View Bid Results For Excitation System Tenders

We found 329 Bid Results related to excitation system tenders. You can find Contractor details who won excitation system tenders along with contract details in Bid awards announcements section.

Filters
Stage
266
45
18
Tender Publishing Platform
100
229
State / UT
29
32
31
30
27
25
25
21
20
18
17
10
9
9
6
6
6
6
5
5
3
3
3
3
2
2
2
1
1
1
Contract Value
75
60
136
57
Publish Date
0
1
0
0
0
Sector
20
160
43
28
22
11
10
8
8
8
6
5
4
3
3
2
2
2
2
1
1
Ownership
6
137
120
41
24
6
1
Within keyword
Active filters:
Showing 1–7 of 329 tenders matching your filters
1.
Agriculture #11475879 Technical Bid
Tender For Motor Rewinding Work- 1 Electric Motor Rewinding Insulation Class- B0.5 Hp, 720, 960, 1440, 2900 Rpm Stator 2 0.75 Hp, 720, 960, 1440, 2900 Rpm Stator 3 1.00 Hp 720, 960, 1440,2900 Rpm Stator 4 2.00 Hp 720, 960, 1440,2900 Rpm Stator 5 3.00 Hp 720, 960, 1440,2900 Rpm Stator 6 5.00 Hp 720, 960, 1440,2900 Rpm Stator 7 7.5 Hp 720, 960, 1440,2900 Rpm Stator 8 10 Hp 720, 960, 1440,2900 Rpm Stator 9 11.5 Hp 720, 960, 1440, 2900 Rpm Stator 10 12.5 Hp 720, 960, 1440, 2900 Rpm Stator 11 15.00 Hp 720, 960, 1440, 2900 Rpm Stator 12 20 Hp To 120 Hp, 720, 960, 1440, 2900 Rpm Stator 13 Rotor 14 Rewinding Of Crane Duty Motor 15 Hp, 960 Rpm, Insulation Class- H Rotor 15 Stator 16 25 Hp, 960 Rpm, Insulation Class- H Rotor 17 Stator 18 Slipring Motor75 Hp, 1440 Rpm, Squral Cage Rotor Of Alluminium Binding Converted Into Copper Strip Binding And Dynamic Balancing With Certificate. 19 120 Hp To 250 Hp, 960,1440 Rpm Strip Binding Rotor 20 Stator 21 250 Hp, 585 Rpm, Strip Binding Rotor 22 Stator 23 265 Hp, 960 Rpm, Strip Binding Rotor 24 Stator 25 400 Hp, 720 Rpm, Strip Binding Rotor 26 Stator 27 Rewinding Of Cane Unloader Motor S-5 Duty 415 Volt15 Hp, 965 Rpm , 900 Starts/Stop Per Hour Rotor 28 Stator 29 25 Hp, 965 Rpm , 900 Starts/Stop Per Hour Rotor 30 Stator 31 Three Speed Motor Insulation Class - Fcentrifugal Motor 110 Kw Ac 1St Speed Upto 200 Rpm 32 2Nd & 3Rd Speed Upto 450 Rpm & 960 Rpm 33 Dc-Motor D-412 Kcp Centrifugal Machine 167 Kv, 1250 Rpm Rotor 34 Stator 35 Repair Of Core Assembly For 3 Speed Motor Of Centrifugal Machine 36 Buffing & Policing Of Rotor Commutator Of Dc Motor For D-412 Centrifugal Machine 37 Welding Machine Spares Rewinding Primary Coil 38 Secondary Coil 39 Choke Coil 40 D.C.Welding Machine Rectifier 230/24 Volt, 600 Amp. 41 Rewinding And Repairing Of Electronic Welding Machine 3 Phase 400 Amp. 42 D.G.Set Spares Rewinding166 Kva Alternator Of Dg Set 1500 Rpm, 50Hz, Pole Of Rotor 4 Nos. Complete Rewinding H Class Enamelled Copper Strip With Material And Labour And Dynamic Balancing With Test Certificate Rotor 43 Stator 44 320 Kva Alternator Of Dg Set 1500 Rpm Rotor 45 Stator 46 166 Kva Alternator Set Excitation System (Booster) 47 320 Kva Alternator Excitor Rotor 48 320 Kva Alternator Excitor Filed Coil 49 Rewinding And Repair Of Submersible Pump Motor 15 Hp 50 25 Hp 51 Complete Rewinding Of 1875 Kva Excitor Rotor (Jyoti Make) Of 1500 Kw Alternator With Satisfactory Testing & Trial On Load. 52 Other Rewinding Workbreak Thruster Mootor 53 Cooler Fan Single Speed / Three Speed 54 Exhaust Fan Single Phase / Three Speed 55 Rewinding Of Celling Fan 56 Brass Holder For Turbine Excitor 57 Copper Carbon Brush For Turbine Excitor 58 Repairing Of D.C. Excitor (Jyoti Make) 15 Kw With Packing & Cutting Of Commutator & Re-Soldering Of Lug Etc. Complete 59 Charges For Supply Of Diode Fixing Plate Alluminium For 1875 Kva Turbine Alternator
Contract Date: Ref. Documents Contract Value : Ref. Document
Cooperative No of Bidders 3
Uttarakhand View Result →
2.
Educational and Research Institute #11433319 AOC
Procurement Of Tools & Equipment For Newly Established Iti For Girls At Ghatkesar In Medchal Malkajgiri District-25.00 Cost Supply And Delivery Of Cpu: 32 / 64 Bit, 7Th Generation Or Higher, I3 Or Latest Processor, Speed: 3 Ghz Or Higher. Ram: 8 Gb Or Higher, 1Tb Hdd / Sdd, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( As Available In The Market ) . Or All In One Pc Licensed Operating System And Antivirus Compatible With Trade Related Software. Make: Dell. Cost Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of 4Th Gen Ci5 Or Higher Processor, 4Gb Ram, 1Tb Hard Disk, Win8 / Latest Preloaded Licensed Os, 2Gb Graphics Card, Dvd Writer, Standard Ports And Connectors.Make: Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of To Enable Working With Wired Networks For Practical. Make:Finolex. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Broadband Connection With Min. 2 Mbps Speed / Optical Fiber. Make:Optic Fiber. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Registered Domain At Least 100 Mb Web Space. Make: D Link.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of All In One Printer A4 Size. Make: Hp Laser Jet.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dlp Projector With Screen / Multimedia Projector With Screen / Smart Interactive Board / Smart Tv Latest Version. Make:Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Online Ups 5Kva. Make: Utl. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply, Delivery, Installation And Testing Of Open Office Or Equivalent Latest Version. Open Source Software : Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of Python / Java Jdk. Latest Version. Open Source Software : Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of Gimp Or Equivalent. Latest Version. Open Source Software: Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of E Commerce Simulation Software.Latest Version. Open Source Software: Windows. 1.00 Cost Supply, Delivery, Installation And Testing Http Web Server / Xampp Or Any Other Similar Server.Open Source Software: Windows. 1.00 Cost Supply, Delivery, Installation And Testing Of My Sql. Latest Version. Open Source Software: Windows. 4.00 Cost Supply And Delivery Of Air Conditioner 2 Ton. Make: Blue Star.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost For Tools And Eqiupments Of Electronic Mechanic Trade: Cost Supply And Delivery Of Air Conditioner Two Ton Split Ac.Make:Blue Star. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Cro Dual Trace.20 Mhz ( Component Testing Facilities ) . Make: Htc / Varteck. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Battery Charger. 0 - 6 - 9 - 12 - 24 - 48 V, 30 Amp Make:Scientech. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Function Generator Dds Technology Sine Square Triangle Ramp Pulse Serial Data Ttl And Modulation. 1 Mhz -10 Mhz Function- Pulse – Modulation Generator With Built In 40Mhz Frequency Counter.Make:Pacific. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Digital Ic Tester. Dit-02 Make: Krb / Asi / Ssl Make. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Power Electronics Trainer With At Least 6 Numbers Of Application Board Mosfet Characteristics Scr Characteristicsscr Lamp Flasher Scr Alarm Circuit Series Inverter Single Phase Pwm Inverter.Electrical Type Make:Ohm. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 3.00 Cost Supply And Delivery Of Desktop Computers. Cpu: 64 Bit I7 8 Th Gen Processor, Speed: 3 Ghz Or Higher. Cache Memory: - Minimum 3 Mb Or Better. Ram:-8 Gb . Hard Disk Drive: 1 Tb 7200 Rpm ( Minimum ) Or Higher, Wi-Fi Enabled On Board Intigrated Wifi . Network Card:Integrated Gigabit Ethernet ( 10 / 100 / 1000 ) - Usb Mouse, Usb Keyboard And Monitor ( Min. 19.5 Inch ) , Standard Ports And Connectors. Dvd Writer, Speakers And Mic. Licensed Windows 10 Pro Operating System Antivirus / Total Security Preferably Hp / Dell / Lenova. Make:Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Laptop 8 Th Gen I7 Processor, 8Gb Ram, 1Tb Hard Disk, Windows 10 Pro Preloaded Licensed Os, 4Gb Graphics Card, Dvd Writer, Standard Ports And Connectors.Preferably Hp / Dell / Lenova Make:Hp / Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Laser Jet Printer A4 Size.Make:Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Internet Broad Band Connection 300Mbps.Make:Act / Bsnl / Jio. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Electronic Circuit Simulation Software With 6 User Licenses. Circuit Design And Simulation Software With Pcb Design With Gerber And G Code Generation, 3D View Of Pcb, Breadboard View, Fault Creation And Simulation..Make:Edwin. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dso Colour. 4 Channel , 50Mhz Real Time Sampling 1G Samples / Sec, 12 Mpts Memory With Pc Interface Usb, Lan And Math Function Includes +, -, Fft, Differential, Integral, Abs, Log Etc.Make:Aet. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Soldering & De Soldering Station.200 Watt Adjustable.Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Frequency Modulator And Demodulator Trainer Kit.Fm Modulator Type : Reactance Modulator, Varactor Modulator, Vco Based Modulator Fm Demodulator Type All 5 Demodulation Techniques Detailed Teaching And Learning Contents Through Software.Make:Ohm. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Pam Ppm Pwm Trainer Kit Pam - Ppm - Pwm Trainer Kit Is A Uses Natural And Flat Top Sampling Techniques For Modulation And Demodulation Process. Features: Pam-Ppm-Pwm M. Make:Ohm. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Am Fm Commercial Radio Receivers Tr105 Portable Radio Support Fm / Am / Sw / Cb / Vhf / Air Radio Make: Krb Make. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Application Kits For Microcontrollers 6 Different Applications One Set 1.Input Interface : 4X4 Matrix Keypad, Ascii Key Pad, Four Input Switch 2. Display Module 16X2 Lcd, Seven Segment, Led Bar Graph 3. Adc / Dac Module With Most Popular Dc / Dac0808 4. Pc Interface: Rs232 & Usb 5. Motor Drive: Dc, Servo, Stepper 6. Daq: Data Acquisition To Sense Different Sensors Signals. Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Sensor Trainer Kit Containing Following Sensors 1 Thermocouple 2 Rtd 3 Load Cell Strain Gauge 4 Lvdt 5 Smoke Detector Sensors 6 Speed Sensor 7 Limit Switch 8 Photo Sensors 9 Optocouplor 10 Proximity Sensor.Graphical Touch Lcd With Inbuilt Processor For Viewing The Output Waveforms, In Built Daq, And Standard Processing Circuits Like Inverting , Non – Inverting , Power, Current , Instrumentation Differential Amplifier, F / V, V / F, V / I, I / V Converter, Sensors :Rtd, Ntc Thermistor, Lm35 Thermocouple, Gas ( Smoke ) Sensor, Load Cell, Lvdt Sensor, Speed Sensor. Make:Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Different Types Of Electronic & Electrical Cables Connectors Sockets And Terminations 1Mm Sqmm Ti 4Mm Sqmm, 3Pin Socket, 5Pin Socket, Terminal Complet Set. Make:Phenolex. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Fiber Optic Communication Trainer Full Duplex Analog & Digital Trans-Receiver With 660Nm & 950Nm, Noise Generator With Variable Gain, Four Seven Segment Display Ber Counter, Eye Pattern Make:Pacific. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Mobile Phone Trainer. 2G / 3G / 4G Dual Sim Gsm Handset.Frequency Measurement And Band Verification. Real Time Mobile Operation Make:Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Smart Phones Of Different Make ( Android / Windows ) Android / Windows Make:Nokia / Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Lcd Tv ( Trainer Kit ) 21-Inch Full Hd Lcd Color Television Should Support Pal / Ntsc Video Formats Complete Block Diagram Of A Lcd Tv System, Study Board Indicating Various Sections Of Lcd Tv Along With The Test Points And Switch Faults. Make:Sony. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Lcd Tv ( 21 ) Full Hd Telivision. Make:Samsung / Sony. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Led Tv ( Trainer Kit ) 20-Inch Full Hd Led Color Television, Pal / Ntsc Video Formats, Complete Block Diagram Of A Led Tv System, Study Board Indicating Various Sections Of Led Tv Along With The Test Points And Switch Faults Trouble Shooting In Different Sections. Make:Sony. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Solar Training Kit / Simulator With Build In Meters For Dcv Dca Ac Multifunction Meter Frequency Protection Circuits Bs-10 Terminals For Making The Connection Single / Dual Axis Traking System Charge Controller Pwm Based Mppt Charging Stage Bulk Absorptions And Float Make:Trina / Vikram. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Led Lighting System Measurement Of Power, Voltage, Current, Power Factor And Light Output Performance Of Different Lighting Products Like Led, Cfl At Variable Input Voltages 0 To 245V Variable Ac Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Tools And Equipments Of Computer Aided Embroidery And Designing Nsqf: Cost Supply And Delivery Of Over Lock Machine.3 Thread. Make:Juki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Single Head Computerized Embroidery Machine ( Multi Needle ) With Ups Pr1055x. Make:Brother Pr1055x Entrepreneur Pro X Single Head 10 Needle Computer Embroidery Machine. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply, Delivery, Installation And Testing Of Coral Draw Software. 4.00 Cost Supply And Delivery Of Desktop Computer With Ups. Cpu: 32 / 64 Bit I3 / I5 / I7 Or Latestprocessor, Speed: 3 Ghz Or Higher. Ram:-4 Gb Ddr-Iii Or Higher, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( Min. 17 Inch Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Hp / Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Laptop 12Th Generation Inte Core I5 Prosses0r O S Windos 11 Ho 1920*1080 Intel Me 16 Gb Ram, 512 Gb Ssd Hard Drive 35.6 Cm 14 Diognal Fhd. Make:Hp / Dell With Ms Office And Inbuild Windows. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Multi-Functional A3 Size Colour Printer Latest With Trolley. Make: Canon. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Printer Laser Jet Pro M 202Dw. Make: Canon. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Scanner Hp / Dell. Make: Canon. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Automatic Sewing Machine ( With Necessary Attachments ( Zip Fixing, Plcot Gathering Foot Etc. ) ( With Necessary Attachments ( Zip Fixing, Plcot Gathering Foot Etc. ) Make: Zuki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 3.00 Cost Supply And Delivery Of Air Conditioner Of 2 Ton Capacity With Stabilizer. Make:Blue Star.Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Computer Set With Ups &Multimedia Projector. Cpu: 32 / 64 Bit I3 / I5 / I7 Or Latestprocessor, Speed: 3 Ghz Or Higher. Ram:-4 Gb Ddr-Iii Or Higher, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( Min. 17 Inch Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Dell / Hp / Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Ac Unit Split Type. 2 Ton Capacity With Stabilizer. Make:Blue Star. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Ac Unit Split Type. 2 Ton Capacity With Stabilizer. Make:Blue Star. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost For Tools And Eqiupments Of Fashioon Design & Technology: Cost Supply And Delivery Of Dress Forms ( Dummies ) Children Ladies Gents ( Fibre ) . Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Computer Set With Ups & Multimedia Projector. Cpu: 32 / 64 Bit, 7Th Generation Or Higher, I3 Or Latest Processor, Speed: 3 Ghz Or Higher. Ram: 8 Gb Or Higher, 1Tb Hdd / Sdd, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( As Available In The Market ) . Or All In One Pc Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Dell / Hp / Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of White Magnetic Board With Felt Board & Accessories Of Size:17X23 ( Fibre With Wooden Frame ) . Make:Roger And Moris. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 25.00 Cost Supply And Delivery Of Sewing Machine - Single Needle Lock Stitch Industrial Model 3 Thread ( Electric Type ) . Make: Juki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Over Lock Machine 3 Thread ( Electrict Type ) . Make:Juki. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 24.00 Cost Supply And Delivery Of It Lab With Computers Setup &Installation Along With Ups Required Configuration For Software ( Corel Draw ) Cpu: 32 / 64 Bit, 7Th Generation Or Higher, I3 Or Latest Processor, Speed: 3 Ghz Or Higher. Ram: 8 Gb Or Higher, 1Tb Hdd / Sdd, Wi-Fi Enabled. Network Card: Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor ( As Available In The Market ) . Or All In One Pc Licensed Operating System And Antivirus Compatible With Trade Related Software. Make:Dell / Hp. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply, Delivery, Installation And Testing Of Designing Software Coral Draw. Latest Version Make:Coral. 1.00 Cost Supply And Delivery Of Multi Functional A4 Colour Printer. Printer With Trolly / Table. Make:Hp Laser Jet. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Lcd Projector. Make:Epson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Vacuum Cleaner.Lab Cleaning ( Latest ) . Make:Euroclean Wd X2 Dry And Wet Vacuum Cleaner. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 List Of Tools And Equipment Of Electrician Trade: Cost Supply And Delivery Of Drill Hand Brace 0-100Mm ( Stainles Steel ) Make:Hudson. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Load Bank ( Lamp / Heater Type ) .6 Kw, 3Ph Make:Kohir / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Electronic Components. Consisting Resistors, Diode, Transistor, Ujt, Fet, Scr, Diac, Traic, Igbt, Small. Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 3.00 Cost Supply And Delivery Of Bus Bar With Brackets.1 Mtr Each. Make:Siemens / L &T / Ge. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Rcc Pole With Accessories ( Ms Angle Iron, ‘C’ Clamp, Stay Insulator Etc. ) And Materials.6 Mtr Make:Superior. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Tachometer. Analog Type - 10000 Rpm Make: Metrix / Meco / System. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of G. Auto Transformer Type. Make:Krb / Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Oscilloscope Dual Trace 20 Mhz Make:V A R Tech Ss 5020 B Oscilloscope 20 Mhz Dual Channel Cro. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Oil Testing Kit 230 V, Single Phase 50 Hz 60 Va Output 0-60 Kv Variable. Make:Kiloskar / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Inverter With Battery 1 Kva With 12 V Battery, Input- 12 Volt Dc, Output- 220 Volt Ac Make:Luminous . Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Battery Charger 0 - 6 - 9 - 12 - 24 - 48 V, 30Amp. Make:Elektron . Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Solar Panel With Battery 18 Watt. Make:V-Guard / Exide. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of I5 And I7 Generation Computer Or Latest Version & Instalation 2.8 Ghz & Above, 8 Gb Ram, 500 Gb Hdd, Dvd Combo Drive, 19 / 21” Monitor, Optical Scroll Mouse, Multimedia Keyboard, 32 Bit Lan Card With Upp Port, Necessary Drivers, Etc. Or ( Latest Version ) . Make:Hp / Dell. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ink Jet / Laser Printer. Laser Jet Pro M 202 Dw. Make:Hp / Samsung. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of D.C. Shunt Generator With Control Panel, ( With Installation ) .2.5 Kw, 220V &3Phase Squirrel Cage Induction Motor, 5Hp, 440V With Control Panel & Star Delta Starter. Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Motor-Generator ( Ac To Dc ) ( With Installation ) .Squirrel Cage Induction Motor With Star Delta Starter And Directly Coupled To Dc Shunt Generator And Switch Board Mounted With Regulator, Air Breaker, Ammeter, Voltmeter, Knife Blade Switches And Fuses, Set Complete With Case Iron And Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Induction Motor Rating: 7.5 Hp, 415V, 50 Cycles, 3 Phases. Dc Shunt Generator Rating: 5 Kw, 440V ( Output Voltage Varies 110-440V ) Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of D.C. Compound Generator With Control Panel Including Fitted Rheostat, Voltmeter, Ammeter And Breaker, 2.5 Kw, 220V &3Phase Squirrel Cage Induction Motor, 5Hp, 440V, With Control Panel & Star Delta Starterr. Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dc Series Motor Coupled With Spring Balance Load With Instalation. 2.5 Kw, 220 Volts Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dc Shunt Motor 2.5 Kw, 220 V. Make:Crompton / Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Dc Compound Motor With Starter And Switch ( With Installation ) .2.5 Kw , 220 Volts Make:Kbr / Crompton / Kiloskar. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Motor Generator ( Dc To Ac ) Set Consisting Of - Shunt Motor With Starting Compensator And Switch Directly Coupled To Ac Generator With Exciter And Switch Board Mounted With Regulator, Breaker, Ammeter, Voltmeter Frequency Meter, Knife Blade Switch And Fuses Etc. Set Complete With Cast Iron Bed Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. ( With Installation ) . Shunt Motor Rating: 5 Hp, 440V Ac Generator Rating : 3-Phase, 4 Wire, 3.5 Kva, 400 / 230 Volts, 0.8 Pf, 50Cycles Make:Kbr / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ac Squirrel Cage Motor With Star Delta Starter And Triple Pole Iron Clad Switch Fuse With Mechanical Load. ( With Installation ) 5 Hp, 3-Phase, 415 V, 50 Hz Make:Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ac Phase-Wound Slip Ring Motor With Starter Switch. 5 Hp, 440 V, 3 Phase, 50 Hz Make:Krb / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Universal Motor With Starter / Switch. 240 V, 50 Hz, 1 Hp Make:Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Synchronous Motor With Accessories Like Starter, Excitation Arrangements.3 Phase, 3 Hp, 440V, 50Hz, 4 Pole Make:Krb. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Thyristor / Igbt Controlled D.C. Motor Drive With Tacho-Generator Feedback Arrangement ( With Installation ) 1 Hp. Make:Kbr / Havells / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Thyristor / Igbt Controlled A.C. Motor Drive With ( With Installation ) .Vvvf Control 3 Phase, 2 Hp Make:Kbr / Havells / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 2.00 Cost Supply And Delivery Of Three Phase Transformer, Shell Type Oil Cooled With Delta / Star. 3 Kva , 415 / 240 V, 50 Hz Make:Kbr / Havells / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Electrical Machine Trainer – Suitable For Demonstrating The Construction And Functioning Of Different Types Of Dc Machines And Ac Machines ( Single Phase And Three Phase ) . Should Be Fitted With Friction Brake Arrangement, Dynamo Meter, Instrument Panel And Power Supply Unit. Make:Kirlosker / Siemens / Havells / Benn / Energy Pack / Crompton. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Diesel Generator Set With Changeover Switch, Over Current Breaker And Water / Air-Cooled With Armature, Star-Delta Connections Ac3 Phase, 7.5 Kva, 415 Volt Or Higher Rating Make:Bharath / Mahahendra. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Used Dc Generators-Series, Type For Overhauling Practice 5Kva. Make:Krb / Kirlosker. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Used Dc Generators- Shunt Type For Overhauling Practice 5Kva. Make:Krb / Kirlosker. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Used Dc Generators-Compound Type For Overhauling Practice 5Kva. Make:Krb / Kirlosker. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Pillar Electric Drill Machine Motorized. 12-20 Mm Capacity, 1Hp, 440V, 3 Phase, Induction Motor With Dol Starter, Bench Type. Make:Vimal / Glow. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Motorised Bench Grinder. 1 Hp. 3 Phase, 440V With Dol Starter, Double Side With Smooth And Rough Wheel With Tool Base Make:Bosch / Metro. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ceiling Fan Coil Winding Machine. 250V, 50 Hz, 1-Ф, With Speed Control. Make:Shyam. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Primary Current Injection Set.220V, 50 Hz, 1-Ф, Output Current - 200 A ( Min ) With Timer Make:Krb / Atico. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ev Charger 3 Phase Input. Make:Tata Power Ez. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 1.00 Cost Supply And Delivery Of Ev Charger ( Home ) 1 Phase Input. Make:Tata Power Ez. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete. 4.00 Cost Supply And Delivery Of Working Bench. 2.5 M X 1.20 M X 0.75 M ( Iron ) Make:Standard. Including Packing Loading Unloading And Transportation To Site Commissioning And Testing Etc., Complete.
Contract Date: Ref. Documents Contract Value : 1.12 Crore
Government Departments No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
Chhattisgarh View Result →
5.
Housing Urban and Rular Development #11319892 AOC
Quotation for NON CSR Electrical Item for the work supply installation testing and commissioning of Electrification at the Mahalaxmi Temple, Kolhapur,Dist.Kolhapur- 1 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (4 m poles) 2 Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for DG Set). 3 SITC of ESE type Lightning Arrestor Air Terminal as per standard NFC 17-102, Level IV with protection radius 51 mtr @ mounting height 5 meter.LA should be have CPRI test cerficate and should have test cerficate as per NFC 17-102 of suitable europian authority. 4 SITC of 3 meter height Mounting structure MAST (FRP/G.I.), along with supporting guy rope, base plate, mounting structure, required nut bolts etc. 5 SITC of Strike Recorder with weather proof Enclousure. It should be standalone type with no external power source requirement. 6 SITC of Test Link 7 SITC of Pipe in Pipe type GI maintanance free earthing - 80/38 (3.0 Mtr.s) with all other loose acessories and earthing pit chamber and cover. 8 SITC of single core 35 Sq. MM. Insulated Alm. Armoured Cable along with all installation accessories like clamp etc. (Optional) from LA to Earth Pit. Manufacturer to specify Copper/Aluminium). 9 Supplying, fixing and commissioning of MLTP including: Incoming - 200A MCCB 25 KA-2 nos, 200A ATS 4P - 1 Nos, Bus 250A Aluminium Outgoing : 63A 4P MCB - 5 Nos, 40A 4P MCB- 10 Nos, 125A 4P MCCB - 1 Nos, 160A SP MCCB - 1 Nos with floor mount stand 10 Supplying, fixing and commissioning of LTFP with 200 AMPS MCCB Incomer 8 Nos. Outgoing with 40 AMPS FPMCB 11 Providing & erecting 4 Pole MCCB, 415 V, 125A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 12 Providing & erecting 4 Pole MCCB, 415 V, 160A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 13 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 200 mm width & 50 mm height complete with necessary coupler plates & hardware. 14 Providing & erecting hot dipped galvanised Raceway with cover manufactured from 16 SWG (1.6 mm thick) GI sheet of 100 mm width & 50 mm height complete with necessary coupler plates & hardware. 15 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 200 mm x 200 mm complete with necessary cover plates & hardware. 16 Providing & erecting hot dipped galvanised junction box manufactured from 18 SWG (1.2 mm thick) GI sheet of 300 mm x 300 mm complete with necessary cover plates & hardware. 17 Supply and Installation of 5MP PoE IP Bullet Camera with automatic varifocal lens from 3.3 to 10 mm lens and 30 meter inbuilt IR, Dual Streams with configurable bit rate, GOP and frame rate, Edge based Video Analytics- object classification (Human/Vehicle), object in field, line crossing, enter field, leave field, loitering, follow route, objects stopping or starting to move, counting, occupancy, condition change, similarity search, 16 number of analytics/rules can be configured simulaneously. The video analytics software can detect up to 64 objects per frame in real time. support memory card up to 2TB capacity with health monitoring for early service indication. The recording in local storage should also be AES encrypted, support ONVIF S,G,T,M with MQTT event forwarding, onboard data security by using TPM (Trusted Platform Module) and PKI, supports TLS 1.3, Secure boot, Signed Firmware, software sealing to notify of device configuration changes, Embedded Login Firewall to minimize DDOS Attack, X.509 v3 digital certificates with SHA516 signature hash, audit logs, Unsecure ports like HTTP and RTSP are disabled by default, uses RTSPS/SRTP for video streaming, UL 2900-2-3 Level 2 cybersecurity certified, Camera should have UL, EN, CE, FCC, NDAA, with IP 66 and IK10 impact protection 18 Supply and Installation of 5MP Outdoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE)Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, IP66 and NEMA 4X, IK10, CE, FCC , UL certified. SD card support up to 2TB. 19 Supply and Installation of 5MP Indoor Dome camera with 1/2.9‑inch CMOS, Effective pixels 3072 (H) x 1944 (V), 30fps, Sensitivity – (3100K, reflectivity 89%, 1/25, F1.3, 30IRE) Color 0.24 lx Mono 0.03 lx With IR 0.0 lx, 120 dB Dynamic range, Electronic Day/Night, Automatic Electronic Shutter (AES), H.265, H.264 MP (Main Profile); M-JPEG Video compression, White balance, Backlight Compensation, Privacy Mask,Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Audio detection (if microphone used), 3 to 10 mm Automatic Varifocal (AVF) lens, MicroSD card slot for edge recording, Motion, tamper and audio detection(if microphone used), FTP, IR range upto 30mtrs Dropbox and e-mail applications, 3 axis adjustment, ONVIF Profile S & G & T, PoE, CE, FCC , UL certified. SD card support up to 2TB. 20 Supply and Installation of 12MP IR Panoramic camera with 1/2.3‑inch CMOS, 360° lens, Effective Pixels 3008 x 3008 (9 MP), 1 to 25 [30] fps, Sensitivity @30IRE: 0.15lux(color), 0.048lux(mono); 0 lux with IR; 20m IR; 120 dB WDR, Video compression H.264 (MP)/ H.265 (MP); M- JPEG, Electronic Day/Night, White Balance, Automatic Electronic Shutter, Backlight compensation, Intelligent Dynamic Noise Reduction (iDNR), Privacy Masking, Rule based alarms and tracking, Line crossing, Enter /leave field, Follow route, Loitering, Idle / removed object, People counting, Crowd density estimation, 3D tracking based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), Camera Trainer (machine learning to train user specified objects), Built-in microphone(Integrated array with 3 digital MEMS audio sensors), Signal-to-Noise Ratio, Full-duplex / half duplex Audio Streaming, Memory card slot, 10/100 Base-T, ONVIF Profile S,G, M & T, clientside/cameraedge dewarping,IP66, NEMA 4X, IK10, PoE, CE,UL, FCC. 21 Supply and Installation of all-in-one recording, viewing and management solution for network surveillance systems for up to 256 channels, Pre-installed, pre-configured IP storage solution, with RAID-5/RAID-6 protected, Dedicated storage operating system delivers robust , secure operation, Hot-swappable hard drives, Advanced user and alarm management,Intel® Core™ i7-12700E (25 MB Intel® Smart Cache 2.10 GHz) Processor,16 GB DDR5,ECC UDIMM memory installed, 2U rack mount, 12 Trays: 3.5- inch SATA 3; max 18TB per HDD slot maximum supported, 12Gb/s SAS RAID Card, 4 USB ports; Intel onboard graphics (Intel® UHD Graphics 770),Microsoft Windows Server IoT 2022 for storage standard,UL, CE Certified. 2 x RJ45 Gigabit Ethernet LAN ports (teamed); 1 IPMI BMC port. Operating temperature (°C) 0°-40°C; Operating relative humidity, noncondensing (%) 8 - 90%. Video Managment software In-built (Server-client architecture) with Live viewing of multiple cameras, Local recording and snapshots, PTZ control and digital zoom, Playback and export from storage, Motion and forensic search, Multi-screen grid selection , Sequencing selection, favorite view design.Dual authorization login,e Map support,ONVIF profile S,T complied,User management,Alarm management,SQL based database,LDAP support.Support of camera edge based analytics/server based analytics alarm triggering. Certifications UL,CB,CE,FCC,NDAA,BIS 22 Supplying & erecting 55 professional LED display with 1920 *1080 ( Full HD) Display, suitable for 32/64 channel NVR and following features Brightness: minimum 500 Cd/m2 Contrast Ratio: minimum 1000:1 Viewing angle: 178/178 deg. Response time: maximum 8 ms Inputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON 23 Supply and Installation of Client Workstation with 21 Inch Monitor 24 RE-2AS Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex Supply of EN 54-16 certified and EN 60849 standards, public address and voice alarm system that ensures a fast, safe and controlled emergency evacuation. It should have 2 class D 500W amplifiers, one shall be for the feild output with two configurations for 100V/70V lines and another one is as standby backup, 6 zones, 3 audio inputs, 6x6 audio matrix,Digital Signal Processing Based Voice Alarm Controller and LCD display 2 rows x 16 characters with 3 inputs. It should have the provition for battery installation with proper rigit & safe mounting option. It shall be suitable for both Wall or Rack mounting provision and have following features:- 1. Support Up to 8 MPS-8Z multizone micropohones or VAP-1 panels connected with CAT5 UTP cable 2. Digital Amplifier (inbuilt) 2X500 watts and 6 zones,Backup amplifier included . 3. 4 pre-amp outputs for external PAamplifiers connection. 4. 10 minutes storage for pre-recorded messag. 5. USB connectivity. 6. Password protection, 7. Overriding Facility for Emergency Condition. 8. Have In-Built or attached MIC. 9. Work on 100 - 240V~ 50/60Hz and standby battery 1x 12VDC. 10.FireAlarm Control Panel integration. 11. Interface MODBUS RTU RS 485 Half duplex 25 RE-2AS BC Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x H x D) : 190 x 20 x 140 mm . Supply of the Battery update and activation card EN54-4 certified for RE-2AS. Once activated, the card becomes a key for the charger to work permanently.Package dimensions (W x Hx D) : 190 x 20 x 140 mm 26 RE-2AS PTT Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. Supply RE-2AS PTT dynamic microphone adds more versatility to your RE-2AS unit. This new device allows you to have a public announcement input right there at your fingertips. This Push To Talk microphone can be directly connected to the priority audio input to bypass the background music. As it is directly powered from the USB port inside the unit, you do not need to add an external power supply. 27 RE-2AS MPE Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. Expansion unit model RE-2AS MPE for the paging microphone RE-2AS MP8Z. It has 8 software programmable buttons for paging up to 8 public address zones. It has an iron chassis to provide stability and protection against damages. All buttons are designed for an intensive use. 28 RE-2AS WMK Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet Supply of the Wall mounting kit allows to install a PAVA unit on wall. It should be made of 1.5 mm galvanized sheet 29 RE-2AS 4L Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. Supply, installation, Testing, & commissioning of Network module to connect multiple PAVA systems., cable length Up to 200m per node and up to 4 units and 24 zones, 4 PAVA systems shall be network with length of max 800m,dimmensions (H x W x D)120 x 100 x 80 mm. 30 Supply, fabrication & Installation of thermal insulation on GI ducts complete with Closed Cell foam anti microbial insulation (Nitrile Rubber) with minimum density of 40 Kg/m3 with minimum R Value 4.1/inch & thermal conductivity -0.035 w/mok confirming to Class O & the inner side stuck to the outer facia of the GI ducts with recommended / Proprietory adhesive bonding inline with LEED requirements & installed as per manufacturers recommendation. The insulation joints shall be sealed with 3 wide Black Tape. Thermal Insulation - 9mm thick 31 Supply, fabrication and installation of acoustic lining of supply and return air ducts as specified and shown on the drawing complete with 10 mm thick acoustic insulation with Open Cell Foam Insulation - ArmasoundMicroban antimicrobial product protection withThermal conductivity 0.045 W/m deg.K / density 140~180 kg/m3, with manufacturer recommended adhesive inline with LEED requirement.Acoustic Insulation - 13mm thick 32 Electrical panel with outgoing for 2nos. Of VRV ODU and IDU 33 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 34 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 36W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 9300 Candella . Bodymade of Die cast Aluminium.Effective delivered lumens 3000-3200, ,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 35 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 36 Supplying, fixing and commissioning of Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT,Body Made of Die Cast Aluminium30 deg Medium beam . Effective delivered lumens 1350-1400, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 37 Supplying, fixing and commissioning of Under Water Step Light IP 68 with RALfinish LED 5-8W, 3000K CCT, Medium beam.Effective delivered lumens 400- 600,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 38 Supplying, fixing and commissioning of Surface Mounted downlight IP 65 with RAL finish LED 20W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 39 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 24W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 6180 candella . Bodymade of Die cast Aluminium.Effective delivered lumens 2000-2200,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 40 Supplying, fixing and commissioning of Customized Deep mala Light IP65 with RAL finish LED 2-3W, 2400-2700K CCT, Diffused Beam° , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 80 including DALI driver.. Standard Warranty 5 Years. 41 Supplying, fixing and commissioning of Adjustable Surface Mounted Spotlight IP 65 with RAL finish LED 15W, 3000K CCT, Medium 30 deg beam Having Minimum CBCP value of 3000 candella . Bodymade of Die castAluminium. Effective delivered lumens 1200-1400,MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 42 Supplying, fixing and commissioning of Ground recessed Uplight for column, IP 67 RatedBody to be of High Grade Die Cast Aluminium with SS trim. Fixture to have 10w Led with Cool Touch Feature, Narrow 10 deg beam ,Color tempreture to be 3000k ,800-850 lumens, 90 Cri 3 Step Mac Adam with Remore Dali Driver, glare rating UGR<16. Lifespan ≥ 50000 hrs, Ambient temperature 25°-40° C, L&B Ratio L70/B20 with Lumen Maintenance LM80, Standard Warranty 5 Years. Additional mounting accessories : Honeycomb louvre 43 Supplying, fixing and commissioning of Surface Mounted Adjustable Spotlight , Auminium Die Cast Body, IP 65 Ratedwith RAL finish LED 15W, 3000K CCT, Medium beam . Effective delivered lumens 1200-1300, MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Standard Warranty 5 Years. 44 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 3W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 40-50 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 45 Supplying, fixing and commissioning of Adjustable Mini Surface Mounted Spotlight IP65 Body to be made of Die Cast Aluminium with RAL finish LED 5W, 3000K CCT, Narrow 15 degbeam . Effective delivered lumens 150-200 , MacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, , L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90 including DALI driver. Additional mounting accessories : Honeycomb louvre. Standard Warranty 5 Years. 46 Supplying, fixing and commissioning of Recessed Linear Grazer Die Cast Aluminium Body with SS Trim,LEDwattage to be 10-14W/m RGBW CCT Grazer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens: 500-600Real lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 47 Supplying, fixing and commissioning of Surface MountedLinear Grazer IP 67 ratedDie Cast Aluminium Body with adjustable Brackets, LED wattage to be 15W/m 3000K CCT Garzer 10x24 deg Optic,Remote Dali Dimmable, Delivered lumens:Real 1200lm/m,glare rating UGR<19L&B Ratio L70/B10 with Lumen Maintenance LM80, CRI 90.. Standard Warranty 5 Years. 48 Supply, Installation, Testing and Commissioning ofAdjustable Gobo Projector Light , Body to be Made of Die cast Aluminium, Wattage of 180w Beam, 5200 lumens, 4 Gobo Modules , IK 08 CCT 7000k , Degree 15-45 deg Motorized Zoom, IP 66 rated. CRI >70. Driver Inbuilt DMX RDM Controlled. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer. 49 Supplying, fixing and commissioning of Post Top LuminaireIP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 50 Supply, Installation, Testing and Commissioning ofPole Mounted Adjustable Gobo Projector Light having Wattage of 40W and Delivered Lumens of 2500. Beam Degree 17-30., IP 65 rated with Pole mounting Bracket. CRI >70. Driver to be non dimmable and Integrated. Life time of Led L70B20 @ 35000 hrs. Gobo design to be decide by Architect/Lighting Designer.Including 4mtr. pole (procurred locally) 51 Supply, fabrication, and installation of a custom-made heritage chandelier of diameter 2000 mm and height 2000 mm, made from heavy-duty metal frame with antique brass / bronze / gold leaf finish as approved by the architect. The chandelier shall include precision-cut K9 / lead crystal elements in pendants, prisms, and beads, arranged in multi-layer form to create a grand decorative effect. Fixture shall be suitable for E14 / E27 LED lamps or integrated LED modules, providing warm white light (2700K–3000K) with CRI ≥ 90 and dimmable control.Suspension shall be with heavy-duty chain/rod system and canopy plate designed to safely carry the total load with 3× safety factor. All wiring shall be flame-retardant copper with proper earthing. The chandelier shall comply with IEC / IS standards and be supplied with shop drawings, finish samples, and load details for approval. Minimum warranty: 5 years. 52 Supply, Installation, Testing and Commissioning of Decorative Wall Light. Housing: IP65 & IK10 with RAL finish, LED 40W, 2200K CCT, Symmetrical beam optics. Effective delivered lumens 2000-2200 lumensMacAdam Step 3, glare rating UGR<19, Lifespan ≥ 50000 hrs, Ambient temperature < 40° C, L&B Ratio L80/B20 with Lumen Maintenance LM80, CRI 80+. Standard Warranty 5 Years 53 Supply, Installation, Testing & Commissioning of International seeTouch QS Wallstation Insert 5 Button with Raise/Lower QSWE-5BRL 54 Supply, Installation, Testing & Commissioning of DALI Dimming controller; Controls 2 independent DALI links with up to 64 DALI ballasts per link. Can take care of Color Tunable fixtures. 4 groups of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSN-2UNVDAL- D 55 Supply, Installation, Testing & Commissioning of Switching module with 4channels, each channel with minium 5 amp rating with provisions of sensors inputs: Occ sensor, daylight sensor and IR sensor. Requires mains/line voltage feed Similar to Lutron QSNE-4S 5230D module 56 The QSE-CI-DMX control interface allows zones on a to control DMX512-controlled devices Any zone can be mapped to either a single DMX512 channel or to three separate DMX512 channels, for RGB/CMY color-control The DMX channels (maximum of 32) are mapped to zones, and can be programmed as 1- channel lighting, 1-channel integration, or 3-channel RGB/CMY 57 Supply, Installation, Testing & Commissioning of central processor assembled processor with one/two configurable links and inbuilt BACnet for occupancy status. Each processor link can be configured to be a dimmer link, shade link, or dimmer power panel link. Processor accpets 220-240V, 1 phase, 2 wire, 10A feed, (throiugh power supply) Similar to Lutron Athena 58 Supply, Installation, Testing & Commissioning of Power Supply Unit for supply PDUs to Antenna devices Similar to Lutron QSPS-DH -1 -75Approved Makes :Lutron, Crestron, Pharos,Enlighten 59 Supply, Installation, Testing & Commissioning of Lighting control and monitor software, captures floor wise consumption, each event, Energy Reporting & monitoring per processor, 60 Supply, Installation, Testing & Commissioning of Lighting control BACnet softwares for BMS integration. This license for BACnet software enables a third-party building management system to control, monitor,and manage lights and shades in various areas on a processor. This license can also be used to share information between the control system and other control systems such as area occupancy, power usage, lighting state, etc. License required 1 per processor. 61 Supply of QS cable for power and data simialr to Lutron QS-CBL-LSZH Cable Adheres to CE standards for Low Smoke Generation (EN 60332-1-2), Halogen Gas Emission (EN 61034-2), and Flame Retardation (EN 60754- 1&2). • Five Conductors: Common – 0.75 mm2 (18 AWG) Power – 0.75 mm2 (18 AWG) MUX Data – 0.25 mm2 (22 AWG) _ Data – 0.25 mm2 (22 AWG) Drain Wire – 0.2 mm2 (24 AWG) Laying in suitable conduits to be done by Electrical contractor. 62 The scope of work includes the supply, installation, testing, and commissioning of asuitable Distribution Board (DB) box for mounting dimming and switching modules,complete with all necessary accessories such as enclosures, busbars, terminalblocks, MCBs, internal wiring, and supports, as per approved drawings andspecifications; the DB box shall be of robust construction, properly ventilated, factoryfinished, and designed to facilitate easy integration with the Lighting ManagementSystem, ensuring safe, reliable, and efficient operation after successful testing andcommissioning. 63 Programming of complete systemThe scope of work includes the complete programming, testing, and commissioningof the Lighting Management System (LMS), covering configuration of lighting zones,dimming levels, sensors, and schedules as per the approved control philosophy,integration with BMS/third-party systems if required, point-to-point and functionaltesting of all devices, fine-tuning and calibration, preparation of test reports and asbuilt documentation, and providing necessary training to client/end-user staff toensure the LMS is fully functional, compliant, and ready for handover. 64 Supplying, erecting, testing and commissioning of diesel generating set with alternator of 160 kVA confirming to CPCB IV Plus emmision compliant with output continuous rating. 3 Phase. 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed (liquid cooled multi-in line cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/-5%, with performance class G2. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears,indicators connected with suitable zires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m. with suitable capacity DEF tank provided with first Filling of oil, diesel tank capacity not less than 385 Ltr etc. on provided M20 Grade CC Foundation and obtaning necessary aproval from electrical inspector if necessary. This DG Set is fiited in sound prof and whether proof Acoustic Enclosure asper CPCB IV plus emisison complaint as per specification no. GEN-DG
Contract Date: Jun 19, 2026 Contract Value : 1.28 Crore
Government Departments No of Bidders 3
Maharashtra View Result →
6.
Housing Urban and Rular Development #11300693 AOC
Tender for Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means Over Areas (Exceeding 30 Cm In Depth, 1.5 M In Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Lead Upto 50 M And Lift Upto 1.5M Disposed Earth To Be Leveled And Neatly Dressed Including Providing Barricading, Danger Lighting Guarding As Directed In : B)All Types Of Ordinary Rock Including All Types Of Laterite Rock, Blasting Prohibited , Earthwork In Excavation By Mechanical Means (Hydraulic Excavator)/Manual Means In Foundation Pipeline Trenches Drain (Not Exceeding 1.5 M In Width Or 10 Sq.M. On Plan) Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Within A Lead Of 50 M. A All Kinds Of Soil , Earthwork In Surface Excavation Not Exceeding 30 Cm Depth(But Exceeding 1.5 M Width As Well As 10 Sq.M On Plan) Including Disposal Of Excavated Earth Beyond Work Site For All Leads Lift Disposed Earth To Be Leveled And Neatly Dressed In: B Hard Soil , Rubble Packing With Hard Laterite Stone Under Floors Including Watering Ramming And Consolidating Etc. In Pipeline Trenches And Other Foundations Complete. , Providing & Laying Cement Concrete 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Granitic Or Basaltic Stone Aggrt. 20 Mm. Nominal Size) Excluding Cost Of Centering, Shuttering And Finishing In: A) All Works Upto Plinth Level , Centering & Shuttering Including Strutting, Propping & Removal Of Forms For : Foundations, Footings, Bases For Columns , Laterite Masonry In Neatly Dressed Stones Of Size As Specified In Cement Mortar 1: 4 (1 Cement : 4 Coarse Sand) In Foundation And Basement. , 18Mm Cement Plaster In Two Coats Under Layer 12Mm Thick Cement Plaster 1:5 ( 1 Cement : 5 Coarse Sand) And Top Layer 6Mm Thick With Cement Plaster 1: 3 (1 Cement : 3 Coarse Sand) Finished With Sponge. , Providing & Laying Of Minimun 80Mm Thick Factory Made Shot Blasted Cement Concrete Interlocking Paver Blocks Of Minimum M40 And Above Grade Made By Heavy Duty Block Making Machine With Strong Vibratory Compaction And Of Approved Size And Design/ Shape Laid In 50Mm Thick Compacted Bed Of Coarse Sand, Filling The Joints With Coarse Sand Etc. All Completed As Per The Direction Of Engineer-Incharge. The Product Should Comply With Is 15658: 2006 And Manufactured By Iso 9001: 2008 Certified Plant.1)Size: 210Mm X 150Mm X 80Mm Thick (Type: Rectangular Type Pavers) , Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) (Square Hollow Section (Shs) Is4923 /Rectangular Hollow Section (Rhs) Is4923/ Circular Hollow Section (Chs) Is1161 Closed Structural Steel Of (Sail, Tata. Vizag, Jsw ,Apollo Steel Ltd.) Make (Min Yeild Stress 310 Mpa)) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer, Including Welding And Bolted With Special Shaped Washers Etc. Complete. , Supplying And Fixing Pre-Cast Cement Concrete Kerb-Stones(Factory Made,The Factory Should Be Iso Certified And Registered Under Dirctorate Of Industries, Govt. Of India) Of M-20 With 20 Mm Nominal Size Granitic/Basaltic Aggregate Properly Consolidated By Mechanical Plat-Form And Vibrators With Smooth Finish Including Fixing At Site Complete As Per Specification.A)Size 30 Cm L X 50 Cm H X 15 Cm T , Painting Three Or More Coats With Acryllic Exterior Paint Of Approved Brand And Manufacture (Such As Weather Shield,Apex) Including Applying One Coat Of Cement Primer And One Coat Of Surface Treatment Etc. Complete. , Providing & Fixing Of Seater Made Of Cast Iron And Powder Coated Complete As Per Direction Of Engineer-In-Charge, ManufacturerS Specification & Drawing. , Providing And Fixing Of A Artificial Cricket Pitch , Monia Tiles , Supplying And Installation, Fixing Nylon Net All Around Verticle Net Garware Make Or Its Equivalent 50Mmx50mmx2.50Mm Thick As Approved By The Engineer-In-Charge.Top Net 50X50mm X1.75Mm Thick.Wirerope Complete Fixing Of Wire Ropes Of 5Mm With Turnbuckleand Dog Clips. Etc. Complete .( Contractor Has To Bear All The Cost And Arrange All Permissions For Interstate Transit Of Goods Including Storage Of The Goods). , Triangle Brush And Handy Turf Brush Set , Sbr Enfield , Supplying And Erecting Integrated Led Round Burial Light 6W Ip65 & Ik10 Class Having Pressure Die-Cast Housing, Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 85 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 100-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 50,000 Hrs At L50b50 , Slat Spray Tested For 500 Hrs. Including Making Of Recess Of Appropriate Size For Flushing Into Surface With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen/W, Cri70, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver With U Shaped Bracket With Minimum 2 Years Warranty As Per Specification No. Fg Odf/Fl. , Supplying And Erecting Led Square / Circular Max. 14 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 1500 Lumens, Min. Efficacy Of 110 Lumen/W, Cri80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50,000 Hrs At L70b50 Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With Minimum 2 Years Warranty As Per Specification No. Fg-Idf/Led. , Supply And Erecting Of 9 Inch (225 Mm Sweep) Exhaust Fan With Double Ball Bearings, 1400 Rpm, Complete With All Accessories(A) Cat A. , Supplying And Erecting Concealed Type Foot/Step Light Max. 5W Having Ip67, Ik10 Rated Pressure Die Cast Housing Having System Lumens Output Of Min. 500 Lumens, Min. Efficacy Of 100 Lumen/W, Cri80, Cct Upto 5000K, Beam Angle Of 110 Deg., Thd10%, Sdcm5, P.F. 0.95, Operating Range Of 230-270V, Surge Protection Of 2.5 Kv, Life Class Of 25,000 Hrs At L70b50, Including Driver By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface With Minimum 2 Year Warranty. , Supplying And Erecting Integrated Led Post Top 45W Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 105 Lumen/W, Cri80, Cct Upto 6500K, Thd10%, P.F. 0.90, Operating Range Of 140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30,000 Hrs At L50b50 , Including Driver Complete With Minimum 2 Year Warranty As Per Specification No Fg-Odf/Pt. , Supply And Erecting Of 3 Mtr High Decorative Pole With Base Plate And Pole Cap , Supply Of 3 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size.3 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Copper Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 4 Sq.Mm , Supply Of 4 Core Armoured Pvc/Xlpe Insulated, Pvc Sheathed Aluminium Conductor Cable Of 1.1 Kv Grade With Isi Mark Conforming To Is:1554(Part I) ,Is:7098(Part I) With Latest Amendments Of Following Size. 4 Core 50 Sq.Mm , Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Rcc/Hume/Stoneware Metal Pipe, Etc. Complete As Required. , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm In The Existing Masonry Open Duct, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Not Exceeding 25 Sq.Mm On Surface, Etc. Complete As Required , Laying Of One Number Pvc Insulated And Pvc Sheathed/Xlpe Power Cable Of 1.1 Kv Grade Of Size Exceeding 25 Sq.Mm But Not Exceeding 120 Sq.Mm Direct In Ground Including Excavation In The Form Of A Trench As Per Cable Trench Drawing Provided By The Engineer-Incharge,Sand Cushioning With Screened Sand Bed Of 20Mm Thick , Protective Covering With Bricks Placed Breadth-Wise On Top Of Cable All Over The Run( The Brick Protection Shall Cover The Cable And Project Atleast 5 Cms Over The Sides Of The Cable) And Backfilling The Excavated Earth Without Stones Or Hard Material And Making The Surface Proper With 15 Cm Crown On The Top Complete As Required. , Supplying And Making Cable End Terminations With Brass Compression Gland And Copper Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required.. 4 Core 4 Sq.Mm , Supplying And Making Cable End Terminations With Brass Compression Gland And Aluminium Lugs For Folowing Sizes Of 4 Core Pvc Insulated Pvc Sheathed/Xlpe Aluminium Conductor Cable Of 1.1 Kv Grade, Complete As Required. 4 Core 50 Sq.Mm , Supplying And Laying (Including Excavation Of Suitable Width & Depth Up To 90 Cm) 50 Mm Outside Dia. Double Wall Corrugated Pipes (Dwc) Of Hdpe For Enclosing Cable Below Ground/Road Surface, To Required Depth Complete. , Supplying&Erectingwatertightterminalboxof1.6Mm(16Gauge)Crcasheet Of Size 200 X 150 X 150 Mm. Complete On Pole As Per Specification No. Cb-Sb , Supply And Providing Chemical Earthing System (Pipe In Pipe Type) With Outer Pipe Of The Electrode Having Minimum 50Mm Diameter As Per The Enclosed Specifiations And Drawing.The Outer And The Inner Hot Dip Galvanised Ms Pipes Shall Conform To The Specifications And The Space Inbetween Shall Be Filled With Highly Crystalline Conductive And Anti- Corrosive Mixture Conforming To Is-3043. The Earth Electrode Shall Be Cpri Tested. The Scope Of Work Includes Boring( 300Mm Dia Mimnimum)/Exvavation Of Soil/Hard Rock, Refilling With Required Quantity Of Back Fill Compound/Ground Resistance Enhancement Powder Of Requisite Quantity, Compaction, Constuction Of Masonary Chamber Etc Complete As Required To Obtain The Desired Value. Aluminium Tag With Embossed Earthing Value Shall Be Permanently Attached To The Pipe Electrode(B) 2 Metres Length Electrode , Providing And Fixing 25 Mm X 5 Mm Gi Strip On Surface Or In Recess For Coneections Etc. As Required , Supplying And Laying 8 Swg Copper Wire At 0.5 M Below Ground Level For Conductor Earth Electrode Including Soldering Etc. As Required , Supply Of Back Fill Compound/ Groung Resistance Enhancement Powder Conforming To The Enclosed Specifications. , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Light Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following :Auto Manual Swithc 1 Nos Street Light Control 32A 4Pole Contractor 4 Nos. Manual Control Switch With 4 No. / Nc Aux. Contacts One Electronic Timer With 10A Output Contactors For Operating Four Contactors Timer Unit Shall Be In A Separate Compartment With Glass Seal Provision If Any. And Possible To Adjust The Time Settings .3 Phase Meter And Mcb Arrangment With Modem And As Per Ged Requirement . Along With Necessary Stand And Earthting Brought Forward For Necesaary Connection On Both Side Of Panel Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor, Selector Switch Shall Be Protected By 2 Amps Tp Mcbs. 1 .Sets1breaker On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Dg Incomer63 Amps 4Pole,36 Ka Mccb, Ats 63 A With 415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 4 Outgoing 32 A 4 Pole Mcb ,36Ka Set1 Spare Feeder63 Amps 4 Pole Mcb ,36 Kaset 1 ,25 Amps 4 Pole Mcb , 36 Ka Set1 , , Design Fabrication , Supply , Installation , Testing And Commissioning Of Outdoor Feeder Pillar Panel Made Out Of 14 Swg Crca Sheet , Degreased , Derusted And Painted With Two Coats Of Red Oxide Primer And Two Coats Of Siemens Grey Epoxy Paint And Conforming To Ip 54 Class Of Protection . The Panel Shall Be Suitable For Three Phase 415V , 50 Hz. , Four Wire Ac System And Shall Comprise Of The Following : Incomer63 Amps 4Pole,36 Ka Mccb, With Neutral Contactor,On / Off / Trip Indicating Lights With Control McbS.Set1ryb Lamp Mcb Set1busbar 100 Amps ,415 V Tpn 50 Hz Aluminium Bus Bars With Heat Shrinkable Insulation Sleeve.Set 20 Outgoing 32 A Four Pole Mcb ,36Ka Set 35 63 Amps 4 Pole Mcb ,36 Kaset 10 ,25 Amps 4 Pole Mcb , 36 Ka Set 10 , Supplying And Fixing 6 A To 32 A, C Series Mcb Suitable For Lighting And Other Loads Of Following Poles In The Existing Mcb Db Complete With Connections Testing And Commissioning Etc As Required.(A) Sp, Cat A , Supplying, Erecting, Testing And Commissioning Of Diesel Generating Set With Alternator Of 58.5 Kva Output Continuous Rating, 3 Phase, 415 V, 50 Hz, 0.8 P.F., A.C. Supply, A Totally Enclosed Air Cooled / Liquid Cooled Multi-Cylinder Diesel Engine Developing Suitable Bhp At 1500 Rpm With 10% Overload For 1 Hour In 12 Hours, Along With Standard Accessories, Self-Excited, Self-Regulated, Screen Protected Alternator With Static Excitation System Running At 1500 Rpm As Per Is 4722-2001 With Voltage Regulation +/- 5 %, With Performance Class G2/G3 And Maximum Fuel Consumption 9.98 Ltr/Hr @75% Loading. Both The Engine And Alternator Direct Coupled On A Common Fabricated Steel Base Frame And Mounted On Anti-Vibrating Pads, With Standard Control Panel Comprising Meters, Switchgears, Indicators Connected With Suitable Wires/Cables, The Complete Set Enclosed In Composite Acoustic Enclosure As Fully Assembled Integral Unit Made Of 16 Swg Crca Sheet, Sound Absorbing Material To Restrict Sound Level Up To 75 Db At 1.0 M, Provided With First Filling Of Oil, Diesel Not Less Than 150 Ltr Etc., On Provided M20 Grade cement concrete Foundation As Per Specification No. Gen-Dg
Contract Date: Jun 17, 2026 Contract Value : 1.20 Crore
Statutory Bodies & Commissions/Committees No of Bidders 2
8.
Educational and Research Institute #11161433 Price Bid
Procurement Of Equipment, Instruments, Machinery, Tools Etc. Related To Laboratories And Workshops Of Electronics And Telecommunication Engg., Engineering Physics, Engineering Mechanics Of Mirik Government Polytechnic, Mirik, Dist. Darjeeling, 734214 , Spherometer (Screw Pitch 0.05 Mm And Lc 0.005 Mm) , Concave Mirror (Focal Length 20 Cm) , Convex Mirror (Focal Length 20 Cm) , Concave Surface (Focal Length 20 Cm Diameter 50 Mm) , Hooks Law Apparatus (Consisting Of 30 Cm Long Mirror Scale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand) , Mercury (Distilled Liquid Mercury, Grade Std.-Biotech Grade) , Flywheel Apparatus (Thickness: 4.4 Cm Diameter :20 Cm) , Cantilever (Length 100 Cm, Hook At One End, C Clamp) , Light Weight Hanger (Metal Slotted Weight Mechanics Physics Experiment Equipment Set With Hook With Weight Of Each Mass Of The Order Of 50Gm Or 100 Gm) , Inverse Square Law Apparatus (Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter) , Stopwatch (Digital Stopwatch With Ms Count) , High Resistance Box (Resistance Box Plug With 1 To 10 K Ohm Resistance) , Winch Crab Single Purchase With Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut.String, Weight Box With Pan. ] , Winch Crab Double Purchase Without Weight [Experiment Set Up Winch Crab Single Purchase- Fitted With Heavy Cast Iron Wall Brackets The Grooved Wheel Is Of 25 Cm Diameter And Gears Are Machine Cut. ] , Worm And Worm Wheel Single Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Worm And Worm Wheel Double Without Weight [Experiment Set Up Consisting Of Machine Cut Worm Gear Of 25 Cm Diameter, Carrying A Metal Drum On 12 Cm Diameter, And Machine Cut Worm On Steel Spindle Carrying A 12 Cm, Complete With Effort Pulley, String With Pan.] , Wheel & Axle Simple Without Weight [Standard Setup For Lab.] , Simple Screw Jack With Weight [Experiment Set Up Screw Jack ( Weights)All Metallic Construction Accurately Machine Cut Screw With A Pitch Of 5 Mm Carrying A Double Fanged Turn Table Of About 20 Cm Diameter. Fitted On A Heavy Cast Iron Base And Complete With Two Adjustable Pulleys, Cord And Hook. Weights Are Included.] , Combined Inclined Plane & Friction Slide Apparatus Iron Base & With Weight [Standard Setup For Lab.] , Parallel Forces Apparatus [Experiment Set Up Simple Supported Best Type Supported At Its End. For Verification Of Condition Of Equilibrium Of Parallel Forces, Law Of Lever & Forces On Beam Etc. Consisting Of Two Compression Thrust Type 10 Kg Tubular Spring Balances Fixed On Wooden Polished Board, A Wooden Beam With Steel Back Plate. Complete With Two Strups, Hooks & Two 10Kg Weights. ] , To Verify Lami’S Theorem [Gravesand Apparatusboard: Wooden With Metal Base Pulley: Z-Pullies (2 Nos) With Adjustable Distance Weight Set: 5X50 G (3 Sets). ] , Simple Jib Crane Apparatus Iron Stand With Weight [Experiment Set Upwith Consisting Of A Tubular Compression Balance, Pivoted About An Axis Fitted To The Base. The Tie Chain Has An Adjustable Angle Bracket And Fitted With A 10Kg Extension Balance. Completion Wooden Base With 1.2 Meter Jib. With Weights. ] , Mini Drafter, T Square, Protractor, Set Squares, Compass, Divider [Made Out Of Wood. To Be Used In Chalk Board] , Model Of Geometric Constriction (Solid Cube, Solid Primed, Cylinder, Cone, Hexagon, Tetrahedron ) [Made Out Of Wood. To Be Used In Chalk Board] , Amplitude Modulation And Demodulation Trainer Kit [Message Signal:100 Hz To 2.8 Khz, Carrier Signal 28 Khz To 108 Khz,Modulation : Balanced Modulator, Amplifier : Op Amp Based, Demodulation : Diode Detector & Lpf(6Th Order)] , Frequency Modulation Anddemodulation Kit [On-Board Message Signal With Variable Amp/Freq,On Board Carrier Signal Fm Modulation Using Xr 2206Ic,Demodulation Using Pll Detector And Lpf 4Th Order Lpf,Internal Power Supply +5V , +12V/ 500 Ma] , Super Heterodyne Am Radio Receiver Trainer Kit To Measure Sensitivity, Selectivity And Fidelity [On Board Variable Capacitor Tuning,Receiving Antenna,Local Oscillator,Bfo, Rf Amplifier, Mixer,If Amplifiers, Detectors, Agc,Audio O/P Amplifier, Speaker.Frequency Range: 400Khz To 1700Khz,If Frequency: 455 Khz.] , Pam, Pwm And Ppm Modulation And Demodulation Trainer Kit [Provides Sine Waveform Output Of 250Hz, 500Hz, 1 Khz, And 2 Khz With Amplitude Adjustments Of 0 - 5Vp-P. Switch Selectable Sampling Clock Of 4, 8, 16, 32 Khz. On-Board Features Analog Sample Circuit/Output, Sample & Hold Circuit/Output, Flat Top Circuit/Output, 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz.] , Analog Signal Sampling & Reconstruction Trainer Kit [±15V D.C. At 100Ma, Ic Regulated Power Supply, A.F. Signal Generator For Modulating Signal.Sampling Clock Generator To Provide Sampling Clock And Gate Pulse. Modulator Circuit For Flat-Top Natural And S/H Circuit. Demodulator Circuit To Reconstruct Input (Sinewave)] , Telephone Receiver Trainer Kit [Line In Section : One Dot Line Connection Port.Handset : One Handset Connection Port. Keyboard : 4X3 Matrix Keyboard.Dialer : Tone And Pulse. Facilities : Redial Up To 32 Digits, Mute, Redial, Flash, Pause Switches.Indicators : Line In, Hook, Tone And Ringer, Call Mute Section.Control : Ringer Volume Control, Ringer Speed Control.Speech Path : Fully Non-Blocking.Dial Pulse Ratio : 10 Pps + / - 10%.] , 100Mhz Digital Oscilloscope [Bandwidth: 100 Mhz, 2 Analog Channels+ Ext With Probes Included Rise Time: =3.5 Ns, Real-Time Sample Rate Of 1 Gsa/S 1% Dc Gain Accuracy Should Support Rs232/Uart, I2c And Spi Bus Triggers And Decodes Usb And Ethernet Connectivity] , 30Mhz Analog Cro [Dual Trace Dual Channel Oscilloscope. Bandwidth: 20Mhz. Full Bandwidth Sweeping Circuit , Tv-H / Tv-V Synchronization And Trigger-Lock To Observe All Kinds Of Signals Stably. Y Deflection Operation: Y1, Y2, Alt, Chop, Add, Mode.Horizontal Sweep Mode: Auto, Trig, Lock, Single.X-Y Mode Input: X-Axis Yi And Y-Axis Y2.] , 2 Mhz Function Generator [Frequency: 1Hz – 2 Mhz Sine, Square, Triangle, Ttl Output] , Digital Storage Oscilloscope (100 Mhz) [Bandwidth 100 Mhz, Channels: 2+, Display: Tft Color Lcd Of Suitable Size (Capacitive Touchscreen). Sampling Rate: 1 Gsa/S Real Time, Sampling Mode: Normal, Average (2, 4, 8, 16, 32, 64, 128, 256), Peak Detect. Mathematics: A+B, A-B, A×B, Fft (Fast Fourier Transform). Fft Windows: Rectangle, Hanning, Hamming, Blackman. Auto Measurement: Vpp, Vamp, Vmax, Vmin, Vtop, Vbase, Vavg, Vrms, Overshoot, Preshoot, Freq, Period, Rise Time, Fall Time, +Width, -Width, +Duty, -Duty, Delay1-2 (Rise), Delay1-2(Fall) ] , Trainer Kit For Rectifier With And Without Capacitor Filter For : — (A) Half-Wave Rectifier, (B) Full-Wave Rectifier, (C) Bridge Rectifier [Transformer Rating : 9-0-9V/200Ma, Rectifiers : Half Wave; Full Wave - Bridge, Center Tapped Rectifier,On-Board Dc Voltmeter : 0 - 20V,On-Board Ac Voltmeter : 0 - 20V,Load : Variable Resistive Load 10K,Filter Circuit : In-Built- Capacitor (3Nos.),In-Built- Inductor (1No.),Input Line Voltage : 230V Ac ± 10%, 50Hz] , Push-Pull Amplifier Trainer Kit [I.C Regulated Power Supply : +6 V.Digital Ac Voltmeter: 0 – 20 V.Digital Ac Milliammeter : 0 – 200 Ma.Set Of Resistances.Set Of Capacitors.Two Transistors Cl 100 And Ck 100.Connecting Wire.] , Fet Characteristics Trainer Kit [Variable Dc Regulated Power Supply Of 0-5V At 250Ma. Dual Range Dc Voltmeter Of 1.5V/15V.Dc Ammeter Of 0-20Ma.] , To Determine Frequency Response Characteristics Of Rc Coupled Amplifier Circuit And Calculation Of Bandwidth, Midband Gain, Input Impedance And Output Impedance For: (A) Single-Stage Amplifier (B) Double-Stage Amplifier [Sine Wave Oscillator 15Hz To 150Khz In Four Ranges With Amplifier & Amplitude Adjustable.Three Decade Resistances Bank In Steps Of 1K, 10K & 100K Per Steps Total Step 30.Two Pnp Transistors.] , Mosfet Characteristics Trainer Kit [On Board Ammeter And Voltmeter,Dual Variable Dc Power Supplies,On Board Mosfet And Fet With Resistors To Perform Experiments] , To Study The Input And Output Characteristics And To Find The H-Parameters Of A Bjt For : — (A) C-E Configuration, (B) C-C Configuration, (C) C-B Configuration [Power Supply 1) 0-1V Dc 2) 0-10V Dc.Meters Dc 65Mm Four Dial V, V , Ma Ua/ Ma.Transistor Cl100/ Similar] , Component Development System [Power Supplies On Boards 0-15 V And 0-30 V, 250 Ma Each Variable.Fixed Dc Regulated Power Supplies 15 V/250 Ma And 5 V/250 Ma.Ac Power Supply 15-0-15 V For Rectifier Applications.Various Components On The Trainer Set. ] , Kcl & Kvl Trainer Kit [Two Dc Ic Regulated Power Supplies 0-12 V/150 Ma, Two Mr65 Square/Digital Meters For Voltage & Current Measurement, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Power Cords 230 V, 50 Hz] , Thevenin’S And Norton’S Theorems Trainer Kit [Power Supply 2?3?0?V, Regulated & Short Circuit Proof Variable Dc Voltage Source – 01 No. Fixed Resistance Of Different Values. Dc Voltmeter.Dc Ammeter. Glass Fuse For Short Circuit Protection. On/Off Switch With Indication Light. Patch Cords Suitable To The Terminals With Board For Easy Interconnection.All Above Accessories Will Be Fitted On Bakelite Sheet Fixed On Box.] , Superposition Theorem Trainer Kit [Instrument Comprises Of Two Fixed Output Dc Regulated Power Suppliesof 12V & 5V At 500 Ma Current, Three Moving Coilmeter, Circuit Diagram Printed On The Front Panel & Connections Ofsupplies, Meter & Resistances Brought Out At 4Mm Sockets. ] , Maximum Power Transfer Theorem Trainer Kit [Ammeter 30Ma Dc. Voltmeter 12V Dc. Power Supplies: Dc Supply Ic Regulated 0-12V Dc, 150Ma. Operated On Mains Power 230V, 50Hz +10% Components Are Mounted On The Panels Are: Resistances 2Watts Variable Resistor Voltage Control Through Potentiometer. Fuse For Short Circuit Protection. Patch Cords 4Mm.] , Reciprocity Theorem Trainer Kit [Instrument Comprises Of One Fixed Output Dc Power Supply Of 12V At 300 Ma Current, Two Moving Coil Meters, Circuit Diagram Printed On The Fornt Panel & Connections Of Supplies, Meters & Resistances Brought On Terminals.] , Series And Parallel Resonant Circuit Trainer Kit [Analog Meters: Ammeter 20Ma Ac. Voltmeter 20V Ac. Components Mounted On The Panels Are: 3 Nos. Of Resistors Selected By Rotary Switch. 3 Nos. Of Capacitors Selected By Rotary Switch. 3 Nos. Of Inductors Selected By Rotary Switch.] , Low Pass And High Pass Filter( Rc & Lc) Constant K Type Trainer Kit [Instrument Comprises Low Pass Circuit Rc Type Instrument Comprises Low Pass Circuit Lc Type Instrument Comprises High Pass Circuit Rc Type Instrument Comprises High Pass Circuit Lc Type Instrument Fitted In Highly Shockproof Plastics Box] , T And ? Type Attenuator Trainer Kit [Instrument Comprises Ofdc Ic Regulated Power Supplies 0-15V/150Ma. Two Mr65 Square / Digital / Round Meters For Voltage & Current Measurement. T And Pie Network Provided On The Board. Variable Resistor Using Band Switch Is Mounted On The Board. Instrument Fitted In Highly Shockproof Plastics Box. Sufficient No Of 4Mm Patch Cords For Interconnection Instruction Manual For Student Workbook. Power Cords 230V, 50Hz] , To Study Standing Wave Pattern For A Transmission Line Of Finite Length With: (A) Open Termination, (B) Short Termination, And © Matched Termination. [Transmission Line : Coaxial Cable 100M ( 25M X 4 Nos) Impedance Matching Resistance : 0 To 100 ( 02 Nos ) Test Generator : 1. Sine Wave : 4 Khz To 4 Mhz. 2. Square Wave : 10 Khz. Interconnections : 4 Mm Sockets On All Input / Output Connections. Test Points : 10 On Board Circuit Mimic : Illustrates Functional Blocks For Ease Of Experimentation Power Requirement : 230V 10% 50Hz, 1 Ac. Accessories Provided : I. Set Of Patch Cords. Ii. Bnc To Bnc Cable. Iii. Bnc To Crocodile. Iv. Detailed Instruction Manual.] , Digital Trainer Kit (Experiment 1. -To Verify The Truth Table Of Not, Or, And, Nand, Nor, Xor, X-Nor With Ttl Logic Gates And Cmos Logic Gates. Experiment 2.- To Realize Different Boolean Expressions With Logic Gates. Experiment 3.-To Realize Half-Adder, Full-Adder, Subtractor, Parallel And Serial Full-Adder. Experiment 4-To Design 1’S Complement, 2’S Complement And 9’S Complement Adder-Subtractor.) [Dc +5V , 400Ma; Dc +12V, 250Ma; Dc -12 V, 250Ma, Dc0 To + 30V: Variable 100Ma,Ac Output: 12V-Ct-12V, 150Ma; Logic Data 8-Bit Debounced Set/Clear Ttl Output With Bicolour Led; Clock Generator I Hz To 200Khz Variable & Manual, Ttl & /Ttl(Complement) With Bicolour Led;Logic Probes 8-Bit 3-State Led Display High, Low, High Impedance; Function Generator Sine, Square, Triangle, 1 Hz To 250 Khz;Bread Boards : 3 X 820 Tie-Points; Total Short Circuit Protection From Any To Any Point On Board] , Complete Setup To Implement The Truth Table Of Encoder,Decoder, Multiplexer And De-Multiplexer. [The Trainer Kit Should Be Able To Verify The Truth Tables Of Truth Table Ofencoder,Decoder, Multiplexer And De-Multiplexer.] , Complete Setup To Design/Construct Parity Generator, Checker And Comparator. [Industry Standard Specification To Perform Relevant Experiments. ] , Flip Flop Trainer Kit [Kit For Verification Of Jk, Sr, D, And T Flip-Flop Truth Tables] , Complete Setup To Design / Construct Binary Synchronous And Asynchronous Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design / Construct Programmable Up/Down Counter. [Industry Standard Specification To Perform Relevant Experiments. ] , Complete Setup To Design Controlled Shift Register And Study Their Function. [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Study Different Memory Ics [Industry Standard Specification To Perform Relevant Experiments. ] , A/D & D/A Converter Trainer [Industry Standard Specification To Perform Relevant Experiments. ] , Trainer Kit To Interface Ttl And Cmos Ics. [Industry Standard Specification To Perform Relevant Experiments. ] , 8051 Trainer Kit [Operating Frequency : 10Mhz Crystal,40-Pin Ic Base | 40Pin-Zif Socket,2×16 Char Lcd Display,32 I/O Pins,32Kb-Sram,32Kb-Eeprom.] , Ct-31/51 Or 8031/51 Microcontroller Trainer Kit With Led Display, Usb Interface & Inbuilt Power Supply [Operating At 10/12 Mhz, On Board 8K Ram,8/16K Bytes Of Eeprom,48 I/O Lines,Hexadecimal Keyboard And Six Seven Segment Displays,Rs-232C Interface,Usb Interface] , Ct-31/51Lcdadu8031/51 Microcontroller Trainer With Lcd Display, Usb Interface, Adc, Dac& Inbuilt Power Supply [Trainer Based On 8051/89C52 Microcontroller.On Board 32K Ram.64 K Bytes Of Eeprom.20 X 2 Lcd Display.48 I/O Lines. Onboard Adc & Dac.] , Adc Interface Module [Usb Interface, Adc Module Module 10 Channel 12Bit Ad Sampling Data Acquisition Stm32 Uart Communication Adc Module] , Dac Interface Module [Operating Voltage 2.7-5.5 V. Interface Type I2c. Resolution 12 Bits.] , Lcd Display Module [Display Contents :16 * 2 Characters (5*8 Dots ). Lcd Size :80 X 36 Mm .Lcd Thickness :9.5 Mm.] , Keyboard Interface Module [5X4 Keys Matrix Keyboard. ] , Dc Motor Controller Module [Driver Module : L298n. Motor Supply Voltage (Max.): 46V.Motor Supply Current (Max.): 2A. ] , Stepper Motor Controller Interface Module [Robocraze Stepper Motor(28Ybj-48 Dc 5V 4 Phase 5 Wire) + Uln2003 Driver Board Compatible With Arduino] , Trafic Light Controller Module [Led Traffic Lights Signal Module/Digital Signal Output Traffic Light Module] , Temperature Measurement Module [Electrobot Dht11 Digital Temperature & Humidity Sensor Module For Arduino And Rpi] , Operational Amplifier Trainer Kit ( Ic 741 ) [Inbuilt Variable/Fixed Dc Regulated Power Supplies.Output Voltages : 0-5Vdc (2Nos.) (Variable), +12Vdc (Fixed).Transistor & Components Provided Ic : 741.Transistor : Cl 100 (Npn).] , Active Filter Trainer Kit (Lpf, Hpf, Bpf) [Opamp Based First Order Lpf, Hpf, Bof Trainer Kit (Mi-A14)] , Application Of Ic555 Timer Trainer Kit (Astable & Monostable Mv) [In-Built Regulated Dc Power Supply.On Board Manual Pulse Generator For Triggering The Monostable And Bistable Circuit.Inbuilt Led Output Indicator.Symbols And Diagram Are Printed On Glass Epoxy Pcb.] , Opamp Based Oscillator Trainer Kit ((A) Hartley, (B) Colpitt, (C) Phase Shift, (D) Wein Bridge) [Op-Amp Oscillator Trainer Mi-A13. Frequency 50-60 Mhz.] , Crystal Oscillator Trainer Kit (741 Based) [Industry Standard Specification To Perform Relevant Experiments. ] , Function Generation Kit (Using Icl8038) [Icl8038 Function Signal Generator Sine Triangle Wave Kit Diy Professional K5e8.Uses Icl8038 And High-Speed Op Amp, Higher Accuracy. Low Distortion Sine Wave: 1%.] , Voltage Regulator Trainer Kit (Using Ic723) [0-35V D.C. At 250Ma, Countinously Variable Unregulated Power Supply.D.C. Milliammeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 50Ma And 250Ma.D.C. Voltmeter, 65Mm Rectangular Dial With Switch Selectable Ranges Of 10V And 40V.Ic 723 Fitted On Base.Three Potentiometers.] , Function Generator Trainer Kit [Frequency Ranges: 1? Hz To 1?0? Hz, 1?0? Hz To 1?0?0? Hz Fuse:3?5?0? Ma, Slow Blow Automation Grade: Manual Power Supply:Max 2?3?0?V Ac, 5?0? Hz +/- 1?0?%] , Maxwells Bridge Trainer Kit [The Kit Contains A Bridge With Provision For Connections Of Capacitors And An Unknown Inductor. In Built Ac Supply [ 1 Khz And 2 Vpp ] And Dc Supply [ +5 V ] On Board. Two Nos Dial Resistances [ 50 Ohm To 200 Ohm ] And [ 1 Ohm To 11 Ohm ] In Step. A Dc And Ac Null Detector Using Selector Switch. A Dial Type Variable Capacitor [ Range 0.2 Uf Ro 1.2 Uf ] And Six Nos. Unknown Inductors [ Range 1 Mh To 12 Mh ].] , Lvdt Trainer Kit [Excitation Source Built In Ac Source 2.5 Khz Sine Approx. L.V.D.T. In Non Metallic Structure. Micrometer One (For Displacement) Displacement Range 10Mm. Test Points Sockets At Different Places For Signals. Potentiometer Two For Zero & Calibration Adjust Display (Mm) 3.5 Digit Digital Power Supply Ic Regulated Phase Detection Balanced Demodulator Power Supply Short Circuit &Overload Protected Mains 230V/50Hz Ac] , Strain Gauge Trainer Kit [Strain Gauge: 4 Mounted Upon Cantilever 150X3.5X3.5Mm, Stable Dc Voltage For Strain Gauge Bridge, Opamp Based,Precision Instrumentation Amplifier With Variable Gain,Potentiometer For Zero And Calibration Adjust,3.5 Digit Display For Strain/Weight, 230V 50Hz Ac] , Temperature Transducers Kit Using (A) Rtd (Pt-100) (B) Thermistor. [12 - 0 - -12 V 500Ma To Drive Digital Integrated Circuitry. 5 - 0 - -5 V 250Ma To Drive A To D Converter Signal Conditioning And Amplifying :Analog To Digital Converter. Display : 31/2 Digit Led Display Of 200 Mv Fsd Initial Set : Single Turn Potentiometer To Set Initial Temperature ( Room Temperature) Final Set : Single Turn Potentiometer To Calibrate The Instrument ( Max. Temperature) Select : 2 Way Rotary Switch To Select Rtdand Thermistor. Power On : Rocker Switch To Control Power Supply To The Instrument.] , Calibration Of A Single-Phase Energy Meter By Phantom Loading Trainer Kit [Usage/Application: Lab Experiment Connection:4?-Mm Patch Cord Single Phase Automation Grade:Manual Power:2?0?0? W Voltage:2?2?0?-2?4?0? V] , Calibration Of A Voltmeter Using Crompton Potentiometer Trainer Kit [This Trainer Is Supplied Along With Highly Regulated Dc Power Supplies To Operate The Unit. Further To Calibrate Pmmc Meters, Necessary Ratio Boxes Also Provided. Resistors Used In This Unit For Coarse And Fine Are Very Standard Type Made Of Manganin. This Enable The User To Measure The Potential In A Circuit Close To Micro Volts. Necessary Schematic/Wiring Diagram Printed On The Panel To Follow And Conduct Experiments. User Manual And 4Mm Patch Cords Supplied. Accessories Included: Necessary Dc Power Supplies, Ratio Boxes & Galvanometer Are Provided Alongwith The Unit.] , Cro Demonstration Kit [Crt : 6Rectangular Screen With Internal Graphical 8X10 Division (1Div-1Cm) Vertical Deflection Display : Ch1, Ch2, Add, Alt & Chop Deflection Factor : 5Mv/Div To 5V/Div +3%, 1Mv/Div To 1V/Div, +5% (X5), 10 Steps Rise Time : <17.2Ns Maximum Input Voltage : 250 (Dc + Ac Peak Value) When <1Khz (250V, Dc +Ac) Input Coupling : Ac, Dc & Gnd Polarity Selection : + (Ch2 Only) Display Mode : 1, 10 & X-Y Horizontal Deflection Time Base : 0.2Us/Div To 0.2S/Div, 9 Ranges Sweep Expansion : X10 Accuracy : +3% Triggering Mode : Auto, Norm, Tv-V, Tv-H Triggering Source : Int, Line & Ext. Trigger System Auto : 20Hz-20Mhz Norm : 0.5 Div Int, 0.5 Vp-P Ext Tv-H : At Least 1 Div Or 1 Vp-P Input Impedance : 1Mohm X-Y Phase Difference : <3 Degree, Dc-50 Khz Calibration Waveform : Frequency 1Khz 2%,Voltage 0.5 V 1%, Block Diagram Printed On The Top Panel, Power Requirement: 220 Vac +10% , 50 Hz] , Q-Meter Kit Formeasurement Ofq Of Coils. [Inductance Range:199.9Mµh-19.99H Resistance Range (Ohm):19.99O-19.99M? Capacitance Range:199.9P-1.999?F Capacitance Accuracy: ±(1%±2) Digital Lcr Bridge Meter Power:220 Volts/50Hz ±10%] , Spectrum Analyzer Trainer Kit [Industry Standard Specification To Perform Relevant Experiments. ] , Public Address System Trainer Kit [To Test The Performance Of Loudspeaker And Microphone; Power Output: 100W Rms At 10% Thd Pre-Amplifier Output: 200Mv; Line Output: 1V/ 1K?; Input Channels: Mic: 2Nos; Frequency Response : 65 Hz To 15 Khz +/- 3Db Tone Controls : Bass, Treble, Master 1Control; Speaker Outputs : 4 , 8 , 16 , 70-100V Line Matching; Speakers : 2 Nos; Microphones : 2 Nos(Dynamic Microphone)] , Demonstration Kit Of Black & White Tv Trainer [To Learn The Practical Aspects And Faults Which Would Occur Often In The Black And White Tv. All The Fault Switches Are Provided To Conduct Fault And Observe The Output. The Test Points Are Provided To Determine The Voltages At The Different Sections Of The Tv And Observe The Signal Output Of The Various Sections. The Output Is Monitored On A 20” Picture Tube.] , Demonstration Kit Of Colour Pattern Generator For Colour Tv [They Should Be Able To Make Various Patterns, Including Vertical Bar Patterns, Horizontal Bar Patterns, Circle Patterns, 100% White Patterns, Check Patterns, Horizontal Bar Patterns, Vertical Bar Patterns, Color Bar Patterns, Red Color Patterns, Green Color Patterns, Blue Color Patterns,Yellow Color Patterns, Magenta Color Patterns, And Cyan Color Patterns. Learning Materials To Be Included: Theory, Procedure, Reference Results, Etc.] , Demonstration Kit Of Colour Led Tv Trainer [Display Type: Led; Hd Screen Size: 24 Inch (50Cm) Or More; Display Resolution: 1600 X 900 Pixels Or More; Video Interface: Video Input/ Vga, Hdmi And Or Dvi Input; Audio Output Power: 8W X 2; Receiving System: Pal Bg/I/Dk And Ntsc; Channel Coverage: Vhf-2-12, Uhf21-69; Catv (X~Z+2, S11s41) Mains Supply: 110-260V Ac ± 10%, 50/60Hz; Power Consumption: 35W] , Demonstration Kit Of Dth Trainer Kit [Colour Tft Lcd: 5.7” Tft Lcd; Rf Input: 950 - 2150 Mhz; Rf Output: 470 Mhz Two 862Mhz; Video Output: Pal/Ntsc; Uplink Satellite: Insat 4B; Test Points: 34 Nos.; Included Accessories: Mains Cord, Power Supply, Remote, Dish Antenna With Accessories, Lnb] , Demonstration Kit Of Photocopier [Interface Hi-Speed Usb 2.0 Copy Speed Simplex To Simplex Up To 20 Ppm In A4 (21 Ppm In Letter) Scan Method Color Cis Compatibility Twain, Wia Fault-Creating Facilities For Crum, Thermistor, Stepper Motor, Pickup Clutch, Feed Sensor, Width Sensor, Scanner Stepper Motor, Scanner Sensor, And Printer Door. Various Fault Switch With Test Points Provided On-Board.] , Demonstration Kit Of Fully Automatic Washing Machine Trainer Kit [Semi/Fully Automatic Washing Machine Mechanical Controls 30 Minutes Timer, Wash/Spin Control Atleast 6 Liter Capacity Machine Fault Switches For Wash Motor, Spin Motor, Lid Opening, Buzzer Etc All Faults Are Mounted On Pcb With Enclosure] , Demonstration Kit Of Microwave Oven Trainer Kit [Type: Solo; Capacity: >15 Ltr; Power Consumption: 600 Watt Or More: Child Lock And Alarm, Various Test Points] , Demonstration Kit Of Refrigerator [Industry Standard Specification To Perform Relevant Experiments. ] , Demonstration Kit Of Air Conditioner. [Industry Standard Specification To Perform Relevant Experiments. ] , Tdmpulse Code Modulation Trainer Kit [Crystal Frequency: 12/16 Mhz On Board Generators, 1. Adjustable Amplitude Sine Generator Of 500Hz & I Khz (Synchronised) 2. Variable Amplitude Dc Level (2 Nos.) Input Channels: Two Multiplexing: Time Division Multiplexing Modulation: Pulse Code Modulation Sync Signals: Pseudo Random Sync. Code Modulation Error Check Code: Off, Odd, Even, Hamming Operating Modes: Fast 240 Khz Channel (Approx) And Slow I Khz Channel (Approx) Pc - Pc Communication: 2 Channel Via Rs 232 Baud Rate: Selectable From 300 To 2400 Fault Switches : 8 Nos. Through 8 Way Dip Switch For Troubleshooting At Different Blocks Should Include Various Test Points] , Tdm Pulse Code Demodulation Trainer Kit [2 Channel Time Division Multiplexed Pulse Code Modulation Receiver. Fast (240 Khz/Channel Approx) And Slow (1Hz. /Channel Approx.) Mode Of Operation Pseudo Random Sync. Code Generator For Frame Synchronization. Receiver Clock Generation Using Pll. Error Detection Of None, Even, Odd, Hamming. Error Correction Using The Hamming Code Technique None, Even, Odd, Hamming Parity Selections Two Nos. Of 4Th Order Butterworth Low Pass Filter With Cut Off Frequency Of 3.4 Khz. Four Switched Faults For Fault Selection Block Description Screen Printed On Glassy Epoxy Pcb] , Fdm Transmitter / Receiver Kit [Two Variable Modulating (Sinusoidal) Input Channels With Provision Of Voice Inputs Two Dsbsc Modulators For Frequency Band Translation Of Two Test Signals Two Carrier Generators Two Sets Of Audio Input Amplifier One Adder/Transmission Amplifier Two Demodulators Two Low Pass Filters For Smooth Output] , Ask / Psk / Fsk Modulation And Demodulation Kit [The Kit Should Have An Integrated Ask / Psk / Fsk Modulation And Demodulation. Various Functional Block Diagrams Are Provided On-Board For Teaching/Training. Test Points To Visualize The Signals On Oscilloscopes] , Microwave Test Bench (Klystronbased) [Complete Klystron-Based Test Bench Study Of The Characteristics Of The Klystron Tube And To Determine Its Tuning Range, To Determine The Frequency & Wavelength In A Rectangular Waveguide Working On Te 10 Mode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , Microwave Test Bench (Gunn Based) [To Study The V-I Characteristics Of Gunn Diode, To Study The Voice Communication By Using Microwave Test Bench, To Study The Following Characteristics Of Gunn Diode, It Should Also Be A Ble To Study Characteristics Of The Directional Coupler, Attenuator And Isolator.] , 24 Awg Tinned Single Strand Jumper Wire Spool Blue Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Green Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Red Colour [90 Meter Spool] , 24 Awg Tinned Single Strand Jumper Wire Spool Black Colour [90 Meter Spool] , Flexible Electric Wire [2 Core, Twisted Flexible, Red And Black, 0.5 Sq Mm Copper Core, 50M Length] , Soldering Wire [Flux Core, Coil Type (Wire Of 100Gm )] , Inductor 1 Mh [8X10 Mm Radial Leaded Power] , Inductor 10 Mh [8X10 Mm Radial Leaded Power] , Led Red, Green, Blue, White Colour. Fifty Numbers Of Each Colour Led. [0.5W, Through Hole Type] , Ic 7400 [Ttl Ic-Quad 2-Input Nand Gate] , Ic 7402 [Ttl Ic-Quad 2-Input Nor Gate] , Ic 7404 [Ttl Ic-Hex Inverter Gate] , Ic 7408 [Ttl Ic-Quad 2-Input And Gate] , Ic 7432 [Ttl Ic-Quad 2-Input Or Gate] , Ic 7486 [Ttl Ic-Quad 2-Input Xor Gate] , Ic 7474 [Ttl Ic-Dual D Positive Edge Triggered Flip-Flop, Asynchronous Preset And Clear] , Ic 7476 [Ttl Ic-Dual J-K Flip-Flop, Asynchronous Preset And Clear] , Ic 7490 [Ttl Ic-Decade Counter (Separate Divide-By-2 And Divide-By-5 Sections)] , Ic 7495 [Ttl Ic-4-Bit Shift Register, Parallel In, Parallel Out, Serial Input] , Ic 74200 [Ttl Ic-256-Bit Ram (256X1)] , Ic 74147 [Ttl Ic Encoder] , Ic 74138 [Ttl Ic 3 To 8 Line Decoder] , Ic74151 [Ttl Ic Multiplexer] , Ic74138 [Ttl Ic Demultiplexer] , Ic 74169 [Ttl Ic Up-Down Counter] , Ic 74180 [Ttl Ic Parity Checker/Generator] , Ic 74Ls83 [Ttl Full Adder With Carry Ic] , Ic 74330 [Ttl Ic-Pla (12 Inputs, 50 Terms, 6 Outputs)] , Ic 4077 [Cmos Ic Xnor Gate] , Ic 4001 [Cmos Ic Nor Gate] , Ic 4011 [Cmos Ic Nand Gate] , Ic 4070 [Cmos Ic Exor Gate] , Ic 4071 [Cmos Ic Or Gate] , Ic 4077 [Cmos Ic Ex-Nor Gate] , Ic 4081 [Cmos Ic And Gate] , Ic 4093 [Cmos Ic Nand Gate] , Ic74ls47 [Bcd To 7-Segment Decoder/Driver Ic (7447 Ic) Dip-16 Package] , Lts542 [7-Segment Display - Common Anode] , Lts543 [7-Segment Display - Common Cathode] , Ic Dac0808 [Dac0808 8-Bit Digital To Analog D/A Converter Ic Dip-16 Package] , Ic Adc0809 [Adc0809 8-Bit A/D Converter With 8-Channel Multiplexer Ic Dip-28 Package] , Ic723 [Voltage Regulator Ic Input Voltage Up To 40V Output Voltage Adjustable From 2 To 37V Positive Or Negative Supply Operation Series, Shunt, Switching Or Floating Operation Output Current To 150Ma Without External Pass Transistor Adjustable Current Limiting] , Icl8038 [Function Generator Ic Wide Frequency Range - 0.001Hz To 300Khz Variable Duty Cycle - 2% To 98% High Level Outputs - Ttl To 28V Simultaneous Sine, Square, And Triangle Wave Outputs] , Ad633 [Analog Multiplier Ic 4-Quadrant Multiplication Low Cost, 8-Lead Soic And Pdip Packages Complete—No External Components Required Laser-Trimmed Accuracy And Stability Total Error Within 2% Of Full Scale Differential High Impedance X And Y Inputs High Impedance Unity-Gain Summing Input Laser-Trimmed 10 V Scaling Reference] , Lm566 [Vco Ic Wide Supply Voltage Range: 10V To 24V Very Linear Modulation Characteristics High Temperature Stability Excellent Supply Voltage Rejection 10 To 1 Frequency Range With Fixed Capacitor Frequency Programmable By Means Of Current, Voltage, Resistor Or Capacitor] , Ic Ne555 [Ne555 Timer Ic Dip-8 Package, Pack(Set) Of 30 Ics] , Ic 741 Op-Amp (Dip) [741 Ic - Dip Package - General Purpose Op-Amp Ic, Pack(Set) Of 50 Op-Amps] , Transistor 2N3904 [Pack (Set) Of 20 Transistors] , Transistor Bc107b [Pack (Set) Of 20 Transistors] , Diode 1N4007 [Pack (Set) Of 50 Diodes] , Fet- Bfw10 [Pack (Set) Of 50 Field Effect Transistors] , Zener Diode 5.6V, 1W [Pack (Set) Of 20 Zener Diodes] , Potentiometer 1 K?, 10 K?,100 K? Power Rating: 1W [20 Nos Of Each Value] , Wire Stripping Pliers, 6 Inch Long [Stainless Steel, Rust Resistant.] , Long Nose Mini-Pliers [Stainless Steel, Rust Resistant.] , Resistor 33O, 56O, 68O, 82O, 100O, 120O, 200O, 220O, 270O, 330O, 390O, 470O, 680O, 1K?,1.5K?. Maximium Power Rating 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Resistor 2.2K?, 2.7K?, 3K?, 4.7K?, 5.6K?, 6.8K?, 8.2K?, 10K?, 20K?, 36K?, 56K?, 68K?, 100K?, 470K?, 1M?, 2M? Maximium Power Rating: 1/4W [Pack(Set) Of 50 Nos Of Each Resistor Value] , Disk Ceramic Capacitor Of Values 220 Pf, 0.01 ?F, 0.024?F, 0.1?F, 0.24?F [Pack(Set) 25 Nos Of Capacitors For Each Valueh] , Disk Ceramic Capacitor Of Values 10?F(63V), 100?F, 220?F, 470?F(50V) [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Polypropylene Capacitor Of Values 0.001 ?F,0.01 ?F, 0.1 ?F, 0.22 ?F [Pack(Set) Of 25 Nos Of Capacitors For Each Value] , Tantalum Capacitor 10 ?F (25 V) [Pack(Set) Of 25 Capacitors] , Incandescent Bulb, 40W, 100W, 200 W [With Tungstenfilament And B22 Connector]
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
West Bengal View Result →
10.
Public Administrative Department #10894424 Price Bid
Tender for Ashok Leyland , Air Cleaner Assembly , Air Compressor , Br. Hose Assy , Brake Hose , Bundy Pipe Sub Assy , Compressor Delivery Pipe , Connecting Rod Assy , Crank Shaft , Cylinder Block , Cylinderhead , Drier And Distributor Valve , Gear Air Compressor Drive (Alt - F1661111) , Hose Assy , Kit-Air Intake System Comp , Low Pressure Indicator Switch , Major Repair Kit , Piston Assy- Std , Piston Repair Kit , Pre-Cleaner (Metal) , Primary Filter , Reed Valve Assy , Secondary Filter , Clutch Back Plate Kit , Clutch Bush Pin Kit , Clutch Disc Facing , Clutch Operating Lever , Clutch Plate Lever , Clutch Repair Kit , Clutch Rocking Shaft , Clutch S/C Major Kit , Clutch Withdrawl Bearing , Clutch Withdrawl Sleeve , Drag Link Assembly , Driving Plate , Lever On Shaft-Outer , Lipe Ceramic Clutch Disc (Alt - B1307001) , Rdc Clutch Cover Sub Assy. , Rdc Spring Kit , Slave Cylinder , 550Mm Ring Fan And Fan Clutch , Cac Inlet Pipe Hose - Engine Side , Cac Outlet Pipe , Cac-Inlet Hose , Cyilicon Hose , Hose - Radiator Inlet Radiator Side , L-Hose , L-Hose - Radiator Piping , Pipe -Turbo Outlet To Cac Inlet , Poly V. Pulley , Radiator Assy , Radiator Inlet Pipe , Ring Fan 550Mm Dia 7 Blade , Side Stay - Radiator Moungting , Tank Assy-Rad.Supp Ly , Turbo Outlet Pipe -Cac , Water Pump , Adjuster Ring , Carrier Mounting Fasterners Kit , Diff Brg , Diff Case & Nest Assy , Diff Spider Kit , Drive Gear & Pinion , Inner Bearing , Oil Seal & Pinion Nut Kit , Oil Seal Assy.-Flange , Outer Bearing , Pilot Bearing , Pinion Cage Assy , Pinion Cage Hardware Kit , Shim Kit-Pinion , Spacer Kit-Drive Pinion , Thrust Screw & Jam Nut Kit , Thrust Washer Kit , 4 Chamber Tail Lamp Rh , 55A Alternator (Lucas) Alt To X7489100 , Armature , Armature Assembly , Battery Cable - Battery +Ve To Isolator Sw , Battery Cable - Battery -Ve To Chasis , Battery Inter Connector , Battery Positive Cable , Bearing Bush Assembling Kit , Bearing Bush Assembling Kit , Brush Assembling Kit , Brush Gear Assembly , Brush Holder , Buzzer , Ce Bracket & Bush Assy. , Commutator End Shield , De Bearing Assembling Kit , Drive Assembly , Excitation Winding , Fasteners Assembling Kit , Field Coil With Thermal Cutout , Fog Lamp Assy , Head Lamp Assy , Horn Assembly , Ignition strengthening Lock , Intermediate Bearing , Isolator Switch Assy , Lead Assembly , Overrunning-Clutch , Plunger Assembly , Pulley , Rear Work Lamp , Rectifier Assembly , Relay Assembly , Rotor Assembly , Sealing Assembling Kit , Solenoid Switch , Solenoid Switch Assembly , Sre Ball Bearing , Starter Motor-Ltvs-24V-Pre-Engaged With , Stator Winding Assembly , Tail Lamp Assy Lh , Turn Signal Indicator , Wiper Arm And Blade Assembly - Driver Side , Wiper Kit Assembly , Wiping System (Kit) , Wiring Harness For Ve Cluster , Adaptor , Oil Fil , Adaptor Bracket , Air Intake Pipe , Ball Bearing, Alt - X0206110 , Bolt Con-Rod , Bolt, Bearing Cap , Breather Hose With Inner Spring , Bushing Con Rod , Camshaft , Camshaft Bush Kit , Composite Valve Kit , Composite Valve Seat Kit , Con Rod Bearing Kit , Con Rod Bearing Kit , Connecting Rod , Crank Shaft Main Bearing Set , Crankshaft, Microalloyed , Damper, , Decarbonising Gasket Kit , Dipstick And Guide , Element Oil Cooler Sub Assy. , 6 Plates , Engine Cylinder Head Assy. , Engine Mounting Bracket , Engine Mounting Bracket , Exhaust Valve , Fly Wheel Bearing Ball , Fly Wheel Ring Gear , Front End Plate Gasket , Gasket Cylinder Head , Gasket Over Hauling Kit- Complete , Gear Crankshaft , Gear, Camshaft Alt To F1661211 , Idler Gear , Intake Manifold , Intake Valve , Liner Cylinder S/S , Manifold, Exhaust , Oil Cooler Gasket , Oil Pump , Oil Strainer Sub Assy. , Piston Ring Set- , Piston Set(With Pin) , Piston,Pin And Ring Set , Plate, Front End Timing Back Plate , Rocker Arm , Rocker Shaft , S/A First Pipe Silencer , Second Pipe Sub Assembly , Series C/S Rear End Plate Oil Seal , Spacer , Special Flanged Bolt , Tail Pipe Assy , Thermostat , Thrust Washer Set - Std , Valve Guide Kit , Valve Intake Seat , Valve Spring Inner , Valve-Exhaust Seat , Brake Drum , Cover Plate For King Pin , Distance Piece- , Front Axle Taper Roller Bearing , Front Hub , Hub Cap , Joint Cover Plate , M20 Bolt For Fa 99 Track Rod Lever Mountg. , Oil Seal - Hub , Ring For Oil Seal , Steering Lever , Track Rod Assembly , Track Rod Lever , 200L Tank Comp Sub Assy , Camshaft , Control Rod , Delivery - Valve Assembly , Delivery - Valve Holder , Flywheel Coupling , Fuel Filter Cum Water Separator , Fuel Hose - Suction Sub Assy , Fuel Sensor Unit , Gear Injection Pump Drive , Hose Assembly-Filter To Fip , Hose Assy - Feed Pump To Fuelfilter Cum W/S , Injector Assy , Overflow Valve , Roller Tappet , Shut Off Solenoid 24V , Strainer Assy , Tapered-Roller Bearing , Timer For Shut Off Solenoid (24V) , Circlip Kit , Const.Mesh Gear On Lay Shaft , Cover-Reverse Idler (Sheet Metal) , Fixed Dog Clutch Reverse , Gasket , Gear Change Finger , Gear On Main Shaft , Input Shaft , Joint , Layshaft(Counter Shaft) , Main Shaft , Needle Roller Bearing , O/D Gear On Layshaft , O/D Gear On Mainshaft , Oil Seal , Rev. Gear On Ms , Reverse Idler Gear , Reverse Idler Pin , Reverse Selector Fork , Roller Bearing ( Alt. Part No. F0259210 ) , Roller Bearing Rear ( Alt .F0259310 ) , Selector Fork , Selector Housing , Selector Shaft , Sliding Pad(Selector Pad) , Sliding Sleeve , Spigot Bearing , Synchro Cone , Synchro Pack , Taper Roller Bearing , Zf Gear Box Gasket Kit , Zf Seal Kit , Bracket - Shock Absorber , Centre Bolt & Nut Kit , Front Shock Absorber , Front Spring , Rear Spring , Shackle Pin , Shock Absorber Mounting , Spring Eye Bush , Spring Shackle , Spring Shackle Sub Assy , U Bolt , Assembly Proximity Mirror , Door Glass , Door Lock Assembly Kit , Filter Element , Fuel Gauge , Housing Cover Assy. R.H. , Oil Tank Assy. , Rpm Meter With Hour Meter , S/A Of Acceleration Bracket And Shaft , Sealing Kit , Sector Shaft Assy. , Shaft And Lever Assembly - Throt , Small Component Kit , Speedo Movement Ratio , Temperature Gauge , Weatherstrip - Door Glass Channel , Windscreen Glass , Windscreen Rubber Beading , Cb Kit Assembly , Companion Flange , Flange Yoke For Drive Shaft , Mid Ship Tube Shaft , Msts Nut , Propeller Shaft Kit , Slip Yoke Assembly , Tube Shaft , Tube Yoke , Uj Kit , Anchor Pin-Brake Shoe , Axle Shaft Long , Axle Shaft -Short , Bracket Mounting Fasteners Kit Comp , Brake Chamber Repair Kit , Brake Drum , Brake Lining Front , Brake Lining Rear , Brake Minor Repair Kit- , Brake Pedal , Brake Spring Kit , Bushing - Cam , Camshaft , Camshaft Repair Kit , Camshaft Washers Kit Comp , Clutch Pedal , Fulcrum Pin , Gasket , Gasket-Bracket & Spider , Hand Brake Valve , Hub Bearing , Kit Lining Set-Std Comp , M.C.Kit , Major Repair Kit- (Rear Brake) , Mc Assembly , Minor Repair Kit , Mtg Bracketbattery Carrier , Oil Seal , Oil Seal Ring-Outer , Rear Hub , Repair Kit For Dual Brake Valve , Repair Kit For Rear Brake Chamber , Return Spring-Brake Shoe , Roller , Front Tyre , Rear Tyre , S/A Of Pedal Bracket , Stud For Axle Shaft , Wheel Bolt , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Exhaust Elbow , Oil Drain Pipe, Flexible - Turbo Charger , Turbo Charger , Turbo Charger With Adaptor Sub Assy , Wheels & Tyres , Bearing , Bearing Lower Teeeth 36 , Dipcase Bearing , Front Hub Bearing , King Pin Bearing T-149 , Main Shaft Bearing , Needle Bearing , Pinion Bearing , Planet Gear Bearing , Rear Wheel Bearing , Reversal Bearing , Transmission Bearing , Accelerator Cable Spring , Black Pad Nylon , Blue Pad Nylon , Boom Clip , Boom Shim , Boom Stablizer Spring , Bucket Ball Joint , Bucket Pin Washer , Bucket Shim , Cabin Mounting , Circlip , Clamp Bolt With Nut , Collapsible Tube , Dipper Shim , Engine Mounting , Externat Circlip , Grease Nipple , Green Pad Nylon , Hub Cover Plate , Hub Plug , Hydra Clamp Nut , Hydraulic Valve Protection Pad , King Pin Shim , King Post Bolt , Kpc Shim , Lower Cab Mounting , Lower Wear Pad Plastic , Oil Drain Plug , Pinion Nut , Protection Pin , Rear Axle Nut , Rear Hub Stud With Nut , Rear Wheel Nut , Red Pad Nylon , Rubber Mounting , Slew Ram Bolt , Stabilizer Wear Pad Nylon Type , Steel Washer , Strap , Throttle Overload Spring , Throttle Pedal Spring , Thrust Pad , Thrust Washer , Turret Seat Thick , Turret Washer Thin , Upper Cab Mounting , Upper Wear Pad Small Plastic , Wear Pad , Yellow Pad , Brake Booster , Brake Disc , Brake Friction Plate , Brake Master Cylinder , Brake Pedal Spring , Brake Piston , Brake Plate , Driven Plate Kit , Friction Plate , Boom Bush , Bucket Pin Bush , Bucket Rod Bush , Cut Bush , Cylinder Bushing Mount Holder , Dipper Rod Bush , Front Axle Bush , King Pin Bush , King Post Bush , Linear Bearing , Loader Arm Bush , Slew Rod Bush , Steel Bush , Steering Axle Bush , Steering Bush , Tie Rod Bush , Tipping Link Bush , Twin Cylinder Bush , Door Handle , Door Latch Assy Rh , Door Lock , Engine Side Panel Rh , Fender , Grill , Leg Rain Cap , Side Window Handle , Steering Wheel , Steering Wheel Knob , Cable , Cable Lever , Gas Strut , Throttle Cable , Throttle Cable With Handle , Alternator , Coil 12V , Diffuser Direction , Front Lamp Assy. , Fuel Level Indicator , Glow Plug , Ignition Switch , Rear Lamp , Rear Lamp , Rear Lamp Assy. , Rear Light , Rear Light Len , Rear Worklight , Refrigerant Fluid Temperature , Solenoid , Solenoid Assy , Solenoid Valve , Starter Motor , Switch Reverse - Forward , Tachometer Hour Meter , Tachometer Revolution Meter , Temperatur Guage , Temperature Sensor , Thermostat Housing , Belt Tensioner , Connecting Rod , Connecting Rod Bush , Crank Shaft Pulley , Crank Shaft Pulley , Diesel Fuel Cap , Dipstick , Elbow Hose , Electrical Valve Gasket , Engine Cooling Fan 21 , Engine Oil Dip Stick , Engine Piston , Engine Valve , Exhaust Elbow , Filter Glaas Bowl , Fly Wheel Ring Gear , Fuel Leak Off Assy. , Fuel Pipe , Fuel Pump , Fuel Sediment Filter Assy , Fuel Tank Cap With Keys (Small) , Gasket Set , High Pressure Pipe 3&4 , Hydraulic Level Guage , Hydraulic Tank Sight Guage , Oil Cooler Gasket , Oil Filler Cap , Oil Pump , Pipe Fuel Filter To Fuel Injection Pump , Preleaner Assy , Preleaner Glass , Pressure Cap , Push Rod , Radiator Hose Bottom , Rocker Cover Gasket , Top Radiator Hose , Valve Collet , Valve Seat , Water Hose Bottom , Water Pump , Watern Hose Bottom , Yellow Cap , Air Filter , Air Filter Assy , Engine Oil Filter , Fluid Reservoir , Fuel Filter , Fuel Filter Assy. , Fuel Filter , Hydraulic Filter , Hydraulic Filter Long Type , Hydraulic Filter , Hydraulic Tank Strainer , Reservoir , Suction Strainer , Transmission Filter , Auxillary Relief Valve , Hyd. Pump Centre Body , Hyd. Pump Drive Gear Shaft Big , Hyd. Pump Flange With Bushes , Hyd. Pump Gear Set , Hyd. Pump Plate Bush , Hyd. Pump Seal Kit , Hyd. Pump Wear Plate , Hydra Clamp Housing , Hydraulic Pump , Hydraulic Pump Key , Hydraulic Pump , Main Relief Valve , Pilot Unloader Valve , Single Pump With Gear 36Cc , Spool Valve , Vaccum Pump With Gear , Centre Pin , Pivot Pin , Pivot Pin Boom Knose , Axle Oil Seal , Brake Piston Ring , Brake Piston Seal , Clutch Seal , Cylinder Seal Kit , Distributor Slider Seal , Dust Seal , Front Axle Crossover Seal , Front Axle Ring , Front Engine Seal , Fuel Injection Seal , Fuel Settler Ring , Gearbox Seal , Hub Oil Seal , Hub Seal , Hydra Clamp Seal , Hydraulic Tank Gasket , Hydraulic Valve Seal , King Pin Seal , O Ring , Oil Seal , Pin Seal , Pinion Cover Slew Gasket , Piston Seal Kit , Rear Engine Seal , Seal Ring , Slew Swing Cylinder Seal Kit , Steering Cyllinder Seal Kit , Transmission Filter Gasket , Transmission Piston Inner , Transmission Pump Ring , Transmission Pump Seal , Transmission Shaft Teflon Ring , Valve Stem Seal , Water Inlet Gasket , Wiper Seal , Orbital Assy. , Pressure Relief Valve Steering , Rack End , Steering Coupling , Tie Rod Assy. , Centre Tooth , Side Cutter , Adaptor Block Assy. , Annulus Carrier , Annulus Ring , Brake Gear , C.W. Stud , Carriage , Clutch Housing With Gear , Clutch Housing With Gear , Cross Universal Joint , Crown Wheel & Pinion Assy. , Crown Wheel & Pinion Set , Differential Case Assy. , Differential Cross , Differential Gear Set O/M , Differential Washer Set , Double Joint Yoke , Drive Shafts , Foot Side Shift Stablizer , Front Axle Crossover Trunion , Front Drive Shaft , Front Hub , Gear Charging Pump , Gear Lever Rubber Boot , Gear Lever Rubber Cap , Gear Shift Lever Tension Spring , Gear Shift Lever , Hydra Clamp Housing O/M , King Post , Kingpost Carriage , Layshaft , Pinion Drive Gear , Pinion Gear , Pinion Shaft , Planetary Gear , Power Steering Pump , Pump Drive Shaft , Pump Shaft Yoke , Rear Axle Drive Shaft , Rear Hub , Steering Pump , Stub Axle Carrier , Sun Gear , Synchroniser Sleeve , Synchronizer Assy. , Terrot Housing O/M , Tipping Lever , Tipping Link , Tippining Liver , Transmission Piston , Trunnion , Yoke Coupling , Yoke Flange , Yoke Flange , Wheels & Tyres , Mahindra Bolero , Gear Fork , Gear Pinion , Air Cleaner Hose Pipe , Air Pressure Horn , Alternator Stator , Alternator Bearing (Roller Type) , Alternator Bushing , Alternator Carbon , Alternator Cashing , Alternator Commulator , Alternator Cutout , Alternator Dunamo Assly , Alternator Rectifire (Positive/Neg.) , Alternator Rotter , Axle Bearing , Back Gear Pinion , Back Light Assly. , Battrey Terminal , Benet Hook With Clip , Benet Monogram , Benet Tana Rod , Black Tap (Big) , Body Mounting , Brake Fexiable Pipe , Brake Lining , Bumper End , Bumper Gutka , Cam Shaft Bush/Bearing , Car Fan , Carbon Holder , Carburator Assly. , Carburator Butter Fly , Carburator Repair Kit (Major) , Chamber Bolt , Chamber Gasket , Clutch Adjusting Rod , Clutch Cable Assly , Clutch Plate Assly. (Plain/W/Facing) , Clutch Release Bearing Hub , Clutch Spring , Condenser , Connecting Bearing , Connector , Counter Gear Assly , Counter Gear Pinion , Counter Shaft Pin , Counter Shaft Roller , Counter Shaft Thrust Washer , Crank Shaft Bearing , Cross Holder , Cross Member , Cross Member , Cross Member Front Assly , Cross Member Rear Assly , Crown & Tail Pinion Assly. , Diesel Filter Assly , Diesel Flexiable Pipe , Differential Crown Pinion Shaft , Differential Gasket , Differential Oil Seal , Digi Rubber , Distributor Assembly , Distributor Cap , Distributor Plate Assly , Door Glass Handle , Door Glass Machine , Door Glass Rubber , Door Glass Channel , Door Half Lock , Door Handle/Lock/Kabja , Door Lock Assambly , Door Regulator Machine , Driving Glass , Dynamo Alternator Pully , Engine Cross Member , Engine Head Bolt , Engine Head Gasket (Full Set) , Engine Head Gasket (Single Pice) , Engine Head Stud F/T , Engine Main Bearing , Engine Mounting , Engine Valve (Inlet & Exhust) , Fan Assly , Fan Belt , Feed Pump Assly , Flang Stand (Double/Single) , Flasher , Fly Wheel Bearing , Fog Light Assly , Fog Light Bulb , Foot Board , Front Shockobsorbar , Front Spring , Front Spring Hanger , Front Spring Main Leaf , Front Spring Shackle Bush , Front Spring Shackle Pin , Fuel Meter , Gear Box Gasket , Gear Box Mounting , Gear Box Oil Seal , Gear Box Seal Kit , Gear Box Thrust Washer , Gear Lever Fork , Grill Assly , H T Wire , Head Light Assly , Head Light Bulb , Head Light Bulb , Head Light Holder , Head Light Seal Beam , Head Light Switch , Heater Plug , Heater Switch , Hood Light Assly , Ignation Switch , Gear Pinion , King Pin Bearing , King Pin , King Pin Oil Seal , L T Wire , Looking Glass (Rear View Mirror) , Main Bearing Coller Oil Seal , Main Shaft Assly , Main Shaft Bearing , Main Shaft Locknut/Oil Seal/Roller/Washer , Manifold Gasket , Master Cylender Assly , Mobile Filter Flexible Pipe , Mounting Buffer , Mudgard Bolt (F/T) , Oil Filter Element , Oil Pressure Switch , Oil Pump Assly , Parking Light Glass , Petrol Tank Assly , Petrol Tank Cap With Key , Petrol Tank Caps Rubber , Petrol Tank Hose Pipe , Petrol Tank Pipe (Steel) , Pisto Ring , Pisto Sleeve , Pisto With Pin , Plastic Tap , Plug Socket , Pressure Plate Assly , Propular Shaft Bolt , Propular Shaft Centre Bearing , Propular Shaft Teeth , Propular Shaft U Bolt , Propular Shaft Youk , Push Pull Switch , Radiator Assly. , Radiator Cap , Radiator Hose Pipe (Uper,Lower) , Radiator Hose Pipe Clamp , Rear Spring Clamp , Rear Spring Leaf , Rear Spring Centre Bolt , Rear Spring Clamp Bolt , Rear Spring Main Leaf , Rear Spring Mounting , Rear Spring Mounting Bolt , Rear Spring Shackle Assly , Rear Spring Shackle Bush Steel , Rear Spring Shacklr Pin , Rear Spring U Bolt , Release Carbon , Rotter , Self Carbon , Self Bushing , Self Housing Plate (Bushing/Brg. Side) , Self Housing Armature 12 Volt , Self Housing Field Post , Self Housing Plate (Carbon Side) , Self Starter Assly , Self Starter Bandix Assly , Self Starter Bushing Cover , Self Starter Solenied Switch , Self Starter Switch , Servo Assly , Shim Washer , Shockobsorber Bolt , Shockobsorber (H/ Duty) , Side Light Assly , Side Light Bulb , Side Light Glass , Side Light Holder , Side Light Switch , Silencer Box (Muffler) , Silencer Clamp , Silencer Gasket ( O) Ring , Sparking Plug , Spedo Meter Cable Assly. , Spedo Meter , Spedo Meter Pinion , Spring Clamp , Spring Clamp Bolt , Spring Show Mounting , Spring U Bolt (Front) , Starting Pully , Steering Box Assly , Steering Collumn , Steering Demper Bush , Steering Rack Assly , Steering Sector Oil Seal , Steering Sector Shaft With Gear , Steering Bolt Joint (Tie-Rod) , Steering Bolt Joint Lock , Steering Combination Switch , Steering Control Rod , Steering Demper Bushing Kit , Steering Horn Bottom Switch , Steering Knockle Kit , Stop Light Switch , Sttring Lever Switch , Sttring Wheel , Sttring Wheel Bush , Sttring Wheel Cover , Suspension Bushing Kit(Major) , Sycronizer Lock Ring , Sycronizer Lock(Maghi Lock) , Sycronizer Spring , Sycronizer Assly , Syncronizer Brass Ring , Tail Pinion Bearing , Tank Float Unit , Tappet Cover Gas Ket , Tie Rod End Drive Set , Tie Rod Pipe , Timing Chain , Top Shaft Assly , Top Shaft Bearing , Top Shaft Oil Seal , Top Shaft Pinion , Top Shaft Roller , Vaccum Horn Pipe , Valve Lock , Valve Oil Seal , Water Pump Gasket , Water Pump Assly , Water Pump Bearing , Water Pump Pully , Wheel Bearing , Wheel Cap , Wheel Cylender Assly. , Wheel Cylender Boot , Wheel Cylender Brucket , Wheel Cylender Kit , Wheel Cylender Pipe , Wheel Cylender Piston , Wheel Drum , Wheel Hub Assly. , Wheel Oil Seal , Wheel Rim , Whel Axle Shaft /Axle Assly. , Wipper Arm & Blade , Wipper Machine Electronic Vaccum Type , Wipper Wheel Box , Wipper/Pennel Switch , Front Tyre , Rear Tyre , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Wheels & Tyres , Tata 407 , Ampere Meter , K.M (Speedo Meter) , K.M Cable , Oil Pressure Assembly , Temperature Meter , Bevel Pinion Set , C. Side Bearing Cap Bolt , Crown & Tail Pinion Assembly , Crown Case Bolt , Crown Side Adjustor , Crown Side Bearing , Diff. Cover Gasket , Diff. Gear Shaft , Differential Spider Cross , Driver Gear , Rear Axle , Spider Washer , Tail Pinion Bearing , Tail Pinion Adjs. Shim , Tail Pinion Coupling , Tail Pinion Nut , Tail Pinion Oil Seal , Bonnet Kapza , Bonnet Lock , Cabin Mounting , Clutch Fork Rod , Clutch Housing Gb. 30 , Clutch Housing Gb. 40 , D. Filter Catching Assembly , Dynamo Armature , Dynamo Bearing Big , Dynamo Bearing Small , Dynamo Carbon , Dynamo Field Coil , Dynamo Plate , Engine Mounting Bolt , Fly Weight Assembly , Handle , Head Bolt With Washer , Jack With Handle , M. Filter Catching Assembly , Oil Cooler Side Plate , Servo Repair Kit , F & R Shackle Bush , F & R Shackle Washer , F&R Shackle Pin , F&R U Bolt , Front & Rear C.Bolt , Front Aux. Leaf A&B , Front Eighth Leaf , Front Fifth Leaf , Front Fourth Leaf , Front Main Leaf , Front Second Leaf , Front Seventh Leaf , Front Sixth Leaf , Front Spring Assembly , Front Third Leaf , Rear Aux. Assembly , Rear Aux. Leaf F&R , Rear Eighth Leaf , Rear Fifth Leaf , Rear Fourth Leaf , Rear Main Leaf , Rear Ninth Leaf , Rear Second Leaf , Rear Seventh Leaf , Rear Sixth Leaf , Rear Third Leaf , A.C. Head , Air Cleaner Pipe , Air Cleaner Rubber , Brake Shoe Return Springs , Brake Shoe Rivits , Double Gear , F & R Hub Assembly , F & R Shock Absorber , F. Brake Shoe Tawa , F. Spindle Choak Nut , F. W.C Repair Kit , F. Wheel Bearing I , F. Wheel Bearing O , F. Wheel Brake Shoe , F. Wheel Cylinder Assembly , F. Wheel Oil Seal , Front Brake Drum , Front Spindle , Front Wheel Rim , Hub Wheel Bolt , King Pin Bearing , King Pin Bush , King Pin Set , King Pin Shim & Lock Kit , Nozzle Pipe Set , R.W.C. Bucket With Boot , Rear Wheel Brake Shoe , Shocker Bolt , Third Arm Bolt , Front Tyre , Rear Tyre , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Chillam , Chillam Oil , Counter Gear , Counter Washer Kit , First Gear , Fourth Gear , Gear Box Coupling , Gear Box Cover Kit , Gear Box Gasket , Gear Box Housing , Gear Box Mounting , Gear Box Oil Seal , Gear Box Top Cover , K.M Pinion , K.M Pinion Back Casing , Main Shaft Assembly , Main Shaft Bearing , Main Shaft Bearing special , Main Shaft Roller , Over Flow Valve , Second Gear , Servo Assembly , Synchronizer Assembly , Synchronizer Brass Ring , Synchronizer Lock Kit , Synchronizer Outer , Third Gear , Top Shaft Pilot Bearing , Top Shaft Ruler Bearing , Top Shaft Assembly , Top Shaft Bearing Outer , Top Shaft Check Nut, , Top Shaft Roller , A.C Cam Cutting , A.C. Block Boaring , A.C. Sleeve Fitting , Block Boaring , Block Bush Fitting , Block Facing , Block Line Boaring , Brake Drum Polishing , Cam Bush Fitting , Cam Polishing , Connecting Boaring , Connecting Bush Fitting , Crank Cutting , Fly Weight Tuning , Fuel Pump & Nozzle Overhauling With Materials , Head Facing , King Pin Overhauling , Oil Seal Brass Welding & Matching , Sleeve Fitting , Valve Guide Fitting , Valve Seat Fitting , Back Light Assembly , Back Light Glass , Brake Flexible Pipe , Brake Sdjuster , Brake Switch , completion Switch , Double Horn , Dynamo Cut Out , F.S Ind. Light Assembly , Flasher Unit , Fog Light Assembly , Fuse Box , H.L. Assembly , Head Light Holder , Headlight Bulb , Horn Cut Out , L.T. Wire - Roll , M.C Repair Kit , M.C.Assembly , Parking Light Bulb , Push Button Switch , Side Mirror , Starting Switch , Wiper Arm , Wiper Blade , Wiper Motor Assembly , Alternator Armature , Alternator Assembly. , Alternator Cut Out , Alternator Roc. Assembly , C, Bearing Without Oil Seal , C. Bearing Bracket , C. Bearing Rubber , Dynamo Rivits , Dynamo Pully , P. Shaft Cross Holder , P. Shaft Flange , P.Shaft Assembly Rear , P.Shaft Half Yoke , P.Shaft Yoke & Teeth , Propeller Shaft Assembly , Propellor Shaft Bolt , U.J. Cross , Self Armature , Self Assembly , Self Bendix , Self Bush , Self Carbon , Self Carbon Plate , Self Casing , Self Clutch Assembly , Self Field Coil , Self Flanger Bolt , Self Housing , Self Pinion , Self Point , Self Solenoid Switch , Steering Bearing , Steering Boot , Steering Box Assembly , Steering Bush , Steering Column Assembly , Steering Cone , Steering Coupling , Steering Cross Assembly , Steering Drug Link Assembly , Steering Gasket , Steering Sector Adj. , Steering Sector Assembly , Steering Sector Oil Seal , Steering Shaft With Bush , Tie Rod Controller Kit , Tie Rod End , Tie Rod End Clamp , A.C. Pump Assembly , A.S. Pump Repair Kit , Oil Pump Assembly , Oil Pump Gear , Oil Pump Repair Kit , Oil Releaf Valve , Radiator Assembly , Water Pump Assembly , Water Pump Bearing , Water Pump Gasket , Water Pump Impeller , Water Pump Repair Kit , Water Pump Seal Kit , Water Pump Shaft , A.C . Ring , A.C Bearing , A.C. Linner , A.C.Kit , A.C.Piston , Air Tank Assembly , Cam Shaft Bush , Champer Gasket , Clutch Plate Gb .30 , Clutch Plate Gb.40 , Clutch Release Bearing , Clutch Repair Kit , Connecting Bearing , Connecting Rod Assembly , Connecting Rod Bolt , Connecting Rod Bush , Crank Shaft P. Assembly , Crank Shaft P. Bearing , Diesel Filter , Diesel Flexible Pipe , Engine Gasket Unit , Engine Mounting , Engine Mounting Rear , Engine Valve (Exhaust) , Engine Valve (Inlot) , Fan Belt , Fly Wheel Bearing , Fly Wheel Ring , Head Gasket , Main Bearing , Main Bearing Colur , Main Bearing Oil Seal , Main Bearing T.Washer , Mobile Filter , Mobile Flexible Pipe , Piston A , Piston Ring , Piston Sleeve , Pressure Plate . Gb. 30 , Pressure Plate. Gb. 40 , Radiator Hose Pipe , Rocker Arm Bush , Rocker Arm Shaft , Silencer Pipe Front , Silencer Gasket , Silencer Muffler , Silencer Pipe Rear , Tappit Cover Gasket , Third Gear Fork , Timing Cover Gasket , Timing Cover Oil Seal , Valve Guide , Wheels & Tyres , Tata Ace , Fitting Of Ac In The Car , Gas Filling , General Servicing Of Ac , Removal Of Ac From The Car , Bonnet Adjustment , Removing And Replacing Of Door Handle , Removing And Replacing Of Door Lock , Removing And Replacing Of Rear Back Light , Replacement Of Channel Set And Bidding Set , Replacement Of Door Bidding Set , Replacement Of Door Canned Set , Replacement Of Door Glass Each , Replacement Of Door Gola , Replacement Of Door Handle Set , Replacement Of Front And Rear Bumper , Replacement Of Front Wind Glass , Replacement Of Roof Upholstery , Replacing Door Hinges Pins Of Each Door , Replacing Door Window Regulator , Adjustment Of Brake Bleeding System , Adjustment Of Foot Brake Shoe , Bearing And Adjustment , Overhauling Of All The Wheel Cylinder , Overhauling Of Complete Brake Dsysterm , Overhauling Of Master Cylinder , Replacement Of Complete Break Linings , Replacement Of Break Drum Front , Replacement Of Break Drum Linings , Replacement Of Break Shoe And Blooding , Replacement Of Front Brake Linings , Replacement Of Front Break Drum , Replacement Of Hand Break Cable , Replacement Of Rear Brake Linings , Replacement Of Wheel Cylinder ( One Side ) , Adjustment Of Free Travel Of Clutch , Clutch Overhauling , Overhauling Of Clutch Plate Assembly , Replacement Of Clutch Adjusting Rods , Replacement Of Clutch And Brakes Pedal Shafts/Bushes , Replacement Of Clutch Plates , Dynamo , Dynamo Assembly Replacement , Fitting Of New Electric Bulb In Parallel , Fitting Of New Search Light , Fitting Of Speedometer Cale Assembly , Head Light Focusing , Oberhauling Of Self Starter , Overhauling Of Horn Ring , Overhauling Of Wiper Moter , Repairing Of Horn , Replacement Of Dynamo Fan , Replacement Of Dynamo Pulley , Replacement Of Horn Ring Starter Place Sleeve , Replacement Of Ignition Switch , Replacement/Check-Up Of Fuel Guage Dashboard , Replacemnt And Check-Up Of Wiper Blade , Replacemnt Of Armature , Replacemnt Of Complete Wiring , Replacemnt Of Dashboard Light Bulb , Replacemnt Of Fuel Guage Tank Unit , Replacemnt Of Head Bulb Each , Replacemnt Of Self Starter Switch , Replacemnt Of Side And Tail Light Bulb , Replacemnt Of Solenoid Switch , Replacemnt Of Voltage Regulator , Replacent Of Wiper Moter , Testing And Recharging Of Battery , Adjustment And Refitting Of Oil Pressure Relief , Adjustment Of Tappet , Change Of Flywheel Ring , Claening And Replacemt Of Spark Plug , Claening Of Carburator , Cleaning Of Distribute , Cleaning Of Distributer Cap , Cylinder Head Overhauling , Engine Timimg Tappet Adjustment, Distributer And G.R.Point, Spark Plugs Cleaning And Adjustment , Overhauling Of Fuel Pump , Overhauling Of Water Pump Assembly , Overhauling Of Water Pump Bearings , Overhouling Of Complete Engine , Refitting Of Connecting Rod Bearing , Refitting Of Oil Pump , Replacement Of Accelerator Wire , Replacement Of Timing Coverplace , Replacement Of Vaulve Guide , Replacemnt Of Fan Belt , Replacemnt Of New Timing Chain , Replacemnt Of Timimng Covers Packing , Replacemt Of Main Bearing , Rocher Shaft And Tappet Replacement , Exhaust , Realigning Exhaust Pipe Assembly , Replacement Of Exhaust Pipe Front , Replacement Of Muffler Assembly, Buffer Plate , Replacement Of New Muffler , Replacement Of Silencer Pipe ( Each ) , Replacement Of Tail Plate , Remove Cleand And Refitt Fuel Tank , Replace Fuel Tank Hose Pipe , Replace Petrol Flexible Pipe Each , Replace Petrol Tank Hard Board Cover , Overhauling Of Gear Box , Overhauling Of Gear Box Assembly , Replacement Of Front Oil Seal , Replacement Of Gear Box Foundation , Replacement Of Gear Lever , Replacement Of Gear Linkage Ball Joint , Replacement Of Side Dash Cover Packing And Seal , Complete Painting After Scrapping Old Paint , Complete Painting Color Change , Complete Painting Double Coat Without Dent , Complete Painting Single Coat Without Dent , Fitting Of New Propeller Shaft , Fitting Of New Propeller Shaft U Point , Overhauling Of Differential,Dismantlingof Rear Axle Fitting With New Charts , Refitting Of Rear Axle Assembly Including Bending And Adjusting Brakes , Replacement Of Back Plate Assembly From The Axle Casing Flange , Replacement Of Differential Packing , Replacement Of Hub Bearing , Replacement Of Hub Oil Seal , Replacement Of Pinion Oil Seal , Replacement Of Rear Axle Shaft , Replacement Of Rear Brake Drum , Adjustment Of Ball Joint , Adjustment Of Damper Pad , Adjustment Of Flang , Adjustment Of Pinion Bearing , Adjustment Of Pinion Thrust , Adjustment Of Tie Rod Ends , Adjustment Of Toe-In And Toe-Out , Overhauling Of Cpmplete Steering , Removal Of Refitting Of Steering Assembly , Replacement Of Ball Joint (Each) , Replacement Of Bottom Melt Of Steering Wheel , Replacement Of Bracket Column Sipport Asssembly , Replacement Of Gear Control Rod , Replacement Of Gear Control Rod Assembly , Replacement Of Gear Control Rod Support Pivot Pin Selector Lever New Making , Replacement Of Gear Pivot Breakings , Replacement Of Steering Column , Replacement Of Steering Wheel , Replacement Of Tie Rod Ends , Replacement Of Top Melt Of Steering Wheel , Setting Of Wheel Castor Chamber And Toe-In-Out , Overhauling Of Complete Suspension , Replacement Of Broken Leaf , Replacement Of Front Bush Suspension , Replacement Of Front Wheel Oil Seal , Replacement Of One Shoch Absorber , Replacement Of Rear Spring Assembly , Replacement Of Rear Spring Bushes , Replacement Of Rubber Bush Kit , Replacement Of Tie Bar Bush (One Side ) , Replacement Of Torsion Bar , Front Tyre , Rear Tyre , Dry Servicing And Lubrication , Engine Tuning , Greasing The Vehicle , Replacing Oil-Filter And Engine-Oil Change , Rubbing And Policing The Vehicle , Servicing And Lubrication, Replacing Oil-Filter Element , Washing , Wheels & Tyres , Tractor , Actuating Lug Assy. , Bracket , Dowel Pin , Fixed Gear , Fork Assy , Propeller Shaft Cover , Sliding Gear , Universal Joint Assy. , Canopy , Dry Air Cleaner Assy. , Filter Cartridge Dry Air Cleaner , Gasket Inlet Cover Assy. , Hose Clamp , Hose Clip , Pipe Inlet , Clutch Housing , Clutch Plate , Copper Washer , Inner Bush , Metalic Bush , Shaft Assy. , Single Cluth Assy. With Clutch Plate , Spring Dowel Sleeve , Control Valve Assy. , Kit Camshaft , Kit Position Lever , Kit Quadrant With Friction , Anti Freeze Coolant , Ctb Clamp , Hose Clip , Hose Pipe , No Loss Tank , Radiator Assy , Radiator Hose , Bushing Cam Shaft , Bushing Knock , Cap Set Bearing , Case Oil Seal , Crankcase Assy , Gasket Oil Seal Case , Gasket Plate Front , Main Bearing Set , Oil Filter , Pin Dowel , Plate Front , Plug Expanision , Rear Plate , Side Seal , Connecting Rod Assy , Crankshaft Gear , Crankshaft Nut , Flywheel Bolt , Piston , Plane Washer , Pulley Engine , Ring Gear Fly Wheel , Ring Sets Piston , Cap Sealing , Cap Valve Stem , Cylinder Head Assy , Gesket Cylinder Head , Guide Exhaust Valve , Hose Clamp , Hose Pipe , Jet Combustion , Plate Connector , Retainer Valve Stem , Seal Valve Stem , Seat Exhaust Valave , Seat Inlet Valve , Spring Valve , Spring Washer , Tappet , Thermostat Housing , Valve Exhaust , Valve Inlet , Valve Lock Spring , B.P. Shaft , Cage Carrier , Pedal Assy. , Sleeve , Battert Cut-Off Switch Mtg Plate , Battery , Beacon Lamp , Beacon Wiring Harness , Combination Switch , Fender Lamp , Flasher Unit Assy. , Hazard Switch , Head Lamp Assy , Holder Rod , Horn Assy (High Tone) , Horn Mounting Bracket , Instrument Cluster , Main Wiring Harness , Oil Pressure Sensor , Relay , Socket Assy. , Starter Switch Assy. , Stop Switch , Alternator Assy , Engine Assy. , Engine Oil , Plate Adjusting , Spacer Alternator , Starter Motor , Gasket Silencer , Manifold Exhaust , Nail Rivet , Round Silencer , Steering Cylinder , Pivot Pin Assy. , Thrust Washer , Bevel Pinion Shaft , Crown Wheel & Tail Pinion , Locking Washer(Crown Wheel) , Washer Bevel Pinion , Tail Pinion Carrier , Assy. Trumpet Housing Front , Gear Oil , Trumpet Housing , Assy Steering Arm , Assy. Front Axle Housing , Bearing , Bevel Gear , Front Axle , Gasket Steering Arm , Steering Arm , Stub Axle , Clip. Hose , Fuel Feed Pump , Fuel Filter Assy. , Fuel Pipe , High Pressure Pipe , Hose Clip , Hose Fuel , Injector Over Flow Pipe , Joint Three Way , Nozzle & Holder Assy. , Strainer Plus Pipe Assy. , Ext. Circlip , Halical Gear , Intermediate Shaft , Lay Shaft , Needle Bush , Oil Seal , Tapper Roller Brg , Conical Spring , Dipstick , Gear Shifter , Lever Assy , ORing , Pin Assy. , Rubber Boot , Spring , Z-Plate , Bolt Governor Case , Bolt. High Speed Set , Case Governor , Cover Torque Set , C-Ring Torque , Gasket Governor Case , Lever Governor , Lever Speed Control , Nut Torque Set , Pin Spring , Screw Assy. Back Set , Shaft Governor , Shaft Sliding Sleeve , Shim. Governor Shaft , Sleeve Sliding , Solenoid Assy. , Spring Governor , Spring Start , Spring Tie Rod , Washer Spring , Weight Assy. Governor , Encl. In Seat Kit , External Circlip , Kit Crank , Kit Cylinder , Kit Piston , Shaft , Hydraulic Lift Assy. , Lever , Kit Relief Valve , Lift Body Assy , Lub Oil Filter , Oil Pump Assy. , Strainer Assy. Oil , Switch Oil Pressure , Valve Assy. Relief , Drain Plug , Brake Pedal , Clutch Pedal Assy. , Hinge Pin , Knob Assy- Parking Brake , Link Pin , Tie Rod Assy , Draft Lever , Knob Assy. - Operating Sector , Knob Lever , Position Lever , Clamp , Gear Pump , Hsu Pipe , Nipple , O-Ring , Reduction Hose , Steering Column Assy. , Suction Pipe , Suction Strainer , Trolly Pipe , Ball Brg , Cover (Pto Shaft) , Pto Gear , Pto Lever Assy. , Pto Shaft , Pto Sliding Gear , Air Valve Assy , Industrial Tyre , Rear Axle , Rim Rear , Spacer , Turf Tyre , Wheel Rim , Wheel Tyre , Front Tyre , Rear Tyre , Axle ( Foot Throttel ) Assy. , Bonnet Assy. , Dashboard Assy. , Fender Assy , Foot Board Assy , Foot Throttle Assy , Fuel Tank , Hand Accelerator Assy , Head Light Frame , Meter Plate , Mounting Strip , Mtg Pin , Push Rod Assy. , Rear View Mirror , Reflex Reflector , Side Cover -Radiator , Spring Cotter , Strap Clamp , Tail Lamp Bkt. Assy , Dome Sticker Round , Front Wheel Rim , Rim Front , Steering Wheel , Tyre (Rear & Front) , Adjustable Ancher Chain , Back Plate Rops (For 1026E) , Bush Plate Assy. , Draw Bar Assy. , Hook Pin , Linch Pin Assy , Lower Link Assy. (Lh&Rh) , Pin-Lift Rod , Pin-Top Link Assy. , Shaft Lower Link Assy. , Bolt Rocker Bracket , Bracket Rocker Shaft , Bush Idler Gear , Camshaft , Cap Oil Filler , External Circlip A-19 , Gasket Cover Assy. , Gear Assy. Idler , Gear Camshaft , Gear Fip , Rocker Assy. , Shaft Assy. Rocker , Spring Rocker , Bearing Hsg. , Gasket , Fan Belt(B-37) , Fan Cooling , Fan Spacer , Gasket Water Pump , Plate Water Pump , Pulley Water Pump , Water Pump Assy. , Actuator Assy. , Brake Lever-Parking Brake , Cover -Brake Housing , Friction Disc , Gasket Brake Housing , Gear Oil Wet Brake , Steel Disc , Swiel Block , Wet Brake , Wheels & Tyres , Tractor Trolly , Wheels & Tyres , Chasis/Frame , Trolley Body , Axle & Hub Assembaly , Hydraulic Jack/Sylinder , Toing Channel/Drawbar , Braking System , Tailgate , Lights , Reflectors , Stablizer Jack , Cuplink , Velding Work , Painting Work , Other Fabrication/Repair Work , Water Tanker Supply , Battery , Charger 51.2V/100Ah , Charging Socket Set , Hydrolic & Compressor Repairing , Controller (1000 Watt) , Convertor , Full Electrical Wiring , Drl Led Head Light , Back Horn , Indicator Bulb Front , Indicator Bulb Back , Key Lock , Motor (1000 Watt) , Paint , Accelerator Mutha , lane road Mutha , Body Repairing/Velding Work , Speedometer , Flasher , Hydraulic Set With Remote , Labour Charges , Water Supply Tanker , Wheels & Tyres , Chasis/Frame , Trolley Body , Axle & Hub Assembaly , Hydraulic Jack/Sylinder , Toing Channel/Drawbar , Braking System , Tailgate , Lights , Reflectors , Stablizer Jack , Cuplink , Velding Work , Painting Work , Other Fabrication/Repair Work
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 1.07 Crore
Boards / Undertakings / PSU No of Bidders 1
Jammu And Kashmir View Result →
12.
Public Administrative Department #10852137 Technical Bid
Tender For Supply, Installation And Commissioning Of Machinery For Shree Saibaba I.T.I, Shirdi. Tools, Equipment, Instrument List (As Per New Syllabus -All Trade) 1) Trade- Fitter , Pipe Cutter 6 To 25Mm Wheel Type Make - Stanley/ Ingco/Taparia / Bharat /Jk , Pipe Bender Spool Type Up To 25.Mm With Stand Manually Operated Make - Beekay / Breeze /Indar/ Voltz /Stanley , Ss And Sc Centre Lathe (All Geared) With Minimum Centre Height 6/150 Mm & Center Distance 1000 Mm Along With 3, 4 Jaw Chuck, Auto Feed System, Coolant Arrangement, Lightening Lamp, Taper Turning Attachment, Safety Guard & Standard Accessories. Make - Kirloskar / Hmt / S Micrometric , Drilling Machine Pillar Sensitive 0-20 Mm Capacity With Swivel Table Motorize With Chuck & Key Make - Panchal / Skp / Eifco /Makita , Drilling Machine Bench Sensitive 0-12 Mm Capacity With Motorize With Chuck & Key Make -Panchal /Skp / Eifco / Makita , Compressor Unit:- Suitable For Pressure - 8 Bar, Delivery-50Lpm Or More, Receiver Capacity-24 Liters Or More, 250V,50 Hz, With Pressure Regulator And Water Separator Make - Fuji / Air Master/ Elgi/Ingersol Rand , Pneumatic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories. Single Acting Cylinder- Max. Stroke Length 50Mm, Bore Dia 20Mm - 1 No. Make - Extreme / Genitic / Parker / Koganei , (Ii) Double Acting Cylinder - Max.Stroke Length 100Mm, Bore 20Mm, Magnetic Type - 1 No. , (Iii) 3/2 Way Valve Manually-Actuated, Normally Closed. - 2 Nos. , (Iv) 3/2- Way Valve Pneumatically-Actuated Spring Return 1 No. , (V) One Way Flow Control Valve - 02 Nos. , (Vi) 5/2-Way Valve With Manually-Operated Switch-1No. , (Vii) 5/2 Way Valve-Pneumatically Actuated Spring Returns. , Viii) 5/2 Way Pneumatic Actuated Valve Double Point-1 , (Ix) 3/2 Way Roller Lever Valve Direct Actuation Normally Closed. - 02 Nos. , (X) Shuttle Vale - 01 No. , (Xi) Two Pressure Valve (And) - 01 No. , (Xii) Pressure Gauge 0-16 Bar - 01 No. , (Xiii) Manifold With Self-Closing Nrv-6 Way - 01 No. , (Xiv) Push Button Station For Electrical Single Point With 3 Illuminated Momentary-Contact Switch (1No + 1 Nc) And 1 Illuminated Contact Switch (1No+1Nc), Contact Load 2 A.- 01 No. , (Xv) Relay Station- With 3 Relay Each With 4 Contact Set (3No + 1Nc) Or Change Over Type, 5 A. - 01 No. , (Xvi) 3/2 Way Single Solenoid Valve With Led - 01 No., , (Xvii) 5/2 Way Single Solenoid Valve With Manual Override And Led - 01 No. , (Xviii) 5/2 Way Double Solenoid Valve With Manual Override And Led - 01 No. , (Xix) Power Supply Unit - Input Voltage 85-265V Ac, Output Voltage; 24V Dc, Out Put Current-Max.4.5A., Short Circuit Proof. - 01No. , (Xx) Profile Plate, Anodized Aluminum. 1100X700Mm. With Carriers, Maintenance Of Punting Frames And Mounting Accessories (Tube Fitted On To The Pneumatic Workstation. - 01 Set , Pneu, Matic Workstation With 40 Square Mm Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handle And Individual Locks, On Metallic Full, Panel Drawer Slide , (1) Work Table Size 1200Mm (L) X900Mm (W) X900Mm. (H), With Four Custard Wheel Including Two Lockable Wheel At The Front Side. , Drawer Size - L 460 Mm X W 495Mm. X H 158Mm. Each And Overall Size Of Drawer Unit (Apex) L 470Mm X W 495Mm X H 825Mm , (3) Drawer Slide Height (Apex) 85Mm. , Carrier For Mounting Components, Such As Pb & Relay Boxes. Cut Section Model For Pneumatic Components. , Hydraulic Trainer Kit, Each Consisting Of The Following Matching Components And Accessories Make - Hitachi / /Tecno / Power Tech / Cad Mech Engineering / Equator Hydraulic , 1) Hydraulic Power Pack: - With (1) External Gear Pump Having A Delivery Rate Of 2.5 Improvement (Apex) (A) 1400 Rpm Operating Pressure 60 Bar, Coupled To A Single-Phase Ac Motor (230V Ac) Having Starter Capacitor And On/Off Switch And Overload Protection, , 2) Pressure Relief Valve Adjustable From 0-60 Bar , 3) Oil Reservoir, 5 Liters Capacity Having Sight Glass, Drain Screw, Air Filter And P And T Ports. - 01 No. , Ii) Pressure Relief Valve Pilot Operated - 01 No. , Iii) Drip Tray, Steel 1160Mmx760Mm. - 01 No. , Iv) Pressure Gauge Glycerin- Damped, Indication Range Of 0-100 Bar. - 01 No. , (V) Four-Way Distributor With Five Ports, Equipped With A Pressure Gauge. - 01 No. , (Vi) Double Acting Hydraulic Cylinder With A Control Cam, Piston Diameter 16Mm.,Piston Rod Diameter 10Mm,Stroke Length 200Mm. - 01 No. , (Vii) Suitable Weight For Vertical Loading Of Hydraulic Cylinder - 01 No. , (Viii) Mounting Kit For Weight For Realizing Pulling And Bushing Lead. - 01 No. , (Ix) 3/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (X) 4/2 Way Directional Control Valve With Hand Lever Actuation - 01 No. , (Xi) 4/3 Way Directional Control Valve. Closed-Center Position, With Hand Lever Actuation - 01 No. , (Xii) Non Return Valve - 01 No. , (Xiii) Pilot Operated Check Valve Pilot To Open -01 No , (Xiv) One Way Flow Control Valve With Integrated Check Valve. - 01 No. , (Xv) T-Connector With Self-Sealing Coupling Nipples (2 Nos.) And Quick Coupling Socket (1 No.) - 02 Nos. , (Xvi) Profile Plate: - Anodized Aluminum, 100X700Mm With Carriers, Mounting Frames And Mounting Accessories (To Be Fitted Onto The Hydraulic Work Station. - 01 Set , Hydraulic Work Station With 40 Square Mm. Aluminum Profile Legs, Wooden Work Surface, And One Pedestal Drawer Unit Having 5 Drawers, Each With Handles And Individual Locks, On Metallic Full Panel Drawer Slide. , (1) Work Table Size (Apex) L1200Mm. X W900Mm. Xh900Mm. With Four Castor Wheel Including Two Locale Wheel At The Front Side. , Drawer Size (Apex) L460 Mm X W495Mm. X H158Mm Each, And Overall Size Of Drawer Unit (Apex). L470Mm X W495Mm. X H825Mm. , (3) Drawer Slide Height (Apex) 85Mm. Cut Section Models For Hydraulic Components. , D.C. Shunt Generator With Control Panel,2.5 Kw, 220V & 3 Phase Squirrel Cage Induction Motor, 5 Hp,440V With Control Panel & Star Delta Starter 1) Dc Generator Make - Crompton / Bharat Ele. Motor/ Kirloskar / Electronech / Power Way Systems 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor-Generator (Ac To Dc) Consisting Of : Squirrel Cage Induction Motor With Star Delta Starter And Directly Coupled To Dc Shunt Generator And Switch Board Mounted With Regulator, Air Breaker, Ammeter, Voltmeter, Knife Blade Switches And Fuses, Set Complete With Case Iron And Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Induction Motor Rating ;- 7.5 Hp, 415V, 50 Cycles, 3Phase Dc Shunt Generator Rating ;- 5Kw,440V (Output Voltage Varies 110-440V) 1) Dc Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) 3- Phase Induction Motor Make - 1. Crompton 2. Siemens,3. Hindustan Electric Motor. 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Series Motor Coupled With Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Shunt Motor Control Panel Including Spring Balance Load 2.5 Kw; 220Volts 1) Dc Series Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Dc Compound Motor With Control Panel Including Spring Balance Load, Starter And Switch- 2.5 Kw, 220Volts 1) Dc Compound Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Motor Generator(Dc To Ac) Set Consisting Of - Shunt Motor With Starting Compensator And Switch Directly Coupled To Ac Generator With Exciter And Switch Board Mounted With Regulator, Breaker, Ammeter, Voltmeter Frequency Meter, Knife Blade Switch And Fuses Etc. Set Complete With Cast Iron Bed Plate, Fixing Bolts, Foundation Bolts And Flexible Coupling. Shunt Motor Rating: - 5Hp, 440V, A.C., Generator Rating: - 3-Phase, 4-Wire, 3 Kva, 400/230 Volts, 0.8Pf, 50Cycles. 1) Dc Shunt Motor Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar /Abb /Siemens 2) A. C. Generator Make - 1. Kirloskar 2. Crompton, 3. Siemens / Abb 3) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Squirrel Cage Motor With Star Delta Starter And Triple Pole Iron Clad Switch Fuse With Mechanical Loa,5 Hp,3-Phase ,415 Volts, 50 Hz 1) Ac Squirrel Cage Motor Make - 1. Crompton, 2. Siemens, 3. Hindustan Elec. Motor /Abb / Siemens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Ac Phase-Wound Slip Ring Motor With Control Panel ,Starter And Switch 5 Hp, 440 V, 3-Phase, 50 Hz 1) Ac Phase-Wound Slip Ring Motor Make - 1. Crompton, 2. Siemens, 3. Havells Motor /Abb / Simens / Bbl 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard , Universal Motor With Control Panel, Starter/Switch 240 Volt, 50 Hz, 1 Hp 1) Universal Motor Make - 1. Crompton Greaves, 2. Hindustan Motor /Agni Motors / Integrated Elect Construction Of 3. Siemens / Bosch Power Tool 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Synchronous Motor With Control Panel Accessories. Like Starter, Excitation Arrangements,-3 Phase, 3 Hp, 440V, 50Hz, 4 Pole, 1) Synchronous Motor Make - 1. Kirloskar, 2. Crompton, 3. Siemens / Abb 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor /Igbt Controlled D.C. Motor Drive With Tacho-Generator Feedback Arrangement 1 Hp (Complete Set) 1)Thyristor /Igbt Controlled D.C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb / Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Thyristor / Igbt Controlled A.C. Motor Drive With Vvvf Control 3 Phase, 2 Hp (Complete Set) 1) Thyristor /Igbt Controlled A .C. Motor Drive Make - 1. Crompton Greaves 2. Siemens, 3. Electro Plasto Control (Epc) /Abb /Siemens 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Transformer, Core Type, Air Cooled, 1 Kva , 240/415 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Technovision Energy /Servokon /Sahara , Three Phase Transformer, Shell Type, Oil Cooled With Delta / Star 3 Kva , 415/240 V, 50 Hz Make - 1. Siemens India 2. Kirloskar Electric Company Ltd 3. Bharat Heavy Electrical / Servocon / Kay Pee , Electrical Machine Trainer - Suitable For Demonstrating The Construction And Functioning Of Different Types Of Dc Machines And Ac Machines (Single Phase And Three Phase). Should Be Fitted With Friction Brake Arrangement, Dynamo Meter, Instrument Panel And Power Supply Unit. 1) Dc Machines And Ac Machines Make - 1. Crompton 2. Kirloskar, 3. Siemens / Kitek Technology /Anshuman Tech 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Diesel Generator Set With Change Over Switch, Over Current Breaker And Water/ Air-Cooled With Armature, Star-Delta Connections Ac 3 Phase, 7.5 Kva, 415 Volt Or Higher Rating Make - 1. Kirloskar 2. Cummins 3. Mahindra Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Pillar Electric Drill Machine Motorized 12-20Mm. Capacity, 1 Hp,440V,3 Phase, Induction Motor With Dol Starter, Bench Type 1) Electric Motor -1. Crompton 2. Kirloskar 3. Siemens 2) Drill Machine Piller - 1. Prakash Engitech Pvt. Ltd. 2. Sri Vigneshwara Machine Tools. 3. Yogi Machine Tools / Itco Engg/ Liberty Metal /Jeet Machine , A.C. Series Type Motor With Control Panel 1 Hp, 240 V, 50 Hz 1) A.C. Series Type Motor Make - 1. Crompton 2. Kirloskar,3. Siemens /Abb / 2) Control Panel- Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Single Phase Capacitor Motor With Control Panel , Starter Switch 1 Hp 240 Volt 50 Hz 1) Single Phase Capacitor Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Kirloskar 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Manual Motor Coil Winding Machine - With Step Arbour Make - 1. Chawla And Chudhari Trading Co. Pvt 2. Bgi Tools And Machine 3. Shree Esha Winding Technology / Sigva / Signatt / Heaven , Ceiling Fan Coil Winding Machine - 250V,50Hz, 1- Phase With Speed Control Make - 1. Bharat Machine Tools Ind. 2. Nishan Electric 3. Jangir Engineering Work / Kisan Engg / Nilkanth Electric , Primary Current Injection Set 220V,50Hz, 1-Phase,Output Current-200A(Min) With Timer Make - 1. Sb Electro Tech. 2. Pragati Process Controls, 3. Scope T&M Pvt / Udeytaj Electric / Motwane /Kpm Engg , Stepper Motor With Digital Controller Make - 1. Ajanta Export Industries. 2. Anubhuti Power System 3. Bombay Electronics 4. Siemens 5. Schneider Elect 6. Abb , Shaded Pole Motor Fractional Hp, With Control Panel 240V 50Hz 1) Shaded Pole Motor Make - 1. Crompton Greaves 2. Hindustan Motors 3. Siemens Motors / Rexnord 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , D.C. Compound Generator With Control Panel Including Fitted Rheostat, Voltmeter, Ammeter & Breaker, 2.5 Kw, 220 V & 3 Phase Squirrel Cage Induction Motor 5 Hp, 440 V With Control Panel & Star Delta Starter. Make - Dc Compound Generator Make - 1. Crompton, 2. Bharat Ele. Motor, 3. Kirloskar / Powerol 3- Phase 1) Induction Motor Make - 1. Crompton 2. Umiya Trading Company 3. Envirotech Engineers 2) Control Panel - Control Panel Accessories, Equipment And Protecting Accessories As Per Isi Standard. , Used D.C. Generator Series, Shunt & Compound Type For Overhauling Practice. Make - 1. Crompton, 2. Bharat Ele. Motor 3. Kirloskar , Smart Meter 1- Phase - Smart Energy Meter 3 - Phase - Smart Energy Meter Make - 1.Genus Power Infrastructures Ltd 2.Hpl Electric & Power 3.Elmax India / L&T Electric , Ev Charger 3 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronic / Servotech Power System , Ev Charger (Home) 1 - Phase Input Make - 1. Tata Power 2. Mahindra Electric 3. Okaya / Delta Electronics , Work Shop Main Control Panel With Voltmeter Indicator Ammeter Indicator 1. Maintenance 125 A 440V 2. Output Main Switch - 16A - 08 , 32A - 08 63A - 02 Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , D C Control Panel Income - 440V Ac Output -12V ,24,110V, 240V, 440V, Dc With Indicator Voltammeter Ampire Meter Make - 1. Schneider Elect 2. Siemens 3.Abb 4. L& T , Welding Transformer With All Accessories ( 400A, Ocv 60-100 V, 60% Duty Cycle) Make - Miller / Ador / Esab / I Bell , Welding Transformer (Or) Inverter Based Welding Machine With All Accessories (300A , Ocv 60 - 100 V, 60% Duty Cycle) Miller / Ador / Esab / I Bell , D.C Annual Rate Contract Welding Rectifiers Set With All Accessories (400 A. Ocv 60 - 100 V, 60% Duty Cycle ) Make - Miller / Ador / Esab / Vigor , Gmaw Welding Machine 400A Capacity With Air Cooled Torch, Regulator, Gas Preheater, Gas Hose And Standard Accessories Miller / Ador /Esab / Kemppi , Ac/Dc Gtaw Welding Machine With Water Cooled Torch 300 A, Argon Regulator, Gas Hose, Water Circulating System And Standard Accessories. Miller /Ador / Esab / I Bell / Lincoln , Air Plasma Cutting Equipment With All Accessories, Capacity To Cut 12 Mm Clear Cut Make -Miller / Esab / Hypertherm / Rali Wolf / Technocard Plasma , Air Compressor Suitable For Above Air Plasma Cutting 15 Kw System Two Stage Compressor. 225 Ltr. Auto Cut Tank Cap. 80 -100 Psi Make -Elgi /Allas Capco / Ingersoll Rand / Premier , Auto Darkening Welding Helmet Make -L&T / Bell / Esab / Miller , Spot Welding Machine To 15 Kva With All Accessories Make - Ador / Esab/Artech / Micro Weld , Portable Gas Cutting Machine Capable Of Cutting Straight & Circular With All Accessories Make - Esab/ Pug Nm / Koike India /Ador / Pentagon , Pedestal Grinder Fitted With Coarse & Medium Grain Size Grinding & Wheel Dia-300Mm. Make -Elmaco / Bosch / Vijay Foundry Equipment , Bench Grinder Fitted With Grain Size Silicon Carbide Green Grinding Wheel Dia 150Mm Make - Elmaco / Bosch / Dewalt / Stanley Corded , Power Saw Machine 18 Hp-300 Blade Size - 450 Mm Make -Bosch / Dewalt / Hitachi / Kmi / Atlas Mochal , Portable Drilling Machine Capacity 6Mm. Make - Bosch / Dewal/ Hitachi , Oven Electrode Drying 0To 350C 10Kg Capacity Make - Ador /Arcon /Senso Heat , Die Penetrating Testing Kit. (Machine) Make - Esab / Dubi-Chek / Aerol / Magnaflux , Magnetic Particle Testing Kit. Make -Esab / Canmay /Mag Flux / Magnaflux / Magkraft , Wedding Simulators For Smaw,Gtaw,Gman (Optional) Make - Krb Electronic Soln Rewabsi / Simbott , Water Cooled Induction Welding/ Brazing Machine 200-250 Amp., Induction Coil Length 3 Inch And 2.5 Inch Make - Esab /Micro Tech Induction /Foster Induction /Vel I Braze Snapet / Welding World , Plastic Welding Machine With Hot Air Gun Temp. Display, Variable Temp., Pe, Pp& Pvc Sheet Or Pipe Welding Control With Stand. Accessories. Make - Esab / Leister / New Vimco Ltd /Ajanta Ultra Plast / I Bell / Vormik Vr/Branson Ultrascnies , Ag4 Grinder 100 Mm Dia Make - Dewalt / Bosch /Jk Supper / Metabo , Portable Abrasive Cut Off Machine 107 Mm Dia Make - Dewalt / Bosch / Ingco Hikoki /Mangalam / Century / Emboro , Hand Shearing Machine Cp Cut 6 Mm Sheet & Flat Make - Shakti / Vmt/ M.S. Machine Tools/Tl Pathak Group , Laser Cutting Machine Portable 50 Mm Laser Make - Esab / Toumf / Amada / Parag Weld Algo Laser/ Auto Mstack/Crealrty , Lathe S.S. & S.C. (All Geared Head Stock) With Minimum Specification As: 150Mm Centre Height To Admit 750Mm Between Centres, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 150Mm., 3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Travelling Study, Face Plate, Driving Plate, 4 Way Tool Post, Quick Change Gear Box For Metric Or British Threads, Live And Dead Centre With Taper Turning Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar /Hmt/ S Micrometric , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Between Centers, Machine To Be Motorized And Supplied With Coolant Installation, 4-Jaw Independent Chuck 250Mm.,3-Jaw Self-Cantering Chuck 150Mm. Fixed Steady, Traveling Steady, Face Plate, Driving Plate 1-Way Tool Post, Draw In Type Collets Set Up To 25 Mm, 0.5 Mm Relieving Attachment Motor Capacity 5.5 Kw. Mt 2 Revolving Centre Qty.2 No. Make - Kirloskar / Hmt / S Micrometric , Grinding Machine Pedestal Type D.E.200Mm. Dia. Wheel With Wheel Guard And Vision, Motor Capacity - 0.75 Kw. Make - Elmaco / Bosch / Ingco , Cnc Lathe/Cnc Turn Centre Make - Bfw / Moriseiki / Makino , 1) Machine Capacity A. Swing Over Bed - 350 Mm Or Higher B. Turning Diameter - 135 Mm Or Higher C. Distance Between Centers - 250 Mm Or Higher D. Maximum Turning Length - 200 Mm Or Higher E. Slant Angle (Bed Or Saddle) -30 Degrees To Horizontal Or Higher F. Cast Iron Grade For Bed And Saddle - Grade 25 Or Equivalent G. Machine Weight Net - 1500 Kg Or Higher , 2) Spindle A. Spindle Nose -A2-4 / A2-5 B. Bore Through Spindle - 35Mm Or Higher C. Maximum Spindle Speed - 4000 Rpm Or Higher D. Spindle Power, Continuous - 3.7 Kw Or Higher E. Minimum Spindle Speed @ Full Power - 1200 Rpm, Or Lower F. Type Of Drive - Ac Servo Spindle Motor (Digital) G. Chuck Size -135 Mm Or Higher. Chuck Type H.3-Jaw Hydraulic, Hydraulic Power Operated I. Spindle Bearing Class - P4 Class J. Front Bearing Dia. (Id) - 60 Mm Or Higher , 3) Axes A. X - Axis Travel - 100 Mm Or Higher B. Z - Axis Travel -200 Mm Or Higher C. Programmable Feed Rate- X & Z -10 - 10000 Mm/Min D. Minimum Programmable Command -X & Z - 0.001 Mm E. Rapid Traverse - X & Z - 20 M/Min Or Higher F. Type Of Drive - X & Z - Ac Servo Motor G. Motor Torque - Z Axis - 3Nm Or Higher H. Motor Torque - X Axis - 3Nm Or Higher With Brake I. Ball Screw - Z & X Axes (Diameter X Pitch) - 25 X 10 Mm Or Higher J. Ball Screw Finish - Z & X Axes - Hardened And Ground K. Ball Screw Class- Z & X Axes - Pre-Loaded With C3 Or Better L. Guide Way Type - Z & X Axes - Antifriction Linear Motion Guide Way M. Guide Way Size - Z & X Axes - 25Mm Or Higher N. Guide Way Precision - Z & X Axes - P Class , 4) Turret A. Bi-Directional Tool Turret - Electromechanical/Servo/Hydraulic B. No. Of Tools - 8 Nos. Or Higher C. Tool Shank Size - 20 X 20 Mm Or Higher D. Maximum Boring Bar Diameter - 25 Mm Or Higher , 5) Tail Stock A. Quill Diameter - 65 Mm Or Higher B. Quill Stroke - 70 Mm Or Higher C. Quill Taper- Mt-4 Or Higher D. Quill Actuation - Hydraulic E. Tail Stock Base Travel Manual - 150 Mm Or Higher F. Thrust (Adjustable) - 300 Kg For Higher , 6) Coolant/Lubrication/Hydraulic A. Coolant Tank Capacity - 100 Liters Or Higher B. Coolant Pump Motor - 0.37 Kw C. Coolant Pump Out Put - 20 Lpm Or Higher D. Lubrication Type - Automatic Centralized Lubrication E. Lubrication Tank Capacity 3 Liter Or Higher F. Hydraulic Pump Discharge - 8 Lpm Or Higher G. Hydraulic Tank Capacity - 30 Liters Or Higher H. Hydraulic System Pressure Maximum -30 Bar Or Higher , 7) Accuracy As Per Iso 230-2 A. Positioning Accuracy X & Z Axes - 0.012Mm B. Repeatability X & Z Axes - ± 0.007Mm C. Geometrical Alignment - Iso 13041-Part 1 D. Accuracy Of Finish Test Piece - Iso 13041-Part 6 , 8) Cnc System A. Control System - Fanuc / Siemens B. System Resolution - 0.001 Mm C. Motors & Drives - Compatible With Cnc Controllers Mentioned Above D. Tool Number Display - On Machine Operator Panel E. Machine Control Panel - Feed Rate, Spindle Speed Override Knob F. Mpg (Manual Pulse Generator) - On Machine Operator Panel G. Cnc Features - Graphic Simulation, Programming Help, Tool Offsets, Mdi, Absolute/ Incremental Positioning, Pitch Error Compensation , 9) Power Source A. Mains Supply (± 10 %) - 415 V, 3 Ph., 50Hz B. Total Connected Load Requirement - Approx. 15 Kva , 10) Standard Equipment A. Voltage Stabilizer 15 Kva B. Air Conditioning Unit For Electrical Cabinet - 1 No. Backup Cd For Plc Ladder Logic - 1 No. D. Machine Lighting - 1 No. E. Levelling Pads And Jacking Screws - 4 No. F. Operation Manual - 1 No. G. Maintenance Manual - 1 No. H. Installation Kit - 1 No. I. Maintenance Tool Kit - 1 No. J. 6 Rack Trolley (Size 25X22X45) With Lock - 1 No. K. Machine Guarding With Safety Compliance - 1 No. , 11) Makes Of Critical Machine Tool Components A. Linear Motion Guide Ways - Hiwin/Thk/Pmi/Star B. Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C. Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D. Turret - Pragati/Baruffaldi/Sauter/Duplomatic E. Hydraulic Chuck & Cylinder - Gmt/ Kitagawa / Airtech /Pragati / Rohm F. Hydraulic Power Pack - Yuken/Fluid/Rexroth G. Panel Ac - Werner Finley/Rittal/Lextecnoid H. Stabilizer - Neel/Servomax /Consul/Farmax/Equivalent I. Lubrication- Cenlube/Dropco/Equivalent J. Coolant Pump - Rajamane/Grundfos K. Cutting Tools And Holders - Sandvik/Taegutec/ Kennametal /Seco/Iscar/Mitsub Ishi , 12) Cutting Tools & Tool Holders 1. External Turning Holder, Insert Type, Mwlnl - Holder 4Qty. (Insert Wnmg 40 Nos.) 2. External Turning Holder, Insert Type, Mvjnl - Holder 4Qty. (Insert Vnmg 20 Nos.) 3. External Turning Holder, Insert Type, Pdjnr - Holder 4Qty. (Insert Dnmg 20 Nos.) 4. Threading Holder - External, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 5. Threading Holder - Internal, Lh - Holder 4Qty. (Insert 0.5 To 2 30 Nos.) 6. Grooving Holder External, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 7. Grooving Holder Internal, Lh - Holder 4Qty. (Insert 3Mm 30 Nos.) 8. Parting Off Holder For Insert Width 2 Mm, Lh - Holder 4Qty. (Insert 2Mm 30 Nos.) 9. Boring Holder Sclcl For Minimum Bore Dia. 12Mm - Holder 4Qty. (Insert Wcmt 60 Nos.) 10. Boring Holder Sclcl For Minimum Bore Dia. 16 Mm - Holder 4Qty. (Insert Ccmt 60 Nos.) 11. Internal Grooving Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert 2Mm 30 Nos.) 12. Internal Threading Holder Lh, For Minimum Bore Dia. 12 Mm - Holder 4Qty. (Insert W Mm 30 Nos.) 13. Insert Drill 12.7 Mm - Holder 4Qty. (Insert Suitable 30 Sets.) 14. Reducing Sleeves For Internal Holders - Dia 12 And 16 Mm - 2 Sets 15. Centre Drill Hss A 2.5 X 6.3 - 6 Qty. 16. Twist Drill Hss Straight Shank, Dia 6,8,10,12 Mm - 6 Sets 17. Collets Suitable For The Above Drills - 2 Sets 18. Collet Holder - 4 Nos. 19. Boring Bar Holder - 3 Nos C.N.C Lathe Machine With Accessories. 1. D- List Of Additional Machines, Tools And Equipment For Cnc Turn Center : D) Digimatic Electronic Vernier Caliper 200 Mm. - 2 Nos. E) Digimatic Electronic Outside Micro Meter (0 To 25 Mm & 25 To 50 Mm) Lc 0.001 Mm. - 1 Nos Each. , Desktop Computers Compatible To Run Simulation Software With Lan Facility. Dell / Lenovo / Hp Specification - Cpu - 64 Bit I7 Or Latest Processor Speed - 3Ghz Or Higher Ram 12 Gb Ddr - Iii Or Higher, Wi-Fi Enabled. Network Card - Integrated Gigabit Ethernet, With Usb Mouse, Usb Keyboard And Monitor (Min. 21 Inch.) Licensed Operating System And Antivirus Compatible With Trade Related Software. 01 Tb Hard Disk Nvidia Graphic Card , Ss And Sc Centre Lathe (All Geared) With Minimum Specification As: Centre Height 150 Mm And Centre Distance 750Mm Along With 4 Jaw Chuck, Self-Centering Chuck, Auto Feed System, Safety Guard, Motorized Coolant System And Lighting Arrangement, Set Of Lathe Tools, Lathe Carriers Make - Kirloskar /Hmt/ S Micrometric , Pillar Drill Machine (All Geared) 0-25Mm Drill Holding Capacity With Drill Chuck & Keys. Make - Ifco/ Skp / Energi , Cylindrical External Grinding Machine Fully Motorized With Dressing Arrangement And Supplied With Face Plates And Driving Dogs, 3 Jaw Self-Centering Chuck,4 Jaw Independent Chuck, Tail Stock Assorted Center Pump With Tank And Pipe Fittings Spanners And Grease Gun (Each Machine To Be Supplied With Assorted Grinding Machine For General Purpose Work With Internal Grinding Attachment) With Minimum Specification As: To Accommodate 750Mm Job With Center Height 150Mm. Wheel Diameter X Width=300X25Mm Make - Hmt-K 130 U / S-Micrometic / Hi Life , Radial Drilling Machine 32Mm Diameter With Std. Accessories. Drill Chuck & Plain Machine Vice 250 Mm Make - Hmt / Bfw / Batliboi , Lathe Tool Room S.S. & S.C. . . . (All Geared Head Stock) With Minimum Specification As : 150Mm Center Height, 1000Mm Long With 3-Jaw, 4-Jaw Chuck Auto Feed System, Taper Turning Attachment, Coolant Pump, Safety Guard, And Machine Light Arrangement. Make - Kirloskar / Hmt / S Micrometric , Rockwell Hardness Testing Machine Digital Type With Standard Accessories / Digital Type Make - Mitutoyo/ Sagar/ Sinowon / Saroj / Sai Dro , Profile Projector (5 Micron) Re Solution 0.001Mm Projection Scream - Effective Diameter 300 Mm, Rotation Angle: +/- 360 Degree Angle Reading - 0.01 Degree Or 1 (Commutative) Projection Lens - 10 X Lens Group (Standard Arrangement) 20X50X100 X Is Set As On Option. Measuring Range - 200X200 Mm Quickly Move X, Y Axes, Power : 220 Vac Make - Mitutoyo / Nicon / Metzer , Co-Ordinate Measuring Machine (5 Micron) Measuring Range 500X700X500Mm Make - Nicon / Mitutoyo / Devine Technology , Fly Press (Any Model Minimum 12 Tons Capacity) Make - Taj Enterprises / Bharat Machinery And Spares / Orient Machine Tool , Power Press M/C (Hydraulic) Minimum 02 Tons Capacity Standard And Required Optional Accessories Make - Foreman / Amino / Omkar Enterprises , Auto Cad & Cam Latest Version - For Training Purpose Make - Autodesk , Solid Works / Any Latest - Latest Version - For Training Purpose Make - Dassasult System Solid Work Corporation , Smart Touch Screen Panel For Smart Class Room (65) Usb Connector, Led Interactive Pen, Mounting, Users Manual Electronics File Make - Samsung / Smart Guru / Vincon System , Multimedia Based Simulator For Cnc Technology & Interactive Cnc Part Programming Software For Turning & Milling With Virtual Machine. Operation & Simulation Using Popular Operation. Control System Such As Fanuc, Siemens, Etc. (Web-Based Or Licensed Based.) - For Training Purpose Make - Cad Mech / Indiasoft / Fanuc / Krb Electronic Solution , Cnc Vertical Machining Centre With Std. Accessories Make - Bfw / Moriseiki / Makino Specification , 1) Machine Capacity A)Table Size - 500X250 Or Higher Mm B) Max. Load On Table 150 Or Higher C)T Slot Dimension (N X W X P) Mm 3X14X100 Or Higher D)Table Height From Floor 800 ~ 900 Mm E) Cast Iron Grade For Bed And Saddle Grade 25 Or Equivalent F)Machine Net Weight 1500 Or Higher Kg , 2) Spindle A) Spindle Nose Bt30 B) Minimum Distance (Spindle Nose To Table)100 - 150 Mm D) Maximum Spindle Speed 6000 Or Higher Rpm E) Spindle Power, Continuous 3.7 Or Higher Kw F) Type Of Drive Ac Servo Spindle Motor (Digital) G) Spindle Bearing Class P4 H) Front Bearing Dia. (Id) 50 Or Higher Mm , 3) Axes A) X - Axis Travel 300 Or Higher Mm B) Y - Axis Travel 250 Or Higher Mm C) Z - Axis Travel 250 Or Higher Mm D) Rapid Traverse - X/Y/Z 20/20/20 Or Higher M/Min E) Minimum Programmable Command X/Y/ Z - 0.001 Mm F) Programmable Feed Range - X, Y & Z Axes 10 - 10000 Mm/Min G) Type Of Drive Ac Servo Motor H) Motor Torque - X & Y Axes 3 Or Higher Nm I) Motor Torque - Z Axis 6 Or Higher With Brake Nm J) Ball Screw - X,Y& Z Axes (Diameter X Pitch) 25 X 10 Or Higher Mm K) Ball Screw Finish - X, Y & Z Axes Ground And Hardened L) Ball Screw Class - X, Y & Z Axes Pre-Loaded With C3 Or Better M) Guide Ways - X, Y & Z Axes Antifriction Linear Motion Guide Way N) Guide Ways Size - X, Y & Z Axes 25 Or Higher Mm O) Guide Way Precision - X, Y, & Z Axes P Class , 4) Automatic Tool Changer A) Number Of Tool Pockets 8 Or Higher Nos B) Max Tool Diameter 80 Or Higher Mm C) Tool Selection Bi-Directional D) Tool Shank Type Bt30 E) Tool Weight Max 2.5 For Bt30 F) Tool Length Max 100 ~150 For Bt30 G) Tool Change Time (Chip To Chip) 5 Or Lower Sec H) Tool Clamp & Unclamp Disc Spring & Hydro-Pneumatic , 5) Accuracy As Per Iso 230-2 A) Positioning Accuracy For X,Y & Z Axes 0.012 Mm B) Repeatability For X,Y & Z Axes ±0.007 Mm C) Geometrical Alignment Iso 10791-Part 1 D) Accuracy Of Finish Test Piece Iso 10791-Part 7 , 6) Cnc System A) Control System - Fanuc B) Motors & Drives Compatible With Cnc Controllers As Mentioned Above C) System Resolution 0.001 Mm D) Tool Number Display On Machine Operator Panel E) Machine Control Panel Feed Rate, Spindle Speed Override Knob F) Mpg (Manual Pulse Generator) On Machine Operator Panel G) Cnc Features Graphic Simulation, Programming Help, Tool Offsets Mdi, Absolute/Incremental Positioning, Pitch Error Compensation , 7) Coolant/Lubrication A) Coolant Tank Capacity 100 Or Higher Litres B) Coolant Pump Motor 0.37 Kw C) Coolant Pump Output 20 Or Higher L Pm D) Lubrication Type Automatic Centralized Lubrication E) Lubrication Tank Capacity 3 Or Higher Liters , 8) Air Compressor For Tool Unclamp A) Compressor Type Screw Type With Dryer, Filter & Air Receiver B) Tank Capacity 200 Or Higher Liters C) Air Flow 10 Or Higher Cfm D) Pressure 7 Max. Bar , 9) Power Source A) Mains Supply (± 10 %) 415 V, 3 Ph., 50Hz B) Total Connected Load Requirement Approx. 15 Kva , 10) Standard Equipment A) Voltage Stabilizer 15 Kva B) Air Conditioning Unit For Electrical Cabinet As Required C) Backup Cd For Plc Ladder Logic 1 No. D) Machine Lightning 1 No. E) Levelling Pads And Jacking Screws 4 Nos. F) Operation Manual 1 No. G) Maintenance Manual 1 No. H) Installation Kit 1 No. I) Maintenance Tool Kit 1 No. J) 6 Rack Tool Trolley (Size 25X22X45) With Lock 1 No. H) Machine Guarding With Safety Compliance 1 No. , 11) Makes Of Critical Components A) Lm Guide Ways - Hiwin/Thk/Pmi/Star B) Ball Screws - Hiwin/Thk/Tsubaki/Pmi/Star/Hmt/Nsk C) Spindle Bearings - Rhp/Nsk/Fag/Skf/Nrb D) Atc - Pragati/Gifu E) Panel Ac - Werner Finley/Rittal/Lextecnoid F) Stabilizer - Neel/Se Rvomax/Consul/Farmax G) Lubrication - Cenlube/Dropco H) Coolant Pump - Rajamane/Gru Ndfos I) Cutting Tools And Holders - Sandvik/Taegutec/Ken Nametal/Seco/Mitsubishi J) Air Compressor (Capacity: 6 Kg/Cm2 - 300 Godrej/Elgi/Kaeser/Atlascopco L Pm Min.) , 12) Cutting Tools & Tool Holders (For Bt30 As Per Machine Supplied) A. Face Mill 45 Degree 63 Mm. Insert Type - 4 No. Suitable Inserts - 15 No. B. Face Mill Square Shoulder 50 Mm. Insert Type - 4No. Suitable Inserts - 15 No. C. Twist Drill Hss Straight Shank 6, 6.7, 8.5, 9.7 - 4 No. D. Spot Drill Carbide, Dia. 8 Mm X 90° - 4 No. Suitable Inserts - 60 No. E. Drill Insert Type - 16 Mm - 4 No. Suitable Inserts - 30 No. F. Solid Carbide Twist Drill Straight Shank - 8 Mm - 4 No. G. Solid Carbide End Mill Straight Shank - 10, 12 Mm Dia. - 4 No. H. End Mill Insert Type Straight Shank - 16 Mm Dia. - 4 No. Suitable Inserts - 30 No. I. Machine Taps Hss - M8, M10 - 4 No. J. Solid Carbide Reamer Straight Shank - 10 Mm - 4 No. K. Finish Boring Bar Dia. 20 To 25 Mm- 3 No. Suitable Inserts - 30 No L. Holder For Face Mills (Adapter) - 4 No. Suitable Incert - 60 Nos. M. Collets For Above Drills, Reamers, End Mills - 02 Sets N. Collet Holder Suitable For Collets - 4 No. O. Side Lock Holder For 16 Mm Insert Drill - 2 No. P. Machine Vice 0-150 Mm Range - Mechanical Type - 1 No. Q. C Spanner For Tightening Tools In Holder - 2 No. R. Magnetic Dial Stand - 2 No. S. Mallet - 02 No. T. Tap Wrench - 2 No. U. Hands Tools Set ( Spanners, Allen Keys, Etc.,) - 1 Box V. T Nuts, Strap Clamps, Clamping Nuts And Studs - 2 Set , Three / Four Door Refrigerator (Inverter Type) Specification - 300 Liter With Hc-600 A Gas. (1 Each) Make - Godrej / Whirlpool / Lg , Core Drill Machine Specification - Up To 2 To 2.5 Hammer Chiseling Bit 1500 Watt Make - Crompton / Power Hours / Bosch , Duct Able Split A/C Reciprocating Compressor Specification - Cap 1.5 Ton With R-22 Evapora(4 Copper) Make - Blue Star / Voltas / Daikin , Recovery Unit With Cylinders Specification - Cfc-Hfc,Hcfc, - 1 Each Cylinders Make - Trust Hal / Robin Air Rg-3 / Rishabh Enterprises , Decibel Meter 03 To 100 Db Make - Cadrim / Bosch / Generc , Descaling Pump Set With Stainless Steel Impeller And Accessories (1/2 Hp) Make - Bosch / Crompton / Robin Air , Fan Coil Unit With Water Valves Specification - 2 Way & 3 Way Valves (02 Ton) Make - Nutech Zeco / Blue Star / Voltas , Circulating Water Pump 0.5 Hp With Stainless Steel, Tank Capacity Inlet/Outlet Provision Make - Sharp / Lubi / Crompton , Water Cooler Storage Type Hfc-134A Specification - 200 Litter Reciprocating Compressor. Make - Blue Star /Voltas / Usha , Package A/C Air Cooled Type With Open Type Reciprocating Compressor Fins Type Condenser (05 Ton) Make - Blue Star / Voltas / Daikin , Bus A/C Tutorial Model Make - Estern Air / Tata Motors / Cool Ways. Ltd , Automatic Ice Coober Machine Specification - 5 Kg/Hr., Ice Cube - Material Stainless Steel Make - Godrej / Voltas / Blue Star , Walk In Cooler Puf Insulated Cold Room Specification - 01 Ton, 6X5X8 Foot, Cold Room Temp - 0 To 5° C Degree. Air Cooled Evaporator & Condenser Copper Tubing. Make - Unicool / Blue Star / Voltas , Shell Tube Type Dx Chiller Specification - 5 Ton Material - Copper Tubing Only Make - Voltas / Blue Star / Carrier
Contract Date: Ref. Documents Contract Value : Ref. Document
Trust & NGO No of Bidders 3
Maharashtra View Result →
Contract Date: Jun 30, 2026 Contract Value : 32,069
Boards / Undertakings / PSU No of Bidders 2
16.
Educational and Research Institute #10755196 Price Bid
Equipment Multimode Plate Reader , Supply Of Multimode Microplate Reader , Specifications For Multimode Microplate Reader General Wavelength Selectionshould Have Quadruple Monochromators. Should Have Two Excitation Monochromator And Two Emission Monochromator Forwavelength Selection. Detection Method Should Be Capable To Read Fluorescence, Time- Resolved Fluorescence, Luminescence And Uv-Visible Absorbance. Read Method Should Be Able To Perform End-Point, Kinetic, Spectral Scanning, Well-Area Scanning Assays. Microplate Typesshould Read 6, 12, 24, 48, 96 And 384-Well Plates Without Need For Any Adapters. Temperature Control Ambient +4°C To 45°C + 0.2°C At 37°C. It Should Also Have Condensation Control System To Minimize Condensation On Plate Lids During Incubation Process. The Incubation Should Be Through Natural Heat Convection To Prevent Edge Effects In Incubated Assays. Shaking It Should Have Linear, Orbital, Double Orbital Plate Shaking Modes. Also The Speed And Duration Should Be Programmable. Softwaresingle Integrated Windows Based Software For Reader Control And Data Analysis Should Be Supplied With The Instrument. The Software Should Be Able To Analyze The Data And Perform The Calculations. Software Must Have Quick Read Function To Enable Read The Plate Without Lengthy Protocol Definition. Automation It Should Be Upgradeable To Interface With Microplate Stacker And Also Compatible With Automated Co2 / O2 Incubator Upgradable It Should Be Upgradeable On Site To Include Anisotropy Integrated In The Same Instrument For Future Needs Absorbance Light Source Xenon Flash Lamp. Lamp Life Should Be At Least 1 Billion Flashes Wavelength Selection Monochromator Wavelength Range 230 - 999 Nm, 1 Nm Increment Bandpass4 Nm (230-285 M), 8 Nm (>285 M) Dynamic Range 0 - 4.0 Od Resolution0.0001 Od Pathlength Correctionpathlength Correction Facility Should Be Available As A Standard Feature. Monochromator Wavelength Accuracy +/- 2 Nm Monochromator Wavelength Repeatability +/- 0.2 Nm Od Accuracy< 1% At 2.0 Od Typical < 3% At 3.0 Od Typical Od Linearity < 1% From 0 To 3.0 Od Typical Od Repeatability< 0.5% At 2.0 Od Typical Stray Light 0.03% At 230 Nm Typical Reading Speed96: 11 Seconds 384: 22 Seconds Fluorescence Intensity Sensitivity Top: Fluorescein 2.5 Pm Typical (0.25 Fmol/Well 384-Well Plate) Bottom: Fluorescein 4 Pm Typical (0.4 Fmol/Well 384-Well Plate) Light Source Xenon Flash Lamp Wavelength Selection Double Grating Monochromators (Top And Bottom) Wavelength Range 250 – 900 Nm Dynamic Range 7 Decades ( 0 – 9,999,999 Rfu) Detection System Low Noise Pmt Gain Settingsshould Be Able To Program Auto Or Manual Gain Settings For Pmt Reading Speed 96: 11 Seconds; 384: 22 Seconds Time Resolved Fluorescence Light Source Xenon Flash Lamp Wavelength Range 250 – 900 Nm Sensitivity Europium 1200 Fm (120 Amol/Well In 384-Well Plate) Luminescence Sensitivity20 Amol Atp (Flash) 100 Amol Atp (Glow) Wavelength Range300 - 700 Nm Dynamic Range> 6 Decades ( 0 – 5,800,000 Rlu) Power Requirements Power100-240 Vac 50/60 Hz . 130 Watts Max Regulatory Regulatory Instrument Should Be Ce And Tuv Marked.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 1
17.
Housing Urban and Rular Development #10598781 Price Bid
Special Repair Of Electrical Installation & Fans & Replacement Of Main Panel, Dbs & Cables & Providing Acs, Dg Set At Office Of The Sub-Divisional Magistrate ( Kalkaji ) , 37-Institutional Area Tughlakabad, New Delhi-110062. ( Sh:-Supply Installation Testing And Commissioning Of 125 Kva Dg Set ) . , Sub Head - Dg Set Providing , Installing , Testing & Commissioning Of Silent Type Diesel Generating Set Having Prime Power Rating Of 125 Kva , 415 Volts At 1500 Rpm , 0 . 8 Lagging Power Factor At 415 V Suitable For 50 Hz , 3 Phase System & Consisting Of The Following: ( A ) Diesel Engine: Diesel Engine 4 Stroke Water Cooled , Electric Start , Of Suitable Bhp At 1500 Rpm Under Ntp Conditions Of Bs:5514 Capable Of Taking 10% Over Loading For One Hour After 12 Hours Of Continuous Operation . The Engine Will Be Fitted Complete With All The Required Accessories . ( B ) Engine Mounted Instrument Panel Fitted With Accessories & Indicators To Indicate Necessary Parameters And Having Digital Display As Per Standard Design Of The Manufacturer . I ) Start-Stop Switch Ii ) Water Temperature Indication Iii ) Lubrication Oil Pressure Indication Iv ) Battery Charging Indication V ) Rpm Indication Vi ) Over Speed Trip Indication Vii ) Low Lub . Oil Pressure Trip Indication Viii ) Engine Hours Indication Ix ) Kwh Meter ( To View The Record Of Total Unit Generated Upto Date ) . , ( C ) Alternator: Synchronous Alternator Rated At 125 Kva , 415 Volts At 1500 Rpm , 3 Phase , 50 Hz , Ac Supply With 0 . 8 Lagging Power Factor At 40 Degree C , 50% Rh At 1000 Mtr . Msl & At Ntp Conditions . The Alternator Shall Be Having Spdp Ip 23 Enclosure , Brushless , Continuous Duty , Self-Excited And Self-Regulated Through Avr Conforming To Bs:2613 . Suitable For Tropical Conditions And With Class-H Insulation . ( D ) Base Frame & Foundation: Both The Engine & Alternator Shall Be Mounted On Suitable Base Frame Made Of Ms Channel With Necessary Reinforcement Which Shall Be Installed On Suitable Cement Concrete Foundation & Vibration Isolation Arrangement As Per Recommendations Of Manufacturer . ( E ) Fuel Tank: Daily Service Fuel Tank Of 330 Liters Capacity Fabricated Out Of 3 Mm Thick M . S . Sheet Complete With All Standard Accessories & Fuel Piping Between Fuel Tank & Diesel Engine With Ms Class C Pipes Of Suitable Dia . Complete With Valves , Level Indications & Accessories As Required As Per Specifications . ( F ) Exhaust System: Dry Exhaust Mainfold With Hospital Silencer As Per Cpcb Norms . , ( G ) Starting-System: 12V / 24V Dc Starting System Comprising Of Starter Motors: Voltage Regulator And Arrangement For Initial Excitation Complete With Maintenance Free Batteries As Recommended By Manufacturer Of Dg Set & As Required As Per Specifications . ( H ) Acoustic & Weather Proof Enclosure With Arrangement For Fresh Air Intake For Cooling Of The Engine & Alternator , Extraction , Discharging Hot Air In To The Atmosphere As Per Specifications . , Fabricating , Installation , Testing & Commissioning Of Automatic Mains Failure Panel Fabricated In 2 Mm Thick Crca Sheet Steel With Suitable Size Ms Base Channel , Floor Mounted For Existing Dg Set Of 125 Kva , Including Manual Bypass For Both Main And Dg Set Supply Complete With Aluminium Bus Bars , Suitable For 125 Kva Silent Type Dg Set Complete With Relays , Timers , Set Of Cts For Metering & Protection & Energy Analyser To Indicate Current , Phase & Line Voltages , Frequency & Provision For Overload , Short Circuit , Restriction Earth Fault , Under Frequency , Connection With Existing Control Cabling Of Dg Set To Amf Panel , All Complete & Inter Locking Arrangement Including The Following . A ) 250 Amp 50 Ka 4 Pole Mccb - 2 Nos . B ) 250 Amp On Load 4 Pole Change Over Switch-2 Nos . C ) 250 Amp 4 Pole Power Contactor- 2 Nos . D ) Auto / Manual / Test / Off Selector Switch E ) 3 Nos . Of Current Transformer 250 / 5 Amps For Metering . F ) Energy Analyzer Unit To Indicate Current Voltage Frequency G ) Indicating Lamps For Load On Mains And Load On Dg Set . , H ) Sp Mcb For Instruments . I ) Control Unit With Three Impulse Automatic Engine Start / Stop And Failure To Start Lockout . J ) On / Off / Control Circuit With Indicator . K ) Audio / Video Annunciation For High Water Temperature Low Lubricating Oil Pressure Engine Over Speed Engine Fails To Start Amf Panel As Described Above , Providing And Laying In Position Cement Concrete 1:2:4 ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) In Foundation Of Pump , Dg Set Etc . Including Form Work Etc . As Required . , Earthing With G . I . Earth Plate 600 Mm X 600 Mm X 6 Mm Thick Including Accessories , And Providing Masonry Enclosure With Cover Plate Having Locking Arrangement And Watering Pipe Of 2 . 7 Meter Long Etc . With Charcoal / Coke And Salt As Required . , Providing & Fixing 25 Mm X 5 Mm G . I . Strip On Surface Or In Recess For Connections Etc . As Required . , Providing & Fixing 25 Mm X 5 Mm G . I . Strip In 40 Mm Dia G . I . Pipe From Earth Electrode Including Connection With G . I . Nut , Bolt , Spring , Washer Excavation And Re-Filling Etc . As Required . , Fabrication Supplying Installation Testing & Commissioning Of Cubical Feeder Pillar Panel Board , Dust , Damp And Vermin Proof , Compartmentalized Made Out Of 2 . 0 Mm Thick ( Ns ) Crca Sheet Duly Powder Coated , 300 Mm Deep Complete With 4 Strips Alu . Bus Bar Of 300Amps . Capacity Complete With Connection , Interconnections , Internal Wiring With Copper Conductor Cable Of Suitable Sizes , Earthing Etc . As Reqd . , Providing & Fixing Following Rating & Breaking Capacity And Pole Mccb With Thermomagnetic Release & Terminal Spreaders In Existing Cubicle Panel Board Including Drilling Holes In Cubicle Panel , Making Connections , Etc . As Required . , 100 A , 16 Ka , Tpmccb , 125 A , 16 Ka , Tpmccb , 250 A , 36 Ka , Fpmccb , Credit Item , Less Credit For Unserviceable 62 . 5 Kva Dg Set .
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
18.
Educational and Research Institute #10560896 Price Bid
Procurement And Commissioning Of Machineries , Equipments And Tools , Etc . In Laboratories And Workshop Related To Civil Engineering And Electrical Engineering Department Of Jangipur Government Polytechnic-1 Laboratory Vane Shear Apparatus [ Bis: 4434 ( 1978 ) ] 2 Soil Trimmer ( Hand Operated ) 3 Soil Extruder ( Hand Operated ) 4 Standard Penetration Test Set Apparatus With All Accessories Complete. 5 Ultrasonic Pulse Velocity Test Including Calibration Certificate 6 Profometer 7 Supplying Glass Apparatus For Environmental Laboratory As Specified In Details Specification. ( Borosilicate Glass Preferable ) Consolidated Rate For All Items Should Be Quoted. Individual Or Part Rate Will Not Be Considered. 8 Supplying Plastic Apparatus For Environmental Laboratory As Specified In Details Specification. Consolidated Rate For All Items Should Be Quoted. Individual Or Part Rate Will Not Be Considered. 9 Supply Of Reagents / Chemicals ( Merck Preferred ) As Specified In Details Specification.Consolidated Rate For All Items Should Be Quoted. Individual Or Part Rate Will Not Be Considered. 10 Standard Solutions ( Merck Preferred ) As Specified In Details Specification. Consolidated Rate For All Items Should Be Quoted. Individual Or Part Rate Will Not Be Considered. 11 Supply Of Filter Papers Of Mentioned Quantity / Amount As Specified In Details Specification. Consolidated Rate For All Items Should Be Quoted. Individual Or Part Rate Will Not Be Considered. 12 Cod Digestor 13 Double Distillation Unit 14 Desiccators 15 Aspirator Bottle 16 Evaporating Dish ( 150 Mm X 80 Mm ) 17 Magnetic Stirrer 18 Refrigerator 19 Multi Meter ( Digital ) For Measuring Water And Waste Water Quality Parameter 20 Variable Micropipette ( Eppendorf Or Equivalent ) 21 Digital / Gravimetric Air Volume Sampler 22 Bacteriological Testing System ( Mft Method ) 250Mm Diameter With Cover And Porcelain Plate 23 Instrument Set Up To Verify Kirchoff’S Current Law And Kirchoff’S Voltage Law. 24 Instrument Set Up For Measurement Of Inductance Of A Choke 25 Instrument Set Up For Measurement Of, Voltage Across Each Element Of R-L-C Series Circuit And Draw The Phasor Diagram To Calculate P.F 26 Instrument Set Up For Measure The Current , Voltage Across Each Element Of R-L-C Parallel Circuit And Draw The Phasor Diagram To Calculate P.F. 27 Instrument Set Up For Verify Conditions For Series And Parallel Resonance 28 Instrument Set Up To Verify Following Network Theorems Applicable To D.C. Circuit. I ) Superposition Theorem Ii ) Ii ) Thevenin’S Theorem To Verify Following Network Theorems Applicable To D.C. Circuit. I ) Superposition Theorem Ii ) Ii ) Thevenin’S Theorem 29 Instrument Set Up For To Verify Following Network Theorems Applicable To D.C. Circuit. I ) Norton’S Theorem Ii ) Maximum Power Transfer Theorem 30 Instrument Set Up To Study The Basics Of Pspice And Know The Important Commands. 31 Instrument Set Up To Plot The O.C.C. Of A D.C. Generator & Find The Critical Resistance. 32 Instrument Set Up To Find The Performance Of A D.C. Series Motor By Conducting Load Test & Draw The Load Characteristics. 33 Instrument Set Up To Find The Performance Of A D.C. Shunt Motor By Conducting Load Test & Draw The Load Characteristics. 34 Instrument Set Up To Compute The Efficiency Of A D.C. Motor By Swinburn’S Test. 35 Instrument Set Up To Control The Speed Of D.C. Shunt Motor Above & Below Normal Speed & Draw The Speed Characteristics. 36 Instrument Set Up To Determine Equivalent Circuit Parameters Of Single-Phase Transformer By Performing O.C. Test And S.C. Test. 37 Instrument Set Up To Determine The Regulation & Efficiency Of Single-Phase Transformer By Direct Loading Method. 38 Instrument Set Up To Operate Two Single-Phase Transformers In Parallel & Find Out The Load Sharing Between Them. 39 Instrument Set Up To Perform Heat Run Test Of A Single-Phase Transformer. 40 Instrument Set Up To Compute The Efficiency Of A Single-Phase Transformer By Back-To-Back Test. 41 3Phase Motor-Shunt Generator Set. Shunt Generator ( 230V, 15Kw, 1500Rpm, 4 To 8 Amp ) . Motor ( 440V, 32Amp 1450Rpm, 25Hp ) 42 Instrument Set Up For A ) To Measure Resistance, Voltage, Current, In A.C & D. C. Circuit Using Digital Multimeter. B ) To Measure A.C. Current By Clip-On Ammeter 43 Instrument Set Up For Measure Low Resistance By Kelvin’S Double Bridge. 44 Instrument Set Up For Measure Active And Reactive Power In Three Phase Balanced Load By Two Wattmeter Method And Observe The Effect Of Power Factor Variation On Wattmeter Reading. 45 Instrument Set Up For Calibrate Single Phase Energy Meter Using Resistive And Inductive Loads. 46 Instrument Set Up For Measure Energy Of Three Phase Balanced Load Using Electronic Energy Meter. 47 Instrument Set Up For Measurement Of Inductance By Maxwell’S Bridge. 48 Instrument Set Up For Measure An Unknown Capacitance By Schering Bridge. 49 Instrument Set Up For Measure Power Factor Of Single Phase And Three Phase Load By Pf Meter And Verify The Same Through I, V And P Measurement. 50 Instrument Set Up For Measure Current & Voltages By Low Range Ammeter & Voltmeter Respectively Using Ct And Pt 51 Instrument Set Up: A ) To Measure The Slip Of 3-Phase Induction Motor By – ( I ) Stroboscopic Method, ( Ii ) Tachometer. B ) To Reverse The Direction Of Rotation Of 3-Phase Induction Motor. 52 Instrument Set Up For Perform No-Load Test And Blocked-Rotor Test On 3-Phase Induction Motor & Draw The Equivalent Circuit From The Two Tests. 53 Instrument Set Up For Perform The Load Test On 3-Phase Induction Motor And To Study The Performance Characteristics Of The Motor. 54 Instrument Set Up To Control The Speed Of 3-Phase Induction Motor By– ( I ) Frequency Changing Method, 55 Instrument Set Up For Control The Speed Of 3-Phase Induction Motor By– ( Ii ) Pole Changing Method. 56 Tinstrument Set Up For Start A 3-Phase Slip-Ring Induction Motor By Rotor Resistance Starter And Determine The Effect Of The Rotor Resistance On The Torquespeed Curves Of An Induction Motor. 57 Instrument Set Up For Observe The Effect Of Excitation And Speed On Induced E.M. Of A 3-Phase Alternator And Plot The O.C.C. Of The Alternator. 58 Instrument Set Up For Find The Percentage Regulation Of 3-Phase Alternator By Synchronous Impedance Method At Various Power Factor And Load. 59 Instrument Set Up To Synchronise Two 3-Phase Alternator For Parallel Operation By A ) Three Lamp Method, B ) Synchroscope & To Study The Sharing Of Load Between The Alternators 60 Instrument Set Up For List And Explain Various Starting Methods Of 3-Phase Synchronous Motor And Applying Any One Of Them To Start The Synchronous Motor. Plot V-Curve & Inverted V-Curve Of The Same Motor. 61 Instrument Set Up For Study The Effect Of Capacitor On The Starting And Running Condition Of A Single-Phase Induction Motor, And To Determine The Method Of Reversing The Direction Of Rotation. 62 Instrument Set Up For Measure Linear Displacement By Lvdt & Plot Characteristics 63 Instrument Set Up For Measure Displacement By Strain Gauge & Plot Characteristics. 64 Instrument Set Up For Measure Temperature By Pt-100, Thermistor And Thermocouple Along With Simple Resistance Bridge. 65 Instrument Set Up For Plot Characteristics Of Potentiometer And Observe The Loading Effect On Output Of Potentiometer. 66 Instrument Set Up To Study The Following Signal Conditioning Circuits And Observe And Plot The Output ( I ) V To I Converter, ( Ii ) I To V Converter, ( Iii ) V To F Converter Using Op-Amp 741. 67 Instrument Set Up For Measure Angular Speed By Contact Type, Non- Contact Type Tachometer, Digital Tachometer, Proximity Sensor. 68 Instrument Set To Plot Fnrequency Response Of Active Filters ( Any Two ) :- I ) Low Pass Filter Ii ) High Pass Filter Iii ) Band Pass Filter Iv ) Band Stop Filters. 69 Instrument Set Up For Study The Principle Of Operation And Connection Of Pilot Devices Like – Push Button Switch, Limit Switch, Selector Switch, Pressure Switch, Float Switch. 70 Instrument Set Up For Measure Voltage, Current And Phase Difference And Frequency Using Cro. 71 Instrument Set Up For Study Open Loop Control Of Any Physical Control System And Study Of Closed Loop Control Of The Same System Using P, Pi And Pid Controller. 72 Instrument Set Up For Study The Position Control System Using Servomotor. 73 Instrument Set Up For Study The Operation Of An Instrumentation Amplifier Using Opamp. 74 Instrument Set Up For Demonstrate The Improvement Of P.F. Using Static Condenser. 75 Instrument Set Up For Demonstrate Various System Faults By D.C. Network Analyzer. 76 Instrument Set Up For Study Active And Reactive Power Flow Through Transmission Lines. 77 Instrument Set Up For Study Different Kinds Of Insulators ( Insulators Are Required To Be Available In Laboratory ) 78 Instrument Set Up For Study Pilc, Pvc, Frls And Xlpe Cables. ( Cables Are Required To Be Available In Laboratory ) 79 Instrument Set Up For Measure Solar Radiation With The Help Of Pyranometer. 80 Instrument Set Up For Fabricate An Op-Amp Integrator, Determine Its Amplitude, Phase Relation With Input, Duration Of Output Pulse Compared To Input For A Square Wave Input. 81 Instrument Set Up For Fabricate An Op-Amp Differentiator, Determine Its Amplitude, Phase Relation With Input Duration Of Output Pulse Compared To Input For A Triangular Input 82 Instrument Set Up For Identify The Terminals Of Thyristor And Plot V-I Characteristics Of Thyristor. 83 Instrument Set Up For Fabricate With Ic-555 - ( A ) Astable Multivibrator & To Determine Duration Of High Pulse, Low Pulse And Duty Cycle. ( B ) Monostable Multivibrator & To Determine The Duration Of High And Low Pulses Triggered Condition With Different R-C Values. ( C ) A Pulse Width Modulation Circuit To 84 Instrument Set Up For Study Fully Controlled Full Wave Rectifier Using Scr. 85 Instrument Set Up For Study Dc Chopper Circuit Using Scr. 86 Instrument Set Up For Study Series Inverter Using Scr. 87 Instrument Set Up For Perform Speed Control Of Dc Series Motor Using Scr. 88 Instrument Set Up For Study The Operation And Circuit Diagram Of Uninterrupted Power Supply Unit. 89 8051Microcontroller Kit 90 Instrument Set Up For Run & Test Program For The Following Using 8051 Microcontroller 91 Instrument Set Up For Demonstrate Hrc Fuse, Mcb & Elcb 92 Instrument Set Up For Identify The Components Of Circuit Breaker 93 Instrument Set Up For Plot The Inverse Characteristics Of Induction Type / Micrprocessor Based – ( I ) O / C Relay, ( Ii ) E / F Relay Using Relay Testing Kit. 94 Instrument Set Up For Differential Protection Of Transformer Using Transformer Differential Relay 95 D.O.L. Starter 96 Instrument Set Up For Test Directional Over Current Relay 97 Instrument Set Up For Determine Illumination Of A Surface 98 Instrument Set Up For Determine Candle Power 99 Instrument Set Up For Verify The Inverse Square Law Erify The Inverse Square Law 100 Instrument Set Up For Study Of Sodium Vapour Lamp, Mercury Vapour Lamp, Cfl 101 Instrument Set Up For Study Of Electric Arc Welding 102 Instrument Set Up For Study Of The Principle Of Induction Heating 103 Lux Meter
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 14
West Bengal View Result →
19.
Educational and Research Institute #10475490 Price Bid
Supply And Installation Of The Scientific Equipment Multimode Reader On Buy Back Terms , Items , Multimode Reader ( Including Buy Back Of Thermofishervarioskan Flash, Purchased In 15 / 02 / 2013 ) 1. Spectrophotometer Consists Of Uv / Vis Range 96 Well Multi Scan Microplate Reader For Easy To Use For Any Photometric Absorption Or Turbidimetric Research Applications Including Dna, Rna And Protein Analysis As Well As Fluorescence Studies. Moreover, Multi-User Environments For Kinetic, Spectral, And Endpoint Measurements Assays. 2. Measure Fluorescence Intensity ( Fi ) , Time-Resolved Fluorescence ( Trf ) , Absorbance And Luminescence In End Point, Kinetic And Spectral Measurements In The Uv / Vis / Nir Range From Appropriate Microplate Formats. 3. For Fluorescence: Excitation Wavelength Range 200 – 1000 Nm, Emission Wavelength Range 270 – 840 Nm, Excitation Bandwidth 5 Nm And 12 Nm, Emission Bandwidth 12 Nm, Or Better 4. Pc Control And Analysis Using A Software ( Software Should Be Compatible With Windows11, 64 Bit Os, Compatible Computer And Operating System Will Be Included Along With The Machine ) 5. Interface For Stand-Alone Use, And Includes Ready-Made Protocols For Fluorescence Studies, Uv Based Nucleic Acid And Protein Quantification As Well As Colorimetric Protein Quantification 6. 6 Well To 384 Well Format, Also Compatible With Low Volume ( 2-10?L ) Analysis Plate For Nucleic Acid And Protein Estimation 7. Light Source: Xenon Flash Lamp 8. Linear Measurement Range: 0 – 4 Abs ( 96-Well Plate ) At 450 Nm, ± 2%, 0 – 3 Abs ( 384-Well Plate ) At 450 Nm, ± 2% Or Better 9. Software Type: Open License Software ( Multi-Instrument Software ) Or With Full Licence 10. Accuracy ( Photometric ) : < 1?L With 50?L ( 0.4 Mm Tip ) , < 0.2 ?L With 5?L ( 0.25 Mm Tip ) Or Better 11. Incubator Temperature: Ambient + 4°C To 45°C Or Better 12. Shaking: Orbital 13. Measurement Speed: Reads A 96-Well Plate In 15 S, A 384-Well Plate In 45 S, And A 1536-Well Plate In 135 S ( Minimum Times ) ) Or Better 14. Software Language: English 15. Including 96 Well Plate 20 Numbers And 48 Well Plate 20 Numbers 16. Securely Store, Access, Share, And Manage Data 17. Compatible Computer And Accessories18. Warranty 3 Year 19. Including All Other Accessories To Complete Installation , Additional 2 Year Amc Should Be Quoted As Optional. ( Rate / Year )
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
20.
Heavy Industries and Public Enterprises #10390733 AOC
Vertical Extension & Other Development Works at Academic Block Annex-2 Palayad Campus, Kannur University, Kannur, Kerala under PM-USHA scheme- 1 Civil work -General Structural work 2 Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge25 mm average thickness 3 Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter 4 Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material with in 50 metres lead as per direction of Engineer -in-Charge. 5 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 6 Core Cutting of RCC slabs(12cm Maxi.thickness) by using mechanical core cutting equipment of required diameter of the pipe in full depth etc to the satisfaction of engineer in charge including all cost and conveyance materials and labours charge etc complete (dia 80-200mm) 7 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.All kinds of soil 8 Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work ( Payment shall be made on the cross sectional area of R.C.C. or R.B work) as per direction of Engineer-in-charge. 9 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil. and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m:Pipes, cables etc. exceeding 80 mm dia but not exceeding 300 mm dia 10 Excavation work by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soils as directed, within a lead of 50 m.Ordinary rock 11 Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 12 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) 13 Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 14 Making plinth protection 50 mm thick of cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth. 15 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work above plinth level upto floor V level 16 Extra for providing richer mixes at all floor levels. Note:- Excess/less cement over the specified cement content used is payable/ recoverable separately.Providing M-30 grade concrete instead of M-25 grade BMC/RMC. (Note:- Cement content considered in M-30 is @ 340 kg/cum). 17 Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 18 Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform 19 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers 20 Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts 21 Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases) 22 Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges 23 Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. 24 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more 25 Block work & Finishing Work 26 Laterate masonry with neatly dressed laterate stone of size 40x20x15cm or nearest size in cement mortar 1:6 for super structure above plinth level up to floor two level including all cost of materials, labour charges etc. 27 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) 28 6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand) 29 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer 30 12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) 31 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 32 Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats 33 Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) 34 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work 35 Add for plaster drip course / groove in plastered surface or moulding to R.C.C. projections. 36 Teracotta Clay Jali work, For Building work, minimum 7.5 cm thick as per approved design and pattern of Engineer in charge in super structure above plinth level upto floor V level with cement mortar 1:4 (1 cement : 4 coarse sand) with neat finish, polishing work all complete. 37 Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wallwith suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre.The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channelof 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG),plaster board conforming to IS : 2095 : (part 3) 1996 (Board with BIS Certification marks) 38 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 39 For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron) 40 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides 41 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness 42 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:125 mm 43 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- in- charge. 44 Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade, with necessary screws complete:300x10 mm 45 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. 46 Joinery 47 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross- section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 48 Providing and fixing to existing door frames.30 mm thick Fiberglass Reinforced Plastic (F.R.P) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF) / Polystyrene foam to be used all filler material throughout the hollow panel, casted monoolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS : 14856, complete as per direction of Engineer- in-charge. 49 Providing and fixing factory made uPVC white colour casement/casement cum fixedglazedwindowscomprisingofuPVCmulti-chamberedframe,sashand mullion(whereeverrequired)extrudedprofilesduly reinforcedwith1.60+/- 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriatedimension,EPDMgasket,stainlesssteel(SS304grade)friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mmsizeforfixingframetofinishedwall,plasticpackers,plasticcapsand necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately)Note: For uPVC frame, sash and mullion extruded profilesminus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Casement window double panels with S.S. friction hinges (350 x 19 x 1.9 mm) made of (big series) frame 67 x 60 mm & sash / mullion 67 x 80 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead/ double glazing bead of appropriate dimension. (Area of window above 1.50 sqm). 50 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness 51 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood 52 Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood 53 Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc 54 Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 55 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete:250x10 mm 56 Providing and fixing CP Brass Handle 450mm in all types of doors with the necessary fittings and arrangements all complete. 57 Providingand fixing chromium plated brass handles with necessary screws etc. complete:200 mm 58 Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality, with necessary screws etc complete as per direction of Engineer- in- charge. 59 French spirit polishing:Two or more coats on new works including a coat of wood filler 60 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.Using flats 30x6 mm for diagonal braces and central cross piece 61 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1800X2250 mm. 62 Fire Metal door. Material Specifications: Frame : GI 1.60 mm, Shutter : GI 1.20 mm, Shutter Width / Active Shutter Width : 808.00 mm, Frame Profile: 143.00 mm X 57.00 mm, Frame Profile type : Normal, Frame Rebate : Double, Door type : Single leaf door, Infill Material : Honey Comb, Vision Panel Active: 200 mmX300 mm. 8nos Ball bearing butt hinge, BB3090F, SS304, of size 100 x 75 x 3mm with screws in SSS , 1no Euro profile half cylinder 3005, 42mm Key x Blank, Silver satin finish , 2no Surface door closer TS73, size EN2/3/4, with standard arm, Silver finish, 1no Clear glass, 6mm of size 200 x 300mm, 2 nos concealed flush bolt, Mortise sash lock with lever handle on side and panic lever on other side. The door should have a minimum fire rating of 2hrs . Wall Opening Size 1000X2200 mm. 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge ( Door handle, lock and stopper etc to be paid separately) 64 Providing and fixing SS H handle having min 45 cm length in toughed glass door including all necessary screws etc. complete. 65 Providing and fixing of glass door SS Patch Lock with out handle in toughened glass door including all necessary screws etc. complete 66 Fixing 12 mm thick frameless toughened glass partition of approved brand and manufacture, including top & bottom fixing arrangement and making necessary holes etc. for fixing required fittings, all complete as per direction of Engineer-in- charge. 67 Providing and fixing 3M Fasara frosted etching film of thickness 25 microns self- adhesive of approved colour, shade, and quality with cutting as per approved design and pattern, including cleaning of glass and making surface smooth for fixing of film to the surface, all completed as per the direction of the engineer in charge. 68 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover 69 Providing and fixing ball bearing for rolling shutters. 70 Sanitary and CP Fittings 71 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litter low level white P.V.C.flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever require:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests 72 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 73 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizes respectively. 74 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 450x300 mm with single 15 mm C.P. brass pillar tap 75 Providing and fixing ceramic urinal partitions of standard size as per direction of Engineer-in Charge and of approved shade 76 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore 77 Providing and fixing uplasticised PVC connectionpipe with brass unions: 30 cm length15 mm nominal bore 78 Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:150 mm diameter 79 Providing and fixing C.P brass stop cock ( concealed) of standard design and of approved make conforming to IS: 893115 mm nominal bore 80 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore 81 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required:Kitchen sink without drain board610x510 mm bowl depth 200 mm 82 Providing and fixing white vitreous china laboratory sink with C.I brackets, C.P. brass chain with rubber plug 40 mm C.P brass waste and 40 mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required:Size 600x450x200 mm 83 Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in- charge. 84 Supplying and fixing CP Health faucet good quality including cost of materials and labour charges etc. complete as per the direction of site engineer-in-charge. 85 Flexible pipe32 mm dia 86 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with C.P. brass screws and washers complete. 87 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 88 Providing and fixing SS grating of approved quality and colour. Rectangular type with openable lid150 mm nominal size square 100 mm diameter of the inner hinged grating. 89 Providing and fixing disabled friendly bathroom kit with all accessories including wash closet with soft close seat cover and cistern with twin flush setting, wash basin of min dimensions 510mm x 400mm with all necessary fittings including Angle cock, Connection pipe, waste pipe, Spatula Lever basin mixer, Wall mounted 600mm long, Wall mounted grab bar 600 mm long and wall mounted hinged rail 750 x 750, Health Faucet with angle cock. Recommended Makes : CERA , Hindware, Jaguar or equivalent . 90 Plumbing 91 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall32 mm nominal outer dia pipes 92 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall40 mm nominal outer dia pipes 93 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer -in-Charge.Internal work - Exposed on wall50 mm nominal outer dia pipes 94 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.20 mm nominal outer dia pipes 95 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes& fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc.25 mm nominal outer dia pipes 96 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore 97 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mm nominal bore 98 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore 99 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore 100 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall 101 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall 102 Providing and fixing PVC pipes including fixing the pipe with clamps/ clip at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 6 Kgf/cm2 - External work - Exposed on wall 103 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow 104 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee 105 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63x50 mm dia Reducer 106 Supplying and fixing PVC Floor Trap 100mmx75mm size without Jali including cutting open, boring through RCC slabs and making good the damages. 107 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 32 mm pipe 6Kgf/cm2 108 Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 40 mm pipe 6Kgf/cm2 109 Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This included jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 75 mm dia 6Kgf/cm2 - External work- Exposed on wall 110 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Bend 111 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee 112 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75 mm dia Vent cowl 113 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap 114 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia 45 degree Elbow 115 Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall 116 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend 117 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee 118 Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl 119 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap 120 Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow 121 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :80 mm nominal bore 123 Providing and placing on terrace (at all floor levels) polyethylene water storage tank:ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 124 Yard Plumbing 125 Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2 126 Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling 127 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) with R.C.C. top with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix ( 1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size,) inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) finished with a floating coat of neat cement complete as per standard design:Inside size 120x90 cm and 90 cm deep including C.I. cover with frame ( medium duty ) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg ( weight of cover 58 kg and weight of frame 58 kg):With common burnt clay F.P.S ( non modular) bricks of class designation 7.5 128 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion Single pushfit Coupler110 mm 129 Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansionBend 87.50110 mm bend 130 Tile and Granite work 131 Providing and laying Matt Finished vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 1200 x 600 mm. 132 Providing and laying Matt finished Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, ofapproved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 1200x600 mm 133 Providing and laying Anti Skid matt vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. 134 Providing and laying premium vitrified bathroom wall tile in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete. 135 Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm 136 Marble work gang saw cut (polished and machine cut) of thickness 18 mm for wall lining ( veneer work), backing filled with a grout of 12 mm thick average in cement mortar 1:3 ( 1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 ( 1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade ( To be secured to the backing by means of cramps, which shall be paid for separately).Area of slab over 0.50 sqm 137 Providing and fixing 18 mm thick gang saw cut, mirror, polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Granite of any colour and shade. Area of slab over 0.50 sqm 138 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 139 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer -in-Charge.Granite work 140 Extra for providing opening or required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 141 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 142 Providing and fixing 12 mm thick gang saw cut, mat /rough finished granite, machine cut for steps, ramps or inclined plate form with raking and similar locations, of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 143 Structural steel 144 Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 145 Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 146 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 147 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes 148 Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 149 False ceiling 150 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with:12.5 mm thick tapered edge gypsum moisture resistant board 151 Providing and fixing tiled false ceiling of approved materials of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams per sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x 1.6 mm fixed to ceiling with 12.5mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85x 30x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T- sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer -in-charge.12.5 mm thick square edge PVC Laminated Gypsum Tile size 595x595 mm made of Gypsum plasterboard , manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyster film so as to make the tile a completely sealed unit. 152 Rainwater Harvesting ,Fire Tank,Septic Tank 153 Earth work in excavation by mechanical means (Hydraulic excavator )/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead up to 50 m and lift up to 1.5 m, disposed earth to be levelled and neatly dressed.Ordinary rock 154 Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.Ordinary or hard rock 155 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. 156 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size) 157 Providing and laying in position machine batched and machine mixed design mix M- 25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to siteof laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately.All work upto plinth level 158 Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more 159 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm 160 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 161 Supplying and fixing C.I with frame for manholes: 600mm x 600mm ( heavy duty) the weight of the cover and frame shall not be less than 208 kg 162 Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2 163 Providing and placing on terrace (at all floor levels) Stainless Steel 304as per IS 5522:1992 of capacity 5000 Litreswith suitable fixing arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. 164 Providing and fixing of Fire Rated door 1200x2100mm- Hollow metal fire doors at all levels from ISO 9001-2015 certified Manufacturer. Fire door should be as per NFPA 80 and NFPA 252. All fire doors should be tested at UL for 120 minutes and should pass both UL10B and UL10C. Doors shall be made from pressed galvanized steel confirming to IS277 as per following specification.Frame:Door frame shall be single rebate grooved profile of size 125 x 55 mm made out of 1.6 mm (16 gauge) minimum thick galvanized steel sheet. Frames shall be mitered and field assembled with self-tabs. Frames to have in build grooved sealing system and shall be site fitted with fire rated EPDM gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate ANSI UL labeled hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Frames shall be filled with fire rated puff and the gaps shall be sealed with silicon sealant.Shutter: Door leaf shall be 46 mm thick fully flush double skin door without vision lite. Door leaf shall be manufactured from 1.2 mm (18 gauge) minimum thick galvanized steel sheet.The infill material shall be resin bonded honeycomb core. All doors should be factory prepped for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers as per ANSI standard. For pair of doors integrated astragals has to be provided on the meeting stile for both active and inactive leaf.Door and frames shall be finished Pure Polyester Powder coated and shall have passed minimum 500 hours of salt spray test.Vision glass: The glass shall be 5mm clear fire rated glass of equal rating and not exceeding size of 114 sq. inches.Door Hardware: Stainless steel Ball bearing Hinges 3 Nos, Minimum 90Kg hydraulic surface applied rack and pinion door closers, Mortice Sash Lock with cylinder. One Side Handle and Other Side with 2 point Panic Bar. 165 Road Work 166 Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With Material conforming to Grade - I ( size range 75 mm to 0.075 mm) having CBR Value- 30 167 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-30 grade with approved color design and pattern. 168 Water proofing 169 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 170 Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) 171 Landscaping 172 Supplying of Flowering Shrubs (Heliconiya st. Vincent red, Ixora bush, Cana durf etc..) 173 Plantation of Trees, Shrubs, and Hedge at site i/c watering and removalof unsaverieable material?s as per direction of officer in charge (including cast of plant & water )Cost of plantation per trees plants (for 100 nos.=427.45/100) 174 Providing and Laying Landscaping of outdoor area with buffalo grass and small plants with all necessary levelling and filling as required. 175 Signage 176 Providing and fixing in position the signage board made out of 3 mm opaque PVC foam board of computerised cut, PVC non reflective self adhesive vinyl painted foam board of required size and colour. 177 Providing and fixing non lit Signages made of CNC Cut Stainless Steel projected letters and fixing it at site with all necessary fitting arrangements and accessories as per the design and requirement on instructions of the engineer in charge. 178 Furniture 179 Two tiered reagent racks (MS with powder coating) with granite top of 150 mm depth for side workbenches. The two tier should be placed at a minimum spacing of 300 mm. The item should be in compliance with IS 4209 (2013), NABL etc. The Length should be customized as per lab workbench and vertical posts must be placed at appropriate spacing. 180 Supply and Installation of Sink Module with SinkEach sink module should have a minimum dimension of 900 mm (L) x 900 mm (W) x 900 mm (H) and made of MS as per IS 1730 shall be designed with a single cabinet (with 2 shutter, SS304 hinges for easy and noiseless opening and closing mechanism). This module should include a sink made of 5 mm thick polypropylene with black color body. Minimum Dimension of the sink: 450 mm (L) x 600 mm (W). Sink should include PVC tap connection-15mm diameter (Goose neck type), grating etc. The sink module shall be portable and provided with 18mm thick granite table top (with cut out for providing sink). Item to be inclusive of all necessary fitting arrangement.The item should be in compliance with IS 4209 (2013), NABL, WHO etc. 181 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 750 mm D 182 Supplying and Fixing of Lab work Table with Granite Top supported over 18mm thick marine plywood , frame work with with GI members with Heavy Duty Levelers, minimum dimension of 2000mm L x 890mm D 183 Supply, Installation, Testing and Commissioning of Eye wash with Brass inject mould with epoxy powder coated body with auto released Valve and cup shaped water dispenser with min 1/2 HP power pressure booster pump 184 Counter Height Stools :Supply and erection of counter height stools ( bar stools ) of following specifications : Revolving adjustable Chrome plated steel body chairs with resistance to the corrosion. Cushion Seat with Lift mechanism for Adjustment of height. Minimum height 750mm before expansion. Medium Back rest and arm rest. Item shall be of reputed make. 185 Office Chair: Non-revolving executive chair with fixed armrest providing natural resting for arms. Seat with PU cutted foam backed fabric, back rest with mesh type fabric, Upholstery: Heavy duty rubber backed fabric in BLACK ( Size -55x60 cm) 186 Executive Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 187 Revolving Chair: Medium back ergonomic chair with five nos. star shaped Nylon base. Castor: 50mm diameter nylon twin wheel, gas lift height adjustment, back angle adjustment , Fixed armrest providing natural resting for arms. Seat with PU coated foam backed fabric, back rest with mesh type fabric, upholstery: Heavy duty rubber backed fabric in BLACK 188 Cabinet/Wardrobe: Providing and fixing Cabinet/Wardrobe unit with 18 mm thick Multi wood board with one side decorative and other side balancing lamination. cupboard shutters edge to be sealed with PVC edge bending tape 2.00 mm thick of approved brand including ISI marked nickel plated bright finishing M.S. piano hinges conforming to IS:3818 marked with fixing chromium plated brass 50 mm cupboard or wardrobe knobs, special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. Depth of shelves to be 300-600mm and shelves to be fix with proper support and bracket holders. as per layout drawing approved by Engineer in charge. Make laminate: Greenlam/ Merino / Century. Only front elevation will be measured. 189 Supply and erection of Airport type 3 seater waiting chair with powder coated chromium finish having minimum dimensions 1675mm length X 710mm width X 775mm total height and 400mm seat height . Seat: High quality cold rolled 1.2mm thick steel perforated sheet pressed and welded to form the shape. Arm & Leg: High quality 1.2mm thick MS Tube / Sheet . Cross bar: High quality cold rolled 2mm thick steel sheet pressed and welded to form the shape. 190 Table of size Min 2300x600mm Made of minimum 18mm BWR ISI (303 Grade) plywood (Century, Greenply, Fineply or equivalent). On top and all sides with 1mm thick hot press (3M or Henkel) laminates (Brand MERINO, Associates or equivalent) of approved colour and pattern as per the design. The table is provided with 1 drawer, 1 Storage, 1 key board locks, handles, mini fix, dowels and screws. Exposed edges to be finished with 0.8 mm edge band as per specified colour. 191 Supply of wooden table with one drawer and Cupboard unit made of hard wood varnishing/painting all complete. Size: 1200x600x750mm 192 Providing & supply of Conference Table with executive chair of 13 Pax with the following specifications.Table top size :3600 x 1200mm. Table Tops –made of 25mm thick MDF with waterfall top edges finished in PVC Membrane using unique wrap around technology for better aesthetics & long lasting use. Under structure – Legs made of 25 mm thick standard Black matt colour post formed panels interconnected with 18mm thick standard Black matt colour pre-laminated modesty panels, with height adjustable levelers to take care of uneven floors. Wire Management & Concealed wire management to take care of basic wiring requirements both horizontally & vertically. For closed configurations, liftable top cover, made of 12mm MDF finished in PVC Membrane, is provided to access the horizontal wire carrier. Vertical wire management is through flexible vertical wire manager, popup grommet with power & RJ45 Socket. Designed for Flexibility through modular Construction, PVC Membrane Finish Tops for seamless surface, Post formed Legs for safe use, Provision for easy wire management, Upgradeable / reconfigurable for future needs. 13 Nos Revolving adjustable type Medium height Back Office Chair with arm rest with back tilt and swivel mechanism constructed out of mild steel and high quality plastic. 193 Supply of wooded Chairs with armrest of Hard Wood Plank Seat and Reaper Back. 194 Supply of Wooden Bench and Desk made up of Mahagani of minimum size - Bench Size :1 83x30X46cm Desk Size :183x41x75 cm 195 Supply and installation of steel podium made of SS304 with min dimensions 500mm X 450 mm X 1200mm and having a sloped top surface, and having a decorative/ plain front face all made of SS 304 as per the design and approvals of the architect/ Engineer - In - Charge 196 Wiring-General Electrical work 197 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C 198 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 199 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2x1.5 sq.mm + 1x1.5 sq.mm earth wire 200 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 201 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 202 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 6 Sq.mm + 1 x 6 sq.mm earth wire 203 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 204 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire 205 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 2 X 16 sq. mm + 1 X 6 sq. mm earth wire 206 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 4 sq. mm + 2 X 4 sq. mm earth wire 207 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 208 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 209 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 210 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm 211 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 32 mm 212 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 213 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 214 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required. 215 Fixtures 216 Supply and Fixing suitable size modular GI box with cover in front on and providing and fixing 1 no RJ 45 including connections as required. 217 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 218 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 219 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet 220 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) 221 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet 222 Supply and Installation of surface/recess mounted LED 2x2 luminaire with CRCA housing suitable with fully diffused diffuser for general lighting. The luminaire should have CRI > 80 and CCT of both 6500K/5700K, Cool White Light. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3700 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 36 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro or equivalent 223 Supply, conveyance and Installation of compact, 2 feet,10-15W,LED tube light with high lumen giving soft glare free light including all required mounting accessories, frames complete. (Philips/WIPRO/Havells or equivalent) 224 Supply, Installation of surface mounted LED Tubelight. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 105 lumen/watt and Minimum system wattage of 30 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 25k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make - Philips, Crompton, Wipro, Havells 225 Supply, Installation of surface/recess mounted LED Round/Square luminaire with CRCA housing suitable with fully diffused diffuser for general lighting in office areas. The luminaire should have CRI > 80 and CCT of both 6500K/5700K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 3600 nominal lumens and efficacy of atleast 110 lumen/watt and Minimum system wattage of 10 -15 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours. The electronic driver used shall have a power factor >0.95 and THD. Make-Philips, Crompton, Wipro 226 Supply, conveyance and Installation of compact 10-15W LED Bulkhead Light giving soft glare free, Cool White light & complete with electronic driver including all required mounting accessories, frames, complete ( Make: Philips/WIPRO/Havells or equivalent) 227 Supply, Installation, Testing and Commissioning of 1400 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 228 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, ashers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. Make: Atomberg/Havells/ Orient Electric/ Crompton or equivalent 229 Supplying, conveyance and Installation of 150-250 mm sweep,1350 rpm, 3 - 5 blade BLDC Exhaust Fan including frames and all mounting accessories complete.Recommended Make: Atomberg Efficio/Crompton Brisk Air 230 Supplying, conveyance and Installation of BLDC Type Wall Fan having 3 blade, 400 mm sweep, Speed 1350 rpm, Air Delivery 70 CMM minimum, Wall Mount Fan including frames and all mounting accessories complete. Recommended Make: Atomberg Renesa/V-Guard ENVIRO WF BLDC/Havells Platina 231 Supply, Installation, Testing and Commissioning of 450 mm sweep, 900 rpm heavy duty exhaust fan with louver in existing opening including making good the hole to suite the size of above fan complete with connections using 3 core 1.5sqmm multi core pvc sheathed copper conductor cable etc as required. 232 SITC of skirting light fitting with white LED 3 module along with suitable size modular metal box with inner and outer plates with all accessories. 233 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). 234 Supplying & fixing suitable size Gl box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. lCD 235 Supply and installation of 2 Nos. 4 ft MS powder-coated hanging rods for tube lights, including supply and laying of 1.5 sqmm copper PVC insulated FRLS wire (3 runs: Phase, Neutral, Earth), necessary hardware (ceiling clamps, saddles, junction box, connectors), complete mounting, terminations, testing, and labour charges — complete in all respects. 236 Network and CCTV System 237 Supply of 16 ports Network Switch, Rack-mountable 10/100/1000 Mbps, Switching capacity 35.7 Mbps Features: Flow control, Layer 2 switching, auto-negotiation, auto- uplink (auto MDI/MDI-X), Weighted Round Robin (WRR) queuing, Quality of Service (QoS) Power: AC 120/230 V (50/60 Hz) complete. Make D-Link/TP Link/Cisco or equivalent 238 Supply Installation Testing and Commissioning of 32 channel embedded Linux NVR (Network Video Recorder), must connect 32 channel IP cameras, Should support min 2 SATA HDD and each should support Min 2TB and must record video simultaneously, (Recording Type: Continuous, Motion Detection, Alarm, Smart Event, Event Motion Detection, Alarm, Smart Event), Video Compression H.265(HEVC)/H.264+/H.264, 2 Year Warranty, Image quality should be maintained throughout the warranty period. Make: CP Plus/Hikivision/Dahua or equivalent 239 Network Switch for CCTV. 16 Port PoE Switch 1000BASE-T Copper Ethernet PoE+ connections, 10M/100M/1G RJ-45 copper ports, 1000BASE-X Fiber SFP ports, 16 port Auto sensing 10/100/1000 Mbps PoE, minimum CPU memory 512 MB with 2 SFP/combo ports, Energy Efficient Ethernet (IEEE 802.3az) Make: CP Plus/Netgear or equivalent 240 Supply, Conveyance and Installing of 2MP IP Dome/Bullet Camera having Progressive Scan True Day and Night Colour IR Camera having effective pixel of 2 MP, Video frame rate of 2MP @30FPS, Minimum illumination of 0.01 [email protected], 0 lux@IR On, 20 M IR Range, 24 IR LED, AWB, AGC, BLC, 2D Noise reduction, with 3.6mm board lense, 12 VDC, PoE IP67 rated weatherproof performance. 1 year warranty. Make: Bosch/CP Plus/Honeywell or equivalent 241 Supply and fixing of 6U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete 242 Supply Installation Testing & Commissioning of 16 Port Loaded Cat 6 - U/UTP Modular Toolless Patch Panel having a metal structure enabling them to be durably fixed to the uprights of the 19 chassis. Include rear cable manager to hold cables without need for cable ties. The termination of I/0s shall be without any manual crimping tools. 243 Supply and fixing of 4U wall mounting rack with supply and fixing of mounting brackets for support Lockable Front Door and Detachable Side Doors, Cable Manager and PDU of 4 or 6 sockets including cooling fan with accessories complete. 244 Supply and connecting 2 meter long CAT6 cable Patch cord having RJ45 connectors crimped at both ends, to the existing outlets as required. Make: D-Link/TP-Link or equivalent 245 Supply and Installation of LED Color display of minimum 32 inch screen, complete, UHD display Make: LG/Samsung/Panasonic or equivalent. 246 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable 247 Supply, Installation and Integration of Dual Band WiFi Access Point on false ceiling along with accessories, having Fast Wireless Speed, simultaneous 2.4GHz 300Mbps and 5GHz, 867Mbps Dual Band connections for 1.2Gbps of total available bandwidth, Superior Coverage of Four Fixed External antennas provide stable wireless connections and optimal coverage, App Control, Interface of 1× 10/100 Mbps WAN Port and 4× 10/100 Mbps LAN Ports having Working Modes (Router Mode / Access Point Mode). Make: TP-Link/Netgear/DLink or equivalent 248 UPS 249 Supply, Installation, Testing and Commissioning of True on-line Double Conversion 10 KVA UPS system with 3:3 Crest Factor Three Phase Input Three Phase Output. Inversion shall be Microprocessor controlled with instantaneous sine wave Control using IGBT. UPS shall have standard display features, alarms, safeties, etc Input Voltage range : a) Phase – Three Phase with ground b)Voltage range 190 VAC – 470 VAC c)Input Frequency :50/60 Hz d)Power Factor : 0.95 or above e)THD : less than 5% with full load Bypass f) Voltage Range – 200VAC – 240 VAC ) Frequency range – 45-55 Hz/55-65 Hz Output Voltage Range h)Voltage Range – 200VAC – 240 VAC i)Frequency range – 50/60 Hz j)Voltage distortion – linear load <= 2% k)Voltage distortion – nonlinear load <= 5% l)Output waveform – pure sinewave m) Crest Factor – 3:1 Minimum Back up time : Continuous 30 Minutes at full load Rectifier shall be Full wave Type (Shall fully meet the specified input power requirements) Battery Type: Sealed Lead Acid Maintenance Free DC Voltage : 96V DC System, Battery Nos and capacity shall be designed for optimum storage space. Installation &Commissioning Required Breakers also needs to be provided in input and output side for the UPS. Make: Liebert Vertiv/APC by Schneider/Numeric by Legrand 250 Cable Trays 251 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.375 mm width X 50 mm depth X 2.0 mm thickness 252 Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.150 mm width X 50 mm depth X 1.6 mm thickness 253 Fan Clamp 254 Providing and fixing 16 mm S.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. 255 DB and Switchgear 256 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) 257 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 258 Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) 259 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 260 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 261 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 262 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole 263 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 264 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 265 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps 266 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps 267 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 268 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 269 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole 270 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral 271 Earthing and Lightning Arrestor 272 Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re- filling etc. as required. 273 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 274 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 275 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 276 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 277 Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) 278 Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip, 125 mm long, with 4 nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required. 279 Laying copper/ G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 280 Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube,having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 281 Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 282 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) 283 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) 284 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.75 mm copper conductor (6 SWG) 285 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG) 286 Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) 287 Street Lights 288 Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 289 Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps 290 Water Purifier 291 Supply and Installation of Water Purifier having Multi-Stage Filtration: RO (Reverse Osmosis), UV (Ultraviolet), UF (Ultrafiltration), Storage Capacity: 7-9 Liters, Purification Features: RO: Removes dissolved impurities, heavy metals, and salts.UV: Kills bacteria, viruses, and other microorganisms. UF: Filters out fine particles and microorganisms. Mineral Booster: Adds essential minerals to enhance water taste.TDS Controller: Adjusts Total Dissolved Solids for taste preference. ActiveCopper: Infuses copper ions into the water for added health benefits.Aqua Taste Booster: Enhances the taste and maintains optimum pH level. In-Tank UV Disinfection: Keeps stored water pure.Smart Display/Indicators: Alerts for filter change, UV fail, water level, and service needs. Super Fine Sediment Filter: Removes fine and coarse particulate impurities. Water Level Indicator: Monitors the purified water level in the storage tank. Make: Aquaguard Aura 7L/ Bluestar Aristo 7L/Kent Grand Plus ZWW 9-Litre/ LG 8L 292 LT Cabling and Termination 293 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 294 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 295 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp 296 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 297 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp 298 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 240 sq mm 299 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm) 300 Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 400 sq mm 301 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 400 sq. mm (82mm) 302 LT Panels 303 Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work. General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall befl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 400A 3kA 4 Pole MCCB - 1no Ics = 100% Icu rating Digital Voltmeter 0- 500V with selector switch & Digital ammeter (0-400A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 400A. Out going : 250A ,50kA 4 Pole MCCB - 2no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 304 Lift panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 40A ,16-25kA TP MCB - 6 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list.Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 305 Sub Panel- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required. Incomer : 1) 63A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch &Digital ammeter (0-63A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 63A. Out going : 1) 32A ,16-25kA 4 Pole MCCB - 4 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 306 SSB2- Fabrication, Supply, Installation, Testing & Commissioning of floor mounted, cubical type, dust & vermin proof, powder coated of approved shade Electrical panel fabricated out of sheet steel not less than 2.0 mm thick. Wherever necessary, such sheet steel members shall be stiffened by angle iron frame work.General construction shall employ the principle of compartmentalization and segregation for each circuit. Unless otherwise approved, incomer and bus section panels or sections shall be separate and independent and shall not be mixed with sections required for feeders. Each section of the rear accessible type panel shall have hinged access doors at the rear. Overall height of the panel shall not exceed 2.4 meters. Operating levers, handle etc. of highest unit shall not be higher than 1.7 meters. Multi-tier mounting of feeder is permissible. The general arrangement for multi-tier construction shall be such that the horizontal tiers formed present a pleasing and aesthetic look. Cable entries for various feeders shall be either from top or bottom. Through cable alleys located in between two circuit sections, either in the rear or in the front of the panel. All cable terminations shall be through gland plates. There shall be separate gland plate for each cable entry so that there will not be dislocation of already wired circuits when new feeders are added. Cable entry plates shall therefore be sectionalized. The construction shall include necessary cable supports for clamping the cable in the cable alley or rear cable chamber. The bus bars shall be of aluminium of high conductivity electrolytic quality and of adequate section. All bus bars and connections shall be suitably sleeved / insulated in approved manner. All voltmeters and ammeters shall be fl ush mounted of size minimum 96 mm conforming to class 1.5 of IS 1248 for accuracy. All voltmeters shall be protected with MCB. On all the incomers of M.V panels, ON/OFF indicating LED lamps shall be provided and shall be suitable for operation on AC supply. Phase indicating LED lamps shall be associated with necessary ON/OFF toggle switch. All small wiring for Controls, Indication etc. shall be with suitable FRLS/ HFFR (halogen free fire retardant) copper conductor cables. Identification ferrules shall be used at both ends of the wires. The panel shall comprise of incomers, outgoing feeders and bus coupler as specified. The entire switch panel shall be cubical type generally conforming to IS 8623:1993 for factory assembled switch board. All incoming AIR CIRCUIT BREAKER/ MCCB shall have suitable adjustable tripping current and the time delay settings. The entire panel shall have a common earth bar of size as specified with two terminals for earth connections. The panel shall be suitable for operation on 415V, 3 phase, 50 Hz AC supply with enclosure protection class IP-42 as required.Incomer : 1) 250A 36kA 4 Pole MCCB - 1no Ics = 100% Icu rating, THERMAL MANGNETIC RELEASEDigital Voltmeter 0-500V with selector switch & Digital ammeter (0-250A) with selector switch and CTs etc. LED type RYB phase indication lamps, ON, OFF, Trip indication lamps, set of aluminium bus bar 250A. Out going : 1) 63A ,16-25kA 4 Pole MCCB - 8 no Ics = 100% Icu, (with Hylam sheet & warning signages as required) Switch gear make should as per approved make list. Panel shall meet all necessary specifications as per local electrical body/Inspectorate norms. 307 Transformer 308 Supply , Installation, Testing and commissioning of 500 kVA outdoor unitized substation with an 11kV/433V dry-type cast resin transformer and a 630A VCB typically includes a compact prefabricated design conforming to IEC62271-202 standards, offering IP53/IP23 protection, and featuring compartmentalized construction to prevent accidental entry into energized areas. The substation is designed to withstand electrical impulses, thermal, and dynamic stresses, ensuring reliable and robust performance with low power loss and noise levels. The installation involves placing the substation on a prepared concrete plinth, connecting high-tension (HT) and low-tension (LT) cables, and ensuring proper earthing and safety measures. The commissioning process includes testing the transformer, switchgear, and protection systems to verify operational integrity. Make: Unipower/Intrans/Voltamp 309 MSB and APFC Panel 310 Supplying, installation, testing & commissioning of cubical type MAIN SWITCH BOARD suitable for 415 V, 3 Phase, 4 Wire 50 Hz AC supply system having front surface area 6 sq.mtr (Approx.) fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having 630 Amp capacity extensible type TPN aluminium alloy bus bars of height conductivity, DMC / SMC bus bars of high conductivity, DMC/ SMC bus bar supports, with short circuit withstand capacity of 31 MVA for 1 Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25 mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of Al. bus bars and control wiring with sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears :- Interlocking:Electrical through advance contacts in MCCB/ ACB’s (incomers & bus couplers) and mechanical (castel key) interlocking should be provided to ensure that only one supply is available at a time on each section of bus and to eliminate any possibility of accidentally approaching two supplies at one bus section.Interlocking b(I) Incoming : 2 Nos 800 Amps (DG and MAINS) each four pole ACB of fault breaking capacity 50 KA (Ics=Icu upto 433 V manually operated, fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicators and frame earthing contact, conforming to IS 1397- 2 : 1993 as amended up-to-date complete with following accessories for each MCCB(a) Independent manual spring closing mechanism- 1 No.(b) Microprocessor release (EMI & EMC certified) for over current, earth fault & short circuit protection- 1 set.(c) Digital* type Voltmeter (0-500 V), with selector switch & back up HRC fuses/MCBs-1 set. (d) Digital* type Ammeter (0-.600 Amp), with selector switch and one set of 3 nos. CT’s of ratio. 800/5A Class I accuracy and 15 VA burden- 1set. (Ratio to be fi lled up).(e) 3 Nos. Phase indication LED lamps with 2 Amp back up HRC fuse, breaker ‘ON’ indicating light with 2 A HRC fuse, test terminal block set, fuses, circuits as per standard practice, auxiliary contacts for positive interlocking of the breakers as required.(f) Shunt trip coil 220 V A.C. (II) Bus Bars :TPN aluminium bus bars of minimum of 800 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bar cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 Sec (II) Outgoing :(1) (a) 4 Nos. 250 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 250/5 Amps Nos. (c) Digital* type ammeter (0- 400 Ap) with selector switch set. (2) (a) 1 Nos. 200 Amp4 Pole MCCB for (Ics = 35 kA upto 433 V) (b) CT’s of ratio 200/5 Amps set (c) Digital* type ammeter (0- 250 Amp) with selector switch set. (3) 3 Nos 160 Amp 4 Pole MCCB (Ics = 35 kA upto 433 V) (b) CT’s of ratio 160/5 Amps set (c) Digital* type ammeter (0- 200 Amp) with selector switch set. The switchgears/measuring instruments shall be as per the Choice of the Engineer in charge. The panel shall be mounted on required structural steel supports and frames for mounting, the price quoted shall be inclusive of the same. The panel shall have suitable provision for connecting to the incoming cables of 3R x 400 sqmm XLPE Aluminium cables and shall be provided with necessary earth leakage relays as per the Inspectorate Norms. The panel shall be as per the IS standards and shall conform to all norms of EB/Inspectorate/CEA. Make of Switchgear : ABB/L & T/Schneider Electric/Siemens/Legrand 311 Design, Manufacture, Supply, Installation, Testing and Commissioning of Automatic Power correction Panel having Incomer: 250A, TPN MCCB, Digital Multifunction meter for V,A,F,PF With CTs CL:1 with RYB Indication lamps-1 Set 250A Aluminium bus bar with heat shrinkable insulation sleeves-1 set, Intelligent power factor controller with control MCBs etc. complete The panel shall comprise of suitable combination of capacitor banks upto a total of 100 kVAR and shall be designed as per the standards of Electrical Inspectorate/CEA. 312 DG and AMF Panel 313 Supply, Installing, Testing and Commissioning of & Silent Type& Diesel Generating set having CPCB IV+ acoustic enclosure having Prime Power Rating of 500 KVA, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor and consisting of the followings: Diesel engine radiator cooled, electric start, of suitable BHP at 1500 RPM suitable for above output of alternator capable of taking 10% over loading for one hour after 12 hours of continuous operation. The engine will be fitted complete with all the required accessories. Engine mounted Instrument Panel fitted with and having digital display and necessary indication coupled to Synchronous alternator rated at 500 KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor. Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer. Daily service fuel tank of 440-460 litres capacity fabricated out of 3 mm thick M.S. sheet complete with all standard accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as required as per specifications. Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial excitation complete with suitable nos. of batteries (lead acid type) as required as per specifications. Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air in to the atmosphere as per specifications. 314 Design, Fabricating, Supply, Installing, Testing & Commissioning of automatic mains failure control including auto by-pass panel, suitable for 500 KVA silent type DG set complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor, KWH, KVARH & provision for overload, short circuit, restricted earth fault, under frequency, control cabling from AMF panel to diesel engine and elsewhere if required, all complete and inter locking including the following: (a) 1 Nos. 630 Amp., 50 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50-100% having adjustable OL & SC. Set at 350A (b) Auto/Manual/Test/Off selector switch (c) 2 Nos. over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay. (d) 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering(e) Energy analyser unit to indicate current voltage frequency power factor and KWH(f) Indicating lamps for load on mains and load on set(g) Fuse for instruments(h) Battery charger, complete with transformer/ rectifi er, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.(i) Main supply failure monitor(j) Supply failure timer(k) Restoration timer(l) Control unit with three impulse automatic engine start/stop and failure to start lockout.(m) Impulse counter with locking and reset facility.(n) ON/OFF/Control circuit switch with indicator(o) Audio/Video annunciation for(i) High water temperature(ii) Low lubricating oil pressure(iii) Engine over speed(iv) Engine fails to start(v) Full load/maximum load warning. AMF Panel shall be connected to Main Switch Board incomer with necessary interlocking arrangement to prevent simultaneous switching on of power supplies. All integration between Main Switchboard and AMF Panel is under contractor scope. 315 HT Cable 316 Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 300 sq mm 317 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm 318 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm 319 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Above 120 sq. mm and upto 400 sq. mm 320 Air Conditioning Works 321 Supply, Installation, testing and commissioning of 3 x 3 Cassette type Air Conditioner of following capacity and specifications: Consisting of ceiling-mounted type room unit (fan coil) with cordless remote control and one number outdoor condensing unit comprising of energy-efficient suitable rotary compressor for operation on single-phase, 230 V, 50Hz supply, fixing the outdoor unit on a raised platform as per manufacturers recommendation, with R-32/R-410A or equivalent refrigerant and fixing of room (fan coil) unit on ceiling, standard 5 m distance refrigerant copper piping with 13mm nitrile rubber insulation, providing and making interconnection between room & condenser as per site conditions, comprising of 1 dia drain PVC pipe with insulation up to 5 m, canvas connections, full electrical cabling from power plug near indoor unit and to outdoor unit, ODU MS stand, first charge refrigerant gas, suitable stabilizer etc complete as required. (Make: Voltas, Blue Star, Daikin, Hitachi, Carrier or equivalent). Minimum 2 TR 3 Star rated (inverter type AC) as per BEE 322 Supplying additional copper piping of required size and connecting the same to the available piping and extension of the same through 100mm PVC duct inside false ceiling. 323 Electrical Dismantling Works 324 Dismantling of existing outdoor transformer and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 325 Dismantling of existing DG set 100 kVA, AMF panel etc and handing over to client as required by stacking the same within the campus premises, including accessories complete as per direction of engineer-in-charge 326 Electrical Works- Fire 327 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm 328 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp 329 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 330 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp 331 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 332 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm) 333 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) 334 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 335 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 336 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 337 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 338 First Aid Hose reel &Wet Riser system 339 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.a.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585b.20 mm nominal internal dia gun metal globe valve & nozzle. c.Drum and brackets for fixing the equipmets on wall.d.Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.30 m 340 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 341 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way-100 mm dia M.S. Pipe 342 Supply and fixing of Air release valve SS body of 25 mm dia (UL Listed). 343 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 344 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 345 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 346 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 347 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 348 Hose Box - Supply, Installation, Testing and Commissioning of Hose Box -Double door - (cabinet) to accommodate Two pieces of 63 mm dia fire hose along with one pair of 63 mm dia male & female couplings and one branch pipe. The cabinet is made of MS sheet, painted in approved red colour with glass fronted hinged doors and lock &key (UL Listed). 349 Supply and Installation of Fire Brigade Draw-out Collecting head of CI Body having gunmetal 63mm dia instantaneous male draw out confirming to IS:903 suitable to fit on 100mm dia pipe with necessary flanges, rubber gasket, nut & bolts and other items. 350 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 351 Fire extinguishers 352 Supply &installation of ISI ABC type fire extinguisher of 4 kgs. Make SAFEX/ MINIMAX / CEASEFIRE or equivalent(UL Listed) 353 Supply &installation of CO2 type fire extinguisher of 4.5 kgs. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 354 Supply & installation of water mist type fire extinguisher of 9 liters. Make SAFEX / MINIMAX / CEASEFIRE or equivalent 355 Supplying & Installing of Clean agent based automatic modular fire extinguisher (ceiling mounted) suitable for A,B,C class fires & electrical fires, Capacity- 5Kg 356 Supplying & Installing of Mechanical Foam (Stored Pressure) Type fire extinguisher of 9L capacity with mounting clamp. ISI approved. Make : SAFEX/MINIMAX/CEASEFIRE or equivalent 357 Fire Pumps & Fire Panel 358 Electric driven Main Fire Pump: Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.1620 lpm at 56 m Head 359 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump)Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. 1620 lpm at 56 m Head 360 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump)a.Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.c. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. As required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 180 lpm at 56 m Head 361 Fabrication, supply, Installation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector switch & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING (Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.Jockey Pump63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROLControl for diesel engine comprising - Automatic/Manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitable for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller.Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 362 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 150mm 363 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 80mm 364 Supply and Installation of 12V DC, 200Ah maintenace free battery suitable for Diesel Engine driven fire pump operation with required connect cable set, battery stand. 365 Supplying & Installation of suitable flexible coupling/connection to fix at the suction and deliverys side of the fire pumps.dia 100mm 366 Signages 367 Supply and fixing in position Exit Signages photo luminescent type with indication arrows and letters Exit/Fire Exit/ Staircase/FIRE/Fire Station/Fire Fighting Equipment/Fire Duct/ Fire Extinguisher/ Floor/Fire Command Centre/Fire Pump Room/ No Smoking / Danger/ Call point / Sounder Identification Numbers (Ground/ 1st/2nd)/ In case of the fire do not use lift, use stairs and other mandatory signages recommended by Fire Departments having dimension 30 cm x 15 cm complete inculding fixing mechanism. 368 Supplying and Installing in position the signages approved by Kerala state fire service - of minimum size 1ft x 1.5ft made out of PVC rigid sheet 3mm thick with computer cut PVC non- reflective self adhesive imported vinyl painted on the front of PVC rigid sheet complete with wall mounting arrangements with mirror screws. with lettering- ASSEMBLY AREA 369 Signboards: Supply and Installation of Fire Escape Plan with fire fighting equipment location, exit in A3 Foam sheet with plastic lamination with necessory accessories to fix it on wall. 370 Supply and fixing in position & Fire Order& signage in suitable size made of high quality PVC foam sheet with photo luminescent lamination to make it glow automatically in the dark, with suitable arrangement to fix it on wall. 371 Supplying & fixing in position Assembly Point sigange in suitable size on aluminium composite panel with suitable stand to fix it on open area outside building. Assembly Point 372 Terrace pump 373 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump)a.Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520b. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.c. M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.d. Suitable cement concrete foundation duly plastered and with anti vibration pads. 450 lpm at 35 m Head 374 Design, Supply, Installation, Testing, and Commissioning of an Automatic Terrace Fire Pump Panel, including:- IP54-rated enclosure with powder-coated CRCA sheet steel.- 32A 16kA MCCB, 15 HP-rated pump 3P contactor, overload relay, and pressure switch for automatic pump operation.- Auto/Manual selector switch, START/STOP push buttons, hooter, timer, and protection features (dry-run, phase failure, etc.).- Indicators (Power ON, Pump Running, Fault, Low Pressure), meters (Voltmeter, Ammeter with selector switches).- Copper wiring, termination, and provision for cable glands.- Installation, onsite calibration, and full functional testing for pressure-based automation. 375 Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp 376 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) 377 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 378 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 379 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100mm dia 380 Pressure Guage-Supply, Installation, Testing and Commissioning of pressure guage, 4 & dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 381 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations (UL Listed).20 mm dia Make : Kartar/ Atom 382 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG) 383 Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required.10 sq mm 384 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 385 Above Ground Piping 386 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :100 mm dia 387 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :25 mm dia 388 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :80 mm dia 389 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :250 mm dia (wall thickness 6.3 mm) 390 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :150 mm dia 391 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :200 mm dia (wall thickness 6.3 mm) 392 Supply and Installation of 80mm dia M.S. &C& Class Diesel Engine exhaust pipe duly insulated with 50mm thick Glass wool with 1mm thick aluminium sheet cladding with bellows, flexible joint, necessary support, making hole in brick wall for pipe installation.Pipe dia 80mm 393 Underground piping 394 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 150 mm. Make - TATA / JINDAL 395 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (75 cm below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 200 mm. Make - TATA / JINDAL 396 Supply, Installation, Testing and Commissioning of MS C class ERW pipes with ISI Mark complete including cutting and jointing as per the requirements of standards, welding using high quality welding electrodes for pipe. supporting the pipes using Channels or Angles or structures at required intervals as specified for fire fighting work. Piping shall have one coat of anticorrossive zinc chromate industrial primer and two coats of IS approved colour code. All pipes are with ISI mark (IS 1239/3589)Pipes of required dimensions (length and dia) need to fabricated by the vendor by cutting/welding pipes of standard dimensions. length of each type( pipe diameter) should be fixed by the vendor after visiting the site and factory building. The pipe shall be laid direct in ground (1m below ground level) including excavation and refilling the trench and covering with 3 mm tar sheet. Pipe size 100 mm. Make - TATA / JINDAL 397 Valves, measuring devices & switches 398 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required:200mm dia 399 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required80 mm dia 400 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required100 mm dia 401 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required150 mm dia 402 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :80mm dia 403 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :150mm dia 404 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.150mm dia 405 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 406 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required 407 Pressure Gauge-Supply, Installation, Testing and Commissioning of pressure gauge, 4 dial, 0 - 200 psi range 3/8 BSP weather proof with stainless steel internals, siphon tube including fittings etc (UL Listed). Make: H Guru/Pointer 408 Supply and fixing of Air release valve Brass body of 25 mm dia (UL Listed) following IS standards, with required pressure rated. 409 Supply, installation, Testing and Commissioning of Lever operated Ball valves made of Cast iron conforms to IS 5312, at required locations.25 mm dia Make : Kartar/ Atom 410 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :100mm dia 411 MOEFA system, Automatic Detection & Fire Alarm System 412 Supplying, installing, testing and commissioning approved make Microprocessor based Multi-loop, Networkable Addressable Fire Alarm Control Panel with minimum 600 characters LCD display, 4000 trouble events including1000 alarm log history events, Self Programmable alphanumeric keypad for programming. The panel should be equipped with sufficient numbers of loops considering 20% spare capacity in each loop and shall be extendable upto 10 Loops. Each loop shall have a capacity of minimum 125 detectors & 125 other devices exculding 20% spare. The panel shall work in degrade mode in case of CPU failure, Products not having this feature may offer Redundant CPU. Four access levels, flash EPROM, 240 volts AC power supply, automatic battery charger, 24 volts sealed lead acid batteries sufficient for 24 hours normal working and 30 mins in alarm condition with the charging capacity of 200AH. The panel shall be capable of self programing without any dependancy on dongle or programming software. Quoted rate shall include supply of necessary software & hardware for progamming the panel with all necessary licence. Panel shall have Modbus over IP protocol for future integration with BMS. However, for present arrangement FA system will be standalone with 24x7 monitoring. The panel shall be capable of connecting to the cloud platform/solution. Complied to meet UL864, 10th Edition 6 Loop Networkable Addressable Fire Alarm Control Panel(Make: Honeywell or Equivalent) 413 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 414 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 415 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 416 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 417 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 418 Supplying, Installation, testing & commissioning of external power supply unit provides regulated and filtered 24 VDC power for hooter operation.Battery backup with built in charging. 419 CABLING & WIRING Supplying & laying of 2x1.5 sq mm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 420 Miscellaneous 421 Preparation of initial and final drawings, submission to Panchayath, Municipality, KSEB, Electrical Inspectorate, Kerala Water Authority, State Pollution Control board, Fire Department, Factories and Boilers and other agencies if any for getting approval, sanction and No Objection Certificate for building permit and completion from Fire Department and other department. Quoted rate shall be excluding statutory fee (All statutory fees shall be borne by Client-actual statutory fees shall be reimbursed on submission of original bill/challans from authorities).
Contract Date: Jul 17, 2025 Contract Value : 11.48 Crore
Boards / Undertakings / PSU No of Bidders 1
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
22.
Educational and Research Institute #10372706 Price Bid
Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Procurement Of Equipment Related To Laboratories And Workshops Of Mechanical Electrical Civil Chemical Engineering And Science Humanities Departments Of Hooghly Institute Of Technology Hooghly-Strain Gauge Trainer Kit - Gauge Factor : 2.1 Maximum Bearable Weight : 500 Gm, Cantilever Material : Stainless Steel, Bridge Configuration : Full Bridge Display : 3½ Or 4 Digit Ledwith User Manual 2 Measurement Of Temperature Using Thermocouple, Rtd, Thermistor, Ad950 - Transducers With Electronic Instrumentation Transducers : Thermocouple ( K - Type ) , Thermocouple ( J - Type ) , Thermistor ( Ntc ) , Rtd ( Pt 100 ) , Semiconductor Sensor ( Lm 335 ) And Semiconductor Sensor ( Ad 590 ) With User Manual 3 Bourdon Tube Type Pressure Gauge - Bourdon Tube Type Pressure Gauge, Pressure Range Upto 10, 000 Psi, Accuracy Upto + / -0.25%, With Pumping System 4 Flow Control System Using Mass Flow Meter, Single Loop Controller And Control Valve - Set Up Should Consist Of ---Mass Flow Meter, Single Loop Controller, Control Valve ( Glove ) , Transmitter Should Be Installed At The Upstream Of Control Valve, Controlling Facility By Controller, Continuous Water Recycling Facility, Table Mounted Set Up Preferable With User Manual 5 A / D & D / A Converter Trainer Kit - Analog To Digital Converter • 8-Bit Descrete Adc • On-Board Signal Generator With Adjustable Amplitude Levels • On-Board Led Bank To Observe Digital Outputs • Power Supply : +5V, ±12V Gnd • Interconnection Is Provided By 2Mm Connectors • Experimental Manual Digital To Analog Converter • 8-Bit Binary Weighted Resistors Dac • 8-Bit Ladder Type D To A Converter • Onboard Switches Are Provided For Digital Pattern Generation • 8-Bit Digital Inputs Ranges From 00 To Ff • Extensive Experimental Manual Is Provided With The Kit 6 8051 Based Advanced Microcontrollertrainer - 8051 Microcontroller Trainer Kit;Based On Intels 8051 Microcontroller 12Mhz With • On Board Power Supply • Rechargeable Ni-Cd Battery • Ascii Keyboard Interface • Programming Interface With Pc • Compiler And Cross Assemblers For Programming In C, • Lcd Display, 8051 Usb Programmer, 16*2 Lcd, Light Sensor Module ( Ldr ) , Tsop Sensor Module, 4*4 Matrix Keypad, Aa 6 Cell Holder, Burge Strip F-F Connectors, • 32 K Or Higheruser Ram. ( Expandable ) • Serial I / O Through 8251 Usart • Parallel I / O Lines Available Through Two 8255 Chips • 3 Channels Of 16 Bit Timer / Counters From 8253. 8254 • Adc & Dac Interface Module • Stepper Motor Interface • Square, Triangular, Staircase Wave Generator Interface Module • Dc Voltage, Current Measurement Interface Module • Zero Crossing Detectors Interface Module • Users’ Guide • Cd - Required Software, Usb Cable, Microcontroller & Its Interfacing Book With Application Projects, Cd - Required Software 7 Microcontroller Development Kit - 8051 Development Kit With Accessories And Software 8 Solar Photovoltaic Cell Characteristics Trainer Kit - 12V Solar Module With Suitable Arrangement Of Halogen Lamps 500W, Digital Dc Voltmeter And Ammeter, Lux Meter And Variable Resistive Loadwith User Manual 9 Flux Meter ( Magnetic ) - Integrating Type Digital Fluxmeter, With 3&Half Digit Digital Display, 4- Ranges Of Measurements Indicating Flux Values From 0.1 Kmt ( Kilo Maxwell Turns ) To 2*105 Kmt 10 Digital Storage Oscilloscope ( 70 Mhz ) Detailed Technical Specifications:- A ) No. Of Channels : 2 Or 4 B ) Bandwidth : 70 Mhz C ) Maximum Input : 400 V ( Peak ) D ) Sample Rate : 2 Gsa / Sec E ) Waveform Update Rate : 400 Waveforms / Sec F ) Memory Depth : 100 Kpts Standard ( Upgradable ) G ) Time Base : 5Nsec / Div. To 50 Sec. / Div H ) Waveform Update Rate: 50, 000 Waveforms / Sec I ) Display : 8.5 Inch Colour Wvga J ) Trigger Modes : Force, Edge, And Video, Pulse Width. K ) Built In Interface : Standard Usb 2.0 High Speed Device 11 Lcr Q Meter - Measuring Inductance ( L ) , Capacitance ( C ) , Resistance ( R ) , Quality Factor ( Q ) And Dissipation Factor ( D ) . With A Basic Accuracy Of 0.25% And Five Digit Display Resolution. 12 Diode And Zener Diode Characteristics Trainer - A Complete System To Study The Diode Characteristics Forward And Reverse Characteristics Experiment Can Be Performed On This Trainer Kit Silicon, Zener And Germanium Diode Are Provided With This System. Inbuilt Ammeter And Voltmeter. Digital Display For Displaying Voltage And Current. Different Test Points With User Manual 13 Experimental Kit For Input / Output Characteristics Of Bjt- One Fixed 12V Power Supply, One Variable Constant Voltage Source And One Constant Current Source For Output Characteristic Of The Transistor. Three Digital Meters On The Panel. One Fixed Frequency Of 1Khz With Variable Amplitude , Bread Board With User Manual 14 Training Kit To Study Of Opamp Characteristics - Specification: 2 No. Variable Dc Power Supply 0-3V / 30Ma, 1 No. Fixed Dc Power Supply 12V1 No. Operational Amplifier Ic 741 & Different Types Of Resistance, Capacitors And One Potentiometer With User Manual 15 Training Kit To Study Of Universal Logic Gates & Applications With Power Supply - • On Panel Gates : 4 Nand Gates ( 7400 ) , 4 Nor Gates ( 7402 ) , 4 And Gates ( 7408 ) , 4 Or Gates ( 7432 ) & 6 Not Gates ( 7404 ) • 5 Nos Of Extra 18 Pin Ic Base Mounted On Panel To Use Different Ics • 5 Logic Input Switches With Led • 5 Logic Output Led • On Panel 5 Sockets Each For +5 V & Gnd • Required Numbers Of Patch With User Manual 16 Training Kit For Study Of Kirchhoff’S Current & Voltage Law- Equipped With Necessary Resistors, Digital Voltmeters, Ammeter And Inbuilt Variable Power Supply 5V & 12V.On Board Test Points To Observe Signals, On Board Schematic Diagram, With User Manual 17 Analog Wattmeter - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Dynamometer Type Wattmeters I ) 5-10A, 150-300-600V, Ii ) 10-20A, 150-300-600V. 18 Series Parallel Resonance Of R-L-C Ckt - Kit For Series Parallel Resonance Of R-L-C Ckt: The Set-Up Consist Of Power Supply, Audio Oscillator With Digital Readout, Digital Rms Meters And Different Number Of Inductors ( Smoothly Variable ) , Capacitors, Potentiometer, Ammeter & Voltmeters With User Manual 19 Power Factor Meter ( Single Phase ) - Clear Rectangular Window With Excellent Visibility, Knife Edge Pointer And Anti Parallax Mirror. Accuracy Class ± 0.5% Of Full Scale Deflection. Power Factor Meter- Dynamometer Type Power Factor Meter , 1 Phase , Current Coil Range : 2.5 & 5.0 Amps. ( Dual Range ) , Pressure Coil Range: 150, 300 Volts ( Double Range ) . 20 Power Supply:Dc - • 2X30v-3A, 5V-3A • Constant Voltage & Constant Current Operation • Digital Displays For Voltage & Current • Adjustable Current Limiter • Protection Against Overload & Short Circuit 21 Training Kit For Verification Of A ) Superposition Theorem. B ) Thevenin’S Theorem. C ) Norton’S Theorem. D ) Maximum Power Transfer Theorem. Two Nos. Variable Dc Power Supply. Two Nos. Resistive Potentiometer ( Pot ) . Differnt Values Sets Of Resistances. Digital Dc Voltmeter, Dc Ammeter, Complete Operating Manual, Connecting Wires , Patch Cords, Etc. 22 Ac Distributor Simulator - Transmission Line Trainer Consist Of:- 100 Km X 3 Phase Tx Line Block At The End Of Each Block Short Is Possible All Digital Multifunctional Meters At The Sending & Receiving End, Loading Provision For Total 1Kva – Load Of Variable Separate Inductive, Capacitive & Resistive Load Bank. High Quality Patch Cord And User Manual. 23 Lux Meter - Sensitivity – 1 - 50, 000 Lux Error Percentage + 5%, 4 ½ Digit To 5 ½ Digit Detail Operating Manual Also To Be Supplied 24 Dielectric Strength Test Setup For Transformer Oil - Transformer Oil: Breakdown Voltage : 0-60Kv, Vertical Panel Mounted With Voltmeter, Glass Cover Encapsulated, Test Cup And Gap Measuring Gauge With 10 Liter Of Transformer Oil 25 Digital Insulation Tester , Digital Insulation Tester: 500V, 200Mohm, Portable Type 26 Half Wave & Full Wave Bridge Rectifier Trainer Kit, 1 / 2 Wave, Fullwave ( Centre Tapped & Bridge ) With Filter Ckt With User Manual 27 Experimental Kit For Characteristics Of Zener Diode, Complete Set Should Consist Of All Accessories To Perform The Experiment Using A Zener Diode Fitted On The Printed Boardwith User Manual 28 Experimental Kit For Input / Output Characteristics Of Bjt, Transistor Trainer Kit Consists Of One Fixed 12V Power Supply, Variable Constant Voltage Source And Constant Current Source For Output Characteristic Of The Transistor.Digital Meters On The Panelwith User Manual 29 Experimental Setup For Implementation Of Adder & Subtractor, With Adder ( Half & Full ) & Subtractor ( Half & Full ) Using Basic Gates. Must Have Onboard Input Supply, Display To Show Logic Outputwith User Manual 30 Complete Setup To Implement Encoder, Decoder , Multiplexer And De-Multiplexer With Power Supply, Display Unit, Patch Cords, Necessary Ic And Manuals For Each. 31 A / D & D / A Converter Trainer Kit 8 Bit With Accessories And Manual. 32 Scr Single Phase Half Wave, Full Wave, Fully Controlled Bridge Rectifier / Converter With In-Built Meters And On-Board Power Supplywith User Manual 33 Training Kit For Study Of Vi Characteristic Of Scr, Igbt , With Separate Section For Scr And Igbt Characteristics With In-Built Meters And Led Indicationswith User Manual 34 Scr Firing Circuit, Power Requirement: 230 Vac +10%, 50Hzstandard Accessories:6 Volt / 1 / 4 W Lamp, Patch Chords & Instruction Manual 35 Training Kit For Study Of Vi Characteristic Of Diac, With Proper Heat Sink And Training Manual.Consists Of One No. Diac With Proper Heat Sink.All Components Should Mount On A Screen Printed Pcb Fixed On Acabinets 36 Scr Commutation Circuit, Scr Commutation Circuit Commutation Techniques Used . I ) Class A Ii ) Class B Iii ) Class C Iv ) Class D V ) Class E Vi ) Class F • In Built Ic Based Dc Regulated Fixed Power Supply +12Vdc & Acwith User Manual 37 Electronic Energy Meter, A.C. Single Phase, 2 Wire Solid State ( Static ) Fully Electronic Energy Meter, Accuracy Class 1.0 & Current Rating 5-30 Amp. With Backlit Lcd Display For 240 Volt System Fitted With Pilfer Proof Meter Box. 38 Trainer Kit For Measurement Of Medium Resistance By Wheat Stone Bridgekit Must Have Inbuilt Power Supply, Measurement Range 1 Ohm – 100 Ohm, Having Sensitive Galvanometer With User Manual 39 Trainer Kit For Measurement Of Low Resistance By Kelvins Double Bridge, With Power Supply, Range 1 Microohm -1 Kiloohm, Having Sensitive Galvanometerwith User Manual 40 Earth Tester, Insulation Reslstance Test: More Than 25 Megohms At 500 V Dc Between Electrical Circuit & Containing Case, Display: Led Or Lcd. Dual Ranges: 0 - 10 - 1000 Ohm ( B ) 0 - 5 - 500 Ohm 41 Trainer Kit For Measurement Of Inductance By Anderson Bridgekit Must Have Built In Power Supply, Inbuilt Signal Source, Application Bridge On Screen Printed Front Panel Display, Set Of Unknown Inductance Coil, Variable Resistance, Set Of Capacitance, Audio Null Detector, Patch Cords, Connecting Wires And Head Phone, Complete Operating Manual. 42 Trainer Kit For Measurement Of Capacitance By Schering Bridge Kit Must Have Input Supply 50 Hz Sine Wave, Two Ratio Dial P & Q, Each Having 1, 10, 100, 100 Ohm Coil, 3 Decade Dial, X 0.001 Microfarad, 0.01 Microfarad, 0.1 Microfarad. Having Sensitive Head Phonewith User Manual 43 Tri-Vector Meter 3Ph 4 Wire Lt Ct & 3Ph 3 / 4 Wire Ht Ct / Pt Operated Fully Static Amr Compatible Tri-Vector Energy Meters Dlms Compliant – Category C 44 Trainer Kit For Measurement Oflinear Displacement Bylinear Variable Differential Transformer ( Lvdt ) For Linear Displacement, Type: Spring Loaded Core Type, Configuration: Axial Type Lvdt Full, Actual Displacement: By Micrometer Arrangement Pitch: 1 Mm, Circuit: Ac Excitation Source, Phase Detector & Digital Display, Excitation Source: Sine Wave Of 2 Khz To 5 Khz Variable Frequency And 0 To 5 Or 12V Variable Amplitude, Readout: Digital Display To Measure 0 To + / - 10 Mm, Indicating, Displacement In Millimeters With Core In / Out Indicated By + Sign, Test Points: Instruction Manual 45 Measure Pressure Using Pressure Sensor Kit.Resistive Pressure Transducer With Pressure Of 0-300Mm Hg / 6Psi, Primary Excitation Voltage Of 5V Dc On Board Provided. On-Board 41 / 2 Digital Panel Meter Provided Using Ad7135. Pressure Generation And Monitor Using A Pressure Gauge. Onboard Instrumentation Amplifier Provided With User Manual. 46 Trainer Kit For Op-Amp As Inverter, Non-Inverting Modefront Panel Built With High Class Insulated Printed Circuit Board Sheet With Well Printed Circuits And Symbols. Fuse For Short Circuit Protection. Patch Cords. The Trainer Is Housed In Abs Plastic / Wooden Cabinet.Size Of The Trainer Set 12”X8”. Instruction Manual. 47 Trainer Kit For Op-Amp As Adder, Differentiator And Integrator Instrument Comprises Of Two Dc Regulated Power Supply 0-5V Dc, ±15V Dc, One Meters To Measure Input And Output Voltage & Combination Of Resistance, Capacitors Mounted On Front Panelwith User Manual 48 Convert Digital Data Into Analog Data By Using Analog To Digital Converters And Analog Data Into Digital Data By Digital To Analog Converter Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden Box, Proper Patch Cord With User Mannual.Glass Epoxy Smobc Pcb, 8 No. Of Output Led, Wooden / Metal Enclosure 49 Simulate Differential Protection Scheme For Transformer With Power System Simulation Kit-3-Phase, 415V, 50Hz, Ac Supply. Control Supply : 1-Phase, 230V, 50Hz, Ac Supply. Short Circuit Protection : Hrc Fuses & Mcb. 3-Phase, 3Kva, 415 / 240V, Delta / Star Connected Transformer With Tapings Primary : 0-10-20-100% Secondary - 0-10-20-100% On Each Phase Of Windings, Natural Air Cooled. • Protection Cts : Primary Side Cts 10 / 1A, 5 Va, Cl-1, Wound Primary Typesecondary Side Cts 20 / 0.67A, 5Va, Wound Primary Type. • Fault Simulating Switches : 32A, 2-Pole, On / Off Rotary Switches Are Provided For Creating A ) Line To Ground Fault, B ) Line To Line Fault, C ) Inter-Turn Faultprotective Relays. % Differential Relay Static Type-With Minimum Basic Setting Biased Feature 10%, 20%, 30%, 40%, 50% Setting For Current. Ct Rated 1A Definite Time Over Current Relay • Earth Fault Relay • Aux. Supply To Relay : 110 / 220 V Ac / Dc Educational Bench Model With Schematic Diagram Of The Test Circuit Printed On The Model Test Points & Measurement Points Brought Out & Connected To Terminals, Circuit Setup For Testing Through Interconnections Of Patch Chords With User Manual 50 D.C. Compound Motor ( Open Type ) - 2 Hp- Dc Compound Motor: 2H.P. 1500Rpm, 230V, Open Type For Assemble And Dismantling Of Different Parts Of Stator And Rotor, Commutator, Brush Etc. 51 D. C. Shunt Generator- For O.C.C. Test-Dc Motor:- 2Hp, 1500 Rpm., 220V Dc Generator:- 1Kw, 1500 Rpm, 220V. Necessary Panel To Set Up With Foundation, Voltmeter:0-300V, Ammeter: 0-5A, Ammeter:0-1A, 4-Point Dc Starter. 52 Dc Motor Speed Control System With Power Supply & Motor-Motor 0.5 Hp, Variable Dc ( 0-230V ) Source, Built In Techogenerator, Digital Panel Meter, Power Circuits Of 4 Scrs ( 1200V., 25 A ) I.E. Half Bridge, Facilities Of Studying Torque Speed Characteristics Of Dc Motor, Torque Measurement, Rpm Indicatorwith User Manual 53 Swinburns Test To Compute Efficiency Of Shunt Generator, 1Hp, 220V, 1500Rpm-D.C. Motor:- 2 Hp, 230V, 1500Rpm, Shunt Field. Suitable Panel Withvoltmeter ( 0-300V ) , And Ammeter: 0-1A, Ammeter:0-5A With User Manual & Proper Setup With Foundation 54 Determination Of Equivalent Circuit Parameters Of A Single Phase Transformer By O.C And S.C Test- Transformer: 1 Kva, 230 / 115V, Variac: 0-270V, Panel With Voltmeter: ( 0-50V ) , Voltmeter ( 0-300V ) , Ammeter: 0 -2A, Ammeter:0-10A, Wattmeter: 0-1200W. 55 Compute The Efficiency Of A Single Phase Transformer By Back To Back Test- Complete Set Upwith User Manual: Ac Power Supply 0-230V At 4A ( Optional ) • Operated On Mains Power 230V, 50Hz +10% Digital / Analog Meters: • Voltmeter 2 Nos. ( For Primary And Secondary ) • Ammeter 2Nos. ( For Primary And Secondary ) • Digital Wattmeter 2Nos. 56 Parallel Operation Of Two Single Phase Transformers To Determine The Sharing Of Load Current, Apparent Power And Real Power- Transformer ( 2 Numbers ) : 1 Kva, 230 / 115V, Panel With Voltmeter ( 0-300V / 150V ) , Ammeter: 0-10A, Variable Resistive Load 115V, 10A, Single Phase. 57 Three Phase Transformer With Provision For The Connection In All Vector Groups ( Stardelta, Delta-Star Etc ) - 3-Phase, 1Kva, 415V / 230V, Transformer With Provision For The External Connection Terminals To Perform All Vector Groups ( Star-Delta, Delta-Star Etc. ) . 58 Isolation Transformer - Single Phase, 1Kva , 3Phase , 415V / 230V Isolation Transformer With Provision To Show Its Function And Testing Of It. 59 Tachometer For Speed Measurement-Digital Photo Tachometer • No Contact Rpm Measurement, Wide Measuring Range From 0.5 To 100, 000 Rpm. , Resolution: 0.1 Rpm ( < 1000 Rpm ) . • The Last Value Can Be Stored Into The Memory Automatically & Be Obtained By Pressing Memory Call Button With User Manual 60 4 Point Starter-For Operational Upto 7.5 Hp Dc Motor, 230Vdc. 61 Ac Variac ( Closed Type ) - Single Phase 8A, 0-270V, Rotary Type 62 Clip On Meter-Clip On ( Digital Led Display ) Type Meter Suitable For Measurement Of ( I ) Ac / Dc Current 5 / 10 / 50Amp, With Zero Set Button ( Ii ) Voltage:600Vac / 500Vdc, ( Iii ) Resistance: 0-10Mohms. 63 The Three Phase Squirrel Cage Induction Motor Setup With Various Starters- Complete Panel With Dol, Star-Delta , Auto-Transformer Starter With 2Hp , 3Phase, 415V , 4Pole, 1500Rpm, Squirrel Cage Induction Motor With Suitable Foundation & User Manual 64 Three Phase Squirrel Cage Induction Motor For Direct Load Test To Plot The Various Characteristics-2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 65 Three Phase Squirrel Cage Induction Motor For No Load And Blocked Rotor Test- 2Hp 3Ph , 415V, 4Pole , 1500Rpm Squirrel Cage Induction Motor With Necessary Panel With Meters , Starter With Suitable Loading Arrangements, Proper Foundation 66 Three Phase Squirrel Cage Induction Motor For Speed Control-Applicable Methods: I ) Auto-Transformer, Ii ) Vvvf. Specification: 2Hp , 3Hp , 415V, 4Pole, 1500 Rpm Three Phase Squirrel Cage Induction Motor With Necessary Panel Meters And Equipments. 67 Three Phase Slip Ring Induction Motor With Necessary Panel, Proper Base Foundation - To Measure The Open Circuit Voltage Ratio Of The Three Phase Slip Ring Induction Motor.Specification: 2Hp , 3Ph , 415V, 4Pole, 1500 Rpm 68 Three Phase Alternator For Oc, Sc And Load Test-3 Kva, 415 V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With Dc Motor ( Shunt ) 5Hp, 220 V, 1500Rpm, 4-Point Dc Starter, 3-Phase Variable Resistive Load 220 ( L-L ) , 15A Per Phase, With Necessary Panel, Proper Base Foundation 69 Squirrel Cage 1 Hp, 400V I / M & Stroboscope To Measure Slip- I ) 1Hp, 415V, 3-Ph, 50Hz, 1440 Rpm Squirrel Cage Induction Motor With Loading Arrangement. Ii ) Stroboscope For Frequency 0-6Khz. 70 Three Phase Synchronous Motor-Synchronous Motor:3Hp, 415V, 1500 Rpm, Excitor 220V, Dc Through Slipring, Dc Shunt Generator, 1.5Kw, Rpm, 230V Dc, Regulator Control With Necessary Panel, Proper Base Foundation 71 Synchronization Of 3 Phase Alternators By Synchroscope & 3 Lamp Method-Synchronization Of 3 Phase Alternators: 2- Numbers Of 3 Kva, 415V, 1500Rpm, 3-Ph, 50Hz, Alternator Coupled With 2-Numbers Of Dc Motors ( Shunt ) 5Hp, 230Vdc, 1500Rpm Alongwith Synchronisation Panel With Synchronoscope, 3-Lamps ( With Fuse ) For Lamp Method, Ammeters & Voltmeters For Dc Motors And Alternator, Digital Frequency Meter, Digital Rpm Meter For Dc Motors, 4-Point Dc Starters For Both Motors, 3-Phase Star Connected Variable Resistive Load, 4-Pole Mcb ( S ) & Variable Dc ( With 2-Pole Mcb ) Field Control For Both Alternators. The Whole Set-Up Needs To Be Equiped With Proper Electrical Protection, Base Foundation, Connector Cables, With User Manual, 72 Stepper Motor Controller Trainer-Stepper Motor Controller Trainer Stepper Motor : Motor Type :Unipolar, Torque : 6 Kg-Cm Phase Current : 0.8 Amp. , Stepping Angle : 1.8° / 0.9° Operating Voltage : 12 V Dc Input Pulse : 5V Ttl Compatible, Test Points :20 Gold Plated With User Manual 73 D.C. Servometer Speed Control -Trainer Kit-Kit For D.C. Servometer Speed Control- Position Control Of A 12V, 1A D.C.Gear Motor ( 50 Rpm ) Provision For Positive And Negative Tacho Generator Feedback Tacho Constant: 2V / 1000 Rpm Approximately Calibrated Dials For Reference And Output Position: Resolution 1° Servo-Potentiometers With Full 360°Rotation Microprocessor Based Waveform Capture / Display Card Built-In 3½Digit Dvm For Signal Measurements Built-In Step Signal And Ic Regulated Power Supplies For Electronic Circuits Separate Unit For Motor In A See-Through Cabinet 220V±10%, 50Hz Mains Operation With User Manual 74 Oil Hydraulic Circuit Trainer Unit: Hydraulic Circuit Trainer Unit Consisting Of Standard Components And Accessories For Carrying Out The Study Of Various Hydraulic Components And Hydraulic Circuits Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals 75 Pneumatic Trainer Kit With Compressor: Unit Is To Be Provided With Standard Mounting Board ( Modular Type ) With All Trainer Kits. All The Products Are To Be Provided With Suitable “One Touch Fittings / Push-In Fittings”.Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make , Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentionedalong With Delivery And Maintenance Kit & Manuals. 2 Hard Copies Of Operation Manual To Be Supplied; Installation, Demonstration And Training Of Faculties Are To Be Given. 76 Air Conditioning Trainer : Standard Specifications To Demonstrate The Basic Functioning Of Air-Conditioning. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manual. 77 Refrigeration Trainer: Standard Specifications To Demonstrate The Basic Functioning Of Vapour-Compression Cycle. Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned Along With Delivery And Maintenance Kit & Manuals. 78 Plug Gauge: Plug Gauge, Dimension: 25.4-0.5 Mm, Make: Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing Company. Brochure / Catalogue Showing Make, Model / Model No. And Also Online Link Of Brochure / Catalogue Should Be Mentioned. 79 Refrigerator 190 Lit, Direct-Cool Single Door Refrigerator 80 Analog Rough Balance 0-2 Kg, Pan Shape Rectangle Weight Display Analog 81 Analog Rough Balance 0-5 Kg, Pan Shape Rectangle Weight Display Analog 82 Borosil Burette Fitted With Boroflow, 100Ml 83 Borosil Burette Fitted With Boroflow, 50Ml 84 Borosil Burette Fitted With Boroflow, 25 Ml 85 Borosil 3.3 Glass Beaker With Graduation Marks, 1000Ml 86 Borosil 3.3 Glass Beaker With Graduation Marks, 500Ml 87 Borosil 3.3 Glass Beaker With Graduation Marks, 250 Ml 88 Spylx Burette Stand With Clampboss Head And Rod, Burette Stand With Clampboss Head And Rod 89 Transparent Borosilicate Glass Volumetric Flask, 250 Ml 90 Transparent Borosilicate Glassvolumetric Flask, 500 Ml 91 Borosilglass Rod , Outer Diameter: 7Mm, Length: 205 Mm, Material: Polished 3.3 Borosilicate Glass 92 Test Tube Holder, Material: Wrought Iron, Length: 200 Mm, Maximum Opening: 20 To 25 Mm 93 Spherometer: Minimum Length Of Leg 25 Millimeter, Minimum Diameter Of Leg 4 Millimeter, Pitch Of The Screw 1 Millimeter, High Grade Tool Steel 94 Instrument To Observe The Effects Of Frictions Using Inclined Plane: Consisting Of A Wooden Plane 90X18cm Having Adjustment For Setting The Required Angle Precisely Complete With Frictionless Pulley Linear And Circular Scale Pan A Wheeled Trolley And A Set Of Eight Slide Draws Having Bottom Of Different Materials.Base Board Very Superior Quality Having Thick Teak Wood Base, Fittedwith Glass Plate, Complete With Brass Arc, Leveling Screws Pan , Pulley And Iron N.P Roller Export Quality. Heavy Pattern. 95 Stainless Steel Led Digital Vernier Calliper: Mitutoyo, Made In Japan, Length 6, Vernier Constant 0.01Cm , Made Of Stainless Steel, Measure Internal, External And Height Dimensions , Digital Display 96 Verification Of Kirchoffs Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance -1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 20V, Number Of Led Indicators Available To Indicate Power Input -1, Availability Of Dc Voltmeter Available On Board -Yes, Range Of Dcvoltmeter - 0-30Volt, Availability Of Dc Ammeter On Board- Yes, Range Of Dc Ammeter - 0-50 Ma, Number Of Test Points Provided Onboard To Observe Signals - 14, Necessary Patch Cords Available For Interconnection - Yes, Casing Material - Plastic. Two Round Analog Meters For Voltage & Current Measurement, Components Are Mounted Behind The Panel With Printed Circuit Diagram, Connections Are Brought With 4 Mm Banana Sockets, Instrument Fitted In Highly Shockproof Plastics Box, 4 Mm Patch Cords Are Provided With The Trainer For Interconnections, Student Instruction Manual Will Be Provided With The Trainer Kit, 97 Instrument To Verify Inverse Square Law Of Radiation Using Photoelectric Effect: Type Of Display For On-Board Measurement- Digital, Availability Of Dc Voltmeter On Board - Yes, Range Of Dc Voltmeter - 0-20Volt, Availability Of Dc Ammeter On Board - Yes, Range Of Dc Ammeter - 0-100 Ma, Number Of Dc Regulated Power Supply With Short Circuit And Overload Protection-2, Voltage Range Of Continously Variable Dc Power Supply -20 Volt, Number Of Potentiometers Provided Onboard - 1, Number Of Test Points Provided In The Circuit To Observe Voltage And Current Signal - 5, On Board Schematic Diagram - Yes, Casing Material-Plastic, Number Of Led Indicators Available To Indicate Power Input - 1, Provision Of On-Board Knob For Adjusting The Voltage - Yes.Wooden Optical Bench, Photocell Housed With Red And Black Sockets, Lamp House With Lamps, Dc Microammeter. On Board Analog Moving Coil Meters , Galvanometer : 30-0-30, Selenium Photocell Mounted In The Metal Box With Metal Base, Lamp Holder With 60-Watt Bulb With Metal Base, Weight : 1.0Kg Approx.Standard Accessories : Selenium Photocell Mounted In The Metal Box, Wooden Plank With Half-Meter Scale Fitted On It, Lamp Holder With Lamp, Patch Chords, Instruction Manual, 98 Conversion Of Galvanometer Into Ammeter Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 99 Conversion Of Galvanometer Into Voltmeter Kit:Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance - 1, Number Of Variable Dc Power Supply Available On Board - 1, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board - Yes, Availability Of Dc Ammeter On Board-Yes, Necessary Patch Cords Available For Interconnection-Yes, Casing Material - Plastic.Instrument Comprises Of Dc Regulated Power Supply Of 0-5V. Three Round Moving Coil Meters ( One Voltmeter, One Milliammeter & One Galvanometer ) . Three Shunts, Three Resistances Are Mounted On Front Panel. 100 Ohms Law Kit: Type Of On-Board Meter Available -Analog, Number Of Potentiometers Provided Onboard To Vary Load Resistance- 1, Number Of Variable Dc Power Supply Available On Board- 1, Variable Dc Power Supply- 5 Volt, Number Of Led Indicators Available To Indicate Power Input - 1, Availability Of Dc Voltmeter Available On Board -Yes, Availability Of Dc Ammeter On Board - Yes, Casing Material - Plastic.Ohms Law App: To Verify The Ohms Law: Fitted With Slidingrheostat.Onedcvoltmeter, Mo.65&Onedcammetermo-65, Mounted On The Same Base With Terminals, 4 Mm Patch Cords Are Provided With The Trainer Kit For Interconnections 101 Pn Junction Diode Characteristics Kit: Compleate Set With Inbuilt Power Supply & With Digital Voltmeter & Ammeter Compatible For Both Forward & Reverse Bias 102 Boyles Law Apparatus: Burrete Graduated In Cc ( Or Ml ) With 1.0 Cc / Div. Scale Graduated On Both Sides ( Left & Right ) With Same Marking. Both Open And Closed Tubes Can Be Slided Up And Down Over Aluminium Rod. High Quality Synthetic Tube ( 1.0 M Long ) . One Spare Synthetic Tube. ( Withextra 500Gm Mercury ) . Superiorquality, Open&Closedtypeonemeterlongteakwoodboard Onheavy Metal Base Fitted With Leveling Screws Without Mercury But Complete With Pressure Rubber Tubing & Glass Tubes, Routinequality, Doublerodwithopen& Closedendtubes&Pressuretubing. 103 Instrument To Determine The Moment Of Inertia Of A Flywheel About Its Own Axis Of Rotation: Good Quality Stainless Steel Full Setup.Csi Superiorquality Flywheel With Weights , Comprising Of Carefully Machined And Balanced Cast Iron Wheel And Steel Spindle Is Supported On Ball Bearings In Strong Iron Brackets, Thickness: 4.4 Cm, Diameter :20 Cm, Wall Type With Pointer, With Revolution Counter, Set Ofslotted Weights For Flywheel Complete With Weights Cord And Hook. 104 Instrument For Determination Of Spring Constant Of Horizontal & Vertical Spiral Spring Setup: Stand With Heavy Base, Transparent Scale With Mm Resolution, Horizontal Support For Spring, Brightly Colored Stretch Indicator, Three Springs With Identical Diameter And Length, But Different Spring Constants, Three Of Each Spring Included, For A Total Of Nine Springs: Spring Constants Are 5 N / M, 8 N / M, 70 N / M.Consisting Of 45Cm Long Mirrorscale, Spring, Slotted Weights With Hanger And Pointer, Complete On Heavy Tripod Stand, On Metal Stand With Mirror Scale, Superior On Heavy Base, About 50 Cm High For Taking More Readings, Complete With Weights, Helical Spring: Light Spiral Spring With Pointer, Easy To Work With 50 Gm.Weight Complete With Hook For Hanging 105 Stainless Steel Led Digital Outside Micrometer: Mitutoyo: Made In Japan, 0.25Mm-0.01Mm, Least Count 0.01Mm, Made Of Stainless Steel, Digital Display. 106 Linear Expansion Coefficient Apparatus:- Superiorquality , Height 50 Cm, With Brass Rod, Stainlesssteel Finish A 50 Cm Long Expansion Base With A Built-In Dial Gauge And Thermistor.Three Metal Tubes — Brass, Copper ( 99.5%Cu, 0.5% Te ) , And Aluminum ( 98.9% Al, 0.7% Mg, 0.4% Si ) : 6.4 Mm Outside Diameter. A Foam Insulator To Avoid Heat Loss At The Thermistor Connection Point.Thermoplastic Elastometer Tubing With 6.4 Mm I.D.A Source Of Steam Or Hot Water, Such As The Pasco Model Td-8556A Steam Generator.A Digital Ohmmeter Such As Pasco Model Se9589 To Measure The Thermistor Resistance. Leads Should Have Banana Plug Connectors, Such As Pasco Model Se-9750 Or Se-9751 Patch Cords 107 Gclamp-4 Inchirwin 4 Inch / 100 Mm Record H / D G-Clamp T1204 108 Post Office Box-Post Office Box Of Material-Brass And Coil Manganin, Any Nationally Or Internationally Reputed Brand With Iso Certified Manufacturing 109 Muffle Furnace-Voltage ~230 V Ac, Insulating Maximum Temperatures 1000 C / 1200 C & Working Temperature 930 C / 1130 C Controlled By Digital Temperature Controller Cum Indicator 110 Digital Conductivity Meter-Electrode : Cell K = 1 – Pvc Sleeved Power Required: 230 V Ac 10%, 50 Hz, 5 Va Or 9 V Battery Standard Conductance: Conductance Of 1.000 M Stirrer Speed: 200 Rpm 111 Redwood Viscometer No.1-Material Stainless Steel Voltage 220 Volt Power Source Electric Frequency 50 Hz Phase Single Phase Accuracy + / - 3 °C Readability + / - 0. 5 Degree Capacity 50 Ml 112 Flash Point Apparatus With Stirrer-Voltage-115 V / 230 V, 50 Hz / 60 Hz Measuring Range- Up To 110 °C 113 Daniel Cell-Copper Vessel Complete With Porous Pot & Zinc Rod Diameter ~ 3.5- 4 Inch 114 Digital Voltmeter-Voltage -50-500 V Ac Accuracy ±10% 115 Arsenic Detection Kit-Reaction Time: 10 Minutes Test Type: Test Strip Colour Comparison Results Duration: Rapid 116 Digital Ph Meter-Resolution: 0.01 Ph Range: 0.0 To 14.0 Ph Temperature Controller Display 3 Digit 117 Cube Mould ( 70.6 Mm ) These Are Used For Casting Cement Mortar Test Specimens For Carrying Out Compressive Strength Test Of Cement As Per Is:516. These Moulds Are Manufactured As Per Is Specifications. The Faces Are Machined Flat Within ±0.02 Mm Tolerance And The Inside Dimensions Are Accurate Within ±0.2Mm. Each Mould Is Supplied With A Base Plate. Mould, Steel, For 70.6Mm Cube As Per Is: 10080-1982 Weight: Must Be 6.5 Kg Or More. Should Be Isi Mark. These Cube Moulds Are Made Of Steel. The Tolerance Between Faces Is Maintained At ±0.1 Mm And Plainness Is +0.03Mm. Cube Moulds Carry Isi Mark 118 Digital Rebound Hammer With Calibraton Anvil ( For Concrete Compressive Strength Analysis In The Field And Material Hardness Testing. ) Should Come With Rechargeable Batteries Including Charger. Capabality Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis. Should Conform To Astm C-805, En 12 504-2, Bs -1881- 202 And Other International Standards. Range:10 To 70N / Mm2 Impact Energy: 2.207 N-M Additionally The Following Minimum Specifications Must Be Met. Should Features 16 Character Digital Read Out And Provide Automatic Calculation Of Mean Rebound Number, Compressive Strength And The Median. Should Come With Rechargeable Batteries Including Charger. Capability Of On-Board Data Storage And Transfer To A Personal Computer For Further Analysis Is Required. The Necessary Software And The Required Cables For Connecting To The Computer Should Be Provided. A Calibration Anvil Should Be Provided 119 Ductility Testing Apparatus: Ductility Testing Machine Is: 1208 -1978 For Determining The Ductility Of Asphaltic Bitumen, Native Asphalt, Cut Back Bitumen And Blown Type Bitumen. It Consists Of Three Mould Assemblies On A Base Plate. A Separate Briquette Mould ( Total Length 75 ± 0.5 Mm, Distance Between Clips 30 ± 0.3 Mm, Width At Mount Of Slip 20 ± 0.2 Mm, Width At Minimum Cross Section 10 ± 0.1 Mm, Thickness Throughout 10 ± 0.1 Mm ) For Casting The Specimens Is Also Supplied. A Water Bath Of 10 Litres Capacity With A Perforated Shelf Not Less Than 50 Mm From The Bottom Of Bath And A Thermostat Controller For Heater. The Machine Has Two Standard Rates Of Travel Of 1 Cm / Mnt And 5 Cm / Mnt. The Movable Bracket Can Be Arrested Or Released Without Switching Off The Motor By A Clutch Arrangement. Suitable For Operation On 220V, 50 Hz, Single Phase Ac Supply. 120 Length Gauge Conforms To Is:2386 ( Part-I ) Used For Determination Of Elongation Index Of Aggregate. Length Gauge With Isi Certification Mark Is:2386 ( Part I ) , It Consists Of A Metal Plate On Which 8 Steel Pins Are Vertically Mounted With Specified Distances In Between. This Assembly Is Mounted On A Hardwood Base 121 Colorimeter ( Digital ) : Colorimeter, Equipped With Easy-To-Use Conventional Style Controls, Making It Ideal For Routine And Educational Use. Standard 10Mm Square Cuvettes, Semi-Micro Volume Cuvettes, Flowthrough Or Pour In / Suck Out Cells Can All Be Used With The Standard Sample Holder. Wavelength Range: 400 To 710Nm Wavelength Selection :: 8 In-Built Gelatin Filters: 430, 470, 490, 520, 540, 580, 600 And 710Nm Measurement Ranges:: 0-100%T, 0-1.50Abs, 0.1 To 1000 Concentration Bandwidth:Typically 40Nm Blank Drift:: 2% / Hr After 15 Minute Warm-Up Photometric Linearity :: 1%T Light Source :: Tungsten Filament Lamp Output:: Analogue, 10Mv Per Digit Power: 230V, 50Hz Size ( L X W X D ) :: 300 X 355 X 120Mm Weight:: 3Kg 122 Cod Test Apparatus: Cod Test Sample For Dry Bath Heating. Temperature 5+ 150 ◦C + / _ 1◦ C. Digital Controller With Heating Block. Sample Being Digested Within 2 Hours With Titration Method Bod Bottle Capacity : 300 Ml B.O.D. Incubators Has Been Designed Especially For Biological Oxygen Demand Determination & Other Applications Like General Incubators, Serum Studies & Enzyme Assays Test. We Can Also Customize The B.O.D. Incubators To Suit The Varied Requirement Of The Clients With In Stipulated Time Frame. Inner Chamber Made Of S.S.304 & Outer Chamber Made Of M. S. Powder Coated Full Length Inner Acrylic Door Permit Inspection Of Specimens Without Disturbing The Tem. Temp Controlled By Solid State Digital Controllers Housing All The Control With Pt-100 Sensor Illumination Light Are Provided For Viewing With Door Limit Switch. Cfc Free Hermetically Sealed Compressor Provide Temp. For Below Ambient Condition. Air Circulation Fan For Maintain Temp. Uniformity Throughout The Chamber. The Chamber Is Provided With Modular Removable Shelves Made Of S. S. For Complete Flexibility In Use. To Work On 230 Volts 50 H2. 123 Validation Protocols : Iq Oq & Pq Documentation With Calibration & Tradability Certificate Of Controller. Safety Features : Built In Temp Deviation Audio Visual Alarm, Safety Thermostat For Overshoot Temp. Cut Off System. Hrc Fuses For Compressor Heater & Mains Time Daily Circuit For Safety Of Compressor. This B.O.D. Incubator Is Available In Below Sizes: Size= 6Cu.Ft Inner Dimension W X D X H = ( 50 X 50 X 70 ) Cm Capacity= 175 Ltr No. Of Shelves= 2 124 Colony Counter: Working Temperature 5 To 50 ◦ C, 4 Digit Red Led Display, Petridish Holder, Fluorescent Lamp, Zero Reset Button, Dimension-30 ( W ) X33 ( D ) X10 ( H ) Cm, Net Weight 6.5 Kg. 125 Digital Nephelometer ( Turbidity Meter ) :Conformance:: Iso 7027 ( Ir Source ) Epa 180.1 ( Tungsten Lamp ) Measurement Range:: Auto-Ranging From 0 - 1000 Ntu Principle:: Nephelometric Non Ratio Accuracy:: + / - 2% Of Reading Plus 0.01 Ntu Resolution:: 0.01 Ntu ( 0 - 9.9 Ntu ) , 0.1 Ntu ( 10- 99 Ntu ) , 1 Ntu ( 100 - 1000Ntu ) . Response Time: < 6 Sec Display:Lcd , 3 Digit Light Source: Tungsten Filament Or Ir - Led ( 860Nm ) Power Supply: 120 - 240 Volts Ac Sample Cells: 30 M Shipping Dimensions :: 27.3X25.4X9.5Cm ( 10.7 X 10 X 3.75 ) Shipping Weight:: 1.92 Kg ( 2.9Lbs ) 126 High Volume Air Sampler: High Volume Sampler ( With Gaseous Attachment ) Technical Specifications :Flow Rate: - 0 To 1.8 M3 / Min Free Flowparticle Size: - Particles 0 To100 Microns & Below Collected On Filter Paper Holder. Spm Bigger Than 100 Microns Collected In A Separate Sampling Bottle Under The Cyclone. Sampling Time: - 24 Hours... 127 Low Volume Air Sampler: State Of The Art Microprocessor Electronics Flowrate And Volume Totalizations Displayed Are Temperature And Pressure ( 4 Options Available ) Classical Stp 0ºc, 760 Mmhg Normal T And P 20ºc, 760 Mmhg Modified Normal T And P 21.1ºc, 760 Mmhg Standard Ambient T And P 25ºc, 760 Mmhg Elapsed Time Meter Auto Zero Calibration Feature Of Flow Sensor Bright Led Display Flow Rate Accuracy Within ± 4% F.S. Rs-232 Communication Port W / Operator Selectable Download Frequency For Real-Time Data Auto Shut-Off On Time Or Volume 110 – 120 Vac, 50 / 60Hz; Single Phase 128 Hydraulic Bench: Top Tray: Size 1000 X 700 X 100 Mm ( Approx ) Water Circulation: 1 Hp Pump. Flow Measurement: Using Measuring Tank, Capacity 40L. Sump Tank: Capacity 100 Ltrs. Control Panel Comprises Of: Standard Make On / Off Switch, Mains Indicator, Etc The Whole Set-Up Is Well Designed And Arranged In A Good Quality Painted Structure 129 Crushing Value Test Apparatus: Consists Of M.S.Cylindrical Container 150 Mm ±0.5Mm Dia X 130Mm To 140Mm High With Base Plate 200 To 230 Mm. / Sqr X 6Mm Thick. A Plinger Of 148Mm ± 0.5Mm Dia X 100 To 115Mm High. Supplied Complete With Tamping Rod, 16Mm Dia X 600Mm Long, One End Rounded. And 1 No. Metal Measure 115 ± 0.5Mm Dia X 180 0.5Mm High. Consists Of Both End Open Cylinder, Base Plate, A Plunger 130 Digital Ph Meter: Measuring Range Resolution Accuracy Ph Range 0 To 14 Ph ( Min. ) 0.001 Ph ± 0.002 Ph Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Rel. Mv -1000.0 - 1000.0 ( Min. ) 0.1 Ph ± 0.2 Temperature Mtc -10.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Atc -5.0 - 100.0 °C ( Min. ) 0.1 °C ± 0.1 °C Temperature Compensation :Automatic And Manual Temperature Compensation Display : It Should Have Thin Film Transistor ( Tft ) Display Of More Than 4 Inch Color ( Blue / Red / Green / Yellow ) Display For Better Vision Of Readings With Clear And Well Arranged Icons Of Parameters Like Ph, Temperature, Mv, Date & Time Etc. Ingress Protection Level : It Should Be Ip54 Complied Protection Level. Power Requirements : It Should Be Operable With 9 -12V / 10W Dc Adapter.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 4
West Bengal View Result →
23.
Housing Urban and Rular Development #10200585 Price Bid
Tender For Construction Of New Muthalvar Padaippagam At Bhakthavachalam Park, Chennai; 1 Civil Works 2 Dismantling removing the existing Reinforced Cement Concrete work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 3 Dismantling removing the existing Brick work etc., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 4 Removing the existing ventilators,doors and windows including removal of frames ,hinges and fastenings arefully and stacking the same at site etc., complete. 5 Dismantling Floor finish and daddoing walls in cement mortar with mosaic tiles/glazed tiles/cuddapah slabs. 6 Carting away the surplus earth and debris to a lead of 5kgm.including Loading, unloading and dumping in the Corporation Land as directed during the execution. 7 Dismantling removing the existing closet, fitting, pipes, etc as per site., by using required mechinaries includingdisposal of unserviceable material, labour charges, as per direction of Engineer in charge. 8 Civil Works 9 Providing and constructing cast in situ hydraulic bored piles of specified diameter in M30 grade concrete using blended cement - slag cement with minimum cement content of 400kg/m³in accordance with the structural engineers drawings and directions, but exculding reinforcement including cost of mobalization of all necessary plants, equipments like piling rigs, temporary casing of appropriate length forsetting out cardinal points and the removal of the same, boring in overburden, using bentonite mud circulation technique or any other method dulythrough all strata upto the foundation level of piles etc., complete all as approved by the departmental engineer. Further include dewatering, placing concrete by tremie pipe method, disposal of bored material outside the site. Including Chipping carefully cut off portion of piles as required without any damage to the piles and dressing the top and removing all the debris away from the site with out any extra cost as directed including the cost of all tools, plants, conveyance, all labour, lead and lift required etc .,Conducting standard penetration test to identify the refusal strata for atleast 1 pile in group and atleast 25% of piles, comparing with refusal strata as indentified in soil report and providing socketting into refusal strata by 1.00mt or into hard rock by 100% dia of the pile. (Length of pile for payment shall be measured up to bottom of pile cap). 10 Boring or chiselling through any obstacles, boulders, weathered rock, etc. Upto founding level of piles for seating resting or socketting of files. The rate quoted shall include demobilising the site with all plants, equipment, piling rigs, necessary personnel brought for piling work, including removal and transportation of debrise away as directed, cleaning and reinstating site to original condition as acceptable by the Architect on completion of piling work. 11 450 mm Dia 12 Carrying out initial working pile load test on specified dia piles as specified in IS:291 1 (Part 4). Includes all plant, equipment, machinery. Instruments, measuring devices, platforms and kentledge pile caps etc., dismantling and carting away entire setup, excavation and dewatering etc., all complete 13 Earth work excavation for all foundations in all type of soils and sub soils to the required depth for Footings, plinth / grade beams, etc,. by mechinaries including manual excavation for the following type of soil / rock as per detailed specification. As per SS 20B as hard rock requiring blasting inclusive of shoring strutting and baling out water wherever necessary and including refilling 0 to 2.0m depth consolidation depositing the surplus earth in places shown clearing and leveling the site with an initial lead of 10 metre and lifts as specified hereunder etc., complete in all respects complying with relevant standard specification and as directed by the departmental officers. 14 Supplying and filling of Gravel / Good Earth by lorry in Foundation basement filling and site filling with approved materials excavation from approved quarries and compacted to meet requirement of table 300-1, 300-2 of MORTH, in layers not exceeding 300 mm loose thickness, spreading, breaking clods, removal of roots and other organic materials to the required line, grade and cross-section including watering, spreading by Dozer, grading by motor grader and consolidation by vibratory road roller with desired field density not less than 95% of maximum dry density ,including all lead,lift, loading, unloading, all labour, hire charges of all machineries, Transportation, etc., complete in accordance with MORTH technical specification clause No. 305 and with all other incidental charges and as per the direction of the Engineer-In-Charge. 15 Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive ofgiving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12to a depth of 8 in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc., 16 Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation. 17 Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth. 18 Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over. 19 Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12 to a depth of 8 around the building before laying the plinth projection.This holes has to be be closed after the treatment. 20 Supplying and Filling withM-sand in floor and others sub structures for 150mm thick and well watered, rammed and consolidated by power compacter. The rate includes the cost of river sand, compacting with mechanical compactors, labour charges for leveling, loading & Unloading and Transportation charges etc., complete and as per the standard specification. 21 Construction of Wet Mix Macadam 150mm compacted thickness in two layers by providing , laying , Paving , and compactingofaggregate gradation satisfying to Table 400-13 of MORTH and satisfying the physical paraeteres as per MORTH Table 400-12, mixing in a Wet Mix Plant of 200 tonne capacity at OMC , carriage of mied material to work site and laid in sensorpavers to the required line and grade as per the drawing and compacted with vibratory roller of 8-10 tonne to achieve the desired density of 98% of Maximum dry density and as per the direction of the Engineer-In-Charge of work. 22 Providing and laying plain cement concrete 1 : 4 : 8 ratio of(1 cement , 4 sand and8 graded stone aggregate 40mm nominal size) in foundation and basement for 100mm thick including dewatering wherever necessary and consolidation etc. The rate includes the cost of materials, labour charges, lifting charges, loading & Unloading and Transportation etc., complete and as per the standard specification. 23 Supplying and erecting centering for sides and soffits including supports and strutting up to 3.30 m height with all cross bracing for plane surfaces as detailed below, using mild steel sheets of 90 X 60 cm 10 gauge stiffened with MS angle of 25 X 25 X 3mm for boarding, laid over adjustable span & jacks and supported by 50mm dia pipes for general pipes scaffolding systems @ a spacing of 1.20m c/c and vertical connected at a height of 2.0m c/c including C & U clamps and base receiver cup at bottom for connecting pipes etc and removable systems etc., the rate including cost of all materials, labour charges, wastages, placing, transportation, lead & lifts, tools & plants, fuels, fixing in position at all levels, heights, masking tape in sheet joints, consumables, etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 24 For column footing plinth beam , pile cap staircase steps, piers raft beam raft slab etc., 25 For Plain surfaces such as RCC slab, Beam, Bed Block, waist slab, landing slab, lintel etc., 26 For square or rectangular column, boxing, sunshade etc., 27 Providing and Laying M 30 Standardised concrete Mix for all reinforced cement concrete with minimum cement content conform to IS 456-2000 using ordinary Portland cement of grade 53 from approved manufacturer, manufactured sand, 20 mm and down graded size coarse aggregates, necessary approved admixtures as per requirement. works for Footings, Grade beam, retainning wall drain wall & raft , Plinth beams, Column, Grade slab, Roof slab & beam, Column drops, Pergola, Staircase waist and landing slab lintel, Sunshades, parapet Cum drops, Steps, canopy, window boxing slab, Loft, fins facia Planter box, machine foundation, elevation features and other similar structures etc..excluding necessary centering, shuttering and reinforcement which shall be measured and paid separately under relevant items. in-charge The rate including cost of all designing the mix, batching plant, mechanical mixing, transporting and placing at all levels, leads, lifts, tools & plants, fuels, all materials, labour charges, wastages , laying, pumping the concrete to all levels, providing sleeves / openings in RCC slabs, compaction by vibrator, gunny bags for curing etc. as complete with all respects complying with relevant standard specification, as directed by theEngineer-in-charge 28 Basement 29 GF 30 FF 31 Terrace 32 Supplying, fabricating and fixing in position of steelFe 550 grade Reinforcement for all RCC work with Thermo Mechanically Treated Bars (TMT) conforming to IS 1786 of latest version according to drawings and binding the reinforcement with 18 gauge double fold GI binding wire and providing Concrete cover blocks to maintain the cover as required. The rate including cost of all materials, bending, tying grills, placing, transportation, lead & lifts, tools & plants, fuels, all materials, labour charges, wastages , laying at all levels, fixing in position, cost of cover blocks and GI binding wires etc. as complete with all respects complying with relevant standard specification, as directed by the Engineer-in-charge. 33 Brick work in cement mortar 1:6(one cement and four sand) using fly ash bricks of size 230mmx110mmx70mm for foundation and super structure as per detailed specifications and as directed by the departmental officers 34 Ground Floor 35 First Floor 36 Terrace 37 Brick partition walls of 11.50cm thickness using best quality Fly ashbricks of size 9 x 4-3/8 x 2-3/4(230x115x76) in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately) 38 Plastering 10 mm thick for ceiling including slabs, beams and column drops and staircase waist slab, sunshade, drops, chajjas etc.. with cement Mortar 1:3 (1 of Cement : 3 ofP sand) according to the specification. The Rate including Cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 39 Plastering of 12 mm thick for Internal walls with cement mortar 1:4 (1 of cement : 4 of fine P.sand)according to specifications. Rate shall include for providing GI mesh of nominal thickness at the junctions of masonry and concrete works to a width of 100 to 125mm including tying in position with suitable clamps/screws. Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 40 Plastering 12 mm thick for external surfaces with cement mortar 1:4 ratio (1 of cement : 4 of fine P.sand) including water proofing compound of “CICO No.1 or equivalent“ as per Manufacturers Specification with sponge finish (washed sand finish) all complete as per specification and as directed.Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading, preparation of surface, ncessary haccking in RCC surface, scaffolding, stagging, providing drip bands, moulds, grooves to any size and shape as shown in drawings tools and plants, fuel, curing,cleaning, consumables etc as complete with all respects complying with relevant standard specification and as directed by theEngineer-in-charge. 41 Supply and painting oftwo coats of Plastic emulsion paint of approved shade and colour over one coat of DCP Primer including one coat of Acrylic Wall Putty with DCP Primer.Rate including all brush, roller, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge.(Internal surface) 42 Supplying and painting of2 coats of weather proof exterior emulsion with high sheen, anti algal properties over one coat wall exterior primer of approved quality and shade etc., complete.Rate including all brush, ladder, scrapping, washing, materials, labour charges, wastages , cleaning, necessary lead and lifts, scaffolding, stagging, working at all levels, elevations,transportaion charges, loading, unloading, curing, sanding, touchup putty, surface thoroughly cleaned and wetted before painting as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 43 Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete (M-0652) 44 Supplying and filling the sunken slabarea byBRICK-BATCOBA by adding CICO NO:1 or approved equivalent admixture including applying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with water proofing compound like CICO No.1 at the rate specified in the manufacturers specification after entire completion of laying pipes, sanitary fittings etc.Rate including all materials, labour charges, wastages with necessary lead and lifts, working at all levels, protecting the laid pipes and sanitary fittings, finishing the surface smooth to receive the top coat of water proofing application etc. as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 45 i) Includingapplying two coats not less than 2 mm thick of TAPECRETE- AcrylicPolymer Based Waterproof Coating, over the plastered surface as including final coat of cement plaster 12 mm thick with cement sand mortar 1:3 mixed with approved water proofing compound like CICO No.1 or approved equivalent conforming to IS 2645 at the rate specified by the manufacturer over coated surfacepreparation of surface, finishing, curing etc. all complete at all levels as per manufacturers specifications and as directed. 46 Supplying and laying of Ceramic tiles of size 305 x 305 x 6mm for flooring approved make and quality with plain/colourwith base mortor in CM 1:3, 10mm thick and pointing with white cement by adding suitable colour pigments including finishing, jointing and polishing with neat finish etc., complete. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 47 Supplying and fixing Dadooing the wall with ceramic tiles of approved quality, colour and design joint free of size 600x300x10mm thick of approved make, in all floors over a base layer of cement mortar 1:2 (one cement: Two sand) 10mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge. 48 Providing and laying factory-manufactured linoleum flooring in the form of Rolls in the size of 12192mm of length and 1981mm of wide with 2mm thickness which laying above in the vertified tiles using the adhesive the flooring shall be laid over a smooth, level subfloor using manufacturer-recommended adhesives, complete in all respectsRoll flooring shall be laid with butt joints; edges shall be cold-welded or heat-welded for seamless joints.Apply a coat of linoleum polish or sealant after laying (if uncoated variant is used). Proper rolling to remove air pockets and ensure bonding the rate is inclusive of all necessary material, labour, transportation etc asper standards. 49 Finshing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in cement Mortar 1:3 (one cement and threee sand ) 12mm thick mixed with water proofing compound conforming ti ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed withred oxide and water proofing compound including curing et,. complete complying with standard specification and as directed by the departmental officers 50 Providing Polymer Coating (Water Proof Coating) for sunken portion of toilet with following specification and the surface shall be cleaned to remove all dust, foregin, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred thoroughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete. 51 Supply and laying with best quality the following materials of Machine Polished granite slab not less than 18 mm thick (Jet Balck) including cutting for wash basin and edge polishing to be set in CM 1:4 (1 of cement : 4 of manufactured sand) 20 mm thick including finishing the joints with white cement slurry, cutting, edge chamfering to approved shape and polishing rough, medium, nice and tin-oxide polish. The rate including cost of all materials, labour charges, wastages, necessary lead and lifts working at all levels, transportaion charges, loading & unloading, preparation of surface, ncessary haccking in RCC surface, cutting to required shape, edging, tools and plants, fuel, curing,cleaning, acid wash over finished surface, protection with Gypsum / Poplayeroverplastic sheet and removing the same before handing over as complete with all respects complying with relevant standard specification and as directed by the Engineer-in-charge 52 Supplying and fixing plywood partition with Teakwood frames of75x50mm size and with 3mm thick commercial plywood fixedwith screws and nails including fixing in position with 4Nos of iron hold fasts 50x6x230mm size etc.,complete.(ISI STD) 53 Supply & fixing of Tamilnadu Logo & Symbols as per design & Elevation. 54 Flooring with Joint free double charged vitrified tiles of approved quality, colour and design joint free of size 600 x 600 x 8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3 (one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40 kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officers. Rate including all materials, labour charges, wastages, necessary lead and lifts, working at all levels, transportaion charges, loading, unloading,the same before handing over as complete with all respects complying with relevant standard specification and as directed by theClient / Engineer-in-charge. 55 Supplying and fixing UPVC windows of casement type Open from the profile the size of outer frame 60mm x58mm and shutter profileare reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm. TheEPDM rubber covered with over all the edges of frame and shutter the shutter .will be provided with Espag multi power point locks and also it operates with Handle. The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be provided to the shutter and it should not allow leakege of water even at most ranging storms and should have key lockable action, security protective hinges , strong locking system and as per size for arresting noise and energyloss. The connecting mechanism between sash and windowshould be fixed to the wall with 100% packing with screws and silicon Packing all roundthe frames. The window should be got approved from the Executive Engineer before use on work. 56 Providing of 35mm thick factory made pre-laminated ABS(Acrolynitrile Butadiene Styrene) Door Shutter moulded indifferent designs, consisting of all round frame made out of water proof solid foam PVC bar of size 20 x32mm, reinforcedby 32 x 32mm - 2 Nos., for vertical made out of LVL(Laminated Veneer Lumber), core material of 32mm thickhigh density craft paper honey comb board, sandwiched onboth sides with pre-laminated ABS sheet thickness of 1.5mm.PVC edge banding of size 0.45mm on the vertical sides.Hardware made out of steel coated butterfly hinges - 3 Nos.,for each shutter and ISI make SS round lock complete forfinished item of work, complete complying with the standardspecification. The door shutter and frame should be gotapproved from the Executive Engineer before use on work. 57 FRP Door Sutter with FRP Door Frames along with vision panel (as per drawing) made out of FRP Sheets of 3mm thick of over all size 65mm x 50mm with rebate suitably reinforced using MS Angle / Flats, cost of holdfasts and Solid Core FRP Shutter Panel of 5mm thick and hollow core frames of 3m wall thickness for styles and rails etc., of sizes specified by Engineers. 58 Supplying and fixing UPVC Louvered Ventilators of from the profile the size of outer frame 60mm x58mm and shutter profile size of 60mm x 78mm both profile are reinforcement withGI/1mm125GSM and 100% Corrosion free,the profiles are multi Chambered sections with wall thick of 2mm.The EPDM rubber covered with over all the edges of frame and shutter . The Corners and joint should bewelded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thk should be providedin the Louvers.The window should be fixed tothe wall with 100% packing with screws and silicon packing all round the frames.The Ventilator should be got approved from the Executive Engineer before useon work. 59 FALSE CEILING WITH GYPSUM PLAIN TILES (600x600)Providing and fixing true horizontal level false ceiling using SAINT - GOBAIN GYPROC or Equivalent make with 24 mm Grid system using hot dipped galvanised Steel Section, exposed surface chemically cleaned caping prefinished in backed polyestar paint wall angle of size 24mmX24mm used in the periphery of the ceiling fixed to the wall partition R.C. Column bandwalls with the help of screws at 600mmc/c. Main runner of size 32X24mm suspended at 1200mm c/c max by using securely fixed to the structural soffit of R.C.C. slab by using 6mm Nylon Rawl plug at every 1200mm(Max) and 1200mm long Cross Tee of size 24X24mm to interlocked between Mainrunner at 600mm c/c (max) to form a grid of 1200mmX600mm. 600mm long Cross Tee of size 24X24mm is inserted to form a grid of 600mmX600mm and finally tiles laying with 12mm Gypsum plain Tiles as per stansdards 60 Providing & fixing of Brick Cladding in elevation as per drawing. The rate is inclusive of all necessary material , labour, transportation etc complete as per standards. 61 Supplying and Fixing of aluminium Dye Cast Letters of approved size and colour treatment processis achieved with MRF colour coat and then the processed coloured layer is set into the kiln for the heat treatment process for the following sizes aluminium Dye Cast Letters 6 Size. Tamil Stainless Steel Letters 25CM 62 Supplying and fixing M.S.Grill gate of required size in two shutters with necessary iron members, gun metal cups and wheels 75mm dia. with fittings locking arrangements,etc., complete,including painting a priming coat of approved primer,etc., complete (The design of gate furnished is subject to alteration during execution.) 63 Supplying and Painting the wall with Texture Finish Paint including thorough scraping, clean removal of dirt, Primer. The rate includes cost of materials, brushes, sand paper, rollers, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) 64 GYPBOARD DOUBLE SKIN PARTITIONProviding and fixing of Gypsum Dry wall Double skin partition of 75 mm thick using SAINT - GOBAIN GYPROC or Equivalent make and the partition shall be of one layers of tapered edge 12.5mm thk Gyp board screw fixed with dry wall screw of 25mm at 300mm c/c to either side of 48mm studs. GI steel sections to be placed at 610 mm c/c in 50mm floor and ceiling channel 0.55mm thick having equal flanges of 32mm made of GI steel with joints staggered to avoid leakage through joints. Finally square and tapered edges of the boards are to be finished so as to have a flush look which includes filling and finishing with jointing compound, joint paper and 2 coats of Drywall top Coat suitable for Gypsum upto primer level.As per India Gypsum Specs.Note: Angle Bead to be used at external angles to get straight line finish & protection from normal impacts. 65 Providing and laying water proofing treatment to vertical and surfaces for sunken portion of depressed portions of W.C., and the like consisting of :i) 1st course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) 2nd course of 20mm cement plaster 1:2 (1 Cement : 2 Coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) 3rd course of applying blown or residual bitumen applied hot at 1.7Kg per sqm of area. iv) 4th course of 400 micron thick PVC Sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm) 66 PLUMBING WORKS 67 Supply,erection and testing & commisioning of 3HP Submersible pumpset in the capacity of 6000 LPH @ 300Ft, max. total head of 350 Ft pumps fitted with bronze impellers and having delivery size of 40mm - 430V along with 3mts cable and manufactures standard control panel which is mandatory and as directed by the officer incharge.( Sump to OHT transfer pump) 68 Labour charges for the erection of submersible pumpset in borewell/openwell including fixingand jointing submersible cable with proper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, Voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 69 Drilling of 6 dia vertical borewell so as to have a finished size of 6 dia borewell in boulder area to any required depth as decided by theincluding Transportation from one place to anothr place with in Tamilnadu State by direct or reverse rotary mud circulation method using Contractors rig tools, fuel, labourers, bentonite mud and water required for drilling at the site shown by the TWAD Officers including construction of mud pit etc. using only calyx rigs. 70 300mm 71 Charges for developing the borewell with air compressor of 300 CFM capacity (Minimum 8 Hours) including transportation labour and fuel charges for compressor as directed by TWAD Board Officers and conducting yield test by V notch method. 72 Supply and laying following dia PVC casing pipe with excise duty as per IS 12818 / 1992 73 200mm dia CS ( plain pipe) 74 150mm dia CS ( plain pipe) 75 Labour charges for inserting PVC casing pipes assembly (with slots or without slots) in the drilled hole including jointing the pipes with PVC couplers with cement paste etc., complete, supply and packing the annular space with pebbles of size and quality as approved by the Executive Engineer of Departmental officers. 76 200mm dia CS ( plain pipe) 77 150mm dia CS ( plain pipe) 78 Supply and fixing in position whiteEuropean Water Closet of approved make with low level concealed flushing tank 10 litre capacity of best quality and approved make with 100mm P or S trap with double flapped rigid PVC seat cover with CP brass hinges etc. complete complying with standard specification and as directedby the Departmental officers (The EWC should be got approved by the Executive Engineer before use on works.URINAL WITH FIXING ACCESSORIES SET, SIZE - URS-WHT- 13253N 79 Supplying and fixing Wash Hand Basin of size 550 x 400mm with all accessories such as cast Iron Brackets, 32 mm Dia C.P. Waste coupling, Rubber plug and Chain, 32 mm dia B Class G.I. Waste pipe, 15 mm Dia G.M Wheel valve; 15 mm Dia Nylon connection, 15 mm Dia Brass, wast couplingNipples, 15 mm C.P. Pillar tap etc.,including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and as directed by the Department officers.(TheWash basin should be got approved by the Executive Engineer before use on works. 80 Supplying and fixing of CP Two Way Bib Cock with Health Faucet ,wall hook & one metre longflexibletubeincludingcuttingandmakinggoodthe wallswherever requiredetc complete.complyingwithstandardspecificationandas directedbytheDepartmentofficers.Thequalityandmakeofhealth faucet should be got approvedby Concern department Engineer before use on work. 81 Supplying and fixing the best quality approved make of SS heavy duty long body Tap including cutting and making good walls wherever required etc.complete,complying with standerd specification and as directed by the department officers. The quality and make of angular stop cock should be got approved by concern department engineer before use on work. 82 Supplying and fixing in position Mirror of size 600x450mm of approved quality and brand with necessary plastic back PVC frame with bottom stand using brass screws rawl plugs for fixing etc complete complying with standard specification and as directed by the Departmental officers.The colour of frame and quality of mirror should be got approved by the Executive Engineer before use on work 83 Supplying,installing,testing and commissioning of approved make CONCEALED STOP COCK for toilet including neccesary accessories etc,complete,works include making require size curout in wall,and fixing the control box property,redoing the same etc,complete the quality and make of concealed stop cock should be got approved by concern department Engineer before use on work. 84 Supplying and fixing CP angle cock with wall flange including cutting and making good the walls wherever required etc., complete complyingwithstandardspecificationandas directedbythe Engineer Incharge before use on work. 85 Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg ,10 kg /sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications.(The PVC pipes should be got approved by the Executive Engineer before use on works). 86 160mm Dia 6kg 87 110mm Dia 6kg 88 75mm Dia 6kg 89 50mm dia 6kg 90 Supplying andfixingPVC cowl of following size to vertical Soil/Waste pipes above terrace level. The rate including cost of all materials, labour charges and transportation etc. completed as directed by Engineer-in-Charge. 91 110mm dia 92 Supplying & fixing in position PVC Nahini / Floor trap of size 100x75mm including stainless steel gratings of approved brand & quality, fixed over a bed of brick jelly limeconcrete 1:2:5 ( One part of lime, two parts of sand & five parts of 40 mm size brick jelly ) & finished with cement mortar 1:3 ( One cement & three sand ) includingdismantling masonry works wherever found necessary & making good the damaged portions to the original condition & giving connections to the cast iron pipes etc., complete, complying with standard specification. (The PVC Nahini / Floor trap should be got approved by the Executive Engineer before use on works ). 93 Constructing solid block masonry manhole various size of deep in cement mortar 1:3( 1 Cement: 4 coarse sand ) R.C.C. Raft & top slab with cement concrete 1:2:4, plain cement concrete 1:4:8 mixfor base course (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size )above that 150 mm thick RCC M25 raft slab inculding reinforcement 10mm dia 150mm c/c bothways. Plastering inside walls with 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand ) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ), finished with a floatingcoat of neat cement ,supplying and fixing SFRC manhole cover with farame , PVC foot rest as per detailed drawing etc the quoted rate shall also necessary excavation and back filling etc complete.complete as per standard design : (the chamber and cover should be got approved by the Executive Engineer before use on works) 94 Manhole 600 x 600 mm internal size ( Depth up to 1000mm) 95 Supplying, laying and jointing CPVC pipes SDR 11(having working pressure 10 kg. / sq.cm) of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing CPVC specials using CPVC adhesivesand fixing into wall with teak wood plugs, CPVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications.The CPVC pipes shall be got approved by Executive Engineer before use on works.Internal & Vertical 96 a) 20 mm dia 97 b) 25 mm dia 98 c) 32 mm dia 99 Supplying and fixing manhole cover with frame as per approved make ,cover weight and being size mentioned below and specified size in the drawing etc., including painting with two coats of anticorrosive paint over a coat of primer etc., fixing locking arrangements, fixing Man-hole over, grouting the anchors with CC 1:2:4 (one cement,two fine aggregate and four coarse aggregate), as complete in all respects complying with relevant standard specifications and as directed by theClient / Engineer-in-charge.Size:600x600mm 100 Supply & fixing of Bottle trap as per standards. BOTTLE TRAP (WITH INTERNAL PARTITION) 32 - ALD-CHR- 769L300X190 101 LANDSCAPING WORKS 102 Planting of Ixora hybrid foliage shrub variety of height 30-45 cm in polythene bag of size 6x8 inchincluding loading and unloading charges, transportation, stacking of saplings at site, earth work excavation of required size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 103 Planting of Ficus black ornamentalfoliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 104 Planting of Jasmine Plant foliage shrub varietyof height 30-45 cm in polythene bag of size 6x8 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 105 Planting of Travellers palm ornamental foliage Specimen plantvarietyof height 105-120 cm in polythene bag of size 16x16 inch including loading and unloading charges, transportation,stacking of saplings at site, earth work excavation ofrequired size, planting of sapling, refilling of excavated earth etc as directed by the site in-charge. 106 FURNITURE WORKS 107 Linear type Workstation (1000mm(W) X 600mm(D) X 750+300mm(H)) as per below specificationTable Top: - Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with 2mm PVC Edge Banding.Main Screen : -8mm Sandwitch Glass finishes of Sizes 1050x300mm htUnderstructure: - MS Square Leg cross-section of size 50 x 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm. Rectangular Tube made of 1.6mm thick CRCA Powder coated.Raceways : -Vertical Raceways - 120 MM HT MS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Without Middle Cover.Wire Manager: - Wire Manager Hole considered. 108 Storage (Open Shelf) 1200mm 300mm 2100mmIs made 25mm top & all other panel 17 mm thick in prelam particle board finished in Laminate of approved shape, equal shutter 2mm thick edge banding finished. This also includes providing and fixing of hardware like locks, handles, spring loaded hinges etc 109 Supply of Chairs 110 ASPIRE MB (BLACK)* Black Backrest frame, Polished aluminum connected* Mesh back, Seat and headrest fabric* Height adjustable lumbar support with PU surface* Tiltable backrest (can be tiltable when locked inupright position)* 4D adjustable armrest with PU pads* Mould foam with plastic seat upholstery* Mechanism, with seat slide.* Chrome gaslift* Polished aluminum base with plastic cover,* 60mm nylon castors 111 * Versa Medium Back Mesh Chair* AN -70 Mesh* Single Lock Synchro Mechanism* Adjustable Lumbar Support* One Way Adjustable Armrests ( Height)* Nylon Base* Fabric Upholstered Cushion Seat 112 Meeting Room TableTable Top: -Made of 25mm Thick E1 Grade Pre-Laminated Particle Board with PVC Edge Banding,Understructure: - MS Leg 50mm 50mm is Made of Mild Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50*25mm.Raceways : Horizontal RacewaysMS Powder Raceways Considered below the Table top With Intermediated legs considered for Wire Provision.Wire Manager:- Flip Cover Considered. 113 Meeting Room Table (2400mm 800mm 750mm) 114 Cabin Main Table with Side Storage (Main Table 1500mm 750mm 750mm / Side Storage 1200mm 450mm 750mm)Side Storage 1200mm 450mm 750mmTable Top: Main and Side Table Made of 25mm Thick E1 Grade Single Top PLPB with 2mm PVC Edge Banding,Understructure: MS Square 50mm Steel 1.6mm thick CRCA Powder coated.MS Powder Coated horizontal Beams supported below the table top of Size 50mm x 25mm.Flip Cover : Flip Cover 400*143mm Made of AluminiumWire Manager: Wire Box with Socket Plate and Vertebra considered for wiringModesty : Front & Side PLPB Modesty Panel . 115 Librarian TableMain Table 1100mm 440mm 750mm 116 3 Seater Sofa with Table 117 INTERACTS-902 (Leatherette)3 SeaterSize : 1810 (W) x 720 (D) X 740 (H)Made off : the sofa is made of fine quality leatherrite (3s = 8.0 mtr,2s = 6.8 mtr, 1s= 5.3 mtr), the structure is made from silver wood& pine wood, 32 & 40 density foam is used which is covered withroll poly filling for giving comfort and extra softness to sofa. Extra(kangaro company)Legs : are made of stainless steel.Color : Black 118 ELECTRICAL 119 TNEB METER BOX 120 Supply andfixng of TNEB meter board suitable for 3phase100A service connection made up of suitable angle iron frame work of size 2feet x 1-1/2 feet using angle iron of size1-1/2x1-1/2x1/4rigidly fixed on wall covered with hylem sheet of size 2 feet x 1-1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3Nos.100A fuse units (500V), 1No .neutral link,copper earth flat of size1x1/4with inter connection of EB meter to fuse units by 16 Sq.mm PVC insulated copper wire with earth connection complete. 121 M.S. Enclosure (IP65): Supply, Erection , Testing and commissioning of the followingtype M.S. powder coated enclosure for housing the Meteringing service, whch should be made outof16SWG enclosure with provision for cable entry, with Outdoorapplication IP65 as specified Protection, fixed on the wall/Floor withall accessories, pedestal frame with concrete grouting or suitable to fix at concrete plinth etc. 122 MAIN Panels 123 MAIN Panels:Supply, Installation, testing and commissioning of 3Phase, 415Volts, Main LT Panel board of Indoor, Cubicle floor mounting type made out of14 SWG CRCA sheet steel with powder coated finishing, MS base frame, double internal earthing arrangements, 100Amps, rating TPN Copper busbars and Earth bar with interconnection busbar, etc., comprising of the followings:EB Incomer :1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMDG Incomer: 1 No. 100Amps, 25kA, 4Pole, Thermal magnetic MCCB with Ext.RHOMCommon C/O Incomer: 1 No. 100Amps, 4Pole Automatic Changeover Switch with EB ON and DG ON LED Indication lampsMetering : 2 Set of RYB LED Indication lamps2 Nos. of Multifunction Meter with RS 4852 Set of Current Tranformers (200/5A, Cl-1), 1 No. 200/5A CT for APFCR2 Set of Control MCB and Electrical Interlocking between EB & DG Incomers Outgoings: 3 Nos. 63A, 25kA, TP+N, TM MCCB with Ext. RHOM (APFCR &AC)4Nos. 32A, 25kA, TP+N, TM MCCB with Ext. RHOM (Lighting & Spare),6Nos 32A DB MCB inclding all labour Charges And Transports Charges. 124 APFC PANEL: Supply, installation, testing and commissioning of 25 KVAR Automatic power factor correction panel ( APFC ) with 8 steps of capacitor switching cubicle type, free standing, Powder coated, 14 SWG CRCA sheet steel,enclosed separate compartment for each capacitor, front operated, indoor type dust and vermin proof, hinged, lockable doors, electrolytic grade aluminium bus bars, with SMC /DMC insulator supports, Digital volt meter, Ammeter with selector switch, 8 stage Digital Automatic power factor correction,( APFC ), Auto / Manual selector switch, cluster LED typeindicators, in the incomer,complete with electrolytic grade aluminium bus bars, MPP type Power capacitors, with 5 KVAR x 3 no. 3 KVAR x 2 nos. 2 KVAR x 1 nos. 1 KVAR x 2no. Contactors, MCCB’s, start, stop, push buttons, internal wiring, colour coding, ferrules, cable gland plates, Aluminium earth bus for the entire length of the panel with bonding to earth and painting,Panel mounting MS Channels, fasteners, etc., including all associated control wiring and interlocking circuitry, Main panel sensing CT interconnecting wiring etc., all inclusive. 125 Supply, Installation, testing and commissioning of 1 x 58.5KVA, Silent type Diesel Generator Set with AMF Panel complete with suitable size Acoustic enclosure CPCB IV and BIS. Diesel Engine suitable for Generator application, developing 1500RPM with an overloading capacity of 10% for one hour in any 12 continuous hours operation generally confirms to BS:5514, directly coupled to 58.5KVA at 0.8 Power factor, 415V, 3Phase , 4wires, 50cycles per second self excited, self regulated, with brushless excitation, Alternator generally confirms to BS:5000/IS:4722. DG set shall be complete with radiator, residential type silencer, electronic governor, cable termination box, MS mounting frame, fuel piping, diesel day tank, 24VDC Battery, Battery mounting frame, oil level indicator with gauge board, andall other accessories as per standard specifications.Diesel Generator set shall be mounted on cushy foot or similar type of vibration Isolators. The cost of Exhaust pipe shall be included in this item with Sutable concrete Base at M30 Grade. The DG Set shall be suitable for auto-mains failure startand auto / manualoperations.The DG Should be supplied with Auto-Start-Stop Control panel with suitable rating switchgear 126 DISTRIBUTION BOARDS 127 Supply and fixing of 12 way single pole and neutral MCB sheet steel enclosure distribution board with double door (metal) with 1no. 32A DP MCBswitch as incoming and 10 nos. 6A to 32A SP MCB as outgoing in flush with wallwith earth connection only.Higher End 128 Supply and fixing of 4 way Horizontal Triple pole and neutral MCB sheet steel enclosure distribution boardwith double door (metal) with 1 no. 32A 4P MCB switch as incoming and 12 nos. 6A to 32A SP MCB asoutgoing in flush with wall with earth connection only. Higher End 129 Supply and fixing of 7 segment 4 way TPN MCB sheet steel distribution board (Higher end) with metal / acrylic door cover flush type /surface type fitted with busbars and neutral links with single / three phase MCB outgoings and seperate 4 way provision for accomodating one no. 4 pole incoming MCB / Isolator and another seperate 4 way provision for accomodating one no. 4 pole ELCB / RCD (totally 8 ways in one segment) (3x 4 ways in each segment) and seperate provision for MCB / Isolators ( totally 12 nos.) for sub incomers in 3 segments with lable holder and provison for taking up cable for size not less than 35 sq.mm.with the following in flush with wall with earth connection only. i. 63A 4P MCB - 1 no.ii. 63A 4P 30MA RCCB/ELCB - 1 no.iii. 63A DP MCB Isolator -3 nos.iv. 6A to 32A SP MCB - 12 nos., 130 Supply and Laying of 3 1/2x 70 sq.mm. PVC armoured LTUG cablein suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. 131 Supply and fixing of brass cable gland for 3-1/2 x 70 sq.mm. PVC armoured LTUG cable with earth connection. 132 Supply and providing cable end termination of 3-1/2 x 70 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete. 133 Run of Mains 134 Supply and Run of 4 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 135 Supply and Run of 2 of 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection by 4 sq.mm. PVC insulated SC unsheathed FRLS copper wire and making good of the concealed portion. 136 Supply and Run of 2 of 10 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 10 sq.mm copper wire and making good of the concealed position. 137 Supply and Run of 2 of 2.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 2.5 sq.mm copper wire and making good of the concealed portion. 138 Point Wiring 139 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) Higher End Primary Point. 140 Wiring with 2 x1.5 sq.mm. PVC insulated single core unsheathed FRLS copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with continuous earth wire connection of 1.5 sq.mm copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator)Higher EndSecondary Point. 141 Switch & Sockets 142 Supply and fixing of 1 no.6A two module 5 pin socket , 1 no.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 143 Supply and fixing of 2nos.6A two module 5 pin socket , 2 nos.6A one module switch with module cover plate (plastic) onsuitable module concealedBox (GI ) in flush with wall with connections. Higher End 144 Supply and fixing of 1 no.6/16A two modulesocket , 1 no.16A one module switch with module cover plate (plastic) on Suitable module concealedBox (GI ) in flush with wall with connections. Higher End 145 Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earth connection (For AC Plug) 146 Air Condition 147 Supply & Instalation of Air-Conditioner with Copper Coil 2.0 TR Split Type AC Unit - 5 Star Rated, 5 KVA capacity Automatic Voltage Stabilizer with time delay relay, 5/8” and 3/8” copper pipe (Extra beyond 3 metres supplied with AC unit), Inculding MS stand for fixing outdoor unit. 148 Supply and fixing of Copper Refrigerant Piping of 3/8 dia and 5/8with Pipeline nitrle rubber insulation with 50mm PVC water drain pipe line with Non Adhesive Cotton Roll insulation and 3 core Power cable from indoor to Outdoor unit. 149 Supply and fixing of 450mm (18) Wall mounting 5 star rated complete (Higher end) with necessary accessories and hardwares as required. 150 Supply and fixing of 300mm (12) sweep(Heavy Duty) AC exhaust fan complete with necessary wall opening and making good of the wall . 151 Supply and fixing of louvers shutters arrangements for 300mm (12) sweep AC exhaust fan 152 Supply and fixing of 24W LED 2x2 square type Recessedfitting with LED (Higher end) on false Ceiling with suitable hanging support from ceilingwith PVC unsheathed copper leads from terminals to the fitting 153 Supply and fixing of 18W LEDRound type Recessedfitting with LED (Higher end) on false Ceiling from ceilingwith PVC unsheathed copper leads from terminals to the fitting. 154 Supply, installation, testing and commissioning of36 W, 900mm diaCircular LED pendantlight fitting, made out of CRCA powder coated body, aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, suitable for recessed mounting including electronic drivers, day light colour LED lamps, inter connecting wiring including accessories all inclusive. KL 3232 155 Supply and fixing of28Watts GATE FIXTURE FITTINGwith cool day light suitable for wall / roof sheet mounting, made outCRCA powder coated body,IP65 aluminium reflectors,poly methyl meth acrylate (PMMA) diffuser, glare free light, including electronic drivers, day light colour LED lamps, inter connecting wiring with suitable fixing clams, hooks as required including accessories all inclusive.(Klite/Millenium/Bajaj Equivalent) 156 Supply and fixing of 8W Light fitting (IP67) Inground fixture with PVC unsheathed copper leads from terminals to the fitting and to complete necessary accessories and etc to complete the work. (Klite/Millenium/Bajaj Equivalent) 157 Supply and fixing of MIRROR Light 20W LED Batten 158 Supply and erection of Canon Digital Photocopier (Xerox) Machine IR-3300 / 3235Type of Product : Laser Multi functionalCore Functions: Print, Copy, Scan & SendFirst Copy Time:3.9 SecMultiple Copies :1 to 999 SheetsPrint Speed :45ppmThe laser beams engrave the image or text that you have sent to print on the surface of the drum. When using a copier this process is done using light, the light scans the page required for printing and converts it into an image 159 Supply and erection ofAll-in-one Desktop of HP 27-cb1456in Core i5 (8GB DDR4 /Windows 11 Home/27 Inch Screen/27-cb1456in) with 600VA UPS, Keyboard, Mouse,27 inches, 11th Gen Intel Core i5-1235U6 x 1.8 GHz (Turbo Speed upto 4.2 GHz) Cores Hexa Core, 12 Threads, 18 MB Cache, UHD Graphics 730 Graphics, 8 GB DDR4 RAM Smallest and 512 GB SSD.Ethernet (LAN), HDMI, Multi Card Reader,WiFi, Bluetooth v5.03 x USB 3.0, 1 x USB Type-C and Inbuilt Microphone 160 PRINTER: Supply, installation, testing and commissioning of HP Smart Tank 790 WiFi All-in-One Printer Duplexer with ADF and Magic Touch Panel Inkjet Colour printer, print speed 11-20 sheets with multiple features like print, scan, copy, fax, multi-port connectivity (Hi-speed USB 2.0, Wifi, Bluetooth LE , 1 USB Host, LAN) , 2.4/5G dual band Wi-Fi, Wi-Fi Direct, mobile printing capability, etc 161 Supply, installation, testing and commissioning of Long Range Wifi Device of following Specification: Networking Interface: (1) GbE RJ45 PortPower Method: PoE+, Pasive poE(48V) Max TX power: 2.4 GHzAntenna gain: 2.4 GHzMounting: Wall or Ceiling MountingWifi Satndards : 802.11a/b/gWireless security: WPA-PSK, WPA- Enterprises(WPA/WPA2/WPA3)VLAN: 802.1Q Concurrent Clients: 300+ 162 CCTV 163 Supply, Installation, Testing and commissioning of 16 channel 2 SATA NVR, with 6TB Hard Disk Drive 2 nos, New logical and visualized GUI design Dual-OS design to ensure high reliability of system running, ANR technology to enhance the storage reliability when the network is disconnected,Configurable normal or hot spare working mode to constitute an N+1 hot spare system Video Input and Transmission, Connectable to the third-party network cameras Compression and Recording, H.265+ compression effectively reduces the storage space by upto 75%, Full channel recording at up to 12MP resolution HD Video Output  HDMI1 / VGA1 outputs provided  HDMI1 Video output at up to 4K ( 3840 × 2160 ) resolution Storage and Playback, Upto 16 SATA interfaces and 1 eSATA interface for HDD connection, Support upto 10TB capacity for each HDD, Smart search for efficient playback. and smart playback to improve the playback efficiency, Supports VCA search for fire/ship/temperature/temperature difference detection triggered video files, POS information overlay on live view and playback, POS triggered recording and alarm Network & Ethernet Access  Hik-Connect for easy network management, 2 Gigabit Ethernet network interfaces. (Make : Hikvision / Dahua / Sony. 164 Supply of 4MP, Internet Protocol fixed BULLET CAMERA/DOME CAMERA (INDOOR & OUTDOOR)with following specification:●1/2.5 Progressive Scan CMOS, ● 3840 × 2160 @15 fps,2.8/4 mm fixed lens,01 lux @ (F1.2, AGC ON), 0.028 lux @(F2.0, AGC ON), 0 lux with IR, H.265+, H.265, H.264+, H.264, 2 Behaviour analyses ( Line crossing detection, intrusion detection)● Face Detection ● 120dB WDR, ● BLC/3D DNR/ROI, IP67 complied●On-board Storage -Built-in micro SD/SDHC/SDXC card slot, up to 128 GB,● Shutter Speed 1/3 s to 1/100,000 s, ● 3-Axis Adjustment Pan: 0° to 360°, tilt: 0° to 100°, ● rotate: 0° to 360°, 2.8 mm, ● horizontal FOV: 102°, vertical FOV: 53°, diagonal FOV: 124°, ●Lens Mount M12 ● IR Range I5: up to 50 m, ● Image Settings Rotate mode, saturation, brightness, contrast, sharpness adjustable by client software or web browser, ● Power Consumption and Current-12 VDC, 0.7 A, max. 7.5W PoE: (802.3af, 36V to 57V), 0.3 A to 0.2 A, max. 9W● Camera out fitted with metal housing so as to prevent the lens from damages during physical abuse. with Camera Stand and camera fixed connecting box. (Make: Dahua/Panasonic) 165 Supply, Installation, Testing and Commissioning of 32 smart LED TV with following specifications a) Full HD 1920 x1080 (4K monitor) b) IPS panel c) Slim back light LED module d) 900 PMI e) Triple XD engine f) Dynamic scanning g) ANRh) True colour generatori) 8modes of picture j) picture wizardIII k) Real cinema 24P l) HDMI -3nos m) USB -3nos n) Built in LAN (Make: Sony/ LG /Samsung). 166 Supply and Clamping of CAT 6 unarmoured cable in suitable PVCPipe 1 thick on wall / ceiling with connected PVC accessories with clamps, saddles etc., complete. (Between ethernet switch to camera and radio modem)i. Application : Primary (Campus), Secondary (Riser), Tertiary(Horizontal)IEEE 802.3 : 10Base-T; 100Base-T; 1000Base-TIEEE 802.5 16 MB; ISDN; TPDDI; ATMii. Standards: ISO/IEC 11801 2nd ed.; IEC 61156-5 2nd EN 50173-1; EN 50288-6-1,EIA/TIA 568C.2, RoHS Compliant. ii)Fire Rating: PVC : IEC 60332-1.iii. Conductor - Bare Copper Wireiv. Insulation - Polyethylene v. Twisting - 2 Cores to the pair vi. Cable lay up - 4 Core to the pair It has diameter of (23 AWG) 0.550 ± 0.015.Insulation : Polyethylene.GI wire of size is 0.90 ± 0.030mm. 167 Supply and Fixing of Rack with Accessories -Higher end9U Rack with fan extra for the above rack. (Amp/NVR/POE) 168 Supply and Fixing of Rack with Accessories -Higher end4U Rack with fan extra for the above rack. (speaker/data/cctv) 169 Supply and fixing of POE 24 port switch10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 170 Supply and fixing of POE 8 port switch with two uplink port, 10/ 100 / 1000 Base -T / 2 x 1000Base-FX / 20Gbps bandwidth / IEEE803.af/at compliant PoE+ / RJ45 supports auto MDI/MDI-X function / Auto negotiation speed, half/full-duplex / Store and forward / Max packet size: 10kbytes / Wide range power design (12~56VDC) / Operating temperature (-40 ̊C ~ +75 ̊C) / Reverse polarity protection / Resettable fuse to protect against overcurrent / IP-40 protection / EFT protection for power line. (Make: DLINK,NETGEAR/ TPLINK) 171 Supply and fixing of outdoor4X6PVC box with 102mm x 77mm x 102mm with all fixing accessories. 172 Supply, Fixing and Termination of CAT 6 Cable RJ 45Jack Single Point ( Point to Point ) Crimping, Testing and arrangement charges. 173 Supply and Installation for 1KVA UPS with Battery, Single Phase UPS (Single Phase In & Single Phase Out) Capacity - System with Battery - 2 Hours back up and battery stand . 174 Supply, Erection of 6mLengthpole with base plate of size 300x300x12mm as per IS-875 with following specification. Pole Outter dia -76.10mm x 3.65mm Thick x 6 meter with foundation Charges. 175 VOICE & DATA 176 Supply, Fixing and Termination ofRJ 11 Single Point ( Point to Point) Crimping, Testing and arrangement charges. 177 Supply & Installation of CAT 6 PVC Module Box I/o socket & face plate single socket Erection and arrangement chargers (Higher end) 178 Supply and fixingofLAN Network Switches Un-Managed 10/100/1000 - 24 Port and 24 Port Patch Panel- Unloaded erection and arrangement chargers. 179 Supply, runing, testing and commissioning of2 Pair Unarmoured 0.5mm Telephone cable in suitable Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 180 PA SYSTEM 181 Supply, Installation,Testing & commisioning of 15W Wall Speaker 2 way high efficiency, high fidelity, long throw IP65 weather proof P.A Music Horn speaker. It combines the high efficiency of horn with wide frequency response.Music horn is weather protected and UV protected ABS plastic housing combines with the feature of easy poertap selection on a terminal strip with a two core cable.It has impedence of 250/500/1k/2k ohm with frequency response of 120-16000 hertz. (Make:AhujaAMH402T/Bosch or its equivalent) 182 Supply, Installation,Testing & commisioning of 120 watts P.A Mixer Amplifier with the output power of 120 watts maximum 160watt rms at 10% Thyristor harmonic distortion(THD), 850watt RMS at 5% THD, 800 wattsRMS at 2% THD and the power supply AC voltage ranging from 220-240 volt, 50/60 hertz. with the DC input of 48 volt and 1000watts has tone controls of Bass=+- 10 db at 100 hz weighing 42kg with the speaker output of2Q,4Q.70volt&100volt has power consumption of 1600VA AC &12A DC and 100db output regulation at 1khz no load to full load ratio. The signal to noise ratio is 60db with the imnput channels of 0.8mv/4.7kq,3*Aux 100mv/50kq.The frequency response of 50-15000hz+-3db.(Make:Ahuja SSA 10000/Bosch) 183 Supply, runing, testing and commissioning of2Core x 1.5sq sqmm PVC insulated un Armoured Speaker Cable in suitable 20mm dia Pvc Rigid pipe concealed on wall and ceiling with continuous earth wire connection with painting of suitable colour. 184 Earthing 185 Earthing as per the ISI specification with an earth electrode of 2.10 metre Class B GI pipe of dia not less than 40mm withcopperearthplateofsize125mmx50mmx6mmwithnecessaryfunnellingarrangementswithnecessary masonry work and with 38mm RCC cover slab for the brick masonry 186 Supply and erection of 17.2mm, 3mtr long, Copper Bonded earth rod with backfill compound, including civil worksof base PCC for chamber andheavy duty Chambercover,, heavy duty chamber cover, etc., as per IS 3043 standards 187 Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection 188 Supply and Run of1 of No.8 SWG copper wire for earth connection 189 Supply and Run of1 of No.8 SWG copper wire in suitable PVC rigid pipeon wall / floor / ground for earth connection 190 Supply of 2mx1mRubberMatsuitablefor11KVinstallation confirming to IS(5 Nos) 191 Supply of First Aid Box complete with all First Aid Medicines 192 Supply and fixing of Shock Treatment chart with Glass frame 193 Supply and fixing of4 Nos. Fire Buckets made out of 40 x 40 x 6mm MS Angle 194 Supply and fixing of Fire Extinguishers Co2, 4.5Kg confirming to TAC norms 195 Supply and fixing of Metallic Danger Board as required by the Electrical Authorities 196 METAL SIGNAGE BOARDS: Supply and fixing of metal signages for the following:1. Mudhalvar Padaipagam text in Tamil of size 20 x 15with backlit LED placed over the base, fabricated using stainless steel sheet of minimum 16G thickness brush finish of required size and colour as required. 197 LOGO SIGNAGE BOARD 198 LOGO SIGNAGE BOARDS: Supply and fixing of acrylic signages for the following:1. Mudhalvar Padaipagam logo of size 2 x 22. CMDA logo of size 2 x 33. Directorate of Public Libraries logo of size 3 diawith backlit LED placed over the sun board base, SIDE EDGES(4): 5mm transparent white acrylic sheet with laser cut & 4inches manual raising all around with details. ACRYLIC SHEETS & ITS TECHNICAL PARAMETERS:Front: a. 5mm Imported (Mitsubishi/equivalent) acrylic cutting on laser cutting machine.b. Flexi bond make 25mm Sun board for the back of the logo.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 2
24.
Educational and Research Institute #10160062 Price Bid
Name Of Work: Notice Inviting E-Tender For Procurement Of Equipment, Instrument, Machineries, Tools Etc. Related To Laboratories Of Civil Engineering, Electrical Engineering, Mechanical Engineering And Physics Laboratory Of Raipur Govt. Poytechnic, West Bengal. - 1 Compacting Factor Test Apparatus 2 Core Cutter Testing Apparatus 3 Digital Schmidst Rebound Hammer 4 Ultrasonic Pulse Velocity Test Apparatus 5 Rebar Locator 6 Piezometer Tube 7 U-Tube Manometer 8 U-Tube Differential Manometer 9 Current Meter 10 C.O.D Analyzer Kit 11 Plane Table With Tripod Stand With Accessories 12 Plotter Machine 13 All Geared Head Lathe Machine With All Standard Accessories 14 Cone Pulley- Back Gear Type Centre Lathe With All Standard Accessories 15 Radial Drill Machine 16 Arc Welding Equipment : Arc Welding Cable 17 Arc Welding Equipment : Arc Welding Holder 18 Arc Welding Equipment : Arc Welding Electrode 19 Arc Welding Equipment : Safety Welding Helmet 20 Arc Welding Equipment : Safety Glasses 21 Arc Welding Equipment : Chipping Hammer 22 Double Wheeled Bench Grinder ( For M / C Shop , Fitting & Welding Shop ) 23 Abrasive Cut Off Machine 24 Inductive Load Box 25 Digital Multimeter 26 Panel Mounted Ammeter 27 Table Top Ammeter 28 Extension Board ( Spike Guard ) 29 Single Phase Preventer 30 Transformer Oil 31 Contactor Block 32 Panel Mounted Digital Timer 33 Ferule Type Fuse 34 Arduino Project Kit 35 Contact Type Tachometer 36 Xlpe Cable ( Red ) 37 Xlpe Cable ( Yellow ) 38 Xlpe Cable ( Blue ) 39 Xlpe Cable ( Black ) 40 Xlpe Cable ( Green ) 41 To Measure Unknown Capacitance By Schering Bridge 42 Dc Power Supply 43 Cable Crimping Tool 44 Different Types Of Cable Lugs 45 3 Phase Variac 46 3 Phase Synchroscope 47 Different Pilot Devices: Push Button Switch ( No, Nc ) , Limit Switch, Selector Swich, Pressure Switch, Float Switch, Toggle Switch, Ryb Indicators, Emergency Stop Switch 48 Capacitor Bank 49 Different Types Of Power Insulator Used In Transmission And Distribution Line 50 Model Of Supply System Of 6.6 Kv / 400 V Substation To Housing Complex 51 Model Of Different Types Of Excitation System For Alternator 52 Pv System Used In Street Lighting 53 Working Model Of Power Generation By Wind Power 54 Different Models Of Circuit Breakers 55 Lightning Arrestor Model 56 Different Type Of Fuses Fitted In Study Board 57 Different Types Oflamps With Necessary Chock, Starter, Transformer 58 Study Of Electric Arc Welding Using Welding Transformer 59 Study Of Induction Heating Using Induction Heater 60 Vernier Caliper 61 Screw Gauge 62 Sperometer 63 Concave & Convex Mirror, Focal Length 20 Cm 64 Concave & Convex Mirror, Focal Length 50 Cm 65 Concave Surface 66 Glass Slab, Dim.- 7.5X5x1.8 ( Cm3 ) 67 Glass Slab, Dim.- 10X6x1.8 ( Cm3 ) 68 Wood, Metal Inclined Plane Aparatus For Determining Coefficient Of Static Friction Between Wood And Glass 69 Hooks Law Apparatus 70 Mercury 71 Magnet 72 Small Hollow Metal Cylinder 73 Small Crome Steel Bearing Balls 74 Linear Expansion Vertical Apparatus 75 Fly Wheel Apparatus
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 14
West Bengal View Result →
25.
Educational and Research Institute #10156235 Price Bid
Equipment , Purchase Of Equipment , Specifications For Inverted Fluorescent Cell Imager: 1) Imaging Channels: Bright Field Channel And Minimum 3 Fluorescence Channels (Must Include Blue, Green, And Red) 2) Illumination Light Sources – Minimum 3 Led Cubes (Must Include For Blue Channel, For Green Channel, For Red Channel) 3) Bright Field Channel: Multiple Green Leds 4) Excitation And Emission Spectra A) Blue Channel Excitation: 355/40 Nm; Emission: 433/36 Nm B) Green Channel Excitation: 480/17 Nm; Emission: 517/23 Nm C) Red Channel Excitation: 556/20 Nm; Emission: 615/61 Nm 5) All Dyes And Fluorescent Proteins With Compatible Excitation And Emission Spectra Should Be Used. 6) User Interface: Minimum 10.1 In. Color (26 Cm) Touch-Screen Lcd Monitor, With Anti-Glare And Anti-Fingerprint Treatment 7) Image Resolution: Minimum 1,280 X 768 Pixel Image Resolution, 80–180° Angle Tilt Range 8) Focusing Mechanism Of Coarse And Fine, Manual/Automated Adjustment 9) Monochrome Camera With 12 Bit Cmos, Minimum 3.2 Megapixels 10) Data Format; Jpeg, Tiff, Or Raw Image Files 11) Image Merging Capability – Images From Up To 4 Channels Can Be Overlaid 12) Data Storage: Minimum 4Gb Internal Memory 13) Data Export: Minimum 2 Usb Ports 14) Display Output: 1 Hdmi Port 15) Objective Of Minimum 20X With Numerical Aperture 0.40 16) Display Magnification Should Be Standard:Minimum 100X And Zoom With 700X 17) Maximum Imaging Area: 0.70 Mm2 Field Of View 18) Motorized Stage: Minimum 6 Mm Travel In X, Y Direction, Touch-Screen Or Software Control Of Travel Speed And Direction 19) Compatibility – Flasks: T25, T75, Or T225 & Multi-Well Plates: 6-, 12-, 24-, 48-, 96-, Or 384-Well Microplates, Petri Dishes: 35Mm, 60 Mm, Or 100 Mm 20) Slides: Chamber Slides Or Standard Glass Microscopy Slides 21) Integrated Onboard Software 22) Stand-Alone Android Operating System. 23) Warranty: 1 Year For The Instrument.
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
26.
Power #10152320 Price Bid
construction of Katar Nallah Ph-Ii Mhs (1 X 100 Kw) At Limeking In Upper Subansiri District (Sh - Supplying, Erection, Testing And Commissioning Of Electro-Mechanical Equipment Complete On Lump Sum Fixed Tender)-Design and manufacturing Horizontal Francis Turbine to deliver 100 kW,1000 rpm at generator terminals with shaft, runner, casing, bearings, oil pressure units etc. and all other auxiliaries with 10% continuous over rating conforming to relevant international specifications. 3 Design, manufacturing and Supply of Synchronous Generators 100 kW 0.415 kV, 3 phase, 0.8 Pf, 50 HZ + 3%, 1000 rpm Brushless Excitation,class F insulation for rotor and classF insulation for stator, necessary terminal equipment like neutral grounding system LA/SC and other auxillary systems as required complete with 10% continous over rating suitable for above turbine. 4 Design, manufacturing and Supply of Generator/Turbine control panels including ACBs, protection, metering systems, all indicating instruments & switches, arrangement of power house lighting & auxillaries etc with one synchronising panel including provision for synchronising the power house with GRID. 5 Design, manufacturing and Supply of Electronic load controller of reputed make with delta connected ballast loads suitable for governing and regulation of above turbine-alternator system complete in all respect and GRID synchronising. 6 Main inlet valves suitable for fixing on penstocks for emergency closure (butterfly valve) complete with mounting flanges. 7 STATION AUXILIARIES 8 1.1 kV Power and Control cable with accessories as per site requirement. 9 24 Volts 200 AH D.C. Battery, Charger and Distribution Board. 10 Design, manufacturing and Supply of Station Service Board including bus bar, with MCCBs/ MCBs etc. of adequate capacities including 10 KVA Station Aux. T/F complete with all accessories as per site requirement. 11 Earthing of Power House & Switchyard equipment as per IS:3043 and IE Rules 1956 as amended upto date. 12 Any other items required for project completion and successful commissioning. 13 Erection, Testing & Commission
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
Arunachal Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 6.30 Crore
Government Departments No of Bidders 1
28.
Defence #10102034 Price Bid
Purchase Of Psu Items ( Tatra Spares ) Through Single Cover System - 1 Lv7 / Hrv Av-15 152-338 Hose 722 20 1010 1900 2 Lv7 / Hrv Av-15 443-332-028-0 Special Mirror 3 Lv7 / Hrv Av-15 273-111-540-191 Wipering 60 4 Lv7 / Hrv Av-15 324-712-220-000 Bearing 30222 5 Lv7 / Hrv Av-15 443-851-003-021 Switch V-45 6 Lv7 / Hrv Av-15 466-437-252-010 Temperature Indicator 7 Lv7 / Hrv Av-15 532-038-560-231 Cross N 8 Lv7 / Hrv Av-15 571-491-265-815 Motohours Counter 500239 9 Lv7 / Hrv Av-15 574-173-260-890 Charger Case 10 Lv7 / Hrv Av-15 336-632-581-104-00 Hose 722251010400 11 Lv7 / Hrv Av-15 578-003-013-852-62 Thrust Ring 12 Lv7 / Hrv Av-15 578-003-016-452-62 Socket 13 Lv7 / Hrv Av-15 578-003-017-252-62 Socket 14 Lv7 / Hrv Av-15 578-003-020-852-80 Pully 15 Lv7 / Hrv Av-15 578-003-022-052-30 Bush 16 Lv7 / Hrv Av-15 578-003-022-152-30 Pawl 17 Lv7 / Hrv Av-15 578-003-034-152-62 Bush 18 Lv7 / Hrv Av-15 578-003-037-452-80 Encl Piece 19 Lv7 / Hrv Av-15 578-003-048-052-62 Flow Screw 20 Lv7 / Hrv Av-15 578-003-048-152-62 Reducing Sleeve 21 Lv7 / Hrv Av-15 578-003-048-552-62 Reducing Sleeve 22 Lv7 / Hrv Av-15 578-003-048-652-62 Nut 23 Lv7 / Hrv Av-15 578-003-053-052-62 Socket 24 Lv7 / Hrv Av-15 578-003-070-352-62 Pressure Hose 25 Lv7 / Hrv Av-15 578-003-070-452-62 Hose 28X5x300 26 Lv7 / Hrv Av-15 578-003-100-152-34 Planet Wheel 27 Lv7 / Hrv Av-15 578-003-100-152-43 Gear Wheel Zz 28 Lv7 / Hrv Av-15 578-003-100-252-63 Driven Gear 29 Lv7 / Hrv Av-15 578-003-100-352-41 Central Upper Ring 30 Lv7 / Hrv Av-15 578-003-100-452-41 Central Lower Ring 31 Lv7 / Hrv Av-15 578-003-100-452-43 Shaft 32 Lv7 / Hrv Av-15 578-003-100-552-63 Gear Wheel 33 Lv7 / Hrv Av-15 578-003-100-752-43 Shiftable Sleeve 34 Lv7 / Hrv Av-15 578-003-102-052-28 Pivoting Strip 35 Lv7 / Hrv Av-15 578-003-102-652-63 Shaft 36 Lv7 / Hrv Av-15 578-003-103-252-16 Packing Ring 37 Lv7 / Hrv Av-15 578-003-103-452-43 Planet Wheel 38 Lv7 / Hrv Av-15 578-003-103-752-43 Carrier 39 Lv7 / Hrv Av-15 578-003-104-052-34 Bevel Gear 40 Lv7 / Hrv Av-15 578-003-104-252-34 Driving Wheel 1.1 41 Lv7 / Hrv Av-15 578-003-114-252-43 Shaft Idler 42 Lv7 / Hrv Av-15 578-003-115-152-60 Bevel Gear 43 Lv7 / Hrv Av-15 578-003-116-952-43 Crownel Wheel 44 Lv7 / Hrv Av-15 578-0003-120-652-43 Wedge 45 Lv7 / Hrv Av-15 578-003-910-352-32 Cable 551-552 46 Lv7 / Hrv Av-15 578-003-910-452-85 Rope 47 Lv7 / Hrv Av-15 578-003-911-352-62 Double Return Valve 48 Lv7 / Hrv Av-15 578-003-911-652-16 Splined Shaft & Fork 49 Lv7 / Hrv Av-15 578-003-912-252-30 Door Complete Welment 50 Lv7 / Hrv Av-15 578-003-912-252-64 Cover Complete 51 Lv7 / Hrv Av-15 578-003-912-652-43 Piston Complete 52 Lv7 / Hrv Av-15 578-003-913-952-28 Hauling Rod Rigid 53 Lv7 / Hrv Av-15 578-003-914-952-28 Cabin Linkage 54 Lv7 / Hrv Av-15 578-003-917-452-80 Bar Complete 55 Lv7 / Hrv Av-15 578-003-922-752-28 Pin With Handle 56 Lv7 / Hrv Av-15 578-003-923-252-62 Pin Complete 57 Lv7 / Hrv Av-15 578-003-929-152-62 Filter 58 Lv7 / Hrv Av-15 578-003-944-152-28 Rope Link 2X3400 Kg 59 Lv7 / Hrv Av-15 578-903-915-252-43 Pipe Assy 60 Lv7 / Hrv Av-15 578-903-917-252-80 Indicator 61 Lv7 / Hrv Av-15 578-903-917-652-80 Pin Complete 62 Lv7 / Hrv Av-15 578-903-926-452-62 Fine Filter 63 Lv7 / Hrv Av-15 578-003-910-252-15 Disc Support 64 Lv7 / Hrv Av-15 578-003-910-352-69 Pin 40 65 Lv7 / T-816 993-050-274-0 Filter Lubricating Oil 66 Lv7 / T-816 627-936-003-0 Insert C 33 67 Lv7 / T-816 443-999-043-0 Brake Cylinder D 115 68 Lv7 / T-816 993-100-854-0 Excitation Winding 69 Lv7 / T-816 993-050-386-0 Compressor Hx55 70 Lv7 / T-816 993-050-009-0 Alternator 71 Lv7 / T-816 993-050-347-0 Injector 72 Lv7 / T-816 442-900-134-0 Fuel Filter 900 Fgp-324-10 73 Lv7 / T-816 298-903-070-4 Mudguard Rh 74 Lv7 / T-816 347-222-061-0 Bulb H4-24V 75 / 70W P43 T Hd-94196 75 Lv7 / T-816 993-101-092-0 Flame Glow Plug 76 Lv7 / T-816 993-100-232-0 Fuel Fileter 0117 4422 77 Lv7 / T-816 443-612-012-0 Hand Brake Valve 961 723 123 0 78 Lv7 / T-816 324-545-046-0 Needle Bearing Inahk 1010 79 Lv7 / T-816 993-100-855-0 Starter Penion 80 Lv7 / T-816 993-101-211-0 Fuel Injector 81 Lv7 / T-816 993-100-856-0 Magnet / Solenoid Switch 82 Lv7 / T-816 443-724-020-0 ( T-816 ) Hand Pump Dhp 6002-21-81 83 Lv7 / T-816 443-853-140-0 Convoy Switch V.Vs10 12002021A8 Vomc 84 Lv7 / T-816 993-050-028-0 Sensor, Temperature 85 Lv7 / T-815 ( 4X4 ) 442-053-610-054 Sealing Ring Js 6 86 Lv7 / T-815 ( 4X4 ) 442-053-111-294 Hose -28 / 38-140 87 Lv7 / T-815 ( 4X4 ) 442-053-111-044 Hose 40 Mm 88 Lv7 / T-815 ( 4X4 ) 442-052-382-314 Screw 89 Lv7 / T-815 ( 4X4 ) 442-076-612-914 Injector Line 1St Cylinder 90 Lv7 / T-815 ( 4X4 ) 442-071-430-534 Gear-Tube Shift 91 Lv7 / T-815 ( 4X4 ) 442-079-011-844 Clamping Strip 92 Lv7 / T-815 ( 4X4 ) 442-073-560-374 Handle Assy For Spare Wheel 93 Lv7 / T-815 ( 4X4 ) 324-718-130-100 Roller Bearing 32313 A 94 Lv7 / T-815 ( 4X4 ) 442-051-361-384 Thermometer Plug 95 Lv7 / T-815 ( 4X4 ) 442-052-390-884 Stud Bolt 96 Lv7 / T-815 ( 4X4 ) 442-051-361-654 Plug M 42X2 97 Lv7 / T-815 ( 4X4 ) 107-110-114-000 Hex. Nut M10 Is:1364 98 Lv7 / T-815 ( 4X4 ) 442-052-380-154 Centering Screw 99 Lv7 / T-815 ( 4X4 ) 324-712-212-000 Bearing 30221A 100 Lv7 / T-815 ( 4X4 ) 205-257-148-4 Nut 101 Lv7 / T-815 ( 4X4 ) 201-881-239-4 Propeller Shaft 102 Lv7 / T-815 ( 4X4 ) 131-400-168-000 Cable Clip - 140X3.6 103 Lv7 / T-815 ( 4X4 ) 201-881-184-4 Propeller Shaft 104 Lv7 / T-815 ( 4X4 ) 201-881-088-4 Rear Propeller Shaft 105 Lv7 / T-815 ( 4X4 ) 273-121-015-660 Rubber Bushing-11X1 Csn 63 3881.1 106 Lv7 / T-815 ( 4X4 ) 273-110-361-000 Sealing Ring 62.3X5.7 Beier Fkm 75 107 Lv7 / T-815 ( 4X4 ) 442-079-013-784 Conductor 108 Lv7 / T-815 ( 4X4 ) 990-700-469-000 Air Fan Insert - Wabco 4324100202 109 Lv7 / T-815 ( 4X4 ) 311-901-072-000 Sealing Ring 110 Lv7 / T-815 ( 4X4 ) 317-814-037-000 Cut Out Fuse 3 Wk 503 01 10A 111 Lv7 / T-815 ( 4X4 ) 317-814-035-000 Cut Out Fuse 3 Wk 503 01 5A 112 Lv7 / T-815 ( 4X4 ) 443-654-130-000 Hose-Ab 309, 8X800 Dkl-Dkl Pnd 21 / 310 113 Lv7 / T-815 ( 4X4 ) 442-960-730-054 Knob 3 114 Lv7 / T-815 ( 4X4 ) 442-050-400-304 Slide Valve 115 Lv7 / T-815 ( 4X4 ) 548-212-002-000 Insert-6X15 203 63 00024 116 Lv7 / T-815 ( 4X4 ) 442-985-511-594 Center Carpet Lh 117 Lv7 / T-815 ( 4X4 ) 443-859-008-000 Fuse For Lorries 1 / 8A 118 Lv7 / T-815 ( 4X4 ) 443-999-252-000 Brake Shoe 119 Lv7 / T-815 ( 4X4 ) 443-937-150-250 Brush Holder 120 Lv7 / T-815 ( 4X4 ) 442-072-783-004 Transfer Gear Box 121 Lv7 / T-815 ( 4X4 ) 443-612-127-0 Brake Cylinder 425 428 950 0 122 Lv7 / T-815 ( 4X4 ) 548-212-003-000 Insert-8X13 203 66 00024 123 Lv7 / T-815 ( 4X4 ) 442-050-953-644 Washer 0.1 Mm 124 Lv7 / T-815 ( 4X4 ) 201-881-103-4 Front Propeller Shaft 125 Lv7 / T-815 ( 4X4 ) 207-148-037-4 Synchro Mesh 4-5 126 Lv7 / T-815 130-071-150-234 Shifter Fork-Ii-Iii 127 Lv7 / T-815 130-076-633-954 Union Piece 128 Lv7 / T-815 130-076-690-644 Adjusting Connector 129 Lv7 / T-815 130-071-480-364 Synchromesh Mechanisam 130 Lv7 / T-815 130-075-720-714 Yoke 131 Lv7 / T-815 130-071-110-514 Gear Shift Lever 132 Lv7 / T-815 130-075-150-174 Push Button 133 Lv7 / T-815 130-051-110-874 Valve Spring Cup 134 Lv7 / T-815 130-072-610-054 Glide Prism, Guide Block 135 Lv7 / T-815 130-076-631-134 Fuel Return Tube 136 Lv7 / T-815 130-054-032-784 Gasket 0.25Mm 137 Lv7 / T-815 130-073-011-134 King Pin, Lh Iii 138 Lv7 / T-815 130-054-471-654 Clamp 139 Lv7 / T-815 443-960-524-114 Safety Thermo Switch 140 Lv7 / T-815 5310 240690 Lock Washer A -21 Is: 8068-76 141 Lv7 / T-815 2805 002791 Rocker Support 142 Lv7 / T-815 3040 022454 Gear Shift Cylinder Cover 143 Lv7 / T-815 443-311-038-000 Asymetric Head Lamp-891012 144 Lv7 / T-815 130-054-391-354 Rubber Cap 145 Lv7 / T-815 130-054-290-044 Sealing Ring 146 Lv7 / T-815 130-054-300-044 Gasket 0.25 Mm ( 627 834 281 025 ) 147 Lv7 / T-815 130-075-062-644 Connecting Tie Rod 148 Lv7 / T-815 130-071-150-254 Shifter Fork 149 Lv7 / T-815 130-054-170-414 Sealing Ring 130X4, Mvo 75 Digreesh 150 Lv7 / T-815 442-079-250-154 Hydralic Coupling 151 Lv7 / T-815 442-070-211-084 Suction Tube 152 Lv7 / T-815 442-054-032-554 Gasket 0.5 Mm 153 Lv7 / T-815 130-075-190-324 Adjusting Bush 154 Lv7 / T-815 130-072-531-564 Half Axle Lh 155 Lv7 / T-815 130-054-240-034 Sealing Ring H 5009-03 156 Lv7 / T-815 130-071-080-454 Lower Shaft 157 Lv7 / T-815 130-054-032-794 Gasket 0.25Mm 158 Lv7 / T-815 130-076-857-754 Oil Line To Pressure Gauge 159 Lv7 / T-815 130-076-855-594 Line To Trailer Brake Valve 160 Lv7 / T-815 ( Hmv ) 207-506-321-4 Steering Tie Rod 161 Lv7 / T-815 ( Hmv ) 130-076-634-374 Air Venting Accumulator 162 Lv7 / T-815 ( Hmv ) 443-930-159-860 Cover 163 Lv7 / T-815 ( Hmv ) 443-999-100-000 Optical Insert Ii 6002395-131 164 Lv7 / T-815 ( Hmv ) 442-070-220-514 Cooler Body 165 Lv7 / T-815 ( Hmv ) 442-075-064-994 Steering Tie Rod 166 Lv7 / T-815 ( Hmv ) 207-115-021-4 Fork 4.5 167 Lv7 / T-815 ( Hmv ) 442-070-495-000 Ball Joint 168 Lv7 / T-815 ( Hmv ) 207-590-126-4 Exhaust Silencer 169 Lv7 / T-815 ( Hmv ) 207-115-023-4 Fork 2-3 170 Lv7 / T-815 ( Hmv ) 201-722-062-4 Gear Of Speed 2 171 Lv7 / T-815 ( Hmv ) 442-054-390-134 Ball Gear Shift Cover 172 Lv7 / T-815 ( Hmv ) 442-075-901-264 Exhaust Silencer 173 Lv7 / T-815 ( Hmv ) 442-073-150-548 Cross Articulated Shaft 174 Lv7 / T-815 ( Hmv ) 207-020-041-4 3 Stage Oil Pump 175 Lv7 / T-815 ( Hmv ) 443-852-001-000 Pressure Switch Trw 131.684 Ak 176 Lv7 / T-815 ( Hmv ) 207-075-046-4 Fan Shaft ( Ventilator Shaft ) 177 Lv7 / T-815 ( Hmv ) 443-930-159-900 Coil-1 178 Lv7 / T-815 ( Hmv ) 443-400-307-000 Control Light 2X5 955232.001 179 Lv7 / T-815 ( Hmv ) 443-319-014-000 Direction Flasher Switch Over 180 Lv7 / T-815 ( Hmv ) 573-909-020-6 .Prl-0416 Driver Of Shaft Seal 40X52x7 181 Lv7 / T-816 990-200-130-0 Air Cooler 182 Lv7 / T-816 993-100-954-0 Gasket Set 183 Lv7 / T-816 990-100-935-0 Valve 184 Lv7 / T-816 347-222-089-0 Bulb 24V / 70W H3 Pk 22S H3-D 64156 185 Lv7 / T-816 443-811-024-0 Corrector Kpo-26 186 Lv7 / T-816 993-050-333-0 Hose Flexible 187 Lv7 / T-816 993-200-396-0 Harness Assy X238113e 188 Lv7 / T-816 443-414-022-0 Speedometer Vdo 333-055-004C 189 Lv7 / T-816 993-100-324-0 Remote Control 190 Lv7 / T-816 443-400-415-0 Pressure Switch Trw 151.012 191 Lv7 / T-816 443-332-041-0 Mirror 513300.149 192 Lv7 / T-816 443-312-040-0 Rear Combine Lamp, Rh Zkw 891055 193 Lv7 / T-816 272-312-129-0 Reduction Bent Tube Id 70 / 57-90 St Dawson 194 Lv7 / T-816 336-900-025-0 Servo Steering Cylinder V-60-220-02-00Z 195 Lv7 / T-816 993-050-285-0 Hose, Flexible 196 Lv7 / T-816 6240-72-0098608 Lamp Incandescent ( 121223352240 ) 197 Lv7 / T-816 993-050-025-0 Exhaust Pipe Clamp 198 Lv7 / T-816 295-416-124-4 Front Glass Gasket 199 Lv7 / T-816 297-307-531-4 Side Indicator Rh 200 Lv7 / T-816 993-101-183-0 High Pressure Pipe 201 Lv7 / T-816 272-212-051-0 Angular Belt Spa 12, 5X1100gy 202 Lv7 / T-816 443-414-018-0 Oil Thermometer Vdo 310-040-015G 203 Lv7 / T-815 ( Hmv ) 273-521-019-000 Shaft Sealing Ring - Gv 85X110x12 Fkm 40-90 204 Lv7 / T-815 ( Hmv ) 443-853-040-000 Push Button Starting Gear 205 Lv7 / T-815 ( Hmv ) 442-050-811-154 Spacer Washer 1.4 206 Lv7 / T-815 ( Hmv ) 443-743-040-000 Air Cleaner Spp 1500Rs 207 Lv7 / T-815 ( Hmv ) 283-351-005-0 Tube 6X1 Pa 12P56 208 Lv7 / T-815 ( Hmv ) 443-930-159-910 Coil-2 209 Lv7 / T-815 ( Hmv ) 442-950-060-254 Pin 210 Lv7 / T-815 ( Hmv ) 205-311-194-4 Hose 450 Mm 211 Lv7 / T-815 ( Hmv ) 207-016-020-4 Pump Housing 212 Lv7 / T-815 ( Hmv ) 442-965-051-914 Front Apron, Lh 213 Lv7 / T-815 ( Hmv ) 336-152-158-000 Gear Pump Un 16R.64 214 Lv7 / T-815 ( Hmv ) 311-110-920-000 Toothed Washer 5.3 Csn 02 1744.05 215 Lv7 / T-815 ( Hmv ) 324-162-120-080 Ball Bearing 6212 So Csn 02 4630 216 Lv7 / T-815 ( Hmv ) 442-987-300-974 Control Panel 217 Lv7 / T-815 ( Hmv ) 442-987-350-824 Sleeve For Vessel 218 Lv7 / T-815 ( Hmv ) 442-986-480-244 Upper Tie Rod 219 Lv7 / T-815 ( Hmv ) 319-231-408-000 Piston 11461-2 120Mm 220 Lv7 / T-815 ( Hmv ) 443-421-015-000 Voltmeter D60 24V Ganz 221 Lv7 / T-815 ( Hmv ) 442-925-101-444 Bar 222 Lv7 / T-815 ( Hmv ) 442-601-119-000 Screw C / W Neck 223 Lv7 / T-815 ( Hmv ) 106-114-720-000 Hex Head Screw M8x30 Is : 1364 ( Part Ii ) -2 224 Lv7 / T-815 ( Hmv ) 442-076-852-724 Operation Brake Line 225 Lv7 / T-815 ( Hmv ) 442-600-502-000 Spacer Insert 226 Lv7 / T-815 ( Hmv ) 990-100-590-000 Ventilator Shaft 227 Lv7 / T-815 ( Hmv ) 442-076-608-824 Heater To Tannk 228 Lv7 / T-815 ( Hmv ) 442-021-661-684 Steering Lever 229 Lv7 / T-815 ( Hmv ) 442-078-742-324 Front Cover 230 Lv7 / T-815 ( Hmv ) 442-035-260-554 Front Cover Sheet, Lh 231 Lv7 / T-815 ( Hmv ) 442-035-260-564 Front Cover Sheet, Rh 232 Lv7 / T-815 ( Hmv ) 442-075-911-394 Tube 233 Lv7 / T-815 ( Hmv ) 548-241-084-000 Clip Hose - S84 / 15 Sz 234 Lv7 / T-815 ( Hmv ) 278-412-048-000 Exhaust Manifold Gasket Without Asbestos 235 Lv7 / T-815 ( Hmv ) 442-076-634-344 Oil Supply Tube 2Nd Part 236 Lv7 / T-815 ( Hmv ) 136-241-076-000 Hose Clamp - 45 Is : 4762-84 237 Lv7 / T-815 ( Hmv ) 442-070-830-254 Pistion C / W Cylinder 238 Lv7 / T-815 ( Hmv ) 321-841-204-000 Pipe Line Clip 239 Lv7 / T-815 ( Hmv ) 442-986-480-264 Tie Rod Side 240 Lv7 / T-815 ( Hmv ) 442-070-351-364 Connecting Exhaust Manifold 241 Lv7 / T-815 ( Hmv ) 442-053-110-924 Hose - 28 / 38-340 242 Lv7 / T-815 ( Hmv ) 442-076-633-734 Return Oil Tube 243 Lv7 / T-816 ( 10X10 ) 993-101-155-0 Control Unit 244 Lv7 / T-816 ( 10X10 ) 993-100-818-0 O-Seal H2927 245 Lv7 / T-816 ( 10X10 ) 993-050-387-0 Kit Water Pump Repair 246 Lv7 / T-816 ( 10X10 ) 993-100-390-0 Gasket 247 Lv7 / T-816 ( 10X10 ) 993-050-023-0 Gasket Starter 248 Lv7 / T-816 ( 10X10 ) 297-630-013-4 Window Regulator 249 Lv7 / T-816 ( 10X10 ) 309-115-069-0 Screw Imbus 250 Lv7 / T-816 ( 10X10 ) 993-101-051-0 High Pressure Pipe 251 Lv7 / T-816 ( 10X10 ) 993-100-832-0 Needle Roller Bearing 252 Lv7 / T-816 ( 10X10 ) 205-353-001-4 Rubber Element Washer 253 Lv7 / T-816 ( 10X10 ) 993-101-187-0 High Pressure Pipe 254 Lv7 / T-816 ( 10X10 ) 993-100-116-0 Gasket 255 Lv7 / T-816 ( 10X10 ) 993-200-231-0 Solenoid Assembly 256 Lv7 / T-816 ( 10X10 ) 205-028-007-4 Ball Socket 257 Lv7 / T-816 ( 10X10 ) 549-452-021-0 Door Lock Rh 258 Lv7 / T-816 ( 10X10 ) 993-101-167-0 Supply Pump 259 Lv7 / T-816 ( 10X10 ) 207-033-373-4 Hose To Uppper Manifold 260 Lv7 / T-816 ( 10X10 ) 298-932-075-4 Short Mudguard Rh 261 Lv7 / T-816 ( 10X10 ) 294-001-011-4 Front Glass 262 Lv7 / T-816 ( 10X10 ) 993-200-384-0 Sensor 263 Lv7 / T-816 ( 10X10 ) 272-212-050-0 Angular Belt Avx 10X1300 La 264 Lv7 / T-816 ( 10X10 ) 993-101-186-0 High Pressure Pipe 265 Lv7 / T-816 ( 10X10 ) 443-999-243-0 Brake Lining Set Perrot 266 Lv7 / T-816 ( 10X10 ) 993-100-382-0 Tube 267 Lv7 / T-816 ( 10X10 ) 993-100-765-0 Tension Spring 268 Lv7 / T-816 ( 10X10 ) 993-101-097-0 Solenoid Valve 269 Lv7 / T-815 ( Hmv ) 130-076-606-584 Line 270 Lv7 / T-815 ( Hmv ) 130-050-990-854 Covering Sheet 271 Lv7 / T-815 ( Hmv ) 442-076-884-684 Line 272 Lv7 / T-815 ( 8X8 ) 2520 012835 Shifting Sleeve 273 Lv7 / T-815 ( 8X8 ) 442-054-440-164 Rubber Bushing 274 Lv7 / T-815 ( 8X8 ) 5940-72-0084545 Terminal Part ( 130 954 470 284 ) 275 Lv7 / T-815 ( 8X8 ) 2520 012897 Fork 276 Lv7 / T-815 ( 8X8 ) 3110-72-0026929 Ball Bearing ( 112 163 060 028 ) 277 Lv7 / T-815 ( 8X8 ) 3130-72-0258895 Bearing Unit Roller ( 112 921 061 252 ) 278 Lv7 / T-815 ( 8X8 ) 2590-72-0479889 Covering Sheet ( 130 035 320 404 ) 279 Lv7 / T-815 ( 8X8 ) 130-020-030-804 Propeller Shaft Ii 280 Lv7 / T-815 ( 8X8 ) 130-020-460-114 Satellite Pin 281 Lv7 / T-815 ( 8X8 ) 130-050-290-084 Glide Block 282 Lv7 / T-815 ( 8X8 ) 130-031-570-254 Hinge Yoke 283 Lv7 / T-815 ( 8X8 ) 443-936-010-340 Pin To Cover Of Brushes 284 Lv7 / T-815 ( 8X8 ) 130-070-130-164 Crank Shaft Gear Wheel 285 Lv7 / T-815 ( 8X8 ) 442-076-691-664 Switch Coupling 286 Lv7 / T-815 ( 8X8 ) 5365-72-0330251 Spacer Special Shaped ( 442 954 160 204 ) 287 Lv7 / T-815 ( 8X8 ) 3020 015628 Pulley C / W Liner 288 Lv7 / T-815 ( 8X8 ) 4730-72-0262309 Bolt Huid Passage ( 130 053 621 014 ) 289 Lv7 / T-815 ( 8X8 ) 442-076-604-464 Line 290 Lv7 / T-815 ( 8X8 ) 443-960-522-111 Fuel Hose 291 Lv7 / T-815 ( 8X8 ) 3130 000889 Gear Shift Housing 292 Lv7 / T-815 ( 8X8 ) 309-706-141-220 Screw -M12x32 Csn 02 1201 7-10.9 Mks 720 293 Lv7 / Hrv Av-15 153995 Cross Head Pin Complete 294 Lv7 / Hrv Av-15 273-111-010-270 Ring 50X40 295 Lv7 / Hrv Av-15 273-111-014-784 Ring 240X5 296 Lv7 / Hrv Av-15 309-201-180-819 Screw M8x28 297 Lv7 / Hrv Av-15 309-203-180-620 Screw M6x30 298 Lv7 / Hrv Av-15 309-203-181-220 Screw M12x30 299 Lv7 / Hrv Av-15 309-208-180-832 Screw M8x60 300 Lv7 / Hrv Av-15 309-210-000-815 Screw M8x18 301 Lv7 / Hrv Av-15 309-255-420-410 Screw M 4X10 302 Lv7 / Hrv Av-15 309-543-181-232 Screw M12x60 303 Lv7 / Hrv Av-15 309-578-181-014 Screw M10x16 304 Lv7 / Hrv Av-15 311-210-211-280 Washer 28 305 Lv7 / Hrv Av-15 311-215-111-064 Washer 6.4 306 Lv7 / Hrv Av-15 324-622-168-600 Bearing 22216 Bjb Stn 024705 307 Lv7 / Hrv Av-15 324-712-110-000 Bearing 30211 308 Lv7 / Hrv Av-15 324-715-147-400 Bearing 32014X 309 Lv7 / Hrv Av-15 324-717-160-000 Bearing 32216 310 Lv7 / Hrv Av-15 578-003-005-252-15 Hub 311 Lv7 / Hrv Av-15 578-003-030-652-29 Packing 312 Lv7 / Hrv Av-15 578-003-030-952-29 Packing 313 Lv7 / Hrv Av-15 578-003-064-152-62 Washer 314 Lv7 / Hrv Av-15 578-003-069-352-62 Washer 315 Lv7 / Hrv Av-15 578-003-070-252-62 Pressure Hose 316 Lv7 / Hrv Av-15 578-003-102-452-60 Disc 317 Lv7 / Hrv Av-15 578-003-102-652-34 Driving Wheel 1.2 318 Lv7 / Hrv Av-15 578-003-102-752-43 Shaft
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 1
Maharashtra View Result →
29.
Agriculture #10079043 Price Bid
Tender For Supply Of Veterinary Instrument / Equipment / Chemicals / Re Agent / Media Supply Of Veterinary Instruments / Equipments / Chemicals / Reagents / Media , Hematology Auto-Analyzer , 5 Part Veterinary Hematology Analyzer For Veterinary Use Only And Not For Human, With Feature Of Direct Mode To Select The Canine, Feline, Equine, Bovine, Ferret, Gerbil, Rabbit, Pig, Mini Pig And Guinea Pig, Goat, Sheep, Llama, Alpaca, Camel, Dolphin, Based On Laser Flow Cytometry, Optical Fluorescence And Laminar Flow Impedance Technology To Measure All 26 Parameters: Red Blood Cell – Rbc, Hematocrit - Hct%, Hemoglobin - Hgb, Mean Corpuscular Hemoglobin Concentration - Mchc, Mean Corpuscular Volume – Mcv, Mean Corpuscular Hemoglobin – Mch, Red Cell Distribution Width – Rdw, Reticulocyte Count % , White Blood Cell – Wbc, Neutrophils - % And Neutrophils Absolute Numbers, Lymphocytes - % And Lymphocytes Absolute Numbers, Monocytes - % And Monocytes Absolute Numbers, Eosinophils - % And Eosinophils Absolute Numbers, Basophils - % And Basophils Absolute Numbers, Platelets – Plt, Mean Platelet Volume – Mpv, Platelet Distribution Width – Pdw, Plateletcrit Value – Pct, Requiring Less Than 30 ?L Of Anticoaguled Whole Blood, With Other Important Parameters Reticulocyte Hemoglobin, Band Neutrophil And Reticulocyte Count Also, Also To Report For Other Parameters Like Nucleated Rbc, Band Neutrophil Etc If Presence Suspected In Sample, Requiring Two Reagent Kits One External And One On Board, With Results In Two Minutes, Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Standby Mode, External Printer Interface Facility To Get The Printouts With All Parameters Including Dot Plot, Integrate With The Laboratory Information Management System For Analyzer Operation As Well As Patient Information With Patient Records, Us Fda / Ce / Iso Approved , Trinocular Microscope , Trinocular Microscope: Head: Trinocular 30 Degree Inclined W / Photo Tube & C-Mount Eyepieces: Cfi E 10X ( 20Mm ) Objectives: Cfi E Plan Achromat 4X, 10X, 40X, 100X Oil Stage: Mechanical Stage With Slide Holder Condenser: E2 Abbe Condenser N.A. 1.25, Aperture Diaphragm With Position Guide Markings For Respective Cfi E Plan Objectives Focus: Coaxial Coarse / Fine Focus Controls Illumination: Led Illumination Misc: Dust Cover, Power Cord, Manual Warranty: 5 Year Mechanical And Electrical Camera Specifications: Screen ( Optional ) Mountable 11.6 Retina Display Screen ( Hardware Included ) Resolution ( Live ) : 1920X1080 - Captured 5 M.P. Sensor: 1 / 2.5 ( 0.5X C-Mount Recommended ) ; Aptina Mt9p031 Frame Rate: Hdmi ( 30Fps ) ; Usb 2.0 ( 15Fps ) Image Capture: High Speed Sd Card ( 4Gb ) Video Capture: Hdmi: 1080P, 30Fps To Sd Card Usb 2.0: 1080P, 15Fps To Pc Or Mac Exposure Time: 0.001 Sec - 10.0 Sec White Balance: Auto Settings: Gain, Gamma, Saturation, Contraction Built-In Software: Cloud 1.0 Pc Imaging Software: Captavision Imaging Software ( For Pc Only; Mac Os Not Supported ) Advanced Camera Controls: Live / Still Image Measurement And Annotation, Flat Field Correction; Extended Depth Of Focus ( Focus Stacking ) ; Image Stitching; Hdr ( High Dynamic Range ) Function Image Types: Jpeg, Bmp, Tiff And Raw Output Modes: Mode 1: Usb 2.0 / Mode 2: Hdmi System Compatibility: Windows Xp, Vista 7 And 8, And 10 ( 32 Or 64-Bit ) Mac Os X ( For Image Transfer To Mac Os X Only ) System Requirements: Intel Processor ( Core 2 Duo Or Higher ) ; 2Gb Memory Or More; Usb 2.0 Hi-Speed Port Power Supply: Dc12v / 1A , Reinforce Protection Glass 11. Stainless Steel Darkroom 12. 10 Positions Filter Wheel To Be Supplied With The 590Nm Interferential Filter With The System For Ethidium Bromide Application 13. Auto-Exposure, Auto Focus And Automatic Illumination Control 14. The Field Of View Should Be Approximately 21X26 Cm At The Uv Transilluminator ( Slide-Out, Uv 312Nm Excitable ) Level. The Transilluminator Should Be Slide Outdesign. 15. The Uv Transilluminator Is To Be Stained Free Compatible, As Well As For The Most Common Dna / Rna Dyes 16. The System Should Be Upgradable In Future With Up To 6-8 Excitation Channels In The Uv And Visible Area For A Large Array Of Applications Such As Dna Or Rna Gels, 1D Protein Fluorescent Gels, Stain Free Gels 17. A Complete Library That Contains The Excitation And The Emission Spectra Of The Main Fluorophores Used In Modern Molecular Biology Laboratory Should Be A Built-In Feature Of The Software. It Also Should Suggest The Best Possible System Configuration In Terms Of Light Source Excitation, Emission Filter And Sensitivity Level Of Applications To Ensure Reproducibility And Ease Of Use. 18. White Light Conversion Plate Should Be Supplied 19. Facility Must Be Available To Upgrade With Blue Conversion Screen For The Excitation Of The Syber Green And Of The Sybr Safe 20. Suitable Branded Desktop Computer Must Be Quoted As Optional 21. Service Engineer Should Be Available At Bhubaneswar 22. Warranty- 1 Year , Rnase Jap , Steri Sweep Molecular Grade , Petridsih Disposable, 100Mm , Bq Rapid Test Kit , Goat Pox Virus Antigen Rapid Test Kit , Hs Rapid Test Kit , Ppr Virus Antigen Detection Rapid Test Kit , Rd Virus Antigen Detection Rapid Kit , Rotheras Mixture Lr , Super Script™ Iii Platinum™ One-Step Qrt-Pcr Kit Catalog Number:11732020 Molecular Grade , Cryo-Container 3 Litres , ( Capacity-3 To 4 Lts Of Ln2 With Static Evaporation Loss Rate Of 0.135 Litres Per Day At Stp, 6 Canisters With Od 38 Mm, Height 120Mm. The Level Of Ln2 From Bottom Should Be About 20Cm. The Neck Diameter Should Be 50Mm. The Container Is Meant For Private Ai Practitioners & Should Be Sturdy ) , Cryo-Container 35 Litres , ( High Strength Aluminium Alloy Liquid Nitrogen Container, Neck Diameter About50mm, Loss Mass- 0.29 Litre Per Day, Static Holding Time-123 Days ) , Frozen Semen Straw Lifter-10 , Stainless Steel, L Shaped, Designed To Lift Semen Straws With Vertical Serrationsmade At The Tips ( 10’’ ) , Kit Bag, Nylon Fabricated Materials, Water Proof With Good Quality Chain Having Two Main Inside Partitions & One Outsidebox Pocket, With Hanging Handle & Back Carrying Belt, 12 Height, 21 Length, 7 Width, Able To Carry 10 Kg Weight , Burdizzo Castrator For Bull Calf, Made Up Of Stain Less Steel ( 19 Length ) For Bull Calf. Burdizoo Pattern Castrators For Large Animals Consist Of Two Jaws ( Upper Jaw And Lower Cord Stop Jaw ) With Two Levers Coupled With Nuts. Material Carbon Steel Length ( Total ) 19” Width Of Upper Jaws 75 Mm + / - 2 Mm Lower Jaw ( Cord Stop Jaw ) Cord Stop Of 5-8 Mm Ht. On Both Sides ( The Gap On Either Side Between The Upper Jaw And Lower Jaw ( Having Cord Stop ) Should Range Between 1 To 1.5Mm ) Other Requirements:- 1. Tenderer For Imported Castrators Should Submit Proper Letter Of Authority From Their Principals. 2. The Offered Product Should Be In Indian Market For At Least 2 Years. 3. List Of Actual Users To Whom Same Brand Is Supplied Should Be Submitted With Copy Of Ratecontract / Supply Order Etc. 4. The Castrators Should Be Guaranteed For Satisfactory Performance For A Period Of Minimum One Year From Date Of Supply, During Which The Bidder Shall Be Liable To Be Replaced The Castrators At His / Herown Cost, If Any Complaints Are Received From End User. 5. Castrator Should Not Leave Any Gap Between Upper And Lower Jaw During Castration. 6. The Castrator Should Be Supplied Along With Spanner. With The Help Of Spanner All The Nuts Ofcastrators Shall Be Alternatively Loosened And Tightened Five Times And Neither Nuts Nor Jaws Ofspanner Shall Show Any Sign Of Damage Or De Shape. 7 . Name Of Manufacturing Company Should Be Permanently Embossed / Etched On The Body Of Castrator. , Cryo-Container 50 Litres , ( Liquid Nitrogen Container 50L, Neck Diameter About50mm, External Diameter 500Mm, Height 790Mm, Loss Mass- 0.37 Litre Per Day, Static Holding Time-134 Days ) , Digital / Electronic Semen Thaw Unit 475 Ml Capacity ( For Bovine ) , Made Up Of Stain Less Steel, Thermoflax Model With One Side Handle, With Digital Display Temperature, Having A Plastic Canister Inside To Keep / Lift The Semen Straw, With A Power Cable To Heat, Dimension ( Lxwxh ) ( 4.7 X 4.2X 9.5 ) , Weight ( Empty ) -610G, Power-74W, Rated Frequency- 50Hz, Rated Voltage-220V Ac, Capacity-475 Ml , Frenchmini Empty Straw, Pvc Straw Of Different Colours.Pack Of 2000 Straws ( 0.25Ml ) . Total Length 133Mm + / - 0.25 0.5Mm, External Diameter 1.99Mm , Internal Diameter 1.63Mm, 0.25Ml -Low Absorption Alpha Type With Flouroscent Plug Technology For Precise Filling And Safety , Cryo Gloves , Can Withstand To Retrieve The Frozen Semen Straw From Liquid Nitrogencryo Container , Portable Veterinary Ultrasound Machine , 1. It Should Be Portable Veterinary Touch Screen Color Doppler Ultrasound Unit Having Minimum12” Lcd Led Backlit Screen Size And Should Not Be Weighing More Than 4 Kg Includingbattery. 2. It Should Be Meant Forcanine, Feline, Equine, Bovine, Lama, Pig, Sheep And Others And Should Have True Veterinary Software 3. It Should Have Intuitive Interface, Touch Pad And Touch Key Board 4. It Should Have Touch System To Select Imaging Modes Like: B, B+B, Power B, B+M, M, Cfm Andpw . 5. The Machine Should Offer Dual Cfm- B / Cfm, Adjustable Region Of Interest ( Roi ) , 6. Itshould Offer Image Orientation From Left – Right And Up & Down 7. It Should Have Battery Backup For Minimum 3 Hours And Charging Time Should Not Be More Than 3 Hours 8. It Should Have Minimum 2 Usb Connectors, Wi-Fi Compatibility To Send Images To Ipad And Other Smart Devices , Basic Dicom, Stereo Sound And Bluetooth Compatibility . 9. It Should Have Digital Touch Control For All The Operational Features Like- Adjustment Of Tgc, Gain, Brightness & Contrast, Image Orientation, Focus, Freq, Depth And Dynamic Range. 10. It Should Display Mi & Ti Indexing On The Screen By Default And Should Be In The Permissible Limit As Per Fda And Overall Safe. 11. The Machine Should Be Able To Generate Report Of The Animal Combined With Images To Further Send Through Digitally In Multiple Forms 12. The Ultrasound Machine Should Be Offering Absolutely Very High Image Quality Hence Should Be Using Digital Dual Beam Former And Computing And Should Be Using Minimum 128 Reception Channels And Around 60 Emission Channels Or More. 13. It Should Have 500Gb Hard Disc Capacity 14. The Machine Should Offer Both Portrait And Landscape Imaging View 15. The Machine Should Be Having Hdmi And Wi-Fi Compatibility 16. It Should Have 256 Grey Scale 17. The Machine Must Be Able To Take The Voice Command Of The User To Adjust Depth, Probe Frequency, Focus, Gain And Freeze In B Mode 18. It Should Be Provided With One Micro Convex Probe Having 5-7.5Mhz Frequency Suitable For Small Animal Abdomen 19. It Should Be Offered With Endo Rectal Probe Having Frequency Of 5-10Mhz And 600 Mm Footprint Of The Scanning Face Of The Probe For Large Animal Reproduction And Fetal Sexing On Animal. The Endo Rectal Probe Should Be Atleast 2.5 Meter Long. 20. It Should Have Digitized Tgc Upto 8 Adjustable Zones And Should Be Adjustable With Touch Only 21. The Ultrasound Machine Should Be Fully Compatible For Opu Operation On Animal And Offer Ergonomics Applications To Carry Out Ovum Pickup Successfully With Compatible Devices For Future Procurement. 22. The Machine Should Be Supplied In A Hard Plastic Carry Case Having Proper Housing For Machine And Accessories. 23. The Machine Should Have An Ergo Mount Adaptor For Mounting The Machine On Certain Device / Stand. 24. It Should Have Patient, Hospital And Reporting Format. 25. The Machine Should Be Ce Marked. 26. It Will Be Inevitable On The Part Of The Supplying Company To Arrange And Provide Extensive Clinical Training For Two Days On Animals To Teach About Topographic Anatomy Using Ultrasound And Different Applications Of The Machine For Its Ergonomic Purpose By A Qualified Veterinary Specialist At A Common Venue. 27. The Principal Maufacturing Company Of Offered Product Should Have Their Direct Office And Service Centre In India With Good Strength Of Engineers. 28. The System Offered Should Be Warranted For At Least One Year. , Cryo Can -1.5 Ltr, Capacity 1.5Lit, Material : Aluminium , Static Evaporation Rate : 0.05 Lit / Day To 0.1 Lit / Day , Cryo-Container 55 Litres , Capacity 55Lit, Material : Aluminium , Static Evaporation Rate : 0.43 Lit / Day To 0.45 Lit / Day , Jumbo-12, Capacity 47Lit, Canister : 11, Material : Aluminium , Static Evaporation Rate : 0.35 Lit / Day To 0.4 Lit / Day , Liquid Nitrogen Transfer Hose Pipe ( Non Insulated ) -5 Mt, 1 / 2 Inch Nb 5 Mt Long Flexible Non- Insulated Vacuum Hose Along With Gaskate. , Wide Mouth Container ( Storage Vat Of Frozen Semen Straws ) -390 Liters, •Wide Mouth Container Made Of Non-Magnetic Stainless Steel Of Approximate 390 Ltrs Capacity. •Should Have Capacity To Store More Than 3.9 Lacs Straws Of 0.25 Ml ( With Canisters ) •Static Holding Time: Minimum 30 Days •Internal Diameter: Approx. 770 Mm •Empty Weight: Not More Than 200 Kg •Total Weight ( Including Samples ) : Not More Than 520 Kg •Total Height: Max. 1320 Mm •Daily Evaporation Rate Should Be Less Than 10 Ltr. / Day . •Should Be With Temp. Indicator, Low Temperature Alarm, Level Indicator, Low Level Alarm Indicator. •Should Have Option Of Auto Filling & Interface For Remote Monitoring •Heavy-Duty Casters To Provide Mobility Within The Lab. •The Equipment Must Be Quoted With One-Year Warranty Including Installation. The Concern Should Have Experience Of Installing Successfully At Least ( 03 ) Five Such Systems In Cmu Graded Semen Labs In India, For Which Necessary Documents Must Be Attached. The Satisfactory Working Report From The User Also To Be Attached. , 5 Ply Corrugated Card Board Box, Size-355Mm X 305 Mm X30mm , Ss 316 Storage Tank, Capacity-200Liters, With Accessories Ss 316 Storage Tank, Capacity-200Liters, With Accessories •M.O.C Of All Contact Parts : Ss 316 •M.O.C Of All Non-Contact Parts : Ss 304 Type Of Tank : Torispherical Dish End Vertical Tank •Dia: 700Ø / Shell Ht.: 550 Mm •Shell / Dish Thickness: 4 Mm Steam Heating Jacketed Tank Dia.800Mm X 4Mm Thk. •Shell Thickness: 4 Mm - Ss 304 •Tank With Heat Insulation Jacket With Rockwool Insulation - Dia. 900 Mm •Shell Thickness : 2 Mm - Ss 304 •Tank Internal Surface Mirror Polished. • Volume Sensor-1 No • Ph Sensor-1 No Accessories •Temperature Sensor - 1 No. •Steam Inlet Valve3 / 4 - 1 No. •Steam Trap Assembly3 / 4 - 1 No. •Steam Safety Valve With Pr. Gauge 1 No. •Control Panel- 1 No. •Ss 316 Diaphragm Valve, Size:1 -2 Nos •Vent Filter With Electrical Heating, 10 Long 0.2 Micron P7 Pp Cartridge-1 No. •Sight Glass Assembly3- 2 Nos •1 Tc Compound Pr. Gauge With 4 Dial, -1 To 10 Bar Pressure- 1 No. , Non Invasive Multiplexed Biomass Sensor System, Automated, Continuous, Real Time, Multi Vessel Biomass / Od Monitoring With Working Volume Done To 10 Ml, Biomass Sensitive Range Less Than 0.01 To Greater Than 600 Od Units, 12 Mm Diameter , Peristaltic Pump-201Vnotor-Stepper With Motor Torque-10Kg, Rpm- 1 To 200, Tube Size- 1 To 8 Mm, Flow Rate- 0.8 To 1800Ml / Min, Discharge Pressure - 2Bar, Maximum Discharge Height- 10 Litres, Dimension- ( L-325 X W-170 X H-250 ) Mm , Peristaltic Pump-401Vnotor-Stepper With Motor Torque-1 / 6 Hp, Rpm- 20 To 240, Tube Size- 8 To 19 Mm, Flow Rate- 250 To 20000Ml / Min, Discharge Pressure - 3Bar, Maximum Discharge Height- 30 Litres, Dimension- ( L-500 X W-250 X H-400 ) Mm , Absorbent Cotton Ip 500Gm Pkt ( Each ) , 500 Gm, Absorbency Not More Than 10Sec. , Cover Slip -Glass / Disposable, , Circular / Rectangular-100 Nos / Pkt ( 100 Nos ) , Cover Slip -Glass, Optically Clear, Distortion Free Surfac, Circular & Rectangular-100 Nos / Pkt , Cryovial 1.8Ml / 4.5Ml, Pp, Pkt Of 100, Material-Plastic , Disposable Needle-Strile 18 Gauze Needle Indivually Covered With A Cap In Blister Pack ( Each ) , D76 , Disposable Needle-Strile 20 Gauze Needle Indivually Covered With A Cap In Blister Pack ( Each ) , D76 , Disposable Needle-Strile 22 Gauze Needle Indivually Covered With A Cap In Blister Pack ( Each ) , D76 , Disposable Syringe With Needle-Sterile, Graduated, 10Ml With 18 G Needle Packed Individually ( Each ) , Disposable Syringe With Needle-Sterile, Graduated, 20Ml With 18 G Needle Packed Individually ( Each ) , Disposable Syringe With Needle-Sterile, Graduated, 2Ml With 20 G Needle Packed Individually ( Each ) , Disposable Syringe With Needle-Sterile, Graduated, 5Ml With 18 G Needle Packed Individually ( Each ) , Gauze Cloth , 100% Cotton, 90Cm X 16 Mtr ( Each ) , Gauze Cloth 90Cm X 16 Mtr Bandage 10 Cm X 3 Mtr ; 15 Cm X 3 Mtr , Haematocrit Tubes Acc. To Wintrobe, Soda Lime Glass, Straight Rim, Round Bottom, Double Numbered Scale In Red / White Colour, 105 Mm Subdivided In 1 Mm, Outside Diameter Approx. 6.5 Mm, Inside Diameter Approx. 2.9 Mm, In Cartons Of 20 Pcs. , Non -Absorbent Cotton Ip.500Gm Pkt ( Each ) , Pop Bandage 6 , Roller Bandage 10Cm X 3M, Gauze / Cotton, Pack Of 10 ( Pkt Of 10 ) , Roller Bandage 15Cm X 3M, Gauze / Cotton, Pack Of 10 ( Pkt Of 10 ) , Ph Paper , With Universal Indicator 1 To 14 , Glass Slides, Microscopic -Optically Clear, Distortion Free Surface , Bunsen Burner, Gear Type: Natural Gas, Material: Stainless Steel, Btu Output: 1200 Per Hour, Inlet Tube Od: 0.4375 Inches, Height:6 Inches , Digital Balance, Base On Electromagnetic Force Compensation Technology To Match The Highest International Standards . High Integrated Weighing Scale.Internal Adjustments Caliberation: Lb- C3 Type Caliberation. Motorized Internal Built In Weight Caliberation.Lb-C Series. Psas Fully Automatic Time And Temperature Controlled Internal Adjustments.Lb-C Series. Automatic External Caliberationlb-C / Lb Series Balance Protection.Smart Keystop Calliberation. Menu Lock ( Settings Password Protection ) . Overload Protection.Ip54protection Class. Overview: Display : Lcd High Contrast Display With Led Back Light. Large Glass Draft Shield With 3 Sliding Doors For Easy Acess To Items Being Weighted Key Pad Cover With Plastic Protection.. Tare Key Left / Right Sidefor User Friendly.Bubble Level Indication With Adjustableleg Uniform Surface Level.Balance Is Equipped With Rs232 Ouput Interface Connect Balance Pc Or Statistical Printer.Windows Direct Communication.. Usb Interface Optional. High Grade Materialconstruction Protects Against Chemicals And Rough Handling.Application: Piece Counting, Check Weighing , Percentage Weighing, Tantalization., Animal Weighing, Density Determination, Statistics, Custom Weighing Unit Formulation, Below Weigh Hook . Internal Caliberation: Model: Lb224c- Max- 220Gm, D-0.1 Mg, Pan Size-90Mm, Analaytical Balance:220Gm; Lb224c. External Calliberation:Lb224-220Gm D- 0.1 Mg, Pan Size 90Mm , Ai Tray, Stainless Stell 55-60Cm X25-30 Cm , Calf Puller Consist Of Precision Threaded Shaft Of 76 Long In Two Part With Breech Spanner For Pelvic Bones .Frictionjack Fittingwith Leg And Tractionbelt For Smooth Calf Delivery , Spay Snook Hook, Stainless Steel, Blunt 8 Inch Convex , Goblet Holding Forcep ( 18 ) , Stainless Steel, Lock Types Goblet Holding Forcep , Bipolar Thermocuttery Unit, Microcontroller Based Isolated Electrosurgical Generator Having Both Monopolar And Bipolar Outputs Designed For All Surgical Procedures, All Cut Modes Should Be Able To Adjust Output Power Depending On Tissue Density By Less Than 15% Or 5W, Whichever Is Greater. Should Have Three Coag Modes With Maximum Power Of 120W, It Should Have Three Bipolar Modes With Maximum Power Of 70W, The Unit Should Have Two Hand Switching And Two Footswitch Monopolar Outputs And One Hand Switching And Foot Switching Bipolar Output, The Unit Should Have Individual Digital Display Of Power For Bipolar, Monopolar Cut And Monopolar Coag. The Unit Should Not Have Rf Leakage Current More Than 150Ma. The Unit Should Not Have Rf Leakage Current More Than 150Ma. Two Years Of Comprehensive Warranty Including Bulbs Should Be Provided Along With Technical Support. It Should Follow International Safety Standard And Requirement With Ce Certification Or Usfda Approval. Operating And Service Manual Should Be Supplied. , Air Drill, High Speed Air Handpiece: 360, 000 Rpm Variable High Speed Handpiece, Low Speed Air Handpiece: Up To 20, 000 Rpm For Slow Speed Control., Complete Prophy Starter Kit, 3-Way Air Water Syringe: Allows The Operator The Ability To Rinse The Operative Site With A Stream Of Water Or Mist Or Dry / Blow Debris With A Stream Of Air. Foot Pedal Control: The Foot Switch Is A Durable Chrome-Plated Pedal. By Pressing Harder On The Foot Switch It Will Deliver More Power To The High Speed Handpiece Controlling The Speed Easily. , Burdizzo Castrator Small, Burdizoo Pattern Castrators For Small Animals Consist Of Two Jaws ( Upper Jaw And Lower Cord Stop Jaw ) With Two Levers Coupled With Nuts. Material For Small Animals:Material Carbon Steel Length ( Total ) 220-230 Mm Width Of Upper Jaws 42 Mm + / -2Mm Lower Jaw ( Cord Stop Jaw ) Cord Stop Of 5-8 Mm Ht. On Both Sides ( The Gap On Either Side Between The Upper Jaw And Lower Jaw ( Having Cord Stop ) Should Range Between 1To 1.5Mm ) Other Requirements:- 1. Tenderer For Imported Castrators Should Submit Proper Letter Of Authority From Their Principals. 2. The Offered Product Should Be In Indian Market For At Least 2 Years. 3. List Of Actual Users To Whom Same Brand Is Supplied Should Be Submitted With Copy Of Ratecontract / Supply Order Etc. 4. The Castrators Should Be Guaranteed For Satisfactory Performance For A Period Of Minimum One Yearfrom Date Of Supply, During Which They Shall Be Liable To Replace The Castrators At Their Own Cost, If Any Complaints Received From End User. 5. Castrator Should Not Leave Any Gap Between Upper And Lower Jaw During Castration. 6. The Castrator Should Be Supplied Along With Spanner. With The Help Of Spanner All The Nuts Ofcastrators Shall Be Alternatively Loosened And Tightened Five Times And Neither Nuts Nor Jaws Ofspanner Shall Show Any Sign Of Damage Or De Shape. 7. Name Of Manufacturing Company Should Be Permanently Embossed / Etched On The Body Of Castrator. , Drenching Gun, Usage / Application - Drenching For The Entire Herd, Automation Grade / Semi-Automatic, Finishing- Color Coated, Capacity- 23 Ml , Endo Tracheal Tube No 06, Size-6 Inch, Application- Hospital, Steribility- Sterile, Material- Pvc, Color- White Transparent , Endo Tracheal Tube No 08, Size-8 Inch, Application- Hospital, Steribility- Sterile, Material- Pvc, Color- White Transparent , Et Tube ( Size 2-12 ) , Size- 2Mm To 12 Mm, Cuff Type- Cuffed , Hartman Ear Forcep, Composition: Stainless, Customer Segment: Hospitals, Surgery Centers & Tissue Banks, Finish: Satin, Grade: Or, Item Type: Forceps, Length - Working ( Mm ) : 64, Length 1 - Tip / Jaw ( Mm ) : 6, Physician / Developer: Hartmann, Shape: Straight, Therapeutic Specialty: Otology, Usage: Reusable, Width 1 - Tip / Jaw ( Mm ) : 1.5 , Laryngoscope, Battery Handel, Throat Cannual, With 2 Attachment For Anesthesia. , Pm Kit, 1 ) Amputation Saw, Stainless Steel 2 ) Wire Saw With Handle, Stainless Steel ( Gigil Wire Saw ) 3 ) One Spare Wire For Wire Saw4 ) Post-Mortem Knife 5 ) Full Hand Gloves, Size-6 & 7 6 ) Post-Mortem Gloves, Latex, Size-6 & 77 ) Bone Hammer8 ) Bone Chisel9 ) Post - Mortem Scissor, Stainless Steel10 ) Scalpel, Stainless Steel11 ) Allis Tissue Forceps, Stainless Steel 1512 ) Sharpening Stone13 ) Probe, Stainless Steel14 ) Scissor, Dressing, Stainless Steel15 ) Bowel Scissors, Stainless Steel16 ) Retractor Four Prong Sharp 17 ) Retractor Four Prong Blunt 18 ) Dissecting Forceps, Toothed, Stainless Steel 19 ) Bone Holding Forceps, Stainless Steel 20 ) Abscess Knife, Stainless Steel22 ) Bone File23 ) Measuring Tape 24 ) Vice With Two Adjustable Jaws Made Of Iron For Cutting Heads Of Animal. , Small Animal Dental Instrument Set, D107 , Suture Cutting Scissor, Size- 6 Inch, Material- 304 Grade Stainless Steel, Material Grade- Aisi Grade, Automation Grade- Manual, Handle Type- Finger Ring , Opthalmoscope, Technical Specifications Of Opthalmoscope: 1. Dimensions: 5.12” L X 1.40” W X 3.75” H Without Eyecup ( With Eyecup: 1.45” L ) 2. Weight: 48 Lbs Without Eyecup; 50 Lbs With Eyecup 3. Focusing Range: -20 To +20 Diopters Other Features Of Opthalmoscope: 1. First Easy Entry Into Undilated Pupils 2. 5X Larger View Of The Fundus Vs. Standard Opthalmoscopes In An Undilated Eye 3. 25 Degree Field Of View Vs. Standard 5 Degree Field Of View 4. Greater Working Distance Improves Comfort For Both Practitioners And Patient 5. Patented Glare Extinguishment System Prevents Interference From Unwanted Glare And Reflections 6. Halogen Hpx Lamp Provides Bright 7. Compatible With All Existing Welch Allyn 3.5 V Power Sources 8. Digitally Capture, Store And Share Fundus Images By Combining With Eye Examiner For I Phone 4 / 4S, Eye Examiner For I Phone 6 / 6S And Eye Examiner For I Phone 6 Plus / 6S Plus Adapters 9. The Veterinary Pan Opthalmoscope Has A 3 Spot Sizes: Micro, Small And Large With Add On Magnifying Lens 10. One Year Warranty , Automatic Urine Analyzer , Veterinary Urine Analyzer For Veterinary Use Only And Not For Human For Species Canine, Feline And Equine, Based On Urine Strip Reflectance Technology To Measure All Parameters: Ph, Leu ( Leukocytes ) , Pro ( Protein ) , Glu ( Glucose ) , Ket ( Ketones ) , Ubg ( Urobilinogen ) , Bil ( Biliruben ) Single Test Urine Strip To Measure All Above Parameters, Very Light Weight And Not More Than 1 Kg With Calibration Strip For Calibration Of The Analyzer On Fix Frequency, Able To Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Maintenance Free And Ready To Use, Can Be Integrate With The Laboratory Information Management System ( Optional ) With In Built Thermal Printer To Printout All Parameters, Lcd Display For Operating The Analyzer Ce / Iso Approved , Automatic Blood Analyser, 5 Part Veterinary Hematology Analyzer For Veterinary Use Only And Not For Human, With Feature Of Direct Mode To Select The Canine, Feline, Equine, Bovine, Ferret, Gerbil, Rabbit, Pig, Mini Pig And Guinea Pig, Goat, Sheep, Llama, Alpaca, Camel, Dolphin, Based On Laser Flow Cytometry, Optical Fluorescence And Laminar Flow Impedance Technology To Measure All 26 Parameters: Red Blood Cell – Rbc, Hematocrit - Hct%, Hemoglobin - Hgb, Mean Corpuscular Hemoglobin Concentration - Mchc, Mean Corpuscular Volume – Mcv, Mean Corpuscular Hemoglobin – Mch, Red Cell Distribution Width – Rdw, Reticulocyte Count % , White Blood Cell – Wbc, Neutrophils - % And Neutrophils Absolute Numbers, Lymphocytes - % And Lymphocytes Absolute Numbers, Monocytes - % And Monocytes Absolute Numbers, Eosinophils - % And Eosinophils Absolute Numbers, Basophils - % And Basophils Absolute Numbers, Platelets – Plt, Mean Platelet Volume – Mpv, Platelet Distribution Width – Pdw, Plateletcrit Value – Pct, Requiring Less Than 30 ?L Of Anticoaguled Whole Blood, With Other Important Parameters Reticulocyte Hemoglobin, Band Neutrophil And Reticulocyte Count Also, Also To Report For Other Parameters Like Nucleated Rbc, Band Neutrophil Etc If Presence Suspected In Sample, Requiring Two Reagent Kits One External And One On Board, With Results In Two Minutes, Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Standby Mode, External Printer Interface Facility To Get The Printouts With All Parameters Including Dot Plot, Integrate With The Laboratory Information Management System For Analyzer Operation As Well As Patient Information With Patient Records, Us Fda / Ce / Iso Approved , Automatic Urine Analyzer , Veterinary Urine Analyzer For Veterinary Use Only And Not For Human For Species Canine, Feline And Equine, Based On Urine Strip Reflectance Technology To Measure All Parameters: Ph, Leu ( Leukocytes ) , Pro ( Protein ) , Glu ( Glucose ) , Ket ( Ketones ) , Ubg ( Urobilinogen ) , Bil ( Biliruben ) Single Test Urine Strip To Measure All Above Parameters, Very Light Weight And Not More Than 1 Kg With Calibration Strip For Calibration Of The Analyzer On Fix Frequency, Able To Storeall Consumables At Normal Room Temperature And No Refrigeration Required, Maintenance Free And Ready To Use, Can Be Integrate With The Laboratory Information Management System ( Optional ) With In Built Thermal Printer To Printout All Parameters, Lcd Display For Operating The Analyzer Ce / Iso Approved , Otoscope / Auroscope, Otoscope Set , Inverter, Capacity: 900 Va / 12V; Maximum Bulb Load - 756 Watt, Protection: Mcb For Protection From Input Mains & Safety Alarm To Warn In Case Of Short Circuit, Display: Lcd Display For The Status Of Power Back-Up / Battery Charging Time In Hours And Minutes, Inverter Battery Capacity: 80 Ah - 150Ah, Battery Type: Tall Tubular Inverter Battery , Nominal Voltage: 12V; Rated Capacity At 27Oc: 200 Ah , Bench Platform Stainless Steel Weighing Balance ( Capacity 200Kg ) , Calibration- Internal, Weighing Capaciy Upto 200Kg, Material-Ms , Restraining Chain For Dog, Dog Restraint Heavy-Duty Tie-Out Chain Featuring Two ( 2 ) Snap Hooks, Lengths: 3 – 4 Meters, 3-5 Mm, Stainless Stell , Electric Water Heater, Capacity- 25-50 Litres, Max Rated Pressure- 5-10 Bar, Power ( Kw ) -2-4 , Stretcher Trolly For Small Animals, Stainless Steel Stretcher Trolley For Small Animal , Removable Stretcher, Attachment Hooks, Stainless Steel Tray, Possibility Of Integrating A Coloured Carpet With Frame, 4 Retractable Handles As Well As 4 Castors, 2 Of Which Have Brakes. , Muzzel For Dog Restrain, For Dog , Needle Destroyer, Input Electrical Supply- 1Ph, 230 Vac ( + / - 10% ) , 50 Hz ( + / -3% ) , Enclosure- Abs Plastic Injection Molded, Power Consumption- 100 Watts ( Minimum ) In Continuous Rating, Destruction Capacity- Needles Of Size Dia 0.4 Mm To 1.6 Mm, Syringe Cutter- Hardened Stainless Steel Cutter, Collection Tray Capacity- Maximum 200 Nos Of Cut Syringe Hubs & Swarf Of Destroyed Needles. Overall Dimensions- 230 ( L ) X 150 ( W ) X 95 ( H ) Mm. Weight In Kgs: 2.0 Approx. , Pet Hair Trimmer, Low Noise Cordless With 4 Comb Guides Scissors Pet Hair Trimmer , Pet Nail Cutter, Stainless Steel Sharpness Blades, Secure Grip Rubber Coated Non-Slip Handles, Safety Lock Mechanism, Safety Guard , Staining Rack, Designed For The Staining Of Upto 25 Microscope Slides , Travis For Pet ( Squeeze Cage ) , Heavy Duty Metal Cage To Restrain Pet Dog / Cat ( Length-30, Breadth-16, Height-20 ) , Ot Table, Side End Control Ot Table Is Mobile, Hydraulic Designed For Small Animal Surgery. Adjustable Height Functions. The Surface Of The Table-Top Should Beplain And Is Smooth And Easy To Clean And Disinfect. The Base And Column Of The Table Should Be Of High Quality Medical Stainless Steel. Non-Reflecting Surface, Antibacterial & Easy To Clean. Height Adjustment By Stepping Foot Pedal Downward. Lateral Tilts, Trendelenburg, And Are Realized By Handle Manually. Equipped With Drain System. , Ambu Bag, 265Mm With 85Mm Diameter. Volume: 1500Ml Weight: 190G Components: - Connector, Complete, Towards Patient Valve ( 24.3 ) . - Outer Cover ( 24.2 ) - Inner Bag ( 24.1 ) - Inlet Valve For Combined Air And Oxygen: Complete With Silicone Membrane And Tube Connector For The Oxygen Reservoir ( 24.7 To 24.10 ) , Infrared Lamp, Power- 300W-4000W, Voltage- 110V-440V , Instrument Cabinet, Material- Aluminium, Size / Dimension- ( H ) 1800 X ( W ) 900 X ( D ) 400 Mm, Finishing- Polished, Number Of Doors- 2 Doors, Lockable, Thickness- 1 Mm, Handle Material- Aluminium , Nebulizer, Usage / Application- Hospital, Operation Mode- Table Top, Type- Soft Mist Inhaler , Oxygen Cylinder, 10 Lt , Electric Orthopaedic Bone Drill Machine, One Handpiece, One Charger, Two Batteries, One Sterilizing Channel, One Drill Chuck , One Aluminium Alloy Box, Axial Run-Out Of Cincentricity Is Within 0.05Mm, Rotating Speed Of About 1100 Rpm, Rotated Torque 3.3N / M , Bone Cutter, Material- Stainless Steel, Length- 9 Inch, Steel Grade Ss410, Surface Finish- Dull, Working Type- Double Action , Bone Hammer, Bone Hammer- Nylon Faced, Material- Stainless Steel, Handle Material- Fiber Handle , Bone Holding Forceops, Type- Surgical Equipments, Material- Stainless Steel, Size- 150 - 280 Mm, , Cow Anti Kick Bar, Automation Grade- Manual, Weight-1.7 Kg , Electrical Dehorner, Material- Stainless Steel, -With 24 Volt Safety Transformer, -Including Dehorning Tip Ø 18 Mm, -Very High Heat Release , Electrical Plaster Cutter, Blade Size-42.5 Mm And 62.5 Mm, Includes- 1Spanner And 2 Blades , Digital X-Ray Machine , High Frequency X-Ray Machine Suitable For General Radiography. X-Ray Generator: - High Frequency X-Ray Generator Having Frequency Of 110Khz Or More Should Be Provided. - Power Output Of Generator Should Be 4.2Kw. - Radiographic Kv Range Should Be 40 To 120Kv. - Ma Range ( Rad. ) : 110Ma Or More. - Exposure Time ( Rad. ) : 9 Ms To 5Sec. - Mas Range ( Rad. ) : 1 To 200Mas. Control: Attractive And Ergonomically Designed Control Panel With Total Soft Touch Switches For Various Operations. Having Following Functions & Indications. • Machine On / Off Switch • Digital Display Of Kv And Mas. • Kv And Mas Increase And Decrease Switches. • Ready And X-Ray On Switch With Indicators • Bucky Selection Switch. • Stand By And Exposure Release Switch. • Self Diagnostic Program With Indicators For:- ? Earth Fault Error ? Kv Error ? Filament Error ? Tube Head Thermal Overload. • X-Ray On Indicator. • Incoming Voltage Indicator. • Anatomical Programming Up To 216 Pre-Programmed Functions In Which Automatic Selection Of Technical Factors Is Done According To The Body Part Selection. A 2-Step Hand Switch With Dual Action For Exposure Release With Retractable Cord Should Be Provided For Taking Images From A Safer Distance. X-Ray Tube: • Mono-Block Version X-Ray Tube Head Should Be Provided. The Mono-Block Consists Of Stationary Anode X-Ray Tube, H.V. Transformer, Filament Transformer, H.V. Rectifiers And Capacitors, All Immersed In High Grade Oil With High Dielectric Strength. Mono-Block Tube Head Should Be Protected For Thermal Overload. • Manual Lbd ( Light Beam Diaphragm ) With Should Be Provided With Provision Of Auto Shutoff. Stand: Mobile Stand With 4-Wheel Design, Which Ensures Easy Mobility And Steering. The Spring Balance Stand ( With Fixed Tube Head Column ) Should Be Very Light In Weight With Tube Arm, Which Is Very Easy To Maneuver And Allows Smooth Movements Of Tube Head In Vertical Plane. Lead Lined Cassette Storage Box. This Mobile Stand Is Made To Withstand All Jerks While In Use Offering Unparalleled Reliability. Sbm Stand Can Be Easily Moved On Floor And Lock Should Be Provided To Lock Its Movement On Floor. The Equipment Occupies Minimum Floor Area And Is Capable To Be Taken Through Elevators With Ease. Power Requirement: Single Phase 230V, Ac And 50 Hz., 15 Amps With Line Regulation Of ±10%. Other Requirements: • The Company Should Be Iso And Icmedcertified. • The Unit Should Be Approved By Aerb. • The Unit Should Beeuropean Ce Certified From Notified Body. • The Company Should Have A Local Service Center. • The Company Should Have Proven Track Record In Govt. Sector. , Dryview Laser Imaging Film • Blue 7-Mil Polyester Base • Daylight-Load Film Cartridges • 125 Sheets / Cartridge Choice Of Film Sizes • The Dryview 5700 Laser Imager Should Support The Following Film Sizes 14 X 17 Inch ( 35 X 43 Cm ) 11 X 14 Inch ( 28 X 35 Cm ) 10 X 12 Inch ( 25 X 30 Cm ) 08 X 10 Inch ( 20 X 25 Cm ) Automatic Image Quality Control ( Aiqc ) • Should Ensure Consistency From Film To Film • Automatic With No User Intervention Network Connectivity • Integrated Dicom Interface Should Support Printing From Dicom Print Modalitites Network Connection • 10 / 100 / 1000 Base-T Ethernet Connection To Mange ( Should Support Jumbo Frame ) Dicom Sop Classes Supported • Basic Grayscale Print Mangement Meta Sop Class • Basic Color Print Management Meta Sop Class • Presentation Lut Sop Class • Basic Automation Box Sop Class • Verification Sop Class Dimension / Weight • Height: 19 Inch ( 47 Cm ) • Width: 24 Inch ( 61 Cm ) • Depth: 26 Inch ( 66 Cm ) • Weight: 120 Lbs. ( 54 Kg ) Power • 100-120 Vac; 50 / 60 Hz • 200-240 Vac; 50 / 60 Hz Operating Environment • Temperature: 59 To 91° F ( 15 To 33° C ) • Humidity 20 To 80% Rh, Non-Condensing • Magnetic Field < 50 Gauss • Altitude:-100 To 10000 Ft ( -30.5 To 3048 Mts ) User Interface • Simplified User Panel • User Documentation And Languages Supported: - English ( Uk ) - English ( Usa ) , X Ray Flim Viewer, Specification • Luminance: Max 100000 Cd / M² • Film Density: Max 4.0 D According To En 25580 / Astm E 1390 • Control Range: 1 – 100% • Viewing Screen: 225 X 80 Mm ( 10 X 24 Cm ) • Rated Power: 70 W • Power Supply: 90 – 264 V Ac / 24 V • Dimensions: 315 X 62 X 150 Mm • Lifetime Of Leds: 40000 H • Colour Temperature Of Leds: 5000 K • Housing: Anodized Aluminium Profile With Cooling Fins – Completely Closed To The Environment • Viewing Screen: Crystal Glass With 95% Translucency, Thermally Cured, Anti-Reflective Coating
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 10
30.
Educational and Research Institute #9921235 AOC
Supply Of Following Items For Setting Up Measurement And Instrumentation Lab For 4 Year B.Tech In Electrical Engineering Curriculum And Application For University Of Calcutta. , Experimental Set-Up For Calibration Of A Wattmeter Using Dc Potentiometer With Following Features/Items: Regulated Power Supply 2 Volts, 100 Ma To Operate The Potentiometer. Calibrated Electronic Standard Cell Voltage 1.0186 Volts. Regulated Power Supply 0-5 Volts/0.5 Amps With Milliammeter 0- 500Ma For Current Coil Of Wattmeter. Regulated High Voltage Power Supply 0-250 Dc Volts With Voltmeter 0-250 Volts For Pressure Coil Of Wattmeter. A Panel Mounting Wattmeter 0-125 Watt Is Required To Perform The Experiment Galvanometer For Null Balance. A Volt Ratio Box For Measurement Of Higher Voltage. Complete Circuit Diagram With Wattmeter Connections To Be Provided On The Front Panel Of The Instrument. With Standard Accessories , Experimental Set-Up For Low Resistance Measurement Using Kelvin’S Double Bridge With Following Features: Range: 0.2 Micro Ohm To 11 Ohms, With An Accuracy Of 0.05 % Required Accessories: Spot Reflecting Galvanometer. Dc Source 10 A With One Analog Current Meter. Attachment Of 1 Meter Length. Brass Clamp With Terminals For Zero Setting. With Standard Accessories , Experimental Set Up For Unknown Capacitance Measurement Using De-Sauty’S Bridge With Following Specifications: Source: Sine Wave Signal Of 1Khz. The Amplitude Of Ac Switch Indicating Lamp Is Provided On The Bakelite Board. Two Sockets Are To Be Provided For The Output Of Ac Signals. Detector: For Detecting Small Ac Signals In The Output, Null Detector Is Required As In-Built With Digital Display. Circuit Diagram:The Circuit Layout On The Board Is To Be Provided Out To Facilitate Convenient Working. 4 Or 5 Mm Socket Required For Making Connection. Features: R2 --- Three Decade Resistance Dials Having Value 10×1000, 10×100 And 10×10Ohms R1 ---- Single Decade Resistance Dial Having Value 10× 100 Ohms C1 ---- Unknown Capacitor. C2 ---- Two Fixed Standard Capacitors Having Value 0.01Mfd 0.1Mfd (Loss Free) With Standard Accessories , Experimental Set-Up For Calibration Of A 1-Phase Watt-Hour Meter With Following Scopes: • To Adjust & Calibrate A Single-Phase Energy Meter By Direct Loading Method • To Adjust & Calibrate A Single-Phase Energy Meter By Comparing With A Sub-Standard Meter Specifications: • Static Energy Meter Single Phase: Under Test (Local) Duly Mounted, Wired And Terminated • Static Energy Meter Single Phase: Sub-Standard Meter (Isi Mark) Duly Mounted, Wired And Terminated • Voltmeter: Moving Iron Ac Portable Of Class 1.0 Accuracy And Range 0 - 300 V Ac • Ammeter: Moving Iron Ac Portable Of Class 1.0 Accuracy And Range 0 - 10 A Ac • Wattmeter: Dynamometer Type Ac Single Phase, Multi-Range With Current Coil 5 / 10 Amp And Potential Coil 75 / 150 / 300 V Ac • Variac: Variable Voltage Transformer (Portable – Table / Floor Mounting Type With Enclosure) Input: 230V Ac And Output: 0–270V / 8 Amp Ac • Variable Load: Made Up Of 3 Load Resistors Of 70 Ohms / 700 W Each Duly Mounted And Connected / Terminated To Form Different Loads (35 To 210 Ohms) As Per External Connections • Digital Stop Clock: Portable With Start / Stop & Reset Operation • Set Of Necessary 4 Mm Spring Loaded Patch Cords For Interconnections • Detailed Instruction Manual Supply To Be Connected: 230V, 1Phase, 50 Hz, Ac Mains , Experimental Set-Up For Calibration Of A 3-Phase Watt Hour Meter With Following Specifications: • To Adjust & Calibrate A Three-Phase Energy Meter By Direct Loading Method • To Adjust & Calibrate A Three-Phase Energy Meter By Comparing With A Sub-Standard Meter Specifications: Static Energy Meter Three Phase: Under Test (Local) Duly Mounted, Wired And Terminated Static Energy Meter Three Phase: Sub-Standard Meter (Isi Mark) Duly Mounted, Wired And Terminated Voltmeter: Moving Iron Ac Portable Of Class 1.0 Accuracy And Range 0 - 300 V Ac Ammeter: Moving Iron Ac Portable Of Class 1.0 Accuracy And Range 0 - 10 A Ac Wattmeter: Dynamometer Type Ac Single Phase, Multi-Range With Current Coil 5 / 10 Amp And Potential Coil 75 / 150 / 300 V Ac Variac: Variable Voltage Transformer (Portable – Table / Floor Mounting Type With Enclosure) Input: 230V Ac And Output: 0–270V / 8 Amp Ac Variable Load: Made Up Of 3 Load Resistors Of 70 Ohms / 700 W Each Duly Mounted And Connected / Terminated To Form Different Loads (35 To 210 Ohms) As Per External Connections Digital Stop Clock: Portable With Start / Stop & Reset Operation Set Of Necessary 4 Mm Spring Loaded Patch Cords For Interconnections Detailed Instruction Manual Supply To Be Connected: 440 V, 3-Phase, 50 Hz, Ac Mains , Experimental Set Up For Calibration Of An Lvdt Using Screw Gauge With The Following Specifications: Measurement Range 10/20 Mm Excitation Frequency: 2.5 Khz Sensitivity: 10 Mv Dc/ Mm Linear Range: Full Scale Signal Conditioner Output: 0.1 V Dc Or Maximum Displacement Display: 3 1/2Digit Led With Polarity Indicator Micrometer Least Count: 0.01 Mm Inbuilt Regulated Dc Supply Power Supply: 220 V, 50 Hz With Standard Accessories , Experimental Set Up For Temperature Measurement And Calibration Of A Thermocouple Sensor With The Following Specifications: K Type Thermocouple With Digital Panel Meter Output For Monitoring Test Pins For Monitoring At All Stages Mercury Thermometer & Heater 10 Watts (Optional) 3.5 Digit Dpm As Temperature Indicator Interconnection: 2/4Mm Banana Sockets Dc Supply: Built In Ic Regulated Power Supplies 220V±10%,50Hz Mains Operated With Standard Accessories , Experimental Set Up For Calibration Of A Load Cell Sensor With The Following Specifications: Bridge Made Up Of 4 Strain Gauges Mounted On A Specially Alloy Materials Type Load Cell Built In Excitation Voltage For The Bridge 3.5 Digit Ssd For Direct Reading Stain In Kg. Built In Precision Signal Amplifier. Multi Turn Potentiometer For Zero Adjustment. Different Loads To Be Provided For Building Up Of Load. Test Pins For Monitoring At All Stage Outputs. Interconnection: 2/4Mm Banana Sockets Dc Supply: Built In Lc Regulated Power Supplies 220V ±10%, 50Hz Mains Operated With Standard Accessories , Experimental Set Up For Temperature Measurement And Calibration Of An Rtd Sensor With The Following Specifications: Mercury Thermometer And Heater 10W Rtd(Pt-100) Probe With Protect Cover Bridge Circuit For Transducer Differential Amplifier With Feedback Lead Compensation System Sockets To Be Provided To Study The Process To Find Out The Error Rate 3.5 Digit Digital Panel Meter As Temperature Indicator Interconnection: 2/4Mm Banana Sockets 220V, 50Hz Mains Operated With Standard Accessories , Experimental Set Up For Calibration Of A Bourdon Tube Using Dead Weight Tester With The Following Specifications: Instrument Oil Is Sae 10 Or 20 Or Equivalent. Plunger Element Is Clamped In An Ms Block. Block Is The Junction For Screw Assembly, Pressure Gauge And Oil Cup. Valves To Be Used At The Bottom Of The Pressure Gauge And Oil Cup To Control Oil Flow. The Unit Is To Be Mounted On A Base Plate With Three Leveling Screws. Different Known Weights To Be Provided For Calibration Experiments. With Standard Accessories
Contract Date: Apr 01, 2026 Contract Value : 3.00 Lakh
Boards / Undertakings / PSU No of Bidders 1
West Bengal View Result →
32.
Defence #9897001 AOC
Tender For Rep Maintenance Of Dg Sets At Various Water Supply Installation Under Ge (W) Jrc; 1 S&F (in replacement) MCCB 4 pole, 415 volts in the existing panel / location and connection with using aluminum lugs complete all as specified and directed for the following capacity/rating :-(a) MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA 2 (b) 100 amps rating,36 KA breaking capacity adjustable type 3 (b) 160 amps rating,36 KA breaking capacity adjustable type 4 (b) 200 amps rating,36 KA breaking capacity adjustable type 5 M&L Quarterly Maintenance and servicing of DG Sets comprising Prime mover and alternator with accessories, control panel and connected electric circuits with various type of sensors etc including checking lubricating oil, coolent, filters,V-belt, self starter, battery power, gauges and other connected accessories, cleaning of alternator with vaccum cleaner ,attending faults of AMF panels and replacing the defective partsand identifying malfunction of the DG Set (if any) of following capacities complete all as specified and directed.(a)DG Set of capacity 20/25 KVA 6 (b) DG Set of capacity 30 / 40 KVA 7 (c) DG Set of capacity 62.5 / 63 KVA 8 (d) DG Set of capacity 75 KVA to 100 KVA 9 (e) DG Set of capacity 125 to160 KVA 10 (f) DG Set of capacity 250 KVA Note for Item No 5 :(a)Item comprises site visit charges for authorised technician of OEM of DG Set (or) qualified/experienced technician of DG Sets for checking, identifying the functionality of DG Set and will carry out required preventive maintenance work of DG Set and ensure smooth functioning of DG sets and connected works.(b)One Quarterly maintenance will be paid as Each Job.(c)Major spares of DG Set will be measured and paid seperately under relevent item of the CA catered as supply only.(d)Technician will visit each DG Set quarterly for routine checkup/servicing on date fixed (or) as and when required (in case of break down of DG Set).(e)Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the job. 11 Dismantling radiator assembly from the engine of 250 KVA capacity DG sets by disconnecting inlet and outlet connection overhauling / servicing the radiator, descaling and servicing the radiator internally and externally by using chemicals, including soldering the copper tubes and tank etc for arresting leakage, assembling back including necessary welding and with additional bracket as required. refixing, reconnecting and testing for proper functioningcomplete all as specified and directed by Engineer-in-Charge. 12 Ditto all as per item No 11 above but for DG Set of capacity 20/25 KVA 13 Ditto all as per item No 11 above but for DG Set of capacity 30 / 40 KVA 14 Ditto all as per item No 11 above but for DG Set of capacity 62.5 / 63 KVA 15 Ditto all as per item No 11 above but for DG Set of capacity 75 KVA to 100 KVA 16 Ditto all as per item No 11 above but for DG Set of capacity 125 to160 KVA 17 Dismantling of fuel injection pump assembly complete from the engine of DG Sets, servicing, over hauling,replacement ofvalves, washers etc., assembling, calibration, setting for proper function, reassembling and re-fixing all as directed by Engr-in-charge for the following capacity :-(a)250 KVA Gen Set 18 (b)125 to160 KVA Gen Set 19 (c)82.5/100 KVA GenSet 20 (d)75 KVA GenSet 21 (e)62.5/63 KVA Genset 22 (f)30/40 KVA Genset 23 (g)20/25 KVA Genset 24 Disconnecting and taking down out going cables from the DG sets and cutting removing the burnt cable ends and thimbling and refixing back including provision of cable glands and testing complete for thefollowing capacites of DG sets:-(a)82.5to250 KVA GenSet 25 (b)63 to 75 KVA Genset 26 (c)25 to 40 KVA Genset 27 Supply and fixing (in replacement) spin on fuel filter (pre and fine filter) element with O ring of make : Mico/Kirloskar/Ruston for generator set of following capacity :-(a) 20/25 KVA 28 (b) 30/40 KVA 29 (c) 62.5/63 KVA 30 (d) 75KVA 31 (e) 82.5 to 100 KVA 32 (f)125 to 160 KVA 33 (g)250 KVA 34 Supply and fixing (in replacement) Dry type Air filter element Inner and Outer unit as required at site with O Ring of Make : Mico/Kirloskar/Ruston suitable for following capacity DG Set:-(a) 20/25 KVA 35 (b) 30/40 KVA 36 (c) 62.5/63 KVA 37 (d) 75. KVA 38 (e) 82.5 to 100 KVA 39 (f)125 to160 KVA 40 (g)250 KVA 41 Supply and fixing(in replacement) Lub oil filter element with ORing of Make : Mico/Kirloskar/Ruston suitable for following capacity DG Set:-(a) 20/25 KVA 42 (b) 30/40 KVA 43 (c) 62.5/63 KVA 44 (d) 75. KVA 45 (e) 82.5 to 100 KVA 46 (f)125 to160 KVA 47 (g)250 KVA 48 Supply and fixing (in repairs) By pass filter element with O ring of Make :Mico/Kirloskar/Ruston suitable for following capacity DG Set.(a) 62.5/63 KVA 49 Supply and fixing of V-belt suitable for following capacity DG set including removing old unserviceable fan belt all as specified :-(a) 20/25/30/40 KVA 50 (b) 62.5/63/75/82.5 KVA 51 (c)100/125/160 KVA 52 (d)250 KVA 53 Supply and fixing (in repairs) Water Pump Assy suitable for following capacity DG set including removing old unserviceable water pump assy all as specified :-(a) 20/25/30/40 KVA 54 (b) 62.5/63 KVA 55 (c) 75. KVA 56 (d) 82.5/100 KVA 57 (e) 125/160/250 KVA 58 Supply & fixing common rail diesel sensor suitable for 63 KVA DG Set engine (as per sample)Make :Bosch 59 All as per item No 58 here-in-before but for DG Set capacity 75 KVA Make :Bosch 60 Supply and replacement Water outlet and inlet hose pipe from radiator to Engine and backfrom Engine to radiator complete all as specified and directed.. 61 Supply and replacement Lub oil pipe armoured of suitable length and socket of size 15mm dia all as specified and directed. 62 Supply and replacement Anti vibration rubber pad for side radiator. 63 Supply and replacement DC ammeter 12Vof range (-) 30- 0- (+)30 A . 64 Supply and replacement Lub oil pressure guage0 to 10 kg / sq cm. 65 Supply and top up coolent oil. Make : Volvo line / Servo / Castrol 66 Supply and top up engine oil 15W 40 grade.Make : Volvo line / Servo / Castrol 67 Supply and replace battery connecting single core copper cable 16sqmm with battery terminal made of brass with nuts/bolts/washer (as per sample) all as specified and directed. 68 Supply and top up Battery Distilled water. 69 Supply and fixing SMPS battery charger 12V/24V DC including all fixing accessories and re-wiring with suitable size copper conductor FRLS grade PVC insulated two core cabledrawn through PVC conduit not less than 20mm dia as required at site and complete all as specified and directed. 70 Disconnecting, dismantling 12 V battery charging alternator assembly replacing the unserviceable burnt coil assembly, re-assembling, refixing to engine and testing for satisfactory charging of battery complete all as specified and directed. 71 Ditto all as per item No 70 here-in-before but charging alternator capacity 24 Volts 72 Supply and fix (in repair) heavy duty battery 12V, 88 AH, initial charging, filled with required electrolite/distilled water and fixing/connecting with electric connector cable all as specified and directed. Make : Exide Model : Expresss XP800 or equivalent Luminous/Amaron 73 All as per item No 72 here-in-before but capacity 150 AH 74 Supply and fixing (in repairs) AVR (Auto Voltage Regulator) suitable for Gen Set having input voltage 2 phase + neutral sensing voltage 415 output voltage 95V DC, outpur current 4 A DC voltage regulation +/- 1% average volts, over excitation current tripping fuse protection 4A, fast acting and frequency 50Hz for the following capacities :-(a) 20 KVA to 40 KVA 75 (b) 62.5 KVA to 82.5 KVA 76 All as per item No 74above but for DG Set of capacity 160 to 250 KVA 77 Supply and fixing (in repair) Digital DG Controller suitable for any type DG Set of any capacity complete and connecting with existing electrical circuit all as specified and directed.Make :Kirloskar Green ModelKG934V1 or equivalent 78 Supply and fixing (in repairs) Diods set of Main alternator of DG Set of capacity 20 KVA to 62.5 KVA complete all as specified and directed. 79 All as per item No78but for DG Set capacity 75 KVA to 82.5 KVA 80 All as per item No 78but for DG Set capacity 160 KVA to 250 KVA 81 Supply and fixing (in repairs) Contactors coils, existing model andcoil volt-240/415volts, AC 50Hz all as specified and directedMake :Seimens/Schneider/Hager(a) Suitable for 82.5 KVA to 100 KVA AMF Panel 82 (b) Suitable for 160 KVA AMF Panel 83 (c)Suitable for 250 KVA AMF Panel 84 Supply and fixing (in replacement) CT Coil with CT Ratio 100/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 and as specified and directed.Make : NEWTEK or equivalent 85 Supply and fixing (in replacement ) Self Stater Assembly suitable for 63 KVA to 82.5 KVA DG Set and connecting with electric circuit complete all as specified and directed. 86 Supply and fixing (in repairs) fuse unit 12 V DC (as per sample) suitable for DG Set control panel all as specified and directed. 87 Supply and fixing (in replacement) PVC connector (as per sample) suitable for connecting electric circuits all as specified and directed. 88 S&F (in replacement) PVC insulated Single core, 35 sqmm, copper conductor, stranded cable suitable for inter connection of electric network inside panel including provn of suitable size copper thimbles/lugs with nuts, bolts & washers (considered 02 thimbles/lugs per RM) all as specified and directed. 89 S&F (in replacement) PVC insulated Single core, 1.5 sqmm, copper conductor, stranded cable suitable for inter connection of electric network inside panel including provn of suitable size copper thimbles/lugs with nuts, bolts & washers (considered 02 thimbles/lugs per RM) all as specified and directed. 90 S&F (in replacement) On load change over switch 100 Amps, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixingon wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc complete all as specified and directed. 91 All as per item No 90 here-in-before but capacity 160 Amps 92 All as per item No 90 here-in-before but capacity 200 Amps 93 M&L Minor Repair/cleaning of fuel tank, removing sludge, arresting leak using metal paste/sealent or by welding/soldering, replacement of diesel receiver pipe from lock to tank with clamp set all as required at site complete for the following Gen Set :-(a)20/25/30/40 KVA 94 (b)62.5 / 63 / 75 KVA 95 (c)82.5/100 KVA 96 (d)125/160/250 KVA 97 M&L for minor repair to canopy and painting inside/outside area of DG Set 250 KVA comprising engine, alternator, genset panel board and fuel tank and canopy, as per standard approved colour code with one coat of synthetic enamel paint cleaning scrubbing of all surface including writing by paint the SM MES numbers etc all as specified and all directed by Engr-in-charge. 98 Ditto all as per item No 97 above but for the following capacity (a) 20/25/30 KVA Genset 99 (b) 40 KVA Genset 100 (c)62.5/63 KVA Genset 101 (d) 75/82.5 KVA Genset 102 (e)160 KVA Genset 103 Dismantling, removing the self starter, motor from the engine of following capacity DG sets, opening the self starter body and overhauling/servicing, replacement of carbon brushes with holders, contact plates, jumping leads and seals, re-varnishing the field coil, armature, re-assembling, testing for smooth functioning and re-fixing with the engine and connecting complete all as specified and directed for the following DG set:-(a) 40 KVA Genset 104 (b) 62.5/63 KVA Genset 105 (c) 75 KVA Genset 106 M&L asbestos rope 12 mm dia wrapped over the exhaust pipe and painting with heat proof paint of approved colour including taking down the old rope all as specified and directed. 107 Supply and fixing in replacementVolt meter digital type with 01 xselector switch all as specified and directed. 108 Supply and fixing in replacementAmpere meter digital type with 01 x selector switches & CTs of suitable rating complete all as specified and directed. 109 Supply and fixing in replacementLED phase indicator lamp assy RYB 110 Supply and fixing (in replacement) Water separator suitable for DG sets of capacity82.5 KVA to 250 KVA all as specified and directed. 111 All as per item No 110 here-in-before but DG Set of Capacity 25 KVA to 62.5/63 KVA 112 S&F (in replacement) PVC insulated Single core, 35 sqmm, Aluminium conductor, stranded cable suitable for connecting of earth chamber/electric network with DG Set incl required No of suitable size lugs, nuts, bolts & washers etc all as specified and directed. 113 M & L for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground(earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip size 25 x 4 mm as earth lead connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel, GI earth wire will be protected by 15 mm dia GI pipe light grade, watering pipe 20 mm dia GI light grade, GI wire meshed funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of black cotton soil in earth pit upto ground level, PCC chamber recessed for and including RCC cover including all necessary excavation & earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 print and as directed. 114 Supply & laying (in replacement) jointing, testing and commissioning the XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 Volts grade, cross sectional areaSize 50 Sq mm, 3.5 Core including connecting the same with existing panels with required cable glands, thimbles/ lugs as required at site. 115 Excavation in trenches not exceeding 1.5 m deep and 1.5 m wide and getting out in soft/loose soil for laying pipe any size complete all as specified and directed. 116 Cutting of road / hard standing foot path not exceeding 0.30cm wide and 0.6 mtr depth for laying of pipe line including making good with PCC 1:3:6 type C2 complete all as directed. 117 Return, filling in, including spreading leveling watering and well ramming in layers not exc 25 cm in soft soil complete all as spefied 118 Removing excavated material not exc 50 m above and depositing where directed at level not exc 1.5 m above the starting point 119 M&L forsand cushioning in trenches8 cm below the cables and 15cm above the cable all as specified and directed. 120 Supply and laying old size brick, burnt clay building brick sub class (B) for protecting LT U/G cable all as specified and directed. 121 S&F Restricted entry board word mentioned (As per Sample) with PVC/MS sheet frame frame made out of suitable angle iron (four side) front display on flex sheet pasted on PVC/MS shettinternal size 0.6 m x 0.9 mwith fixing arrangement on gate/walls all as specified and directed. 122 S&F Installation Load distribution chart (single line diagram/As per Sample) with PVC frame (four side) with transparent glass protection in front side on card board/ply wood base, internal size 450mm x 650mm all as specified and directed. 123 S&F DG Set diesel tank lock (as per sample) with fixing accessories complete all as specified and directed. 124 S&F DG Set canopy door hinges (as per sample) with fixing accessories complete all as specified and directed. 125 S&F DG Set canopy door lock (as per sample) with fixing accessories complete all as specified and directed. 126 M&L for cleaning of vegetation nearDG sets Area, by surface dressing upto 10cm in depth including removing of grass, small plants of any description and other unwanted materials and levelling complete all as specified and directed. 127 Supply and fixing (in repairs) voltage monitoring relay (VMR), existing model for AMF panels 415 volt, AC 50Hz all as specified and directed. 128 Annual inspection of all lifts from State Lift Inspector/ competent auth nominated by State Govt including TO and FRO conveyance charges per visit. 129 Dismantling of existing coupling assembly between Diesel Engine and Alternator, including removal of worn-out components, cleaning of shafts and coupling hub, and safe handling of parts. directed by Engr-in-charge 130 Supply and replacement of coupling element (flexible/rubber/gear type as per existing make & model), including new bolts, bushes, and hardware as required.directed by engr-in-charge 131 Re-fixing and alignment of engine & alternator (125 KVA ) shafts using dial gauge/laser alignment method, tightening of bolts to recommended torque, and ensuring proper balance.Trial run and testing of DG set under no-load and load condition, including vibration, noise and performance check with submission of test report.and directed by engr-in-charge 132 Dismantling of alternator from DG set ( 125 KVA,75 KVA,100 KVA 160 KVA including safe removal, opening of stator/rotor and preparation for rewinding.Complete rewinding of alternator stator with super-enameled copper wire of suitable gauge, turns, class ‘F/H’ insulation, as per OEM standard, including replacement of slot liners, wedges and insulation materials. Drying & Varnishing of winding with vacuum pressure impregnation / equivalent method, proper baking, and insulation resistance testing.Re-assembly of alternator, alignment with engine, and re-connection with all accessories.Testing and commissioning of alternator under no-load and load condition, including submission of test report (IR value, load test, voltage balance). Note:-All copper wire, insulation, varnish and consumables to be of ISI marked / OEM equivalent quality. • Contractor shall arrange all tools, tackles, manpower and testing equipmentand all directed by Engr-in-charge 133 Supply of Under Voltage Relay (UVR)/Over voltage realy: Suitable for 415V, 3 Phase, 50 Hz system, auxiliary supply 230V/110V AC or DC (as per site requirement). The relay shall be of reputed make (L&T/Siemens/ABB/Schneider or equivalent), with adjustable under-voltage setting (70%–95% of rated voltage) and definite time delay (0.1–10 sec adjustable). Relay shall be housed in suitable case with test certificate and IS/IEC compliance.Installation, Wiring & Testing: Mounting of UVR in existing LT/HT panel, termination with proper lugs/ferrules, wiring through suitable copper control cable, tightening with proper torque, functional testing of relay operation (pick-up/drop-out) and integration with breaker/tripping circuit.Commissioning & Trial Run: Functional testing of complete scheme under simulated under-voltage condition, verification of tripping sequence, and submission of test report.all directed by engr-in-charge Note: • All tools, tackles, consumables, manpower to be arranged by contractor. • All spares & relays shall be new, OEM approved, ISI marked / IEC compliant.
Contract Date: Mar 20, 2026 Contract Value : 24.40 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 3
33.
Educational and Research Institute #9832816 AOC
PROCUREMENT OF MACHINERIES, INSTRUMENTS, TOOLS AND EQUIPMENTS ETC. RELATED TO ELECTRICAL ENGINEERING AND ELECTRONICS AND TELECOMMUNICTION ENGINEERING LABORATORIES AND WORKSHOPS OF MATHABHANGA GOVERNMENT POLYTECHNIC, MATHABHANGA, COOCH BEHAR, WEST BENGAL- 1 ANALOG ELECTRONICS LAB-I (3RD SEM) 2 50 MHz Dual Channel CRO• Automatic Measurements of Signal Parameters like .Pk-Pk, Average, Max. , Min., rms, top etc. Voltages and Frequency, Period,Width,Duty Cycle, Rise Time, Fall Rime • Waveform and Set up storage facility.• Colour Display. • Advanced features like sequential acquisition of up to 1000 trigger events should be possible.• Standard USB Host & Device Connectivity. • Standard 23 Automatic Measurement andMath Function Including FFT.• Education student Lab guide and professor slide set.DETAILED TECHNICAL SPECIFICATIONS:-a)No. Of Channels:2b)Bandwidth :50 MHzc)Maximum Input:400 V (peak ac + dc) d) Sample Rate :1 GSa/sece)Waveform Update Rate : 400 Waveforms/secf)Memory : 16 Kpts/Ch.g)Time Base : 5nsec / div. To 50 sec./div.h) Resolution : 8 bitsi) Display: 5.7 inch Colour QVGA TFT LCD Display.j)Trigger Modes: Force, Edge, and Video, Pulse width.k) Built In Interface : Standard USB 2.0 (Host and Device)l)Power Supply: 230 V AC Supply, 50 Hz. 3 Function Generatori)Itshould be a waveform / function generator which can be upgraded to an arbitrary waveform generator . It may also have the feature upgrade the frequency of operationii) Should have low harmonic distortion and jitter.DETAILED TECHNICAL SPECIFICATION:--• Frequenc : 1Hz. to 20 MHz for Sine , Square and PulseWaveforms and 1 Hz. to 20 MHz. for Noise• No. of Channels: 1• Frequency Resolution : 1Hz.• Amplitude : 1 mVpk-pk to 10 v (pk - pk) in 50 ohms. • Duty Cycle for Pulse : 0.01 % to 99.99 %• Standard Waveforms: Sine,Square,Ramp,Pulse,Triangle,•Operating Modes: Continuous,Modulate,. .• Modulation Types: AM,FM,PM,FSK,BPSK,PWM• AM : Source both Internal & External, Depth 0 to 120 %With 0.01 % resolution.• FM : Source both Internal & External, Deviation 1Hz to 15 MHz• PM: Source both Internal & External, Deviation 0 to 360 deg C.• PWM : Source both Internal & External. Deviation 0 % to 100 %.• Power Supply : 230 v,50 Hz. ac. 4 Digital MultimeterDC Voltage:400mV to 1000V , AC Voltage: 400mV to 1000V,DC Current: 4mA to 10A, AC Current: 4mA to 10A, Resistance: 100 ohm to 40Mohm, Resistance: 100 ohm to 40Mohm,Capacitance: 4nF to 200µF, Duty Cycle: 0.1% to 99.9%, Frequency: 10Hz to 10MHz, Temperature: 20oC to 750oC,Transistor Test: Yes (for NPN & PNP), Diode Test: Yes, Continuing Buzzer: Yes, Power Supply: 9V, Manual and Auto ranging,Display: 4½ Digit 5 To study the V-I characteristics of UJT Trainer kitVariable DC Power Supply 1.2V to 12V/500m,A DC Power Supply for DPM 5V/500m,A UJT (2N2646) UJT Characteristics UJT Relaxation Oscillator with two different Timing Capacitors ,DigitalMeters for Measuring Voltage and Current ,Set of Patch Chords & User Manual 6 To study the input and output characteristics and to find the h-parameters of a BJT for : —(a) C-E configuration,(b) C-C configuration,(c) C-B configurationHARDWARE SPECIFICATIONS :Dual Variable DC Power Supplies 0V to 12V/500mA and0V to 15V/500mA DC Power Supply for DPM 5V/500mAIndependent Base Limiting Resistors - 2 Nos.(low value) Independent Collector Resistor - 1 No. Transistor( NPN Type SL100) .All Inputs/Outputs through 2mm Sockets set with provision of Digital Multimeter for measuring input and output. 7 ANALOG ELECTRONICS LAB-II (4TH SEM) 8 Feedback Amplifier Trainer12 V DC supply with +/- 10%accuracy,configurable circuit,Inbuilt sine wave generator with frequency range 10 Hz to 10 KHz rangeand Amplitude variation 10mV to 4V, NPN transistor. Voltage Series & Shunt and Current Series & Shunt configurable operation. 9 Oscillator Trainer KITi) Hartley, Colpitt ,Wien Bridge Oscillator Trainer kit : i) NPN Transistor ii)On boardoscillator section,separate tank circuit (iii)Biasing Voltage :+12 V , -12 V ,+12V SMPS Adaptor provided with the trainer for power supply.Designed by considering all the safety standards. Provided with an extensive manual.Power Supply to Kit: 230VAC,50Hz, All interconnections are made using 2mm banana Patch cords 10 To determine the following characteristics of op-amp: —a) input offset voltage, b) slew rate, c) non-inverting gain, d) inverting gain e) adder, f) subtractor, g) differentiator, h) integratorandi) voltage followerTo adjust offset null, setup the closed loop amplifier using IC741 op-amp also to (a) dc gain (b) ac gain. The set complete with +/-12V DC regulated power supply with milli voltage source, Null arrangement and 2V/20V dual range digital voltmeter , In built sine wave,triangular wave & square wave Generator of1 KHz, 15V Vpp (approx.), DC Power Supply : 0 - 5 V (vary through (2No.) rotary switch for specific voltage level 11 DIGITAL ELECTRONICS LAB (3RD SEM) 12 Complete setup to implement encoder, decoder ,multiplexer andde-multiplexer5V D.C. at 100mA, IC regulated power supply,21 Input Switches for data input,IC For Multiplexing 74150 is provided on board with Combinational Circuit, IC For Demultiplexing 74154 is provided on board with Combinational Circuit, One Not Gate is provided on board using 7404 ,16 Output LEDs with driver circuit to observe the output of Multiplexer Demultiplexer, A Pulser to provide the pulses manually for triggering,230 V ±10% at 50 Hz A.C. Mains,necessary patch cords and user mannuals. 13 Complete setup to design / construct parity generator, checker andcomparatorDC Regulated Power Supply 5 VDC/150 ma,5 SPDT switches provided for selecting logic ‘1’ & logic ‘0’,2 output indicators,Sufficient no of 4mm Patch Cords for Interconnection,Power Cords 230v, 50Hz,necessary patch cords and user mannuals. 14 Complete setup to design / construct binary synchronous and asynchronous counterTrainer kit for binary Synchronous and Asynchronous counter. with power supply, display unit, patch cords, manuals and necessary IC. 15 Digital I.C TesterUniversal IC tester: 40 pin DIP ZIF socket, 50 cherry keys Key pad and 16 X 2 LCD Display, suitable for testing of Analog IC, Digital IC and 7-segment display. 16 A/D & D/A Converter TrainerFEATURESAnalog To Digital Converter• 8-bit descrete ADC•12-bit monolithic ADC IC•On-board signal generator with adjustable amplitude levels•On-board LED bank to observe digital outputs•Power supply : +5V, ±12V GND•Interconnection is provided by 2mm connectors•Experimental manualDigital To Analog Converter•8-bit binary weighted resistors DAC•8-bit ladder type D to A converter•8-bit D to A converter using monolithic IC•Simple construction using Op-Amp and resistors•Onboard switches are provided for digital pattern generation•8-bit digital inputs ranges from 00 to FF•Variable frequency counter to study the settling timeSPECIFICATIONS•8-bit binary weighted and 4-bit ladder type DAC are constructed using discrete components•8-bit monolithic DAC having settling time in the range of ns, wide power supply range, low power consumption, full scale error ± 1LSB•8-bit digital ramp ADC constructed using discrete components•12-bit monolithic ADC having conversion time in the range of μs, industry standard pin out, wide input range•8 onboard switches to provide digital inputs to DAC•8-bit counter running on external clock frequency to study settling time of DAC• Built inlow frequency clock generator•1 KHz sine wave with adjustable amplitude level•Onboard variable DC voltage source for studying unipolar and bipolar modes of ADC •12 output LEDs to observe ADC outputs•ADA operates on DC power supply (+12V,-12V,+5V and GND)•Interconnection is provided by standard 2mm connector•Extensive experimental manual is provided with the kit EXPERIMENTSAnalog To Digital Converter• To study and measure resolution of ADC•To measure the conversion time of the ADC•To study full scale adjustment for unipolar and bipolar signals•To study the working of ADC 17 NETWORK ANALYSIS LAB ( 3RD SEM) 18 To study the series and parallelresonant circuitIndependent Resistors - 3 Nos. ,Independent Capacitors - 3 Nos.,Tapped Inductance. All Inputs/Outputs through 2mm Sockets Set of Patch Chords & User ManualWITH SIGNAL GENERATOR, COUNTER, DIGITAL METERS FOR INPUT & OUTPUT and user manual 19 To test and to measure the cut –off frequencies of the following: —(a) constant k-type low pass filter;(b) constant k-type high pass filterTwo Independent Passive LC Filter Networks (LPF & HPF) All Inputs/Outputs through 2mm SocketsSet of Patch Chords & User Manual 20 To study standing wave pattern for a transmission line of finite length with:(a) open termination,(b) shorted termination andmatched termination. 2.To measure the attenuation constant and phase shift constant for matched terminationTransmission Line Trainer Features:* 30-300 Mhz sweep source with detector* Calibrated attenuator* Displays standing waves/maxima-minima on CRO* Uses actual coaxial lines rather than simulated ones.* Impedance matching.* Measures VSWR, reflection coefficient, characteristic impedance, velocity of propagation, dielectric constant and signal attenuation in TDR.* Measure parameters of 50, 75 and 300 Ohms cables* Study Time Domain Reflectometry.* Study location and nature of discontinuities,Open/short, mismatched terminations, etc.* Offers a complete view of the transmission line in analog and digital domains, which is essential for complete understanding of transmission line behavior.Technical Specifications:A. Frequency Domain AnalyzerFrequency range : 30-300 MHz typical LCD Display. Level : 100mV p-p Attenuator 50 Ohms : 0.5, 1, 2,4, 8,15 dB,Output Impedance : 50 Ohms Scope out : X-Y output to scopeB. Resistive Impedance Analyzer ,Characteristic Imp. : upto 800 ohms ,Display : LCD C. Time Domain ReflectometerPRR Short range : 10MHz typical,Pulse width : <10ns typical, PRR Long range : 100KHz typicalAmplitude : 1V nominal, Output Impedance : 50 OhmsAccessories:Lengths of 50 ohms and 75 ohms coaxial cable, 300ohms, parallel line, lossy line, Tee connectors, ,Standard load of 50and 75 ohms, Various capacitive and inductive loads, shorts, Balun 1:1 & 1:4, Operating manual, Mains cord 21 COMPUTER PROGRAMMING LANGUAGE LABORATORY (3RD SEM) 22 Computer Programming Language LaboratoryTURBO C++ Software 23 MICROPROCESSOR LAB (4TH SEM) 24 8085Microprocessor Trainer KitHigh performance 8085A CPU operating at 3 MHz.16 K powerful monitor FIRMWARE expandable to 32 K. 64 K user RAM. Expanded RAM accessible using bankWrite protect facility for RAM. 3.6 V Ni-Cad battery back up. Versatile Keyboard/Display controller using 8279. 24 highly reliable dual function keys. 6 digit seven segment LED display.Parallel I/O lines available through two 8255 chips. Serial I/O through 8251 USART, with on-board level shifters 1488,1489.Programmable communication parameters. Built-in audio cassette interface.3 channels of 16 bit timer/counters from 8253.Powerful 8085 interrupt capabilities. On-board EPROM programmer with ZIF socket for programming 2716 to7512 EPROMs and various EEPROMs. Normal and intelligent programming modes.On-board ADC,DAC, opto-isolator, reed relay and miniature speaker. On-board logic probe.Single stepping, break pointing and machine cycle single stepping facility. Monitor functions can be called through software interrupts. Large collection of application software provided. All address, data and control lines from the CPU, buffered and brought out on 50 pin connector. Additional Stepper motor of specification:Shaft type: 5 mm DCurrent rating: 1200 mA2Voltage rating: 4 VHolding torque: 44 oz·inSteps per revolution: 200Resistance: 3.3 Ohm2Inductance per phase: 2.8 mHNumber of leads: 6Lead length: 30 cm 25 Microprocessor 8086 Trainer KitINTEL 8086CPU AT 4.77 MHZ CLOCK SPEED,16KB for monitor EPROM upgradable to 64kb16KB RAM expandable to 64KBBattery backup provision for RAM upto 64KB16 x 2 (or) 20 x 4 Alphanumeric LCD display101 keys IBM compatible keyboard24 TTL I/O lines brought out to two nos., of 26 pin FRC connector1 number of standard RS232C compatible serial port brought out to a pin D type male connector.3 channel 16 bit counter/timer using 8253.Fully buffered address data and control signals terminated at a 50 pin header(VXT BUS) for interfacing VBMB seriesof experiment boards and bus expansion.8 no’s of interrupt lines are terminated at a 10 pin connector.Kit operates with a single +5V/DC supplyThe kit and the power supply are mounted on a attractive light gray color fiber glass cabinet with fiber glass top cover.Built-in line assembler & DisassemblerPowerful debugging monitor to develop user program. 26 ELEMENTARY COMMUNICATION ENGG. LAB 27 To study the amplitude modulation and demodulation Ttrainer kit Features of Amplitude Modulation and Demodulation Trainer:On-board message signal with variable Amp/Freq On Board carrier signal with variable Amp/Freq AM Modulation using MC 1496 IC Demodulation using Diode Detector and LPF,6th Order LPF,Op Amp Based Variable AmplifierInternal Power Supply +5V , +12V/ 500 mATechnical Specification :Message Signal:Sine wave Frequency 100 Hz to 2.8 KHz, Amplitude 0 to 3VCarrier Signal: Sine wave Frequency-28 KHz to 108 KHzAmplitude 2V,Modulation : Balanced ModulatorAmplifier : Op Amp BasedDemodulation : Diode Detector & LPFLow Pass Filter : 6th Order LPFSupply Voltage (Board) : +12V, +5V / DCSupply current : 100 mA (Minimum)Input Voltage : 230 V/ 50 Hz ACInterface connectors : 2mm socket 28 AM/FM Radio Receiver kitFrequency range: 400KHz ~ 1.5MHzIntermediate frequency: 455KHzInputs: RF signalOutput IF frequency: 455KHz adjustableIF filter: Dual tune LC, RF amplifier with variable gain ,Mixer (frequency converter),Local oscillator:Output Signal: Sine waveFrequency range: 400KHz ~ 1.5MHz ,Amplitude: Adjustable from 0Vpp ~ 2VppOutput impedance: 50 Ohm ,1st and 2nd IF amplifierCentral frequency: 455KHz, Load impedance: Variable R-L-CGain: 40db with automatic gain control, Diode envelope detectorDetection of the envelop with variable RC filter. Audio output:Amplifier with audio jack, Audio amplifier gain: 26Db, Receiving media :MW coil antennaFM radio receiver, Reception range: 88MHz ~ 108MHz with continuous tuningTuning circuit: Using GANG capacitorIntermediate frequency: 10.7 MHz with ceramic filterEXPERIMENTS:Study of double sideband AM reception using envelope diode detector,Study of single sideband AM reception using product detector,Study of image frequencies,Study of adjustment of receiver tuned circuits,Voice reception using DSB/ SSB AM receiver (super heterodyne receiver)Effects of switch faults FM detection output level: 77.5Vrms (typical)FM detection output distortion factor: 0.3% (typical)Audio amplifier: Gain up to 46DbReceiving media: Adjustable telescopic antennaPower supply: -12V,+12V,+5V,GNDOutput volume regulation, output load impedance of 8 OhmEXPERIMENTS AM radio receiverTo study AM radio receiverTo study of image frequencies for AMFM radio receiverTo study FM radio receiverTo measure the frequency response of Audio amplifier 29 Pulse code Modulation and Demodulation system trainerInbuilt variable DC and 1 kHz AC Modulating Signals, Facility for applying external AC or DC Modulating Signal, Modulating circuit consists of a Positive Clamper, Sample and Hold (S and H), Analog to Digital Converter (ADC), Parallel to Serial Converter and Control Signal Generator, Observation of binary coded analog information by the LED status for both Modulation and Demodulation, PCM Modulation technique using IC, Built-in Pulse Code Demodulation circuit using a Serial to Parallel Converter and Parallel Shift Register DAC, Low Pass Filter for both AC & DC, Observation of Modulated & Demodulated waveform, Provision to monitor output on CRO, Clock to be provided from the Pulse Code Modulator to Demodulator circuit, Built-in IC based DC Regulated Power Supply with indication for power ON & fuse, 4 mm Patch Cords – 4 nos, Supply required 230V, 50 Hz and 1 phase AC, Comprehensive instruction manual complete with theory and operating details. 30 Frequency Modulation andDemodulation kitFM Modulators :Audio Oscillator : Sine wave (10Vpp adjustable) Frequency (300 Hz - 3.4 KHz) FM Modulators : 3 nos. • Reactance Modulator : Carrier Frequency - 455 KHz (± 3KHz) Varactor Modulator : Carrier Frequency - 455 KHz (± 2KHz) VCO Based Modulator : Carrier Frequency - 10 KHz - 200KHz (adjustable) ,Mixer / Amplifier adjustment FM Demodulator:Detuned Resonant DetectorQuadrature DetectorFoster-Seeley DetectorRatio DetectorPhase-Locked Loop Detector (IC HEF4046 based)Phase-Locked Loop Detector (IC LM565 based), Low Pass Filter : 3.4 KHz Cut off Frequency Amplifier (with adjustable gain) 31 DPCM & ADPCM MODULATION / DEMODULATION KITDPCM & ADPCM MODULATION / DEMODULATION KITOn Board Signals:. Frequency: 500KHz, Amplitude: 0 to 4 v pp 32 CONSUMER ELECTRONICS LAB (4TH SEM) 33 Black & White TV Trainer kit with provision of fault findingSystem: CCIR-B, 625 lines, Power supply :230V Ac, 50 Hz, Regulation range170v Ac to 270v Ac.,Power consumption :70 watts,Gain Limited sensitivity:55 dB for Video & 25 dB for AudioSound output :2.0 watts maximum. Screen size :20 Diagonal. Channel :VHF 2 to 12, UHF 21 to 68,S-band and Hyper-band. Isolated shockproof chassis. Sections:Electronic tuner, VideoI.F Section, Sound I.F, Video amplifier, Horizontal oscillator, Horizontal driver and EHT, Verticaloscillator, and output, S.M.P.S power ,Controls: Volume, tone, Brightness, contrast. Distortion :10 to 15% in Live program due to expanded P.C.B. All parts are soldered on Tags on SINGLE PCB of size 19x15” with complete circuit diagramSCREEN PRINTED in different colors with FAULT CREATING FACILITIES to create more than 25 faults. Standard Accessories : 1. Frame with PCB mounting.2. Picture tube fitted in wooden cabinet 3. A Manual having 20 practical. 34 DTH TV and SET TOP BOX TRAINER KITPower supply 230 V ,50 Hz, Input frequency: KU Band, Output frequency: 950-1450 Mhz.Noise temp: 35 degree,DISH ANTENA ,LNBIF FREQUENCY: 70 MHz 35 Colour TV Trainer with provision of fault findingStandard : CCIR-B-PAL-G, 625 Lines Channels : 230, 2 - 4 VHP I (VL), 5 - 12 VHP III (VH), 12 - 100 : BAND IV & V, else : S BAND & HYPER BAND Picture Tube Size : 36 cms. Diagonal RF Input Impedance : 75 W (Ohm) 36 DIGITAL & MICROWAVE COMMUNICATION ENGG. LAB 37 Spectrum AnalyzerFrequency range:9 KHz to 26.5 GHz,Phase noise :-102dBc/Hz, Max third order dynamic range, 1 GHz: 111dB, Displayed average niose level,1GHz:-163dBm,Standard attenuator range/step:50dB/10dB,70dB/10 squaredb,Overall amplitude accuracy:+/- 0.50dB 38 Antenna Trainer 86 - 860 MHZSPECIFICATIONS:Radiation pattern plotting software• Stepper motor controlled receiver stand.Antenna Measurement System:RF Source•Source types :PLL Synthesized with integrated VCO• Frequency range :100MHz to 3GHz• Dynamic range :85dBm• Transmitted power min:-50dBm• Transmitted power max:+5dBm • Impedance :50W / SMA RF Detector• Detector type: logarithmicdetector• Frequency range : 1MHz to 8GHz• Resolution: 0.1dB• Dynamic range : 85dB (±3dB)• Noise level : -90dbm• Impedance: 50W /SMA• Representation of RF level : dBmDisplay•128x64 Graphic LCD Display with backlit. Keypad•15 Key Membrane Keypad for user entry.Stepper motor controller•1.80 Resolutions.List of Standard 22 Antenna Suppliedwith the setupWire Antenna1.Monopole Plane base ground2.Dipole (2nos.) 3.Yagi4.Folded Dipole 5.Vee Dipole6.Rectangular Loop 7.HelicalMicrostrip Antenna 1.Planar Dipole 2.Planar Monopole3.CMSA 4.TMSA5.2X1 ARRAY 6.Annular ring7.Chip Antenna8.RMSA9.RMSA- Circular PolarizedAperture Antenna 1.E- Horn2.Open ended Waveguide Rectangular Array Antenna 1.Broadside Array2.Collinear ArrayReflector Antenna 1. Corner reflectorSOFTWARE• Radiation pattern plotting and analysis software suitable for windows environment Antenna PositionerThe Transmitter and Receiver Antenna stand is made of special material which is inhert to EM frequency and it has engraved height and angle scale on It. It has facility to adjust the height and level. Universal plug and fix Antenna mounts are provided to hold the antenna assembly in vertical and horizontalorientation for co and cross polarization.ACCESSORIES • SMA (M) to SMA (M) 50W flexible cable : 02nos• USB cable ( Male A to Male B): 01no• 3 Pin 6 Amp Power chord: 01no • Manual : 01no • Software on CD: 01no EXPERIMENTS• Measure the variation of field strength /inverse square law• Prove the reciprocity theorem of antenna• Plot Radiation pattern of WIRED Antenna Omni directional antenna• Plot Radiation pattern of all Aperture Antenna• Plot Radiation pattern of all Reflector Antenna• Plot Radiation pattern of all Array Antenna• Measure co-polarization, cross polarization 39 Microwave Test Bench (KLYSTRONBased)Klystron Power Supply: Specifications:Input Voltage -230V+/- 10%, 50Hz AC, Beam supply- Voltage:200-450V continuously variable; Current:Regulation: better than 0.5% for +/-10% variation in mains supply voltage; Ripple: less than 5mV rms ,Repeller Supply -Voltage:-10V to -270V continuously variable with respect to klystron cathodeRegulation: better than 0.25% for +/-10% variation in mains supply volt , Heater Supply - 6.3V DC (regulated)Modulation- Square Wave : Frequency 500Hz to 2000Hz; Max. Amplitude- +110V peak to peak, Amplitude and frequency continuously variable; Sawtooth- Frequency 50Hz to 150Hz; Max. Amplitude- 60V peak to peak, Amplitude and frequency continuously variable.VSWR Meter: (Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Power : 230 Volts AC, 50Hz, mains supply) 40 ASK / PSK / FSK Modulation And Demodulation KitFEATURES•VLSI based design •Separate component and operational area •Acrylic cover for component safety •Modular organization of circuit functions •Test points to access signals at every stage of circuit operation •Multimedia based interactive e-manual Data Simulator: Onboard 8-bit variable NRZ-L pattern,Crystal Oscillator: 32.768 MHz,Data Clock: 256 KHz,Data Format: NRZ (L),Onboard Carrier Sine Waves : 1MHz (0°), 1MHz (180°), 500 KHz (0°),Power Supply: +12V, -12V, +5V, GND. 41 Microwave Test Bench (GUNN Based)Gunn microwave test bench:Gunn Power Supply (0 - 12 Volts variable,1 Amp. Max,Modulation Frequency: 1KHz +/- 10% (900-1100 Hz),Output Connector: BNC(F) for Gunn Oscillator & TNC(F) for Pin Modulator,Modulation: Square Wave, Frequency : 500Hz to 2000Hz)• Gunn Oscillator • Isolator• PIN modulator• Variable attenuator • Detector Mount• SWR meter(Sensitivity: 0.2 micro Volts at a 200 ohm input impedance for full scale deflection, Noise level: At least 5 dB below full scale at rated sensitivity and maximum, bandwidth with input terminated in 100 ohms and 500 ohms for low and high respectively, A/C output : BNC Connector for amplified output, Frequency : 1000Hz +/- 10%,Powe : 230 Volts AC, 50Hz, mains supply) 42 1 GHz spectrum Analyser1 GHz spectrum Analyser with tracking generatorFrequency range: 150 KHz to 1000 MHzFreqency Resolution: 1 KHz CF entry 40 Hz sweep resolution at 2 KHz per Division,Frequency Display: 61/2 digitFrqency Control: Digital Phase LockResolution Bandwidth: 3 KHz, 30 KHz, 220 KHz, 4 MHz. 43 INDUSTRIAL ELECTRONICS LAB -I (5TH SEM) 44 Trainer Kit to study Reverse Recovery Characteristics of Power DiodesThe single Board trainer Kit should contain IC Regulated Power Supply, Different types power diodes, Digital Ammeter and Voltmeter and other necessary passive components 45 To study drive circuit of SCRIsolated 230 V/40 W AC Power Supply1.2 V to + 15 V/500 mA DC Power Supply* 0-18 V/500 mA,50 Hz, AC Power Supply* Variable frequency triggering pulses* DC Gate signal control, Pulse gate signal * Synchronous AC gate control signal through DIAC* UJT Triggering* 10:1 On- board resistive attenuator * Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 46 To study a single phase rectifier—output waveform with phase control circuitTrainer Kit to study Single Phase Full wave Bridge Rectifier for fixedDC output, Half Controlled and fully controlled rectification facilities with R and RL, loads 1000 Ohms 10 Watts, 14 ma @ 0.05 A inductive loads.The Single Board Trainer Kit contains :(i) Source for rectification of 4 to 24 V DC fixed and variable output @ a max of 500 ma helps to construct and study Series and Parallel resonance Circuit.(ii) Four Diodes and 4 SCRs in bridge configuration with gradual firing controls and necessary capacitive, inductive and Pie filter components.(iii) Digital Ammeter and Voltmeter. 47 To study a polyphase rectifierIsolated 230 V/40 W AC Power Supply Isolated stepped down 3 PH supply. * 3 Phase diode rectifier in open condition*Provision for Load& CRO output.* Electronic phase sequence finder.*Set of Patch Chords & user Manual 48 INDUSTRIAL ELECTRONICS LAB-II (6TH SEM) 49 Servo Regulator Stabilizer Study Kit500VA Servo stabilizer , 2 Amp Variac, Digital input & output meters, Lamp load, Set of Patch Chords & userManual. 50 To study a Jones chopperIsolated 230 V/40 W DC Power Supply, + 5 V/500 mA DC Power Supply* SCR Jones chopper* Gate firing pulses for Jones Chopper* 10:1 On-board Resistive Attenuator* Provision for 40 W Lamp Load* Set of Patch Chords & userManual. 51 To study speed control of induction motor by voltage and frequency variationV/F CONTROLLER 1 HP, AC SQ. CAGE IND. MOTOR 1 HP,DIGITAL VOLT & AMMETER. 1 PHASE I/P & 3 PHASE O/P,3 PH & 1PH MCB PROTECTION 52 To study the speed control of DC motor by:(a) varying field current keeping armature voltage constant; and,(b) varying armature voltage keeping field current constant DC SHUNT MOTOR (FULL COPPER WINDING) .5 HP WITH BASE MOUNT FRAME 1 No VARIAC CONTROLLED 2 DC POWER SUPPLY ( 1 FOR FIELD & 1 FOR ARMATURE)DC VOLT & AMMETER DIGITAL………4 NosPANEL MOUNTED RPM METER………1 No.WHITE BAKELITE FRONT WITH CONN. DIAGRAM & WOODEN SAFETY BOX.METAL FRAME TABLE (Ply board with sun mica) CUM STAND FOR PANEL 53 Power Electronics Devices Trainer KitShould have Built in power supplyDC supply : +/- 12V, 500mA,Power supply 17V / 750mA,Regulated 13.5V/3A O/P mustbe provided as 12V Battery charging supply. Isolated DC supply +12V/ 300mA with isolated common.On board Inverter transformer of Primary : 230V & Secondaries 12-11-0-11-12/3AOn board Lamp load of 15W (100W) should be provided.AC supply : 230V AC line voltage must be made available on two banana 4mm socketsMust have Two pulse transformers of 1:1:1 are provided for isolation & supplying firing pulsesalong with required DC Power supply to experiment panel under test through 15 pin female ‘D’connector.R-L-C Load PanelMust have Load resistor of 10W / 40W --- 1no.Must have Centre tapped 3A choke 4mH/ 16mH each ----2nos.Must have Commutation capacitors of 10mF/100V -------4nos.Must have AC Paper capacitor of 4mF/440V ---1no. 54 PLC Trainer (EXPERIMENT 1-Use of simulation package for different function of PLC. EXPERIMENT 2- Verify function of logic gates by using PLC. EXPERIMENT 3- Write and verify ladder program for motor ON-OFF Control with two push button)HARDWARE SPECIFICATION:TTL Input Switches : 8 Nos,TTL Momentary Switches : 8 Nos., Proximity Switch : 1 No.,Optical Transducer (two state) : 1 No., Programmable LEDs : 8 Nos., Analog input 0 to 5V DC : 8 channels, Analog output 0 to 5V DC : 1 No., 4 to 20mA Transmitter : 1No., 4 to 20mA Receiver : 1No., Current Meter : 25mA FSD 1No.,Voltmeter : 10V FSD 1 No., Piezo Electric Alarm : 1 bit.Built-in power supply.Dedicated I/O interface card suitable for IBM computer suitable for ISA slot. SOFTWARE SPECIFICATION:This is a GUI based LADDER LOGIC SOFTWAREDRAG AND DROP (D&D) an instruction instead of typing an instruction. This eliminates errors in typing. All the instructions are displayed ON-SCREEN during Design time. Each and every element is directly addressed with their NAMES not by numbers or codes, which are very difficult to remember. Ex: At design time, you call a SWITCH#0 in your Ladder program by D&D the component called SWITCH#0, and that’s it, not by typing a few digits numbers or codes.Appropriate LIST boxes (input, output) open as you D&D an instruction in LADDER WORKSPACE.Ladder workspace is 24X100 instruction CELLs are available for your use.TOOL TIP features are available at the end of each instruction prompting you “what to do next”Very user friendly.Extensive ON-LINE HELP menu available.GUI based STATUS of the entire PLC is displayed during RUN TIME.Programs are saved, retrieved, edited by simply clicking on Menu list box.Extensive EDIT features are available. 55 Power Electronics Development TrainerSize of Breadboard : 172.5 mm × 128.5mmDC Power Supply :+5 V, -5 V 500 mA,+12V, -12 V 500 mA+15 V, 250 mA+35V, -35V, 250 mAAC Power Supply :18V-0V-18V ,0V-15VOn board Firing CircuitsFrequency range : 30Hz to 900Hz variableAmplitude : 12VPWM control of G1, G2, G3 and G4Duty cycle control of “Gate”Signal is 0 to 100%SCR Assembly : 4 SCRs 2P4M, 400V/2APower Devices : IGBT-G4BC20S, MOSFETIRFZ44N,UJT-2N2646, DIACDB3,TRIAC-BT136, PUT-2N6027Circuit Components on board : Electrolytic Capacitor 10µF, 63V,Electrolytic Capacitor 1µF, 63V ,Met. Capacitor 0.33µF, 63V ,Diode 1N4007, Inductor 220uH, 4.7µH, 10mH.Pulse transformer on board :2 nos. PT4502 1:1 and one is PT4503 1:1:1Load selector : 6 load resistances- 47E/7W,1K/1W, 1K/10W, 10K/10W,120E/5W, 2K2/2W.Test points : 10 nos (Gold plated)Power Supply (Mains) : 220V/110V, 50Hz/60HzIncluded Accessories :Bread boards : 2 nos.Connecting wires : 20 nos.2mm to 1mm Patch cords : 15 nos.2mm Patch cords (Red) 16” : 4 nos.2mm Patch cords (Black)16’’ : 4 nos.2mm Patch cords (Blue) 16’’ : 12 nos.Mains cord : 1 no.with i) Power Semiconductor Application Experiment Panel ii)CON / INV Panel iii)Triggering circuit / dv/dt Protection panel 56 ELECTRICAL & ELECTRONICS MEASUREMENT LAB (6TH SEM) 57 Digital LCR meterVariable measured- L,C,R and loss angle (D factor ) Measured frequencies: 1 KHz, 100KHzDisplay: 3⅟₂ digit , Resistance: 0 to 20 MΩ, 0.1 Ω , Capacitance: 0 to 20000μF, 0.1 pF Inductance: 0 to 20000 H, 0.1μH ,D factor: 0.01 to 8.0 with 1% error 58 Distortion Factor MeterFrequency : 20 Hz to 200KHz Distortion:0.1% to 100% f.s.d. in steps ,Input sensitivity: 100mV (r.m.s.), Input impedance: 1MΩ/160pF, Voltmeter range: 300μv to 300v f.s.d. in 13 range 59 To measure L & Q by Maxwell methodFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 60 To measure the unknown capacitance by Schering bridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER & CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., DECADE INDUCTANCE WITH ROTARY SWITCH INBUILT, BACKLIGHT LED & WOODEN HARD BOX 61 To measure the unknown frequency by Wein BridgeFULL BRIDGE WITH OSCILLATOR, LED NULL BAR GRAPH & AUDIO AMPR WITH SPEAKER INBUILT FOR NULL IND., DIGITAL MULTIMETER WITH FREQ. COUNTER & CRO SIG. O/P INBUILT& CRO SIG. O/P INBUILT, IMPORTED (BOURNA) 10 TURN POT FOR NULL ADJ., BACKLIGHT LED & WOODEN HARD BOX 62 MICROCONTROLLER AND EMBEDDED LAB (5TH SEM) 63 Microcontroller Trainer Kit 1.Write a Simple Assembly Programs fora. Addition b. Subtraction b. Multiplication d. Division2. Write a Programs for (any two of the following)i. 4 x 4 Matrix Keypad Interfaceii. character based LCD Interfaceiii. Analog to Digital Conversion (On chip ADC)iv. Serial EEPROMv. Seven Segment LED Display Interfacevi. Interfacing With Temperature Sensorvii. Stepper Motor Interface8 BIT EMBEDDED MICROCONTROLLER TRAINERFEATURES•Single board design with various resources•Excellent training platform for embedded applications•Software development tools include assembler and ‘C’ compiler•Easy adaptability to different versions of microcontroller in the same family SPECIFICATIONS•Experimental board for 40 pin MCS51 and AVR family of microcontrollers•In-system programming (ISP) facility for many microcontrollers•Double RESET signal with manual key•Crystal frequency: 11.0592MHz•On-board RS232 compatible serial interface terminated in a 9 Pin D female connector•4×4 matrix keyboard•16×2 alphanumeric LCD connector (4-bit interface) and trimmer for contrast adjustment•Four 7-segment LED displays•I2C EEPROM (24Cxx)•Real time clock (DS1307) with lithium battery and SRAM•8-high current output port (500mA) for driving external loads•Two 12V sugar cube relays•Continuous tone piezo buzzer•Temperature sensor socket with thermostat functions•Four 8-bit A/D converter, one 8-bit D/A converter provided by PCF8591•All port-pins available on 10-pin box header•8 LEDs for easy logic state monitoring•8 input trigger switches using 8 push buttons•ISP programming with Flash ISP for AT89S51/52/8252/AVR•Infrared remote control receiver module IC supported•P89V51RD2BN•AT89S52 Installable software on CD•Programmers notepad : Free, open source, text editor•Flash ISP programmer software for 89SXX•Bascom basic compiler (demo version)•MIDE-51: An IDE for MCS-51 microcontroller•WinAVR : open source C compiler for AVR•Sample programs for peripherals DC 12V/500mA output power supplyEXPERIMENTS• Study of LED blink• Study of dancing light• Study of LCD display• Study of LCD-keyboard display• Study of 7 –segment display• Study of RC5 remote control test program• Study of analog to digital converter• Study of real time clock (RTC) 64 ADVANCE COMMUNICATION ENGINEERING LAB 65 To be familiar with the following network components:THIS WILL BE A FULL PACKAGE OF THE FOLLOWINGS:-** RJ5/CAT5CABLES 100 METERSRJ 45CONNECTORS 100 PCSCUTTER & CRIMPING TOOLS FOR RJ45/CAT-5CABLESCABLE TESTER/TRACKER…….. 4 PCSHUBS WITH ACCESSORIES & TOOL KIT NETWORK INTERFACE DIFFERENT CARD 66 COMPUTER NETWORK LAB 67 Network ComponentsCAT 5/5E/6 cable :100mtrs (Rs 2000/-), RJ 45 Connectors: 200pcs (Rs. 500/- )RJ 45 Crimping Tools: 05(Rs. 800/- each)LAN Cable Tester (RJ 45): 05 (Rs 1000/- each) 68 24 Port managed switchNo. of Ports: 10/100 Mbps 24 Ethernet ports, Switch Fabric: 32 Gbps, Form Factor: Rack Mountable,OS: LAN base Image, Console port: Availavble for configuration, Mac Address table: 4000 or higher, VLAN: Supported, MTU: 9100 with support for jumbo frames, Warranty: 3 years onsite comprehensive warranty including parts and labor plus onsite technical support with 24x7 69 24 Port Unmanaged switch24-port 10/100/1000Mbps Ethernet switch Wifi Router: 300 Mbps wireless router with 4 LAN ports and 1 WAN port 70 8 port HubExternal Power Supply, 8 Nos RJ-45 connectors for 10BASE-T/100BASE-TX,Ethernet Ports 8-Port, Capacity 1.6 Gbps, Wireless Speed 10 / 100 Mbps 71 Access points54 Mbps Access point for wifi network: No.of Channel: Dual channel for support upto 108 Mbps ( 2x54Mbps), Backbone connectivity: connect over Fast Ethernet through backbone switches, Security: Security enabled Wifi connectivity with option for Broadcast of SSID,Network:802.11 a/b/g/n network support, PoE: PoE enabled, Form factor: Wall or ceilling mountable with physical lock suppor. Warranty and support: 3 years on site comprehensive warranty including parts and labour plus on site technical support with 24 X 7 72 LAN TrainerEthernet (IEEE 802.3 wireless LAN (802.11),Token bus ( 802.4) Token ring ( 802.5), Data rate : 10/100 Mbps for ethernet, 1, 2, 5.5, 11 Mbps for wirless & LAN as per IEEE 802.11b, connectivity through RJ 45 connector. 73 Installation & commissioning of network(i) Laying ofOFC & CAT 6 Cable (ii) splicing (iii) Installation & network testing 74 INSTRUMENTATION AND CONTROL LAB (6th sem) 75 To measure displacement with LVDT ACTUAL LVDT WITHINSTRUMENTATION AMPLIFIERDC O/P WITH DIGITAL METER, 3and 1/2 digit LED display with polarity indicator, sensitivity of 10mV/mm in the range of 10mm. 76 To measure temperature with thermocoupleTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 77 To measure temperature with thermistorTHERMOCOUPLE SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 78 To measure pressure with strain gauge STRAIN GAUGE SENSOR WITH WAIGHT LOADING SYSYTEM SAMPLE WEIGHTS.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR 79 To plot the Characteristics of RTD (PT-100)RTD 3 WAIR SENSOR IN STEEL CASEELECTRIC WATER JAG.INSTRUMENTATION AMPLIFIER WITH DIGITAL METERCIRCUIT DIAGRAM PRINTED ON KITEXTERNAL MOUNTED ACTUAL SENSOR MERCURY THERMOMETER 80 Temperature controller with on-off controller, Temperature controller with PI controller, Temperature controller with PID controllerTemperature controller with facilities for P, I, D and relay control blocks, Operating temperature: Ambient to 90°C, Separate controls for P, I, D channel gains,Two settings for relay hysteresis, Fast 25W oven fitted with IC temperature sensor, Forced cooling option to ready oven for next experiment, Digital display of set and measured temperature on a 3½ digit built-in DVM, 0-9999 sec, timer on panel for a convenient temperature response experiment, Buffered output for recorder 81 CIRCUIT THEORY LAB 82 Determine the permeability of magnetic material by plotting its B-H curveHysteresis Loop Tracer/ BH Curve apparatus220volt AC, 50Hz supply 83 Series parallel resonance of R-L-C cktKit for Series parallel resonance of R-L-C ckt: The Set-up consist of Power supply (with variable frequency), audio oscillator with digital readout, digital RMS meters and different number of inductors (smoothly variable), capacitors, Rheostat, patch cord & manual. 84 SWITCH GEAR LAB 85 Speed control of Induction motor 1ph by using SCR3Φ, 400V ac, 50HZ.,1HP, 1440 rpm. Speed control using ac back to back configuration of SCRs and to note Speed vs. Load Characteristics at open loop condition. This unit should consist of AC 3Φ Induction Motor (1HP) coupled with a (i) DC Shunt Generator (1HP) for loading and (ii) a DC Tachogenerator to be used for speed feedback control. A DC meter must be provided for displaying the speed of the motor from the Tachogenerator with suitable AC Ammeter and Voltmeter for the measurement (AE Make Panel Type or digital) Sheet Metal enclosure with powder coating paint must be provided. (with foundation & Experiment Table) 86 C.T. & P.T. testing trainer kit C.T. & P.T.testing trainer kit - Variable AC voltage source (0-220V)& variable AC current source (0-25A), CT for 25/5A, PT for 220/110V, Autotransformer for voltage & current adjustment, MCB protection, To determine Ratio error, Phase angle error of CT & PT, with Burden box. , polarity check indicator , range selector switch. 87 Induction type electromagnetic relay* Over Current (IDMTL Electro- Mechanical Type , Model CDG-11 or equivalent) Relay,*PSM, TSM setting* Auxiliary Relay,* Counter /Timer,* D.W. Transformer, * Variac,* Knife Switch,* DC power supply for DC auxiliary relay and the relay,* Portable Ammeter.Necessary panel for the complete set up with wooden (teak wood) table (4x3x2.5) 88 Air Circuit BreakerCut section model 89 Transmission line protection simulation KitOver Current, Earth Fault, Over Voltage, Under Voltage, Directional, Differential, Distance protection 90 POWER PLANT LAB 91 Diesel generator power plantmodel of small diesel generator power plant 92 Hydro power plantmodel of micro Hydro power plant 93 Horizontal axis small wind turbinemodel 94 CSP plantmodel 95 MEASUREMENT LAB 96 Kelvin double bridgeCompletely self contained, stand alone unit with built in power supply, required meters, Standard Resistance, wooden bench, high sensitivity spot light type galvanometer, connecting patch chords and operating manuals. 97 RENEWABLE ENERGY LAB 98 Renewable Energy Labsolar PV plant- Model 99 Renewable Energy Labvertical axis small wind turbine- Model 100 ELECTRIC MACHINE LAB 101 VoltmeterVoltmeter (M.I type) 0-150V/300V/500V 102 VoltmeterVoltmeter (M.I type) 0-20V/50V 103 AmmeterAmmeter (M.I type) 0-5A/10A/20A 104 AmmeterAmmeter (M.I type) 0-1A/2A/5A 105 MultimeterAnalog Multi-meter of ISI marked: DC : 0-200 mV/ 1000 V & 0- 2mA – 10 A,AC : 0 – 200mV/1000V &0-2 mA – 20 A, Resistance : 0 – 200 Megaohm, with shock proof protection & other facilities and operatingmanuals. 106 MultimeterDigital Multi-meter of ISI marked: DC : 0-200 mV – 1000 V & 0-2mA – 10 A,AC : 0 – 1000 V & 0- 2mA– 20 A, Resistance : 0 – 200 Megaohm, with diodetesting, data hold, shock proof protection , auto power off etcfacilities and operating manuals. 107 WattmeterDynamometer Wattmeterof ISI marked : Low Power Factor ( 0.2 ) : Current Rating : 5/10 A , Voltage Rating : 150/300 / 600 V , with anti-parallax mirror , 120 mm scale length , knife edge pointer, mouldedBakelite body, portable. 108 VoltmeterVoltmeter (PMMC type) 0-150V/300V 109 AmmeterAmmeter (PMMC type) 0-2A/5A 110 StarterDC 3-point Starter : 220 V DC , 15 A 111 StarterDC 4-point Starter : 220 V DC , 15 A 112 DC Power SupplyDC Power Supply : Input : 415V, #-Phase AC, 50 Hz;Output : 220V DC , 5 KW of a standard make . 113 RheostatRheostat with sliding Jockey : 100 Ohm , 5 A 114 RheostatRheostat with sliding Jockey : 500 Ohm , 5 A 115 Digital Energy MeterDigital Energy Meter of ISI marked: Three Phase AC , 440 V , Maximum 30 A, 50 Hz with operatingmanual. 116 Digital MeggerDigital Megger for measuring insulation resistance of ISI marked: 250 / 500 V, Maximum 200 Mega ohmwith operating manual 117 VariacSingle Phase Variac of ISI marked : Input:– 230 V AC, Output : 0 – 270 V AC , 1 KVA, 50 Hzof a standard make 118 VariacThree Phase Variac of ISI marked : Input:– 415 V AC, Output : 0 – 500 V AC , 3 KVA, 50 Hzof a standard make 119 Clamp on MeterClamp on Meter of ISI marked : Digital type : For measuring Voltage ( AC/DC ), Current ( AC/DC ) , resistance, Power & Power Factor with operating manuals 120 Phase Sequence IndicatorPhase Sequence Indicator of ISI marked : 50 – 500 V AC, 25 – 60 Hz 121 Frequency MeterFrequency Meter of ISI marked: Digital Type : 240 V, 47 – 99 Hz 122 TransformerSingle-Phase Transformer : 1 KVA , 230 V/115V , 50 Hz( Air Cooled) 123 TransformerThree-Phase Transformer : 3 KVA , 415/230 V , 50 Hz 124 3-Ph Resistive LoadThree phase resistive load : 400 V , 6 KW 125 3-Ph Inductive LoadThree phase inductive load : 400 V , 3 KW 126 3-Ph Capacitive LoadThree phase capacitive load : 400 V , 3 KW 127 3-Ph StarterStar Delta automatic starter for 3 Phase,400 V, 5 Hpmotor 128 3-Ph DOL StarterDOL & Auto -Transformer Starter : 3-phase AC , 400V, 10A, 50 Hz 129 StroboscopeDigital Stroboscope - 10,000 rpm 130 DCGenerator Voltage build UPSupply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Building up Voltage in DC Generator ( Open Circuit / Saturation Characteristics: DC Shunt Motor of ISI marked : 2HP or 5HP, 220 V. Machines will have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and operating manual isalso must.(with foundation & Experiment Table) 131 Brake test in DC Series Motor Supply, Installation , Commissioning & Testing with suitable ISI markedammeter, voltmeter, starter, rheostat , digital tachometer , Spring balance & loadings, protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Brake test in DC Series Motor& load Characteristics: DC Series Motor of ISI marked : 2HP, 220 V.Machineswill have to be set on M.S.Channel base with suitable footing/ fixtures and screws etc. and operatingmanual is also must.(with foundation & Experiment Table) 132 Speed Controlof 3-Phase Squirrel cage Induction motorSupply, Installation , Commissioning & Testing with necessary & suitable ISI marked meters such as ammeter, voltmeter, frequency meter , starter, protective devices and all other accessories mounted on a standing panel board as per following specification :For Speed Controlof 3-Phase Squirrel cage Induction motorby – (i) volt /freq control method : Three phase Squirrel cage induction motor : 2HP, 400V with v/f controller.Machineswill have to be set on M.S.Channel base with suitablefooting/fixturesandscrewsetc.includingtheoperating manual.(with foundation & Experiment Table) 133 Load Test of an Alternator & % regulation at various loads with Unity Power factorSupply, Installation , Commissioning & Testing with suitable ISI marked ammeter, voltmeter, starter, star connected load , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :For Load Test of an Alternator and Determination of%-age regulation at various loads with unity power factor : DC Shunt Motor of ISI marked : 3HP, 220 V , AlternatorISI marked: 2 KVA, 415 V , 50 Hz.Machineswill have to be set on M.S.Channel base with suitable footing/fixtures and screws etc. and andoperating manual is also must.(with foundation & Experiment Table) 134 Measurement of Slip of 3-Phase induction motorSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter, stroboscope etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification :Measurement of Slip of 3-Phase induction motor by –(i) Stroboscopic& (ii ) Tachometer methods and reversing the direction of rotation of the motor : Three phase squirrel cage induction motor of ISI marked: 2 HP , 415 V , 50 Hz .Machineswill have to be set on M.S.Channel base withsuitable footing/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 135 Synchronization of two 3-Phase alternatorsSupply, Installation , Commissioning & Testing with suitable ISI marked meters such as ammeter, voltmeter, frequency meter etc , starter , digital tachometer , protective devices and all other accessories mounted on a standing Bakelite panel board as per following specification : Synchronization of 3-Phase alternator ( 2 SETS ) by– (a) Three Lamp & (b) Synchroscope Methods : DC Shunt Motors of ISI marked : 5HP, 220 V ,Alternators of ISI marked: 3 KVA, 400 V, 50 Hz.Machineswill have to be set on M.S.Channel base withsuitable footings/fixtures and screws etc. and and operating manual is also must.(with foundation & Experiment Table) 136 POWER SYSTEM LAB 137 KIT FOR STUDY OF ACTIVE & REACTIVE POWERWITH SIMULATIOL KIT & LAPTOPStudy of Active & Reactive power with simulator Kit and Laptop with appropriate software, The kit should consist of variable Inductive & Capacitive load to observe change in active & Reactive power 138 MODEL OF VARIOUS TYPES OF TURBINES USED IN POWER GENERATING STATIONSModel Piece of each type of Turbine 139 PYRANOMETERMEASUREMENT OF SOLAR RADIATION BY PYRANOMETER 140 PHOTO VOLATIC SYSTEM USED IN STREET LIGHTWITH SOLAR PLATE,PV CELL,BATTERY,CHARGER 141 STUDY OF POWER SYSTEM OF 6.6 KV/400 V SUBSTATION USED FOR A HOUSING CONPLEXMODEL 142 D.C NETWORK ANALYSERD.C NETWORK ANALYSER FOR STUDY OF DIFFERENT TYPES OF FAULTS 143 DIFFERENT TYPE OF EXCITATIONS SYSTEM USED IN ALTERNATORSTATIC EXCITER,SHAFT MOUNTED,ROTATNG TYPE EXCITER & Brushless exciter ( Model only) 144 MISCELLANEOUS 145 MOTOR-ALTERNATOR SET FOR SYNCHRONISATION OF TWO ALTERNATOR WITH SYCHRONISING PANEL INCLUDING CHECK SYNCHROSCOPE & BULB ARRANGEMENT TO PERFORM TWO BRIGHT ONE DARK LAMP METHOD1.TWO SET OF D.C MOTOR 2.5 KW,230 VOLT,3000 R.P.M WITH SPEED CONTROL ARRANGEMENT 2. TWO SET OF 1 KVA,3 PHASE,440 VOLT,3000 R.P.M ALTERNATOR WITH BASE MOUNTING & EXCITATION SYSTEM. 146 PlierPlier of good quality 147 TesterTester Screwdriver of reputed brand 148 Screwdriver setScrewdriver set of reputed brand
Contract Date: Mar 12, 2026 Contract Value : 33.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
34.
Power #9775968 AOC
Tender For Mtps-I - Es Circle - Mrt– Unit-Iv - Tg Area - Aoh Maintenance Works To Be Carried Out For The Year 2025-26 - Electrical Valve Actuators, Generator Transformer, Uat A & B And Dvr EquipmentS In Tg Area; 1 Charges for cleaning, disconnection of power cables and control cables, terminal tightness checking of actuator terminal blocks, local push button and lubricating the limit switch mechanism. 2 Charges for reconnection of power and control cables, setting of open/close limit/ torque switches, testing of modules, motors and checking of operation. 3 Charges for power/control cable jointing works for actuator. 4 Charges for Cleaning of Converter cubicles, Field Breaker cubicles, Regulation Cubicle and Field Flashing cubicles, AC/DC racks, Air conditioner units, checking the tightness ofAC / DC bus bar joints, terminal blocks in Converter panels, Field Breaker panel and Regulation Panel . 5 Charges for Opening/closing time and contact resistance measurement works of Field breaker main and FDR contacts, testing of relays, transformers & timers, carrying out the modification works for conducting the dummy load test in the Digital Excitation System and measurement of Rotor DC resistance and impedance measurement at standstill, barring gear speed and various speeds during rolling of turbine. 6 Charges for transporting the testing equipment to transformer yard, assisting for conducting OCC, SCC tests on GT, UAT’s (A& B) and its NGT, terminal tightness checking in marshaling boxes, metering and protection CT’s.
Contract Date: Aug 30, 2025 Contract Value : 2.30 Lakh
Boards / Undertakings / PSU No of Bidders 2
Contract Date: Mar 02, 2026 Contract Value : 32,072
Boards / Undertakings / PSU No of Bidders 2
36.
Defence #9749510 AOC
Tender For Construction Of Offer Md Accommodation At Island Ground Offers Enclave Chennai; 1 Lumpsum price worked out by the tenderer for BUILDINGS AND STRUCTURES as listed in Schedule ‘A’ Part-I 2 Lumpsum price worked out by the tenderer for SITE CLEARANCE/ AREA DEVELOPMENT as listed in Schedule ‘A’ Part-II 3 Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III 4 Lumpsum price worked out by the tenderer for INTERNAL ELECTRICSUPPLY & PVC CONDUIT as listed in Schedule ‘A’ Part-IV 5 Lumpsum price worked out by the tenderer forROAD/ PATH/ HARDSTANDING /CULVERTas listed in Schedule ‘A’ Part-V 6 Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI 7 Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-VII 8 Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VIII 9 Lumpsum price worked out by the tenderer forEXTERNAL ELECTRIC SUPPLY as listed inSchedule ‘A’ Part-IX 10 Lumpsum price worked out by the tenderer forLIGHTNING PROTECTIONas listed in Schedule ‘A’ Part-X 11 Lumpsum price worked out by the tenderer for FIRE FIGHTING/ FIRE ALARM AND DETECTION as listed in Schedule ‘A’ Part-XI 12 Lumpsum price worked out by the tenderer for LIFT as listed in Schedule ‘A’ Part-XII 13 SCHEDULE A PART XIII (MISCELLANEOUS ITEMS)Note: This schedule is not pre-priced by MES 14 INTERNAL WATER SUPPLY 15 S&F for 15mm dia bore 2 way bib tap/cock fancy type, cast copper alloy chromium plated, with crutch or butterfly handle one way suitable for fixing health faucet and other for bip tap, screwed for iorn pipe or ferrule complete all as specified and directed. 16 S&F for 15mm dia bore, brass CP mixer valve 2 in 1 hot and cold water including connected with shower rose, screwed for iorn pipe or ferrule, complete all as specified and directed. 17 INTERNAL ELECTRIC SUPPLY /PVC CONDUIT 18 M&L for Point wiring complete with 1.5 sq mm single core PVC insulated FRLS unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 wih ISI marked (for phase, neutral and earth) in and including stove enamelled Steel conduit with ISI Mark of minimum 20mm dia and all conduit accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed glvanised steel pressed terminal boxes alongwith suitable size modular cover plates with frames for fixing modular switches and sockets, fan regulators etc. of suiable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following :- Note: Location of light points, 6 Amp socket points and light fittings may be decided by Engr-in-charge as per site/user requirment 19 One light point controlled by one modular switch 6A one way 20 One Ceiling/Exhaust fan point controlled by one modular switch 6A 21 One 3 pin socket out let6 Amps on independent board 22 One 3 pin socket out let 6 A on same board 23 One light point controlled by two 2-way switch 24 One bell/buzzer point controlled by one bell push 25 M&L for Point wiring complete all a specified with 1100 Volts grade 4 sq mm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth)in and includingstove enamelled Steel conduit ISI Mark of minimum size 20mm dia all accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel pressed terminal boxes for fixing modular sockets of suitable sizemodules and the earth wire to be connected to common earty dolly all as specified and as directed.all as specified and as directed for One three pin modular switch socket 16 amps outlet on independent board 26 S&F modular bell switch suitable type AC 240V, 6 Amps complete all as specified and directed by Engineer-in-charge. 27 Supply and Fix Modular switches suitable for type AC 240V ,6 amps 1 Module 2 way complete all as specified and directed by Engineer-in-charge. 28 Supply and Fix call bell of multi music type AC 230 volts completeall as specified and directed by Engineer-in-charge. 29 Supply and Fix wall mounted fan of double string, steel body AC single phase, 230v of size 400mm sweep with, blades frame, louvers, oscillation control knob, tilting control white colour (body and blades) complete all as specified and directed 30 Supply and Fix decorative wall light fitiing made up of polycarbonate suitable for 9 Watts Retrofit LED LampB22 Base complete all as specified and directed 31 S&F reading light (Bed Side) wall mounting5/7 W Cool day light CCT of 3000K 400Lumen output complete all as specified and directed make PhilipsCat No 31437 or equivalent in Havells or Wipro 32 ROAD/PATH /HARDSTANDING/ CULVERT 33 M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines,edge lines ,stop lines, dashes, arrows etc. and the like n. exc 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. 34 EXTERNAL WATER SUPPLY 35 Supply ,install , test and commission of Centrifugal electrically driven self priming monoblock pump set with cast iron impeller capable of pumping 350 LPM at 36 Mtr head, squirrel cage TEFC induction motor3 phase, 415V AC,50 Hz suitable for delivery 350 LPM at 36 Mtr head coupled on common base chanel including necessary PCC foundation works, nuts and bolts, copper cable from starter to motor through PVC rigid pipe ,suitable size of suction pipe not less than 20 feet or as reqd at site, Air release valve complete all as directed and specified 36 Supply and Fix Foot Valve normax type including fixingas per IS4038 all as specified and directed 65 mm DiaMake :Kirloskar,Zoloto,L&T 37 Supply, install, test and commission LT feeder piller box/ Panel board IEC -614391 , CPRI approved,indoor type IP-43 , vermin proof, dust proof , fabricated with 2 mm CRCA sheet mounted on 40x40x4mm MS angle, 3 phase 4 wire , 440 volts , AC , 50hz with TPN aluminiumbusbar of capacity100 amps with pvc insulator heat shrink colour code sleeves , mounted on procelin insulators duly prewiredcomplete volt and amp meter , selector switch with all accessories and consists of the following switch gears :-(a) Bus bar chamber with electrolytic aluminium bus bar 100 Amp capacity for 3 phase - 01 set(b) MCCB 4 pole adjustable thermal/magnetic setting ,63A, 415 V ,25 KA- 01 Nos (c) MCCB 4 pole ,32A, 415 V ,10 KA- 02 Nos (Lift & Fire Pumps)(d) MCBTP ,32A, 415 V ,10 KA- 02 Nos (Pump Sets)(f) Supply and fixing DOL starter suitable for pumping set- 02 Nos 5 HP(g) MCB SPN 6-32 Amp 10 KA -01 Nos(Pump House)(h) Digital voltmeter, Ammeter,LED phase indicator lamp, selectror switch(i) Single phase preventer- 02 Nos (j) MCB SP 32 Amps 16 KA- 1 No, Street Light Timer digital type-01 No. 38 M&L for construction of valve chamber 450x450x450 mm depth with PCC foundation in the ration 1:4:8 brick work cement mortar in the ratio 1:6 using of class B bricks , PCC coaping at the top of the ratio 1:3:6 , plastering 15 mm thick in the ratio 1:4 including MSsheet cover 3mm thick with angle iron frame 50x50x6mm locking arrengement complete with painting on steel surface with one coat of red oxide paint over two coats of synthetic enameeled paint all as specified and directed . (Earthwork shall be measured and paid seperetely in the respective items) 39 Supply and Fix Stainer Y type made of cast iron body flanged type completely fixed to line including all necessary bolts Nuts washers Etc of size 50 mm Dia Make :Kirloskar,Zoloto,L&T 40 Supply only chlorine test kitof reputed Make for testing water chlorine with all fittments and OT solution complete 41 Supply only synthetic rubber insulatedmat 2 mm thickfor voltage upto3.3 KV as per IS 15652-2006 of Size 1 meter x 2 meter x 19 mm 42 Supply testing and installation of Bleaching Dozer Bucket Type capacity 145 Litres FRP type with all fittings and fioxtures Orifice plate Drain Valve,solution dozing line (PVC) dose cantrol Valve ,Water inlet valve, air Valve any other accessories or pipe line of size upto 25 mm are included in the quoted rates all as specified and directed and supplyCHLORINE TEST KIT 43 EXTERNAL ELECTRIC SUPPLY 44 Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x6 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead GI wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 15 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt up to 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point terminal block, commissioning & testing complete. ( Note :Main earth lead beyond 7.5 metre measured and paid for separately.) 45 M/L for LT cable route indicators Oval Shaped 200x150x6 mm cast Iron precastwith engraving LT MES CABLE embedded with PCC in mix 1:3:6 type C1 incl necessary exc, returning filling & removal of soil complete as directed. 46 .Supply and fix FRP pole box of size 168X253x115mm ,thermoplastic,polycabonate,IP-66 complete with 4 pole 32 A connector, Double compression glands-2 Nos, MCB SP 6 Amps mounted with GI clamps of suitable size with nuts and bolts on street light pole all as specified 47 Material and labour for street light bracket made of 40mm GI pipe light grade 1.5 m length bent in shape for mounting street light on one end, fixing the bracket on pole with suitable GI clamps, Nus and bolts all as specified and as directed.. 48 Fabricate, supply , install, test and commission LT feeder pilar box/panle board, outdoor type, fabricated with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter , selectro switch with all accessories and consist of the following switch gear: -( Main LTpanelatPGEPT & TA ) (i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps(ii) MCCB 4 Pole 200 Amps 36 KA-01 No ( Incoming) (iii) MCCB 4 Pole 160 Amps 25 KA-02 No(iv) LED phase indication lamp for 3 phase-01 No 49 Fabricate, supply , install, test and commission LT feeder pilar box/panle board, outdoor type, fabricate with 3.15mm CRCA sheet mounted on 50x50x6mm MS angle, 3 phase 4 wire, 440v, AC, 50 Hz, with TPN aluminium bus bar of capacity 400 Amps with pvc heat shrink colour code sleeves, mounted on porcelin insulators complete volt and amp meter , selectro switch with all accessories and consist of the following switch gear: -( Main LTpanel at Tower 1 ) (i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps(ii) MCCB 4 Pole 160 Amps 36 KA-01 No ( Incoming) (iii) MCCB 4 Pole 100 Amps 25 KA-05 No (FF,SF,TF,FF& Pump House) (iv) MCCB 4 Pole32 Amps 16 KA- 2 No ( Ground Floor & Spare)(ix) LED phase indication lamp for 3 phase-01 No 50 Supply only synthetic rubber insulatedmat 2mm thickfor voltage upto 3.3 KV asper IS 15652-2006 of Size 1 meter x 2 meter x 19 mm 51 Provision of trenchless bore using mechanical pneumatic drilling equipment for passing electric cables through HDPE pipe of 100mm dia under the existing bituminous/WBM road/PCC hard standings, depth range not less than 1.0 mtr and upto 1.5mtr and making good to the distrubed surfaces of road to match with its existing specifications all as specified and directed by engr-in-charge at site. Note : 1. Quoted rates deems to be inclusing of necessary earth work, transportation charges of Drilling machine, and cost of HDPE pipe and passing pipe through bore complete.2. Any damage to MES/Civil assets caused during trenchless bore shall be recitfied by the contractor at his own cost.Note:The rates are inclusive for obtaining necessary permission from state/Highway authorities and any other clearances as required before starting the work 52 FIRE FIGHTING SYSTEM/ FIRE ALARAM AND DETECTION 53 Supply, installation, testing, and commissioning of Fully automatic Star Delta Starter starter, suitable for the booster pump, complete with contactors, push button, LED type indicators, auto/manual selector switch, overload protection, current sensing type single phase preventer complete with all accessories and wiring etc.with ncomplete all as specified and directed 54 M & L for fire survival cable of size 3 core 16 sq mm with strandedannaealed bare copper conductor, mica tape wrapped for heat resistance up to 950deg centigrade, GI strip wire armouredand zero halaogen outersheathed XLPE insulation cable all as directed. Make: Havells/ KEI/ RR Kabel 55 M & L for PN 1.6 rated 100 mm NB polypropelene vortex inhibitor suction lift, conforming to BS 4504 with stainless wire mesh, bolts, nuts and washers, etc. complete all as specified and directed 56 M & L for PN 1.6 rated 100 mm NB CI Y -type strainer for suction conforming to IS 907: 1984 & (Reaffirmed 2020) with SS filter screen and flange drilling standard end connection conforming to IS 1538: 2018 and necessary accessories for suction side of fire pumps complete all as specified and directed.(at pump suciton header). 57 M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 32 mm X 6 mm as earth lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel, etc. complete all as specified and directed by the engineer-in-charge 58 M & L for Two wire addressable speaker with LED light flash/Beacon suitable for targeted announcements and equipped with a LED light flash ( to cater to hearing-impaired occupants). The unit shall be equipped with an LED that blinks in normal conditions and glows steadily upon activation. Both the control panel and speaker unit shall continuously scan for healthiness and cable connectivity to ensure integrity compliance. the speaker must have a minimum capacity of 5 watts with max voice current of 100mA. It shall have ABS housing along with Back box. it shall be able to produce 90 dB sound at 1 Mtr distance 59 M & L for remote repeater panel similar to main control panel capable of full supervision of all inputs an network integrity, having colour touch screen display, environmental adjustment control to maximise LCD legibility, LED status indicator. ( For power supply and OFF normal conditions) 60 M & L for low smoke zero halogen(LSOH) flame retardant fire alarm cable 2C x 1.5 Sqmm conforming to BS-7629-1, BS-6387 and BS EN 50200 and rated for 500V drawn through and including concealed PVC conduit and accessories of min 20mm dia NB and having plain annealed stranded copper conductor with primary insulation of glass mica fire resistant tape and secondary insulation of high performance silicon rubber, earth/drain wire of annealed tinned copper, electrostatic screen of aluminium fire barrier and type LTS3 outer sheathed conforming to BS 7655, suitable for operating temp -30 deg centigrade to +70 deg centigrade and min bending radius being six time the overall cable diameter, red in colour, including laying termination and ferruling complete all as specified and as directed 61 M&L for Firemans switch and Interconnecting with LV Switch The cost of any balance item to make MOEFA system installed under Sch A part XI above is deemed to be included in the quoted rates so as to make the system complete and fully functional ass per the prevailing engineering. 62 Supply and fixingof Mechanical foam type fire extinguishers, 9 Ltr capacity, IS:15683 : 2006, complete. 63 Supply and fixingof Dry powder ABCstoredpressuresqueezegriptypefire extinguishers, 9 kg capacity, IS:15683 : 2006, filled with ABC Mono AmmoniumPhosphatebasepowder-90completewithdischarge hose and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure Guage, which work effectively on allclass of fires (A, B, C & Electrical fires)complete. 64 Supply & fixing of 4 Nos of 9 lts capacityround bottom sand /water buckets along with round bottom type , enamel painted white inside and red outside& letter fire in black outside & handle with mounting bracket along with suitable MS stand to install the buckets as per the local fire standards 65 LIFT 66 Earthing with galvanised steel earth plate electrode 60 cm x 60 cm x3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metre below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level connected to main earth lead Copper strip 20 mmx3mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 of MES Schedule Part I 1991, GI earth lead protected by GI pipe 40 mm dia light grade, providing and connected to earth test point with & including necessary excavation & earth works in any type of soil, returning filling, disposal of surplus soil to 50 metre, filing with mixture of charcoal and common salt upto 15 cm above top edge of earth plate, pit of PCC 1:2:4 with precast cover of RCC 1:2:4, watering arrangement with GI funnel, 20 mm dia GI light grade watering pipe, earth test point terminal block, commissioning & testing complete. Note :Main earth lead beyond 7.5 metre measured and paid for separately.) 67 ELECTRIC CHIMNEY 68 Supply Install Testing and comissioning of Electric Chimney of size, Filterless Wall Mounted type,Operating Voltage 220 Volts 50 Hz with ,Auto Clean 3 speed cantrol gesture with 2X 1,5 LED and all other necessary fittingsand fixtures required complete all as specified and directed.Supply, erection & testing of electricalchimney with the following specificationsSize: 90 cmShape / mounting: Box / wall mountingSuction capacity : 1500-1800 cum/hrAir outlet size: 150 mmDuct size : 150 mm Duct :MOC- Stainless Steel,Duct pipe/baffle filter: inclusive as required.Motor type: BLDC motor, 240W.Blower type: MetallicLamp: 2 x 1.5 WFinish: Stainless SteelFeatures: Low Noise (less than 62 dB) steam auto cleanControls: Dual touch, multi speed option, motion sensor”.Make: Faber/ Hindware/Glen /Kaff/Cropmton 69 DG SET 70 Supply, installation, testing and commissioning of 40 KVA / 32 KW,(The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of40 KVA or equivalent, developing 1500 RPM, Water Cooled, electric start coupled toEquivalentalternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters,with emission control device as per CPCB IV + Norms and updated till date on procurement and CPCB approved acoustic enclosure suitable for ambient condition atChennai with integral fuel tank with battery and leads and accessories complete including required PCC foundation as per manufacturers instruction and confirming to conditions as per IS provisions:- 71 (A) Alternator :- Standard design alternator rated at 40 KVA net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class H and voltage regulation of ± 1 % at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS/IS – 4722 and as per the following provisions:- Make:- KIRLOSKAR/JYOTI / STAMFORD/CATERPILLAR(a) Insulation class - H(b) Temperature rise Class - H(c) Excitation: Self Excited(d) Regulation performance: The voltage is kept constant with ± 1 %, manual voltage adjustment within ± 5%(e) Frequency regulation ± 1 %(f) 2 runs of UG cable of suitable size from Alternator to AMP is deemed to be include in quoted rate. 72 (B) Diesel Engine: - Adequate capacity Diesel engine suitable for 40 KVA coupled drive independently above alternator and after considering derating as per site conditions after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all asspecified and required for safe handling and operation salient features of accessories shall be as under Make :- KIRLOSKAR/CUMMINS / CATERPILLAR (GEMCO) 73 (a) Fly wheel with housing (b) Cooling system :- Mounted radiator with fan & belts.(c) Cooling pump: - Centrifugal type belt driven. (d) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade up to and away two meters height from top of enclosure including necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminum sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type Exhaust manifold Silencer: Residential type Belows 74 (C) Fuel System :- Fuel injection system with fuel injectors, fuel injectionsolenoid switch/nozzles/ governor mechanical type capable for 1 % speed/frequency regulation.(i) Fuel filters(ii) Fuel hoses(iii) Lub oil System :-(iv)Lubricating oil filter(v) Lubricating oil pump(vi) Air Intake System :-(a) Air intake Manifold(b) Air cleaner dry type(a) Starting System :- Electric Self starter with maintenance free batteries including battery charging alternator.(b) Batteries:- 1 No. Maintenance free Battery of suitable AH capacity complete with copper conductor multistranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified.Make:- EXIDE / AMRON / Produced by original DG set manufacturers 75 (i) Starter gear ring(ii) Start and stop push button(iii) Ignition key / Switch(iv) Handling and operation: Salient features of accessories shall be asunder:(a) Radiator with blower fan(b) Corrosion inhibitor coolant(c) Paper element filters for fuel, lub oil and by pass.(d) Governor controlled direct fuel injection system(e) Fly wheel housing and fly wheel. 76 (D) Generator Monitoring Panel: Comprising of following:-(a) Microprocessor based integrator generator set monitories, metering,protection and control system with built torque matched volts/H3 over load control.(b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown)(c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down)(d) Relay drivers for remote annunciations(e) Cyclic cranking(f) Auto/manual start stop(g) Alternator trim adjustment from the front key pad(h) Operates within a temperature range 0- 50°C and humidity up to 95%(J) Remote monitoring capability through separate interface modulesk) Genset metering parameters like lube oil pressure, coolant temperature, engine speed(rpm), run hours, DC voltage, 3 phase volts and 3 phase amperes, frequency, KW, KVA, power factor 77 (l) Safety Controls : - Engine low lube oil pressure, high water temperature and over speeding of engine.(m) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling fly wheel housing.(n) Accessories :-A VM Pads built or separately mounted to manufacturer base frames.(o) Base Frame: - Made out of ISMC 200 of sturdy design made of MS channel with necessary reinforcement and predetermined holes. (p) Fuel Tank :- Daily service fuel tank of capacity minimum 08 hrs running storage (Inbuilt) made out of 3mm thick (Heat Retardant) sheet top and bottom with calibrated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity and connected pipe line should be installed with in built inside the acoustic enclosure is inclusive of the cost of DG Set and is as per manufacturer design.(q) Deliverables:- Confirms the norms established by CPCB. 78 (E) AMF PANEL:-(a) Auto Main Failure (AMF) panel made out of 2 mm thick CRCA sheet, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase,4 Wire, AC 50 Hz having aluminum bus bar capacity required to carry current at 100% load of 40 KVA DG set with three phase and half neutral color coded, prewired with copper flexible cable, be all as specified with the following accessories, control cable from Gen set to AMF panel: (i) 63 Amps, 4 pole contactor - 2 Nos.(ii) MCCB, 4 Pole 63 Amps, 25 KA-2 Nos for both supplies suitable fuse links.(iv) CTs 50/5A for both the supplies.(v) DC Ammeter.(vi) DC Voltmeter.(vii) Push buttons.(viii) Indication Lamps.(ix) 2 over load+ earth leakage relay. 79 (x) Multi functional digital meter for KWH,KVA,KW,Amps,volts, frequency,power factor etc.(xi) SMPS Battery charger 12V, with trickle & Boost charging(xii) On/ Off switch.(xiii) Automatic/manual switch.(xiv) Hooter.(xv) Voltage sensing relay.(xvi) Six window enunciator for fault indications.(xvii) Electro magnetic relays.(xviii) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains :- A, V, Hz. 80 (F) Acoustic enclosure: CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:-(a) Custom built product for various equipments, with ensure the optimum performance without duration. 81 (b) Rugged in construction maintenance free and modular designs which facilitate easy at site.(c) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets.(d) Sheet metal components of the enclosure should undergo various stages of surface treatment prior to painting which leads to be better life of the enclosure against eathering action.(e) Special paint treatment with pure polyester 82 powder/epoxy to be provided for better weather resistance.(f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently.(g) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.(h) Working space is to be provided around tube equipment for easy maintenance / repairs.(j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per the requirement.(k) A see through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation.(l) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided.(m) Deliverables. 75 dBA @ 1 mtr at 75% load under free field conditions. The temp inside tee enclosure will be within as per manufacturers recommendations above ambient temp. 83 (n)The enclosure should be provided with bulk head light fitting for inside illumination(o) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform.(p) The DG Set should be provided with external Emergency stop push button.(q) The acoustic enclosure parts shall be of powder coated after pre treatment process.(r) The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade. 84 Make for AMF PANEL: DG SET OEMMake for ACCOUSTIC PANEL: DG SET OEMThe following provisions are deemed to be included in the rate quoted forDG set:-(a) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil and final successful acceptance test.(b) DHPP for testing purpose shall be supplied by the contractor without any extra cost to department.(c) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. 85 (c) The quoted rate shall be deemed to be inclusive of 12 hours test run at site including of one hour on 10% overload in presence of representative detailed by accepting Officer, all arrangements are to be made by thecontractor for tests.(d) Rate quoted shall be deemed to be included in making necessary holes to walls and making good the disturbed surfaces to match to original specification and connecting up all as specified and directed . 86 (G) Civil Works :- All civil works with PCC plat form and related tofoundations including of panel and equipments and making good theexisting structure of disturbed during installation and commissioning ofGenset. The depth of the foundation shall be minimum 300 mm with ant vibration pads or as recommended by the manufacturer. 87 M & L earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanised iron earth strip 32 x 6mm dia, by means of nuts, bolts,check nuts and washer etc. of galvanised iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test pointincl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4)and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. 88 Note :- The cost of 7.5m long galvanised iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI light grade is deemed to be included in quoted unit rate. 89 PILE FOUNDATION,PILE CAP AND GRADE BEAM 90 450mm diaBoring for Bored cast in situ piles 16 metres in soil and getting out and disposal ofspoil to a distance out side MD Land using DMC method (Direct mud circulation) through rig mechine complete all as specified and directed. 91 500mm diaBoring for Bored cast in situ piles 16 metres in soil and getting out and disposal ofspoil to a distance out side MD Land using DMC method (Direct mud circulation) through rig mechine complete all as specified and directed. 92 Add/Deduct to above item No -58 450mm bore caste in situ piles for each metrecomplete all as specified and directed. 93 Add/Deduct to above item No -59500mm bore caste in situ piles for each metre complete all as specified and directed. 94 450mm diaBoring for Bored cast in situ pilesin Chiselling / cutting through for boring for cast in situ piles through rig mechine in soft rock and getting out and disposal of spoil to a distance out side MD Landcomplete all as specified and directed. 95 500mm diaBoring for Bored cast in situ pilesin Chiselling / cutting through for boring for cast in situ piles through rig mechine in soft rock and getting out and disposal of spoil to a distance out side MD Landcomplete all as specified and directed. 96 450mm diaBoring for Bored cast in situ pilesin Chiselling / diamond cutting through for boring for cast in situ piles through rig mechine in hard rock and getting out and disposal of spoil to a distance out side MD Land complete all as specified and directed. 97 500mm diaBoring for Bored cast in situ pilesin Chiselling / diamond cutting through for boring for cast in situ piles through rig mechine in hard rock and getting out and disposal of spoil to a distance out side MD Land complete all as specified and directed. 98 S&F TMT 10 mm and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with MS wire (annealed)not less than 0.9 mm dia conformig to Fe 500D CRS. and guide ring will be welded with main barscomplete all as specified and directed. 99 All as per item no above herein before but 6 mm dia and over upto including 10 mm dia in stirrups, spacersand binders. 100 M & L for design Mix RMC M-30 RCC inpile foundations as per derived depth complete all as specified and directed. 101 Complete Chiseling M-30 design mix concrete pile of dia 450mm of depth as required at site and removal complete all as specified and directed. 102 Chiseling M-30 design mix concrete pile of dia 500mm of depth as required at site and removal complete all as specified and directed. 103 The following Carrying out Initial Load Test on 450/500/600 mm dia. bored cast-in-situ piles as per IS-2911 (Part-IV) complete all as specified and as directed. 104 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 450mm dia pile. complete all as specified and directed 105 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 106 Lateral load test,as per IS-2911 (Part-IV) for 450mm dia pile .complete all as specified and directed 107 Lateral load test,as per IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 108 Carrying out Routine Load Test on 450/500/600mm dia. bored cast-in-situ piles as per IS-2911 (Part-IV) complete all as specified and as directed. 109 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 450mm dia pile.complete all as specified and directed 110 Vertical load test (compression), as per IS IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 111 Lateral load test,as per IS-2911 (Part-IV) for 450mm dia pile.complete all as specified and directed 112 Lateral load test,as per IS-2911 (Part-IV) for 500mm dia pile.complete all as specified and directed 113 Integrate Test for all Routine piles .complete all as specified and directed 114 Excavating over areas in soft /loose soil, n exc 1.5 m deep and getting out complete all as specified and directed. 115 Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m indepth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. 116 M&L for Plain Cement concrete Type B2 1:2:4 (40mm graded aggregate) as in foundations, filling and mass concrete complete all as specified and directed. 117 M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. 118 M & L for design Mix RMC M-30 RCCas inpile cap complete all as specified and directed. 119 S & F MS liner for piles of any size using MS sheet of any thickness all as directed by Engineer in charge. 120 M&L for Formwork to sides of concrete foundations, footings, Pile cap, grade beams bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter
Contract Date: Mar 06, 2026 Contract Value : 10.17 Crore
Statutory Bodies & Commissions/Committees No of Bidders 5
Contract Date: Ref. Documents Contract Value : 6.33 Lakh
Boards / Undertakings / PSU No of Bidders 3
Madhya Pradesh View Result →
39.
Power #9633245 Technical Bid
Tender For Supply Of 3 Phase, 415 Volt, Induction Motors And Dc Motors For Stage-I To Iv Of Lt Electrical At Stps, Suratgarh . , Supply Items:- , 3 Phase Ac Induction Motor 120Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd-315M , 2975 Rpm ,Ip55, 189 Amp, Connection Delta, Mounting Foot , Duty S1 Bearing Nde 6315 C3 / De 6315 C3 Ins. Class-F Ic-411 With Space Heater, Amb. Temp. 55 Deg Cable Size:Al 2X3cx185 Sqmm Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Seal Air Fan , 3 Phase Ac Induction Motor 45Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd-250M , 2955 Rpm ,Ip55, 72 Amp, Connection Delta, Mounting Flange Vertical, Duty S1 Bearing Nde 6314 C3 / De 6314 C3 Ins. Class-F Ic-411 With Space Heater, Amb. Temp. 55 Deg Cable Size:Al 3Cx185 Sqmm Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Jop , 3 Phase Ac Induction Motor 100Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd-315S , 2975 Rpm ,Ip55, 157 Amp, Connection Delta, Mounting Flange Vertical, Duty S1 Bearing Nde Nu315 C3 / De 6315 C3 Ins. Class-F Ic-411 With Space Heater, Amb. Temp. 55 Deg Cable Size:Al 3Cx185 Sqmm Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Aop , 3 Phase Ac Induction Motor 7.5Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size 160L , 1445 Rpm ,Ip55, 14.5 Amp, Connection Delta, Mounting Flange Vertical, Duty S1 Bearing Nde 6209 Zz / De 6309 Zz Ins. Class-F , Amb. Temp. 55 Deg Cable Size:Cu 3Cx10 Sqmm Starting Mehod= Vfd Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Rc Feeder Unit-6 , 3 Phase Ac Induction Motor 55Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Efficiency-94% Frame Size Hx+250Mc4 , 1475 Rpm ,Ip55, 99 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6313 C3 / De 6315 C3 Ins. Class-F Ic-411 With Space Heater, Amb. Temp. 55 Deg Cable Size:Al 3Cx185 Sqmm Terminal Box =Top From De Conforming To Is-12615/Iec60034 , Is 325, For Ct Fan U#3 & 4 , 3 Phase Ac Induction Motor 37Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3,Frame Size Sc225 (Equivalent To Ld225 Smk Ii), 1475 Rpm ,Ip55, 63Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6313 C3 / De 6313 C3 Ins. Class-F Ic-411 With Space Heater, Amb. Temp. 55 Deg Cable Size:Al 3Cx95 Sqmm Terminal Box =Lhs From De Conforming To Is-12615/Iec60034 , Is 325, For Ct Fan U#1,2 & 5 , 3 Phase Ac Induction Motor 45Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Sc225 (Equivalent To Ld225 Smk Ii), 1475 Rpm ,Ip55, 78 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6313 C3 / De 6313 C3 Ins. Class-F Ic-411 With Space Heater, Amb. Temp. 55 Deg Cable Size:Al 3Cx95 Sqmm Terminal Box =Lhs From De Conforming To Is-12615/Iec60034 , Is 325, For Ct Fan U# 6 , Dc Scanner Fan Motor Kw-3.7 Frame- Fn12078, Speed -2880 Rpm, Armature Voltage- 220V, Armature Current- 21 A, Field Current- 0.24 Amp., Type- St. Shunt, Installation Class-F, For Unit #4 , 3 Phase Ac Induction Motor 3.7Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Pm112 , 2850 Rpm ,Ip55, 7.0 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6206Zz / De 6306 Zz Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Ac Scanner Fan Unit 1, 2, 3, 4 & 5 , 3 Phase Ac Induction Motor 0.55Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd90shd,925 Rpm ,Ip55, 1.0 Amp, Connection Delta, Mounting Foot+ Flange, Duty S1 Bearing Nde 6205 Zz / De 6205 Zz Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Lhs From De Conforming To Is-12615/Iec60034 , Is 325, For Aph Guide Bearing Lop , 3 Phase Ac Induction Motor 0.75Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd90shd,1405 Rpm ,Ip55, 1.9 Amp, Connection Delta, Mounting Foot+ Flange, Duty S1 Bearing Nde 6205 Zz / De 6205 Zz Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Aph Support Bearing Lop , 3 Phase Ac Induction Motor 11Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd160l , 1460 Rpm ,Ip55, 20 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing De/Nde 6309-2Rs Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Lhs From De Conforming To Is-12615/Iec60034 , Is 325, For Aph , 3 Phase Ac Induction Motor 0.25Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size D80d , 930 Rpm ,Ip55, 1.0 Amp, Connection Delta, Mounting Flange, Duty S1 Bearing De/Nde 6204Zz Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Lhs From De Conforming To Is-12615/Iec60034 , Is 325, For Coc , 3 Phase Ac Induction Motor 3.7 Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Pm100l , 2850Rpm ,Ip55, 4.55 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6206 Zz / 6208 Zz Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Id Fan Blower Unit 1To 5 , 3 Phase Ac Induction Motor 2.2Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size 90L , 2850Rpm ,Ip55, 4.55 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6205 Zzc3 / 6205 Zzc3 Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Id Fan Lop Unit 1To 5 , 3 Phase Ac Induction Motor 37Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd225s , 1480Rpm ,Ip55,63 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing De/Nde 63132Rs Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Lhs From De Conforming To Is-12615/Iec60034 , Is 325, For Mill Aux Motor , 3 Phase Ac Induction Motor 1.1Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size D80 , 2840Rpm ,Ip55, 2.35 Amp, Connection Delta, Mounting Foot, Duty S1 3 Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Id Fan Lop Unit 6 , Coumpound Dc Motor 8.5Kw (11.4Hp) Frame No.:- Afs225l Kw :- 8.5 (11.4 Hp) Type :- Compound Extn :- Self Insulation Class :- F Enclosure :- Ip 55 Bearing Ce :- Nu311 Nce :- 6311 Armature Volts :- 150 Armature Ampr. :- 67 Excitation Volts :- Self (150) Excitation Ampr. :- 1.5 Cooling :- Ic 0141 Rpm :-1450 Duty :- S1 Amb. :- 50 Oc Alt :- 1000 Mtrs Mtg :- B3 Gd2 :- 1.5 Kgm2 Ref. No. Bgad 0103 M/C No. Dask4045, Wt :- 450 Kg. Spcn :- Is4722 For Dc Sop Of Generators Seal Oil System Unit#1 To 6 , 3-Phase Induction Motor 7.5Kw (10Hp) Volts. :- 415+/- 10 % Ampr. :- 14.5 Rpm :- 1440 Connection:- Delta Bearing No. 6308/6208Zz Lub. Lith Frame :- Nd 132 M Ip :- 55 3 Ph :- 50 Hz Duty :- S1 Rating :- Construction Class :- F Insulation Motor No. :- In1942qj/Yb0119 , Mounting Foot Conforming To Is-12615/Iec60034 Is 325 , For Ac Sop Of Seal Oil System Of Generators Unit#1 To 6 , 3-Phase Induction Motor 0.75Kw/1Hp Volts: - 415 ? ±10 % Design: - Flame Proof Enclosure Type: - 1Mj3903-2 , Insulation Class: - F Connection:- Star Strengthening C :- 5.0 Amps Strengthening T: - 220% Flt Rpm: - 2825 Amps: - 1.81 Duty: - S1 Frequency: - 50 Hz Ip: - 55 Fr Size: - 90 L Epf. :- 72% Group: - Iia, Iib Bearings: - De/Nde- 6205Zz C3 , Mounting Foot Conforming To Is-12615/Iec60034 Is 325 , For Bceb Of Unit#1 To 6 , 3-Phase Induction Motor 1.1Kw Voltage- 415+/-10% Freq.- 50Hz, Current- 3.2Ampr. , Connection-Star Speed- 2850Rpm, Ip- 55, Duty-S1, Class-F, Mounting Foot, Conforming To Is-12615/Iec60034 Is 325 , For H2 Gas Dryer Blower , 3 Phase Ac Induction Motor 55Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Efficiency-94% Frame Size Hx+250Mc4 , 1475 Rpm ,Ip55, 99 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6313 C3 / De 6315 C3 Ins. Class-F Ic-411 With Space Heater, Amb. Temp. 55 Deg Cable Size:Al 3Cx185 Sqmm Terminal Box =Top From De Conforming To Is-12615/Iec60034 , Is 325, , 3 Phase Ac Induction Motor 15Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Nd160l , 1460 Rpm ,Ip55, 20 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing De/Nde 6309-2Rs Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Lhs From De Conforming To Is-12615/Iec60034 , Is 325. , 3 Phase Ac Induction Motor 3.7 Kw 415 Volt+- 10% ,50Hz,Eff Class=Ie3, Frame Size Pm100l , 970 Rpm ,Ip55, 4.55 Amp, Connection Delta, Mounting Foot, Duty S1 Bearing Nde 6206 Zz / 6208 Zz Ins. Class-F , Amb. Temp. 55 Deg Terminal Box =Rhs From De Conforming To Is-12615/Iec60034 , Is 325, For Air Ventilaton Fan Installed Above Turbine Floor/Cw/Acw/Fo Pump House
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 1
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : 10.62 Lakh
Boards / Undertakings / PSU No of Bidders 1
West Bengal View Result →
43.
Educational and Research Institute #9534195 AOC
Tender For List Of Instrument Require Of Physics , Instruments And Skulls (Non-Recurring) & Tentative Total For Non-Recurring Practical Requirements , Signal Generators: 20 Mhz , Analog Cro 20 Mhz , Metravi Rps-3005 Dc Regulated Power Supply - Single Output With Backlit Lcd Of Variable 0-30V / 0-5A Dc: 10 Pcs , Metravi Digital Storage Oscilloscope 100 Mhz White & Blue, Dso-5100E: 01Pc , To Determine G And Velocity For A Freely Falling Body Using Digital Timing Technique. Complete With : Free Fall Stand, Microcontroller Base Digital Time Measurement System, Ball & Pendulum Bob, Electromagnet Power Supply. , Determination Of The Frequency Of Ac Mains With A Sonometer Using A Magnetic Wire Complete Experimental Set With: 1. Sonometer: Size Of The Resonance Box Is 48 X 8 X 4 - Top Finished With Teak Ply- Sliding Jockey Fitted With Transparent Perspex Index Plate - Complete With Two Wedges, Brass And Steel Wire - Without Weight. Supplied Without Weights. 2. 2/4/6/8/10/12V - 1A Power Supply 3. Bar Magnet 4. Slotted Weights With Hanger 200Gmx5 5. Metre Scale. Wooden 6. Screw Gauge With ½ Mm Screw Pitch 7. Plug Key. 1 Way 8. Rheostat 50Ohms/100Ohms -1A , Determination Of The Velocity Of Ultrasonic Waves In A Given Liquid Objective: 1. To Study The Diffraction Of Light Due To Propagation Of Ultrasonic Wave In A Liquid 2. To Determine The Speed Of Sound In Various Liquids At Room Temperature 3. To Determine The Compressibility Of The Given Liquids. Apparatus: 1. Radio Frequency Oscillator Fitted With A Frequency Meter 2. Quartz Crystal Slab Fitted With Two Leads. 3. Long Neck Spectrometer 4. Glass Cell With Sample Liquid (Kerosene/Toluene/Turpentine Oil Etc) 5. Sodium Lamp. Philips. 35W 6. Lamp House 7. Transformer For N Lamp. , To Determine The Wavelength Of Sodium Light Using Newtons Rings Complete With Two Motion Newtons Ring Microscope, Set Of Newtons Ring Lens With Mounting & Adjustment Arrangement. One Plano-Convex Lens And One Optically True Parallel Glass Plate Are Put Together Inside A Brass Cup With Screw Cap Arrangement And Is Fitted With Leveling Screws -One Glass Plate With Arrangement To Incline Is Fitted On The Same Cup- Supplied With One Lens Fitted In Metal Frame And Base With Leveling Screws For Parallel Rays Form The Source. Lamphouse Buit In With Na Lamp. Transformer External. , Calibration Of A Polarimeter And Determination Of The Concentration Of An Active Solution Polarimeter. Arc-Biannual Rate Contract Quartz. It Has Laurent Quartz Device Which Makes The Instrument Sufficiently Accurate & At The Same Time Simple & Suitable For Use With Sodium Light. The Circular Head Is Attached Near To The Analyser & Vernier Movable Over This Scale Enable Reading Of Optical Rotation Accurate To 1/10Th Deg. A. 200 Mm Tube For Containing The Solution Under Study For Its Optical Activity Is Supplied With The Instrument. The Whole Optical System Is Mounted On A Sturdy Adjustable Tripod Stand. .Model: Dt-Pol-Bqz Optional: Na Lamp. Phillips 35W Lamp House Transformer For Na Lamp Lamp House , To Determine The Coefficient Of Thermal Conductivity Of Copper Using Searles Apparatus Ec Grade 99.80% Pure Cu Used For Accurate Result. Copper Rod About 30 Cm Long & 2.5 Cms. Dia. Two Ends Are Fitted With Steam & Water Jacket Respectively. Thermometer Chambers Are At Inlet & Outlet Of Water Flow - Two Holes For Thermometers At Copper Rod - Fitted Inside A Wooden Box Packed With Felt. , Determination Of The Value Of The Stefans Constant Measurement Of Stefans Constant Using Black Body Radiation. Complete With Stefans Conatant Apparatus, Very High Sensitive Light Spot Galvanometer With Sensitivity Control, High Quality Thermocouple.3 Lt Cu Boiler, Rubber Tube, Electrical Heater With Temp. Control.Model: Dt-Sbbr , To Calibrate A Thermocouple For Measuring The Temperature In A Specified Range Using I) Null Method, Ii) Direct Measurement Using Op Annual Periodical Maintenance Difference Amplifiers Thermocouple Emf Measurement Kit Comprising Of : Dc Power Supply:+12V&-12Vfixed Op Annual Periodical Maintenance With On Board Circuit Arrangement Digital Voltmeter To Read Output Voltage On Board Bread Board Suitable Jacks & Detailed Manual Thermocouple. Cu Constantan. Teflon Coated. Thermometer 110Deg Stand For Holding Thermometer Water Bath For Boiling Water - With Heating Arrangement Ice Bath 250 Ml Plastic Beaker Model: Ct-Opamp , To Determine The Temperature Coefficient Of Resistance Using The Carry Foster Bridge , To Setup The Millikan Oil Drop Apparatus And Determine The Charge Of An Electron. , To Analyze Elliptically Polarized Light By Using Babinets Compensator. , To Determine The Refractive Index Of (1) Glass And (2) A Liquid By Total Internal Reflection Using A Gaussian Eyepiece. , Verification Of Brewsters Law And Finding Of The Brewsters Angle. Verify Brewsters Law & Fresnels Equation For Reflection Of E.M. Waves With The Help Of Spectrometer, Prism, Two Polaroids And Sodium Light. Complete With : High Grade Spectrometer. 7 Circle. 20 Sec Vernier With Circular Slit & Micrometer Scale. Stainless Steel Scale. The Achromatic Objectives Used In The Telescope & The Colorimeter Are Of Very Superior Quality. The Scales And Verniers Are Automatic Machine Divided. Cover Plate Is Provided To Protect The Scale And Vernier From Dust And Carries Two Transparent Windows For Verniers. Complete With Prism Clamping Device & Diffraction Grating Stand. Provided With Vertical Adjusting Screws To Both The Colorimeter & Telescope. Clamping Devices Are Provided To Lock The Colorimeter & Telescope After Adjustment Edf Prism (Prince) Polarizer & Analyzer. Sodium Lamp. 35W Philips Lamp House. Powder Coated. Heavy Type, Transformer For Na Lamp , Single Output And Backlit Lcd Display Of Variable 0 - 30V / 0 - 5A Dc , To Study The Motion Of Spring And Calculate (A) Spring Constant, (B) G And (C) Modulus Of Rigidity. , To Determine The Moment Of Inertia Of A Flywheel/Regular Shaped Body. , To Determine G And Velocity For A Freely Falling Body Using Digital Timing Technique. , To Determine The Youngs Modulus Of A Wire By Optical Lever Method. , To Determine The Modulus Of Rigidity Of A Wire By Maxwells Needle/Dynamical Method. , To Determine The Elastic Constants Of A Wire By Searles Method. , To Determine The Value Of G Using Bar Pendulum/Katers Pendulum. , To Determine The Value Of Youngs Modulus By Flexure Method. , To Verify The Thevenins, Nortons And Maximum Power Transfer Theorems , To Study The Response Curve Of A Series Lcr Circuit And Determine Its (A) Resonant Frequency, (B) Impedance At Resonance, (C) Quality Factor And (D) Band Width , To Study The Response Curve Of A Parallel Lcr Circuit And Determine Its (A) Anti- Resonant Frequency And (B) Quality Factor , Measurement Of Charge Sensitivity And Cdr Of A Ballistic Galvanometer , Determination Of A Ballistic Galvanometer Constant By Capacitor Charging-Discharging Method , Construction Of A One Ohm Coil , Determination Of A Ballistic Galvanometer Constant By The Solenoid Method , Determination Of Mutual Inductance Of Two Coils By Carey-Fosters Method , To Draw N-L Curve With The Help Of A Sonometer And Hence Find The Frequency Of An Unknown Fork , Determination Of The Frequency Of Ac Mains With A Sonometer Using A Magnetic Wire , Determination Of The Velocity Of Ultrasonic Waves In A Given Liquid , Determine The Refractive Index Of The Material Of A Prism Using Sodium Source , To Determine The Dispersive Power And Cauchy Constants Of The Material Of A Prism , To Determine The Wavelength Of Sodium Light Using Fresnel Biprism , To Determine The Wavelength Of Sodium Light Using Newtons Rings , Determination Of The Width Of A Single Slit Producing A Fraunhofer Diffraction Pattern , To Determine Wavelength Of (1) Na Source And (2) Spectral Lines Of Hg Source Using A Plane Diffraction Grating , Calibration Of A Polarimeter And Determination Of The Concentration Of An Active Solution , To Determine The Resolving Power Of A Plane Diffraction Grating , To Determine The Coefficient Of Thermal Conductivity Of Copper Using Searles Apparatus , To Determine The Coefficient Of Thermal Conductivity Of A Bad Conductor By Lee And Charltons Disc Method , Determination Of The Value Of The Stefans Constant , To Study The Variation Of Thermo-Emf Across Two Junctions Of A Thermocouple With Temperature , To Determine The Temperature Coefficient Of Resistance And The Boiling Point Of A Given Liquid Using Platinum Resistance Thermometer , To Calibrate A Thermocouple For Measuring The Temperature In A Specified Range Using I) Null Method, Ii) Direct Measurement Using Op Annual Periodical Maintenance Difference Amplifiers , To Determine The Coefficient Of Thermal Expansion Of A Metallic Rod Using An Optical Lever , To Determine The Temperature Coefficient Of Resistance Using The Carry Foster Bridge , To Determine The Coefficient Of Thermal Expansion Of A Metallic Rod Using Travelling Microscope , To Determine The Pressure Coefficient Of Air By Constant Volume Method , To Determine The Electronic Charge (E) And The Work Function (F) Of A Cathode Material From The Plot Of The Stopping Potential (V0) Versus Frequency Using A Photocell With A Light Source Of Adjustable Frequencies (Use At Least Four Leds Of Different Colors). To Determine The Plancks Constant From The Plot Of The Stopping Potential (V0) Versus Frequency () Using A Photocell With A Light Source Of Adjustable Frequencies (Use At Least Four Leds Of Different Colors). To Calculate The Wave Number And The Wavelength Of The H-Alpha Line In The Balmer Series Of The Hydrogen Emission Spectrum. To Determine The Excitation Potentials Of Mercury Byfranck-Hertz Experiment. To Determine The Value Of E/M By (A) Magnetic Focusing Method Or (B) Using A Bar Magnet. To Setup The Millikan Oil Drop Apparatus And Determine The Charge Of An Electron. To Study V-I Characteristics Of Pn Junction Diode, And Light Emitting Diode. To Study The V-I Characteristics Of A Zener Diode And Its Use As Voltage Regulator. Study Of V-I & Power Curves Of Solar Cells, And Find Maximum Power Point & Efficiency. To Study The Characteristics Of A Bipolar Junction Transistor In Ce Configuration. To Study The Frequency Response Of Voltage Gain Of A Rc-Coupled Transistor Amplifier. To Study A Wien Bridge Oscillator For A Given Frequency Using An Op-Amp. To Design An Inverting / Non-Inverting Amplifier Using Op-Amp (741) For Dc Voltage Of Given Gain. To Add Two Dc Voltages Using Op-Amp In Inverting And Non-Inverting Mode. To Investigate The Use Of An Op-Amp As An Integrator / Differentiator. , To Calibrate A Polarimeter And Determine The Specific Rotation Of A Sugar Solution Using The Polarimeter. To Analyze Elliptically Polarized Light By Using Babinets Compensator. To Determine The Wavelength And The Velocity Of Ultrasonic Wave In A Given Liquid (Kerosene Oil, Xylene, Etc.) By Studying The Diffraction Through Ultrasonic Grating. To Verify Stefans Law And To Determine Stefans Constant By Electrical Method. To Determine The Refractive Index Of (1) Glass And (2) A Liquid By Total Internal Reflection Using A Gaussian Eyepiece. To Determine The Boltzmann Constant Using V-I Characteristics Of Pn Junction Diode. Verification Of Cauchys Relation By Plotting A Dispersion Curve Using A Prism Spectrometer. Verification Of Brewsters Law And Finding Of The Brewsters Angle. To Construct And, Or, Not Gates Using Diodes And Transistors. To Verify The Operation Of Basic Gates And, Or, Not, Xor, Nor, Nand Using Ics. To Design And Test The Operation Of Half Adder, Full Adder, Half Subtractor, And Full Subtractor. To Design And Test The Operation Of A 4-Bit Binary Adder And Subtractor Using Ic 7483. To Construct And Test Of Sr, D, Jk, And T Flip-Flops Using Ics (Nand Gates). To Design And Test The Operation Of Master-Slave Jk Flip-Flop And Check The Race Around Conditions. To Design 4-Bit Shift Registers (Serial-In-Serial-Out, Parallel-In-Parallel-Out) Using D-Type Flip-Flops. To Design 4-Bit Binary Counters (Asynchronous And Synchronous). To Design Astable And Monostable Multivibrators Using Ic 555 Timer.
Contract Date: Feb 17, 2026 Contract Value : 5.63 Lakh
Local Bodies No of Bidders 6
West Bengal View Result →
44.
Housing Urban and Rular Development #9502542 Technical Bid
Tender For Electrical Work At Thdc Singrauli . - INTERNAL WIRING 2 Point wiring in PVC conduit, with modular type switch :- 3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 4 Group C 5 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 6 Group C 7 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 8 Power plug wiring in PVC conduit (2 x 4 Sq.Mm.) :- 9 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 10 Circuit / Sub main wiring in PVC conduit :- 11 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 12 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. 13 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. 14 2 x 10 sq.mm. + 1 x 6 sq.mm. Earth wire 15 4 x 10 sq.mm. + 2 x 6 sq.mm. Earth wire 16 S/F light plug point Modular Type Accessories :- 17 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 18 S/F power plug point modular Type Accessories :- 19 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 20 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 21 DISTRIBUTION BOARDS & MCBs 22 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 23 Single pole 24 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 25 Supplying and Fixing Following way, Horizontal Type Three Pole and Neutral, Sheet Steel, MCB Distribution Board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 26 6 Way (4 + 18), Double Door 27 8 Way (4 + 24), Double Door 28 Supplying and fixing following way, Single Pole and Neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 29 8 way , Double door 30 12 way , Double door 31 S/F DP MCB Isolator 32 Supplying and fixing following Rating, Double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 33 40 Amps 34 S/F 4P MCB Isolator 35 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 36 63 Amps 37 S/F DP (RCCB) 38 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as Required. 39 40 Amps 40 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 41 S/F MODULAR BOXES, BASE & COVER PLATE :- 42 Supplying and Fixing Following Size/ Modules, GI Box Alongwith Modular Base & Cover Plate for Modular Switches in Recess etc. as Required. 43 1 or 2 Module (75 mm x 75 mm) 44 S/F MODULAR TYPE SWITCH / SOCKET :- 45 Supplying and Fixing Following Modular Switch/ Socket on The Existing Modular plate & Switch Box including connections But Excluding Modular Plate etc. as required. 46 Telephone Socket outlet. 47 TV Antenna socket outlet. 48 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 49 25 mm. 50 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, Unarmored Telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 51 2 Pair 52 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 53 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 54 1 run of cable 55 LIGHTINGFIXTURESANDFANS 56 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 57 Installation, testing and commissioning of pre-wired, fluorescent fitting /compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as Required. 58 Installation of Exhaust fan in the existing opening, including making good the damage, Connection, Testing, Commissioning etc. as Required. 59 Upto 450 mm sweep 60 Fixing Louvers / Shutters for Exhaust Fan: 61 Extra for Fixing the Louvers/ Shutters Complete with Frame for a Exhaust Fan of all sizes. 62 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing 63 CABLE & ACCESSORIES 64 LT CABLE LAYING 65 Laying of One Number PVC Insulated And PVC Sheathed / XLPE Power Cable of 1.1 kV Grade of Following Size Direct in Ground Including Excavation, Sand Cushioning, Protective Covering and Refilling the Trench etc. as required. 66 Upto 35 sq. mm 67 Above 35 sq. mm and upto 95 sq. mm 68 Above 95 sq. mm and upto 185 sq. mm 69 Above 185 sq. mm and upto 400 sq. mm 70 LT CABLE JOINTING & END TERMINATION 71 Supplying and Making End Termination With Brass Compression Gland and Aluminium lugs for Following Size of PVC Insulated and PVC Sheathed / XLPE Aluminium Conductor Cable of 1.1 kV Grade as Required. 72 3½ X 25 sq. mm (28mm) 73 3½ X 35 sq. mm (32mm) 74 3½ X 50 sq. mm (35mm) 75 3½ X 95 sq. mm (45mm) 76 3½ X 120 sq. mm (45mm) 77 3½ X 150 sq. mm (50mm) 78 3½ X 185 sq. mm (57mm) 79 3½ X 240 sq. mm (62mm) 80 MISCELLANEOUS ITEMS 81 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 82 EARTHING 83 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required. 84 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.. (NEUTRAL EARTHING) 85 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 86 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 87 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 88 11KV HT Board, 250 KVA Transformer, 200 KVA DG Set, HT Cable & Accessories 89 H V CABLE LAYING 90 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 91 Above 120 sq. mm and upto 400 sq. mm 92 Supply and making Indoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 93 3 C x 240 Sq.mm 94 Supply and making Outdoor cable end jointing with cast resin compund, including lugs and other jointing materials for following size of 3 core, XLPE aluminium conductor cable of 11KV grade as required. 95 3 C x 240 Sq.mm 96 Supply and Making Straight Through Cable Jointing With Cast Resin Compund, Including Ferrule & Other Jointing Materials for Following Size of 3 core, XLPE Aluminium conductor cable of 11KV grade as required. 97 3 C x 240 Sq.mm 98 RCC Hume pipes 99 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 250 mm dia 101 300 mm dia 102 100 mm dia 103 Manholes 104 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design. 105 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 106 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 107 With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 108 HDPE PIPES 109 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 110 200 mm dia (OD-200 mm & ID-175 mm nominal) 111 CABLE TRAYS 112 Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required. (Cable Tray Bends as per Requirement) 113 150 mm width X 50 mm depth X 1.6 mm thickness 114 300 mm width X 50 mm depth X 1.6 mm thickness 115 450 mm width X 50 mm depth X 2.0 mm thickness 116 600 mm width X 50 mm depth X 2.0 mm thickness 117 EXTERNAL LIGHTING 118 Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. 119 Above 4.5 metre and upto 6.5 metre 120 Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape , Hole Seeling to be done complete as required. 121 32 mm dia 122 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. 123 Upto 35 sq. mm 124 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. 125 Upto 35 sq. mm 126 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 127 3 core 2.5 sq.mm (for6/4 Mtr Poles) 128 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 129 63 mm dia (OD-63 mm & ID-51 mm nominal) 130 TELEPHONE, TELEVISION & DATA SYSTEM (socket,wiring & conduting only) 131 Supplying & Fixing Modular Type Computer jack RJ 45 ISI mark 1 Module on existing Mounting plate and box Complete with all accessories as required. 132 Light Fixtures and Fans 133 Supply of 40W LED Recessed Light Fixture Aesthetically designed 2x2 LED Flat panel light which provides soft-light and glare free symmetrical illumination complete with all accessories as required. 134 Supply of Surface Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 135 Supply of Recess Mounted Energy Efficient, LED Luminaires 12W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 136 Supply of Recess Mounted Energy Efficient, LED Luminaires18W LED DOWN LIGHT (Round/Square) Sutaible for 220v Single Phase Supply complete with driver circuit including making connections etc as required. 137 Supply, of Linear & Compact 10W Mirror Light with Decorative Grey Caps, Polycarbonate Body & Ribbed Opal Diffuser. 138 Supply of LED LuminairesBATTEN20W LED Tube Light of Box Type Prewired Indoor Luminairewith Energy Efficient Electronic Ballast, with End Caps Complete as Required. 139 Supply of Bulk Head Luminaire, heat resistant Glass cover suitable for 10W to 15W LED complete as Required. 140 Supply of Following sweep exhaust fan with guard suitable operation on single phase 230 V, 50Hz. AC Supply, with lowers /shutters in the existing opening. 141 300 mm Sweep 900 rpm 142 Supply & Fixing of 400mm Wall Mounted Fan with all accesseries as required complete for installation. 143 DISTRIBUTION PANELS 144 MAIN LT PANEL 145 NOTE:- MCCBs Wherever Specified shall have Rotary Handle. 146 Suppy , installation, testing, Design, manufacture, supply inspection, handling, assembling, affecting proper connections, testing and commissioningof2mm CRCA sheet steel fabricated cubical type Main L.T. Panel (Totally Type Test Assembled - TTA) floor mounting, dust & vermin proof, front operatedconstruction, enclosure class - IP 52,As per IEC 61439 after proper treatment with 9 tank process with top/bottomremovable gland plates, as required, double compression type cableglands,earth bus, hinged and lockable doorsto achieve dust and vermin proofcomplete with all inter connectionssmall wiring by min. 2.5 sq. mm. FRLS copper wires, ckt labels etc.The panel feeders shall be suitable for terminating suitable nos. 3.5 / 4 core armoured aluminium cable as required. Panel Should Be Internal Arc tested at 50ka for .3 sec as per IEC61641. 147 (Under no case temperature of main LT panel shall be more at any point of the panel. To avoid heating necessary exhaust fans shall have to be provided along with top louvers). 148 Degree of protection IP-42 149 The internal control wiring shall fuse less. All control wiring and metering protection shall be by MCBs. 150 Colour: Siemens Gray Powder Coated or as per approved shade. 151 INCOMER 1 FROM 250 KVA OUTDOOR TRANSFORMER 152 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories. 153 1 set of 3 CTs of ratio 400/5A, Class 1.0 accuracy 15 VA burden for APFCR. 154 Independent manual spring closing mechanism - 1 No. 155 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection - 1Set . 156 Multifunction meter with selector switch with suitable CTs and back up MCBs. 157 3Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required. 158 Shunt trip coil 220 Volt AC. 159 INCOMER FROM DG SET (200 KVA) - 1 Nos 160 1 Nos. 400 amps four pole MCCB of fault breaking capacity 50 KA (Ics=Icu)fitted with interlocked door, automatic safety shutters, mechanical ON/OFF and service/test/isolated position indicator and frame earthing contact ,confiming to IS 13947-21993 as amended upto date complete with following Accessories . 161 1 set of 3 CTs of ratio 400/5A, Class 1.0 162 Independent manual spring closing mechanism - 1 No. 163 Microprocessor release (EMI and EMC certified) for over current, earth fault and short circuit protection- 1Set . 164 Multifunction meter with selector switch with suitable CTs and back up MCBs. 165 Protection releaseswith LSIG and Over voltage ,under voltage,Reverse power protection Relay & Metering & Accessories for each D G set incomers 166 3 Nos. Phase indicatingLED lamps with 2 Amp backup MCB, breaker ON/OFF/Trip indication light with 2A MCB , test terminal block set, MCB , circuits as per standatd practice , auxiallry contact for positive interlocking of the breakers as required . 167 Shunt trip coil 220 Volt AC. 168 1 nos battery charger with DC voltmeter and ammeter suitable for the DG sets (200 KVA) 169 INTERLOCKING 170 Interlocking logic electrical Interlocking betweenincomers and bus coupler and it should have auto start and auto trip facility for Automatic Operation of The Breakers Wit Manual Over Rid Facility 171 BUS COUPLER 172 One Number 400A 50KA 4 poleMCCB as Bus Coupler with ON/OFF Indication. 173 BUS BAR 174 500 A TPN Aluminium bus bar with heat Shrink Sleeve 175 OUTGOINGs 176 All the MCCBs Shall be Equiped/Provided with all accessories & Inbuid protection releas & MCCBs Shall be Thermal Magnetic upto 250A & Above Microprocessor Based with inbuiltO/L & S/C release. 177 1 Nos. 200 AMPSTP MCCB (Capacitor Panel) 178 1 No. 125A 36KA4P MCCB. (Ground Floor Panel) 179 1 No. 125A 36KA4P MCCB. (First Floor Panel) 180 1 No. 125A 36KA4P MCCB. (UPS Panel) 181 1 No. 100A 36KA 4P MCCB (Lift Panel) 182 1 No. 100A 36KA 4P MCCB (Fire Fighting) 183 1 No. 100A 36KA 4P MCCB (Plumbing) 184 1 No. 125A 36KA4P MCCB. (External Lighting) 185 2 No. 125A 36KA4P MCCB (Spare) 186 2 No. 100A 36KA4P MCCB (Spare) 187 Other items such as 188 1 set of control wiring 189 1 Set of designation plates 190 NOTE :- Adequate Quantity of Fire Suppression system with Pneumatic gas cylinder and Heat Sensitive Pneumatic tubing to be used in panel as perthe current fire norms & SURGE PROTECTION DEVICES Type 1 ( Class B), 4 Mode, spar type suitable for 10/350µs surge,3Nos. phase to earth and 1Nos. neutral to earth with impulse Current Iimp. ≥ 50KA Per mode & In ≥ 25kA per Mode. 191 Complete Panel as Above and complete 192 AUTOMATICPOWERFACTORCORRECTIONPANEL(CAPACITOR PANEL) - 90 KVAR- INNOVATION CENTER BLOCK 193 Supplying, Installation, Testing and Commissioning of cubicle type capacitior panel suitable for 415 & 3 phase 50 HZ A.C. supply System fabricated in compartmentalised design from CRCA Sheet Steel of2 mm thick for frame work and cover, 3 mm thick for gland plates i/cpowder coating in approve shade having 500 AMP capacityTPN Aluminium bus bar DMC/SMC bus bar supprot entire pannel should have common Al. earth bar for size 50 mm x 5 mm i/c Providing & fixing following switch gear mounting there on fans,grills for propor ventillation complete with gaskets & inner connection i/c connection with existing CTS in the main CT Panel complete as reqd. The panel board shall be of dust and verm proof with degree of protection IP 42) 194 a) 200 Amps TP MCCB with Microprocessor Based release and E/F proctection with time dely(Ics=100% Icu) - 1 No. 195 b) 250A, 4 strip Tinned Aluminium busbar -1 Set 196 c) Micro processor based automatic Power factor control relay i/c power factor metre in 8 steps 197 d) Multi functional meters with suitable CTS and protection MCBS 1 set. 198 e) 3 Nos. Phase indieating right (lamp) with MCBs protection. 199 OUTGOINGS- 200 1 Set - 63 Amp TP MCB 10 KA and Capacitor duly switching contactor for 20 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 20 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 201 7 Set - 40 Amp TP MCB 10 KA and Capacitor duly switching contactor for 10 KVAR capacity auto mannual selector switch start/stop puch button on/off indicatting lamp with protection MCB & delay timer complete i/c 10 KVAR mixed dielectric with 7% detuned filter copper reactor type capacitor bank with inter Connection 202 complete panel as above and complete 203 GROUND & FIRST FLOOR PANEL (TYPICAL) 204 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 205 INCOMER : 125 AMP 36KA FP MCCB 206 BUS BAR :160 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 207 OUT GOINGS: 208 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 6 209 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 2 210 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 1 211 complete panel as above and complete 212 UPS PANEL 213 SITC of cubicle LT pannel suitable for 415V, 3 phase, 4 wire 50 HZ Ac supply system, fabricated in conmpartmentalized (preferbly) design from CRCA sheet of 2mm thick for frame work and covers, 3mm thick for gland, plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having suitable Amp capacity extensible type TPN aluminium alloy bus bars of high conductivity, DMC/SMC bus bar supports, , bottom base channel of MS section not less than 50mm x 50mm x 5mm thick,entire pannel shall have a common copper earth bar 25mm x 5 mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AI. bus bars and control wiring with 2.5 sq.mm. FRLS PVC insulated copper conducter S/C cable, cable alleys, cable gland plates in two half. i/c providing following switch gears :- 214 INCOMER : 160 AMP 25KA FP MCCB (Including BY Pass Switch for 50 KVA UPS) 215 BY PASS Switch for UPS 160 AMP FP- 1 no. 216 BUS BAR :200 AMP,500 Volts, 3 phase 50 HZ4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. 217 OUT GOINGS: 218 63 AMP 4P MCB Including 1 no. of Indication Lamp (DBs) - 7 219 40 AMP DP MCB Including 1 no. of Indication Lamp (DBs) - 2 220 63 AMP 4P MCB Including 1 no. of Indication Lamp - 2 221 100 AMP 4P MCCB Including 1 no. of Indication Lamp - 1 222 63 AMP 4P MCB with1 no. of Indication Lamp (Spare) - 1 223 40 AMP DP MCB with1 no. of Indication Lamp (Spare) - 2 224 complete panel as above and complete 225 LIFT PANEL 226 Design, manufacture, supply, installation, testing and commissioning of cubicle type panel fabricated out ofCRCA sheet steel , floor mounted totally enclosed switchbaord suitable for use of 415 volts , 3 phase, 50 HZ completewith aluminium bus bar and all accessories including supply and fixing of following incoming and outgoing switchgears, Panel Should Have Double Earthing Provision which connected to the nearest earth grid. 227 INCOMER :100 AMP FP MCCB 228 BUS BAR : 125 AMP, 4P high conductivity electrolytic Aluminium bus bar of suitable length, insulated by heat shrinkable sleeves. The current density of bus bar shall be minimum 0.8 sq mm / amp. 229 The Maximum allowable temperature for the Bus bar to be restricted to 90 deg C. The temperature rise should be restricted to 45 deg C above ambient temperature. 230 OUT GOINGS: 231 1 No 63 AMP 4P MCB(Lift) 232 1 No 40 AMP DP MCB(Machine Room DB) 233 1 No 40 AMP DP MCB(Spare) 234 1 No 63 AMP 4P MCB(Spare) 235 complete panel as above and complete 236 EXTERNAL LIGHT FEEDER PILLAR 237 Design,Manufacture, Supply, Installation,Testing and CommissioningofPanelFabricated out of 16 SWG CRCA sheet steel,IP 54, wall / floor mounting type with rain canopyThe sheet steel shall undergo minimum 7 tank treatment followed by finishing powder coating of min 60 micron thickness. the board includes415 /240 V electrolitic Aluminium Bus Bar, removable gland plates, cable glands,including connection with outgoing feeders completeinall respect, Panel Should Have Double Earthing Provision Which Connected to the Nearest Earth Grid. 238 INCOMER: 239 1 no. 125A, 25KA 4P MCCB with microprocessor based releases, ON indication, 1 no. multifunction meter (showing all power parameters), with Selector Switch, Matching Cast Resin CTs. + 3 Nos 63A DP MCB For each Phase.with 3 Nos Astronomical Weekly programmabletime switch (SST- 1min) ON Phase for automaitc switching of landscape light fixtures at sun set and sun rise or twilight (auto on/ auto off and auto mode) with manual override faiclity with 12/24 hour display format with suitable battery and indication for relay status i/c programming at site. 240 BUS BAR 241 TPN Aluminium bus bar with heat Shrink Sleeve rated for 125A. 242 OUTGOING 243 18 nos 16A DP MCB 244 2 nos 40A DP MCB 245 1 nos 40A 4P MCB (SPARE) 246 Other items such as 247 1 Set of control wiring 248 1 Set of designation plates 249 All Items complete as above 250 CABLE & ACCESSORIES 251 Supplying of Following Sizes of 1.1 KV Grade MulticoreAluminium Conductor XLPE Power Cable Insulated armoured cable conforming to IS:7098 (Part - I) or as per Relevant IS Code complete with all Amendments etcand should be NABL certified as required. 252 3.5 C X 240 Sq.mm Al. XLPE arm. 253 3.5 C X 185 Sq.mm Al. XLPE arm. 254 3.5 C X 150 Sq.mm Al. XLPE arm. 255 3.5 C X 120 Sq.mm Al. XLPE arm. 256 3.5 C X 95 Sq.mm Al. XLPE arm. 257 3.5 C X 50 Sq.mm Al. XLPE arm. 258 3.5 C X 35 Sq.mm Al. XLPE arm. 259 3.5 C X 25 Sq.mm Al. XLPE arm. 260 MISCELLANEOUS ITEMS 261 SITC of CO2 Fire Extinguishers 4.5 kg capacity complete in all respect ISI : 15683 marked. As per Safety plus extinguisher fire carbondioxide 4.5kg, duly charged, portable and complete as per defence specification (safetyplus SPEC 4.5) 262 UPS 263 UNINTERRUPTED POWER SUPPLY (UPS) - 50 KVA 264 Supply of 50 Kva Online UPS, IGBT UPS(Transformer-less Design). 265 Supply of SMF Batteries (12Volt VRLA, 120 Ah, 28 Numbersto provide 30 Min Backup in total for 50 kva UPS at 0.8PF and ECV=1.7V. 266 Fully rated Inbuilt static switch at the inverter output and 100% rated Inbuilt static switch at the static bypass line integrated in UPS module. 267 Supply of Local Accessories (like Cabling Between UPS and the Battery onsidering Cable Routing ,Battery Interlinks , Battery Rack etc). 268 Backfeed protection at Mains & Bypass (Inbuilt / External). 269 Installation and Commissioning of 50 kVA UPS, Battery and Accessories. 270 Supply , installation , testing and commissioning 160A FP MCCB of25KA breaking Capacity in metal sheet enclosure with ON/OFF, TYB Indication lamps for Incoming of UPSComplete in All Respect as Required. 271 SUB STATION - 11KV HT BOARD, 250 KVA TRANSFORMER, 200 KVA DG SET, HT CABLE & ACCESSORIES 272 11KV SINGLE VCB PANEL BOARD 273 11KV SINGLE PANEL HT VCB (Indoor Type) - ONE INCOMERS CUM OUTGOING 274 Design, Manufacture and Supply of 1 Panel, 11 kV HT VCB Switch Board with Following Accessories : 275 Incoming Cum Outgoing 276 Indoor Type - 630A, 11kV, 350MVA for 3 Sec., TP, Horizontally isolated, horizontally drawout type, motorised spring charged, closing mechanism, motor voltage 230V AC, shunt tripping & Closing coil Voltage 24V DC, Electrically Operated, Trip Free, Dust & Vermin Proof, Vacuum Circuit Breaker (VCB) With Mechanical & Electrical OFF/ON Indicators & Provided with Following -1 No. 277 CT chamber with double wound single phase, cast resin CT, 15VA burden with core-1 for metering (CL-1) and core-2 for protection (CL-5P10) and of 60/5/5A ratio - 3Nos. 278 IDMT relay with 3 elements for over current (50-200%) and 1 element for earth fault protection(10-40%). - 1 Set 279 Anti Pumping Relay - 1 Set. 280 Master Trip Relay - 1 Set. 281 Trip circuit supervision relay - 1 Set. 282 Potential Transformers, 3 Phase, 3 Limb,Drawout Type, Resin Cast 11000/(Root 3)/110/(Root 3) Ratio Class 1 Accuracy, 100 VA Burden, with HV fuse on primary side and MCB/ MPCB on secondary side. - 1 Set 283 6 Windows Annunciator with Hooter - 1 Set 284 1 Window for over current trip - 1 Set 285 1 Window for earth fault trip - 1 Set 286 1 Window for master trip relay - 1 Set 287 1 Window for Emergency Stop Push Button - 1 Set 288 2 Windows Spare - 1 Set 289 Digital Ammeter with inbuilt selector switch - 1 Set 290 Digital Voltmeter with inbuilt selector switch - 1 Set 291 A set of breaker ON/OFF/Trip/DC control supply healthy/Trip circuit healthy/ Spring Charged VCB in test / VCB in service & R,Y,B phase indication lamps. - 1 Set 292 Emergency stop push button -1 Set 293 Limit switches with 6 NO/ 6 NC breaker auxiliary contacts - 1 Set 294 Control:- T-N-C (Trip, Neutral, Close) breaker control switch with indication arrangement. - 1 Set 295 All control wiring with protection & test terminal block as required. - 1 Set 296 Space heater with thermostat for moisture absorption. - 1 Set 297 Suitable for connection to 3C x 240 sq.mm. Cross linked polythelene(XLPE) 11kV cables or as called for. - 1 Set 298 Cable box for 3C x 240 sq.mm 11kV XLPE Al. conductor cable. - 1 Set 299 HT Danger Plate - 2 Set 300 Incoming as described above. 1 Sets 301 Powerpack as Required to Be Included (220V/24V DC), 7AH Battery for Each Breaker Module. 302 SINGLE PANEL 11KV HT VCB PANEL AS DESCRIBED ABOVE 303 11KV TRANSFORMER(11 KV /0.433 KV) (250 KVA) 304 11KV TRANSFORMER(11 KV /433 V) (250 KVA) 305 Supply Installtion, Testing and commissioning of outdoorOil cooled Outdoor Type Transformer11 KV/433 Volt Rating 3 phase, Double Wound with copper Winding.(as per IS : 1180 (part 1) : 2014Level 2 (AMENDMENT 4)/ Equivalent IEC Standard , OLTCin Steps (+10% to -10% @ 1.25%), Insulation Class : Class A , Temperature Rise : 40 Deg.c in Oil , 45 deg.c by Resistance, 50 deg.c by Ambient , Dyn 11 Vector Group and other Standard Accessories as Required Including Followings : 306 PLEASE NOTE THE TRASNFOREMR SHALL BE IN COMPLINACE WITH NEW REGUALTION IS 1180 or Equivalent IEC Standard FOR LOSSES AND EFFICIENCY and ammended upto date 307 Civil work shall be paid extra as per actual. 308 Cable Termination box with disconnecting facility for 11 KV 3C-240 sq mm XLPE cable at 11 KV side 309 ON Load Tap Changer on HV side+10% to -10% @ 1.25%. 310 Standard Fittings , Accessories /Spares :- 311 Rating and Terminal Marking Plate - 1 312 Earthing Terminals - 2 313 Lifting Lugs - 2 314 Drain Valve with Blanking Plate - 1 315 Filter Valve with Blanking Plate - 1 316 Conservator - 1 317 Conservator Oil Filling Hole With Cap - 1 318 Oil Level Indicator with Min. Marking - 1 319 Dehydrating Breather - 1 320 Conservator Drain Plug - 1 321 Air Release Device - 1 322 Pressure Relief Valve - 1 323 Thermometer Pocket - 1 324 Rollers uni directional - 4 325 Radiators Detachable - 4 326 HV Cable Box- 1 327 LT Cable Box - 1 328 Seperate Neutral Terminal - 1 329 ON Load Tap Changer - 1 330 OTI with alarm and trip contacts 331 Buchholz relay with alarm & trip contact 332 Current Transformer 333 Radiator Valve 334 Marshalling Box 335 WTI with alarm & trip contact 336 WTI Pocket 337 Drain Valve with Blanking Plate (OLTC) 338 Filter Valve with Blanking Plate (OLTC) 339 OLTC Surge Relay 340 RTCC Indoor 341 AVR 342 250 KVA (11/433V) AS DESCRIBE ABOVE 343 DIESEL GENERATOR SET - 200 KVA DG SET :- 344 200 KVA DG SET 345 Supply, intastallation, Testing & Commissioning of200 KVA Capacity Radiator cooled DG Set with Suitable StandardAMF Panel & suitable capacity engine directly coupled withalternator for 415 volt, 3 phase, 50 Hz, 4 wire, Generation system complete with accessories, Fuel Oil Tank & Control Panel etc as Required and sound proof acquastic enclosurefor the DG SET (75 db @ 1m) , including supply,fixing of antivibration pads suitable for 200 KVA DG Set as per standards of Engine manufacture, provision of conrol cablefrom engine to control panelto engine. Provision of pipe fuel pipe line of suitable size from fuel tank to engine and over flow pipe engineto fuel tank complete gatevalve and fitting leader maker etc. Supply , Intallation of starting batteries of suitableAH as recommended by manufacterer Heavy duty complete as required at site complete with stand and battery charger residentials silencer sutaible for diesel engine exhaust pipe line complete complete flange, bend, flexible pipe all as required and as directed by Engineer Incharge. 346 Diesel Engine (CPCB-4 NORMS COMPLANT) 4 Stroke, Radiator Cooled, Diesel Engine Model Developing Output Prime 160 KW Having Following Arrangement :- 347 Flywheel With Starter Ring for Generating Set 348 Air Filter , Lube Oil Cooler Assembly with Accessories. 349 Exhaust Air Manifold 350 Exhaust Bellow 351 Fuel Fiter 352 Diesel engine pre heating arrangement 353 Lube Oil Filter 354 Exhaust Gas Turbo Charger with After Coller 355 Day Tank For fuel with Markings 356 ECP Panel mounted on a Separate Frame. 357 Radiator with Pusher Type Fan, With Fan Guard, Coolant Pump. 358 12V Electrical Starting System with Starter Motor and Battery Charging Alternator. 359 Engine Mounting Supports 360 ALTERNATOR Rated at 200 KVA, 415 Volts, 3 Phase, 4 Wire, 0.8 P.F (lag), 50HZ, 1500 RPM, IN Accordance with IS 4722 /IEC 60034 as per following Specification. 361 Rating: Suitable for an over-load of 10% for 1 hour in every 12 hours operation. 362 Voltage Regulation: Provided with Fast Response Thyristor Type Electronic automatic voltage regulator, which holds output voltage within desired limits. (+/- 1%). 363 Excitation: Self Excited - Self Regulated. 364 Alternator Loading: Suitable for Taking Rated load Immediately After Machine Reaches Rated Voltage and Speed. 365 Vibration: Suitable for Direct Coupling with Engine and Mounted on Common M.S. Channel Base Frame. 366 Enclosure: Screen protected drip proof enclosure with IP – 23 degree of protection. 367 Cooling: Air Cooled type with radial fan mounted on Rotor. 368 Winding and Insulation: Insulation class H as defined in IEC – 60034-1 369 ACCESSORIES :- 370 MS Base Frame Suitable for Mounting of the Offered Engine and Alternator. 371 Day Fuel Tank of Standard Capacity as per Rating Complete Fuel Gauge, Inlet/Outlet Connections, Drains Plug, Etc. 372 Residential Silencer (1.5 Meter with 750 mm diaApprox) Including Insulation of Silencer. 373 2 Nos 12 Volts DC Battery of Suitable Capacity with Leads. 374 1 Set of AVM Pads Fitted in Base Frame. 375 TOTAL FOR 200 KVA DG SET 376 Supply of H.T. Cable 377 Supply & Testing of following 11 KV (E) grade multicore Aluminium conductor XLPE insulated cable, insulation screening withextruded semi conducting compound in combination with copper tape armoured cores laid up, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS: 7098 (Part - II) and complete with all latest amendments etc. complete as required. 378 3 C x 240 Sq. mm11 KV (E) 379 Supply , Installation, Testing & Commissioning of Integrated Post Top Lantern With 40W LED Lampincluding Pole &connection with 3 x 2.5 sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 380 Supply , Installation, Testing & Commissioning of 50 W LED withcomplete with pot optic reflector connection with 3x2.5sq.mm single core PVC insulated copper conductor cable from junction box to fixture as required. 381 Supply, Installation, Testing and Commissioning of 200x160x98 (KVPC) Polycarbonate thermoplastics enclosure - junction box with I.P - 65 Protection with Terminals &cable hinged cover of approved design complete having gasket of internally embedded & made of polyeutherene & should be weather proof, rust proof, dust proof, water proof - box shall be tested as per IEC - 60670-2/60670-22. the box shall have self threaded holes & provision for mounting din rail. with 2 Nos cable gland including supplying & fixing crimping 2 nos lugs & 1 nos 32A connector 6 way for looping the incoming & outgoing cables and also connection of the street light one 6A SP MCB Including Connection of 2x6 sqmm Cable etc as Required. 382 Supplying of 6 mtr long hot dip Galvanized octagonal Pole with top of the pole 70 mm dia (A/F) and bottom of the pole 130 mm dia (A/F) made out of 3mm sheet with MS base plate of size 200mm (NS) x 200mm (NS) x 16mm (NS) on precast RCC foundation complete with suitable size openinginside the pole with flush weather proof door with locking facility preferably with LN key having proper arrangement with Accommodating of 1 Nos. 6 Amp.,10 KA MCB & neutral link4 way connector suitable for 25 Sqmm cable complete with electrically safe including inside cable termination with thimbles i/c wiring from pole box to fitting with 3x1.5 sq.mm. FRLS PVC insulated copper conductor wire, earth connection, din channel, earth stud and other accessories pertaining to this pole (But without street light fitting) etc as reqd.including providing & laying in position suitable RCC foundation as required for 6 mtr. octagonal hot dip Galvanized Pole as per Manufacturers drawing with 1:1.5:3 concrete (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) including excavation of all kind of earth such as all type of soil/soft rock or hard rock etc. as per existing site condition i/c providing, cutting, bending and placing reinforcement & IncludingJ typefoundation bolts , anchor plate and templates in position as per manufacturer Standard and Providing PVC Pipe for Cable Entry and Exits Including Disposal of Surplus Malba / Softrock / Hardrock Stone etc.as Required. 383 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing laid in ground including cost of digging upto required depth, 150 mm sand all around the cable, brick protection and back filling, clamped to wall with suitable clamps including saddles fixing bolts, Connection Testing and commissioning as Required. 384 2x6 sqmm 385 Supplying of Following sizes 1100 volt grade XLPE insulated PVC sheathed aluminium conductor armoured cables as per specification in existing trenches/pipes, cable trays, ducts, clamped to wall with suitable clamps including, saddles fixing bolts, connecting testing and commissioning as Required. 386 2x6 sqmm 387 Supply, Installation, Testing and Commissioning of 120w Flood Light, Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP65 flood light, suitable for highlighting architectural facade and general purpose lighting. 388 SOLAR POWER SYSTEM 389 Supplying, installation, testing and commissioning of Grid interactive roof top solar photo voltaic power generation system including space frame 390 (SCHEDULED ITEMS - AS PER DSR (E&M) 2022 391 (A) Supplying , installation , testing and commissioning of electric driven terrace pump suitable for automatic opeartion and consisiting of the following, complete in all respects as required:( Terrace pump) 392 (B) Horizontal type, multistage, centifugal, split casing pump of cast iron body & bronze impeller with stainless shaft, mechanical conforming to IS:1520 393 © Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 hz, AC supply with IP55 clas of protection for enclosure, horizontal foot mounted type with class-F insulation, conforming to IS-325. 394 (d)M.S fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required. 395 (E)Suitbalecement concrete foundation duly plastered and with anti vibration pads. 396 Discharge : 450 liter per minute 397 Head : 35 meter 398 Providing, laying, testing & commissioningof C class heavy duty MS pipe conforming to IS 3589/IS 1239 including welding, fittings like elbows, tees, flangers, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 399 100 mm dia 400 Providing, laying, testing & commissioning of B class medium duty G.I. pipe conforming to IS 1239 including welding, fittings like elbows, tees, flanges, tapers, nuts, bolts, gaskets etc, and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required: 401 100mm dia 402 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type-A) with blank Gunmetal/Stainless Steel cap and chain as required: 403 Single headed Stainless steel. 404 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required. 405 100 MM NB 406 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required 407 100 NB 408 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange 409 100 mm dia. 410 Supplyinig and fixing 63 mm dia , 15 mm long RRL hose pipe with 63 mm dia male and female couplings duly bound with GIwire , rivets etc.confirming to IS 636 (type-A) as required: 411 Supply, fixing first aid Hose Reel with MS costruction spray painted in post office red , conforming to IS 884 complete with the following as required 20 mm nominal internals diawater hoseThermo plastic (Textile reinforced) type -2as per IS 12585) 20 mm nominal internal dia gun metal globe valve & nozzle Drum and brackets for fixing the equipments on wall .connections from riser with 25 mm dia stop gun metalvalve & M.S . Pipe and socket.40 M 412 Supplying and fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS 903 Suitable for instantaneous connection to interconnect hose pipe coupling as required:Stainless steel (Grade 304) 413 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 414 2 way-100 mm dia M.S. Pipe 415 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. 416 TOTAL- A(SCHEDULED ITEMS - AS PER DSR E&M 2022) 417 (NON SCHEDULED ITEMS - AS PER MARKET RATES) 418 Supply & erection of ISI marked portable fire extinguishers, confirming to IS:15683, wall mounted type, wall brackets complete in all respect as per standard item with all accessories, delivery hose & nozzle whereever required, including fixing on walls as per the directions ofEngineer-in-charge. 419 Water CO2type. 9 Lt. capacity 420 D.C.P.Type 6 kg. capacity 421 ABC dry powder Type 6 kg. capacity 422 CO2 gas type. 6.5 kg. cap. -Trolley mounted 423 Providing & fixing neoprene rubber double flangedrubber expansion joint(anti vibration bellow) of standard length as per manufacturers specifications. suitable for hydrostatic test pressure of 21 kg/sqcm including all necessary fittings i.e. rubber gasket, nuts, bolts, washers etc complete as required. 424 100 mm dia. 425 150 mm dia. 426 Providing & fixing standard carbon steel fireman axe with rubber insulated handle tested to 20000 Volts. 427 Supply, fixing, testing & commissioning of 25 mm dia inspecting and testing assembly with gun metal valve, sight glass, by pass valve and connection to the drain line as required to complete the system. 428 Providing and fixing of cast iron body 100 mm dia Draw out connection in Under ground water storage tankwith heavy class MS suction pipe of required length,foot valve, suction coupling in conformity with local regulations complete in all respects. 429 Providing and fixing weather proof standard fire hose cabinet (750 mm x 600 mm x 250 mm)outdoor typemade of not less than 16 SWG MS sheethaving glassed hinged door (5 mm thick glass) including necessary locking arrangement with handle for housing two nos.15 meter long fire hose pipes, branch pipeas required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coat of fire red colour). The cabinet shall be mounted onself standing mounted type MS Angle iron frame as required. The words FIRE HOSE to be painted on the box. 430 Providing and fixing standard fire hose cabinet door with frame (900 mm x 2000 mm ) or (suitable to fit in the duct made of not less than 16 SWG MS sheethavingglass hinged door (5 mm thick glass) including necessary locking arrangement with handle as required as per drawings, including brackets for mounting accessories, painting (one coat primer and two coats of fire red colour). The door shall be fixed in the masonry wall or as required. The words FIRE HOSE to be painted on the box. 431 Supply, installation and testing of cylindrical type flanged pressurevessel tank, 450 mm dia, 2 m long and of 10 mm thick M.S., common for a set of fire pumpsincluding flanged connection, suitable supporting legswith MS plate of size 75x75x5 mm at the bottom and grouted in CC foundation. The air vessel tank shall be provided with air release valve, stop cock, safety valve, pressure gauge, 50 mm dia drain valve, suitable length of connecting pipe and valve from delivery header to vessel tank, suitable pressure switches to operate all pumps (1 nos each), tested to min 25 KG/cm2complete including painting with synthetic enamel paint of approved shade with all accessories as per direction of the Engineer-in-charge. (For Pump House) 432 Providing & fixing 100 mm dia dial pressure gauge including making connections with MS pipecomplete in all respects. 433 PART-A EQUIPMENT 434 OUTDOOR UNITS (HEAT PUMP TYPE) 435 Supplying,installing,testingandcommissioningofaircooled variable refrigerant volume / Flow modular typeairconditioning system with R410a refrigerant. The PCB Chamber of outdoor unit should be refrigerant cooled suitable for 415±10% 3 Phase, 50 cycles. The unit shall consist of indoor and out door units withindividual controllerasperdetailgiveninspecifications andhaving followingitems:(Theseitemsareto be giveninIndian rupeeswithcustomduites,inlandfrt,clearanceetconSitebasis) 436 Modular type outdoor units equippedwith highlyefficient 100% inverter type hermitically sealed scroll compressors, minimum two comprossors for and above 14 HP modules, with special precoated heat exchanger, low noise condenser fan housed in compact housing duly powder coated and manufacturer of compressor and outdoor unit should be same. The Unit should have automatic refrigerant charge function. The static pressure of the outdoor unit shall be more then78Patoavoidhotairrecirculation.The unitshallbeabletooperateuptoto45°Cin coolingmode.The unit shall also have feature to automatically modulate the evaporative temperature between 6 deg C to 11 deg C with respecttoloadforbettercomfortandenergy efficiency etc complete as reqd. The units should have free phase technology for countinued operation. The unit shall deliver the rated capacity at AHRI Conditions and work even at 50°C ambient temperature without tripping .The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.5 of following capacitites: 437 Cost of R 410 A Gas should be inclusive 438 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring from near the indoor and outdoor units respectively. 439 The outdoor unit should include all loading, unloading, transportation, power cabling/wiring,( Y/T joints which is required for ODU Zone requirement Modules) from near the indoor and outdoor units respectively. Outdoor Units-Heat Pump , Fully Gas Charged and Aluminum fins within the ODU (condensing) unit shall be coated with polysiloxane based coating. 440 The Vendor should considere the deration on ODU election as per Singroli MP Ambient conditions 441 18 HP Outdoor unit VRV/VRF Zone-01 442 16 HP Outdoor unit VRV/VRF Zone-02 443 22 HP Outdoor unit VRV/VRF Zone-03 444 26 HP Outdoor unit VRV/VRF Zone-02 445 INDOOR UNITS 446 Supply, installation, testing and commissioning of following minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cord less remote control etc., suitable for operation on single phase 230 V ±10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree CDB and 19 Degree C WB temperature. 447 Ceiling Mounted Cassette Unit 448 300-318 CFM / 0.63-0.80 TR 449 310-335 CFM / 1.0 TR 450 600-670 CFM / 1.2-1.3 TR 451 812-830 CFM / 1.6-2.0 TR 452 850-865 CFM / 2.5-2.8 TR 453 1130-1165 CFM / 3.1-3.2 TR 454 Ceiling Mounted HSP Ductable Unit 455 1130 -1150 CFM / 3.0-3.40 TR 456 1200-1377 CFM / 3.95-4.0 TR 457 1600-2050 CFM / 4.5-5.5 TR 458 2047-2295 CFM / 6.36-7.1 TR 459 REMOTE CONTROLLERS 460 Supply, installation, tesing and commissioning of Imported Remote controllers (Corded) for operation of ductable indoor units and AHUs. 461 Touch screen controller for indoor units controller - VRV 462 Supply, installation, testing and commissioning of touch screen controller (Which is controlled 45 nos. indoor units in terms of ON/Off Status, temp. Status, Fan Speed, ODU On/Off Status etc.) with all accessories and controls. 463 REFNUTS /T/ Y-JOINTS 464 Supply, installation, tesing and commissioning of Imported fittings Y-joints insulated, distributer and headers for all Indoor units at both the ends floors layout as per layout drawings.All interconnecting joints, Y Joints withpolysiloxane based coating 465 REFRIGERANT PIPING 466 Supply, installation, testing and commissioning of Interconnectingrefrigerantpipe work with (13/ 19mm thick) cross linked closed cell Oxide Acetate Foam tubular insulation between each set ofindoor & outdoor units asper specifications, allpiping inside the room shall be properly supported with hangersandv All interconnecting Copper piping, joints, U bends withoxycoat dual barrier coating shall run incable tray. (Note: Ref. Piping Length may be review as per site routing) 467 06.35 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 468 09.52 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 469 12.70 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 470 15.88 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 471 19.05 mm with 13 mm thick cross linked closed cell Oxide Acetate Foam insulation 472 22.22 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 473 28.58 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 474 34.92 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 475 41.30 mm with 19 mm thick cross linked closed cell Oxide Acetate Foam insulation 476 TRANSMISSION & CONTROL WIRING 477 Supply, installation, testing, termination and commissioning of control cum transimission wiring (should be shielded cable in PVC Pipe) of 2C x 1.5 Sqmm Cu between indoor unit and out door unit and indoor units and its remote controller. 478 2C x 1.5 Sqmm Cu Cable or as per Manufacturer OEM 479 Perforated GITray with hangers & supports for copper piping (250 mm wide) 480 Refrigerant-410a 481 Supply , charging & Leackage testing of refrigerant -410a in additionalcopper piping circuit. 482 CONDENSATE DRAIN PIPE 483 Supplying, fixing,testing and commissioning offollowing PVC pipes for condensate drain duly insulated with Fire rated Class O kinny foam /Nitrile Rubber & vapour barrier duly secured with adhesive tape as per specification ,cut to required length and installed with all joints , including the necessary fittings. (For all the AHU/FCU units upto the main header in the shaft dor vertical risers) 484 65mm dia 485 50mm dia 486 40mm dia 487 30mm dia 488 25 mm dia 489 TOTAL CARRIED OVER TO SUMMARY ( PART-A EQUIPMENTS) 490 PART-B VENTILATION 491 Propeller fan 492 Supply,installation,testing and commissioning of Certified Propeller fan of the following capacity of approved make and specification. Fan shall be supplied with aluminum gravity louver & bird screen and Speed Regulator. 493 200 mmdia propeller fan,with single phase motor 494 300 mmdia propeller fan,with single phase motor 495 450 mmdia propeller fan ,with single phase motor 496 Inline fan 497 Supply, installation, testing and commissioning ofCertified Circular/Rectangular swing type Inline fan with fiire retardent Canvas connection Speed Regulatorof the following capacity of approved make and specification. 498 100-300 CFM,5-7 mm SP WG with Single phase motor 499 350-400 CFM,10-12 mm SP WG with Single phase motor 500 600-800 CFM,10-12 mm SP WG with Single phase motor 501 Tube Axial Flow fans 502 SITC of Long case Tube axial flow fans, as per specifications and approved makes suitable for three phase operation respectively Normal/Smoke case. 503 SITC of AMCA Certified (For Air and Sound Performance) tube axial flow fan of different capacity as mentioned below in standard M.S.contruction. Entire fan model & AMCA Seal shall apear in techncial submittal of fan. All the fans are synthetic enamelled panited/hot dip galvanized with minimum 220 GSM Zinc Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage induction motor (IE-2 type) confirming to IS - 325-IP - 55 with class `F insulation.Fan efficiency should not be less than 70 %, noise level should not be more than 85 db @ 3 m distance when measured in hemisperical reverberant room conditions. Fans should be as per specification and drawings. (As per Vent. Fan Schedule ) (Makeup Air & Pressurization Fans with St. Press. of 40 mmWG/Make Up Air Fan at 30mm WG) 504 6000 CFM (For Stairwell/Liftwell Pressurization) 505 6500 CFM (For Smoke Extract,with H Class insulation) 506 AIR SIDE WORKS 507 Site Fabricated Duct - GI duct 508 Supply,Installation,balancing and commissioning of fabricated at site GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 509 0.63mm (24 gauge) GSS 510 0.8 mm (22 gauge)GSS 511 Factory Fabricated Duct - GI duct 512 Supply,Installation,balancing and commissioning of factory fabricated GSS sheet metal ducts (rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter,vanes, hangers, Gripple supportsetc.) in accordance with the approved shop drawings and specifications , and shall also confirm to the BIS specifications.The duct shall be fabricated at site for to suit pieces. 513 0.63mm (24 gauge) GSS 514 0.8 mm (22 gauge)GSS 515 Supply, Fabrication, Installation and testing of Insulated Al. Flexible ducts in accordance with the approved shop floor drawings and specifications and shall also confirm to the BIS specifications. 516 200 mm Dia. 517 150 mm Dia. 518 Grilles/Diffusers 519 Supplying and fixing of Extruded aluminium supply and return air grilles/diffusers/louvres with dampers, supply air plenum etc. duly powder coated as per specifications and drawings. 520 Aluminium supply air grilles with damper. 521 Aluminium return air grilles without damper. 522 Aluminium supply air square diffuser with damper 523 Aluminium return/exhaust air square diffuser without damper. 524 Aluminium return/exhaust airValve circular/squirell diffuser without damper. 525 Fresh Air/Exhaust Air Louvers 526 Supplying and fixing ofextruded aluminium louvres with frame bird screeen , mounting arrangement etc. as per specifications and drawings. 527 Fresh Air/Exhaust Louvers 528 Supply,Installation,Testing and commissioning of doble layer canvas connection with 1/2 hr. fire ratingasper specification. 529 MECHANICAL INSULATION 530 DUCT LINE ACOUSTIC TREATMENT 531 Supply and installation of cross linked open cell Oxide Acetate( AccoIsolate) Foam Acoustic insulation on ducts having density of 30 to 60Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 532 15mm thick Oxice Acetate Acco IsolateAcoustic open cell insulation on one side for Duct acoustic insulation 533 DUCT LINE THERMAL INSULATION 534 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 535 25 mm thick insulation oxide acetatefoam with 2 coat layer of 7 mile cloth with starbond or eql. adhesive on Exposed supply air duct 536 13 mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 537 9mm thick insulation oxide acetatefoam laminated with aluminium foil supply air duct 538 EXPOSED ROOF INSULATION 539 Supply and installation of cross linked closed cell Oxide Acetate( Thermo Isolate) Foam Thermal insulation on ducts having density 0f 30 ±3Kg/ M³ ,having K value 0.029 W/m ° K at 0°C Deg temp and temp range of-70°C to +100°C and fire rating Class O as per BS 476 Part 6 fromCBRI,Roorkee and CFC/HCFC free as per US EPA 5021 A(2014 ). • Smoke & Toxicity index of material shall be passed as per IMO MSC 307 ( 88 ) 2010 Anexx 1 Pt 2 andas per the approved specifications. 540 19mmthick oxide acetate insulation for underceck plain 541 TOTAL CARRIED TOSUMMARY(Mechanical Insulation works) 542 ASSOCIATED ELECTRICAL WORKS 543 Therates for the distribution boards from the Breakers andinstrumentsshall also include the following : 544 Wiring forlight / Fan points with 1.5 sq. mm PVC insulatedcopper conductor1100 Volt grade strandedflexible FRLS wiresofapproved makein1.6mmthick25mmdiaMS conduitincluding costof providing & fixing saddles, hangers, supports, cutting chases and filling chases for recessed conduiting, and including the cost of providing and fixing a6 amp240Volt ModularPlatetypeswitchesof approved quality,colour, makeanddesign with mouldedcover platein zinc chromate passivated MS box and including the cost of running 1.5 sq. mm PVC insulated copper earth wire for loop earthing etc. complete 545 TPN ACB’s / MCCB’s shall mean 3 pole ACB’s / MCCB’s with adequatesize of neutral link. 546 All MCB’s shall be of minimum 10 KA breaking capacity and MCCB s shall be not lessthan 25KA 547 The breaking capacity of MCCB’s are mentioned panel wise. All MCCB’s shall be with thermalmagnetic microprocessorreleasesas per BOQand following : 548 i.MCCB rating upto 250 Amps with thermal magnetic releases. 549 ii. MCCB above 250 Amps with microprocessor releases. 550 All MCB’s used for protection ofresistiveand lightlyinductive loadshallbetype “B”characteristic and inductive(motor)loadshall be of type “C” characteristic. 551 Degree of protection for following type of distribution panel enclosureshall be as per IS:13947-1993. 552 i.IP 42 for indoor panels. 553 ii. IP 55 for ODU panel. 554 AllMCCB’sshall beprovidedwithoperatingmechanismfordoorinterlock. 555 All hinged door shall be earthedthrough2.5 sq mm tinnedbraidedcopper wire. 556 Providing cableclamps/ supportswithin distributionboardscablealley. 557 Current density of aluminium shall be 1sq mm for 1.0 Amps for ratedcurrent of bus bars. 558 Model, current capacity location and frame size of switchgear shall be writteninside of thepanel doors with paint / permanent marker asapproved shop drawings / site requirment. 559 All meter shall be digital type and all starter shall be as per Type-2 Coordination chart 560 Current Transfomer shall be resin cast. 561 All Panel Shall be BMS Compitable 562 AHU/Fan Panel 563 Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of following LT panels fabricated out of 14 guage CRCA sheet steel in cubical formationwith reinforecment of suitable size angle iron and channel T iron flats. All steel material used in the construction of panels shall be powder coated. A solid busbar shall be provided at the bottom of the panel with two connecting eyes for termination. The boards shall be suitable for 415 volts, 50 Hz, 3 phase , 4 wire supply system. All the hardware used in the fabrication of the panel shall be galvanized with zinc passivation. The panel shall be compartmentalized to accommodate one feeder in each compartment. A vertcal cable alley of suitable width shall be provided to serve on or two vertical feeder sections. Also the opening between the busbar chamber and the feeder section shall be shrouded with bakelite / hylam sheet with min.3 mm thickness. 564 The panel drawing shall be approved before taking up the fabrication and compitable BMS if in future required. (ALL AHU PANEL WITH 565 In All panel Each starter should have remote control and interlocking facilities including auto manual switch, NO/NC contacts for control and must have auto manual operation suitable to take signal from fire alarm panel for automatic operation of fan in case of fire.All smoke /vent. fan panel the starters shall have suitable facility to operate with fire sensing control modules. 566 Vent. Fan Panel- MCC -1 567 Incoming 568 1 no. 63 amp MCCB 569 Phase indicating lights with control fuses. 570 Breaker ON/OFF/TRIP indicating lights. 571 Bus Bars 572 100 amp TPN Aluminum Bus Bar with heat shrinkable insulation colored sleeves. 573 Outgoings 574 3 nos. 6-10 A,TP MPCB(With DOL Starter) 575 The base frame shall be 75 mm x 5 mm. 576 Panel as described above and in drawings. 577 METER BOARD / SUB PANELS 578 Supplying, Installation, Testing and Commissioning of dust, damp and vermin proof free floor standing / wall mounted factory built sheet steel enclosed modular construction extendable panel, suitable for operation on 415 + 10% volts, 50 Hz AC 3 phase 4 wire system fabricated out of suitable sized square tubular section and covered with 2.0mm thick CRCA sheet, hinged doors of 2mm thick CRCA sheet, duly painted complete with aluminium bus bars, interconnection with solid copper conductor wires / aluminium strips, neutral links, earth bus etc. necessary metering protections & indications and mounted with the following as per drawing and technical specifications attached etc. complete as required. 579 ODUs Panel-01-TERRHVAC 580 Same as above item but outdoor Panel with following accessories. 581 INCOMING: 582 1 No. 200 amps, 415VTPN MCCB with overcurrent and short circuit releases, all indication, push button etc. 583 Coloured (Red, Yellow, Blue) phase indicating lamp - 1 set 584 (0 - 200 A) CT operated Ammeter with selector switch& 3 nos. CTs ratio 200/5A , 15VA burden & accuracy class of 1.0 - 1 set 585 0-500 V Voltmeter with selector switch - 1 set 586 BUSBAR: 587 250 Amp. TPN, 35 kA Al. Bus Bar 588 OUTGOINGS: 589 80A, TPN ELCB with 300mA- 3 Nos. (Incl. 1No. Spare) 590 40A, TPN ELCB with 300mA- 5 Nos. (Incl. 1No. Spare) 591 ODU Panel Described as above/As per Manufacturer ODU Configuration. 592 Spcl. Note : All Above mentionedpanel SITC as per actual GA dwgs. equipments and final config,. Of ODUs. 593 CABLING (POWER ) 594 Power Cabling and Earthing: 595 Spcl. All Cables Should be fire survival Cables (FRLS) 596 Supply, installation, testing & commisioning of LPCB approved mineral insulated copper conductor cables, construction as per BSEN 60702-1:2002 suitable for withstanding 950 deg under fire conditions as per BS 6387 CWZ and 850 deg under fire conditions on one single sample as per BSEN 50200. Cable should be manufactured with seamless copper tube and should be HFLS sheathed. (Tagging to be provided with aluminium strips on both the ends as approved). 597 3Cx10 Sqmm 598 3Cx06 Sqmm 599 3Cx04 Sqmm 600 4Cx06 Sqmm Cu 601 4Cx10 Sqmm Cu 602 Control Cabling 603 Supply, installation, testing & commisioning ofCopper conductor , PVC insulated, PVC sheathed armoured cable of 1.1 KV grade (Which is Interconnecting wiring for the fire alarm system with the AHU and the smoke dampers and AHU to Control Consol Panel). 604 8C x 1.5 Sqmm 605 Supply, installation, testing & commisioning of cable termination of above cables with copper lugs & flameproof brass compression glands on both the ends with inhibting compound etc. complete as required. 606 3Cx10 Sqmm 607 3Cx06 Sqmm 608 3Cx04 Sqmm 609 4Cx06 Sqmm Cu 610 4Cx10 Sqmm Cu 611 Supplying and installing following size of perforated G.I. cable trays, G.I. bends with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with suitable suspenders including G.I. bolts & nuts, painting of suspenders etc. complete as required. 612 100 mm. Width x 50mm. Depth x 1.6mm. Thickness. 613 150 mm. Width x 50mm. Depth x 1.6mm. Thickness. 614 225 mm. Width x 50mm. Depth x 1.6mm. Thickness. 615 Providing and fixing following size of G.I. strip / G.I. wire on surface or in recess for loop earthing alongwith the existing surface/ recessed conduit/ submain wiring / on cable tray/ on surface including G.I. clamps etc. complete as required. 616 6 SWG G.I. wire 617 Electrical work i.e. 618 3 Pin socket switch for Cassette, fcu, inline fan, propeller fan etc. near to the each unit. 619 Isolator Switch (Weather Proof) near to the each ODU. 620 Copper wiring /earthing from Isolator switch to M/C (chillers, pump, AHU , Fan etc.) 621 All DOL Starter Panel and Power cable for Fans/AHU 622 RCC Foundation for chiller, pumps, panels/outdoor units etc.. 623 Spcl. Note:The work includes design, supply, fabrication, erection, testing & commissioning of the complete air conditioning system with items specified above. 624 Supply Installation , Testing & Commissioning of 8 Passangers, 544 Kg. 1mps. Automatic Elevator, with VVVF and Microprocessor based Simplex Collective Selectivewith/without Provision ofattendant control. Separate Landing Push Button Box for all Landings with scrolling indicator. with provision of Attendant control, having 2 stops , 2 Openings with SS Cabin (Hair Line Finish) havingCross flow fan for Ventillation , having sleek (SS hair Line finish-PVC) and LED small Circular lighting all complete. 625 Other Features 626 Battery Operated Emergency Light And Alarm Bell 627 Call Register Signal And Vf Door Operator 628 False Ceiling In Car 629 Vandal Proof S.S. Button With S.S. Cover 630 Firemans Switch 631 Infra Red Door Screen 632 Full Car Operating Panel 633 3 Way Intercom / Press And Speak Phone 634 Push Button - Orange L E D Illumination 635 Dot Matrix Led D & P Indicators In Car & Landings -Orange Colour 636 Automatic Rescue Device 637 Minor Builders Work 638 Scaffolding 639 Floor Annunciator With Music 640 Braille Buttons 641 Sill Support 642 Lift License 643 Overload Warning Indicator With Audio Announcement 644 Pit Ladder 645 Auto Light & Fan Switch Off (Pod) 646 SUB HEAD - I: CIRCUIT CUM POINT WIRING 647 SWITCH CONTROL LIGHT POINTS 648 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 649 Group C 650 MCB CONTROL LIGHT POINTS 651 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. (Switch Control Primary Points) 652 Primary point controlled by one MCB. 653 Same as item above but Secondary point. i.e. Points to be looped with Primary pointwith 2.5 sqmm wire and Point wiring 654 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 655 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 656 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 657 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 658 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 659 2 x 10 sq. mm + 1 x 10 sq.mm earth wire 660 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 661 4 X 16 sq. mm + 2 X 6 sq. mm earth wire 662 Supplying and fixingsuitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing3 pin 5/6 Amp modular socket outlet and 5/6 A modular switch, connection etc. as required. 663 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 664 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 665 Telephone socket outlet 666 SUBHEAD -II - FITTINGS & FIXTURES 667 Supply, Installation, Testing and Commissioning of 18/20W Wall/Surface mouted 4 ft. LED 668 Supply, Installation, Testing and Commissioning of 40W LED POST TOP LANTERN 669 Supply, Installation, Testing and Commissioning of 40W LED GATE LIGHT 670 Supply, Installation, Testing and Commissioning of9W (Nominal)Wall Bracket Light 671 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 672 SUBHEAD - III - DISTRIBUTION BOARDS 673 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 674 12 way, Double door 675 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 676 Single Pole 677 Single Pole Neutral 678 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 679 40 A 680 63 A 681 Supplying and fixing following rating, double pole, (single phaseand neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 682 40 A 683 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Madhya Pradesh View Result →
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
46.
Power #9489488 Technical Bid
Overhauling Work Of Generator, Bus Duct And Its Auxiliaries Of 200Mw Unit No. 13 - Following works shall be carried out on Generator during O/H of unit no.13 2 O/H & preventive maintenance of 15.75KV bus duct inside T. G. Hall. 3 H2 Gas purging & recharging. 4 O/H work of Gen. P.T. cubicle protection metering & auxiliary PT cubical of R, Y, & B phases. 5 O/H work of earthing transformer & neutral grounding reactors: 6 Decoupling, removal, remounting alignment and coupling of AC/DC seal oil pumps 7 Attending leakage of oil from AC/DC seal oil pumps including replacement of seal if required. 8 Maintenance and greasing of bearings in A.C. seal oil pump. 9 Reconditioning of all 15.75kv bus duct perplex containers. 10 Monitoring and maintaining the level of hydraulic seal oil tank round the clock manually by opening and closing the adjacent valve after float valve (when required) from charging of Gen seal till completion of overhauling work. 11 Normalizing seal oil system and draining oil from Gen. casing and hydraulic seal oil tank round the clock (when required) from charging of Gen seal till completion of overhauling work. 12 Repair of cooling pipe circuit of mechanical seal of AC/DC Seal oil pump. 13 Fabrication and installation of ladder from 0m to 8m cable trench. 14 Repairing of fencing around earthing transformer and NGR. 15 Repairing of fencing around 15.75 bus duct excitation cable portion at zero meter near NGR. 16 Isolation and reconnection of 15.75KV bus duct outside T.G. Hall from manhole near A-Axis wall. 17 Preventive maintenance of slip ring carbon brushes, brush holder, neutral grounding transformer and reactor in 5x200MW units: 18 Bus Separation from Gen. Phases, Neutral 19 Work On Seal Oil/ Stator Water Cooler 20 H2 Gas Filling and Monitoring in Gen Casing 21 Changing excitation polarity 22 Removal and Remounting of Old PTs with new PTs of Generator 23 Replacement of Drainpipes of Hydrogen Gas cooler of Generator. 24 Repairing of oil pipeline of seal oil pump & associated works. 25 Arrangement for drain of expansion tank & associated works. 26 Replacement of Rubber Expansion bellows of phase/ neutral side of generator terminal. 27 Attending leakage in clarified cooling line/DM water line of stator water system 28 Replacement of gaskets from flanges and valves of various gas pipelines. 29 Miscellaneous works such as Welding and Fabrication jobs during Overhauling of unit 13 to be carried out as per site requirement. 30 Repairing Of leakage of 450mm pipeline. 31 Cleaning & Double coat painting work in Bus duct from general to a-axis of the turbine hall (phase & neutral side) with structure.( approx260 M2 ) 32 Cleaning & Double coat painting work in Neutral grounding transformer with reactor and fencing.(approx. 75 M2 ) 33 Cleaning & Double coat painting work in P. T. cubical box and its duct. (approx. 84 M2 ) 34 Cleaning & painting work of Generator Stator. (Approx. area 170 Sq.M.) 35 Painting and Cleaning work of Seal oil system (including Damper Tank, & all associated pipelines), expansion tank (including all associated pipelines), Gas system (including all associated pipelines), Excitation duct (Approx. area 400 Sq.M.)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 3
Uttar Pradesh View Result →
47.
Housing Urban and Rular Development #9488962 Technical Bid
Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeupto/aboveplinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 10 Foundations, footings, bases of columns, etc. for mass concrete. 11 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. 12 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 13 Columns,Pillars, Piers, Abutments, Posts and Struts. 14 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 15 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 16 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction Of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shall be as follows ; (1)Treatment for masonary & foundation 5 liters per/ 100 sqm. (2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters/100 sqm (5)Treatment Of soil along external perimeter of building 7.5 liters/100sqm. (6) Treatment Of soil under apron along external perimter 5 liters/100 sqm. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 20 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 23 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 24 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 28 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 29 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 30 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 31 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 32 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 35 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 37 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 38 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 39 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 40 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 41 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 42 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 43 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 44 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 45 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections 46 Cement plaster skirting up to 30 cm height,18 mm thick, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement. 47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 51 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 52 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm [IN FLOORING] 53 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete.Size of Tile 600x600 mm 54 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 58 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ .90 kg/ 10 sqm) 59 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 63 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 64 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 65 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 66 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 67 Coupler 110 mm 68 Bend 87.5° 110 mm bend 69 Shoe (Plain)110 mm Shoe 70 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 71 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 72 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 73 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 74 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 75 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 76 For vertical surface two coats @ 0.70 kg per sqm 77 For horizontal surface one coat @1.10 kg per sqm. 78 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 79 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 80 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 81 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum Water tank 82 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 83 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 84 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 85 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 86 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 87 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 88 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 89 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 90 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 91 Providing and fixing toilet paper holder :C.P. brass 92 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 93 90 mm O.D. 94 110 mm O.D. 95 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 96 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 97 90 mm size 98 110 mm size 99 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.BEND 87.5° 75 mm Shoe 100 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 101 90x90x90 mm size 102 110x110x110 mm size 103 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 104 90 mm size 105 110 mm size 106 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 107 90 mm size 108 110 mm size 109 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 110 90 mm size 111 110 mm size 112 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 113 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 114 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 115 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.cement and testing of joints complete as per direction of Engineer in charge Internal work - Exposed on wall 116 20 mm nominaldia pipes 117 25 mm nominaldia pipes 118 40 mm nominaldia pipes 119 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 120 15 mm nominal outer dia pipes 121 20 mm nominal outer dia pipes 122 25 mm nominal outer dia pipes 123 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 124 25mm dia, nominal bore 125 32 mm dia, nominal bore 126 40 mm dia, nominal bore 127 50 mm dia, nominal bore 128 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore 129 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 130 20 mm nominal bore 131 25 mm nominal bore 132 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 133 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 134 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 137 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 138 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : 139 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) 140 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg(weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 141 Extra for depth of man hole size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 142 Providing and fixing square mouthS. W. Gully trapSP 1 complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type 143 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 144 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 146 50mm nominal bore. 147 40mm nominal bore. 148 32mm nominal bore. 149 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 150 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 151 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 152 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 153 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 154 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 155 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 156 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 157 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 158 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 159 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 160 5/6 A switch 161 3 pin 5/6 A socket outlet 162 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 163 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 164 Supplying and fixing (75mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module ) 165 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 166 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 167 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 168 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 169 Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 170 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 171 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 172 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 173 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 174 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 175 4 way (4 + 12), Double door 176 6 way (4 + 18), Double door 177 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 178 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 179 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 180 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 181 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 182 40 A 183 63 A 184 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 185 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 188 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 189 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypePower Panel :Incoming -200 Amp MCCB - 1 No.Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No.(Complete as per requirment directed by Project Manager.) 190 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 191 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 192 Supply & fixing of IP 20, Mid Power SMD type LED1*1 square LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 193 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 194 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 195 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 196 size 6 sq mm x 2 core 197 size 70 sq mm x 3-1/2core 198 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 199 2 X 6 sq. mm (19mm) 200 3½ X 70 sq. mm (32mm) 201 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 202 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 203 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 204 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 205 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 206 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 207 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 208 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 209 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 210 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 211 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 212 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 213 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 214 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 215 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 216 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 217 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 218 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 219 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m HeadTerrace Pump 220 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 221 80 mm dia 222 100 mm dia 223 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 224 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 225 80 mm dia 226 100 mm dia 227 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 228 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 229 80 mm dia 230 100 mm dia 231 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 232 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 233 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 234 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 235 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 236 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 237 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 238 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 239 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 240 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 241 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 242 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 243 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 244 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 245 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 246 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 247 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 248 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 249 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 250 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -1 Set 251 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 252 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 253 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 254 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 255 Providing and fixing in position pre-moulded joint filleProviding and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charger in expansion joints. 256 Providing and filling in position rubberized bitumen hot sealingcompound for sealing of expansion joints in roads / pavementsall complete as per direction of the Engineer-in-Charge. 257 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 258 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 259 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 260 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 261 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 262 Providing & fixing 75mm dia vent pipes.Centrifugally cast (spun) iron socketed pipe asper IS: 3989 263 Providing & fixing of 75mm dia cast iron terminal guard.Sand cast iron S&S as per IS - 3989 264 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 500 mm internal diameter 265 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 266 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 300 mm dia all kinds of soil 267 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia 268 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 269 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm Nominal Size dia 270 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 271 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 272 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 273 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm Dia 274 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal size dia 275 Supply and Installation of 3.0 HP Submersible pump set complete 276 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia 277 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 278 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 279 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 280 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 281 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 282 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 283 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 284 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 285 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG/cm^2 286 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 287 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 288 Steel work welded in built up sections framed work,including cutting, hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .in grating ,frames,guard bar,ladder,railings,brackets,gates and similar works. 289 Supply and installation testing and commisioning of IP based EPBX system comprising of core switch & 1.2 switches 16 port EPBAX IP 4 trunk 290 Hand set IP 291 Master handset IP 292 Supplying and drawing of UTP 4 pair CAT 6 Lan cable 293 POE (Power over ethernet) 294 1 kva UPS 295 R1 4510 box with key stone 296 6U rack comrax (45x45x35 cm) DVR 297 PDU (Power distribution unit)) 298 Fan 299 Supply, Installation, Testing & Commissioning of Wireless indoor Access Point Combined data rate support Dual 5GHz 4.8 Gbps, 802.11ax, 2.4 GHz/5GHz: 4x4: 455 WiFi 6, data rate upto 2400 Mpbs. Four 2.4 GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omni Bluetooth Antenna, Transmit Beamforming and Maximal Ratio Combining the WLAN Access Point solution should have Integrtaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and honeypot Access Point detection, able to create WYLAN policies. The solution should be artifical intelligence based self healing soltion. Bluetooth®LE and toTsensor support Humidity pressure (Wi-Fi SYSTEM)Temperature, should also support Asset Tracking if required in future without any change in Hardware. 300 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 301 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping. The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class H or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables DG Set Compatible for synchronising Panel 35 KVA 302 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 35 sq mm x 3-1/2core 303 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 35 sq. mm (32mm) 304 Supply, Installation, Testing & Commissioning of Armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU G 652.D, G657A1, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly. Uni-Tube, Glass Yarn, Water Swellable Tape Under Armor UV-HDPE Jacket Approved Makes. Derwiser/Nexans Siemen Sistiman 305 Supply, Installation, Testing & Commissioning of 6 Port IU x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummer/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Thes, Panel shall be Powder Coated with Min 12mm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1, IEC-60754-1. Insertion loss <= 0 35 dB. Return Loss >= 50. Attenuation 1310/1550 10 3/0 2 dB/KM. Repeatability <= 02DB 1000 Tunes Mating Cycles, RoHS Complied. Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 306 Supply. Installation, Testing & Commissioning of 24 Port 10 x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummet Glands to close any open entry. Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices. Tube for open fibers. Ties, Panel shall be Powder Coated with Min | 2trm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1. IEC-60754-1, Insertion loss <= 0 35 dB, Return Loss >= 50. Attenuation 1310/1550 03/02 dB/KM. Repeatability <= 0 2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 307 Supply. Installation, Testing & Commissioning of fiber patch cord. LC-LC Spiral steel armored 9/125mm OS2 singlemode round cord (4.0 +/- 0.mm).Duplex approved makes Derwiser/Nexans/Stemon/Systimax 308 Supply. Installation, Testing & Commissioning of Cat 6A, 23 AWG (0 57.003mm) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tape or Metallic Shield inside. Connectivity of Hub room to End Point Approved Makkes Derviser/Nexans/Stemon/Systimax 309 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack. ISO/IEC 11801 2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C 2 Category 6A, IEC 60603-7 (603-7). Universal 110 Impact Tool & Tooless (Both) Termination, Min 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fi at user end Approved Makes Derwiser Nexans Siemon Systimax 310 Supply, Installation. Testing & Commissioning of loaded 24 port CAT 6A UTP. Transparent shutter ack panel, IU height, UL-94V-0, cicar label marks and earthing plug for CAT6A cable termination at rack end No Approved Makes Derwiser Nexans Siemon Systimax 311 Supply, Installation. Testing & Commissioning of Cat6A Putch Cord [TP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm. 1 Meter. Operating Temperature -20 to +60 Deg C Patch cord | Mtr for rack side swatch to jack panel connectivity Approved Makes. Derwiser/Nexans/Stemon/Systimax 312 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm, 3 Meter. Operating Temperature -20 to +60 Deg C Patch cord 2 Mtr for rack side switch to end user connectivity Approved Makes Derwiser Nexans/Siemon/Systimax 313 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone TypeShuttered Faceplates for 1/0 fixing at user side Approved Makes Derwiser/Nexans Stemon/Systimax 314 Supply, Installation, Testing & Commissioning of 42 U (600W/1000D) floor mount rack with fans, 2 cable managers, salationary shelf, 2 Nos of hardware pkts Approved Makes Derwiser MIS Rata/APC/APW 315 Supply, Installation, Testing & Commissioning of 22 U floor mount rack with fans. 2 cable managers satationary shelf. 2 Nos of hardware pkts Approved Makes Derwiser/MTS/Rital/APC/APW 316 Supply, Installation. Testing & Commissioning of 15t/ wall mount rack with fans, 2 cable managers. satationary shelf. 2 Nos of hardware pkts Approved Makes Der Wiser/MIS/Rittal/APC/APW 317 Supply, Installation, Testing & Commissioning of Core Switch with switching capacity of 12 Tbps, forwarding performance of 1000 Mpps with 24x 1/10G SFP+ ports expandable to 40 SFP+ ports with 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, Stacking/Virtual Chasis support upto 9 Switches with bandwidth 140 Gbps, 64K IPv4 and IPv6 Routes and 30K multicast routes MAC Address 250K, Jumbo frame 9000 bytes should support Routing protocols (KIPng OSPF v3, IS-IS v6, BGPv6) with 1 year support Should be Common Criteria/NDPP/NDCPP certified & IPv6 Logo Certified OEM should be Leader in Forrestor SDN & Gartner Data Centre latest report Approved make - Cisco / Juniper / Impulse / Nexxus/Arista 318 Supply, Installation, Testing & Commissioning of 12 Port POE+ Access Switches with switching capaticy of 200 Gbps, forwarding performance 150 Mpps, having 24 x 10/100/1000BASE-1 Pol-plus(RJ45) with minimum PoE budget of 370 W, with 4 x 10G SFP+ uplink ports Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address Should have Static Routing. Neighbor discovery, system logging. Telnet, SSII, SNMP, Network Tune Protocol (NTP), Domain Name System (DNS) and IPv6 features from day I and should support OSIF, VRRP, OSPFv3 and PIM Approved make - Cisco/Juniper / Impulse/Nexxus/Arista 319 Supply, Installation. Testing & Commissioning of fiber Modules 10G BASE Approved Make Cisco/Juniper / Impulse/Nexxus/Ariste 320 Supply. Installation, Testing & Commissioning of Wireless Indoor Access Point Combined data rate support Dual SGHz 4.8Gbps, 8021lax, 24 GHz/5GHz 4x4 4SS WiFi 6, data rate upto 2400 Mpbs. Four 2.4GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omn: Bluetooth Antenna Transmit Beamforming and Maxımal Ratio Combining the WLAN Access Point solution should have integriaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and 1 honeypot Access Point detection, able to create WxLAN policies The solution should be artifical intelligence based self healing soltion Bluetooth LE and loTsensor support Humidity Pressure Temperature, should also support Asset Tracking if required in future without any change in Hardware Omni-directional Bluetooth Antenna, superbeacon mode with iBeacon and Eddystone, OFDMA & BSS Coloring support Operating temp 0 to 40 degree. Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse/Nexxus/Arista 321 Supplying Installation Testing & Commissioning of Wifi & Dual Band Ax 1800 (WAVE2, MU MIMO, 802 11AX (2x2)) with 2 5 Gbps Poe+ Port Mesh Access Point as required at site. Approved Make Cisco/Juniper / Impulse/Nexxus/Arista/Netgear 322 Supply. Installation, Testing & Commissioning of Wireless Controller Should be Artificial Intelligence (AI) driven Microservices based architecture. The Solution should support 802.11ac primarily and should be backward compatible to 802 | In/a/b/g The solution should also support 802 | lax with Guest Portal support, support WIPS, Rouge AP detection and Honeypot AP detection, able to provide insights based on Time to connect, successful connect, coverage, capacity, AP Uptime, Roaming and throughput able to integrate with varous authentication mechanism including the RADIUS servers, able to handle interference and shift the communication on another channel automatically if, needed, support Dynamic Packet capture to enhance troubleshooting Microservice based Architecture should be scalable to handle around 5000 APs or more in future, Should have a virtual assistant to troubleshoot deeper and facilitate investigation of existing or future issues in the Wi-Fi network Artificial Intelligence feature should be manageble from Wireless to Switching devices Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse / Nexxus/Arista 323 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 324 ANGLE IRON90*90*6 mm 325 T-SECTION 90*90*6 326 HOLD FAST40*6 FLAT 327 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. G.I. Pipe(80 MM DIA)
Contract Date: Ref. Documents Contract Value : Ref. Document
Boards / Undertakings / PSU No of Bidders 2
Uttar Pradesh View Result →
48.
Housing Urban and Rular Development #9481110 Technical Bid
Construction Of Main Location For T.F.C. Ram Van Gaman At District Chitrakoot (U.P.) - TFC, RAMVANGAMAN 3 Carriage of good earth by mechanical transport including loading, unloading and stacking 4 (upto 20KM) 5 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 6 All kinds of soil 7 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 8 All kinds of soil (From 1.5 to 3 m depth) 9 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 10 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 11 Supplying chemical emulsion in sealed containers including delivery as specified. 12 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 13 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : 14 Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : 15 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 16 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 17 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 18 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 19 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 20 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 21 Centring and shuttering including strutting,propping etc. and removal of form for 22 Foundations, footings, bases of columns etc. for mass concrete. 23 Suspended floors, roots, landings, balcnies and access platform. 24 Shelves (Cost in situ) 25 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 26 Columns,Pillars, Piers, Abutments, Posts and Struts 27 Stairs, (excluding landings) except spiral-staircases 28 Edges of slabs and breaks in floors and walls Under 20 cm wide 29 Weather shade, Chajjas, corbels etc., including edges 30 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured)Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 31 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 32 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 33 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 34 All works upto plinth level 35 Concrete of M30 grade with minimum cement content of 350 kg /cum 36 All works above plinth level upto floor V level 37 Concrete of M30 grade with minimum cement content of 350 kg /cum 38 Add for using extra cement in the items of design mix over and above the specified cement content therein. 39 ANCHOR BLOCK FOR STONE BENCHES 40 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 41 400 mm dia piles 42 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 43 400 mm dia piles 44 Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. 45 Single pile upto 50 tonne Safe capacity 46 Initial test (Test Load 2.5 times the Safe capacity) 47 Routine test (Test Load 1.5 times the Safe capacity) 48 MASONRY WORK 49 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 50 Cement mortar 1:6 (1 cement : 6 coarse sand) 51 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 52 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 53 WOOD WORK 54 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 55 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 56 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 57 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 58 Rectangular or square. 59 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 60 1.0 mm thick 61 Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. 62 With 12 mm mild steel U beading 63 Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). 64 Providing and fixing 12 mm thick frameless toughened glass partitions of approved brand and manufacturer, including providing and fixing partitions at top & bottom with aluminum channel etc. all complete as per direction of Engineer-in-charge 65 Providing and fixing approved brand and manufacturer SS 304 grade hardwares for Doorsetc. 66 Providing and fixing approved brand and manufacture SS 304 grade D type 300mm Pull Handle with 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 67 Providing and fixing approved brand and manufacture SS 304 grade Glass door Lock, top and bottom patch fitting with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 68 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 69 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 70 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 71 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 150mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 72 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 73 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 74 Providing and fixing 85x42 mm chromium plated brass pull bolt lock with necessary chromiumplated brass screws, nuts, bolts and washers etc. complete. 75 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 76 125 mm 77 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 78 Toilet CubicalProviding and fixing Toilet Cubicle (of following standard dimension which includes 600 mm door size width) made of heat, bacteria, water, chemical, scratch, impact and anti bacterial resistant 12 mm thick solid compact laminate panelsFinish of the compact laminate should be raw silk which include doors, pilasters and intermediate panels finished with approved texture/shade as per the detail drawing and as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97 standard.This also includes providing and fixing in position necessary hardware made out of Stainless Steel (Grade 316) as per manufacturers specifications and EIC instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset indicators, (4) Coat hooks, (5) U- Channels, (6) SS-Shoe Box Plate, (7) MS-Base Plate, (8) Rubber noise deafening tape, (9) Screws and wall Plugs. 79 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. 80 Using M.S. angels 40x40x6 mm for diagonal braces 81 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 82 Hot finished welded type tubes 83 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 84 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 85 Providing and fixing stainless steel (Grade 316) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 86 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 87 25 mm thick 88 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 89 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. 90 Glazed Vitrified tiles Matt/Antiskid finish of size 91 Size of Tile 600 x 600 mm 92 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. 93 Size of Tile 600 x 600 mm 94 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 95 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 96 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. 97 Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent 98 Extra for pre finished nosing to treads of steps of Granite stone. 99 Extra for Granite stone flooring in treads of steps and risers using single length up to 2.00 metre . 100 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : 101 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 102 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. 103 Granite of any colour and shade 104 Area of Slab over 0.50sqm 105 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 106 Granite work. 107 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 108 Extra for providing opening of required size & shape for wash basins/ kitchen sink in kitchen platform, vanity counters and similar location in marble/Granite/stone work including necessary holes for pillar taps etc. including rubbing and polishing of cut edges etc. complete. 109 12mm cement plaster of mix : 110 1:6 (1 cement: 6 coarse sand) 111 15 mm cement plaster on the rough side of single or half brick wall of mix : 112 1:6 (1 cement: 6 coarse sand) 113 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 114 6 mm cement plaster of mix : 115 1:3 (1 cement : 3 fine sand) 116 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 117 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 118 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 119 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 120 Two or more coats on new work including priming coat of ordinary paint approved brand. 121 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 122 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 123 Stone work ashlar sunk or moulded or sunk and moulded upto floor five level in cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : 124 White sand stone 125 Extra for stone work ashlar sunk or moulded or sunk and moulded or carved in : 126 Triangular or Square or rectangular pillars 127 Circular or polygonal pillars 128 Extra for stone work ashlar sunk or moulded in cornices. 129 Stone work, plain in copings, cornices, string courses and plinth courses, upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. 130 White sand stone 131 DRY CLADDINGProviding and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 132 White sand stone - 30mm thick gang saw cut stone 133 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 134 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 135 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 136 Providing and fixing stone jali 40 mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc. 137 White sand stone 138 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 139 12.5 mm thick tapered edge gypsum moisture resistant board 140 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 141 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 142 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 143 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65mm. 144 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours.(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. 145 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 146 In 75x75 mm deep chase 147 Providing and laying broken AAC Block in sunken portion of W.C. & kitchen. These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge. 148 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 149 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : 150 For fixed portion 151 Powder coated aluminium (minimum thickness of powder coating 50 micron) 152 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 153 Powder coated aluminium (minimum thickness of powder coating 50 micron) 154 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 155 PLUMBING Work 156 SANITARY INSTALLATIONS 157 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. 158 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. 159 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 160 White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 161 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- 162 White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer 163 Providing and fixing Stainless Steel AISI 304 (18/8) kitchen sink of approved makeas per IS: 13983 with C.I. brackets and stainless steel plug 40 mm, including painting offittings and brackets,cuttingandmakinggoodthe walls wherever required 164 Kitchen sink with drain board 165 510x1040 mm bowl depth 250 mm 166 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. 167 Providing and fixing Differecially abled toilets including Wash basin, Water closet,Cistern, grab bars & hand rails etc. The rate include cost of all material & labour involved in the item complete and all as per direction of engineer incharge.For physically handicap person consisting of; 168 Providing & fixing heavy quality PVC waste pipe for sink including PVC waste fitting Complete 169 Flexible Pipe 170 40mm Dia 171 Providing & fixing toilet paper holder 172 C.P. brass 173 Providing, fixing, jointing and testing in position of ISI marked UV stabilized UPVC pipesfor soil, waste SWR Type-B as per IS : 13592 suitable for rubber ring joints for vertical pipes and solvent cement joints for horizontal pipes, including all neccessary specials and fittings (confirming to IS:14735) i.e. bends, tees, junctions (with or without doors),reducers, couplers, cowels, clamps, hangers, rubber rings, clean outs, provision for C P Grating fixing for any waste connection from washing machine etc. fixing at wall / ceiling / floor level supported by clamp & hangers etc.inside duct / suspended from floor under false ceilingfor proper completion of the work. The rubber ring shall confirm to IS:5382. ( (SOIL, WASTE, RAIN WATER & VENT) 174 110 mm diameter pipe 175 Providingandfixingin position Upvc full bore P / S trap with 50 mm water seal(IS : 14735) of the following sizes .Making proper connection with solvent cement. 176 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg/cm2) including injection moulded fittings, jointing with solvent cement, cutting and making good the floors and walls and jointingto trap/waste pipe, complete of outer dia. (Indirect waste) 177 40mm diameter pipe 178 50 mm diameter pipe 179 63 mm diameter pipe 180 Providing & fixing Nickel Chromium Platedliquid soap dispenser with metallic bottle of approved brand & make112 mm distance from wall of standard shape with bracket (Nickel chromium plating should pass Salt Spray Test for 200 hours) of the same materials with snap fittings of approved quality and colour, complete as per direction of Engineer in Charge. 181 Providing & fixing soap dish holder of approved design. 182 Providing and fixing CP brass single lever low flowwall mounted Sink mixer with 15 mm CP brass single lever swivel spout with waste complete with flow rate 2.5 litre per minute at 3 bar including cutting and making good the walls where required. 183 Providing and fixing of approved make following-a) Concelaed type CP Brass diverter(for hot and cold water), overhead shower with arm with rubit cleaning system with flow rate 6 litre per minute at 3 bar complete with all accessories as requiredand spoutwith flow rate 3.8 litre per minute at 3 bar, wall flange complete with all accessories as required and making good the walls wherever required. 184 Providing,Fixing wall mounted of approved make Double Coat hookon door complete. 185 Providingand fixing CP brass 2 Way Bib cock with wall flange with flow restrictor with flow rate 2.5 litre per minute at 3 bar. 186 Providing, fixing, testing & commissioning of Floor drain made of uPVC reducing elbow (110x63 mm) with horizontal drain outlet of 63 mm OD, round top of 110 mm OD. (Floor Drain) 187 Providing & fixing uPVC clean out plug with suitable opening with threaded uPVC socket fixed to uPVC pipe joints as required complete in all respects. 188 110 mm dia 189 Providing, fixing and testing of uPVC SWR inlet fittings with two or three saddle inlets of 40, 50 or 63 mm size, fabricated from 110 mm outer dia uPVC pipes and fixed to uPVC traps with solvent cement joint complete in all respect. 190 Providing and fixing SS Grating of 125 mm dia of approved quality and colour complete as per direction of engineer in charge. 191 Circular Type 192 125 mm nominal dia with 25 mm waste hole 193 Providing, Installing & fixing storage type water heater of approved make (vertical/horizontal type ) with copper container, glasswool insulation,stove enamelled M.S jacket, thermostatically controlled inner heater with pilot neon lamps, 15mm inlet stop cock valve, on inlet connection, 15mm dia C.P flexible connection pipe in inlet & outlet suitable for working pressure of 8 kg/sqcm complete as required. 194 Capacity 25 litres 195 Capacity 40 litres 196 Capacity 06 Litres 197 WATER SUPPLY 198 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. 199 Concealed work, including cutting chases and making good the walls etc. 200 15 mm nominal outer dia Pipes 201 20 mm nominal outer dia Pipes 202 25 mm nominal outer dia Pipes 203 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 204 Internal work - Exposed on Wall 205 20 mm nominal outer dia Pipes 206 25 mm nominal outer dia Pipes 207 32 mm nominal outer dia Pipes 208 40 mm nominal outer dia Pipes 209 50 mm nominal outer dia Pipes 210 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 211 External Work 212 50 mm nominal outer dia Pipes 213 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 214 20mm nominal bore 215 25mm nominal bore 216 32mm nominal bore 217 40mm nominal bore 218 50mm nominal bore 219 65mm nominal bore 220 Providing and fixing uplasticised PVC connection pipe with brass unions : 221 45 cm length 15 mm nominal bore 222 Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : 223 With common burnt clay F.P.S (non modular) bricks of class designation 7.5 224 Providing and filling sand of grading zone V or coarser grade, allround the G.I. pipes in external work : 225 65 mm diameter pipe 226 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 227 15mm nominal bore 228 Providingand fixingC.P. brass angle valve for basin mixture and geyser points of approvedqualityconfirming to IS: 8931. 229 Providing and fixing enclosed type water meter (bulk type) conforming to IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber insertions etc. (The tail pieces if required will be paid separately) : 230 100 mm dia nominal bore 231 Providing, fixing, testing & commissioning of level operated water type butterfly valve conforming to IS : 13095/BS 5155 having CI iron body , ss 316 grade dick, EPDM / nitride complete with 2 Nos. matching flanges, rubber insertion, nuts, bolts and washer etc. of following sizes with locking arrangement. 232 Pressure Rating PN 25 : 233 80 mm dia. 234 Non - return valve with dual plate of CI Body SS plates vulcanized NBR seal flanged end & PN 25 rating as specified. 235 65mm dia. 236 Providing & fixing CI `Y Strainer (screwed/ flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange/ unions nuts, bolts and washers complete as required. 237 80mm nominal bore 238 Supplying and fixing in position of approved quality Solenoid Valve with by-pass arrangement, isolation cock etc. complete with all required accessories such as level sensor, level indicator, level controller and required cabling for the same. 239 50 mm dia 240 Providing, Installing and Giving satisfactory field testing of Static (Ultrasonic) Domestic Battery operated, MID (Measuring Instrument Directives) approved Static AMR Water Meters diameters having no moving/fixed part in contact with water, with fully body made up of composite material, confirming to ISO 4064 along with manufacturing test certificate and Guarantee certificate with Meter & Battery Guaranteed up-to 10 years with RF Technology for communication. Memory of the device should be directly accessible through an optical scanner. 241 50 mm dia 242 DRAINAGE 243 Providing, laying and joining in position HDPE DWC (Double Wall Corrugated)and conforming to I.S. 16098 of required grade SN-4/SN-8 and suitable for the respective working pressures with all fittings and specials, e.g. couplings, tees, bends, reducers, screwed adapters, flanged tail pieces, etc., jointing as per manufacturers recommendations, all complete including trenching, backfilling & pressure testing etc. (For Sewer & Storm water line). 244 200 mm dia (SN-4) 245 250 mm dia (SN-4) 246 250 mm dia (SN-8) 247 300 mm dia (SN-8) 248 400 mm dia (SN-8) 249 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round HDPE pipes/ RCC pies/S.W. pipesincluding bed concrete as per standard design: 250 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 251 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of HDPE pipes/ RCC pies/S.W. pipes including bed concrete as per standard design : 252 200 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 253 300 mm diameter HDPE pipe/ RCC pipe / S. W. pipe 254 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 255 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 256 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 257 300mm dia RCC pipe 258 450mm dia RCC pipe 259 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90 x 80 cm and 45 cm deep including CI cover with frame (light duty) 455 x 610mm internal dimensiions total weight of cover and frame to be not less than 38 Kg. ( weight of cover 23 Kg. and weight of frame 15 Kg.), with FPS bricks with class designation 7.5With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 260 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : 261 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 262 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 263 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 264 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12mm thick cement plaster at the external surface shall be paid for separately): 265 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 266 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 267 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mmx25mm and over all minimum length 263 mm and width as 165mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 268 Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality 269 HD - 20 270 Circular shape 560 mm internal diameter 271 Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : 272 For pipes 100 to 250 mm diameter 273 For pipes 350 to 450 mm diameter 274 Constructing brick masonry road gully chamber 50x45x60cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450mm precast RCC horizontal grating with frame complete as per standard design. 275 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 276 EARTH WORK, CONCRETE WORK 277 Excavating trenches by mechanical / manual means of required width for pipe, cables etc including excavation for sockets ,& dressing of sides ,ramming of bottoms ,for all depth including getting out the excavated soil,& then returningthe soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming ,watering, etc and disposingof surplus excavated soil as directed, within lead of 50m. 278 All kinds of soil 279 Pipes, cables etc exceeding 80 mm dia but not exceeding 300 mm dia 280 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 281 Excavating trenches of required width for pipes, cables, etc including excavation for sockets,depth upto 1.5 m, including getting out the excavated matterials, returning the soil as requred in layers not exceeding 20 cm in depth including consolidating each deposited layers by by ramming, watering,etc. and stacking serviceable material for measurements and disposal of unserviceable matterial for measurement and disposal of unserviceable matterial as directed within a lead of 50m: 282 Ordinary rock 283 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 284 Hard rock (requiring blasting) 285 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 286 Earth Work in excavation by mechanical means (Hydraulic / excavator ) manual means over area (exceeding 30 cm in depth ,1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50m and lift upto 1.5m, as directed as engineer incharge. 287 Ordinary Rock 288 Hard Rock(requiring blasting) 289 TUBE WELL BORING WITH PUMP 290 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge, upto 90 metre depth below ground level. 291 400 mm dia 292 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 293 400 mm dia 294 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.ection of Engineer -in-charge. 295 200 mm nominal size dia 296 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 297 200 mm nominal size dia 298 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 299 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by V notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. 300 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 301 200 mm dia 302 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp. 303 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia. 304 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 65 mm dia nominal bore 305 Sypply and Installation of 800 LPM Submersible Pump Set of 10 H.P. capacity, K.S.B. Make including Starter panel, support wire, A. Meter etc. complete. 306 Supply and fixing of nylon jali around the slotted pipes complete as required. up to 10 meter 307 Sypply and laying of alluminium conductor pvc insulated armoured served sheathed cables 1100 volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt brick on sides and on top. On surface the cable run shall be fixed on m.s clamps etc. of suitable size or as directed by the Engineer in charge , complete in all respect . the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 308 35 SQ.MM 3-1/2 core 309 Water testing chemical and bactriological 310 RAIN WATER HARVESTING 311 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. 312 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil 313 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) 314 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) 315 Centering and shuttering including strutting, propping etc. and removal of form for : Suspended floors, roofs, landings, balconies and access platform 316 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation-7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 317 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 318 15 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand) in single coat on rough side of single or half brick wall. 319 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square bar 320 Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg 321 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 322 All types of soil 323 400 mm dia 324 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 325 200 mm nominal size dia 326 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 327 200 mm nominal size dia 328 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 329 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 330 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 331 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineerin- charge. 332 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 333 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia 334 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 200 mm dia 335 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m: 336 All kinds of soil 337 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 338 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : 339 150 mm dia. R.C.C. pipe 340 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round P.V.C. pipes including bed concrete as per standard design: 341 150 mm diameter P.V.C. pipe 342 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 343 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 344 FIRE FIGHTING WORKS 345 Supply, installing, testing and commissioning of clear water packagedFire Fighting Pumping System - to be placed near water tank on Terrace ( fixed speed type) as per following details: 346 Supplying,Installation,testing & commissioning of dust & vermin proofdouble door with canopy type taperd roof wall / floor mounted compartmentlised feeder piller type cubical control Panel for fire fighting terrace pump of front area not less than 1.0 Sqmtr. and depth not less than 300 mm, made out of 2mm thick CRCAsheet with 100 Amp. 4 strip aluminium bus bars with front openable door & locking arrangement, interconnection, control wiring, intrigation with pressure switch i/c suppying & fixing following switchgears & control gears/starters etc. as required.Incomming63 Amps. TP & N SFC with HRC fuses Voltmeter (0-500 Volt) with selector switch.Ammeter (0-60 Amps.) with selector switch & CTs.Set of 3 phase indication lampSuitable HP fully automatic Star/Delta Starter with over load protection, current sensing type single phase preventor complete with all accessories and internal wiring required for automatic operation.Selector switch for local/remote, auto/manual/off operation ON/OFF indication etc. 347 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. It should be complete as per specifications & directions of Engineer-in-charge. 348 3 X 10 sq. mm (22mm) 349 Supplying & laying one number XLPE insulated PVC sheathed Aluminium Conductor armoured UG cable of1.1 KV grade Conforming to IS 7098/1988 with upto date ammendment of following size in the existing RCC/HUME/ METAL /GI /CI /Stoneware/DWC pipe/masonary Open Duct/ cable tray/ open in air etc. as requred. 350 3 core,10 sq.mm. Aluminium Armoured 351 Providing laying, testing & commissioning of C class heavy duty MS Pipe conforming to IS 1239/3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. in ground including welding, excavation & providing cement concrete blocks as supports, anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of following sizes complete as required. ( For Underground ) 352 100 mm. Dia 353 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required.(Plant Room piping/Vertical Riser/Downcomer/Floor) 354 25 mm dia 355 32 mm dia 356 40 mm dia 357 50 mm dia 358 65 mm dia 359 80 mm dia 360 100 mm dia 361 Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required : 362 Single headed Gunmetal 363 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required : 364 Single headed Gunmetal 365 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 366 100 mm dia 367 Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 368 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 369 100 mm dia 370 Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. 371 100 mm dia 372 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : 373 Gun Metal 374 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 1258520 mm nominal internal dia gun metal globe valve & nozzle.Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.36 m 375 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required : 376 Gun metal 377 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 378 2 way-100 mm dia M.S. Pipe. 379 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 380 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories : 381 Upright Sprinkler 382 Providing & fixing flow switch in following sizes M.S. pipe including connection etc as required. 383 100mm dia 384 Providing, fixing, testing & commissioning of installation control valve of cast iron body, brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required 385 100mm dia 386 Supply, fixing, testing and commissioning of screwed type brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 & spindle AISI 410) with setting & gland of superior quality having minimum working pressure of 16 kg/sqcm. 387 25 mm Dia 388 Providing and fixing 25 mm dia inspection & testing assembly with gun metal ball valve, gun metal sight glass ,Reducer ,union, G.I PIPE. connection to drain pipe/riser. 389 Providing and fixing in position the industrial type pressure gauges with gun metal / brass valves complete as required 390 Providing and fixing standard firemans axe with heavy insulated rubber handle conforming to IS: 926 complete. 391 Providing & Fixing of MS door made up of 16 gauge MS Sheet capable of accommodating fire hose reel, landing valve, hose pipes, fittings, 1 No. CO2& 1 No. Dry podwer type portable fire extinguishers & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with one coat of primer & two coat of finished stove enamelled post office red colour paint & FIRE HOSE written on front. (Approx. size of door: 2100 mm HEIGHT, WIDTH OF DOOR AS PER SHAFT SIZE ) 392 Providing and fixing hose cabinet of size 750mmX600X250mm made of 16 gause thick MS sheet with 4 mm thick float glass doors in front painted FIRE in red paint i/c recessary locking arrangement suitable to accommodate external hydrant with butterfly valve 2 nos. 15 mtr. long hose pipe. 1 no. brach pipe mounted on wall or raised brick platform & duly painted with post office red externally and white internally with synthetic enamel paint complete in all respects for external hydrant. as directed by Engineer-in-Charge. 393 Providing, Fixing, testing and commissioning of resilient rubber lined single arch vibration eliminators suitable for raw water up to 45 deg. C temperature, working pressure 11 Kg/cm2 and test pressure 16 Kg/cm2 to provide relief from stresses at pipe flanges. 394 80 mm dia 395 Supply and fixing of 4 Nos G.I round bottom FIREBUCKETof 9 LTR. Capacity field with stand including proper supporting /mounting arrangement MS Angle Iron Frame painted by fire red colour over 2 coats of red oxide paint and written with white paint FIREcomplete in all respects as per direction of Engineer Incharge . 396 Providing, storing, handling, shifting, installation, testing and commissioning of halon free portable fire Extinguishers as described below: 397 Concealed work, including cutting chases and making good the walls etc. 398 Providing and fixing of 4.5 Kg. carbon-di-oxide type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase ingernal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming ro IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with internal charge. 399 Providing and fixing 6.0 Kg. ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guase internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished externally with re enamel paint and fixed to wall with brackets complete with inernal charge. 400 Providing, fixing, testing and commissioning of 50 Litres (trolley mounted) Mechanical Foam type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket / trolley mounted and confoming to IS:13386 . 401 Providing, fixing, testing and commissioning of CO2 type Fire Extinguisher of capacity 22.5 kg filled with Co2 Gas as per IS 15222 with controll discharge mechanism fitted with Hose, Horn & TROLLEYconfirms to IS 2878 bearing ISI mark. Co2 Cylinder as per IS 7285. 402 Providing and fixing 2 kg capacity clean agent-HFC 236FA Stored Pressure type fire extinguisher ISI marked under IS:15683 complete with importedNovec 1230 manufactured by 3M, with Zero Ozone Depeltion Potential and Very Low Global Warming Potential of 1 with 20 Years Blue Sky Warantee against any regulatory Bans and Restrictions. 403 ELECTRICAL WORK 404 WIRING 405 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 406 Group C 407 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 408 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steelconduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. 409 Group C 410 Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 411 1 or 2 Module (75mm×75mm) 412 3 Module (100mm×75mm) 413 4 Module (125mm×75mm) 414 6 Module (200mm×75mm) 415 8 Module (125mm×125mm) 416 12 Module (200mm×150mm) 417 Supplying and fixing following modular switch / socket on existing modular plate and switch box including connections but excluding modular plate etc as required. 418 5/6 amps switch 419 2 way 5/6 amps switch 420 15/16 amp switch 421 3 pin 5/6 amp socket outlet 422 6 pin 15/16 amp socket outlet 423 Telephone socket outlet 424 TV antenna socket outlet 425 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 426 2 x 1.5 sq.mm. + 1 x 1.5 sq.mm. earth wire. 427 2 x 2.5 sq.mm. + 1 x 2.5 sq.mm. earth wire. 428 2 x 4 sq.mm. + 1 x 4 sq.mm. earth wire 429 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 430 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 431 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 432 Installation of exhaust fan in the existing opening , including making good the damage, connection, testingcommissioning etc. as required. 433 (a): Up to 450mm sweep 434 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 435 Extra for fixing the louvers / shutters complete with frame for a exhaust fan of all sizes. 436 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required. 437 Installation, testing and commissioning of ceiling fan,including wiring the down rods of standard length (upto 30 cm) with 1.5sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 438 Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. 439 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 440 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 441 20 mm 442 25 mm 443 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 444 20 mm 445 25 mm 446 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 447 Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required 448 Supplying and fixing Data Socket Outlet including modular base and cover plate and 1.6mm thick GI Box etc, complete as required with all acessories and upto the satisfaction of engineer-in-charge. 449 Supply, Installation, Testing & Commissioning of LSZH Cat 6 unshielded twisted pair computer cable with 23 AWG solid copper conductors in existing concealed / surface conduits / Raceways, complete as required and as per technical specifications. (for DATA & Voice outlets) (From ONT box / Rack to Outlets). 450 DISTRIBUTION BOARD 451 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB / Isolator). 452 8 way , Double door 453 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as r.equired. (But without MCB/RCCB/Isolator). 454 6 way (4 + 18), Double door 455 8 way (4 + 24), Double door 456 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally usedwhere 3 phase outlets are required.) 457 12 way (4 + 36), Double door 458 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. 459 For 8 way, Double door SPN MCBDB 460 Supplying and fixing Cable End Box (Loose wire box) suitable for triple pole and neutral, sheet steel, Vertical MCB distribution board, 415 V, on surface/ recess, complete with testing and commissioning etc. as required. 461 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 462 Single pole 463 Supplyingand fixingsingle pole, blanking plate in the existing MCB DB complete etc. as required 464 Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 465 25 A 466 40 A 467 63 A 468 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 469 12 way (4 + 36), Double door 470 Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and 471 For 8 way, Double door FP MCBDB 472 Supplying and fixing of following MCBs, 415 volts, C curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 473 25A 4P MCB 474 40A 4P MCB 475 63A 4P MCB 476 EARTHING 477 Earthing System 478 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 479 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required. 480 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 481 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 482 Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. 483 LT CABLES & TERMINATIONS 484 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 485 Above 35 sq. mm and upto 95 sq. mm 486 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on cable tray as required. 487 Upto 35 sq. mm (clamped with 1mm thick saddle) 488 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 489 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. 490 4 X 25 sq. mm (28 mm) 491 3½×70 sq.mm (38mm) 492 Supplying, unloading, storing of following sizes of 1.1 kV grade XLPE insulated, FRLS outer sheath (Heavy duty) Aluminium/copper conductor, armoured/unarmored cables as per mentioned code, suitable for working voltage upto and including 1100 Volts,to be laid and tied on existing overhead cable trays; or buried underground or laid and tiedover MS supports in masonry trenches alongwith the test report of following sizes of cable to be submitted by the contractor at the time of delivery of material at site. 493 3.5C X 70 Sqmm Al. Armd. 494 4C X 25 Sqmm Al. Armd. 495 4C X 6 Sqmm Cu. Armd. 496 3C X 6 Sqmm Cu. Armd. 497 1C X 6 Sqmm Flexible wire including termination 498 Supplying following 1.1kV grade, XLPE insulated, FRLS type control cables,suitable for 415V, 50Hz, AC system, with inner and outer PVC sheath, outer sheath provided with FRLS insulation and with all components as mentioned in BOQ, specifications and schedule, complete as required. 499 4C X 2.5 sqmm copper conductor 500 6C X 2.5 sqmm copper conductor 501 Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 kV grade as required. 502 4C X 6 Sqmm Cu. Armd. 503 3C X 6 Sqmm Cu. Armd. 504 CABLES MANAGEMENT 505 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 506 100 mm width x 50 mm depth x 1.6 mm thickness 507 150 mm width x 50 mm depth x 1.6 mm thickness 508 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray bends (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 509 100 mm width X 50 mm depth X 1.6 mm thickness 510 150 mm width X 50 mm depth X 1.6 mm thickness 511 Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray Tee (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 512 100 mm width X 50 mm depth X 1.6 mm thickness 513 150 mm width X 50 mm depth X 1.6 mm thickness 514 LIGHTING FIXTURES & FANS 515 The CRI of the fixtures used in should be minimum 90. LED binning < 3-Step MacAdam UGR<19All fixtures shall be with prismatic diffuser. All light fixtures shall be LED having LM79 and LM80 certification from NABL accreditedlaboratory and relevant approved IES files for Dialux. Before dispatch of approved light fixtures,third party test shall be carried out by NABL accredited lab and the test reports shall be submitted.The Service Life of the fixture including driver/control gear should be minimum 50,000 burning hours. The THD should be less than 10%.The housing of the indoor fixtures should be extruded aluminium/CRCA.The IP category should be IP20 or higher for indoor applications and IP65 or higher for outdoorapplications. The Surge Protection to be provided conforming to relevant IS standards/IEC 61643-II Class-2 &EN 61643-II Type-2. The manufacturer’s name/logo should be engraved/embossed on the housing/body or Name/Logo onaluminium plate labels or Name/logo printed on housing/body. The warranty period on complete luminaire including driver/control gear, LED, all accessories should be 5 years from the actual date of completion of work. The Power factor should be 0.95 or higher.All light fixtures (internal/external) and drivers shall be BIS certified. The manufacturer shall submitBIS certificates with respective R codes for each fitting and driver for approval before execution. Number of fittings shall be provided on the basis of average illumination range for different areasmentioned below subject to maximum LPD specified in CPWD internal specification 2013 & ECBC 2017 (ECBC+ Building). All the light fixtures used for indoor applications should be available with DALI Dimmable driver option (for Apartments & Club Areas) 516 2ft x 2ft LED Panel - Surface Mounted.- Wattage : 30W -36W - Minimum System Efficacy-120 lm/W. 517 Downlight - Surface Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 518 Wall Bracket light- Wall Mounted.- Wattage : 10W -15W - Minimum System Efficacy-120 lm/W. 519 4ft LED Batten Tube Light -Surface Mounted.- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 520 4ft LED Batten Tube Light -Wall Mounted (IP-65)- Wattage : 36W -40W - Minimum System Efficacy-120 lm/W. 521 Mirror Light.- Wattage : 5W -10W 522 Bulkhead Wall mounted - Lumen Package 700 lm- Minimum System Efficacy - 100 lm/W 523 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 140-285V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 524 Supply, Installation ,Testingand Commissioning of Exhaust fansforexhaust air as shown on drawings. Eachfan shall be complete with permanent split capacitor, mountingplate andaccessorieslike wire guard, birdscreen andgravitylouvers forweatherprotection as required. Fan selection, arrangement andelectrical characteristics shall be as follows: 525 450 mm dia 900/1400 RPM fan suitable for 220+6%Volts, 50 Hz, single phase AC supply. 526 Main L.T. Panel :Supply& Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entrise Electrical control panel with TPN ACB (65 KA,4Pole Elect draw out , Micor processer Release IPR2) and TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type/digital ammeter Voltmeter,Selector switches for ammeter and Voltmeter, instrument fuses, current transormer etc. The Board shall have suitable capacity electrolytic aluminium busbars as per IS8623 insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/ DMC support with detEachable side covers and shall be suitable for extension on the sides. The switches entry boxes shall be complete with suitable cable end boxes reverse. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above Will be provided with Amp Metre, current transfomers and selector switches etc and insurtrment fuse. The switch board shall be fabicated with CRCA sheet with a minimum thickness of 1.6 mm/2mm.Cubicle type switch board shall be of cat A & B Only. CAT. B Cubicle TypeIncoming - 527 1600 Amp /415 Volt ACB -1 No.Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare) 528 Bus-Bar -1600 Amp /415 Volt ACB -1 No.Outgoing -200 Amp MCCB - 1 Nos.( to Audi block light panel )400 Amp MCCB - 1 Nos.( to Audi block AC panel )630 Amp MCCB - 1 Nos.( to fedder pillar panel )250 Amp MCCB - 1 Nos.( to fire pump room panel )40 Amp FP MCCB - 4 Nos.(Street light feeder pillar panel)200 Amp FP MCCB - 2 Nos.(Spare)FEEDER PILLAR PANEL: 529 Incoming -630 Amp MCCB - 1 No.Outgoing - 200 Amp 4P MCCB - 3 Nos. 100 Amp 4P MCCB - 2 No.100 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for Spare)(Complete as per requirment directed by Project Manager.) 530 Design, manufacture, testing at works, supply, including supervision during installation testing & commissioning of following floor / wall mounted clad switchboard, factory built, modular, sectionalised, dead front, fully compartmentalized with hinged lockable detachable front & back openable, Form IIIB type extensible Partial Type Tested Assembly, IEC-60439 compliant LT cubicle panel of suitable size, suitable for operation on 415 volts, 50 Hz AC 3 phase 4 wire supply system fabricated from powder coated CRCA sheet steel, with all load bearing members of minimum 2mm thickness , all non-load bearing members of minimum 1.6mm thickness and minimum 3mm thick gland plates. The panels shall be fabricated in easily transportable sections, length, height, depth etc. to match with site condition, having vibration free structure with stiffeners provided as required. EXTERNAL LIGHTING PANEL 531 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 532 Supplying, installation, testing & commissioningof intelligent analog addressablephotothermaldetectorcompletewithmountingbase complete as required. 533 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 534 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 535 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 536 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 537 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 538 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 539 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 540 Supplying, installation, testing & commissioning of intelligent interface unit BACnet/ Modbus protocol i.e. supplying communication links between building management system and fire alarm control panel complete as required. 541 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 542 Supplying & laying of 2x1.5 sqmm fire survival armouredcable, 600/1000V rated with annealed copper conductorhaving glass mica fire barrier tape covered by an extrudedlayer of Cross Linkable Ethylene Propylene Rubber (EPR)insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 543 Supplying & Fixing in position GI Box for installation of detectors on true Ceiling complete as required to do the job in all respect in accordance with laid specification or upto the satisfaction of engineer in charge. 544 Supply, installation,testing and commissioning of EXIT light, self contained 6W luminaire complete with flush mounting frame ,sign label,fluorescent tube and battery and with label EXIT/RIGHT/LEFT/UP/DOWN as required.. 545 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 546 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 547 Supplying, installation, testing & commissioning of digital audio amplifier 150 Watt, 25V rms operating at 240 Volt AC Supply complete as required. 548 SITC of 1X500W/480W Class-D Amplifier with 2 independent channels and can provide automatic re-settable overcurrent, overload, overheating, overvoltage, under-voltage and DC protection 549 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 550 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. 551 speaker cable Two pair, 2-core, 1.5 sqmm 552 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 553 UPS & INVERTERS 554 Supply, installation, testing and commissioning of 10 kVA UPS, 3 phase (415 V + 15%) Volts input & 3 phase output (440 V + 1%), 50 Hz, 100% IGBT inverter & converter, Input harmonic Current THD 3% typical at 100% load, 6% maximum at 50% load and 30 min battery backup for UPS along with battery cabinet complete in all respect including supporting steel structure for UPS and Battery as required. Quotedprice shall be inclusiveof approved rating single core copper conductor cable connecting UPS and batteries. 555 EXTERNAL LIGHTING 556 Pole Light -Pole mounted - Lumen Package -4000/6500/7200/9200 lm- Minimum System Efficacy - 120 lm/W 557 Bollard - Surface mounted - Lumen Package - 300/400 lm - Minimum System Efficacy - 35 lm/W 558 Supply, Installation, Testing & Commissioning of Recessed Inground Up Light fixture 10 Watt LED , integral driver, protection IP 66, CLASS I as complete as required. (Tree Up Lighting) 559 Supply, installation, testing & commissioning of LED Post Top Luminaire consuming a system wattage of 36 - 42W & the luminaire shall be with system efficacy >75lm/W. Housing: Die Cast Aluminium , IP66 ,The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.9, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79& LM80 issued by LED manufacture along with Photo Biological Safety Standard. CAT REF: LT Primus PT 40Wor approved Equivalent. 560 Height = 5 MetresTop dia = 70mmminBottom Dia = 130mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 200 mm x 200 mm x 12 mm thick, suitable for mounting of light fixture 561 Height = 6 MetresTop dia = 70mmminBottom Dia = 155mm minThickness =3mmSingle arm pole suitable for mounting of with base plate of size 260 mm x 260 mm x 16 mm thick, suitable for mounting of light fixture 562 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 563 63 mm dia (OD-63 mm & ID-51 mm nominal) 564 120 mm dia (OD-120 mm & ID-103 mm nominal) 565 EXTERNAL LIGHTING PANELIncoming :One (1) No 100 Amp. 4P MCCB of 25KABreaking capacity Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch.One (1) No. (0-100A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) No. of Phase Indication Lamp each incomingBus Bar :One (1) No. 120 Amp.TPN aluminimum bus bar of suitable length.Outgoing :10 No.16 Amp DPMCB. (10 KA)SPARE & SPACE - 2 NoPanel described as above 566 SUBHEAD IV-MISCELLANEOUS 567 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc.conforming to IS 14930, Part II complete with fitting and cutting,jointing etc. in the existing trench, complete as required. 200mm Dia200mm dia 568 SUBHEAD V-EXTERNAL LIGHT 569 Conical Arch Street Lighting Pole of 6000mm Height suitable for mounting street light luminaires, made out of hot rolled steel grade E250, as per IS 2062:2011 and designed suitably for wind speedupto 50m/s wind conforming to IS 875: PART -3:1987. The perfect conical profile extends from the square base plate of MS (grade E250) of size 300mmx300mm, 16mm thick and facilitated with 4 elongated slots 48mm x 24mm at CC 215mm to suit the 500mm, J-type, M20 bolts (Grade 4.6). The cable entry hole Ø70mm is provided at the centre of the baseplate. The continuously tapered pole shall have top Ø 70 mm and bottom Ø 155 mm, 3mm thick suitable to mount an artistically designed and angularly curved arm bracket that suits the conical form factor of the pole. The pole should be Arched on the top to mount the luminaire with the help of bracket. A base compartment for weather proof control box is provided at a height 300mm above the base plate with a die cast door contoured to the poless shape housing the gear tray, prewired with 2.5 Sq.mm cable, Siemens/Anchor make MCB, terminal connectors for loop in loop out arrangement. The make of poles should be as per Ligman/RR Ispat/Klite. The surface preparation of the pole & components shall be done by shot blasting which is environmentally safe eliminating the chemical and acid use and ensuring the thorough removal of impurities like, rust, oxides and other unwanted particles from the surface for high standard coating. The surface finish of the pole shall be Zinch rich primer coat & pure polyester powder coating providing 60 Microns DFT. with KL 4392 Avenue 100, Dimension 526x174 x 90 mm wattage upto 100w LED 570 Supply, Installation, Testing and Commissioning of LED RGB / RGBW flood lighting luminaire for facade lighting with Die-cast aluminium housing, powder-coated finish, of following wattage. Luminaire shall be capable of producing dynamic color changing light for with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100-270VAC, 50Hz with powerfactor > 0.9. Fixture shall be suitable to operate at an ambient temperature range of -10°C to + 50°Cand shall be IP65 and IK06 rated. Life time shall be at least L70:50000 burning hours at 50°C. Luminaire shall be conforming to BIS (IS10322 and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 30 W 571 Supply, Installation, Testing and Commissioning of LED RGB / RGBW Linear Wall Washer luminaire for Facade lighting with aluminium extruded housing, of following wattage. Luminaire shall be capable of producing dynamic color changing light with 16 million colors by DMX / Ethernet based control. The beam angle of the fitting shall be narrow, medium, wide or asymmetric as per the requirement. Luminaire shall be complete with driver and capable of operating at line voltage without any separate power supply from 100 to 270 VAC, 50 Hz, power factor > 0.9. Fixture shall be suitable to operate at ambient temperature range of-10°Cto+50°Cand shall be IP65 and IK06 rated. Life time should be at least L70 : 50000 burning hours at 50 C. Luminaire shall be conforming to BIS and shall be complete with all necessary accessories required for proper working of fixture including weather proof connection cables, water proof connectors etc. as required. 25 W 572 SITC OF DG SETS 573 Design, manufacturing, testing at works, supply of 3 Phase, 415V, 50 Hz and 1500 RPM Diesel Generator Set of following ratings. Engine shall be complete with turbo charger, base frame, lube oil system, Heat Exhanger (HE cooled), Control Panels, Electric Starter 24V DC, required batteries, battery charging alaternator, electronic governor, instrumentation, day service diesel fuel tank, exhaust silencers including insulation, engine mounted control panel with monitoring and alarm features, utility piping, anti-vibration pads, Alternator direct coupled to Engine along with static excitation system and AVR Panel, and all required accessories complete as required and as per the specifications. The scope of work shall not include AMF Panel, cabling and earthing. DG shall be procured to the standards as in MoEFCC notification No.Q-1s017losl 2OL2-CPW and GSR 804(E) dated 03.1 1 .2022 The DG Set shall be provided with genset controller for AMF,Auto-load sharing, and shall have electrical and mechanical parameter monitoring. The controller shall include following electrical protections - under & over frequency and voltage, overload (KW), overcurrent, short circuit, reverse power, excitation failure etc. 62.5 KVA(with Acoustic Enclosure) 574 Supply of 4mm thick MS diesel day oil tank duly painted with two coats of primer after pre-treatment, and one coat of synthetic enamel paint with manhole, inlet and outlet connections with gate valves, drain plug, piping between tank and engine incase of inbuilt day oil tank, vent, mechanical oil level indicator, low level/ high level alarms, including support arrangement etc. mounted on suitably painted MS staging to maintain gravity flow of diesel oil from tank to DG Set. 575 120 Litres Capacity for 62.5kVA DG set 576 Fuel Pipe Line & Misc. Items Works 577 Supply, installation, testing & commissioning of 40mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 578 Supply, installation, testing & commissioning of 25mm dia MS C Class fuel supply and return piping from diesel day oil tank to the DG Set, including all necessary fittings like tees, bends, ball valves etc. complete in all respects as per the specifications. 579 Providing and fixing of Valves and NRV for fuel line of following sizes: 580 40mm ball valve 581 25mm ball valve 582 40mm NRV valve 583 25mm NRV valve 584 BOUNDARY WALL WITH GATES 585 CARRIAGE OF MATERIALS 586 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 587 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil 588 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 589 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 590 Centring and shuttering including strutting,propping etc. and removal of form for 591 Foundations, footings, bases of columns etc. for mass concrete. 592 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 593 Columns,Pillars, Piers, Abutments, Posts and Struts 594 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 595 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 596 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 597 All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum 598 All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum 599 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 600 300 mm dia piles 601 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 602 300 mm dia piles 603 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) 604 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 605 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 606 Hot finished welded type tubes 607 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 608 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works 609 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 610 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 611 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. Two or more coats on new work including priming coat of ordinary paint approved brand. 612 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 613 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 614 Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto 1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately). 615 White sand stone - 30mm thick gang saw cut stone 616 Providing and fixing structural steel frame (for dry cladding with 30 mm thick gang saw cut with machine cut edges sand stone) on walls at all heights using M.S. square/ rectangular tube in the required pattern as per architectural drawing, including cost of cutting, bending, welding etc. The frame work shall be fixed to the wall with the help of M.S. brackets/ lugs of angle iron/ flats etc. which shall be welded to the frame and embedded in brick wall with cement concrete block 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) of size 300x230x300mm, including cost of necessary centring and shuttering and with approved expansion hold fasteners on CC/RCC surface, including drilling necessary holes. Approved cramps/ pins etc. shall be welded to the frame work to support stone cladding, the steel work will be given a priming coat of Zinc primer as approved by Engineer-in-charge and painted with two or more coats of epoxy paint (Shop drawings shall be submitted by the contractor to the Engineer-incharge for approval before execution). The frame work shall be fixed in true horizontal & vertical lines/planes. (Only structural steel frame work shall be measured for the purpose of payment, stainless steel cramps shall be paid for separately and nothing extra shall be paid). 617 Providing and fixing adjustable stainless steel cramps of approved quality, required shape and size, adjustable with stainless steel nuts, bolts and washer (total weight not less than 260 gms), for dry stone cladding fixed on frame work at suitable location, including making necessary recesses in stone slab, drilling required holes etc complete as per direction of the Engineer-incharge. 618 Applying breathable, non-reactive, antifungal, and water repellant Silane/Siloxane chemical as approved by Archaeological Survey of India/ Engineer-in-charge, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the existing sand stone masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer-In-charge (The rate is inclusive of all materials & labours involved except scaffolding). 619 ESS 620 Carriage of good earth by mechanical transport including loading, unloading and stacking (upto 20KM) 621 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 622 All kinds of soil 623 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 624 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 625 Supplying chemical emulsion in sealed containers including delivery as specified. 626 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 627 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 628 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 629 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 630 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 631 Centring and shuttering including strutting,propping etc. and removal of form for 632 Foundations, footings, bases of columns etc. for mass concrete. 633 Suspended floors, roots, landings, balcnies and access platform. 634 Shelves (Cost in situ) 635 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 636 Columns,Pillars, Piers, Abutments, Posts and Struts 637 Weather shade, Chajjas, corbels etc., including edges 638 Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc. including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured) Suspended floors, roofs, landing, beams and balconies (Plan area to be measured). 639 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 640 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 641 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 642 All works upto plinth level 643 Concrete of M25 grade with minimum cement content of 330 kg /cum 644 All works above plinth level upto floor V level 645 Concrete of M25 grade with minimum cement content of 330 kg /cum 646 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) :300 mm dia piles 647 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 648 300 mm dia piles 649 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 650 Cement mortar 1:6 (1 cement : 6 coarse sand) 651 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 652 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100mm/125mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 653 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 654 Hot finished welded type tubes 655 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 656 80x1.25 mm M.S. laths with 1.25 mm thick top cover 657 Providing and fixing ball bearing for rolling shutters. 658 Extraforprovidingmechanicaldevice chain andcrankoperation for operating rolling shutters. 659 Exceeding 10.00 sqm and upto 16.80 sqm in the area. 660 Extra for providing grilled rolling shutters manufactured out of 8mm dia.M.S. bar instead of laths as per design approved by Engineer-in-charge.(area of grill to be measured). 661 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 662 25 mm thick 663 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 664 15 mm cement plaster on the rough side of single or half brick wall of mix : 665 1:6 (1 cement: 6 coarse sand) 666 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 667 6 mm cement plaster of mix : 668 1:3 (1 cement : 3 fine sand) 669 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 670 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 671 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 672 Two or more coats on new work including priming coat of ordinary paint approved brand. 673 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 674 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 675 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 676 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : 677 In 75x75 mm deep chase 678 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 679 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) : For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 680 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 681 Powder coated aluminium (minimum thickness of powder coating 50 micron) 682 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 683 GUARD ROOM 684 Carriage of good earth by mechanical transport including loading, unloading and stacking 685 (upto 20KM) 686 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 687 All kinds of soil 688 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 689 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 690 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 691 Diluting and injecting chemical emulsion for pre-constructional anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration. 692 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 693 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 694 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 695 Centring and shuttering including strutting,propping etc. and removal of form for 696 Foundations, footings, bases of columns etc. for mass concrete. 697 Suspended floors, roots, landings, balcnies and access platform. 698 Shelves (Cost in situ) 699 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 700 Columns,Pillars, Piers, Abutments, Posts and Struts 701 Edges of slabs and breaks in floors and walls Under 20 cm wide 702 Weather shade, Chajjas, corbels etc., including edges 703 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 704 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 705 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 706 All works upto plinth level 707 Concrete of M25 grade with minimum cement content of 330 kg /cum 708 All works above plinth level upto floor V level 709 Concrete of M25 grade with minimum cement content of 330 kg /cum 710 Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete. (Length of pile for payment shall be measured upto to the bottom of pile cap) : 711 300 mm dia piles 712 Extra over single under ream for providing additional bulbs in under reamed piles, under specified diameter(only the nos. of extra bulbs are to be paid) 713 300 mm dia piles 714 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: 715 Cement mortar 1:6 (1 cement : 6 coarse sand) 716 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 717 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 718 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 719 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 720 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 721 Rectangular or square. 722 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 723 1.0 mm thick 724 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 725 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 726 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 727 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 728 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 729 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 730 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm 731 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm 732 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade 733 Area of slab upto 0.50 sqm 734 Area of Slab over 0.50sqm 735 Extra for providing edge moulding to 18mm thick marblestone counters, Vanities etc. including machine polishing to edge to give high glossfinishetc.completeasper designapprovedbyEngineer-in-Charge. 736 Granite work. 737 Extra for fixing marble /granite stone over and abovecorresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc. complete. 738 15 mm cement plaster on the rough side of single or half brick wall of mix : 739 1:6 (1 cement: 6 coarse sand) 740 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 741 6 mm cement plaster of mix : 742 1:3 (1 cement : 3 fine sand) 743 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 744 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : 745 New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 746 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade. 747 Two or more coats on new work including priming coat of ordinary paint approved brand. 748 Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 749 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 750 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 751 12.5 mm thick tapered edge gypsum moisture resistant board 752 Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mmthick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm, cross - T of size 24x32 mm of length 1200 mm and secondary intermediate cross-T of size 24x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6mm fixed with grid and Z cleat of size 25x37x25x1.6mm thick with precut hole on both 25mm flange to pierce into 12x50mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge. 753 With 15 mm thick Tegular edged light weight calcium silicate false ceiling tiles 754 Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 gsm/sqm, both side inclusive) consisting of main T runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross T of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main T at 600mm center to center to form a grid of 1200x600 mm and secondary cross T of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 x mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer-in-charge.GI Metal Ceiling Lay in perforated Tegular edge global white color tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. 755 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65mm. 756 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 757 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 758 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing and paneling to be paid for separately) :For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron) 759 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of PVC / neoprene gasket required (Fittings shall be paid for separately). 760 Powder coated aluminium (minimum thickness of powder coating 50 micron) 761 Providing and fixing 6 mm thick high performance toughened glass from approved manufacturer complete in all respects as per direction of the Engineer-in-charge. (Required properties Solar factor 0.43, U-Value (W/sq.m-K) 5.6, Visible light transmittance 0.43). The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. 762 UNDER GROUND TANK (UGT) 763 Carriage of good earth by mechanical transport including loading, unloading and stacking 764 (upto 20KM) 765 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 766 All kinds of soil 767 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. 768 All kinds of soil (From 1.5 to 3 m depth) 769 All kinds of soil (From 3.00 to 3.50 m depth) 770 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 771 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 772 Centring and shuttering including strutting,propping etc. and removal of form for 773 Foundations, footings, bases of columns etc. for mass concrete. 774 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc. 775 Suspended floors, roots, landings, balcnies and access platform. 776 Shelves (Cost in situ) 777 Lintels, beams, plinth bams, griders, bressumers and cantilevers. 778 Columns,Pillars, Piers, Abutments, Posts and Struts 779 Stairs, (excluding landings) except spiral-staircases 780 Edges of slabs and breaks in floors and walls 781 Under 20 cm wide 782 Weather shade, Chajjas, corbels etc., including edges 783 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 784 Steel reinforcement for R.C.C. work including straightening, cutting, bending,placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 785 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. 786 All works upto plinth level 787 Concrete of M25 grade with minimum cement content of 330 kg /cum 788 All works above plinth level upto floor V level 789 Concrete of M25 grade with minimum cement content of 330 kg /cum 790 Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 791 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 792 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 793 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 794 Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): 795 Rectangular or square. 796 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality. 797 1.0 mm thick 798 Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type, 22mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 799 Providing and fixing approved brand and manufacture SS 304 grade SS 304 grade Mortise Dead Lock with 60mm Backset fixed fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 800 Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 801 Providing and fixing approved brand and manufacture SS 304 grade wall mounted door buffer fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 802 Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 803 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. 804 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 805 Hot finished welded type tubes 806 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 807 25 mm thick 808 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 809 Extra for pre finished nosing to treads of steps of Kota/Sand stone. 810 Extra for Kota/Sand flooring in treads of steps and risers using single length above normal size up to 2.00 metre . 811 Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. 812 Providing and laying matt finished vitrified tile of size 300x300x9.8mm having with water absorption less than 0.5% and conforming to IS: 15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge. 813 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc., complete. 814 12mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 815 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 816 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) 817 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 818 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour :New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre 819 Painting with synthetic enamel paint of approved brand and manufacture of required color to give an shade.Two or more coats on new work including priming coat of ordinary paint approved brand. 820 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 821 Providing & fixing galvanized low carbon wire, anealed wire Chicken mesh formed by twisting two adjacent wires at least four times, forming a hexagonal shaped strong honeycomb mesh structure on joints of RCC & Brick work before plastering, of required gauge (not less than 21 gauge)and size with nails etc. complete as specified in drawing and as per the Direction of Engineer-in-charge. 822 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineering-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge : 823 In 75x75 mm deep chase 824 Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. 825 Road Work 826 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 827 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 828 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 829 All kinds of soil 830 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 831 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 832 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 833 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 834 Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 835 Providing and laying 400 micron thick PVC Sheet on WBM Surface complete as per direction of engineer-in-charge. 836 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverable separately). 837 Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.) 838 Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. Using grade A sealing compound conforming to IS: 1834. 839 Painting runway/taxi track/apron marking with adequate no. of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge i/c cleaning the surface of all dirt, scales, oil, grease and other foreign material etc. and lining out complete 840 New work (Two or more coats) 841 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement in position to the required line , level and curvature jointed with cement mortar 1:3 (1 cement : 3 coarse sand) including making joints with or without grooves (thickness of joints except sharp curve shall not be more than 5mm) including making drainage opening wherever required complete etc. as per direction of engineer-in-charge (length of finished kerb edging shall be measured for payment).(Precast C.C. kerb stone shall be approved by engineer-in-charge). 842 FOOTPATH & STONE BENCHES 843 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. 844 All kinds of soil 845 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 846 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) 847 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth & above plinth level. 848 Thermo-Mechanically Treated bars of grade Fe-500D or more. 849 Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 850 Providing and fixing 70 mm thick Lalitpur Grey sand stone over prefix sand stone legs including polishing, pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone. 851 Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge. 852 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: 853 All kinds of soil 854 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 855 Extra for compaction of earth work in embankment under optimum moisture conditions to give at least 95% of the maximum dry density (proctor density). 856 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. 857 With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBRValue-30 858 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 859 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 860 HORTICULTURE & LANDSCAPING WORK 861 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of serviceable materials and then disposing of surplus soil, by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge or/and manure before and after flooding trench with water (excluding cost of imported earth, sludge or manure). 862 Supplying and stacking of good earth at site including royalty and carriage up to 1 km (earth measured in stacks will be reduced by 20% for payment). 863 Supplying and stacking at site dump manure from approved source, including carriage up to 1 km (manure measured in stacks will be reduced by 8% for payment) : 864 Screened through sieve of I.S. designation 20 mm 865 Screened through sieve of I.S. designation 16 mm 866 Screened through sieve of I.S. designation 4.75 mm 867 Fine dressing of the ground 868 Spreading of sludge, dump manure and / or good earth in required thickness as per direction of Officer-in-charge (Cost of sludge, dump manure and / or good earth to be paid separately). 869 Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge.. 870 Providing and laying Neelgiri/Korean grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light watering with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. 871 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) : 872 Holes 60 cm dia, and 60 cm deep. 873 Holes 45 cm dia, and 45 cm deep. 874 TREE PLANTS 875 Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 876 Providing and stacking of Bauhinia purpurea (Kachnar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 877 Providing and stacking of Azadirachta indica ( Neem ) of height 120-130cm in big polybag of size 25 cm as per direction of the officer-in-charge. 878 Providing and stacking of Mimusops elengi (Maulsri) of height 180-195 cm., well developed with thick stem in big in big size HDPE bag as per direction of the officer-in-charge. 879 Providing and stacking of Callistemon lanceolatus of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 880 Providing and stacking of Saraca indica (Sita Ashok) of height 105-120cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. 881 GROUND COVERS PLANTS 882 Providing and stacking of Tradescantia, full of leaves in Earthen Pot/Plastic Pot of size 15 cm. as per direction of the officer-in-charge. 883 Providing and stacking of Wedelia trilobata,full of leaves in 15 cm size of Earthen Pot/Plastic Pot & as per direction of the officer-in-charge. 884 Providing and stacking of Syngonium golden of height 30-45 cm. with 2-3 suckers healthy foliage in Earthen Pot/Plastic Pot of size 20 cm. as per direction of the officer-in-charge. 885 SHRUBS AND PERINNIAL HERBS 886 Providing and Displaying Bougainvillea named variety, Sobhra, Thima, Marry palmar, Cherry Blossom etc. well developed with fresh & healthy bushy in full bloom 75 to 90 cm ht. in 40 cm Cement Pot as per direction of the officer-in-charge. 887 Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. 888 Providing and stacking of Ficus panda of height 60-75 cm, with 8-10 branches, and healthy foliage, bushy in big size HDPE bag as per direction of the officer-in-charge. 889 CREEPER PLANTS 890 Providing and stacking of Quisqualis indicia of height 30 cm to 45 cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 891 Providing and stacking of Clerodendrum splendens of height 30 cm to 45cm. in 20 cm size of Earthen pots / Plastic pots & as per direction of the officer-in-charge. 892 FURNITURE AND FURNISHINGS 893 Cafe Table, S.S. Pipe Frame, PLPB Edge Banded Top, 38mm Thick, Size in mm - 900mm (Dia.) 894 Café Chair, PP Seat & Back 895 DiningTable, Powder Coated + Chrome Plated Pipe Frame, PLPB Edge Banded Top, 25mm Thick, Size in mm - 1500 X 900 896 Medium Back Chair, PU Arms, Silver Powder Coated Pipe Frame,Gas Lift, Powder Coated Base, Seat Back Leatherite Tapestry. 897 Reception Table, Particle Board Top 898 2 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 1180 (L) X 835 (D) X 785 (H) 899 Centre Table, 18mm PLPB Top, Annodize Aluminium Section Frame 900 Corner Table, MDF Top With Veneer Polish, MS Gold Finish Leg 901 1 Seater Sofa With Wooden Frame, Powder Coated Leg, Twin Colour Leatherette Tapestry Size in mm - 810 (L) X 835 (D) X 785 (H) 902 Medium Back Chair, Wooden Frame, Cushion Arm, Synchro Knee Tilt, Gas Lift, Aluminium Base 903 Visitor Chair, Wooden Frame, Cushion Arm, Chrome Plated pipe stand 904 Executive Table, PLPB Top, Flaper Box, Extruded Aluminium Profile 905 Conference Table, Particle Board Edge Banded Top 906 Medium Back Chair, PP Cushion Arm, Swivel Tilt, Gas Lift, Nylon Base 907 Executive Table, Particle Board Top, Fixed Metal Pedestal, Metal Frame, Powder Coated 908 Visitor Chair, Cushion Arm, PU Moulded Seat Back, Chrome Plated Pipe stand 909 Bunk Bed, CRCA Pipe Frame, Powder Coated, PPCP Shoes, With 12mm Plywood, Without Mattress Uppder Size- 1950 X 965 Lower Size- 1950 X 1250 910 Study Table, Particle Board Top, MS Powder Coated Legs 911 METAL BED 912 WARDROBE WITH MIRROR ,PLPB BOARD 913 SUBHEAD I-EARTHING 914 Supply and burying of 40mm dia x 4.5 metres long G.I. Pipe vertically for earthing having 12mm dia. Holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No. 6 to 8 SWG GI wire in G.I. Pipe up to appron (and from appron to switch board the cost of G.I. wire and pipe will be extra) upto switch board, 30cm square C.I. box with hinged cover masonary enclosure, funnel at top, alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all respects as per drawing. 915 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required 916 Supply and burying of 600mm x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and two earthing lead of two no. 8 SWG copper wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and copper wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. complete in 917 all respects. 918 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 919 Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 920 50 sqmm3.5 core 921 6 sqmm3 core 922 6 sqmm2 core 923 Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 924 50 sqmm3.5 core 925 6 sqmm3 core 926 6 sqmm2 core 927 Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 928 50 sqmm 929 GST Extra as per applicable
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
49.
Public Administrative Department #9463829 Technical Bid
Tender for the remaining work (development work and electrification work) of Sanskriti School under construction under CG City Scheme, 1 ROAD WORK 2 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. DSR 16.1 3 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD SOR 4 Providing and laying design mix cement concrete of M-30 grade, inroads/ taxi tracks/ runways, using cement content as per designmix, using coarse sand and graded stone aggregate of 40 mm nominalsize in appropriate proportions as per approved & specified designcriteria, providing dowel bars with sleeve/ tie bars wherever required,laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdyM.S. channel sections, curing, making provision for contraction/expansion, construction & longitudinal joints ( 10 mm wide x 50 mmdeep) by groove cutting machine, providing and filling joints withapproved joint filler and sealants, complete all as per direction ofEngineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Cement content in M-30 is @ 340 Kg/Cum. Excess/Less cement Used as per design mix is separately.DSR 16.43.2 5 Providing and fixing in position pre-moulded joint filler in expansion joints.DSR 16.45 6 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD SOR 504 7 PARKING 8 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 9 Construction of granular sub-base by providing close graded Materialspreading in uniform layer with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per clause 401. PWD 10 Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturers specifications & direction of Engineerin-Charge. 80mm thick Cement concrete paver block of M-30 grade with approved colour, design & pattern. DSR 16.91.2 11 Providing, laying and making kerb channel 30 cm wide and 50 mm thick with cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth etc. complete and as per direction of Engineer-in-charge. DSR 16.63 12 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment. (Precast C.C. kerb stone shall be approved by Engineer-in-charge). DSR 16.69 13 DRAIN 14 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.DSR 2.8.1 15 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)DSR 4.1.8 16 Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in- considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately). All works upto plinth level DSR 5.33.1 17 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level PWD 504 18 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 (1 cement: 3 fine sand) DSR 13.7.1 19 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2 20 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work DSR 13.61.1 21 Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.DSR 23.9 22 COLUMN UPTO 10 FT 23 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6. 24 Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work,including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete,improve workability without impairing strength and durability as per direction of the Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately) All works upto plinth level DSR 5.37.1 25 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 26 RETAINING WALL 27 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 28 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 29 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 30 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 31 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III): 6 graded stone aggregate 40 mm nominal size). DSR4.1.6 32 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 33 Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. DSR 5.9.2 34 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 35 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 36 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 37 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For vertical surface two coats @0.70 kg per sqm per coat DSR 22.23.1 38 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side.The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guaranteed for 10 years against any leakage. For horizontal surface one coat @1.10 kg per sqm DSR 22.23.2 39 Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone. DSR 22.1.1 40 Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : Using rough Kota stone DSR 22.2.1 41 SKYLIGHT & BRICK WORKS 42 Providing & fixing of roof with multilayer standing seam polycarbonate panel system of 18mm thickness (min) including all standard fixing accessories on top of the supporting structure (paid extra) complete & as per the direction of the engineer in charge. The panels should work on angular daylighting concept with translucent and opaque combination of louvers inside, for better thermal insulations and diffusion of light especially with white and clear combination designed for tropical regions & shading throughout the day for better ambient temperature below the roof. Panels shall have minimum seven layers with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. The entire panel system shall be with a width from min 1200mm. Bigger width and minimal junctions should be preferred for better performance. Panels shall be manufactured with vertical offset standing seam at both sides of the panel. Panels have to be fixed on purlin with snap on connectors with grip lock double tooth locking mechanism and will be secured on MS Structure/ purlins (will be paid separately) with HDSS Fastener and double tooth polycarbonate connector for best stability and having a pull-out load of min 7000N (7KN) tested as per ISO 6892:1998 and IS 1608:2005. Panels cell structure be in truss bridge design or commonly called X structure for better strength and stability. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on polycarbonate panel which have been exposed to UV for a min. of 500 hours as per ASTM G155. Panels shall not have yellowness Index as per ATSMD 1925 of 15 units when tested on a sample exposed to UV for 500 hours as per ASTM G 155. U value shall not be more than 2.0W/m2K as per EN ISO 10077-2:2018. Panel shall be with additional End cp/ Aluminium U/F profile/ Glazing Bar (all mill finish) for ends as required. Trained and factory authorized layout with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge.Colour: as per approval. 43 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. 44 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.4.2 45 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) DSR 13.4.2 46 15 mm cement plaster on rough side of single or half brick wall of mix: 1:6 (1 cement: 6 coarse sand) DSR 13.5.2 47 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 48 Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) DSR 13.46.1 49 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 50 CHAIN LINK FENCING 51 Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. DSR 2.8.1 52 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 53 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 54 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 55 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) DSR 4.1 56 Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete DSR 5.9.1 57 Centering and shuttering including strutting, propping etc. and removal of form for : Columns, Pillars, Piers, Abutments, Posts and Struts DSR 5.9.6 58 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.37.1 59 Steel reinforcement for R.C.C.work including straightening, cutting, bending, placing in position and binding all complete upto plinth level 60 Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade DSR 16.70.2 61 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel rimer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes DSR 10.16 62 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 63 M.S. GRILL WORKS 64 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding DSR 9.48.1 65 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece DSR 10.5.2 66 Providing and fixing angle iron frames for doors, windows and ventilators of mild steel Angle sections of size 35x35x5 mm, joints mitred and welded by angle iron 35x35x5 mm or 35x 5 mm flat pieces to the existing T-iron frame or to the wall with dash fastener, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer, all complete as per the direction of Engineer-In-charge. 67 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 68 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62.1 69 BASEMENT WORK 70 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 71 Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos emulsifiable concentrate of 20% DSR 2.34 72 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos E.C. 20% with 1% concentration DSR 2.35.3.1 73 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand (zone-III): 10 graded stone aggregate 40 mm nominal size). DSR 4.1.10 74 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick DSR 11.26.1 75 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 76 BASKETBALL COURT 77 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 78 Synthetic Specification: -Providing and laying of ITF Classified material. 8 layers System Synthetic Acrylic for Synthetic Basketball Court:-(1 layer) Conrete Primer(2 layer) Resurfacer(3 layer) Cushion Rubber(4 layer) Top CoatWhite Line Marking as per standard 79 Basketball pole fix type 6” round pipe , Projection 2*20 Acrylic board 20mm Malaysia with dunking ring (3 spring) 80 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P. 81 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 82 SPORTS FACILITIES 83 LAWN TENNIS COURT 84 Concrete Base:-Providing and laying of 75 mm thick PCC, 75mm RCC with 6mm bar, spacing 300 C/C as per slope & level specified by concern federation . 85 Synthetic Specification: -Providing and laying of ITF Classified imported material (AcryCoat Made In Europe)8 layers System Synthetic Acrylic for Synthetic Court :-• (1 Layer) Concrete Primer • (2 layers) Acrylic Resurfacer• (3 layers) Cushion • (2 layers) Top Coat•Line Marking 86 Providing and fixing chain link fencing made with vertical pipe of 50 mm & horizontal 40 mm OD MS pipe frame size of 3 m x 3 m with 2”x2” of 10 SWG hot dip galvanized chain link fencing fixed with nut bolt/wire for ms flat patti and complete with all T&P 87 Providing and fixing of lighting as per details. Nos of pole-4 nos with 20 ft light, Metel halide light 400 wt on each pole. No of MCB-05 ,cable, junction box with complete fit. 88 Pole socket type 80*80 mm , thickness (4 mm) with net 89 SKATING RING 90 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres.DSR 16.1 91 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/ recoverableseparately). DSR 16.75 92 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar worksDSR 10.25.2 93 Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign mater;al etc. and lining out complete.New work (Two or more coats) DSR 16.47.1 94 HORTRICULTURE AND LANSCAPING 95 Supply and stacking of of good earth at site including royaltyand carriage up to 1 Km DSR 2.2 96 Supply and stacking of sludge at site including royalty and carriage up to 1 Km DSR 2.3 97 Supply and stacking of dump manure from approved source at site including carriage up to 1 Km DSR 2.4.3 98 Rough dressing the trenched ground including breaking of clods DSR 2.5 99 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.6 100 Uprooting weeds from the trenched area after 10 to 15 days of its flooding with water including disposal of uprooted vegetation. DSR 2.7 101 Spreading of sludge, dump manure and or good earth and mixing as per direction of engineer incharge DSR 2.8+2.9 102 Grassing with selection No-1 grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn. free from weeds and fit for moving and disposal of rubbish as directed DSR 2.10.1 103 Half brick circular treeguard in brick 1.25 m internal dia and of ht 1.20 m above ground and 0.20 m below ground..... DSR 2.15 104 Anti termite treatment by digging pits 30 cm deep and 4 cm dia, 6 to 7 holes around the tree using chemical emulsion at the rate of 1.5 liter per hole in two time or more application to get the trees free from termite infection chemicals used Chlorpyriphos 20% EC in the ratio of 1% concentration and as per direction of officer-in-charge. DSR 2.54 105 Anti termite treatment of lawn area through premise 30.50% I P. one liter premise diluted in 499 liters water and applying solution @ 1.00 litre solution per sqm lawn or bed area.(two application) i/c cost of chemical)and as per direction of officer-in-charge.and as per direction of officer-in-charge. DSR 2.56 106 Supply and stacking of Azadirachta indica ( Neem ) plant of height 120- 130cm in big polybag of size 25 cm as per direction of the officer-in-charge DSR 7.5 107 Supply and stacking of Delonix regia (Gulmohar) plant of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge DSR 7.24 108 Supply and stacking of Ficus bengalensis (Bargad) plant of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. DSR 7.28 109 Supply and stacking of Ficus elastica Decora (Rubber plant) plant of height 45-60 cm. in earthen pots of size 25 cm as per direction of the officer-in-charge.DSR 7.31 110 Supply and stacking of Phoenix sylvestris Roxb. (Wild date palm/khajur) of height 150-165 cm. in Big HDPE Bag as per direction of the officer-incharge DSR 7.63 111 Supply and stacking of Polyalthia longifolia (Ashok) plant of height 180- 195 cm. in gunny bag of size 30 cm as per direction of the officer-incharge. DSR 7.75 112 Preparation of mounds of various size and shape by available excavated / supplied earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc., lead upto 50 meter and lift upto 1.5 m complete as per direction of Officer-in-charge DSR 2.28 113 Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge DSR 2.33 114 Plumbing Detail 115 SANITARY FIXTURES 116 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device(handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR 17.1.1 117 Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre/8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. DSR 17.78 118 Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water ( 250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.. DSR 17.80 119 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR 17.31 120 Providing and fixing toilet paper holder : C.P. brass DSR 17.34.1 121 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single holebasinmixer. 122 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm. DSR 17.10.1.1 123 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 a) 15 mm nominal bore 15mm nominal bore DSR 18.53.1 124 Providing and fixing brass bib cock of approved quality : 15 mm nominal bore DSR 18.51.1 125 Providing and fixing brass stop cock of approved quality : 15 mm nominal bore DSR 18.16.1 126 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms. DSR 17.72 127 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in -charge. MR 128 Providing and fixing of SS coat hook complete in all respect as approved by Engineer In Charge MR 129 Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms.DSR 17.70.1 130 Providing and fixing of SS grab bar complete in all respect as approved by Engineer In Charge MR 131 Providing and fixing urinal partition chinaware complete in all respect MR 132 Providing and fixing of sink mixer complete in all respect. MR 133 Providing and fixing SS labourtory sink as per detailMR 134 Providing and fixing laboratory sink mixer complete in all respect.MR 135 Providing and fixing drinking water sink complete in all respects MR 136 SOIL , WASTE AND VENT SYSTEM 137 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings: 75 mm dia 138 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 100 mm dia 139 Providing and fixing soil, waste and vent pipes-Hubless centrifugally cast (spun) iron pipes as perIS:15905 with stainless steel coupling with EPDM rubber complete in all respectincluding all required fittings : 150 mm dia 140 Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : Hubless : 100 mm inlet and 100 mm outlet DSR 17.60.1 141 Providing and fixing PTMT grating of approved quality and colour. Circular type. 100 mm nominal dia. DSR 18.58.1.1 142 Providing and fixing floor clean out plug consist of CI bend & GI socket heavy class with Brass cap & key for opening male threaded cap etc. including lead caulked to CI pipescomplete in all respects as per drawing / sample approved by Engineer -in -ChargeFCO (floor clean out plug shall be flushed with floor finish: 100 mm dia/150 mm dia 143 Water Supply system 144 Inside Toilets 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge : External work. DSR 18.9 146 15 mm nominal outer dia. Pipes. 147 20 mm nominal outer dia. Pipes. 148 25 mm nominal outer dia. Pipes. 149 Distribution lines 150 Providing and fixing of GI Pipes medium class IS :1239 including all required fittings etc. DSR 18.12 151 20 mm dia. nominal bore 152 25 mm dia. nominal bore 153 32 mm dia. nominal bore 154 40 mm dia. nominal bore 155 50 mm dia. nominal bore 156 65 mm dia. nominal bore 157 80 mm dia. nominal bore 158 100 mm dia. nominal bore 159 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore DSR 18.13.1 160 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore DSR 18.13.2 161 Fixing water meter and stop cock in G.I. pipe line including cutting and threading the pipe and making long screws etc. complete (cost of water meter and stop cock to be paid separately). DSR 18.14 162 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore: DSR 18.17 163 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mm nominal bore. DSR 18.17.2 164 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore DSR 18.17.3 165 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore DSR 18.17.4 166 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore DSR 18.17.5 167 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore DSR 18.17.6 168 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore DSR 18.18.1 169 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20 mm nominal bore DSR 18.18.2 170 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore DSR 18.18.3 171 Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. 172 Providing and fixing submrsible vertical drainage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand bysolid hanldling 40 mm size.discharge 5 lps and head-15 mtr 173 Providing and fixing submrsible vertical sewage sump pumps in sumps including all required valve , fittings etc. complete in all respects. Fully auomatic type with level float control.Status (w+s)1 working + 1 stand by solid hanldling 40 mm size.discharge 5 lps and head-15 mtr 174 RAIN WATER SYSTEM 175 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 100 mm dia 176 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 150 mm dia 177 Providing and fixing of HDPE-80 pipes and fittings for rain water pipes complete in all respects. : 200 mm dia 178 Making of 600x600 mm size khurah complete in all respects including water proofing etc. 179 EXTERNAL SEWARAGE AND DRAINAGE 180 GARDEN IRRIGATION 181 Providing and fixing HDPE pipes conforming to IS:4984 PE 63 Class IV (6 kg/sqcm) including all fittings, e.g.couplings, tees, bends, reducers and screwed adoptors, welded joint as per manufacturers recommendations. 182 a) 32 mm O.D. 183 b) 40 mm O.D. 184 c) 63 mm O.D. 185 Providing and fixing uPVC Schedule 40 pipes conforming to ASTM D-1785complete with uPVC Schedule 40 fittings including necessary cutting of pipes, jointing with HDPE pipe with sadddle fitting completewith testing and commissioning of pipe lines : (a) 1 nominal size 186 Providing and fixing 25 mm brass dia quick coupling valve fitting with auto-close lid, SS spring, brass valve, complete in all respects (Harit model HT-71Bor eq.). 187 Providning and fixing bronze ball valve with screwed female/flangedends with stainless steel valve and spindle, glass fileed tefelon seating and gland packing, quarter turn lever operate full bore design, hydraulically tetsed to 20 kg/sqcm 188 a) 25 mm nominal bore 189 b) 40 mm nominal bore 190 a) 50 mm nominal bore 191 Providing and fixing cast iron flanged wafer type butterfly Valve with quarter turn operation complete in all respects confirming to IS:13095 PN1.0: (a) 65 mm dia 192 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. cover 500x450 mm R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 193 Providing and fixing 15 mm N.B. air release valve alongwith FTA I/c 1 no. ball valve for fixing to HDPE pipeline complete 194 Constructing masonry chamber 60x60x75 cms inside with 75 class designation brick work in cement mortar 1:5 (1cement : 5 fine sand) for sluice valve with C.I. surface box 100 mm top dia 160 mm bottom dia and 180 mm deep (inside) with chained lid and R.C.C. top slab 1:2:4 mix (1cement:2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 mix (1 cement : 5 fine sand and 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3(1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement and outside plaster finished rough complete as per standard design. 195 SEWERAGE 196 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 197 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil] : (b)Extra over 1 (a) above for excavation over 1.5 m depth . 198 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (a) 200 mm OD 199 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (b) 250 mm OD 200 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects: (c) 300 mm OD 201 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. :(a) 200 mm OD 202 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design. (b) 250 mm OD 203 Providing and fixing square mouth S.W. gully trap grade A complete with C.I. Grating brick masonary chamber with bricks of class designation 75 and water & gas tight SFRC Cover with frame of 260x260 mm size clear opening, frame of size 390x390 mm with weight of frame to be not less than 10 Kg and cover of size 300x300 mm with weightof cover not to be not less than 9 Kg as per standard design: (a) 180X 150 mm size P type with F.P.S. bricks of class designation 75 204 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 205 Extra for depth beyond 45 cm of brick masonary chamber : for 455X610 mm size : With F.P.S. bricks 206 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand)inside cement plaster 12mm thick with cement mortar1:3 ( 1 cement :3 coarse sand ) finished with floating coat of neat cement, foundation concrete 1:3:6 mix ( 1 cement 3 Coarse sand: 6graded stone aggregate 40mm nominal size) and making necessary channelin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) finished witha floating coat of neat cement all complete as per standard design: 0.91 m deep with SFRC cover and frame ( Heavy duty HD-20 gradedesignation) 560mm internal diameter conforming to IS:12592 total weightof cover and frame to be not less than 182 kg, fixed in cement concrete1:2:4 (1 cement:2 coarse sand :4 graded stone aggregate 20mm nominal size) including centering shuttering all complete. (excavation, foot rests and 12 mm thick cement plaster at the surface shall be paid seperately): with F.P.S. bricks class desigantion 75 207 Extra depth for circular type manhole 0.91 m internal dia (at bottom) with beyond 0.91 m to 1.67 m, withF.P.S. bricks class designation 75 208 DRAINAGE SYSTEM 209 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (a) Pipes, cables etc. exceeding 75 mm dia but not exceeding 300 mm dia. 210 Excavating trenches of required width for pipes, cables etc. including excavation for sockets and dressingof sides, ramming of bottom depth upto 1.5 M including getting out the excavated soil and then returning the soil as required in layers not exceeding 20 cms in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil as directed within a lead of 200 m. [All kinds of soil]: (b) Pipes, cables etc. exceeding 300 mm dia. 211 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(a) 200 mm OD 212 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 250 mm OD 213 Providing PVC-U sewer pipes confirming to IS:15328 (SN -10 kN/sqcm) with elastomeric sealing ring socket joints complete in all respects:(b) 300 mm OD 214 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (a) 200 mm OD 215 Providing and laying cement concrete 1:5:10 mix (1 cement: 5 coarse sand: 10 graded stone aggregate 40 mm nominal size) upto haunches of PVC-U pipes including bed concrete as per standard design.: (b) 250 mm OD 216 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (a) Inside size 90X80 cms and 60 cms deep including SFRC cover with frame (heavy duty) 500 mm dia clear opening 217 Constructing brick masonry manhole with 75 class designation bricks in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement:2 coarse sabd : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 ( 1 cement : 4 coarse sand : 8 garded stone aggregate 40 mm nominal size) inside and outside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand ) finished with floating coat of neat cementand making channelsin cement concrete 1:2:4 ( 1cement : 2 coarse sand :4 gradedstoneaggregate 20 mm nominal size ) neatly finished witha floating coat of neat cement all complete as per standard design. (All earthwork and plastic foot rests included): (b) Inside size 120X90 cms and 90 cms deep including SFRC cover with frame (Extra heavy duty) 560 mm dia clear opening. 218 Extra for additional depth of manholes: (a) Size 90X80 cms beyond 60 cms depth 219 Extra for additional depth of manholes: (b) Size 120X90 cms beyond 90 cms depth 220 Constructing brick masonary chamber for underground C.I. Inspection chamber with and bends with 75 class designation bricks in cement mortar 1:5 (1 cement: 5 fine sand) C.I. Cover with frame (light duty) 455X610 mm internal diamensions, total weight of cover with frame to be not less than 38 Kg (weight of cover 23 Kg and weight of frame 15 Kg) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) foundation concrete 1:5:10 ( 1cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455X610 mm and 45 cm deep for single pipe line With F.P.S. bricks 221 Constructing brick masonary road gully chamber 50X45X60 cm with bricksof class designation 75 in cement mortar 1:5 (1 cement: 5 fine sand) including 500X450 mm precast RCC horizontal grating with frame complete as per standard design:With F.P.S. bricks 222 Making connection of stormwater lines with existing municipal manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete: (a) For pipes 250 to 450 mm diameter 223 FIRE FIGHTING WORKS 224 FIRE FIGHTING 225 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(a) 80 mm dia ( 4.85mm thickness) 226 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(b) 100 mm dia ( 5.40mm thickness) 227 Supply, Installation, Testing and Commisioning in trenches the following sizes of M.S. class `C (heavy class) pipes conforming to IS:1239 with accessories like fittings including tees, elbows, reducers, flanges, rubber gaskets, G.I. nuts, bolts and washers and providing 150mm thick fine sand layer all around the pipe, including excavation in all kind of soil, refilling, ramming and removing the excavated surplus material and making good the same complete as required. Providing protection toembedded M.S pipesandfittingsbywrapping allaround 4mm thick pypkote protection including proper overlaps on joints.:(c) 150 mm dia ( 5.40mm thickness) 228 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(a) 100 mm dia 229 Supply, Installation, Testing and Commisioning of butterfly valve suitableforworking pressure 15 Kg/Sqcm.& test pressure 30kg/sqcm with flanges, nut bolts&gasketscomplete required.:(b) 150 mm dia 230 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(a) 100 mm dia 231 Supply, Installation, Testing and Commisioning of C.I. dual plate wafer type check valve suitableforworking pressureof15 Kg/Sqcm & test pressure 30kg/sqcm withflanges, Nut, bolts & washers, painting etc.completeas required.:(b) 150 mm dia 232 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:( a) 65 mm dia 233 Supply, Installation, Testing and Commisioning of double flanged flexicon expansion joint with unit control of standard length as per maufacturers specs tested to a pressure of 30Kg/Sqcm including rubber gaskets, flanges, nuts, bolts and washers complete as required.:(b) 150 mm dia 234 Supply, Installation, Testing and Commisioning ofC.I.`Y strainer with bronzeperforatedsheetbasket includingrubber gasket, flanges, nuts, bolts and washers, complete as required.: (a) 150 mm dia 235 Supply, Installation, Testing and Commisioning of SS single head fire hydrant valvewith80 mm N.B.flangedinlet, brass spindal, one no. 63 mm dia femaleinstantaneousoutlet type. G.M. coupling,blank cap, chain. Conforming to IS:5290.Includingtappingfromwet riser complete as required. 236 Supply, Installation, Testing and Commisioning ofHose pipe, 63 mm diaand15mts long, duly reinforced, rubberlined suitable forbrusting pressurenot lessthan22Kg/Sqcm. conformingtoIS 636-1988type A with gun metal heavy dutyinstantaneous type coupling ( Pairmale&femaleparts) conforming to IS 903. Complete as required. 237 Supply, Installation, Testing and Commissioning of63 mm dia instantaneouspattern branchshort SSpipe,16 mmdia nozzle conforming to IS 903, suitable for inter connection to hose pipe coupling complete as required. 238 Supply, Installation, Commisioning of standard firemans axe with heavy rubber handle. 239 Supply, Installation, Testing and Commissioning ofinletbreaching havingC.I.bodyfourway SS 63 mm diainstantaneousinlets conforming toIS 903fittedwithnon returnvalves, 25 mm diagun metal drain cock, blank cap, brasschains and 150 mm dia flanges with allaccessories suitableforlocal fire tender complete as required. 240 Supply, Installation, Testing and Commissioning ofSS Fire Brigadeadopter assemblywith150mm diaoutlet,suitableforlocalfire tender complete as required. 241 Supply, Installation, Testing and Commissioning of weather proof cabinet of size not less than0.6 x 0.6 x 0.45 mtr made out of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass doors (Two nos.)suitably markedon the outside with the letters FIRE HOSE including necessary lockingarrangement and painting in red coloursuitableto accomodate, externalyard hydrant valve, 2 nos15 mtrlongHose pipe, branch pipe, nozzle and fire mans axe. It shall be mounted on boundary wall complete as required. 242 Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required :Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.: Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS-325.: M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.2280 lpm at 70 m Head 243 Supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump): Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.: 2280 lpm at 70 m Head 244 Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) : Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520.: Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-F insulation, conforming to IS : 325.: M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.: Suitable cement concrete foundation duly plastered and with anti vibration pads. : 180 lpm at 70 m Head 245 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required : 246 INCOMING:250A, 50kA 4 Pole MCCB, Ics=100% Icu ratingDigital Voltmeter 0-500V with selector switchDigital Ammeter (0-250 A) with selector swtich & CTs etc:LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300AOUTGOING:( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps)Main Fire Pump125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. 247 Jockey Pump : 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.DIESEL ENGINE CONTROL 248 Control for diesel engine comprising -Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification 249 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe 250 Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 251 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. 252 FINISHING WORK 253 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) DSR 21.1.1.2 254 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately): Powder coated aluminium (minimum thickness of powder coating 50 micron)DSR 21.1.2.2 255 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides DSR 21.2.2 256 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.50 mm thickness: DSR 21.3.2 257 Providing and fixing ISI marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125x75x4 mm: DSR 9.95.1 258 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm: DSR 9.96.1 259 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete : 300x10 mm: DSR 9.97.1 260 Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than gradeAC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125 mm: DSR 9.100.1 261 Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.: Twin rubber stopper: DSR 9.101.2 262 Distempering with 1st quality acrylic distemper (ready mixed) of approved manufacturer, of required shade and colour complete, as per manufacturers specification.: Two or more coats on new work: DSR 13.42.1 263 Providing and fixing of expansion joint system related with floor location as per drawings and direction of Engineer-In-Charge. The joints system will be of extruded aluminum base members, self aligning / self centering arrangement and support plates etc. as per ASTM B221-02. The system shall be such that it provides floor to floor /floor to wall expansion control system for various vertical locations in load application areas that accommodates multi directional seismic movement without stress to its components. System shall consist of metal profiles with a universal aluminum base member designed to accommodate various project conditions and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self - centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. Provision of Moisture Barrier Membrane in the Joint System to have watertight joint is mandatory requirement all as per the manufactures design and as approved by Engineer -inCharge. (Material shall conform to ASTM 6063). : Floor Joint of 100 mm gap: DSR 5.44.1 264 Providing and fixing of expansion joint system related with wall joint (internal / external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System. The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall conform to ASTM 6063.): Wall Joint of 100 mm gap:DSR 5.45.1 265 Providing and fixing of expansion joint system of approved make and manufacture for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates as per ASTM B221-02. The system shall be such that it provides water tight roof to roof /roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063.) : Roof Joint of 100 mm gap : DSR 5.46.1 266 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 267 CONNECTING BRIDGE 268 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer allcomplete. DSR 10.2 269 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25 270 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture DSR 13.62 271 ROOF SKYLIGHT -18 mm THK POLYCARBONATE SHEET Supply and Installation of polycarbonate multi-layered, Multicell Xfix Connectible modular panel system for, a complete assembly of coextruded UV protected polycarbonate panels incorporated into a complete system. Standing seam polycarbonate panel system of minimum 18 mm thick (Min.) Panels with bigger width will be preferred for reducing number of joints in the roof.Panels shall be with grip lock double tooth lockingmechanism with interlocking connectible connectors running lengthwise at both sides of the panel. Panels shall be fixed on Purlins of MS tructure (will be paid Separately) with self-drilling screws and specialsTrapezoidal Heavy Duty Fastener/ Al- Cleat to ensure a pull-out load of min. 7000N (7KN) testedas per ISO 6892:1998 and IS 1608: 2005. The min width of the panel system shall be 900mm (min.). 272 Panels shall be uniform in color UV protected in combination with seven layers for required lux level, along with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels with morelayers will be preferred for better insulation and improved shading coefficient. Prices includes All accessories including Aluminum profiles with EPDM Gaskets, at alternate edges with taper cutting to achieve the required profile, aesthetics and performance criteria. U value shall not be more than 1.8 Watt/m2K as per EN ISO 1077- 2:2018 and respective third Party test certificate shall be produced before procurement. 273 Panels shall have an X cell structure also called truss bracing design to have more strength and flexibility simultaneously. Panels must satisfy Dart drop impact test as per IS 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to UV for a min. of 500 Hours as per ASTM G155.Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTM G 155. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/MS purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factoryauthorized labour with supervision to complete the entire panel installation as per drawing and direction of the engineering in charge. 274 LEVELLING 275 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 6 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. SOR 2.31 276 Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.32 277 Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. SOR 2.33 278 Felling trees of the girth (measured at a height of 1 m above ground level), including cutting of trunks and branches, removing the roots and stacking of serviceable material and disposal of unserviceable material.: Beyond 60 cm girth upto and including 120 cm girth: SOR 2.33.2 279 EXTERNALELECTRICAL 280 COMPACT SUB STATIONS - 01 (with OLTC) 281 Supply, Installation, testing and Commissioning of 11 kV / 0.415 KV Compact Sub Station(with OLTC)outdoor plinth mounted type designed for natural cooling having type tested equipment comprising distribution transformers, SF6 insulated VCB compact switchgear (RMU) having metal enclosed robotically sealed/welded stainless steel tank , L T Panel, interconnection between HT switchgear & Transformer using single core cables and Transformer to LT switchgear using Al bus bars/Cables factory built / ready for connection type, otherassociated equipment etc. complete as required conforming to detailed specification. 282 The enclosure shall have modular construction usingG.I. sheets and shall be painted with polyurethane paint from the exterior of approved shade. The enclosure for LT switchgear & HT switchgear shall be provided with IP54ingress protection. The transformer compartment will have IP23 ingress protection. Each compartment will be provided with the door and pad locking arrangement. The Compartment illumination lamp with door operated switch shall be provided for each compartment.Transformer compartment door shall be interlocked with HT breaker.The transformer used shall be specially designed for low losses and shall be hermetically sealed & with corrugated tank. 283 The L T ACB shall have inbuiltmicroprocesor based Over load protection (L), Short Circuit protection (S), Instantaneous Short Circuit protection (I), Earth Fault protection (G), Shunt Trip releases with Ics=Icu=Icw=50 KA for 1 sec, fully rated at 50 deg C ambient temperature with all standard accessories i.e. auxillary switch with 4NO + 4NC contacts, cradle, handle, safety shutter in confirmity with IS:60947 284 L T Panel BUS : 415 Volts, 3 phase 50 HZTPN high conductivity electrolytic Aluminium bus bar of suitable length, SMC / DMC supports, with colour coading and insulated by heat shrinkable sleeves and clip on shrouds for joints. The Maximum allowable temperature for the Bus bar to be restricted to 85 deg C. The temperature rise should be restricted to 35 deg C above design ambient temperature of 50 deg C. 285 The Transformer losses should confirm to IS - 1180 Part-1 (2014) efficiency Level - 2[ 1.86 KW at 50% load & 5.3 KW at 100% load shall not exceeds by 5.0% of the maximum total loss values. 286 The combination of CSS shall be as per details below:- 287 (a) Supply of 3 way 11kV ,3Phase, 50Hz, 3 wire , earthed neutral, Indoor type floor mounted, non extensible, having hinged arc proof cable doors, breaking capacity 18.4 kA,VCB Ring Main Unit enclosed in robotically laser welded stainless steel tank having IP67 degree of protection consisting of following:- 288 (i) 1 Nos. 630Amps Fault making load breaking spring assisted SF6 Ring Switches, fitted with fixed type voltage indicator device as per IEC 61958 along with associated sensor and fault passage indicator.(ii) 2 No. 630Amps tee off spring assisted type vacuum circuit breaker unit with self powered series trip microprocessor based numericalover current and Earth faultrelay for protection, fitted with fixed type voltage indicator device as per IEC 61958, along with associated sensor and fault passage indicator and ring core type protection Current transformer along with LV compartment with Ammeter with selector switches.(iii)Air Insulated Metering panel connected along with above unit , 18.4 kA , 630 amps, having Potential transformer,connected jumpers / Bus Bar, LV Compartment to incorporate Votmeter andEnergy analyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI as per the requirement (at incoming VCB) (Please refer SLD). 289 (b)1 No. 11 KV/415 V, 630 KVA three phase (with %Z is 4.5%) , 50 HZ, DYn11, +10% to -10%in 2.5% equal steps ON LOADTAP CHANGER (OLTC), oil cooled, outdoor mounting type, hermitically sealed, corrugated wall design low loss transformer with Cu winding and standard fittings.(minimum 240 Sq MM HT (E) XLPE AL cable are used for the connectivity between transformer &HT Breaker) 290 LT Bus Bars : 1000 AMP,500 Volts, 3 phase 50 HZTPN. The current density of bus bar shall not exceed1.0 sqmm / Amp 291 Neutral Bus : - Separate 2 nos 32 x 6 mm Copper insulated strip (with conductivity mim 99%) directly connected from neutral point of transformer. 292 (c )Incoming cum Outgoing - 415 VoltL.T. breaker Panel having 1000 Amp FP ACB, 50 kA fixed type, with microprocessor based O/L, E/F, S/C, Inst. S/C releases with CT/PT, ammeter with ASS, Voltmeter with VSS, PF meter, Hz meter, energy enalyser (digital type) consisting of I, V, KW, KWH, KVA, PF, HZ, MDI,phase indicating lamps, On/Offf/Trip indication. 630 KVA Compact Sub Station. 293 DIESEL GENERATING SET 294 Supply, Installation, testing and Commissioning ofSilent type Diesel Generating Set at 0.8 PF, 415 Volts, 50 cycles per second, 1500 rpm, 3 phase, suitable for parallel operation / PLC based synchronization / PLC based load manager, 0.85 load factor including circuit breaker for isolation, sound proof acoustic and weather proof enclosure, residential type silencer (as per CPCB norms-2) fabricated out of CRCA sheet of 16 SWG thickness with 9 tank pretreated before powder coating with ventillation system complete in all respects comprising of the following. 295 Diesel Engine suitable for driving alternator of above rating, compression ignition, 4 stroke cycle, Radiator cooled, turbo charged, battery starting, 1500 RPM, suitable for above output of alternator at 40oC, 50% RH & at 210 M MSL and confirming to BS 5514, BS 649, IS 10000, capable of taking 10% overloading for one hour after 12 hrs of prime continuous loading, complete with all the accessories i.e. tachometer with hour meter, flexible coupling with guard, crank case of steel, crank shaft, conncting rods, electronic governing system, dynamically balanced flywheel, air intake manifold, Air cleaner, anti vibration pads, starter motor, including all other accessories required to complete the system. 296 Instrument Panel - Engine mounted Instrument Panel fitted withand having digital display for followings : 297 Start stop switch with keyWater temperature indicationLubrication oil pressure indication.Lubrication oil temperature indication.Battery charging indicationRPM indicationOver speed indicationLow Lube oil trip indicationEngine hours indication 298 Alternator- Synchronous Alternator of above capacity at 0.8 PF, 3 phase, 415 volts, 50 cycles, 4 wire, 1500 RPM, suitable for operation at 40 deg C, 50% RH & at 210 meter above MSL, capable of taking 10% overlioading for one hour after 12 hrs of prime continuous loading, brushless, self excited, self regulated through AVR, continuous duty confirming to IS 4722, BS 2613 suitable for tropical conditions, class H insulation, including terminal box suitable for cable termination as required. 299 Note : - Alternator should have with all other accessories as per specified in Technical specfications. 300 Base Frame - Both the engine and alternator shall be mounted on suitable base frame made of MS channel which shall be installed on cement concrete foundation and vibration isolating arrangement as per recommendations of manufacturer.Inbuilt Fuel tank ofstandard capacity complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, fuel transfer system for automatic fuel refilling system with pump, piping, valves, level indicators etc. complete.Daily service Fuel tank of990 liters capacity fabricated out of 2 mm thick MS sheet complete with inlet and outlet connections, oil indication gauge, drain plug, air breather, provision for fuel transfer system,level indicators and all standard accessories etc. as required.Exhaust Silencer - Exhaust manifold with residential silencer.The D G set should be supplied with required hardware for external PLC based auto load management system.Starting system - 24 Volt DC starting system comprising of starter motors : voltage regulator and arrangement for initial excitation complete with 12/24 Volts suitable nos. lead acid type batteries of suitable AH.Ventillation System - Arrangement for fresh air intake for cooling of the engine & alternator, extraction, discharging hot air into the atmosphere as per standard specifications. 301 550 KVA 302 Supply, Fixing, testing and Commissioning of Exhaust gas piping system ofClass `B MS pipe as per IS:1239 for upto 150 mm dia and for 200 mm dia & above MS pipe as per IS:3589 with welded joints, cut to required lengths with necessary bends, fittings, flanges, painting over primer coat, with mineral wool / rock wool insulation of minimum 75mm thick of 150 Kg per cu M density on all sides of exhaust pipe, with chicken mesh wrapping and 26 SWG aluminium sheet cladding complete as required. The aluminum foil should be tightly cladded to insulation surface of pipe. The aluminum cladding shall be locked with sheet metal screws with other sections of aluminium foil.The measurement shall be doneon the basis of centre line. (Stack height should be in accordance with emission regulations of CPCB, which will gowell above the top most terrace) The exhaust piping system should be suitable for upto 550oC temperature, the surface temperature of exhaust pipe shall not exceed more than 60oC. (The rates are exclusive of support structure) (Note - Final size of exhaust pipe will beconfirmed by the DG vendor after calculating the actual back pressure and submit the same to client / consultant for approval): 300 mm dia (wall thickness - 4.85 mm) (for 625 KVA DG sets) 303 Supply & fixing of SSBellow of following diameter : 300 mm dia(for 500 KVA DG sets) 304 Supply & fabrication ofD G exhaust pipe supports by M.S angle iron of size not less than 100 x 50 mm x 6/8 mm duly grouted in the wall through minimum 8 mm thick plate and with suitable MSangle / channel iron structure. The entire MS support structure should be painted by 2 coats of anti corrosive paint over primer coat of approved shade and make. The design of support to be duly approved by the Structural Consultant / Architect before fabrication and installation. 305 FUEL PIPING 306 Providing and fixing in position the following MSpipes classC (As per IS : 1239) cut to required lenghts and installed with screwed joints including providing and fixing in position the necessary fittings like elbows, tees and reducers, sockets, MS supports and accessories including digging and refilling earth where required for buried pipes / suspended from ceiling including pipe hanger / clamped from wall including hardware complete as per site requirement.: 25 mm NB MS pipes (IS: 1239, 4.0 mm thick) 307 Providing & fixing of hand lever operated forged brass body full way ball valve type isolating valve having forged brass hard chrome plated mirror finish ball, steel handle with PVC grip, teflon seat, screwed ends tested to a pressure of 10 kg/sqcm suitable for HSD complete.:25 mm nominal bore 308 Supply, installation, testing and commissioning of Fuel Level sensor (for Low & high level) 309 MAIN LT PANEL & SUB DISTRIBUTION PANELS 310 Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings,instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete withsuitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. 311 INCOMING-800 Amp. MCCB-1 Nos.OUTGOINGS -1 nos. 200 AMPS TP MCCB. (25 KA)2 no. 100 AMPS TP MCCB. (25 KA)2 nos. 63 AMPS TP MCCB. (25 KA)1 nos. 200 AMPS TP MCCB. (25 KA) (for spare)1 nos. 100 AMPS TP MCCB. (25 KA) (for spare)1 nos. 63 AMPS TP MCCB. (25 KA) (for spare) 312 AUTOMATIC POWER FACTOR CORRECTION PANEL(CAPACITOR PANEL) 313 Supply, Installation, testing and commissioning of 14 SWG CRCA sheet steel fabricated cubical type 200 KVAR A P F C Panel consisting of 5 / 10 / 15 / 20 / 25 / 50 KVAR at 415 Volts (rated voltage of bank shall be 440 Volts) capacitor units in tier formation, housed in an integrated cubicle type automatic switching ON and OFF control panel, floor mounting, dust &vermin proof, front operated construction, enclosure class - IP 52, powder coated after proper treatment with 9 tank process with top/bottom removable gland plates, as required, double compression type cable glands, earth bus, hinged and lockable doors to achieve dust and vermin proof complete with all inter connections small wiring by min. 2.5 sq. mm. copper wires, ckt labels etc. The Aluminium Bus Bar shall be of suitable length, 500 volts, 3 phase 50 Hz TPN, electrolytic aluminium as per IS 8623All outgoings MCCBs shall be thermal-magnetic based with inbuilt O/L & S/C release.All MCCBs shall be Ics = 100% Icu, with rotary handle & pad locking arrangement, with adjustable O/L & S/C trip setting as per load requirement. All TP MCCB shall be with heavy duty solid isolable neutral link. The breaking capacity specified is Ics value. The instrument chamber shall be separate and shall comprise of flush type ammeter, voltmeter, selector switches, CTs, PTs, etc 314 Capacitor duty contactors should be used for switching individual capacitor banks.The fault withstanding capacity of panel & its control gear shall be min. 25 KA rms for 1 sec.Each section of capacitor panel shall have Verticle hood & exhaust fans for ventilation purpose.The capacitor panel shall be integrated with the main L T Panel as per schematic diagram 315 INCOMINGIncomer circuit breaker has been included in the main panel.1 set- 3 CTs , ratio 600/5A Class 1.0 accuracy 15 VA burden formetering.1Nos- (0-600A) digital Ammeter with selector switchMicro processor based automatic power factor control relay (3phase) (including power factor meter) in 9 steps for automaticcut off or add on capacitor units to keep the power factor at0.95 with variation of loads. All associated auxiliary contactors /relays shall be provided with in the scope of work.Phase indicating lamps with HRC fuses, and indicating in eachcapacitor chamber unit to indicate On/Off status of capacitorunit.BUS BARS600 AMP, 500 Volts, 3 phase 50 HZ TPN high conductivityelectrolytic Aluminium bus bar with conductivity on min 57 to58% of suitable length, SMC / DMC supports, with colourcoding and insulated by heat shrinkable sleeves and clips onshrouds for joints. The current density of bus bar shall beminimum 1.0 sq mm / amp.The Maximum allowable temperature for the Bus bar to berestricted to 85 deg C. The temperature rise should berestricted to 35 deg C above ambient temperature. 316 OUTGOINGS -2 nos. of 125 AMPS TPN 25 KA MCCB and 150 amps AC3 dutycontactor with 50 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.2 nos. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 25 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 63 AMPS TPN 25 KA MCCB and 80 amps AC3 dutycontactor with 20 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 40 AMPS TPN 25 KA MCCB and 50 amps AC3 dutycontactor with 15 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 32 AMPS TPN 25 KA MCCB and 40 amps AC3 dutycontactor with 10 KVAR heavy duty MPP type at 415 Vcapacitor bank (rated Voltage 440 Volts) , auto-manual selectorswitch, start stop push button for manual operation includingon/off indicating lamps and delay timer complete.1 no. of 16 AMPS TPN 25 KA MCCB and 20 amps AC3 dutycontactor with 5 KVAR heavy duty MPP type at 415 V capacitorbank (rated Voltage 440 Volts) , auto-manual selector switch,start stop push button for manual operation including on/offindicating lamps and delay timer complete.1 SET 200 KVAR CAPACITOR PANEL 317 Electrical Panel-1 (Block-1)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamberetc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 318 Electrical Panel-2 (Block-2)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving andmounted on non hygroscopic supports such as CMC/BMCsupport withdeteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 5 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 319 Electrical Panel-3 (Block-3)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and otherparameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 813 (E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 8 nos.40 AMP MCCB 8 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 320 Electrical Panel-4 (Block-4)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/ 812 (C)INCOMING-200 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 321 Electrical Panel-5 (Block-5)Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/813(E)INCOMING-400 Amp. MCCB-1 Nos.OUTGOINGS -100 AMP MCCB 2 nos.63 AMP MCCB 6 nos.40 AMP MCCB 6 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 322 Lighting Panel for Basement :Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018 / 811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 5 nos.63 AMP MCCB 1 no. (spare)40 AMP MCCB 1 no. (spare) 323 UPS O/G Panel:Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall beseparate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as perIS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMCsupport with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. SOR-2018/811 (C)INCOMING-100 Amp. MCCB-1 Nos.OUTGOINGS -63 AMP MCCB 2 nos.40 AMP MCCB 2 nos.40 AMP MCCB 18 no.25 AMP MCCB 18 no.40 AMP MCCB 1 no. (spare)25 AMP MCCB 1 no. (spare) 324 CO2 Gas Flooding System For Main LT PanelSupply, installation, testing and commissioning of Polymer Tube Detection based CO2 Gas Flooding System For Main LT Panel, Consisting of the following components: CO2 Cylinder, 4.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 325 CO2 Cylinder, 2.5 kg capacity, complete with all necessary CO2 Gas, fittings, support and accessories, connected with Valve (with manual release facility). 326 Filling adopter 327 D/I Adopter for converting the indirect valve to function as Direct System. 328 FET End of Line adapter with Pressure gauge for Automatic fireuppression tube used for fitting at the end of the tube for pressurizing and re pressurizing the tube. Fitting made by brass (plated / unplated), Stainless steel, Elastomeric Sealings, Copper Nickle plated, Temperature range TS -20 Deg C till + 60 Deg C, Maximum working pressure 25 Bars, made as per PED Pressure Equipment Directives. 329 Pressure Switch to monitor Pressure drop in the tube, switchpoint 11 Bars. 330 Flexible Polymer Detection Tube made by special modified Polyamide (PA), Color Red, High grade quality, UV Stabilized, Inner diameter 4mm, Outer Diameter 6 MM, Melting Point approx. 220 degrees Celsius when heating up with 10 K/minute, Steady load tested upto max. 80° C. The lowest operating temperature is stipulated at minus 40°C. Service Pressure 20 Bar, Burst Pressure at 20 Deg C approx 120 Bars, Release Temperature : Rapid heat increase in temperature at 20 bars pressure approx 150 Deg to 180 Deg C (Without Flame) 331 Master Control Unit for connecting each system with electronic hooters and productivity input to Scada /Fire Alarm system including all necessaries +electrical wiring to make each entire system functional.(Indeginous) 332 Containing all required fitting and fixing 333 Installation & Commissioning Charges includes complete setup of the system, Installation of Cylinders on specially designed brackets, Laying of sensor tubes using tube attachments and Cable ties, fixing end of line plugs and end of line adapters, pressurizing tube @ 15-18 Bars using Nitrogen pressurizingagent. 334 Supplying and fixing and connection of the following rating, four Pole MCCB (25 KA), 415 volts, at the incomer / outgoing in seperate enclosure, complete with connections, testing and commissioning etc. as required : 100 AMP FP MCCB (25 KA) micro processor based. 335 (VI) INVERTORSupply, installation, testing and commissioning of on lineUPS with builtin parallal redundancy, as per following detailsTechnology : Micro processor based controls, True on line,Double conversion type, should have cold start facility.Input :- (mains / local D G set compatibility)a) Voltage : 415 V / 3 Phaseb) Voltage Variation : - 20% to + 20%c) Input Frequency : 50 Hz.d) Frequency Variation : + 10%e) Automatic phase sequence correction facilityOutput :-a) Voltage : 230 V / 1 Phase, 415 V / 3 Phaseb) Voltage Variation : + 1%c) Frequency Variation : 50 Hz. + 0.1%Overall Efficiency : > 90%Charger : Should have built in charger to suit systemrequirement.Battery type : Sealed Maintenance Free - SMF (Global Yuasa /Exide)Battery Backup = 15 min.External battery backup will be usedDisplay : Should have LCD display with event logging facility.Upgradeability : Should be upgradeable to work as parallelredundant UPS in load sharing mode.Software Communication : Should have SNMP (Simple NetworkManagement Protocol) compatibilityRating : 30 KVA 336 SUB-HEAD - 1 : S/F MODULAR TYPE SWITCH / SOCKET & SUBMAINS 337 Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required.DSR 1.57 338 Wiring for circuit/ submain wiring along with earth wire with thefollowing sizes of FRLS PVC insulated copper conductor, singlecore cable in surface/ recessed medium class PVC conduit asrequired. DSR 1.14 339 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (DSR 1.14.4) 340 2 X 16 sq. mm + 1 X 6 sq. mm earth wire(DSR 1.14.6) 341 4 X 6 sq. mm + 2 X 6 sq. mm earth wire(DSR 1.14.9) 342 4 X 10 sq. mm + 2X6 sq. mm earth wire(DSR 1.14.10) 343 SUB-HEAD - 2 : DISTRIBUTION BOARDS & CIRCUIT BREAKERS 344 S/F of surface / flush mounting SPN Distribution board with additional metal door without MCB complete in all respects as directed at site by Engineer-in-charge. a) 12 WAYS CAT A (UPSOR 1025(A) 345 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. (a) 4 WAYS CAT A (UPSOR 1026 (A) 346 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. 6 WAYS : CAT A (UPSOR 1027(A) 347 S/F of surface/flush mounting TPN distribution board with additional metal door without MCB complete in all respect as directed at site by Engineer-in-charge.. : 8 WAYS: CAT A (UPSOR UPSOR 1028(A) 348 Supply & fixing of 6/10/16/20/25/32 amp. SP MCB (10 KA) : CAT A(UPSOR 1002 349 Supply & fixing of 63 Amp DP MCB (10 KA) :CAT A : UPSOR 1011 350 S/F of 63 amp FP MCB (10 K.A.) :CAT A : UPSOR 1020 (A) 351 S&F and making connection of 63A 2 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge.UPSOR 394 352 S&F and making connection of 63 Amp. 4 pole 30mA ELCB/RCCB of Din Rail Mounting complete in all respect as per direction and satisfaction to the Engineer in charge. UPSOR 398 353 Supply and fixing danger board fabricated from 10 gauge M.S. Sheet as per I.E. Rules. UPSOR 1109 354 S&F single pole MCB blanking plate UPSOR 1034(B) 355 SUPPLY AND LAYING OF CABLES & ACCESSORIES 356 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor byclamps etc UPSOR (501) 357 6 sqmm 3 core 358 10 sqmm 4 core 359 16 sqmm 4 core 360 25 sqmm 3 1/2 core 361 35 sqmm 3 1/2 core 362 50 sqmm 3 1/2 core 363 95 sqmm 3 1/2 core 364 120 sqmm 3 1/2 core 365 150 sqmm 3 1/2 core 366 185 sqmm 3 1/2 core 367 240 sqmm 3 1/2 core 368 300 sqmm 3 1/2 core 369 deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required. 370 Supply fixing of plam or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections etc. complete in all respects as per direction of Engineer-in-charge (UP SOR 504) 371 6 sqmm 372 10 sqmm 373 16 sqmm 374 25 sqmm 375 35 sqmm 376 50 sqmm 377 70 sqmm 378 95 sqmm 379 120 sqmm 380 150 sqmm 381 185 sqmm 382 240 sqmm 383 300 sqmm 384 Supply and fixing brass nickle plated compression glands for PVC insulated armoured, served, sheathed cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth conductor UPSOR 503 385 6 sqmm 3 core 386 10 sqmm 4 core 387 16 sqmm 4 core 388 25 sqmm 3 1/2 core 389 35 sqmm 3 1/2 core 390 50 sqmm 3 1/2 core 391 95 sqmm 3 1/2 core 392 120 sqmm 3 1/2 core 393 150 sqmm 3 1/2 core 394 185 sqmm 3 1/2 core 395 240 sqmm 3 1/2 core 396 300 sqmm 3 1/2 core 397 Supply of ISI marked Copper conductor PVC insulated cable as per IS 1554 armoured, served, sheathed 1100 volts grade. : 25 sqmm 1 core 398 Laying and testing of aluminium / copper conductor cable PVC / XLPE insulated armoured, served, sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray or inside existing RCC / HDPE DWC pipe complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) / end terminations to the cable leads, insulating with tape and making connections with brass / nickle plated flame proof double compression glands, providing cable tags complete in all respect upto the satisfaction of Engineer-incharge. (The supply of terminations and glands shall be under seperate item): (a) 25 sqmm 1 core 399 Supply and laying of ISI marked Copper conductor PVC insulated control cable as per IS 1554 PVC sheathed 1100 volts grade. On surface the cable run shall be fixed by GI clamps etc. of suitable size or on existing cable tray complete in all respect .The armouring of the cable shall be properly connected with the earth conductor including fixing of palm or pin type copper tin plated cable socket (lug) to the cable leads, insulating with tape and making connections complete in all respect including end termination, double compression glands, supply of clamps, lugs, tape etc complete upto the satisfaction of Engineer-incharge. Armoured 400 6 x 2.5 sq mm armoured (DG to Main LT panel interfacing) 401 12 x 2.5 sq mm armoured (2 runs DG controlling) 402 12 x 2.5 sq mm armoured ( For Transformer contro wiring) 403 2 x 4 sq mm armoured (for Battery charging) 404 Supply of 3 core stranded aluminium conductor 11 KV grade XLPE (E) (Cross linked Polyethylene) insulated PVC bedded, Galvanised flat steel strip armoured cable confirming to IS : 7098 (part II with latest amendments) a) 240 sq. mm 3 core 405 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of grade exceeding 1.1 KV but not exceeding 11 KV of following size in the existing masonry open duct etc. as required.a) Size exceeding 120 sq. mm. But not exceeding 400 sq. mm. 406 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 407 Supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories includinglugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required. a) 240 sq. mm 3 core 408 CABLE TRAY 409 Supply and erection of Perforated type cable trays made out of prefabricated Galvanized sheet steel including tees, bends, crossings, reducers, couplings to be laid in cable trenches or installed over head on wall or hanged from ceiling including all neccessary supports, brackets at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts & bolts complete in all respects.: The support for 1000mm, 900 mm and 750 mm wide cable tray will be by 50 x 50 x 6 mm MS angle, for 600mm and 450 mm wide cable tray will be by 40 x 40 x 5 mm MS angle, for 300mmwide cable tray will be by 32 x 32 x 5 mm MS angle, for 150mmwide cable tray will be by 25 x 25 x 4 mm MS angle. 410 900 mm (W) X 50 mm (H) X 2 mm (T) 411 750 mm (W) X 50 mm (H) X 2 mm (T) 412 600 mm (W) X 50 mm (H) X 2 mm (T) 413 450 mm (W) X 50 mm (H) X 2 mm (T) 414 300 mm (W) X 35 mm (H) X 1.5 mm (T) 415 150 mm (W) X 35 mm (H) X 1.5 mm (T) 416 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplersetc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.. 417 90 mm dia (OD-90 mm & ID-76 mm nominal) (DSR 14.16.2) 418 160 mm dia (OD-160 mm & ID-135 mm nominal) DSR 14.16.4) 419 MISCELLANEOUS ITEMS EXTERNAL ELECTRICAL 420 Providing and fixing M.V. danger notice plate of 200 mm x 150 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.21) 421 Providing and fixing H.V. danger notice plate of 250 mm x 200 mm made of mild steel, 2 mm thick and vitreous enamelled painting white on both sides, and with inscription in single red colour on front side as required . DSR 2.22 422 S/F of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M) UPSOR 1134 423 Supply and fixing of Fist aid box as approved by Indian red cross conforming to IS : 2217. 424 Supply of rubber gloves of 11 KV grade as per IS : 4770. 425 Supply and fixing of cable route maker as directed by Engg-incharge. UPSOR 505 426 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality. to withstand 30 KV dielectric strength as per IS 15652 complete in all respects. (For LT Panels) UPSOR 1136 427 Supply and laying of 1800 mm x 900 mm x 20 mm thick chequered rubber matting of tested quality to withstand 45 KV dielectric strength as per IS 15652 complete in all respects. (For 11 KV Panels) UPSOR 1136 428 Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc. as required.a) 300 mm dia. DSR 14.14.4 429 Supply and erection of pregalvanized Ladder type cable trays made out 25mm x 75mm x 25mm x 2.5mm GI Section all along (as runner) and 20mm x 30mm x 20mm x 2.5 mm GI Section (as rungs) at every 250mm interval c/c including tees, bends, crossings, reducers, couplings to be laid over head on wall or hanged from ceiling including all neccessary supports, brackets (50x50x6 MS Angle) at every 1500 mm c/c, grouting, levelling, suspention and fixing arrangements, dash fastners, G.I. nuts &bolts complete in all respects. 430 900 mm (W) X 75 mm (H) 431 750 mm (W) X 75 mm (H) 432 EARTHING 433 BODY / SAFETY EARTHING (FOR BODY OF ALL ELECTRICAL EQUIPMENTS LIKE RISING MAINS, TRANSFORMER, DG SETS,LIFTS ETC. 434 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound. (borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6 mm. Further GI strips from equipments shall be connected to Copper strips by means of special bi-matellic connector (i.e. stainless steel). please refer submitted drawing. 435 Providing & fixing 25mm x 5mm G.I. strip on surface, in recess or in ground including connections etc. as required (LT Panel,Cable Trays & Elevator). DSR 5.15 436 Providing & fixing 32mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (Pig tail) UPSOR 717 437 Providing & fixing 50mm x 6mm G.I. strip on surface, in recess or in ground including connections etc. as required (SubstationGrid) 438 NEUTRAL EARTHING 439 Maintenance Free Earting : - Supply of Low carbon high tensile Copper Bonded Ground rods having min 250 micron of copper coating . The diameter of Rod should be 19 mm with the length of 3000 mm . The ground rod should be UL approved and tested from CPRI. The earthing include 400 mm square C.I. frame with hinged cover, masonry housing including excavation and back filling.The Rod should be surrounded with Earth Enhance compound of 25 Kg tested as per IEC 62561-2 for the rod & IEC 62561 -7 for compound.(borh are of same manufacturer) Exothermic welding shall be used for connection between main electrode (copper bonded rod) and copper strip of size 32 x 6mm. please refer submitted drawing. 440 Providing & fixing 32mm x 6mm insulated Copper strip on surface, in recess or in ground including connections etc. asrequired. 441 SOLAR PLANT 442 ON-Line Solar Photovoltaic system plant including suitable rating Poly crystalline Silicon PV Modules having a efficiency of minimum 15% (without any power export arrangement), String combiner box, DC Distribution board etc. complete as required. Scope of work also includes supply, installation of GI structure, (80 micron) in suitable section complete with all accessories and hardware including civil work as required at site for mounting PV panels.: 15 kWp SET 170 415 V, 3 phase, 50 Hz AC power string inverter (Grid intractive) with stand & all protection and controls having overall efficeiency of not less than 95%. : 15 kWp (nominal) SET 171 AC distribution board made of 2 mm CRCA sheet, power coated having IP55 degree of protection (for indoor installation) for terminating 415 V, 3 phase, 50 Hz power suppled from inverter complete height with following multifunction: - Digital multifunction meter (EM 6400 of Schnieder or equal) - 40 Amp TPN MCB (10 KA) - Phase indicating lamps. SET 1Lighting Arrestor SET 1Surge Protector SET 1 443 STREET / EXTERNAL LIGHTING 444 Supply & fixing of 20 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 410 mm base plate 32 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.(UPSOR 653) 445 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for 170 to 200 Watt. Confirming to IP 66 protection complete in all respect.Category AAA (UPSOR 1455) 446 Supply and fixingof LED Street light Fitting having die cast aluminium body and diffuserwith driver set suitable for 45 watt to 50 Watt. Confirmingto IP 65 and above protectioncomplete in all respect.Category AAA (UPSOR 1443) 447 Supply and fixingof 3 Watt LED Path / Walkover luminaire having powder cotated die cast aluminiumbody with drive set . Confirming to IP 65 and above Protection complete in all respect.Category AAA (UPSOR) MR 448 Supply and fixingof 3 Watt to 4 Watt LED Spot/Spike light Confirming to IP 65 and above Protection complete in all respect. Category AAA (UPSOR 1441) 449 Supply and fixing of decorative 8 to 16 Watt LED bollard luminaire with driver set confirming to IP 65 and above protection complete in all respect.Category AAA 450 Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation,excavation & back filling and Required T&P completee in all respect. 451 Supply installation, testing and commissioning of 3x2.5 sqmm flexible fire retardant copper connecting wire of required length from MCB in cable junction box of pole to luminaire along with MCB & Connector complete as required. 452 Supply & burrying of 40 mm dia x 4.50 m long G.I. pipe vertically for earthing having 12 mm dia holes spaced 75 mm apart drilled upto 2 meter brom the bottom complete with one earthing lead of no. 6 to 8 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switchboard (from apron to switch board the cost of GI pipe & GI wire will be extra), 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect. 453 Supply & burrying of 600mm x 600 mm x 6.0 mm G.I. plate, vertically for pole earthing with its top at least 3 m below ground level complete 20mm dia. G. I. pipe and funnel for watering and one earthing lead of no. 8 to 10 SWG G.I.wire in 15 mm dia. GI pipe upto switch board (from apron to switch mm dia. GI pipe upto switch board (from apron to switch board the cost of GI pipe & GI wire will be extra) 300 mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . 454 Supplying & Laying of one number 8 SWG G. I. wire in 15 mm. dia. G. I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P and other material required for proper completion of the work as directed at site. 455 Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. 456 INCOMER : 457 f (ii) 40 AMP TPN MCB (10 KA) 458 e (ii) 25 AMP TPN MCB (10 KA) 459 OUT GOINGS : 460 4 nos. 6-32 AMP DP MCB (10 KA) 461 24 nos. 6-32 AMP DP MCB (10 KA) 462 Supply of ISI marked aluminium conductor XLPE insulated cable as per IS 7098, armoured, served, sheathed 1100 volts grade. 10 sqmm 3 core 463 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Size not exceeding 35 sq. mm. 464 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation and refilling the trench etc. as required, but excluding sand cushioning and protective covering. Size not exceeding 35 sq. mm. 465 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe etc. as required. Size not exceeding 35 sq. mm. 466 Supply and laying of ISI marked aluminium conductor PVC / XLPE insulated armoured, served, sheathed cable 1100 volts grade at 750 mm below ground level over a cushion of 75 mm thick sand around & protected with brick on sides & top on surface the cable run shall be fixed on M.S. clamps etc. of suitable size complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. e) 6 sqmm 3 core 467 Deduct in above item when cables is passed through G.I/M.S. or Hume pipe in road crossing or along the wall.The cost of the G.I. pipe,hume pipe is to be extra when and where required.
Contract Date: Ref. Documents Contract Value : Ref. Document
Local Bodies No of Bidders 3
Uttar Pradesh View Result →
TenderDetail
Loading tenders