs For Platform(Pavement) Including Cost And Conveyance ofGranite From Available Source Including Labour Charges For Fixing the Slab In Position To The LineLevel And GradientIncludingPointing With cm.1:3 And All Other Incidental Charges Etc.Complete 53 Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise andsimilar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification. 54 Paving the floor with Cement based Hydraulically pressed Anti skid tiles (pattern design) - 20 mm thick (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works). 55 Dadooing walls with Colour designed digital print ceramic tiles, with borders, with size of 300mm x 450mm x 8mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand)10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. nbatly in all floors, curing, etc,,complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be like Johnson / Kajaria / Somany / Nitco / RAK or Equivalent which has to be got approved by Executive Engineer before use on works). 56 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between.The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete.The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete 57 Nosing the granite slab - single nosing as directed by the engineer-in-charge 58 Grooving the granite slab as directed by the engineer-in-charge 59 Manufacturing, supply & fixing of precast kerb stone of size 400mmx259mmx200mm thick made of M 20 grade of concrete rectangular in shape with one corner chamfered by 100 mm x 100 mm as per approved design i/c cost of all material, labour and curing etc., complete. as per IRC 5758 - 1984. 60 Supplying and laying hydraulic pressed monolithic natural grey colour cement concrete inter locking paver block of 63mm thick, in cement concrete 1:2:4 (one cement, two sand, four aggregate) using difference design and with stand for pressure of 150 - 200 kg/m2 over the existing sand cushion by using earth rambers and also vibratting the concrete blocks often laying using plate vibrators etc, complete as directed by the departmental officers. 61 Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. 62 UPVC Window Specification:Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle.The corners and joints should be welded and cleaned.Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong lockingsystems and as per size for arresting noise and energy loss.The connecting mechanism between sash and outer frame that enables opening of the window.The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames.The window should be got approved from the Executive Engineer before use on work 63 Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm.The profiles should have co-extruded seals. Hardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass through the reinforcement chamber.The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug. 64 ABS DOOR Specification:Providing and fixing of ABS (Acrolynitrile Butadiene Styrene) Door using factory made plain FPVC (Foamed Polyvinyl Chloride) door frame of the size 105 x 40mm with a wall thickness of 10mm made out of extruded rigid FPVC profile mitre joined with 10 Nos. of 50mm long screw.The door frame shall be fixed to the wall by using 80mm long screws through the frame with the help of PVC fasteners to be provided for each vertical member, stiffeners of (‘U’ Channel of size 29 x 9 x 1mm, 150mm long) 3 Nos. at hinge point, frame reinforcement of (‘U’ GI Channel of size 46 x 22 x 0.06mm), bottom tie rod of (‘U’ GI Channel size of 15 x 15 x 1mm), the ABS Shutter of 35mm thick factory made plain pre-laminated.ABS (Acrolynitrile Butadiene Styrene) door shutter moulded in different designs, consisting of all round Frame made out of water proof solid foam PVC bar of size 20x32mm, reinforced by 32 x 32mm - 2 Nos. for vertical made out of LVL (Laminated Veneer Lumber), core material of 32mm thick high density craft paper honey comb board, sandwiched on both sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of ball bearingbutterfly hinges - 3 Nos. for each shutter and ISI make SS round lock complete, including cost of Materials, conveyance and all other incidental charges and labour charges for fixing the Door neatly etc., complete complying with the standard specification. The door shutter and frame should be got approved from the Executive Engineer before use on workPlain Pre-laminated Door 65 Fabrication supply and fixing in position of aluminium natural colour matt finish louvered ventilator in all floors made with extruded aluminium section of following size with necessary accessories such as rubber beading, best quality of handle including supplying and fixing of 4 mm thick plain glass including cost of all materials, labour power consumption required for fabrication drilling holes in RCC column/floor slab/ masonry wall wherever necessary with power drills to the required extent and making good to the original condition after fixing etc., and as directed by the departmental officers etc. complete.The aluminium frames to be anodised under electrically controlled condition in accordance with ISI 1868/ 1962 specification for an average anodic film thickness of not less 15 microns and all the materials should be got approved by the Executive Engineer before use on work. Outer frame alround section of size 62x38x2mm @ 1.174 kg/ m vertical louvered section of size 60x30x4mm @ 1.27 kg/m and aluminium clips of size 19.05x10.27/11.05x1.20mm @ 0.169 kg/m. 66 Supplying, fabricating, erecting structural steel work for roofing welded or bolted type using MS channels, angles, plates and round bars etc. conforming to IS specification including primer coating and enamal painting as per Design given by the departmental officers etc, complete as per standard specification 67 Roofing with best quality prelaminated Polycarbonate Sheet 6mm thick of approved colour design and quality including cost of self tapping screws between washer and cutting the sheet to required slope if found necessary during execution of work, including charges for machine etc., complete, as directed by the engineer-in-charge 68 Supplying and fixing of Exterior WPC louvered panel for cladding and roofing works with material specifications: Material - WPC, Size - 2900 x 200 mm, Design exterior decorative panel, Color - Brown, Usage/Application for all kinds of exterior work, Thickness - 26mm, Core Filling - Fly Ash, Packaging Type - fully packed, etc., complete as directed by the engineer-in-charge 69 Supplying and Fixing ofCNC cut perforated Enclosure for EB transformer and EB pillar Boxes by using CNCMS Sheet (2mm thick), doorhinged with vertical support of80X40 mm TubularPost including horizontal Support and Stiffener (40 x40 x2mm)for MS sheet including Powder coating ofall structural members and labor for fitting , welding andtransportation of thematerial from thefactory to Site as directed by the engineer - in charge. 70 Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights.The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc.The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147.Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer 71 Refixing of damaged cement concrete solid block masonry in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work 72 Supplying and fixing of cement concrete solid block masonry by using solid blocks of size 400x200x150mm confirming to IS 2145-1965 made in CC 1:3:6 (One of cement, three of sand and six of course aggregate) using 6mm and below HBG stone jelly with compressive strength of 50 kg/cm2 in cement mortar 1:5 (one of cement and five of sand ) including curing and neat finish etc., complete complying with standard specification and as directed by the departmental officers at site of work. 73 Supplying and providing chain link fence with RCC posts.The RCC postswill be of 2.5m c/c and of 2.75mheight.The post will be 100mm square at top and 150mm square at bottom 2.15m height above ground level and 0.60m below ground level, in R.C.C 1:1.5:3mix using 12 to 20mm gauge stone jelly with necessary reinforcement moulding work and rendering smooth with cement at 15kg/cu.m etc., complete and fixed in c.c. foundation in 1:4:8 using 40mm size stone jelly. The foundation is of size 45x45x90 with sand filling 15cm height. The fencing will be of chain link 75mm size, 10 gauge. The height of fence is 2.0m after leaving 75mm gap from ground level including fixing the fence with the posts using G.I binding wire, etc. complet.ISI STD 74 Supplying and fixing Country wood scantlings for door, windows, joints, rafters, etc., or any other works using country wood scantlings in following lengh and complete it in all floors including labour charges for the manufacture of frames as per standard specification. 75 Country wood scantlings below 4m in length 76 Providing two legged Scaffolding using 15cm dia casurina post of 4m over all length (3m height + 0.5m Projection + 0.5m into the ground) the distance between the two rows being 1.25 and the spacing of posts being 2.0m in both the rows with two horizontal posts with 0.5m. Overlap on either side and braces at 2.0m centre to centre including longitudinal and transvers middle braces to step up and providing a platform with country wood planks of 40mm thick and 1m width, etc. in acomplete from using coil and nails - 1RM 77 For Initial height of 3.00 metre 78 For every additional height of 2.5 m above initial height of 3 m 79 Supply and fixing of 3-seater metal garden swing chair with canopy of material and specifications: Seating capacity - 3 seater swing, Material- metal, Appearance - modern with canopy, Cushion - Included, Usage/Application - balcony, garden, lounge, etc., Cushion material - polyster, etc., complete, as directed by the engineer-in-charge 80 Supplying,erectingandFixingprecast reinforcementbench with back rest. Bench shall consist of 2 nos. L shaped bases support in natural cement color of thickness 100mm, back height 1000mm, front height 450mm, base width 620mm and 5Nos Reinforced Concrete planks in red colorandsizeof 1500x100x50mm and 1no. reinforcedconcrete plank of 150x200x50mm: manufactured by using M-30 grade concrete & reinforced suitably: all parts to be joined with galvanized nuts and bolts of suitable size. 81 Supply & placing of FRP heavy duty three compartment Dustbin of size 1200 x 450 x 900 mm with top cover 82 Supply & placing of light weight concrete Dustbin of size 450 dia x 900 mm with top cover 83 Supply and placing of Monkey DustbinFRP – 2 Layers to a height of 3½ and width of 2½ 84 WATER SUPPLY AND SANITARY WORKS 85 Supplying and fixing in position best approved of BIS quality 110 mm dia PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of U clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 86 Supply and providingPriming Tank made up of PVC, Make: SINTEX / EQUIVALENT 87 Internal water supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 88 For laying PVC pipes of dia 32mm 89 External Water Supply - Supplying, laying and jointing PVC pipes (having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using PVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The PVC pipes shall be got approved by Executive Engineer before use on works. 90 Above Ground Level 91 For laying PVC pipes of dia 40mm 92 Below ground level 93 For laying PVC pipes of dia 50mm 94 For laying PVC pipes of dia 40mm 95 For laying PVC pipes of dia 25mm 96 Supplying, laying and jointing CPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.(Above Ground Level) (Internal Water supply) 97 Above Ground Level 98 For laying CPVC pipes of dia 32 mm 99 For laying CPVC pipes of dia 25 mm 100 Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements).The valves to be used on work shall be got approved by the Executive Engineer before use on work. 101 Gate valve 102 Fixing Gun Metal Gate Valve of 25 mm 103 Fixing Gun Metal Gate Valve of 40 mm 104 Wheel valve 105 Fixing Gun Metal Wheel Valve of dia 25 mm 106 Fixing Gun Metal Wheel Valve of dia 40 mm 107 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 50 mm ( 2 ) 108 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 40 mm ( 1.5 ) 109 Providing, fixing, Testing & Commissioning of PVC Ball valve with quarter turn including all necessary fittings & accessories complete. PIMTAS / AQVASTAR make 25 mm (1.00”) 110 Supplying and fixing in position 15mm dia brass CP Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 111 Supplying and fixing in position Health faucet of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary.(Taps should be got approved by the Executive Engineer before use on the works). 112 Supplying and fixing in position best quality and approved make Indian made white / colour glazed earthernware wash hand basin of size 550 x 400mm (with pedestal / without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia B class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). 113 White Glazed Wash Hand Basin 114 With Pedestal 115 Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks). 116 Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works). 117 Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications.(The soap tray should be got approved by Executive Engineer before use on works). 118 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level. 119 For laying PVC pipes of dia 110 mm 120 Supplying and fixing in position PVC cowls of 110 mm dia of best approved quality conforming to BIS, etc., complete complying with standard specifications.(The PVC cowl should be got approved by the Executive Engineer before use on works). 121 Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with P or S trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers.(The water closet should be got approved by the Executive Engineer before use on works). 122 Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm P or S trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications.(The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works). 123 White glazed European Water Closet with 10 litre capacity PVC flushing tank fixed on to wall 124 Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers.(The urinal should be got approved by the Executive Engineer before use on works.) 125 Supplying and fixing position CI Nahani Trap / Floor Trap of the following sizes with best stainless steel gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the CI / PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works).Nahani Trap of size 100 x 75mm with stainless steel gratings 126 Supplying and fixing in position 150 x 100mm P or S stoneware gully trap A grade with CI double gratings of size 150 x 150mm and 230 x 230mm at bottom and top respectively with necessary earth work excavation laid over a bed of brick jelly cement concrete 1:3:6 (One cement, Three sand and Six broken brick jelly) 150mm thick using 40mm size broken brick jelly including necessary brick work and plastering including dismantling masonry wherever necessary and re-doing the damaged portions to the original conditions using cement concrete 1:3:6 using 20mm stone jelly for fixing the gully trap and giving connections to stoneware sewer line etc., complete complying with standard specifications. [Earth work excavation, brick work, plastering shall be measured and paid separately]. The stoneware gully trap should be got approved by the Executive Engineer before use on works. 127 Supplying and fixing single phase 1 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 1 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 1 for the 1 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 128 Construction of Inspection chamber of size (clear 0.60x0.60x1.00) with necessary earth work excavation, sand filling, CC 1:5:10, brick work in CM 1:5, plastering in CM 1:5 12mm thick, Plastering in CM: 1:3 20mm thick, Precast slab 50mm thick, fabrication etc. complete as directed by the engineer-in-charge 129 Providing rain water recharging collection pit having a size of 900mm dia to a total height of 1200mm is 150mm above ground level and 1050mm below ground level with necessary augar bore of300mm dia to a depth of 3000mm from bottom level of collection pit and filled with 20mm HBG stone jelly inside of augar bore. The sides of collection pit provided with RCC Well ring of inner size of 900mm x 300mm x 50mm with 6mm reinforcement on both directionat 200 mm c/c using RCC 1:1/2:3 (one cement, one and half sand and three HBG jelly). The top of collection pit is finished with 50mm thick cover slab, The collection pit is filled with course river sand at top, 20mm HBG stone jelly at middle and 40mm HBG stone jelly at bottom of a depth of 300mm, 450mm and 450mm respectively. The rate is including the cost of RCC well ring and filling materials, RCC cover slab, drilling hole and labour charges for erecting the well ring etc.,and as directed by the departmental officers. 130 Supply, Fixing & commissioning of Pop up spray RD 1804 SAM PRS Series Spray bodies with high efficiency HE VAN Nozzle capable of covering radius of 0.9-4.6m at 1.0 - 2.1 Bars, pressure with Matched precipitation rate, tactile click and DU >0.7. Triple Blade Wiper Seal precisely balances flushing, flow- by and debris protection to optimize performance and durability at pop up and retraction. Precision-controlled flushing at pop-up and retraction clears debris, ensuring positive stem retraction in all soil types. Unique debris pockets hold grit in place, removing it from circulation and preventing long-term damage. Parts resistant to corrosion in treated recycled water containing chlorine. Pop spray body shall with stand upto 6.9 bar. Built-in Seal-A-Matic™ (SAM) check valve. Traps water in lateral pipes in elevation changes of up to 14 feet (4.2 m). PRS Maintains constant outlet pressure at 30 psi or 45 psi at varying inlet pressures. etc., RD1804- SAM PRS-HE VAN incl installation charges 131 Supply of large capacity Disc filter 25 M³ / Hr including installation charges. (brands like Rain Bird or equivalent) 132 Flexible polyethelene irrigation pipe 16 mm dia / 2.5 / 1.1 - 1.4 mm CL - II. Netafim including installation charges. 133 Supply of endcap, nipple, start nipple, rubber grommet 16 mm dia. Netafim including installation charges. 134 Supply of Pressure compensated dripper with 2 / 4 / 8 LPH outlet flow. Rain Bird / Netafim make including installation charges 135 Supply of Micro sprinkler of half & full circle with 55 LPH output flow with necessary micro tube & stake. Rain Bird / JISL make including installation charges. 136 BOREWELL 137 Drilling of 12 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by the TWAD Board Officers including Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers etc 138 Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to required dia direct or reverse rotary mud circulation method using rotary rigs, fuel, labour and drilling bentonite and water required for drilling at site ( Site will be shown by the TWAD Board Officers) including construction of mud pit 139 Drilling of 140/150 mm pilot bore - Upto 60 m Depth ending below ground level 140 Drilling of 140/150 mm pilot bore - From 60 m upto 90 m Depth ending from ground level 141 Drilling of 140/150 mm pilot bore - From 90 m upto 120 m Depth ending from ground level 142 Reaming 300 mm dia pilot bore to 400mm/ 450mm dia bore as directed by the TWAD Board Officer. 143 Upto 60 m depth ending below ground level 144 Reaming 140/150 mm dia pilot bore to 300mm dia bore as directed by the TWAD Board Officer. 145 Upto 60 m depth ending below ground level 146 From 60 m depth and upto 90 mt depth ending below ground level 147 From 90 m upto 120 mt depth ending below ground level 148 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 2010 149 200mm dia CS 150 150mm dia RS 151 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 152 200mm dia CS 153 150mm dia RS 154 Supplying and filling with river pebbles in annular space between bore and PVC pipe up to hard rock 155 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including ransportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yieldtest by V notch method. 156 Supply ,erection and testing & commisioning of 3HP submersible pumpset in the to suit 200mm borewell of capacity of 4800 LPH @ 265Ft, max. total head of 280 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge and other required supporting items like SS hose nipple, nylon rope, clamps, bolt and nuts,GI nipple, 50mm dia HDPE hose of required length etc completed and as directed by the officer incharge. 157 Supplying and fixing single phase 5 HP Monoblock pumpset as per I.S.I. specification on suitable pedestal with foundation bolt and nut including labour. Supply and fixing of starter and main switch suitable for 5 HP pumpset on suitable angle iron frame work with necessary labour including panel board.Supply and fixing 1 No. foot valve 2 for the 5 HP Mono block pumpset supply and run of 4 of 10 sq.mm. in PVC pipe with 14 SWG TC wire etc., complete. 158 LANDSCAPING WORK 159 Supply & stacking of red earth at site to the departmental guage for pre-measurements which is of light textured, crystalline, porous and friable and not of generally acidic or neutral but not of alkaline and should be fertile, including seignior age charges, cost of transportation, loading, unloading, stacking and inclusive of all taxes etc., complete. 160 Supply of well decomposed Farm yard Manure in a powdery form, devoid of soil sand, stones, plastics and other materials, highly nutrient and which supports plant growth. 161 Supply and stacking of pit sand / earth filling sand at site to the departmental gauge for pre measurements obtained from sand deposits and should clean without solid particles 162 Mixing charges of Red soil, sand and manure uniformly (1:1:1) for Preparation of soil mixture (excluding material cost) 163 Spreading of red soil, gravel or sand including watering and rolling which hand roller for every 75 mm thickness - including hire charges of roller 164 Preparation of Mounds of various size and shape by availlable excavated/ Supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer - in - charge 165 Planting of Lilly - Hymenocallis Lilly (Spider liiy) shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 166 Planting of Plumaria Dwarf ornamental foliage Specimen plant variety of height 105- 120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 167 Planting of Duranta new gold Plant ornamental foliage shrub variety of height 30-45 cm in polythene bag of size 6x7 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 168 Supplying and Planting of Peltophorum tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 169 Planting of Bougainvillea Specimen plant variety of height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 170 Supplying and Planting of Picharidia palms variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5cm dia casurina pole of 10 height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 171 Supplying and Planting of Roystonea regia (Royal palms) palm variety of height 180-210 cm in polythene bag of size 16x16 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 172 Supplying and Planting of Pungam tree sapling of height 240 –300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 173 Supplying and Planting of Bauhinia purpurea tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed bythe site in-charge. 174 Supplying and Planting of Spathodea campanulata tree sapling of height 240 – 300 cm in polythene bag of size 20x21 inch including supporting stack of 5 cm dia casurina pole of 10 feet height, including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in charge. 175 Supplying and Planting of Cane Bamboo tree sapling of height 300 - 360 cm in polythene bag of size 15x16 inch including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge 176 Planting of G2 grass including loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 177 CHILDREN PARK AND GYM EQUIPMENTS 178 Supply and fixing of Straight Slide - 7ftLength 450cm ( 15ft ) x Width 75cm ( 2.5ft ) x Height 210cm ( 7ft ) Slide Material : Polyethylene Slide. Slide Length : 21cm ( 7ft ), Slide platform height : 120cm ( 4ft ), Base platform size : 2ft x 2ft, Platform base : Aluminium Checkered Sheet. Center Post : 114mm OD Galvanized post, Side Post : 50mm (2) OD Galvanized post, Powder coating : Electrostatic pp coating on metal parts. Area Required : Length 600cm ( 20ft ) x Width 150cm ( 5ft ) Playing age group : 3 - 10 yrs. Children capacity : 1Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 179 Supply and fixing of Park Spiral Slide Junior (FRP)Size: L10.5 x W6 x H7Safe Area Size: L20.5 x W5 x H11.5Material specifications:Ladder : Galvanished ‘B’ Class pipe Sliding chute 9ft BED LEG :Galvanished ‘C’ Class pipeFRP thickness 4mm. (Reinforced Polymers in 5 Layers) 450 CSM Matt, 600 Roving Mat, Isotolic gel coat with PU pigment.ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality Glossy paint with primer 180 Supply and fixing of Cross Swing - 3 Seater Length 390cm ( 13ft ) x Width 120cm ( 4ft ) x Height 225cm ( 7.5ft ) Swing Seat material : LLDPE seats fitted with Stainless steel hooks. Swing Chain : PU coated coated galvanized chain Imported. Swinging Hook : Heavy duty Aluminium pressed with sealed bearing. Swing post : 114mm ( 4.5 ) OD G.I post of wall thickness 2mm, Centre post : 114mm ( 4.5 )OD G.I post of wall thickness 2mm, Playing age group : 3 - 12yrs. Children capacity : 3Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. Swing chain made of PU coated chain , Seat made of LLDPE ( Polyethylene), Swing hooks made of Aluminium with sealed bearings.4. All fastners closed with polyethylene caps for children protection. 181 Supply and fixing of Seesaw - SingleLength 210cm ( 7ft ) x Width 90cm ( 3ft ) x Height 60cm ( 2ft )Seesaw seat material : LLDPE - Polyethylene. Qty : 2Nos.Seesaw center & side post : 89mm ( 3.5 ) OD Galvanized post,Seesaw handle post : 32mm ( 1.2 ) OD Galvanized post,Seesaw post top cap : Heavy duty Aluminium,Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 300cm ( 10ft ) x Width 210cm ( 7ft )Playing age group : 3 - 10yrs.Children capacity : 2Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 182 Supply and fixing of Park Seesaw 4 Seater (FRP Seat)Size: L8.75 x W5 x H3 Safe Area Size: L11.75 x W8 x H6 Material specifications:Frame : 1 ½” Galvanished ‘B’ Class pipeSee saw Rail :2” Galvanished ‘C’ Class pipeSeat : FRP Seat with 450 CSM Mat 3 Layers bonding. Isotolic gel coat with UV pigment.Painting with PU coating seatISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball Bearing 183 Supply and fixing of Merry go round - 6 Seater Diameter 180cm ( 6ft ) x Height 75cm ( 2.5ft )Galvanized 50mm dia pipe used for outer ring.Heavy duty Tapper roller bearing setting on the base for smooth rotation.Powder coating : Electrostatic pp coating on metal parts.Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )Galvanized semi circle seats - 2Nos with side saftey handles.Playing age group : 3 - 12yrs.Children capacity : 6Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 184 Supply and fixing of Spring Rider - Dinasour Polyethylene Dinasour design attached with 22mm heavy duty coil springs mounted on 10mm Base plate. Metal part powder coated. Safe area - 6ft x 6ft. Playing age group : 3 - 10yrs. Children capacity : 2 Specification of Material:1. All Metal posts are made of Galvanized pipes with elecrostatic powder coated.2. Play components are made of Linear low density polyethylene (LLDPE ) ,UV protected, Heat resister, smooth finished with elegent designs. 3. All fastners closed with polyethylene caps for children protection. 185 Supply and fixing of Park Loop RungSize: L10 x W2 x H7.5Safe Area Size: L13 x W5 x H10Material specifications:Post-Galvanished ‘B’ Class pipeTop rail-Galvanished ‘C’ Class pipeSprings –Galvanished ‘C’ Class pipe.Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 186 Supply and fixing of Park Flat RotorSize: L5 x W5 x H3.25’ Safe Area Size: L8 x W8 x H6.25Material specifications:Pipes - 1’’GI pipe, 3/4”GI pipe, 3”GI pipe, 2.5mm thick, B class paint: PU coatingISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 187 Supply and fixing of Park Arch Swing 2 Seater (FRP)Size: L10 x W3 x H6.75Safe Area Size: L13 x W6 x H10Material specifications:ARC-Frame : 2.5mm thickness Galvanished ‘B’ Class pipe Top Rail : 2” Galvanished ‘C’ Class pipe with 4.5mm thickSeats : RubberChain : 8mm Stainless Steel Chain (Grade-304)Painting with PU coating ISI Make pipe and MS Angle and Flat with high thicknessHigh quality NTN Ball BearingHigh quality FRP Materials with U~V resistance pigments and ISO Resign and 600 GSM Mat 188 Supply and fixing of Air Walker Single personSize: L3.75 x W1.25 x H5 Safe Area Size: L6.75 x W4.25 x H8Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes (1680 x 515 x 1780 mm) 4 mm pipe Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 189 Supply and fixing of Chest Press - Single PersonSize: L7.5 x W2.5 x H6Safe Area Size: L10.5 x W5.5 x H9Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes. Double coated Powder coating, Heavy duty Branded sealed Ball bearing, Steel & foot rest / Foot Paddle for long lasting life 190 Supply and fixing of Leg Press - Dual PersonDimension : L 120cm ( 4ft ) x W 45cm ( 1.5ft ) x H 130cm ( 4.3ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Twister Base : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 191 Supply and fixing of Push Up / Pull BarSize: L3.5 x W3.5 x H6.5Safe Area Size: L6.5 x W6.5 x H9.5Material specifications:Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. Steel Foot rest / Foot Paddle for long lasting life. 192 Supply and fixing of Shoulder Wheel - Single PersonSize: L2 x W2.5 x H6.25Safe Area Size: 4 x 5.5 x 9.25Material specifications:4mm pipe thick Main Post made of 4 Inch Pipe and other main pipes 1-1/2 inch Pipes. 3 mm thickness pipes Double coat Powder coating, Heavy duty Branded sealed Ball bearing, for long lasting life. 193 Supply and fixing of Excer CycleProduct Dimension : L 85cm ( 2.8ft ) x W 83cm ( 2.7ft ) x H 182cm ( 6.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Rotating Knobs : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 32mm / 1.25 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 194 Supply and fixing of Lat Pull Down - Single personDimension : L 100cm ( 3.3ft ) x W 75cm ( 2.5ft ) x H 180cm ( 6ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Handle grips : HD Rubber coated. Seat & Back rest : Polyethylene. Bearing setting for smooth rotation. Main Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Handle Post Size : 50mm / 2 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 180cm ( 6ft ) x Width 180cm ( 6ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 195 Supply and fixing of Sit Up BoardDimension : L 142cm ( 4.7ft ) x W 112cm ( 3.7ft ) x H 63cm ( 2.1ft ) Material : Galvanized Steel. Fastners : Stainless steel 304 grade with Polycaped. Post top Cap : High density Aluminium. Base material : 25mm OD Galvanized Oval pipes. Post Size : 115mm / 4.5 OD G.I post of wall thickness 3mm. Post Size : 45mm / 1.5 OD G.I post of wall thickness 3mm. Powder coating : 80 micron Akzo nobel electrostatic coated. Area Required : Length 240cm ( 8ft ) x Width 240cm ( 8ft )All Metal posts are made of Galvanized pipes with elecrostatic powder coated. 196 KIOSK 197 ACP KioskSupply of Kiosk: MS Tube Frame Covered with ACP Panel Size: 3m x 2m Bottom: Bison Board 1” Thick Front: Large Door with Double Piston Left Side: Access Window Right Side: Main Door With Lock Top: ACP Sheet (Puff Panel) Table: 7.5Ft x 1.5’ Width 1no Accessories: Fan 1No, Tube light 2Nos, Switch Box 1No, MCP 1No, Exhaust Fan 1No, Wash Basin 1No, Vinyl Flooring, LED Name Board with Logo, Menu Card 198 ELECTRICAL WORKS 199 LT CT TNEB METER BOX: Supply, Installation, testing and commissioning of compartmentalised LT 3Phase, TNEB Metering box of outdoor weather proof type with MS mounting stand, Test Terminal Blocks, Internal control wiring etc., as per local TNEB standards. The box suitable for 3phase 100A service connection made up of with hylem sheet of size 2feet x 1-1/2feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of3Nos.100A fuse units (500V),1No.neutral link,copper earth flat of size1x1/4 with interconnection of EB meter tofuse units by 16 Sq.mm PVC insulated copper wire with suitable necessary connection with earth connection complete. 200 Supply and fixing of 125A TPN Isolator in sheet steel enclosure with double breakon suitable angle iron frame work with MS cable entry boxes with earth connection only. 201 MAIN LT PANEL: Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base frame, double internal earthing arrangements, 125Amps, rating TPN Copper busbars with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 125Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMMetering : 1 Set of RYB LED Indication lamps1 No. of Multifunction Meter with RS 4851 Set of Current Tranformers (125/5A, Cl-1), 1 No. 125/5A CT for APFCR1 Set of Control MCBs Outgoings: 7 Nos. 63Amps, TP+N MCCB 2 Nos. 32Amps, TP+N MCCB3 Nos. 25Amps, DP MCB[Size:2400mm (L) x 350mm (D) x 2000mm(H)] 202 APFCR PANEL - 25KVAR: Supply, Installation, testing and commissioning of 3Phase, 415Volts, 25KVAR rating APFCR (Capacitor) Panel board of Indoor, Cubicle floor / wall mounting type made out of 2mm thick CRCA Sheet with powder coated finishing, MS base /wall frame, double internal earthing arrangements, 63Amps, rating TPN Copper busbars with interconnection busbar, etc., (1 x 10KVAR + 2 x 5KVAR + 1 x 3KVAR + 1 x 2KVAR) 203 12WAY Outdoor Lighting DB - 1 to 5: Supply, Installation, testing and commissioning of Outdoor weather proof type 3Phase Outdoor Lighting DB comprising of 1 No. 63Amps, TP+N, MCCB with Extended RHOM as incomer with RYB LED Phase indication lamps, 3Phase 63Amps, 4Pole Timer internal control wiring, etc., Outgoings: 11 Nos. 16A-32Amps, 4P MCBs &3 Nos. 20Amps, DP MCBs including Copper busbar connections, interconnection cables, cable entry provisions, floor mounting frame (600mm to 900mm), etc., 204 SLDB-1 to 4 and ELV UPS DB: Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 205 Pump room DB - 1 & 2: Supply and fixing of 8 way Vertical Triple pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1 no. 63A 4P MCB switch as incoming and 5 nos. 32A 3P MCB, 9 nos. 6A to 32A SP MCB as outgoing on wall with earth connection only. Higher End 206 SupplyandLayingof31/2 Corex120 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 207 SupplyandLayingof31/2 Corex70 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good 208 SupplyandLayingof31/2 Corex50 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 209 SupplyandLayingof31/2 Corex95 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 210 SupplyandLayingof31/2 Corex25 sq.mm.PVCarmouredLTUGcablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 211 Supply and Clamping of 2 core x 10 Sq.mm PVC armoured LTUGaluminium cable on post or on wall MS-clamps, saddles, plugs, screws etc., complete including transport charges of UG cable. 212 Supply and fixing of brass cable gland for 2 x 10 sq.mm. PVC armoured LTUG cable with earth connection 213 Supply and fixing of brass cable gland for 3-1/2 x 25 sq.mm. PVC armoured LTUG cable with earth connection 214 Supply and providing cable end termination of 3-1/2 x 25 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 215 Supply and fixing of brass cable gland for 3-1/2 x 50 sq.mm. PVC armoured LTUG cable with earth connection 216 Supply and providing cable end termination of 3-1/2 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 217 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection 218 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 219 Supply and fixing of brass cable gland for 3-1/2 x 95 sq.mm. PVC armoured LTUG cable with earth connection 220 Supply and providing cable end termination of 3-1/2 x 95 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 221 Supply and fixing of brass cable gland for 3-1/2 x 120 sq.mm. PVC armoured LTUG cable with earth connection 222 Supply and providing cable end termination of 3-1/2 x 120 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete 223 Supply and erection of GIHotDip/PowderCoated16SWGPerforated type CableTraywith 300mm width and 50mm height with all the fixing accessories 224 Supply and Run of 2 of 2.5 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe Concealed inwall and ceiling with continuous earth wire connection of 2.5 sq mm copperwire and making good of the concealed portion 225 Supply and Run of 2 of 6 sq.mm.PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable gauge MS conduit pipe concealed inwall and ceiling with continuous earth wire connection of 6 sq mm copperwire with painting of suitable colour. 226 Supply andrunof2 of4 sq.mm. PVC insulatedSC unsheathedFRLS copperconductorof1100V gradeinsuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm copper wire and making good of the concealed portion wiith suitable colour 227 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 228 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 229 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 230 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End (Primary) 231 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 232 Supply and erection of 20Watts, 4 Feet LED Fitting with LED (Higher end) end cap, PVC unsheathed copper leads from terminals to the fitting and fixing accessories 233 Supply and fixing of 60Watts All-in-One (AIO) Model Solar Street Light with 6000mm Height pole with base plate and all the fixing accessoriesThe cost is inclusive of civil foundation works including anchor fasteners,etc., as per site requirements 234 Supply and fixing of 3W RGB Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KLITE:4092 - symmetrical Inground 235 Supply and fixing of spike light 6W fitting on floor with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. KL-Trioscope - 7052 236 Supply of One No of 9.5 mtr. Street Lamp Post With 2.7 mtr Arch Double Bracket, 1 No. of 4 Core SMC Fuse Box With Hot Dip Zinc Galvanising 237 Cost of Erection & Materials Required For 9.5 mtr Street Lamp Pole With Brackets Conventional Foundation(Material Ratio - 1:1.5:3) 238 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 239 Supply and fixing of MS / Fibre Louvers Shutters arrangements for 300mm ACExhaust Fan (M-1346) 240 Supply and fixing of 1200mm (48) sweep AC ceiling fan 5 star ratedcomplete ( Higher end)with 2 module 100W fan step regulator (Higher end)with 1 metre down rod with fan clamp with side plates and cross arm of size 450mm (18) 241 Supply and fixing of Maintenance Free earthing with Copper rod of 17.2 mm dia and 3m length including all the civil works 242 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 243 Supply and Run of1 of No.8 SWG copper wire for earth connection 244 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 245 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS 246 Supply of First Aid Box complete with all First Aid Medicines 247 Supply and fixing of Shock Treatment chart with Glass frame(in English & Local Language) 248 Supply and fixing ofMetallic Danger Board as required by the Electrical Authorities (415Volts & 230Volts) 249 Supply and Installation for 2KVA, UPS (Single Phase Input & Single Phase Output) Capacity with 2Hourse Battery back up, battery stand and interconenction cables. 250 Supply and fixing of 40Amps, 30mA DP RCCB in a suitable sheet steel enclosure and necessary fixing accessories (Higher end) 251 CCTV SYSTEM 252 Supply, Installation, Testing and commissioning of 32 channel 8 SATA NVR, with 10TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. 253 Supply of 4MP, Internet Protocol fixed BULLET CAMERA (OUTDOOR) with following specification:a) 1/2.5 Progressive Scan CMOS, b) 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)c) Face Detection d) 120dB WDR, e) BLC/3D DNR/ROI, IP67 compliedff) On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,g) Shutter Speed 1/3 s to 1/100,000 s, h) 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, i) rotate: 0° to 360°, 2.8 mm, j) horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, k) Lens Mount M12 & IR Range I5: up to 50 m, l) Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, m) Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9Wn) Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand. 254 Supply of 8MP, Internet Protocol fixed BULLET CAMERA with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behavior analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse with suitable Stand. 255 Supply, Installation, Testing and Commissioning of 55 smart LED TV with following specifications a) Resolution: Ultra HD (4K) 3840 x 2160b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -2nos n) Built in LAN o) Magic remote 256 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant.Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 257 Supply and laying of armoured, Multimode, Thermoplastic Tape Inner Sheathed, PVC type sheathed 6 core Optical Fibre Cable withunique fiber excess length control method provides the cable with excellent mechanical and environmental properties and Cable - 2 Embedded FRP provides tensile strength & Anti-buckling properties. It is processed with Filling jelly - Thixotropic jelly to prevent Water ingress in loose tube. 258 Supply and Termination of Optical Fibre Cable Single Point ( Point to Point ) Splicing and arrangement charges. 259 Supply and fixing of POE 8port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 260 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 261 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. 262 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 263 Supply and fixing of outdoor 4X6PVC box with 102mmX77mmX102mm with all fixing accessories. 264 Supply and Erection of 6mtrLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges.The Pole Should be hot dip Galvanized confirming to BESN ISO-1461 with thickness of 65 Micron 265 PA SYSTEM 266 Supply, Installation,Testing & commisioning of 30 watts 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn WALL / COLUMN speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. 267 Supply, Installation,Testing & commisioning of 480 watts P.A Booster Amplifier with the output power of 1350 watts maximum, 500watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db. 268 Supply, Erection,testing & Commisioning of custom built table top 4 zone micro processor based 1 way announcement console cinsisting of teleline preamplifier , 1 x priority module , 12 zone selector module , all call switch module , tone oscilator modulefor fire evacation, press to talk switch module,goose neck microphone ,24v dc rectifier module, power supply uit , all call relay module etc as required.(Delegate unit) 269 Supply and Fixing of Rack with Accessories -Higher end6U Rack with fan extra for the above rack. (speaker/data/cctv) 270 Supply, run, testing and commissioning of2Core x 1.5sq sqmm PVC insulated Armoured Speaker Cable in suitable 25mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
38.
Housing Urban and Rular Development #10200585 Price Bid
Tender For Construction Of New Muthalvar Padaippagam At Bhakthavachalam Park, Chennai; 1 Civil Works 2 Dismantling removing the existing Reinforced Cement Concrete work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 3 Dismantling removing the existing Brick work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 4 Removing the existing ventilators,doors and windows including removal of frames ,hinges and fastenings arefully and stacking the same at site etc., complete. 5 Dismantling Floor finish and daddoing walls in cement mortar with mosaic tiles/glazed tiles/cuddapah slabs. 6 Carting away the surplus earth and debris to a lead of 5kgm.including Loading, unloading and dumping in the Corporation Land as directed during the execution. 7 Dismantling removing the existing closet, fitting, pipes, etc as per site., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 8 Civil Works 9 Providing and constructing cast in situ hydraulic bored piles of specified diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipments like piling rigs, temporary casing of appropriate length forsetting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method dulythrough all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). 10 Boring or chiselling through any obstacles, boulders, weathered rock, etc. Upto founding level of piles for seating resting or socketting of files. The rate quoted shall include demobilising the site with all plants, equipment, piling rigs, necessary personnel brought for piling work, including removal and transportation of debrise away as directed, cleaning and reinstating site to original condition as acceptable by the Architect on completion of piling work. 11 450 mm Dia 12 Carrying out initial working pile load test on specified dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. Instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete 13 Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers. 14 Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge. 15 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 16 Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation. 17 Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth. 18 Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over. 19 Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12 to a depth of 8 around the building before laying the plinth projection.This holes has to be be closed after the treatment. 20 Supplying and Filling withM-sand in floor and others sub structures for 150mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of river sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification. 21 Construction of Wet Mix Macadam 150mm compacted thickness in two layers by providing , laying , Paving , and compactingofaggregate gradation satisfying to Table 400-13 of MORTH and satisfying the physical paraeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mied material to work site and laid in sensorpavers to the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer-In-Charge of work. 22 Providing and laying plain cement concrete 1 : 4 : 8 ratio of(1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement for 100mm thick including dewatering wherever necessary and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification. 23 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 24 For column footing plinth beam , pile cap staircase steps, piers raft beam raft slab etc., 25 For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc., 26 For square or rectangular column, boxing, sunshade etc., 27 Providing and Laying M 30 Standardised concrete Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, retainning wall drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge 28 Basement 29 GF 30 FF 31 Terrace 32 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 33 Brick work in cement mortar 1:6(one cement and four sand) using fly ash bricks of size 230mmx110mmx70mm for foundation and super structure as per detailed specifications and as directed by the departmental officers 34 Ground Floor 35 First Floor 36 Terrace 37 Brick partition walls of 11.50cm thickness using best quality Fly ashbricks of size 9 x 4-3/8 x 2-3/4(230x115x76) in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 38 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc.. with cement Mortar 1:3 (1 of Cement : 3 ofP sand) according to the specification. The Rate including Cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 39 Plastering of 12 mm thick for Internal walls with cement mortar 1:4 (1 of cement : 4 of fine P.sand)according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 40 Plastering 12 mm thick for external surfaces with cement mortar 1:4 ratio (1 of cement : 4 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by theEngineer-in-charge. 41 Supply and painting oftwo coats of Plastic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer.Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge.(Internal surface) 42 Supplying and painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete.Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (M-0652) 44 Supplying and filling the sunken slabarea byBRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc.Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 45 i) Includingapplying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 46 Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 47 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 48 Providing and laying factory-manufactured linoleum flooring in the form of Rolls in the size of 12192mm of length and 1981mm of wide with 2mm thickness which laying above in the vertified tiles using the adhesive the flooring shall be laid over a smooth, level subfloor using manufacturer-recommended adhesives, complete in all respectsRoll flooring shall be laid with butt joints; edges shall be cold-welded or heat-welded for seamless joints.Apply a coat of linoleum polish or sealant after laying (if uncoated variant is used). Proper rolling to remove air pockets and ensure bonding the rate is inclusive of all necessary material, labour, transportation etc asper standards. 49 Finshing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in cement Mortar 1:3 (one cement and threee sand ) 12mm thick mixed with water proofing compound conforming ti ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed withred oxide and water proofing compound including curing et,. complete complying with standard specification and as directed by the departmental officers 50 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 51 Supply and laying with best quality the following materials of Machine Polished granite slab not less than 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge 52 Supplying and fixing plywood partition with Teakwood frames of75x50mm size and with 3mm thick commercial plywood fixedwith screws and nails including fixing in position with 4Nos of iron hold fasts 50x6x230mm size etc.,complete.(ISI STD) 53 Supply & fixing of Tamilnadu Logo & Symbols as per design & Elevation. 54 Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 55 Supplying and fixing UPVC windows of casement type Open from the profile the size of outer frame 60mm x58mm and shutter profileare reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm. TheEPDM rubber covered with over all the edges of frame and shutter the shutter .will be provided with Espag multi power point locks and also it operates with Handle. The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be provided to the shutter and it should not allow leakege of water even at most ranging storms and should have key lockable action, security protective hinges , strong locking system and as per size for arresting noise and energyloss. The connecting mechanism between sash and windowshould be fixed to the wall with 100% packing with screws and silicon Packing all roundthe frames. The window should be got approved from the Executive Engineer before use on work. 56 Providing of 35mm thick factory made pre-laminated ABS(Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x32mm, reinforcedby 32 x 32mm - 2 Nos., for vertical made out of LVL(Laminated Veneer Lumber), core material of 32mm thickhigh density craft paper honey comb board, sandwiched onboth sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of steel coated butterfly hinges - 3 Nos.,for each shutter and ISI make SS round lock complete forfinished item of work, complete complying with the standardspecification. The door shutter and frame should be gotapproved from the Executive Engineer before use on work. 57 FRP Door Sutter with FRP Door Frames along with vision panel (as per drawing) made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. 58 Supplying and fixing UPVC Louvered Ventilators of from the profile the size of outer frame 60mm x58mm and shutter profile size of 60mm x 78mm both profile are reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm.The EPDM rubber covered with over all the edges of frame and shutter . The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be providedin the Louvers.The window should be fixed tothe wall with 100% packing with screws and silicon packing all round the frames.The Ventilator should be got approved from the Executive Engineer before useon work. 59 FALSE CEILING WITH GYPSUM PLAIN TILES (600x600)Providing and fixing true horizontal level false ceiling using SAINT - GOBAIN GYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at 1200mm c/c max by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm(Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying with 12mm Gypsum plain Tiles as per stansdards 60 Providing & fixing of Brick Cladding in elevation as per drawing. The rate is inclusive of all necessary material , labour, transportation etc complete as per standards. 61 Supplying and Fixing of aluminium Dye Cast Letters of approved size and colour treatment processis achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes aluminium Dye Cast Letters 6 Size. Tamil Stainless Steel Letters 25CM 62 Supplying and fixing M.S.Grill gate of required size in two shutters with necessary iron members, gun metal cups and wheels 75mm dia. with fittings locking arrangements,etc., complete,including painting a priming coat of approved primer,etc., complete (The design of gate furnished is subject to alteration during execution.) 63 Supplying and Painting the wall with Texture Finish Paint including thorough scraping, clean removal of dirt, Primer. The rate includes cost of materials, brushes, sand paper, rollers, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) 64 GYPBOARD DOUBLE SKIN PARTITIONProviding and fixing of Gypsum Dry wall Double skin partition of 75 mm thick using SAINT - GOBAIN GYPROC or Equivalent make and the partition shall be of one layers of tapered edge 12.5mm thk Gyp board screw fixed with dry wall screw of 25mm at 300mm c/c to either side of 48mm studs. GI steel sections to be placed at 610 mm c/c in 50mm floor and ceiling channel 0.55mm thick having equal flanges of 32mm made of GI steel with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be finished so as to have a flush look which includes filling and finishing with jointing compound, joint paper and 2 coats of Drywall top Coat suitable for Gypsum upto primer level.As per India Gypsum Specs.Note: Angle Bead to be used at external angles to get straight line finish & protection from normal impacts. 65 Providing and laying water proofing treatment to vertical and surfaces for sunken portion of depressed portions of W.C., and the like consisting of :i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:2 (1 Cement : 2 Coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot at 1.7Kg per sqm of area. iv) 4th course of 400 micron thick PVC Sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm) 66 PLUMBING WORKS 67 Supply,erection and testing & commisioning of 3HP Submersible pumpset in the capacity of 6000 LPH @ 300Ft, max. total head of 350 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Sump to OHT transfer pump) 68 Labour charges for the erection of submersible pumpset in borewell/openwell including fixingand jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 69 Drilling of 6 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by theincluding Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. 70 300mm 71 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by V notch method. 72 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992 73 200mm dia CS ( plain pipe) 74 150mm dia CS ( plain pipe) 75 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 76 200mm dia CS ( plain pipe) 77 150mm dia CS ( plain pipe) 78 Supply and fixing in position whiteEuropean Water Closet of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.URINAL WITH FIXING ACCESSORIES SET, SIZE - URS-WHT- 13253N 79 Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia B Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass, wast couplingNipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers.(TheWash basin should be got approved by the Executive Engineer before use on works. 80 Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre longflexibletubeincludingcuttingandmakinggoodthe wallswherever requiredetc complete.complyingwithstandardspecificationandas directedbytheDepartmentofficers.Thequalityandmakeofhealth faucet should be got approvedby Concern department Engineer before use on work. 81 Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work. 82 Supplying and fixing in position Mirror of size 600x450mm of approved quality and brand with necessary plastic back PVC frame with bottom stand using brass screws rawl plugs for fixing etc complete complying with standard specification and as directed by the Departmental officers.The colour of frame and quality of mirror should be got approved by the Executive Engineer before use on work 83 Supplying,installing,testing and commissioning of approved make CONCEALED STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work. 84 Supplying and fixing CP angle cock with wall flange including cutting and making good the walls wherever required etc., complete complyingwithstandardspecificationandas directedbythe Engineer Incharge before use on work. 85 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg ,10 kg /sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 86 160mm Dia 6kg 87 110mm Dia 6kg 88 75mm Dia 6kg 89 50mm dia 6kg 90 Supplying andfixingPVC cowl of following size to vertical Soil/Waste pipes above terrace level. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge. 91 110mm dia 92 Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly limeconcrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) includingdismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ). 93 Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mixfor base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floatingcoat of neat cement ,supplying and fixing SFRC manhole cover with farame , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works) 94 Manhole 600 x 600 mm internal size ( Depth up to 1000mm) 95 Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesivesand fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.Internal & Vertical 96 a) 20 mm dia 97 b) 25 mm dia 98 c) 32 mm dia 99 Supplying and fixing manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by theClient / Engineer-in-charge.Size:600x600mm 100 Supply & fixing of Bottle trap as per standards. BOTTLE TRAP (WITH INTERNAL PARTITION) 32 - ALD-CHR- 769L300X190 101 LANDSCAPING WORKS 102 Planting of Ixora hybrid foliage shrub variety of height 30-45 cm in polythene bag of size 6x8 inchincluding loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 103 Planting of Ficus black ornamentalfoliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 104 Planting of Jasmine Plant foliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 105 Planting of Travellers palm ornamental foliage Specimen plantvarietyof height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 106 FURNITURE WORKS 107 Linear type Workstation (1000mm(W) X 600mm(D) X 750+300mm(H)) as per below specificationTable Top: - Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with 2mm PVC Edge Banding.Main Screen : -8mm Sandwitch Glass finishes of Sizes 1050x300mm htUnderstructure: - MS Square Leg cross-section of size 50 x 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm. Rectangular Tube made of 1.6mm thick CRCA Powder coated.Raceways : -Vertical Raceways - 120 MM HT MS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Without Middle Cover.Wire Manager: - Wire Manager Hole considered. 108 Storage (Open Shelf) 1200mm 300mm 2100mmIs made 25mm top & all other panel 17 mm thick in prelam particle board finished in Laminate of approved shape, equal shutter 2mm thick edge banding finished. This also includes providing and fixing of hardware like locks, handles, spring loaded hinges etc 109 Supply of Chairs 110 ASPIRE MB (BLACK)* Black Backrest frame, Polished aluminum connected* Mesh back, Seat and headrest fabric* Height adjustable lumbar support with PU surface* Tiltable backrest (can be tiltable when locked inupright position)* 4D adjustable armrest with PU pads* Mould foam with plastic seat upholstery* Mechanism, with seat slide.* Chrome gaslift* Polished aluminum base with plastic cover,* 60mm nylon castors 111 * Versa Medium Back Mesh Chair* AN -70 Mesh* Single Lock Synchro Mechanism* Adjustable Lumbar Support* One Way Adjustable Armrests ( Height)* Nylon Base* Fabric Upholstered Cushion Seat 112 Meeting Room TableTable Top: -Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with PVC Edge Banding,Understructure: - MS Leg 50mm 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm.Raceways : Horizontal RacewaysMS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Wire Manager:- Flip Cover Considered. 113 Meeting Room Table (2400mm 800mm 750mm) 114 Cabin Main Table with Side Storage (Main Table 1500mm 750mm 750mm / Side Storage 1200mm 450mm 750mm)Side Storage 1200mm 450mm 750mmTable Top: Main and Side Table Made of 25mm Thick E1 Grade Single Top PLPB with 2mm PVC Edge Banding,Understructure: MS Square 50mm Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50mm x 25mm.Flip Cover : Flip Cover 400*143mm Made of AluminiumWire Manager: Wire Box with Socket Plate and Vertebra considered for wiringModesty : Front & Side PLPB Modesty Panel . 115 Librarian TableMain Table 1100mm 440mm 750mm 116 3 Seater Sofa with Table 117 INTERACTS-902 (Leatherette)3 SeaterSize : 1810 (W) x 720 (D) X 740 (H)Made off : the sofa is made of fine quality leatherrite (3s = 8.0 mtr,2s = 6.8 mtr, 1s= 5.3 mtr), the structure is made from silver wood& pine wood, 32 & 40 density foam is used which is covered withroll poly filling for giving comfort and extra softness to sofa. Extra(kangaro company)Legs : are made of stainless steel.Color : Black 118 ELECTRICAL 119 TNEB METER BOX 120 Supply andfixng of TNEB meter board suitable for 3phase100A service connection made up of suitable angle iron frame work of size 2feet x 1-1/2 feet using angle iron of size1-1/2x1-1/2x1/4rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos.100A fuse units (500V), 1No .neutral link,copper earth flat of size1x1/4with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete. 121 M.S. Enclosure (IP65): Supply, Erection , Testing and commissioning of the followingtype M.S. powder coated enclosure for housing the Meteringing service, whch should be made outof16SWG enclosure with provision for cable entry, with Outdoorapplication IP65 as specified Protection, fixed on the wall/Floor withall accessories, pedestal frame with concrete grouting or suitable to fix at concrete plinth etc. 122 MAIN Panels 123 MAIN Panels:Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of14 SWG CRCA sheet steel with powder coated finishing, MS base frame, double internal earthing arrangements, 100Amps, rating TPN Copper busbars and Earth bar with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMDG Incomer: 1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMCommon C/O Incomer: 1 No. 100Amps, 4Pole Automatic Changeover Switch with EB ON and DG ON LED Indication lampsMetering : 2 Set of RYB LED Indication lamps2 Nos. of Multifunction Meter with RS 4852 Set of Current Tranformers (200/5A, Cl-1), 1 No. 200/5A CT for APFCR2 Set of Control MCB and Electrical Interlocking between EB & DG Incomers Outgoings: 3 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR &AC)4Nos. 32A, 25kA, TP+N, TM MCCB with Ext. RHOM (Lighting & Spare),6Nos 32A DB MCB inclding all labour Charges And Transports Charges. 124 APFC PANEL: Supply, installation, testing and commissioning of 25 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars, MPP type Power capacitors, with 5 KVAR x 3 no. 3 KVAR x 2 nos. 2 KVAR x 1 nos. 1 KVAR x 2no. Contactors, MCCB’s, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, Main panel sensing CT interconnecting wiring etc., all inclusive. 125 Supply, Installation, testing and commissioning of 1 x 58.5KVA, Silent type Diesel Generator Set with AMF Panel complete with suitable size Acoustic enclosure CPCB IV and BIS. Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS:5514, directly coupled to 58.5KVA at 0.8 Power factor, 415V, 3Phase , 4wires, 50cycles per second self excited, self regulated, with brushless excitation, Alternator generally confirms to BS:5000/IS:4722. DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with gauge board, andall other accessories as per standard specifications.Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be included in this item with Sutable concrete Base at M30 Grade. The DG Set shall be suitable for auto-mains failure startand auto / manualoperations.The DG Should be supplied with Auto-Start-Stop Control panel with suitable rating switchgear 126 DISTRIBUTION BOARDS 127 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 128 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution boardwith double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB asoutgoing in flush with wall with earth connection only. Higher End 129 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm.with the following in flush with wall with earth connection only. i. 63A 4P MCB - 1 no.ii. 63A 4P 30MA RCCB/ELCB - 1 no.iii. 63A DP MCB Isolator -3 nos.iv. 6A to 32A SP MCB - 12 nos., 130 Supply and Laying of 3 1/2x 70 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 131 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. 132 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 133 Run of Mains 134 Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 135 Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. 136 Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 137 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. 138 Point Wiring 139 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) Higher End Primary Point. 140 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator)Higher EndSecondary Point. 141 Switch & Sockets 142 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 143 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 144 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) on Suitable module concealedBox (GI ) in flush with wall with connections. Higher End 145 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) 146 Air Condition 147 Supply & Instalation of Air-Conditioner with Copper Coil 2.0 TR Split Type AC Unit - 5 Star Rated, 5 KVA capacity Automatic Voltage Stabilizer with time delay relay, 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit), Inculding MS stand for fixing outdoor unit. 148 Supply and fixing of Copper Refrigerant Piping of 3/8 dia and 5/8with Pipeline nitrle rubber insulation with 50mm PVC water drain pipe line with Non Adhesive Cotton Roll insulation and 3 core Power cable from indoor to Outdoor unit. 149 Supply and fixing of 450mm (18) Wall mounting 5 star rated complete (Higher end) with necessary accessories and hardwares as required. 150 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 151 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep AC exhaust fan 152 Supply and fixing of 24W LED 2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting 153 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 154 Supply, installation, testing and commissioning of36 W, 900mm diaCircular LED pendantlight fitting, made out of CRCA powder coated body, aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. KL 3232 155 Supply and fixing of28Watts GATE FIXTURE FITTINGwith cool day light suitable for wall / roof sheet mounting, made outCRCA powder coated body,IP65 aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.(Klite/Millenium/Bajaj Equivalent) 156 Supply and fixing of 8W Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. (Klite/Millenium/Bajaj Equivalent) 157 Supply and fixing of MIRROR Light 20W LED Batten 158 Supply and erection of Canon Digital Photocopier (Xerox) Machine IR-3300 / 3235Type of Product : Laser Multi functionalCore Functions: Print, Copy, Scan & SendFirst Copy Time:3.9 SecMultiple Copies :1 to 999 SheetsPrint Speed :45ppmThe laser beams engrave the image or text that you have sent to print on the surface of the drum. When using a copier this process is done using light, the light scans the page required for printing and converts it into an image 159 Supply and erection ofAll-in-one Desktop of HP 27-cb1456in Core i5 (8GB DDR4 /Windows 11 Home/27 Inch Screen/27-cb1456in) with 600VA UPS, Keyboard, Mouse,27 inches, 11th Gen Intel Core i5-1235U6 x 1.8 GHz (Turbo Speed upto 4.2 GHz) Cores Hexa Core, 12 Threads, 18 MB Cache, UHD Graphics 730 Graphics, 8 GB DDR4 RAM Smallest and 512 GB SSD.Ethernet (LAN), HDMI, Multi Card Reader,WiFi, Bluetooth v5.03 x USB 3.0, 1 x USB Type-C and Inbuilt Microphone 160 PRINTER: Supply, installation, testing and commissioning of HP Smart Tank 790 WiFi All-in-One Printer Duplexer with ADF and Magic Touch Panel Inkjet Colour printer, print speed 11-20 sheets with multiple features like print, scan, copy, fax, multi-port connectivity (Hi-speed USB 2.0, Wifi, Bluetooth LE , 1 USB Host, LAN) , 2.4/5G dual band Wi-Fi, Wi-Fi Direct, mobile printing capability, etc 161 Supply, installation, testing and commissioning of Long Range Wifi Device of following Specification: Networking Interface: (1) GbE RJ45 PortPower Method: PoE+, Pasive poE(48V) Max TX power: 2.4 GHzAntenna gain: 2.4 GHzMounting: Wall or Ceiling MountingWifi Satndards : 802.11a/b/gWireless security: WPA-PSK, WPA- Enterprises(WPA/WPA2/WPA3)VLAN: 802.1Q Concurrent Clients: 300+ 162 CCTV 163 Supply, Installation, Testing and commissioning of 16 channel 2 SATA NVR, with 6TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony. 164 Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand and camera fixed connecting box. (Make: Dahua/Panasonic) 165 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN (Make: Sony/ LG /Samsung). 166 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. ii)Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 167 Supply and Fixing of Rack with Accessories -Higher end9U Rack with fan extra for the above rack. (Amp/NVR/POE) 168 Supply and Fixing of Rack with Accessories -Higher end4U Rack with fan extra for the above rack. (speaker/data/cctv) 169 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 170 Supply and fixing of POE 8 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 171 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 172 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 173 Supply and Installation for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up and battery stand . 174 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 175 VOICE & DATA 176 Supply, Fixing and Termination ofRJ 11 Single Point ( Point to Point) Crimping, Testing and arrangement charges. 177 Supply & Installation of CAT 6 PVC Module Box I/o socket & face plate single socket Erection and arrangement chargers (Higher end) 178 Supply and fixingofLAN Network Switches Un-Managed 10/100/1000 - 24 Port and 24 Port Patch Panel- Unloaded erection and arrangement chargers. 179 Supply, runing, testing and commissioning of2 Pair Unarmoured 0.5mm Telephone cable in suitable Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 180 PA SYSTEM 181 Supply, Installation,Testing & commisioning of 15W Wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent) 182 Supply, Installation,Testing & commisioning of 120 watts P.A Mixer Amplifier with the output power of 120 watts maximum 160watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch) 183 Supply, runing, testing and commissioning of2Core x 1.5sq sqmm PVC insulated un Armoured Speaker Cable in suitable 20mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 184 Earthing 185 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm withcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnellingarrangementswithnecessary masonry work and with 38mm RCC cover slab for the brick masonry 186 Supply and erection of 17.2mm, 3mtr long, Copper Bonded earth rod with backfill compound, including civil worksof base PCC for chamber andheavy duty Chambercover,, heavy duty chamber cover, etc., as per IS 3043 standards 187 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 188 Supply and Run of1 of No.8 SWG copper wire for earth connection 189 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 190 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS(5 Nos) 191 Supply of First Aid Box complete with all First Aid Medicines 192 Supply and fixing of Shock Treatment chart with Glass frame 193 Supply and fixing of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle 194 Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms 195 Supply and fixing of Metallic Danger Board as required by the Electrical Authorities 196 METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following:1. Mudhalvar Padaipagam text in Tamil of size 20 x 15with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required. 197 LOGO SIGNAGE BOARD 198 LOGO SIGNAGE BOARDS: Supply and fixing of acrylic signages for the following:1. Mudhalvar Padaipagam logo of size 2 x 22. CMDA logo of size 2 x 33. Directorate of Public Libraries logo of size 3 diawith backlit LED placed over the sun board base, SIDE EDGES(4): 5mm transparent white acrylic sheet with laser cut & 4inches manual raising all around with details. ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS:Front: a. 5mm Imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine.b. Flexi bond make 25mm Sun board for the back of the logo.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
39.
Power #10172978 AOC
Tender For Annual Maintenance Repair Of Md Dvvnl Office Vidyut Adhikari Colony At 220 Kv Sub Station, Sikandra, Agra - Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: (DSR 2.1) All kinds of soil (DSR 2.1.1) 2 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. (DSR 2.6) All kinds of soil (DSR 2.6.1) 3 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(DSR 2.8) All kinds of soil. (DSR 2.8.1) 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift. (DSR )(DSR 2.25) 5 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. (DSR )(DSR 2.25(a)) 6 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. (DSR 2.26) All kinds of soil (DSR 2.26.1) 7 Supplying and filling in plinth withsand under floors, including watering, ramming, consolidating and dressing complete. (DSR )(DSR 2.27) 8 Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. (DSR 2.28) All kinds of soil (DSR 2.28.1) 9 Ploughing the existing ground to a depth of 15 cm to 25 cm and watering the same. (DSR 2.29) All kinds of soil (DSR 2.29.1) 10 Excavating holes more than 0.10 cum & upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m. (DSR 2.3) All kinds of soil (DSR 2.30.1) 11 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.31) 12 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. (DSR )(DSR 2.32) 13 Supplying chemical emulsion in sealed containers including delivery as specified. (DSR 2.34) Chlorpyriphos/ Lindane emulsifiable concentrate of 20% (DSR 2.34.1) 14 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along external wall where the apron is not provided using chemical emulsion @ 7.5 litres / sqm of the vertical surface of the substructure to a depth of 300mm including excavation channel along the wall & rodding etc. complete: 2.35.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.1.1) 15 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: 2.35.2 With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration (DSR 2.35.2.1) 16 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: 2.35.3 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.3.1) 17 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : 2.35.4 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration (DSR 2.35.4.1) 18 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : (DSR 2.35) Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. (DSR 2.35.5) 19 Extra for levelling & neatly dressing of disposed soil completely as directed by Engineer-in-charge. (DSR )(DSR 2.36) 20 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.2) 21 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.1.3) 22 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) 23 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : (DSR 4.1) 1:5:10 (1 cement : 5 fine sand derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.11) 24 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.2.2) 25 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.2.3) 26 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:2:4 (1 Cement : 2 coarse sand (zone-III)including manufactured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%)). (DSR 4.2.3A) 27 Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: (DSR 4.2) 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). (DSR 4.2.8) 28 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Foundations, footings, bases for columns (DSR 4.3.1) 29 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. (DSR 4.3.2) 30 Centering and shuttering including strutting, propping etc. and removal of form work for : (DSR 4.3) Columns, piers, abutments, pillars, posts and struts (DSR 4.3.3) 31 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. (DSR 4.4) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 4.4.1) 32 Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. (DSR 4.5) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) (DSR 4.5.1) 33 Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. (DSR 4.6) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.6.1) 34 Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : (DSR 4.7) 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR 4.7.1) 35 Precasting and placing in position 125 mm dia Bollards 600 mm high of required shape including providing M.S. Pipe Sleeve 50 mm dia 300 mm long in the Bollard and M.S. Pipes 40 mm dia and 450mm long with 150x150x6mm M.S. plate welded at bottom and embedded 150mm in cement concrete 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources), including necessary excavation of size 250x250x450mm deep for the same in bitumen/concrete pavement at specified spacing. (DSR )(DSR 4.9) 36 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources).(DSR )(DSR 4.11) 37 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. (DSR )(DSR 4.12) 38 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (DSR 5.1) C (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.1.2) 39 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : (DSR 5.2) 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR 5.2.2) 40 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.3) 41 Providing and laying reinforced cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.4) 42 Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.5) 43 Reinforced cement concrete work in chimneys, shafts, up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.6) 44 Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources). (DSR )(DSR 5.8) 45 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Foundations, footings, bases of columns, etc. for mass concrete (DSR 5.9.1) 46 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. (DSR 5.9.2) 47 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Suspended floors, roofs, landings, balconies and access platform (DSR 5.9.3) 48 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Shelves (Cast in situ) (DSR 5.9.4) 49 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Lintels, beams, plinth beams, girders, bressumers and cantilevers (DSR 5.9.5) 50 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Columns, Pillars, Piers, Abutments, Posts and Struts (DSR 5.9.6) 51 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Stairs, (excluding landings) except spiral-staircases (DSR 5.9.7) 52 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Chimneys and shafts (DSR 5.9.11) 53 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards(DSR 5.9.13) 54 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses, bands, copings, bed plates, anchor blocks and the like (DSR 5.9.15) 55 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Edges of slabs and breaks in floors and walls 5.9.16 Under 20 cm wide (DSR 5.9.16.1) 56 Centering and shuttering including strutting, propping etc. and removal of form for (DSR 5.9) Weather shade, Chajjas, corbels etc., including edges (DSR 5.9.19) 57 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.12) 58 Providing, hoisting and fixing up to floor five level precast reinforced cement concrete in small lintels not exceeding 1.5m clear span up to floor five level, including the cost of required centering, shuttering but , excluding the cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). (DSR )(DSR 5.13) 59 Providing, transporting, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete in lintels, beams and bressumers, including setting in cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering and shuttering but , excluding the cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) (DSR )(DSR 5.15) 60 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. (DSR 5.22) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22.6) 61 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (DSR 5.22A) Thermo-Mechanically Treated bars of grade Fe-500D or more. (DSR 5.22A.6) 62 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.1.1) 63 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (DSR 6.1) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.1.2) 64 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:4 (1 cement : 4 coarse sand) (DSR 6.4.1) 65 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (DSR 6.4) Cement mortar 1:6 (1 cement : 6 coarse sand) (DSR 6.4.2) 66 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. (DSR 6.13) Cement mortar 1:4 (1 cement :4 coarse sand) (DSR 6.13.2) 67 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab upto 0.50 sqm (DSR 8.2.1.1) 68 (DSR 8.2) Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble 8.2.1 Area of slab over 0.50 sqm (DSR 8.2.1.2) 69 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab upto 0.50 sqm (DSR 8.2.2.1) 70 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of colour black, Cherry/Ruby red 8.2.2 Area of slab over 0.50 sqm (DSR 8.2.2.2) 71 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. (DSR 8.2) Granite stone slab of all colour and texture except black, Cherry/Ruby red 8.2.3 Area of slab over 0.50 sqm (DSR 8.2.3.2) 72 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (DSR 8.3) Granite work (DSR 8.3.2) 73 Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. (DSR )(DSR 8.4) 74 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. (DSR )(DSR 8.5) 75 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. (DSR )(DSR 8.6) 76 Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) : (DSR 8.14) Red sand stone - exposed face fine dressed with rough backing. 8.14.1 30 mm thick (DSR 8.14.1.5) 77 Providing and fixing plywood 4 mm thick, one side decorative veneer conforming to IS: 1328 (type-1), for plain lining / cladding with necessary screws, including priming coat on unexposed surface with : (DSR 8.28) Decorative veneer facings of approved manufacture (DSR 8.28.1) 78 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 18 mm thick (DSR 8.30.1) 79 Providing and fixing skirting with Pre-laminated (one side decorative and other side balancing lamination) flat pressed 3 layer or graded particle board (medium density) Grade I, Type II, IS :12823 marked, with necessary fixing arrangements and screws, including drilling necessary holes for rawl plugs etc. and priming coat on unexposed surface complete : (DSR 8.3) 25 mm thick (DSR 8.30.2) 80 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 8.31) 81 Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. (c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium item.s The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. (DSR )(DSR 8.32) 82 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). (DSR 9.1) Sal wood (DSR 9.1.2) 83 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 35 mm thick shutters (DSR 9.5.1.1) 84 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hingesand necessary screwsshall be paid separately) (DSR 9.5) Second class teak wood 9.5.1 30 mm thick shutters (DSR 9.5.1.2) 85 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick : (DSR 9.7) Second class teak wood (DSR 9.7.1) 86 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 35 mm thick (DSR 9.9.1.1) 87 Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes (weight not less than 10 kg per sqm) fixing with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. (DSR 9.9) Second class teak wood 9.9.1 30 mm thick (DSR 9.9.1.2) 88 Extra for providing heavy sheet float glass panes instead of ordinary float glass in glazed doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) (DSR 9.11) 5.0 mm thick(weight not less than 12.50 kg per sqm) instead of 4 mm thick(weight not less than 10 kg per sqm). (DSR 9.11.1) 89 Extra for providing frosted glass panes 4 mm thick (weight not less than 10 kg per sqm) instead of ordinary float glass panes 4 mm thick(weight not less than 10 kg per sqm) in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured). (DSR )(DSR 9.12) 90 Extra for providing ISI marked Stainless Steel butt hinges instead of M.S. pressed butt hinges bright finished of required size with necessary screws. (Shutter area to be measured). (DSR )(DSR 9.14) 91 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Panelled or panelled & glazed shutters : 9.16.1 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.1.2) 92 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 9.16) Glazed shutters : 9.16.2 Second class teak wood including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.16.2.2) 93 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 12 mm thick (DSR 9.17.1) 94 Providing and fixing flat pressed three layer particle or gradedplain wood board medium density exterior grade (Grade I) FPT-I, conforming and markedto frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): (DSR 9.17) 18 mm thick (DSR 9.17.2) 95 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 18 mm thick (DSR 9.18.1) 96 Providing and fixing Pre-laminated flat pressed 3 layer (medium density) particle board or graded wood particle board IS : 3087 marked, with one side decorative and other side balancing lamination Grade I, Type II exterior grade IS : 12823 marked, in shelves with screws and fittings wherever required, edges to be painted with polyurethane primer (fittings to be paid separately). (DSR 9.18) 25 mm thick (DSR 9.18.2) 97 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.1) 98 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.20.2) 99 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. (DSR 9.2) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. Piano hinges IS : 3818 marked with necessary screws (DSR 9.20.3) 100 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.1) 101 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (DSR 9.21.2) 102 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: (DSR 9.21) 25 mm thick (for cupboard) including ISI marked nickel plated bright finished M.S. piano hinges with necessary screws (DSR 9.21.3) 103 Extra if louvers (not exceeding 0.2 sqm) are provided in flush door shutters (overall area of door shutters to be measured). (DSR 9.25) Decorative type door (DSR 9.25.1) 104 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). (DSR )(DSR 9.26) 105 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.1.1 Second class teak wood (DSR 9.27.1.1.1 ) 106 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :35 mm thick shutters (DSR 9.27.1) With ISI marked stainless steel butt hinges of required size 9.27.1.2 Second class teak wood (DSR 9.27.1.2.1) 107 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) with ISI marked M.S. pressed butt hinges bright finished of required size 9.27.2.1 Second class teak wood (DSR 9.27.2.1.1) 108 Providing and fixing wire gauge shutters using galvanized M.S. wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clerestory windows with hinges and necessary screws :30 mm thick shutters (DSR 9.27.2) With ISI marked stainless steel butt hinges of required size 9.27.2.2 Second class teak wood (DSR 9.27.2.2.1) 109 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50x12 mm (DSR 9.40.1.1) 110 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) 2nd class teak wood 9.40.1 50 x 20 mm (DSR 9.40.1.2) 111 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x12 mm (DSR 9.40.2.1) 112 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete : (DSR 9.4) Kiln seasoned and chemically treated hollock wood 9.40.2 50x20 mm (DSR 9.40.2.2) 113 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 20 mm dia (heavy type) (DSR 9.47.1) 114 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : (DSR 9.47) 25 mm dia (heavy type) (DSR 9.47.2) 115 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to steel windows by welding (DSR 9.48.1) 116 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. (DSR 9.48) Fixed to openings /wooden frames with rawl plugs screws etc. (DSR 9.48.2) 117 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 125x90x4.00 mm (DSR 9.56.1) 118 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 100x75x3.50 mm (DSR 9.56.2) 119 Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : (DSR 9.56) 75x60x3.10 mm (DSR 9.56.3) 120 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 125x65x2.12 mm (DSR 9.57.1) 121 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 100x58x1.90 mm (DSR 9.57.2) 122 Providing and fixing ISI marked IS:1341 oxidised M.S. pressed butt hinges with necessary screws etc. complete. (Copper oxidised as per IS 1378) (DSR 9.57) 75x47x1.70 mm (DSR 9.57.3) 123 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 150 mm (DSR 9.59.1) 124 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 125 mm (DSR 9.59.2) 125 Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.59) 100 mm (DSR 9.59.3) 126 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 150 mm (DSR 9.60.1) 127 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 125 mm (DSR 9.60.2) 128 Providing and fixingISI marked IS: 453 oxidised M.S. double acting spring hinges with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.6) 100 mm (DSR 9.60.3) 129 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 300x16 mm (DSR 9.62.1) 130 Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.62) 250x16 mm (DSR 9.62.2) 131 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 250x10 mm (DSR 9.63.1) 132 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 200x10 mm (DSR 9.63.2) 133 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 150x10 mm (DSR 9.63.3) 134 Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.63) 100x10 mm (DSR 9.63.4) 135 Providing and fixing ISI marked 85x42 mm oxidised M.S. pull bolt lock conforming to IS : 7534 with necessary screws bolts, nut and washers etc. complete (Copper oxidised as per IS 1378). (DSR )(DSR 9.64) 136 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 300x20x6 mm (DSR 9.65.1) 137 Providing and fixing ISI marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.65) 250x20x6 mm (DSR 9.65.2) 138 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 125 mm (DSR 9.66.1) 139 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 100 mm (DSR 9.66.2) 140 Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.66) 75 mm (DSR 9.66.3) 141 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 150 mm (DSR 9.67.1) 142 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 115 mm (DSR 9.67.2) 143 Providing and fixing oxidised M.S. hasp and staple (safety type) conforming to IS : 363 with necessary screws etc. complete (Copper oxidised as per IS 1378) (DSR 9.67) 90 mm (DSR 9.67.3) 144 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 125x64x1.90 mm (DSR 9.70.1) 145 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 100X58X1.90 mm (DSR 9.70.2) 146 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 75x47x1.80 mm (DSR 9.70.3) 147 Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : (DSR 9.7) 50x37x1.50 mm (DSR 9.70.4) 148 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 125x64x2.50 mm (DSR 9.71.1) 149 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 100x60x2.50 mm (DSR 9.71.2) 150 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete : (DSR 9.71) 75x50x2.50 mm (DSR 9.71.3) 151 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 250x10 mm (DSR 9.74.1) 152 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 200x10 mm (DSR 9.74.2) 153 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 150x10 mm (DSR 9.74.3) 154 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (DSR 9.74) 100x10 mm (DSR 9.74.4) 155 Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.76) 156 Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.77) 157 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. (DSR )(DSR 9.83) 158 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. (DSR )(DSR 9.84) 159 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 150 mm (DSR 9.87.1) 160 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 115 mm (DSR 9.87.2) 161 Providing and fixing bright finished brass hasp and staple (safety type) with necessary screws etc. complete : (DSR 9.87) 90 mm (DSR 9.87.3) 162 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.88) 163 Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. (DSR )(DSR 9.89) 164 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 40 mm (DSR 9.90.1) 165 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 50 mm (DSR 9.90.2) 166 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 65 mm (DSR 9.90.3) 167 Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. (DSR 9.9) Size 75 mm (DSR 9.90.4) 168 Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. (DSR )(DSR 9.91) 169 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 125 mm (DSR 9.92.1) 170 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 100 mm (DSR 9.92.2) 171 Providing and fixing chromium plated brass handles with necessary screws etc. complete: (DSR 9.92) 75 mm (DSR 9.92.3) 172 Providing and fixing chromium plated brass casement window fastener with necessary screws etc. complete. (DSR )(DSR 9.93) 173 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 125x63x4 mm (DSR 9.95.2) 174 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 100x63x3.2 mm (DSR 9.95.5) 175 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: (DSR 9.95) 75x63x3.2 mm (DSR 9.95.7) 176 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 300x16 mm (DSR 9.96.1) 177 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (DSR 9.96) 250x16 mm (DSR 9.96.2) 178 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 300x10 mm (DSR 9.97.1) 179 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 250x10 mm (DSR 9.97.2) 180 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 200x10 mm (DSR 9.97.3) 181 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 150x10 mm (DSR 9.97.4) 182 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.97) 100x10 mm (DSR 9.97.5) 183 Providing and fixing aluminium pull bolt lock, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws bolts, nut and washers etc. complete. (DSR )(DSR 9.98) 184 Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete. (DSR )(DSR 9.99) 185 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 125 mm (DSR 9.100.1) 186 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 100 mm (DSR 9.100.2) 187 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : (DSR 9.1) 75 mm (DSR 9.100.3) 188 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Single rubber stopper (DSR 9.101.1) 189 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. (DSR 9.101) Twin rubber stopper (DSR 9.101.2) 190 Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. (DSR )(DSR 9.103) 191 Providing and fixing aluminium tee channels (heavy duty) with rollers & stop end in pelmets as curtain rod. (DSR )(DSR 9.104) 192 Providing and fixing Bamboo jaffery/ fencing consisting of superior quality 25mm dia (Average) half cut bamboo placed vertically and fixed together with three numbers horizontal running members of hollock wood in scantling of section 50X25 mm, fixed with nails and G.I wire on existing support complete as per direction of Engineer-in-charge. (DSR )(DSR 9.110) 193 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Triple strip vertical type (DSR 9.114.1) 194 Providing and fixing magnetic catcher of approved quality in cupboard / ward robe shutters, including fixing with necessary screws etc. complete. (DSR 9.114) Double strip (horizontal type) (DSR 9.114.2) 195 Providing and fixing powder coated telescopic drawer channels 300 mm long with necessary screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.115) 196 Providing and fixing sliding arrangement in racks/ cupboards/cabinets shutter by with stainless steel rollers to run inside C or E aluminium channel section (The payment of C or E channel shall be made separately) (DSR )(DSR 9.116) 197 Providing and fixing 12 mm thick panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. (DSR 9.126) Marine plywood conforming to IS: 710 (DSR 9.126.1) 198 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.5 mm thick (DSR 9.127.1) 199 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. (DSR 9.127) 1.0 mm thick (DSR 9.127.2) 200 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge (DSR )(DSR 9.129) 201 Providing and fixing wire gauge shutters using stainless steel grade 304 wire gauge with wire of dia 0.5 mm and average width of aperture 1.4 mm in both directions for doors, windows and clerestory windows with necessary screws :30 mm thick shutters (DSR 9.134.2) With ISI marked stainless steel butt hinges of required size 9.134.2.2 Second class teak wood (DSR 9.134.2.2.1 ) 202 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. (DSR 9.135) With 2nd class teak wood beading 62X19 mm (DSR 9.135.1) 203 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 125 mm (DSR 9.165.1) 204 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 100mm (DSR 9.165.2) 205 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (DSR 9.165) 75 mm (DSR 9.165.3) 206 Providing and fixing 18mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. in partitions, boxes, shelves, racks and cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge (Note: Fittings to be paid separately). (DSR 9.166) 18 mm thick (DSR 9.166.1) 207 Providing and fixing 6mm thick both sides Pre-laminated cement bonded wood particle board as per IS : 15786:2008 of approved brand and shade with suitable full threaded steel screws etc. on the backing of racks, drawer, cupboard, kitchen cabinet under kitchen counter etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 9.167) 208 Providing and fixing cupboard shutter with 19mm thick one side decorative and other side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand including 2mm thick PVC edge banding tape with hot glue by edge bending machine etc. with auto closing spring loaded hinges (hydraulic type) etc. complete as per direction of Engineer-in-charge.(Payment of providing and fixing auto closing hinges shall be paid separately)(DSR )(DSR 9.168) 209 Providing and fixing 19mm thick both side balancing lamination factory pressed BWP grade marine ply as per IS 710 of approved brand boxes,shelves,racks,almirah,cupboard and drawer etc. including necessary nails,screws etc.complete as per direction of Engineer-in-charge.(DSR )(DSR 9.169) 210 Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-in-charge. (DSR 9.17) 200 mm (DSR 9.170.1) 211 Providing and fixing stainless steel soft closing spring hinges at 0 degree hinges (hydraulic type) of approved make/brand to cupboard shutters with full threaded steel screws including making necessary recess in board and finished etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 9.171) 212 Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.172) 213 Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensilbasket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately) (DSR )(DSR 9.173) 214 Providing and fixing 2mm thick 16 to 19mm wide PVC edge binding tape of approved quality for cupboard/wardrobe shutters including necessary synthetic resin hot pressed to edges on binding machine etc. complete as per directions of Engineer- in-charge. (DSR )(DSR 9.174) 215 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.1) 216 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. (DSR )(DSR 10.2) 217 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.10.1) 218 Fixing standard steel glazed doors, windows and ventilators in walls, including fixing of float glass panes with glazing clips and special metal-sash putty of approved make, or metal beading with screws, (only steel windows, glass panes cut to size and glazing clips or metal beading with screws, shall be supplied by department free of cost. (DSR 10.1) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.10.2) 219 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) (DSR 10.15.1) 220 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (DSR 10.15) Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately) (DSR 10.15.2) 221 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. (DSR 10.16) Electric resistance or induction butt welded tubes (DSR 10.16.3) 222 Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. (DSR )(DSR 10.17) 223 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. (DSR )(DSR 10.18) 224 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete (DSR 10.25.1) 225 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. (DSR 10.25) In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (DSR 10.25.2) 226 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) M.S. tube (DSR 10.26.1) 227 Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. (DSR 10.26) E.R.W. tubes (DSR 10.26.2) 228 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). (DSR )(DSR 10.28) 229 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. (DSR 10.29) Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides (DSR 10.29.2) 230 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (DSR 10.3) 4.0 mm thick glass panes (DSR 10.30.1) 231 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. (DSR )(DSR 10.31) 232 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:4 (1 cement : 4 coarse sand) (DSR 11.1.1) 233 Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: (DSR 11.1) 1:6 (1cement : 6 coarse sand) (DSR 11.1.2) 234 Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. (DSR )(DSR 11.2) 235 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (DSR 11.3) 40 mm thick with 20 mm nominal size stone aggregate (DSR 11.3.1) 236 Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. (DSR 11.6) 18 mm thick (DSR 11.6.1) 237 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete. (DSR )(DSR 11.7) 238 Providing and fixing glass strips in joints of terrazo/ cement concrete floors. (DSR ) 40 mm wide and 4 mm thick (DSR 11.13.1) 239 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Dark shade pigment using ordinary cement (DSR 11.20.3) 240 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). (DSR 11.2) Ordinary cement without any pigment (DSR 11.20.4) 241 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.1 Acid and alkali resistant tile (DSR 11.21.1.1) 242 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. (DSR 11.21) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 11.21.2 Acid and alkali resistant tile (DSR 11.21.2.1) 243 Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : (DSR 11.23) Udaipur green marble (DSR 11.23.5) 244 Extra for pre finished nosing to treads of steps of marble stone. (DSR )(DSR 11.24) 245 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. (DSR )(DSR 11.25) 246 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : (DSR 11.26) 25 mm thick (DSR 11.26.1) 247 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. (DSR )(DSR 11.27) 248 40 mm thick fine dressed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush. (DSR 11.28) Red sand stone (DSR 11.28.1) 249 Extra for Kota stone/ sand stone in treads of steps and risers using single length above normal size up to 2.00 metre. (DSR )(DSR 11.32) 250 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. (DSR )(DSR 11.37) 251 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. (DSR )(DSR 11.37A) 252 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. (DSR )(DSR 11.38) 253 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqmincluding grouting the joints with white cement and matching pigments etc., complete. (DSR 11.41) Size of Tile 600x600 mm (DSR 11.41.2) 254 Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer)with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.3 kg/sqm including grouting thejoints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only .Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. (DSR 11.41A) Double charge vitrified tile polished finish of size 11.41A.1 Size of Tile 600 x 600 mm (DSR 11.41A.1.1) 255 Providing and laying 500x500x40 mm thick Turf paver (Turfpave XD) on 150 mm thick sub grade of compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm thick jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all complete as per direction of Engineer-in-charge. (DSR )(DSR 11.45) 256 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. (DSR 11.48) Size of Tile 600x600 mm (DSR 11.48.2) 257 Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand)jointing with grey cement slurry @3.30 kg / sqm including grouting thejoints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only.Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400mm of all colours and shades.(DSR )(DSR 11.49A) 258 Deduct for not grouting the joints with white cement and matching pigment in the items of fixing of vitrified tiles. (DSR )(DSR 11.50) 259 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 75 mm (DSR 12.42.1.1) 260 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (DSR 12.42) Coupler 12.42.1 110 mm (DSR 12.42.1.2) 261 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : (DSR 12.45) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) (DSR 12.45.1) 262 Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated J or L hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. (DSR 12.47) 2 mm thick flat (DSR 12.47.2) 263 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spacedjoints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.52) 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. (DSR 12.52.4) 264 Providing and fixing tiled false ceiling of specifiedmaterials of size 595x595 mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. (DSR 12.58) 8 mm thick fully perforated calcium silicate board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process to give stable crystalline structure with minimum compressive strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm, having perforation of dia. 10 mm with minimum perforated area 18 % with non woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of 0.85, with 50 mm thick rockwool of 48 kg /cum backing. (DSR 12.58.1) 265 Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufactures specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: (DSR 12.59) 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. (DSR 12.59.1) 266 Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloyIS designation31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). (DSR 12.64) 0.56 mm, Aluminium troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. (DSR 12.64.1) 267 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Ridges plain (500- 600mm) (DSR 12.66.1) 268 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Crimp curve (DSR 12.66.5) 269 Providing and fixing of Pre-coated colour or mill finishAluminium Roofing Accessories in 0.71 mm thickness ,Alloy 31500 (IS designation) [Aluminium Alloy (AA) 3004 (ISO designation)]For color, coating shall be 5-7 microns epoxy primer on both sides of the sheet and polyester top coat 15-18 microns, using self drilling/tapping SS screws of size 6 x 50mm with 3mm thick EPDM seal and SS plain washer complete : (DSR 12.66) Precoated/mill finish aluminium Gutter (600 mm over all girth) (DSR 12.66.6) 270 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:4 (1 cement: 4 coarse sand) (DSR 13.4.1) 271 12 mm cement plaster of mix :CEMENT PLASTER (IN COARSE SAND) (DSR 13.4) 1:6 (1 cement: 6 coarse sand) (DSR 13.4.2) 272 12 mm cement plaster finished with a floating coat of neat cement of mix : (DSR 13.7) 1:4 (1 cement: 4 fine sand) (DSR 13.7.2) 273 6 mm cement plaster of mix : (DSR 13.16) 1:3 (1 cement : 3 fine sand) (DSR 13.16.1) 274 Neat cement punning. (DSR )(DSR 13.18) 275 Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. (DSR )(DSR 13.21) 276 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (DSR 13.41) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than50 gram/litre (DSR 13.41.1) 277 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.46) New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.46.1) 278 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: (DSR 13.47) New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) (DSR 13.47.1) 279 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm (DSR 13.48.1) 280 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture (DSR 13.48.2) 281 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : (DSR 13.48) Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture (DSR 13.48.3) 282 Finishing walls with ready mixed Premium acrylic emulsion paint (Company Depot Tinted) having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadewith silicon additives. (DSR 13.48A) New work (Two or more coats applied @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm. (DSR 13.48A.1) 283 Coal tarring two coats on new work using 0.16 Litre and 0.12 litre coal tar per sqm in the first coat and second coat respectively. (DSR )(DSR 13.59) 284 Lettering with black Japan paint of approved brand and manufacture (DSR )(DSR 13.71) 285 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. (DSR )(DSR 13.80) 286 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturerincluding applying additional coats wherever required to achieve even shade and colour(DSR 13.81) Old work (one or more coats) (DSR 13.81.1) 287 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) One coat (DSR 13.82.1) 288 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. (DSR 13.82) Two coats (DSR 13.82.2) 289 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) One coat (DSR 13.83.1) 290 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. (DSR 13.83) Two coats (DSR 13.83.2) 291 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre (DSR 13.85.1) 292 Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. (DSR 13.85) With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre (DSR 13.85.3) 293 White washing with lime to give an even shade : (DSR 13.87) Old work (two or more coats) (DSR 13.87.1) 294 White washing with lime to give an even shade : (DSR 13.87) Old work (one or more coats) (DSR 13.87.2) 295 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete (DSR )(DSR 13.88) 296 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. (DSR )(DSR 13.91) 297 Painting with oil type wood preservative of approved brand and manufacture: (DSR 13.97) Old work (one or more coats) (DSR 13.97.1) 298 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : (DSR 13.99) One or more coats on old work (DSR 13.99.1) 299 Re-lettering with black Japan paint of approved brand and manufacture. (DSR )(DSR 13.105) 300 Painting (one or more coats) with black Japan paint of approved brand and manufacture to give an even shade. (DSR )(DSR 13.106) 301 Finishing walls with textured exterior paint of required shade : (DSR 13.11) Old work (One or more coats) applied @ 1.82 ltr/10 sqm. (DSR 13.110.2) 302 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (DSR 13.111.1) 303 Finishing walls with Acrylic Smooth exterior paint of required shade : (DSR 13.111) Old work (One or more coat applied @ 0.90 ltr/10 sqm). (DSR 13.111.2) 304 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (Two or more coats applied @ 1.43 ltr/ 10 sqm) over existing cement paint surface (DSR 13.112.1) 305 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade (DSR 13.112) Old work (one or more coats applied @ 0.83 ltr/10 sqm). (DSR 13.112.2) 306 Varnishing with varnish of approved brand and manufacture: (DSR 13.113) One or more coats with copal varnish (DSR 13.113.1) 307 Melamine polishing on wood work (one or more coat). (DSR )(DSR 13.114) 308 Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below:1.The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2 layers without gap of time.) (DSR )(DSR 13.116) 309 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Door chowkhats (DSR 14.2.1) 310 Fixing chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15 x 10 x 10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.2) Window chowkhats (DSR 14.2.2) 311 Fixing chowkhat in existing opening in brick/ RCC wall with dash fasteners/Chemical fasteners of appropriate size (3 nos on each vertical member of door chowkhat and 2 nos on each vertical member of window chowkhats), including Cost of dash fasteners/ chemical fastener. (DSR )(DSR 14.3) 312 Making the opening in brick masonry including dismantling in floor or walls by cutting masonry and making good the damages to walls, flooring and jambs complete, to match existing surface i/c disposal of mulba/ rubbish to the nearest municipal dumping ground, all complete as per direction of Engineer-in-Charge. (DSR 14.4) For door/ window/ clerestory window (DSR 14.4.1) 313 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.5.1) 314 Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: (DSR 14.5) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.5.2) 315 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm) (DSR 14.7.1) 316 Renewing glass panes and refixing existing wooden fillets: (DSR 14.7) Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) (DSR 14.7.2) 317 Supplying and fixing new wooden fillets wherever necessary: (DSR 14.8) Hollock wood fillets (DSR 14.8.2) 318 Renewal of old putty of glass panes (length) (DSR )(DSR 14.9) 319 Refixing old glass panes with putty and nails (DSR )(DSR 14.10) 320 Fixing old glass panes with wooden fillets (excluding cost of fillets) (DSR )(DSR 14.11) 321 Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. (DSR )(DSR 14.12) 322 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. (DSR )(DSR 14.17) 323 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel 50 mm dia and below (DSR 14.22.1) 324 Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete. (DSR 14.22) Wheel above 50 mm dia (DSR 14.22.2) 325 Pumping out water caused by springs, tidal or river seepage, broken water mains or drains and the like. (DSR )(DSR 14.23) 326 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.1) 327 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Panelled or panelled & glazed shutters : 14.26.1 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.1.2) 328 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Superior class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.1) 329 Providing and fixing 25 mm thick shutters for cup board etc. : (DSR 14.26) Glazed shutters : 14.26.2 Ist class teak wood including nickel plated bright finished M.S. piano hinges with necessary screws. (DSR 14.26.2.2) 330 Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and clerestory windows. (DSR )(DSR 14.29) 331 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 125x70x4 mm (ordinary type) (DSR 14.40.1) 332 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 100x70x4 mm (ordinary type) (DSR 14.40.2) 333 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x65x4 mm (heavy type) (DSR 14.40.3) 334 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 75x40x2.5 mm (ordinary type) (DSR 14.40.4) 335 Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. (DSR 14.4) 50x40x2.5 mm (ordinary type) (DSR 14.40.5) 336 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromium plated brass screws, nuts, bolts and washers etc. complete. (DSR )(DSR 14.41) 337 Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre) (if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) (DSR )(DSR 14.75A) 338 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. (DSR )(DSR 14.76) 339 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm(DSR )(DSR 14.77) 340 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and otherdeposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine.(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. (DSR )(DSR 14.78) 341 Disconnecting damaged overhead/terrace PVC water storage tankof any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. (DSR )(DSR 14.79) 342 Providing & fixing White vitreous china water closet squatting pan (Indian type) along withS or P trap including dismantling of old WC seat and S or P trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. (DSR 14.8) Orissa pattern W.C Pan of size 580x440 mm (DSR 14.80.2) 343 Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 300 mm dia PVC pipe conforming BIS-12818 and making good the same etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 14.81) 344 DismantlingW.C.Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in-Charge. (DSR )(DSR 14.82) 345 Hacking of CC flooring including cleaning for surface etc. complete as per direction of the Engineer-in-Charge. (DSR )(DSR 14.83) 346 Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall (DSR )(DSR 14.84) 347 Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. (DSR )(DSR 14.85) 348 Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (DSR 15.2) Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) (DSR 15.2.2) 349 Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. (DSR )(DSR 15.3) 350 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (DSR 15.7) In cement mortar (DSR 15.7.4) 351 Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): (DSR 15.8) From brick work in cement mortar (DSR 15.8.3) 352 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area 3 sq. metres and below (DSR 15.12.1) 353 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : (DSR 15.12) Of area beyond 3 sq. metres (DSR 15.12.2) 354 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area 3 sq. metres and below (DSR 15.13.1) 355 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : (DSR 15.13) Of area beyond 3 sq. metres (DSR 15.13.2) 356 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) R.S. Joists (DSR 15.17.1) 357 Dismantling steel work in single sections including dismembering and stacking within 50 metres lead in: (DSR 15.17) Channels, angles, tees and flats (DSR 15.17.2) 358 Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. (DSR )(DSR 15.18) 359 Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.19) 360 Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead : (DSR )(DSR 15.24) 361 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) G.S. Sheet (DSR 15.28.1) 362 Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: (DSR 15.28) Asbestos Cement sheet (DSR 15.28.2) 363 Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. (DSR )(DSR 15.36) 364 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) 15 mm to 40 mm nominal bore (DSR 15.44.1) 365 Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : (DSR 15.44) Above 40 mm nominal bore (DSR 15.44.2) 366 Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: (DSR 15.45) Up to 150 mm diameter (DSR 15.45.1) 367 Taking out C.I. cover with frame from R.C.C. top slab of manholes of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.48) 368 Taking out C.I. cover with frame from R.C.C. top slab of inspection chambers of various sizes including demolishing of R.C.C. work manually/ by mechanical means and stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead as per direction of Engineer-in-charge. (DSR )(DSR 15.49) 369 Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. (DSR )(DSR 15.52) 370 Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres (DSR 15.53) Up to 150 mm diameter (DSR 15.53.1) 371 Dismantling of spindle fire hydrant including stacking of useful materials within 50 metres lead. (DSR )(DSR 15.54) 372 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. (DSR )(DSR 15.56) 373 Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge. (DSR )(DSR 15.57) 374 Demolishing R.C.C. work by mechanical means and stockpiling at designated locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking serviceable and unserviceable material separately including cutting reinforcement bars. (DSR )(DSR 15.58) 375 Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. (DSR )(DSR 15.60) 376 Brick edging in full brick width and half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres. (DSR 16.7) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.7.1) 377 Brick edging laid lengthwise with half brick depth including excavation, refilling and disposal of surplus earth lead upto 50 metres : (DSR 16.8) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 16.8.1) 378 Supplying at site : (DSR 16.15) R.C.C. Standards post/ struts/rails/ pales of mix 1:1.5:3 (1 cement : 1.5 coarsesand : 3 graded stone aggregate 12.5 mm nominal size) with wooden plugs or 6mm bar nibs wherever required as per direction of Engineer-in- charge (cost of earth works in excavation, concrete works in foundation to be paid separately). (DSR 16.15.1) 379 Supplying at site : (DSR 16.15) Welded steel wire fabric of required width having rectangular mesh painted with two or more coats of enamel paint of approved shade over a coat of primer (Priming & Painting to be paid for separately). (DSR 16.15.2) 380 Fencing with R.C.C. post placed at required distance, embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post one side only, provided with horizontal lines and two diagonals of barbed wire weighing 9.38 kg per 100 metres (minimum), between the two posts fitted and fixed with G.I. staples on wooden plugs or G.I. binding wire tied to 6 mm bar nibs fixed while casting the post (cost of R.C.C. posts, struts, earth work and concrete to be paid for separately) :- Payment to be made per metre cost of total length of barbed wire used. (DSR 16.17) With G.I. barbed wire (DSR 16.17.1) 381 Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. (DSR 16.18) With G.I. barbed wire (DSR 16.18.1) 382 Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete. (DSR )(DSR 16.19) 383 Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. (DSR 16.31) With medium setting bitumen emulsion 16.31.2 On bituminous surface @ 0.25kg/sqm (DSR 16.31.2.2) 384 2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone chippings of 13.2 mm and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately). (DSR 16.33) With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt (DSR 16.33.1) 385 Providing and laying seal coat of premixed fine aggregate ( passing 2.36 mm and retained on 180 micron sieve) with bitumen using 128 kg of bitumen of grade VG - 10 bitumen per cum of fine aggregate and 0.60 cum of fine aggregate per 100 sqm of road surface, including rolling and finishing with road roller all complete. (DSR )(DSR 16.40) 386 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete. (DSR )(DSR 16.42) 387 Extra for providing and mixing hardening compound of approved quality as per manufacturers specification in cement concrete. (DSR )(DSR 16.44) 388 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) (DSR )(DSR 16.45) 389 Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron Y shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) (DSR )(DSR 16.53) 390 Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.64) 391 Providing and fixing at or near ground level factory made RCC pavement slab of M-30 grade of size 450x450x50 mm, including reinforcement with 6 mm dia M.S. bars 4 nos on each side, including setting in position in footpath to the required level and line over a bed of 20 mm average thick cement mortar 1:5 (1 cement : 5 coarse sand), having joint thickness not more than 5mm except on curve, including filling of joints with same cement mortar and making grooves etc. complete as per direction of Engineer-in-charge. (DSR )(DSR 16.67) 392 Providing and laying 60mm thick faciory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge. (DSR )(DSR 16.68) 393 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). (DSR )(DSR 16.69) 394 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (DSR 16.7) Made of G.I. wire of dia 4 mm (DSR 16.70.1) 395 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). (DSR )(DSR 16.75) 396 Deduct for using of M-20 grade concrete instead of M-25 grade concrete in C.C. pavement. (DSR )(DSR 16.76) 397 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. (DSR 16.78) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 (DSR 16.78.2) 398 Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. (DSR )(DSR 16.83) 399 Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (Old CC paver blocks shall be supplied by the department free of cost). (DSR )(DSR 16.84) 400 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. (DSR )(DSR 16.89) 401 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. (DSR 16.91.1) 402 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed ofsand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. (DSR 16.91) 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. (DSR 16.91.2) 403 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (DSR 17.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests (DSR 17.1.1) 404 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (DSR 17.2) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.2.1) 405 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (DSR 17.3) W.C. pan with ISI marked white solid plastic seat and lid (DSR 17.3.1) 406 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps (DSR 17.7.3) 407 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.4) 408 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked (DSR 17.7.9) 409 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (DSR 17.7) Stainless Steel AISI-304(18/8) Wash basin 530x345 mm with single 15 mm C.P. brass pillar tap (DSR 17.7.11) 410 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a)White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (DSR )(DSR 17.7A) 411 Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required: (DSR 17.9) White glazed fire clay kitchen sink of size 600x450x 250 mm (DSR 17.9.1) 412 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink with drain board510x1040 mm bowl depth 200 mm (DSR 17.10.1.3) 413 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (DSR 17.1) Kitchen sink without drain board 17.10.2 610x510 mm bowl depth 200 mm (DSR 17.10.2.1) 414 Providing and fixing white vitreous china pedestal type (European type/ wash down type) water closet pan. (DSR )(DSR 17.15) 415 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. (DSR )(DSR 17.16A) 416 Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. (DSR 17.18) 10 litre capacity - White (DSR 17.18.1) 417 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete : (DSR 17.2) White solid plastic seat with lid (DSR 17.20.1) 418 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (DSR )(DSR 17.22A) 419 Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.(a) 15 mm nominal dia (DSR )(DSR 17.22B) 420 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. (DSR )(DSR 17.23) 421 Providing and fixing white vitreous china squatting plate urinal with integral rim longitudinal flush pipe. (DSR )(DSR 17.24) 422 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 630x450 mm (DSR 17.25.1) 423 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 550x400 mm (DSR 17.25.2) 424 Providing and fixing white vitreous china wash basin including making all connections but excluding the cost of fittings : (DSR 17.25) Flat back wash basin of size 450x300 mm (DSR 17.25.5) 425 Providing and fixing kitchen sink including making all connections excluding cost of fittings. (DSR 17.26) White glazed fire clay sink of size 600x450x250 mm (DSR 17.26.1) 426 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Semi rigid pipe 17.28.1 32 mm dia (DSR 17.28.1.1) 427 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (DSR 17.28) Flexible pipe 17.28.2 32 mm dia (DSR 17.28.2.1) 428 Providing and fixing 100 mm sand cast Iron grating for gully trap. (DSR )(DSR 17.29) 429 Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. (DSR )(DSR 17.30) 430 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (DSR )(DSR 17.31) 431 Providing and fixing 600x120x5 mm glass shelf with edges round off, supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. (DSR )(DSR 17.33) 432 Providing and fixing toilet paper holder : (DSR 17.34) C.P. brass (DSR 17.34.1) 433 Providing and fixing toilet paper holder : (DSR 17.34) Vitreous china (DSR 17.34.2) 434 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 31 mm dia of 79 mm length and 62mm breadth weighing not less than 45 gms (DSR 17.69.1) 435 Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. (DSR 17.69) Waste coupling 38 mm dia of 83 mm length and 77mm breadth, weighing not less than 60 gms (DSR 17.69.2) 436 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 31mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms (DSR 17.70.1) 437 Providing and fixing PTMT Bottle Trap for Wash basin and sink. (DSR 17.7) Bottle trap 38 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling, 77 mm breadth with 25 mm minimum water seal, weighing not less than 263 gms (DSR 17.70.2) 438 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. (DSR )(DSR 17.71) 439 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. (DSR )(DSR 17.72) 440 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms (DSR 17.73.1) 441 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (DSR 17.73) 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. (DSR 17.73.2) 442 Providing and fixing PTMT shelf 440 mm long, 124 mm width and 36 mm height of approved quality and colour, weighing not less than 300 gms. (DSR )(DSR 17.74) 443 Providing and fixing PTMT 15 mm Urinal spreader size 95x69x100 mm with 1/2 BSP thread and shapes, weighing not less than 60 gms. (DSR )(DSR 17.75) 444 Providing and fixing PTMT urinal cock of approved quality and colour. (DSR 17.76) 15 mm nominal bore, 80 mm long, 42 mm high and 30mm wide with BSP female threads weighing not less than 48 gms (DSR 17.76.1) 445 Providing and fixing M.S. holder bat clamp of approved design to sand cast iron/ cast iron (spun) pipes comprising of M.S. flat brackets made of 50x5 mm flat of specified shape, projecting 75 mm outside the wall surface and fixed on wall with 4nos, 6mm dia expansion hold fasteners, including drilling necessary holes in brick wall/ CC/ RCC surface and the cost of bolts etc. The pipes shall be fixed to the already fixed brackets with the help of 30 mm x1.6 mm galvanised M.S. flats of specified shape and of total length 420 mm and shall be fixed with M.S. nuts, bolts, & washers of size 25x6 mm, one bolts on each side of the pipe. (DSR 17.77) Total bracket length 580 mm of approved shape and design (for single 100 mm dia pipe) (DSR 17.77.1) 446 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. (DSR )(DSR 17.78) 447 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm having antibacterial /germs free ceramic surface, fixed with cartridge having debris catcher and hygiene seal. (DSR )(DSR 17.79) 448 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. (DSR )(DSR 17.80) 449 Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. (DSR )(DSR 17.81) 450 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 20 mm nominal dia Pipes (DSR 18.8.2) 451 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.(Concealed work, including cutting chases and making good the walls etc.) (DSR 18.8) 25 mm nominal dia Pipes (DSR 18.8.3) 452 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 15 mm nominal dia Pipes (DSR 18.9.1) 453 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 20 mm nominal dia Pipes (DSR 18.9.2) 454 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 25 mm nominal dia Pipes (DSR 18.9.3) 455 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 32 mm nominal dia Pipes (DSR 18.9.4) 456 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 40 mm nominal dia Pipes (DSR 18.9.5) 457 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 50 mm nominal dia Pipes (DSR 18.9.6) 458 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.(External work) (DSR 18.9) 80 mm nominal dia Pipes (DSR 18.9.8) 459 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work (DSR 18.12) 80 mm dia nominal bore (DSR 18.12.8) 460 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 25 to 40 mm nominal bore (DSR 18.13.1) 461 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (DSR 18.13) 50 to 80 mm nominal bore (DSR 18.13.2) 462 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). (DSR )(DSR 18.14) 463 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 15 mm nominal bore (DSR 18.15.1) 464 Providing and fixing brass bib cock of approved quality : (DSR 18.15) 20 mm nominal bore (DSR 18.15.2) 465 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 15 mm nominal bore (DSR 18.16.1) 466 Providing and fixing brass stop cock of approved quality : (DSR 18.16) 20 mm nominal bore (DSR 18.16.2) 467 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 25 mm nominal bore (DSR 18.17.1) 468 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 20 mm nominal bore (DSR 18.17.1A) 469 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 32 mm nominal bore. (DSR 18.17.2) 470 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 40 mm nominal bore (DSR 18.17.3) 471 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : (DSR 18.17) 80 mm nominal bore (DSR 18.17.6) 472 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Horizontal (DSR 18.19.1.1) 473 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 25 mm nominal bore 18.19.1 Vertical (DSR 18.19.1.2) 474 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Horizontal (DSR 18.19.2.1) 475 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 32 mm nominal bore 18.19.2 Vertical (DSR 18.19.2.2) 476 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Horizontal (DSR 18.19.3.1) 477 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 40 mm nominal bore 18.19.3 Vertical (DSR 18.19.3.2) 478 Providing and fixing gun metal non- return valve of approved quality (screwed end) : (DSR 18.19) 80 mm nominal bore 18.19.6 Vertical (DSR 18.19.6.2) 479 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 15 mm nominal bore (DSR 18.21.1.1) 480 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 30 cm length 18.21.1 20 mm nominal bore (DSR 18.21.1.2) 481 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 15 mm nominal bore (DSR 18.21.2.1) 482 Providing and fixing uplasticised PVC connection pipe with brass unions : (DSR 18.21) 45 cm length 18.21.2 20 mm nominal bore (DSR 18.21.2.2) 483 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 100 mm diameter (DSR 18.22.1) 484 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (DSR 18.22) 150 mm diameter (DSR 18.22.2) 485 Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (DSR 18.27) 100 mm dia pipe (DSR 18.27.1) 486 Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead : (DSR 18.28) 100 mm diameter pipe (DSR 18.28.1) 487 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 80 mm diameter pipe (DSR 18.30.1) 488 Providing flanged joints to double flanged C.I./ D.I. pipes and specials, including testing of joints : (DSR 18.3) 100 mm diameter pipe (DSR 18.30.2) 489 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class I (DSR 18.31.1.1) 490 Providing and fixing C.I. sluice valves (with cap) complete with bolts, nuts, rubber insertions etc. (the tail pieces if required will be paid separately) : (DSR 18.31) 100 mm diameter 18.31.1 Class II (DSR 18.31.1.2) 491 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (DSR )(DSR 18.48) 492 Providing and fixing PTMT Ball cock of approved quality, colour and make complete with Epoxy coated aluminium rod with L.P./ H.P.H.D. plastic ball. (DSR 18.62) 20 mm nominal bore, 120 mm long, weighing not less than 198 gms (DSR 18.62.2) 493 Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (DSR )(DSR 18.63) 494 Providing and fixing PTMT swivelling shower, 15 mm nominal bore, weighing not less than 40 gms (DSR )(DSR 18.64) 495 Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. (DSR )(DSR 18.65) 496 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. (DSR 18.84) 15 mm nominal bore (DSR 18.84.1) 497 Dismantling of old S.W. pipes including breaking of joints and bed concrete stacking of useful materials near the site within 50 m lead and disposal of unserviceable materials into municipal dumps : (DSR 19.5) 100 mm diameter (DSR 19.5.1) 498 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 150 mm dia. R.C.C. pipe (DSR 19.6.2) 499 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : (DSR 19.6) 300 mm dia. R.C.C. pipe (DSR 19.6.4) 500 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. (DSR 19.32) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 (DSR 19.32.1) 501 Constructing soak pit 1.20x1.20x1.20 m filled with brickbats including S.W. drain pipe 100 mm diameter and 1.20 m long complete as per standard design. (DSR )(DSR 19.33) 502 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.1.1) 503 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.1.2) 504 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For fixed portion 21.1.1 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.1.3) 505 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) (DSR 21.1.2.1) 506 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) (DSR 21.1.2.2) 507 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fastenersto be paid for separately) : (DSR 21.1) For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) 21.1.2 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) (DSR 21.1.2.3) 508 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm) (DSR 21.3.1) 509 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) (DSR 21.3.2) 510 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): (DSR 21.3) With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) (DSR 21.3.3) 511 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With stainless steel cover plate minimum 1.25 mm thickness (DSR 21.4.1) 512 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. (DSR 21.4) With brass cover plate minimum 1.25 mm thickness (DSR 21.4.2) 513 Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). (DSR )(DSR 21.5) 514 Providing and fixing 6 mm dia. G.I. level adjusting hangers (upto 1200mm length), fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40x3mm size 60 mm long and stainless steel expandable dash fastener of 12.5 mm dia and 50 mm long, complete as per direction of Engineer-in-charge. (DSR )(DSR 21.6) 515 Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. (DSR 21.8) Upto 5mm depth and 5 mm width (DSR 21.8.1) 516 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For fixed portion (DSR 21.9.1) 517 Extra for applying additional anodic coating AC 25 instead of AC 15 to aluminium extruded sections. (DSR 21.9) For shutters of doors, windows & ventilators (DSR 21.9.2) 518 Providing and fixing anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868. Minimum anodic coating of grade AC 15) sub frame work for windows and ventilators with extruded built up standard tubular sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia and size (Dash fastener to be paid for separately). (DSR )(DSR 21.14) 519 Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). (DSR )(DSR 21.17) 520 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). (DSR )(DSR 21.18) 521 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11601 (DSR 21.19) Upto 5 mm depth and 5 mm width (DSR 21.19.1) 522 Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete, complying to ASTM C920, DIN 18540-F & ISO 11602 (DSR 21.19) Upto 10 mm depth and 10 mm width (DSR 21.19.2) 523 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying :(a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.(The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.) (DSR )(DSR 22.5) 524 Providing and mixing integral crystalline admixture for water proofing treatment to RCC structures like basement raft, retaining walls, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc. at the time of transporting of concrete into the drum of the ready-mix truck ,using integral crystalline admixture @0.80% (minimum) to the weight of cement content per cubic meter of concrete) or higher as recommended by the manufacturers specification in reinforced cement concrete at site of work. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e. by reducing permeability of concrete by more than 90%, compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure. The crystalline admixture shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the Engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. (DSR )(DSR 22.22) 525 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. (DSR 23.1) All types of soil 23.1.1 300 mm dia (DSR 23.1.1.1) 526 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. (DSR 23.2) All types of soil 23.2.1 350 mm dia (DSR 23.2.1.2) 527 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. (DSR 23.3) 150 mm nominal size dia (DSR 23.3.2) 528 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (DSR 23.4) 150 mm nominal size dia (DSR 23.4.2) 529 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.5) 530 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.6) 531 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. (DSR )(DSR 23.7) 532 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. (DSR )(DSR 23.8) 533 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. (DSR )(DSR 23.12) 534 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: (DSR 23.13) 150 mm dia (DSR 23.13.2) 535 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. (DSR 23.14) 150 mm clamp (DSR 23.14.2) 536 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). (DSR 23.15) 150 mm dia (DSR 23.15.2) 537 Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment. (DSR )(DSR 25.1) 538 Providing and fixing factory madeKitchen Cabinet Shutter/Partition 20 mm nominal thickness of approved shade, quality and make, made from rigid foam sheets (Single extruded) having density 600 Kg/cum and laminated on both side by laminate Sheet/PVC foil lamination. The exposed edges shall be sealed with PVC edge beading of same shade and colour. The shutter shall be fire retardenthaving necessary screw holding capacity.Shutter shall be fixed to frame usingapproved hinges with necessary stainless steel screws, all complete as per direction of Engineer-in-charge. (DSR )(DSR 26.10) 539 Providing and fixing concealed hinge of approved quality for 19-20mm thick door with stainless steel screws complete : (DSR )(DSR 26.11) 540 Wiring for light point/ fan point/ exhaust fan point/ call bell point with1.5 sq mm frls pvc insulated copper conductor single core cable in surface /recessed medium class pvc conduit , with modular switch ,modular plate, suitable GI box and earething the pint with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (DSR E&M 1.10)Group A (DSR E&M 1.10.1) 541 Wiring for light/power plug with 2x4 sq. mm FRLS PVC insulatted copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. (DSR E&M 1.12) 542 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x2.5sq. Mm + 1x2.5 sq. mm eartrh wire (DSR E&M 1.14.2) 543 Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. (DSR E&M 1.14) 2x4sq. Mm + 1x4 sq. mm eartrh wire (DSR E&M 1.14.3) 544 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (DSR E&M 1.21) 25mm (DSR E&M 1.21.2) 545 Supplying and fixing 6way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240V, on Surface/recess,complete with tinned copper bus bar, heutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But with MCB/RCCB/Isolator) (DSR E&M 2022 2.3.1) 546 Supplying and fixing 5 amps to 32 amps rating,Single pole, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.10.1) 547 Supplying and fixing 63 amps, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.(DSR E&M 2022 2.12.2) 548 Supplying and fixing 63 A, four pole, 415V, isolator in the existing MCB DB Complete with connections, testing and commissioning etc. as required. (DSR E&M 2022 2.13.2) 549 Earthing with G.I earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (DSR E&M 2022 5.2) 550 Smoke Detector with built in LED, mounting base complete with all connection etc. (DSR E&M 2022 4102) 551 Manual call boxes of MS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4103) 552 Manual call boxes of ABS Type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. (DSR E&M 2022 4104) 553 Response indicator on surface/recessed MS Box having two LEDs metallic covers complete with all connections etc.(DSR E&M 2022 4105) 554 Fire alarm sounders (electronic) with facility to make announcement, mounted in M.S. Box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. (DSR E&M 2022 4106) 555 Fire alarm sounders (electronic) with facility to make announcement, mounted in A,B.S. Box with hinged cover plate & suitable for operation with amplifier l/c line matching ttransformer etc. (DSR E&M 2022 4107) 556 Talk back slave station in surface/recess suitable for operation on simplex mode complete with P.T.T. Knob & speaker/microphone enclosed in a M.S (16 SWG)/ABS.Box, break glass in front etc. (DSR E&M 2022 4108) 557 6 Zone fire alarm control panel as per IS: 2189 with backlit LCD (DSR E&M 2022 4110) 558 Cost of25 mm outer dia PVC/ABS Pipe with end caps including making air sampling operning of appropriate dia on appropriate interval. (DSR E&M 2022 4143) 559 Cost of fire survival armoured cable, fibre, fibre glass tape wrapped, ZH inner, outer sheath 2x1.5 sq. mm cable(DSR E&M 2022 4144) 560 Cost of fire alarm armoured FRLS cable 2 x 1.5 sqmm (DSR E&M 2022 4145) 561 Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required (DSR E&M 2022 19.1) 562 Concrete with 4cm gauge I class brick ballast, coarse sand (F.M. 1.8 to 2.5) and cement in proportion of 12:6:1 in foundations and under floors including supply of all materials, labour and tools and plants etc. required for proper completion. (CSI No.5.01 ) 563 Concrete work with 40 mm gauge brick ballast obtained from breaking brick bats (brick bats supplied by the department free of cost) in proportion of 12:6:1 as in CSI no. 5.01 including cost of all labour, materials, T&P etc required for proper completion of work. (CSI No. 5.20) 564 Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.18) 565 Brick work in Super structure with old dismantled bricks (supplied by department free of cost) and coarse sand of F.M. 1.8 to 2.5 mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (CSI No. 6.19) 566 S/F welded wire mesh size 75x25mm and rectangular made out of 10 SWG over M.S. angle frame with M.S. flat welded as required including cost of drilling holes, washer welding etc as required including cost of all material, labour and T&P etc. required for proper completion of work . exept cost of M.S angle and flat. (CSI No. 9.22) 567 Providing and laying SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. (CSI No. 27.29 c) 110 mm dia 568 Supply and Fixing of 3 blade wall fan of Havells platina 400 mm or equivalent including all material, T&P etc required for proper completion of work as approved by engineer in charge. (CSI No. 28.37) 569 Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge.(CSI No. 28.38) 570 Supply & fixing steel tubular pole 7 Metre long designated 410 SP-2 in 1:3:6 cement concrete foundation including excavation back filling etc. complete in all respect. 2018 PWD 603 571 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 641 572 Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130 mm and base plate 12mm thik) having 3mm thikness with Double arm bracket (1 Mtr length) on RCC foundationincluding the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. 2018 PWD 642 573 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131 574 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1131(A) 575 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 2018 PWD 1132 576 Same as in item no. 1132 but of 6..5 kg. capacity 2018 PWD 1132 (A) 577 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge 2018 PWD 1133 578 Supply and fixing of power plug with 15A/250 voltflushtype switch and 5 pin 15A/250V flush type universal socket in suitable M.S. box of 175mm x 100mm x 50mmsize with phenolic laminated bakelite sheet cover 3mm thick fixed with brass machine screw and cup washer. 2018 PWD 1139 579 Supply and fixing ofLED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. 2018 PWD 1413(A)CAT AA 580 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 Watt. Confirming to IP 66 protection complete in all respect. 2018 PWD 1421CAT AA 581 Supply and fixing ofLED Street light Fittinghaving die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66Protection complete in all respects.2018 PWD 1425(A)CAT AA 582 Supply and fixing of3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminium body with drive set . Confirming to IP 65 Protection complete in all respect. 2018 PWD 1441CAT AAA 583 Supply and fixing of 3 Watt to 6 Watt LED Spot/Spike light luminaire Confirming to IP 66 Protection complete in all respect. 2018 PWD 1441 (A) CAT AAA 584 Supply and fixing ofdecorative 8 to 16 Watt LEDbollard luminaire with driver set confirming to IP 65 protection complete in all respect. 2018 PWD 1442CAT AAA 585 Supply and fixing ofdecorative 40 to 45 Watt LED Post top indirect light luminaire having Pressure die cast aluminium body and Clear glass with driver set confirming to IP 65 and aboveprotection complete in all respect.2018 PWD 1443CAT AAA 586 Supply and fixing of 450mm size Exhaust fan of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 587 S/F of LED Bulb 9Watt bajaj or equivalent make as approved sample and make as per direction of Engineer in charge (NSI) 588 Supply and fixing of 200 mm Turbo ventilator Fan with ss Chimneycap & pipe of approved quality ISI mark (Bajaj/Havells/Usha/Crompton or equivalent make) complete with all respect as per sample approved by Engineer in charge including supply of all materials, labour and T&P etc requried for proper completion of the work as direction of E/I complete. (NSI ) 589 Providing and fixing 15 mm thick Industrial tiles size 600 x 600 mm to of Johnson Endura Meteor or approved make and colour using in different sizes (thickness to be specified by the manufacturer) conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete(NSI) 590 20-25 mm thick fine dressed Red sand stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement : 5 coarse sand) with joints finished flush.(NSI) 591 Providing/Laying 20-25 mm thick fine dressed Red sand stone flooring including supply of all materials, labour and T&P required for proper completion of work as perdirection of the Engineer-in charge.(NSI) 592 Providing and fixing prefab structure of size which does not require any structural steel frame at all heights of the existing building with following specifications: Manufactured by Epack polymers pvt ltd /Pronto panels Or Equivalent make.Walls: Outer & Inner walls made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The wall panels shall be connected to each other with Cam Locks @ 1.00 m C/C The walls shall be connected to the the base platform with 1mm thick channels & 100 to 150mm long dash fasteners. The walls & ceiling shall be connected to each other by 1mm thick flashing as per the manufacturer specifications. Any number of vertical partitions are to be provided in the structure as required at site & as per the directions of the E-in-C complete. All the inner / outer gaps, if any, are to be filled with silicon, rubber gasket or any material required complete & directions of the Engineer in charge.Ceiling: Made of 50 mm thick PUF insulated panels cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. The ceiling shall be extended from the wall on all sides by not less than 450mm & not more than 600mm with neccessary slopes in wall as required at the site & directions of the Engineer in charge complete. The outer edges of the roof shall be covered with the channel of the same material as of puff panel.Doors: Made out of 50 mm thick PUF insulated panels inner/outer side cladded with 0.5 mm thick PCGI sheet zinc coating 120 grams per sqm as per IS: 277. complete with providing & fixing all accessories like locks, SS hinges, SS Tower Bolts,SS handles of required size not more than 300mm.Windows: The frame work shall be of aluminium work (Powder coated aluminium (minimum thickness of powder coating 50 micron)) for doors, windows(Sliding/Openable as required with requisite handles, tower bolts,20mm dia SS curtain rod & any other fitting required ), ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be of thickness not less than 14gauge, smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing with 5.50mm thick glass / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. The outer surface shall have fly proof stainless steel grade 304 wire gauge, using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete .Strengthing of door, window, ventilators & any other opening : Any opening provided will have the framework strengthened with 1mm thick MS Plate on all sides all complete & directions of the Engineer in charge.Measurements: Only the floor area of the pre fab outer structure will be measured for payment purpose.Conditions Rates include all lifts, leads, depths, material, labour, scaffolding, all heights for location, carriage, wastage, tools and plants and other all inputs for execution of the item. The colour of the panels for walls & ceiling should be got approved from the E-in-C prior to start of manufacturing of the structure. The Structure requires approx five partitions in the two structures besides two outer walls . Note: The zinc sheet of the puff panels can either be plain/corrugated on both sides or one side plain & one side corrugated upto any pitch in horizontal / verticals per the drawings & requirement at site. 593 Supply,Installation, testing & commissioning Battery 12 V 7 AH Exide or equivalent make for above fire alarm system. Complete as per direction of the Engineer-in charge. 594 Supply,Installation, testing & commissioning Response Indicator Agni Suraksha or equivalent make. Complete as per direction of the Engineer-in charge. 595 Supply,Installation, testing & commissioning Camera (3 MP) colour W Audio IP Dome Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 596 Supply,Installation, testing & commissioning Camera (2 MP) IP Dome Falcon series Secureye or equivalent Indian make ,Lens-3.6mm. Complete as per direction of the Engineer-in charge. 597 Supply,Installation, testing & commissioning NVR 8 channelSecureye or equivalent Indian make, with 4TBHDD Hard Disk. Complete as per direction of the Engineer-in charge. 598 Supply,Installation, testing & commissioning Connector D link or equivalent make Complete as per direction of the Engineer-in charge. 599 Supply,Installation, testing & commissioning 8 Port POE Switch Secureye or equivalent Indian make Complete as per direction of the Engineer-in charge. 600 Supply,Installation, testing & commissioning Cable (CAT6) D link or equivalent make Complete as per direction of the Engineer-in charge. 601 Servicing of Air Conditioner (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.30) 602 Servicing of Air Conditioner and filling of GAS (For Window/Split) by aurthorised service center complete in all respect including all labour and T&P. (CSI No. 20.31) 603 Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver setcomplete in all respect. 1401 PWD CAT AA 604 Supply and fixing of recess/ Surface/ Pendent mounting round 10 to 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. 1402 PWD CAT AA 605 Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect.1406 PWD CAT AA 606 P/F of 30 W orevo make or equivalent make LED light 30 Watt over Hoarding frame along boundary wall of MD DVVNL Campus, 220 KV S/S Sikandra , Agra with necessary materials , labour, T&P etc required for proper completion of the work as per direction of Engineer in charge. (NSI) 607 Providing and fixing of 20 W Philips make or equivalent make LED Tube light 20 Watt with necessary materials labour, T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI) 608 S/F of 07 Watt LED bulb Syska or other equivalent make including cost of labour, T&P etc required for proper completion of the work (NSI) 609 Supply and fixing of vertical blinds with hanging/sliding rod of aluminium (vista or equivalent make), vertical cord for operation of blinds, L-type hooks, screws, gullies etc. including all T&P, labour etc required for proper completion of the work in all respect. (NSI) 610 Printing name and designation of occupants and other information on residence block/office building including preparation of the base with best quality synthetic enamel paint as directed by E/I including cost of all materials, labour and T&P etc. required for proper completion of work. (NSI) 611 Providing and fixing of Name plate Acrylic/Glow sign Sheet per mm thick without letter as per approved shade and design as per direction of Engineer in charge (NSI) 612 Providing and Pasting of Name plate letter cutting words laser machine without name plate including cost of necessary all fittings such as nut, screws, labour T&P etc requried for proper completion of the work as per direction of Engineer in charge (NSI)
Contract Date: Apr 23, 2026 Contract Value : 21.94 Lakh
Government Departments No of Bidders 3
Uttar Pradesh View Result →
40.
Rural Development #10171950 Technical Bid
Tender For Ktw Parsoda Tq.Vaijapur Dist.Chhatrapati Sambhajinagar - Excavation in all kinds of soil including boulders upto 0.60 m. diameter (0.113 cum.) for canal, seating of embankment, filter drains/ catch water drains etc. and placing excavated stuff neatly in dump area or for formation of service road/embenkment as directed including cost of all materials, machinery. labour, dressing bed and sides to required level and profile etc. with 15m. lead and 6 m. lift. 2 Item no.2: Excavation in hard murum including boulders upto 0.60 m. diameter (0.113 cum.) for canal, seating of embankment, filter drains/ catch water drains etc. and placing excavated stuff neatly in dump area or formation of service road as directed including cost of all machinery, labour, dressing bed and sides to required level and profile etc. with 15 m lead and 6 m. lift. 3 Item no.3: Excavation in soft rock without blasting including boulders upto 0.60 m. diameter (0.113 cum.) for canal, seating of embankment, filter drains/ catch water drains etc. and placing excavated stuff neatly in dump area or for formation of service road as directed including cost of all machinery, labour, dressing bed and sides to required level and profile etc. with 15 m lead and 6 m. lift. 4 Item no.4: Providing and fixing in position TMT-FE-500 bar reinforcement steel of various diameter for R. C. C. pile, caps, footing, foundation, slabs, beams, columns, canopies, staircase, newels, chajjas, lintel, pardies, copings, fins, arches etc as per detailed design, drawing and schedules. Including, bending, hooking the bars, binding with wires or tack welding and supporting as required etc. complete as directed. 5 Item no.5: Providing and laying in situ cement concrete of grade M. 150 (40 MSA) of trap/granite /gneiss/quartzite graded metal for PCC with or without surface reainforcement/ RCC concreting requiring heavy of special type of shuttering for works of gallery, sluice, spillway crest, spillway downstream face, energy dissipating structurs, intake structurs, training walls, piers, abutment etc. with cement concrete mixer with shuttering and scaffolding, curing with an initial lead of 1 km. and all lifts etc, completed as directed. 6 Item no.6: Back filling upto ground level behind the ground level behind the canal structures etc. completed (without royalty) with suitable material of approved quality in layers not exceeding 20 cm. without disturbing the structeur etc. completed 7 Item no.7: Straight Needle K. T. weir Gate-Manufacturing with QAP & fabrication of K. T. weir needle gates- straight type size 2.15 x 0.50 M-94 Kg. weight as per relevent Indian Standard with all material, Mild steel confirming to IS 2062, Rubber seal confirming to IS 4623 & Welding electrodes AWS E6013 for general weld joints. It includes all materials, labour charges, machinery charges, 1 km lead charges of transportation, including loading and unloading charges of Gate parts at Site, Inspection & Quality control charges, Sand blasting, Painting with one coat of Zinc rich primer on dry film to give total dry film thickness 70 +/-5 micron and 2 coats of sloventless coal tar epoxy paint applied to give munimum dry film thickness of 150+/-5 micron per coat as per IS 14177 8 Item no.8 Providing and fixing canal information board of size 1.20 x 0.75 m. prepared on 16 mm guage M. S. sheet with angle iron frame of size 35 x 35 x 3 mm with cross bracing of size 25 x 25 x 3 mm including painting with one coat of zinc cromite storing primer and two coats each of green/white back ground and back side grey store enameled bonded with red retro reflective sheet Engineering grade, border/letters/ numeral arrows coated with non peal able crystal clear protective transparent coat retaining 100% reflection including two angle iron post of size 50 x 50 x 5 mm of 3.65 m long inflated at bottom drilled on top and painted in white and black bonds of 30 cm with four numbers high strength of G.I. bolts and nuts of size 10 mm dia and 20 mm long sheet and angle iron post in one piece without joints including all taxes, conveying, fixing in ground with cement in M-15 block of size 60 x 60 x 75 cm as directed
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
41.
Educational and Research Institute #10140471 Price Bid
Supply Of Library Books Supply Of Library Bookssupply Of Library Books , Library Books , Introduction To Database Management System P.K. Yadav , Database Management Systemp.K. Yadav , Concepts Of Database System P.K. Yadav , Software Project Managementrajiv Chopra , Software Testing Rajiv Chopra , Software Testing And Quality Assurance Rajiv Chopra , An Integrated Approach To Software Engineering Rajiv Chopra , Internet Of Things (Iot) Rajiv Chopra , Object Oriented Software Engineeringrajiv Chopra , Introduction To Microprocessor Rajiv Chopra , Requrements And Estimation Techniques Rajiv Chopra , Fundamentals Of Computing Rajiv Chopra & Rishbh Anand , An Introduction To Automata Theory & Formal Languages Adesh K. Pandey , Introd. To Automata Theory & Formal Lang.Adesh K. Pandey , Fundamentals Of Compiler Designadesh K. Pandey , Concepts Of Complier Designadesh K. Pandey , Concepts Of E-Commerceadesh K. Pandey , Internet Fundamentalsadesh K. Pandey , Network Security & Administrationadesh K. Pandey , Internet & Web Designingadesh K. Pandey &Er.Neha Dutta , Introduction To E-Commerce & Erpadesh K. Pandey , A Textbook Of Compiler Designadesh K. Pandey , Elements Of Compiler Designadesh K. Pandey , Theory Of Automata And Computationadesh K. Pandey , Theory Of Computationadesh K. Pandey , Fundamentals Of Electronics Commerce Adesh K. Pandey , Internet Programming Using Javapandey & Pandey , Fundamentals Of Computer Programming In Cs.K.Jha , System Analysis & Designs.K.Jha , Programming In Cs.K.Jha , Pc Organization S.K.Chauhan , Pc Upgrading Maintenance & Trouble Shooting Guide , Neural Network & Fuzzy Logicvinoth Kumar And R.Saravana Kr. , Soft Computingk.Vinoth Kumar , Fundamentals Of Soft Computingk.Vinoth Kumar , Computer Concepts & Programming In Camit Kumar Mishra , Basic Computer Engineeringamit Kumar Mishra , Introduction To Computer Systemamit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , A Textbook Of Computer Architecture Amit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , Computer System And Programming In C Amit Kumar Mishra , Computer Architecture & Organizationamit Kumar Mishra , Information Security And Cyber Laws Amit Kumar Mishra , Advanced Computer Architecture Amit Kumar Mishra , Computer Architecture Amit Kumar Mishra , Computer Programming Amit Kumar Mishra , Fundamentals Of Computer And Programming Amit Kumar Mishra , Software Engineeringbali And Bali , Fundamentals Of Software Engineeringbali And Bali , Thinking In C++ Rajesh Kocher & Sunil K. Pandey , Learn Autocadrajesh Kocher & Sunil K. Pandey , Fundamentals Of Computer Programming And Itsunil K. Pandey& V.K. Jain , Object Oriented Programing With C ++ Sunil K. Pandey& Rajesh Kochher , Programming Language Nitin Upadhyay , The Design & Analysis Of Algorithmsnitin Upadhyay , Data Structures And Algorithms Using C Nitin Upadhyay , Question Bank In Computer Sciencenitin Upadhyay, Pankaj Sharma , Computer Networks Dr. Sanjay Sharma , Elements Of Computer Networks Dr. Sanjay Sharma , Computer Networks Dr. Sanjay Sharma , A Course In Computer Networksdr. Sanjay Sharma , Introduction To Computer Networks Dr. Sanjay Sharma , Computer Networks-I Dr. Sanjay Sharma , Advanced Computer Networksdr. Sanjay Sharma , Computer Networks-Ii Dr. Sanjay Sharma , Principles Of Computer Networks Dr. Sanjay Sharma , Digital Logic Design Dr. Sanjay Sharma , A Textbook Of Computer Network Dr. Sanjay Sharma , Fundamentals Of Computer Network Dr. Sanjay Sharma , Introduction To Web Technologypankaj Sharma , Fundamentals Of Web Technologypankaj Sharma , Artificial Intelligencepankaj Sharma , Working With Artificial Intelligencepankaj Sharma , Web Engineering Pankaj Sharma , Manet And High Speed Networkspankaj Sharma , Computer Organization Pankaj Sharma , Computer Architecture & Organizationpankaj Sharma , System Programmingpankaj Sharma , Expert System Pankaj Sharma , Information Security & Cyber Lawspankaj Sharma , System Programming & System Admin. Pankaj Sharma , Rapid Application Devlop.Using Visual Basic & Visual C++Pankaj Sharma , Parallel Algorithms Pankaj Sharma , Pattern Recognitionpankaj Sharma , Web Developmentpankaj Sharma , Information Storage & Managementpankaj Sharma , Web Engineering Pankaj Sharma , System Administration Pankaj Sharma , Information Security Pankaj Sharma , Cloud Computing Pankaj Sharma , Introduction To Web Engineering Pankaj Sharma , Web Administration Pankaj Sharma , Dot Net Framework With C# Programming Dr. Lalit Arora , Object Oriented System With C++ Dr. Lalit Arora , Object Oriented System With Javadr. Lalit Arora , Internet & Javadr. Lalit Arora , C# Using .Net Frameworkdr. Lalit Arora , Java Programming & Web Site Designdr. Lalit Arora , Object Oriented Techniques Java Dr. Lalit Arora , Object Oriented Programing Using C ++Dr. Lalit Arora , It Skills And Technology Dr. Lalit Arora , Concept Of Programming And Oopsdr. Lalit Arora, Dr. Raj Kumar & Dr. Anjali , Computer Organization & Architecture Dr. Lalit Arora, Dr. Raj Kumar & Dr. Anjali , Computer Graphicsudit Agarwal , Introduction To Computer Graphicsudit Agarwal , Data Structures Using C Udit Agarwal , Data Structures Udit Agarwal , Software Engineeringudit Agarwal , Distributed Systems Udit Agarwal , Distributed Computing Udit Agarwal , Data Mining And Data Warehousingudit Agarwal , Computer Graphics And Multimedia Udit Agarwal , Programming For Problem Solving Udit Agarwal , Operating Systemvijay Shukla , Multimedia System, Technology & Communication Sujata Pandey , Data Mining & Data Ware Housing , Network Programmingkadambri Agarwal , Programming Languages Kadambri Agarwal , Network Technologykadambri Agarwal , System Network Administration Kadambri Agarwal , Graph Theoryk.Patrai , Discrete Structures & Graph Theoryk.Patrai , Mobile Computingvishnu Sharma , Advances Mobile Computingvishnu Sharma , “Operating System Internal And Design Principles”, N William Stallings, Pearson Education,7 Th Editio , “Operating System, Principles & Design”,Pal Chaudhury, Philearning, Firstedition , Operating System Concepts”Abraham Siberschatz Galvin, Gagne, Wileypublishers,9 Thedition, , “Operating Systems”,Harvey M. Deiteland Paul J.Deitel, David , Programming With Cbyron Gottfried. Schaum Series -Tmgh , Programming And Problem Solving Using Cisrd Group, Lucknow Tata Mc-Grawhill, Newdelhi , Let Us Cyashavent Kanethar Bpb Publication, 2005, New Delhi , Introduction To Data Structures With Applications.Trembley And Sorenson Tata Mc-Grawhill, Newdelhi , Fundamentals Of Data Structures In C Horowitz , Sahni Anderson- Freed University Press, Hyderabad , Introduction To Data Structuresbhagat Singh Tmgh, New Delhi , Data Structures And Algorithmsg.A. Vijayalakshmi Pai Tmgh, New Delhi , “Computer System Architecture”,M.Morris Mano, Prentice –Hall Of India Pvt Limited,Revised Third Edition. , “Computer Organization And Architecture Designing For Performance”,William Stallings, Pearson Publications, Eighth Edition. , “Computer Organization And Design:The Hardware/Software Interface”, David A. Patterson And John L.Hennessey, Morgan Kauffman / Elsevier, Fifth Edition, 2014. , “Computer Architecture And Organization”,John P. Hayes, Tata Mc Graw Hill, Thirdedition , Computer Organization And Embedded Systems”,Carl Hamacher, Zvonko Vranesic, Safwat Zaky And Naraig Manjikian, Sixth Edition, Tata Mcgraw Hill, 2012 , “The Internet Book”, Prentice Hall. “Douglas E. Comer” , “Web Development And Design Foundations With Html5”, Pearson “Terry Felke-Morris” , “Html & Css:The Complete Reference”, Tata Mcgras-Hil “Thomas A. Powell, Fritz Schneider” , “Java Script: The Complete Reference”, Tata Mcgras-Hil “Thomas Powell, Fritz Schneider” , “Beginning Php6, Apache, Mysql, Web Development”, Wrox Publications “Timothy Boronczyk, Elizabeth Naramore, Jason Gerner, Yann Le Scouarnec, Jeremy Stolz, Michael K. Glass” , ,“Programming With Java”, Tata Mc-Graw Hill, Newdelhi E. Balagurusamy “ , “Java - The Complete Reference”, Tata Mc Graw Hill, New Delhi “Herbert Schildt “, , “Java 2,J2se1.4 Complete”, Bpb Publications , “Database System Concepts”,Mc Graw Hill Education. Seventh Edition. “Abraham Silberschatz, Henry F.Forth, S.Sudarshan”, , “Murach’S Mysql”, Mike Murach & Associates, Inc. 3Rd Edition. “Joel Murach”, , “The Complete Reference Mysql” “Vikram Vaswami”, , “Mysql Developers Library”, Addison Wesley (4Th Edition) “Paul Dubois”, , Introduction To Computing And Problem Solving Using Python E.Balagurusamy , Learning Python Programmingjeffrey Elkner, Allan B. Downey, Chris Meyer , Taming Python By Programmingjeeva Jose , Python Programming , Mcgraw Hilleducation(India) Pvt. Ltd. 2018 5. Learn And Practiceashok Namdev Kamthane And Amit Ashok Kamthanepython Programming Swapnil S , A Course In Electrical Technologyj.B Gupta , A Course In Electrical Technology-Ij.B Gupta , A Course In Electrical Technology-Iij.B Gupta , A Course In Electrical Technology-Iiij.B Gupta , Generation & Economic Considerationsj.B Gupta , A Course In Electrical Powerj.B Gupta , A Course In Power Systems J.B Gupta , Theory & Performance Of Electrical Machinej.B Gupta , Utilization Of Electric Power & Electric Tractionj.B Gupta , Utilization Of Electrical Energy And Traction J.B.Gupta, R. Manglik, R. Manglik , Switchgear & Protectionj.B Gupta , A Course In Electrical Installation Estimating & Costingj.B Gupta , Fundamentals Of Electrical & Electronics Engineering J.B Gupta , Transmission & Distribution Of Electrical Powerj.B Gupta , Basic Electrical Engineeringj.B Gupta , Basic Electricity J.B Gupta , Electrical Measurements & Measuring Instrumentsj.B Gupta , Electrical Machines-Ij.B Gupta , Electrical Machine - Iij.B Gupta , An Integrated Course In Electrical Engineering J.B Gupta , Explanation/Solutions To An Integrated Course In Electrical Engineering J.B Gupta , An Integrated Course In Electrical Engineering Volume I J.B Gupta , An Integrated Course In Electrical Engineering Volume Ii J.B Gupta , Question Bank In Electrical Engineeringj.B Gupta , Question Bank In Electrical Engineering Volume I J.B Gupta , Question Bank In Electrical Engineering Volume Ii J.B Gupta , A Text Book Of Electrical Engineeringj.B Gupta , Electrical Science J.B Gupta , Electromechanical Energy Conversionj.B Gupta , Electromechanical Energy Conversion- Ij.B Gupta , Electromechanical Energy Conversion- Iij.B Gupta , Electrical Machines (Ac, Dc Machine)J.B Gupta , A Text Book Of Electrical Technologyj.B Gupta , Electrical Machines & Automatic Controlj.B Gupta & Hasan , Elements Of Power Systems J.B Gupta , Power System Analysis J.B Gupta , Fundamentals Of Switchgear & Protectionj.B Gupta , Electrical Engineering Materials & Semiconductor Devices J.B Gupta , Basic Electrical & Electronics Engineering J.B Gupta , Electrical Machines-Ij.B Gupta , Electrical Machines-Ii J.B Gupta , Electrical Technologyj.B Gupta , Basic Electrical Engineeringj.B Gupta , Fundamentals Of Electrical Engineering J.B Gupta , Elements Of Electrical Engineering J.B Gupta , Basic Electrical Engineering J.B Gupta , A Textbook Of Electrical Science J.B Gupta , A Textbook Of Electrical Engineering Rajeev Manglik , Power System & Protectionn.K.Datta , Theory & Performance Of Electrical Machine Design Dr. N.K.Datta , Principles Of Electrical Machine Designr.K. Agarwal , Electrical Engineering Materialsrakesh Dogra , Electrical Engineering Drawing-Isurjit Singh , Electrical Engineering Drawing-Iisurjit Singh , Electrical Measurements & Measuring Instrumentsm.L.Anand , Basic Electrical Engineeringtarlok Singh , Installation Commissioning & Maintain. Of Elect. Equip.Tarlok Singh , Electrical Measurement & Measuring Instrumentstarlok Singh , Elements Of Electrical & Electronics Engineering Tarlok Singh , Utilization Of Electric Energytarlok Singh , Electrical Machine-Itarlok Singh , Electrical Machine-Iitarlok Singh , Electrical Power-Iitarlok Singh , Fundamentals Of Electrical Engineering Tarlok Singh , Electrical Science Tarlok Singh , Transmission & Distributiontarlok Singh , Modern Electric Traction Tarlok Singh , Energy Managementdr. Sanjeev Singh, Umesh Rathore , Basic Instrumentation System & Programmable Logic Controllerumesh Rathore , Industrial Instrumentationumesh Rathore , Programmable Logic Controller And Microcontrollers Umesh Rathore , A Textbook Of Electrical Workshop Practices Umesh Rathore, Naresh Kumar Sharma , A Textbook Of Energy Science & Engineering Umesh Rathore , Fundamentals Of Managementdr. R.C.Bhatia , Sub-Station Engineering Design, Concepts & Computer Applications Er. R.S.Dahiya , An Introduction To Electric Traction Sachidananda Mallik & Rupali G. Nazar , Fundamentals Of Managementrenu Rana , Special Electrical Machines Simmi P Burman , High Voltage Engineering Simmi P Burman & Nikita Gupta , Electrical Engineering Laboratory Practice P. Tiwari & S. Sairola , Ehv-Ac, Hvdc Transmission And Distribution Engineering Sanjay Kumar Sharma , Basic System Analysissyed Hasan Saeed & Faizan Arif Khan , Power Quality Simmi P. Burman & Bipin Singh , Scada And Energy Management System Er. Tanuj Kumar Bisht , Computer Aided Design Of Electrical Machines V.K. Maurya, Ritu Raj Jallan, Shasya Shukla , A Textbook Of Power System Operation And Control K. Nisha , Electromagnetic Field Theory Syed Hasan Saeed & Faizan Arif Khan , Installation Maintenance And Repair Of Electrical Machines And Equipments Madhvi Gupta , Electrical Engnineering Design, Drawing & Estimation Madhvi Gupta, Ankit Agarwal , Control Systems S.P. Meher , Fundamentals Of Smart Grid Technology Bharat Modi, Anu Prakash & Yogesh Kumar , Electric Vehicle Dr. Nitesh Tiwari , Ssc-Je-Question Bank In Electrical Engineering J.B.Gupta , Ace Academy Gate 2024 Ace Publication , Gate/Ese/Psus Electrical Handbook Ace Publication , Ace Academy Ese Vol 1And Vol 2 Ace Publication , Yct Electrical Engineering Je-Vol And Vol 2 Yct Publications , Yct Electrical Engineering Ae-Vol And Vol 2 Yct Publications , Basic Electrical Engineering Vol 1S Chand Publication,B L Theraja , Ac & Dc Machine Vol 2 S Chand Publication,B L Theraja , Transmission And Distribution Utilisation S Chand Publication,B L Theraja , Electronics Devices And Circuits S Chand Publication,B L Theraja , Power Electronics Khanna Publications,Dr. Ps Bhimbra , Fundamentals Of Electrical Circuits Mc Graw Hill,Charles K.Alexander , Objective Electrical Technology V.K.Mehta,Rohit Mehta , Principles Of Power System V.K.Mehta,Rohit Mehta , Principles Of Electrical Machines V.K.Mehta,Rohit Mehta , Control Of Machines New Age International , Sk Bhattacharya , Linear Integrated Circuits New Age International , Sk Bhattacharya , Programmable Logic Controllerpearson, John.R.Hackworth , Principles Of Electromagnetics Oxford,Sadiku & Kulkarni , A Course In Electrical & Electronics Measurements And Instrumentation Dhanpat Raj & Co ,A K Sawhney , Fundamentals Of Digital Circuits Phi, A.Anand Kumar , Power Electronics Devices Circuits And Applicationpearson, Muhammad H. Rashid , Electrical Power System C.L.Wadhwa, New Age International , Modern Power System Analysis Mc Graw Hill,D.P.Kothari , Electrical Machinery Khanna Publications,Dr. Ps Bhimbra , Generalized Theory Of Electrical Machines Khanna Publications,Dr. Ps Bhimbra , Electronics Devices And Circuits S.Salivahanan,Mc Graw Hill , Micro Controller Principles And Applications Ajit Pal,Eastern Economy Edition , Power Plant Engineering Mc Graw Hill,P K Nag , Power System Engineering Lp, R.K.Rajput , Non Conventional Energy G D Rai,Khanna Publication , Basic Electrical And Electronics Engineering Mc Graw Hill,D.P.Kothari , Repair And Maintenance Bpb Publications,Shashi Bhushan Sinha , Electrical Applications Haynes , Electronic Devices And Circuitsj.B.Gupta , Basic Electrical And Electronics Engineeringj.B.Gupta , Linear Integrated Circuitsj.B.Gupta , Fundamentals Of Analog Electronicsj.B.Gupta , Basic Electronics J.B.Gupta , Electrical & Electronics Engineering J.B.Gupta , A Textbook Of Basic Electronics J.B.Gupta, Rajeev Manglik, Rohit Manglik , Analog Devices And Circuits J.B.Gupta , Fundamentals Of Electronics Devices & Circuits J.B.Gupta , Electronic Devices & Circuits Dr. Sanjay Sharma , Analog & Digital Electronicsdr. Sanjay Sharma , Signal & Systemsdr. Sanjay Sharma , Digital Signal Processing Dr. Sanjay Sharma , Electronics Circuits Dr. Sanjay Sharma , Digital Electronics Dr. Sanjay Sharma , Digital Communications Dr. Sanjay Sharma , Fundamentals Of Electronic Devicesdr. Sanjay Sharma , Digital Communication Dr. Sanjay Sharma , Digital Signal Processing Dr. Sanjay Sharma , Principle Of Digital Signal Processingdr. Sanjay Sharma , Analog & Digital Communication Dr. Sanjay Sharma , Signal & System Dr. Sanjay Sharma , Fundamentals Of Communication Engineering Dr. Sanjay Sharma , Communication Engineeringdr. Sanjay Sharma , Digital Electronics And Logic Design Dr. Sanjay Sharma , Digital Circuits & Systems Dr. Sanjay Sharma , Wireless Communication Systems Dr. Sanjay Sharma , Electronic Circuits Dr. Sanjay Sharma , Digital Electronics & Design Aspects Dr. Sanjay Sharma , Electronic Devices Dr. Sanjay Sharma , Signals & Systems Dr. Sanjay Sharma , Digital Design Dr. Sanjay Sharma , Analog And Digital Electronics Dr. Sanjay Sharma , A Textbook Of Electronics Engineering Dr. Sanjay Sharma , Fundamentals Of Digital Electronics Dr. Sanjay Sharma , Fundamentals Of Digital Image Processing Dr. Sanjay Sharma , Digital Image Processing Dr. Sanjay Sharma , Wireless Communication System Dr. Sanjay Sharma , Mobile Computing Dr. Sanjay Sharma , Switching Theory And Logic Design Dr. Sanjay Sharma , Essentials Of Computer Networks Dr. Sanjay Sharma , Data And Computer Communications Dr. Sanjay Sharma , Fundamentals Of Switching Theory & Logic Design Dr. Sanjay Sharma , Essentials Of Analog Communication Dr. Sanjay Sharma , Data Communication And Computer Networks Dr. Sanjay Sharma , A Textbook Of Data Communication And Networks Dr. Sanjay Sharma , Essentials Of Wireless Communication Dr. Sanjay Sharma , Fundamentals Of Electronics Engineering Dr. Sanjay Sharma , Wireless Communicationsdr. Sanjay Sharma , Electronic Devices & Circuits Dr. Sanjay Sharma , Fundamentals Of Digital Signal Processing Dr. Sanjay Sharma , Fundamentals Of Analog Communication Dr. Sanjay Sharma , A Textbook Of Signals & Systems Dr. Sanjay Sharma , Solid State Devices & Circuits Dr. Sanjay Sharma , Electronics-I Dr. Sanjay Sharma , Signal Processing And Linear Systems Dr. Sanjay Sharma , Emerging Domain In Electronics Engineering Dr. Sanjay Sharma , Circuits & Systemsk.M.Soni , Circuit Analysis And Synthesis K.M.Soni , Advanced Control Systemsk.M.Soni , Network Analysis & Systhesisk.M.Soni , Network Analysisk.M.Soni , Network Theory K.M.Soni , Fundamentals Of Network Analysis & Synthesis K.M.Soni , Basic System Analysisk.M.Soni , Signals And Systems K.M.Soni , Digital Electronicsb.R.Gupta And V.Singhal , Consumer Electronicsb.R.Gupta , Power Electronicsb.R.Gupta And V.Singhal , Introduction To Electric Drivesb.R.Gupta And V.Singhal , Question Bank Electronics & Communicationengineeringb.R.Gupta And V.Singhal , Fundamentals Of Electric Drives And Control B.R.Gupta And V.Singhal , Industrial Electronics & Instrumentationsunil Kumar , Optical Fiber Communicationsapna Katiyar , Satellite Communicationsapna Katiyar , Advanced Communication Systemsapna Katiyar , Electronic Switchingsapna Katiyar , Introduction To Optical Communicationsapna Katiyar , Telecommunication Networkssapna Katiyar , Fundamentals Of Optical Fiber Communicationsapna Katiyar , A Textbook Of Optical Fiber Communication Systems Sapna Katiyar , Introduction To Satellite Communcation Sapna Katiyar , Tv And Satellite Communications Sapna Katiyar , Vlsi (Technology,Design & Basics Of Microelectronics)Sapna Katiyar , 8051 Microcontroller & Embedded Systemsampath K. Venkatesh , Digital Circuit System Using Vhdlneelu Chaudhary And Shipra Gupta , Digital Logic & Design Pratima Manhas And Shaveta Thakral , Digital Electronicspratima Manhas And Shaveta Thakral , Vlsi Design Pratima Manhas & Shaveta Thakral , Introduction To Microprocessors & Interfacingaashutosh Gupta , Electromagnetic Fields & Wavesr.Gowri , Wireless Communicationaman Kundra And Amrita Sandhu , Trouble Shooting & Maintenance Of Elect. Equipmentsk.Sudeep Singh , Fundamentals Of Television & Radar Engineering K.K Sharma , Fundamentals Of Radar, Sonar & Navigation Engineering K.K Sharma , Fundamentals Of Data Communicationk.K Sharma , Digital & Analog Communicationk.K Sharma , Microwave & Radar Engineeringk.K Sharma , Antenna & Wave Propagation A.K.Gautam , Principle Of Communication Engineering A.K.Gautam , Communication System-Ia.K.Gautam , Microwave Engineering A.K.Gautam , Control System Hasan Saeed , Digital & Analog Communicationbrijesh Verma , Mobile Communicationbrijesh Verma , Telemetry & Data Transmissionr.N.Baral , Electronics Devices & Circuits-I M.L.Anand , Bio-Medical Signal Processing Rakesh Kumar , Medical Electronics O.N. Pandey & Rakesh Kr. , Instrumentation And Process Control O.N. Pandey , Electromagnetic Field Theory Parul Dawar , Digital Circuit And Systems Shipra Gupta , Vlsi Designc.P Verma , Introduction To Vlsi Circuits & Systems Deepak Garg , Vlsi Technology Deepak Garg , Fundamentals Of Vlsi Design Deepak Garg , Basics Of Vlsi Design With Vhdl Deepak Garg , Microprocessor & Interfacingn. Marriwala , Embedded System Design N. Marriwala & Ritu Khullar , Fundamentals Of Radar & Navigation Sachin Gupta , Optical Communication Sachin Gupta , Microwave And Radar Engineeringravi Garg & Ankaj Gupta , Antenna And Wave Propagation Prashant Pandey , Digital Electronics Preeti Sehrawat , Electronic Circuits M. Elangovan , Electromagnetics And Antennas H. Singh , Optoelectronics & Optical Communication Satyajit Das , Control Systems Engineering Dr. S. Panda, S. Padhy & S.R. Das , Microcontroller And Embedded Systems Ankaj Gupta , Microprocessors And Microcontrollers Ankaj Gupta , Fundamentals Of Microprocessors And Embedded Systems Ankaj Gupta , Microprocessors Shweta Goyal & Swati Gargust , Industrial Electronics And Control Of Drives Shweta Goyal & Swati Gargust , Engineering Economics And Industrial Management Dr. R.K. Singal & Er. Rishi Singal , Microwave & Radar Engineering Er. Rajesh Dhiman , Embedded Systems Anurag Arora , Wireless Sensor Networks Sunil Gupta & Dr. Harsh K. Verma , Probability, Random Variables And Stochastic Methods Himanshu Chaurasiya & Dr. K.M. Soni , Relational Database Management System Pooja Sharma & D.S. Sehrawat , Semiconductor Devices And Circuits C.S. Murlidharan Sharma , Industrial Power Electronics Partha K. Ganguly , An Insight To Matlab & Simulink Dr. Shailender Gupta & Bharat Bhushan , Fundamentals Of Optical Communication & Networks Shila Ghosh, Somali Sikder , Digital Image Processing Ketki Kshirsagar, Rajeshree Shinde , Embedded System & Microcontroller Manish Verma & K.B. Singh , Electronic Design Automation & Logic Synthesissarita Chauhan , Artificial Intelligence For Engineers Malvika Gupta, Medha Malik , Principles Of Electronics Dr. S.K. Bhattacharya , Machine Learning Dr. Himanshu Sharma , Strength Of Materials R.S.Khurmi S.Chand & Company Ltd, New Delhi , Strength Of Materials S.Ramamirtham Dhanpat Rai , Engineering Mechanics R K Bansal Laxmi Publications Pvt.Ltd. , Building Materials P.C.Varghese Prentice-Hall Of India (P) Ltd., I Edition , Building Construction Dr. B.C. Punmia Laxmi Publications (P)Ltd New Delhi. , Building Construction S.C.Rangwala Charotar Publishing House, Vii Edition , Surveying Volume I Punmia.B.C. Ashok K.Jain & Arun K. Jain Lami Publications Private Limited, 16Th Edition , Surveying Volume Ii & Iii Punmia.B.C, Ashok Jain & Arun K. Jain Lami, Publications Private Limited., 15 Th Edition, , Fundamentals Of Surveying S. K. Roy Phi Learning Private Limited , Building Planning And Drawing Dr.N.Kumaraswamy Charotor Publishing House , Building Planning And Construction G. Vaidhyanathan, I. Kulasekaran, G. Sathish Kumar , A Guide To Civil Engineering Drawing V.R.Thothathri , Theory Of Structures S. Ramamrutham Dhanpat Rai Publications, New Delhi , Theory Of Structures B.C. Punmia, Ashok Jain & Arun Jain Laxmi Publications , Analysis Of Structures V.N. Vazirani & M.M. Ratwani , Fluid Mechanics R.K. Bansal Lakshmi Publications , Hydraulics,Fluid Mechanics And Hydraulics Machines S. Ramamirtham Dhanpat Rai & Sons, New Delhi , Hydraulics, Fluid Mechanics And Hydraulics Machines K.R. Arora Standard Publishers & Distributors, New Delhi , Highway Engineering S.K.Khanna And C.E.G Justo Nem Chand And Bros, Roorkee. , Highway Engineering Rangwala Charotor Publishing House Pvt. Ltd , A Text Book Of Transportation Engineering S P Chandola S Chand & Company Ltd , Bridge Engineering Rangawala Charotor Publishing House , Reinforced Concrete Design N Krishnaraju New Age International Publications, 2012 , Is 456-2000 , Steel Structures Hand Book Sp16 , Limit State Design Of Reinforced Concrete B C Punmia Laxmi Publications,2007 , Design Of R C C And Structural Elements ( Rcc Vol I) S S Bhavikatti, New Age International Publications, 2011 , Environmental Engineering B C Punmia Lami Publications, 2010 , Waste Water Engineering B C Punmia ,Laxmi Publications, 2010 , Environmental Engineering A.Kamala,D.L.Kanthraotata Mcgraw Hill Publishing Company Ltd.,New Delhi , Concrete Technologym.S. Shetty S.Chand & Company Pvt. Ltd. New Delhi. , Soil Mechanics And Foundation Engineering B C Punmia Laxmi Publications (P) Ltd., 2005 , Civil Engineering Drawings.C. Rangwala Charotor Publishing House , Construction Management Sanga Reddy. S Kumaran Publications, Coimbatore , Steel Structures Dr.Subramaniam , Town Planning S.C. Rangwala , Principles And Practice Of Town And Country Planninglewis B. Keeble Estates Gazette, University Of Michigan, 2010 , Estimating & Costing L.N.Dutta Dhanpat Rai & Sons , Estimating & Costingrangawala ,Charotor Publishing , Quantity Surveying & Valuation N.A.Shaw Khanna Publishers; , Civil Engineering Competitionsbooks R.Agor Khanna Publishers; , Civil Engineering (Objective Type) P Jaya Rami Reddy , Laxmi Publications , Reinforced Concrete Design S.Unnikrishna Pilla & Devadas Menon, Mc Graw Hill Publications , Limit State Design Of Steel Structures S K Duggal , Mc Graw Hill Publications , Basic And Applied Soil Mechanics , Gopal Ranjan & A S R Rao, New Age International Publications , Fluid Mechanics And Fluid Power Engineering Dr. D.S Kumar , Basics Of Mechanical Engineering Dr. D.S Kumar , Mechanical Engineering (Objectives) Dr. D.S Kumar , Refrigration And Air Conditioner Dr. D.S Kumar , Total Quality Management Dr.K.C.Arora , Engineering Drawing ,Ps Gill , Textbook Of Machine Drawing,Ps Gill , Geomatric Dimensioning And Tolerancing , Ps Gill , Computer Aided Drafting Using Autocad , Ps Gill , Learning Autocad , Ps Gill , Auto Cad 2D Design Fundamentals , Ps Gill , Auto Cad 3D Models Fundamentals Ps Gill , Operation Research ,Ap Verma , Textbook Of Industrial Management , Ap Verma & N.Mohan , Industrial Engineering And Management , Ap Verma , Stem Tables Rk Singal , Manufacturing Practices (Workshop Practices) Rk Singal , Engineering Metrology And Instrumention , Rk Rajput , Strength Of Materials , Rk Rajput , Textbook Of Material Science , Callister , Workshop Technology , Virendra Narula , Manufacturing Process , Virendra Narula , An Intoduction To Nc And Cnc , S.Vishal , Computer Aided Manufacturing, S.Vishal , Automobile Engineering , Km Moeed , Manufacturing Process I Sandy Khippal , Manufacturing Process Ii Sandy Khippal , Principals Of Powder Meatallurgy , Ps Gill , Inspection And Quality Control, Ap Verma , Automation Of Robotics, Khushdeep Goyal , Industrial Automation And Robotics, Khushdeep Goyal , Cnc Machines And Automation , Khushdeep Goyal , Production Planing And Control , Rk Singal , Theroy Of Machines , Rk Singal , Data Book For Designing Machine Elements , Arunkumar , Entreprenurship Development, Ranbirsingh , Unconventional Manufacturing Process , Rahul Jain , Mechanics Of Solids , Timoshenko , Engineering Mechanics , Timoshenko , Mechanics Of Solids , Egor P Popov , Fluid Mechanics And Fluid Power Engineering, Frank M White , Matlab For Dummies , John Mueller , Machine Learning For Dummies , John Mueller , Thermodynamics , Cengel , The Functional Aspects Of Communication Skills, Dr. P. Prasad , Professional Communication, Dr. P. Prasad , Universal English (In The Twenty-First Century) Dr. P. Prasad , Effectual Communication Skills , Bhupender Kaur , Engineering Physics, Dr. Abhijit Nayak , Essentials Of Physicsdr. Rakesh Dogra , Engineering Physics (Aicte) Dr. Rakesh Dogra , Applied Physics- Imanpreet Singh , Applied Physics -Iimanpreet Singh , Laser Systems & Applications, Dr. Rajesh Mishra , Engineering Physics-I, Dr. Rajesh Mishra , Fundamentals Of Polymer Science & Technology, Anshu Srivastava & Shakun Srivastava , Nuclear Science, Chanchal Garg , Petrochemicals, Anjana Srivastava , Impact Of Science Technology On Society, Ishwar Singh , Introduction To Bioscience , Dr. O.N. Pandey , Introduction To Bioscience Sweety Israni , A Textbook Of Nanoscience , Dr. Rakesh Kumar & Dr. Kamala Pati Tiwary , Professional Communicationdr. Raavee Tripathi , Technical Writing , Dr. O.N. Pandey , Engineering Economics , Dr. O.N. Pandey , Numerical Analysis Dr. Surbhi Gupta & Dr. Abhilasha Sharma , Business Environment ,Anita Sengar , Numerical Methods ,Girish Nayyar , Human Values And Professional Ethics , Smriti Srivastava , Discrete Mathematical Structures , Adesh K. Pandey & Rakesh Dube , Effective Technical Communication , Dr. Bharti Kukerja, Dr. Anupama Jain , Human Behaviour , Dr. Amit Jain , Organisational Behaviour , Er. Ishwar Singh, Dr. Bratpal Singh , Universal Human Values And Professional Ethics , Dr. Ritu Soryan , Soft Skills , Dr. Ritu Soryan , Communication Skills, Dr. Ritu Soryan , Constitution Of India , Richa Chaudhary, Arunima Mishra, Imran Khan , Concise Engineering Physics , Dr. Shiva Kant Pathak , Discrete Mathematicsanjana Gupta , Discrete Structures, Adesh K. Pandey , Discrete Structure, Kalika Patrai , Applied Mathematics- I, Dr. Hari Arora , Applied Mathematics- Ii, Anita Sachdeva & Hari Arora , Applied Mathematics- I, Dr. J.S.Bindra And K.S.Gill , Applied Mathematics- Ii, Dr. J.S.Bindra And K.S.Gill , Applied Mathematics- Iii, Dr. J.S.Bindra And K.S.Gill , Elements Of Engineering Mathematics- I Dr. V.P. Mishra , Elements Of Engineering Mathematics- Ii, Mishra & Mishra , Elements Of Engineering Mathematics- Iii, Mishra & Mishra , Engineering Mathematics-I , Mishra & Mishra , Question Bank In Engineering Mathematics , Mishra & Mishra , A Textbook Of Applied Mathematics-I, Dr. Hari Arora , A Textbook Of Applied Mathematics-Ii , Dr. Hari Arora , A Textbook Of Applied Mathematics-Iii , Dr. Hari Arora , A Textbook Of Applied Mathematics-Iv , Dr. Hari Arora , A Textbook Of Engineering Mathematics-Ii , Dr. Hari Arora , A Textbook Of Engineering Mathematics-I (Calculus & Linear Algebra) , Dr. Hari Arora , Applied Mathematics-Ii (Previous Year Papers) Dr. Hari Arora , Numerical Methods And Optimization Dr. Hari Arora , Probability & Statistics Dr. Hari Arora , Differential Equations And Complex Analysis Dr. Hari Arora , Numerical Methods For Engineers And Scientists Dr. Hari Arora , Engineering Mathematics-Iii Amit Gupta , Mathematics (Cbse) (Class - Ix)Upadhyay & Upadhyay , Mathematics (Cbse) (Class - X) Upadhyay & Upadhyay , Mathematics (Cbse) (Class - Xi) Upadhyay & Upadhyay , Mathematics For Mechanical Engineering (A Solution Manual) Salman Hussien Omran, Laith Jaffer Habeeb , A Textbook Of Finite Element Method , Pushpam Kumar Sinha , Engineering Chemistry , Dr. Sunita Rattan , Engineering Chemistry With Experiments , Dr. Sunita Rattan , Comprehensive Engineering Chemistry, Dr. Sunita Rattan , Experiments In Applied Chemistry , Dr. Sunita Rattan , Theory & Practical Of Engineering Chemistry, Dr. Sunita Rattan , A Textbook Of Engineering Chemistry , Dr. Sunita Rattan , Engineering Chemistry (With Experiments) , Dr. Sunita Rattan , Applied Chemistry- I, Dr. Raman Rani Mittal , Applied Chemistry- Ii, Dr. Raman Rani Mittal , Engineering Chemistry, Dr. Renu Gupta , New Course Engineering Chemistry, Dr. S.K. Bhasin , New Course Engineering Chemistry , Dr. S.K. Bhasin , Realm Of Space Science , Rajeev Garg , A Textbook Of Engineering Chemistry , Dr. Sunita Rattan , A Textbook Of Engineering Chemistry , Dr. Rajshree Khare , Applied Physics (Theory & Experiments) , Ritika Sorot Chauhan, Kavindar Tiwari , Applied Chemistry (Theory & Experiments) , Dr. Babita Bhardwaj , Junior English Revised , Haydn Richards => Limited
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 5
43.
Educational and Research Institute #10088358 Price Bid
Supply Of Books , Library Books , Machine Design, T. V. Sundararajamoorthy & N. Shanmuga ,Anuradha Publications, Kumbakonam. , Revised Edition June-2003 , Industrial Motor Control., Stephen Herman ,Cengage Learning , 6Th Edition , Electrical Technology, Edward Hughes ,Addision– Wesley International Student Edition , Latest Edition , Mysql, Paul Dubois ,Addison Wesley , 4Th Edition , No Sql Distilled, Pramod J. Sadalage Martin Fowler ,Addison Wesley , 1St Edition Or Latest Reprint , American Society Of Metals – Hand Book – Volume 4 ( Forming), American Society Of Metals,American Society Of Metals , Latest Edition , Programmable Controller Theory And Implementation, L.A.Bryan E.A.Bryan ,An Industrial Text Company Publication , Latest Edition , Biomedical Instrumentation, M. Arumugam ,Anuradha Publications, Chennai , Latest Edition , Android Apps For Absolute Beginners, Jackson ,Apress , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Arasan Ganesan Institute Of Technology , 1993 , Home Refrigeration And Air Conditioning, Audels, Theo. ,Audel & Co. Publisher, New York. - 1998 , 199 Edn.49 , Remote Sensing And Geographical Information System, M.Anji Reddy ,B.S Publications , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , 1997 , Exploring Programmable Logic Controller With Applications, Pradeep Kumar Srivastava ,Bpb Publication , Latest Edition , The Complete Pc Upgrade And Maintenance, Mark Minasi ,Bpb Publication , Latest Edition , Advanced Mobile Repairing, Pandit Sanjib ,Bpb Publication , First Edition 2010 , Modern Vcd Video Cd Player Introduction, Servicing And Troubleshooting, Manohar Lotia & Pradeep Nair ,Bpb Publication , Latest Edition , Explosing Programmable Logic Controllers With Application., Pradeep Kumar Srivastava. ,Bpb Publication , Latest Edition , Let Us C, Yeswanth Kanetkar ,Bpb Publication , 16Th Edition , Programmable Logic Controller, Pradeep Kumar & Srivashtava ,Bpb Publication , Latest Edition , Modern Computer Hardware Course, Manahar Lotai, Pradeep Niar, Payal Lotia ,Bpb Publication , Second Revised Edition 2011 , Inside Autocad, D. Raker And H. Rice,Bpb Publication , Latest Edition , Text Book Of Environmental Science And Technology, M.Anji Reddi ,Bs Publications , Latest Edition , Book 1 - General Aspect Of Energy Management And Energy Audit,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , Book 3 - Energy Efficiency In Electrical Utilities,,Bureau Of Energy Efficiency, New Delhi , Second- 2005 , National Building Code Of India – 2005,,,Bureau Of Indian Standards, New Delhi , Latest Edition , Total Quality Management, Oakiand.J.S.,Butterworth Heinemann Ltd. Oxford , 1989 , The Art Of Electronics, Paul Horowitz ,Cambridge University , 2Nd Edition Press , Performance And Design Of Ac Machine, M.G.Say ,Cbs Publisher & Distributor , Latest Edition , A Text Book Of Soil Mechanics, Dr S B Sehgal ,Cbs Publisher & Distributors , Latest Edition , Building Repair And Maintenance Management, P.S.Gahlot ,Cbs Publisher & Distributors (P) Ltd , Latest Edition , Learning Material Development Project – Nitttr,,Cd Programme On Gps And Gis. , Latest Edition , Introduction To Programmable Logic Controllers, Gary Dunning ,Cengagelearning India Pvt Ltd , Latest Edition , Building Materials, S.C.Rangwala ,Charotar Publishing House , 1982 , Building Construction, S.C.Rangwala ,Charotar Publishing House , Latest Edition , Mechanics Of Structures (Vol Ii), S.B. Junnarkar ,Charotar Publishing House , 22Nd Edition , Highway Engineering, Rangwala ,Charotar Publishing House , 2010 , Railway Engineering, Rangwala ,Charotar Publishing House , 2010 , Bridge Engineering, Rangwala ,Charotar Publishing House , 2009 , Estimating & Costing, Rangawala ,Charotar Publishing House , Latest Edition , Construction Of Structures And Management Of Works, Rangwala.S.C ,Charotar Publishing House , Latest Edition , Machine Design, Pandya & Shah ,Charotar Publishing House , 1995 , Principle Of Geographical Information Systems For Land Resources Assessment, Burrough P.A. (2000) ,Clarendon Press, Oxford. , Latest Edition , Technician’S Guide To Programmable Logic Controllers, Richard A. Cox ,Delmer , Sixth Edition 2011 , Principles Of The Manufacturing Of Composite Materials , Suong V Hoa, ,Des Tech Publication. Inc , Latest Edition , Strength Of Materials, S.Ramamirtham ,Dhanpat Rai , 2003 , A Course In Electrical And Electronics Measurements And Instrumentation., A.K. Sawhney Puneet Sawhney ,Dhanpat Rai , Latest Edition , Estimating & Costing, L.N.Dutta ,Dhanpat Rai , Latest Edition , Thermal Engineering., B.K. Sarkar. ,Dhanpat Rai , 3Rd Edition , Internal Combustion Engines, M.L.Mathur & R.P.Sharma ,Dhanpat Rai , Latest Edition , Mechanical Draughtsmanship,G.L. Tamta, Dhanpat Rai ,Dhanpat Rai , Latest Edition , Engineering Drawing, D.N. Ghose ,Dhanpat Rai , Latest Edition , A Course In Electrical Power, Soni & Gupta ,Dhanpat Rai , Latest Edition , Hydraulics,Fluid Mechanics And Hydraulics Machines, S. Ramamirtham ,Dhanpat Rai , Latest Edition , Modern Electric Traction, H Partab ,Dhanpat Rai , Latest Edition , Mechanical Measurements, A.K.Sawhney-Dhanpat Rai & Sons ,Dhanpat Rai , Latest Edition , Electronic Measurements And Instrumentation, Sanjay Talbar & Akhilesh Upadhyaya ,Dhanpat Rai , 2004 , Electrical And Electronic Measurements And Instrumentation, A.K.Sawheney ,Dhanpat Rai , 1993 , A Coursein Electricalpower, Soni, Gupta ,Dhanpat Rai , Latest Edition , Strength Of Materials, S. Ramamrutham ,Dhanpat Rai , 15 Edn 2004 , Course In Electrical Machine Design, A.K.Sawhney ,Dhanpat Rai , Latest Edition , Electrical Technology, B.L.Theraja ,Division Of Nirja Constructions And Dev Co.(P) Ltd , 1994 , Design Data Book, Psg College Of Technology ,Dpv Printers, Coimbatore , Latest Edition , Suftware Testing Concepts And Tools, Nageshwara Rao Pusulri ,Dreamteach , First Edition , Automotive Mechanics, Joseph Heitner ,East West Press (P) Ltd, New Delhi , Latest Edition , Renewableenergy Sources , Twidell, J.W. And Weir, ,Efn Spon Ltd , Latest Edition , Vehicle And Engine Technology, Heinz Heisler ,Elbs , Latest Edition , Programmable Logic Controller, W. Bolton ,Elsevier India Pvt Ltd , Iv Edition , Principles And Practice Of Town And Country Planning, Lewis B. Keeble ,Estates Gazette, University Of Michigan , 2010 , A Text Book On Building Services, R.Udyakumar ,Eswar Press, Chennai , Latest Edition , Fluid Mechanics, K.L.Kumar ,Eurasia Publshing House - New Delhi , Latest Edition , A Text Book Of Machine Design., R.S. Khurmi & J.K.Gupta ,Eurosia Publishing House - New Delhi ,Edn. 18 , Mechanical Measureme Control, R.V. Jalgaonk ,Everes T Publishing House, Pune , Latest Edition , The Cell Phone Handbook, P.J. Stetz And Penelope Stetz ,Findtech Ltd , Second Edition , Pc Repair And Maintenance, Joel Rosenthal ,Fire Wall Media, New Delhi , First Edition 2007 Reprint :2012 , Software Engineering, Bharat Bhusan Agarwal, Sumit Prakash Tayal ,Fire Wall Media, New Delhi , Second Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , The Laptop Repair Workbook: An Introduction To Troubleshooting And Repairing Laptop Computers, Morris Rosenthal ,Foner Books , First Edition 2008 , Multimedia Technology & Applications,, David Hillman ,Galgotia Publications Pvt Ltd. , Latest Reprint , Repair And Seismic Strengthening Of Buildings - Guidelines, Is:13935 - 2002,,Guidelines, Is:13935 , 2002 , Automotive Mechanics, William H.Crouse And Donald .L. Anglin ,Hill Publishing Company Ltd, New Delhi , Latest Edition , Die Design Fundamentals, Paquin.J.R,,Industrial Press Inc , Latest Edition , Digital And Analog Communication System, B.P.Lathi .Zhi Ding ,International Oxford University Press , 4Th Edition , Mysql Bible, Steve Suehring ,John Wiley & Sons , 2002, Latest Reprint , Modern Production / Operations Management, E.S. Buffa And R.K. Sarin ,John Wiley & Sons , Latest Edition , Remote Sensing And Image Interpretation, Lillesand, T.M. & Kiefer R.W. (1998) ,John Wiley & Sons , Latest Edition , Ground Water Hydrology, David Keith Todd ,John Wiley & Sons , Latest Edition , Digital Communications, Simon Haykin ,John Wiley India Edition , Latest Edition , Cad/Cam, Mikell P.Groover ,Jr.Prentice Hall Of India Pvt., Ltd. , Latest Edition , A Course In Electrical Power, J.B. Gupta ,Kaison Publishing House , Reprint 2004 , Civil Estimating, Costing And Valuation,,Kalson Publishing House , Latest Edition , Machine Drawing, P.S. Gill ,Katsan Publishing House , Latest Edition , Analysis Of Structures – Vol 1, Vazirani & Ratwani ,Khanna Publishers , Latest Edition , Quantity Surveying & Valuation, N.A.Shaw ,Khanna Publishers , Latest Edition , Water Supply And Sanitary Engineering, S.K.Garg ,Khanna Publishers , Latest Edition , Hydrology And Water Resources Engineering, Santhosh Kumar Gar ,Khanna Publishers , Latest Edition , Fluid Mechanics, Prof. S. Nagarathinam - ,Khanna Publishers , Latest Edition , Workshop Technology ,Raghuwanshi,Khanna Publishers , Latest Edition , Production Technology,Nai Sarak ,Khanna Publishers ,Edn. Xii , Thermal Engineering, P.Lballaney ,Khanna Publishers , 24Th Edition , Production Technology, Jain & Gupta ,Khanna Publishers , Latest Edition , Automobile Engineering, G.B.S.Narang ,Khanna Publishers , Latest Edition , Thermal Engineering, P.L Ballaney,Khanna Publishers , 24Th Edition , Applied Thermodynamics, Domkundwar And C.Pkothandaraman ,Khanna Publishers ,2Nd Edition , Non Conventional Energy Sources, G.D. Rai,Khanna Publishers , 1999 , Industrial Engineering And Management, O.P. Khanna ,Khanna Publishers , Latest Edition , Refrigeration And Air Conditioning, P.L . Ballaney ,Khanna Publishers , Latest Edition , Electric Circuit Theory, Dr.M.Arumugam Dr.N.Premkumaran ,Khanna Publishers , Latest Edition , Electrical Power, S.L Uppal ,Khanna Publishers , Latest Edition , Electrical Wiring, Estimating And Costing, Dr.S.L.Uppal G.C. Garg ,Khanna Publishers , Sixth- 2011 , Electric Circuit Theory, M. Arumugam, N. Premkumaran ,Khanna Publishers , 1997 , Power Electronics, P.S.Bimbhra, ,Khanna Publishers , 5Th Edition 1994 , Integrated Circuits, K.R. Botkar ,Khanna Publishers , Latest Edition , Satellite Communication, D.C. Agarwal ,Khanna Publishers , Third Edition , A Monograph On Electronic S Design Principles,, N.C.Goyel, R.K.Khetan, ,Khanna Publishers , Second Edition , Operating Systems, Ekta Walia ,Khanna Publishers , 2Nd Edition , Data Structures, Rs Salaria ,Khanna Publishers , 2016 , Electric Power, Sl Uppal ,Khanna Publishers , Latest Edition , Testing, Commissioning, Operation And Maintenance Of Electrical Equipments, S.Rao ,Khanna Publishers , Sixth Edition, 2010 , Electrical Estimation And Costing, Surjit Singh ,Khanna Publishers , Latest Edition , Power Electronics, Dr.P.S.Bimbhra ,Khanna Publishers , Fourth Edition, 2011. , Mechanical & Indtrial Measuments, R.K.Jain ,Khanna Publishers , Latest Edition , Construction Management, Sanga Reddy. S ,Kumaran Publications, Coimbatore , Latest Edition , Fluid Mechanics, R.K. Bansal ,Lakshmi Publications , Latest Edition , Total Quality Management,, V.Jayakumar ,Lakshmi Publications. , (Reprint 2005) , Thermal Enggi., R.K . Rajput,Laxmi Publications Pvt Ltd , 8Th Edition , Fluid Mechanics And Hydraulic Machines, R. K. Bansal ,Laxmi Publications Pvt Ltd , Latest Edition , Engineering Mechanics, R K Bansa ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Dr. B.C. Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Building Construction, Ashokkumar Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume I, Punmia.B.C. Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , 2011 , Theory Of Structures, B.C. Punmia, Ashok Jain & Arun Jain ,Laxmi Publications Pvt.Ltd. , 9Th Edition , Surveying Volume I, Punmia.B.C, Ashok K.Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Surveying Volume Ii & Iii, Punmia.B.C, Ashok Jain & Arun K. Jain ,Laxmi Publications Pvt.Ltd. , Latest Edition , Limit State Design Of Reinforced Concrete, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , R C C Designs, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Environmental Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Waste Water Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Soil Mechanics And Foundation Engineering, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Project Planning And Control With Pert And Cpm, B C Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Buildingconstruction, Dr.B.C.Punmia ,Laxmi Publications Pvt.Ltd. , Latest Edition , Strength Of Materials, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 3Rd Edition, 2010. , Engineering Mechanics, R.K. Bansal ,Laxmi Publications Pvt.Ltd. , 2Nd Edition, 2007 , Thermal Engg, R.K .Rajput ,Laxmi Publications Pvt Ltd , 8Th Edition , Industrial Robotics – Technology, Programming And Applications, P.Groover ,Mc Graw Hill , 2001 , Mobile Cellular Communications, W.C.Y. Lee ,Mc Graw Hill , Second Edition , Electronic Principles And Applications, Charles.A.Schuler ,Mc Graw Hill , 3Rd Edition, 1989 , Geotechnical Earthquake Engineering Hand Book, Robert W.Day ,Mc Graw Hill , Latest Edition , Measurement Systems Application And Design, Ernest O. Doebelin ,Mc Graw Hill , 2004 , Transducers And Instrumentation, D.V.S.Murty ,Mc Graw Hill , 2004 , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , Latest Edition , Digital Integrated Electronics, Taub & Schlling ,Mc Graw Hill , Latest Edition , Optical Fibre Communication, Gerd Keiser ,Mc Graw Hill , Third Edition , Digital Electronics, Roger L.Tokheim Macmillan ,Mc Graw Hill , 1994 , Computer Control Of Manufacturing Systems, Yoram Koren ,Mc Graw Hill , Latest Edition , Engineering Economics And Management, T.R. Banga & S.C. Sharma ,Mc Graw Hill , Editiion 2 – 2001 , Database System Concepts, Silberschatz A. And Korth H ,Mcgraw Hill Education (India) Pvt Limited , 6Th Edition , A Global Perspective, Heinz Weihrich, Harold Koontz ,Mcgraw Hill International Edition ,10Th Edition , Hessentials Of Management’, Herald Koontz And Heinz Weihrich ,Mcgraw Hill Publishing Company , Latest Edition , Power Electronics, Md Singh, Kb Dhanchandaniata ,Mcgraw Hill Publishing Company , Seventeenth Reprint 2005 , Operating Systems, A Concept-Based Approach, Dhananjay M. Dhamdhere ,Mcgraw Hill, Indian Edition , 3Rd Edition , Elements Of Photogrammetry, Wolf Paul (1998) ,Mcgraw Hill, New Delhi , Latest Edition , Manufacturing Process, Begeman . ,Mcgraw Hill, New Delhi1981. , 5Th Edition , Introduction To Environmental Engineering, Mackenzie, L. Davis And A. David, Cornwell. ,Mcgrawhill , Latest Edition , Environmental Engineering, Peary, Rowe And Tchobanoglous ,Mcgrawhill , Latest Edition , Fundamentals Of Digital Logic With Vhdl Design, Stephen Brown And Vranesic ,Mcgrawhill , Latest Edition , Programmable Logic Handbook: Pld, Cpld, And Fpga, Ashok K.Sharma ,Mcgraw-Hill , Latest Edition , Javascript: The Complete Reference, Powell, Thomas ,Mc-Grawhill , 3Rd Edition , Html & Css: The Complete Reference, Thomas Powell ,Mc-Grawhill , 5Th Edition , Jsp: The Complete Reference, Phil Hanna ,Mc-Grawhill , 2Nd Edition , Robotics For Engineers, Yoram Koren ,Mcgraw-Hill Book Co., , 1992 , “Basic Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Advanced Die Making, Eugene Ostergaard.D ,Mcgraw-Hill Book Company , Latest Edition , Hand Book Of Die Design, Ivana Suchy ,Mcgraw-Hill Book Company , Latest Edition , Tool Engineers Hand Book, Astme ,Mcgraw-Hill Book Company , Latest Edition , Robotics Control, Sensing, Vision And Intelligence, Fu.K.S.Gonzalz.R.C., And Lee C.S.G ,Mcgraw-Hill Book Company , 1987 , Audio And Video System – Principles, Maintenance And Troubleshooting , R.Gupta. ,Mcgraw-Hill Book Company ,Second Edition , Computer Organization, V.Carl Hamacher, Zvonko G.Vransic, Safgat G.Zaky ,Mcgraw-Hill Book Company , 5Th Edition , Elements Of Workshop Technology Volume I & Ii, Hajra Chowdry & Bhattacharaya,Media Promoters & Publishers , Latest Edition , Operation And Maintenance Of Electrical Equipment – Volume I & Ii, B.V.S.Rao ,Media Promoters & Publishers , 1St Edition, 1St Reprint 2011 , Elements Of Workshop Technology- Vol. I & Ii,Hajra Choudry & Battacharya ,Media Promoters & Publishers , Latest Edition , Hydraulic Machines, Jagadishlal, ,Metropolitan Book Company New Delhi , Latest Edition , Fluid Mechanics And Hydraulic Machines, Dr. Jagadish Lal ,Metropolitan Book Company New Delhi , Latest Edition , Mechanical Measurements &Control, D.S.Kumar ,Metropolitan Book Company New Delhi , Latest Edition , Introducing Microsoft .Net, David S.Platt ,Microsoft Press , 3Rd Edition , Computer Organization And Design, David A. Patterson And John L. Hennessey ,Morgan Kauffman / Elsevier , 5Th Edition , Complete Knowledge In C, Sukhendu Dey, Debobrata Dutta ,Narosa Publishing House, New Delhi , Reprint 2013 Or Latest Reprint , Software Testing, K.Mustafa And R.A.Khan ,Narosa Publishing House, New Delhi , Reprint 2009 , Software Quality, R.A. Khan, K.Mustafa And Si ,Narosa Publishing House, New Delhi , Reprint 2008 , Building Materials, S.K.Dugga ,New Age International (P) Ltd , 2003 , Reinforced Concrete Design, N Krishnaraju ,New Age International (P) Ltd , Latest Edition , Design Of R C C And Structural Elements ( Rcc Vol I), S S Bhavikatti, ,New Age International (P) Ltd , Latest Edition , G I S Basics, Shahab Fazal ,New Age International (P) Ltd , Latest Edition , Irrigation And Water Resources Engineering, G.L.Asawa ,New Age International (P) Ltd , Latest Edition , Basic Geotechnical Earthquake Engineering,,New Age International (P) Ltd , Latest Edition , Maintenance Of Buildings, A C Panchdhar ,New Age International (P) Ltd , Latest Edition , Engineeringdrawing And Graphics + Autoca, K.Venugopal, ,New Age International (P) Ltd , Latest Edition , Control Of Machines, S.K Bhattacharya ,New Age International (P) Ltd , Second Edition- Reprint 2010 , Quality Manageme, Narayana.V And Sreeniva N.S ,New Age International (P) Ltd , 1996 , Cad/Cam/Cim, R.Radhakrishnan, S.Subramanian ,New Age International (P) Ltd , Latest Edition , Electrical Power System, Clwadhawa ,New Age International (P) Ltd , Fourth Edition, 2009 , Hvdc Power Transmission System & Technology, Kr. Padiyar ,New Age International (P) Ltd , Reprint 2005 , Digital Protection – Protective Relaying From Electromechanical To Microprocessor, Lp Singh ,New Age International (P) Ltd , Second Edition 1997 , Electrical Design Estimating And Costing, K.B.Raina& S.K.Battacharya ,New Age International (P) Ltd , Reprint - 2011 , Control Of Electrical Machines., S.K. Bhattacharya ,New Age International (P) Ltd , Latest Edition , Power Electronics, Mohammed H.Rashid ,New Age International (P) Ltd , Third Edition,2004 , Programming In C, D.Ravichandran ,New Age International (P) Ltd , 1St Edition 1996, Latest Reprint , Linear Integrated Circuits, D.Roychoudhury & Shail.B. Jain ,New Age International (P) Ltd , 2Nd Edition, 2004. , Modern Television Practice– Transmission, Reception, Applications, R.R.Gulati,New Age International (P) Ltd , 5Th Edition , Monochrome & Color Tv , R.R.Gulati ,New Age International (P) Ltd , Latest Edition , Computer Fundamentals Architecture And Organization, B. Ram ,New Age International (P) Ltd , 5Th Edition , Principles Of Data Structures Using C And C++, Vinu V.Das ,New Age International (P) Ltd , Latest Reprint , Practical Scada For Industry, David Bailey Edwin Wright ,Newness , Latest Edition , Programmable Logic Controllers, W. Bolton ,Newness , Latest Edition , Practical C Programming, Steve Oualline ,O’Reilly , 3Rd Edition , Programming Php, Rasmus Lerdorf And Kevin Tatroe ,O’Reilly Publications , 3Rd Edition , Java, A Beginners Guide, Herbert Schildt ,Oracle Press , 6Th Edition , Pc Hardware In A Nutshell, Robert Bruce Thompson. ,Oreilly Media , Third Indian Reprint 2008. , Principles Of Electrical Machine Design, S.K.Sen ,Oxford & Ibh , Latest Edition , Principles Of Gis For Land Resources Assessment, Burrough P A ,Oxford Publication , Latest Edition , Programming In C, Reema Thereja ,Oxford University Press , 2Nd Edition , Digital Electronics, G.K.Kharate ,Oxford University Press , 2010 , Software Engineering Concepts And Application, Subhasjit Dattun ,Oxford University Press , 2010 , Software Engineering Fundamentals, Ali Behforooz And Fredick J Hudson ,Oxford University Press , 2005 , Reinforced Cement Concrete, Mallick And Rangasamy ,Oxford & Ibh , Latest Edition , Digital Communications Fundamentals And Applications, Bernard Sklar & Pabitra Kumar Ray ,Pearson Education , Latest Edition , Advanced Surveying, Sathesh Gopi, R.Sathikumar & N.Madhu ,Pearson Education , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C , Mazidi,Mazidi And D.Mackinlay,,Pearson Education , Latest Edition , Programmable Logic Controllers – Programming Methods And Applications, John R Hackworth And Fredrick D.Hackworth ,Pearson Education , Latest Edition , Principles Of Wireless Networks– A Unified Approach, Kaveh Pahlavan And Prashant Krishnamoorthy ,Pearson Education , 2002 , Electronic Communications Systems - Fundamentals Through Advanced, Wayne Tomasi ,Pearson Education , Fifth Edition , Digital Design, M.Morris Mano Michael D Ciletti ,Pearson Education , Latest Edition , 8051 Microcontrollers, Mazidi And D.Mackinlay ,Pearson Education , Latest Edition , Principles Of Wireless Networks – A Unified Approach, Kaveh Pahlavan And Prashant Krishnamurty ,Pearson Education , Latest Edition , Wireless Communications Principles And Practice, Theodore S. Rappaport ,Pearson Education , Latest Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Second Edition , Mobile Cellular Communication, Gottapu Sasibhushana Rao ,Pearson Education , Latest Edition , Operating System, Internal And Design Principles, William Stallings ,Pearson Education , 9Th Edition , Operating Systems, Deitel And Deitel ,Pearson Education , 3Rd Edition , Computer Organization And Architecture Designing For Performance, William Stallings ,Pearson Education , 10Thedition , Network Security Essentials, William Stallings ,Pearson Education , 5Th Edition , Cryptography And Network Security, William Stallings ,Pearson Education , 6Th Edition , Computer Networks, Andrew S.Tanenbaum ,Pearson Education , 5Th Edition , Web Development And Design Foundations With Html5, Terry Felke-Morris ,Pearson Education , 8Th Edition , Software Engineering, Ian Sommerville ,Pearson Education , Sixth Edition , Software Testing Principles And Practices, Srnivasan Desikan, Gopalswamy Ramesh ,Pearson Education , First Edition , Mobile Communications, Jochen Schiller ,Pearson Education , Latest Edition , Fundamental Of Multimedia, Ze- Nian Li And M.S.Drew. ,Pearson Education , 2Nd Edition , Multimedia Computing, Communication And Applications, Ralf Steinmetz And Klara Nahrstedt ,Pearson Education , Latest Reprint , Multimedia Systems, John F. Koegel Buford ,Pearson Education , Latest Reprint , Total Quality Management, Date H.Besterfiled ,Pearson Education Asia. , Latest Edition , Automation, Production Systems, And Computer-Integrated Manufacturing, Mikell P. Groover ,Pearson Education Asia. , Latest Edition , 8051 Microcontroller And Embedded Systems Using Assembly And C, Mazidi,Mazidi And D.Mackinlay ,Pearson Education Low Price Edition. , Latest Edition , Design Of Steel Structures, K.S.Sai Ram ,Pearson-Porling Kindersley Pvt Ltd , Latest Edition , 8051 Microcontroller, Kenneth Ayala ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Plc And Industrial Automation An Introduction, Madhuchhanda Mitraand Samarjit Sen Gupta ,Penram International Publishing (India) Pvt Ltd , Latest Edition , Industrial Energy Conservation-, D. A. Ray- ,Pergaman Press , Latest Edition , Electronics Devices And Circuit Theory, Boyestad & Nashelsky ,Phi , Latest Edition , Electronic Devices & Circuits An Introduction, Allen Mottershed,Phi , Latest Edition , Computer Graphics Multimedia And Animation,, Malay K. Pakhira ,Phi , 2Nd Edition , Principles Of Digital Electronics, K.Meena ,Phi , 2011 , Operational Amplifiers And Linear Integrated Circuits, Robert F. Coughlin Frederick F. Driscoll ,Phi , 1992 , Op. Amp & Linear Integrated Circuits, Ramakant. A. Gayakwad ,Phi , 1992 , Digital Electronics- An Introduction To Theory And Practice, William H.Gothmann ,Phi , 1998 , Transducers And Instrumentation, Dvs Murty ,Phi , 2009 , Measurement And Instrumentation, Arun. K ,Phi , 2010 , Sensor And Transducers, D. Patranabis ,Phi , 2011 , Elements Of Engineering Mechanics, Sanchayan Mukherjee ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass, ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Structural Analysis, Madhan Mohan Dass ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Surveying, Mimi Das Saikia, B Mohan Das & M Mohan Das ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Fundamentals Of Surveying, S. K. Roy ,Phi Learning Pvt. Ltd., New Delhi. , Edition 2010 , Limit State Design Of Reinforced Concrete, P C Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, .M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Principles Of Environmental Science And Engineering,, P.Venugopala Rao ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Irrigation And Water Power Engineering, Madan Mohan Das&Mimi Das Saikia ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Limit State Design In Structural Steel, M.R.Shiyekar ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Buildingconstruction, P.C.Varghese ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Energy Engineering And Management, Amlan Chakrabarti ,Phi Learning Pvt. Ltd., New Delhi. , Latest Edition , Power Electronics, M.S.Jamil Asghar ,Phi Learning Pvt. Ltd., New Delhi. , Eastern Economy Edition, 2010 , Principles Of Digital Electronics, K.Meena ,Phi Learning Pvt. Ltd., New Delhi. , 2009 , Operating System, Principles & Design, Pabitra Pal Chaudhuri ,Phi Learning Pvt. Ltd., New Delhi. , 1St Edition , Computer Organization & Architecture, Rajaraman ,Phi Learning Pvt. Ltd., New Delhi. , Latest Reprint , Fundamentals Of Software Engineering, Rajib Mall ,Phi Learning Pvt. Ltd., New Delhi. , 28Th Printing – August 2011 , A Textbook On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Electronics Devices And Circuit Theory , Boyestad & Nashelsky ,Phi Publication, New Delhi , 2009 , Electronicsdevices And Circuits, Allen Mottershed ,Phi Publication, New Delhi , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D.Helfrick And Willam David Cooper ,Phi Publication, New Delhi , 1996 , A Text Book On C, E.Karthikeyan ,Phi Publication, New Delhi , 2008 , Power Electronics, M.H.Rashid ,Phi Publication, New Delhi , 3Rd Edition-2005 , Industrial Electronics And Control, Biswanath Paul ,Phi Publication, New Delhi , 2Nd Edition -2010 , Programmable Logic Controllers, Frank D.Petruzela ,Phi Publication, New Delhi , 2Nd Edition- 1998 , Programmable Logic Controllers Principles And Applications, John W. Webb. Ronald A. Reis ,Phi Publication, New Delhi , Latest Edition , Networks Lines And Fields, John D.Ryder ,Phi Publication, New Delhi , Latest Edition , Electronic Communication, Dennis Roddy And John Colen ,Phi Publication, New Delhi , Latest Edition , Principles Of Digital Electronics, K.Meena ,Phi Publication, New Delhi , Latest Edition , Digital Electronics, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Digital Electronics – An Introduction To Theory And Practice, William H.Gothmann ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Ramakant A Gayakwad ,Phi Publication, New Delhi , Latest Edition , Operational Amplifiers And Linear Integrated Circuits, Robert F.Coughlin And Frederick F.Driscoll ,Phi Publication, New Delhi , Latest Edition , Microcontrollers, Principles And Applications, Ajit Pal ,Phi Publication, New Delhi , Latest Edition , Vhdl Primer, Bhasker J ,Phi Publication, New Delhi , Latest Edition , Digital Electronics With Pld Integration, Nigel P. Cook ,Phi Publication, New Delhi , Latest Edition , Digital Logic Simulation And Cpld Programming With Vhdl, Steve Waterman ,Phi Publication, New Delhi , Latest Edition , Data And Computer Communications, William Stallings ,Phi Publication, New Delhi , Latest Edition , Computer Networks , Andrew S.Tanenbaum ,Phi Publication, New Delhi , Latest Edition , Wireless Digital Communications, Kamilo Feher ,Phi Publication, New Delhi , Latest Edition , Wireless Communications And Networks, William Stallings ,Phi Publication, New Delhi , Latest Edition , Irrigation Water Management, Dilip Kumar Majumdar ,Phi Publication, New Delhi , Latest Edition , Multimedia Systems Design., Prabhat K.Andleigh, Kiran Thakra ,Phi Publication, New Delhi , Latest Edition , Performance And Design Of Ac Machines, M.G.Say ,Pitman Publishing Ltd , Latest Edition , Principles Of Management, M.Govindarajan And S.Natarajan ,Prentice-Hall Of India (P) Ltd , Latest Edition , Modern Electronic Instrumentation And Measurement Techniques, Albert D. Helfrick William David Cooper ,Prentice-Hall Of India (P) Ltd , Latest Edition , Building Materials, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Building Constructions, P.C.Varghese ,Prentice-Hall Of India (P) Ltd , 2011 , Geographic Information Systems, Lo & Yeung (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Geographic Information Systems & Environmental Modelling, Clarke Parks & Crane (2005) ,Prentice-Hall Of India (P) Ltd , Latest Edition , Foundation Design, Wayne C.Teng ,Prentice-Hall Of India (P) Ltd , Latest Edition , Operations Research, H.A.Taha ,Prentice-Hall Of India (P) Ltd , Latest Edition , Total Quality Management – An Introductory Text, Paul James ,Prentice-Hall Of India (P) Ltd , Latest Edition , Electronic Device And Circuits- An Introduction, Allen Mottershed,Prentice-Hall Of India (P) Ltd , Latest Edition , Techniques Of Press Working Sheet Metal, Donald F. Eary. & Edward A. Reed ,Prentice-Hall Of India (P) Ltd , Latest Edition , Essentials Of Management, Joseph L.Massie ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Elements Of Electrical Engineering, Maria Louis ,Prentice-Hall Of India (P) Ltd , Latest Edition , Digital Electronics, William H.Gothmann ,Prentice-Hall Of India (P) Ltd , Latest Edition , Programmable Logic Controllers – Principle And Applications, John W. Webb ,Prentice-Hall Of India (P) Ltd , Latest Edition , Computer Networks, Andrew S.Tanenbaum ,Prentice-Hall Of India (P) Ltd , 2002 , Data And Computer Communications, William Stallings ,Prentice-Hall Of India (P) Ltd , Eighth Edition 2007 , Computer System Architecture, M.Morris Mano ,Prentice-Hall Of India (P) Ltd , 3Rd Edition , Data Structures A Programming Approach With C, Dharmender Singh Kushwaha And Arun Kumar Misra ,Prentice-Hall Of India (P) Ltd , 2012, Latest Reprint , Classic Data Structures, Debasis Samanta ,Prentice-Hall Of India (P) Ltd , 2Nd Edition , The Internet, Douglas E.Comer ,Prentice-Hall Of India (P) Ltd , 4Th Edition , Introduction To Biomedical Instrumentation, Mandeep Singh,Prentice-Hall Of India (P) Ltd , Latest Edition , Iso 9001, Brain Rethry, Brain Rethry ,Productivity And Quality Publishing Pvt. Ltd. , 1993 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 2008 , Surveying And Levelling Part 1 & 2, Kanetkar.T.P. & S.V.Kulkarni ,Puna Vidyarthi Griha, Prakashan , 23Rd Edition , Limit State Theory And Design Of Reinforced Concrete, S.R.Karve And V.L.Shah ,Puna Vidyarthi Griha, Prakashan , 5Th Edition , A Course In Electrical And Electronics Measurements And Instrumentation, A.K. Sawhney ,Puneet Sawhney Dhanpat Rai & Co (P) Ltd. , Latest Edition , Upgrading And Repairing Laptops, Scott Mueller ,Que Publication , Latest Edition , A Text Book Of Fluid Mechanics And Hydraulic Machines,By, R. K Rajput And S.Chand ,R. K Rajput And S.Chand & Co, New Delhi , Latest Edition , Training Manual On Iso 9001 : 2000 & Tqm, Girdhar J.Gyani ,Raj Publishing House , Latest Edition , Electrical Machine Design, A.Naoor Kani ,Rba Publications , Latest Edition , A Course In Electrical Engineering , B.L.Theraja ,S.Chand & Company Ltd, New Delhi ,Reprint 2006 , A Text Book Of Transportation Engineering, S P Chandola ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R.S.Khurmi ,S.Chand & Company Ltd, New Delhi , Latest Edition , Strength Of Materials, R. S. Khurmi, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Production Technology , P. C. Sharma ,S.Chand & Company Ltd, New Delhi ,Edn. X , Thermal Engineerin, , R.S. Khurmi, J.K Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , A Text Book Of Hydraulics, Fluid Mechanics And Hydraulic Machines,R.S. Khurmi ,S.Chand & Company Ltd, New Delhi ,Edn.18 , Thermal Engineering, R.S. Khurmi And J.K. Gupta ,S.Chand & Company Ltd, New Delhi , 18Th Edition , The Automobile, Harbans Singh Reyat, S.Chand,S.Chand & Company Ltd, New Delhi , Latest Edition , Non Conventional Energy Sources And Utilisation , R.K. Rajput - S.Chand ,S.Chand & Company Ltd, New Delhi , 2012 , A Text Book Of Electrical Technology Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , A Text Book Of Electrical Technology -Volume Ii, B.L. Theraja ,S.Chand & Company Ltd, New Delhi , Latest Edition , Principles Of Power System, V.K.Metha ,S.Chand & Company Ltd, New Delhi , 4Th Edition Reprint 2007 , Electronic Measurements And Instrumentation, R.K.Rajput ,S.Chand & Company Ltd, New Delhi , 3Rd Edition 2009 , Computer Concepts And C, Dr.S.S.Khandare ,S.Chand & Company Ltd, New Delhi , 1St Edition 2010, Latest Reprint , Electrical Technology Vol I And Ii, B.L.Theraja ,S.Chand & Company Ltd, New Delhi , Mutiple Colour Edition,2012 , Principles Of Electronics, V.K.Mehta ,S.Chand & Company Ltd, New Delhi , Second Edition , Electronics And Instrumentation, Dr.S.K.Battachariya Dr. Renu Vig ,S.K. Kataria & Sons, New Delhi , Latest Edition , Principles Of Electrical Machine Design, R.K.Agarwal ,S.K. Kataria & Sons, New Delhi , Latest Edition , Environmental Engineering And Management, Dr.Suresh K.Dhameja- ,S.K. Kataria & Sons, New Delhi , Latest Edition , Soil Mechanics & Foundation Engineering, V N S Murthy ,Sai Kripa Technical Consultants , Latest Edition , Digital Communications, Dr.K.N.Hari Bhat Dr.D.Ganesh Rao ,Sanguine Technical Publisher , Latest Edition , Energy Resource Management, Kirpal Singh Jogi- Sarup And Sons ,Sarup And Sons , Latest Edition , A Course In Electrical And Electronic Measurement And Instrumentation, Umesh Sinha ,Satya Prakashan, New Delhi , Latest Edition , Electrical And Electronics Measurements And Instrumentation, Umesh Sinha ,Satyaprakashan Tech , 1992 , Theory And Problems Of Machine Design, Holowenko, Laughlin ,Schaum’S Outline Series. , Latest Edition , Data Structures With C, Seymour Lipschutz ,Schaums Outlines, Tmh , Latest Reprint , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication , Latest Edition , Microprocessor And Microcontroller, R.Theagarajan ,Sci Tech Publication, Chennai. , Latest Edition , Limit State Design Of Concrete Structures, Dr.S.Ramachandra ,Scientific Publishers , Latest Edition , Murach’S Mysql, Joel Murach ,Shroff / Murach , 2012, Latest Reprint , Fundamentals Of Tool Design, Dr.John G.Nee ,Society Of Manufacturing Engineers. , Latest Edition , Electrical Machine Design, C.Eswarlal ,Sonaversity , Latest Edition , A Concise Introduction To Software Engineering, Pankaj Jalote ,Springer, Latest Edition , Design Of Electrical Machine, Mittle V.N ,Standard Book – House , Latest Edition , Fluid Mechanics, P.N. Modi & S.M. Sethi ,Standard Publishers & Distributors, New Delhi , Latest Edition , Water Supply And Sanitary Engineering Vol I & Ii, Gurcharan Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Hydraulics, Fluid Mechanics And Hydraulics Machines, K.R. Arora ,Standard Publishers & Distributors, New Delhi , Latest Edition , Automobile Engineering Vol- 1, Vol – 2,Kirpal Singh ,Standard Publishers & Distributors, New Delhi , Latest Edition , Learning Material Development Project,,Taramani, Chennai, Cd Programme On Gps And Gis , Latest Edition , Principles Of Transportation & Highway Engineering, G V Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, N.N. Basak ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Environmental Engineering, A.Kamala,D.L.Kanthrao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Engineering Hydrology, K.Subramanya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Production And Operations Management, S.N. Chary ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Essentials Of Management, Koontz &Weihrich ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Business Correspondence & Report Writing, R.C. Sharma And K.Mohan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , How To Prepare For Group Discussion & Interview (With Audio Cassette), Prasad ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Construction Management And Planning, Sengupta.B, &H.Guha ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Applications In Construction, Boyd.C. & Paulson Jr ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Fluid Mechanics And Machinery, B C S Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Geotechnical Earthquakes Engineering Hand Book,,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials, S.S.Rattan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Strength Of Materials,B K Sarkar ,Tata Mcgraw-Hill Publishing Company Ltd , I Edition, 2003 , Production Technology,,Tata Mcgraw-Hill Publishing Company Ltd ,Edn. 18. 2001 , Autocad With Applications, Sham Tickoo,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynami, Pk Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , Production Technology, Hmt, ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 18 , Manufacturing Process, Myro N Begman ,Tata Mcgraw-Hill Publishing Company Ltd , Edn. 5 , Production Processes, Nitttr, ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Circuits & System- Analog And Digital , Y.N.Bapat ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Applied Thermodynamics, P.K. Nag ,Tata Mcgraw-Hill Publishing Company Ltd , 2Ndedition , Quality Management, Howard Cuitlow ,Tata Mcgraw-Hill Publishing Company Ltd , 1998 , Quality Planning And Analysis, Juran J.M And Frank M.Gryna Jr. ,Tata Mcgraw-Hill Publishing Company Ltd , 1982 , Tool Design, Donaldson ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Non-Conventional Energy Resources ,B.H.Khan ,Tata Mcgraw-Hill Publishing Company Ltd ,2Nd Edn, 2009. , Cad/Cam Principles And Applications, Dr.P.N.Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cad/Cam, Ibrahim Zeid ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Measurement Systems, E. O. Doebelin ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Robotics And Image Processing, Janakiraman.P.A ,Tata Mcgraw-Hill Publishing Company Ltd , 1995 , Circuits And Networks Analysis And Synthesis., A. Sudhakar Shyammohan S Palli ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electric Circuits, Mahamood Nahvi Joseph A Edminister ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Nagarath ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Machines, Bhattacharya ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices & Circuits, Jacob Millman And Halkias ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Optical Fiber Communication, Gerdkeise ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Instrumentation, Hs Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P.Jains ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles & Applications, Albert Paul Malvino & Donaldp.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Introduction To Microprocessor, Aditya P Mathur ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Power System Protection And Switchgear, B Ram & Dn Viswakarma ,Tata Mcgraw-Hill Publishing Company Ltd , Reprint 2000 , Programmable Logic Controllers, Frank D.Petruzella ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electrical Power Distribution System, As Pabla ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Utilization Of Electric Power, Nv Suryanarayana ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Troubleshooting, Maintaining And Repairing Pcs, Stephen J Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , 2006 , Computer Networks, Achyut Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronics Devices And Circuits, Salivahanan S, N.Suresh Kumar, A.Vallavaraj ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2016 , Electronic Principles , Malvino ,Tata Mcgraw-Hill Publishing Company Ltd , 2010 , Electronicsdevices And Circuits, Jacobmillmanandhalkias ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition 2010 , Electronic Instrumentation, Kalsi ,Tata Mcgraw-Hill Publishing Company Ltd , 2004 , Programming In Ansi C , E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Programming And Problem Solving Using C, Isrd Group, Lucknow ,Tata Mcgraw-Hill Publishing Company Ltd , 2008 , Electronic Communication Systems, Kennedy ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, Arvind M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Communication Electronics Principles And Application , Louis E Frenzel ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Principles And Applications, Albert Paul Malvino & Donald P.Leach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Linear Integrated Circuits, Salivahanan & V.S.Kanchana Baskaran ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Electronic Communication Systems, Kennedy – Davis ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Digital Communication, P.Ramakrishna Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Principles Of Communications System, Taub &Schilling ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Computer Installation And Servicing, D.Balasubramanian ,Tata Mcgraw-Hill Publishing Company Ltd , Second Edition 2010 , Troubleshooting, Maintaining And Repairing Pcs, Stephen J.Bigelow ,Tata Mcgraw-Hill Publishing Company Ltd , Fifth Edition , Ibm Pc And Clones, B.Govindrajalu ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Data Communication And Networking, Behrouz A.Forouzan ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Tv And Video Engineering, By A.M.Dhake ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Color Tv, Theory And Practice, S.P.Bali ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Modern Digital Electronics, R.P. Jain ,Tata Mcgraw-Hill Publishing Company Ltd , Third Reprint 2010 , Basic Electricall Engineering, V.N.Mittle ,Tata Mcgraw-Hill Publishing Company Ltd , First Edition , Basic Electrical And Electronics Engineering, R,Muthusubramanian R.Salivajanan ,Tata Mcgraw-Hill Publishing Company Ltd , Seventh Reprint 2011 , Computer Architecture And Organization, John P. Hayes ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Data Communication And Networking, Behrouz A.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Computer Communications And Networks, Achyuts.Godbole ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Cryptography And Network Security, Behrouza.Forouzen ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Programming With Java, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 5Th Edition , Data Structures And Algorithms, G.A.Vijayalakshm I Pai ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Reprint Or Latest Reprint , Data Structures Using C, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Programming In C#, E. Balagurusamy ,Tata Mcgraw-Hill Publishing Company Ltd , 3Rd Edition , Applications Of .Net Technology, Isrd Group ,Tata Mcgraw-Hill Publishing Company Ltd , 1St Edition Or Latest Reprint , Cloud Computing A Practical Approach 2008 Edition, Cloud Computing A Practical Approach ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Software Engineering, Stephen Schach ,Tata Mcgraw-Hill Publishing Company Ltd , Eight Reprint 2011 , Mobile Computing, Asoke K Talukder,Hasan Ahmed, Roopa R Yavagal ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Edition , Multimedia: Making It Work., Tay Vaughan ,Tata Mcgraw-Hill Publishing Company Ltd , 8Th Edition , Multimedia Communication Systems: Techniques, Standards, And Networks, K.R. Rao ,Tata Mcgraw-Hill Publishing Company Ltd , Latest Reprint , Principles Of Multimedia, Ranjan Parekh ,Tata Mcgraw-Hill Publishing Company Ltd , 2Nd Edition , The Complete Reference Linux, Richard Peterson ,Tata Mcgraw-Hill Publishing Company Ltd , 6Th Edition , A Text Book Of Engineering Drawing,R.B. Gupta ,Technical India Publications, New Delhi , Latest Edition , Digital Communication, Dr. J.S.Chitode ,Technical Publications – Pune , Latest Edition , Introduction To Plc, Gary Dunning ,Thomson Del Mar Learning , 3Rd Edition , Data Structures Using C – 1000 Problems And Solutions, Sudipta Mukherjee ,Tmgh, New Delhi , 2Nd Reprint Or Latest Reprint , Industrial & Power Electronics, Harish C.Rai ,Umesh Publications , 2017 , Construction Engineering & Management, Seetharaman. S ,Umesh Publications , Latest Edition , Introduction To Earthquake Engineering,,University Of Tokyo Press , Latest Edition , Digital Electronics And Logic Design, Jaydeep Chakravarthy ,University Press, Hyderabad , First Edition2012 , Introduction To Data Structures Using C, Venkatesh N.Baitipuli ,University Science Press, Chennai , 1St Edition, 2009 Or Latest Reprint , Software Engineering, Rohit Khurana ,Vikas Publishing Ltd , Second Edition , Organizational Behaviours, S.Chandran ,Vikas Publishing Ltd , Latest Edition , Operating Systems, Rohit Khurana ,Vikas Publishing Ltd , 2Nd Edition , Workshop Technology, Waj Chapman ,Vima Books Pvt. Ltd New Delhi , Latest Edition , Energy Auditing In Electrical Utilities, Rajiv Shankar ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Workshop Tech Vol I,Ii, Iii, Waj. Chapman ,Viva Books Pvt. Ltd., New Delhi , Latest Edition , Wireless And Mobile Network Architectures, Yi-Binglin, Imrich Chlamtac ,Wiley , Latest Edition , Wireless Networks, P. Nicopolitidis ,Wiley , Latest Edition , Operating System Concepts, Abraham Siberschatz, Galvin, Gagne ,Wiley , 9Th Edition , Microprocessor Architecture Programming And Application, Ramesh S. Gaonkar, ,Wiley Eastern Ltd , Latest Edition , Introduction To System Design Using Ic, B.S. Sonde ,Wiley Eastern Ltd , Latest Edition , Fundamentals Of Acoustics, Kingsler And Frey,Wiley Eastern Ltd , Latest Edition , Beginning Android 4 Application Development, Wei-Meng Lee ,Wiley India Edition , Latest Edition , Power Electronics, Mohan, Undeland, Robbins. ,Wiley India Edition. , Media Enhanced Third Edition , Web Programming, Chris Bates ,Wiley India, New Delhi, 3Rd Edition , Cloud Security: A Comprehensive Guide To Secure Cloud Computing, Ronald L. Krutz Russell Dean Vines ,Wiley Publishing, Inc , Latest Edition , Cloud Computing Bible, Barrie Sosinsky ,Wiley Publishing, Inc. , Latest Edition , Total Quality Management For Engineers, Zeiri ,Wood Head Publishers , 1991 , Mechanics Of Structures- Vol 1, S.B.Junnarkar , , Latest Edition , I S 2185 Part I & Ii, Ernest O. Doebelin , , Latest Edition , Pwd & Cpwd Specifications, D.V.S.Murty , , Latest Edition , National Building Code,, , Nbc-2012 , Tamilnadu District Municipal Building Rules And By-Laws,, , Latest Edition , Civil Engineering Drawing And House Planning, B.P. Verma , , Latest Edition , Building Planning And Drawings, Dr N. Kumaraswamy And A. Kameswara Rao , , Latest Edition , Building Planning And Construction, G. Vaidhyanathan, I. Kulasekaran, G. Sathish Kumar , , Latest Edition , Civil Engineering Drawing, S.C.Rangwala , , Latest Edition , A Guide To Civil Engineering Drawing, V.R.Thothathri , , Latest Edition , Theory Of Structures, S. Ramamrutham , , Latest Edition , Analysis Of Structures, V.N. Vazirani & M.M. Ratwani , , Latest Edition , Elementary Theory Of Structures, R.L. Jindal , , Latest Edition , Strength Of Materials, Fv. Warnock , , Latest Edition , Estimating & Costing, Bridie , , Latest Edition , Indian Standard Code Of Practice, Is:1200,, , Latest Edition , I S 456-2000 ; I S 875-1987; I S 800 -2007,, , Latest Edition , Explanatory Hand Book Sp24, Design Aid Sp 16,Detailing Of Reinforcement,Sp 34,, , Latest Edition , Concrete Technology , M.S. Shetty , , Latest Edition , Fire Resistant Construction – Building Construction, S.P.Arora And S.P.Bindra , , Second Edition , Earth Quake Proof , Dr.Janardhanjha And Prof.Suresh Kumar , , Latest Edition , Sinha Is Code Of Practice For Earth Quake , Is Code Of Practice For Fire Resistance, Is Code Of Practice For Pre Stressing,, , Latest Edition , Pile Foundation, Rd Chellis, Mis , , Latest Edition , Construction And Foundation Engineering, Sinha & Janatha Shau , , Latest Edition , Principle Fine Safety Standards For Building Construction, M.Ya Roytman , , Second Edition , Remote Sensing And Geographical Information Systems, Anji Reddy.M. (1998) , , Latest Edition , Analysis And Design Of Substructures (Lsd) – Second Edition 2010, Swami Saran , , Latest Edition , Civil Engineering Drawing, M Chakrabort , , Latest Edition , Civil Engineering Drawing, Gurucharan Singh & Subhash Chandar Sharma , , Latest Edition , Civil Engineering Drawing Manual, S Chand & Company (Pvt) Ltd. , , Latest Edition , Production Systems: Planning, Analysis And Control, J.L.Riggs, 3Rd Ed , , Latest Edition , Productions And Operations Management, A.Muhlemann, J.Oakland And K.Lockyer, Macmillan , , Latest Edition , Operations Research, J.K.Sharma, Macmillan , , Latest Edition , Spoken English – A Self-Learning Guide To Conversation Practice (With Cassette),, , Latest Edition , Quality Control And Applications, Housen&Ghose , , Latest Edition , Industrial Engineering Management, O.P. Khanna , , Latest Edition , Steel Structures, Dr.Subramaniam , , Latest Edition , Town Planning, S.C. Rangwala , , Latest Edition , Town Planning, K.S.Rangwala And P.S.Rangwala , , Latest Edition , Remote Sensing Methods And Application, Michael Hord, R , , Latest Edition , National Building Code Of India- Part-Iii.(2005),, , Latest Edition , Municipal And Panchayat Bye-Laws, Cmda Rules And Corporation Bye-Laws.,, , Latest Edition , Urban And Regional Planning, Ka. Ramegowda , , Latest Edition , Earthquake Resistant Design Of Structures, Pankaj Agarwal And Manish Shrikhande , , Latest Edition , Guidelines For Earthquake Resistant Non Engineered Construction, The Associated Cement Companies Ltd , , Latest Edition , Criteria For Earthquake Resistant Design Of Structures - General Provisions And Buildings, Is: 1893 ( Part 1 ) - 2002,, , Latest Edition , Code Of Practice For Ductile Detailing Of Rc Structures Subjected To Seismic Forces, Is:13920-1993.,, , Latest Edition , Earthquake Tips, C.V.R.Murty, , , Latest Edition , Indian Standard Code Of Practice, Is:1200.,, , Latest Edition , Estimating And Costing, Vazirani & Chandolu , , Latest Edition , Geometrical And Machine Drawing, N.D. Bhatt, Anand , , Latest Edition , Hydraulics, Andrew Parr , , Latest Edition , Fundamentals Of Pneumatic Control Engineering, Festo Manual , , Latest Edition , Electrical Technology, Hughes, , 8Th Edition , Machine Design Bandari,,, , Latest Edition , Industrial Engineering & Management, O.P Khanna , , Latest Edition , Industrial Engineering & Production Management, Martand Telsang , , Latest Edition , Production Engineering , P.C.Shrma. , , Latest Edition , Production And Costing, Gbs Narang And V.Kumar , , Latest Edition , Mechanical Estimating And Costing , Banga & Sharma. , , Latest Edition , Quality Auditing, D.Mills, Chapman And Hall , , 1993 , Refrigeration And Air Conditioning, V.K. Jain, , , Latest Edition , Industrial Refrigeration Hand Book, Wilbert F. Steocker , , Latest Edition , A Course In Refrigeration And Air Conditioning , Domkundwar , , Latest Edition , Principles Of Refrigeration, Dossat, , Latest Edition , Electronic Principles , Malvino , , Latest Edition , Microcontrollers, Principles And Applications – Ajit Pal – Phi Ltd., - 2011.,, , Latest Edition , Biomedical Instrumentation ,Anuradha Publications, Chennai, Dr.M. Arumugam , , Latest Edition , Bio Medical Instrumentation And Measurements, Ii Edition., Leslie Cromwell –Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering., Jacobson And Webstar , , Latest Edition , Hand Book Of Bio –Medical Instrumentation., R.S .Khandpur , , Latest Edition , Medical Electronics, Kumara Doss , , Latest Edition , Introduction To Medical Electronics, B.R. Klin , , Latest Edition , Introduction To Biomedical Instrumentation , Mandeep Singh Printice Hall India 2010. , , Latest Edition , Digital Communications, John G.Prokais , , 2011 , Biomedical Instrumentation And Measurements, Leslie Cromwell, Fred J. Wibell, Erich A.P Feither , , Latest Edition , Medicine And Clinical Engineering, Jacobson And Webstar , , Latest Edition , Hand Book Of Bio–Medical Instrumentation., R.S .Khandpur , , Latest Edition , Engineering Mathematics - Dr.M.K.Venkatraman, National Publishing Co, Chennai 2. , Engineering Mathematics – Dr.P.Kandasamy & Others, S.Chand & Co Ltd, New Delhi , Physics, Resnick And Haliday–Wisley Toppan Publishers–England , Engineering Physics–B.L.Theraja–S. Chand Publishers , A Text Book Of Sound–R.L. Saighal & H.R. Sarna–S.Chand & Co. , Mechanics–Narayana Kurup–S. Chand Publishers. , Fundamentals Of Physics – Brijlal And Subramaniam. , Fundamentals Of Electricity – D.N. Vasudeva – S. Chand & Co , Non-Conventional Energy Sources – G.D. Rai.- Khanna Publishers , Text Book Of Remote Sensing And Geographical Information Systems – M. Anji Reddy Bs Publications. , Engineering Chemistry – Jain & Jain – Dhanpat Rai & Sons. , A Text Book Of Engineering Chemistry – S.S. Dara – S. Chand Publication. , A Text Book Of Environmental Chemistry And Pollution Control – S.S. Dara – S. Chand Publication. , Engineering Chemistry – Uppal – Khanna Publishers. , Environmental Chemistry – V P Kudesia – Pragati Publishers. , Chemistry Of Engineering Material – C.V. Agarwal, Andranaidu C. Parameswara Moorthy – B.S. Publications. , A Text Book Of Inorganic Chemistry – P.L. Soni – S. Chand Publication. , Rain Water Harvesting – Hand Book – Chennai Metro Water. , Bhatt N.D. And Panchal V.M., “Engineering Drawing”, Charotar Publishing House, 50Th Edition, 2010. , Gill P.S., “Engineering Drawing”, S.K.Kataria & Sons. , Gopalakrishnan.K.R., Engineering Drawing, (Vol.I And Vol.Ii), Dhanalakshmi Publishers, Edition 2 , Venugopal.K, Sreekanjana G, “Engineering Graphics” New Age International Publishers. , K V Nataraajan “A Text Book Of Engineering Drawing” , Besant Agrawal, C M Agrawal “Engineering Drawing”, Tata Mcgraw Hill Education Private Limited. , Barkinson & Sinha, First Year Engineering Drawing, Pitman Publishers. , Communication Skill, Sanjay Kumar Pushp Lata, Oxford University Press , Communication Skill, , Gph Publication , English Communication Teory And Practical, Manoj Kumar Garg, Scholar Tech Press , Little Redbook - Grammar Made Easy, Terry O Brien
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 2
46.
Drinking Water Supply and Sanitation #10030676 Technical Bid
Tender For E-Quotation For Seeking Firm Rates Of Plant & Machinery And Materials Category Items For Preperation/Amendment Of Schedule Of Rate For The Year 2026.- M 1055 - Pumpssupplying Submersible Pump Sets Confirming To Is 8034 And Motor Confirming To Is 9283. Pump Shall Be Suitable For Various Delivery Head And Discharge With Stainless Steel Pump Shaft And Polypropylene/ Noryl Impeller. Motor Suitable For Working On 415V+10%, 3Ph, 50 Hz, A.C. Supply With Cable Guard, Thrust Carbon/ Fiber Bearing To Withstand Entire Hydraulic Thrust, Water Proof Winding Shall Be Provided. The Pump Set Shall Be Suitable For Direct Coupling. Pump Shall Have Suitable Outlet As Per Manufacturers Design. Anti Thrust Stream Lined Non Return Valve Shall Be Provided With Pump. 3 Meter Submersible Copper Conductor Cable In Single/ Double Run Shall Be Provided With Each Pump. Submersible Pump Set 100 Mm Dia (With Polypropylene/ Noryl Impeller) Up To 20 Stages1 H.P. 1.5 Hp 2.5 Hp 3.0 Hp 4.0 Hp 5.0 Hp Submersible Pump 150 Mm Dia (With Bronze/Ss Impeller) Up To 8 Stages 1.5 Hp 2.0 Hp 3.0 Hp 4.0 Hp 5.0 Hp 6.0 Hp 7.5 Hp M 1056 - Pressure Guageproviding Fabricating, Testing And Commisioning Pressure Vessel Fabricating In M.S Plate On Providing Foundation Including Epoxy Paint Pressure Gauge (100 Mm Dia) Pressure Gauge (150 Mm Dia) Vacuum / Combination Gauge M 1057 - Lifting Equipmentchain Pulley Blocksupplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. 20 M 1057 - Lifting Equipmentchain Pulley Blocksupplying Triple Spur Gear Type Chain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. 21 1 Tonne Capacity 22 2 Tonne Capacity 23 3 Tonne Capacity 24 Electric Operated Circular Or Rectangular Travelling Crane (Single Girder)Supplying Single Girder Electrically Operated Rectangular Over Head Travelling Crane With 6 M Lift Complete With Wire Rope Hoist, Class Ii Duty, All Three Motions Electrically Operated By Suitable Rating Motor Ip 54, Control Panel And Down Pendant Control Block. 25 5 Tonne Capacity 26 Above 6 M Up To 8 M Span 27 Above 8 M Up To 10 M Span 28 7.5 Tonne Capacity 29 Above 6 M Upto 8 M Span 30 Above 8 M Up To 10 M Span 31 10 Tonne Capacity 32 Above 6 M Up To 8 M Span 33 Above 8 M Up To 10 M Span 34 M 1058 - Lightening Arrester, Ab Switch, Insulators M 1058 - Lightening Arrester, Ab Switch, Insulators Lightening Arrestorsupplying, Erecting Approved Make Thyrite Type Lightening Arrestor Suitable For H.T. Supply With Necessary Ancillary Material Complete On Provided Cross Arm And Connected To Overhead Line. Suitable For 11 Kv Supply, Distribution Class Suitable For 22 Kv Supply, Distribution Class Suitable For 33 Kv Supply, Station Class Disc Insulator.Supplying, Erecting Porcelain Disc Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm Suitable For 11Kv Line Suitable For 33Kv Line Pin Insulatorsupplying, Erecting Porcelain Pin Type Insulators With Hardware Fittings Suitable For H.T. Overhead Line Complete Erected With Nuts And Bolts On Provided Cross Arm Suitable For 11Kv Line Suitable For 33Kv Line Air Break Switch Without Earth Switchsupplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps Suitable For 11Kv Line 46 Suitable For 11Kv Line 47 Rocking / Tilting Type 48 Rotating Type 49 Suitable For 33Kv Line 50 Rocking / Tilting Type 51 Rotating Type 52 Air Break Switch With Earth Switchsupplying, Erecting Approved Make H.T. Outdoor Type Gang Operated Air Break Triple Pole Switch With Earth Switch Of Required Capacity With 3 Post / Pin Type Insulator Per Phase , Mounted In Horizontal Or Vertical Position On Provided Cross Arm With Adequate Length Of G.I. Pipe For Operating Handle Erected On Extended Square Shaft. The Operating Handle Provided With Lock And Key At Suitable Height From Ground With Necessary Clamps 53 Suitable For 11 Kv Line 54 Rotating Type 55 Suitable For 33 Kv Line 56 Rotating Type 57 Drop Out Fuse (Channel Mounted)Supplying, Erecting Approved Make Out Door Type Drop Out Fuse Channel Type With Insulator Complete With Fuse Holders Fuse Barrel With Metal Fittings, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units 58 Suitable For 11 Kv Line Suitable For 11 Kv Line Suitable For 33 Kv Line Horn Gap Fuse (Channel Mounted) Supplying, Erecting Approved Make Out Door Type Horn Gap Type Fuse With Insulator, Fuse Element, With Working Current Up To 50 Amp, Capacity Complete Erected On Provided Cross Arm, Each Set Comprising 3 Units Suitable For 11 Kv Line Suitable For 33 Kv Line M 1059 - Transformerpower Transformer (With Off Load Tap Changer) Any Isi Mark Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2 Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issed By Seb Which Ever Are Lower-1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge.2. Silica Gel Dehydrating Breather Charged With Silica Gel.3. Oil Drain Valve4. Oil Filter Valve5. Lifting Eyes/ Hooks6. Two Earthing Terminals7. Diagram And Rating Plate8. Air Vent9. Explosion Vent10. 100Mm Dia Thermo Meter With Thermometer Pocket11. Four Bi Directional Plain Roller. Power Transformer 11000/433 Volts With Off Load Tap Changer – 12.5% To +2.5% In Steps Of 2.5% As Per Bis Level-2. 63 Kva 100 Kva 160 Kva 200 Kva 250 Kva 315 Kva 500 Kva 630 Kva 750/800 Kva Power Transformer (With On Load Tap Changer)Supplying Outdoor Type Copper Wound Transformer Continuously Rated For 3Ph, 50 Hz, At Full Load And Temp. Rise Not Exceeding 45 Degree C By Thermometer In Oil And 50 Degree C By The Resistance In Winding After Continuous Run At Full Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Dy11, Ht Side Connected In Delta And Lt Side Connected In Star With Neutral Brought Out Connected To Provide Separate Earthing. The Transformer Shall Have Power Terminal Arrangement, Bushing/ Cable End Box On Ht Side And Cable End Box On Lt Side. 2Nos Channels With Stoppers Shall Be Provided And Fixed On The Provided Plinth For Mounting The Transformer. The Transformer Should Have Following Standard Fittings. The Oltc Should Be Suitable For Minimum 50 Operations Per Day. Transformer Shall Be Latest Manufacturing Standards As Per Amended Is Specifications And The Load & No Load Losses Shall Be Limited To The Values Given Below Or As Per Is Or Norms Issued By Seb Which Ever Are Lower- 1. Oil Conservator With Filling Hole With Cap And Plain Oil Level Gauge.2. Silica Gel Dehydrating Breather Charged With Silica Gel.3. Oil Drain Valve4. Oil Filter Valve5. Lifting Eyes/ Hooks6. Two Earthing Terminals7. Diagram And Rating Plate8. Air Vent9. Explosion Vent10. 100Mm Dia Thermo Meter With Thermometer Pocket11. Four Bi Directional Plain Roller.12. Buchholz Relay13. Resistance Temp. Detector14. Marshalling Box15. Automatic Voltage Regulator (Avr)16. Remote Tap Changing Controller (Rtcc) Transformer 11000/433 Volts With On Load Tap Changer – 15% To +5% In Steps Of 1.25% With Rtcc, Avr And Marshalling Box And Other Specification 750/800 Kva 1000 Kva 1250 Kva 1600 Kva 2000 Kva M 1060 - Motorsfoot Mounted Motors Tefc 1500 Rpm Supplying Foot Mounted Tefc 1500 Rpm, Squirrel Cage Induction Motor, Conforming To Is 325 Having Continuous Rating Suitable For Operation At 415 Volts ± 10%, 3 Phase, 50 Hz ± 3% With “F” Class Insulation Temperature Rise Limited To Class “B” Insulation. Motors Conform To Is-12615 With Efficiency Level Ie3 And Provided With Enclosure Protection Class Ip-55. 15 Kw (20 Hp) 18.5 Kw ( 25 Hp) 22 Kw ( 30 Hp) 30 Kw ( 40 Hp) 37 Kw ( 50 Hp) 45 Kw ( 60 Hp) 55 Kw ( 75 Hp) 75 Kw ( 100 Hp) 90 Kw ( 120 Hp) 110 Kw ( 150 Hp) 132 Kw ( 180Hp ) 160 Kw ( 215 Hp ) M 1061 - Aluminium Cablecable - Aluminium Conductor Three Core, Xlpe / Pvc Insulated & Armoured Cable .Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Aluminium Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 3 Core 2.5 Sq Mm 3 Core 4 Sq Mm 3 Core 6 Sq Mm 3 Core 10 Sq Mm 3 Core 16 Sq Mm 3 Core 25 Sq Mm 3 Core 35 Sq Mm 3 Core 50 Sq Mm 3 Core 70 Sq Mm 3 Core 95 Sq Mm 3 Core 120 Sq Mm 3 Core 150 Sq Mm 3 Core 185 Sq Mm 3 Core 240 Sq Mm 3 Core 300 Sq Mm 3 Core 400 Sq Mm Ht Aluminium Three Core 3.3 Kve Cable Xlpe Insulatedsupplying Ht Aluminium Three Core Cable Xlpe Insulated ,Insulation Screened With Extruded Semi Conducting Compound In Combination With Copper Tape (0.3 Ka For 1 Sec.) Cores Laidup Inner Sheath Of Pvc Tape ,Galvanised Steel Flat Strip Armoured,And Overall Pvc Sheathed Cable Conforming To Is :7098 /Ii/85 With Latest Amendments 3 Core 70 Sq Mm 3 Core 95 Sq Mm 3 Core 120 Sq Mm 3 Core150Sq Mm 3 Core 185 Sq Mm 3 Core 240Sq Mm 3 Core 300 Sq Mm 3 Core 400 Sq Mm M 1062 - Copper Cablecable 3 Core Pvc Insulated, Pvc Sheathed Copper Conductor Flat Submersible Cable .Supplying , Flat Flexible Submersible Cable With, Copper Conductor, Pvc Insulated, And Pvc Sheathed . 3 Core 1.5 Sq Mm 3 Core 2.5 Sq Mm 3 Core 4 Sq Mm 3 Core 6 Sq Mm 3 Core 10 Sq Mm 3 Core 16 Sq Mm 3 Core 25 Sq Mm 3 Core 35 Sq Mm Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 3 Core 1.5 Sq Mm 3 Core 2.5 Sq Mm 3 Core 4 Sq M 3 Core 1.5 Sq Mm 3 Core 2.5 Sq Mm 3 Core 4 Sq Mm 3 Core 6 Sq Mm 3 Core 10 Sq Mm 3 Core 16 Sq Mm 3 Core 25 Sq Mm 3 Core 35 Sq Mm Copper Conductor Three Core, Xlpe / Pvc Insulated & Unarmoured Cable Supplying Xlpe / Pvc Insulated, Unarmoured Cable 1100 V Grade With Isi Mark Three Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner. 3 Core 1.5 Sq Mm 3 Core 2.5 Sq Mm 3 Core 4 Sq Mm 3 Core 6 Sq Mm 3 Core 10 Sq Mm 3 Core 16 Sq Mm 3 Core 25 Sq Mm 3 Core 35 Sq Mm 3 Core 50 Sq Mm 3 Core 70 Sq Mm 3 Core 95 Sq Mm Copper Conductor 3.5 Core, Xlpe / Pvc Insulated & Armoured Cable .Supplying Xlpe / Pvc Insulated, Armoured Cable 1100 V Grade With Isi Mark 3.5 Core, Solid / Stranded Copper Conductor With 6 Mm Thick 25 Mm Width M.S. Spacer With G.I. Earth Wire 6 Sq Mm, Complete In An Approved Manner 3.5 Core 25 Sq Mm 3.5 Core 35 Sq Mm 3.5 Core 50 Sq Mm 3 .5 Core 70 Sq Mm 3.5 Core 95 Sq Mm
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
47.
Drinking Water Supply and Sanitation #10015147 AOC
Tender For Emergency Works To Be Carried Out At Mhaisal Lis-Tem No.1-Replacement Of Gland Sleeve Of V.T.Pumps 8.00 Labour Charges For Replacement Of Gland Sleeve Of V.T.Pumps As Per Manufacturers Instruction Manual With All Tools, Tackles, Consumables Such As Gland Packing Etc . This Job Includes Dismatling Of Bearing Housing Assembly, Head Shaft,Reconditioning Of All Parts, Refitting Bearing Housing Assembly, Motor With Alignment Test & Trial At Mhaisal Lis. Stage I- 4 Nos. Stage Ii- 4 Nos. 42839.15 Nos. 342713.20 2.00 Labour Charges For Replacement Of Gland Sleeve Of V.T.Pumps As Per Manufacturers Instruction Manual With All Tools, Tackles, Consumables Such As Gland Packing Etc . This Job Includes Dismatling Of Bearing Housing Assembly, Head Shaft,Reconditioning Of All Parts, Refitting Bearing Housing Assembly, Motor With Alignment Test & Trial At Mhaisal Lis Stage V-2 Nos. 47905.31 Nos. 95810.62 10.00 Gland Sleeve 10464.35 Nos. 104643.50 Item No.2-Replacement Of Damaged Cooling Coil Of V.T. Pumps 2.00 Job Work Of Replacement Of Damaged Cooling Coil Of V.T. Pumps As Per Manufacturers Instruction Manual With All Tools, Tackles, Consumables Such As Gland Packing Etc.This Job Includes Dismatling Of Bearing Housing Assembly, Reconditioning Of All Parts, Refitting Bearing Housing Assembly,Motor With Alignment Test & Trial For 72 Hrs Complete . Stage I- 1 Nos. Stage Ii- 1 Nos. 42839.15 Nos. 85678.30 2.00 Job Work Of Replacement Of Damaged Cooling Coil Of V.T. Pumps As Per Manufacturers Instruction Manual With All Tools, Tackles, Consumables Such As Gland Packing Etc.This Job Includes Dismatling Of Bearing Housing Assembly, Reconditioning Of All Parts, Refitting Bearing Housing Assembly,Motor With Alignment Test & Trial For 72 Hrs Complete . Stage V- 2 Nos. 47905.31 Nos. 95810.62 4.00 Cooling Coil 80593.61 Nos. 322374.43 Item No.3-Labour Charges For Removing & Refitting Of Rubber Expansion Joint With Gasket. 37 4.00 Rej Of1000 Mm 6495.31 Nos. 25981.24 4.00 Rej Of 1200 Mm 10203.02 Nos. 40812.08 30.00 Item No.4-Fabrication & Erection Of Safety Covers For Valve Floor Openings Of Size 810 Mm X 610Mm At Mhaisal Lis Stage I . 2480.00 Nos. 74400.00 30.00 Item No.5-Fabrication & Erection Of Safety Covers For Valve Floor Openings Of Size 300 Mm X 300Mm At Mhaisal Lis Stage I . 761.00 Nos. 22830.00 33.00 Item No.6-Fabrication & Erection Of Safety Covers For Valve Floor Openings Of Size 820 Mm X 510 Mm At Mhaisal Lis Stage Ii . 2257.00 Nos. 74481.00 7 Item No.7-Supply Of Fabricated M.S. Boxes Of Size 2 M X 1 M X 1 M And Sheet 3.15Mm Thickness @ Mhaisal Stage I To V, Dongarwadi & Banewadi. 27790.00 Nos. 194530.00 Item No.8-Job Work Of Repairing Of Butterfly Valve Of 1000 Mm Dia. 10 Labour Charges For Work Of Repairing Of Butterfly Valve(1000 Mm Dia.) As Per Manufacturers Instruction Manual With All Tools, Tackles Etc. This Job Includes Labours Required For Replacing Worn Out/Damaged Spares Like End Cover, Cottor Pin, Shaft Bearing,Drive Stub Shaft Seal,Thrust Face, O Ring Etc. With Satisfactory Test & Trial Etc. P.N-1.0 & 1.6 (Excluding Spare, Lifting Charges Extra As Applicable) @ Mhaisal Stage I & Ii 25165 Nos. 251650.00 10 Labour Charges For Replacement Of Disc Retaining Ri Ng And Disc Seal Of Butterfly Valve(1000 Mm Dia.) Having Pn-1.0 And 1.6 .This Includes Removing And Dismantling Of Disc Seal , Nuts , Bolts , Sundry Material With Machining Process @ Mhaisal Stage I & Ii 28790 Nos. 287900.00 Spares For Butterfly Valve @ Mhaisal Stage I & Ii 1 Nde Shaft 26681.13 Nos. 26681.13 1 De Shaft 35058.00 Nos. 35058.00 8 Dowel Pin 539.87 Nos. 4318.96 8 Keys 1140.99 Nos. 9127.92 8 Flanged Bush 13040.01 Nos. 104320.08 10 U Seal Reataining Bush 797.97 Nos. 7979.70 10 U Seal Reataining Washer 681.19 Nos. 6811.90 10 Bearing Bush 3230.81 Nos. 32308.10 400 Item 9-Transporation Of Material / Bfv From Mhaisal Stage 1&2 Site To Nearest Midc (To And Fro) By Tata 407.( 1 Trip 50 X 2 =100 Km, Therefore For 4 Trips- 400 Km) 25.00 Km 10000.00 Item 10- Repair Work Of Pumping Machinery & Allied Mechanical Equipments @Mhaisal Stage 6A,6B & Agalgaon-Jakhapur And Old & Extended Gavan, Nagewadi & Vajrachounde Lis Etc Manufacturing, Supply, Erection, Of Steel Staircase Arrangement For Eot Crane Repair Works @ Mhaisal 6A, 6B & Agalgaon-Jakhapur Lis. 38 1395.95 Supply Of Steel Of Various Sections As Per Requirement 53.00 Kg 73985.35 1395.95 General Fabrication & Erection For Above Structures By Means Of Marking, Cutting, Welding, Handling, Labour, Workshop Charges, Sundry Material Charges, With Leads & Lifts At Site Etc Complete For Various Types Of Work 35.00 Kg 48858.25 Painting Work 54.78 Providing Supplying And Applying 1 Coat Of Red Oxide To The Steel Structure As A Primary Coat Including Cleaning, Scrubbing For Preparing The Surface To Apply Paint With All Lift Etc Complete As Directed. 199.00 Sq. Mtr 10901.22 54.78 Providing And Applying Anticorrosive Coal Tar Epoxy Paint For In Two Coats Including Surface Preparation, Chipping The Welding, Cleaning Spatters, Dust Etc. Complete As Directed. 355.00 Sq. Mtr 19446.90 Repair Of Kinetic Air Valve For All Bove Site As Per Requirements 4 Supply Of Seasoned Wood With Natural Rubber Coating Small Ball For Kav 3838.00 Nos 15352.00 4 Supply Of Seasoned Wood With Vulcanite Coating Big Ball For Kav 2424.00 Nos 9696.00 4 Seat Ring For Large Orifice Of Kav 808.00 Nos 3232.00 4 Seat Ring For Small Orifice Of Kav 505.00 Nos 2020.00 4 Labour Charges For Repalcement Of Large Orifice / Small Orifice Float, Cover Plate, Seat Ring Of Air Valve /Kinetic Air Valve (On Rising Main Only)/Tamper Proof Air Valve/Surge Supression Air Valve Having P.N -1.0 & 1.6 Rating 893.00 Nos 3572.00 1 Job Work Of Overhauling Of Hsc Pump As Per Manufacturers Instruction Manual With All Tools,Tackles Etc.This Job Includes Labour Charges,Consumables Like Gland Packing,Grease,Sundry Material Etc.This Job Includes Removal Motor From Pump,Dismantling Of All Sub Assemblies Such As Bearing,Stuffing Box,Pipings,Shaft Setc.Reconditioning Of All Parts,Inspection Of All Parts & Replace These Part Sas Per Instructions Of Concerned Authority (Spares Cost Excluded)Refitting Of All Parts & Sub Assemblies.Test & Trial Etc. 6519.00 No 6519.00 2 Job Work Of Replacement Of Damaged Bearing Of Hsc Pump With All Tools,Tackles, Consumables Such As Gland Packing,Grease Etc.This Job Includes Removing Of Motor From Pump,Dismatling Of Bearing Housing Assembly, Reconditioning Of All Parts,Refitting Bearing Housing Assembly,Motor With Test & Trial Complete 4967.00 No 9934.00 1 Job Work Of Removing Of Motor Of Hsc Pump As Per Manufacturers Manual & Refitting It On Pump With Alignment With All Tools,Tackles & Sundry Material 4364.00 No 4364.00 4 Ball Brg No.6306 For Hsc Pump For 20 Hp 914.00 No 3656.00 4 Ball Brg No.6310 For Hsc Pump For 60 Hp 2479.00 No 9916.00 4 Transportation Of All Types Of Spares, Material , Generator Set, Welding Set Required For Repairing Work At All 4 Sites 2512.00 Trips 10048.00
Contract Date: May 21, 2026 Contract Value : 24.82 Lakh
Government Departments No of Bidders 3
Maharashtra View Result →
48.
Public Administrative Department #9970764 Technical Bid
Tender For Carrying Out Minor/Repair Works Within Trimbak Municipal Council Limits.- 1 Excavation For Foundation In Earth Soil Of All Types, Sand. Gravel & Soft Murum Including Removing The Excavated Material Up To A Distance Of 50 M. Beyond The Bilding Area & Stacking And Spreading As Directed... Etc. Complete 2 Excavation For Foundation In Hard Murum Ncluding Removing The Excavated Material Up To A Distance Of 50 M. Beyond The Bilding Area & Stacking And Spreading As Directed... Etc. Complete 3 Providing Dry Trap /Grartzite/Gneiss Rubble Stone Soling 15 Cm To20Cm Thick Including Hand Packing And Compacting Complete. 4 Providing And Laying Is Situ. Cement Concrete In 1:4:8 Of Trap/ Granite/ Quartzite Genies Metal For Foundation And Bedding Including Balling Out Water Manually, For Work, Compacting Covering Newly Laid Concrete By Gunny Bag, Etc Complete (Wooden Planks / Shuttering Will Not Be All O 5 Providing And Laying Is Situ.Cement Concrete M-15 /1:2:4 Of Trap / Granite/Quartzite Genies Metal For Foundation And Bedding Including Balling Out Water Manually, Form Work ,Compacting Covering Newly Laid Concrete By Gunny Bag, Plastic Or Tarpaulin Curing Etc. Concrete ( Wooden Planks /Shuttering Will Not Be Allowed) 6 Providing And Fixing Various Sizes Of Rcc Manhole Cover (Dhape) Including Bracet & The Nacessarry Civil Work Like Making Chamber,Base, ...Etc Complete 7 Providing And Casting Situ Cement Concrete M-20 Grade Of Trap Metal For R.C.C. Slabs And Landings As Per Detailed Designs And Drawings ... Etc. Complte 8 Providing And Fixing In Position Tmt Reinforcement Of Various Diameters For R.C.C.Pile Caps Fotting Foundestion Slabs Welding And .And Supprting ....Etc Complite 9 Providing Brick Masonry In Cement Mortar 1:6 For Superstructure Including Striking Joints, Raking ....Etc Com. 10 Providing And Laying Polished Shahabad Stone Flooring 25Mm To 30 Mm Thick And Of Required Width...Etc Com. 11 Providing Internal Cement Plaster 12 Mm. Thick Insingle Coat In Cement Motar 1.5 Without Neeru Finish, To Concret, Brick Surface Curing, In All Positions ...Etc Comcomlete 12 Providing Sand Faced Plaster Externally In Cement Mortar Using Kharsalia/Kasaba Or Similar Type Of Sand, In All Positions Including Base Coat Of 15Mm Thick In C.M. 1:4 Using Waterproofing Compound At 1Kg. Per Cement Bag, ...Etccomplete Complete 13 Providing And Fixing Sintex Or Equivalent Pvc Single Leaf/Double Leaf Door Shutters Made From Infil Hollow Plastic Sections Of 200 Mm X 20 Mm With Average Wall ...Etc Complete 14 Providing And Fixing W.C. Pans (Indi Style) ...Etc Complete 15 Supplying Hard Murum At The Road Side Including Conveying And Stacking … Etc. Complete 16 Dismantling Brick Masonry In Mudand Stacking The Materials As Directed With All Leads Lifts, …. Etc. Complete Dsr. Page No- Item No. 17 Dismantling Cement Concrete Work ….. Etc Complete. 18 Dismantling R.C.C. Work & Sorting Out The Materials Such As Steel Etc. As Directed And Stacking ……Etc. Complete. 19 Providing And Fixing 60 Mm Thick Factory Made, Hydraulically Pressed; Mechanically Vibrated And Compacted Precast Intter -Locking Cement Concrete Paving Blocks In M10 Grade Of Approved Xize And Shade As Specified 50 Mm In Grey Cement And Top Surface 10 Mm In White Cement With Coloured Pigment Including Cost Of All Materials, Manufacturing Curing, Transportation Of Blocks To Work -Site Including Loding Unloding And Stacking As Directed, Layingpaving Blocks In Position Over Prepared Bed Of Sand Of 50 Mm Thixkness ... Etc. Complite 1) 60 Mm Tk In M-20 Grade 20 Providing And Fixing Heavy Duty Inter Locking Concrete Coloured Paving Blocks Of 60 Mm Thickness Factory Made, Hydraulically Pressed; Mechanically Vibrated And Compacted Precast Intter -Locking Cement Concrete Paving Blocks Of Strength 300Kg /Sqm/Cm Etc Complete 33.51/Bdm 21 Providing And Fixing Heavy Duty Inter Locking Concrete Coloured Paving Blocks Of 80 Mm Thickness Factory Made, Hydraulically Pressed; Mechanically Vibrated And Compacted Precast Intter -Locking Cement Concrete Paving Blocks Of Strength 300Kg /Sqm/Cm Etc Complete 33.52/Bdm 22 Providing And Fixing Heavy Duty Inter Locking Concrete Rubber Mould Glossy Paving Blocks Of 60 Mm Thickness Factory Made, Hydraulically Pressed; Mechanically Vibrated And Compacted Precast Intter -Locking Cement Concrete Paving Blocks Of Strength 400Kg /Sqm/Cm Etc Complete 33.53/Bdm 23 Providing And Fixing Heavy Duty Inter Locking Concrete Rubber Mould Glossy Paving Blocks Of 80 Mm Thickness Factory Made, Hydraulically Pressed; Mechanically Vibrated And Compacted Precast Intter -Locking Cement Concrete Paving Blocks Of Strength 400Kg /Sqm/Cm Etc Complete 33.54/Bdm 24 Providing And Fixing Heavy Duty Inter Locking Concrete Rubber Mould Glossy Paving Blocks Of 40 Mm Thickness Factory Made, Hydraulically Pressed; Mechanically Vibrated And Compacted Precast Intter -Locking Cement Concrete Paving Blocks Of Strength 200Kg /Sqm/Cm Etc Complete 33.55/Bdm 25 Providing Machineries Per Hr.Basis On Rent Tc. Complete. Dsr. Page No- Item No . I) J.C.B. 26 Providing Machineries Per Hr.Basis On Rent Tc. Complete. Dsr. Page No- Item No . Ii) Pocklan 27 Providing Machineries Per Hr.Basis On Rent Tc. Complete. Dsr. Page No- Item No . Ii) Tractor 28 Providing Machineries Per Hr.Basis On Rent Tc. Complete. Dsr. Page No- Item No . Ii) Crane 29 Providiing And Laying Pvc Standard Pipe As Per Required Diameter With Standard Isi Mark Company (150Mm) 30 Providiing And Laying Pvc Standard Pipe As Per Required Diameter With Standard Isi Mark Company (100Mm) 31 Providing And Laying Cast In Suti Redy Mixcement Concrete In M20 Of Trap/Granite /Quartzite/Gneiss Metal For Steps Including Steel Centering, Formwork, Laying/Pumping, Compacting, Roughening Them If Special Finish Is To Be Provided, Finishing Uneven And Honeycombed Surface And Curing Etc. Complete. 32 Providing And Laying Cast In Suti Redy Mixcement Concrete In M20 Of Trap/Granite /Quartzite/Gneiss Metal For Rcc Coumns As Per Detailed Designs And Drawing Or As Directed Including Steel Centering, Formwork, Cover Block, Laying/Pumping, Compaction Finishing The Formed Surfaces Woth Cement Mortar 1:3 Of Sufficient Minimum Thickness To Give A Smooth And Even Surface Or Roughening If Special Finish Is To Be Proveded And Curing Etc. (Page No. 220) 33 Providing And Laying Cast In Suti Redy Mixcement Concrete In M20 Of Trap/Granite /Quartzite/Gneiss Metal For Rcc Beam Lintels Per Detailed Designs And Drawing Or As Directed Including Steel Centering, Formwork, Cover Block, Laying/Pumping, Compaction Roughening The Surface If Special Finish Is To Be Provided And Curing Etc. Complete. (Page No. 221) 34 Providing And Fixing White Glazed Earthenware Lipped Flat Back/Corner Type Urinal With Pvc 5 Liters Flushing Cistern With Fittings. Inlet Pipe With Stop Tap Brackets For Fixing The Cistern, 32Mm Diameter Pvc Flush Pipe With Fitting Including Lead Soil Pipe, Lead Trap And Soil Pipe Connection Up To The Outside Face Of Wall.. (Page No. 338) 35 Providing And Fixing White Glazed Earthenware Lipped Wash Hand Basin Of 55Cm X 40 Cm Size Including Cold Water Piller Tap/Cold And Hot Water Pillar Tap Brackets, Rubbber Plugs And Brass Chain, Stop Tap And Necessary Pipe Connection Including Pvc Waste Pipe And Trap Up To The Outside Face Of The Wall Making Good The Damaged Surface Testin Etc. Complete. (Page No. 339) 36 Providing And Fixing European Type Colour Glazed Earthenware Water Closet Pan Woth Upvc Seat And Lid With Chromum Plated Brass Hinges And Rubber Buffers Including Upvc And Vent Pipe Up To The Outside Face Of Wall Without Flushing Cistern With Flush Cock And With Water Jet And Necessary Fittings Including Cutting And Making Good To The Walls And Floors Testing Etc. Complete. (Page No. 361) 37 Providing And Fixing Pvc Rain Water Pipes Of 160Mm Outer Diameter And Having Wall Thickness Of 2.2 To 2.7 Mm Confirming To I.S. 13592-1992 Including Proper Rain Water Receiving Recess With Pvc Plug, Bend, Necessary Fittings, Such As, Offsets, Shoes, Inluding Fixing The Pipe On Wall Using Approved Wooden, Etc, Complete. 38 Providing Pvc Pipes Of 50 Mm 39 Providing And Laying Concreate Pipes Of Isnp Class Of 300 Mm Diameter In Proper Line, Level And Slope Including Necessary Collars, Exavation, Laying, Fixing With Collars In Cement Mortar 1:1 And Refilling The Trench Complete 40 Providing And Construction Brick Masonry Inspection Chamber 60Cm X 45Cm X 90Cm Including 1:4:8 Cement Concrete Founation 1:2:4 Cement Concrete Channels Half Round Gsw Pipes Brick Masonry Plastering From Inside And With Frame Fixed In Cement Concrete With Rcc Cover Mendum Dury 140Kg With Frame Etc Complete 41 Providing And Construction Brick Masonry Inspection Chamber 60Cm X 45Cm X 90Cm Including 1:4:8 Cement Concrete Founation 1:2:4 Cement Concrete Channels Half Round Gsw Pipes Brick Masonry Plastering From Inside And With Frame Fixed In Cement Concrete With Rcc Cover Mendum Dury 140Kg With Frame Etc Complete 42 Providing And Construction Brick Masonry Inspection Chamber 60Cm X 45Cm X 90Cm Including 1:4:8 Cement Concrete Founation 1:2:4 Cement Concrete Channels Half Round Gsw Pipes Brick Masonry Plastering From Inside And With Frame Fixed In Cement Concrete With Rcc Cover Mendum Dury 140Kg With Frame Etc Complete 43 Providing And Fixing Rcc Cover With Frame (Heavy Duty) 90Cm X 45Cm 44 Providing Waterproof Bedding For Flooring Of Bath And Wc 25 Mm Thick In C.M.1:3 Including Using Approved Waterproofing Compound Inspecified Proportion As Per Manufacturers Specifications For Per Bag Of Cement Including Leveling, Curing And Covering 10 Years Guarante Eoncourt Fee Stamp Paper Of Rs.500/-Including Ponding Test Etc.Complete 45 Providing And Fixing Mild Steel Grillrailing 20Kg/Sq.M With Teak Wood Handrail Of Size 75Mmx60Mm. And Sill Of 75Mm.X25Mm. And Newel Posts For Staircases,Including Fabricating,Fix-Tures, Erecting, Painting The Grill Work With One Coat Ofanti-Corrosive Paint And Two Coats Of Oil Painting With Approved Colour And Polishing The Sill, Handrail And The Newel Post With French Polish. 46 Providing And Fixing Mild Steel Grill Work For Windows, Ventilator Setc. 20 Kg/Sqm As Per Drawing Including Fixtures, Necessary Welding And Painting With One Coats Of Anticorrosive Paint And Twocoatsofoilpainting Complete 47 Providing And Fixing Frame With/Without Ventilator Of Size As Specified With Country Cut Teak Wood Fo Door Sand Windows Including Chamfering, Rounding, Rebating, Iron Hold Fast Of Size 300Mmx40Mmx5Mm With Oil Painting, Etc. Complete 48 Providing And Fixingpartitions With12Mm Thick Three Layered Flat Pressed Teak Wood Particle Board Both Faces Commercial Bonded With Phenolformalde Hydesyntheticresin Including Ctw Vertical 70X70Mm And Top And Bottom Rail Of 70X35Mm And Covering Batten Of 20X10Mm At 1.00 Metre Apart On Bothways Or As Directed Including Finishing With One Coat Of Primer Complete. 49 Providing And Fixing Solid Core Flush Door Shutter In Double Leaf 32Mm Thick Decorative Type Of Exterior Grade As Per Detailed Drawings Approved Face Veneers 3Mm Thick On Both Faces Or As Directed, All Necessary Beads, Mouldings And Lipping, Wrought Iron Holdfasts, Chromium Plated Fixtures And Fastenings, With Brass Mortise Lock, Chromium Plated Handles On Both Sides, And Finishing With French Polish Etc. Complete. 50 Providing And Fixing Corrugated Galvanised Iron Sheets Of 0.63Mm Thick (24B.W.G.) For Roofing Without Wind Tiles Including Fastening With Galvanised Iron Screw Sand Bolts, Lead And Bitumen Washers As Per Drawing Etc. Complete. (Weight Of 5.5 Kg/Sq.M.). 51 Supplying, Filling, Spreading & Leveling Coarse Fine Aggregate (Naturals And/Crushed Sand Vsi Grade Finely Washed, Etc.) Of Size Range1.5Mm To 2Mm In Recharge Pit, In Required Thickness Over Gravel Layer, For All Leads & Lifts, All Complete As Per Direction Of Engineer In Charge 52 Providing Uncoursed Rubble Masonry Of Trap/Granite/Quartzite/Gneiss Stones In Cement Mortar 1:6 In Foundation And Plinth Of Innerwalls/In Plinth Of External Walls Including Bailing Out Water Manually,Striking Joints On Un Exposed Faces And Watering Etc.Complete. 53 Providing Uncoursed Rubble Masonry Of Trap/Granite/Quartzite/Gneiss Stones In Cement Mortar 1:6 In Superstructure Including Racking Out Joints When Plastering Is To Be Done/Striking Joints When No Plastering Is To Be Done On Inside Watering And Scaffolding Etc.Complete. 54 Providing Random Rubble Masonry Second Sort Of Trap/Granite/Quartzite/Gneiss Stones In Cement Mortar 1:6 In Plinth Including Bailing Out Water Manually,Striking Joints On Unexposed Faces.(Excluding Pointing) Etc.Complete. 55 Providingrandomrubblemasonrysecondsortoftrap/Granite/Quartzite/Gneissstonesincementmortar1:6Insuperstructurerackingoutjointswhenplasteringistobedone/Strikingjointswhennopointingorplasteringistobedoneontheinsidewateringandscaffolding Etc.Complete. 56 Providing Coursed Rubble Masonry Seconds Or Tof Trap/Granite/Quartzite/Gneiss Stones In Cement Mortar 1:6 In External Walls Of Plinth Including Bailing Out Water Manually, Striking Joints Inside And Raking Out Joints From Outside And Watering Etc.Complete 57 Providing Coursed Rubble Masonry Seconds Ortof Trap/Granite/Quartzite/Gneiss Stones In Cement Mortar 1:6 In Superstructure Including Raking Out Joints When Plastering Is To Be Done And Striking Joints When No Plastering Is To Be Done On The Inside, Watering Scaffolding Etc.Complete. 58 Slidingwindow-3 Track (2 Glass Shutter+1 Fly Mesh) Of Approved Make With Dgu, Providing And Fixing Of Sliding Window-3Track(2 Glass Shutter+1Fly Mesh). For Details Refer To Specifications. As Directed By Engineer In Charge. 59 Providing Rabit Material 60 Compacting The Hard Murum Side Widths Including Laying In Layers On Each Side With Vibratory Roller Including Artificial Watering Etc.Complete. 61 Providing, Laying, Spreading And Compacting Stone Aggregates Of Specific Size Sto Water Bound Macadam Specification Including Spreading In Uniform Thickness, Hand Packing To Proper Grade And Camber, Applying And Brooming Requisite Type Of Screening/Binding Materials To Fillup The Interstices Of Coarse Aggregate, Watering And Compacting With Vibratory Roller To The Required Density. By Mechanicalmeans-Gradingii (Usingscreeningtypeb(11.2Mm)Aggregate) 62 Providing And Fixing In Position Guard Railing As Per Drg.No.15Typecdt.20-4-79, With 3 Rows Of 50Mm Dia. G.I. Pipe 30Cm Apartand Fixed In M.S. Channels Of Section 125 X65X6Mm Spaced 2.5C/C1:2:4 C.C. Bedding Of Size 45X30Cm. As Per Detailed Drawing, With 3 Coats Of Approved Yellow And Black Paint Including Necessary Excavation In Any Strata. 63 Providing Stone Dust Aggregates 64 Providing And Laying In Situ/Redady Mix M-30 Controlled Cement Concrete …….Etc 65 Providing And Fixing Rcc Cover With Frame (Heavy Duty) 60Cm X 45Cm 66 Providing And Applying Two Coats Of Flat Oil Paint Of Approved Colour To Theoldstructuralsteel,K (Excluding Primer Coat) Etc. Complete. 67 Providing And Applying Two Coats Of Water Proof Cement Paint Of Approved Manufacture And Of Approved Colour To The Pla Stered Surfaces Including Scaffolding If Necessary, Cleaning And Preparing The Surface, Watering For Two Days Etc. Complete. 68 Providing And Applying Priming Coat Over New Wood And Wood Based Surfaces, Including Preparing The Surface By Thoroughly Cleaning Oil, Grease, Dirt And Other Foreign Matter, Sand Papering And Knotting, Scaffolding Etc. Complete. 69 Providing And Applying One Coat Of Seal Cement Primer Of Approved Manufacture And Shed Including Scaffolding Preparing The Surface By Cleaning Dirt And Other Foreign Matters, Scrapping If Necessary Including Scaffolding Etc. Complete. 70 Providing And Applying Pearl/Luster Finish Paint Of Approved Colour And Shade To The Existing Plaster Surface Including Scaffolding, Preparing The Surface, Applying The Acrylic Wall Putti Etc.Complete. 71 Providing And Applying Two Coats Of Exterior Acraylic Emulsion Paint Confirming To Corresponding I.S. Of Approved Manufacture And,If Necessary , And Watering The Surface For Two Days Etc Complete. 72 Providing And Applying Colour- Wash Of Approved Colour And Shade In Two Coats To New Surface Including Scaffolding, Brushing And Brooming Down(Excludingbasecoat Of White- Wash) Etc. Complete. 73 Providing And Applying Washable Powder Distemper Of Approved Colour And Shade To Old And News Urfaces In Two Coats Including Scaffolding,Preparingthesurfaces.(Excludingtheprimer Coat) Etc .Complete. 74 Providing And Applying Plastic Emulsion Paint Of Approved Quality, Colour And Shade To New Surface In Three Coats Including Scaffolding, Preparingthesurface.(Excludingprimercoat) Etc. Complete. 75 Scrapping The Old Plastered Internal Surface With Sand Paper And Coating The Entire Surface ,Etc.Completeas Directed. 76 Providing And Applying Interior Wall Finish Luster Of Approved Make On Internal Wall, Etc.Complete. 77 Providing And Applying Royale Luxury Emulsion Of Approved Make On Internal Wall Surface As Detailed , Etc.Complete. 78 Providing And Fixing Teak Wood Common Rafters, Purlins And Purlin Cleats, Hip Rafters, Jack Rafters, Ridges, Wall Plates, Post Plates And Posts For Roofing, Etc.Including Scaffolding, If Necessary All Iron Work And One Coat Of Primer Etc. Complete. 79 Providing And Fixing Shutter To Wall Cupboard Made From 19 Mm Thick Teak Particle Board With Approved Coloured Laminate D Face 1.5 Mm Thick Bonded With Phenol Formaldehyde Syntheticres In B.W.P. Grade Including Lipping Beading Iron Oxidised Fixtures And Fastening And Oil Primer Coat Etc. Complete. (Excluding Cupboard Frame). 80 Providing And Fixing 6Mm Thick Isi Mark Asbestos Cement Sheet For Roofing Including Galvanised Iron Hooks, Bolts, Galvanised Iron And Bituminous Washers,Galvanised Iron Clamps, Bolts, Nuts Including Scaffolding Etc. Complete. 81 Providing And Fixing Valley Gutter Of 22B. W. G. (0.8Mm) Plain Galvanised Iron Sheets 90Cm Wide With Teak Wood Planking 20Mm Thick Including Two Coats Of Coal-Tarringthe Upper Surface Of Plank Etc. Complete. (Excluding Painting To Underside Of Plank). 82 Providing And Fixing False Ceiling Of 10 To 12 Mm Thick Decorative Boards Of Fibrous Plaster Of Paris Including Scaffolding If Necessary All Architectural Work Like Mouldings, Cornices, Coves, Domes, Cup S Asper Detailed Drawing Sand Three Coats Of Spray Painting To Boards Etc.Complete. 83 Removing G.I. Or A.C. Sheet Roofing Including Purlins, Principal Rafters Etc. Complete. 84 Providing And Fixing In Position Gypsum Board False Ceiling With 12.5 Mm Thick Gypsum Boards, Screwed/ Fixed To The Under Structure Of Suspended G.I. Grid Constructed And Suspended From The Main Ceiling Consisting Of Ceiling Sections Of Size 25X50 Mm Maximum,Etc, Complete. 85 Providing And Fixing Single Leaf Panelled Door Shutter Without Fanlight And Shutter 35 Mm Thick As Per Drawing 86 Providing And Fixing Solid Core Flush Door Shutter In Sing Le Leaf 32Mm Thick Decorative Type Of Exterior Grade As Per Detailed Drawings Approved 87 Providing And Fixing Rolling Shutter Fabricated From Steel Laths Of Minimum Thickness 0.9Mm With Lock Plate Of 3.15Mmthick, Etc, Complete. 88 Providing And Erecting Y Type Barbed Wire Fencing With Seven Rows Of Wire With 2.45 Mm Dia G.I. Pipe , Etc. Complete. 89 Providing And Erecting 1.2 Meter High Wire Fencing With Five Rows Of Bar Bed Wire Supported On Mild Steel Angle (50X50X6Mm) Post At 2.5M C/C Including Excavation Of Pits Of Foundation Concrete Fixing The Posts In Etc.Complete 90 Providing And Erecting Chain Link Fencing 1.6 M. Height With G.I.Chain Link Of Size 50 X 50Mm, 8 Gauge Thick And Fixed 75Mm Above Ground Level Etc.Complete 91 Providing And Fixing Mild Steel Grill Railing 15 Kilogram/ Sq.M With Ghana Teak Wood Hand Rail Of Size 75Mm X 60Mm And Sill Of 75Mm.X 25Mm And Newel Posts For Stair Cases,Etc. Complete. 92 Providing And Fixing 15 Mm Dia. Screw Down Bib / Stop Tap Of Brass Including Necessary Socket Union Nut Complete. 93 Providing And Fixing 8Cm C.I. Nahani Trap Including C.I. Grating Bend And Piece Of C.I.Pipe Upto The Outside Face Of The Wall Complete. 94 Providing And Fixings Crew Down For 32Mm Dia.Wheeled Stop Tap Of Brass Including Necessary Sockets/Union Nut Complete. 95 Removing Np-2 And Np-3 Class Pipes Including Stacking At Road Side As Directed By The Engineer In Charge. Upto 900Mm Dia. Etc Complete. 96 ExecutiveS Table @ 1800Lx900Dx750Ht Providing&Fixingoftable@1800Lx900Dx750Ht, Etc, Complete. 97 Providing And Fixing 3 Seater Public Seating Chair Made Of Complete Metal With Legs In Crome Finish And Seates In Silver Powder Coating Finish, Etc Complete. 98 Provinding And Fixing Tarpaulin, Etc, Complete. 99 Conveying Materials Obtained From Road Cutting Including All Lifts, Laying In Layers Of 20Cm To 30Cm. Breaking Clods, Dressing To The Required Lines, Curves, Grades And Section, Watering And Compacting To Not Less Than 97% Of Standard Proctor Density For Alead Of Over 50M, Etc, Complete. 100 Filling In Plinth And Floors With Approved Excavated Material In 15Cm. To 20Cm. Layers Including Watering And Compacting Etc. Complete. 101 Providing And Fixing Board Displaying Information, Such As \Name Of Work, Tender Cost, Name Of Contractor, Work Completion And Liability Period Etc\ , Having Rectangular Shape Of 1.20 M X 0.90 M Size Made Up Of 4Mm Aluminum Composite Pannel Sheet With 0.5 Mm Skin Thickness Etc. Complete. 102 Providing And Laying Cement Concrete Pipe Of Is 458:2003 Np-3 Class Of 600 Mm Diameter In Proper Line, Level And Slope Etc. Complete.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 7
Maharashtra View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Maharashtra View Result →
50.
Defence #9929205 AOC
Tender For Augmentation Of Power Supply At Naval Area Visakhapatnam.; 1 Schedule A Part – I to Schedule A Part – VII:NOTE: Schedule A Part – I to Part –VII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only 2 Lumpsum price worked out by the contractor for BUILDINGS & STRUCTURES,as listed in Schedule A Part – I 3 Lumpsum price worked out by the contractor for SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION,as listed in Schedule A Part – II 4 Lumpsum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Schedule A Part – III 5 Lumpsum price worked out by the contractor for INTERNAL WATER SUPPLY, as listed in Schedule A Part – IV 6 Lumpsum price worked out by the contractor for SEWAGE DISPOSAL,as listed in Schedule A Part – V 7 Lumpsum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Schedule A Part – VI 8 Lumpsum price worked out by the contractor for LIGHTENING PROTECTION ,as listed in Schedule A Part – VII 9 Schedule A Part - VIII: (Miscellaneous Items) ( Internal Electrification, Internal water supply, External Electrification, Site clearance & Area development, Lightening Protection and AC & Ref) 10 Internal Electrification 11 M&L for Ponit wiring with 1.5 sqmmPVC insulated and unsheathed copper conductorcable multistranded 1100 Volts grade, FRLS, ISI marked drawn through and inculding non metallic PVC rigid concealed conduit and conduit accessories, medium grade, ISI marked, concealed to wall or surface mounted on pillars/columns including provn of box type switchboard consisting of pre fabricated pressed steel terminal box of suitable size made out of 1.2 mm thick sheets,for mounting modular brackets,with and including modular brackets and switch plates as required at site for fixing modular type switches, sockets etc inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable for earth continuity green in colour, connected to earth duly complete all as specified and directed forOne light/ exhaust fan/ fanpoint controlled by one switch :-Note: (a) The PVC conduit shall be concealed and switch boards shall be flush to wall. (b) On columns/ pillars the box type switchboards surface mounted with necessary PVC conduit upto ceiling/nearest junction tapping shall be surface type conduitand quoted rate deemed to be inclusive for the same.(c) The quoted rate inclsuive necessary modules any type as per requirement incl all accessories complete 12 All as per item No. 10 abovebut one light point controlled by two Nos of two way switch complete all as specefied and directed. 13 All as per item No.10 above but One3 pin socket outlet 05 amps socket on independent board with 1.5 sqmm FRLS PVC wire for phase and neutral and one run of 1.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 14 All as per item No.10 above but One3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm FRLS PVC wire for phase and neutral and one run of 2.5 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 15 All as per item No. 10 above but for one geycer/AC point with 4.0 sqmm FRLS PVC wire for phase and neutral and one run of 4 sqmm copper cable green in colourfor earth continuty conductor complete all as specefied and directed. 16 S&Fexhaust fan, steel body AC single Phase. 230 V of size 450mm sweep with, blades, and frame and louvers fixed on wall making opening, fixing and making good the distrubed surfaces etccomplete with and inclussive of making necessary electric connection from ceiling rose to fan through 1 sqmm twin core flexible wire all as spcified and as directed. 17 S&FLED tube light fitting, batten type,poly carbonate body, 20Watt fitting with all accessories, internally prewired and connecting up with with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. 18 S&FLED light fitting, batten type,suspended LED aluminium profile lights cool white 36 watt length 1200mm including all connections, hanging strings complete all as specified and directed. 19 S&FLED bay light fitting 70 Watt 230V AC indoor type with thermal management in multiple optics and industrial type and corrosion resistant complete with driver and lamp complete all as specified and directed. 20 S&FLED flood light fitting 210 Watt 230V AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. 21 S&F LED bldg Security light fitting 35 Watt, 230AC out door type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 ptoction complete all accessories including 1.5sqmm weather proof 3 core FRLS grade copper conductor to fitting including 32mm dia medium grade1.5 m long GI pipe for fixing of street lights, bend to shape for fixing on wall/pole withsuitable MS brackets nuts and bolts etccompelte all as specified and as directred. 22 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x2.5 sqmm for phase and neutral duly colour coded and 1x2.5 sqmm for earth continuity conductor green in colour complete all as specified and as directed.( for SPN DB to board and submain wiring of building security light)Note :(i) Two run of 2.5 Sqmm + one run of 2.5 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 23 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 2x4 sqmm for phase and neutral duly colour coded and 1x4 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) Two run of 4 Sqmm + one run of 4 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 24 M&L for submain wiring complete with earth wire of PVC insulated multistranded copper conductor FRLS cable, ISI marked with and inclussive of suitable size PVC rigid counduit concealed to wall/roof, and PVC wire of size 4x10 sqmm for phase and neutral duly colour coded and 1x10 sqmm for earth continuity conductor green in colour complete all as specified and as directed.Note :(i) four run of 10 Sqmm + one run of 10 Sqmm as a earth wire cable + one run of PVC conduitshall be measured as an one Unit. 25 S&F VTPN MCCB DB 4 way 12 outgoing having powder coated sheet steel enclosure fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 26 S&F TPN DB 4 way 12 outgoing having powder coated sheet steel enclosure double door fitted with bus bar, DIN channel & neutral link & earth link complete all as specefied and directed. 27 M&L for earthing complete with GI steel plate electrode 600x600x6 mm, burried directly in ground (earth pit not less than 2.25 m deep below ground level)with top edge of the plate not less than 1.5 m below normal groundlevel, connected to GI wire 4 mm dia (upto 7.5M in length from earth plate) by means of bolts, nuts, check nuts and washers of GI all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipelight grade for watering pipe and 32 mm bore GI light grade for earth lead protection pipe connected upto DBs, and suitable CI top cover with handle, funnel, strainer,charcoal, salt and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC workcomplete all as specefied and directed.Note: GI earth wire upto 7.5 m shall be deemed to be included in the quoted lumpsum and beyond 7.5 m shall be measured and paid separately under relavent item. 28 Internal Water Supply 29 S&F Bib taps two way, cast copper alloy fancy typechromium plated with crutch or butterfly handle, screwed down for size of15 mm inner dia, suitable fo 16 mm outer dia CPVC pipes complete all as specified and as directed. Make:- Jaquar cat No. OPP-15041PM or equivalent 30 SITE CLEARANCE / AREA DEVELOPMENT/EARTH WORK/EXCAVATION 31 M&L for cleaning jungle incl uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm and removal of rubbish upto a distance of 50 m outside the pheiphery of the area cleared all as specified and as directed. 32 External Electrification 33 Supply, Installation, Testing and Commissioning of Copper wound Power transformer step down outdoor type 132/33 KV, capacity16 MVA(suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Star/star (YNyn0) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with terminal arrangement of HV Outdoor Bushings/LV Bushing and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relay & Oil Surge Relayd) NCT on EHV and HV sidee) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Sealingh) Breatherj) Aircell in conservator tankk) Radiators and control valvesl) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomm) motor operated OLTC shall be n) On load tap changing with RTCC panelo) Marshalling boxp) Thermosphyn filter 34 q) Terminal Connectorsr) Direct solid earthing both HV side and LV sides) Name Plate (Rating, Diagram and Valve Plates)t) Metallic enclosed NGR as per OEMu) NIFPS to be installed by OEMTransformer rating plate shall contain the information as given in IS-2026 (Part-I).Makes: Bharat Bijlee/Crompton Greaves / Schneider / Siemens 35 Note : a) PCC foundation and mounting rails, all civil work, etc and general works which are required as per site/technically required to achieve optimum efficency of the transformer are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted.b)Size of plinth, PCC, Rail size etc shall be as per OEM recommendation.c) Technical drgs of the transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch.d) pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.e) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test) 36 f)Full Type Test Reports of at least the followings must be submitted: -1. 132/33 kV Power Transformer for same capacity or higher2. Tap Changer3. Buchholz Relay4. Pressure Relief valve5. Oil Surge Relay6. Temperature rise test7. Impulse test 8. Load and No load loss 37 Supply, install, test and commission lightning arrestor single pole made of polymer , heavy duty station class, gapless, zinc oxide type (non linear) fitted with pressure relief device, arc diverting ports, grading/corona rings, discharge counter with ammeter, mounting insulator complete all as specified and as per IS 3070 (Part I) and with following parameters:- Nominal system voltage : 132 KVNormal discharge current rating : 10 KA .Note- The cost of Galvanised Iron lattice structure including foundation (as Per OEM) is deemed to be included in the Quoted rate 38 Supply, Installation, Testing and Commissioning of cable XLPE insulated, armoured, 132 KV grade (E) copper conductor UG cable, laid in trenches/on structures/in cable duct horizontally or in tier formation as per site condition complete all as per IS specifications of size. 1 C x 630 sqmm. The cable shall be of EHV grade single core, armoured stranded compacted circular Copper conductor of cross section 630 sq.mm, core screening by a layer of semiconducting tape followed by a layer of semiconducting compound, cross linked polyethylene (XLPE) dry cured insulation, insulation screening with semiconducting compound extruded directly over the insulation, longitudinal sealing by a layer of non woven tape with water swellable absorbent over insulation screen, followed by radial sealing of corrugated & seamless or seam welded aluminum with asphalt coating & overall PE sheathed & graphite coated/semi conducting layer and conforming to the technical particulars of specification.IS 7098 part 3 shall be followed for manufacturing of cable along with technical specification. Makes: Universal/ KEI /RPG/CCI.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. 39 Supply, lay, connect, test and commission multi core copper conductor cables, PVC insulated, LT 1100 volts grade GI strip/wire armoured in ducts/on structuresincluding clamps, terminations on both ends with glands and connecting up to the equipment all as specified and of following sizes:- 40 4 core 1.5 sqmm 41 4 core 2.5 sqmm 42 6 core 2.5 sqmm 43 6 core 4 sqmm 44 Supply and fix GI cable tray perforated on walls/MS angle iron supportsof depth 100mm following widths including bends, coupler plates complete all as specified.Note: Angle iron used for fixing cable trays will be measued and paid separately. 45 200 mm width 46 300 mm width 47 Material and labour for provision of earthmat laid in trenches/ ducts/ walls made of following sizes of GI strips including jointing by means of brazing complete all as specified :- 48 GI 100 x 10 mm 49 GI 75 x 10 mm 50 GI 50 x 6 mm 51 GI 32 x 6 mm 52 Supply and fix earth strip following sizes laid in trench/ floor/ walls including jointing by means of brazing complete all as specified :- 53 100 x 10 mm copper strip 54 50 x 6 mm copper strip 55 32 x 6 mm copper strip 56 Supply, installing, testing and commissioning of CPRI approved LT panel board, cubical indoor type, fabricated out of 2.00 mm thick CRCA sheet with angle iron frame made of 50 x 50 x 6mm at vertical corners & medium channel at base of panel board floor mounted, dust and vermin proof, with busbar 200 Amps suitable for voltage 415 V 3 phase 4 wire weather proof, with separate hinge door for each compartment with locking arrangement, with back door common openable (screwed), groutedin PCC 1:2:4 complete incl painting the steel surfaces with two coats of zinc chromate primer & two coats of epxoy paint suitable for installation in coastal areas and incl of suitable size aluminium busbar (TPN), suitable cable glands, LED Indicating lamps and incl provn of the following:- 57 (i) 4 Pole MCCB 25 KA 100 A - 1 Nos (I/C)(ii) 4 Pole MCCB 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 03 No (iii) 4 Pole MCCB 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (iv) 4 Pole MCCB 25Amp, 50 Hz, 415 V with rupturing capacity 25 KA - 02 No (v) Digital voltmeter with selector switch - 1 No (vi) Digital ammeter with CTs & selector switch - 1 No (vii) LED indicating lamps - 8 sets (3 lamps/set) 58 Supply and lay in trenches HDPE pipe Double wall corrugated 200 mm dia with integral socketsfor cable protection including necessary collars, earth work and sealing at both ends with bitumen compound complete all as specified. 59 Supply, lay, connect, test and commission cable LT 1100 volts heavy duty XLPE insulated armoured aluminium conductors, in trenches/ ducts on angle iron supports including glanding, crimping and connecting up complete all as specified and of following sizes:- 60 3.5 Core x 95 sqmm 61 4 Core x 25 sqmm 62 Supply, Installation, Testing and Commissioning Earthing complete with Galvanised Iron plate electrode 600x600x6 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to GI earth strip 32 x 6 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 40 mm dia light grade GI pipe all as specified and directed and tested on completion. 63 Supply, Installation, Testing and Commissioning Earthing complete with copper earth plate electrode 600x600x3 mm thick buried directly in ground(earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper earth strip 25 x 3 mm by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including Charcoal and rock salt with necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber Hinged to CI frame with MS bar 6mm dia 150mm c/c reinforcement, watering funnel with 15 mm dia medium grade for watering and for protection of earth electrode 32 mm dia light grade GI pipe all as specified and directed and tested on completion. 64 Boring of holes under road, pavement, hard standing by trenches by trenchless technologyas per site conditions using ultra sound technique and necessary machinery complete all as specified 65 depth of trench varying between 2 to 4 meters 66 depth of trench varying between 4 to 7 meters 67 Supply, Installation, Testing and commissioning ofindoor, metal enclosed corrosion proof aluminium alloy gas insulated switchgear 145 KV 3Phase 50 HZ, 2500 Amps, Three phase encapsulated consisting of2 nos outgoing transformer bay in either side of the existing GIS (Siemens) including installation tools, spares, refill kits all as specified. Makes: ABB/CG/GE/SIEMENS 68 Each Transformer feeder bay consists of the following: 2Nosa) Circuit breaker SF6 insulated 145 KV 2500 A 3 pole with short circuit current with stand capacity of 40 KA for 3 sec - 1 No.b) Disconnector cum earthing switch SF6 insulated, 145 KV 2500 A 3 pole motor operated - 2 sets.1 set on Bus side and 1 set on line side.c) Fast acting earth switch SF6 insulated 145 KV motor operated - 1 sets. d) Current transformer 145 KV 300-150/5+5+5 with Core 1:class 0.2, 15 VA , Core 2 : 5P20, Core 3 : PS class, 15 VA respectively - 1 Set (Three Nos).e) Three phase Voltage transformer 0.2 class accuracy, 10 VA burden,145 KV, 132 KV/√3/110V/√3 - 1 set.f) Lightning arrestor gapless type metal zinc oxide type 120 KV rms 10 KA including discharge counter and leakage current meter.g) Bus bars 145 KV 2500 Amps 3Ø - required as per scheme.h) Cable end box suitable for 132 KV system - 1 No.j) Local control panel- 1 No. 69 Note : The GIS system offered by the bidder shall be designed, manufactured, assembled and tested in accordance with the IEC 62271-203 for switch gear and other relevant IEC andfor balance materials as mentioned in PS. The GIS Outgoing bays are to be installed with the existing GIS extension (Siemens Make ) interface in either sides of the setup. Bidder has to supply the following items along with GIS system and costis deemed to be included in GIS system. Civil foundation / mounting rails, all civil work, etc and general works which if required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. Erection & commissioing shall be under OEM recommendation and supervision. The earth connection from GIS euipment to earth grid/matt as per OEM recomendation and the cost of same is deemed to be included in the unit price. Technical drgs of the GIS module submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the GIS module to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of GIS module shall be carried out by Senior Electrical Inspector / Electrical Inspector. 70 a) Local control cubicles.b) Gas handling equipment for draining and refilling of each compartment of GIS including filtration and purification equipment and vacuum pump. c) SF6 gas sufficient for first filling of entire switch gear including usual losses during commissioning.d)1 Bottles (40 Kg each) of SF6 gas in non returnable vessels. e)Gas leakage detectors.f) Gas Purity Tester for air content and moisture content in SF6 gas. g)Special tool and tackles for erection operation and maintenance of GIS h)Mandatory spares and tools ( Aux contact ( for CB, Busbar disconnector), Motor for CB drive (DS-ES drive), Bursting Disc, Adsorber, Density Monitor for CB, Tripping coil, Closing Coil. - 01 set Each.(i) Bay control unit. 71 Supply, Installation, Testing and Commissioning of control and relay simplex type panel with front swing & front perplex glass door RAL7035 natural IP 32 ventilation for 132/33 KV transformers protection consisting of the following: 72 a) Numerical Transformer Differential Protection Relay Make- ABB/Siemens – 1nob) Numerical Backup Protection Relay of Make - ABB/Siemens – 1noc) Tri Vector Meter - Secure make Premier 300 or Equivalent- with ABT & RS485 (modbus) port, RJ 45 port Accuracy class 0.2S- 2nod) Auxiliary Relay - with self-reset contacts. Operating time<20ms. (4 Contacts) of Make ABB/Siemens – 5nose) DC/ACSupply Supervision-200ms 73 Supply, Installation, Testing and Commissioning of 145KV 630A 40KAOil filled outdoor termination with composite insulator, solid rod connector bolt and support insulators for cables with XLPE insulation. The termination base plate and the cables metallic sheath shall be electrically insulated from the supporting structure by means of self-supporting stand-off insulators or any other self-supporting means designed to withstand both mechanical and electrical stresses in services. The stress cone shall inhibit possible mechanical stress and deformation of the cable insulation surface during operation and also shall be capable of accommodating minor radial and longitudinal movement without determent to the dielectric stress in the insulation shield. The termination shall be within polymeric or porcelain hollow insulator in brown or grey colour as perstandard practice of manufacturing in addition upon, arcing horn and shield ring shall have to be supplied wherever required. The termination shall be filled with an insulating compound up to a level where the electric field is substantially reduced and shall be offered. Oil filled termination should have silicon oil as di-electric medium. Silicon oil should not be subject to any heating at site prior to filling. The outdoor terminal should be suitable for very heavily polluted atmospheric conditions with total creepage distance of 31 mm/ kV and protected creepage distance of not more than 50% of the total Creepage distance. The cable end terminals for terminating the cables shall be fully compatible with the cables to be supplied. Civil foundation / Supporting Strcuture etc and general works which are required as per site/technically required to achieve optimum efficency are to be supplied by the contractor for which rate is deemed to be included in the unit rate quoted. 74 Supply, Installation, Testing and Commissioning of 145kV Dry type GIS termination suitable for XLPE 132 KV IC x 630 sqmm including necessary accessories , fixtures and fittings of complete installation etc complete all a specified and directed.Indoor Termination at GIS SF6 Housing It shall be dry type without insulating oil. There shall be mechanical devices to maintain the interface pressure if requires. It shall be based on the EPR (Ethylene-Propylene Rubber)- based or silicon based stress relief cone. Termination shall be dry type without insulating oil. Stress relief cone and mechanical devices shall be designed to fit with controlled interference over the cable insulation and shall follow the cables diameter variations still guaranteeing under any service condition a sufficient positive pressure to control the electric field concentration. Plug-in type leading conductors shall be supplied though at the time of detailed engineering confirmation shall be given for selection of normal type, blind type or plug-in type. Design and scope of delivery shall be fully complying with IEC-60859, IEC-62271-209 and possibly adjusted the various needs of project. The main insulation components shall be fully examined and tested in the factory.For cable Termination purpose only certified (certification from cable accessories manufacturer ) personnel shall be employed. Make: Raychem or Equivalent 75 Supply, Installation, testing & commissioning ofHT 33KV VCB line up of Six panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 3Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 76 A. INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories :-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5 A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out TypeResin cast Ratio : 33KV/√3/110V/√350VA, CLASS: 0.5-3 Nos.f.12 Window Annunciatorg.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 87C (differential P) and 64 (Restricted earth fault) .Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 77 B. OUTGOING - 3 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motorb.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core-3 : PS class- 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS), 64 (Restricted earth fault).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 78 C. BUS COUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay with all protection.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 79 Supply, Installation, Testing and Commissioning of Three Phase 4Wire 110V/50A FCBC Thristor based with in-built DCDB and RS485 communicationsuitable for 110V/200AH VRLA battery with 55 Cellsin complete as specified and directed. Make: Amararaja/Exide 80 Supply, installation, testing and commissioning of cable 3 Core 300 Sq.mm 33KV(E) XLPE cable grade cable of size suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, as amended upto date with ISI marked of following sizes in VCV manufacturing process.Note- Technical details of the cable submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the cable to be inspected by the rep of accepting officer at Factory premises as per IS before despatch 81 S&F of Cable jointing kit for 33 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 300 Sqmm 3 core complete all as specified and directed. 82 S&F of Cable jointing kit for3 Core 300 Sq.mm 33 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 83 S&F of Cable jointing kit for 3 Core 300 Sq.mm 33 KV grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable complete all as specified and directed. 84 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded aluminium conductor shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of following sizes in VCV manufacturing process. 85 3 Core 240 Sq.mm 86 3 Core 400 Sq.mm 87 Supply, laying & testing of 11KV(E)XLPE insulated cable of following sizes suitable for earthed system having compacted circular stranded copper conductor 1 core 1000 sqmm shielded with semi-conducting compound extruded layer XLPE insulated dry cured core shielded with semi-conducting compound extruded layer followed by metallic copper foil, screened inner sheath of extruded PVC, galvanized single flat steel strip armoured and PVC sheathed overall conforming to IS: 7098/Part-II/1985, asamended upto date with ISI marked of VCV manufacturing process. 88 S&F for Cable jointing kit for 11 KV grade cable for Outdoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 89 S&F for Cable jointing kit for 11 KV grade cable for Indoor End termination kit heat shrink type joint complete with jointing material and accessories suitable for 1 core 1000 sqmm XLPE armoured copper conductor cable sqmm etc complete all as specified and directed. 90 S&F for Cable jointing kit for 11 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm etc complete all as specified and directed. 91 S&F of Cable jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of following sizes etc. complete all as specified and directed. 92 3 Core 240 Sq.mm 93 3 Core 400 Sq.mm 94 Design, Supply, Installation, Testing and Commissioning of GSM based energy management system/ substation automation system with suitable software capable of taking care of complete data monitoring, data logging and control functions at 132 MRS consisting of 2 Nos 132 KV GIS, 6 Nos HT 33 KV VCBs at MRS , 7 Nos 33 KV VCBs at NSB Substation, 8 Nos 11 KV VCBs at NSB and other allied switchgears at 33/11 KV substation at DH complete with servers, work stations, desk top computers, operating system, communication products and object softwares assembled from industry standard products all as specified 95 a) BCU suitable for substation automation.b) Integration with Existing Scada server.c) Fibre/Eithernet switch (for station level & bay level) -8 sets.d) RTU (with redundant RTU , Power Supply & Hot Swappable IO configuration) - 2 set.e) SCADA software.f) Suitable Modems & ALUs.h) Integration with Existing central SCADA software- 1 set.Note- a) The SCADA system is GSM based and to be integrated with existing SCADA server. b) The cost of Connecting cable (e.g-Optical fibre cable Network, CAT 6 cable Armoured/unarmoured etc) and accessories for integration of IED, Ethernet and RTU, ALU, IED (Relay) as required at site is deemed to be included in the unit price. c) Technical drgs of the SCADA submitted by the contractor is required to be approved by the accepting officer before taking procurement action . 96 Supply and fixing in position Retardant/ extinguishing electric insulated synthetic mat2.5 mm (+/-) 10% thick conforming to BIS -DOC No ET-02 (540) dt 30/04/2004, meeting requirements of IS- 3043, IS-5216 (Part-1, 2 & 3), IS-15652:2006 and IEC 479 Pub-I tested having minimum width of 1000 mm (+/-) 20 mm. All allied materials such as PU-Resin Chemical bond (hardener), special PVC adhesive liquid primer and qty required to complete the job as per site requirement suitable for all voltages not exceeding 33/11 KV system complete all as specified. 97 M&L for RCC cable route indicator semi-circular shape on top of size 600x450x100 mm casted in PCC 1:3:6with TMT bar of size 10 mm dia and foundation base casted in RCC 1:2:4, grouted in earth upto 550 mm duly engraved the following letters HT UG CABLEwith two coats of antifungal weather coat paint, etc all as specified and directed. 98 S & F for Display chart (set of 2 nos) of size 6 x 4 duly made on white polyvinyl sheet exactly showing the locations of the yard and the machineries and equipments installed in the sub-station duly marked properly with legends etc, and a separate chart showing the details of machineries installed with nos, capacity/ rating and make with computer cutting letters of approved size on poly vinyl sheet all as specified and directed. 99 S&F for Display chart (set of 2 nos) of size 4 x 5 duly made on white polyvinyl sheet exactly showing the lay out of transmission and distribution of HT UG cable routes, locations of the HT Joints, drawn on autocad, etc duly marked properly with legends, with computer cutting letters of approved size on poly vinyl sheet, all as specified and directed. 100 S & F for shock treatment chartof size 1.5 m x 1.5 m x 0.025 m duly laminated with wooden frame (tick wood)enclosure all as specified and fixed in position as directed by Engineer-in-charge. 101 S & F First aid GI box containing prescribed medicines for first aid box as per standard quality and quantity each as required to provide first aid treatment in an emergency complete all as specified 102 Supply, Installation, Testing and Commissioning of Power transformer step down outdoor type 33/11 KV, capacity 16 MVA (suitable for 10/16MVA cooling), ONAN/ONAF, Vector group Delta/star (Dyn11) with on load tap changing gear (+) 5% to (-)15% in steps of 1.25% on HV side, with HV/LV Cable Box and all standard accessories as per IS 2026 and as specified in PS, including first fill of oil complete comprising the following accessories:-a)Conservator Tankb) Pressure Relief Devicec) Buchholz Relayd) Oil Surge Relaye) Oil Temperature Indicator (OTI)f) Winding Temperature Indicator (WTI)g) Oil Preservation Equipment likeh) Oil Sealingj) Breatherk) Aircell in conservator tankl) Radiators and control valvesm) Each radiator tank shall have its own cooling fans, shut off valves at the top and bottomn) motor operated OLTC shall be o) On load tap changing with RTCC panelp) Marshalling boxq) Thermosphyn filterr) NIFPS to be installed By OEM 103 Note- i) Technical drgs of the Transformer alongwith NIFPS submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at various stages at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector.ii) The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform of transformer as per OEM recommendations and finishing the top surface even and smooth.iii) Manufacturer shall possess NABL accredited test lab for electrical testing(Routine test, type test and special test.iv) Type test reports of33/11 KV Transformer of same capacity or higher Such as Temperature rise, Impulse test, Short circuit test , Vacuum Tests of Tank & Radiator, No Load & Load Loss test and tap changer to be submitted by the bidder during Drawing approval 104 Supplying, Installing, Connecting, Commissioning and Testing of Transformer, Step Down, Outdoor Type, Floor or Platform Mounted complete with standard fittings, 33 KV / 433 V [at No load], AC, 3 Phase, 50 Hz, of 100 KVA capacity, Double Copper Wound, K class Natural Ester Oil immersed, CRGO Core type Naturally cooled, Built-up with class A insulation, having Primary Voltage [HT] 33 KV and Secondary Voltage [LT] of 433 Volts, Delta connected on 33 KV Side & Star connected on 433 Volts side, designed & constructed with particular reference to Tropical Condition, conforming to IS – 1180-2014, including PCC / Brick Masonry Foundation / Platform as per IE Rules, fixing HT / LT Busbar and Cables etc. complete all as specified and as directed andcomprising of the following Specification and Fittings:Continuous Rating: 100 KVANo-Load Voltage Ratio : 33 KV / 433 V Tapping on HV[%]: ± 7.5, ± 5, ± 2.5Phase & Frequency : 3 Phase & 50 HzConnection: Delta StarVector Group : DYN 11Cooling : KNANType: OutdoorNote: The rate quoted is deemed to include the cost of PCC / Brick Masonry Foundation / Platform as per OEM recommendations and finishing the top surface even and smooth complete all as per manufacturer’s recommendations, as specified and as directed. 105 Fittings:[a] Externally hand operated Off–Circuit Tap Switch with position indicator and locking device.[b] Conservator with Oil Gauge, filling hole with plug & drain hole with plug[c] Undercarriage with four plain rollers[d] Oil filling hole cum air release plug[e] Drain Valve cum Sampling Valve[f] Top Filter Valve with Plug[g] Rating Plate with Diagram Plate[h] Lifting lugs for Transformer[j] Lifting lugs for Core[k] Earthing Terminals[l] Thermometer Pockets[m] Silica Gel Breather[n] Explosion Vent[o] Marshalling Box with Double Window[p] OCTC.Note- Technical drgs of the Transformer submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the Transformer to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of Transformer shall be carried out by Senior Electrical Inspector / Electrical Inspector. 106 Supply, Installation, testing & commissioning ofHT 33KV VCB line up Seven panels switchboard consisting of 1250A, VCB 33 KV - 2Nos as incomer with Bus coupler cum Bus Riser 1250A VCB 33 KV-1 No with 1250A VCB 33 KV- 4Nos as outgoing.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2 & C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete all as specified and as directed.Make: ABB /CG / Schneider / Siemens. 107 A INCOMER-2 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories .a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5 Core-1: 15VA Class 0.5, Core -2 5P20 - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 33KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,k. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS) and 64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 108 B. OUTGOING - 4 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-200/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Transformer Differential Protecton (except Stn Transformer )64 (Restricted earth fault) Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 109 C. BUSCOUPLER- 1 Nos ( Each consisting of )33kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking.f. Numerical Protection Relay.g. ABT scheme with Manual Option.Note:The above said panelsEarthing truck -01 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation.Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panel to be inspected by the rep of accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panel shall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 110 Supply, Installation, testing & commissioning ofHT 11KV, 25 kA, VCB line of Nine panels switchboard consisting of 1250 Amps, VCB 11 KV - 02 Nos as Incomer, Bus coupler 1250Amps VCB 11 KV -1Nos , Outoing 1250AVCB 11 KV- 6 Nos.VCB panel indoortype totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontalisolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated should be used. The switchgear panel shall be of sheet steel constructionnot less than 2.5mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2duty. The manufacturer of circuit breaker & Panel shall also be the manufacturer of the Vacuum Interrupter, Relay. The switchgear and control gear panels shall be of the fully arc proof for 25 kA for 1Sec AFLR complete Make: ABB /CG / Schneider / Siemens. 111 A. INCOMER-2 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories:-a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 800-600-400/5+5+5A Core-1: 15VA Class 0.5, Core -2 5P20, Core -3: Class PS - 3nos.e. Potential Transformer Draw out Type Resin cast Ratio : 11KV/√3/110V/√3100VA, CLASS: 0.5-3 Nos.f.12 Window Annunciator.g.Digital Ammeter with ASS.h.Digital Voltmeter with VSS.i.Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.j.Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,l. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS),Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 112 B. OUTGOING - 6 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Current Transformer Indoor Single Phase Resin Cast Ratio: 400-300-200/5-5A Core-1: 15VA Class 0.5, Core -2 5P20 - 3 nos.e.12 Window Annunciator.f.Digital Ammeter with ASS.g. Digital Voltmeter with VSS.h. Multifunction Load Manager Class 0.5 with RS485 & Ethernet communication.i. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,j. Numerical Protection IEC 61850 Draw out Relay with Graphical display- 1nowith Three Phase O/C & E/F (50, 51, 50N, 51N, 50G, 51G),Three Phase Directional O/C & E/F (67/67N), Negative Phase Sequence O/C (46) ,Inrush Detection (68), Circuit Breaker Failure Protection (50BF), Broken Conductor (46BC), Three Phase O/V, U/V & NDR (27, 59, 59N) ,Thermal Overload (49),Negative Sequence Overvoltage (47) ,Reverse Power (32),Over Frequency (81O), Under Frequency (81U), CT Supervision (60 CTS) ,VT Fuse Failure (60 VTS).Relay shall have 8 DI and 8 DO. Makes: ABB/CG/Schneider/Siemens. 113 C. BUSCOUPLER- 1 Nos ( Each consisting of )11kVIndoorSwitchgear Panel consisting of Breaker-1250A, 25kA draw out type having following accessories for Transformer Outgoing.a. 230VAC Spring Charge Motor.b.110VDC Closing Coil.c.110VDC Shunt Trip Coil.d. Master Trip Relay, TCS Relay , TNC Lockable Type, Manual/Remote Selector Swithc etc.,e. Electrical & Mechanical Interlocking, ABT scheme with Manual option.Note: The above said panelsEarthing truck -02 nos. Separate earthing truckfor bus earthing & cable earthing. Earthing truck shall be so designed that it is impossible to earth alive. It shall be provided with capacitive voltage detection with audio visual annunciation. Technical drgs of the VCB panel submitted by the contractor is required to be approved by the accepting officer before taking procurement action and the VCB panelto be inspected by rep of the accepting officer at Factory premises as per IS before despatch. Pre-commissioning inspection of VCB panelshall be carried out by Senior Electrical Inspector / Electrical Inspector. The VCB panel should be GSM based SCADA compatible. 114 Supply, install, test and commission of APFC panel indoor type 1500 KVAR 12.1 KV, complete Make : CG / Shreem /Siemens /BCH.Capacitor panel consisting of below:-83.33 KVAR, 6.98 KV, externally fused capacitor unit for 250K @12.1KV (207K 11KV) step - 12nos.166.67 KVAR, 6.98 KV, externally fused capacitor unit for 500K @12.11 KV (413K 11KV) step - 3nos.11 KV, Air core dry type, class F aluminium wound, 1Ph, 0.2%, series reactor (STC shall be 16.6 times rated current for 2 sec) - 15nos.11KV, 400A, 10KA for 1 Sec, 3 phase vacuum contactor - 15nos.11 KV/110V-190V, 50-50VA, 3Ф resin cast RVT - 1no.11 KV HT HRC fuses of suitable current rating- 15nos.11 KV, 630Amp, 25KA for 1 sec, off load type isolator- 1no.3PH, RC surge suppressor- 1no.APFC relay (RS485/232 communication port)- 1no.Control cable, space heater, timer, thermostat, CFL lamp, LED indication, push button, selector switch, terminal connectors, gasket, limit switch, name plate, hardware - 1 set. 115 S& F spring loaded aluminium clamps suitable for HV & EHV cables of following sizes inculding all necessary items to fix such as nuts, bolts, washers etc. and all fixing arrangements as required at site. 116 Single core 630 Sqmm 132 KV Al cable 117 Three core 300 Sqmm 33 KV Al cable 118 M & L for survey, site inspection, layout design and location identification for complete earthing/earth mat layouting for best result depending on the soil condition at the site of 132KV and 33 KV yard all complete as specified and directed. Survey report alongwith layout drawing in A3 size properly verified by a Engineer to be submitted in triplicate for approval of Engr in charge/GE 119 Material and labour for brick massonary in cement mortar 1:4 of internal size 1000 x 1000 x 800mm for man hole in contol/power cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 120 Material and labour for brick massonary in cement mortar 1:4 of internal size 1500 x 1500 x 1400mm for man hole in control cable routes including plastering with cement mortar 1:6 10MM thick internally and externally 150mm below the G.L. with 1:6 cement mortar 15mm thick,PCC 1:4:8type D2 by using 40mm gradded aggregate foundation of size 1550x1550 mm of 150mm thick and PCC 1:3:6 for coping of 50mm thick and covering the chamber with 40X40X4 mm thick angle iron frame and 10mm thick RCC slab with type B0 1:2:4 concrete with 12.5mm graded aggregate as cover with handles made out of MS round bar 10 mm dia for lifting slabs including painting to the angle iron with two coats of synthetic enamel paint over a coat of redoxide primer and white wash for the man hole complete all as directed by Engineer-in-charge. 121 M&L for Providing precastreinforced cement concrete slabs 12.5 cm thick M-30 including reinforcementand 12 mm dia MS handle (with plain or interlocking joints as directed setting in mortar 1:6 of size of slab 1.20x1.20M. 122 LIGHTENING PROTECTION 123 M & L for single pointed Air termination Aluminium Rod 12 mm dia 500 mm long with Aluminium base plate of size 125 x 125 x 10mm fixed over hylam sheet of size 175 x 175 x 10mm and fixed on 1.5 Meter GI pipe 25mm Medium grade on roof all specified and as directed. 124 M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge.Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia medium grade GIwater pipe including GI protection pipe 40mm dia light grade for earth strip etc., 2. The cost of earth pit is deemed to be included in the unit rate. 125 AC & REF 126 Supply and install split AC units indoor/outdoorof capacity 2 TR, 3 star , Inverter type, single phase complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with copper condenser complete all as specified and directed 127 S& F Voltage Stabiliser 5 KVA, operating voltage range 130-290 Volt, Single phase complete all as specified and directed. 128 SCHEDULE A PART-IXPHASE -II Outsourcing for sub station for the First 11 Monthsduring Defect Liability Period . 129 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 130 One skilled operator in each shift 131 One semi skilled operator in each shift 132 SCHEDULE A PART-XPHASE -III Outsourcing for sub station for the Second 11 Monthsduring Defect Liability Period . 133 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 134 One skilled operator in each shift 135 One semi skilled operator in each shift 136 SCHEDULE A PART-XIPHASE -IV Outsourcing for sub station for the balance 02 Months after 22 months during Defect Liability Period . 137 Outsourcing for manning and operationof HT/LT Electrical sub station at 33/11 KV substation at NSB along with connected equipments installed round the clock (in 03 shifts) of each shift of 08 hours per day including Sunday and holidays complete all as specified and as directed. 138 One skilled operator in each shift 139 One semi skilled operator in each shift 140 Note for Item No. 127 to 138:-The rate shall include the following[i] For operation of all out door and indoor structures in the same area.[ii] Contractor shall laise with Dolphin hill sub station in case of major breakdown for early restoration of supply.[iii] In case any problem occurs which seems not under thecontrol of the operator, the same shall be immediately intimated to JE/ AGE E/M.[iv] Any additional man power required for early restoration of supply in case of emergency shall be provided by the contractor.[v] The contractor shall abide by the latest labour rules and minimum wages Act. Wages paid by the contractor to the emplopyed persons shall not be less than minimum wages fixed by the state/ central Govt from time to time whichever is higher.[vi] The contractor shall also insure the workmen employed on th job.[vii] The contractor is responsible for insurance, EPF, ESI, labour welfare cess etc., as applicable and shall be paid to the workmen as per existing Rules/ Acts/ regulations etc., and quoted is deemed to include the same. 141 SCHEDULE A PART-XIIPHASE -VOutsourcing for SCADA system for the First Year after Defect Liability Period . 142 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 143 SCHEDULE A PART-XIIIPHASE -VIOutsourcing for SCADA system for the Second Year after Defect Liability Period . 144 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 145 SCHEDULE A PART-XIVPHASE -VIIOutsourcing for SCADA system for the Third Year after Defect Liability Period . 146 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 147 SCHEDULE A PART-XVPHASE -VIIIOutsourcing for SCADA system for the Fourth Year after Defect Liability Period . 148 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 149 SCHEDULE A PART-XVIPHASE -IXOutsourcing for SCADA system for the Fifth year after Defect Liability Period . 150 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 151 SCHEDULE A PART-XVIIPHASE -XOutsourcing for SCADA system for the Sixth year after Defect Liability Period . 152 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 153 SCHEDULE A PART-XVIIIPHASE -XIOutsourcing for SCADA system for the Seventh year after Defect Liability Period . 154 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 155 SCHEDULE A PART-XIXPHASE -XIIOutsourcing for SCADA system for the Eighth year after Defect Liability Period . 156 Operation and comprehensive maintenace without manning of SCADA system including cost of spares post defect liability period operation including payment of bills by telecom service provider (Contractor to provide monthwise break down details of the same) complete all as specified and as directed. 157 Note for Item No. 140 to 155 [i] Cost of all minor spares/ components including OFC cables, Ethernet switches, connectors etc., is deemed to be included in quoted rate and any type of extra charge will not be made by Dept.[ii] All major defective spares shall be replaced by contractor on exchange basis which is deemed to be included in the unit price.[iii] All periodical tests of all safety devices in accordance with relavant safety standards with full oad testing will be borne by the contractor.[iv] Systematically examine & repair all the components such as software, monitors, servers etc., if any defect found,[v] All required special tools to be arranged by the contractor.[vi] Contractor shall be responsible for maintaining adequate lighting, cooling and moisture control, ventilation as required all at site complete.[vii] All safety measures/ directions and required tests for safety devices annually shall be borne by contractor.[viii] All periodical visits and all breakdown calls related to stoppage, malfunction, special services should be attended compulsory during all days including sundays & holidays.[ix] The contractor shall be liable to pay the telecom bill provided by the service provider.
Contract Date: Jan 06, 2026 Contract Value : 23.55 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
Andhra Pradesh View Result →
TenderDetail
Loading tenders