BRR : 12126868
Click Here To View Tendering Authority. Price Bid City/State :  Coimbatore, Tamil Nadu
Tender Brief : Tender For Purchase Of Equipment , 1. Electrochemical Workstation , General Requirements -  Research-Grade Modular Electrochemical Workstation Suitable For Corrosion, Energy Storage, Sensors, And Material Research Applications., System Shall Support Potentiostatic, Galvanostatic, And Electrochemical Impedance Spectroscopy (Eis) Techniques In A Single Integrated Platform, Modular And Upgradeable Architecture With Capability For At Least Two Independently Operating Channels.  Suitable For Low-Noise, High-Precision Electrochemical Measurements Over Long-Duration Experiments.,Ii) Potentiostat... Read More
Tender Value
₹ Ref. Document
Submission Date
24-08-2026
Participated Bidder List
2 No of Bidder(s)
Sr No. Bidder Name Bid Analytics Technical Bid Financial Bid AOC Bid Value Rank
1 cnet-technologies Bid Analytics
2 cnet-technologies Bid Analytics 16,80,000 L1
Work Detail
tender for purchase of equipment , 1. electrochemical workstation , general requirements -  research-grade modular electrochemical workstation suitable for corrosion, energy storage, sensors, and material research applications., system shall support potentiostatic, galvanostatic, and electrochemical impedance spectroscopy (eis) techniques in a single integrated platform, modular and upgradeable architecture with capability for at least two independently operating channels.  suitable for low-noise, high-precision electrochemical measurements over long-duration experiments.,ii) potentiostat / galvanostat performance -  applied potential range : ± 10 v or better , compliance voltage : ± 12 v or better,, current range : from pa/na level upto at least ±1 a or higher , current resolution : ≤ 1 pa (best range),, voltage resolution : ≤ 1 μv,  high stability, low drift, low-noise electronics suitable for research-grade measurements\, automatic and manual ir compensation facility, iii) electrochemical impedance spectroscopy (eis) -  frequency range : 10 μhz to 5 mhz or wider , high precision ac excitation control in millivolt range,  support for equivalent circuit fitting and impedance modeling , high signal-to-noise ratio with reliable phase accuracy, iv) measurement techniques - the system shall support the following electrochemical techniques:  cv, lsv, ca, cp, ocv, sv , dpv, swv, npv, rnpv, dnpv, dpa, ocp measurement, battery testing (gcd or gcpl), eis and related impedance analysis techniques, v) software - fully integrated electrochemical control and analysis software , real-time data acquisition and graphical display  multi-channel experiment control with automation capability, advanced eis analysis with all curve fitting tools,  data export in standard formats (csv, txt, excel-compatible), perpetual or lifetime software license preferred,  scripting or programmable experiment capability desirable, general electrochemistry peak analysis, n fit etc, vi) computer system - desktop computer compatible with instrument software, processor : intel core i5 or higher (latest generation or equivalent),  ram : ≥ 8 gb, storage : ≥ 1 tb ssd, monitor : ≥ 21-inch led display, operating system: licensed windows 10/11 professional - keyboard and optical mouse, vii) power backup -  online ups, capacity sufficient to support complete system (instrument + computer), minimum backup time: 30 minutes at full load, surge protection and automatic voltage regulation included, viii) safety and instrument protection -  built-in over-voltage, over-current, and short-circuit protection,  electrochemical cell protection against abnormal load conditions,  proper grounding and shielding for low-current measurements,  fully enclosed system with no exposed live electrical parts, compliance with relevant electrical safety standards (iec/ce or equivalent), ix) accessories and installation -  all required cables, connectors, and interface modules shall be included,  two standard electrochemical cell kit (including reference electrodes, counter electrodes, glass electrodes, clips-extra and dummy cell) compatible with three-electrode configuration shall be provided,  installation, commissioning, and on-site training to be provided by supplier,  calibration certificates and user manuals shall be supplied , two-year comprehensive warranty x) as applicable,  expandable multi-channel configuration beyond two channels,  integrated temperature control capability for electrochemical cell  remote operation and network-based control capability,  advanced corrosion analysis modules, xi) environmental conditions,  a suitable air-conditioning system with stabilizer shall be provided to maintain stable laboratory conditions for instrument operation, the system shall support continuous 24×7 operation. warranty: two years, delivery: 4-6 weeks
View Original Notice/Document
Result Documents
Tender Documents
Download File Name File Description
Download 2a0c3f50-0809-4a7f-80f0-36e57e7a83a4 financialevaluation notice
Download boqcomparativechart document
Download boqcomparativechart document
Download boqcomparativechart document
Download finsummary_829280 document
Download boqcomparativechart document
Download finsummary_829280 document
Download techsummary_829280 document
Download File Name File Description
Download 844d79dc-2129-4213-b6ab-f3a2f689b00c Tender Documents
Download BOQ_829280 Tender Documents
Download Tendernotice_1 (10) Tender Documents
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

Financial Evaluation In Progress

Financial bids are currently under review. Awarded bidder information will be published after final evaluation.

PriceBid
Similar Tenders Results
TenderDetail
Loading tenders