View Bid Results For Amc Of Split Air Condition Tenders

We found 26 Bid Results related to amc of split air condition tenders. You can find Contractor details who won amc of split air condition tenders along with contract details in Bid awards announcements section.

Filters
Stage
19
5
2
Tender Publishing Platform
1
25
State / UT
10
6
6
5
3
1
1
1
1
1
1
Contract Value
10
4
9
3
Publish Date
0
0
0
0
0
Sector
9
8
6
3
3
2
1
1
1
1
Ownership
5
15
5
4
1
1
Within keyword
Active filters:
Showing 1–1 of 26 tenders matching your filters
2.
Power #11055259 AOC
Tender Document For Sub-Station and Transmission Line [PACKAGE-C8(1B)]-TECHNICALSPECIFICATION FOR 12kV, 800A, 18.4kA, MULTI PANEL (Incoming, Bus Coupler with Adaptor Panel and Outgoing) SHUNT TRIP, INDOOR TYPE SCADA COMPATIBLE SWITCHGEAR WITH MOTOR OPERATED SPRING CLOSING VACUUM CIRCUIT BREAKER- 1 ELECTRICAL PART : 2 WBSETCL Assessed Quantities: 3 245KV 40KA for 3sec Gas Insulated Switchgear - i)2500 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker for line and Transformers & 2500A for Bus coupler Bay iv) CT with current ratio 1600-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification v) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc. vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 4 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 5 LA for Line bay ( one number per phase - to be installed within GIS) 6 CompleteTransformer Bays 7 Buscoupler Bay 8 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 9 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 10 Portable UHF PD monitoring System - The analyser shall have 6 channel input withinherent PD location accuracy of 0.5m., colour display unit and user friendly interface for detailed analysis.The system includes allaccessoriesto monitorPD, UHF cables,required software and other accessories to complete as per Technical Specification. 11 Dew Point Meter as per Technical Specification 12 145KV 31.5KA for 3sec Gas Insulated Switchgear i)2000 A rated Double Bus Barwith BUS earthing arrangement ii) 3 phase / single phase encapsulated iii) Minimum 2000 A rated Circuit Breaker iv) Each feeder comprises of Circuit Breaker, Disconnectors, CTs, Bus bar, density monitors, gas partition etc.v) CT with current ratio 1000-800-400/1A (5 core) for feeder & transformer & 2000-1600/1A (3 core) for bus coupler as per CT specification vi) suitable for EHV cable entry withdouble terminationarrangementif single Run cable is used other will be kept as spare. vii) Standalone Local Control Cubicle (LCC) with all required accessoriesand Gas monitoring system and the requiredPD sensors to cover the total GIS portion. -The complete system shall be as per technical specification and requirement comprising of - 13 Complete LineBayswith accommodation of3 nos GIS Line VTeach having 3 cores(2 nos core for Protection and 1 no core for metering and other parameters as per technical specification 14 Complete Transformer Bays for LV side of 160 MVA 220/132 KV Transformer & HV side of 50 MVA 132/33 KV Transformers 15 Bus coupler Bay 16 Disconnector with earthing arrangement and gas tight barriers atOne side of Main Bus I & IIfor future extension.one side 17 2 sets of 3 phase Bus PT each having 3 cores (2 core Protection and 1 core Metering), each for Main Bus-I & Main Bus-II with disconnectors & earth switch. As per Tech Spec 18 36 KV, 31.5KA for 3sec Indoor, floor mounted drawoutSwitchgear Assembly (2500A Bus rating with Copper Bus Bar) with VCB suitable for EHV cable entry withtripple termination arrangement and bus earthing arrangement from both side, Line earthing arrangement and dead line status and corresponding electrical and mechanicalinterlocking arrangementas per technical specification and requirement comprising of - 19 Outgoing Feeder Bays, 1250A Circuit Breaker ratingas per Techspec. 20 LV side of50MVA 132/33KV Transformer Bays (2000 A Breaker Capacity) CT Ratio 2000-1000/1A 3 coreas per Tech spec 21 HV side of6.3 MVA 33/11KV Transformer Bays(1250 A Breaker Capacity ) as per Tech Spec 22 Station service transformer bay (1250A Circuit Breaker rating) 23 Bus section Bay (2500 A Breaker Capacity) 24 (i)2(two) set of 3 phase Bus PT - 5 limb, (One set each for Main Bus-I & Main Bus-II) with isolation arrangement.as per Tech Spec. (ii) Other required equipment & accessories like Bus Earthing arrangement etc. to complete the system . 25 12 KV, 1600 A, 25 KA, 30 V DC, SCADA compatible, VCB Switchgear includingProtection Relays, ,control & annunciation equipment and other accessories complete as per technical specification (uploaded for Nandanpuronly) Cable and bus earthing shall be electrically and mechanically interlocked with associated breaker as per interlock requirement. but rating should be as per BOQrequirement comprising of - 26 Outgoing Line Bays (CT Ratio 400-200/1) 2 coreVCB rating 1250A 27 Incoming Transformer Bays(CT Ratio 600-400/1A) 4 core VCB rating 1250A 28 Bus section Bay VCB rating 1600A 29 (i) 3(Three) set of 3 phase Bus PTwith isolation arrangement must be mounted above incomer switchgearpanel. (ii) Other required equipment and accessories like Bus earthing arrangement etc to complete the system 30 Electric Overhead Travelling Crane (E.O.T.) 31 Electric Overhead Travelling Crane (E.O.T.)- For 220 KV GIS Building 5.0 Metric Ton capacity or maximum weight of GIS shipping unit whichever is higher -complete with all accessories as per technical specification and requirement. 32 Transformers : 33 160 MVA, 220/132/33 KV, 3 Phase ,Auto Transformer suitablefor NIFPSwith Bushing CTs and NCTS andRTCC panel alonwith BCUand other accessories as per technical specification ofAuto Transformer. 220KV & 132KV bushingshall be of RIP/RIS type. 34 Nitrogen injection type Fire Prevention and ExtinguishingSystem including reservoir tank andall required accessories for 160 MVA, 220/132/33 KV, 3 Phase Power Transformer 35 50 MVA, 132/33 KV, 3 Phase, 2 winding Power Transformerwith Bushing CTs and NCTsincluding RTCC panel alongwith BCU and alongwith all accessoriesin line with technical specification of Power Transformer.132 KVbushingshall be of RIP/RIS type. 36 6.3 MVA, 33/11 KV, 3 Phase, 2 winding Power Transformer with Bushing CTs and NCTs in line with technical specification of Power Transformer . As per Tech spec 37 STATION SERVICE TRANSFORMER: 315 KVA, 33/0.415 KV, 3Ph, 2-Windingas per technical specification andrequirement 38 EARTHINGTRANSFORMER: 33KV, 3 Ph ,fault current rating of874 Amp for 30 secas per Technical Specification and requirement 39 Isolators : As per Technical specification 40 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITHOUT EARTHING SWITCH (excluding insulators) for HV side of 160 MVA Transformers(water proof mechanism housing with auxiliary switch) 41 Solid Core Insulator for each set of above Isolators 42 220 KV, 1600A, 40 KA for 3sec, HCB, motor operated 3-phase Assembly WITH EARTHING SWITCH (excluding insulators) for Line bay(water proof mechanism housing with auxiliary switch) 43 Solid Core Insulator for each set of above Isolators 44 132KV, 1250 A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with Earth Switch for line feeder, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 45 Solid coreInsulator for each set of above Isolators 46 132KV, 1250A,31.5 KA for 3sec, HCB, 3Ph Assembly isolator with out Earth Switch for Transformers, motor control - excluding solid core insulators as per Tech. Specification (water proof mechanism housing with auxiliary switch) 47 Solid coreInsulator for each set of above Isolators 48 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - forHV side of 33/11KV Transformer & Earthing Transformer(excludingInsulators ) 49 Solid coreInsulator for each set of above Isolators 50 33KV, 2000 A,31.5 KA for 3sec, CRDB, 3Ph Assemblywithout earthswitch as per Tech. Specification - for LV side of 132/33 KV Transformer,(excludingInsulators ) 51 Solid coreInsulator for each set of above Isolators 52 33KV, 1250A,31.5 KA for 3sec, CRDB, 3Ph Assembly with Horn-gap fuse units to be mounted on same structure of isolator ( for Station service Transformers ) as per Tech. Specification(excluding insulator) 53 Solid Core Insulator for each set of above Isolators 54 LIGHTNINGARRESTORAs per Technical specification 55 198 KV, single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos. 160 MVA Transformersas per technical specification and as per requirement. (Polymer type) 56 198 KV class polymer type LA at Composite Tower 57 120 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless for 2 nos 160MVA Transformers,2 nos 50MVA Transformerand line bays (Polymer type) 58 42 KV, Single phase, 10 KA, Heavy Duty, Station Class, Gapless (for 2 nos 50MVA transformer, 3 Nos 6.3 MVA 33/11 KV Transformer &2 nos.315KVA station serviceTransformer) ((Polymer type) 59 12 KV, 3 phase 10KA,Station class GapelessLA (LV side of 3nos. 6.3MVA Transformers) (Polymer type) 60 220 V Battery & Charger( As per technical Specification ) 61 VRLA Battery SET - 800AH 220 Voltas per Tech Spec. 62 Battery Health monitoring system forabovementioned 220V batteries as per Technical Specification. 63 Battery Charger - 220Volt. suitable for above Battery set in line with Technical Specification(Float Charger capacity - 80A and Float cum Boost Charger capacity - 150A) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also. 64 VRLA BATTERY SET -75 AH 30 VoltCapacity will be as per design or75 AH whichever is higher as per uploadedtech spec 65 Battery Charger - 30Volt. Foalt cum Boost Charger Float charger capacity 35A or as per design whichever is higher as per Tech Spec ( uploaded) - Charger shall be equipped with disconnecting arrangement forLoad and Battery - Charger shall be capable of charging the battery both in Constant Current and Constant Voltage mode with appropriate selector switch - Fuse fail indication arrangements are to be provided for all fuse units. All the indications like fuse fail, blocking diode fail, rect. fail, battery earth fault, charger fail etc are to be provided locally, as well as necessary potential free contacts to send at remote end also.(as per uploaded spec.) as per uploaded spec 66 PROTECTION PANEL ( SIMPLEX REAR Open Door type ) inclusive of all relays, Annunciator (Minimum 24 windows or more as per scheme requirement, with RS485 port for Modbus Communication, Auxiliary AC and DC Supply as well as Dedicated AC Fail and DC Fail windows) at each panel and other accessories as per specificaction and requirement. (Protection Panels will be installed in Relay Room.) 67 Protection panel with BCU and Breaker Control Switch for 220 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 68 Protection Panel with BCU and Breaker Control Switch for 220 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, Circulating Curent Protection Relay in addition to all other Transformer HV Protection relays are to be considered in HV side Panel). 69 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 220 KV Bus Coupler complete as per Tech. Spec. 70 220 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 71 Protection panel with BCU and Breaker Control Switch for 132 KV Line Feeder. Each feeder panel will have 2 nos. Distance Protection Relays of different manufacturer having different model, algorithm, hardware with Group Selection Switch and all other accessories complete as per Tech. Spec. 72 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 220/132/33 KV Transformer complete as per Tech. Spec. 73 Protection Panel with BCU and Breaker Control Switch for 132 KV side of 132/33 KV Transformer complete as per Tech. Spec. (Transformer Differential Relay, HV REF Protection Relay in addition to other Transformer HV Protection relays are to be considered in HV side Panel) 74 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both Bus PTs) and Breaker Control Switch for 132 KV Bus Coupler complete as per Tech. Spec. 75 132 KV Busbar Differential Panel with low impedance type Centralized Busbar Protection Relay having in-built LBB protection, End Fault protection, CT Open Detection feature etc. complete as per Tech. Spec. (Panel to be complete with all relays, components and wiring i.r.o. at least 3 nos. future Line bays and 1 no. future Transformer HV bay in addition to present bays) 76 Protection Panel with BCU and Breaker Control Switch for 33 KV Line Feeder as per Tech. Spec. 77 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/0.415 KV Station Service Transformer (S.S.T.) as per Tech. Spec. Panel schematics will be similar to Line Feeder Panel, along with addtitional S.S.T. Supervision Relays. 78 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 132/33 KV Transformer as per Tech. Spec. 79 Protection Panel with BCU and Breaker Control Switch for 33 KV side of 33/11 KV Transformer (considering HV REF Protection Relay, HV Over-current Relay and all other accessories alongwith space and provision for future Transformer Differential Relay) as per Tech. Spec. and actual requirement. 80 Protection Panel with BCU (having 2 set voltage coils for measuring 3-phase bus voltages from both side Bus PTs) and Breaker Control Switch for 33 KV Bus Section bay as per Tech. Spec. 81 Meter Panel without meter( As per drawing uploaded) 82 XLPE Copper Cableas per Technical Specification 83 220 KV 630 Sq. mm single Core Copper Cable AL sheath forLine from Composite Tower To GIS- Single phase connection with double run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 84 220 KV 630 Sq. mm single Core Copper Cable AL Sheath for HV side of 160 MVA TransformersSingle phase connection with single run cable for each phase- The actual length will be decided after finalisation of LUP drawing. 85 220 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) forLine bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 86 132 KV 630 Sq. mmsingle core Cu cable AL sheath (as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 160 MVA, 220/132/33 KV Transformers - Single phase connection with doublerun cable for each phase - The actual length will be decided after finalisation of LUP drawing. 87 132 KV 400 Sq. mm Single Core Cu cable AL sheath(as per technical specification and as per requirement) for connection of 132 KV side of 2 nos 50MVA, 132/33 KV Transformers and Line bays- Single phase connection with single run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 88 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer - Single phase connection with double run cable for each phase - The actual length will be decided after finalisation of LUP drawing. 89 33 KV 240 Sq.mmThree Core copper cable for three 33/11KV 6.3MVA Transformer , two 315KVA Transformer - Three Phase Connection with single run cable - The actual length will be decided after finalisation of LUP drawing. 90 11 KV 400 Sq.mm 3 coreCopper for 33/11KV 6.3MVA Transformer - Three Phase Connection with singlerun cable - The actual length will be decided after finalisation of LUP drawing. 91 Outdoor End Termination Kit/ cable sealing end and other required accessories for above XLPE cables as per requirement and specification : 92 For 220KV 630 Sq.mmsingle core copper cable for Line 93 For 220KV 630 Sq.mmsingle core copper cable forTransformer 94 For 220KV 400 Sq.mmsingle core copper cable for Line 95 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 96 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 97 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 98 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 99 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 100 Indoor End Termination Kit for above XLPEcable : Dry Plug-In type GIS Indoor Termination kitwith all its accessories complete. This includes cable connecting contact plates and cable terminal box at GIS termination of type-A, Fig -3 as per IEC 60859 with support structure and insulator as per approved drawing, technical specification /requirement as per the following cables. For 33 : Dry Heat Shrink type as per approved drawing, technical specification /requirement as per the following cables. 101 For 220KV 630 Sq.mmsingle core copper cable for Line 102 For 220KV 630 Sq.mmsingle core copper cable forTransformer 103 For 220KV 400 Sq.mmsingle core copper cable for Line 104 132 KV 630 Sq.mm single Core Copper Cable for LV side of 160 MVA Transformer (single phase connection with doublerun cable for each phase ) 105 132 KV 400 Sq.mm single Core Copper Cable forHV side of 50 MVA Transformer & Line feeder(single phase connection with single run cable for each phase ) 106 33 KV 630 Sq.mmSingle Corecopper cable for LV side of 50MVA Transformer (single phase connection with two run cable for each phase) 107 33 KV 240 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer, two 315 KVA Auxiliary Transformer,( Three phase connection with single run cable ) 108 11 KV 400 Sq.mm size Three Core for three 6.3MVA 33/11KV Transformer(Three Phase Connection Single run cable) 109 Generator 110 DG set 100KVA with all accessoriesas per Technical specification 111 Communication Equipment (As per technical specification, BOQ and mentioned Annexure) 112 Fibre Optic Terminal equipment ( with minimum five redundantdirections with MSP protection)/Optical Line Terminal Equipment (SDH-STM 4) for the Sub Station Reduntant Power Supply card and Control card etc. complete to meet Tech. Spec. Requirement in all respect ( should be compatible with FO equipment at BAPL,SLDC & Backup SLDC for data and voice communication and carrier aided protection). 113 E1 Interface cards( Minimum 16 interfaces/card) 114 Ethernet Interfaces10/100 Mbps with Layer-2 switching ( Minimum 8 interfaces/card) 115 Equipment Cabinets 116 Main Distribution Frame (100 pairs) 117 Pre-connectorised optical fibre patch cords as per requirement 118 E-1 Port Interfacing Cable 119 EPAX (with cabinet)To be suitable both for FO Equipment and PLCC equipment with 2 digit, 3 digit & 4 digit Station numbering facility and programmable features such as using analog telephone & Laptop with (4 x 8 nos.) Local Subscribers 120 Digital Teleprotection Coupler suitable for integration with SDH terminal equipment to communicate on G 703 (E1, 2 Mbps) with minimum eight commands as per Technical Specification requirement. 121 Telephone Receiver (2-wire) for connection with EPAX,to be installed at different rooms of GIS cum Control& office building, C-type quarter, Colony buildings, Security room at main gate and other areas as per direction of Site-In-Charge. 122 Telephone cable (armoured) for all2-wire telephones & other requirements as per specification and as per requirement 123 STP Data Cable(CAT 6) with flexible GI conduit pipe for data transfer and for connecting IP phones (placed at Control room, communication room, Sub-Station In-charges room etc.) with FO Panel 124 Two no. licensed software for configuration of SDH and DPC to be handed over in two pendrive to Communication wing 125 48V, 300AH VRLA type Battery 126 48V, 60A Battery Charger 127 48V DCDB as per technical specification 128 Integration withexisting Fiber Optic System at connecting Sub-Stationon optical channel (STM-4), in consultation with the OEM, whose equipment is installed at other end. i) for voice & data communication ii)for carrier aided protection purpose -with supply of equipment and material(SFP,Patchcord, etc) as required. Intigration of new SDH, with existing SDH at connecting substation must not affect repoting of existing SDH at NMS, for which necessay action needs to be taken. 129 SAS system (as perindicative Scheme diagram, Technical Specification and requirement) -Monitoring & Control of the Sub Station from a far end Operting Station in addition to local unit 130 Rack mounted Main Server (Intel XeonSilver 4215processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-1, for connection FO port to be considered). 131 Rack mountedStandbyServer (Intel Xeon Silver 4215 processor or higher) with KVM console with display & all accessories ( server is to be mounted at SERVER PANEL-2, for connection FO port to be considered). 132 Local HMI (client Terminal) with 32 Monitor (LED) 133 Remote HMI PC with monitor (32LED) and necessary software for remote control and monitoring via local substation Gateway ,shall support IEC60870-5-104and IEC 61850 protocol. Remote HMI shall 100% replication of local substation HMI in all respect . 134 MainGateway (Intel Xeon Silver 4215 processor or higher)-Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol. 135 Standby Gateway (Intel Xeon Silver 4215 processor or higher)- Bay level data shall report to GATEWAY & SERVER independently. support simultaneous communication with 4 independent Master stations over IEC 104 protocol 136 Disturbance Recorder Cum Engineering Workstation PC (Industrial Grade) withMonitors (24 size- LED) 137 1 no PC with monitor (24 size LED) and necessary software for remote end to fetch DR data from relays and to configure all relays . 138 Rack mounted complete GPS unit, to be mounted in server panels . 139 Laser Colour Printer (suitable for at least A3 size) 140 Dot Matrix Printer 141 PRP Compliant, managed 20 FO port Ethernet Switch, industrial grade. 142 SAS application software with required license (suitable for 8000 signals, with life time validity) and other relevant operating & system software for running the scheme successfully. 143 Redundant Inverter of 5KVA or higher capacity in HOT-STANDBY Mode, on220V station battery , to feed SERVER, GATEWAY, HMI, Engineers WorkStation,Monitors, Ethernet Switches, KVM Switches,Printers, MODEM/ROUTER, etc. 144 Cabling System -Multimode / Single Mode Dual Window armoured fibre optic approach cable as required with HDPE duct, Flexible GI Conduit, all other power & control cables, Jacks, connectors and any other hardware to meet functional / performance requirement. 145 LIU having minimum 12 ports. 146 Red Box having minimum 4 RJ45 & 2 FO ports. 147 Remote Monitoring & control (wherever required) of Station Auxilliary System like Fire Fighting System, Air Conditioning System, Battery System, Lighting System, ACDB, 220V & 48V DCDB,replica of annunciator with buzzer & reset arrangement,& fire fighting annunciatoretc. complete as per technical specification requirement. For auxilliary system, AUX BCU to be mounted in separate panel. 148 Premium quality Integrated Control console deskwith chairs and other furnituresfor HMI Workstations, DR PC, telephones, storing of log sheets & manuals etc. suitable for three operators 149 Data Integration with SLDC and Back up SLDC End Including programme as per technical specification and also as per site requirement by directly communication with agency engaged for AMC of SCADA at SLDC and Back up SLDC End. 150 Router cum firewall shall be provided at local end for remote data transmission . 151 Network panel and other material / equipment / accessories required for successful completion ofthe job . 152 Automated notification in the form of SMS - i) SMS is required to be sent to 5 (five) mobile numbers at a time. ii) When required, any number can be deleted or altered. For that easy interface is to be provided. A log (with user-id and time) for the same is also required to be maintained. iii) The type of disturbaces or trippings for which SMS to be sent must be cofigurable. iv) All required hardwares and softwares to establish the system is under scope of the bidder. v) ISP connection in the name of WBSETCL and any formalities (if required) is to be done by the Bidder.SIM will be provided by WBSETCL. vi) After handing over the system, any recurring charges for SIM will be borne by WBSETCL. 153 Vendor Assessed Quantities: 154 ACDISTRIBUTION BOARD(comprising of Main ACDB, Sub-ACDBMLDB,DB) complete as per technical specificationand as per requirement. In addition to incomers from 2 nosStation Transformer, and Diesel Generator, suitable incomer for Solar Roof Top plant (40 kWp capacity) is to be considered as per requirement for GIS building and 11 KV room . 155 DCDISTRIBUTION BOARD (220 V DC)complete as per technical specificationand as per requirement 156 30V DCDB (with single source) for 11 KV System as per uploaded Tech spec 157 Control cable 1.1KV grade( Cupper ) as per TECH Spec and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing . Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 158 19 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 159 16 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 160 12 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 161 8 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 162 4 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 163 5 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification.(For all CT, PT & CVT connection. For CT individual colour coded cables are to be used for individual core). 164 4 core, PVC, Armoured4 Sq. mm Copper as per Technical Specification. 165 5 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 166 3 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 167 2 core, PVC, Armoured2.5 Sq. mm Copper as per Technical Specification. 168 POWERCABLE-Multi Core, PVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification and as per requirement as per approved drawing and cable schedulefor entire work including cable laying fromACDB & DCDB ,paneland any other equipment and also any equipments supplied by WBSETCL including Supply and installation of all required cables as per transformer & RTCC scheme drawing (Allcablesshall be of Copper only.)Actual quantity will be finalised as per approved drawing and cable schedule and as per requirement 169 1C X 500 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 170 3.5C X 185 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 171 4C X 16 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 172 4C X 25 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 173 4C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 174 4C X 35 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 175 2C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 176 1C X 50 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 177 2C X 4 sq. mmPVC, Armoured, 1.1 KV POWERCABLE (Copper) as per Technical Specification 178 ACSR CONDUCTORwith accessoriesas per Technical Specification and as per requirement 179 ACSR Moose 180 ACSR Panther 181 Earth /Shield wirefor LM down comer 182 ALUMINIUM TUBULAR PIPE (Schedule 80) as per Technical Specification and as per requirement 183 3 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 184 2.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 185 1.5 IPS ALUMINIUM TUBULAR PIPE as per Technical Specification and as per requirement 186 CLAMPS,CONNECTORS,BUNDLE SPACER, Hardware fittings & accessoriesincluding equipment connectors(SUITABLE FOR SCH. 80) and as per approved ACSR conductor as per Technical Specification and as per requirement 187 220KV System 188 132KV System 189 33 KV System 190 11KV System 191 0.4KV System 192 Solid Core POSTINSULATOR& Anti fog type Disc insulatorwithhardware fittings and accessories as per Technical Specification andrequirement 193 220KV System 194 132KV System 195 33 KV System 196 11KV System 197 ILLUMINATION SYSTEM 198 ILLUMINATION SYSTEM COMPLETE (Both Indoor & outdoor)GIS building control building switchyard periphery C type building B type buildingPump House, Security Goomty / Barrack, DG Room,other area installation including light pole with foundation worketc as per technical specificationandrequirement. Allluminaire used shall be of LED type (irrespective of the type mention in specification) and all fans shall be of energy efficient BLDC type. 199 Dehumidifier as per specification 200 Dehumidifier with suitable capacity & size for 33 KV Switchgear Roomas per approved drawing 201 Direct Stroke Lightning Protection for GIS building(considering Roof Top Solar Plant), Control builting, FFPH, as per relevant IEC. 202 Furnitures and Gadgets for Conference Room - Premium quality furnitures of reputed brand like Godrej or equivalent are to be considered. However, before procurment of furnitures and gadgets, written approval from WBSETCL site-in-charge is to be taken. 203 Conference table suitable for 30 person 204 Executive High Back chairs 205 Digital Audio / visual projector - 4K resolution, 2 nos USB 2.0 and 2 nos HDMI 2.0 ports (Preferred make - Sony, Epson, JVC, Panasonic) 206 64 or higher Interactive smart whiteboard of reknowned make 207 Meeting room Audio system (microphones - 30 nos., wall mounted speakers, amplifiers, other required hardwares & softwares) - (Make Harman, Sennheiser or equivalent) 208 Decorative dimmable LED lights (average 500 lux level) 209 High quality window blinds matching with room interior 210 AIR CONDITIONING SYSTEM COMPLETE as per Technical Specification and as per requirement (All machines must be of same make.) 211 RelayRoom and SAS Room & communication Room- Ductable Air Conditioning System is to be considered. -All machines must be ofsame make . Considering continuous operation ,machines must be of Industrial gradeand refrigerent must be of R32 or better environmental standards .as per spec 212 5star rated Split type Non-Ductable AC for Battery & Chargerroom, In-Charge Room, Conference room DB Room etcAll machines must be ofsame make . Considering continuous operation, machines must be of Industrial grade / 5 star rated split and refrigerent must be of R32 or better environmental standards as per spec 213 FIRE FIGHTING & FIRE PROTECTION SYSTEM - As per Tech spec 214 Fire hydrant system in ring formation along the periphery of switchyard covering entire portion (Entire 132 KV Switchyard &220 KV switchyard), GIS building, Control Building etc as required. 215 Portable fire extinguisher & bucket at key locations of switchyard ,control room, GIS building, office area ,residential and other building and near each Power Transformer as per Technical spec . and as per requirement. 216 Fire Alarm System (Concealed cabling is preferred ) - i) Smoke & heat detection system covering all the rooms of GIS cum Control room building ii) adequatebeam detector with redundancyfor GIS room - as per technical specification & requirement 217 CCTV Survelliance system (as perTech specification ) - The system shall be capable to integrate with central control centre. The actual quantity shall be finalised depending on the approved design . 218 Fixed Bullet camera (short range) with all accessories -as per technical specification. 219 Fixed Bullet camera (long range) with all accessories -as per technical specification. 220 Fixed Dome camera with all accessories-as per technical specification. 221 PTZ camera with all accessories-as per technical specification. 222 IP Based Outdoor Thermal Camera with all accessories as per technical specification 223 VMS management server with 30 days recording facility for minimum 40 cameras (with MS Windows professional operating system) -as per technical specification. 224 Video surveillance software and license for 40 cameras or more (which shall be valid for lifetime) -as per technical specification. 225 40 4K Display, 24 x 7 operation; as per technical specifications 226 2 KVA online UPS with 30 minute backup-as per technical specification. 227 24 Port PoE 1G Network Switch with 4 nos SFP Ports along with 1G SM SFP Modules; as per technical specifications 228 Required number of Industrial Grade 4 Port 1G Network Switch with 2 Nos. SFP Ports along with 1G SM SFP Modules; as per technical specifications 229 Media Converter, PTZ keyboard with joystick, cabinet, junction box, POE injector, LIU, power supply, Indoor floor mount rack, outdoor rack, clamp, connector and hardware for camera fixing etc. -as per technical specification. 230 All types of armoured fibre optic cables, CAT 6 cables, armoured copper cables, HDMI cable, HDPE conduits, PVC straight pipe and accessories etc. required to complete the system-as per technical specification. 231 Computer Table, rolling Chair, additional mounting pole and Other tit-bit materials not specified above but required for successful completion of CCTV surveillance systemas per site requirement. 232 NEXT GENERATION FIREWALL/ CYBERSECURITY GATEWAY and all required hardwares & software for integration with remote Control Command & Centre AS PER TECHNICAL SPECIFICATIONS. 233 One additional viewing unitsat In-Charge Room with all required hardware and software 234 SUBSTATION EARTHING SYSTEM : As per Technical specification 235 32mm dia or higherMS rod for main earthmat grid,corner mesh and periphry for outdoor switchyard . The actual quantity shall be finalised depending on the approved design (Only design quantity with lap length without any wastage for main mat, periphry& corner mesh will be considered for payment.) The Earthmat design is to be done considering earth resistivity of 30 Ohm-m oractual measured value whichever is higher. 236 32mm dia or higherMS rod for riser below and aboveground auxiliary Mat fencing and gate earthing bending length and overlapping length as per requirement & as per approved drawing 237 GS flat for riser above ground / cable trench & other areas.Rod/pipe electrode , test link and other materials etc. - as per requirement, technical specificationand approved design/layout including earthpit. 238 Earthing for GIS enclosure and GIS building as per manufacturers recommendation including civil work. 239 Earth Link Box, SVL, Earth Strip, earth continuity cable for single bondwherever required for Earthing of allXLPE Cablecomplete at cable conductor junction point etc as per technical requirement / as per approved drawings. 240 Earth Strip and other accessories including lugs for link box etc wherever required for Earthing of allXLPE Cablecompletei as per technical requirement / as per approved drawings. 241 3 ph Earth Link Box with SVLas per technical requirement / as per approved drawings. 242 3 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 243 1 ph Earth Link Box with SVL as per technical requirement / as per approved drawings. 244 1 ph Earth Link Box with outSVL as per technical requirement / as per approved drawings. 245 6.6 KV/3.8 KV Copper Bonding Cableas per technical requirement / as per approved drawings. 246 1.1KV Grade 240 sqmm CopperEarth continuity Cableas per technical requirement / as per approved drawings. 247 GRID CONNECTED ROOF TOP SOLAR POWER SYSTEM (As per Technical Specification) 248 5kWpSolar Roof Top plant (at the roof of GIS & Control building) having high quality mono. crystalline type solar PV module from reputed brand (as mentioned under WBSETCL Makers list), Mounting structures (Fixed Type) with Civil pedestals including civil work as per requirement. 249 i) High quality inverter from reputed brand as mentioned under WBSETCL Makers list) suitable for 40kWp solar roof top plant. ii ) All other required accessories- Data logger with CPU, LCD monitor, UPS,Metering,Junction box & distribution boxes, Type-II Surge protective device, string monitoring uints, pyrano.meter with sensors, all Cables, hardware, earthing & lightning protection materials, required furnitures & cabinets, conduits etc. to complete the system of 40kWp grid connected plant 250 Essential spares necessary for operation, routine maintenance and testing of equipment supplied for 3 years to be covered under Annual Maintenance Contract. 251 MISCELLANEOUS ITEMS -As per Technical specification 252 i) Glow signboard for name of the substation- minimum size 50 sq ft, ii) schematic SLD on glow signboard iii) Danger plate, phase plate, bay nameplate etc iv) Statutory caution boards made of mild steel of 250 mm x 200 mm and at least 2 mm thick and vitreous enamelled, white on both sides and with inscription in signal red colour on front side as required. v) Shock treatment chart in local and English language duly mounted on wooden frame with glass as required vi) Safety Slogans - to be put up in Offices and Sub-station premises (Site-in-charge may select the slogans from WBSETCL Safety Manual, Version 2.0, Page 18)vii) WBSETCLLOGO & Sub-Station Nameat main gate of Sub-Station entry with good quality durable materials 253 Ferrules & lugs, GI conduit, Cu flexible wires for panel earthing etc. 254 .Angle, Channel and other hardwares for installation of panels, DBs etc. 255 Supply of itemsfabrication marker, tags,Protection cover tiles, PVC warning tape, route marker, jointing marker, clamps connector etc as per specification & approved drawing 256 Trefoil clamp suitable for approved XLPE cable 257 Bay marshalling kiosk, dummypanel, junction box, , Lighting & other Distribution Boards etc. As per requirement& as per Technical specification 258 Bay marshalling kiosk, 259 Dummypanel, 260 Junction box, (CT,PT,CVT as per requirement 261 Distribution Boards as per requirement 262 Cable Tray (Ladder type & perforated type etc ) as per requirement for indoor cable trench and and as per requirement within GIS building 263 Industrial type Exhaust Fans and mechanised louvers of required quantity for 220KV & 132KV GIS Hall, 33 KV indoor switchgear& 11 KV Switchgear Room as per requirement & as per Tech Spec 264 HDPE Pipes 265 200 mm Dia 266 150 mm Dia 267 One storage type RO + UV + UF water purifier for office building 268 Spares:- Spare relays including test jack are to be delivered after duly tested at CTD WBSETCL on chargeble basis. All materias will be as per scheme of this project ) 269 Distance Protection relay (as approved at 220 KV Line bay for Main-1 potection) 270 Distance Protection relay (as approved at 220 KV Line bay for Main-2 potection) 271 Distance Protection relay (as approved at 132 KV Line bay for Main-1 potection) 272 Distance Protection relay (as approved at 132 KV Line bay for Main-2 potection) 273 Transformer differential Relay(same as approved for 220 KV Transformer bay) 274 Transformer differential Relay(same as approved for 132 KV Transformer bay) 275 BCU (same as approved for 220KV bays ) 276 BCU (same as approved for 132KV bays ) 277 BCU (same as approved for 33KV bays ) 278 BCU (same as approved for auxilliary system) 279 PRP Compliant, managed Ethernet Switch, industrial grade. (same as approved for SCADA Systeml) 280 Over Current& Earth fault Relay 281 Bus Bar Differential Relay (One Central Unit and one Peripheral Unit) 282 Trip Relay 283 VT selection Relay 284 Spares: Spare are to be delivered at nearest store in consultation with in charge All materias will be as per scheme of this project. 285 220KV GIS Circuit Breaker complete mechanism 286 220KV GIS Disconnector complete mechanism 287 220KV GIS High speed earth switch complete mechanism 288 132KV GIS Circuit Breaker complete mechanism 289 132KV GIS Disconnector complete mechanism 290 132KV GIS High speed earth switch complete mechanism 291 33KV CT - same as supplied for Line bay 292 33KV CT - same as supplied for 50 MVA Transformer bay 293 Safety Equipment 294 Full Body Safety Harness with Twin rope lanyard, length < 3 meter with waist belt and accessories as per IS - 3521 295 First aid box complete with all items (as perAnnexure in line with WBSETCL Safety Manual, Version 2.0) - to be placed at Control Room & Maintenance Room 296 Discharge cum earthing rod - Highly insulated FRP telescopic type with all accessories suitable for 245 KV system or higher,CPRI type tested as per IEC - 1230:1993 & IEC - 1235 with tested epoxy earthing rod for 10 KV /ft for 1 min as per IEC- 855 297 Safety Helmet - Made of Polyethylene/ glass fibre reinforced with head band, cradle, strap fittings with withstanding temp of 50oC as per IS – 2925 (Suitable stand / Racks are to be provided to store the helmets. Helmets are to be colour coded for visitors, technical staff and others) 298 Gum Boot made of Rubber (Suitable stand / Racks are to be provided for storage.) 299 Renowned make High Voltage Detector - Suitable for 11 KV to 245 KV , 50 HZ system with sensing level 1 mtr. for 132/220/ 400 KV system complete with HV probe, 5.0 mtr telescopic insulation stick with visual LED and Buzzer indication as per IS - 13771/ IS - 2071 300 Safety shoes - Double density PU sole, leather with hard Toe cap, Non-woven Eva lining, anti static /electric shock proof Insole (with minimum electrical resistance and high voltage of 18 KV), conforming to IS – 15298 301 Hand Gloves - Made of soft quality rubber, seamless latex, shock proof, for electrical purpose suitable upto33 KV -system as per IS - 4770 302 Electric Arc Protection Suit - FR suit compatible to wearwith hood, jacket, face shield, trouser etc complaint with NEFA- 70 E standard as per IEC - 61482-1-1-2007/9 303 Insulating mat - High density insulating matsasper IS - 15652 with ac(rms) kv 3.3, sizes of rolls 5000 mm X 1000 mm (to cover entire operating length of 33KV switchgear, DB room & Panel room) 304 Safety Ladder - Single step self supporting type with complete Fiber glass, 3 inch wide, antiskid fibre steps, non - slip fibre glass shoes with thick rubber pad, Height 8 ft 305 Safety Torch / Search Light - Body:- Fibre glass, PCB - glass epoxy to meet all weather condition, Circuitry - IC Control, Charge -220 Volt AC, Light Source - 12 V Halogen Bulb, 55 watt, Power source - 12 volt, 7 AH sealed battery, Extra jack tobe provided for direct lightning by 12 volt DC, Continuous run - 2 hr High beam Rechargeable Hand Held Search light 306 Lifting Rope - Hemp Rope / Sisal Rope / Manila Rope - One inch dia., 30mtr long 307 Passenger Elevator (6 person capacity, ) - For GIS & Control buildingcomplete in all respect as per technical specification and as per requirement. 308 Industrial grade Vacuum Cleaner of reputed make 309 Civil Part: 310 Supply, fabrication, galvanisaton of variousswitchyard & equipment structures,LM-Lattice type ( 35Mtr or 50 Mtr-based on DSLP Calculation), XLPE cable supporting structure completeas per approved electrical layoutdrawings and technical specification (Electrical & civil) and as per requirement complete. (including Nuts & Bolts and foundation bolts) 311 Switchyard Structures including Nuts & Bolts 312 Foundation Bolts for switchyard structures including nuts, washers and anchor plates (Foundation Bolts shall be galvanisedupto threaded length from top) 313 Supply, fabrication of various structures (MS FLAT, MS Plate, Insert plate, Angles, Transformer Rail, Channels, ISMB, Chequred plate, MS grating for GIS Building, Transformer, Cable trench , drain etc. as per approved drawings, technical specification (Electrical & civil) andrequirement complete.
Contract Date: May 11, 2026 Contract Value : 242.30 Crore
Government Departments No of Bidders 3
West Bengal View Result →
3.
Housing Urban and Rular Development #10825582 Price Bid
repair maintenance of Electrical And Mechanical Services Of Various Office Building At Probin Road , Lucknow Road , Delhi . ( Sh- Servicing , Overhauling And Amc Of Split-Windows Air Conditioners And Water Cooler ) , comprehensive running maintenance of window type a . c unit / split type a . c unit / cassettes type a . c units of 1 . 5 t . r / 2 . 0 t . r capacity . water cooler/ ductable ac coloum etc . for twelve months ( 8 months summer+ 4 months winter ) after completion of servicing overhauling repairing etc bimonthly as required at site i/c servicing of wtac /stac/cassette type a . c units including cleaning , washing with high pressure water spray electric machine , coil cleaning with chemical , blower oiling , greasing including replacement of blower , motor , compressor , pcb , plug top , 3 core copper conductor cable , starting/running capacitor of suitable size , relay suitable for 1 . 5 , 2 tr unit , condensor fan , filter pvc , fan blades , thermostat , remote and all types of defective parts for proper functioning of equipments , condenser coil , cooling coil , charging of refrigerant gas to make the already installed w . t . /split/cassette type a . c units fully functional with genuine spares and reinstallation of the same etc . complete as required . the ac units/water cooler will be handed over to the agency on as it is where it is bases for servicing and comprehensive maintenance . the firm is advised to visit the site , before quoting the rates . all the above units were functional last year , nothing extra shall be paid for above items for making the units fully functional , testing and commissioning complete as reqd . ( note:- the contractor is required to complete the servicing & repairing of all air conditioning equipments/water coolers within a period of one month and submit the record to the department . the comprehensive maintenance shall be treated as started only after acceptance by the department that all equipment have been serviced by contractor . ) the contractor will handover all the unit in fully functinal condition on completion of the work . dismentaled material will be taken back by the contractor for which necessary rebate shall be considence while quoting the rates . ( total nos= 131 , inventory attached ) a ) summer ( 8 months ) , b ) winter ( 4 months )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 7
4.
Housing Urban and Rular Development #10612230 Price Bid
1 ) repair maintenance of electrical and mechanical services of vrs social welfare bldg . at sewa kutir , kingsway camp 2 )repair maintenance of electrical and mechanical services at juvenile jail , majnu ka tilla 3 ) rmo e and m services at da flats , timarpur , delhi . ( sh - servicing , overhauling and amc of split / window acs and water cooler ) , ( part-a ) comprehensive running maintenance of window type a . c unit / split type a . c unit / cassettes type a . c units of 1 . 5 t . r / 2 . 0 t . r capacity water cooler / ductable ac coloum etc . for twelve months ( 8 months summer+ 4 months winter ) after completion of servicing overhauling repairing etc as required at site i / c servicing of wtac / stac / cassette type a . c units including cleaning , washing with high pressure water spray electric machine , coil cleaning with chemical , blower oiling , greasing including replacement of blower , motor , compressor , pcb , plug top , 3 core copper conductor cable , starting / running capacitor of suitable size , relay suitable for 1 . 5 , 2 tr unit , condenser fan , filter pvc , fan blades , thermostat , remote and all types of defective parts for proper functioning of equipments , condenser coil , cooling coil , charging of refrigerant gas to make the already installed w . t . / split / cassette type a . c units fully functional with genuine spares and reinstallation of the same etc . complete as required . the ac units / water cooler will be handed over to the agency on as it is where it is bases for servicing and comprehensive maintenance . the firm is advised to visit the site , before quoting the rates . all the above units were functional last year , nothing extra shall be paid for above items for making the units fully functional , testing and commissioning complete as reqd . ( note:- the contractor is required to complete the servicing & repairing of all air conitioning equipments / water coolers within a period of one month and submitt the record to the department . the comprehensive maintenance shall be treated as started only after acceptance by the department that all equipment have been serviced by contractor . ) the contractor will handover all the unit in fully functional condition on completion of the work . dismentaled material will be taken back by the contractor for which necessary rebate shall be confidence while quoting the rates . a ) summer ( 8 months ) for 208 unit , b ) winter ( 4 months ) for 60 unit , comprehensive running maintenance of window type a . c unit / split type a . c unit / cassettes type a . c units of 1 . 5 t . r / 2 . 0 t . r capacity water cooler / ductable ac coloum etc . for twelve months ( 8 months summer+ 4 months winter ) after completion of servicing overhauling repairing etc as required at site i / c servicing of wtac / stac / cassette type a . c units including cleaning , washing with high pressure water spray electric machine , coil cleaning with chemical , blower oiling , greasing including replacement of blower , motor , compressor , pcb , plug top , 3 core copper conductor cable , starting / running capacitor of suitable size , relay suitable for 1 . 5 , 2 tr unit , condenser fan , filter pvc , fan blades , thermostat , remote and all types of defective parts for proper functioning of equipments , condenser coil , cooling coil , charging of refrigerant gas to make the already installed w . t . / split / cassette type a . c units fully functional with genuine spares and reinstallation of the same etc . complete as required . the ac units / water cooler will be handed over to the agency on as it is where it is bases for servicing and comprehensive maintenance . the firm is advised to visit the site , before quoting the rates . all the above units were functional last year , nothing extra shall be paid for above items for making the units fully functional , testing and commissioning complete as reqd . ( note:- the contractor is required to complete the servicing & repairing of all air conitioning equipments / water coolers within a period of one month and submitt the record to the department . the comprehensive maintenance shall be treated as started only after acceptance by the department that all equipment has been serviced by contractor . ) the contractor will handover all the unit in fully functinal condition on completion of the work . dismentaled material will be taken back by the contractor for which necessary rebate shall be confidence while quoting the rates . a ) summer ( 8 months ) for 131 unit , b ) winter ( 4 months ) for 33 unit
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
5.
Housing Urban and Rular Development #10542166 Price Bid
1 ) Rmo E And M Services Of Vrs Social Welfare Bldg At Sewa Kutir , Kingsway Camp . 2 ) Rmo E And M Services At Juvenile Jail , Majnu Ka Till , Delhi 3 ) Rmo E And M Services At Da Flats , Timarpur , Delhi . ( Sh- Servicing , Overhauling And Amc Of Split-Windows Acs And Water Cooler ) , Comprehensive Running Maintenance Of Window Type A . C Unit / Split Type A . C Unit / Cassettes Type A . C Units Of 1 . 5 T . R / 2 . 0 T . R Capacity . Water Cooler/ Ductable Ac Coloum Etc . For Twelve Months ( 8 Months Summer+ 4 Months Winter ) After Completion Of Servicing Overhauling Repairing Etc Bimonthly As Required At Site I/C Servicing Of Wtac /Stac/Cassette Type A . C Units Including Cleaning , Washing With High Pressure Water Spray Electric Machine , Coil Cleaning With Chemical , Blower Oiling , Greasing Including Replacement Of Blower , Motor , Compressor , Pcb , Plug Top , 3 Core Copper Conductor Cable , Starting/Running Capacitor Of Suitable Size , Relay Suitable For 1 . 5 , 2 Tr Unit , Condensor Fan , Filter Pvc , Fan Blades , Thermostat , Remote And All Types Of Defective Parts For Proper Functioning Of Equipments , Condenser Coil , Cooling Coil , Charging Of Refrigerant Gas To Make The Already Installed W . T . /Split/Cassette Type A . C Units Fully Functional With Genuine Spares And Reinstallation Of The Same Etc . Complete As Required . The Ac Units/Water Cooler Will Be Handed Over To The Agency On As It Is Where It Is Bases For Servicing And Comprehensive Maintenance . The Firm Is Advised To Visit The Site , Before Quoting The Rates . All The Above Units Were Functional Last Year , Nothing Extra Shall Be Paid For Above Items For Making The Units Fully Functional , Testing And Commissioning Complete As Reqd . ( Note:- The Contractor Is Required To Complete The Servicing & Repairing Of All Air Conditioning Equipments/Water Coolers Within A Period Of One Month And Submitt The Record To The Department . The Comprehensive Maintenance Shall Be Treated As Started Only After Acceptance By The Department That All Equipment Have Been Serviced By Contractor . ) The Contractor Will Handover All The Unit In Fully Functinal Condition On Completion Of The Work . Dismentaled Material Will Be Taken Back By The Contractor For Which Necessary Rebate Shall Be Confidence While Quoting The Rates . ( Total Nos= 208 , Inventory Attached ) A ) Summer ( 8 Months ) , B ) Winter ( 4 Months )
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 8
6.
Housing Urban and Rular Development #10392168 Price Bid
Amc Of Ei At Nigs, Medinipur Sadar- Day To Day Annual Maintenance Of Electrical Installations Including S And D Of Maintenance Materials - Day to day Annual maintenance of Electrical installations of NIGS, Medinipur Sadar, Paschim Medinipur.Charges for providing 1 No Electrician, 1 No Helperfor 1(One)shift as per Scope of work, terms & condition given below. every Day(incl. holy day) including emergency break down etc. of beyond maintenance hour if required] 2 S & D of 18W PC body LED Tube light.(Make - Crompton, Cat No.- LTT8-20 or equivalent of Wipro/Phillips) 3 S & D 9W 900 lumen LED bulb B22. (Make- Philips/Crompton/Wipro) 4 S & D of Push Holder For Tube light.(Make- Philips/Crompton/Wipro) 5 S&D of Angular batten Holder (Anchor) 6 S & D 2.5 mF capacitor metal body for ceiling fan.(Make:Tibcon) 7 S & D Fan Bearing 6201(Make -SKF/Tata) 8 S & D Fan Bearing 6202(Make -SKF/Tata) 9 S & D 415 V 63A TP MCB of Breaking capacity 10kA & C characteristics(Make: L&T/Havells/Legrand) 10 S & D 240 V 6-32A SP MCB of Breaking capacity 10kA & C characteristics(Make: L&T/Havells/Legrand) 11 S&D 240V 40A DP MCB Isolator (Make: L&T/Havells/Legrand) 12 S&D 125A HRC HN type fuse(L&T/ Siemance/Havells) 13 S&D 63A HRC fuse HF type fuse(L&T/Siemance/Havells) 14 S & D of 240 V 6 A Piano key type switch(Make - Anchor) 15 S & D of 240 V 16/20 A Piano key type switch(Make - Anchor) 16 S & D of 240 V, 6A plug socket(Make - Anchor) 17 S & D of 20 A plug socket(Make - Anchor) 18 S & D of Socket type fan regulator (Step type)(Make - Anchor) 19 S & D of 1100V grade FR PVC insulated 1.5sqmm(22/0.3) stranded copper wire(Make - Finolex/RR/Havells/KEI/Plycab) 20 Supply of 240V AC 1200mm Sweep ceiling fanscomplete with all accessories having the following specification. (Make-Usha triker plus /Orient Summer cool or equivalent of Crompton High Speed) 21 S & D of industrial LED batten for fixing 1200mm retrofit 18/20W tube light(Make - philips/ Crompton/Wipro) 22 Single Industrial Batten 23 Twin Industrial Batten 24 SCOPE OF WORK:- I) FOR EI MAINTENANCE:-a) The primary objectives of preventive and corrective maintenance are to minimize electrical breakdowns and faults, prevent fire hazards arising from electrical short circuits and faults, and reduce downtime. Any fire hazard incidents resulting from short circuits, or the falling of ceiling fans, luminaries, etc., due to inadequate maintenance will be treated with utmost seriousness. The maintenance agency shall be held accountable for such incidents.b) The electrical installation includes entire cabling network and wirings, BDB’s, PDB’s power & distribution cables,Compound lights, fittings & fixture. LT panels,UPS system etc.c) working time: 1 no Electrician, 1 no Helper FOR 1(One) shift every Day including holy day. At the time of emergency breakdown etc. of beyond maintenance hour agency must be provite staff to restore the problem. 25 ADDITIONAL & SPECIAL TERMS & CONDITIONS OF CONTRACT FOR EI MAINTENANCE:- The agency must provide measuring/operating equipment such as digital multimeter, clambmeter, thermal imeger, earth regeistance tester, low voltage insulation mager, hot air blower, air blower, screw driver set, all type of spaner, cable puncher etc. to the employed staff. 26 The agency shall maintain one Call Book which shall record all the calls alongwith remedial action taken, duly verified by the Junior Engineer/Assistant Engineer periodically. 27 Separate Log book is to be maintained for all L.T. installation . The daily record of the Log book is to be signed by the licensed Supervisor of the contractor and verified & signed by concerned Junior Engineer & Assistant Engineer; and the same should be sent to the Executive Engineer through proper channel at the time of submission of bills. 28 Recording of various electrical parameters (with co. own tools/equipments) of different L.T. panel board, BDBs, Main switches etc, are to be made in Log book in regular manner and the necessary working report in this respect to be submitted monthly to the concerned Assistant Engineer & Junior Engineer every day. Thermal imager should be used in measuring/observing temperature rise of electrical equipments like Cable, BDBs, L.T. panel boards, AC, Light fittings, etc. regularly to find out any abnormalities and the measurements are to be recorded in Log book compulsorily in proper manner every day. 29 In case, any abnormal reading is noticed, then the same should be rectified/set right immediately by taking prompt, appropriate & effective measures/actions by proper recording under intimation to the concerned Assistant Engineer & Junior Engineer. 30 The agency will check and clean all the ceiling fans exhaust fans, stand fans etc. to prevent falling down of those as a measure of safety and maintain a register mentioning fan numbers etc. including keeping those light fittings and fans clean as per the direction of Assistant Engineer or respective Junior Engineer. 31 All the ceiling fans of every Buildings are to be inspected, at least once in 3(three) Months, in respect of Split Pin, Jam nut, fan clamp & suspension arrangement etc. to avoid unwanted falling of Ceiling Fans, failing which responsibility will be fixed up upon the agency (in case of falling of ceiling fans). Report regarding physical condition of Split Pin & Jam Nut must be submitted quarterly in the format prescribed by the EIC. 32 All the fittings, fixture, panel board, PBDB, SPNDB Main-switches & other Electrical Installation inside all the block/floor/buildings as well as for compound lighting installationmust be kept in a tip top condition by cleaning of all the said electrical equipments, dusting off accumulated dirt, cobweb etc. once in a month, and all the cleaning materials like detergent etc. are to be supplied by the agency free of cost. 33 The agency will have to attend all the break-down/fault of any nature involving electrical installation within the scope of contract and restore the same with its own manpower, tools & tackles keeping entries in Log books mentioning type of faults, nature of work done, fault clearance time etc. 34 All incidents of breakdown shall be immediately reported to the concerned Junior Engineer & Assistant Engineer, or direct to Executive Engineer in exceptional circumstances. 35 All the maintenance staff of the contractor should have proper & constant vigilance and check to ensure that there is no sign of overheating, burning smell, discoloration or sparking/chattering at any of BDBs, panel boards,etc. due to overloading or loose connection/termination. Care should be taken to check any highly unbalanced loading at any point.N.B:Periodical check on daily basis by thermal imager scan is required to be carried out for BDB,PDB,Cables, Panels, , Main switches etcand kepping the record and should be reported to the concerned JE on regular basis. 36 The weekly duty roster of the deputed staff should be submitted in advance. 37 The contractor shall issue identity cards to every member of his staff, regular or substitute. No staff will be allowed to perform duty without proper identity card and the agency shall have to assume responsibility for any untoward incident/situation. 38 The authorized licensed supervisor should attend the site regularly and in case of emergency he should attend without any delay and report the incident to the Engineer in Charge. 39 Frequent change of staff is not allowed. Substitute staff list shall have to be submitted at least one week in advance to the Junior/Assistant Engineer. 40 Recording of attendance should in the in the attendance register as per the direction of the EIC and shall be regularly checked and verified by the concerned Junior Engineer/Assistant Engineer. Monthly attendance report should be submitted along with the Bill. 41 Proof of verification of attendance of the staff deputed in the night shift (10 pm to 6 am) by the authority is mandatory for billing purpose. 42 The agency must have separate contact numbers preferably mobile phone numbers for his office and the deputed Supervisor (maintenance team) so that the communication can be easily made in case of urgency. 43 The space for sitting accommodation for the staff of the agency inside the compound will be provided by the PWD/user authority. 44 The Engineer-in-Charge reserves the right for re-allocation of duty to any or all member of the staff as per the requirement of the site or elsewhere. 45 Materials required as replacement during maintenance of electrical installations like fuse wires, screws, nuts, bolts, washers, AL/Cu socket (up to 35 sq. mm.) dusters etc will be supplied Agency so far as practicable, through a separate Issue register to be maintained by the agency at site. 46 The replaced / dismantled materials generated for carrying out breakdown or preventive maintenance or due to civil renovation / dismantling work are to be carried out and deposited to the respective Section Office or any other locations within the compound by the agency by its own labour / arrangements / tools and tackles as per the direction of the Assistant Engineer concerned. If required, the agency will have to dismantle existing electrical installations in connection with any civil renovation / dismantling work and deposit the same to convenient locations as per the direction of the Assistant Engineer concerned by its own labour / arrangements / tools and tackles. 47 Any fault of electrical installations , LT cables and all sub- panels, distribution boards, related main switches, isolators, earthing attachments, compound lights etc has to be detected, attended and restored by the agency by its own man power with the help of the materials (cables, main switches, DBs, wires, HRC fuses etc)available from this department or as per the terms & conditions of this contract. 48 a) Routine checking and preventive maintenance of the electrical installation has to be carried out by the agency daily with a view to ensure uninterrupted power supply within compound. Any negligence in the part of the agency in complying with any of the above described terms & conditions causing inconveniences to public service will be viewed otherwise and is subject to unilateral penalty, be it detected on the spot of thereafter (even after payment). 49 b) Routine inspection of the electrical and allied installation shall be carried out by the agency every morning to ensure that all the light/fan socket outlets/ AC/ UPS and other items of work, as may be directed by Junior Engineer/ Assistant Engineer/ Executive Engineer from time to time are in order and action for restoration shall be taken immediately for faulty items. 50 In case of any breakdown caused by cable fault, etc. , the agency will have to restore the power supply either with the materials available with this department or arranging the same temporarily and safely till completion of permanent restoration work as may be directed by the Engineer-in-Charge. 51 Maintenance materials, viz. Incandescent lamps, Main switches, Power DB, SPN BDB, Main & Sub-main cables, fluorescent/LED tubes, Chokes, Ignitors, and Condensers etc. will be supplied by the Department. However auxiliary items like screws, nuts & bolts, washers, fuse wire, insulating tapes etc. will have to be arranged by the agency on its own expense. 52 No materials should be taken out of the maintenance site without the permission and necessary Challan of the site-in-charge. 53 The agency will take care to prepare the requisition of materials required for the maintenance within his jurisdiction well in advance and submit the same to the concerned Junior Engineer so that no delay in maintenance/repair / replacement cause trouble in the system & hampering of the service thereof. 54 The repairing of the different type of light fittings, ceiling fans, exhaust fans etc. have to be done by the agency incl. dismantling and re-fixing the same. (Materials to be supplied by Department). 55 In case of power failure or development of any unfavorable situation, the agency will have to communicate with concerned WBSEDCL authority and extend co-operation to them in restoring of power supply. Meanwhile, the agency will have to operate the switching mechanisms of interconnections among available sources at suitable locations to maintain power supply at important locations by monitoring electrical loads in consultation with concerned Junior Engineer/Assistant Engineer. 56 Any major shut down or fault should be brought to the notice of EIC immediately in writing and over telephone for further course of action. 57 Insulation test with the help of Megger for the entire Electrical Installation as well as earth resistance of the earthing installation for each building and also sub-station are to be carried out in the presence of concerned Assistant Engineer/Junior Engineer once in six months and the result thereof is to be furnished to the Engineer –In-Charge through proper channel alongwith the bill. 58 The agency must have separate offices & separate contact telephone nos. for his site office and main/head/branch office and the same should be intimated to this Department in writing. All telephone calls should be responded without delay. 59 The agency should be responsible for any damage in the installation due to mishandling / mal-operation done by his staff and shall be liable for the compensation for the same which would be recovered from the bill as per direction of E.I.C. and the accused staff should be replaced immediately. 60 If any kind of incapability & negligence are noticed in observing all the above-said terms & conditions, this Department posses the right to deduct the cost from the bills of the contractor on pro-rate basis as determined by the Engineer –In-Charge. In that case, the above-said contract may be terminated without issuing any notice whatsoever and stringent & punitive action may be taken against the contractor as may be decided by the Engineer-in-Charge or higher authority. 61 Valid workman’s permits, electrical licence, Diploma certificate, identity proof etc. are to be furnished for each electrician/workman, helper & Diploma Electrical Engineer/Supervisor engaged by the agency along with the name & contact mobile no. of the persons and all these information with supporting documents are to be submitted in written to the concerned Junior Engineer, Assistant Engineer & Executive Engineer. 62 The contract may be terminated by one month’s notice from either side. 63 Any negligence in the part of the agency in complying with any of the above-mentioned terms and conditions and/or causing inconvenience to public service will be viewed seriously and shall be subject to unilateral penalty, be it detected on the spot or thereafter (even after payment of bills). 64 The agency should have been responsible for any damage in the installation due to mishandling or mal-operation. If so, the cost for rectification or replacement will be recovered from the bill on proportionate and the incident will be counted while issuing the performance report. 65 The agency will have to maintain log books in such a manner so that at least one log book may always be made available at site as and when asked for. 66 Bills should be submitted quarterly or as per direction of EIC, keeping at least one spare log book at site. Payment will be made as per PWD norms against placement of bills supported by log book and duly verified by the Junior Engineer / Assistant Engineer. 67 Labour laws : Before undertaking the work as per order, agency must produce labour license obtained from the Assistant Labour Commissioner/Dy. Labour Commissioner’s office in the Region in compliance with the provisions of Central Labour Regulation & Abolition Act, 1970 and the rules made thereunder. He should comply with all labour laws to protect the labourers engaged by him. The successful bidder after placement of the order shall have to comply with following in order to get payment :a) Heshall have to follow the rules and regulations of the prevailing Acts of Central and State Governments.b) Heshall be responsible for compliance of statutory obligation under the Central Labour (R&A) Act, 1978, Minimum Wages Act, 1948, Payment of Wages Act 1936, Bonus Payment Act, 1956, and also be responsible for payment of contribution (Both employer and employee’s) under Provident Fund Act & Employees’ State Insurance Act,1952 in respect of the employee. c) Heshall be solely responsible for any accident, occurring if any, during the course of the work or any injury to any person and in the event of any such accident/injury he will be held responsible and must pay proper compensation for the same as per Workmen’s Compensation Act, 1923 (when Employee State Insurance Act 1948 is not applicable); d)No labour of minor age should be employed; e) Statutory minimum wages for all categories of labour are to be paid as per notifications issued by the appropriate authority of the Government from time to time: 68 Uniform, safety shoes, helmet, raincoat, umbrella, gumboot, torch/ emergency light, etc. and all types of tools and tackles (Like digital multimeter, tongtester, earth regeistance tester, low voltage insulation mager, hot air blower, air blower, screw driver set, all type of spaner, cable puncher, lader etc) are to be provided by the agency to its staff. 69 All the issues related to the safety of the staff should be taken care by the Agency itself. 70 In case of any mishap or accidental injury to any member of the staff deputed by the agency, the whole responsibility is to be borne by the agency but should be informed to the EIC immediately. 71 Any unethical/unruly attitude/behaviour or activity of the agency or any of his deputed staff should be viewed seriously and legal action would be taken accordingly by this end. 72 The philosophy of “Public Interest” would be the ‘motto’ of this maintenance contract. Any deviation may be viewed otherwise and action taken accordingly. 73 It will be the duty and responsibility of the agency to ensure strict compliance of the provisions of the contract. Should any major or recurring deviation or negligence be observed/detected in execution of the contract by the agency during any scheduled/surprise inspection of the higher authority, penal action will be taken with retrospective effect without any further reference/correspondence, and without any prejudice to the right of the Engineer-in-Charge to terminate the contract by invocation of any of the clauses of the contract. 74 The Executive Engineer/ Assistant Engineer the right to depute any members of the maintenance staff to other site, in exigency of public service, restore normally or assist other team members working there. 75 The Maintenance Personnel, deputed by the agency should be a permanent resident of West Bengal with valid Voter / Aadhar Identity Card and should possess valid Workman Permit/ License, as mentioned below, issued by Directorate of Electricity, Govt. of West Bengal.Sl. No Category of Maintenance Personnel Mandatory Requirement 1. Electrical Supervisor SCC Part No. 1,2,3,4,5, 6A, 6B, 7A,7B, 10,11& 12 or National SCC /Highly skulled issueded by, DOE, WB2. Skilled Electrician ITI/ Equivalent Certificate Holder Electrical/ SCC Part No. 1,2,3,4,6A,6B, 7A,7B,11, 12 issued by Directorate of Electricity, West Bengal 3.Semi-Skilled ElectricianWorkman Permit i(a) and/ or i(b) and (ii) issued by Directorate of Electricity, West Bengal 4. Unskilled Personnel/ HelperBasic knowledge of Electrical works (Experience Certificate fromreputed Electrical firm required)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
West Bengal View Result →
7.
Educational and Research Institute #10365642 Price Bid
Tender For Comprehensive Annual Operation And Maintenance Works & Services At Central University Of Rajasthan.; 1 Comprehensive Annual Operation and Maintenance Works & Services 2 SH-I (a) Deployment of Maintenance Gang for day to day Civil Maintenance work at CURAJ 3 SH-I (b) Operation And Maintenance Of 750 KLD Sewerage Treatment Plant at CURAJ 4 SH-II (a) Electrical & Mechanical Preventive And Day To Day Maintenance Works, Annual Operation, Repair, Maintenance And Periodic Servicing Works Of Pump Houses And Annual Electrical Works At CURAJ 5 Annual preventive and day to day maintenance, to upkeep all the electrical internal & external installations, fittings, fixtures, wiring, Lights, Fans, Geysers etc. functional in the CURAJ campus, for all days in a month, including Sundays and Holidays, including manpower, labour, machinery, general maintenance items, tools & tackles for all deputed staff, safety tools for LT & HT power supply, various type of ladders/tipaya/chopaya etc. as required on site, complete in all respects, as per standard practice. Indicative items are as under: • Wiring/Cabling.• Metal/PVC boxes.• Switches, sockets and accessories of different ratings.• 01phase/03 phase power points & circuits.• 01/03 phase Energy Meters.• Light points/ Fan pts/ Exhaust Fan pts/Call bell pts. etc.• All type of indoor and outdoor lights (conventional/LED/HPSV/MVSV etc.) fittings.• All type of fans (Ceiling/Exhaust/pedestal/wall).• HVLS fans.• Water heaters.• Auditorium stage lights.• Air curtains and electric fly catchers.• Rising mains bus trunking and overhead bus bar of different ratings.• Sandwich rising mains with aluminium bus bar of different ratings.• Switch, disconnector, SFU and MCCB of different ratings.• MCBs, Isolators, RCCBs and MCB DBs of different ratings.• Cable and Boxes of different sizes.• Brass compression glands of different sizes.• Aluminium lugs of different sizes.• HT/LT Cable fault detections and jointing kits.• Overhead electric line.• Road lights.• Lightning arrester and earthing system.• All Electrical indoor and outdoor panels and panel rooms of all buildings.• Maintenance of records etc. and as per tender document. 6 Comprehensive Annual Electrical Operation, Repair, Maintenance and Periodic Servicing Works of pump houses and other water & booster pumps/motors/starters along with associated panels and accessories for all days in a month including Sundays and Holidays, including manpower, machinery, spare parts, consumables, tools & tackles for all deputed staff, safety tools for LT power supply, ladders, ropes etc. as required on site, complete in all respects.Note: Tentative quantity of motors & pumps of different ratings is 30. 7 Providing of uniform to all the deputed staff with reference to (a & b) above, as prescribed by the University and as per tender document. 8 CPWD DSR (E&M) 2022/Chapter-01: Wiring.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 5,00,000/- 9 CPWD DSR (E&M) 2022/Chapter-02: MCCB, MCB, DBs.The bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 10 CPWD DSR (E&M) 2022/Chapter-05: EarthingThe bidder has to quote the rates above / below / at par on DSR (E&M) 2022 rates (including all) considering estimated cost of work Rs. 1,00,000/- 11 Detection of fault in underground electric Low Tension (LT)/High Tension (HT) cable incl. fault detection machine charges, digging & labour charges etc. complete in all respects as per standard practice. 12 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor LT cable of 1.1 KV grade as required. 13 3½ X 25 sq. mm 14 3½ X 35 sq. mm 15 3½ X 50 sq. mm 16 3½ X 70 sq. mm 17 3½ X 95 sq. mm 18 3½ X 120 sq. mm 19 3½ X 150 sq. mm 20 3½ X 185 sq. mm 21 3½ X 240 sq. mm 22 3½ X 300 sq. mm 23 3½ X 400 sq. mm 24 4 X 16 sq. mm 25 Supplying and making straight through cable jointing with heat shrinkable jointing kit complete with all accessories including ferrules suitable for following size of 3 core, XLPE aluminium conductor HT cable of 11 KV grade as required : 26 70 sq. mm 27 120 sq. mm 28 185 sq. mm 29 240 sq. mm 30 300 sq. mm 31 400 sq. mm 32 General inspection & patrolling of about 10 km long overhead HT/LT lines feeder wise for identification of maintenance work to be carried out i/c strengthing of cross arms with clamps including tightening of nut bolts, removal of birds nest and foreign material from line along with tree/bush trimming under these lines. (to be carried out before starting of summer season and as per the requirement). 33 Annual Servicing of Fans (Ceiling/Exhaust/Wall/Pedestal etc.) installed in various buildings of the University i/c checking the unit with accessories for functionality tests, replacement of nut-bolts & locking pins/clips wherever reqd, oiling/greasing, cleaning, pasting of service/repair slips on fan and any other minor repair works required on site i/c labour, tools & takels charges as per standard practice and directions of EIC. Note: 1) This work also includes replacement of spare parts of fans like condensors, regulators, fan hooks as required during servicing and these spare parts will be provided by the University.2) This work excludes all major repair works like rewinding, replacement of bush/bearing etc. 34 Copper rewinding of existing burnt fans (Ceiling/ Exhaust/Wall/Pedestal Fans) under buyback of old copper incl. handling charges etc. as per standard practice. 35 Replacement of parts like bush/bearing etc. with new one of same size/rating under buyback of faulty one as per standard practice incl. handling charges. 36 Repairing of rotor/stator/shaft etc. of fans as required as per standard practice incl. handling charges. 37 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj 38 Comprehensive AMC Work of Online UPS(s) of different ratings installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects excluding replacement of batteries.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 39 14 Nos. 1 kVAOnline UPS 40 08 Nos. 2 kVA to 3 kVA Online UPS 41 08 Nos. 5 kVA to 6 kVAOnline UPS 42 02 Nos. 10 kVA Online UPS 43 06 Nos. 15 kVA to 20 kVA Online UPS 44 02 Nos. 40 kVA Online UPS 45 Replacement of following capacity faulty/dead SMF rechargeable batteries with new batteries of same rating/capacity along with connections, testing and commissioning etc. as required on site as per standard practice, under buyback offer. Make: Exide/Amaron/Luminous/HBLWarranty:minimum 02 years onsite or as per OEM, whichever is higher. 46 18 AH, 12 V 47 26/28 AH, 12 V 48 42/45 AH, 12 V 49 65 AH, 12 V 50 75 AH, 12 V 51 120 AH, 12 V 52 150 AH, 12 V 53 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj 54 Comprehensive AMC Work of 86 Nos. Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects.Note: This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons. 55 Repairing of 45 Nos. faulty Water Coolers of 150 LPH capacity each, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 56 SH-II (d) Comprehensive AMC Work of HVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURajComprehensive AMC Work ofHVAC System (Ductable / VRV-VRF / Cassate / Split / Tower / Window Type Air Conditioners and ETAC System) installed in various buildings of CURaj, including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 57 100 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in CIL Building. Make: Hitachi 58 40 hp rated inverter technology based VRV/VRF type Air Conditioning System installed in VCS, Admin Building. Make: Hitachi 59 04 Nos. 11.0 TR capacity Ductable Air conditioning units with Scroll Compressor with R 410 A Refrigerant, vibration isolators etc. complete. Make: Hitachi 60 03 Nos. 5.5 TR capacity Ductable Air conditioning units with Scroll Compressor, R 410 A Refrigerant, vibration isolators etc. complete. Make: Carrier 61 03 Nos. Ceiling-mounted 3.0 TR Cassette Air Conditioning units complete. Make: Bluestar 62 400 Nos. Window/Split/Tower type air conditioners. 63 02 Nos. 30000 CFM, Air ducting system (ETAC) 64 04 Nos. 28000 CFM, Air ducting system (ETAC) 65 02 Nos. 10000 CFM, Air ducting system (ETAC) 66 02 Nos. 4000 CFM, Air ducting system (ETAC) 67 Repairing of faulty 100 Nos. Split ACs, 10 Nos. Tower Air-conditioners and 01 No. 5.5 TR Ductable AC, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 68 SH-II (e) Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets at CURaj. 69 Comprehensive Annual Operation, Repair and Maintenance of 04 Nos. 11/0.433 kV electric sub-stations and 05 numbers DG Sets along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower for operational purpose, labour, machinery, spare parts, Control Panel/DG Set Batteries, consumables, tools & plants etc. complete in all respects, as per standard practice and directions of Engineer-in-Charge.Note: 1) This work includes operators in all three shifts on 24*7*365 basis at each ESS.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing i/c all B/C/D checks and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 70 SH-II (f) Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts at CURaj. 71 Comprehensive Annual Operation (in general shift), Repair and Maintenance of 14 nos. Johnson make, machine room less passenger lifts along with associated panels etc. through OEM/Authorized Service Agents of OEM only, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note:1) This work includes one lift operator in general shift on 24*7*365 basis in Admin Building.2) This work includes general R&M on monthly basis, preventive R&M on quarterly basis, annual servicing and unlimited breakdown calls through qualified & experienced persons, as per OEM’s standard guidelines & service manuals. 72 SH-III Comprehensive Annual Repair & Maintenance Work of Fire Hydrant System and Fire Alarm System installed at CURaj. 73 Comprehensive Annual Repair & Maintenance Work of all Fire Hydrant System installed in various building of the University (tentative buildings = 30 nos.) as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 74 Comprehensive Annual Repair & Maintenance Work of all Fire Alarm System and associated equipment installed in various building of the University as specified in Schedule of Work, including manpower, labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice.Note: This work includes general R&M on monthly basis, preventive R&M and servicing on quarterly basis and unlimited breakdown calls through qualified & experienced persons. 75 Repairing of existing non-functional Fire Hydrant System including associated equipment, installed in B1 to B7 Hostel buildings, KV Building and B/C/D type Staff Quarter Blocks of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 76 Repairing of existing non-functional Fire Alarm System including associated equipment, installed in various buildings of CURaj including labour, machinery, spare parts, consumables, tools & plants etc. complete in all respects, as per standard practice before starting the CAMC of faulty equipment. 77 SH-IVComprehensive Annual Maintenance Contract for RO Plants/Purifiers. 78 The scope of work includes comprehensive annual maintenance and servicing of RO Plants/Purifiers and submitting a report after every visit. The scope of work includes checkup of each Unit/system and general cleaning, chemical cleaning of cartridge, if required, replacement of all type of membrane, all type of filters, all pipes, S.V., TDS Controller, all type of sensors, pump etc. as per requirements of the University during the CAMC Period. 79 Supply and Installation (under buy back) of Reverse Osmosis Plant of 50 LPH Capacity Make Eureka ForbesNote: Old Reverse Osmosis Plant of 50 LPH Capacity - Make Eureka Forbes will be the property of the Contractor. Hence contractor may be advised to quote their rates accordingly. 80 SH-VComprehensive Operation and Maintenance of IT Works. 81 Comprehensive Operation and Maintenance of installations IT Works (Operation & CAMC of Audio & Video Conferencing System, Networking items for LAN and Wi-Fi systems like Switches, Active & Passive network components, Smart class rooms Equipments including PA systems, Hardware and software maintenance of Computers, Laptops, Printers, Projectors, Servers), CCTV Systems. as per the details given below: 82 Hardware Items 83 Laptops : 84 Desktop System: 85 Server: 86 Printers: 87 LCD Projector: 88 CCTV System 89 IP Camera 90 DVR Camera 91 Switch (24 port) 92 Switch (8 port) 93 Switch (4 port) 94 42 Screen 95 32 Channel NVR 96 8 Channel NVR 97 4 Channel NVR 98 Surveillance Hard Disk 10 TB 99 Surveillance Hard Disk 4 TB 100 Surveillance Hard Disk 2 TB 101 Biometric Access Control Systems 102 Face Biometric Machine 103 Voice System 104 IP-PBXMachine 105 IP Phone 106 IP Phone DSS KEY 107 Data Networking System 108 Switch(48 Port) 109 Switch (24 Port) 110 Core Switch 111 LAN points 112 Audio Video Conferencing System 113 Group Video Conferencingdevice including camera, speakerphone with USB plug-and-play connectivity 114 PTZ Video Conferencing Camera 115 Smart Classrooms System including PA System 116 Smart Classroom equipped with, interactive screen 75/86 inch, audio systems, digital podium with mini PC, PTZ cameras and other related items 117 SH-VI Comprehensive Maintenance of Horticulture and operation & maintenance of Drip Irrigation System. 118 Horticulture Manpower in General Shift in all days except Sundays and holidays (Unskilled). All tools tackles shall be arranged by contractor within its quoted rates.• Complete maintenance of Trees, Plants and peripherals, shrubs, hedge, lawns, (Including cricket ground, hockey ground and football ground etc.) cemented potted plants, flower beds, creepers etc. within the campus of the Central University of Rajasthan.• Maintenance includes weeding, pruning, gap filling, watering, mowing of lawn, hoeing, hedge-clipping, application of insecticide & pesticide, top dressing of lawn with good earth and manure including other maintenance work as directed by the University from time to time.• Fertilizers, Manures, plant protection materials etc. will be provided by the contractor nothing extra shall be paid in this regard.Maintenance of Drip Irrigation System, (water sprinkler system installed at cricket, football and hockey grounds and another places of the University etc.) periodical checking of the system cleaning, oiling, greasing, routine maintenance, realignment, necessary safety arrangements & repair/ replacement of consumables such as Super flow screen filters, Gravel filters, Pressure relief valve, Non return valve, stainless steel pressure gauges,by pass valve PP, PVC control/ball valves, sub main flush valve, Reinforced nylon air release valve CPVC gate valves, super flow disc clean filters, PVC pipes and fittings etc. as per direction of Engineer-in-charge. This shall include all cost involved in maintenance except for electricity for operation, which shall be provided by the University free of cost. 119 SH-VIIMechanized Housekeeping Services, Garbage Collection & Disposal Services, and Pest Control Services at CURAJ. 120 ProvidingMechanized House Keeping Service include machine enabled cleaning, sweeping, wiping, dusting, moping, freshening, garbage collection, segregation & disposal, vacuum cleaning, scrubbing and any other similar tasks as assigned by CURAJ authorities from time to time.Consumable, like duster, Soap, chemicals, wipers, Phenyl and other cleaning materials for toilets and floor required as indicated in list under the scope of work etc.All façade glass should be cleaned once in a month including glass doors and windows.Providing pest Control Services, Rodent Control Services, Fogging & Fumigation against mosquito & larva, Fly management services, termite treatment etc. as per tender terms and conditions and directions of the University. 121 Termite Treatment: Termite treatment in the University based on IS:6313(Part-3)-1981 specification which consists of creating uninterrupted chemical barriers inside and all around the building. The treatment should be drill holes of 6mm as close as possible to the plinth, walls, junctions of the walls at an interval of 6 inches enough to reach the soil below 6 inches deep. Then chemical emulsion should be injected into these holes, which should be subsequently sealed using white cement match with floor colour all complete , The wall should be spray the chemical emulsion up to roof height wherever required complete. 122 SH-VIII Hiring Manpower with fixed remuneration through outsourced agency at CURaj. 123 Service charges per month per person(To be quoted for deciding the lowest responsive bid to award the work)
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 2
8.
Defence #9528620 AOC
Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the rate shall be quoted by the bidder. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units including indoor and outdoor unit complete of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 BLANK 24 BLANK 25 BLANK 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 100 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 400 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No.(iii) Aluminium Bus bar TPN - 600 amps- 1setOUTGOING(i) MCCB 3 Pole 200 amp 50 Hz, 415 V with rupturing capacity 35 KA with microprocessor based release- 02 No.(iii) MCB TPN 32 Amp - 03 Nos.(iv) 80 HP S/D soft STARTER- 02 Nos.(v) DOL STARTER 7.5 HP- 02 Nos.(vi) Motor Protection Relay32-88 amps- 2 nos. (vii) Motor Protection Relay2- 5.5 amps- 2 nos. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 4 Nos. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 6 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply and fixing single unit flame type detectors (Triple IR infrared flame detectors) Addressable type Flame detectors with UV/IR detection capacity (add up cost of module to be a complete set, the type of module shall be relaying type module) complete all as specified and directed 78 Supply and fixing,Test and Drain valve 65/50mm, forged brass body, brass chrome plated ball, 304SS stem with Polycarbonate sight glass, indicator and handle made of steel complete all as specified and directed 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Double mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on rails at the bottom to traverse the length of the storage system. Top rails mounted on the racking system shall also support it. PMDC motars should be used with required counter weight for better efficiency of verticle travel.General technical parameters of stacker crane:Technical parameters/Type- Double Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system:- Two single aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelDouble mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system during the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASR system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1)Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane. An additional antifall device must be provided for the lifting carriage. In the event of electromagnetic break motor failure or malfunction, this device should automatically engage to safely hold the carriage and prevent any freefall, thereby avoid accidents due to emergency brake failure.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASR system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: 1) Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integrated. Changes in make of different components of ASR system and minor changes in different parameters are permitted with approval of Accepting Officer as per recommendation of ASR system manufacturerprovidedthe end objective of the system is complied.2) The ASR system is to be installed in Bulk store house complex. Necessary civil works for installation of the ASRS required in the building is included in the scope of this item. Neccessary arrangements for integration of system with flooring and overhead trussess of the building shall be done at appropriate stage and shall be included in the rates quoted3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptanceMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advanced Inventory Management System with compatibile computer hardware and integrated inventory and weight management system with PLC based software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height(Min) : 6400 (±100) mm(ii) System Width(Min) : 3150 (±100) mm(iii) System Depth(Min) : 2300 (±100) mm(iv) System Base(Min) : 7.24 Sq.Mtr(v) Tray Int. Size(Min): 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight(Min) - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 Kg(Min)Technical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(Min)(x) Storage surface area per system - 39.2 sq mtr(Min)(xi) Door - Automatic, (xii)Power supply - 440V, 50/60 Hz, 3 Phase(xiii) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xiv) Chain - Diamond makeor equivalent, (xv)Bearing - SKF/NTN make or equivalent(xvi) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: 1) The system and software provided under this item shall be of same make as for item 13.066 to 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system.2) Comprehensive maintenance of the system during two years of defect liability period shall be a part of this item and rates shall be quoted accordingly. Comprehensive maintenance shall include all spares including software update. The ASR and advanced management system shall be operated by single warehouse management system.3) The PLC program backup for the ASRS and Advanced Inventory Management System shall be provided in an editable format. The WMS program shall be provided along with its source code to enable the user to perform maintenance, modifications and future upgrades as part of the project acceptance 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS, 100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCB, TPN 40 Amp, 415 Volt, C Curve - 03 Nos.(b) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(c) Digital ammeter - 2nos.(d) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV / 0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro/Bajaj 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing and commissioning of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 MMake: Precitech thermal Pvt. Ltd., Rram Buisiness corp, Alfa therm Ltd., Thermax Ltd, Kanti Industries, Fortec 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a) Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories: Diesel engine of rated speed at full load electric start developing with system with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(b) Radiator with blower fan or heat exchanger with guard.(c) Pipe coupling for engine cooling system piping.(d ) Corrosion inhibitor coolant(e) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(f) Fly wheel housing and fly wheel to suit alternator.(g) Engine bearing mechanism in fly wheel housing.(h) Shut off coil with safeties for LLOP/HWT/over speed.(i) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Battery charging alternator.(m) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(n) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet of30 gauge for the entire length of exhaust pipe.(o) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(p) Interconnecting copper cabling of adequate capacity batteries control.(q ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(r) Self starter 24 volts DC.(s) Electric operated electronic governor.(t) Fuel injection pump.(u) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(v) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (w) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(x) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(y) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, inlet arrangement for diesel filling for exterior canopy (without opening its panel) etc complete all as specified and directed.(z) Isolator panel with 630 amp MCCB(aa) Auto logic panel for automatic stat(ab) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof, insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(ac) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(ad) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (ae) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(af) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No. EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(i) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(ii) Bottom gland plate for incoming and outgoing cables.(iii) Circuit diagram plate.Note:- DG set should be as per CPCB- 4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981.The contractor shall procure the item within the period given by CPBC in case of revision in CBPC norms. Nothing extra will be paid on account of delay from the part of contractor. DG set shall have an exhaust with stack height of minimum 2m from the top of generator with a cowl. Smoke released from the exhaust of the DG sets indicating that emission parameters are within permissible limits, as prescribed by CPCB, demonstrating compliance with emission limits prescribed by CPCB 2016. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 set(d) Horizontal aluminium bus bar for 3 phase 440 V, 50 Hz, 4 wire system of rating 800 Amps for phases and 800 Amps for neutralOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 03 No. (for Package AC Bulk Store, pump house and fire pump & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The Energy Meter to be capable of running in both prepaid and postpaid mode.(b) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 155 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Initial load test (pull outtest as per design load) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 158 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 159 Testing of piles Initial load test (verticle load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed 160 M & L for carrying out Initial Load test (lateral load test) cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note:- Providing and installing test piles shall measured and paid separately) 161 M & L for carrying out Initial load test (pull outtest as per design load)of cast in situ piles of 450 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 162 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 450 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed
Contract Date: Feb 11, 2026 Contract Value : 59.27 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
9.
Housing Urban and Rular Development #8979082 Technical Bid
Tender For Electrical Work - &P 2 Fire Fighting Work Fire Pumps And Accessories: Supplying, Installation, Testingand Commissioningof Electric Driven Main Fire Pump Suitablefor Automatic Operationandconsistingoffollowing, Completeinall Respects, As Required :A ) Horizontal Type, Multistage, Centrifugal, Split Casing Pump Of Cast Iron Body & Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.C ) Suitable Hp Squirrel Cage Induction Motor, Tefc, Synchronousspeed1500rpm, Suitableforoperation On415volts, 3Phase50hz, Acsupplywithip55 Protectionforenclosure, Horizontalfootmountedtype With Class-F Insulation, Conforming To Is-325.D ) M.S. Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. E ) Suitablecementconcretefoundationdulyplastered With Anti Vibration Pads. F ) 2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 3 Supplying, Installation, Testingandcommissioningof Diesel Engine Driven Main Fire Pump Suitable For Automatic Operation And Consisting Of Following, Complete In All Respects, As Required : ( Diesel Driven Pump ) A ) Horizontal Type, Multistage, Centrifugal Pump Of Cast Of Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is 1520.B ) Suitablehp, 1500Rpmwatercooledwithradiator, Diesel Engine Conforming To Relevant Is Standard Completewithautostartingmechanism, 12 / 24Volts Electricstartingequipment, Dieseltank, Exhaustpipe Extended Upto 10 M Outside Pump House Duly Insulated With 50 Mm Thick Glass Wool With 1.0 Mm Thick Aluminium Sheet Cladding, Residential Silencer, Instruments And Protection As Per Standard Specification, Stop Solenoid For Auto Stop In The Event Of Fault With Audio Indications, Painted With Post Office Red Colour Etc. As Required. C ) M.S Fabricated, Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required. D ) Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.2850 Lpm At 70 M Headnote: * The Head Of The Pump Is Selected In A Manner Soastogivea Minimum 3.5Kgf / Cm 2 Pressureat The Highest / Farthest Point. 4 Supplying, Installation, Testingandcommissioningof Electricdrivenpressurisationpumpsuitablefor Automaticoperationandconsistingoffollowing, Complete In All Respects, As Required : ( Jockey Pump ) A ) .Horizontaltype, Multistage, Centrifugalpumpofcast Iron Body And Bronze Impeller With Stainless Steel Shaft, Mechanical Seal Conforming To Is : 1520. B ) .Suitablehpsquirellcageinductionmotortefctype Suitableforoperationon415volts, 3Phase50hz Ac Supply With Ip 55 Class Of Protection For Enclosure, Horizontalfootmountedtypewithclass-FInsulation, Conforming To Is : 325. C ) .M.S.Fabricated Common Base Plate, Coupling, Coupling Guard, Foundation Bolts Etc. As Required.D ) .Suitablecementconcretefoundationdulyplastered And With Anti Vibration Pads.180 Lpm At 70 M Head 5 Control Panels: Fabrication, Supply, Insallation Testing & Commissioning Of Electrical Control Panel Of Cubical Construction, Floor Mounted Type, Fabricated Out Of 2Mm Thick Crca Sheet, Compartmentalisedwithhingedlockabledoors, Dustandverminproof, Powdercoatedofapproved Shade After 7 Tank Treatment Process, Cable Alley, Inter-Connection With Suitable Sizecopperconductor Cable / Solidcopper Strip, Havingswitchgears And Accessories, Mountings And Internal Wiring, Earth Terminals, Numbering Etc. Complete In All Respect, Suitableformainfirepump, Pressurisationpump& Dieselpumpsetcompleteaspercpwdspecification Withfollowingincomingandoutgoings, Suitablefor Operationon415v, 3Phase, 50Hzacsupplywith Enclosure Protection Class Ip 42 As Required :Incomings:A ) 630A, 50Ka4 Pole Mccb, Ics=100% Icu Rating Digital Voltmeter 0-500V With Selector Switch Ammeter ( 0-630 A ) With Selector Swtich & Cts Etc.B ) Ledtyperybphaseindicatinglamps, On, Off, Trip Indicating Lampsset Of Copperbus Bar 800Ampsoutgoings: Main Fire Pump :200Amp, 50Katpnmccb, Ics=100%Icu, Withfully Automatic Star / Delta Starter Suitable For 75 Hp Pump With Overloadprotection, Currentsensingtypesinglephase Preventorcompletewithallacceessoriesandinternal Wiringrequiredforautomaticoperation, Selectorswitch For Local / Remote, Auto / Manual / Off Operation. - 2 Setsjockey Pump:100 Amp, 50Ka Tpn Mccb, Ics=100% Icu, With Suitable Hp Fully Automatic Star / Delta Starter With Overload Protection, Currentsensingtypesinglephasepreventor Complete With All Acceessories And Internal Wiring Requiredforautomaticoperation, Selector Switchfor Local / Remote, Auto / Manual / Off Operation. - 2 Setsdiesel Engine Controla ) Control For Diesel Engine Comprising - Automatic / Manualselctorswitch&3Attemptsstarting Device, Timersandrelaysasrequired, Pushbuttons, Start / Stop In Manual Modeb ) Indicatinglampforhigh / Lowlub.Oilpressure, High Water Temp And Engine On Indicationc ) Batterychargersuitbalefor12v / 24Vdcwithboost And Trickle Selector Switch, 0-30 V Dc Volt Meter, And 020 A Dc Ammeter All Standard Relays And Accessories For Automatic Operation Of Diesel Engine.System Controller: Designing, Supply, Installation, Testingand Commissioning Of System Controller To Control Operation Of Main Electric Fire Pump, Diesel Pump, Pressurization Pump, Terrace Pump In Sequence As Per Specification Consisting Of Relays, Timers. Sensors, Annunciation Windowforfaultindication, Complete As Per Specification 6 Providinglaying, Testing&CommissioningofCClass Heavydutymspipeconformingtois1239 / 3589I / C Fittingslikeelbows, Tees, Flanges, Tapers, Nutsbolts, Gasketsetc.Ingroundincludingwelding, Excavation& Providingcementconcreteblocksassupports, Anticorrosivetreatmentwithcoaltar / Asphalttapeasper Is10221, Refillingthetrenchetc.Offollowingsizes Complete As Required. 200 Mm. Dia ( Wall Thickness = 6.3 Mm ) 7 150 Mm. Dia 8 Providing, Laying, Testing&Commissioningof CClass Heavydutymspipeconformingtois3589 / Is1239 Includingwelding, Fittingslikeelbows, Tees, Flanges, Tapers, Nuts Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Or More Coats Of Synthetic Enamel Paint Of Required Shade Complete As Required : 25 Mm Dia 9 32 Mm Dia 10 40 Mm Dia 11 50 Mm Dia 12 65 Mm Dia 13 80 Mm Dia 14 100 Mm Dia 15 150 Mm Dia 16 Providing, Laying, Testing&CommissioningofBClass Heavydutyg.I.Pipeconformingtois1239including Welding, Fittings Like Elbows, Tees, Flanges, Tapers, Nuts, Bolts, Gaskets Etc. And Fixing The Pipe On The Wall / Ceiling With Suitable Clamp / Support Frame And Painting With Two Ormorecoatsofsyntheticenamelpaintofrequired Shade Complete As Required: 25 Mm 17 32 Mm 18 40 Mm 19 50 Mm 20 65 Mm 21 80 Mm 22 100 Mm 23 150 Mm 24 Supplyingandfixingsingleheadedinternalhydrant Valve With Instantaneous Gunmetal / Stainless Steel Coupling Of 63 Mm Dia With Cast Iron Wheelisi Marked Conformingtois5290 ( Type-A ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 25 Supplying And Fixing Single Headed External Yard Hydrant Valve With 1 No. 63 Mm Dia Instantaneous Fm Gunmetal / Stainlesssteel Couplingand Cast Iron Wheel, Isimarked, Conformingtois5290 ( Typea ) Withblank Gunmetal / Stainless Steel Cap And Chain As Required :Single Headed Gunmetal 26 Supplying, Fixing, Testing And Commissioning Of Butterfly Valve Of Pn 1.6 Rating With Bronze / Gunmetal Seat Duly Isi Markedcompletewithnuts, Bolts, Washers, Gaskets Conforming To Is 13095 Of Following Sizes As Required :80 Mm Dia 27 100 Mm Dia 28 150 Mm Dia 29 Supplying, Fixing, Testing&Commissioningofdouble Flangedsluicevalveofratingpn1.6Withnonrising Spindle, Bronze / Gunmetalseat, Isimarkedcomplete With Nuts, Bolts, Washers, Gaskets And Conforming To Is 780 Of Following Sizes As Required : 80Mm Dia 30 100Mm Dia 31 150Mm Dia 32 200Mm Dia 33 250Mm Dia 34 Supplyingandfixingorificeplatemadeoutof6mm Thick Stainless Steel ( Grade 304 ) With Orifice Of Required Sizetobefitted Betweenflange&Landingvalveof Externalandinternalhydrantstoreducepressureat The Outlettothe Levelof 3.5Kg / Cm2 Complete As Required. 35 Providing, Installation, Testingandcommissioningof Non-Returnvalveoffollowingsizesconfirmingtois: 5312 Complete With Rubber Gasket, Gi Bolts, Nuts, Washers Etc.As Required.100Mm Dia 36 150Mm Dia 37 200Mm Dia 38 Providing, Installation, Testingandcommissioningof Stainlesssteely-Strainerfabricatedoutof1.6Mm Thickstainlesssteel, Grade304, Sheetwith3mmdia Holes With Stainless Steel Flange.150Mm Dia 39 200Mm Dia 40 Supplying And Fixing 63 Mm Dia, 15 M Long Rrl Hose Pipewith63mmdiamaleandfemalecouplingsduly Boundwithgiwire, Rivetsetc.Conformingtois636 ( Type-A ) As Required : Gun Metal 41 Supplying Andfixing First-Aidhosereelwithms Constructionspraypaintedinpostofficered, Conformingtois884completewiththefollowingas Required. A ) . 20Mmnominalinternaldiawaterhosethermoplastic ( Textile Reinforced ) Type -2 As Per Is: 12585 B ) .20Mmnominalinternaldiagunmetalglobevalve& Nozzle. C ) .Drum And Brackets For Fixing The Equipmets On Wall.D ) .Connections From Riser With 25 Mm Dia Stop Gun Metal Valve & M.S. Pipe And Socket. E ) .40 M 42 Supplying & Fixing 63 Mm Dia Gun Metal Short Branch Pipe With 20 Mm Nominal Internal Diameter Sizenozzle Conforming To Is 903 Suitable For Instantaneous Connection To Interconnect Hose Pipe Coupling As Required : Gun Metal 43 Supplyingandfixingoffirebrigadeconnectionof Cast Iron Body With Gun Metal Male Instantaneous Inlet Couplingscompletewithcapandchainasreqd.For Suitabledia Ms Pipe Connectionconforming To Is 904 As Required :2 Way-100 Mm Dia M.S. Pipe 44 4 Way - 150 Mm Dia M.S. Pipe 45 3 Way - 150 Mm Dia M.S. Pipe 46 Supplying And Fixing Air Vessel Made Of 250 Mm Dia, 8 Mm Thick Ms Sheet, 1200 Mm In Height With Air Release Valveontopandflangedconnectiontoriser, Drain Arrangementwith25mmdiagunmetalwheelvalve Withrequiredaccessories, Pressuregaugeand Paintingwith Synthetic Enamel Paint Of Approved Shade As Required. 47 Providing, Fixing, Testing & Commissioning Of 15Mm Dia Quartzoidbulbtypesprinklersofrating68degree Centigrade With Required Accessories :Pendent Sprinkler 48 Upright Sprinkler 49 Horizontal Side Wall Sprinkler 50 Concealed Sprinkler 51 Providing & Fixing Of Pressure Switch In M.S. Pipe Line Including Connection Etc. As Required. 52 Providing& Fixingflowswitchinfollowingsizesm.S. Pipe Including Connection Etc As Required. 53 100Mm Dia 54 150Mm Dia 55 Providing, Fixing, Testing & Commissioning Of Installationcontrolvalveofcastironbody, Brass / Bronzeworking Partscomprisingofwater Motor Alarm, Bronzeseatclapper, Clapperarmand Hydraulicallydrivenmechanicalgongbelltosound Continuousalarmwhenthewetriser / Sprinklersystem Activates, Pressuregauges, Emergencyreleases, Strainer, Pressureswitch, Cockvalvecompletewith Drainvalveandbypass, Testcontrolbox, Ballvalves, Ms Pipe Of Required Size, Flanges, Orifice Plate, Gasket Etc Of Follwing Sizes Asrequired : 150Mm Dia 56 Supplying, Installation, Testing & Commissioning Of Sprinklerflexiblepipe ( Ullisted ) Ofstainlesssteel Complete With 15 Npt On Reducer Thread With Maximum Working Pressure Of 175 Psi Test Pressure Of 875Psi ( Burst ) Withbranchline ( Inlet ) 25Mmnpt Malethreadtosprinklerhead ( Outlet ) 15Mmnpt Femalethreadwithreducer, Nipple, 2Sidebrackets, Center Bracket, Stockbar Of Following Sizes Complete As Required.700Mm 57 1000Mm 58 1200Mm 59 1500Mm 60 Providing And Fixing In Position The Industrial Type Pressure Gauges With Gun Metal / Brass Valves Complete As Required ( E&M ) 61 Providing And Fixing Ms Cabinet ( Size 750X600x250 Mm ) Fabricated From 16 Gauge Ms Sheet With Full Front Glass Door & Locking Arrangement For Pad Lockwith Suitable Shelves For Keeping 25 Nos. Spare Sprinklers & One No. Spanner Properly Fixed In Shelves. Cabinet Shall Be Painted With Enamel Paint Of Approved Shade. ( Cost Shall Include 20 Nos. Spare Sprinklers ( 5 Nos Side Wall 20Nos Pendent, One No. Spanner And 5 Rolls Of Teflon Tape ) . Note: All Valves Shall Be Of Pn16 Rating 62 Portable Fire Extinguishers: Providing & Fixing Of Isi Marked ( Is:15683 ) Portable Fire Extinguisher, Carbondioxide Type Flat Base Including Valve, Discharge Hose Of Not Less Than 10 Mm Dia. 1 M Long & Complete In All Respects Including Initial Fill With Co2 Gas Confirming To Is:307-1966 Filled To A Filling Ratio Of Not More Than 0.667 Of Not More Than 0.667 And Wall Suspension Bracket Capacity 4.5 Kg 63 6 Kg. Abc Powder Type Fire Extinguishers Are Manufactured And Marked To Indian Standard Is: 15683. Suitable First Aid Appliance For Fighting Fires In Class A, B & C Fire That Is Wood, Textile, Flammable Liquids & Gases. 64 Providing And Fixing Mechanical Foam Type Fire Extingushers Consisting Of Welded M.S. Trolley Mounted Cylindrical Body, Squeeze Lever Discharge Valve Fitted With Pressure Discharge Hose, Discharge Nozzle, Trolley Etc., Isi Marked As Per Is:Is:13386 Finished Externally With Red Enamel Paint.Capacity 50 Lit ( D.G.Room ) 65 Providing And Fixing Carbon-Di-Oxide Fire Extingushers Trolley Mounted With All Accessories Internal Discharge Tube, High Pressure Discharge Hose, Discharge Nozzle, Isi Marked As Per Is:2878 Finished Externally With Red Enamel Paint. Capacity 22.5 Kg. 66 Boq-D: Plumbing Pump & Equipmentswater Supply, Drainage, Pumps & Equipment :Providingand Fixing Centralized Water Level Controller Cum Indicator System, As Per The Following Details:Centralised Plc Control Panel : Along With Touch-Screen Display Board ( Min. 8 Diag. Size ) Along With All Accessories For Complete Controls & Indication. Panel Shall Be Made Out Of Crca Sheet Min. 2Mm Thick Having Necessary Interlocks, I / OS, Required Number Of Repeater Amplifiers, All Audio-Visual Alarms As Required Specifications As Listed Below. An Emergency Stop Push Button Shall Be Provided In The Panel. The Panel Shall Have Modbus Compatibility For Seamless Bms / Bas Integration And Shall Be Of Approved Make. The Complete System Control Matrix, Wiring Diagram, SldS And Technical Details Shall Be Submitted By The Vendor And Gotten Approved Before Commencement Of Execution Of Works. Water Level Indicators Cum Controllers :Working On Hydrostatic Pressure Measurement Principle Made Of Stainless Steel For Installation On Storage Tanks, And Capable Of Providnig 4 To 20 Ma Analog Signal Compatiblewith Plc Signal Inputs And Completeas Per Working Requirements For Details Of Equipment Below. All Control Outputs To Mcc Panel Shall Be Included As Per Requierments. A ) .Fire Static Underground Tanksb ) .Real-Time Water Level Indication Monitoring 67 V. Low Level Audio-Visual Alarm At Less Than 25% Total Capacity.Raw Water Underground Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Tubewell Pumps At 35%Auto Cut-Out Of Tubewell Pumps At 95% 68 Auto Cut-Out Of Raw Water Pumps At 35%Domestic Water Underground Tanks Real-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Auto Cut-In Of Raw Water Pumps At 35% 69 Auto Cut-Out Of Domestic Water Pumps At 35% Flushing Water Underground Tanks At Stpreal-Time Water Level Indication Monitoringv. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity.V. High Level Audio-Visual Alarm At More Than 100% Total Capacity.Auto Cut-In Of Raw Water Pumps ( From Stp ) At 35% 70 Auto Cut-Out Of Flushing Water Pumps At 35% Domestic Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 71 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. Flushing Water Overhead Tanksreal-Time Water Level Indication Monitoring V. Low Level Audio-Visual Alarm At Less Than 30% Total Capacity. 72 V. High Level Audio-Visual Alarm At More Than 100% Total Capacity. 73 Providing Complete Testing Kit With All Chemicals Complete Suitable For Conducting Test On Water Quality.The Test Kit Shall Be Suitable To Measure Tds, Ph, Hardness, Iron Content And Other Parameters 74 Hydro-Pneumatic Pumping System For Domestic Supply To Fixture ( Toilet Kitchen ) : Providing, Fixing And Testing Of Packaged Type Skid Mounted Hydropneumatic System With Variable Frequency Drive Type Comprising Of : ( I ) Vertical, Inline Multistage Centrifugal Pumping Set With Stainless Steel Ss-304Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iecstandards And Gjl250 Cast Iron Suction& Discharge Casing, Connected To Tefc Ventilated Induction Motor Of2 Pole, 2900Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply. ( Ii ) Pressure Vessel Of Non Corrosivefrp Composite Construction Lined With Nsf And / Or Fda Listed Material, Likehigh Density Polyethylene With Fully Replaceable Polyurethane. Air Cell Burstpressure Of Minimum Of 5 Times The Vessel Operating Pressure And Cycle Tested For 2, 50, 000 Cycles. ( Iii ) Control Panel With Programmable Logic Controller ( Plc ) For Cyclic Operation Of Pumps + Variable Frequency Drive. The Pump Workingsequence Should Change After Every Operation.Contractor Overload Relays And Mcbs Should Confirm To Iec 898 – 1995 / Specifications. Blinking Indications For Pumps Start, Trip, Low Level Trip, Health Supply Should Be Provided In The Panel Along With The Ammeter& Voltmeter. Control Panel Should Also Consist Of Cooling Fan. ( Iv ) Pressure Switches Bellowtypefittedwithmicro Switch And Having Maximum Pressure And Differentialscaleshould Confirming Bs-6134 Standards And Ip55 Protection Class. ( V ) All Required Ball Valves, Non-Return Valves, Flexible Connectors Etc. And All Required Accessories, Heavy Duty S.S 316 Manifold To Make The System Completely Operational As A Skid Mounted System. Ball Valves Tobe Used Should Be Hot Pressed Brass Ot-58Withstainless Steelballand P.T.F.Eseal And O-Ring. Nrvs To Be Used Shouldbewithspringsando-Ring Arrangement. ( Vendor To Submit Performance Curves And Technical Catalog Of The Proposed Model For Review & Information ) Complete Manifold System Shall Be Factory Aasembled & Totally Mounted On A Common Base Frame With Following Duties:Note: Contractor To Note That The Suction Header Is Required To Have Inlet Connection From The Puddle Flange @ Water Tanks And To The Pump Suction. Provision Of Delivery Header Is Required To Have Outlet Connection From The Pumps. Suitable Outlet Flanges From The Delivery Mainfold / Header Shall Be Provided As Required.A.For Domestic Water Supply For Club & Benquet Hall: No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 350 Lpm Each Pump Head: 55 Meters Apx. Hp ( Motors ) : 3 Hp Location : Plumbing Plant Room 75 For Flushing Water Relift Pump :No. Ofpumps :1 ( 1 Working +1 Standby ) Capacity: 250 Lpm Each Pump Head: 55 Metersapx. Hp ( Motors ) : 2 Hplocation : Stp Plant Room 76 Garden Hydrents & Floor Washing Relift Pump:Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty:No. Ofpumps :2 ( 1 Working +1 Standby ) Capacity: 200 Lpm Each Pumphead: 45 Metersapx. Hp ( Motors ) : 4 Hplocation : Stp Plant Room 77 Supply, Installation, Testing & Commissioning Of Continuous Duty Submersible Centrifugal Non-Clogging Drainage Pumps Of Efficiency Of Approved Make Complete With 3 Phase Motor With All Necessary Protection And Mechanical Seal Etc. Complete With All Ancillaries Including Float Type Level Controllers, Electrical Control Panels Fabricatd From 14 Gauge Crca Sheet Volt Meter Ammeter With Selector Switch, Tpmcb, 5 Va Cl : Cts, Phase Indicating Lamps Protected By 2 Amp Sp Mcb, Dol Starter, Necessary Wiring, Cable Alleys, Earthing, Interlocking, Starter With Automatic Float Type Level Controller, Providion Of High Level Alarm, Sequence Timer, Potential Free Contact To Starter For Connection To Bas, Both Pumps May Run Simultaneously At Pre Determind Level. ( 1 Working + 1 Standby ) Vendor To Submit Proposed Pump Model With Duty Curve.A ) . For Wtp & Stp Plant Room Drainage :Flow Rate : 450 Lpm Head : 15 Mtssolid Handling : 100 Mmlocation : Sump Of Basement Purpose : Plant Room & General Area Drainage Moc : Ss Body Ss Impeller & Shaft 78 B ) .For Basement Drainage : Flow Rate : 450 Lpm Head : 15 Mts Solid Handling : 100 Mmlocation : Sump Of Basement Purpose : Basement Area Drainage Moc : Ss Body Ss Impeller & Shaft 79 C ) .Manhole Cover For U.G Tanks And Sumps :Supplying And Fixing C.I. Cover Without Frame For Manholes :560Mm Diameter C.I Cover ( Heavy Duty ) The Weight Of The Cover To Be Not Less Than 108Kg. 80 F ) .Providing And Fixing Stainless Steel Ladder, Wall Mounted Of 4M Height ( App ) For Underground Tanks Complete With Flanged Ends And Inserts ( Removable Type ) Made Of 38Mm / 42Mm Dia 16 G S / S 304 Quality Pipe Made As Per International Quality Standards Of Approved Shape And Size With Non Skidding Stepsat 300Mm Vertical Spacing, Completeas Directed By The Engineer In Charge. 81 Water Treatment Plant: Providing & Fixing Vertical, Inline Multistage Centrifugalpumping Set ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) With Stainlesssteel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibration Elimination Pads Etc. Complete With Base And Frame, Nuts And Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Have Following Duty:A ) .For Club Building Only : No. Ofpumps: 2 ( 1 Working + 1 Standby ) Flow Rate :150 Lpm Each Head : 30 Mtsrequired For : Filter Feed Pump In Plumbing Plant Room ( 1Working + 1Standby ) 82 Providing And Fixing Vertical Pressure Filter With Dual Media Filter ( Comprising Of 600Mm Bed Depth Of Graded Sand Gravel And 600Mm Bed Depth Of Anthracite ) Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge : 150 Lpm Filtration Rate: 17500 Lit. / M2 / H Discharge : 150 Lpm Suggested Dia App.: 0.90 M 83 Activated Carbon Filter ( Domestic Water ) : Providing And Fixing Vertical Activated Carbon Filter Comprising Ofactivated Carbon Filter Media Fabricated From High Performance M.S Plate Of Minimum 8Mm Thick For Shell & 10Mm Thickfor Dished Ends With Top And Bottom Flanged Openings Including Top And Bottom Hub And Lateral Distribution And Collection System Complete With Initial Charge Of Filter Media, Face Piping, Valves, Accessories, Epoxy Painting, Testing And Commissioning Complete. ( Tested To 6 Kg / M2 ) Discharge :100 Lpm Filtration Rate: 15000 Lit. / M2 / H Suggested Dia App.: 0.60 M 84 Providing, Fixing, Testing & Commissioning Of Msep Water Softening Plant ( Suitable For 3 Kg / Sqcm Workingpressure ) Complete With Initial Charge With T-40 Na Resin, Multiport Valve With Built In Ejector For Controlling All Operations ) , Regeneration System And Hdpe Tank, Pressure Gauge At Inlet, Outlet And Back Wash ( Each With Isolation Cock ) , Valves, Fittings And Water Hardness Testing Kit & Associatedworks. Softener Shall Be Suitable For The Following Duty:Note:The Successful Contractor Will Have To Carry Out A Test Of Raw Water From All The Sources Of Water For The Commercial, Residential & Apartment At Their Own Cost From A Reputed Lab As Approved By The Engineer-In-Charge / Consultant. On The Basis Of These Results The Contractor Has To Submit His Shop Drawings, Design Calculations And Specifications Accordingly.Please Note That It Is Ultimately The Responsibility Of The Contractor To Provide Treated Water For Different Use As Per International Standard As Given In The Attached Guidelines. Raw Water Hardness: 500 Mg / Ltreated Water Hardness:100 Mg / L Regeneration Period:12 Hrs.Capacity : 100 Lpm 85 Supplying, Installing, Testing And Commissioning Of Dosing System ( For Domestic Water Treatment Plant ) Consisting Of One Hdpe Tank Of 100 Litres Capacity With A Positive Displacement Diphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240 V / Single Phase / 50 Hz. Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers, Low Level Switch Andinjection Fittings. The Pump Shall Be Speed & Stroke Control Asialmi / Equivalent Make. The Cost Shall Be Inclusive Of Providing Salt For The Testing And Operation Of System Before Handover To The Owner. 86 Plumbing Panel: Design, Manufacture, Assembly, Wiring, Testing At Works And Supply To Site Of Following Panels / Distribution Boards / Switch Boards. The Boards Shall Be Designed And Fabricated As Per General Specifications, Technical Details, Specifications And Notes As Part Of This Tender / Boq And Relevant Bis Codes. ( Any Load Veriation In System As Technical Document Of Manifactureno Cost Shall Be Paid Extra For System Requirments ) Ip Rating: Ip 54 Incomer:1 No. 250 A 25 Ka, 3P Mccb Of Motor Duty - Only Magnetic Release. ( Adjustable Magnetic Release Upto 250A Mccb Or Micro-Processor Based Release Above 250A Mccb ) .Incomer Metering & Indication: A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt.B ) .R, Y, B Phase Indication Lamps ( 110V ) Led Type C ) .Cast Resin Metering CtS For Each Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio D ) .1 No. Digital Vaf + Pf Meter ( 110V ) ( *With / Without Rs 485 Port ) Bus Bars : 400A, Tp, Aluminium Bus Bars Of Electrolytic Grade With Heat Shrinkable Sleeves 25 Ka. Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) .B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer.C ) .110V Control Circuiting D ) .110V Control Supply Healthy Indication ( Led Type ) .Outgoings: A ) .Dol Starter Comprising The Following ( For Upto 2 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) . For 1Hp. ( 2 Nos. ) ( Chamical Dosingpump ) B ) .Type-2 Co-Ordinationc ) . 1 No. Suitable Rated Tp Mpcb, 10Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) . On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) .On / Off Push Buttons G ) Star-Delta Timerh.2 Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy & Of Suitable Burden & Ratio. J ) .Digital Ammeter K ) .On / Off-Trip / A / M Potential Free Contacts For Bmsl ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.B ) .Dol Starter Comprising The Following ( For 3 Hp To 5 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan :A ) For 4 Hp. ( 2 Nos. ) ( For Pump Room Exhaust Air Fan ) B ) Type-2 Co-Ordination C ) 1 No. Suitable Rated Tp Mpcb, 25 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) D ) Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contactse ) On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) F ) 2 Pole A / M Selector Switch For Bms Application G ) Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioh ) Digital Ammeter With Inbuilt Selector Switch I ) Digital Ammeter J ) On / Off-Trip / A / M Potential Free Contacts For Bmsk ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers.C ) .Dol Starter Comprising The Following ( For 7.5 Hp To 10 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) For 7.5Hp. ( 2 Nos. ) ( Raw Water / Filter Feedpump ) B ) . For 6 Hp. ( 2 Nos. ) ( Soft Water Reliftingpump ) C ) .Type-2 Co-Ordinationd ) .1 No. Suitable Rated Tp Mpcb, 10 Ka, With Inbuilt O / L Relay & Inbuilt Spp Feature ( Site Adjustable ) E ) .Suitable Sized 3P Contactor With 2 No & 2 Nc Auxiliary Contacts F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .On / Off Push Buttons ( With Lockable Off ) H ) . Pole A / M Selector Switch For Bms Application I ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioj ) .Digital Ammeter With Inbuilt Selector Switch K ) On / Off-Trip / A / M Potential Free Contacts For Bms L ) .Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. D ) .Star-Delta Starter Comprising The Following ( For 12.5 Hp To 25 Hp Motors ) For Raw Water Pumps / Treated Water Transfer Pump / Flushing Water Transfer Pump / Borewell / Soft Water Transfer Pump / For Pump Room Fresh Air Fan / For Pump Room Exhaust Air Fan:A ) .12.5 Hp. ( 3 Nos. ) ( Tubewells Pump ) B ) .Type-2 Co-Ordinationc ) .1 No. Suitable Rated Tp Mpcb, -----Ka, Without Inbuilt O / L Relay ( Only Magnetic ) D ) .Suitable Sized 3P Contactors ( Star, Delta & Run Contactors ) With 2 No & 2 Nc Auxiliary Contactse ) Suitable O / L Relay With Inbuilt Spp F ) .On / Off / Trip Indication Lamps ( 110V ) ( Led Type ) G ) .2 Pole A / M Selector Switch For Bms Application H ) .Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratioi ) Digital H Inbuilt Selector Switch J ) On / Off-Trip / A / M Potential Free Contacts For Bms K ) Control Wiring Terminals For Auto Operation Through Potential Free Contacts Ofwater Tank Level Controllers. Feeders ( Without Starters ) For Hydronumatic Pump Panels :1 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 10 Hp Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For Sump Pump Panels : 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 15 Hp Sewarage Sump Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. Feeders ( Without Starters ) For R.O Water Booster Pump Panels : 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & With 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp 110V ( Led Type ) For 3 Hp R.O Waterbooster Pump Panel. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Spare Starter Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Starter Feeders:5 Hp Motors, Dol Starter ( 2 Nos. ) ( Spare Feeders ) Spare Motor Feeders ( Without Starters ) With Same Components As Described In Above Written Similar Feeders: 2 No. Suitable Rated 15 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 10 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch. 1 No. Suitable Rated 10 Ka, Tp, Mpcb Without Inbuilt O / L Relay & 1 No + 1 Nc Auxiliary Contacts & On Indication Lamp ( 110V ) Led Type For 5 Hp Feeder. Suitable Rated Cast Resin CtS For Metering On Each Phase, Of Class-1 Accuracy And Of Suitable Burden & Ratio. Digital Ammeter With Inbuilt Selector Switch.Vendor Can Also Consider Integrated Total Co-Ordinated Starter Upto 15Hp.Plumbing Panel As Described Above. 87 Sump Pump Panel ( Upto 5.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. 3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .E ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( Upto 5.0Hp Motors ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering On Y Phase, Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 88 Sump Pump Panel ( For 7.5Hp To 10.0Hp Motor ) : A ) .It Shall Control Two Pumps P-1 And P-2. The Operation Sequence Will Be As Under :B ) .P-1 & P-2 To Stop At L-1 C ) .P-1 To Start At L-2 D ) .P-2 To Start At L-3 ( At L-3 Both Pump Will Be Running ) Audible Alarm At L-4 ( 50 Mtr Range ) .E ) .Hooter For Annunciation ( Solid State Buzzer ) F ) .Where L-1 < L-2 < L-3 < L-4 ( Level Of Water In The Sump ) ( Probes / Sensors To Control Operation ) G ) .There Shall Be Selector Switch To Interchange The Starting Sequence Between P1 & P2. ( Selection Mode ) Important Features : Sump Pump Panel Shall Have Following Essential Features: R, Y, B Phase Indicating Lamps With Backup. Auto / Manual Selector Switch. Starter On / Off & High Level Indications, Digital Ammeters For Both Pumps. Mpcb With Inbuilt O / L & Spp, Dol Starter And Dry Run Protection Suitable For Motors And As Per Details Given Below : Incomer:1 No. Suitable Rated 35 Ka, Tp, Mpcb Without Inbuilt O / L & With 1No + 1Nc Auxiliary Contacts For Total 10 Hp Of Sump Pumps ( Both Pumps Working Simultaneously ) .Incomer Metering & PtS :A ) .415V / V3 / 110V / V3ptS, Cast Resin Type, 3 Phase For Metering & Indications, Suitable Rated 6A, Tp Mpcb Of The Fault Withstand Capacity As Of The Panel On The Primary Side Of Pt & Suitable Rated 6A, Tp Mcb On The Secondary Side Of Pt. B ) .3 Nos. Cast Resin CtS Of Adequate Class, Burden & Ratio At The Incomer Metering.C ) .R, Y, B ( 110V Ac ) Led Lamp & On / Off Indications ( 110V Ac ) Led Type.D ) .Digital Vaf Meter At The Incomer ( 110V ) . Control Transformer & Control Circuiting For Starters / Contactors & Indication Lamps : A ) .1 No. 415V / 55-0-55Vcast Resin Dry Type Control Transformer Of Adequate Va Burden To Take Care Of Load Of All The Contactor Coils. B ) .Suitable Rated 6A, Dp, Mpcb Of The Fault Withstand Capacity As Of The Panel For Control Circuiting For Contactors Coils On The Primary Side Of Control Transformer & Suitable Rated 6A, Dp Mcb On The Secondary Side Of Control Transformer. ( Transformer With Primary Taps At ± 2.5%, ± 5%, 50 Hz, Centre Tap Earthed ) . C ) .110V Control Circuitingd ) .110V Control Supply Healthy Indication ( Led Type ) .Pt Of Adequate Burden Can Also Be Used For Powering Contactor Coils Of Starters And In That Case Control Transformer Can Be Eliminated. Bus Bars : 100A, Tp, Aluminium Bus Bars Of Required Capacity & Ka Rating With Heat Shrinkable Sleeves.Outgoings:Sump Pump Panel ( For7.5Hp To 10.0Hp Motor ) : 2 Sets Suitable Rated 15 Ka, Tp, MpcbS With Inbuilt O / L Relay & Inbuilt Spp Features ( Site Adjustable ) & With 1No + 1Nc Auxiliary Contacts For 5Hp Each Sump Pump Motor & Each Set With The Following:A ) .Suitable Sized 3P Contactor With 2No + 2Nc Auxiliary Contacts B ) .On / Off / Trip Led Indications ( 110V ) C ) .On / Off Push Buttons D ) .2 Pole A / M Selector Switch For Bms Application E ) .Suitable Rated Single Cast Resin Ct For Metering Oneach Phase Of Class-1 Accuracy & Of Suitable Burden & Ratio. F ) . Digital Ammeter G ) .On / Off / Trip / A / M Potential Free Contacts For Bmsh ) .3 Nos. Suitable Water Level Controllers With Three Electrodes ( 110Ac ) The Sump Pump Control Panel Shall Be Complete With All Interconnections, Water Level Controllers & Sensors / Probes, Risers, Internal Wiring, Labels, Terminal Block Etc Complete As Required. 89 Sewage Treatment Plant:Sewage Treatment Plant Based On Mbbr ( Moving Bed Bio Reactor ) Technology :Supply, Installation, Testing And Commissioning Of Package Type Pre-Fabricated Sewage Treatment Plant Based On Mbbr Technology ( Moving Bed Aerobic Bio-Reactor ) Of 65 Kld Capacity Including All Ms Structure, Mechanical, Electrical And Instrumentation Works As Per Technical Specification Mentioned In The Document. The Scope Shall Also Include To Provide The Ss Bar Screen In Grit Screen Chambers, Grease Separator, Primary & Secondary Treatment Of Waste Water, Air Blowers, All Necessary Interconnecting Piping & Valves, Pumps, Dmf And Acf Filters, Chlorinator, Ultravoilet Dis-Infection Unit, Mcc For Operation Of All Motors, All Inter Connecting Power And Control Wiring, Level Controllers & Other Controls, Ms Puddle Flange ( Hot Dip Galvanized After Fabrication ) , Inlet, Outlet, Overflow, Vent, Manhole Cover Etc, Completed In All Respect In Ready To Use And Easy To Transport Condition. ( The Entire System Tobe Installed Above Ground ) .A ) .Nature Of Effluent - Domestic Sewage From Toilets / Kitchen.B ) .Flow Rate - 65 Kld C ) .Sewage Incoming Characteristics D ) .Ph - 6.5 - 8.5 E ) .Bod5 - Upto 250 - 400 Mg / L F ) .S. Solid - 250 To 450 Mg / Lg ) .Cod 5 - Upto 600 Mg / L H ) .Oil & Grease - 50 Mg / L I ) .Effluent Discharge Standard After Treatment J ) .Ph - 6.5 - 7.5K ) .Bod5 - Less Than 10 Mg / L L ) .S. Solids - Less Than 10 Mg / L M ) .Cod - Less Than80 Mg / L N ) .Oil & Grease - Less Than 5 Mg / L Sewage Treatment Plant Shall Include The Following Items:A ) .Oil & Grease Chamber B ) . Sewage Equalization Tank C ) .Mbbr Tank ( Moving Bed Bio Reactor ) D ) .Tube Settling Tanke ) .Sludge Holding Tank F ) .Chlorine Contact Tank G ) .Filtration Through Mgf, Acf, Chlorinator & Uv Sterlizerh ) .Air Blowers, Pumps & Equipmenti ) .Filter Pressj ) .Piping, Valves Etc K ) .Electrical Panel & Cablingl ) .All Piping, Valves & Level Indicator / Controller Etc. Within Plant Room. Note: A ) .Contractor Shall Ensure Submission Of Detailed Civil General Arrangement Drawings ( Plan & Section ) , P & I ( Programming & Instrumentation ) Diagram, Schematic Diagram For The Above Mention Component & Additional Component Such As Inserts, Puddle Flanges, Vent Pipes Etc. If So Required For The Complete Working Of The Stp And Got It Approved By The Engineer In Charge. B ) .Only Plateform For Stp Plant Shall Be In The Scope Of The Owners. The Sewerage Treatment Contractor Shall Co-Ordinate, Supervise And Get All The Inserts Installed. All Supply Of Ms / Insert Plates Shall Be In The Scope Of The Sewerage Treatment Contractor.Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) C ) .Supply, Installation, Testing & Commissioning Of 2 Nos Mild Steel 5Mm Frp Coatingperforated Corrugated Bar Screen With Vertical Grating Made By 3 Mm Thick Stainless Steel Plate, Spacing Of Plates 20 Mm C / C Both Sides With Suitable Lifting Arrangement ( Size 750 Mm Wide X 600 Mm High Approx ) D ) .Supply, Installation, Testing And Commissioning Of The Following Tanks And Chambers In Hdpe / Pvc As Per Approved Drawings And Directions Of Engineer Incharge. The Cost Shall Include All The Required Mswalking Platform, Handrail, Staircase, Manhole Cover Etc. All Above Quoted With Minimum 10Mm M.S Tanks With 5Mm Frp Coating Protectiona ) .Mbbr Tank Of Capacity 25000 Litersb ) .Tube Settler Tank Of M Sc ) .Sludge Holding Tank Of Capacity 5000 Litresd ) .Chlorine Contact Tank Of Capacity 10000 Litrese ) .Treated Water Tank Of Capacity 15000 Litres Quoted With Minimum 10Mm M.S Tanks And All Above Item As Per Design Requirments ( No Extra Payment Shall Be Paid ) 90 Supply, Installation, Testing & Commissioning Of Horizontal Type Pumps, Having Cast Iron Body, C.I. Impeller & Shaft Connected To Tefc Motor For 415 Volts, 3 Phase, 50 Cycles A.C. Power Supply Withmechanical / Gland Seal. Protection Complete In All Respects Including Suction And Delivery Headers With Upvc Pipe Of Required Dia, Isolation Valves, Nrv & Pumps Shall Have Following Duty: A ) .Raw Sewage Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 40 Mm Size ) Set Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 2.5 Lps ( Required- 2.5M3 / Hr ) Head - 10-12 Mtr.H.P.-2 Hp Approx. 91 B ) .Submersible Sewage Lifting Pumpset Of Two Pumps ( 1 Working + 1 Standby ) Capacity - 1.5 Lpshead - 10-12 Mtr.H.P.-2 Hp Approx. ( Solid Handling Capacity Upto 40 Mm Size ) 92 Supply, Installation, Testing & Commissioning Of Electromagnetic Type Flow Meter At The Outlet Point Of Raw Sewage Transfer Pump Of 50 Mm Size Suitable For 0 - 15 Klh Flow. 93 Supply, Installation, Testing & Commissioning Of Twin Type Rotary Air Blower With Acoustic Encloser, Driven Through “V” Belt Or Directly Coupled Through Flexible Coupling To A Tefc Motor Of Suitable Hp Suitable For 415 ± 10% Volts, 3 Phase, 50 Cycles A / C Supply. Capable Of Delivering 70 Cum / Hr Of Free Air At 0.5 Kg / Cm2. 94 Supply, Installation, Testing & Commissioning Of Air Piping Shall Comprise Of Pipes Droppers / Laterals With Ms ( Epoxy Coated ) Header Complete With All Fittings Such As Tees, Crosses, Plugs, Sockets, Elbows, Reducers, Supports & Clamps, Puddle Flanges Etc Including Cutting Holes In Wall, Makes Chases In Wall And Making Good The Same. Contractor To Submit Detailed P&I Indicating Their Proposal. 95 Supply, Installation, Testing & Commissioning Of Fine Air Diffusers Capable Of Delivering 10-12 Cum / Hr In Mbbr Tank For Providing Areation. 96 Supply, Installation, Testing & Commissioning Of Coarse Air Diffusers Capable Of Delivering 3-6 Cum / Hr In Equalization Tank And Sludge Holding Tank For Providing Areation. 97 Supply, Installation, Testing And Commissioning Of High Surface Area @ 400 M2 / M3 At Least Ring Type Media To Be Used For Bacterial Growth Installed In Moving Bed Bio Reactor Tanks. 98 Supply, Installation, Testing And Commissioning Of Pvc Tube Deck Settling Media To Be Installed In Tube Settling Tank. The Media To Be Supported On Msep Frame With Baffle Plate & Overflow Launder. 99 Supply, Installation, Testing And Commissioning Of Single Stage Horizontal Centrifugal Self Priming Pump With With C.I Body, Bronze Impeller, Shaft Of Stainless Steel, Shaft Sleeve Of Chrome Steel And Delivery Casing In C.I With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415+ / - 10%Volts, 3Phase50 Cycles A.C. Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Sequence Running Controller, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Includingisolation Valves, Nrv & Vibration Eliminators On Both Suction & Delivery Side Of Pumps .Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information. A ) .Sludge Feed / Transfer Pump ( Pumps To Be Suitable To Handle Solid Handling Capacity Upto 8-10 Mm Size ) B ) .Set Of Two Pumps ( 1 Working + 1 Standby ) C ) . Capacity- 1.5 Lpsd ) .Head - 10.0 Mtr. E ) .H.P.-1.5 Hp Approx. 100 Supply, Installation, Testing And Commissioning Of Horizontal Centrifugal Pumping Set With Cast Iron Body, Bronze Impeller, Shaft Of Ss And C.I. Base & Head With Mechanical Seal, Connected To A Tefc Inductionmotor Suitable For 415 + / - 10%Volts, 3 Phase 50 Cycles A.C Supply With 150Mm Dia Pressure Gauge With Gunmetal Isolation Cock, Vibration Eliminating Pads Under Foundation, Dry Running Protection, 80X40 Mm I Section Base Plate Bolted To Cement Concrete Foundations Complete Including Isolation Valves, Vibration Eliminators On Both Suction & Delivery Side Of Pumps And Nrv On Delivery Side Of Pumps Vendor To Submit Performance Curves And Technical Catalogue Of The Proposed Model For Review And Information.A ) .Filter Feed Pumpsb.Set Of Two Pumps ( 1 Working + 1 Standby ) C ) .Capacity- 3.0 Lps ( Suggested And Quoted For 5000Lph ) D ) .Head - 30.0 Mtr.E ) .H.P.-3.0 Hp Approx. 101 Supply, Installation, Testing & Commissioning Of Vertical Self Supporting Filtration Unit Fabricated From Ms Sheet As Per Is: 2825 ( Minimum Thickness Of Shell 8 Mm And Dished Ends 10 Mm ) Pressure Gauges, Sample Cock, Gi Class C Face Piping, Ci Butterfly Valves And All Accessories, With Initial Charge Of Filter Media Including Anthracite, Painting Inside With Epoxy Paint And Outside With Two Coat Of Red Oxide Primer And Two Or More Coat Of Synthetic Enamel Paint, Testingand Commissioning Complete.A ) .Mulitgrade Pressure Sand Filtercapacity - 5000 Lph Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm. Test Pressure : 4. 5 Kg / Sq Cm 102 B ) .Activated Carbon Filter Filtration Rate -14000Lph / Sqm Filter Dia Approx. - 800 Mm Working Pressure: 3.0 Kg / Sqcm.Test Pressure : 4. 5 Kg / Sq Cm 103 Supply, Installation, Testing & Commissioning Of Metering Pump Type Chemical Doser With 100 Lits. Pvc / Hdpe Solution Tank, Injection Fitting Assembly, Suction And Delivery Hose Upto The Point Of Injection, Capacity 0-6 Lph, Complete In All Respects. 104 Supply, Installation, Testing & Commissioning Of Ultravoilet Dis-Infection Unit. The Unit Shall Have Over 99.9 % Bacterial Reduction From Inlet To Outlet. The Dis-Infection Chamber Shall Be Constructed Of Ss 316L On All Welted Parts. The Uv Lamp Shall Be Of Low Pressure Mercury Vapour Type With Hard Glass Enclosure, The Sockets Shall Be Water Tight & Vibration Resistant. The Lamp Life Shall Be Rated For 6000 Hours. The Unit Shall Be Complete With Temperature Safety Control, Lamp Out Alert Circuit & Uv Radiometer With 4 – 20 Ma Output. The Uv Unit Shall Have With Reactor, Cabinet Housing, Cabinet Cooling, Treatment Chamber, Electrical Panel, Temperature Safety Control, Lampout Alert, Uv Radiometer Along With Uv Monitoring System And Uv Monitoring Readout Panel.The Uv Dosage Should Be > 60, 000 Uw – Sec / Sq.Cm. The Lamps Should Be Selected Based Upon The Flow Requirement Of Respective Unit.Flow Rate : 5 Cum / Hr 105 Supply, Installation, Testing & Commissioning Of All Pipings ( As Described Below ) And Isolation Control Valves Including All Necessary Fittings And Clamps, Supports, Hangers As Required I / C Cutting And Making Good The Walls Wherever Required Complete In All Respects For Making The System Complete.A ) .Gi : Submerged Air Piping ( We Suggest Upvc. Gi Is Never Used For Submerged Piping ) Ms Epoxy: Air Piping & Pumped Effluent Riser ( Non-Submerged ) Upvc : Interconnecting Pipe Line After Delivery Header Of Pump / Filtercontrollers With Low Voltage Relays, Stainless Steel Probes And Pvc Shroud, Control Cabling As Required Length. ( No Of Probes As Required For Function Of Each Controller ) . 106 B ) .Filter Feed Pumps To Cut Off Duty Pump On Low Water Level In The Chlorine Contact Tank And High Water Level In The Treated Water Tank And To Start Pump At Low Water Level In The Treated Water Tank. 107 Supply, Installation, Testing & Commissioning Of Filter Press Of Plate Size 18X 18X 12 Nos. Plate With Screw Feed Pumps Of 5 M3 / Hr @ 40 M Head Capacity ( 1 Working + 1 Standby ) Complete In All Respects. 108 Providing Installing Testing And Commissioning Of Ultra Filteration ( Uf ) System For Further Polishing Treated Effluent And Capable Of Producing 5, 000 Litre / Hour. The System Shall Be Complete With Uf Feed Pumps ( 1W+1S ) , Backwash Pumps ( 1W+1S ) , Cartridge Filters ( Fabricated| ) , Uf Membranes Flushing / Cleaning System Complete Instrumentation For Automation And Monitoring Rotameters Pressure Gauges Interconnecting Pipeword Electrical Cabling And Switchgear, All Complete Electrical Installation For Stp 109 Design, Fabrication, Assembling, Wiring, Supply, Installation, Testing And Commissioning Of Motor Control Centre Fabricated Out Of 14 Gauge Crca Sheet Steel. Cable Gland Plates Shall Be Provided On Top As Well As At The Bottom Of The Panels. Panels Shall Be Treated With All Anticorrosive Process Before Painting As Per Specifications With 2 Coats Of Red Oxide Primer And Final Approved Shade Of Powder Coated Paint. 2 Nos. Earthing Terminals Shall Be Provided For 3 Phase, 4 Wire, 50 Hz Supply System. Lifting Hooks Shall Also Be Provided In Case Of Large Panels. Approval Shall Be Taken For Each Panel Before Fabrication. Quoted Rates Shall Be Inclusive Of Cables ( In Accordance To Specification ) With Earthing From Panel To Each Motor / Equipment.Motor Control Centreincoming: A ) .200 Amps Tpn Mccb With The Following Accessories:B ) .0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.C ) .0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set. D ) .Pharse Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets. Bus Bar:A ) .200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing; A ) .10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For ‘On / Off / Trip’ Status Of Motor B ) .Spare 25 Amps TpnmcbS2 Nos. C ) .Spare 32 Amps TpnmcbS2 Nos. D ) .Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Mcc For All Stp Equipments / Pumps As Described Above.Notes : A ) .All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.B ) .All Motor Starters Shall Be Provided With Automatic Level Controller. C ) .Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors . Motor Control Centre Incoming 200 Amps Tpn Mccb With The Following Accessories:0-500 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch Shall Be Protected By 2 Amps Tp Mcb. 1 Set.0-100 Volts 96 X 96 Mm Square Electronic Voltmeter With Selector Switch And Shall Be 100. / 5 Amps 10 Va Cl: Cts. 1 Set.Phase Indicating Lamps Shall Be Protected By 2 Amp Sp Mcb 3 Sets.Bus Bar 200 Amps Tpn ( 15 Ka ) Copper Bus Bar With Heat Shrinkable Insulation Sleeves.Outgoing10 Nos. Of 25 Amp Capacity Tpn Mcb With 10 Nos. Dol Starters And Out Going Feeders To All The Pumps Etc. ( Including Standbies ) . Each Compartment Shall Contain Auto / Manual Selector Switch Andindicating Lamp With Mcb’S For‘On / Off / Trip’ Status Of Motorspare 25 Amps TpnmcbS2 Nos. Spare 32 Amps TpnmcbS2 Nos. Necessary Cable Alleys, Internal / Cabling, Wiring, Cabling From Mcc To Various Pumps / Equipment And Interlocking, Earthing For All Equipment Shall Also Included Notes : All Mccbs / Mcbs Shall Be Of 15 Ka Breaking Capacity And Suitable For Motor Duty Application.All Motor Starters Shall Be Provided With Automatic Level Controller.Dol Starters Shall Be Used For Motors Below 10Hp And Star-Delta Starters For Other Motors .Provision Shall Be Made For Providing Potential Free Contacts To All Pumps Starters.Mcc For All Stp Equipments / Pumps As Described Above. Sub Total Of Part A 110 Part B ( O & M Cost ) ( For 5 Years ( 60 Months ) From Final Handing Over Of All Works. ) ( Optional ) Trained Operator To Operate The Stp Round The Clockincluding Operator And Regular Visit Of Supervisor. Perannum Including All Charges Like Amc , Monthly Charges Of Water Analysis And All Consumables Etc Included. Sub Total Of Part B ( Rate Only ) 111 Part:C Providing & Laying Upvc Pressure Pipes Of 6 Kg / Sq.Cm Pressure Rating Class 3 ( Is : 4985-2000 ) Including Fittings, Tees, Bends, Clamps, Coupling And Adaptors Supports, And Jointing With Solvent Joint, Testing And Necessary Earth Work In Excavation, Backfilling, Disposal Of Surplus Earth With A Lead Up To 100M Complete, Compaction And Consolidation Including Sand Bedding All Around Upvc Pipe & Fittings And Thrust Blocks At Bends As Per Standard Design.200Od 112 Constructing Rccchamber Of Holding Capacity 10 M3 With Grade Of M25 Including Cost Of Centering , Shuttering & Pcc Below Foundation In 1: 5:10 & 75 Mm Thick And Inside Chamber Of 75Mm Thick As Per Standard Design Including Inside Plastering With Cement Mortar 1:6 ( 1 Cement :6 Coarse Sand ) 12 Mm Thick Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design .Rate To Include Cost Of Reinforcement , Excavation And Filling Of Earth. Earth Work In Excavation By Mechanical Means ( Hydraulic Excavator ) / Manual Means In Foundation Trenches Or Drains ( Not Exceeding 1.5 M In Width Or 10 Sqm On Plan ) , Including Dressing Of Sides And Ramming Of Bottoms, Lift Upto 1.5 M, Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed, Within A Lead Of 50 M. The Contractor Has To Detect Different Unilities Like Sewer Line , Water Supply Line , Electrical Cable , Telephone Cable , Gas Pipe Line Etc. Using Utility Detecting Machine Before Start Of Excavation And Shall Start Excavation Only After Getting Permission Of Engineer In Charge.All Kinds Of Soil.Depth Upto 1.5M From Existing Ground Level 113 B ) Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Up To 50 M And Lift Upto 1.5 M. 114 Providing & Laying Cement Concrete - All Works Upto Plinth Level : C ) 1:4:8 ( 1 Cement : 4 Coarse Sand ( Zone-Iii ) : 8 Graded Stone Aggregate 40 Mm Nominal Size ) 115 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-In-Charge. ( Note :- Cement Content Considered In This Item Is @ 330 Kg / Cum. Excess / Less Cement Used As Per Design Mix Is Payable / Recoverable Separately ) . A ) Uptoplinth 116 Steel Reinforcement For R.C.C. Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete Upto Plinth Level.B ) Thermo-Mechanically Treated Bars Of Grade Fe-500D Or More 117 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For : C ) Foundations, Footings, Bases Of Columns, Etc. For Mass Concrete 118 D ) Suspended Floors, Roofs, Landings, Balconies And Access Platform 119 Brick Work With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 10 In Foundation And Plinth In: A ) Cement Mortar 1:6 ( 1 Cement : 6 Coarse Sand ) For 230Mm Thick Brick Work 120 B ) 12 Mm Cement Plaster Of Mix :1:4 ( 1 Cement: 4 Fine Sand ) 121 C ) 15 Mm Cement Plaster On Rough Side Of Single Orbrick Wall Of Mix:1:4 ( 1 Cement: 4 Fine Sand ) 122 D ) 6 Mm Cement Plaster Of Mix :1:3 ( 1 Cement : 3 Fine Sand ) 123 Designing, Preparation Of Shop Drawings, Supplying, Erection, Testing, Commissioning Of All Mechanical, Electrical And Other Components Including Getting Approval Of Successful Test Results From Approved / Authorized Agency From Pollution & Environmental Authorities, Operating & Maintaining Upto Successful Commissioning, For 5 M3 / Day Capacity Sewage Treatment Plant Sewage Treatment Plant Near Workshop Area ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) Suprime / Sintex Maketotal C / F To Summary 124 R.O Water Treatmentplant: Supply, Installation, Testing And Commissioning Of R.O. Plant Capacity Of 750 Lph ( Complete System To Be Compact Type, Skid-Mounted / Cabinet Enclosed, As Per Detailed Shop Drawings To Be Approved ) For The Following Parameters And Consisting Of ( But Not Limited To ) The Following Main Components:- ( I ) Inlet Quantity : As Per Detailing ( Ii ) Output Quantity : 750 Lph ( Iii ) Inlet Tds : 600 Ppm ( Iv ) Outlet Tds : 75 Ppm ( V ) Inlet Hardness : 350 Ppm ) ( Vi ) Outlet Hardness : 50 Ppm ) Raw Water Pumps Of Horizontal, Centrifugal Type Suitable For A Flow Rate Of 1500 Lph At 25M Head. The Pump Construction Shall Be Of Ss-304 & Impeller Shall Be Also Ss-304. The Motor Shall Be Tefc Suitable For A Supply Of 415V / 3-Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundations, Bolts, Pressure Gauge At Inlet And Outlet Of Each Pump. -- 2 Nos. ( 1W+1S ) Special Antiscalant Dosing System Consisting Of One Hdpe Tank Of 100 Litre Capacity With A Positive Displacement Diaphragm Dosing Pump Having Variable Flowrate Of 0-6 Lph. The Motor Shall Be Suitable For Operation At 240V / Single Phase / 50Hz Supply. The Pump Shall Be Supplied Complete With Necessary Polypropylene Piping, Valves, Strainers & Injection Fittings. -- 1 Set Micron Cartridge Filter Suitable For A Flowrate Of 1500 Lph To Achieve Particle Filtration Of Less Than 5 Microns. The Unit Shall Be Supplied Complete With Inlet And Outlet Branches Removal Cap For Replacement Of Element, Inlet And Outlet Pressure Indicators. ( One For The Pressure Treatment & Other For Cip System ) Moc: Polypropylene -- 2 Sets R.O High Pressure Feed Pumps Of Vertical, Multistage Centrifugal Type Suitable For A Flowrate Of2000 Lph At 14 Kg / Sq.Cm. The Pump Construction Shall Be Of Ss-316-L & Impeller Shall Be Also Ss-316-L. The Motor Shall Be Of Tefc Suitable For A Supply Of 415V / 3 Phase / 50 Hz Supply. The Pump Shall Be Supplied Complete With Base Channel Coupling Foundation, Bolt, Pressure Gauge At Inlet And Outlet Of Each Pump.- 2 Nos.R.O. Modules Made Out Of Spiral Wound Thin Film Composite Suitable To Withstand Pressure Of 20Kg / Sq.Cm. Suitable Bspt / Npt Connections Shall Be Used For Connecting Feed & Reject Ends. The Modules Shall Be Supplied Complete With All Necessary Instrumentation, Valves For Sampling, Drain, Reject & Permeate, Epoxy-Coated Structural Steel Bases And Supports, As Per Following System Capacity Requirements: ( I ) Total Net Treated Water Output Of System = 750 Lph ( Ii ) System Recovery= 50 - 60 % ( Iii ) Filtration Area Per Membrane = 85 Sq.Ft. ( Iv ) Number Of Membranes = The Total Number Of Membranes Required Shall Beas Per Requirements, Supported By Calculations From The Vendor. Centralised Plc Control Panelalong With Touch-Screen Digitial Display Board Along With All Digital Sensors For Tds & Flow, Made Out Of Crca Sheet Min. 2Mm Thick Having Main Contactors For All Pumps ( Listed Above ) Including Spp, 3 Phase Thermal Overload Relay. The Control Panel For Monitoring And Control Of P.O. System Shall Include All Required Signal Lamps, Hrc Fuses, Annunciation Box With Hooter. All Control And Power Cabling Along With Double Earthing Between The Panel Shall Be Included In The Scope Of Supply Of The Contractor. An Emergency Stop Push Button Shall Be Provided In The Panel. The Mcc Panel Shall Have The Following Interlocks:- I ) High Pressure Pump Unit Trip In Case Of Low Suction Pressure. Ii ) High Pressure Pump Unit Trip In Case Of High Discharge Pressure.Iii ) Special Anti-Scalant Dosing Pump Trips In Case High Pressure Pump Trips And Vice Versa.Iv ) High Pressure Pump Trip In Case Of High Conductivity In Permeate.V ) Shc Dosing Pump Trips Incase High Pressure Pump Trips And Vice Versa. Vi ) Orp With Dump Valve.-- 1 Seti ) First Fill Of All Chemicals And Lubricants To Commission And Operate The Plants. --1Lotj ) All Interconnecting Piping Work With Valves:- I ) Low Pressure Side Till R.O. Feed Water Pump. Piping Shall Be Of Extra Strong Pvc And All Valves Shall Be Of Extra Strong Pvc And All Valves Shall Be Pvc Ball Valves. -- 1 Lotii ) High Pressure Side Piping From The R.O. High Pressure Pumps To The Reject Stream Control Valves Shall Be Of Ss - 304 Using All Ss Fittings Ball Valves Of Suitable Pressure Rating Shall Be Used Till 25 Mm Size, Above 25 Mm, Flanged Globe / Wafer Butterfly Valves In Ss Construction Shall Be Used. Rejects Pressure Control Valves Shall Be Globe Valve And Feed Flow Control Valve Shall Be Of Ss-304. -- Lotiii ) Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants. ( All For Above From A To J Complete ) 125 R.O Water Storage Complete 316 Stainless Steel Treated Water Storage Tank ( Double Wall ) Of Capacity 2000 Litres Including All Inlet / Outlet Connections, Accessories, Valves, Double Seal Manhole Covers, Insulation Etc.The Stainless Steel Tank Must Be Ozone Resistant And To Be Used As Ozone Contact Tank. Fabrication To Be Done As Per Approved Shop Drawing. ( Make :Nector ) 126 Providing And Placing On Terrace ( At All Floor Levels ) Polyethylene Water Storage Tank, Is : 12701 Marked, With Cover And Suitable Locking Arrangement And Making Necessary Holes For Inlet, Outlet And Overflowpipes But Without Fittings And The Base Support For Tank.. 127 Activated Carbon Filter ( Automatic Type For Online Installation Before The Micron Filters ) Suitable For A Flow Rate Of 1500 Lph. The Material Of Construction Shall Be Composite Frp. The Unit Shall Be Supplied Complete With Multi-Port Valves, Inlet And Outlet Branches Removal Caps Of Replacement Of Elements Inlet And Outlet Pressure Indicators. -- 1 Set 128 Hydropneumatic System For R.O Supply Providing Fixing And Commissioning Suitable Complete Composite Hydropneumatic System Consisting Ofhorizontal / Vertical Multistage Centrifugal Pump Having Stainless Steel Impellers, Stainlesssteel Shaft, Stainless Housing And Single Mechanical Seal And Pressurised Tankof Required Specifications And Of Non-Toxic Rubber Diaphragm, Complete With All Accessories Including Pressure Switch, Pressure Gauge And Electrical Panel With All Necessary Protection And Operational Devices I.E Alternate Pumping Operation And Shut Off During Dry Running Conditions Etc., And Inclusive Of Ss 316 Suction And Delivery Manifold Of Required Size With Non-Return Valve And Ball Valveand Withsuitableelectrical Motor To Be Operated On 210 / 220 Or 400 / 440 Volt 50 Cycle Suitable For Following Duty And With Total No. Of Pumps - 2 Nos. ( 1 Working+ 1 Standby ) Complete With The Approval Of Engineer-In-Charge.- Before Procurement Of Material Contractor Should Be Get Technical Approval From Consultants.A ) Discharge:150 Lpmb ) Head:45 M C ) App. Capacity Of Thevessel ( Frp ) : As Requiredtotal C / O To Summary 129 Hot Waterboilers And Other Related Accessories Electrical Hot Water Generators System With Solar Back Up.Hot Water Mixing Storage Tank ( 2 Sets For Club And Benquet Hall ) Supply, Installation, Testing And Commissioningof Solarwater Heating System Capable Of Generating 7500Lpd Of Hot Water Per Day At 60 Oc Along Withinsulated Horizontalhot Watermixing Tank Capacityand Design Code I.S: 2825 Fabricatedof 6 Mm Thick S.S. 304Plateand 10 Mmthickdishedend And Nozzles Complete With Inlet, Cold Waterinlet / Outlet Chain Connection Withflanges, Manhole With Bolted Cover With 72 Kw Electrical Back Up Along With Control Panels . Tankshall Beinsulated With 50 Mm Thickresin Bondedfibre Glass ( Density 24 Kg / Cum ) And Covered With500gpolythene Sheetand 24 Gauge Aluminumsheet Cladding Giving Proper Overlaps And Sealing The Joints With Suitable Adhesive Compound, Including The Following Additional Accessories / Specifications:Working Pressure : 7.5 Kg / Cm²i ) Safety Valveii ) Dial Type Thermometer Iii ) Thermowell For Thermostat Elements Cold Water Inlet Valve 80 Mm Dia Check Valve In Cold Water Inlet 80 Mm Dia.Hot Water Inlet / Outletsecondary Side 50 Mm Dia Valve Plate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Diaplate Type Heat Exchanger Compleate With Pumps Required Specification.Hot Water Outlet Connection Valve To System 100Mm Dia Hot Water Return Inlet 65 Mm Dia Drain Valve 50 Mm Diaair Release Valve 25Mm Diahot Water Return Nrv 65 Mm Dia Solar Pre Heating Working Inlet 80 Mm Dia Butterfly Valvesolar Pre Heating Working Inlet 80 Mm Dia Nrv Electrical Control Panel As Per Approved Apecification Temp. Controller 130 Hot Water Returnpumps For Domestic Waterprovidingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Dutynos : 2 ( 1 W +1 S ) Capacity: App.100 Lpm Head :15 M 131 Solar Hot Water Re-Curculation Pumps : Providingand Fixing Horizontal Multistage Centrifugal Pumping Set With Stainless Steel Ss-304 Stage Casing And Ss-304 Impellers With Stainless Steel Ss-304 Shaft As Per Iec Standards Andss - 304 Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitable For 400 / 440 V Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolation Cocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts & Bolts And Necessary Rcc Foundations As Per Requirement As Per Instructions And Pump Shall Follow Following Duty Nos : 2 ( 1 W +1 S ) Capacity: App100 Lpm Head :55 M 132 Electrical Panel Providing Motor Control Centres Fabricated From 16 Gauges M.S. Sheet With Powder Coated Finish. The Control Panels Should Be Comparable With H.P. Of The Motor As Specified.For Hot Water , Steam Genration Systemshot Water Recuculation Pumps, Hot Water Supply Pumps Condensate Pumps Etc.A ) One Incoming Main Isolation Mccb Of Required Rating.B ) Fully Taped Aluminum Bus Bar Ofrequiredcapacity In A Separate Bus Bar Chamber.C ) Isolation Switch Units With Mccbof Required Rating, For Each Unit.D ) Fully Automatic Dol Starter With Pushbutton And On / Off Indicating Lights For Each Unit, For Following Requirements:I ) Hot Water Boilers 2 Nos. Of Required 74 Kw Eachii ) Hot Water Re-Circulation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hp Iii ) Solar Hot Water Recirculation Pumps 2 Nos. ( 1 Working+ 1 Stand By ) Of Required Hpiv ) One No. Spare Feeder Required 5 Hprotary Switches For Auto / Manual On / Off Operations For Each Unit.Rotary Duty Selector Switches.Panel Type Voltmeter 150Mm With Rotary Selector Switch For Reading Voltage Between Phases.Neon Phases Indicating Lights On The Incoming Mains. Single Phasepreventorfor Each Motor. Ct Operated Relayall Internal Wiring Colour Coded From Incoming Mains To Various Switchgear, Starter, Meter, Indicating Lamp And Bus Bar. All The Cable Entry To The Panel Shall Be From The Top. ( All For Above From Item ( A ) To ( L ) Complete Set ) . ( The Shop Drawing To Be Preparedand Approved Before Fabrication ) Total C / O To Summary 133 Swimming Pool Filteration System Recirculation Pumps Main Pool + Jacuzziarea : 550 M2 X 1.2 M Balancing Tank : 60 M3total Pool Volume : 660 M3 + 60 M3 = 720 M3filtration Flow Rate : 180M3 / Hr Filtration Plant With Pumpsupply, Instalation, Testing & Commissioning Of Bobbin Wound Side Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Fitted With Collector Arms And Diffuser Made From Unplasticised Pvc And Polypropylenewith Lid In Polyester Resin And Fibre Glass, Manual Air Purgeand 4 Pvc Flanged Connection For Inlet And Outlet, Pressure Gauge, Water Drain / Empty Drain For Filter Etc.Complete In All Respects. Including Corse & Fine Silica Sand Media For Filterapx. 7200Kgcapacity 60000 Ltrs / Hrdesign @30000 Ltrs / Sqm / Hr.Diameter1600 Mm Working Pressure4.0 Kg / Cm² 134 Valve Battery Valve Battery Manifold Made In Pvc With Flanges For Connecting To Filters Consists Of Set Of 5 - Buttterfly Valves For Carrying Out Filtration, Back-Washing, Rinsing And Shut Down Of The Filters. Size : 4 Inchsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) 135 Supply, Instalation, Testing & Commissioning Of Self Primingpumps With Ci Body, In Built Ci Strainer Basket, Impeller In Ci / Bronge, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic - Sic / Carbon - Ceramic, Motor Housing In Aluminium, Withmotor -2850Rpm, F Class Insulation, Protection Ip-55. ( 3W+1S ) Capacity60000 Ltrs / Hrhead 16 Mtrhp 7.5, Three Phase 136 Swimming Pool U.V. Sterlizersupply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 60000 Ltr / Hrworking Pressure = 4.0 Kg / Sqm Uv Lamp Wattage = 400 W 137 Dosing Pumpsupply, Instalation, Testing & Commissioning Of Chemical Dosing Pumpfor Chlorination With 200 Ltrs. Sintex Tank And Accessories Capacity0-20 Litres / Hr.Head35 M 138 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 400X400 Mm 139 Inlet Nozzlesupply, Instalation, Testing & Commissioning Of Flow Adjastable Abs Inlet Nozzles Uv Treated With S.S. Screws To Fit In The 2 Pvc Pipes 140 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 141 Supply, Instalation, Testing & Commissioning Of Stainless Laddersteel 316 Ladders, Width: 500Mm Wide, Handrails Dia 43Mm Stainless Steel, Non-Slip Stepsprovided With Anchoring Socket.A ) 3 Step Standard Ladder With Anti-Skid Steps 142 B ) 4 Step Standard Ladder With Anti-Skid Steps 143 Underwater Led Lights Supply, Instalation, Testing & Commissioning Of 12Volt 54 W Under Water Stainless Steel 316L Led Light Fixture ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord. 144 Power Supply Supply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 145 Deck Box Supply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 146 Cleaning Accessories A ) Extensivetelescopic Handle, ( 2.4 - 4.8 ) Metres Long &1.1Mm Thick For Cleaning Attachment In Anodized Almunium. 147 B ) Transparent Blue Polyethylene Hose 40Mm ( 1-1 / 2 ) Dia 30 M Length. 148 C ) Surface Net Skimmer Made In Polypropylne 149 D ) Deep Bag Net Skimmer Made In Polypropylne 150 E ) Curved Polybristle Wall Brush 450 Mm 151 F ) Test Kit For Ph And Chlorine. 152 G ) Hi-Grade Stainless Steel Algae Brush - 10 153 H ) Vacuum Head With Ss-Body, 1 1 / 2 Connection Size 900 Mm Long 154 I ) Deluxe Large Vacuum Head With 4 Wheels, Alu-Body, Plastic Handle, 1 1 / 2 Connection Size 445X130 Mm 155 J ) Polybristle Wall Brush 10 ( 26Cm ) 156 K ) Chemical Tcca 90 ( 50 Kg. ) & Alum ( 30 Kg. ) 157 L ) Nylon Rope 158 Upvc Pipesproviding And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 159 B ) 50 Mm Dia 160 C ) 63 Mm Dia 161 D ) 75 Mm Dia 162 E ) 90 Mm Dia 163 F ) 110 Mm Dia 164 G ) 160 Mm Dia 165 H ) 200 Mm Dia 166 I ) 250 Mm Dia 167 Ball Valveproviding And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia 168 40Mm Dia ( Rate Only ) 169 50Mm Dia ( Rate Only ) 170 63Mm Dia 171 75Mm Dia ( Rate Only ) 172 90Mm Dia ( Rate Only ) 173 Butterfly Valve Providing And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required. A ) 90 Mm Dia 174 B ) 110 Mm Dia 175 C ) 160 Mm Dia 176 D ) 200 Mm Dia 177 E ) 250 Mm Dia 178 Non Return Valveproviding And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 50Mm Dia 179 B ) 63Mm Dia 180 C ) 75Mm Dia 181 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes.A ) 75Mm Dia 182 B ) 90 Mm Dia 183 C ) 110 Mm Dia 184 D ) 160 Mm Dia 185 E ) 200 Mm Dia 186 F ) 250 Mm Dia 187 Puddles Sleevesupply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia 188 C ) 50 Mm Dia 189 D ) 63 Mm Dia 190 E ) 75 Mm Dia 191 F ) 90 Mm Dia 192 G ) 110 Mm Dia 193 H ) 160 Mm Dia 194 I ) 200 Mm Dia 195 J ) 250 Mm Dia 196 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 300Mm Dia Pump Suction Header With 2 Nos 200Mm Dia Flange Connection For Balancing Tank To Pump Suction Header, 1 No. 90 Mm Dia Flange Connection For Vacuum Pipe & 1 No. 200 Mm Dia Flange Connection For Pool Drain Pipe & 4No. 200Mm Dia & 2 No. 160Mm Diaflange Connection For Pump Suction. 197 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 198 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 199 C ) 4 X 6 Sq.Mm ( Rate Only ) 200 D ) 4 X 4 Sq.Mm ( Rate Only ) 201 E ) 4 X 2.5 Sq.Mm 202 F ) 4 X 1.5 Sq.Mm ( Rate Only ) 203 G ) 3 X 6 Sq.Mm ( Rate Only ) 204 H ) 3 X 4 Sq.Mm 205 I ) 3 X 2.5 Sq.Mm ( Rate Only ) 206 J ) 3 X 1.5 Sq.Mm ( Rate Only ) 207 K ) 2 X 6 Sq.Mm 208 L ) 2 X 4 Sq.Mm ( Rate Only ) 209 M ) 2 X 2.5 Sq.Mm 210 N ) 2 X 1.5 Sq.Mm 211 Providing And Fixing 6 Swg Dia G.I. Wire On Surface Or In 6 Gauge Gi Wire Recess For Loop Earthing As Required. 212 Supplying And Installing Following Size Of Perforated Painted With Powder Coating M.S. Cable Trays With Perforation Not More Than 17.5%, In Convenient Sections, Joined With Connectors, Suspended From The Ceiling With M.S. Suspenders Including Bolts & Nuts, Painting Suspenders Etc As Required. A ) 300 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 213 B ) 150 Mm Width X 50 Mm Depth X 1.6 Mm Thickness 214 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 215 Electrical Control Panel Supply, Installation, Testing And Commissioning Of Following Swimming Pool Panel 415 V, 1 / 3 Phase And 50 Hz Power Distribution System. Thepanel Shall Be Free Standing Floor Mounting Sheet Metal Enclosed Dust And Vermin Proof Confirming To Ip-54, Compartmentalized Design Fabricated Out Of 16 Swg Sheet Steel, Painting Earthing Numbering, Danger Plate As Per Specifications And Drawings. Flush Front With Aluminium Busbars, Seperate Earth Bus Bars To Be Provided Throughout The Length Of The Panel The Incoming And Outgoing Feeder Breakers, Fuses, Indicating Lamps Etc Shall Be Accomadated In A Modular Multilier Arrangement. The Panel Shall Be Powder Coated Through 9 Tank Process. Adequate Size Cable Alley Shall Be Provided Forcable Termination.The Outgoing Feeders Inside Shall Be Connected Through Bus Bars / Flexible Cable Links. Incoming: One ( 1 ) No. 200A Tp 25 Ka Mccb With Thermomagnetic Digital Flush Mounted 0-200A Ammeter With 3 Way And Off Selection Switch With 3 Nos. 200 / 5 Amp Ct. 1 Set ( 3 Nos. ) Of Phase Indication Lamps 200A 25 Ka Tpn Aluminium Bus Bar. It Shall Be Insulated With Heat Shrinkable Sleeves And Shall Be Color Coded. Outgoing: Recirculation Pumpsix ( 6 ) Nos. Star Delta Starter Complete With Separate Single Phasing Protection Feature. On / Off Indicating Lamps, Relay, Contractors, Start / Stop Push Button, Auto / Manual Selector Switch, Sufficient Nos Of Potential Free Spare Contacts, Etc For Suitable Hp3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Chemical Dosing3 Nos. Toggle Switch For Doser3 Nos. 6Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Uv 3 Nos. Toggle Switch For Uv 1 Nos.16Amp Dp Mcb Of Suitable Rating With Correct Thermal Range Suitable For Underwater Lights 1 Nos. Toggle Switch For Led Pool Lightstotal C / O To Summary 216 Entry Water Bodypressure Sand Filtersupply, Instalation, Testing & Commissioning Of Bobbin Wound Top Mount Sand Filter Manufactured With Fiber Glass And Polyester Resin, Uv Resistance Surface, Non Corrosive Material, Complete With 6-Way 2 Multiport Valve With Filter Connection / Inter-Connecting Piping, Pressure Gauge, Water Drain / Empty Drain For Filter.Including Corse & Fine Sand Media For Filter As Per Approved Calculation Capacity15000 Ltrs / Hr Design @35000Ltrs / Sqm / Hr. Diameter750 Mm 217 Filter Re-Circulation Pumpsupply, Instalation, Testing & Commissioning Of Self Primingpumps With Plastic Body, In Built Strainer Basket, Impeller In Ppo, Motor Shaft In Stainless Steel Aisi-420, Mechanical Seal In Sic / Graphite And Steatite, Motor Housing In Aluminium, Withmotor -2800Rpm, F Class Insulation, Protection Ip-55. ( 1W+1S ) Capacity15000 Ltrs / Hr Head 12 Mtrhp 2.0, Three Phase 218 Fountain Re-Circulation Pump Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp7.5, Three Phase 219 Single Stage High Speed Horizontal Centrifugal Monobloc With Volute Type Delivery Casing Pool Recirculation Submersible Pump, Delivery Casing & Motor Body In Ci, Motorshafts In Carbon Steel, Impeller In Ci Withmotor Hp2.0, Single Phase 220 Swimming Pool U.V. Sterlizer Supply, Instalation, Testing & Commissioning Of U.V. Sterlizer With S.S. Housing Outside, U.V. Lamp, Glass Tube And All Other Accessories With Cleaning Arrangement, Supports, Inlet Outlet Connection With Bypass Arrangement Including S.S. Cabinet With Glass Door Of Suitable Size To House The U.V. Sterlizer Complete With Required Accessories. Flow Rate = 20000 Ltr / Hrworking Pressure = 2.5 Kg / Sqmuv Lamp Wattage = 40 W 221 Chlorine Tablet Feedersupply, Instalation, Testing & Commissioning Of Chlorine Tablet Feeder With Accessories Capacity = 4.5 Kg 222 Stainless Steel Drain Supply, Instalation, Testing & Commissioning Ofstainless Steel Drain Grating Plate Made Out Of 316 Quality S S Plates With Suitable Supporting Frame And Of Following Sizes And Having Holes Of Required Size For Drainout Chamber.Size 200X200 Mm 223 Fountain Nozzlesupply, Instalation, Testing & Commissioning Of Brass Crome Plated Gyserjet Nozzle With 1 Connection With Required Accessories. 224 Suction Inlets ( Vacuum Points ) Supply, Instalation, Testing & Commissioning Of Abs White Plastic Suction Port / Vacuum Nozzle With 2 Inch Solvent Cement Connection 225 Supply Of12volt 12W Under Water Stainless Steel 316 Ring Underwater Led Lightstype Led Warm White Light ( Ip 68 ) Including All Required Assessories & Making Connection As Required. With 2 Mtr Power Cord.For Fountain Nozzle 226 Power Supplysupply, Instalation, Testing & Commissioning Oftransformer For Led Lights 12V Dc, 30 Amp 227 Supply, Instalation, Testing & Commissioning Ofrgb Programmer For Led Lights. 228 Deck Boxsupply, Instalation, Testing & Commissioning Of Abs White Plastic Deck. 229 Upvc Pipes Providing And Fixing Upvc Pressure Pipes ( 10Kg / Cm2 ) With Plain Socket Suitable For Solvent Cement Jointing Conforming To Is:4985 / 2000 & Fittings Conforming To Is 7834 / 87.Cut To Required Lengths Including All Necessary Fittings And Specials Such As Bends, Tees, Unions, Reducers, Flanges And Plugs Etc. The Pipes & Fittings Shall Be Tested To A Pressure Of 10 Kg / Sq.Cm.A ) 32 Mm Dia 230 50 Mm Dia 231 63 Mm Dia 232 75 Mm Dia 233 90 Mm Dia 234 110 Mm Dia 235 160 Mm Dia ( Rate Only ) 236 200 Mm Dia ( Rate Only ) 237 Ball Valve Providing And Fixing Pvc Lever Operated Ball Valve Of Full Flow With Setting And Gland Of Superior Quality Having Minimum Ball Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required.A ) 32Mm Dia ( Rate Only ) 238 40Mm Dia ( Rate Only ) 239 50Mm Dia 240 63Mm Dia 241 75Mm Dia 242 90Mm Dia ( Rate Only ) 243 Butterfly Valveproviding And Fixing Upvc Butterfly Valves. Tested To A Pressure Not Less Than10 Kg / Sq.Cm. Including Rubber Gasket, Flanges, Nuts, Bolts, Washers Complete As Required.A ) 90 Mm Dia ( Rate Only ) 244 110Mm Dia 245 160 Mm Dia ( Rate Only ) 246 200 Mm Dia ( Rate Only ) 247 Non Return Valve Providing And Fixing Pvc Ball Type Or Spring Loaded Non Return Valve With Setting And Gland Of Superior Quality Having Minimum Working Pressure Of 10 Kg / Cm2 With Union, Flanges Where As Required. 50Mm Dia ( Rate Only ) 248 63Mm Dia 249 75Mm Dia 250 Providing And Fixing Of Upvc Wafer Check Valve Non-Return Valves ( Pn 10 ) Complete With Matching Flanges, Rubber Insertion, Nuts, Bolts And Washer Etc. Of Following Sizes. A ) 75Mm Dia ( Rate Only ) 251 90 Mm Dia 252 110 Mm Dia 253 Puddles Sleeve Supply & Fixing Of Following Sizes Of Heavy Duty Pvc Puddle Flanges ( Upvc Pipe ( 10 Kg / Cm2 ) Fixed With Flanges, Length 400 To 600 Mm Length ) On The Wall Of Plantroom, Balancing Tank And The Water Body Walls & Slab ( As Required ) . To Be Laid In Between The Steel Reinforcement Before Rcc. Does Not Include Any Civil Work. A ) 32 Mm Dia ( Rate Only ) 254 50Mm Dia ( Rate Only ) 255 Supply, Laying, Testing And Commissioning Of Ss 304 Grade 200Mm Dia Pump Delivery Header With 1 Nos 200Mm Dia Flange Connection For Filter Inlet Header, 1 No. 160 Mm Dia Flange Connection For Drain Pipe & 4 No. 160Mm Dia Flange Connection For Pump Delivery. 256 Supply, Laying, Testing And Commissioning Of Following Size Pvc Insulated Sheathed Copperconductor 1100 V Grade Unarmoured Cable With Required Size Of Sleeves Complete As Required. A ) 4 X 16 Sq.Mm 257 4 X 2.5 Sq.Mm 258 3 X 4 Sq.Mm 259 2 X 6 Sq.Mm 260 2 X 4 Sq.Mm ( Rate Only ) 261 2 X 1.5 Sq.Mm 262 Providing & Fixing M.S. Structural Work Fabricated From Standard Section E.G. M.S Rounds, Angles, Channels, Plates Including Cutting To Size, Drilling, Welding Fixing And Welding To Insert Plates In Rcc Structural Members As Directed By Engineer-In-Charge Including Cutting And Making Good The Walls, Ceilings And Floors ( For Pipe Supports, Clamps Etc. ) 263 Electrical Control Panelsupply, Installation, Testing And Commissioning Of 415 V, 1 / 3 Phase And 50 Hz Motor. The Switchboard Cubical Indoor Type Made Of 16 Swg Crca Sheet Painted With Powder Coated Paint Of Siemens Grey Shade. The Cubical Is Wall Mounted With Dust & Vermin Proof Construction With Inter Connection. It Comprise With The Following:A ) One Incoming Mains Of 63 Amps. Mccb – Tp, Schneider B ) One No. 0 – 600 V Digital Voltmeter, Mecon Make 96 Sq.Mm With Voltage Selector Switch. Make. C ) Three Phase Led Type Indicating Lights For Incoming Mains. D ) One No. Ct Operated 0 – 60 / 5 A Digital Ammeter, Mecon E ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light F ) Two No. Star Delta Starter Schneider Make With On / Off Push Button And On / Off Indication Light G ) Four No. Auto / Manual Selector Switches, Salzer Make H ) One No. Mcb Dp 6 Amps. For U / V System, Schneider Make. I ) One No. Toggle Switch For U / V System, Hsd Make. J ) One No. Mcb Sp 6 Amps. For Smps Dc Power Supply For Led Light, Schneider Make. K ) One No. Toggle Switch For Led Pool Lights, Hsd Make.Total C / O To Summary 264 Pond Aerationsupply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 1-3 Hp The Aerator Shall Be A Floating 265 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 5-7.5 Hp The Aerator Shall Be A Floating 266 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 267 Supply, Instalation, Testing & Commissioning Of Surface Aerating Fountain With Pump, Float, Spray / Fountain Nozzle, Conrtol, Lights Ss Frame And Cable, Pump Capacity 10 Hp The Aerator Shall Be A Floating 268 Miscellaneous Item ( Hanging Wire Etc ) Total C / O To Summary 269 Golf Course Water Bodies / Ponds Stpwater Supply:Making Connection Of G.I. Distribution Branch With G.I. Main Of Following Sizes By Providing And Fixing Tee, Including Cutting And Threading The Pipe Etc. Complete : A ) 25 To 40 Mm Nominal Bore 270 B ) 50 To 80 Mm Nominal Bore 271 Fixing Water Meter And Stop Cock In G.I. Pipe Line Including Cutting And Threading The Pipe And Making Long Screws Etc. Complete ( Cost Of Water Meter And Stop Cock To Be Paid Separately ) . 272 Brass Fittings Providing And Fixing Gun Metal Gate Valve With C.I. Wheel Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore 273 B ) 20 Mm Nominal Bore 274 C ) 32 Mm Nominal Bore. 275 D ) 40 Mm Nominal Bore 276 E ) 50 Mm Nominal Bore 277 F ) 65 Mm Nominal Bore 278 G ) 80 Mm Nominal Bore 279 Providing And Fixing Ball Valve ( Brass ) Of Approved Quality, High Or Low Pressure, With Plastic Floats Complete : A ) 15 Mm Nominal Bore 280 B ) 20 Mm Nominal Bore 281 C ) 25 Mm Nominal Bore 282 Providing And Fixing Gun Metal Non- Return Valve Of Approved Quality ( Screwed End ) :A ) 25 Mm Nominal Bore Horizontal 283 Vertical 284 B ) 32 Mm Nominal Borehorizontal 285 Vertical 286 C ) 40 Mm Nominal Bore Horizontal 287 Vertical 288 D ) 50 Mm Nominal Bore Horizontal 289 Vertical 290 E ) 65 Mm Nominal Bore Horizontal 291 Vertical 292 F ) 80 Mm Nominal Borehorizontal 293 Vertical 294 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 295 Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :Providing And Fixing Brass Ferrule With C.I. Mouth Cover Including Boring And Tapping The Main :15 Mm Nominal Bore 296 25 Mm Nominal Bore 297 C.I. / Ductile Iron Pipes & Specialsproviding And Laying S&S C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc. ( Heavy Class ) : A ) Up To 300 Mm Dia 298 B ) Over 300 Mm Dia 299 Providing And Laying Flanged C.I. Standard Specials Such As Tees, Bends, Collars, Tapers, Caps Etc., Suitable For Flanged Jointing As Per Is : 1538 :A ) Up To 300 Mm Dia 300 B ) Over 300 Mm Dia 301 Providing And Laying S&S Centrifugally Cast ( Spun ) Iron Pipes ( Class La ) Conforming To Is - 1536 :A ) 100 Mm Dia Pipe 302 B ) 125 Mm Dia Pipe 303 C ) 150 Mm Dia Pipe 304 D ) 200 Mm Dia Pipe 305 E ) 250 Mm Dia Pipe 306 Providing Lead Caulked Joints To Spun Iron Or C.I. Pipes And Specials, Including Testing Of Joints But Excluding The Cost Of Pig Lead : A ) 100 Mm Diameter Pipe 307 B ) 125 Mm Diameter Pipe 308 C ) 150 Mm Diameter Pipe 309 D ) 200 Mm Diameter Pipe 310 E ) 250 Mm Diameter Pipe 311 Providing Flanged Joints To Double Flanged C.I. / D.I. Pipes And Specials, Including Testing Of Joints : A ) 100 Mm Diameter Pipe 312 B ) 125 Mm Diameter Pipe 313 C ) 150 Mm Diameter Pipe 314 D ) 200 Mm Diameter Pipe 315 E ) 250 Mm Diameter Pipe 316 C.I. Sluice Valves / Fire Hydrants & Fixturesproviding And Fixing C.I. Sluice Valves ( With Cap ) Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :A ) 100 Mm Diameterclass I 317 Class Ii 318 B ) 150 Mm Diameter Class I 319 Class Ii 320 200 Mm Diameter Class I 321 Class Ii 322 250 Mm Diameterclass I 323 Class Ii 324 300 Mm Diameter Class I 325 Class Ii 326 Constructing Masonry Chamber 60X60x75 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 327 Constructing Masonry Chamber 90X90x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 328 Constructing Masonry Chamber 120X120x100 Cm Inside, In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Sluice Valve, With C.I. Surface Box 100 Mm Top Diameter, 160 Mm Bottom Diameter And 180 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand : 10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 329 Constructing Masonry Chamber 60X60x75 Cm, Inside In Brick Work In Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) For Fire Hydrants, With C.I. Surface Box 350X350 Mm Top And 165 Mm Deep ( Inside ) With Chained Lid And Rcc Top Slab 1:2:4 Mix ( 1 Cement : 2 Coarse Sand : 4 Graded Stone Aggregate 20 Mm Nominal Size ) , I / C Necessary Excavation, Foundation Concrete 1:5:10 ( 1 Cement : 5 Fine Sand:10 Graded Stone Aggregate 40 Mm Nominal Size ) And Inside Plastering With Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) 12 Mm Thick, Finished With A Floating Coat Of Neat Cement Complete As Per Standard Design : With Common Burnt Clay F.P.S. ( Non Modular ) Bricks Of Class Designation 7.5 ( Rate Only ) 330 Air Valve & Water Meter ( Bulk Type ) : Providing And Fixing C.I. Double Acting Air Valve Of Approved Quality With Bolts, Nuts, Rubber Insertions Etc. Complete ( The Tail Pieces, Tapers Etc If Required Will Be Paid Separately ) :50 Mm Dia 331 80 Mm Dia 332 100 Mm Dia 333 Providing And Fixing Enclosed Type Water Meter ( Bulk Type ) Conforming To Is : 2373 And Tested By Municipal Board Complete With Bolts, Nuts, Rubber Insertions Etc. ( The Tail Pieces If Required Will Be Paid Separately ) :150 Mm Dia Nominal Bore 334 200 Mm Dia Nominal Bore 335 Providing And Fixing C.I. Dirt Box Strainer For Bulk Type Water Meter With Nuts, Bolts, Rubber Insertions Etc. Complete Conforming To Is : 2373 :80 Mm Dia 336 100 Mm Dia 337 150 Mm Dia 338 200 Mm Dia 339 Providingandlayings&Sc.I.Standardspecialssuitablefor Mechanical Jointing As Per Is : 13382 :Up To 300 Mm Dia 340 Filter Feedpump :Providingand Fixing Vertical, Inline Multistage Centrifugalpumpingset ( Complete Manufactured Skid-Mounted Arrangement With Manifold And Accessories ) Withstainlesssteelss-304Stage Casingandss-304Impellerswith Stainless Steel Shaft As Per Iec Standards And Gjl250 Cast Iron Suction & Discharge Casing, Connected To Tefc Ventilated Induction Motor Of 2 Pole, 2900 Rpm, Suitablefor 400 / 440 Volts, 3 Phase, 50 Hz A.C. Supply With Pressure Gauge And With Gunmetal Isolationcocks, Vibrationelimination Pads Etc. Complete With Base And Frame, Nuts And Boltsandnecessary Rcc Foundations As Per Requirementasper Instructionsandpumpshallhave Following Duty: A ) .No. Ofpumps: 3 ( 2 Working + 1 Standby ) B ) .Capacity :2000 Lpmc ) .Head :35 Md ) .Capacity :2000 Lpm E ) .Hp ( Motors ) : 75 Hp 341 Pressure Filter ( Domestic Water ) :Providing And Fixing Vertical Dual Media Pressure Filter ( Comprising Of Minimum 300Mm Bed Depth Of Anthracite And Support Media And Minimum Height On Straight 2500Mm ) Fabricated From High Performance M.S Plate Of Minimum 10Mm Thick For Shell & 12Mm Thickfor Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Internally Treated With Coal-Tar Epoxy, Complete With Air Scouring, Collection System Complete With Initial Charge Of Media, M.S Facepiping, Valves, Accessories, External Painting With 2 Coats Of Red Oxide Primer And Enamel Paint, Testing And Commissioning Complete. ( Tested To 5.0 Kg / M2 ) A ) .Discharge : App.120000 Lph ( Each ) B ) .Filtration Rate : 24, 500 Lit. / M2 / H C ) .Each Suggested Dia App.:As Per Manifacture Detail 342 Water Softener:Providing And Fixing ‘Cation’ Ion Exchange Water Softener Fabricated From Minimum 10Mm Thick M.S. Plateon Min. Shell And 12Mm Thick M.S. Plate On Dished Ends ( Quality Of Steel As Per Is:2062 Grade B, Thickness As Per Asme Section 8 ) Complete With Initial Charge Of Filter Media And Ion Exchange Resins, Face Piping Accessories, Diaphragm Valves Of Approved Specifications, Hdpe Brine Tank Of Min. 500 Liters, Piping Testing And Commissioning Complete With Resins Of Approved Quality And Make And Regeneration Assembly Complete With Valves, Ejector, Brine Suction Valves And Piping. ( Bidder Must Indicate Type And Quantity Of Resin Used And Quantity Of Salt Required Per Regeneration ) . All Internal Parts Of The Softener Shall Be Rubber Lined As Per Approved Specifications.A ) .Minimum Expected Rate Of Flow:App.32, 000 Lph B ) .Total Soft Water To Be Produced Between Two Regenerations: App. 256 Cu.M C ) .Expected Raw Water Hardness : App. 450-500 Ppmd ) .Expected Treated Water Hardness: Less Than 5 Ppm ( Zero Commercial Hardness ) E ) .Max. Working Pressure: 4 Kg / Cm2 343 Cubical Panel Board - Plumbing : Supply, Installation, Testing And Commissioning Of Cubical Type Sectionalised Floor Standing Switch Board Of 31 Mva Fault Capacity At 415 V Complete With 3.5 Strip, 160 A Capacity Aluminium Bus - Bar Electrolytic Grade, Cable Alley, Switchgears Of Following Capacity & As Per Specifications.Incomer : 600 A Tp Mccb With Heavy Duty Solid Neutral Link With ( 0-100A ) Ammeter With 3 Ct And Selector Switch, ( 0 - 500 V ) Voltmeter With Selector Switch, Phase Indication Light Withprotection Fuse. - 01 Setoutgoings : I ) For 5 X 75 Hp Domestic Water Fixed Speed Hydroneumatic Pumps ( 1 Duty + 1 Stand By ) Ii ) For 2 X 5 Hp Sump Pump ( 1 Duty + 1 Stand By ) 150 A Tp Mcb With 40 A Dol Starter, Overload Relay, 96 Mm ( 0-40A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01Set. 40A Tp Mcb With 25 A Dol Starter, Overload Relay, 96 Mm ( 0-25A ) Ammeter With Single Ct, Start / Stop Push Buttons, On / Off / Trip Indication Lights With Protection Fuse, Single Phase Preventer. - 01 Set.
Contract Date: Ref. Documents Contract Value : Ref. Document
Government Departments No of Bidders 3
Uttar Pradesh View Result →
10.
Home Affairs #8870397 Technical Bid
Annual Maintenance Contract Of Window Type , Split Type And Tower Type Air Conditioners Installed At Ss Bn , Itbp Saboli , Sonepat ( Haryana ) For The Year 2021 22 Amc Of Window Type , Split Type And Tower Type Air Conditioners Installed At Ss Bn , Itbp Saboli , Sonepat ( Haryana ) For The Year 2021-22 , Amc Work Of Split Type , Window Type And Tower Type Acs , 1 . 0 To 4 . 0 Tonne : Running And Comprehensive Maintenance Of 1 . 0 To 2 . 0 Tonne Window Type Air-Conditioners Of All Makes Installed At Ss Bn Itb Police Saboli Including Repair / Replacement Of Pcb Circuit Filter , Motor , Compressor , Servicing , Gas Filling / Refilling , And Replacement Of Other Parts Of The Unit If Required Complete Etc . Whenever Required As Per Terms And Condition W . E . F 01 / 04 / 2021 To 31 / 10 / 2021 ( 24 Ac X 7 Month=168 Ac ) , Running And Comprehensive Maintenance Of 1 . 0 To 2 . 0 Tonne Spilt Type Air Conditioners Of All Makes Installed At Ss Bn Itb Police Saboli Including Repair / Replacement Of Pcb Circuit Filter , Motor , Compressor , Servicing , Gas Filling / Refilling , And Replacement Of Other Parts Of The Unit If Required Complete Etc . Whenever Required As Per Terms And Condition W . E . F 01 / 04 / 2021 To 31 / 10 / 2021 ( 24 Ac X 7 Month=168 Ac ) , Running And Comprehensive Maintenance Of 4 . 0 Tonne Tower Type Air-Conditioners Of All Makes Installed At Ss Bn Itb Police Saboli Including Repair / Replacement Of Pcb Circuit Filter , Motor , Compressor , Servicing , Gas Filling / Refilling , And Replacement Of Other Parts Of The Unit If Required Complete Etc . Whenever Required As Per Terms And Condition W . E . F 01 / 04 / 2021 To 31 / 10 / 2021 ( 3 Ac X 7 Month=21 Ac )
Contract Date: Ref. Documents Contract Value : Ref. Document
Statutory Bodies & Commissions/Committees No of Bidders 4
11.
Defence #8411800 AOC
Tender For Day To Day Maintenance Misc Repairs At 42 Weu And Repairs To Cooling Appliances Internal Electrification And Water Supply Distribution Line At 42 Weu At Sac Under Ge Af Tvm; 1 Day to day maint at Pkt A, B, D & E and petty repair services at HQ SAC Trivandrum. 2 Checking of joinery (wooden/steel) iron/aluminium mongery, pelmet box, door springs etc requiring carpentry work and carrying out minor repairs such as tightening of screws/nails, minor adjustment of joinery, door /windows by means of planer/chisling etc. including petty repairs material like screws/nails, plug etc. to make it functional.Note : Any items required to be replaced shall be paid under respective items and in that case this items shall not be measured and paid. 3 S&Fin repairs 25mm dia decorative anodised Aluminium curtain rodsincluding supporting brackets and end caps/dome complete all as specified and directed 4 Hacking out old broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins or spring clips and providing and fixing new clips or pins. complete all as specified and directed 5 S&F in repairs looking mirror 600mmx450mm beveled edge 5mm thick selected quality glass, mounted on 6mm thick commercial plywood, aluminum frame around and fixed to wooden plugs with chromium plated brass screws and cup washers complete. 6 S&F in repairs aluminium alloy sliding door bolt 250 mm long with hasp, staple ( bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy.complete all as specified and directed 7 S&F in repairs 150mm extruded brass handles fabricated and polishedcomplete all as specified and directed 8 S&F in repairs 150 mm aluminium handles, cast type, anodised.complete all as specified and directed 9 S&F in repairs 125 mm aluminium handles, cast type, anodised. complete all as specified and directed 10 S&F in repairs 200 mm long brass tower bolts complete all as specified and directed 11 S&F in repairs 200 mm long aluminium anodised barrel tower bolts of extruded section. complete all as specified and directed 12 S&F in repairs 150 mm long aluminium anodized barrel tower bolts of extruded section. complete all as specified and directed 13 S&F in repairs brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges. complete all as specified and directed 14 S&F in repairs stainless steel butt hinges medium weight 100 mm long fixed to pressed steel/angle iron frames by welding. complete all as specified and directed 15 S&F in repairs Aluminium CP towel ring fixed with flanges and brackets as per specifications complete all as specified and as directed 16 S&F in repairs to decorative 150mm brass mortice lock complete all as specified and directed 17 S&F in repairs decorative brass handles (size not exceed 300mm) for doors including mortice lock complete all as specified and directed 18 M & L 18/19mm thick Prelaminated plywood, prelaminatedon both sides with decorative choice laminations, fixed with screws to incupbords, warddrops, kitchen covered cabinetetc around the plywood/ teakwood lipping shall be finished with two coats of French polish. 19 Taking down chowkats or frames (without taking off shutters from frame) not exc 1.50 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and directed 20 Taking down chowkats or frames (without taking off shutters from frame) exc 1.50 Sqm and not exc 4.00 Sqm each including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish without any extra cost to Govt.)complete all as specified and directed. 21 Taking down Shutters of any description exc 1.0 sqm and n.exc 2 sqm each, resecuring or easing and refixing in the same opening, including finishes complete all as specified and directed 22 Taking down Shutters of any description n.exc 1 sqm each, resecuring or easing and refixing in the same opening, including finishes complete all as specified and directed 23 S&F plain, solid, 2nd class hard wood straight chowkats and frames wrought framed rebated on the solid, rounded or chamfered put together with pinned at joint etc complete. 24 S&F 75 mm longstainless steel butt hinges, medium weight, cold rolled and fixed. complete all as specified and directed 25 S&F 100 mm long stainless steel butt hinges, medium weight, cold rolled and fixed. complete all as specified and directed 26 S&F 150mm long aluminium, anodised, barrel tower bolts of extruded section and fixed. complete all as specified and directed 27 S&F 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed. complete all as specified and directed 28 S&F 100 mm long aluminium handles, cast type, anodised and fixed. complete all as specified and directed 29 S&F 150 mm long aluminium handles, cast type, anodised and fixed. complete all as specified and directed 30 S&F in repairs floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring,size 140 mm.anodised with hard drawn steel spring overall length suitable for aluminium/wooden door complete all as specified and directed 31 S&F in repairs floor door stopper of brass body and tongue, anodised with hard drawn steel spring,size 140 mm.anodised with hard drawn steel spring overall length suitable for aluminium/wooden door complete all as specified and directed 32 S&F in repairs door closers of aluminium die cast bodyhydraulically regulated designation No 2, universal type, suitable for door shutters of 800 to1000 mm in width and of weight between 61 to 80 kgs and fixedcomplete all as specified and directed 33 S&F 4.80 mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads in squaresexceeding 0.50 Sqm in each pane.complete all as specified and directed 34 Checking and attending to water leakage from taps, flushing cisterns, wash hand basins and other sanitary fittings/fixtures and any obstruction to water supply, requiring plumber work andcarryout minor repairs such as replacement of washers, check nuts, tightening of fittings of flushing cistern etc including petty materials like washers of all sizes, thread(shoot), M-seal, screws, nails to make water supply/ plumbing lines functional and leak proof.Note :Any item required to be replaced shall be paid under respective item and in that case this above item shall not be measured and paid. 35 S&F in repair pillar taps, fancy type chromium plated copper alloy, with capstan heads, chromium plated, fancy type ,screwed down high pressure, with or without lettered Hot or cold with long screwed shanks and fly nuts, screwed for iron pipe of dia 15 mmcomplete all as specified and directed. 36 S&F in repairs 15 mm stop valves/Angle cock, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipecomplete all as specified and directed 37 S&F in repairs 15 mm CP fancy type bib tap cast copper alloywith crutch or butter fly handle, scewed down, screwed for iron pipe or for brass ferruleand fixedcomplete all as specified and directed 38 Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm diacomplete all as specified and directed. 39 S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm longcomplete all as specified and directed 40 S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mmcomplete all as specified and directed 41 S&F in repair C.P. grating 100mm square/round with or without holecomplete all as specified and directed 42 S&F in repairs 32 mm dia PVC waste pipe for WHB complete all as specified 43 S&F in repairs 40 mm dia PVC waste pipe for sink, complete all as specified 44 S&F in repairs stainlesssteel toilet paper holder fixed with wooden gutties and screws to wall surfacescomplete all as specified and directed 45 S&F in repairs stainless steel soap tray fixed with wooden gutties and screws to wall surfaces. complete all as specified and directed 46 S & F in repairs, vitreous china WHBwhite, flat back, size 550x400mm with brackets, inc. cutting for & pinning in ends of brackets, inc. waste fitting, PTMT 32mm dia and pillar taps of PTMT 15mm dia complete all as specified and directed. 47 S&F in repair 10 ltr capacity PVC valveless, syphonic action type flushing cistern low level white with inlet, ball valve, float and handle including connection to pipe but fixed complete all as specified. 48 Cleaning ofwater tank capacity 500 ltrs and removing all scale and dirt etc from tanks and from mouths of circulating pipes etc complete all as specified and directed. 49 Cleaning of water tank capacity 1000 ltrsand removing all scale and dirt etc from tanks and from mouths of circulating pipes etc complete all as specified and directed. 50 S&F in repairs EWC seat cover of any pattern including cover and Mild steel chromium plated hinging devices of any colour all as specified and directed. 51 S&F in repairsPVCwater tank cover of any pattern,colourand any size complete all as specified and directed. 52 S&F in repairs health faucet, CP with flexible pipe of bore 15mm with necessary holder , screws and fasterens fitted to wall complete all as specified and directed. 53 Supply & fixed (in repair) vitreous china wash down water closet pedestal pattern (EWC) , White including connection to trap and to flushing pipe with ‘P’ or ‘S’ trap, making good to floor, plastic water closet seat cover with mild steel chromium plated hinges and Health Faucet with pipe complete all as specified 54 S & F in repair 3 layer (white colour) 500 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as in repairs after removing existing damaged water tankall as specified and directed 55 S & F in repair 3 layer (white colour)750 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as in repairs after removing existing damaged water tankall as specified and directed 56 S & F in repair 3 layer (white colour)1000 ltrs capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position as in repairs after removing existing damaged water tankall as specified and directed 57 S & F in repair 25 mm bore,ball valves high pressure of PTMT with epoxy coated aluminium rod &high density plastic ball screwed for iron pipe and fixed .(Minimumweight 15mm-142 gms/20mm -210 gms/25mm -455 gms/40 mm-690 gms) complete all as specified and directed 58 S&F in repairs spindle for stop cock complete all as specifed and directed. 59 Cleaning of pipes of any dia after opening of bib taps, stop cock, angle cock, pillar taps and gate valve etc and refixing in same position after cleaning of pipes complete all as specified and directed. 60 S&F in repairs tank connector, PVC suitable for fixing to outlet pipe of any description and 32mm dia bore commplete all as specified and directed. 61 S&F in repairs PVC gate valve with handle, fixed both end for PVC pipe of 32mm dia bore complete all as specified and directed. 62 S & F in repairs 125 mm size chromium plated brass shower rose with or without swivel joints and swivel arms for fixing with 15 mm dia bore pipe complete all as specified and directed. 63 S & F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed 64 S & F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed 65 M&L for preparation of new woodensurfaces of any description, not otherwise described over 10 cms width or girth and applying two coats of synthetic enamel paintoveronecoat of pinkprimercomplete all as specified and directed 66 S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed in wooden windows, doors and upvc windows with beading, aluminium wire staples and necessary arrangement also including necessary scaffolding wherever is required Note : Work in G+4 building Scaffolding shall be included in quoted rate complete all as specified and directed. 67 Dismantling of stone slabs and tiles of any description or thickness laid bedded and pointed in any mortar in floors, aprons etccomplete all as specified and directed 68 M&L for Granite (of any type) work ,20 mm thick, (table rubbed and polished) in steps jambs , pillars ,window cills ,cooking platforms ,and the like in cement mortar (1:4) including pointing in white cement (1;2) using marble dust with admixture of pigment to match with shade of granite including 10 mm thick screed bed in CM 1:4 complete all as specified and directed 69 Repair to aluminium door or window of any size, shape and description including easing, cutting, drilling, including provn of parts such as rubber gasket, blanket cloth, etc to make door or window fully functional complete all as directed by Engr-in- Charge. 70 Taking down cement or cement lime plaster of any description on brick or stone walls, ceilings etc.including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed 71 M&L for Rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 including finished the surface even and smooth with out using extra cement complete all as specified and directed. 72 M&L for rendering 15mm thick on fair face of brick work or concrete surface in CM 1:6including finished the surface even and smooth with out using extra cement complete all as specified and directed. 73 M&L for rendering 5mm thick on fair face of brick work or concrete surface in CM 1:3including finished the surface even and smooth with out using extra cement complete all as specified and directed. 74 M&L for preparation of new plastered surface of wall and applying two coats of oil emulsion distemper on wall over a coat of primer complete all as specified and directed. 75 M&L for preparation of new plastered surface of wall and applying two coats of weather coat paint over a coat of primer complete all as specified. 76 M&L for preparing new plastered surface of ceiling and applying two coat of white wash on ceiling all as specified and directed 77 S& F in repairs basin mixer with 450mm braided connection pipecomplete all as specified and directed by Engr-in-Charge.Make :Jaquar/CERA/Prayag or equivalent 78 S& F in repairs brass chormium plated 3 in 1 wall mixer wth the provision of overhead shower and telephonic shower arrangementcomplete all as specified and directed by Engr-in-Charge.Make :Jaquar/CERA/Prayag or equivalent 79 M&L for arresting Leakage of joint of UPVC/PVC/CPVC pipe of any size with solutioncomplete all as specified and directed 80 Removing basin mixer/ wall mixer and refixing in the same position after repairs/replacement of washer/plunger for arresting leakages including cleaning etc complete all as specified and directed. 81 Taking down glass corner shelf/straight glass shelf and refixing with new CP bracket and fitting with screws, complete all as specified and directed. 82 Fixing only Bib tap 15mm complete all as specified and directed. Note : Item to be procured from 83 Fixing only 600mm towel rail complete all as specified and directed 84 Fixing only 150mm Aluminium handle complete all as specified and directed 85 Fixing only 15mm concealed stop cock complete all as specified and directed. Note : Item from Sl No 81 to 84 should be issued under Schedule - B 86 Dismantling of broken laterite tile including cement mortar and fixing of new laterite tile of any size (as per site) over CM 1:3 on vertical surfaces complete all as specified and directed. 87 Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similarpattern roof coverings complete all as specified and directed. 88 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 89 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick but except sheeting of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed. 90 Taking down of rain gutter pipe and refixing after cleaning and including brackets/fittings wherever is rquired complete all as specified and directed 91 Removing urinal waste coupling & pipe and refixing after arresting leakage including cleaning of waste coupling, complete all as specified and directed 92 Repairs to broken water pipe line including fittings as required, complete all as directed by Engr-in-charge. Note : Contractor must employ Plumber at urgent basis whether it may be day or night failing to which penalty will be imposed against the contract amount 93 Removing Push stop cock of urinal and refixing after replace plunger/washer including cleaning complete all as specified and directed. 94 M&L for removal of tree/bush from holes in walls and repair with CM 1:3 including WPC compound and including necessary scaffolding wherever is required, complete all as specified and directed. 95 Taking down Toughened glass door/Partition any size and refixing after making good including replacements of handles, brackets and necessary fittings wherever is required,complete all as specified and directed. 96 S&F in repairs aluminium weather strip with Nylon brush insert suitable for bottom of door shutters of wooden/aluminum all as specified and directed. 97 S & F in repairs Brass, 2 lever, locks, drawer, grade-I of 50 mm size complete all as specified and directed. 98 S & F in repairs mild steel 2 lever mortice lock, vertical type 100 mm size complete all as specified and directed. 99 S & F in repairs mild steel 4 lever mortice lock, vertical type 100 mm size complete all as specified and directed. 100 S&F in repairs 75mm long half folded auto hingescomplete all as specified and directed. 101 S&F in repairs venetian blind using cotton/Nylon fabric of size as required for windows/ Ventilators horizontally rolling up and down with double layer cloth including rolling device on top and power coated aluminium double layer pipe at bottom, incl operating rope etc all as specified and directed. 102 S&F in repairs bathroom cabinet with mirror 250x400 mm size, complete all as specified and directed. 103 S&F in repairs Solar control film 50micron reflective type sticked to glass panes as per instructions of manufacturers all as specified and directed. 104 S&F in repairs flush pipe of Polyethylene low or high density PVC 32mm dia for low level including fixed to WC and cistern complete all as specified and directed. 105 Taking down towel rail of any description from the wall and refixing after tiling work complete all as specified and directed 106 Taking down PVC cabinet of any description from the wall and refixing after tiling work complete all as specified and directed 107 Repairs only to flush pipe, soil waste pipe of WC for arresting leakage by providing bushes, washers, white cement, putty etc complete all as specified and directed. 108 Arresting leakage from joints between sink and granite slab by providing white cement, putty, M Seal etc complete all as specified and directed. 109 Repairs only to high/low level flushing cistern and arresting leakage of its internal fittings/washers complete all as specified and directed. 110 S&F in repairs internal fittings such as ball valve and float for flushing cistern complete all as specified and directed. 111 S&F in repairs complete set ofinternal fittings of Cascade type EWC for arresting leakage complete all as specified and directed. 112 S&F in repairs PVC eaves gutters half roundwith rounded edges of dia 110mm thickness of sheet 1.25mm complete all as specified and directed 113 S&F in repairs PVC eaves gutters half roundwith rounded edges of dia 75mm thickness of sheet 1.25mm complete all as specified and directed 114 Certain repairs/ Maintenance to complaints of B/R works and internal watersupply, sanitary fitting at 42 WEU at AF area TVM 115 Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing . 116 S&F unplasticised PVC pipes 20 mm bore of prerssure rating 10 kgf/sqcm fixed complete to wall, ceiling or in floors any type of pipe 117 Supply andfixed in repairs Vitreous chinawash down water closet pan (Pedestal pattern), white,excluding flushing cistern 118 S & Fin repairs 200 mm long aluminium, anodised, barrel tower bolts of extruded section, ISI marked, complete all as specified and directed. 119 S&F in repairs extruded aluminium alloy handles, fabricated type, anodised of size 150 mm long complete all as specified and directed. 120 S&F plain sheet glass 3 mm thick ordinary quality and glazing with oil putty/beading etc n.exc 0.50 Sqm each all as specified including removal of old broken glass 121 S&F in repairs Vitreous China wash basin, white, flat back, size 550x400excluding taps, waste, chain and plug andporcelainstopper but including brackets complete all as specified and directed 122 S&Fixed in repairs looking mirror 600x450 mm size Covered with aluminium frame with ply wood/black board/AC building board fixed with screw 123 S & Fixed in repairs PVC (SWR) Floor trap of 75 mm outlet plain with grating including jointing with solvent cement. 124 S & F 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed on walls 125 S & F 110 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints lfixed on walls 126 S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, fancy type, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe. 127 S & F Brass chromium plated showerrose 125mm size with or without swivel joints any size including fixing to steel pipe or union 15mm bore,fixed in repair. 128 Supply and fix PVC (SWR) branch piece double(double Y) equal or unequal 110mm dia 129 Supply and fix PVC (SWR) bends 75mm diaany radius. 130 Supply and fix PVC (SWR) bends 110mm diaany radius. 131 Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing ,removing serviceable tiles to store and rubbish off the premises. 132 M&L cement concrete type B0, 1:2:4 25 mm thick using 12.5 mm graded aggregate as in sub base for floor. 133 M&L Screed bed or bedding layerin cement mortar 1:4 15mm thick for laying floor finishes 134 S & F coloured ceramic tiles 7 t0 8mm thk (square /Rectangular ) area of each tile exc 0.06 sqn and n.exc 0.11 sqm ,in floors etcset and jointed in neat cement slurry and pointed with white cement or pigment to match with the shade of the tilesall as specified and as directed byEngineer-in-Charge. 135 M/L10mnm thick plastering in cement mortar 1:4 as backing coat for receiving finishes as skirting /dado. 136 M&L Coloured Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match 137 S&F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with aluminium wire staplescomplete all as specified and directed. 138 S & F in repair alumimum extruted section body door closer hydraulically regulated, designation No 2, universal type, suitable for door shutters of 801 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. 139 S&F mild steel work as framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. 140 S&F in repairs stop cock fancy type cast copper alloy (concealed type) 15 mm borescrewed down high pressure, with crutch or butter fly handle screwed both ends for pipe or for unions complete all as specified and directed by Engineer in charge. 141 Repairs to drain, fencing, compound all/retaining wall, footpath and cleaning of septic tank, manholes sewage line at 42 WEU at AF area Trivandrum. 142 M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan exc 6m meanradius built in CM 1:6, complete all as specified and directed. 143 M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in built in CM 1:4, complete all as specified and directed. 144 M&L forPre-cast cement concrete block (PCC 1:3:6 Type C-1) masonry with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and directed. 145 M&L for Boulder pitching, pitching is grouted with cement and sand mortar 1:6, complete all as specified and directed.Note : Thickness of stone shall be 20cm. 146 M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, builtin CM 1:6 complete all as specified and directed. 147 M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, builtin CM 1:6 (Except stone) complete all as specified and directed. 148 Demolition of brickwork/blockwork or stone/ boulder masonry, built in cement or cement lime mortar including allquoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. 149 M&L for chequered cement concrete tiles 300x300x20mm thick set and jointed and pointed in neat cement slurry in floor with grey cement and no pigment complete all as specified and directed. 150 M&L 75mm thick PCC 1:4:8 type D2, using 40mm graded stone aggregate as in floors complete all as specified and directed. 151 M&L for 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 complete all as specified and directed. 152 Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar complete all as specified and directed. 153 S&F Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and no pigment. complete all as specified and directed. 154 -ditto- same as tem No.153 butexcept tiles complete all as specified and directed. 155 Supply and spreading coarse aggregate from 12.5mm to 4.75mm not exc 25cm thick complete all as specified and directed. 156 Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole not exceeding 15mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system with manual labour (rodding manually) or by mechanically sewage suction pump (at contractor;s discretion as required at site) making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed by Engineer-in-Charge. Note :- Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government 157 Material and labour for Cleaning of existing sewage system/pipe line 100/150/200mm dia (length of pipe line manhole to manhole exceeding 15mtr but not exceeding 30mtr) including cleaning of manholes (any type rectangular/square/circular) located in different situations/sites, taking off the manhole cover (CI or RCC) and placing in the same original position after getting out liquid/sludge/solid contents from the manholes/sewage line and complete perfect function/running/flowing condition without any obstruction by removing all blockage in system by mechanically sewage suction pump making it fully functional to the entire satisfaction of Engineer-in-charge including removing of all wastes, solid or liquid sludge through closed container and depositing the sludge in a pit (at empty/open area) of suitable size from the line/clony area where directed and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases including all excavations and earthwork complete all as specified andas directed by Engineer-in-Charge. Note :- Disposal of the same shall be the responsibility of the Contractor. Disposal of waste shall be made in accordance with the regulations of authorities concerned without any extra expediture to the Government 158 CleaningSWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 75mm dia pipe in vertical walls/floors complete all as specified and directed. 159 CleaningSWG/PVC/CI pipe sewage line manually or mechanically using cleaning rod or compressor and removing foreign material after clearing existing blockage for 110mm dia pipe on vertical walls/floors complete all as specified and directed. 160 Material and labour for Cleaning/removal of blockage from bathroom, kitchen, WHB and urinals including connected Nahani traps / gully traps/floor traps, grating of trap, waste pipes, pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers, refixing manhole covers and for making good damaged surfaces of sorroundings of nahani trap, Gulli trap/floor traps etc with CM 1:3 or white cement complete all as directed by Engineer in Charge. Note :- Obtained waste materials shall be disposedto a distance not less than 100 mtrs as directed by Hygenic authorities) and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases complete all as specified and directed. 161 Material and labour for Cleaning/removal of blockage from EWC/IWC (any type) including connected traps (any type), pipe in any length upto Ist manhole etc choked with mud / other accumulated sludge and getting out, washing thoroughly at any location, at any floor by rodding/choke remover/Pressure technique/manually or otherwise to clear blockage upto entire satisfaction of users,including refixing of oval assess door covers with new nuts & washers andrefixing manhole covers, complete all as specified andas directed by Engineer-in-Charge. Note :- Obtained waste materials shall be disposedto a distance not less than 100 mtrs as directed by Hygenic authorities) and covering the same with the soil obtained from excavation of pit after treating the sludge by spreading the bleaching powder as directed to reduce the foul gases complete all as specified and directed. 162 S&F in repairs150 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in walls or floors complete all as specified and directed 163 M&L for cement concrete bed to drain pipe 150 mm dia in cement concrete 1:3:6 type C2 including packing under the haunching on sides all as directed and specified 164 S&Fin repairs 50mm bore Unplasticized PVC pipes of pressure rating 10 kgf/sqcm in repairs complete all as specified and directed 165 S&Fin repairs 75 mm,bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc and including necessary scafolding where is required, complete all as specified and directed. 166 S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls, ceilings or in floors etc and including necessary scafolding where is required, complete all as specified and directed. 167 S&F in reapirs PVC (SWR) gully trap 125/110 mm setting and jointing with solvent cement and making good the surfaces all as directed and specified 168 S & F in repair 110 mm bore PVC(SWR) bends of any radius etc, complete all as specified and directed . 169 S & F in repair 110 mm bore PVC (SWR) junction single,(Single T) equal or unequal etc, complete all as specified and directed . 170 S & F in repair 75 mm bore PVC(SWR) bends of any radius etc, complete all as specified and directed . 171 S & F in repair 75 mm bore PVC (SWR) junction single,(Single T) equal or unequal etc, complete all as specified and directed . 172 Supply and fixed in repair SFRC (Steel fibre reinforced concrete) cover and frame (heavy duty HD-20 grade designation) sizeof cover 600 x 600mm/ 700 x 700mmconfirming to IS 12592, fixed in cement concrete 1:2:4, complete all as specified and directed. 173 Maint/ Repair to cooling appliances refrigeration at HQ SAC under GE (AF) Tvm 174 M&L Servicing of indoor unit of split type AC of 1.0 to 3.0 Ton Capacity of any make by air blowing, cleaning the filter in water and drying in sun, cleaning of drain tray and rectifing water leak, checking and tightning the electrical connection all as directed. 175 M & L for servicing of outdoor unit of Split type air conditioner of1.0 to 3.0 Ton capacity any make by compressed air and water washing,descaling of condeser coil and oiling of outdoor fan motor, checking and tightning of all the electrical connections, nuts, bolts, washers all as specified and as directed. 176 M & L for painting of outdoor unit of Split type air conditioner of 1.5/2.0/3.0 ton capacity any make including preparation of old painted surfacecomplete and painting with one coat of Synthetic enamel paint complete in position all as specified and as directed. 177 M& L for stickering of MES/SM Nos on indoor and outdoor unit of any type of air conditioning in any location all as directed. 178 M& L for Removing the Split type AC 1.0 ton to 2.0 Ton, by taking out from the existing position after pumping down gas from position with frame, outdoor / indoor unit carefully, shifting to new position, cutting opening wall of required size & fix in new position, topping up of gas and making good distrubed surface of wall opening by plastering and appling white wash including closing the old opening making good distrubed surface plastering and appling white wash all as required and directed 179 M& L for Removing the Split type/ tower / cassette typeAC 3.0 ton to 4.0 ton capacity after pumping down gas from position, refixing to new position alongwith and charging of gas in the compressor after rectifing leak and rat cutting complete all as directed. 180 Supply and charge of gas R-410/R32 for inverter typre split AC of 1.0/1.5/2.0/3.0/4.0 Ton capacity after leak testing and rectification of leak all as specified & directed. 181 Supply and charge of gas R22/R134a to Split AC,Tower AC, Cassette Type AC of 1.0/1.5/2.0/3.0/4.0 Ton capacity after leak testing and rectification of leak all as specified & directed. 182 M&L for taking out old unserviceable capillary and stainer from refrigerator and supply and fix new capillary & stainer of any capacity.all as specified and as directed. 183 All as per item No 182 above but for inverter typre split AC and split type AC 1.0/1.5 /2.0 Ton capacity. 184 Servicing of refrigerator by air blowing, cleaning of condensor coil, rubber bedding & checking and tightning the electrical connection all as directedof capacity 165to 430 Ltrs all as specified and as directed. 185 Servicing of water cooler by air blowing, cleaning of condensor coil, checking and tightning the electrical connection all as directed for water cooler of capacity 40/80 ltrsall as specified and as directed. 186 Supply and fix in replacement of outdoor capacitor 36 + 5% uFD 187 Supply and fix in replacement of outdoor capacitor 46 + 5% uFD 188 Supply and fix in replacement of outdoor capacitor 62 + 5% uFD 189 Supply & replace timer switch for refrigerator of any capacity all as specified and directed. 190 Supply & replace bimetal switch for refrigerator of any capacity all as specified and directed. 191 Removing defective over load protector and supply and fixing new over load protector for Deep freezer/ refrigerator of any capacity and testing completeall as specified and as directed. 192 Supply and fix in replacement of defective fan motor with new fan motorsuitable for water cooler/deep freezer of any capacity and testing complete all as directed. 193 All as per No 192 above but forouter unit of split AC 1.5 Ton capacity all as specified and directed. 194 All as per No 192 above but forouter unit of split AC 2.0 Ton capacity all as specified and directed. 195 All as per No 192 above but forouter unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. 196 All as per No 192 above but forouter unit of inverter type split AC of 2.0 Ton capacity all as specified and directed 197 All as per No 192 above but forinner unit of split AC of 1.5 Ton capacity all as specified and directed. 198 All as per No 192 above but forinner unit of split AC of 2.0 Ton capacity all as specified and directed. 199 All as per No 192 above but forinner unit of inverter type split AC of 1.5 Ton capacity all as specified and directed. 200 All as per No 192 above but forinner unit of inverter type split AC of 2.0 Ton capacity all as specified and directed. 201 All as per No 192 above but swing motor of split AC 1.5 /2.0/3.0 Ton capacity all as specified and directed. 202 M&L for rewinding of defective outdoor unit fan motor of split type AC 1.0/1.5/2.0 ton capacity any capacity and testing complete all as directed. 203 Removing and Repairs to electronic control PCBfor split type AC 1.0/1.5/2.0 ton capacity of existing make all as directed. 204 All as per item No 203 above but for mega split, towerAC type AC 3.0/ 4.0 ton ton capacity all as specified and directed. 205 All as per item No 203 above but forinverter type split AC of 1.0/1.5 ton capacity (outdoor & indoor) of existing make all as directed. 206 Supply and fix in repairs electronic control PCB with panel for 3.0/ 4.0 ton Tower/cassette type AC of existing make all as directed. 207 Supply and replace electronic control PCB for Smart Inverter Refrigerator all as directed. 208 Supply and replace sensor / anti ice thermostate for split type ACof any model all as directed. 209 Supply and replace remote unit for split type ACof any model all as specified and directed. 210 Supply and replace remote battery 1.5 Volts for split type ACof any model all as specified and directed. 211 supply and fix in repairs compressor suitable for split type AC 1.5 Ton capacity by removing unserviceable compressor after cutting the refrigerant line including supply and fixing new hermetically sealed compressor unit suitable to operate on 230 volt AC including connecting back the suction & discharge refrigerant lines, vaccumising charging of refrigerant testing and commissioning for smoot functioning all as specified & directed. 212 All as per item No 211 above, but for 2.0 Ton capacity all as specified and directed. 213 All as per item No 211 above, but for 4.0 Ton Tower AC capacity all as specified and directed. 214 All as per item No 211 above, but for inverter type split AC of 1.5 Ton capacity all as specified and directed. 215 All as per item No 211 above, but for inverter type split AC of 2.0 Ton capacity all as specified and directed. 216 All as per item No 211 above,but for split type AC 3.0 ton/4.0 Ton capacity, 425 Volts 3 phase all as specified and directed. 217 Supply and fix push tap CP brass, 15 mm suitable for water cooler of any capacity all as specified and directed. 218 Material and labour for repair of voltage stabilizer after removig the burnt out unserviceable winding cleaning the slots, insulate properly and rewindingtransformer including testing of capacity 5 KVA, single phase, 230 V AC, 50 Hz all as specified and directed. 219 All as per item No 218 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed 220 Material and labour for repair of voltage stabilizer by replacing time delay relay /main relay unit of voltage stabilizer with new of capacity 5 KVA, 4KVA including testing complete all as directed. 221 All as per item No 220 above, but of capacity 3/ 2 /1/0.5 KVA all as specified and directed. 222 Supply and replace service valve for split type AC of 1/4 Size all as specified and as directed. 223 Supply and replace service valve for split type AC of1/2 Size all as specified and as directed. 224 Supply and replace service valve for split type AC of5/8 Size all as specified and as directed. 225 Supply & replace condenser unitfor split AC of the following type and any make / capacity all as specified and as directed: 226 1.5 Ton capacity 227 2.0Ton capacity 228 Supply & replace outer body kit for split type AC of following capacities complete with condensor coil and fan motor complete of existing make all as specified and directed. Note: Compressor, condensor coils and fan motorwill be measured and paid separately. 229 1.5 Ton capacity 230 2.0Ton capacity 231 Supply and replace copper pipe 1/4all as specified and as directed. 232 Supply and replace copper pipe 1/2all as specified and as directed. 233 Supply and replace copper pipe 3/4all as specified and as directed. 234 Supply and replace copper pip 5/8all as specified and as directed. 235 Supply and replace flair nut 1/4all as specified and as directed. 236 Supply and replace flair nut 1/2all as specified and as directed. 237 Supply & replace drain PVCpipe for split type AC any capacity all as directred. 238 Supply and replace PC Board of indoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as directed 239 Supply and replace PC Board of outdoor for inverter type split AC of 1.5 to 2.0 ton capacity of existing make all as directed 240 S & F Grill for enclosing the outer unut of air conditioners of any capacity 241 Supply & fix flexible PVC pipe for drinking purpose of any dia suitable for any type of water cooler 242 Supply & replace MS/GI bracket for fixing of outer unit of Air conditioners of capacity 1.5 ton/2.0 ton all as specified and as directed 243 Supply and replace Metal plug and socket with MCB 20 Amps and steel enclosureall as specified and as directed 244 Supply and replace MCB SP5 to 30 Amps 230 Vall as specified and as directed 245 M&L for sub main wiring surface/ concealed type including cutting chases and making good in CM 1:3 complete with (2 runs of 4 Sqmm for phase and neutral and one run of 2.5 Sqmm for earth continuity) 1100 Volts grade PVC insulated unsheathed single core multistranded cable FR grade with copper conductorconfirming to IS 694 drawn inconduit including provision of suitable dia PVC rigid conduit (medium grade) with conduit accessories such as bends, elbows, saddles all as specified and as directed. 246 Ditto as per item ser No 245here in after but for4x6.0 sq. mm + 1x6.0 sq. mm earth wire All as specified 247 Supply and replace thermocool insulation for copper pipe for split type AC of any type and capacity.all as specified and as directed 248 Supply and replace unserviceable fan blade of outdoor unit fan motor of split type AC 1.0/1.5/2.0/ 3.0 ton capacity with new fan blade all as specified and directed. 249 Comprehensive Annual Maintenance Contract (AMC)of water cooler by OEM . Make :Cross field Water Purifiers Pvt Ltd (17 Qty) complete all as specified and as directed.Note : The work includes changing of filter element, PC board,UV lamp, UV choke, hose, angle cock tap including pipe connection etc as per site requirement and all as specified. 250 Supply and replace of all filter of water cooler / purifire CANTT RO or any type and capacity of existing make complete all as specified and as directed 251 Supply and installation of 3/4 PVC drain piping system for outdoor motor unit, including all necessary fittings and connections to ensure proper drainage of condensate water complete all as specified and as directed. 252 Repairs/ Replacement of internal electrification including fittings and fixtures of buildings at 42 WEUunder GE (AF) Tvm 253 Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors etc all as directed. 254 M&L for point wiring complete with 1.5 Sqmmsingle core FRLSH PVC insulated sheathed cable 1100 V grade multi stranded copper conductor drawn through and including non metallic rigid PVC conduit and accessoriesconcealed in walls/ceilings including 1.5 Sqmm dia multistranded copper cable as earth continuity conductor connected to common earth dolly, including2mmModular metal flush Box and suitable Modular white cover plate with frame andall as specified and directed. 255 One fan/light /bell point controlled by one switch/bell push 256 One switch socket outlet 5 Amps on independent board 257 One 3 pin socket outlet, 5 Amps on the same board with other swictches with cables 1.5 Sq mm size all as directed. 258 All as per Item No 257 here-in- before but with 2.5 Sqmm PVC insulated multistranded copper conductor with 2.5 sqmm cable as earth continuity conductor for power Socket on independent board on the existing/new PVC surface conduit all as directed. 259 Supply and fix in replacement switch piano flush button single pole oneway 6 amps all as directed. 260 Supply and fix in replacement socket flush type 2 in 1, 3 pin 6 amps. 261 Supply and fix switch socket combination 3 pin 5 Amps flush type in repairs. 262 Supply and fix switch socket combination 6A/16 A , 5 in 1 flush type , universal flush type. 263 Supply and fix in replacement ceiling rose surface bakelite with three terminals all as directed.Make- Anchor/Havells/Legrand. 264 Supply and fix bell push flush type 5 Amps 230V singlepole all as directed. Make- Anchor/Havells/Legrand. 265 Supply and Replaceelectric bell Ding Dong, AC 230 voltsall as specified. Make- Anchor/Havells/Legrand. 266 Supply and Replace buzzer, AC 230 voltsall as specified. Make- Anchor/Havells/Legrand. 267 S & F electronic type fan regulator rotary step 120/280 watt all as specified and directed. Make- Anchor/Havells/Legrand 268 Taking down unserviceable submain wiring and M&L for submain wiring in PVC conduit with two runs of 4 Sq mm and one run of 4 sqmm for earth continuity 1100 v grade PVC insulated unsheathed FRLSH grade copper conductor cable single core multistranded drawn through and including 25 mm dia PVC rigid connduit includung accessories such as bends, supports etc all as specified 269 Taking down unserviceable MCB distribution board, S & F SPN 4 way of any size and capacity double door with suitable busbar including disconnecting from mains and making good the disturbed surfaces all as directed.Make- Anchor/Havells/Legrand. 270 All as per item No 269 here in before but SPN 8 way. Make- Havells/Legrand/ABB 271 All as per item No 269 here in before but SPN 12 way. Make- Havells/Legrand/ABB 272 Supply and fix in replacement sheet metal enclosure distribution board for fixing MCBs with double door, TPN 4 way, 415 volts with suitable bus bar complete all as directed. Make- Anchor/Havells/Legrand. 273 Disconnecting and removing the existing metal plug and socket and and provn ofmetal plug and socket single phase two pin and earth plug with MCB, SP 20 Amps and steel enclosure. Make- Anchor/Havells/Legrand. 274 Removing of exsitingCeiling fan 1200mm sweepfrom postion, painting with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, kept in safe custodyand refixing after completion of work to postion, alongwith required accessoriesin new postion as directed 275 All as per Item No.274 above but for exhaust fan 300mm sweep including replacing of rusted nut and bolts. 276 M & L for cutting & removing the burnt winding of ceiling fan of 1200mm sweep and cleaning the slot, rewinding with super enamelled copper wire of suitable size, varnishing heating and insulating and reassembling the spares complete all as specified. 277 All as per item No. 276 above but for exhaust fan 300mm sweep. 278 Supply and Replacecapacitor 2.5 mfd suitable for ceiling fanMake – KELTRON/KEIL/BHEL/UNIVERSAL/TIBCON 279 Supply and Replacecapacitor 4 mfd suitable for exhaust fan. Make – KELTRON/KEIL/BHEL/UNIVERSAL/TIBCON 280 Disconnecting and removing the old unserviceable light fitting box type 1 x 40W / 1 x 28 Watts T-5 fitting and supply and fix new energy efficentLED batten 1 x 20 watts 4 feet long CRCA body powder coated whitebatten type MCL LED type all prewired including connection with twin core flexible PVC 0.5 Sqmm complete all as directed. Make; Havells/Wipro/Crompton 281 Disconnecting and removing the old unserviceablelight fitting box type 1 x 20W / 1 x 14 Watts T-5 fitting and supply and fix new energy efficentLED batten 1 x 10watts 2 feet long powder coated white batten type all prewired including LED tube and connection with twin core flexible PVC 0.5 Sqmm complete all as directed. Make- Havells/Wipro/Crompton 282 Removing existing Unserviceable surface mounting light fittings CFL 36 watt typeand supply and fix surface mounting LED light fittings1 x 33 / 36 watts LED panel system efficiency 36 W LED 6500 K model suitable for armstrong/grid/POP false ceiling complete all as specified and directed. Make : Havells/Wipro/Crompton 283 Removing existing Unserviceable recess mounting light fittings CFL 36 watt typeand supply and fix recess mounting LEDlight fittings1 x 33 / 36 watts LED panel system efficiency 36 W LED 6500 K model suitable for fitting infalse ceiling complete all as specified and directed. Make : Havells/Wipro/Crompton 284 Supply and fix inreplacement 415V 10KA C curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning MCB TPN40A- 100A 285 Supply and fix only the MCB/RCCB 240V,50Hz,AC with repturing capacity 10kA of the following capacities all as specified and as directed. Make-Havells/Legrand/ABB. 286 MCB SP 6A - 32A 287 RCCB Double pole, 30mA 25 A 288 SPN 32 AMP 289 Maint/ Repair of water supply distribution system repair of pump sets, shallow wells and allied works at 42 WEU at GE (AF) Tvm 290 Excavation in trenches not exc 1.5m wide and not exc 1.5m in depth forlaying UG cable/steel tubing etc and getting out in hard/dense soil complete all as specified and directed. 291 Returning, filling in, including spreading levelling, watering and well ramming in layers not exc 25 cm thick with soil complete all as specified and directed. 292 Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 293 Taking up or down steel tubing and connections of size 25mm dia bore including cleaning for refixing or removal to store complete all as specified and directed.Note: Excavation and earth work shall be measured and paid seperately 294 All as per item No. 293 here in above but of size 50mm dia bore 295 Supply and laying and testing ofmedium grade galvanised iron steel tubing of size 25mm dia bore, ISI marked, including GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tees, checknuts, caps, plugsetc complete laid in trenches/floors etc complete all as specified and directed. Make : Jindal/Tata/Prakash 296 All as per item No. 295 here in above but of size 50mm dia bore 297 Taking up or down UPVC(Unplaticised PVC)pipe and connections of size 25mm dia bore including cleaning for refixing or removal to store complete all as specified and directed.Note :Excavation and earth work shall be measured and paid seperately 298 All as per item No. 297 here in above but of size 50mm dia bore 299 Supply and fix replacement 3-layer UPVC pipes of pressure rating 10 kgf/sqr cm having thermal stabilityincluding all UPVC plain and brass threaded polypropylene random fittings fixed for size 25mm dia bore complete to walls,ceillings or in floorscomplete all as specfied and directed 300 All as per item No. 299 here in above but of size 50mm dia bore 301 S & F in replacement of Gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe of size 25mm diabore and conforming to IS 778 of 1984 complete all as specified and directed.Make : Leader/Kirloskar/Zoloto 302 All as per item No. 301 here in above but of size 50mm dia bore 303 S & F in replacement of gun metal non return valve of 50 mm dia bore, screwed complete all as specified and directed.Make:leader/ Kirloskar/ zoloto 304 S & F in replacement of CIfoot valveBall type flanged end of size 50mm dia bore, flanged/as per IS - 4038 with nuts, bolts and gaskets etc complete all as specified and directed. Make Normax,/Kirloskar/ Leader 305 S & F in replacementofDOL starter suitable for induction motor of current rating 2 to 6 A, 3 Phase 415 Volts, 50 Hz AC complete all as specified and directed.Make: L&T/ siemens/Schineder 306 Dismantling three phase 440 volts motors of 3 HP capacities, cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc and reinstalling in existing position, testing etc complete all as specified and directed. 307 M & L for cleaning Static water tank of 15000 ltr capacity by draining/ pumping out completely , cleaning with high pressure pump and pipe lines for removing scales, algae,silt accumulated at the bottom of the tank, flushing out completely and cleaningthe tank usingchlorine based disinfectans like sodium hypochlorite (liquid beach) or Hydrogen peroxide of not less than 10 KG using high pressure dosing pump and keep it for min 4 hours to the bacteria and painting the wall with food grade synthetic paint and keeping in UV light for minimum of 2 to 3 hrs, writing the date of cleaning and capacity on outside of sump in bold letters etc as per the existing colour and fontcomplete all as specified and directed.
Contract Date: Dec 02, 2025 Contract Value : 27.42 Lakh
Statutory Bodies & Commissions/Committees No of Bidders 5
12.
Railways #8103898 AOC
Supply Of Mig Mag Synergic And Mma Inverter Based Welding Plantmig Mag Synergic And Mma Inverter Based Welding Plant,Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] , Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] , Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] , Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Was-I/Goc, Sr Tamil Nadu 18.00 Numbers Page 1 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly , Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] , Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] , Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Was-I/Goc, Sr Tamil Nadu 18.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G1) Services (Y) Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Was-I/Goc, Sr Tamil Nadu 18.00 Numbers Group G2-Sse/Wbs/Goc 1 763002080015 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Inspection Details Stage Inspection Not Required 2 7630Ns02 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set Inspection Details Stage Inspection Not Required 3 7630Ns03 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set Inspection Details Stage Inspection Not Required 4 7630Ns04 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set Inspection Details Stage Inspection Not Required 5 7630Ser3 Amc (Y) Non Stock --- Yes Consignee Inr (G2) Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Page 2 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 6 7630Ns08 Optional Non Stock --- No Consignee Inr (G2) Spares (Y) Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set 7 7630Ser1 Essential Non Stock --- Yes Consignee Inr (G2) Services (Y) Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G2) Services (Y) Cost Of Preventive Maintenance For 2 Years From The Date Of Commissioning. ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Group G3-Sse/Wcs/Goc 1 763002080015 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers Inspection Details Stage Inspection Not Required 2 7630Ns02 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 3 7630Ns03 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 4 7603Ser3 Amc (Y) Non Stock --- Yes Consignee Inr (G3) Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 5 7630Ns04 Essential Non Stock --- Yes Tpi Agency Inr (G3) Spares (Y) Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 6 7630Ns08 Optional Non Stock --- No Consignee Inr (G3) Spares (Y) Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Page 3 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 7 7630Ser1 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). Page 4 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders 2 Please Refer Clause 0501 To 0504 Of Normal Applicable To Yes Yes Allowed Section I Of Bid Documents Part I Of All Bidders (Mandatory) Document Titled Mig- Mag Synergic And Mma Inverter Based Welding Plant With Air Cooled Torch -500 Amp And Special Conditions For T&P Procurement Bid Document - Part Ii 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 5 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 6 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents Part I & Part Ii And Drawings Enclosed Along With This Tender Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Total All Bidders Value Of The OffEr That Will Be Calculated Based On I. The Cost Of The Basic Welding Plant. Ii. Cost Of The Concomitant Accessories According To Tender Specifications. Iii. Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required. For Making The Welding Plant Fully Functional. Iv. Cost Of Charges Viz. Installation & Commissioning Etc. V. Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. Vi. Cost Of Preventive Maintenance For 2 Years After Commissioning. Vii. Cost Of Camc For 5 Years, Discount At The Rate Of 5% Per Year After 2 Years Of Warranty. Viii. Duties And Taxes As Quoted By The Bidder, Insurance And Freight. It Is Mandatory To Quote For Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi, Though It Will Not Be Taken For Inter-Se Ranking. 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Concomitant All Bidders Accessories/Equipment, Essential Spares, Optional Accessories, Essential Services, Amc Service Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. However, Please Note That Cost Of Optional Spares & Services Shall Not Be Included In The Basic Price Of The Machine For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Concomitant Accessories/Equipment, All Bidders Essential Spares, Optional Accessories,Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? Page 7 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded Annexure A As In Normal Applicable To No No Not Allowed Section Vi, Complete In All Respect? All Bidders 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. Page 8 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) 5 Hsn Code 8515 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 9 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Sse/Wagon Production, Southern Railway, Golden Rock - 620 004, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 10 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 11 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). Page 12 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Milestone Chart Given In Sl .No.7 (Delivery Schedule Chart) Of Technical Speciï¬Cation Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Split Clause: Pre-Decided Quantity Normal Applicable To Yes Yes Not Allowed Splitting Clause Is Applicable As Per The All Bidders Para 5.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document, In Order To Ensure Timely Availability Of Material Through Placement Of Orders On Multiple Sources. 16 Packing Instructions: Use Re-Usable Steel Normal Applicable To Yes Yes Not Allowed Cage (Or) Wooden Box (Or) Gunny Bags All Bidders (Jute Bags) (Or) Carton Box (Or) Polythene Bags>50 Micron Only And Use Railway Parcel Transportation. Please Refer Para 1400 Of Section I Of Bid Document Part I. 17 Option Clause: In Terms Of Railway Board Normal Applicable To Yes Yes Not Allowed Lr. No. 2021/Rs(G)/779/5 Dt. 04/03/22, The All Bidders Purchaser Shall Be Entitled To Vary The Total Order Quantity Upto + 30% Anytime Within The Delivery Period (Including Extended Delivery Period And Even At The Time Of Ordering) By Giving Suitable Notice On The Same Price And Terms And Conditions, Even If The Supply Of Original Ordered Quantity Is Completed Before The Last Date Of Scheduled Delivery. The + 30% Option Clause Can Be Operated In One Or More Than One Instalment As Long As The Total Variation In Quantity Does Not Exceed The Limit Of 30% Of Ordered Quantity. For Operation Of (+) 30% Option Clause, The Increase In Quantity With Respect To The Order Quantity Can Be Done By Giving Suitable Delivery Schedule For The Enhanced Quantity And The Tenderer Shall Be Bound To Accept The Quantity So Ordered On The Basis Of His Original OffEr. In Case Letter Of Acceptance Were Issued For Multiple Consignees With The Same All Inclusive Rate, Then Option Clause Will Be Operated Up To 30% Of The Letter Of Acceptance Quantity For Any Of The Consignee. For Details See Para 2.4 To 2.6 Of Part B - Tender Conditions Of Sr Tender Conditions Attached. Page 13 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 18 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc. All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 14 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 No. Of Stages Of Inspection: One As Per Normal Applicable To No No Not Allowed Quality Assurance Plan In The Bid All Bidders Documents 3 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 4 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 5 Machines Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning, Not From The Date Of Delivery As Mentioned Above In The Schedule Of Requirements. 6 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 7 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 8 Security Deposit Is To Be In Favour Of Dy. Normal Applicable To Yes Yes Not Allowed Fa&Cao/W&S/Goc.Format Can Be Had All Bidders From Annexure 5 In The Document Tender Conditions For Electronic Tenders Uploaded. 9 Evaluation Will Be Group -Wise Normal Applicable To Yes Yes Not Allowed All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances Page 15 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure A And Other All Bidders (Mandatory) Annexures As Required In Bid Documents. Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Documents Attached With Tender S.No. Document Name Document Description 1 5321575.Pdf Irs Conditions 2 5321579.Pdf Southern Railway Conditions For Electronic Tenders 3 5321588.Pdf Tpi Guidelines 4 5325695.Pdf Biddocumentspartii_1.Pdf 5 5325691.Pdf Biddocumentspart1.Pdf 7. Responsiveness S.No. Description I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Traction ( Irene Neethu Singh Densingh ) , Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Was-I/Goc, Sr Tamil Nadu 18.00 Numbers Group G2-Sse/Wbs/Goc 1 763002080015 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Inspection Details Stage Inspection Not Required 2 7630Ns02 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set Inspection Details Stage Inspection Not Required 3 7630Ns03 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set Inspection Details Stage Inspection Not Required 4 7630Ns04 Basic Non Stock --- Yes Tpi Agency Inr (G2) Machine (Y) Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set Inspection Details Stage Inspection Not Required 5 7630Ser3 Amc (Y) Non Stock --- Yes Consignee Inr (G2) Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Page 2 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 6 7630Ns08 Optional Non Stock --- No Consignee Inr (G2) Spares (Y) Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] Consignee Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Set 7 7630Ser1 Essential Non Stock --- Yes Consignee Inr (G2) Services (Y) Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G2) Services (Y) Cost Of Preventive Maintenance For 2 Years From The Date Of Commissioning. ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Group G3-Sse/Wcs/Goc 1 763002080015 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers Inspection Details Stage Inspection Not Required 2 7630Ns02 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 3 7630Ns03 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 4 7603Ser3 Amc (Y) Non Stock --- Yes Consignee Inr (G3) Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 5 7630Ns04 Essential Non Stock --- Yes Tpi Agency Inr (G3) Spares (Y) Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 6 7630Ns08 Optional Non Stock --- No Consignee Inr (G3) Spares (Y) Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Page 3 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 7 7630Ser1 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). Page 4 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders 2 Please Refer Clause 0501 To 0504 Of Normal Applicable To Yes Yes Allowed Section I Of Bid Documents Part I Of All Bidders (Mandatory) Document Titled Mig- Mag Synergic And Mma Inverter Based Welding Plant With Air Cooled Torch -500 Amp And Special Conditions For T&P Procurement Bid Document - Part Ii 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 5 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 6 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents Part I & Part Ii And Drawings Enclosed Along With This Tender Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Total All Bidders Value Of The OffEr That Will Be Calculated Based On I. The Cost Of The Basic Welding Plant. Ii. Cost Of The Concomitant Accessories According To Tender Specifications. Iii. Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required. For Making The Welding Plant Fully Functional. Iv. Cost Of Charges Viz. Installation & Commissioning Etc. V. Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. Vi. Cost Of Preventive Maintenance For 2 Years After Commissioning. Vii. Cost Of Camc For 5 Years, Discount At The Rate Of 5% Per Year After 2 Years Of Warranty. Viii. Duties And Taxes As Quoted By The Bidder, Insurance And Freight. It Is Mandatory To Quote For Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi, Though It Will Not Be Taken For Inter-Se Ranking. 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Concomitant All Bidders Accessories/Equipment, Essential Spares, Optional Accessories, Essential Services, Amc Service Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. However, Please Note That Cost Of Optional Spares & Services Shall Not Be Included In The Basic Price Of The Machine For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Concomitant Accessories/Equipment, All Bidders Essential Spares, Optional Accessories,Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? Page 7 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded Annexure A As In Normal Applicable To No No Not Allowed Section Vi, Complete In All Respect? All Bidders 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. Page 8 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) 5 Hsn Code 8515 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 9 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Sse/Wagon Production, Southern Railway, Golden Rock - 620 004, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 10 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 11 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). Page 12 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Milestone Chart Given In Sl .No.7 (Delivery Schedule Chart) Of Technical Speciï¬Cation Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Split Clause: Pre-Decided Quantity Normal Applicable To Yes Yes Not Allowed Splitting Clause Is Applicable As Per The All Bidders Para 5.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document, In Order To Ensure Timely Availability Of Material Through Placement Of Orders On Multiple Sources. 16 Packing Instructions: Use Re-Usable Steel Normal Applicable To Yes Yes Not Allowed Cage (Or) Wooden Box (Or) Gunny Bags All Bidders (Jute Bags) (Or) Carton Box (Or) Polythene Bags>50 Micron Only And Use Railway Parcel Transportation. Please Refer Para 1400 Of Section I Of Bid Document Part I. 17 Option Clause: In Terms Of Railway Board Normal Applicable To Yes Yes Not Allowed Lr. No. 2021/Rs(G)/779/5 Dt. 04/03/22, The All Bidders Purchaser Shall Be Entitled To Vary The Total Order Quantity Upto + 30% Anytime Within The Delivery Period (Including Extended Delivery Period And Even At The Time Of Ordering) By Giving Suitable Notice On The Same Price And Terms And Conditions, Even If The Supply Of Original Ordered Quantity Is Completed Before The Last Date Of Scheduled Delivery. The + 30% Option Clause Can Be Operated In One Or More Than One Instalment As Long As The Total Variation In Quantity Does Not Exceed The Limit Of 30% Of Ordered Quantity. For Operation Of (+) 30% Option Clause, The Increase In Quantity With Respect To The Order Quantity Can Be Done By Giving Suitable Delivery Schedule For The Enhanced Quantity And The Tenderer Shall Be Bound To Accept The Quantity So Ordered On The Basis Of His Original OffEr. In Case Letter Of Acceptance Were Issued For Multiple Consignees With The Same All Inclusive Rate, Then Option Clause Will Be Operated Up To 30% Of The Letter Of Acceptance Quantity For Any Of The Consignee. For Details See Para 2.4 To 2.6 Of Part B - Tender Conditions Of Sr Tender Conditions Attached. Page 13 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 18 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc. All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 14 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 No. Of Stages Of Inspection: One As Per Normal Applicable To No No Not Allowed Quality Assurance Plan In The Bid All Bidders Documents 3 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 4 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 5 Machines Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning, Not From The Date Of Delivery As Mentioned Above In The Schedule Of Requirements. 6 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 7 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 8 Security Deposit Is To Be In Favour Of Dy. Normal Applicable To Yes Yes Not Allowed Fa&Cao/W&S/Goc.Format Can Be Had All Bidders From Annexure 5 In The Document Tender Conditions For Electronic Tenders Uploaded. 9 Evaluation Will Be Group -Wise Normal Applicable To Yes Yes Not Allowed All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances Page 15 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure A And Other All Bidders (Mandatory) Annexures As Required In Bid Documents. Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Documents Attached With Tender S.No. Document Name Document Description 1 5321575.Pdf Irs Conditions 2 5321579.Pdf Southern Railway Conditions For Electronic Tenders 3 5321588.Pdf Tpi Guidelines 4 5325695.Pdf Biddocumentspartii_1.Pdf 5 5325691.Pdf Biddocumentspart1.Pdf 7. Responsiveness S.No. Description I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Traction ( Irene Neethu Singh Densingh ) , Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] , Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] , Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] , Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] , Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Page 2 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly , Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] , Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G2) Services (Y) Cost Of Preventive Maintenance For 2 Years From The Date Of Commissioning. ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Group G3-Sse/Wcs/Goc 1 763002080015 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers Inspection Details Stage Inspection Not Required 2 7630Ns02 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 3 7630Ns03 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 4 7603Ser3 Amc (Y) Non Stock --- Yes Consignee Inr (G3) Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 5 7630Ns04 Essential Non Stock --- Yes Tpi Agency Inr (G3) Spares (Y) Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 6 7630Ns08 Optional Non Stock --- No Consignee Inr (G3) Spares (Y) Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Page 3 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 7 7630Ser1 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). Page 4 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders 2 Please Refer Clause 0501 To 0504 Of Normal Applicable To Yes Yes Allowed Section I Of Bid Documents Part I Of All Bidders (Mandatory) Document Titled Mig- Mag Synergic And Mma Inverter Based Welding Plant With Air Cooled Torch -500 Amp And Special Conditions For T&P Procurement Bid Document - Part Ii 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 5 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 6 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents Part I & Part Ii And Drawings Enclosed Along With This Tender Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Total All Bidders Value Of The OffEr That Will Be Calculated Based On I. The Cost Of The Basic Welding Plant. Ii. Cost Of The Concomitant Accessories According To Tender Specifications. Iii. Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required. For Making The Welding Plant Fully Functional. Iv. Cost Of Charges Viz. Installation & Commissioning Etc. V. Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. Vi. Cost Of Preventive Maintenance For 2 Years After Commissioning. Vii. Cost Of Camc For 5 Years, Discount At The Rate Of 5% Per Year After 2 Years Of Warranty. Viii. Duties And Taxes As Quoted By The Bidder, Insurance And Freight. It Is Mandatory To Quote For Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi, Though It Will Not Be Taken For Inter-Se Ranking. 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Concomitant All Bidders Accessories/Equipment, Essential Spares, Optional Accessories, Essential Services, Amc Service Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. However, Please Note That Cost Of Optional Spares & Services Shall Not Be Included In The Basic Price Of The Machine For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Concomitant Accessories/Equipment, All Bidders Essential Spares, Optional Accessories,Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? Page 7 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded Annexure A As In Normal Applicable To No No Not Allowed Section Vi, Complete In All Respect? All Bidders 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. Page 8 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) 5 Hsn Code 8515 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 9 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Sse/Wagon Production, Southern Railway, Golden Rock - 620 004, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 10 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 11 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). Page 12 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Milestone Chart Given In Sl .No.7 (Delivery Schedule Chart) Of Technical Speciï¬Cation Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Split Clause: Pre-Decided Quantity Normal Applicable To Yes Yes Not Allowed Splitting Clause Is Applicable As Per The All Bidders Para 5.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document, In Order To Ensure Timely Availability Of Material Through Placement Of Orders On Multiple Sources. 16 Packing Instructions: Use Re-Usable Steel Normal Applicable To Yes Yes Not Allowed Cage (Or) Wooden Box (Or) Gunny Bags All Bidders (Jute Bags) (Or) Carton Box (Or) Polythene Bags>50 Micron Only And Use Railway Parcel Transportation. Please Refer Para 1400 Of Section I Of Bid Document Part I. 17 Option Clause: In Terms Of Railway Board Normal Applicable To Yes Yes Not Allowed Lr. No. 2021/Rs(G)/779/5 Dt. 04/03/22, The All Bidders Purchaser Shall Be Entitled To Vary The Total Order Quantity Upto + 30% Anytime Within The Delivery Period (Including Extended Delivery Period And Even At The Time Of Ordering) By Giving Suitable Notice On The Same Price And Terms And Conditions, Even If The Supply Of Original Ordered Quantity Is Completed Before The Last Date Of Scheduled Delivery. The + 30% Option Clause Can Be Operated In One Or More Than One Instalment As Long As The Total Variation In Quantity Does Not Exceed The Limit Of 30% Of Ordered Quantity. For Operation Of (+) 30% Option Clause, The Increase In Quantity With Respect To The Order Quantity Can Be Done By Giving Suitable Delivery Schedule For The Enhanced Quantity And The Tenderer Shall Be Bound To Accept The Quantity So Ordered On The Basis Of His Original OffEr. In Case Letter Of Acceptance Were Issued For Multiple Consignees With The Same All Inclusive Rate, Then Option Clause Will Be Operated Up To 30% Of The Letter Of Acceptance Quantity For Any Of The Consignee. For Details See Para 2.4 To 2.6 Of Part B - Tender Conditions Of Sr Tender Conditions Attached. Page 13 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 18 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc. All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 14 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 No. Of Stages Of Inspection: One As Per Normal Applicable To No No Not Allowed Quality Assurance Plan In The Bid All Bidders Documents 3 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 4 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 5 Machines Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning, Not From The Date Of Delivery As Mentioned Above In The Schedule Of Requirements. 6 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 7 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 8 Security Deposit Is To Be In Favour Of Dy. Normal Applicable To Yes Yes Not Allowed Fa&Cao/W&S/Goc.Format Can Be Had All Bidders From Annexure 5 In The Document Tender Conditions For Electronic Tenders Uploaded. 9 Evaluation Will Be Group -Wise Normal Applicable To Yes Yes Not Allowed All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances Page 15 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure A And Other All Bidders (Mandatory) Annexures As Required In Bid Documents. Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Documents Attached With Tender S.No. Document Name Document Description 1 5321575.Pdf Irs Conditions 2 5321579.Pdf Southern Railway Conditions For Electronic Tenders 3 5321588.Pdf Tpi Guidelines 4 5325695.Pdf Biddocumentspartii_1.Pdf 5 5325691.Pdf Biddocumentspart1.Pdf 7. Responsiveness S.No. Description I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Traction ( Irene Neethu Singh Densingh ) , Cost Of Preventive Maintenance For 2 Years From The Date Of Commissioning. ] At (Location) Sse/Wbs/Goc, Sr Tamil Nadu 13.00 Numbers Group G3-Sse/Wcs/Goc 1 763002080015 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers Inspection Details Stage Inspection Not Required 2 7630Ns02 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 3 7630Ns03 Basic Non Stock --- Yes Tpi Agency Inr (G3) Machine (Y) Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 4 7603Ser3 Amc (Y) Non Stock --- Yes Consignee Inr (G3) Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 5 7630Ns04 Essential Non Stock --- Yes Tpi Agency Inr (G3) Spares (Y) Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 6 7630Ns08 Optional Non Stock --- No Consignee Inr (G3) Spares (Y) Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Page 3 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 7 7630Ser1 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). Page 4 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders 2 Please Refer Clause 0501 To 0504 Of Normal Applicable To Yes Yes Allowed Section I Of Bid Documents Part I Of All Bidders (Mandatory) Document Titled Mig- Mag Synergic And Mma Inverter Based Welding Plant With Air Cooled Torch -500 Amp And Special Conditions For T&P Procurement Bid Document - Part Ii 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 5 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 6 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents Part I & Part Ii And Drawings Enclosed Along With This Tender Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Total All Bidders Value Of The OffEr That Will Be Calculated Based On I. The Cost Of The Basic Welding Plant. Ii. Cost Of The Concomitant Accessories According To Tender Specifications. Iii. Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required. For Making The Welding Plant Fully Functional. Iv. Cost Of Charges Viz. Installation & Commissioning Etc. V. Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. Vi. Cost Of Preventive Maintenance For 2 Years After Commissioning. Vii. Cost Of Camc For 5 Years, Discount At The Rate Of 5% Per Year After 2 Years Of Warranty. Viii. Duties And Taxes As Quoted By The Bidder, Insurance And Freight. It Is Mandatory To Quote For Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi, Though It Will Not Be Taken For Inter-Se Ranking. 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Concomitant All Bidders Accessories/Equipment, Essential Spares, Optional Accessories, Essential Services, Amc Service Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. However, Please Note That Cost Of Optional Spares & Services Shall Not Be Included In The Basic Price Of The Machine For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Concomitant Accessories/Equipment, All Bidders Essential Spares, Optional Accessories,Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? Page 7 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded Annexure A As In Normal Applicable To No No Not Allowed Section Vi, Complete In All Respect? All Bidders 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. Page 8 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) 5 Hsn Code 8515 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 9 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Sse/Wagon Production, Southern Railway, Golden Rock - 620 004, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 10 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 11 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). Page 12 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Milestone Chart Given In Sl .No.7 (Delivery Schedule Chart) Of Technical Speciï¬Cation Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Split Clause: Pre-Decided Quantity Normal Applicable To Yes Yes Not Allowed Splitting Clause Is Applicable As Per The All Bidders Para 5.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document, In Order To Ensure Timely Availability Of Material Through Placement Of Orders On Multiple Sources. 16 Packing Instructions: Use Re-Usable Steel Normal Applicable To Yes Yes Not Allowed Cage (Or) Wooden Box (Or) Gunny Bags All Bidders (Jute Bags) (Or) Carton Box (Or) Polythene Bags>50 Micron Only And Use Railway Parcel Transportation. Please Refer Para 1400 Of Section I Of Bid Document Part I. 17 Option Clause: In Terms Of Railway Board Normal Applicable To Yes Yes Not Allowed Lr. No. 2021/Rs(G)/779/5 Dt. 04/03/22, The All Bidders Purchaser Shall Be Entitled To Vary The Total Order Quantity Upto + 30% Anytime Within The Delivery Period (Including Extended Delivery Period And Even At The Time Of Ordering) By Giving Suitable Notice On The Same Price And Terms And Conditions, Even If The Supply Of Original Ordered Quantity Is Completed Before The Last Date Of Scheduled Delivery. The + 30% Option Clause Can Be Operated In One Or More Than One Instalment As Long As The Total Variation In Quantity Does Not Exceed The Limit Of 30% Of Ordered Quantity. For Operation Of (+) 30% Option Clause, The Increase In Quantity With Respect To The Order Quantity Can Be Done By Giving Suitable Delivery Schedule For The Enhanced Quantity And The Tenderer Shall Be Bound To Accept The Quantity So Ordered On The Basis Of His Original OffEr. In Case Letter Of Acceptance Were Issued For Multiple Consignees With The Same All Inclusive Rate, Then Option Clause Will Be Operated Up To 30% Of The Letter Of Acceptance Quantity For Any Of The Consignee. For Details See Para 2.4 To 2.6 Of Part B - Tender Conditions Of Sr Tender Conditions Attached. Page 13 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 18 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc. All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 14 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 No. Of Stages Of Inspection: One As Per Normal Applicable To No No Not Allowed Quality Assurance Plan In The Bid All Bidders Documents 3 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 4 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 5 Machines Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning, Not From The Date Of Delivery As Mentioned Above In The Schedule Of Requirements. 6 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 7 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 8 Security Deposit Is To Be In Favour Of Dy. Normal Applicable To Yes Yes Not Allowed Fa&Cao/W&S/Goc.Format Can Be Had All Bidders From Annexure 5 In The Document Tender Conditions For Electronic Tenders Uploaded. 9 Evaluation Will Be Group -Wise Normal Applicable To Yes Yes Not Allowed All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances Page 15 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure A And Other All Bidders (Mandatory) Annexures As Required In Bid Documents. Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Documents Attached With Tender S.No. Document Name Document Description 1 5321575.Pdf Irs Conditions 2 5321579.Pdf Southern Railway Conditions For Electronic Tenders 3 5321588.Pdf Tpi Guidelines 4 5325695.Pdf Biddocumentspartii_1.Pdf 5 5325691.Pdf Biddocumentspart1.Pdf 7. Responsiveness S.No. Description I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Traction ( Irene Neethu Singh Densingh ) , Supply Of Mig- Mag Synergic And Mma Inverter Based Welding Plant As Per Parameters Speci Fied In Schedule -I (Of Section V Of Bd Part Ii) Conforming To Specifications Given In Bid Documents Part Ii. [ Warranty Period: 24 Months After The Date Of Delivery ] ] , Cost Of The Concomitant Accessories As Per Schedule I Of Bid Document Part Ii. ] , Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required For Making The Welding Plant Fully Functional. ] , Amc For 5 Years After Completion Of 2 Years Of Warranty Period. [ Warranty Period: 2 Years, Amc Period: 5 Years, Rate Of Discounting: 10 % ] ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 5 7630Ns04 Essential Non Stock --- Yes Tpi Agency Inr (G3) Spares (Y) Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Inspection Details Stage Inspection Not Required 6 7630Ns08 Optional Non Stock --- No Consignee Inr (G3) Spares (Y) Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] Consignee Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Set Page 3 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 7 7630Ser1 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). Page 4 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4. Eligibility Conditions Special Eligibility Criteria S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Supply To Be Strictly As Per Speciï¬Cations Normal Applicable To Yes Yes Not Allowed Document Uploaded With This Tender. All Bidders 2 Please Refer Clause 0501 To 0504 Of Normal Applicable To Yes Yes Allowed Section I Of Bid Documents Part I Of All Bidders (Mandatory) Document Titled Mig- Mag Synergic And Mma Inverter Based Welding Plant With Air Cooled Torch -500 Amp And Special Conditions For T&P Procurement Bid Document - Part Ii 3 Preferably Manufacturers Should Normal Applicable To Yes Yes Allowed Participate. Participating Traders/Agents All Bidders (Optional) Must Attach Authorization Letter Issued By The Oem Or Oem Authorized Stockiest Along With Their OffEr. Authorization Letter Should Preferably Be Tender Speciï¬C. In Case Of General Authorization Letter, It Must Clearly Indicate The Validity Period/Expiry Date. OffErs With General Authorization Letter Silent On Validity Period/Expiry Date Will Not Be Considered For Placement Of Order And That OffEr Is Liable To Be Ignored. (Please Refer Para 3.4 Of Part B Of Sr Tender Conditions). 4 Procurement Of The Item Is Restricted To Normal Applicable To Yes Yes Not Allowed Local Suppliers With Minimum Local All Bidders Content Of 20% (Class-I Or Class-Ii Local Supplier As Deï¬Ned In Railway Board Letter No.2020/Rs(G)/779/2/Pt.1 Dated 25.09.2020 With Latest Amendments, If Any) Only And The Vendors Who Do Not Qualify To Be Local Suppliers (I.E.), Non- Local Suppliers With Local Content Less Than 20%) Should Not Quote In The Tender As Their OffErs Shall Not Be Considered For Any Ordering. In Case Any Vendor Who Does Not Qualify To Be A Local Supplier For The Tendered Item Participates In The Tender, It Does So At Its Own Risk And Cost And Railways Shall Not Be Liable For Any Loss Or Damage Caused To The Vendor. OffEr Of The ϬRm Shall Be Summarily Rejected In Case Of Non-Compliance Of Above Declaration. For More Details, The Tenderer Shall Refer Para 16.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document. Page 5 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 5 Earnest Money Deposit (Emd) Shall Be Normal Applicable To Yes Yes Not Allowed Deposited By All Vendors For Tenders With All Bidders Estimated Value Above Rs.25 Lakhs Subject To The Applicable Exemptions. The Para 2.1 Of The Part A Of Sr Tender Conditions With Regard To Emd Exemption Is Superseded As Below And The Conditions Mentioned Here Below Will Prevail Over That Of In Para 2.1 Of The Part A Of Sr Tender Conditions Attached To This Tender Document: Emd Amount Shall Be Mentioned In All Tenders Irrespective Of The Nature Of Tender As Per The Emd Amount Mentioned In Clause 2.3 Of Part A Of Sr Tender Conditions Or As Decided By The Purchaser Under The Policy. There Shall Be No Exemption From Submission Of Emd For Any Tender Or By Any Tenderer Subject To Provisions Under Clause 10.4.3 Of Part A Of Sr Tender Conditions Except Following : (I) Emd Shall Normally Not Be Called Against Tenders With Estimated Value Up To Rs.25 Lakhs (Including Single Tenders, Global Limited Tenders) Except Cases Where Competent Authority Incorporates The Condition To Call For Emd. Ii) Public Sector Undertakings (Psus) A. Psus Owned By Ministry Of Railways And B. Psus For The Group Of Items That Are Manufactured By Them. Iii) Mses Registered Under Udyam Registration Shall Be Eligible For Exemption From Payment Of Emd Irrespective Of Relevance Of Product Category For Which They Are Registered With Udyam. However, Traders/Distributors/Sole Agent/Works Contract Are Not Exempted From Payment Of Emd As They Are Excluded From The Purview Of The Policy. Iv) Other Railways, Indian Ordinance Factories And Govt. Departments. V) In Exceptional Cases, Where Emd Exemption Is Speciï¬Cally Incorporated In Tender Conditions. Vi) Vendors Registered With Southern Railway For The Trade Group/Trade Groups Of The Tendered Item . Vii) Regular And Development Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/ Core Etc., For Those Speciï¬C Item For Which They Are On The Approved List, Subject To Approval Status Being Valid On The Date Of Tender Closing. Viii) Vendors Registered With Railways For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Emd For These Items. Ix) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Emd. Kvic And Acash Shall Be Exempted From Emd For Items Supplied By Them. In Case Of Submission Of Earnest Money Deposit In The Form Of Bank Guarantee, Please Refer Annexure- 6 Of Sr Tender Conditions For The Proforma For Bg. Page 6 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 6 All The Tenderers Shall Have To Submit Normal Applicable To Yes Yes Allowed Clause-Wise Compliance Of Speciï¬Cation All Bidders (Mandatory) Mentioned In Bid Documents Part I & Part Ii And Drawings Enclosed Along With This Tender Or Product Catalogue For The Make And Model OffEred Should Be Submitted By The Tenderer, Spelling Out Deviations, If Any, To Ascertain Technical Suitability. An OffEr, Whose Technical Suitability Cannot Be Ascertained, May Be Liable To Be Ignored. 7 Inter - Se Position Of Offers Would Normal Applicable To Yes Yes Not Allowed Be Determined Based On The Total All Bidders Value Of The OffEr That Will Be Calculated Based On I. The Cost Of The Basic Welding Plant. Ii. Cost Of The Concomitant Accessories According To Tender Specifications. Iii. Cost Of Any Other Accessory Which In The Opinion Of Supplier Is Essentially Required. For Making The Welding Plant Fully Functional. Iv. Cost Of Charges Viz. Installation & Commissioning Etc. V. Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. Vi. Cost Of Preventive Maintenance For 2 Years After Commissioning. Vii. Cost Of Camc For 5 Years, Discount At The Rate Of 5% Per Year After 2 Years Of Warranty. Viii. Duties And Taxes As Quoted By The Bidder, Insurance And Freight. It Is Mandatory To Quote For Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi, Though It Will Not Be Taken For Inter-Se Ranking. 8 Firms Have To Quote Cost Of Basic Normal Applicable To Yes Yes Not Allowed Machine, Concomitant All Bidders Accessories/Equipment, Essential Spares, Optional Accessories, Essential Services, Amc Service Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. However, Please Note That Cost Of Optional Spares & Services Shall Not Be Included In The Basic Price Of The Machine For Inter-Se Ranking. 5. Compliance Conditions Check List S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Have You Quoted Cost Of Basic Machine, Normal Applicable To No No Not Allowed Concomitant Accessories/Equipment, All Bidders Essential Spares, Optional Accessories,Essential Services, Amc Service, Training Etc. It Is Mandatory To Submit OffErs Against All These Items, Otherwise OffEr Will Not Be Considered For Inter-Se Ranking. 2 Have You Attached Documents To Prove Normal Applicable To No No Not Allowed Your Eligibility And Past Performance As All Bidders Per Tender Requirement? Page 7 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 3 Have You Attached Certiï¬Cation Of Local Normal Applicable To No No Not Allowed Content From Statutory Auditor/ Cost All Bidders Accountant? 4 Have You Quoted Warranty Oblications As Normal Applicable To No No Not Allowed Per Tender Requirement? All Bidders 5 Have You Quoted Delivery Period Correctly Normal Applicable To No No Not Allowed And Precisely? All Bidders 6 Have You Uploaded Annexure A As In Normal Applicable To No No Not Allowed Section Vi, Complete In All Respect? All Bidders 7 Have You Submitted All Supporting Normal Applicable To No No Not Allowed Documents Required? All Bidders 8 Have You Read The Security Deposit (Sd) Normal Applicable To No No Not Allowed Condition At Para 10 Of Part A Of Sr All Bidders Tender Conditions Attached With This Tender Document And Uploaded Relevant Document For Seeking Exemption From Submission Of Sd? If Not, Are You Ready To Pay Security Deposit? 9 Are You Coming Under Mse Status Given Normal Applicable To No No Not Allowed As Per Guidelines Issued By Railway Board All Bidders For Purchase Preference Vide Letter No. 2010-Rs [G] -363-1 Dt. 05.07.2012 Or Latest. If Yes,Have You Attached Valid Documents (Udyam Registration Certificate) Towards Being Mse? 10 Have You Furnished The Statement Of Normal Applicable To No No Not Allowed Deviations?[Preferably Nil] All Bidders 11 Have You Quoted The Discount If Any In The Normal Applicable To No No Not Allowed Specified Column Only In Ireps? All Bidders 12 Have You Furnished Bank Account Details Normal Applicable To No No Not Allowed Such As Name Of The Bank And Address, All Bidders Account No., Micr, Ifsc Code And Type Of Account To Facilitate Eft Payment? 13 Please Check Our Website Before Normal Applicable To No No Not Allowed Submitting OffEr, Whether Any All Bidders Corrigendum To The Tender Has Been Issued Or Not. 14 Firm To Indicate Make-Model-Brand Normal Applicable To No No Not Allowed Offered, If Any. All Bidders 15 Have You Kept Your OffEr Valid For 120 Normal Applicable To No No Not Allowed Days? All Bidders Commercial-Compliance S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 In Case Of Road Delivery, The Date Of Normal Applicable To Yes Yes Not Allowed Delivery At Destination [Consignees End] All Bidders Shall Only Be Treated As Delivery Date Irrespective Of F.O.R. / F.O.T. Condition Mentioned Elsewhere In The Contract / Tender. 2 Tenderers May Note That Their OffEred Normal Applicable To Yes Yes Not Allowed Delivery Schedule Should Clearly Indicate All Bidders The Starting Time, Quarterly Rate Of Supply And ϬNishing Time. For OffErs With Vague Delivery Schedule Like -02 To 12 Months- Or Like -06 To 10 Months-, Delivery Period Shall Be Given As Per The Requirement Best Suited To This Oï¬Ƒce Within The Quoted Range. 3 The Bidder Conï¬Rms That Rates And Other Normal Applicable To Yes Yes Not Allowed ϬNancial Terms Quoted In Relevant All Bidders Columns Of ϬNancial Bid Will Only Be Ruling Terms For Acceptance, And Such Terms Quoted Anywhere Else Should Be Ignored. Page 8 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 4 Whenever Tender Is Ϭ‚Oated With Purchase Normal Applicable To Yes Yes Not Allowed Restriction From Sources Approved By All Bidders Nominated Authorities And There Exists A Suspected Cartel Situation By Approved Sources Or The Rates Available From Approved Source/Sources Are Adjudged Unreasonably High, Despite Fair EffOrts As Permissible, The Purchaser Reserves The Right To Place Orders On ϬRm(S) Outside The Approved Vendor List, Without Any Restrictions.(Please Refer Para 4.0 Of Part B Of Sr Tender Conditions Document Attached To This Tender Document For Further Details.) 5 Hsn Code 8515 Normal Applicable To Yes Yes Not Allowed [A] All The Bidders/Tenderers Should Ensure All Bidders That They Are Gst Compliant And Their Quoted Tax Structure/Rates Are As Per The Gst Law. Firms Must Indicate Its Gst Registration Number Along With Their Offer. [B] In Case The Successful Tenderer Is Not Liable To Be Registered Under Cgst/Igst /Utgst/Sgst Act, The Railway Shall Deduct The Applicable Gst From His/Their Bills Under Reverse Charge Mechanism (Rcm) And Deposit The Same To The Concerned Tax Authority. [C] The ϬRm Should Indicate The Tariff Code (Hsn Code) For Claiming Gst For The Tendered Item. [D] The OffEr Shall Be Evaluated Based On The Gst Rate As Quoted By Each Bidder And Same Will Be Used For Determining The Inter-Se Ranking. While Submitting OffEr, It Shall Be The Responsibility Of The Bidder To Ensure That They Quote Correct Gst Rate And Hsn Number. [E] It Shall Be The Responsibility Of The Bidders To Quote Correct Hsn Number And Corresponding Gst Rate. The Purchaser Shall Not Be Responsible For Any Misclassiï¬Cation Of Hsn Number Or Incorrect Gst Rate, If Quoted By The Bidder. [F] Wherever, The Successful Bidder Invoices The Goods At Gst Rate Or Hsn Number Which Is DiffErent From That Incorporated In The Purchase Order, Payment Shall Be Made As Per Gst Rate Which Is Lower Of The Gst Rate Incorporated In The Purchase Order Or Billed. [G] Vendor Is Informed That She/He Would Be Required To Adjust Her/His Basic Price To The Extent Required By Higher Tax Bill As Per Invoice To Match The All Inclusive Price As Mentioned In The Purchase Order. [H] Any Amendment To Gst Rate Or Hsn Number In The Contract Shall Be As Per The Contractual Conditions And Statutory Amendments In The Quoted Gst Rate And Hsn Number, Under Svc. 6 Please Refer Para 15.0 Of Part - B Of Sr Normal Applicable To Yes Yes Not Allowed Tender Conditions Attached With This All Bidders Tender Document For Details Regarding Benefits Of Mse As Per Public Procurement Policy. 7 For Public Procurement (Preference To Normal Applicable To Yes Yes Not Allowed Make In India) Policy, Please Refer Para All Bidders 16.0 Of Part- B Of Sr Tender Conditions Attached To This Tender Document. Page 9 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 8 Bidder Shall Accept The Following Normal Applicable To Yes Yes Allowed Declaration [Land Border Condition] By All Bidders (Mandatory) Quoting Yes Against Conf. Allowed Or Complied Column For Compliance Of Oï¬Ƒce Memorandum Of Department Of Expenditure, Ministry Of Finance Om No. F.No.6/18/2019-Ppd Dated 23.07.2020. If Such Certiï¬Cate Given By A Bidder Whose Bid Is Accepted Is Found To Be False, This Would Be A Ground For Immediate Termination And Further Legal Action In Accordance With Law. I/We Have Read The Clause Regarding Restrictions On Procurement From A Bidder Of A Country Which Shares A Land Border With India. I/We Certify That This Bidder Is Not From Such A Country Or , If From Such A Country, Has Been Registered With The Competent Authority. I/We Hereby Certify That This Bidder, Fulfills All Requirements In This Regard, And Is Eligible To Be Considered. (Where Applicable, Evidence Of Valid Registration By The Competent Authority Shall Be Attached.) 9 1) Bidders Are Instructed Not To Indulge In Normal Applicable To Yes Yes Not Allowed Any Anti-Competitive Practices. As Per The All Bidders Provisions Of Competition Act,2002, Railways Can Make A Reference To The Competition Commission Of India For Making An Enquiry In Case Of Suspected Anti-Competitive Behavior By The Bidders. 2) Collusive Bidding, Bid Rotation, Bid Suppression, Complementary Bidding, Market Allocation And Sub-Contracting Arrangements Fall Under The Purview Of Bid Rigging Which Would Cause Appreciable Adverse EffEct On Competition. 3) Competition Commission Of India Can Impose Heavy Penalties Such As: Penalty Upto 10% Of The Average Turnover For The Last Three Preceding ϬNancial Years Upon Each Of Such Enterprises Which Are Parties To Bid-Rigging And Can Even Order The Parties To Cease And Desist. 10 A) For : Destination. By Road. Normal Applicable To Yes Yes Not Allowed Accordingly, The ϬRms Are Advised To All Bidders Quote On For Destination Basis By Road And Offers With Deviations Are Liable To Be Ignored. B) Door Delivery Shall Be Made To The Consignees Along With Delivery Challan Postal Address Of The Consignees Is: Sse/Wagon Production, Southern Railway, Golden Rock - 620 004, Tamil Nadu, India. Southern Railway Gst No. 33Aaagm0289c1zq. Page 10 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 11 Failure Consequences: In Case The ϬRm Normal Applicable To Yes Yes Not Allowed Fails To Execute The Contract Within The All Bidders Original Delivery Period, The Purchaser Will Be Entitled To Impose Liquidated Damages For Extension Of Delivery Period. For Any Reason, If The Supplier Fails To Supply Goods And/Or Service As Per The Conditions Of Contract, As Amended From Time To Time, Purchaser Shall Have The Right To Levy Damages From The Supplier For Failing To Comply With The Contractual Conditions, Not By The Way Of Penalty, An Amount Equal To Security Deposit Of The Defaulted Order Amount. These Damages Shall Be Treated As Recoveries Outstanding Against The Vendor And Dealt With Accordingly. 12 Tenderers To Acknowledge Having Read Normal Applicable To Yes Yes Not Allowed And Also Accept The Irs Conditions Of All Bidders Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/Attached To This Tender Document. Page 11 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 13 Security Deposit Shall Be Taken From All Normal Applicable To Yes Yes Not Allowed Vendors For Contract Value Above Rs.25 All Bidders Lakhs. Security Deposit Is 5% Of Total Value Of Contract Subject To Max Rs. 50 Lakhs For Contract Value Above 25 Lakhs And Up To Rs.50 Crore. Subject To The Applicable Exemptions. Security Deposit From Successful Tenderers Should Be Received In Purchase Oï¬Ƒce Within 21 Days From The Date Of Communication Of Acceptance With Respect To The Purchaser. There Shall Be No Exemption From Submission Of Security Deposit For Any Tender Or By Any Tenderer Except Following: A) The Store Contract Cases Of Value Upto Rs.25 (Twenty Five) Lakh, B) Other Railways And Government Departments In Terms Of Railway Boards Letter No. 2004/Rs(G)/779/11 Dated 24.07.2007 C) Indian Ordinance Factories In Terms Of Railway Boards Letter No.92/Rss(G)/363/1 Dated 08.04.1993 D) Psus Owned By Ministry Of Railways And Psus For The Group Of Items That Are Manufactured By Them In Terms Of Railway Boards Letter No.2003/Rs(G)/779/5 Dated 10.09.2004 E) In Tenders Issued Against Pac, Oem In Whose Favour Pac Has Been Issued Shall Be Exempted From Submitting Sd. Kvic And Acash Shall Be Exempted From Sd For Items Supplied By Them. F) Vendors Registered With Railways For The Trade Group Of The Item Tendered Shall Be Exempted From Sd For Orders Valued Up To Their Monetary Limit Of Registration. G) Vendors Appearing On The Approved Vendor Lists Of Rdso/Pus/Core Subject To Approval Status Being Valid On The Date Of Tender Closing H) Vendors Registered With Railway For Supply Of Medicine, Medical Equipments And Consumables Shall Be Exempted From Submission Of Sd For These Items. (Please Refer Para 10.0 Of Part A Of Sr Tender Conditions Enclosed To This Tender Document For Further Details On This Clause). Page 12 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 14 (A) Free Delivery To Consignee. Supply Of Normal Applicable To Yes Yes Not Allowed Machine Shall Be Made As Per The All Bidders Milestone Chart Given In Sl .No.7 (Delivery Schedule Chart) Of Technical Speciï¬Cation Enclosed. (B) Bill Payment: After Successful Completion Of Purchase Order, ϬRm Has To Submit The Bill On-Line Through Ireps Portal Only For Payment. In This Regard, The Following Documents Have To Be Uploaded Based On The Crn (R-Note) Issued By Railway (A) Invoice, Gst Declaration( I.E. Self Declaration Regarding Aggregate Annual Turnover In A ϬNancial Year: Less (Or) More Than 50 Crores / Less(Or) More Than 100 Crores/Less (Or) More Than 500 Crores. If More Than 500 Crores, E-Invoice Is Required To Be Uploaded.), Rnote, Neft Mandatory. (B) Warranty/Guarantee Certiï¬Cate, Rites Certiï¬Cate, Test Report, Dealership Certiï¬Cate (Or) Proof Of Purchase From Authorized Dealer, Calibration Certiï¬Cate, Commissioning Report Whichever Is Applicable. 15 Split Clause: Pre-Decided Quantity Normal Applicable To Yes Yes Not Allowed Splitting Clause Is Applicable As Per The All Bidders Para 5.0 Of Part B Of Sr Tender Conditions Attached To This Tender Document, In Order To Ensure Timely Availability Of Material Through Placement Of Orders On Multiple Sources. 16 Packing Instructions: Use Re-Usable Steel Normal Applicable To Yes Yes Not Allowed Cage (Or) Wooden Box (Or) Gunny Bags All Bidders (Jute Bags) (Or) Carton Box (Or) Polythene Bags>50 Micron Only And Use Railway Parcel Transportation. Please Refer Para 1400 Of Section I Of Bid Document Part I. 17 Option Clause: In Terms Of Railway Board Normal Applicable To Yes Yes Not Allowed Lr. No. 2021/Rs(G)/779/5 Dt. 04/03/22, The All Bidders Purchaser Shall Be Entitled To Vary The Total Order Quantity Upto + 30% Anytime Within The Delivery Period (Including Extended Delivery Period And Even At The Time Of Ordering) By Giving Suitable Notice On The Same Price And Terms And Conditions, Even If The Supply Of Original Ordered Quantity Is Completed Before The Last Date Of Scheduled Delivery. The + 30% Option Clause Can Be Operated In One Or More Than One Instalment As Long As The Total Variation In Quantity Does Not Exceed The Limit Of 30% Of Ordered Quantity. For Operation Of (+) 30% Option Clause, The Increase In Quantity With Respect To The Order Quantity Can Be Done By Giving Suitable Delivery Schedule For The Enhanced Quantity And The Tenderer Shall Be Bound To Accept The Quantity So Ordered On The Basis Of His Original OffEr. In Case Letter Of Acceptance Were Issued For Multiple Consignees With The Same All Inclusive Rate, Then Option Clause Will Be Operated Up To 30% Of The Letter Of Acceptance Quantity For Any Of The Consignee. For Details See Para 2.4 To 2.6 Of Part B - Tender Conditions Of Sr Tender Conditions Attached. Page 13 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 18 Please Enter The Percentage Of Local Normal Applicable To No Yes Allowed Content In The Material Being OffEred. All Bidders (Optional) Please Enter 0 For Fully Imported Items, And 100 For Fully Indigenous Items. The Deï¬Nition And Calculation Of Local Content Shall Be In Accordance With The Make In India Policy As Incorporated In The Tender Conditions. General Instructions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Railway Is Not Bound To Accept The Lowest Normal Applicable To No No Not Allowed Or Any Tender Or To Assign Any Reason For All Bidders Doing So And Railway Reserves The Right To Accept/Cancel Any Tender In Respect Of The Whole Or Any Portion Of The Items Specified In The Schedule Annexed (Or Tender Schedule) And The Contractor Shall Be Required To Supply The Same At The Rate Quoted. 2 1. For Any Queries Against This Tender, Normal Applicable To No No Not Allowed Please Contact Cmm/M/Sr At 9003060762. All Bidders 2. Any Technical Clariï¬Cation Regarding Drawing/Speciï¬Cation Can Be Obtained From The Oï¬Ƒce Of The Pcme/Sr/Mas. Dy.Cme/Planning/Mas Mobile No. 9003060403 And Mail Id [email protected]. Drawing (S) / Speciï¬Cation (S) Can Also Be Obtained From The Above Oï¬Ƒce After Payment Requisite Cost. 3 Vendors May Please Note That Giving Normal Applicable To No No Not Allowed Intimation Regarding The Tender In Open All Bidders Tender Cases Or Giving Limited Tender Enquiry Does Not Guarantee The Suitability Of OffEr For Placement Of Purchase Order. Railway Reserve The Right To Place Purchase Order Subject To Fulï¬Lment Of Technical/Commercial Eligibility Conditions/Tender Conditions. 4 All Other Terms & Conditions As Per Irs Normal Applicable To No No Not Allowed Condition And Gcc. All Bidders Other Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading Page 14 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 1 A) Inspection By Tpi (Third Party Normal Applicable To No No Not Allowed Inspection Agency). Firm To Indicate All Bidders Complete Works Address Where Inspection Will Be Conducted. The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions For Further Details Regarding Tpi Clause. Please Note That OffErs With Inspection/Visual Inspection By Tpi Against Test Certiï¬Cate/Guarantee Certiï¬Cate /Work Test Certiï¬Cate Is Liable To Be Ignored. For Further Details Regarding Tpi Clause, The Tenderer Shall Refer Annexure 13 Of Sr Tender Conditions Attached To This Tender Document. Alternatively, Tenderers May Please Refer The Attachment Tpi Conditions Enclosed To This Tender Document For Ready Reference Of Bidders Regarding Tpi Clause. B) Bidder Shall Indicate Place Of Inspection For Pre-Dispatch Inspection Duly Enclosing The Documentary Evidence. Note:- Any Request For Change In Place Of Inspection Shall Only Be Entertained With Documentary Evidence. 2 No. Of Stages Of Inspection: One As Per Normal Applicable To No No Not Allowed Quality Assurance Plan In The Bid All Bidders Documents 3 Marking : Manufacturer To Mark His Normal Applicable To Yes Yes Not Allowed Name And Date Of Manufacture As Per All Bidders Drawing, Wherever Indicated, Or At A Location Where It May Not Get Obliterated In Service On The Item Being Supplied By Them Against The Purchase Order. Supplies Received Without This Are Liable To Be Rejected By Consignee. 4 I/We Agree To Supply The Tendered Stores Normal Applicable To Yes Yes Not Allowed At The Rates Quoted By Me/Us In All Bidders Accordance With The Irs Conditions Of Contract, Sr Tender Conditions, Special And Other Conditions Speciï¬Ed In This Tender Document/ Attached With This Tender Document. 5 Machines Should Have Warranty Of 24 Normal Applicable To Yes Yes Not Allowed Months From Date Of Successful All Bidders Commissioning, Not From The Date Of Delivery As Mentioned Above In The Schedule Of Requirements. 6 No Developmental Order Will Be Placed For Normal Applicable To Yes Yes Not Allowed The Tendered Item. All Bidders 7 Post Warranty Camc Will Be Concluded By Normal Applicable To Yes Yes Not Allowed End-User Consignee At Their End After All Bidders Warranty Period, If Required. 8 Security Deposit Is To Be In Favour Of Dy. Normal Applicable To Yes Yes Not Allowed Fa&Cao/W&S/Goc.Format Can Be Had All Bidders From Annexure 5 In The Document Tender Conditions For Electronic Tenders Uploaded. 9 Evaluation Will Be Group -Wise Normal Applicable To Yes Yes Not Allowed All Bidders Special Conditions S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Insurance Charges Should Be Quoted In Normal Applicable To No No Not Allowed Other Charges Column Against The All Bidders Particular Items. No Separate Line Has Been Provided For Insurance Charges. Technical-Compliances Page 15 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly Tender Document Tender No 16255002 Closing Date/Time 25/04/2025 14:30 S.No. Description Template Condition Confirmation Remarks Documents Applicability Required Allowed Uploading 1 Bidders Must Submit Their Technical Bids Normal Applicable To Yes Yes Allowed As Per Format Annexure A And Other All Bidders (Mandatory) Annexures As Required In Bid Documents. Tenderers Are Required To Submit Complete Details Including Values, Write- Up, Drawings, Sketch, Brochure Etc. As Per Requirement Speciï¬Ed In Respective Clauses Mentioned Therein. In Case Of Incomplete / Sketchy Information, The Technical OffEr Being Incomplete Is Liable To Be Rejected. Tenderers Should Clearly Indicate Compliance. 6. Documents Attached With Tender S.No. Document Name Document Description 1 5321575.Pdf Irs Conditions 2 5321579.Pdf Southern Railway Conditions For Electronic Tenders 3 5321588.Pdf Tpi Guidelines 4 5325695.Pdf Biddocumentspartii_1.Pdf 5 5325691.Pdf Biddocumentspart1.Pdf 7. Responsiveness S.No. Description I/We Have Carefully Gone Through The Irs Conditions Of Contract (Included And Uploaded Along With The Bid Document) Particularly Para 2500 Pertaining To Code Of Integrity, Misdemeanor And Penalties. I/We Hereby Certify That No Other Sister Concerns Or Aï¬Ƒliates (Such As Having Common Partner/Director/Promoter/Owner/Holding Company Decision Control Etc.) Have Participated In This Tender Which Can Give Rise To A ConflIct Of Interest Or Fall Under Anti-Competitive Practices. We Understand That The 1 OffErs Of All Such Sister Concerns Including Ours Are Liable To Be Rejected As Per Relevant Provisions Of Irs Terms And Conditions. I/We, Aï¬Ƒrm That We Shall Abide By The Code Of Integrity In General, With Speciï¬C Reference To ConflIct Of Interest [Para 2502 (E)], Anti Competitive Practices [Para 2502(C)] And Obligation To Proactive Disclosures [Para 2503]. I/We Understand That We Are Fully Responsible For The Above Declaration And It Shall Not Be The Railways Responsibility To Verify The Same. I/We Are Aware That We Shall Be Liable For All Consequences Of Violation Of Code Of Integrity, If Detected, At Any Stage. 2 Validity Of Offer:-120 Days, No Deviation From The Offer Validity Period Stipulated In The Tender Is Permitted. The Tenderers In Their Bid Shall Indicate The Details Of Their Gst Jurisdictional Assessing Officers (Designation, Address & Email Id). In Case Of A Contract Award, A Copy Of Purchase Order Shall Be Immediately Forwarded By Purchaser To The Gst Jurisdictional Assessing Officer Mentioned In Tenderers Bid This Tender Complies With Public Procurement Policy (Make In India) Order 2017, Dated 15/06/2017, Issued By Department Of Industrial Promotion And Policy, Ministry Of Commerce, Circulated Vide Railway Board Letter No. 2015/Rs(G)/779/5 Dated 03/08/2017 And 27/12/2017 And Amendments/ Revisions Thereof. As A Tender Inviting Authority, The Undersigned Has Ensured That The Issue Of This Tender Does Not Violate Provisions Of Gfr Regarding Procurement Through Gem. Digitally Signed By Dy.Cmm/Traction ( Irene Neethu Singh Densingh ) , Consumables As Per Clause 4 Of Section V With Breakup Of Individual Items As Applicable. ] , Spares And Service Charges Post Warranty Period In The Format Vide Annexure K In Section Vi . ] , Cost Of Charges Viz. Installation & Commissioning Etc. Of Mig- Mag Synergic And Mma Inverte R Based Welding Plant As Per Parameters Specified In Schedule -I (Of Section V Of Bd Part Ii) Conforming To S Pecifications Given In Bid Documents Part Ii. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 8 7630Ser2 Essential Non Stock --- Yes Consignee Inr (G3) Services (Y) Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers 3. T And C F.O.R Description Destination Delivery Period Description Delivery /Completion Rate Of Supply For All Items Commencement : Within 2 Months Of Issue Of Contract, However, Delivery Completion : Within 3 Months Thereafter Period Shall Not Exceed No. Of Days As Mentioned In Delivery Schedule Chart Of Para 7 Of Section Iv Of Bid Document Part Ii. However, The Delivery Period Indicated Being Tentative, May Vary At The The Time Of Placement Of Order. Payment Terms S.No Description Payment Terms 1 1) 60% Payment: Upon Receipt Of The M&P (Includes Covered Shed, Linkage Of Track, Inside Shed, Outside Shed, Power Supply Connection, Provision Of Toilets With Urinal Facility Along With Septic Tanks), Duly Pre- Inspected By A Third -Party Inspection (Tpi) Agency, Receipted At The Site By The Consignee In Good Condition And Submission Of A Joint Receipt Note. 2) 20% Intermediate Payment: After Successful Installation And Commissioning And Submission Of A Joint Commissioning Note. 3) Final 20% Payment: After Commissioning Of The M&P At The Consignees End For A Minimum Period Of 30 Days, Upon Submission Of A 10% Warranty Bank Guarantee And A Proving Test Certificate Statutory Variation Clause S.No Description 1 Statutory Variation In Taxes And Duties, Or Fresh Imposition Of Taxes And Duties By State/ Central Governments In Respect Of The Items Stipulated In The Contract (And Not The Raw Materials Thereof), Within The Original Delivery Period Stipulated In The Contract, Or Last Unconditionally Extended Delivery Period Shall Be To Railways Account. Only Such Variation Shall Be Admissible Which Takes Place After The Submission Of Bid. No Claim On Account Of Statutory Variation In Respect Of Existing Tax/Duty Will Be Accepted Unless The Tenderer Has Clearly Indicated In His OffEr The Rate Of Tax/Duty Considered In His Quoted Rate. No Claim On Account Of Statutory Variation Shall Be Admissible On Account Of Misclassiï¬Cation By The Supplier/ Contractor. Standard Governing Conditions S.No Description 1 The Bidder Agrees To Supply The Tendered Stores At The Rates Quoted By Him In Accordance With The Latest Version Of Irs Conditions Of Contract (Attached As Irs Conditions Of Contract To This Tender Document For Ready Reference) And Southern Railway Tender Conditions (Attached As Sr Tender Conditions To This Tender Document For Ready Reference). Page 4 Of 16 Run Date/Time: 04/04/2025 13:26:19Stores/Southern Rly , Cost Of Preventive Maintenance For 2 Years After Commissioning. ] At (Location) Sse/Wcs/Goc, Sr Tamil Nadu 9.00 Numbers
Contract Date: Oct 13, 2025 Contract Value : 94.40 Lakh
Government Departments No of Bidders 1
13.
Health and Family Welfare #7987142 AOC
Tender For One Time Repairing And There After Comprehensive Annual Maintenance Camc Of Split Type Air Conditioning Machines Installed At Basirhat Super Speciality Hospital, District North 24 Pgs(2Nd Call).- 1 Comprehensive Annual Maintenance Contract (CAMC) 2 Comprehensive Annual Maintenance Contract (CAMC) of Carrier (Midea) make 2 Tr. Split AC Machine installed at Different location of Basirhat Super Speciality Hospital, District: North 24 PGS. as per terms and conditions mentioned bellow:During the AMC period, the selected will inspect and carryout the preventive maintenance of the Split type HVAC system at Basirhat SSH, with 4(four) times per year in equal gapping period as per following details:i) Compulsory cleaning the condenser coils, evaporator coil, fins, filters and drain trays by jet water spray machine and cleaning of parts of Split AC units with air blower in each quarter throughout the year.ii) Checking the refrigeration system including copper pipeline with checking of refrigerant gas pressure and rectify the system with refrigerant gas top up/refill, if any abnormality seen without any additional cost within time frame of 48(forty eight) hours from the complaint lodged. iii) The agency will check compressors, Fan & Motors, blower, P.C.B., Switches, Transformers, All types of coils, internal Electrical items etc. to ensure the proper functioning and if any defect is found, the same will be repaired without any additional cost within time frame of 48(forty eight) hours from the complaint lodged.B. If WBMSCL wish to shift any machine to another location within the premises of Basirhat SSH, the same may done through the contractor. The cost of such shifting work will be borne by WBMSCL.C. The contract will be for a one years. Further renewal of Contract will be mutually discussed and agreed upon. The contract may be terminated by either side with a notice of 3(three) months.D. The agency should have to submit service report for each machine and maintenance log book.E. All types of filters will be checked and cleaned during preventive maintenance service. In case of replacement of filter the cost will be borne by WBMSCL.F. If the contractor fails and found reluctant to attend the breakdown maintenance services in due time as already mentioned in clause no-1-b and 1-C a penalty amount will be imposed for such incompliance of the breakdown issue @ Rs. 500/- per day, maximum to 10% of the contract value of respective AC unit. G. The will have to arrange for own manpower for electrical -mechanical & plumbing work, tools and tackles, ladder/scrap holding,transportation, accommodation, fooding etc. WBMSCL will provide power supply and Water only.H. Force Majeure:If at any time during the contract period the performance by either party under this Order cannot be performed by reasons of any declared war, hostility, acts of the public or enemy, civil commotion, sabotage, fire, flood, earthquake, explosion, epidemic, quarantine, restrictions or other acts of God, (hereinafter referred to as eventuality) affecting the supply or installation & commissioning or respective obligation of the Parties, the affected party shall notify the other of the happening of any such eventuality . In such an event neither party shall be entitled to terminate this Order, nor shall either party have any claim for damages against the other in respect of such non-performance of the work under this Order. The performance shall be resumed as soon as practicable after such eventuality has come to an end or ceased to exist. Under such circumstances the contractual delivery or completion period shall be extended by a period equal to that during which such eventuality operated plus an additional period, if any, as may be considered reasonable by WBMSCL and Contractor. 3 One time repairing beforeCAMC (Breakdown restoration work) 4 Thoroughly servicing & overhauling of 2.0 TR AC including cleaning the condenser coils, evaporator coil, fins, filters and drain trays by jet water spray machine and cleaning of parts of Split AC units with air blower 5 STIC of new PCB (2 nos. outdoor and 1 no. indoor) for 2 TR split AC (inverter type), including dismantle and handed over the existing old damaged PCB to the Hospital authority 6 SITC of new rotary type compressor of Midea make, Model no :- MSC124EL4W3 machine including dismantle and handed over the existing old damaged compressor to the Hospital authority 7 Leak testing by Nitrogen gas, Leak repairing by CU brazing method and vacuuming the unit properly using vacuum pump and their after charging refrigerant gas in 2 Tr. Split type AC machine. 8 Supply & Charging of refrigerant gas ( R-410A) 9 Supply & Fixing of 19 mm thick nytryl rubber insulation and rapping with nitryl tape on existing Cu. Pipe Indoor to Outdoor including all 10 Supply & Fixing of new 60 mfd capacitor for 2 Tr. Split type AC machine. Make:- Tibcon or Similar any reputed Brand approved by EIC 11 Supply & Delivery 72mmx20m waterproof aluminium foil adhesive tape
Contract Date: Sep 19, 2025 Contract Value : 91,786
Government Departments No of Bidders 2
West Bengal View Result →
14.
Defence #7636241 AOC
Tender For Provision Of Cgsd (Kochi) At Willingdon Island, Kochi; 1 SCHEDULE A Part - I (BUILDING & STRUCTURE WORKS)Details of prepriced schedule is given in tender documents. 2 SCHEDULE A PART-II ( SITE CLEARENCE/DEVELOPMENT & EARTH WORKS) Details of prepriced Schedule is given in tender documents. 3 SCHEDULE A PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 4 SCHEDULE A PART-IV (INTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 5 SCHEDULE A PART-V (FIRE FIGHTING)Details of prepriced Schedule is given in tender documents. 6 SCHEDULE A PART-VI (ROAD/PATH/ HARD STANDING/CULVERT)Details of prepriced Schedule is given in tender documents. 7 SCHEDULE A PART-VII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents. 8 SCHEDULE A PART-VIII (EXTERNAL ELECTRIFICATION) Details of prepriced Schedule is given in tender documents. 9 SCHEDULE A PART-IX (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents. 10 SCHEDULE A PART-X (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents. 11 SCHEDULE A PART-XI (COMPOUND WALL) Details of prepriced Schedule is given in tender documents. 12 SCHEDULE A PART-XII (ORGANIC WASTE CONVERTER AND SMART ENERGY METER) Details of prepriced Schedule is given in tender documents. 13 SCHEDULE A PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as Rs 0.00 under Col. E signifies this fact only. 14 INTERNAL WATER SUPPLY S & F for 15 mm dia bore CP two way bib cock with CP wall flange (Make : Jaquar Model No. OPP15041PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 15 S & F for 15 mm dia bore CP bib cock with CP wall flange (Make : Jaquar Model No. OPP15037PM / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 16 S & F for 20 mm bore concealed Stop cock reqular brass body with spindle extnwith Exposed Part Kit of Concealed Stop Cock with Fitting Sleeve, Operating Lever & Adjustable Wall Flange (Compatible with ALD-083CQT & ALD-089CQT)(Make : Jaquar Model No. ALD 089 CQT/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch , screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 17 S & F for 25 mm dia bore concealed Stop cock reqular brass body with spindle extn with Flush Cock & Wall Flange 25mm Ceramic Disc Cartridge) with Plain Knob (Make : Jaquar Model No. ALD 081/ Eqvlt in Kohler/Grohe), cast copper alloy, screwed down high pressure with crutch, screwed both ends for CPVC pipes or for union and fixed complete all as specified and directed by Engr-in-charge. 18 S & F 20mm bore CP angular stop cock with CP wall flange (Make : Jaquar Model No. CQT 23053 / Eqvlt in Kohler/Grohe), cast copper alloy, screwed down, high pressure with crutch, screwed both ends for iron pipe or for union and fixed 19 S & F for 100 mm overhead shower rose round shape single flow (ABS Body chrome plated with gray face plate (Make : Jaquar Model No. 1989 with SHA 479L300S / Eqvlt in Kohler/ ESS ESS) with Shower Arm ø20mm & 300mm Long Round Shape with 90˚ Bend for Wall Mounted Showers with Stainless Steel connected to pipe complete all as specified and directed by Engr-in-charge. 20 COOLING APPLIANCESDesign, Supply, Installation, Testing and Commissioning of Invertor Type Floor Mounted Packaged AC Units of specified capacities, combination of energy efficient Inverter compressor plus fixed compressors, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include Group controller also asrequired for controlling AC from a single point and timer option for load sharing of AC units complete all as specified and as directed by Engineer - in - charge, of following capacities.Note: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. (HIGH SIDE (MACHINES))(Outdoor unit) 21 a) 22 TR Inverter Package AC Units 22 b) 16.5 TR Inverter Package AC Unit 23 Design, Supply, Installation, Testing and Commissioning of Normal Type Floor Mounted Packaged AC Units of specified capacities, nominal capacity condensing unit with all standard fittings, safety devices, like HP/LP cutout, single phase preventor, overload relays, R-410A Gas, vibration isolation pads etc. Suitable to work till 50 Deg ambient, Blue Fin Condensor and Corrosion Resistant Body, Wide Voltage Range 360V - 440V, The quoted rate shall include support works for outdoor units with necessary catwalk for service access complete all as specified and as directed by Engineer - in - charge, of following capacitiesNote: Design report shall be submitted before execution of work at site by the contractor to GE for his scruitiny/comments and further submitted to AO for his approval.Make: Blue Star/Daikin/Haeir/Godrej/Voltas/Equivalent. LOW SIDE (MACHINES))(Indoor unit) 24 a) 22 TR Inverter Package AC Units 25 b) 16.5 TR Inverter Package AC Unit 26 Supply, Installation and Testing of Refrigerant pipingwith necessary clamping (suction & Discharge) Hard/Soft drawn Copper tube of suitable sizes, with copper elbows, tees, Tubular Nitrile Insulations etc as required complete all as specified and as directed by Engineer - in - charge. 27 S & F Control Cabling B/W Indoor & Outdoor units 28 M & L Refrigerant Gas - R410A 29 Supply, Installation and Testing of Hard PVC drain piping. Drain piping with Tubular Nitrile Rubber Insulation: complete in all respects, well clamped till drain Points complete all as specified and as directed by Engineer - in - charge. For All Units 30 DUCTINGSupply, fabrication, installation, testing of GI rectangular ducts, complete with all fittings such as tee, bends, special off shoots, inspection doors, transformation pieces etc. as required as per IS 655 including suspension and supporting arrangement for plenum, duct etc. required complete all as specified and as directed by Engineer - in - charge. 31 a) Using 0.63 mm (24 Gauge) GI sheet 32 b) Using 0.80 mm (22 Gauge) GI sheet 33 c) Using 1.00 mm (20 Gauge) GI sheet 34 DUCT INSULATION & LININGSupply and Installation of Acoustic Insulation of ducts using 9MM Open Cell Nitrile Rubber, well adhesived, 150 - 180 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 35 Supply, installation & testing of Thermal Insulation of ducts using 9MM Closed Cell Nitrile Rubber, well adhesived, 40-60 Kg/cm2 complete all as specified and as directed by Engineer - in - charge. 36 S & F Canvas Connection 37 AIR DISTRIBUTION PRODUCTSSupply and Fixing of Powder Coated Aluminium Grills/ Diffusers (Supply/ Return) complete all as specified and as directed by Engineer - in - charge. 38 S & F Collar Dampers 39 Supply and Installation of Fire Dampers complete all as specified and as directed by Engineer - in - charge. 40 Supply, Installation, Testing and Commissioning of Heater Bank Plus Humidistat Arrangement complete all as specified and as directed by Engineer - in - charge. 41 Supply and fixing, testing and commissioning water coolerhaving stainless steel body with inbuild purifier HIMA 7 NHC, dispencing capacity 125 ltr/hr and storage tank capacity 40 ltr normal and 40 cold electric driven (single phase), 230 volt, AC power supply with all connecting accessories complete all as specified and directed. 42 Supply and fixrefrigerator, electric driven (single phase), 220 V,50 HZ, capacity 195 Litres, 3 Star rated direct cool inverter, single door all as specified and directed by the Engineer-in-Charge. 43 Supply and install, testing and commissioning of split type air conditioner 1.5 TR Capacity of invertertechnology 5 star rating with cordless remote control single phase 240 volts complete with all accessories such as indoor and outdoor units and refrigerent tubing of adequete length as required at site indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables, etc and making good the disturbed surface by matching with existing adjoining surface complete all as specified and directed (Cooling appliances- qty 4, Air conditioning- qty 10) 44 Supply and fix Voltage stabilizer 3 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% 45 Supply and fix Voltage stabilizer 4 KVA for automatic operation, single phase naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 280 V with output voltage stabilized at 230 V with accuracy of ± 2.5% (Cooling appliances-qty4, Air conditioning- qty 10) 46 AIR CONDITIONINGSupply and install,Testing & commissioning of split type air conditioner 2 TR capacity of inverter technology 5 star ratingwith cordless remote control, single phase 240 volts complete with all accessories such asindoor and outdoor units and refrigerent tubing of adequete length as required at site, indoor mounting plate, duly powder coated fixing with anchor bolts at any height, drain pipe of suitable size brought to ground level from any height, initial filling of refrigerent gas including making round hole on existing wall for taking up refrigerent tubing, drain pipe, cables etc and making good the surace by matching with adjoining surface complete all as specified and directed. 47 Supply and fix Voltage stabilizer 5 KVA for automatic operation,single phase naturally air cooled indoor type, Wall mounted type & designed for input variation between 170 V to 280 V with output voltage stabilized at230 V with accuracy of ± 2.5% 48 INTERNAL ELECTRIFICATIONS & F LED Mirror light 1 x 5W LUMOS ECCO 1 feet Make: Luker or Equivalent 49 S & F modular MCB DBOx 3 Pin Socket with MCB SP 20 Amp, 240 V including plastic enclosure as per manufacturer instruction fixed on wall surface complete for Air conditioner all as specified and as directed. (Make:-Havells, Model-DHDMCSN0251016 or equivalent) 50 Supply and fix Air circulator of 600 mm sweep AC single Phase. 230V, 1440 RPM complete all as specified and as directed. (Make: Havells model, Turbo Force Wall or equivalent) 51 S & FVertical triple pole & neutral (VTPN), double door, 16-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 52 S & FVertical triple pole & neutral (VTPN), double door, 4-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for FPMCCB as incomer and TPN/SP MCBs as outgoing, reversible metal door, 200 A copper busbar for each phase, fully insulated & shrouded neutral bar, earth bar, wiriest & cable ties for cable management, profited masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed. 53 M & L for Flame ProofMCB Distribution board SPN 12 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB -10 Nos as outgoingcomplete all as specified and as directed. 54 M & L for Flame ProofMCB Distribution board SPN 8 way, with case iron body, powder painted, with 200 Amps rated bus bar etc. including provision of one 32 Amps SPN MCB as incoming and 6 Amps SP MCB- 6 Nos as outgoingcomplete all as specified and as directed. 55 Supply and fix Engage light with Green & Red LED complete all as specified and as directed 56 Supply and fix of CS mounted high intensity LED search light, long range, manually swivel in all direction, 250 W, minimum range 700 meters, Single, LED Efficiency> 140 lm/w, PF> 0.95, CCT 5500K - 6500K, Optical grade PMMA/PC lens/reflector efficiency>95%, multiple circuit to avoid complete run down, anti UV, narrow beam 5 degree, die cast LM6 body with air fins, powder coated, constant current, an average lux at 10 meter - 8000 lux with circle of approx 600 mm, working temp: -20 to +60 degree C, input Volt 100-300 VAC, 50 Hz, PF >0.95, IP-66, confirming to LM79/ LM80 and type tested as per IS: 10322/ IS: 13383, BIS approved and Govt lab tested for lux intensity. The search light is completed with manual revolving CS stand D20cm x H15cm (min.) with 3 nos. foundation holes for mounting of searchlight on watchtower structure, manual rotation of light on horizontally 360 degree with 45 degree tiltable with provision of both instant locking arrangement at desired position. Model No. CS-LRFLL-25PC25 of KALIN make or equivalent 57 Supply, install, testing and commisisong of outdoor floor/wall mounted thermoplastic polycarbonatefeeder pillar panel, Enystar EmptyEnclosures, IP-65, weatherproof, corrosion free, Halogen and Silicon Free, Frame retardant with Opaque Lid Size-[276 x 546 x 186]mm and Transparent Hinged Lid, completed all as specified and directed. 58 M & L for TV socket module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 59 M & L for telephone jack with module metal flushed including flushed Box cover plate Box for 2 way module complete all as specified. 60 Supply and lay coaxial cable for TV Cabledrawn through conduit 61 S & F flame proof exhaust fan 300 mm sweep, single phase, 1440 RPM complete all as specified and as directed. 62 FIRE FIGHTINGSupply and fix Foot Valve conforming to IS 4038, 100 mmdia. 63 Supply and fix Foot Valve conforming to IS 4038, 150 mmdia. 64 Supply and fix Cast Iron Air Valves with single air Outlets, conforming to IS 14845 of size 100 mm dia bore and fixing up in Cast Iron Water supply mains of size 100 mm dia. 65 S & F sprinkler flexible drop pipe 1 mtr long. 66 S & F sprinkler rossette 25 mm dia. 67 Supply and installation, testing and commissioning of Analog Addressable type Active Loop Repeater (Loop power/external power) Fire terminal with inbuit turbo isolator, Backlit LCD Display 6x40 characters display, having Controls For Reset, Mute, Accept, Silence alarms and Self Test, with programmable free keys and Duly Approved byEN54/LPCB/VDS/FM Make: SIEMENS/NOTIFIER/BOSCH 68 M & L for Low smoke Zero helogen flame retardent fire alarm cable2 core, 1.5 mm² copper conductor confirming to BS7629-I, BS6387 & rated for 500 v grade having plaine sraded copper coductutor with priming insulation of glass mica fire resistance tape & secondery insulation of high performancesilicon rubber with electrostatic screen of aluminium fire barrier Type LT53 outer sheath confirming to BS 7655, red in colour drawn through & including concealed steel conduit including laying,fixing,connecting complete all as specified and directed. 69 Staircase signage down of make bajaj cat part no. 111499 model no. DSDWBB 3W double side display for staircase downwards (with 2 hours built in battery backup) complete all as specified and directed at site complete all as specified and directed. 70 S & F wall mounted LED emergency Exit signage luminaire Lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up upto 05 hours(Cat No. 220211 Make Bajaj or equivalent to CG/Havells. 71 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, indoor type, LT panel board , made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and comprising of the following:- Make of MCCB/MCB -MDS/LEGRAND/L&T/HEGGER (Main Fire Fighting Panel)INCOMING(i) MCCB 4 Pole 160 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release - 01 No.(ii) Voltmeter Digital type 0-500 Volts range flush type with selector switch- 01 No(iii) Aluminium Bus bar TPN - 200 amps- 1setOUTGOING(i) MCCB 3 Pole 125 amp 50 Hz, 415 V with reputing capacity 35 KA with microprocessor based release- 01 No.(iii) MCB TPN 32 Amp -02 Nos(iv) 80 HP S/D STARTER- 01 Nos(v) DOL STARTER 7.5 HP- 01 Nos(vi) Motor Protection Relay32-88 amps- 1 no. (vii) Motor Protection Relay2-5.5 amps- 1 no. (viii) On/Off/Trip Indication Lamps, 220 V AC- 6 nos.(ix) Start/Stop Push Button, 2 No. (x) Phase indicating lamps RYB for incoming and each outgoing connection.(xi) Digital type Ammeter 0- 150 amps with selector switch and CT coils of suitable capacity for incoming and each outgoing connection- 1 no. 72 M & L for coating and wrapping of under ground steel pipe buried in soil shall have protection against corrosion as per IS-10221.The coating and wrapping shall be carried out in systamatic manner to get uniform thickness of coating as per IS specification 73 Supply, Installation, test and Commissioning CPRI APPROVED factoryfabricated, Indoor type, LT panel board, made out of 2 mm thick CRCA Sheetsingle door withboth side opening including Neoprene Rubber Gasket, suitable for 440 Volt 3 Phase 4 Wire System, including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate complete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeddedwith 50X50X6mm Mild Steel Angle Iron Frame and 750 mm above the Normal Ground Level complete withinternal connection with suitable size of cable, cable lugs and cable glandsPCC Foundation in Cement Concrete 1:3:6 (20 mm Graded Stone Aggregate) and Testing after Installation includingcomplete all as specified and & directedby Engr-in-charge comprising of the following :– ( Booster terrace pump panel)INCOMING:-(a) INCOMING MCCB 40 A 25 KA, 4 POLE- 01 No.(b) Busbar TPN of size 100 apms - 1 setOUTGOINGS:-(a) MCB 3 POLE TPN 32 Amps,10 KA-2 Nos.(b)DOL Starter for 7.5 HP Pump set-1 Nos.(c) Ammeter Class-1, digital panel mounting type 96mmx96mm L & T cat no WDS301FCA00 including CT 50X5 Amps 3 nos & selector switch-4 nos(d) Voltmeter Class- 1, digital panel mounting type 96mmx96mm L&T CAT NO.WDS301FEV00 & selector switch - 1 no.(e) LED TYPE indicator lamp 1 set (set of three for R,Y,B)(f) Mini protecrionRelay 4-11 amp - 1 nos. 74 Fire Extinguisher mechanical Foam type trolly mouted of 9 Liters capacity. Ceasefire 9 litrs fire Extinguisher AFFF Foam type, External Cartridge type, Pressure Guage Gross weight 14.6 Kg, empty weight5.6 Kg, Can height 611 MM, Diameter 175 MM, Discharge time less than 60 Secs controllable discharge mechanism, Minimum 6 Mtrs, Applicable on Class A, B, can construction deep down & CO2 Mig welded Valve Construction: Forging & Machining, Internal coating of can: Epoxy powder coating, External coating of can: Epoxy poyster powder coating sheet metal thickness 2.0MM,1 year warranty. Make Cease Fire Or Equivalent. (pol store) 75 Supply, Installation,Testing & commissioning of Carbon Dioxide (Co2) type fire extinguisher of 4.5 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 76 Supply, Installation,Testing & commissioning ofDRY CHEMICAL POWDER (ABC) stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 77 Supply, Installation,Testing & commissioning of Water Mist High pressure stored pressure type fire extinguisher of 9 Kg confirm to IS: 15683, with ISI marked/TAC approved fitted with required accessories including wall suspension brackets. 78 Supply and installation at approved location approved make Fire sand bucket of 24 gauge galvanized steel sheet, each set shall have 4 buckets with stand & Showel etc, complete. 79 SPECIAL EQUIPMENTS FOR STORESDesign, manufacture, Supply, installation, testing and commissioning of Automated Storage and Retrieval System with storage racks, pallets, stacking crane, computer hardware with compatible inventory software as a turnkey solution complete all as specified and directed. Automated Storage and Retrieval System shall consist of computer controlled & PLC stacker crane driven system for automatically placing & retrieving materials from defined storage locations. The crane shall be capable of lifiting, stacking and retriveing the pallet loads weight upto 1125 Kg (max) complete all as specified and directed by the Engineer-in-Charge. Technical data for design of heavy duty ASRS:-(a) Dimensions:-Height:10 Mtrs for racking system which shall be designed and constructed to store the required no. and size of pallets.(b)Storage capacity:-Pallet Size: 1300 (W) x 1200(D) x 1250 (H) in mmPallet Nos.: 480Pallet load capacity: 1125 KgTotal capacity: 540 Tons(c) Stacker Crane: Single mast automated stacker crane for handling Pallet, size 1300mm(W) x 1200mm (D) x 1250mm (H) and pay load (including Pallet self weight) of 1125 Kg max. The stacker crane shall be capable of picking up the pallet from in-feed conveyor or loading station and stacking it into empty slots of racking system. Similarly, it shall also be capable of retrieving the palltet from racking system and putting it on the same conveyor or unloading station. Stacker crane will be mounted on single rail at the bottom to traverse the length of the storage system. A single top rail mounted on the racking system shall also support it.General technical parameters of stacker crane:Technical parameters/Type- Single Mast(i) Operation mode (Networking)- On-line automatic / Single automatic (Ground/Boarding) /Manual operation (Boarding) / Maintenance (ii) Communication Means- Wireless 80 (iii) Power supply mode- 380 to 415 V, 50 Hz, three phase five wire (iv) Addressing mode- Horizontal and verticle operation: photo electrical sensor + bar code scanners(v) Positioning / Reduction accuracy (mm) level- lifting ± 3 - 5, Fork : ± 3(vi) Fork unit- 1 Double deep fork(vii) Load unit- MS Pallet (viii) Total Height- 10 Mtr(ix) The normal lifting speed (m/min) - 10 MPM(x) The normal running speed (m/min) - 65 MPM(xi) Rated load- 1125 Kg(xii) Receipt equipment fixed platform/conveyor/lifting /platform(electric/manual)- Conveyor(d) Pallets: to stack and retrieve the pallet weighing up to loaded pallet weight 1125 Kg at height up to the last loading level in the racking system. It should have retrieval mechanism to enable stacking & retrieval of pallet from either side of the rack and also to pick up the load directly from the loading station.Pallet Details:-(i) Dimensions - 1300mm(W) x 1200mm(D)(ii) Pallet height- 1250 mm(e) Racking system :- Two aisle having two row racking system each with 05 verticle levels for storage of material. Racking for double deep type storage of 480 Pallet of size 1300mm(W) x 1200mm (D) x 1250mm (H). Loaded pallet weight: Pay load with pallet 1125 Kg max. System details:-Working aisle -01 Nos. (Double deep)Store rack -24 Nos./RowTotal rack in 1 aisle-24 (Left) + 24 (Right)= 48 Nos.No. of level- 5 Nos/RackTotal Pallet-48 x 5 x 2 = 480 Nos.Load capacity- 1125 Kg/LevelSingle mast stacker crane-01 No. 81 (f)Aisle Equipment:-This will consist of electrical as well mechanical aisle equipments and willl be designed as per the pallet requirement. The mechanical Aisle equipment of bottom rail shall consist of I Beam and will be provided with adjustable calmps for holding the rail in position to ensure proper alignment. Top rail shall be mounted on the racking. The electrical aisle equipment shall consist of power rail (fully enclosed bus bar having 7 pole system), which is mounted on the racking system below the first loading level.(g) Details of rack members:-The racking system shall consist of cold-rolled steel sections as per manufacturers design to accommodate and store pallets and connected systems.(h) Loading- unloading station/ Conveyor(i) Pallet Load 1125 Kg max.(ii) Bearing- SKF Equivalent make(iii) Motor- Seimens/Sew Euro Drive/Nord Sew/ Bonfiglioli or equivalent(iv) Gear Box- Bonfiglioli Make or equivalent(v) V.F.D.- Yashkawa make or equivalent(j) All steel surface shall be powder coated finish with 8 tank treatment process.(k) Maintenence: The annual maintenence of complete ASRS system duyring the defect liability period of two years shall be included in the rate quoted for the system and the AMC contract duly signed with the manufacturer of the ASRS system shall be submitted at the time of handling over the system. The AMC shall include all spares and consumables etc required during the period of two years and nothing extra shall be paid on this accountNote- 1Mechanical safety provision (i) End of aisle shock absorbers / bumpers for stacker crane.(ii) End of travel buffer for the lifting crane.(iii) Safety catches on lifting carriage.(iv) Anti-tilt mechanism for the stacker crane.(v) Continuous rail cleaning brush for floor rail.(vi) Adjustable rail clamp to ensure alignment. 82 (vii) Resilient rubber pads on adjustable clamps for vibration dampening.(viii) Profile check on lifting carriage to check all three dimensions (width, depth & height) of the pallet. Note - 2 Electrical safety provision (i) There shall be Emergency stop push button at all panels and stations.(ii) Optical light beam amd mechanical safety sensor to stop the operation in case of improper storage or obstruction in the operator window either internal or external reasons like operator hand or material placed at edge of the tray.(iii) Back up circuitry for proper system operation.(iv) An electromagnetic brake shall be used to avoid the slippage of the hoist.(v) Stopper shall be provided for the maintenance door.(vi) Load cells shall be provided for the over weight of tray.(vii) Automatic door shall be provided for operator safety while machine in operating condition.Note - 3 Physical safety provision (i) The ASRS system shall comprise of safety fences having grid size of max. 40 x 40mm & wire dia should be of min. 3 mm. Height of the fencing should be minimum 2.0 meter.(ii) One No. of electromagnetic aisle access door shall be provided. It should cover the complete length of the system on one side.(iii) A manual locking system to restrict the movement of unauthorised personnel shall be provided.NOTE: Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. Item No. 13.070 below shall be compatible with this item/ system and both should be integratedMake of ASR system:Armstrong Ltd/ Godrej Koerber/ Kardex India storage solutions Pvt Ltd/ Daifuku India Pvt Ltd/ Addverb technologies Ltd/ Craftsman Automation Ltd/ Tech-mark 83 Supply, installation, testing and commissioning of Advance Inventory Management System with computer hardware with compatible inventory software complete all as specified and directed by the Engineer-in-Charge. Technical specification of the system(i) System Height : 6400 (±100) mm(ii) System Width : 3150 (±100) mm(iii) System Depth : 2300 (±100) mm(iv) System Base : 7.24 Sq.Mtr(v) Tray Int. Size: 300 (H) x 2450(W) x 500 (D) in mm(vi) Tray dead weight - 57 Kg (Approx.)(vii) Per tray weight capacity - 300 KgTechnical specification of the system:-(viii) Tray Quantity : 32 Nos.(ix) Usable net load - 9.6 ton(x) Storage surface area per system - 39.2 sq mtr(xi) Door - Automatic(xii) Power consumption - 3.7 KW(xiii) Power supply - 440V, 50/60 Hz, 3 Phase(xiv) Motor 3 Phase 1440 RPM - Seimens make or equivalent(xv) Chain - Diamond makeor equivalent(xvi) Bearing - SKF/NTN make or equivalent(xvii) External cladding - Epoxy powder coatedSafety Features:1. Photo curtain at access port, 2. Motor Protection relays, 3. Limit switch at door, 4. Single phase preventer,5. Switch mode power supply, 6. 15 Min battery backup for PLC, 7. Noise less than 60db, 8. Emergency stop various safety alertsNote: The system and software provided under this item shall be of same make as for item 13.069 or a compatible system and software as recommended by the chosen manufacturer of ASR system. This system shall be integrated with ASR system. 84 Supply, installation and testing of Car Traffic Boom Barrier 6 mtr suitable to working on power supply 230 Volt, 50 Hz, 24V DC electric motor, adjustable with CAMS, operating ambient temperature from -20 to +55 Degree Celsius, uses cycle 2000/Day, air cooling, type of beam is rectangular with skirt, effective torque 280-290 Nm open/close time 2 to 4 Sec complete all as specified and as directed by Engineer-in- charge.Make: FAAC/Parkilo/Skidata/BFT 85 EXTERNAL WATER SUPPLYSupply and fix Foot valve conforming to IS,100 mm dia complete all as specified and directed. 86 Supply and fix Cast iron air release valve with 100 mm bore and two outlets as per IS:14845 complete all as specified and directed. 87 Supply, installing, testing and commissioning of electrically driven horizontal Centrifugal Pump set 9.0 LPS at 50 Meter Head as per specification, motor TEFC type, 2880 rpm, 415 V, 50 Hz, 3 phase, class F insulation, IP 55 protection, starting on suitable Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller (as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation, bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 550 LPM at 45 mtr head inclusive of suitable rated three phase starter as recommended by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.(01 No. Working + 01 No Stand By)Make:- Kirloskar Brothers/Crompton or equivalent. 88 Supply, install, test and commissioning of LT Panel, indoor type, powder coated, 2.0 mm thick CRCA Sheet, CPRI approved having, IP 43, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply, bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2.0 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: LT Panel for Pump House. The LT Panel comprising of the following:- 89 Incoming:-MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, breaking capacity 36 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 01 sets(b) Digital Multi function meter - 01 No.(c) CTs - 100/5A, CL-1, 15 VA - 01 set(d) Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 350 Amps for phase and 350 amp for the neutral barOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 16 KA- 02 No. Ics =100% Icu -2 nos.(b) MCB, TPN 40 Amp, 415 Volt, C Curve - 02 Nos.(c) Star Delta starter 12.5 HP, 3 Phase, 415 Volt- 02 Nos.(d ) Digital ammeter - 2nos.(e) Single Phase Preventer - 2 nos. 90 M & L Valve chamber of internal size 0.90m X 0.90m X 0.90m (internal dimensions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation, brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to internal surfaces and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos. of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The quoted rate shall include all earthwork and connected items. 91 M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No. 3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessary test on completion all as specified and as directed. 92 EXTERNAL ELECTRIFICATIONM & L for HT/LT MS cable route indicator, engraved the description on the disc not less than 6 dia welded with 40x6xmm MS strip of approx length 90 cm duly painted on the steel parts as per colour code and provision of PCC 1:4:8 type D-2 using 40 mm grade stone aggregate of not less than 0.05 cum in each at base under the ground including necessary earth work and formwork complete all as specified and directed.Note: HT route indicator shall be painted as under:-(i) For HT 11 KV cables - “BROWN”(ii) For LT cables - “BLUE” 93 Supply and fix compact air insulated bus bar trunking system with copper busbar 1600 Amps, 50 KA breaking capacity, IP54 protection, bus duct 1600 A, 415 Volt, capacity sandwich type, Set RYBN complete with accessories such as flange ends, vertical bends, supporting brackets etc from transformer to LT panel board complete all as specified and directed. 94 Supply, install, testing and commissioning of Distribution transformer step-down Level 2 (Previously EE Level 3 before Amendment No 4 to IS 1180), 11KV0.433KV, Three Phase complying withIS: 1180/IEC-76(Part-1) 2014 with latest amendments, indoortype double copper wound suitable for 50 Hz system of capacity 800 KVA, oil immersed naturally cooled delta connected on HT side and Star connected on LT side, Vector Group Dyn11, provided with OFF load tap changer to vary secondary voltage from -7.5% to + 7.5 % in step of 2.5 %.Losses should be confined to the limits specified as follows: maximum allowable losses atfull load (100 %) & Half Load (50 %) shall not be exceeded 5838 watts & 2147 Wattsrespectively as per GRlHA RATING, Percentage Impedance: 4.5%. Losses and Impedance are subjected to tolerance as specified in IS 1180. The transformers should be supplied with first filling of oil confirming to IS 335. The transformer should have both side cable end box with neutral brought out complete all as directed by Engineer - in -Charge, and installation of transformer shall be carried out as per IS-10028and comprising with the following standard fittings/Technical specifications:-(a) Lifting lug for transformer and tank.(b) Earthing terminal rating and diagram plate.(c) Air release device.(d) Oil filling inlet pipe with plug.(e) Drain outlet pipe with brass gate valve.(f) Conservator tank with oil level indicator(g) Silica jel breather(j) First fill of oil upto level including conservator tank with fresh new oil conforming to IS335.(k) Type of connection Delta/Star(l) Type of cooling: Oil and Natural Air.(m) Vector group: DYN 11.(n) Temperature rise over an ambient of 50 °C maximum.(o) Cable end box on both side for HT/LT cables of suitable size.(p) Provision of thermometer with pocket.(q) Provision of oil and winding temperature gauge. 95 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal copper bus bar for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. andcomprising as under: The LT Panel comprising of the following:- Main LT PanelHorizontal copper busbar for 3 phase, 440 volts, 50 Hz, 4 wire system of rating 1600 Amps for phases and 1600 Amps for Neutral. 96 Incoming:-Incomer:-ACB 4 Pole, 415 V, 50 KA with Thermal Magnetic Release (Manual Draw out type) of capacity 1250 AmpMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 1600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, Ics =100% Icu, breaking capacity 35 KA, Ics =100% Icu- 02 No. (For DG AMF Panel & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for APFC Panel & FPB 2 Near bulk Store) (c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 320/315 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for FPB 1 Near Adm Block) (d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 01 No. (for Existing Load)(e) MCCB, thermal magnetic release, 4 pole, 415 Volts,125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for FPB 3 Near Auction Disposal Store)(f) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for MT Complex, Watch tower no 2, Guard room)(g) Digital Ammeter with suitable CT for each outgoing 97 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MS angle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables. Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (Near Admn bldg) 98 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral.Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for 2nd floor & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for 1st floor)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for G floor)( d) Digital Ammeter with suitable CT for each outgoing 99 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.2 (Near Bulk Store) Horizontal Aluminium busbar for 3 phase,440 volts, 50Hz, 4 wire system of rating 600 Amps for phases and 600 Amps for Neutral. 100 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type)- 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 600/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Equipment Load & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Bulk Store)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Watch Tower No. 1)( d) Digital Ammeter with suitable CT for each outgoing 101 Supply, install, test and commissioning of LT Panel, outdoor type, powder coated, 3.00 mm thick CRCA sheet, CPRI approved having, IP 54, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 2 mm thick CRCA sheet, duly compartmentalised for each control gear with louvers and air vent gasket for natural flow of air and suitable provision to accommodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, crack resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.3 (Near Auction Disposal Store) 102 Horizontal Aluminium busbar for 3 phase, 440 volts, 50Hz, 4 wire system of rating 200 Amps for phases and 200 Amps for Neutral.Incoming:-(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 125 Amps, breaking capacity 25 KA- 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 200/5A, CL-1,15 VA - 01 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 100 Amps, Ics =100% Icu breaking capacity 25 KA- 02 No. (for Store Dispatch Complex & Spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 03 No. (for Pol store, Auction disposal store, Covered Hard Standing)(c) Digital Ammeter with suitable CT for each outgoing 103 Supply and fixing poly carbonate street light junction boxes IP 66/67 Weather proof suitable for outdoor installation having minimumsize255 x 355 x 122 including suitableCable connecting Terminals, Cable lugs, including provn of one No. MCB SP 6 Amps for operating the street light fittings, Suitable Cable Glands as per site requirement, all as directed by the Engineer-in-Charge. 104 S & F Street light bracket made out of GI tubing 32/40 mm dia, light grade of length1.2 mtr long bend to shape suitable for security light fitting with necessary MS clamp-02 Nos with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers and 3 core FRLSinsulated sheathed, multistranded copper conductor of size 1.5 sqmm for phase and neutral and 1.5 sq mm for earthing drawn throughthe poles for connection from junction box to light fitting complete etc all as specified.Note: Phase should be Red/Yellow/Blue, neutral should be black and earthing wire should be green in colour. Two runs of cable for phase and neutral and one run of cable for earth will be measured and paid as one unit length. 105 Supply and fixing of LED flood light, 200W, watt 230 V, AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp and made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP protection incl system efficiency >110/120LPW 10KV SPD included Energy saving, environmental friendly and general purpose lighting complete all as specified and directed Engineer-in-Charge. Make : Make : Crompton/Philips/Wipro 106 Supply and fix High Mast Panel outdoor type, suitable to take load up to 6 KW, Conforms to IS/IEC 60947-4-1, Provided with Protection Degree IP 54, Extended wide band (150 Vac - 300 Vac) coil, FRLS (Fire retardant low smoke) Internal wiring, In-built Short-Circuit Protection, Class H Insulation, 3 Phase 415 Volts AC with the following accessories:Phase : 3 Phase, 415 VoltsMax Load Capacity : 6 KWTimer type: AstronomicalContactor Rating : 32 A TPMCB Rating : 63 A TPNMake : Crompton/ Philips/Wipro 107 Supply and laying DWC (Double wall Corrugated) duct pipe outer dia 63 mm and inner dia 50 mmconforming IS 16205 (Part 24 ) for protection ofelectric cable complete all as specified and directed. ( for 10 sqmm St light cable & 16 Sqmm cable) 108 AVIATION OBSTRUCTION LIGHTSupply and fix aviation obstruction light integral aviation light comprising of aluminium housing with polycarbonate enclosure, 240 volt with timer switch and one No.10 A, MCB, SPN 230 V with fixed enclosure complete all as specified and directed by Engineer-in-charge.Make:- Bajaj cat No BGAV 302 LED or equivalent in Philips/Crompton/Surya 109 INCINERATORSupply, fixing and testing of Solid waste Electric Incinerator, single chamber type having a combustion chamber supported with electric coil for generating sufficient heat to burn 100Kg/hr solid waste, retains and re-burns the exhaust gases for minimum of 2 seconds at 850°C, Stainless steel stack for longevity, fitted with a Velocity Cowl as standard, Chamber designed for maximum air flow and circulation which in turn improves efficiency and total burn time, easy to open and close loading door, designed to increase operator safety, steel cladding to reduce risk of infection and increase longevity of system with working temperature not less 450 degree Celsius mounted on foundation as recommended by OEM including electrical control panel with suitable size MCCB, relays & contactor recommended by OEM complete all as complete all as specified and directed.Note:(a) The electrical works including electrical LT panel, internal wiring of the LT panel, suitable size copper wires from panel to Solid waste Electric Incinerator as recommended by OEM to operate the Solid waste Electric Incinerator of capacity 100 Kg/Hr to make Solid waste Electric Incinerator operational is deemed to be included in the rate quoted. (b) All Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed there under and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of Solid waste Electric Incinerator of capacity 100 Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same.(d) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the Solid waste Electric Incinerator and height of plinth shall not be less than 0.5 M 110 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 200 Amps, breaking capacity 36 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 111 ELECTRIC SIRENSupply and fixing Sirens Electronic type Horizontal Double Mounting Three Phase 400/440V, 2800 RPM 50 C/s Flame Proof, audible range 3.5 Km, 2 HP, continuous normal operation for at least 50 minutes with on/off system complete all as specified and directed. 112 Supply and fix advance Sirens controller Electronic type suitable to operate on 3 phase, 415 volt AC 50 Hzcomplete all as specified and directed. 113 Supply & fixing MCCB, thermal magnetic release, 4 pole, 415 Volts, 63 Amps, breaking capacity 25 KA- 01 No.Ics =100% Icu with Sheet metal enclosures fixed properly at directed location and connecting/testing complete all as directed. 114 SOLAR POWER PLANTDesign, supply, installation testing and commissioning of roof top solar photovoltaic power plant (ON-GRID) on roof top of existing bldg of capacity 150 KWp, power evacuation at 415 Volt 3 phase system all as per guidelines/norms issued by MNRE & Indian Metrological Deptt approved Solar Radiation Data viz Direct Normal Irradiance, Global Horizontal radiance etc complete comprising with the following Solar Photo Voltaic Plant.(a) Design, supply, installation, testing and commissioning of Solar PV Modules capable of generating 150 KWp (AC) electricity at 415 Volt 3 phase system. These Solar PV Modules of 540 watt PERC with a modular efficiency of 17-19.84% as per IEC and MNRE standard or as per approved design parameters with Poly/Multi Crystalline Silicon Solar cells of minimum wattage of 540 watt with minimum 144 cells & efficiency not less than 17 -19.84%, conforming to IEC 61215, IEC 61730, IEC 61701. Solar PV Module should be of approved Indian Brand only and Qualify under the Domestic Content requirement (DCR) norms of NVVN/SECI and testing requirement fixed by MNRE. The PV modules shall be warranted for a period of minimum 25 years, Solar PV modules used in system shall be warranted for their output peak watt capacity, which should not be less than 90% at the end of Ten years and 80% at the end of Twenty Five years. Each Solar PV Module must use RF identification tag. The following information must be mentioned in the RFID used in each module:Name of manufacture of PV module, Name of manufacturer of Solar cell, Month & year of manufacturer (for solar cell and module), Country of origin (lt is mandatory to use cells and modules manufactured in India). I-V curve of the module, Wattage, LM, V-M, & FF for the module, Unique Serial No & Model No of the module, Date & year of IEC PV qualification certificate, Name of the test lab issued IEC certificate. The PV modules used in the solar power projects must qualify to the latest edition of the following International Electro technical Commission (IEC) P module qualification test or equivalent BIS Standards. The PV module must be tested and approved by one of the IEC authorized test centres. 115 (b) Material and labour for Module Mounting structure (MMS) fabricated from hot dip galvansied iron section of suitable size with specified tilt angle according to site requirement & optimum angle to achieve maximum benefit of solar energy and suitable to withstand 180 Kmph wind speed all as per approved design parameters as per MNRE standards and to match with the existing site conditions. Necessary roof treatment to avoid any seepage in future shall be done by the Contractor and the amount included in the rate quoted. The roof tiles shall be dismantled and refixed back in original position. Structure shall be built with brick masonry basement of adequate size as per direction at site including all necessary civil work required for the foundation.(c) Supply, laying & Testing of DC cable minimum size 4/6sq mm multi stranded copper conductor, conforming to relevant IS, weather proof UV resistant with operating temperature up to 120 degrees, minimum rated voltage 1100 volt for inter connection of SPV Modules to array junction box including suitable size of cable lugs, male & female MC4 connectors & joints etc.(d) Supply, installation test and commissioning of protection devices MCCB 400 A, isolator and three phase 4 wire LT energy meter, array junction boxes having rating 150 KWp with over voltage protection and surge protection.(e) Supply, installation, test and commissioning of Grid tie Solar Power conditioning unit / inverter of minimum capacity 150 KWp(DC to AC 415 V in Three phase system) all as per approved design parameters & capable of generating output voltage 415 V AC at rated load condition with efficiency not less than 98 %, conforming to IEC 600682-2 NDE standards with power reduction, LVRT with protections for anti-islanding, Ground fault monitoring, Grid Monitoring, AC & DC Over voltage and under voltage protection, AC & DC short circuit lover current protection and DC reverse polarity protection, graphic display etc. all as specified and as directed.(f) Material and labour for Earthing for Lightning protection for SPV modules etc as per IE rule, MNRE guide line & BIS all as per approved plan complete with galvanised earth plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to and including Gl strip 32x6mm size protected with Gl medium grade pipe 40mm dia for earth electrode up to test point by means of GI nuts, bolts, check nuts and washers including earth work excavation, PCC (1:3:6) type Cl pit and RCC cover ( 1:2:4) type Bl and funnel, with necessary charcoal, salt etc complete. 116 (g) Supply and fixing aluminium strip of size 25 x 3mm thick for roof / down conductor fixed on insulators/ saddles of suitable size for SPV modules lightning protection upto interconnection between Roof top LA to Ground Earthing system. (h) AC Cable: Supply and laying of 150 Sqmm LT XLPE insulated, screened PVC bedded, sheathed with multi-stranded aluminium conductor armoured with galvanised steel wire 1100 volts grade heavy duty conforming to IS 150 Sqmm x 3.5Core as per site requirement.Note (i) :-(a) Before quoting the bid, Contractor or his authorised Engineer/consultant must visit the proposed site to study the site condition.(b) Before commencement of work, contractor shall submit drawings & lay out plan with scale including required qty to Accepting Officer for approval.Note(ii):-(a) The mechanical structures, electrical works and overall workmanship of the Grid solar power plant must be warrented for a minimum of 5 years.(b) All Mechanical, Electrical works shall be carried out as per relevant BIS/lS equivalent standard norms only and also in accordance with the latest edition of the Indian Electricity Act / rules formed thereunder and as amended from time to time.(c) Any other works (mechanical, electrical & Civil) connected to installation, testing & functional requirement of solar photovoltaic power plant of capacity 150 KWp (AC) all as mentioned above and which is not mentioned or included in this Schedule A but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to included for the same(d) Contractor shall provide adequate Spares/items required for minimum period of 1 year maintenance including DC & AC items under scope of work.Note (iii) : Design report shall be submitted before execution of Work at site by the contractor toGE for his scrutiny / comments and futher submitted to AO for obtaining approval. 117 DG SETSupplying, installing, testing and commissioning, factory assembled silentDiesel Engine driven generator set, fully wired alternator AC to give an out put of 400 KVA continuously rating at a power factor 0.8 lagging, 3 phase 4 wire, 415 volts 50 Hzsupply, 1500 RPM, directly coupled with diesel engine liquid cooled mounted on common base frame complete with floor mounting fuel tank (service tank) of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturers instructions, vibration damper pads, control panel & other accessories etc and comprising of following.(a)Diesel Engine: Liquid cooled turbo charged with after cooler to deliver suitable BHP at 1500 RPM under NTP conditions of BS 5514 and conforming to IS 10001/ 10002, DIN 6271 & ISO 3046 with an overload capacity of 10% for one hour in any 12 hours continuous operation with the following accessories:. Diesel engine of rated speed at full load electric start developingwithsystem with radiator and including electronic governor control of class A1, engine control panel, lub oil pump, water pump, fuel tank, exhaust pipe with silencer and suitable for electric start with batteries ofadequate capacity and suitable for alternator of specified capacity complete with fly wheel direct/flexible coupling and coupling guard complete.(a) Radiator with blower fan or heat exchanger with guard.(b) Pipe coupling for engine cooling system piping.(c ) Corrosion inhibitor coolant(d) Paper element filters(i) Fuel filter(ii) Lube oil filter(iii) By pass(e) Fly wheel housing and fly wheel to suit alternator.(f) Engine bearing mechanism in fly wheel housing.(g) Shut off coil with safeties for LLOP/HWT/over speed.(h) Dry type air cleaners and vacuum indicators.(j) Residential silencers.(k) Stainless steel exhaust flexible bellows. 118 (l) Motor driven priming pump.(m) Battery charging alternator.(n) Exhaust piping made out of STIC C class, MS pipe inclusive of all accessories and hardware, necessary supports scaffolding as per manufacturers recommendations to sustain back pressure with rain cap.(o) Mineral wool insulation 2 inch thick suitable for 400 degree Celsius temperature cladded with aluminium sheet o30 gauge for the entire length of exhaust pipe.(p) First fill of oil, coolant and diesel during commissioning and 12 hours testing.(q) Interconnecting copper cabling of adequate capacity batteries control.(r ) Fuel pipe class STIC 1 /1.5 /2 dia - 01 lot(s) Self starter 12 volts DC.(t) Electric operated electronic governor.(u) Fuel injection pump.(v) No of cylinders - 12 No VEE(w) Electronic instrument panel, complete with all accessories as per manufacturers specifications displaying the following:-(i) 12vx2 nos -24V Battery. (ii) Water temperature.(iii) lubricating oil pressure.(iv) Engine speed -1500Rpm(v) Engine hours(vi) Frequency.(vii) Voltage.(w) Safety control (Trip and indication).(i) High water temperature(ii) Low lube oil temperature(iii) Overspeed stop 119 (x) Base frame: Sturdy, fabricated welded construction, channel iron base frame (duly painted) for mounting engine and alternator as per manufacturers design alonwith AVM pads.(y) Battery:-24 volts(2x12v Battery) DC, 180AH, maintenance free battery conforming to IS:14257 with leads & terminals (Make- Excide/Amron).(z) Fuel tank:12 hrs. full load diesel storage capacity fuel tank with mounting brackets factory made of 5mm thick HR/MS sheet with level indicator fuel inlet, fuel outlet, air vent, drain plug, in let arrangement for diesel filling fro exterior canopy (without opening its panel) etc complete all as specified and directed.(aa) Isolator panel with 250 amp MCCB(ab) Auto logic panel for automatic stat(b) Alternator: Alternator suitable rated for 400 KVA, 0.8 pf , 415 volts, 3 phase, 4 wire, 50 Hz at 1500 RPM, self excited and self regulated with AVR brushless, screen protected, drip proof , insulation class-H, IP -23, voltage regulationgrade - VG 3 self ventilated and conforming to BS: 5000 / IS: 4722 suitable for engine as mentioned here-in before, conformig to IS: 13364(part-1)Make: KOEL GREEN / stampford/crompten/kirloskar/Greaves(c) Acoustic Enclosure:- M & L for acoustic enclosure for the above 400 KVA DG set to reduce noise level to 75 dB measured at 1.0 meter distance for audible frequencies as per guide of Central Pollution Control Board andmanufacturers specification and comprising of following from authorised GOEMs of Gen Set manufacturers specified :-(i) Sound insulation : 100mm thick Rock wool (Density 64 Kg/Cum).(ii) Outer body : 1.6mm thick CRCA(iii) Door : 1.6mm thick CRCA(iv) Base frame : ISMC 300(v) Inside illumination : 1 No.- 1 x 18 watt LED fitting of make Phillips/ Bajaj/ Crompton.(d) AMF Control panel:- Factory fabricated cubicle type, free standing, floor mounted, indoor type, IP-43, AMF control panel, provided with removable rear panels & hinged front panel for easy accessibility, fabricated out of not less than 2.0mm thick CRCA sheet including two coats of powder coated paint over a coat of red oxide primer etc and comprising of following: 120 (e) AMF control circuit with 4 pole MCCB 630 Amps - 2 nos, with ultimate breaking capacity Icu-50 KA at 415 volts and microprocessor release conforming to IEC 60947 Part-I with breaking capacity Ics=Icu at 415 volts , thermal overload setting 70% to 100%, short circuit setting 5 to 10 times-02 Nos. for main supply & DG set supply with HRC back up fuse complete with all DC control relays/ Line voltage monitor (LVM) as per OEM specifications incorporating motorised stored energy operating Engine start, stop, three attempt starting facility and failure to start etc.(f) Digital load manager : Three phase 4 wire indicating V,I,PF, KVA, KW, F of Enercon make with serial communication port model No.EM6400 with class 1.0 accuracy meter or equivalent make suitable rating of CT per phase- one No.(iii) Indication lamp R, Y, B with 3 Nos. of 2A HRC fuses-10 sets.(iv) Bottom gland plate for incoming and outgoing cables.(v) Circuit diagram plate.Note :- DG set should be as per CPCB -4 latest norm wef 01 July 2023 of National Clean Air programme (NACP) Act 1981. 121 Supply, install, test and commissioning of LT Panel, Indoor type, powder coated, 2.00 mm thick CRCA Sheet, CPRI approved having, IP 43, MSangle iron section of 50X50X6 mm frame, suitable for 3 Phase 415 volts 50 Hz, AC supply,bus bar chamber with Horizontal aluminium bus bar 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators, factory fabricated, roof canopy, with front and back openable double door system lockable/openable by keys from both sides, louvers & air vent gasket for natuaral flow of air.The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The inner shell be made out of 1.6 mm thick CRCA Sheat duly compartmentalised for each control gear with louvers and air vent gasket for natuaral flow of air and suiatable provision to accomodate incomer/outgoing MCCBs/MCBs and metering devices and suitable busbar chamber for passing and connecting UG cables.Providing bus bar for phases and neutral and shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on suitable size F class insulators made on non hygroscopic, non combustile, track resistant, high strength FRP/SMC/DMC material at an interval of not more than 300 mm through out the length of the TPN bus bar all as specified and directed by the Engr-in-Charge. Feeder Panel No.1 (DG Panel ) 122 Incoming:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 630 Amps, breaking capacity 36 KA - 01 No. Ics =100% IcuMetering Unit:- (a) R Y B Indications (LED Type) - 1 sets(b) Digital Multi function meter - 01 No.(c) CTs - 800/5A, CL-1,15 VA - 1 setOutgoing:-(a) MCCB, thermal magnetic release, 4 pole, 415 Volts, 400 Amps, Ics =100% Icu breaking capacity 36 KA- 02 No. (for Package AC Bulk Store & spare)(b) MCCB, thermal magnetic release, 4 pole, 415 Volts, 160 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Pump House & Fire Pump)(c) MCCB, thermal magnetic release, 4 pole, 415 Volts, 80 Amps, Ics =100% Icu breaking capacity 25 KA- 01 No. (for Incianator)(d) MCCB, thermal magnetic release, 4 pole, 415 Volts, 32 Amps, Ics =100% Icu breaking capacity 25 KA- 07 No. (for Terrace pump 1, Terrace pump 2, Power House, High mast 1, High mast 2, Street Light)(e) Digital Ammeter with suitable CT for each outgoing(f) Astro Time switch for 3 phase 20A- 1 No(g) 3 Phase Power contactor 20 amps, with 230 coil 123 SEWAGE DISPOSALM & L for laying of DWCPE sewage pipes line 200 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 124 M & L for laying of DWCPE sewage pipes line 150 mmdia borepipe sftiffnessclass SN 8 includingsealing of joints fittings etc complete with collers complte all as spcified and directed 125 COMPOUND WALLS & F Concertina Coil of 600/700 mm outer dia made out of 2.60 mm dia spring steel wire dipped in corrosion preventive fluid (rusilo 901) of castrol make each coil having min 50 turns (circles) covering 6 m and an average weight not less than 8.57 Kg (plus or minus 5 %) incl handle and spike at both ends of coil erected in position on top of mild steel angle by fixing with 1.70 mm GI wire for securing, coil with fish hook bars, incl necessary welding to MS Sections etc all as specified and directed. 126 GREEN BUILDING NORMS(GRIHA CONCEPT)Supply and Install Organic Waste Converter fully automatic having capacity 50Kg/day, having internal tank made of high quality stainless steel while external panels are powder coated for enhanced product life with necessary electric control panel, cabling necessary civil works for installing machine etc with following requirements:-Type of machine: Fulley automatic in-vessel composterComposting method: 24 Hrs. Micro-organisms-based compostingmachine Type of microganism used: Heat resistant thermophilic bacteria Final Output: Dry organic Soil conditioner/Soil supplementsCycle time: 24Hrs Volume reduction in 24Hrs: 80-85% Internal tank: Stainless steel type Main agitator Shaft: Stainless steel type Input voltage: 415VSpecial features: VFD as standard across all models, Touchscreen standards Daily waste processing: 150Kgs Rated capacity: 7KWPower consumption (KWH par cycle): 13-15Length: 1650, Width: 850,Height: 1455 127 Supply, installation, testing and commissioning Three phase energy meter with the following specifications: Microprocessor based three phase, smart electricity meter, equipped with a bi-directional cellular (NB-IoT) communication that allows it to interact with the head end system (HES) for data collection and configuration with adequate security including electronic static pre paid cum postpaid energy meter rating 415 Volts, 50 Hz of range 10-100 Amps, complying to IS16444:2015 (reaffrimed 2020) and conforming to IS 3779 with LED display and parameters like Voltage, Current, Frequency, Power, Power factor, KWH/KVA, default in built dual source, inbuilt long range (LORAWAN) Communication suitable for outdoor LoRa data accumulator and also compatible for Prepaid and Postpaid online energy monitoring billing system with disconnection /reconnection through remote software / data export to ERP complete with 5 Years warranty.Note:(a) The contractor would be responsible for removing the existing meter, noting down the reading and depositing it with the MES AGE E/M store complete all as specified & directed.(b) The Energy Meter to be capable of running in both prepaid and postpaid mode.(c) The meters to carry 5 year warranty. (for entire system) 128 Supplying, Fixing, Commissioning and testing of configuration of cloud Hosted multi user web based software with following modules:(i) Head End System (HES): to acquire meter data automatically from DCU sand monitor parameters acquired from meters.(ii) Meter Data Management ModuleThe meter data management module would be responsible for collecting the data from the data concentrator and make the data available to the billing system. The system would support offline meter(a) 30 min instantaneous data from all the meters for seven parameters Cumulative Energy. Cumulative Apparent Energy (as applicable), Power, Current, Voltage, Power Factor and Frequency(b) Monthly billing survey data for cumulative energy and max demand(iii) Billing Module: The billing module would collect the data from the meter data management module, calculate the energy consumption, calculate billing determinant and make energy data/billing data available to admin and end users. The billing module would include functionalities for tariff setup, bill format setup, bill adjustment, occupation billing and vacation billing. It would allow postpaid and prepaid functionality as required.(iv) Occupation and Vacation Module: The system would support occupation/vacation based on the unit catagories. The system would support automatic data capture on occupation and vacation events.(v) Website: There would be a dedicated website forAGE/GE and BSO team to view all the data and information alongwith customer portal for use of customer. The designated users in MES would have the admin access to the application. The MES Staff would also have the access to the key information on mobile App (AndroiandiOS based) for admin use complete all as specified and directed.(vi) Customer Module: The system would include a customer portal for the resident/occupants to login and view their own energy /billing data and recharge facility. There shall be consumer App (Android and iOS based) also to log in and view their own energy/billing data and recharge facility.(vii) Communication Module :The system would provide communication of energy data and bills via print, email and sms methods. 129 (viii) Meter Master Data: The system would support meter data repository. The system would support meter replacement process.(ix) Excel Export: the system would support export of metering and billing data in excel and pdf format.(x) Energy Accounting module: The system would include features of energy accounting, the system would to able to account for total energy block wise, facility wise and would also allow calculations of the unaccounted energy in case total energy meter is also available.(xi) Prepayment/Recharging Facility:The system should periodically monitor the energy consumption of prepaid consumers and decrease the available credit based on the consumption. The system should allow online/digital recharging through consumer App (Androidand iOSbased) and Web portal. The configuration and necessary arrangement for payment gateway and E-MRO facility shall be deemed to be included in the quoted rate. The system should sendconnect/disconnect command on the basis of available credit.Low credit alarm: The system will give an alarm over the consumer App and SMS to the registered mobile number in case the credit in the meter goes down be low apredefined limit.Emergency credit: The meter will work even when the credit falls down to zero to prevent disconnection. This limit shall be configurable. The system should support happy hours inorder to prevent disconnection in non working hours and on holidays. The Happy hours should be configurable complete all as specified and directed. 130 Supply, Installation, Testing and Commissioning of DCUs/Gateways and the arrangement of Sim cards or Internet to enable reliable medium for two-way communication between Smart Meter & HES. The data acquisition (Push/Pull) frequency shall be, configurable. It shall push events such as tamper, power off etc. to HES immediately on occurrence/receipt from meters. It shall have provision for the cellular, WiFi and Ethernet communication for the backhaul to HES. It shall be capable to handle data of minimum 1000 Nos. of any type of smart meter (1ph/3ph).It shall be able to communicate with the nearest meters at a distance of at least 500 m, depending on topographical features. Communication of the nearest meters with other meters shall be established through appropriate mesh formation. RF Mesh shall support self-forming and self-healing features. The equipment shall be weather proof and dust proof (minimum rating: IP54 for indoor and IP65 for outdoor installation). It shall have rechargeable battery with backup for 1(one) hour for normal meter reading, to push tamper event, carry out on demand reading, etc complete all as specified and directed. 131 Hosting GPRS (4G) charges for Gateway for five years from the date of completion F Including 2 years waranty and 2 years Maintinance after warranty) Make:-Airtel/Jio/Vodafone 132 Supply and installation of digital Water flow meter 50mm suitable for domestic and commercial applications complete all as specified and directed. 133 Supply and installation of digital Water flow meter 40mm suitable for domestic and commercial applications complete all as specified and directed. 134 ARBORICULTUREM & L for excavation of pits size 30cm x 30cm x 30cm in loose soil and filling the pit with mixture of river sand and approved top soil in the proportion of 1:3 mixed with 30% of cow dung powder, 100gms of bone meal and 100gm of neem cake powder 135 All as per item No 13.121 above but pit size 60cm x 60cm x 60cm 136 Supplying and planting red palm or royal palm healthy sapling having 45cm height and shall have a minimum height of 65cm after 6 months 137 Supplying and planting coconut tree healthy sapling having 75cm height and shall have a minimum 95cm after 6 months. 138 Supplying and planting flower plants(Champa/ hybrid hibiscus/ Hybrid west Indian Jasmine/ Hybrid Plumeria white plant/ Panama yellow plant/ Oleander) healthy sapling having 10cm minimum height and shall have a minimum 25cm to 30cm height after 6 months. 139 Supplying and planting phylanthus healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 140 Supplying and planting bougainvillea colour flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 141 Supplying and planting song of India flower plants healthy sapling having 15cm to 30cm height and shall have a minimum 45cm height after 6 months. 142 Supplying and planting dracaena flower plants healthy sapling having 15cm to 30 cm height and shall have a minimum 60cm height after 6 months. 143 Supply and planting mexican grass including providing manure as directed. 144 PILE FOUNDATIONBoring 450 mm dia piles to any depthin any type of soil/ strata by anyapproved method, complete all as shown on drawings and as specified anddirected.Note:- The quoted rate shall include for mobilization and demobilisation of piling equipment, making approaches to site or point of pile boring if necessary. Nothing extra shall be paid on this account. 145 Boring for bored cast in situ pile 600 mm dia to any depth through any type of soil / strata, using DMC method (Direct Mud Circulation)and getting out & disposal of spoil to any distance outside of MD land , complete all as specified and as directedby the EngineerIn Charge 146 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in cast in situ DMC bored pile of any length / any sectionscomplete all as specified and as shown on drg 147 M & L Reinforced cement concrete of grade M-35 design mix (RMC) as per IS-456using 20 mm graded stone aggregate in pile caps / grade beams complete all as specified and as shown on drg 148 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for bored cast in situ piles of any length and any dia all as shown on drgs including cut to length, bend to required shape, cranking/hooking ends if necessary and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 149 Providing TMT bars (CRS/HCRM/CRM) in reinforcement 10 mm dia and over for pile caps and grade beams, cut to length, bent to shape required, hooking ends and binding with and including 0.9mm dia MS wire (annealed) or welding so as to secure the bar firmly in position/ required shape complete all as specified and shown on drgs (Fe-500D). 150 All as per item No 13.136 here-in-before but5mm dia and over upto and including 10mm dia as in helicals for piles and stirrups for grade beams complete all as specified and directed. 151 M & L for providing PCC (1:4:8) type D-2 using 40 mm graded stone aggregate for concrete layer below pile caps foundation complete all as specified and directed. 152 Formwork to sides of pile caps/ grade beams and similar work, rough finished surface of concrete flat all as specified and as directed. 153 M & L for carrying out non destructive integrity test all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed all as specified and directed. 154 M & L for carrying out Initial Load test (vertical load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013 including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 155 M & L for carrying out Initial (lateral load test) cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 156 M & L for carrying out Initial load test ( pull outtest) of cast in situ piles of 600 mm dia as per IS 2911 (Part 4) 2013including mobilising and removing the testing equipments from site after testing is completed all as specified and directed.(Note :- Providing and installing test piles shall measured and paid separately) 157 M & L for carrying out Routine load Test (Vertical load)all as per IS 2911 (Part 4) 2013 for 600 mm dia cast in situ piles including mobilising and removing the testing equipments from site after testing is completed 158 Testing of piles (Initial load test) for 450mm dia cast in situ bored piles all as per IS including removing the testing equipments from the site after testing is completed all asspecified and as directed
Contract Date: Jul 23, 2025 Contract Value : 57.42 Crore
Statutory Bodies & Commissions/Committees No of Bidders 7
15.
Public Administrative Department #7491419 AOC
Tender For Annual Maintenance Of Electric Department For Year 2025-26 - Supplying anderecting HMS PVC conduitFRLS grade 20 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON. 3 Supplying and erecting HMS PVC conduit FRLS grade25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON. 4 Supplying and erecting HMS PVC conduit FRLS grade 32 mm dia. with PVC accessorieson wall / ceiling as per specification No: WG-MA/CON. 5 Supplying anderectingPVCtrunking (PVC casing-n-capping)ofsize20 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 6 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize25 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 7 Supplying anderectingPVCtrunking (PVCcasing-n-capping)ofsize32 mm with accessorieson wall/ceiling as per specification No: WG-MA/CON. 8 Supplying and erecting mains with 2x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 9 Supplying and erecting mains with 1x1.5 sq.mm FRLSHcopperPVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 10 Supplying and erecting mains with 2x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 11 Supplying and erecting mains with 1x2.5 sq.mmFRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 12 Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 13 Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 14 Supplying and erecting mains with 2x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW 15 Supplying and erecting mains with 2x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 16 Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 17 Supplying and erecting mains with 3x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 18 Supplying and erecting mains with 3x6 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 19 Supplying and erecting mains with 3x10 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 20 Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 21 Supplying and erecting mains with 4x25 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW 22 Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV 23 Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi strandedcopper Industrial cable for voltage grade up to 1.1 kV 24 Supplying and erecting mains with WP 2 x 2.5 sq. mm. 1100 V grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 25 Supplying and erecting mains with WP 2 x 4 sq. mm. 1100 V grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 26 Supplying and erecting mains with WP 2 x 6 sq. mm. 1100 V. grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 27 Supplying and erecting mains withWP 3 x 4 sq. mm. 1100 V. grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 28 Supplying and erecting mains withWP 3 x 6 sq. mm.1100 V. grade aluminium PVCinsulatedandPVC sheathed wires on G.I. bearer wire No. 8 SWG complete erectedwith required size ofporcelainreelinsulators and 16 SWG G.I. binding wire. 29 Supplying and erectingmodular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 30 Supplying and erectingmodular type switch 16Aduly erected on provided plate and box with wiring connections complete. 31 Supplying and erectingmodular type bell-push 6A / 10A duly erected on provided plate and box with wiring connections complete. 32 Supplying and erectingmodular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete. 33 Supplying and erecting modular type Two way switch 6A / 10A (2 Module),duly erected on provided plate and box with wiring connections complete. 34 Supplying and erectingmodular type switch 16 / 20 Awith indicator,duly erected on provided plate and box with wiring connections complete. 35 Supplying and erectingmodular type switch one way 16 / 20 A,duly erected on provided plate and box with wiring connections complete with neon indicator. 36 Supplying and erectingmodular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete. 37 Supplying and erectingmodular type 3 pin 6Amultisocket with safety shutter, duly erected on provided plate and box with wiring connections complete. 38 Supplying and erectingmodular type 3 pin 6 / 16Amultisocket with safety shutter,duly erected on provided plate and box with wiring connections complete. 39 Supplying and erectingmodular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. 40 Supplying and erecting PVC Surface modular switch box with double mounting plate for 1 module complete duly erected. 41 Supplying and erecting PVC Surface modular switch box with double mounting plate for 2module duly erected. 42 Supplying and erecting PVC Surface modular switch box with double mounting plate for 3module duly erected. 43 Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected. 44 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6module duly erected. 45 Supplying and erecting PVC Surface modular switch box with double mounting & front plate for 8 module complete duly connected. 46 Supplying and erecting PVC Surface modular switch box with double mounting plate for 12module duly erected. 47 Supplying and erecting PVC Surface modular switch box with double mounting plate for 16 / 18 module duly erected. 48 Supplying and erectingmodular pop up Box 8 module erected with providedAV/ HDMI , RJ 45,6 A electricalsockets and switch on provided table. 49 Point wiring for ceiling fan in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire, modular type switch, earthingand required accessories as per specification No: WG-PW/SW 50 Point wiring for independent plug in PVC trunking (casing-capping) with 1.5 sq.mm(2+1E) FRLSH grade copper wire, modular type switch,earthing and required accessories as per specification No: WG-PW/SW 51 Wiring for plug on board withSwitch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WG-PW/CW 52 Supplying and erectingLED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing,polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 53 Supplying and erectingrectangular shaped LEDPanel Light(1200mm X 300mm) Max. 35 Whaving CRCA powder coated housing,polystyrene diffuser havingsystem lumens output of Min. 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%,THD<10%, p.f. >0.95, operating range of120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50,including driver,having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty. 54 Supplying and erectingbulk head LED fittingmax. 10Wwith high transitivity diffuser withsystem lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg.,THD<10%,p.f. >0.95, operating range of140-260V, in built surge protection of 2.5 kV, Life class of50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty. 55 Supplying and erecting CRCA powder coated corridor/passage light LED fitting (4 feet) Max. 17Wwith high transitivity diffuser withsystem lumens output of Min. 2000 lumens , min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., Ripple<5%, THD<10%,p.f. >0.95, operating range of120-270V, surge protection of 4 kV, Life class of50,000 Hrs. at L70B50, includingdriver, with end caps on provided PVC Block / wooden board with 3 years warranty. 56 Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22Wwith high transitivity diffuser withsystem lumens output ofMin.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%,THD<10%,p.f. >0.95, operating range of200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty. 57 Supplying and erecting condenser 4 microfarad for fluo. Fitting as per specification no FG-FG/AS7. 58 Supplying and erecting integrated LED street light fitting18 to 22W IP65 & IK08 class having single piece pressure die-cast aluminium housing,having system lumens output of Min. 1800 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 59 Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification NoFG-ODF/FLS2. 60 Supplying and erecting integrated LED street light fitting26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing ,having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 61 Supplying and erecting integrated LED street light fitting 40 to 50W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 4400 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 62 Supplying and erecting integrated LED street light fitting 60W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 6600 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 63 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 64 Supplying and erecting integrated LED street light fitting 85-90W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 9300 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 65 Supplying and erecting integratedLED street light fitting 100-110W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 11000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 66 Supplying and erecting integrated LED street light fitting 120W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 13000 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 67 Supplying and erecting integrated LED street light fitting 130-140W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 15600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 68 Supplying and erecting integrated LED street light fitting 160-170W IP65 & IK08 class having single piece pressure die-cast aluminium housing,havingsystem lumens output of Min. 19000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50,including driver complete with 3 Years warranty as per specification NoFG-ODF/FLS2. 69 Supplying and erecting integrated LED flood light fitting Max. 30W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min. 3000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 70 Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 71 Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 72 Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 73 Supplying and erecting integrated LED flood light fitting Max. 120W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min.14500 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 74 Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing,having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 75 Supplying and erecting integrated LED flood light fitting Max. 195W IP65 & IK07 class having pressure die-cast aluminium housing,havingsystem lumens output of Min. 23400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50,including driver with U shaped bracket with 3 Years warranty as per specification NoFG-ODF/FLS2. 76 Supplying and erecting integrated LED Post Top45W IP65 & IK10 class having die cast aluminium housing with UV protected polycarbonate diffuser,having system lumens output of Min.4500 Lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 2 kV, Life class of 30,000 Hrs. at L50B50 , including driver complete with 2 Year warranty as per specification NoFG-ODF/FLS2. 77 Supplying and erecting Gate/garden light fitting with 200mm dia. glass bowl suitable for upto 12W LED Lampon provided pipe as per specification No. FG-ODF/GLT 78 Supplying and erecting Gate/garden light fitting with 300mm dia. glass bowl suitable for upto 12W LED Lamp on provided pipe as per specification No. FG-ODF/GLT 79 Supplying & erecting integral post top lantern fixtures (mushroom type) suitable for LED lamp upto 12 W consisting of clear acrylic top cover, cast aluminium pole cap complete with accessories on provided pole /bracket as per specification no. FG-ODF/PTL 80 Supplying & erecting integral post top lantern fixtures (globe type) suitable for LED lamp upto 12 W consisting of aesthetic round clear acrylic top cover, cast aluminium pole cap on provided pole /bracket as per specification no. FG-ODF/PTL 81 Supplying & erecting integral post top lantern fixtures (light house type) suitable upto LED 18 W Lamp consisting of combination of spun aluminium canopy & clear acrylic top cover, cast aluminium pole cap on provided pole/ bracket as per specification no. FG-ODF/PTL 82 Supplying and erecting integrated LED Highbay Fitting70W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,having system lumens output of Min.10000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 83 Supplying and erecting integrated LED Highbay Fitting100W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,having system lumens output of Min. 15000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 84 Supplying and erecting integrated LED Highbay Fitting135W IP65 & IK08 class having die cast aluminium housing with polycarbonate diffuser with integrated optics,havingsystem lumens output of Min. 20000 Lumens, min. efficacy of 145 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of140-240V, inbuilt surge protection of 4kV, Life class of 50,000 Hrs. at L50B50 , including driver complete with 3 Year warranty as per specification NoFG-ODF/FLS2. 85 Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 86 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 87 Supplying and erecting street light Wall bracket made from 25 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB 88 Supplying and erecting street light Wall bracket made from 40 mm. dia ‘ G.I. pipe 1.2 m. in total length complete as per specification no. FG-BKT/WB 89 Supplying and erecting Street light bracket for erection of Single fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC 90 Supplying and erecting Street light bracket for erection of Double fitting made from 40 mm. dia ‘B’ class G.I. pipe 1.0 m. in length along with pole cap of 300 mm length 100 mm dia duly welded as per specification no. FG-BKT/BPC 91 Supplying and erecting Street light bracket for erection of Single fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/BPC 92 Supplying and erecting Street light bracket for erection of Double fitting on tubular welded pole with 40 mm. dia 1.0 m. length “B” class G.I .pipe along with pole cap of 125mm dia 600 mm long duly welded as per specification no. FG-BKT/BPC 93 Supplying and erecting Control gear 1x250W for HPSV/MH lamp with all accessories for NON Integral Flood light fittings suitable for complete 94 Supplying and erecting Control gear for NON Integral Flood light fittings suitable for 1x400W HPSV/MH lamp with all accessories complete. 95 Supplying and erecting Control gear for NON Integral Flood lightfittings suitable for 2x250W HPSV/MH lamp with all accessories complete. 96 Supplying and erecting Control gear for NON Integral Flood light fittings suitable for2x400W HPSV/MH lamp with all accessories complete. 97 Supplying and erecting electronic type Driver for Outdoor LED Fittingsupto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 98 Supplying and erecting electronic type Driver for Outdoor LED Fittings 26W-45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 99 Supplying and erecting electronic type Driver for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 100 Supplying and erecting electronic type Driver for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 101 Supplying and erecting electronic type Driver for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 102 Supplying and erecting electronic type Driver for Outdoor LED Fittings151W-200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 103 Supplying & erecting 0.5W, 230V integral type LED Lamp suitable for B-22/E-27 base. 104 Supplying and erecting Pigmy /candle lamp miniature type coloured / white. 105 Supplying & erecting 3W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 106 Supplying & erecting 5W-7W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 107 Supplying & erecting 10-12W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 108 Supplying & erecting 14W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 109 Supplying & erecting18W, 230V integral type LED Lamp suitable for B-22 / E-27 base. 110 Supplying and erecting bracket fan 400 mm. sweep A. C. 230 volts 50 cycles 1350 RPM. Oscillating type, plastic or metal blades chrome plated guard with speed regulator and moisture proof treatment to winding and with ‘E’ class insulation. 111 Supplying and erecting air circulator 600 mm. sweep oscillating type, wall mounting 1440 RPMwithoutspeedregulator, overheat protection unit, totally enclosed, flame proof motor suitable for 230/250 volts single phase, 50 cycles A.C. supply, core lead wire and with moisture proof treatment to winding and with ‘E’ class insulation. 112 Supplying pedestal type air circulator 450 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM with speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin 5A. plug top complete with moisture proof treatment and ‘E’ class insulation. 113 Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation. 114 Supplying and erecting exhaust fan medium duty 230 V A.C. 50 cycles 225 mm. 1400 RPM with condenser complete erected in position with necessary materials. Fan motor with moisture proof treatment and ‘E’ class insulation. 115 Supplying and erectingenergy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF 116 Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control/compatible speed regulator, Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF 117 Supplying and erecting condenser 2.5 micro farad for ceiling fan 118 Erection ofdepartmentallysupplied ceiling fan with necessary materials complete. 119 Erectionofdepartmentallysupplied exhaust fan with necessary materials complete. 120 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete. 121 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigeranthaving 22SWG thickness and inner dia/size 16mm complete. 122 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 22mm complete. 123 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 32mm complete. 124 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 35mm complete. 125 Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 42mm complete. 126 Supplying and erecting 12V/130Ah to 135Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 127 Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete. 128 Supplying and erecting 12V/180Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 129 Supplying and erecting 12V/200Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete 130 Providingservicing of 1/1.5/2/3 TR capacity split/window air conditioning unit with all necessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indoor as well as outdoor unit complete and submitting report to Engineer incharge. 131 Providing annual comprehensive maintenance contract for 1 TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job excludes sheet metal work and plastic material. 132 Providing annual comprehensive maintenance contract for 1.5TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. 133 Providing annual comprehensive maintenance contract for 2TR split/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material. 134 Providing annual comprehensive maintenance contract for 3TR to 4.5TRsplit/tower/window air conditioning unit complete as per terms and conditions. Job includes 1) quarterly servicing 2) on call repair 3) replacement of all spares within 24 hours 4) sending standby manpower for VIP movement. The job exclude sheet metal work and plastic material 135 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1TRby new one of same capacity with guarantee for one year with provided refrigerant complete. 136 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 1.5TR by new one of same capacitywith guarantee for one year with provided refrigerant complete. 137 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2TR by new one of same capacitywith guarantee for one year with provided refrigerant complete. 138 Providing replacement of existing unserviceable rotary/scroll compressor of air conditioner 2.5TR to 4.5TR by new one of same capacitywith guarantee for one year with provided refrigerant complete. 139 Providing flushing out cooling coil and condenser coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure, complete. 140 Providing brazing pipes and checking leakages in the split/window unit duly with dry nitrogen pressure, complete. 141 Providing replacement of unserviceable starting relay for AC unit. 142 Providing replacement of unserviceable starting capacitor for AC unit. 143 Providing replacement of unserviceable running capacitor for AC unit. 144 Providing replacement of unserviceable fan motor capacitor for AC unit. 145 Providing replacement of unserviceable PCB for AC unit upto 3TR capacity. 146 Providing repair of faulty PCB for AC unit upto 3TR capacity. 147 Supplying and installing of new fan motor for condenser for air conditioning unit 148 Supplying and installing of new fan motor for indoor unit of air conditioner up to 3TRsuitable to operate on 230/250V,A.C. or 280-340V DC supply having 4 to 8 poles as per requirement. 149 Supplying and installing new fan blade outdoor unit for AC unit. 150 Providing replacement of blower of indoor unit for AC unit. 151 Providing replacement of remote of indoor unit for AC unit. 152 Providing vaccumising the airconditioner system and charging with refrigerant R32 for AC unit. 153 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for AC unit. 154 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 1TR window/split AC unit. 155 Providing vaccumising the airconditioner system to 200 micron and charging with R32 refrigerant for 1.5TR window/split AC unit. 156 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 for 2TR window/split AC unit. 157 Providing vaccumising the airconditioner system to 200 micron and charging with refrigerant R32 refrigerantfor 3TR window/split AC unit. 158 Providing replacement of existingunserviceablecompressor of 40 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. 159 Providing replacement of existingunserviceablecompressor of 60 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. 160 Providing replacement of existing unserviceable compressor of 150 litre cooling capacity water cooler by new one of same capacity along with suitable refrigerant with guarantee for one year. 161 Providing replacement of existingunserviceable condenser coil of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 162 Providing replacement of existing unserviceable SS water tap of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 163 Providing replacement of existingunserviceable relay40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 164 Providing replacement of existingunserviceablethermostat of 40/80/150 litre cooling capacity water cooler by new one of same capacity, testing to the satisfaction of site engineer for cooling and along with guarantee for one year with suitable refrigerant. 165 Supplying and erecting candle filter with filter pot for water cooler. 166 Supplying and erecting connector pipe for candle filter of water cooler. 167 Providing replacement of base tray of water cooler of any capacity. 168 Supplying and erecting quartz electronic timeswitchhaving 24 hour dial to work on 250 V 50 cycle AC having built in rechargeablenickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16A to use independently or in conjunction with contactor. 169 Supplying and erecting two pole power contactor 230 V, 32 A for time switch complete erected on provided wooden block/ box, with necessary materials. 170 Supplying and erectingfour pole power contactor 430 V, 16 Afor time switch complete erected on provided wooden block/ box, with necessary materials. 171 Supplying and erectingfour pole power contactor 430 V, 40 Afor time switch complete erected on provided wooden block/ box, with necessary materials. 172 Supplying and erecting programmable digital almanac timer microcontroller based with real time clock to operate on derived switching “ON” and switching “OFF” street light asper dailysunset and sunrise respectively automatically having 4digitLEDcontinuous time display, relay output 230 V / 10A with 10 hrs. battery backup and manual over drive facility capable to drive different capacity contactors timer erected in provided M.S. box. 173 Supplying &erecting four poleON LOAD changeover switch, 415V,100A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 174 Supplying &erecting four poleON LOAD changeover switch, 415V, 200A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 175 Supplying &erecting four poleON LOAD changeover switch, 415V, 315-320A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 176 Supplying &erecting four poleON LOAD changeover switch, 415V, 400A, open execution having staggered termination, phase barrier, shroud termination and terminal cover along with auxiliary contacts and ready to upgrade with fuse protection kit,rotary handle, operational current category AC23A complying to IS/IEC 60947-3 Part-1/3. 177 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 100-125A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging,connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 178 Supplying and erecting ON LOAD four pole automatic transfer switch, 415V, 200A, 50 Hz with enclosure, flexibility of neutral connection, line and load reversibility, changeover with phase barriers, source separator, terminal covers along with staggered termination for cable connection and ATS controller with provision of time delay protection of OV, UV, phase sequence changing, single phasing and event logging,connected with provided leads complete complying to IS/IEC 60947-3 Part-1/6 . 179 Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB 180 Supplying, erecting & marking SPMCB 6A to 32A, C-serieswith rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 181 Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 182 Supplying, erecting & marking SPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 183 Supplying, erecting & marking SPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 184 Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 185 Supplying, erecting & marking DPMCB 6 A to 32 A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 186 Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 187 Supplying, erecting & marking DPMCB 40A to 63A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 188 Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 189 Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 190 Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB 191 Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kAin provided distribution board as per specification no. SW-SWR/MCB 192 Supplying, erectingand marking double pole isolator only switch version of miniature circuit breakerof40Awith required wiring connections and lugs etc. in provided distribution board. 193 Supplying, erectingand marking triplepoleisolatorsonlyswitch versionofminiaturecircuitbreaker of 40A with required wiring connections and lugs etc. in provided distribution board. 194 Supplying, erecting and markingtriple pole isolators only switch version of miniature circuit breaker of 63Awith required wiring connections and lugs etc. in provided distribution board. 195 Supplying, erecting and markingtriple pole isolators only switch version of miniature circuit breaker of 100Awith required wiring connections and lugs etc. in provided distribution board. 196 Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 40A in provided distribution board. 197 Supplying, erecting and markingfour pole isolators only switch version of miniature circuit breakers of 63Ain provided distribution board. 198 Supplying, fixing and commissioning MCB type change over switch 4 pole, 40A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS 199 Supplying, fixing and commissioning MCB type change over switch 4 pole, 63A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS 200 Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 2 ways (2 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 201 Supplyingand erecting single pole and neutral distributionboard (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB 202 Supplying & erecting CRCA sheet metal enclosures of 1.2mm thickness with 20A, 2 pin plug & earth socket and 20A, 3 pin plugtop with 20A/30A single pole MCB having rated short - circuit breaking capacity (Icn) 10kA complete erected on angle iron/ GI frame. 203 Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame. 204 Providing & erecting 4 Pole MCCB, 415 V, 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact.MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 205 Providing & erecting 3 Pole MCCB, 415V, 200A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 206 Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload) setting and adjustable magnetic setting with provided leads, provision for installation of shunt/UV/trip alarm contact and MCCB should have phase barriers both sides, with insulation withstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-SWR/MCCB 207 Supplying, erecting & commissioning 2 pole RCCB 63A, electromagnetictype with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB 208 Supplying, erecting & commissioning 4 pole RCCB 63A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication completeas per specification no. SW-RCCB/RCCB 209 Providing, erecting & commissioning 4 pole RCCB 40A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivity complete as per specification no. SW-RCCB/RCCB 210 Providing, erecting & commissioning 4 pole RCCB 63A, with added immunity to avoid DC pulse tripping with 30/100/300 mA sensitivitycomplete as per specification no. SW-RCCB/RCCB 211 Providing, erecting& commissioning 4 pole RCCB 100A, with added immunityto avoid DC pulse tripping with 30/100/300 mA sensitivitycompleteas per specification no. SW-RCCB/RCCB 212 Supplying and erecting porcelain base iron clad cut out HC type 415V, 16A erected on polished wooden block. 213 Supplying and erecting porcelain base iron clad cut out HC type 415V, 32Aerected on polished wooden block. 214 Supplying and erecting porcelain base iron clad cut out HC type 415V, 63Aerected on polished wooden block. 215 Supplying and erecting porcelain base iron clad cut out HC type 415V, 100Aerected on polished wooden block. 216 Supplying and erecting porcelain base iron clad cut out HC type 415V, 200A erected on polished wooden block. 217 Supplyinganderectingiron work, sheet metal work consisting of CRCAsheets, varioussectionsofiron,plates, chequeredplates,rods,bars,MSpipes,etc. forpanel board or any other purpose with bending, cutting, drilling and welding completeerectedatthepositionwith necessarymaterialsdulypaintedwith one coat of red oxide and two coats of enamelpaint to match the switchgears or as per directions by the authority. 218 Supplying and erecting metal work in CRCA sheet including Iron work for supportswith fabrication ofboxes,panelboards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment andduly powder coated or paintedwith one coat of red lead paint and 2 coats of enamel paint complete. 219 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade& Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint,with suitable number of ways andwith SMC/DMC Insulators and accessories of suitable ratingcomplete as per specification no. CP-BB 220 Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V 200A having 25mm (Width) X 5 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade& Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint,with suitable number of ways andwith SMC/DMC Insulators and accessories of suitable ratingcomplete as per specification no. CP-BB 221 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core25 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 222 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 223 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core50 sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 224 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core70sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 225 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core95sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 226 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core120sq. mm. aluminiumconductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 227 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core4sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 228 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 229 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 230 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core16sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 231 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core25sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 232 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core35sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 233 Supplying, erecting & terminatingFR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 50sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 234 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wirearmoured (strip) cable 1100 V 2 core 4sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 235 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 236 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10sq. mm. aluminium conductor completeerected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipeas per specification no. CB-LT/AL 237 Supplying & erecting G.I. pipe‘A’ class 50 mmdia.erectedfor enclosingXLPEarmouredcable on wall/poleas per specification no. CB-CE 238 Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. 239 Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 90 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. 240 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mmoutside dia. double wall corrugatedpipes (DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete. 241 Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole/wallas per specification No. CB-SB 242 Supplying & erecting crimping type copper lugs for cable up to 16 sq mm completeas per specification No. CB-CL/CU 243 Supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm completeas per specification No. CB-CL/AL 244 Supplying & erecting crimping type aluminium lugs for cable25 sq mm completeas per specification No. CB-CL/AL 245 Supplying & erecting crimping type aluminium lugs for cable35 sq mm completeas per specification No. CB-CL/AL 246 Supplying & erecting crimping type aluminium lugs for cable50 sq mm completeas per specification No. CB-CL/AL 247 Supplying & erecting crimping type aluminium lugs for cable70 sq mm completeas per specification No. CB-CL/AL 248 Supplying & erecting crimping type aluminium lugs for cable95 sq mm completeas per specification No. CB-CL/AL 249 Providing & erecting 6 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 250 Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 251 Providing & erecting 8 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 135 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 252 Providing & erecting 9 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 155 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL 253 Providing & erecting 11 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 210 mm A/F, top 90 mm A/F on provided foundation as per specification no. OH-PL/OPL 254 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 255 Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT 256 Supplying and erecting 3 phase 5 core 16 sq.mm. (3x16+1x25+1x16) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 257 Supplying and erecting 3 phase 5 core 25 sq.mm.(3x25+1x25+1x16) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 258 Supplying and erecting 12 Way AB cable distribution box on provided pole with necessary accessories as per specification no. OH-ABC/JBS 259 Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results asper specification no. EA-EP 260 Providingpipetype earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rodcomplete with all materials testing and recording the results as per specification no. EA-EP 261 Supplying and erecting GI wire of high purity of required sizes used for earthing or any other purposes on wall with necessary G. I. Clamps fixed on wall/cable/ conduit with screws complete. 262 Carrying out Servicing of DG set from 62.5 kVA to 200 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water,Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC 263 Supplying & erecting Fully Automatic Star/delta starter suitable for12.5 H.P to 15 H.P. for 3 phase squirrel cage motor totally enclosed with overload and no volt relay complete erected on provided angle iron frame. 264 Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete. 265 Making trench in soft soil having 0.75 m depth and minimum0.3 m widthfor laying providedcables up to voltage level of 1.1kV complete As per specification No. CW-EXN-CTR 266 Making trench in Hard murum/Tar roadhaving 0.75 m depth and minimum0.3mtr width as per IS for laying provided cables up tovoltage level1.1Kv cable complete as per specification No. CW-EXN-CTR 267 PVC Insulation Tape 268 Supplying and erecting electronic type LED Strip for Outdoor LED Fittingsupto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 269 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 26W-45W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 270 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 46W-75W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 271 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 76W-100W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 272 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings 101W-150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 273 Supplying and erecting electronic type LED Strip for Outdoor LED Fittings151W-200W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 274 SUPPLY ofman power - electrician/wireman ( technician/lineman)for fault finding ,street light maintenance, garden maintenance, office maitenance, new light installation/replacement , mini Highmast light maintenanace.installation and replacing of street phase and underground cable, street light point on off 275 Supply ofman power - ( helper) for light chekerand tohelp technician/lineman
Contract Date: Jun 18, 2025 Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
16.
Public Administrative Department #7251402 AOC
Tender For Providing Electrical Material ,Erecting Electrical Work And Repairing Of Electrical Equipment Of Municipal Council Chalisgaon For Fy 2025-26-2 Supplying 1.5 Sq mm service wire Bundle (2CORE) 90 Mtr 3 Supplying 2.5 Sq mm service wire Bundle (2CORE) 90 Mtr 4 Supplying 4 Sq mm service wire Bundle (2CORE) 90 Mtr 5 Supplying 6 Sq mm service wire per (2CORE) 90 Mtr 6 Supplying 10 Sq mm service wire (2CORE) 90 Mtr 7 Supplying mains with 2x1.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WGMA/BW 8 Supplyin mains with 2x2.5 sq.mm F.R copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WGMA/BW 9 SupplyingPVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV 10 Supplying 6 to 32 A SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. 11 Supplying40A to 63A SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected. 12 Providing & erecting 3 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ tripalarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB 13 Supplying LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete 14 Supplying Fuse bridges with base HC type fuse links 240V 63A erected on polished wooden block complete 15 Supplying 4 pole power contactor 63 A with coil voltage of 220/240 V 16 Supplying 4 pole power contactor 80A-130A with coil voltage of 220/240 V 17 Supplying quartz electronic time switch having 24 hour dial to work on 250 V 50 cycle AC having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating upto 16A to use independently or in conjunction with contactor. 18 Supplying 12 V/150Ah tubular battery withbattery terminal wire, duly charged complete with 36 months warranty complete 19 Supplying & erecting 12 V 88 Ah heavy duty plate type Battery with terminal wire duly charged complete suitable for DG set with warrantee for 3 years 20 Supplying regular/ standard model ceiling fan of 1400mm. sweep complete erected in position as per specification no. FG-FN/CF 21 Providing bracket fan 400 mm. sweep A. C. 230volts 50 cycles 1350 R.P.M. Oscillating type, plastic or metal blades chrome plated guard with regulator and moisture proof treatment to winding and with ‘E’ class insulation. 22 Supplying fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner. 23 Supplying 10-12W, 230V integral type LED Lamp suitable for B-22/E-27 base. 24 MODE OF WORK - Supplying,erecting and comissioning part only 25 Supplying & erecting street light control panel in powder coated CRCA 14/16 SWG sheet, outdoor type, three phase, 415V consisted of suitable rating contactor, 24 hrs digital/ astronomical time switch with minimum 5 years battery backup, TPN MCB 63 A auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc for automatic operation & overcurrent, short circuit, earth fault protection of street lights upto themax load of 12 kW on provided iron frame / CC foundation complete. 26 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL 27 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL 28 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/ALL 29 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 30 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 6 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 31 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 32 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL 33 Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE(As per CSR 21-22 7-6-2) 34 Supplying and erecting Architectural pole of 4mtr height,pole placed with a aluminium/cast iron embellishment on the bottom & middle section for aesthetic & decorative purpose,pole shall have aluminium/cast iron casting on the base middle and on the joint giving it decorative look,the base aluminium/cast iron casting shall 148OD with aheight 180mm the casting will have ring on the top 20mm thickness,the middle Al/cast iron Casting shall be of conical design with bottom section of 145 OD having 3 ring of 15mm each. the conical casting shall taper for 145 OD on bottom to 92mm on top ,the pole with inbuilt junction box to fix 32 amp connectors & 6 amp MCB inside cut window of the bottom pipe with suitable size (as per attached Drawing)(Non DSR item ) 35 Supplying and Erecting attractive/decorative type of bracket with reducer/expander for holding decorative fixture on provided main pole having all the arrangement perpendicular to ground ,the bracket type is the double Arm Shall have span with 1000mm with in the middle made of 8 mm rod with flower leaf design (as per attached Drawing)(Non DSR item ) 36 Supplying and Erecting attractive/decorative type of bracket with reducer/expander for holding decorative fixture on provided main pole having all the arrangement perpendicular to ground ,the bracket type is the single Arm Shall have spanwith in the middle made of 8 mm rod with flower leaf design (as per attached Drawing)(Non DSR item ) 37 Supplying and Erecting of decorative luminaire made of Spun aluminium body with pressure die-cast heat management(PDCHM) and the IP optical Compartment with high power LED is comprised of deep drawn chemically polished and co-extruded thransformed polycarbonate protector stabilzed agent UV rays Suitable for 40-60 W LED fitting should be hangging type mounting decorative fixture with inbuilt Driver with efficiency >0.9 and having surge protection device of 10 KVA colour temperature 3000K/4000K/5700K natural day light LED,LED to be osaram/ Cree/Bridgelux & driver to be make with philips/Fulham/osaram(as per attached Drawing)(Non DSR item) 38 MakingM- 20 grade reinforced cement concretefoundation by considering the safe soil bearing capacity at site as 10 T/sq.mat 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).(As per CSR 21-22 16-3-9) 39 Supplying andlaying (including excavation of suitable width & depth up to 90 cm) 50 mmoutside dia. double wall corrugatedpipes(DWC) ofHDPE for enclosing cable below ground/road surface, to required depth complete(As per CSR 21-22 7-6-9). 40 Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rodcomplete with all materials as per specification no. EA-EP (As per CSR 21-22 9-1-4) 41 Supplying and erecting LED square / circular 5 to 8W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete. 42 Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for upto 4W-6W LED including driver and erecting by making necessary arrangement/recess in wall to make it flush with surface. 43 Supplying LED UP down light with aluminium body for indoor/outdoor application suitable for upto 4W-6W LED including driver and erecting by making necessary arrangement/recess in wall to make it flush with surface. 44 Supplying and erecting LED flexible strip light 5m length upto 25W conforming IP 65 of any colour with driver complete. 45 Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP. 46 MODE OF WORK - Repairing works only 47 Rewinding motor of the 1200/1400 mm ceiling fan and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc.Testing of fan for original speed and consumption with guarantee for one year. 48 Repairing of Generator focus lamp with Chock,connector coil Etc 49 Servising of Generator focus lamp 50 MODE OF WORK - Repairing and providing municipal council AC units 51 Providing servicing of 1/1.5/2/3 TR capacitysplit/window air conditioning unit complete with allnecessary material. Job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unit with blower, checking of electrical connection of indooras well as outdoor unit and submitting report to Engineer incharge. 52 Providing flushing out cooling coil and condensor coil of airconditioner unit refrigerant pipes internally with dry Nitrogen pressure in an approved manner 53 Providing brazing pipes and checking leakages in the split/ window unit duly with dry nitrogen pressure in an approved manner. 54 Providing replacement of existing unservicablerotary/scroll compressor of air conditioner 1.5 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 55 Providing replacement of existing unservicablerotary/scroll compressor of air conditioner 3 TR by new one of same capacity with guarantee for one year with provided refrigerant complete. 56 Providing replacement of unserviceable starting relay for AC unit. 57 Providing replacement of unserviceable starting/running capacitor for A/C unit. 58 Providing replacement of unserviceable fan motorcapacitor for A/C unit. 59 Providing replacement of unserviceable PCB for A/C unit upto 3 TR capacity. 60 Providing repair of of faulty PCB for air conditioning unit upto 3 TR capacity. 61 Supplying and installing of new fan motor for condenser for air conditioning unit 62 Supplying and installing of new fan motor for indoor unit of air conditioner up to 3 TR suitable to operate on 230V to 250V AC or 280V to 340V DC supply having 4 to 8 poles as per requirement. 63 Supplying and installing new fan blade outdoor unit for air conditioning unit. 64 Providing replacement of blower of indoor unit for air conditioning unit. 65 Providing replacement of remote of indoor unit for air conditioning unit. 66 Providing and fixing indoor plastic cabinet with all accessories 67 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 1.5TR window/split air conditioning unit. 68 Providing vaccumising the airconditioner system to 200 micron and charging with R-22 refrigerant for 3TR window/split air conditioning unit. 69 Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position asper specification no. APAC/ WAC 70 Providing servicing of 1/1.5/2/3 TR capacity split/window airconditioning unit with all necessary material. job includes checking of performance of unit, cleaning of filters of indoor unit, cleaning of outdoor unitwith blower, checking of electrical connection of indoor as well as outdoor unitcomplete and submitting report to Engineer incharge. 71 Providing annual comprehensive maintenance contract for 1.5TRsplit/window air conditioning unit complete as per terms and conditions. Jobincludes 1) quarterly servicing 2) on call repair 3) replacement of all spares within24 hours 4) sending standby manpower for VIP movement. The job exclude sheetmetal work and plastic material. 72 Supplying, installing, testing & commissioning cassette type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor room Air conditioning unit 2.5TR to 2.7TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32/R410A having copper condenser, dust filter, self diagnosis feature, stabilizer free operation, noise level maximum 50dBA at position as per specification no. APAC/ WAC 73 Supplying, installing, testing & commissioning cassette type room Air conditioning unit 3.4TR to 3.9TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noiselevel maximum 50dBA at position as per specification no. APAC/ WAC 74 Supplying, installing, testing & commissioning cassette type room Air conditioning unit 4TR to 4.4TR capacity with refrigerant R32/410A 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, minimum dust filter, noise level maximum 50dBA at position as per specification no. APAC/ WAC 75 MODE OF WORK - ELECTRICAL FITTING PART ONLY 76 Supplying and erecting PVC trunking (PVC casing-ncapping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON. 77 Supplying and erecting UPVC reinforced flexible conduit 31/32 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete. 78 Supplying and erecting HMS PVC conduit 32 mm dia. with PVC accessories on wall / ceiling as per specification No:WG-MA/CON. 79 Point wiring for independent plug in 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) FR grade copper wire, flush type switch, earthing and required accessories as perspecification No: WG-PW/SW 80 Wiring for plug on board with Switch socket, copper wiring and earthing as per specification No: WG-PW/SW 81 Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP 82 Point wiring in PVC trunking (casing-capping) with 1.5sq.mm (2+1E) FR grade copper wire, flush type switch,earthing and required accessories as per specification No: WGPW/SW 83 Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FR/ FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW 84 Supplying and erecting Ceiling rose / Batten holder /Slanting holder / hanging cord switch / hanging bell push/ pendent holder bakelite base 6A. erected on filled polypropylene board or polished double wooden block/ PVC junction box. 85 Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete. 86 Supplying and erecting flush type shockproof plug socket 6A & 16A (6 pin) with 16A switch combined with indicator lamp and fuse with gang box on wooden board. 87 Supplying and erecting PVC Surface modular switch box with double mounting plate for 6 modules duly erected. 88 Supplying and erecting PVC Surface modular switch box with double mounting plate for 13modules duly erected. 89 Supplying and erecting PVC Surface modular switch box with double mounting plate for 18 modules duly erected. 90 MODE OF WORK - Repairing and providing LED lights only 91 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 25W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. 92 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 26W-45W suitable to operate on 230V A.C. 50 Hz. having pf>0.95 and THD<10%. 93 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 46W-75W suitable to operate on 230V A.C.50 Hz. having pf>0.95 and THD<10%. 94 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 76W-100W suitable to operate on 230V A.C.50 Hz. having pf>0.95 and THD<10%. 95 Supplying and erecting electronic type Driver for Outdoor LED fittings upto 101W-150W suitable to operate on 230V A.C.50 Hz. having pf>0.95 and THD<10%. 96 Repairing for 18 to 45 W LED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 97 Repairing for 50 to 75 W LED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 98 Repairing for76 W to 100wLED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 99 Repairing for76 W to 150w LED flood light with SPD,Shouldering,cleaning etc complete with all required accessories 100 Repairing for 100 to 120 W flood light plate with al required accessories 101 providing for 100 to 120 W flood light plate with al required accessories 102 providing for 18w to 45 W flood light plate with al required accessories 103 providing for 46wto 75 W flood light plate with al required accessories 104 providing for76w to 90 W flood light plate with al required accessories 105 Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. 106 Supplying and erecting integrated LED flood light fitting Max. 70W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 8400 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2 107 Supplying and erecting integrated LED flood light fitting Max. 100W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 12000 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. 108 Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCTupto 6500K, THD<10%, p.f. >0.90, operating range of 140 270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2. 109 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ classG.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 110 Supplying and erecting integrated LED street light fitting 23 to 25W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 2300 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3Years warranty as per specification No FG-ODF/FLS2. 111 Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70,CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2. 112 MODE OF WORK - Shifting of highmast/RSJ/round pole 113 Dismentaling and Erecting upto20 m (clear height) motorized/non motorized high-mast on provided foundation with carefully dismentallation and erection of wire,luminaries etc complete 114 Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per designcomplete (upto 20 m raising lowering high mast) . 115 providing wire rope for raising lowering high mast 116 Providing luminaries ring for raising and lowering high mast 117 Supplying and erecting rolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ(for 8 mtr) 118 Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP 119 Painting of steel tubular / rail / RSJ pole above 6.0 length along with street light pole brackets, clamps etc by scrapping the existing paint complete as per specification no CW -PTG/PTP. 120 Supplying and erecting 3 phase 4 core 50 sq.mm. (3x50+1x35) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 121 Supplying and erecting 3 phase 4 core 35 sq.mm. (3x35+1x25) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 122 Supplying and erecting 3 phase 4 core 70 sq.mm. (3x70+1x50) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 123 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishingcomplete. (above 6 m to 9 m poles) 124 Making cement concrete foundation in 1:3:6 cement concrete, (20 to 25) mm. stone metal duly plastered with necessary curing for complete. (pole muffing or any other purpose). 125 MODE OF WORK - Extra-other accessories 126 Carrying out Servicing of DG set up to 50 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge.(Non Comprehensive) as per specification No. GEN-SER-AMC 127 Supplying and erecting static energy meter with 240V 50 Hz. AC supply 5 to 30 A, ISI mark, accuracy class 1.0 with backlit LCD display, (measuring and display kWh, kVAh, V,I,PF, frequency, kW, kVA, six months history of Energy & MD in kW & kVA) with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 128 Supplying and erecting static energy meter with 3 x 240V 50 Hz. AC supply 10 to 60 A, ISI mark, accuracy class 1.0 with backlit LCD display, (Measuring and display Trivector, V, I, kW, PF, Hz, Last month history of kWh and MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power & with transparent hinge type box complete erected on polished teak wood board duly wired with required size of weather proof PVC wires duly tested by electric supply company. 129 GOVERNMENT OF MAHARASHTRAPUBLIC WORKS DEPARTMENT(ELECTRICAL WING)CURRENT SCHEDULE OF RATES for 2022-2023(Note :- use of this item in critical conditionfor detail Refer DTN)
Contract Date: Apr 17, 2025 Contract Value : 10.28 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
17.
Civil Aviation #4112469 AOC
Bids Are Invited For Custom Bid For Services - Annual maintenance contract Of E And M Installations, ARMO of E&M Installations of DWR Building for IMD at DBAI Airport, Nagpur. SH: Operation & Maintenance of E&M Installations. (Year 2024-25), 1) General Scope of Work: - The Scope of work covers the following items: - a) Providing operation & maintenance services for following E & M installations at DWR Building, Nagpur Airport as per the attached Maintenance Schedules at Annexure-C. - 250 KVA Transformer - 1 No. - LT panels. - Internal Electrification installations of DWR building. - DG Set Operation. - Street lighting and perimeter road lighting. b) Providing day to day maintenance services, general cleaning of various installations as per Maintenance schedule specified. c) Minor repair & maintenance works and calibration of equipment etc. d) Any other installation as per instruction of Engineer-in-charge. e) Providing tools & plants and instruments as per the attached list. f) Maintenance of equipment / systems in satisfactory working conditions at all times during the contract period. g) The readings of voltage, power factor, current and other related parameters through various meters shall be checked and recorded in the LOG BOOK (provided by contractor) on hourly basis. Necessary action is to be taken by the contractor or his authorized representative if the readings are not normal. h) Attending complaints, trouble shooting and repairs & rectification action where needed. i) Replacement of spares for maintenance (preventive & breakdown) shall be provided by AAI, subject to availability at AAI stores. However, it is the responsibility of the contractor to intimate the EIC or his authorized representative if any spares are required for the breakdown maintenance of the system immediately after occurrence of fault and get their approval for procurement of spares. Nonavailability of spares will not be accepted as the reason for un-serviceability of the system. j) Routine maintenance like cleaning, inspection of machines / equipment / system, functional/serviceability checks etc. and maintaining records. k) Preventive & proactive maintenance as per AAI maintenance schedules in Annexure-C & OEM recommendations. l) Breakdown or un-serviceability of any of the electrical installations within the scope of this work should be recorded in the maintenance log-books by the deployed manpower of the contractor and the same shall be brought to the notice of EIC or his authorized representative immediately. Necessary identification & rectification of faults should be done and the system should be restored to normal operation. Spares required for rectification of faults shall be provided by AAI subject to availability in AAI stores, however in case of non-availability of spares the same shall be procured by the contractor after getting mandatory approval from the EIC and the proper GST tax invoice for such procurement of spares shall be submitted by agency for payment in the subsequent bills. Any lapse on the part of agency in carrying out the rectification of faults within the specified timeline shall be liable for penalty as per the conditions of the contract. m) Executing the works as per instructions of E-I-C and his/her authorized representative including daily reporting/ feedback and proper communication. n) Deputing manpower as mentioned in the contract at airport throughout the contract period on all days including Sundays & holidays with a mobile phone to receive complaints / instructions from AAI. However, one weekly off is applicable to each Wireman / Helper / Computer Operator. No reliever needs to be deputed on the weekly off of deputed manpower. Additional manpower to be deployed for all emergency works/ where needed, major breakdown etc. as per instruction of E-I-C. o) Providing minimum ‘site facilities’ as mentioned elsewhere in this contract. p) Abiding the contract conditions, norms/ rules & regulations of AAI, security guidelines, statutory bodies, labour laws enforced from time to time. q) Periodical review/ meetings by competent senior persons/proprietor. r) Order for executing repair and maintenance works within the scope of this contract shall be entered in the site order book or the maintenance log book, the contractor or his authorized signatory staff shall see the site order book and maintenance log books of various electrical installations every day and sign the same as a token of having received the order. s) Extra items, if any ordered shall be paid at market rates, for which the contractor shall produce the original purchase voucher / tax invoice which will be checked and verified by the Engineer-in-charge or his authorized representative to ensure its correctness. t) If the repair and maintenance work is to be carried out in the operational area, the contractor shall obtain necessary entry permits for all their employees as per existing BCAS norms. No work should be delayed for want of entry permit / passes. u) In case, the workmen deployed by the contractor are not able to rectify the faults or ensure smooth operation of the system as per the opinion of EIC, it is the responsibility of the contractor to deploy additional experienced manpower preferably from OEMs as recommended by the EIC at his own cost for necessary rectification. The contractor must abide by the instructions issued by the EIC in this regard and ensure the serviceability of system. v) Handing-over of the units/system in satisfactory working condition at the end of contract period by observing proper handing over procedures as per the instructions of E-I-C. w) Documentation. x) Comprehensive Maintenance contract of Ductable / Cassette / Split Type Air-Conditioners / Water-Cooler: The Scope of work includes following: - Comprehensive maintenance of Ductable / Cassette / Split Type Air-Conditioners as specified in SOQ, located at different areas, including providing & fixing all necessary consumables and spares such as replacement of faulty compressors, PCB cards, motors, insulating foam etc. - Comprehensive maintenance of 1 No. Water Cooler including providing & fixing all necessary consumables and spares such as replacement of faulty compressor, PCB etc. - Job includes monitoring for satisfactory working, periodical maintenance and all major & minor repairs of the Ductable / Cassette / Split type air conditioners and water coolers as and when required. It is clarified that these jobs are contingent /casual in nature. Registers shall be maintained for all the maintenance activities and submission to the Engineer In-Charge or his authorized representative as per maintenance schedule attached. - Supply and replacement of defective components like capacitors, relays, thermostats, fan blades, blowers, selector switches, air filters etc. including making suitable inter connections and rewiring of the unit etc. - Condenser / evaporator coil cleaning, leak testing, gas charging, replacement of capillary, oil charging etc. - Replacement of failed compressor with manufacturer repaired compressor / new compressor of similar model and make whenever required, including gas charging & all incidental works etc. Original documents like delivery challan and invoice from manufacturer or his authorized dealer indicating serial number of compressor shall be submitted to the Engineer-in-charge for approval before installing the compressor. - Any other work related to the proper maintenance specifically not mentioned herein. - Contractor shall depute sufficient / adequate number of skilled workmen to maintain all the air conditioners & water cooler in working condition including periodical observations repair and maintenance. - Record of all the works carried out and serviceability of the air conditioners and water cooler are to be maintained in the format prescribed by AAI. The register required for the record shall be supplied by the successful tenderer. - All the materials / components / cleaning material etc. what so ever required is included in the scope of work and shall be arranged by the contractor. - Contractor shall ensure the maintenance of all A/C units in a better physical appearance by cleaning of units, front grilles, fixing the front grille in the proper manner etc. - Contractor shall make the work site neat and clean after completing the work and no waste material or dust shall be left in the work site. - Contractor shall take over all the units under this contract within date of commencement of work, on as is where condition on award of the work. If any unit is not in working condition, due to defects related to compressor or due to component failure which will affect the performance of the unit, while taking over, the same shall be intimated in writing to the Engineer-in-Charge with details of defects and location etc. and get it acknowledged. - At the end of completion of contract, all the units shall be handed over to AAI in good working condition. - Contractor shall follow all labour laws applicable/enforced from time to time. Any violation of not following the labour laws shall be dealt with as per provision of agreement clauses. - Contractor has to obtain necessary entry pass / clearance if required from the AAI/BCAS for their workmen to work. It is the responsibility of the successful tenderer to fulfill all the formalities viz police verification etc. and bear the cost for photographs etc. for obtaining entry pass for their workmen. - Contractor shall be held responsible for any damage caused due to his negligence and has to make the same in good condition at its own cost. - Contractor has to arrange his own tools & plant required for the maintenance purpose for which nothing extra will be paid. - Minor complaints like replacement of capacitors, thermostats, relays, fault in wiring, filters etc. shall be attended immediately as per time period set by Engineer-In-Charge. If the contractor fails to attend within the time period given by the Engineer-In-Charge, the same shall be attended at the risk and cost of contractor. - Complaints like gas charging in Ductable / Cassette / Split A/C units or water cooler and gas leakages shall be attended and completed within two days from the date of occurrence of fault. Alternatively, spare serviceable units shall be provided by the contractor without any cost to AAI till the defective unit is made serviceable. - Failure to comply with two conditions mentioned above this para will attract a penalty of 5% of annual CMC rate of each unit per day of delay per A/C unit/water cooler and shall be deducted / recovered from the contractor. - Burnout compressor shall be repaired / replaced as applicable and the unit commissioned as per the time period set by Engineer-In-Charge. If contractor fails to attend, recovery shall be made at following rates: a) Equipment Room - Rs. 500 per day b) Offices. - Rs. 250 per day - A list of minimum activity schedule for the preventive maintenance is attached along with the special conditions. The activities shown are the minimum and hence, the contractor shall improve upon the same in their own interest, to ensure failure free units. - The tenderer shall quote their rates as per the Schedule of Quantities enclosed herewith. The awarded rates shall be firm throughout the contract period. - In case of any discrepancy between these special conditions and General Conditions of Contract, these special conditions will take precedence. y) Comprehensive Maintenance Contract of 1 No. 40 KVA UPS System (Make: Vertiv) through OEM / Authorized Dealer of OEM: The Scope of work includes following: - The scope of work includes scope of work as per UltraCare – Gold type of AMC services offered by M/s. Vertiv. - The contractor shall enter into a contract with OEM / Authorized Dealer of OEM after award of work and submit the details along with authorization details as required to the E-I-C. - Defective parts discovered during maintenance can either be repaired or replaced by new or as new parts. Spares replaced will be either of the same make or equivalent as per recommendation of OEM. - All necessary tools and instruments along with necessary skilled manpower required for the purpose of servicing the equipment shall be provided by contractor. - Preventive maintenance services with Quarterly Visits and breakdown services as applicable to ensure reliability and uptime of the system. - Guaranteed 2-hour on-site response, 7 days/week, 24 hours/day. - Includes all parts (Except Exclusions), labour, travel coverage & Unlimited Break Down calls. - Turn-around Time (TAT): For Minor Complaints - Avg. 6 Hrs after reporting at site UPS room e.g. Failure of Exhaust fans, Bleeder Resistors, Indicating Lamps, Display mismatch with actual value etc. For Major Complaints – Avg. 8 Hrs e.g. UPS failing to transfer to battery mode in the event of incoming power failure / Battery Breaker tripping due to battery failure / Battery Failure / UPS unable to transfer load on to the parallel UPS (Redundancy Failure) / UPS tripping on High temperature conditions / Control Card, major components failure such as IGBT’s, SCR’s & Wire wound Components within the UPS, Module Failure, Wire Harness damage. - PREVENTIVE MAINTENANCE SERVICE (Quarterly) • Cleaning up of Unit, Visual Inspection to check any deformation. • Checking and Adjustment (If needed) of Power parameters like input. Output, DC voltage & Current. • Checking and Adjustment (If needed) of Control parameters on different PCBs. • Tightness of all connections, if shut down possible. • Functional Checking up of Rectifier section. • Functional Checking up of Inverter section. • Functional Checking up of Static Switch Section. • With customer approval, perform operational test of the system including unit transfer and battery discharge. • Install or perform Engineering Field Change Notices (FCN) as necessary. a) Work to be performed during shifts as per instructions from EIC or his authorized representative. b) Cleaning of DG set & associated equipment. Maintenance of batteries, handling of fuel, attending genset non-starting problems. c) Attending electrical complaints like non-working of lights, fans, E & M equipment / systems, nonavailability of power supply, complaints of starters, wiring installations & any other abnormal conditions etc. d) Cleaning of Electrical & Mechanical Installations. e) Cleaning of premises & disposal of waste etc. after work. f) Keeping the work premises neat & clean. g) Maintaining proper earthing. h) Collecting spares/materials from stores etc where materials are supplied by AAI. i) Repairs at workshop where required. j) Temporary wiring works. k) Operation of E & M installations as and when required. l) Conservation of energy by switching off lights, fans, equipment etc when not needed, as per instructions of EIC or his/her authorized representative. m) Reporting the complaints / action taken etc to the concerned officials. n) Documentation like log book entries, accounting of dismantled materials / materials used in the work, complaint & preventive maintenance registers etc. o) Satisfactory overall maintenance of E&M installations Total Quantity :
Contract Date: Ref. Documents Contract Value : 17.25 Lakh
Boards / Undertakings / PSU No of Bidders 8
Maharashtra View Result →
18.
Public Administrative Department #3719959 AOC
Supply Of Electrical Materials For The Financial Year 2023-24 Under Chakan Nagar Parishad Electricity Department- 1 Supplying & Erecting Crimping Type Copper Lugs For Cable Up To 16 Sq. Mm. Complete As Per Specification No. 2 Supplying & Erecting Crimping Type Aluminium Lugs For Cable Up To 16 Sq. Mm. Complete As Per Specification No. Cb-Cl / Al 3 Supplying & Erecting Mains With 2X1.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wgma / Bw 4 Supplying And Erecting Mains With 2X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Anyother Places. As Per Specification No: Wg-Ma / Bw 5 Supplying, Erecting & Terminating Xlpe Armoured Cable 2 Core 6 Sq. Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No.Cb-Lt / Al ( 6 Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swgg.I. Binding Wire. 7 Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvc Insulated And Pvc Sheathed Wires On G.I. Bearer Wire No. 8 Swgcomplete Erected With Required Size Of Porcelain Reel Insulators And 16 Swg G.I. Binding Wire. 8 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 10 Sq. Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No.Cb-Lt / Al 9 Supplying, Erecting & Terminating Xlpe Armoured Cable 4 Core 16 Sq. Mm. Aluminium Conductor With Continuous 5.48 Sq. Mm. ( 12 Swg ) G.I. Earth Wire Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 10 Supplying And Erecting Ceiling Rose / Batten Holder / Slanting Holder / Hanging Cord Switch / Hanging Bell Push / Pendant Holder Bakelite Base 6A. Erected On Filled Polypropylene Board Or Polished Double Wooden Block / Pvc Junction Box 11 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 25Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 12 Supplying And Erecting Pvc Trunking ( Pvc Casing-N-Capping ) Of Size 32Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 13 Supplying And Erecting Hms Pvc Conduit Frls Grade 25 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 14 Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Classinsulation. 15 Supplying Pedestal Fan 400 Mm. 230 Volts 50 Cycles Oscillating Type Completewith Guard And Regulator 3 Meter. Of Flexible Wire And Hand Shield Type 3 Pin Plugtop. 16 Supplying And Erecting Exhaust Fan Heavy Duty 230 V A.C. 50 Cycles 375 / 380Mm. 1400 Rpm Complete Erected In Position As Per Specification No. Fg Fn / Exf 17 Supplying And Erecting Energy Saving Bldc Ceiling Fan 230 V A.C. 50 Cycles1200 Mm, Max. Energy Consumption Of 28W Having Service Ratio ( Cmm / W ) Of Min. 8 , Pf>0.9, Thd<10% With Ir Remote Control / Compatible Speedregulator, Temperature Rise Of Max. 40 Deg. C, Having External Mounted Controlpcb Completely Erected In Position As Per Specification No. Fg-Fn / Cf 18 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W 75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Th 19 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W 45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And T 20 Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. 21 Supplying & Erecting Inverter Led Batten 20W Tube Light Fitting With Polycarbonate Housing, Heat Sink, Integrated Hf Electronic Driver, Min. 2600Mah Lithium Ion Battery With Charging Time Of 8-10 Hours And Backup Time Of Min. 3 Hrs. With Minimum 25% Of Initial Watts Having Luminous Efficacy Of 100Lumen / Watt, Cri>80, Cct Of 6500K And Thd<=20% Having Useful Life Of Minimum 25000 Hrs. With Overheating Protection With 2 Years Warranty 22 Supplying And Erecting Anodized Aluminium Corridor / Passage Light Led Fitting ( 4 Feet ) Max. 22W With High Transitivity Diffuser With System Lumens Output Of Min.2200 Lumens , Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6000K, Beam Angle Of 110 Deg., Ripple<5%, Thd<10%, P.F. >0.95, Operating Range Of 200-270V, Surge Protection Of 2 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. 23 Supplying And Erecting Led Square / Circular Max. 18 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuserhaving System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of5%, Thd<10%, P.F. >0.95, Operating Range Of 120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. 24 Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 &Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Includingdriver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 25 Supplying & Erecting Integral Post Top Lantern Fixtures ( Light House Type ) Suitable Upto Led 18 W Lamp Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl 26 Supplying And Erecting Isi Mark Modular Type Switch 16A Dulyerected On Provided Plate And Box With Wiring Connectionscomplete. 1-8-2 27 Supplying And Erecting Modular Type 3 Pin 6 / 16A Multi Socket With Safetyshutter, Duly Erected On Provided Plate And Box With Wiring Connectionscomplete. 28 Supplying And Erecting Pvc Surface Modular Switch Box With Doublemounting Plate For 12 Module Duly Erected. 29 Supplying And Erecting Single Pole And Neutral Distribution Board ( Spndb ) , With 2 Ways For Incoming And 10 Ways ( 10 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb 30 Supplying And Erecting Programmable Digital Almanac Timer Microcontroller Based With Real Time Clock To Operate On Derived Switching ?On? & Switching ?Off? Street Light As Per Daily Sunsetand Sunrise Respectively Automatically Having 4 Digit Led Continuous Time Display, Relay Output 230 V / 10A With 10 Hrs Battery Backup And Manual Over Drive Facility Capable To Drive Different Capacitycontactors Timer Erected In Provided M.S. Box In An Approvedmanner. 31 Supplying And Erecting Four Pole Power Contactor 430 V, 40 A For Time Switch Complete Erected On Provided Wooden Block / Box, Withnecessary Materials 32 Supplying And Erecting Two Pole Power Contactor 230 V, 32 A For Time Switchcomplete Erected On Provided Wooden Block / Box, With Necessary Materials. 33 Supplying, Erecting & Marking Spmcb 6A To 32A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Swswr / Mcb 34 Supplying, Erecting & Marking Spmcb 40A To 63A, B- Series ( For Lighting ) In Provided Distribution Board As Per Specification No. Swswr / Mcb 35 Supplying And Erecting Cupboard For Enclosing Switchgears Or For Any Other Purpose Made From Selected Marine Plywood Planks 19 Mm Thick Duly Varnished / Painted From Inside And From Outside With Brass Hinges And Locking Arrangement With Suitable Lock With Keys In Duplicate. Cupboard Shall Be Dulygrouted With Suitable Size Of Iron Work In Wall At The Bottom. ( Size Of Cupboard Shall Be Specified In The Estimate ) 36 Epoxy Painting On Both Side Of Approved Colour Shade Of Provided Iron Work / Ms / Crca Sheet Steel Work Complete Along With Anti-Rust Treatment Complete. 37 Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mmdia. G.L. Rod Complete With All Materials As Per Specification No. 38 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100Aerected On Polished Wooden Block. 39 Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 63Aerected On Polished Wooden Block. 40 Supplying & Erecting Flat Flexible 3 Core 4 Sq.Mm Pvc Sheathed Submersibletype Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assemblycomplete. 41 Supplying & Erecting D.O.L Starter Suitable For 250 V, Single Phase 50 Cycleswith Overload Element With Necessary Materials And Connected To Supply Up To 3H.P. 42 Supplying & Erecting Automatic Control Panel For 3 Ph, 415 Volt, A.C.Submersible / Centrifugal Pump Set Up To 7.5 Hp - 10 H.P. Consisting Of Dolstarter Having Relay Range 13-21 Amp, S.P.P., Combined Ammeter / Voltmeter, Phase Indicating Lamp Enclosed In Crca Powder Coated Vibration Proof Enclosure With Ip 54 Protection. Control Panel Should Offer Single Phasing, Phasereversal, Phase Imbalance Etc. 43 Supplying & Erecting Minimum Three & Above Star Rated Centrifugal Water Pump ( Monoblock ) , 230V, Single Phase 50 Cycles A.C. Supply Of 1.125Kw / 1.5Hp With Discharge 198 / 50 Litres Per Minute ( Lpm ) ) For Head Of 15 / 37.5 M & 40 Mm Suction / 32 Mm Delivery Pipe On Provided C.C.Foundation As Per Specification No. Wp-Cgp 44 Providing Annual Comprehensive Maintenance Contract For 1.5Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Jobincludes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheetmetal Work And Plastic Material. 45 Carrying Out Servicing Of Dg Set Up To 50 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins On Load. Checking Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Ofradiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internally Using Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Perspecification No. Gen-Ser-Amc 46 Providing Vehicle Mountedhydraulic Ladder On Hour Basis With Transportation , Fuel And Driver Operator 47 Providing Electrical Grinder Machine With Wheel / Disc For Cutting Wood , Metal, Brick Etc 48 Electric Drill Machine With Tool Kit 49 Mnx 9-40Amp Contactor Operating Coil 50 Mnx 50-80Amp Contactor Operating Coil 51 Supplying And Erecting 1 Phase 2 Core 16 Sq.Mm. ( 1X16+1X25 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 52 Foundation Plate, Bolt As Per Requirement 53 Painting Of Steel Tubular / Rail / Rsj Pole Above 6.0 M Length Along Withstreet Light Pole Brackets, Clamps Etc By Scrapping The Existing Paint Completeas Per Specification No Cw -Ptg / Ptp. 54 Providing Pair Of Duly Tested Rubber Hand Gloves As Per Is :47705 Suitable For Working Up To 22 Kv Supply Complete. 55 Supplying Standard First Aid Box With Necessary Antiseptic Cream, Medicine Foruse On Wounds Due Burn, Crepe Bandage, Gauge Bandage, Medicated Ready To Usebandage ( Band-Aid ) Adhesive Tape For Medicinal Use, Scissors, Anti-Septic Solution, Etc. ( All Above Contents Shall Be Of Standard Makes ) 56 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cmdeep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishingcomplete. ( Above 6 M To 9 M Poles ) 57 Making Cement Concrete Foundation In 1:3:6 Cement Concrete, ( 20 To 25 ) Mm.Stone Metal Duly Plastered With Necessary Curing For Complete. ( Pole Muffing Orany Other Purpose ) . 58 Providing, Commissioning And Maintaining Additional Ip Based 2.0 Mp, Full Hd, Ir Ip Ptz Camera In Existing Cctv System With Necessary Mains, Switchgears On Hire Basis For One Day. 59 Providing Temporary Illumination Consisting Of Flood Light Fitting 200 W Complete Led Fitting With Lamp, Complete Required Switchgear Erected And Dismantled Without Using Scaffolding Upto Three Days. 60 Providing And Maintaining Temporary Cordless ( Hand Type Or Lape Type ) Super Sensitive Huf Microphone ( 1 No Stand By ) For One Day. 61 Providing, Maintaining And Operating Temporarypublic Address System On Hire Consisting 02 Nos. Solid State Heavy Wattage Amplifier 250 Watts ( One For Working And Another For Stand By Emergency ) Working On Ac / Generator And 24 Volt Car Battery Supply, 06 Nos. Of Matching Of 100 Volt Line ( 200 Watts ) Box Type Speakers / Sound Column, 02 Nos Super Sensitive Microphone With Suitable Size Of Microphone Holding Stand.The System Shall Be In A Fully Automatic Change Over Operation In Case Of Failure Of Supply For One Day. 62 Hiring Charges For Supplyingand Maintaining 230V, 50 Cycles Ac Generatingset1 To 2 Kva Capacity With Necessaryfuel, Mains, Switchgears And Accessories Complete With Continuousrunning Onload / No Load As Per Requirements Completewith Self Certification. 63 Hiring Charges For Supplyingand Maintaining 230 / 415 V, 50 Cycles Acgenerating Set3 To 10 Kvacapacity With Necessaryfuel, Mains, Switchgears And Accessories Complete With Continuousrunning Onload / No Load As Per Requirements Completewith Self Certification. 64 Hiring Charges For Supplyingand Maintainingtemporary415v, 50Cyclesacgenerating Set 11 To 25 Kva ( Excluding 25 Kva ) Capacity With Necessaryfuel, Mains, Switchgears And Accessories Complete With Continuousrunning Onload / No Load As Per Requirements Completewith Self Certification. 65 Providing Temporary Illumination Consisting Of White / Colour Series Lights 50 Nos. With Miniaturelampsof 6.2 To 16V With Required Switchgears Erected And Dismantled With Rotor Effect As Approved Without Scaffolding Upto Three Days. 66 Providing Temporary Illumination Consisting Of Led Rope Light Having 2 To 5 W Capacity Per Meter And Consisting Suitable Power Adaptor With Mains, Switchgears Erected And Dismantled With Using Scaffolding And Maintaining The Same Upto 3 Days
Contract Date: Mar 15, 2024 Contract Value : 50.00 Lakh
Local Bodies No of Bidders 3
Maharashtra View Result →
19.
Public Administrative Department #3510915 AOC
Tender For Annual Tender Of Electric Maintenance And Labour Supply, Test , Supplying And Erecting Pvc Trunking ( Pvccasing-N-Capping ) Ofsize25 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. , Supplying And Erecting Pvc Trunking ( Pvccasing-N-Capping ) Ofsize32 Mm With Accessorieson Wall / Ceiling As Per Specification No: Wg-Ma / Con. , Supplying And Erecting Mains With 2X1.5 Sq.Mm Frlshcopperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 1X1.5 Sq.Mm Frlshcopperpvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 2X2.5 Sq.Mmfrlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 1X2.5 Sq.Mmfrlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 2X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 1X4 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 3X2.5 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Mains With 4X16 Sq.Mm Frlsh Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wg-Ma / Bw , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 1.5 Sq.Mm ( 30 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Strandedcopper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Pvc Insulated Pvc Round Sheathed 2.5 Sq.Mm ( 50 No. X 0.25 Mm Dia. ) 3 Core Flexible Multi Strandedcopper Industrial Cable For Voltage Grade Up To 1.1 Kv , Supplying And Erecting Mains With Wp 2 X 2.5 Sq. Mm. 1100 V Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 2 X 4 Sq. Mm. 1100 V Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains With Wp 2 X 6 Sq. Mm. 1100 V. Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains Withwp 3 X 4 Sq. Mm. 1100 V. Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erecting Mains Withwp 3 X 6 Sq. Mm.1100 V. Grade Aluminium Pvcinsulatedandpvc Sheathed Wires On G.I. Bearer Wire No. 8 Swg Complete Erectedwith Required Size Ofporcelainreelinsulators And 16 Swg G.I. Binding Wire. , Supplying And Erectingmodular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Switch 16Aduly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Bell-Push 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Bell-Push With Indicator 2 Modules 6A / 10A, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Modular Type Two Way Switch 6A / 10A ( 2 Module ) , Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Switch 16 / 20 Awith Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type Switch One Way 16 / 20 A, Duly Erected On Provided Plate And Box With Wiring Connections Complete With Neon Indicator. , Supplying And Erectingmodular Type D.P. Switch 32A With Indicator, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type 3 Pin 6Amultisocket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type 3 Pin 6 / 16Amultisocket With Safety Shutter, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erectingmodular Type ( Two Module ) Electronic Step Regulator For Fan, Duly Erected On Provided Plate And Box With Wiring Connections Complete. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 1 Module Complete Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 2Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 3Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 4 Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting & Front Plate For 8 Module Complete Duly Connected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 12Module Duly Erected. , Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 16 / 18 Module Duly Erected. , Point Wiring For Ceiling Fan In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthingand Required Accessories As Per Specification No: Wg-Pw / Sw , Point Wiring For Independent Plug In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Frlsh Grade Copper Wire, Modular Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw , Wiring For Plug On Board Withswitch Socket Surface / Concealed Type, Copper Wiring And Earthing And With Modular Accessories As Per Specification No: Wg-Pw / Cw , Supplying And Erectingled Square / Circular Max. 18 W Down Lighter / Panel Light Having Pressure Die-Cast Aluminium Housing, Polystyrene Diffuser Having System Lumens Output Of Min. 2000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. , Supplying And Erectingrectangular Shaped Ledpanel Light ( 1200Mm X 300Mm ) Max. 35 Whaving Crca Powder Coated Housing, Polystyrene Diffuser Havingsystem Lumens Output Of Min. 4200 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Max. Ripple Of 5%, Thd<10%, P.F. >0.95, Operating Range Of120-270V, Surge Protection Of 2.5 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, Having Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips Complete With 3 Years Warranty. , Supplying And Erectingbulk Head Led Fittingmax. 10Wwith High Transitivity Diffuser Withsystem Lumens Output Of Min. 1100 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>80, Cct Upto 6500K, Beam Angle Of 120 Deg., Thd<10%, P.F. >0.95, Operating Range Of140-260V, In Built Surge Protection Of 2.5 Kv, Life Class Of50, 000 Hrs. At L70b50, Including Driver, Ip66, Ik09 Rated On Provided Pvc Block / Wooden Board With 3 Years Warranty. , Supplying And Erecting Anodized Aluminium Corridor / Passage Light Led Fitting ( 4 Feet ) Max. 22Wwith High Transitivity Diffuser Withsystem Lumens Output Ofmin.2200 Lumens , Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6000K, Beam Angle Of 110 Deg., Ripple<5%, Thd<10%, P.F. >0.95, Operating Range Of200-270V, Surge Protection Of 2 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver, With End Caps On Provided Pvc Block / Wooden Board With 3 Years Warranty. , Supplying And Erecting Condenser 4 Microfarad For Fluo. Fitting As Per Specification No Fg-Fg / As7. , Supplying And Erecting Integrated Led Street Light Fitting18 To 22W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 1800 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 23 To 25W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 2300 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting26 To 30W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing , Having System Lumens Output Of Min. 2600 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 40 To 50W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 4400 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 60W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 6600 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 85-90W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 9300 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integratedled Street Light Fitting 100-110W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 11000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 120W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 13000 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 130-140W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 15600 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Street Light Fitting 160-170W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 19000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 30W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 3000 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 50W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 5000 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 120W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min.14500 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 155W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 18600 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Flood Light Fitting Max. 195W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Havingsystem Lumens Output Of Min. 23400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification Nofg-Odf / Fls2. , Supplying And Erecting Integrated Led Post Top45w Ip65 & Ik10 Class Having Die Cast Aluminium Housing With Uv Protected Polycarbonate Diffuser, Having System Lumens Output Of Min.4500 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>80, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of140-240V, Inbuilt Surge Protection Of 2 Kv, Life Class Of 30, 000 Hrs. At L50b50 , Including Driver Complete With 2 Year Warranty As Per Specification Nofg-Odf / Fls2. , Erecting The Departmentally Supplied Wp Led Street Light / Flood Light Fitting Upto 80W. , Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above 80 To 150W . , Erecting Departmentally Supplied Led Street Light / Flood Light Fitting Above 150 To 400W . , Supplying And Erecting Gate / Garden Light Fitting With 200Mm Dia. Glass Bowl Suitable For Upto 12W Led Lampon Provided Pipe As Per Specification No. Fg-Odf / Glt , Supplying And Erecting Gate / Garden Light Fitting With 300Mm Dia. Glass Bowl Suitable For Upto 12W Led Lamp On Provided Pipe As Per Specification No. Fg-Odf / Glt , Supplying & Erecting Integral Post Top Lantern Fixtures ( Mushroom Type ) Suitable For Led Lamp Upto 12 W Consisting Of Clear Acrylic Top Cover, Cast Aluminium Pole Cap Complete With Accessories On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl , Supplying & Erecting Integral Post Top Lantern Fixtures ( Globe Type ) Suitable For Led Lamp Upto 12 W Consisting Of Aesthetic Round Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl , Supplying & Erecting Integral Post Top Lantern Fixtures ( Light House Type ) Suitable Upto Led 18 W Lamp Consisting Of Combination Of Spun Aluminium Canopy & Clear Acrylic Top Cover, Cast Aluminium Pole Cap On Provided Pole / Bracket As Per Specification No. Fg-Odf / Ptl , Supplying And Erecting Street Light Bracket For Erection Of Single Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt / Bpc , Supplying And Erecting Street Light Bracket For Erection Of Double Fitting Made From 40 Mm. Dia ‘B’ Class G.I. Pipe 1.0 M. In Length Along With Pole Cap Of 300 Mm Length 100 Mm Dia Duly Welded As Per Specification No. Fg-Bkt / Bpc , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittingsupto 25W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings151w-200W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying & Erecting 0.5W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying And Erecting Pigmy / Candle Lamp Miniature Type Coloured / White. , Supplying & Erecting 3W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting 5W-7W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting 10-12W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting 14W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying & Erecting18w, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. , Supplying And Erecting Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 Rpm. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Speed Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation. , Supplying And Erecting Exhaust Fan Medium Duty 230 V A.C. 50 Cycles 225 Mm. 1400 Rpm With Condenser Complete Erected In Position With Necessary Materials. Fan Motor With Moisture Proof Treatment And ‘E’ Class Insulation. , Supplying And Erectingenergy Saving Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm Complete Erected In Position As Per Specification No. Fg-Fn / Cf , Supplying And Erecting Energy Saving Bldc Ceiling Fan 230 V A.C. 50 Cycles 1200 Mm, Max. Energy Consumption Of28w Having Service Ratio ( Cmm / W ) Of Min. 8 , Pf>0.9, Thd<10% With Ir Remote Control / Compatible Speed Regulator, Temperature Rise Of Max. 40 Deg. C, Having External Mounted Control Pcb Completely Erected In Position As Per Specification No. Fg-Fn / Cf , Supplying And Erecting Condenser 2.5 Micro Farad For Ceiling Fan , Erection Ofdepartmentallysupplied Ceiling Fan With Necessary Materials Complete. , Erectionofdepartmentallysupplied Exhaust Fan With Necessary Materials Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 12Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigeranthaving 22Swg Thickness And Inner Dia / Size 16Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 22Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 32Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 35Mm Complete. , Supplying & Erecting Seamless Outside & Inside, Smooth, Dry And Clean Copper Pipe With Rohs Compliant Suitable For Refrigerant Having 22Swg Thickness And Inner Dia / Size 42Mm Complete. , Providingservicing Of 1 / 1.5 / 2 / 3 Tr Capacity Split / Window Air Conditioning Unit With All Necessary Material. Job Includes Checking Of Performance Of Unit, Cleaning Of Filters Of Indoor Unit, Cleaning Of Outdoor Unit With Blower, Checking Of Electrical Connection Of Indoor As Well As Outdoor Unit Complete And Submitting Report To Engineer Incharge. , Providing Annual Comprehensive Maintenance Contract For 1 Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Excludes Sheet Metal Work And Plastic Material. , Providing Annual Comprehensive Maintenance Contract For 1.5Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material. , Providing Annual Comprehensive Maintenance Contract For 2Tr Split / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material. , Providing Annual Comprehensive Maintenance Contract For 3Tr To 4.5Trsplit / Tower / Window Air Conditioning Unit Complete As Per Terms And Conditions. Job Includes 1 ) Quarterly Servicing 2 ) On Call Repair 3 ) Replacement Of All Spares Within 24 Hours 4 ) Sending Standby Manpower For Vip Movement. The Job Exclude Sheet Metal Work And Plastic Material , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 1Trby New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 1.5Tr By New One Of Same Capacitywith Guarantee For One Year With Provided Refrigerant Complete. , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 2Tr By New One Of Same Capacitywith Guarantee For One Year With Provided Refrigerant Complete. , Providing Replacement Of Existing Unserviceable Rotary / Scroll Compressor Of Air Conditioner 2.5Tr To 4.5Tr By New One Of Same Capacitywith Guarantee For One Year With Provided Refrigerant Complete. , Providing Flushing Out Cooling Coil And Condenser Coil Of Airconditioner Unit Refrigerant Pipes Internally With Dry Nitrogen Pressure, Complete. , Providing Brazing Pipes And Checking Leakages In The Split / Window Unit Duly With Dry Nitrogen Pressure, Complete. , Providing Replacement Of Unserviceable Starting Relay For Ac Unit. , Providing Replacement Of Unserviceable Starting Capacitor For Ac Unit. , Providing Replacement Of Unserviceable Running Capacitor For Ac Unit. , Providing Replacement Of Unserviceable Fan Motor Capacitor For Ac Unit. , Providing Replacement Of Unserviceable Pcb For Ac Unit Upto 3Tr Capacity. , Providing Repair Of Faulty Pcb For Ac Unit Upto 3Tr Capacity. , Supplying And Installing Of New Fan Motor For Condenser For Air Conditioning Unit , Supplying And Installing Of New Fan Motor For Indoor Unit Of Air Conditioner Up To 3Trsuitable To Operate On 230 / 250V, A.C. Or 280-340V Dc Supply Having 4 To 8 Poles As Per Requirement. , Supplying And Installing New Fan Blade Outdoor Unit For Ac Unit. , Providing Replacement Of Blower Of Indoor Unit For Ac Unit. , Providing Replacement Of Remote Of Indoor Unit For Ac Unit. , Providing Vaccumising The Airconditioner System And Charging With Refrigerant R32 For Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 For Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 For 1Tr Window / Split Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With R32 Refrigerant For 1.5Tr Window / Split Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 For 2Tr Window / Split Ac Unit. , Providing Vaccumising The Airconditioner System To 200 Micron And Charging With Refrigerant R32 Refrigerantfor 3Tr Window / Split Ac Unit. , Providing Replacement Of Existingunserviceablecompressor Of 40 Litre Cooling Capacity Water Cooler By New One Of Same Capacity Along With Suitable Refrigerant With Guarantee For One Year. , Providing Replacement Of Existingunserviceablecompressor Of 60 Litre Cooling Capacity Water Cooler By New One Of Same Capacity Along With Suitable Refrigerant With Guarantee For One Year. , Providing Replacement Of Existing Unserviceable Compressor Of 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity Along With Suitable Refrigerant With Guarantee For One Year. , Providing Replacement Of Existingunserviceable Condenser Coil Of 40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Providing Replacement Of Existing Unserviceable Ss Water Tap Of 40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Providing Replacement Of Existingunserviceable Relay40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Providing Replacement Of Existingunserviceablethermostat Of 40 / 80 / 150 Litre Cooling Capacity Water Cooler By New One Of Same Capacity, Testing To The Satisfaction Of Site Engineer For Cooling And Along With Guarantee For One Year With Suitable Refrigerant. , Supplying And Erecting Candle Filter With Filter Pot For Water Cooler. , Supplying And Erecting Connector Pipe For Candle Filter Of Water Cooler. , Providing Replacement Of Base Tray Of Water Cooler Of Any Capacity. , Supplying And Erecting Quartz Electronic Timeswitchhaving 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeablenickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Up To 16A To Use Independently Or In Conjunction With Contactor. , Supplying And Erecting Two Pole Power Contactor 230 V, 32 A For Time Switch Complete Erected On Provided Wooden Block / Box, With Necessary Materials. , Supplying And Erectingfour Pole Power Contactor 430 V, 16 Afor Time Switch Complete Erected On Provided Wooden Block / Box, With Necessary Materials. , Supplying And Erectingfour Pole Power Contactor 430 V, 40 Afor Time Switch Complete Erected On Provided Wooden Block / Box, With Necessary Materials. , Supplying &Erecting Four Poleon Load Changeover Switch, 415V, 100A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Rotary Handle, Operational Current Category Ac23a Complying To Is / Iec 60947-3 Part-1 / 3. , Supplying &Erecting Four Poleon Load Changeover Switch, 415V, 200A, Open Execution Having Staggered Termination, Phase Barrier, Shroud Termination And Terminal Cover Along With Auxiliary Contacts And Ready To Upgrade With Fuse Protection Kit, Operational Current Category Ac23a Complying To Is / Iec 60947-3 Part-1 / 3. , Supplying, Erecting & Marking Spmcb 0.5A To 5A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Kain Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 6A To 32A, C-Serieswith Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 6A To 32A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Spmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 6A To 32A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 6 A To 32 A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 40A To 63A, C-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Dpmcb 40A To 63A, B-Series With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Tpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Tpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Fpmcb 6A To 32A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka In Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erecting & Marking Fpmcb 40A To 63A, With Rated Short - Circuit Breaking Capacity ( Icn ) 10Kain Provided Distribution Board As Per Specification No. Sw-Swr / Mcb , Supplying, Erectingand Marking Double Pole Isolator Only Switch Version Of Miniature Circuit Breakerof40awith Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erectingand Marking Triplepoleisolatorsonlyswitch Versionofminiaturecircuitbreaker Of 40A With Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erecting And Markingtriple Pole Isolators Only Switch Version Of Miniature Circuit Breaker Of 63Awith Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erecting And Markingtriple Pole Isolators Only Switch Version Of Miniature Circuit Breaker Of 100Awith Required Wiring Connections And Lugs Etc. In Provided Distribution Board. , Supplying, Erecting And Markingfour Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 40A In Provided Distribution Board. , Supplying, Erecting And Markingfour Pole Isolators Only Switch Version Of Miniature Circuit Breakers Of 63Ain Provided Distribution Board. , Supplyingand Erecting Single Pole And Neutral Distributionboard ( Spndb ) , With 2 Ways For Incoming And 2 Ways ( 2 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb , Supplyingand Erecting Single Pole And Neutral Distributionboard ( Spndb ) , With 2 Ways For Incoming And 6 Ways ( 6 Poles ) For Outgoing Sp Mcbs, With Door, 1.2Mm Thickness Surface / Flush Mounted, Ip 43 Protection On Iron / Gi Frame As Per Specification No. Sw-Swr / Mcbdb , Supplying & Erecting Crca Sheet Metal Enclosures Of 1.2Mm Thickness With 20A, 2 Pin Plug & Earth Socket And 20A, 3 Pin Plugtop With 20A / 30A Single Pole Mcb Having Rated Short - Circuit Breaking Capacity ( Icn ) 10Ka Complete Erected On Angle Iron / Gi Frame. , Supplying & Erecting Crca Sheet Metal One Way Enclosures Of 1.2Mm Thickness Suitable For Dp Mcb / Tp Mcb / Fp Mcb / Rccb / Rcbo Complete Erected On Angle Iron / Gi Frame. , Providing & Erecting 4 Pole Mccb, 415 V, 100A, Rated Short-Circuit Breaking Capacity 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact.Mccb With Phase Barriers On Both Sides, Insulation Withstand Capacity 800V, No Line-Load Bias In Provided Enclosure / Panel As Per Specification No. Sw-Swr / Mccb , Supplying, Erecting & Commissioning 2 Pole Rccb 63A, Electromagnetictype With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Complete As Per Specification No. Sw-Rccb / Rccb , Supplying, Erecting & Commissioning 4 Pole Rccb 63A, Electromagnetic Type With 30 / 100 / 300 Ma Sensitivity With Earth Leakage Trip Indication Completeas Per Specification No. Sw-Rccb / Rccb , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 16A Erected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 32Aerected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 63Aerected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 100Aerected On Polished Wooden Block. , Supplying And Erecting Porcelain Base Iron Clad Cut Out Hc Type 415V, 200A Erected On Polished Wooden Block. , Supplyinganderectingiron Work, Sheet Metal Work Consisting Of Crcasheets, Varioussectionsofiron, Plates, Chequeredplates, Rods, Bars, Mspipes, Etc. Forpanel Board Or Any Other Purpose With Bending, Cutting, Drilling And Welding Completeerectedatthepositionwith Necessarymaterialsdulypaintedwith One Coat Of Red Oxide And Two Coats Of Enamelpaint To Match The Switchgears Or As Per Directions By The Authority. , Supplying And Erecting Metal Work In Crca Sheet Including Iron Work For Supportswith Fabrication Ofboxes, Panelboards, Etc. Including Cutting, Bending, Drilling, Welding, Riveting, Treated With Anti-Rust Treatment Andduly Powder Coated Or Paintedwith One Coat Of Red Lead Paint And 2 Coats Of Enamel Paint Complete. , Supplying And Erecting Bus Bar Chamber Triple Pole With Neutral With Four Aluminium Bars, 500V, 100A Having 15Mm ( Width ) X 3 Mm ( Thickness ) , With 99.9 % Aluminium Purity As Per E91e Grade& Current Density 0.8 A Per Sq. Mm. Compliance To Is 5082 And Enclosure Fabricated With 16 Swg Crca Sheet And Epoxy Paint, With Suitable Number Of Ways Andwith Smc / Dmc Insulators And Accessories Of Suitable Ratingcomplete As Per Specification No. Cp-Bb , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core25 Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core35sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core50 Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core70sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core95sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 3½ Core120sq. Mm. Aluminiumconductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core4sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core6sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core10sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core16sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core25sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminatingfr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core35sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wirearmoured ( Strip ) Cable 1100 V 2 Core 4Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 6Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 10Sq. Mm. Aluminium Conductor Completeerected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipeas Per Specification No. Cb-Lt / Al , Supplying & Erecting G.I. Pipe‘A’ Class 50 Mmdia.Erectedfor Enclosingxlpearmouredcable On Wall / Poleas Per Specification No. Cb-Ce , Supplying Andlaying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mmoutside Dia. Double Wall Corrugatedpipes ( Dwc ) Ofhdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete. , Supplying & Erecting Frp Box Of Size 250Mm X 200Mm X 100 Mm, 2.7 Mm Thick Complete On Pole / Wallas Per Specification No. Cb-Sb , Supplying & Erecting Crimping Type Copper Lugs For Cable Up To 16 Sq Mm Completeas Per Specification No. Cb-Cl / Cu , Supplying & Erecting Crimping Type Aluminium Lugs For Cable Up To 16 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable25 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable35 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable50 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable70 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying & Erecting Crimping Type Aluminium Lugs For Cable95 Sq Mm Completeas Per Specification No. Cb-Cl / Al , Supplying And Erecting 3 Phase 5 Core 16 Sq.Mm. ( 3X16+1X25+1X16 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc , Supplying And Erecting 3 Phase 5 Core 25 Sq.Mm. ( 3X25+1X25+1X16 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc , Supplying And Erecting 12 Way Ab Cable Distribution Box On Provided Pole With Necessary Accessories As Per Specification No. Oh-Abc / Jbs , Providng Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results Asper Specification No. Ea-Ep , Providingpipetype Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Dia. G.I. Rodcomplete With All Materials Testing And Recording The Results As Per Specification No. Ea-Ep , Carrying Out Servicing Of Dg Set From 62.5 Kva To 200 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins Checking For Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Of Radiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internally Using Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Per Specification No. Gen-Ser-Amc , Supplying & Erecting Fully Automatic Star / Delta Starter Suitable For12.5 H.P To 15 H.P. For 3 Phase Squirrel Cage Motor Totally Enclosed With Overload And No Volt Relay Complete Erected On Provided Angle Iron Frame. , Supplying & Erecting Flat Flexible 3 Core 4 Sq.Mm Pvc Sheathed Submersible Type Copper Cable Suitably Clamped At Fixed Intervals With Column Pipe Assembly Complete. , Making Trench In Soft Soil Having 0.75 M Depth And Minimum0.3 M Widthfor Laying Providedcables Up To Voltage Level Of 1.1Kv Complete As Per Specification No. Cw-Exn-Ctr , Making Trench In Hard Murum / Tar Roadhaving 0.75 M Depth And Minimum0.3Mtr Width As Per Is For Laying Provided Cables Up Tovoltage Level1.1Kv Cable Complete As Per Specification No. Cw-Exn-Ctr , Pvc Insulation Tape , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittingsupto 25W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 46W-75W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 76W-100W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings 101W-150W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supplying And Erecting Electronic Type Led Strip For Outdoor Led Fittings151w-200W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. , Supply Ofman Power - Electrician / Wireman ( Technician / Lineman ) For Fault Finding , Street Light Maintenance, Garden Maintenance, Office Maitenance, New Light Installation / Replacement , Mini Highmast Light Maintenanace.Installation And Replacing Of Street Phase And Underground Cable, Street Light Point On Off , Supply Ofman Power - ( Helper ) For Light Chekerand Tohelp Technician / Lineman
Contract Date: Mar 06, 2024 Contract Value : Ref. Document
Local Bodies No of Bidders 3
Maharashtra View Result →
20.
Housing Urban and Rular Development #3373124 AOC
Tender For Maintenance Of Panampilly Nagar Office Complex- Guest House-1 Guest House Civil Works 2 15.2.2 : Demolishing Cement Concrete Manually / By Mechanical Means Including Disposal Of Material Within 50 Metres Lead As Per Direction Of Engineer - In-Charge.Nominal Concrete 1:4:8 Leaner Mix ( Including Equivalent Design Mix ) 3 15.23.1 : Dismantling Tile Work In Floors And Roofs Laid In Cement Mortar Including Stacking Material Within 50 Metres Lead.For Thickness Of Tiles 10 Mm To 25 Mm 4 15.56 : Dismantling Old Plaster Or Skirting Raking Out Joints And Cleaning The Surface For Plaster Including Disposal Of Rubbish To The Dumping Ground Within 50 Metres Lead. 5 13.7.1 : 12 Mm Cement Plaster Finished With A Floating Coat Of Neat Cement Of Mix:1:3 ( 1 Cement : 3 Fine Sand ) 6 15.12.1 : Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking Within 50 Metres Lead:Of Area 3 Sq. Metres And Below 7 15.12.2 : Of Area Beyond 3 Sq. Metres 8 13.18 : Neat Cement Punning 9 4.2.2 : Providing And Laying Cement Concrete In Retaining Walls, Return Walls, Walls ( Any Thickness ) Including Attached Pilasters, Columns, Piers, Abutments, Pillars, Posts, Struts, Buttresses, String Or Lacing Courses, Parapets, Coping, Bed Blocks, Anchor Blocks, Plain Window Sills, Fillets, Sunken Floor, Etc. Up To Floor Five Level, Excluding The Cost Of Centering, Shuttering And Finishing:1:11 / 2:3 ( 1 Cement : 11 / 2 Coarse Sand :3 Graded Stone Aggregate 20 Mm Nominal Size ) 10 22.5 : Providing And Laying Water Proofing Treatment In Sunken Portion Of Wcs, Bathroom Etc., By Applying Cement Slurry Mixed With Water Proofing Cement Compound Consisting Of Applying : A ) First Layer Of Slurry Of Cement @ 0.488 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.253 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours. B ) Second Layer Of Slurry Of Cement @ 0.242 Kg / Sqm Mixed With Water Proofing Cement Compound @ 0.126 Kg / Sqm. This Layer Will Be Allowed To Air Cure For 4 Hours Followed With Water Curing For 48 Hours. The Rate Includes Preparation Of Surface, Treatment And Sealing Of All Joints, Corners, Junctions Of Pipes And Masonry With Polymer Mixed Slurry. 11 6.40 : Providing And Laying Gypsum Panel Partitions 100 Mm Thick With Water Proof Gypsum Panels Of Size 666X500x100 Mm, Made Of Calcite Phosphor Gypsum Fixed With Tongue And Groove, Jointed With Bonding Plaster As Per Manufacturers Specifications In Superstructure Above Plinth Level Up To Floor V Level. Gypsum Blocks Will Have A Minimum Compressive Strength Of 9.3 Kg / Cm2 12 6.41 : Extra For Gypsum Panel Partitions In Superstructure Above Floor V Level For Every Four Floors Or Part Thereof. 13 13.60.1 : Wall Painting With Acrylic Emulsion Paint Of Approved Brand And Manufacture To Give An Even Shade:Two Or More Coats On New Work 14 13.99.1 : Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture Of Required Colour To Give An Even Shade :One Or More Coats On Old Work 15 13.26 : Providing And Applying Plaster Of Paris Putty Of 2 Mm Thickness Over Plastered Surface To Prepare The Surface Even And Smooth Complete. 16 21.1.1.1 : Providing And Fixing Aluminium Work For Doors, Windows, Ventilators And Partitions With Extruded Built Up Standard Tubular Sections / Appropriate Z Sections And Other Sections Of Approved Make Conforming To Is : 733 And Is: 1285, Fixing With Dash Fasteners Of Required Dia And Size, Including Necessary Filling Up The Gaps At Junctions, I.E. At Top, Bottom And Sides With Required Epdm Rubber / Neoprene Gasket Etc. Aluminium Sections Shall Be Smooth, Rust Free, Straight, Mitred And Jointed Mechanically Wherever Required Including Cleat Angle, Aluminnium Snap Beading For Glazing / Paneling, C.P. Brass / Stainless Steel Screws, All Complete As Per Architectural Drawings And The Directions Of Engineer-In-Charge. ( Glazing, Paneling And Dash Fasteners To Be Paid For Separately ) :For Fixed Portionanodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15 ) 17 21.1.2.1 : For Shutters Of Doors, Windows & Ventilators Including Providing And Fixing Hinges / Pivots And Making Provision For Fixing Of Fittings Wherever Required Including The Cost Of Epdm Rubber / Neoprene Gasket Required ( Fittings Shall Be Paid For Separately ) Anodised Aluminium ( Anodised Transparent Or Dyed To Required Shade According To Is : 1868, Minimum Anodic Coating Of Grade Ac 15 ) 18 9.100.1 : Providing And Fixing Aluminium Handles, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Etc. Complete:125 Mm 19 21.3.2 : Providing And Fixing Glazing In Aluminium Door, Window, Ventilator Shutters And Partitions Etc. With Epdm Rubber / Neoprene Gasket Etc. Complete As Per The Architectural Drawings And The Directions Of Engineer - In -Charge. ( Cost Of Aluminium Snap Beading Shall Be Paid In Basic Item ) :With Float Glass Panes Of 5.50 Mm Thickness 20 11.48.2 : Grouting The Joints Of Flooring Tiles Having Joints Of 3 Mm Width, Using Epoxy Grout Mix 0.70 Kg Of Organic Coated Filler Of Desired Shade ( 0.10 Kg Of Hardener And 0.20 Kg Of Resin Per Kg ) . Including Filling / Grouting And Finishing Complete As Per Direction Of Engineer-In-Charge.Size Of Tile 600X600 Mm 21 11.49.2 : Providing And Laying Vitrified Tiles In Floor With Different Sizes ( Thickness To Be Specified By The Manufacturer ) , With Water Absorption Less Than 0.08% And Conforming To Is : 15622, Of Approved Brand & Manufacturer, In All Colours And Shade, Laid With Cement Based High Polymer Modified Quick Set Tile Adhesive ( Water Based ) Conforming To Is : 15477, In Average 6 Mm Thickness, Including Grouting Of Joints ( Payment For Grouting Of Joints To Be Made Separately ) .Size Of Tiles 600X600 Mm 22 11.50 : Deduct For Not Grouting The Joints With White Cement And Matching Pigment In The Items Of Fixing Of Vitrified Tiles 23 8.31 : Providing And Fixing Ist Quality Ceramic Glazed Wall Tiles Conforming To Is: 15622 ( Thickness To Be Specified By The Manufacturer ) , Of Approved Make, In All Colours, Shades Except Burgundy, Bottle Green, Black Of Any Size As Approved By Engineerin-Charge, In Skirting, Risers Of Steps And Dados, Over 12 Mm Thick Bed Of Cement Mortar 1:3 ( 1 Cement : 3 Coarse Sand ) And Jointing With Grey Cement Slurry @ 3.3Kg Per Sqm, Including Pointing In White Cement Mixed With Pigment Of Matching Shade Complete. 24 9.1.1 : Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia & Length ( Hold Fast Lugs Or Dash Fastener Shall Be Paid For Separately ) .Second Class Teak Wood 25 9.53 : Providing 40X5 Mm Flat Iron Hold Fast 40 Cm Long Including Fixing To Frame With 10 Mm Diameter Bolts, Nuts And Wooden Plugs And Embeddings In Cement Concrete Block 30X10x15 Cm 1:3:6 Mix ( 1 Cement : 3 Coarse Sand : 6 Graded Stone Aggregate 20 Mm Nominal Size ) 26 Od271499 / 2023_2024 : Providing And Fixing Single Shutter Doors Of Engineered Wood For Opening Size Of 1000 Mm *2100 Mm Hinged Type Openable On One Side. The Door Shutter Shall Be Of 40 Mm Thickness ( Min ) With Perimeter Seal And Core Filling With Tubular Particle Board And Polished Veneer On Both Sides As Per Design / Shade As Selected. The Door Jambs Shall Be Of 125*45 ( Min ) . Architrave Shall Be Of 65*12 Mm And Shall Vary In Line With The Site Conditions. The Architrave Material Provided Shall Be Of Lvl ( Laminated Veneer Lumber ) . Rate Includes Fixing The Door Accessories. 27 9.23 : Extra For Providing Lipping With 2Nd Class Teak Wood Battens 25 Mm Minimum Depth On All Edges Of Flush Door Shutters ( Over All Area Of Door Shutter To Be Measured ) . 28 Od271508 / 2023_2024 : Providing And Fixing Cup Board Shutters 18 Mm Thick, With Multi Wood Is: 12823 Marked, Exterior Grade ( Grade I Type Ii ) , Having One Side Decorative Lamination And Other Side Balancing, Including Iind Class Teak Wood Lipping Of 25 Mm Wide X12 Mm Thick With Necessary Screws And Bright Finished Stainless Steel Piano Hinges. It Also Includes Magnetic Catcher And Aluminum Handles And And Locking Arrangements Complete As Per Direction Of The Engineer -In-Charge. 29 9.82 : Providing And Fixing Bright Finished Brass Hanging Type Floor Door Stopper With Necessary Screws, Etc. Complete. 30 9.92.1 : Providingand Fixing Chromium Plated Brass Handles With Necessary Screws Etc. Complete:125 Mm 31 Od3774 / 2022_2023 : Providing And Fixing Mosqito Net ( Steel ) For Windows And Doors Including Aluminum Sectionand All Fittings With Locking Arragement Approved By The Site Enginneer In Charge ( No Extra Cost Paid On This Account ) . 32 12.45.3 : Providing And Fixing False Ceiling At All Height Including Providing And Fixing Of Frame Work Made Of Special Sections, Power Pressed From M.S. Sheets And Galvanized With Zinc Coating Of 120 Gms / Sqm ( Both Side Inclusive ) As Per Is : 277 And Consisting Of Angle Cleats Of Size 25 Mm Wide X 1.6 Mm Thick With Flanges Of 27 Mm And 37 Mm, At 1200 Mm Centre To Centre, One Flange Fixed To The Ceiling With Dash Fastener 12.5 Mm Dia X 50 Mm Long With 6 Mm Dia Bolts, Other Flange Of Cleat Fixed To The Angle Hangers Of 25X10x0.50 Mm Of Required Length With Nuts & Bolts Of Required Size And Other End Of Angle Hanger Fixed With Intermediate G.I. Channels 45X15x0.9 Mm Running At The Spacing Of 1200 Mm Centre To Centre, To Which The Ceiling Section 0.5 Mm Thick Bottom Wedge Of 80Mm With Tapered Flanges Of 26 Mm Each Having Lips Of 10.5 Mm, At 450 Mm Centre To Centre, Shall Be Fixed In A Direction Perpendicular To G.I. Intermediate Channel With Connecting Clips Made Out Of 2.64 Mm Dia X 230 Mm Long G.I. Wire At Every Junction, Including Fixing Perimeter Channels 0.5 Mm Thick 27 Mm High Having Flanges Of 20 Mm And 30 Mm Long, The Perimeter Of Ceiling Fixed To Wall / Partition With The Help Of Rawl Plugs At 450 Mm Centre, With 25 Mm Long Dry Wall Screws @ 230 Mm Interval, Including Fixing Of Gypsum Board To Ceiling Section And Perimeter Channel With The Help Of Dry Wall Screws Of Size 3.5X25 Mm At 230 Mm C / C, Including Jointing And Finishing To A Flush Finish Of Tapered And Square Edges Of The Board With Recommended Jointing Compound, Jointing Tapes, Finishing With Jointing Compound In 3 Layers Covering Upto 150 Mm On Both Sides Of Joint And Two Coats Of Primer Suitable For Board, All As Per ManufacturerS Specification And Also Including The Cost Of Making Openings For Light Fittings, Grills, Diffusers, Cutouts Made With Frame Of Perimeter Channels Suitably Fixed, All Complete As Per Drawings, Specification And Direction Of The Engineer In Charge But Excluding The Cost Of Painting With:12.5 Mm Thick Tapered Edge Gypsum Moisture Resistant Board 33 Od271634 / 2023_2024 : Providing And Fixing Of Podium Stand Made Up Of Hard Wood Of Size 120*60*40. It Includes One Drawer With Open Compartment And Complete As Per The Direction Of Engineer In Charge 34 10.25.1 : Item Shifted To Head 14 As Item 14.74Steel Work Welded In Built Up Sections / Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer Using Structural Steel Etc. As Required.In Stringers, Treads, Landings Etc. Of Stair Cases, Including Use Of Chequered Plate Wherever Required, All Complete 35 Toilet Andbathroom Fittings 36 9.117.2 : Providing And Fixing Factory Made Upvc Door Frame Made Of Upvc Extruded Sections Having An Overall Dimension As Below ( Tolerance ±1 Mm ) , With Wall Thickness 2.0Mm ( ±0.2 Mm ) , Corners Of The Door Frame To Be Jointed With Galvanized Brackets And Stainless Steel Screws, Joints Mitred And Plastic Welded. The Hinge Side Vertical Of The Frames Reinforced By Galvanized M.S. Tube Of Size19 X 19 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness And 3 Nos. Stainless Steel Hinges Fixed To The Frame Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Chargeextruded Section Profile Size 42X50 Mm 37 9.118.2 : Providing And Fixing To Existing Door Frames30 Mm Thick Factory Made Polyvinyl Chloride ( Pvc ) Door Shutter Made Of Styles And Rails Of A Upvc Hollow Section Of Size 60X30 Mm And Wall Thickness 2 Mm ( ± 0.2 Mm ) , With Inbuilt Decorative Moulding Edging On One Side.The Styles And Rails Mitred And Joint At The Corners By Means Of M.S. Galvanised / Plastic Brackets Of Size 75X220 Mm Having Wall Thickness 1.0 Mm And Stainless Steel Screws.The Styles Of The Shutter Reinforced By Inserting Galvanised M.S. Tube Of Size 25X20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Lock Rail Made Up Of H Section, A Upvc Hollow Section Of Size 100X30 Mm And 2 Mm ( ± 0.2 Mm ) Wall Thickness Fixed To The Shutter Styles By Means Of Plastic / Galvanised M.S. U Cleats. The Shutter Frame Filled With A Upvc Multi-Chambered Single Panel Of Size Not Less Than 620 Mm, Having Over All Thickness Of 20 Mm And 1 Mm ( ± 0.1 Mm ) Wall Thickness. The Panels Filled Vertically And Tie Bar At Two Places By Inserting Horizontally 6 Mm Galvanised M.S. Rod And Fastened With Nuts And Washers, Complete As Per ManufacturerS Specification And Direction Of Engineer-In-Charge. 38 17.81 : Providing And Fixing Floor Mounted, White Vitreous China Single Piece, Double Traps Syphonic Water Closet Of Approved Brand / Make, Shape, Size And Pattern Including Integrated White Vitreous China Cistern Of Capacity 10 Litres With Dual Flushing System, Including All Fittings And Fixtures With Seat Cover, Cistern Fittings, Nuts, Bolts And Gasket Etc Including Making Connection With The Existing P / S Trap, Complete In All Respect As Per Directions Of Engineer-In-Charge. 39 17.28.2.1 : Flexible Pipe32 Mm Dia 40 17.29 : Providing And Fixing 100 Mm Sand Cast Iron Grating For Gully Trap. 41 17.7.2 : Providing And Fixing Wash Basin With C.I. Brackets, 15 Mm C.P. Brass Pillar Taps, 32 Mm C.P. Brass Waste Of Standard Pattern, Including Painting Of Fittings And Brackets, Cutting And Making Good The Walls Wherever Require:White Vitreous China Wash Basin Size 630 X 450 Mm With A Single 15 Mm C.P. Brass Pillar Tap 42 18.15.1 : Providing And Fixing Brass Bib Cock Of Approved Quality :15 Mm Nominal Bore 43 18.8.2 : Providing And Fixing Chlorinated Polyvinyl Chloride ( Cpvc ) Pipes, Having Thermal Stability For Hot & Cold Water Supply, Including All Cpvc Plain & Brass Threaded Fittings I / C Fixing The Pipe With Clamps At 1.00 M Spacing. This Includes Jointing Of Pipes& Fittings, With One Step Cpvc Solvent Cement And The Cost Of Cutting Chases And Making Good The Same Including Testing Of Joints Complete As Per Direction Of Engineer-In-Charge.Concealed Work, Including Cutting Chases And Making Good The Wall Etc.20 Mm Nominal Outer Dia Pipes 44 50.18.9.9.1 : Providing And Fixing Pvc Pipes Includings Jointing Of Pipes With One Step Pvc Solvent Cement, Trenching, Refilling & Testing Of Joints Complete As Per Direction Of Engineer In Charge.110 Mm Dia 6Kgf / Cm2 45 50.18.9.22.1 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Elbow 46 50.18.9.22.11 : Providing And Fixing Pvc Moulded Fittings / Accessories For Rigid Pvc Pipes, Including Jointing With Pvc Solvent Cement - 110 Mm Dia Socket / Coupling 47 18.22.2 : Providing And Fixing C.P. Brass Shower Rose With 15 Or 20 Mm Inlet:150 Mm Diameter 48 18.53.1 : Providing And Fixing C.P. Brass Angle Valve For Basin Mixer And Geyser Points Of Approved Quality Conforming To Is: 893115 Mm Nominal Bore 49 18.21.1.1 : Providing And Fixing Uplasticised Pvc Connectionpipe With Brass Unions:30 Cm Length15 Mm Nominal Bore 50 50.17.1.5 : Supplying And Fixing Cp Health Faucet Superior Quality ( Jagur Or Equvalent Make ) Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 51 50.17.1.1 : Supplying And Fixing Stainless Steel Soap Dish Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 52 50.17.1.2 : Supplying And Fixing Cp Towel Rod 45Cm Or Nearest Available Length Including Cost Of Materials And Labour Charges Etc Complete As Per The Direction Of Site Engineer-In-Charge. 53 50.9.15.2 : Supplying And Fixing 300 Mm Aluminium Aldrop 54 9.97.1 : Providing And Fixing Aluminium Tower Bolts, Isi Marked, Anodised ( Anodic Coating Not Less Than Grade Ac 10 As Per : 1868 ) , Transparent Or Dyed To Required Colour Or Shade, With Necessary Screws Complete:300X10 Mm 55 Electrical Works 56 Od275734 / 2023_2024 : Supply, Conveyance Installation Testing And Commissioning Complete With All Accessories And Lamps Etc. Directly On Wall Or Ceiling With Pvc Round Block Neatly Painted To Suit The Fitting And Giving Connection With Required Length Of 16 / 0.20 Mm 3 Core Copper Conductor Flex Wire Conforming To Relevant Iss And Giving Connections As Required.
1200 Mm 1 X 20 W Led Tube With Fittings 57 1.33 : Supplying And Fixing 3 Pin, 5 Amp Ceiling Rose On The Existing Junction Box / Wooden Block Including Connection Etc As Required. 58 Od273270 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Following Split Type High Wall Mounted Air Conditioner Unit With Cordless Remote Of Following Ratings Including Fixing Of Indoor & Outdoor Units, Initial Gas Charging As Per Manufacturer Standards, Giving Power Connection To Nearest Power Plug Point / Mcs, Connecting Indoor And Outdoor Units Using Hard Drawn Copper Refrigerant Pipes Insulated With Nitrile Rubber Or Equivalent Material Of Minimum 3 Mtrs, Pvc Insulated Flexible Copper Cable Of Minimum 3 Meters As Per Original Manufacturers Standards, Necessary Drain Water Line Using 20Mm Pvc Pipe Minimum 3 Mtrs. Necessary Opening On Wall Shall Be Made For Drawing Refrigerant / Power / Drain Lines And Shall Be Restored To Normal Using Cement Plastering. ( Drain Pipe Line Shall Be Properly Fixed And Clamped To Line And Level As Per The Direction Of Site Engineer In Charge ) . Approved Ot Equivalent Make Of 1.5Tr Twin Coil Capacity 5 Star Rated Air Conditioner Working On Single Phase 240 V, 50 Hz + / -1% Ac Supply With Approved Make External Stabilizer.
59 90.4.5.2 : Supply, Conveyance, Installation, Testing And Commissioning Of Ceiling Fans Of The Following Sizesusing Standard Accessories Excluding Resistance Type Regulator, Wiring The Down Rod With 16 / 0.20Mm Pvc Insulated And Pvc Sheathed 650 / 1100V Grade 3 Core Round Copper Conductor Flex Wire Or With Extended Original Wiring Etc. As Required. 60 Od273417 / 2023_2024 : Supply Of 18W Surface Recess Mounted Led Downlighter, High Efficiencyluminaire Wattage 18W. The Luminaire Should Have A Cri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Led Light Fixture Of 6000 K, Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. ( Make:Havells, Phillips, Wipro ) 61 Od273467 / 2023_2024 : Supply Of 9W Led Downlighter With A Nominal System Lumen Output Of Minimum 500 Lumens. System Wattage Should Not Exceed 9W. The Luminaire Shall Have A Rated System Lifetime Of 50, 000 Burning Hours. The Luminaire Should Have A Color Temperature Of 6000K And Cri>80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.95. Housing Shall Be Crca Powder Coated With Pmma Diffuser. Driver Shall Have 85% Efficiency. Similar To Wipro Make Ld80-530-Xxx-60-Xx*** Or Equivalent
62 Od273470 / 2023_2024 : Supply Of Mirror Light, High Efficiency With A Nominal System Lumen Output Of 900 Lumens. Luminaire Wattage Should Not Exceed 9W. The Luminaire Should Have A Cri > 80. Driver Of The Luminaire Shall Have Thd < 10% And Pf > 0.9. Slim Led Batten In Aluminium Housing And Decorative End Caps. Robust Driver With Wide Voltage Range 100-240 Volts And Inbuilt Protection. Aesthetically Designed Mirror Led Light Fixture Of 2700 K, Of Surface Mounting Which Provides Soft-Light And Glare Free Symmetrical Illumination. Simialr To Model Number D531027 Garnet 10W Of Wipro Make Or Equivalent.
63 1.10.2 : Wiring For Light Point / Fan Point / Exhaust Fan Point / Call Bell Point With 1.5 Sq.Mm Frls Pvc Insulated Copper Conductor Single Core Cable In Surface / Recessed Medium Class Pvc Conduit, With Modular Switch, Modular Plate, Suitable Gi Box And Earthing The Point With 1.5 Sq.Mm. Frls Pvc Insulated Copper Conductor Single Core Cable Etc As Required.Group B 64 1.24.1 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.5 / 6 Amps Switch 65 1.24.3 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.15 / 16 Amp Switch 66 1.24.4 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.3 Pin 5 / 6 Amp Socket Outlet 67 1.24.5 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.6 Pin 15 / 16 Amp Socket Outlet 68 1.27.1 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.1 Or 2 Module ( 75Mmx75mm ) 69 1.27.2 : Supplying And Fixing Following Size / Modules, Gi Box Alongwith Modular Base & Cover Plate For Modular Switches In Recess Etc As Required.3 Module ( 100Mmx75mm ) 70 1.14.1 : Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x1.5 Sq.Mm + 1X1.5 Sq.Mm Earth Wire 71 1.14.2 : Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2x 2.5 Sq. Mm + 1 X 2.5 Sq. Mm Earth Wire 72 1.14.3 : Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required2 X 4 Sq. Mm + 1 X 4 Sq. Mm Earth Wire 73 1.17.3 : Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required.3 X 1.5 Sq.Mm 74 1.21.1 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.20 Mm 75 1.21.2 : Supplying And Fixing Of Following Sizes Of Medium Class Pvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required.25 Mm 76 2.7.6 : Supplying And Fixing Following Way Prewired Sp&N Mcb Distribution Board Of Steel Sheet For 240 Volts On Surface / Recess Complete With Loose Wire Box, Terminal Connectors For All Incoming And Outgoing Circuits, Duly Prewired With Suitable Size Fr Pvc Insulated Copper Conductor Up To Terminal Blocks, Tinned Copper Bus Bar, Neutral Link, Earth Bar, Din Bar, Detachable Gland Plate, Interconnections, Powder Painted Including Earthing Etc. As Required. ( But Without Mcb / Rccb / Isolator ) 2+12 Way, Double Door 77 1.24.8 : Supplying And Fixing Following Modular Switch / Socket On The Existing Modular Plate & Switch Box Including Connections But Excluding Modular Plate Etc. As Required.Bell Push 78 2.12.1 : Supplying And Fixing Following Rating, Double Pole, 240 Volts, Isolator In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 79 2.14.2 : Supplying And Fixing Following Rating, Double Pole, ( Single Phase And Neutral ) , 240 V, Residual Current Circuit Breaker ( Rccb ) , Having A Sensitivity Current 30 Ma In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.40 Amps 80 2.10.1 : Supplying And Fixing 5 Amps To 32 Amps Rating, 240 / 415 Volts, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 81 1.25 : Supplying And Fixing Two Module Stepped Type Electronic Fan Regulator On The Existing Modular Plate Switch Box Including Connections But Excluding Modular Plate Etc. As Required. 82 1.38 : Supplying And Fixing Call Bell / Buzzer Suitable For Single Phase, 230 Volts, Complete As Required. 83 90.4.8 : Charges For Cutting Holes Suitable For Accommodating Exhaust Fans Up To 305Mm Sweep Including Plastering Colour Washing Etc. As Required. 84 Od279204 / 2023_2024 : Supply, Conveyance, Installation, Testing And Commissioning Of The Following Sizes Of Exhaust Fans In The Existing Opening, Fixing Necessary Bolt And Nuts, Making Good The Damages Etc. As Required Including Giving Connections With Required Length Of 24 / 0.20Mm Pvc Insulated And Pvc
Sheathed 3 Core Round Copper Conductor Flex Wire , Conforming To Relevant Iss.150 / 155 Mm, Single
Phase Pvc Type Light Duty Exhaust Fan With Shutters
85 Od279297 / 2023_2024 : Supply, Installation, Testing And Commissioning ( Sitc ) Of Instant Water Geyser Of Capacity-3Ltr, Product Warranty-Min 2 Yrs, Heating Element Warranty-Min 2 Yrs, Tank Capacity-Min 5 Yrs Including Piping Accessories, Pressure Rating-Min 6.5 Bar, Stainless Steel Tank, Water Flow Rate-120 Ltr / Hr, Heating Element-Copper, Isi Certified ( Make:V-Guard, Crompton, Havells Or Equivalent ) As Per The Direction Of Engineer In Charge. 86 Od286554 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Hisense 44L, Single Door, Compact, Direct Cool Single 1 Star , Temperature Control, Metal Body , 201Kwh / Year , Ac 220-240, 50 Hz, Size 51*47*43.9, Weight 14 Kg, Warranty 1 Year On Refridgerator And 10 Years On Compressor From Hisense Refridgerator ( Silver, Rr60d4asb1 ) Or Equivalent As Per The Direction Of Engineer Incharge. 87 Od286663 / 2023_2024 : Supply , Installing , Testing, Commissioning Of Water Purifier-6 L Capacity Ro+Uf, Power-40-50 Wauto Shutoff And Overflow Protection, Filteration Capacity 8L / Hr , Fiter Life6000 Ltr Purifying Technology, Power -230 V , 50 Hz , 20V Make :Eureka Forbes Sure Delight Nxt 6 Or Equivalent, As Per The Direction Of Engineer In Charge. 88 1.56 : Supplying And Fixing Suitable Size Gl Box With Modular Plate And Cover In Front On Surface Or In Recess, Including Providng And Fixing 2 Nos. 3 Pin 5 / 6 A Modular Socket Outlets And 2 Nos. 5 / 6 A Modular Switches, Connection Etc. As Required. ( For Light Plugs To Be Used In Non Residential Buildings ) . 89 1.57 : Supplying & Fixing Suitable Size Gl Box Wih Modular Plate And Cover In Front On Surface Or In Recess Including Providing And Fixing 25 A Modular Socket Outlet And 25 A Modular Sp Mcb, C Curve Including Connections, Painting Etc. As Required. 90 1.59 : Dismantling Of Ceiling Fan And Painting The Same With With One Or More Coats Of Spray Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade, Including Cleaning Of Surface With Detergent And Replacing The Damaged Rubber Reel, Nuts And Bolts With Washers And Safety Pins Reinstalling The Same As Required. 91 Od276779 / 2023_2024 : Supply And Fixing Of Fire Retardent / Extinguishing Electric Insulated Synthetic Mat Of Standard Size Minimum 2 Mm Thick For 3.3Kv Grade As Directed By Engineer In Charge 92 Dismantling Works 93 Od274140 / 2023_2024 : Charges For Dismantling Existing Wiring Of Light / Fan / Bell / Points Without Switch Boards Such As Pvc Conduits, Wire, Earthing Conductor, Circuit Mains, Etc Without Damages And The Samestocked At Electrical;L Store Room Near The Site.& Collected Hand Receipt 94 Od280539 / 2023_2024 : Charges For Dismantling Existing Ceiling / Wall / Exhaust Fan And Fittings Of All Sizeswith All Accessories Without Damages And Stocked At Electrical Store Room Near The Site & Collected Hand Receipt As Per Direction Of The Engineer Incharge. 95 Od274214 / 2023_2024 : Charges For Dismantling Of Existing Pre-Wired Ordinary 40 W Flurecent Tube Light Fittings Made Of .5Mm Thick Crca Sheet Accessories And Lamps ( Tube Set And Accessories Excluding Ball& Down Rod ) With Out Damage And Stocked At Electrical Store In Consultation With Ae / Aee Electrical Kshb , Also The Same Recorded In Handing Over Register As Per Direction From Kshb Engineer In Charge 96 Od274705 / 2023_2024 : Charges For Dismantling Existing Ac With Stabilizer, Stat, Copper Pipe Etc Without Damages And The Samestocked At Electrical & Collected Hand Receipt Store Room Near The Site.
97 Od274723 / 2023_2024 : Charges For Dismantling Existing Angle / Ceiling / Wall Light Fittings With All Accessories Without Damages And Stocked At Electrical Store Room Near The Site & Collected Hand Receipt
98 Conference Hall ( Rt-Eklm ) 99 Od273576 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Usb Ptz Full Hd Video Conferencing Camera , Full Hd Video Conferencing Camera - 10X Optical Zoom As Per Direction Of Engineer In Charge. ( Makea&T Klick U1 Sb Ptz Or Equivalent 100 Od273577 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Floor Mount Trolley Stand 65, 75 - Custom
Floor Mount Trolley Stand Size 65, 75 As Per Direction Of Engineer In Charge 101 Od273578 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Interactive Flat Panel Display Features Enhanced , Wi-Fi 6, Broad Compatibility, 65W Powered Usb Type-C, High Quality Sound System, Antimicrobial, Surface Secure, User Profiles, Android 11 Active Screen Size ( Inch ) : 65, Display Backlight : Led, Resolution : 3840 X 2160 ( 4K ) , Lcd Brightness : 400 Cd / M2, Life Time : >50000 Hrs, Touch Surface Material :Toughened Tempered Glass, Touch Surface Technology : Anti-Glare Glass , Touch Surface Hardness : H7, Touch Points : 20 Points, Touch Screen, Response Time : 6Ms, Viewing Angle : 178°, Android Version: 11, Ram : 4Gb, Rom : 64 Gb, Speaker Max. Power Output : 15 W X 2 Speakers Including Accessories : Wall Mount Kit, Remote, Hdmi, Power & Usb Cables. Warranty : 3 Years Onsite Warranty + 2Yr Amc ( Make: Newline Or Equivalent. ) .
Including,
Ups - 1Kva Ups With Inbuilt Battery,
Ups Cabinet - Wall Mount Metal Cabinet For 1 Kva Ups,
Floor Mount Trolly Stand - Heavy Duty,
Wireless Mouse & Keyboard As Per Direction Of Engineer In Charge 102 Od275030 / 2023_2024 : Supply, Ofwi Fi Modem Supported In To The Existing Land Linetelephone System Standard Make & Model ( D Link Dsl -2750 U Or Equivalent Model ) As Per Direction Of Engineer In Charge 103 Od275081 / 2023_2024 : Supply, Installation, Testing And Commissioning Of Portable Usb & Bluetooth Conference Phone , “Plug-And-Play” Connectivity With Driver-Less Usb, Bluetooth, Nfc And Audio In / Out Connection Interfaces As Per Direction Of Engineer In Charge ( Make:Yamaha Yvc-330 High-Performance Unidirectional Microphones Or Equivalent ) 104 1.53.1 : Supplying And Drawn Of Utp 4 Pair Cat 6 Lan Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required1 Run Of Cable
Contract Date: Feb 05, 2024 Contract Value : 18.23 Lakh
Government Departments No of Bidders 2
21.
Public Administrative Department #3210506 AOC
Providing Electrical Material , Erecting Electrical Work And Repairing Of Electrical Equipment Of Municipal Council Chalisgaon For Fy 2023-24-2 Supplying 1.5 Sq Mm Service Wire Bundle ( 2Core ) 90 Mtr 3 Supplying 2.5 Sq Mm Service Wire Bundle ( 2Core ) 90 Mtr 4 Supplying 4 Sq Mm Service Wire Bundle ( 2Core ) 90 Mtr 5 Supplying 6 Sq Mm Service Wire Per ( 2Core ) 90 Mtr 6 Supplying 10 Sq Mm Service Wire ( 2Core ) 90 Mtr 7 Supplying Mains With 2X1.5 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places As Per Specification No: Wgma / Bw 8 Supplyin Mains With 2X2.5 Sq.Mm F.R Copper Pvc Insulated Wire Laid In Provided Conduit / Trunking / Inside Pole / Bus Bars Or Any Other Places. As Per Specification No: Wgma / Bw 9 Supplying Pvc Insulated Pvc Round Sheathed 4 Sq.Mm ( 56 No. X 0.30 Mm Dia. ) 3 Core Flexible Multi Stranded Copper Industrial Cable For Voltage Grade Up To 1.1 Kv 10 Supplying 6 To 32 A Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. 11 Supplying 40A To 63A Spmcb Suitable To Fix In 1 Module Of Modular Switch In Provided Box Complete & Duly Concealed With Necessary Material And Connected. 12 Providing & Erecting 3 Pole Mccb Upto 100A, 415V, With Short Circuit Rating 25 Ka ( Ics=100% Of Icu ) , Adjustable Thermal ( Overload ) Setting And Fixed Magnetic Setting With Provided Leads, Provision For Installation Of Shunt / Uv / Trip Alarm Contact And Mccb Should Have Phase Barriers Both Sides, In Provided Enclosure On Iron / Gi Frame As Per Specification No. Sw-Swr / Mccb 13 Supplying Led 18W Tube Light Fitting ( 4 Feet ) With Polycarbonate Housing, Heat Sink, Integrated Hf Electronic Driver Complete 14 Supplying Fuse Bridges With Base Hc Type Fuse Links 240V 63A Erected On Polished Wooden Block Complete 15 Supplying 4 Pole Power Contactor 63 A With Coil Voltage Of 220 / 240 V 16 Supplying 4 Pole Power Contactor 80A-130A With Coil Voltage Of 220 / 240 V 17 Supplying Quartz Electronic Time Switch Having 24 Hour Dial To Work On 250 V 50 Cycle Ac Having Built In Rechargeable Nickel Cadmium Batteries To Run The Time Switch On Failure Of Supply Having Switch Contact Rating Upto 16A To Use Independently Or In Conjunction With Contactor. 18 Supplying 12 V / 150Ah Tubular Battery With Battery Terminal Wire, Duly Charged Complete With 36 Months Warranty Complete 19 Supplying & Erecting 12 V 88 Ah Heavy Duty Plate Type Battery With Terminal Wire Duly Charged Complete Suitable For Dg Set With Warrantee For 3 Years 20 Supplying Regular / Standard Model Ceiling Fan Of 1400Mm. Sweep Complete Erected In Position As Per Specification No. Fg-Fn / Cf 21 Providing Bracket Fan 400 Mm. Sweep A. C. 230 Volts 50 Cycles 1350 R.P.M. Oscillating Type, Plastic Or Metal Blades Chrome Plated Guard With Regulator And Moisture Proof Treatment To Winding And With ‘E’ Class Insulation. 22 Supplying Fresh Air Cum Exhaust Fan Of Light Duty 250 V A.C. 50 Cycles 300Mm. 1400 Rpm Rust Proof Body & Blades, Wire Mesh, Duly Erected In An Approved Manner. 23 Supplying 10-12W, 230V Integral Type Led Lamp Suitable For B-22 / E-27 Base. 24 Mode Of Work - Supplying, Erecting And Comissioning Part Only 25 Supplying & Erecting Street Light Control Panel In Powder Coated Crca 14 / 16 Swg Sheet, Outdoor Type, Three Phase, 415V Consisted Of Suitable Rating Contactor, 24 Hrs Digital / Astronomical Time Switch With Minimum 5 Years Battery Backup, Tpn Mcb 63 A Auto / Manual Selector Switch, On / Off Push Buttons, Indicator Lamps, Control Wiring, Metering Device, Etc For Automatic Operation & Overcurrent, Short Circuit, Earth Fault Protection Of Street Lights Upto The Max Load Of 12 Kw On Provided Iron Frame / Cc Foundation Complete. 26 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 4 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / All 27 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / All 28 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 2 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / All 29 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 4 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 30 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 6 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 31 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 10 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 32 Supplying, Erecting & Terminating Fr Xlpe Insulated, Galvanised Steel Formed Wire Armoured ( Strip ) Cable 1100 V, 4 Core 16 Sq. Mm. Aluminium Conductor Complete Erected With Glands & Lugs, On Wall / Trusses / Pole Or Laid In Provided Trench / Pipe As Per Specification No. Cb-Lt / Al 33 Supplying & Erecting G.I. Pipe ‘A’ Class 40 Mm Dia. Erected For Enclosing Xlpe Armoured Cable On Wall / Pole As Per Specification No. Cb-Ce ( As Per Csr 21-22 7-6-2 ) 34 Supplying And Erecting Architectural Pole Of 4Mtr Height, Pole Placed With A Aluminium / Cast Iron Embellishment On The Bottom & Middle Section For Aesthetic & Decorative Purpose, Pole Shall Have Aluminium / Cast Iron Casting On The Base Middle And On The Joint Giving It Decorative Look, The Base Aluminium / Cast Iron Casting Shall 148Od With A Height 180Mm The Casting Will Have Ring On The Top 20Mm Thickness, The Middle Al / Cast Iron Casting Shall Be Of Conical Design With Bottom Section Of 145 Od Having 3 Ring Of 15Mm Each. The Conical Casting Shall Taper For 145 Od On Bottom To 92Mm On Top , The Pole With Inbuilt Junction Box To Fix 32 Amp Connectors & 6 Amp Mcb Inside Cut Window Of The Bottom Pipe With Suitable Size ( As Per Attached Drawing ) ( Non Dsr Item ) 35 Supplying And Erecting Attractive / Decorative Type Of Bracket With Reducer / Expander For Holding Decorative Fixture On Provided Main Pole Having All The Arrangement Perpendicular To Ground , The Bracket Type Is The Double Arm Shall Have Span With 1000Mm With In The Middle Made Of 8 Mm Rod With Flower Leaf Design ( As Per Attached Drawing ) ( Non Dsr Item ) 36 Supplying And Erecting Attractive / Decorative Type Of Bracket With Reducer / Expander For Holding Decorative Fixture On Provided Main Pole Having All The Arrangement Perpendicular To Ground , The Bracket Type Is The Single Arm Shall Have Span With In The Middle Made Of 8 Mm Rod With Flower Leaf Design ( As Per Attached Drawing ) ( Non Dsr Item ) 37 Supplying And Erecting Of Decorative Luminaire Made Of Spun Aluminium Body With Pressure Die-Cast Heat Management ( Pdchm ) And The Ip Optical Compartment With High Power Led Is Comprised Of Deep Drawn Chemically Polished And Co-Extruded Thransformed Polycarbonate Protector Stabilzed Agent Uv Rays Suitable For 40-60 W Led Fitting Should Be Hangging Type Mounting Decorative Fixture With Inbuilt Driver With Efficiency >0.9 And Having Surge Protection Device Of 10 Kva Colour Temperature 3000K / 4000K / 5700K Natural Day Light Led, Led To Be Osaram / Cree / Bridgelux & Driver To Be Make With Philips / Fulham / Osaram ( As Per Attached Drawing ) ( Non Dsr Item ) 38 Making M- 20 Grade Reinforced Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T / Sq.M At 1.5 M Depth Including Supply Of Steel, Concrete, Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( For 6M To 8M High Octagonal / Conical Gi Pole ) . ( As Per Csr 21-22 16-3-9 ) 39 Supplying And Laying ( Including Excavation Of Suitable Width & Depth Up To 90 Cm ) 50 Mm Outside Dia. Double Wall Corrugated Pipes ( Dwc ) Of Hdpe For Enclosing Cable Below Ground / Road Surface, To Required Depth Complete ( As Per Csr 21-22 7-6-9 ) . 40 Providing Pipe Type Earthing With 40Mm. Dia. G.L. Pipe Or 20 Mm Dia. G.L. Rod Complete With All Materials As Per Specification No. Ea-Ep ( As Per Csr 21-22 9-1-4 ) 41 Supplying And Erecting Led Square / Circular 5 To 8W Down Lighter Having Pressure Die-Cast Aluminium Housing, Opal Translucent Cover, Mounting Arrangement With Board For Surface Type Or Spring Loaded Mounting Clips For Flush Type Complete. 42 Supplying Led Concealed Type Foot / Step Light With Aluminium Body For Indoor / Outdoor Application Suitable For Upto 4W-6W Led Including Driver And Erecting By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface. 43 Supplying Led Up Down Light With Aluminium Body For Indoor / Outdoor Application Suitable For Upto 4W-6W Led Including Driver And Erecting By Making Necessary Arrangement / Recess In Wall To Make It Flush With Surface. 44 Supplying And Erecting Led Flexible Strip Light 5M Length Upto 25W Conforming Ip 65 Of Any Colour With Driver Complete. 45 Supplying And Erecting Gi Strip Of Required Size Used For Earthing On Wall And / Or Any Other Purpose With Necessary Gi Clamps Fixed On Wall Painted With Bituminous Paint In An Approved Manner With Joints Required. As Per Specification No Ea-Ep. 46 Mode Of Work - Repairing Works Only 47 Rewinding Motor Of The 1200 / 1400 Mm Ceiling Fan And Over Hauling Including Minor Repairs Lubricating Of Ball Bearings & Bush Bearing, And Replacing Condenser, Screws Etc. Testing Of Fan For Original Speed And Consumption With Guarantee For One Year. 48 Repairing Of Generator Focus Lamp With Chock, Connector Coil Etc 49 Servising Of Generator Focus Lamp 50 Mode Of Work - Repairing And Providing Municipal Council Ac Units 51 Providing Servicing Of 1 / 1.5 / 2 / 3 Tr Capacity Split / Window Air Conditioning Unit Complete With All Necessary Material. Job Includes Checking Of Performance Of Unit, Cleaning Of Filters Of Indoor Unit, Cleaning Of Outdoor Unit With Blower, Checking Of Electrical Connection Of Indoor As Well As Outdoor Unit And Submitting Report To Engineer Incharge. 52 Providing Flushing Out Cooling Coil And Condensor Coil Of Airconditioner Unit Refrigerant Pipes Internally With Dry Nitrogen Pressure In An Approved Manner 53 Providing Brazing Pipes And Checking Leakages In The Split / Window Unit Duly With Dry Nitrogen Pressure In An Approved Manner. 54 Providing Replacement Of Existing Unservicable Rotary / Scroll Compressor Of Air Conditioner 1.5 Tr By New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. 55 Providing Replacement Of Existing Unservicable Rotary / Scroll Compressor Of Air Conditioner 3 Tr By New One Of Same Capacity With Guarantee For One Year With Provided Refrigerant Complete. 56 Providing Replacement Of Unserviceable Starting Relay For Ac Unit. 57 Providing Replacement Of Unserviceable Starting / Running Capacitor For A / C Unit. 58 Providing Replacement Of Unserviceable Fan Motor Capacitor For A / C Unit. 59 Providing Replacement Of Unserviceable Pcb For A / C Unit Upto 3 Tr Capacity. 60 Providing Repair Of Of Faulty Pcb For Air Conditioning Unit Upto 3 Tr Capacity. 61 Supplying And Installing Of New Fan Motor For Condenser For Air Conditioning Unit 62 Supplying And Installing Of New Fan Motor For Indoor Unit Of Air Conditioner Up To 3 Tr Suitable To Operate On 230V To 250V Ac Or 280V To 340V Dc Supply Having 4 To 8 Poles As Per Requirement. 63 Supplying And Installing New Fan Blade Outdoor Unit For Air Conditioning Unit. 64 Providing Replacement Of Blower Of Indoor Unit For Air Conditioning Unit. 65 Providing Replacement Of Remote Of Indoor Unit For Air Conditioning Unit. 66 Providing And Fixing Indoor Plastic Cabinet With All Accessories 67 Providing Vaccumising The Airconditioner System To 200 Micron And Charging With R-22 Refrigerant For 1.5Tr Window / Split Air Conditioning Unit. 68 Providing Vaccumising The Airconditioner System To 200 Micron And Charging With R-22 Refrigerant For 3Tr Window / Split Air Conditioning Unit. 69 Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.0Tr To 1.2Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 70 Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor, Room Air Conditioning Unit 1.3Tr To 1.6Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 71 Supplying, Installing, Testing & Commissioning Split Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor. Room Air Conditioning Unit 1.7Tr To 2.0Tr Capacity Having Iseer Minimum 5.0 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 Having Copper Condenser, Minimum 2.5Pm Filter, Self Diagnosis Feature, Stabilizer Free Operation & Temperature Display On Indoor Unit, Noise Level Maximum 50Dba At Position In Provided Recess With Wooden Frame Complete Specification No. Ap-Ac / Wac 72 Supplying, Installing, Testing & Commissioning Cassette Type Variable Speed Inverter Technology With Minimum 3 To 1 Convertible Mode For Compressor Room Air Conditioning Unit 2.5Tr To 2.7Tr Capacity Having Iseer Minimum 5.00 Suitable To Operate On 250V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit Hi-Wall / Floor Mounting Type Complete With Refrigerant R32 / R410a Having Copper Condenser, Dust Filter, Self Diagnosis Feature, Stabilizer Free Operation, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 73 Supplying, Installing, Testing & Commissioning Cassette Type Room Air Conditioning Unit 3.4Tr To 3.9Tr Capacity With Refrigerant R32 / 410A 415V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit ( Mega Split ) Mounting Type Complete With Temperature Display On Indoor Unit, Minimum Dust Filter, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 74 Supplying, Installing, Testing & Commissioning Cassette Type Room Air Conditioning Unit 4Tr To 4.4Tr Capacity With Refrigerant R32 / 410A 415V, 50 Hz, A.C. Supply Having 1 No Of Air Handling Unit ( Mega Split ) Mounting Type Complete With Temperature Display On Indoor Unit, Minimum Dust Filter, Noise Level Maximum 50Dba At Position As Per Specification No. Apac / Wac 75 Mode Of Work - Electrical Fitting Part Only 76 Supplying And Erecting Pvc Trunking ( Pvc Casing-Ncapping ) Of Size 32 Mm With Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 77 Supplying And Erecting Upvc Reinforced Flexible Conduit 31 / 32 Mm In Dia. Conforming To I.S. With Required Number Of Couplings, Pvc Bushes, Check Nuts Etc. Complete. 78 Supplying And Erecting Hms Pvc Conduit 32 Mm Dia. With Pvc Accessories On Wall / Ceiling As Per Specification No: Wg-Ma / Con. 79 Point Wiring For Independent Plug In 20 Mm Isi Marked Hms Pvc Conduit With 1.5 Sq.Mm ( 2+1E ) Fr Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wg-Pw / Sw 80 Wiring For Plug On Board With Switch Socket, Copper Wiring And Earthing As Per Specification No: Wg-Pw / Sw 81 Providing Earthing With Galvanized Iron Earth Plate Size 60 X 60 X 0.6 Cm Complete With All Materials, Testing & Recording The Results As Per Specification No. Ea-Ep 82 Point Wiring In Pvc Trunking ( Casing-Capping ) With 1.5Sq.Mm ( 2+1E ) Fr Grade Copper Wire, Flush Type Switch, Earthing And Required Accessories As Per Specification No: Wgpw / Sw 83 Secondary Point Wiring For Additional Light / Bell Point In Pvc Trunking ( Casing-Capping ) With 1.5 Sq.Mm ( 2+1E ) Fr / Frlsh Grade Copper Wire With Required Accessories As Per Specification No: Wg-Pw / Sw 84 Supplying And Erecting Ceiling Rose / Batten Holder / Slanting Holder / Hanging Cord Switch / Hanging Bell Push / Pendent Holder Bakelite Base 6A. Erected On Filled Polypropylene Board Or Polished Double Wooden Block / Pvc Junction Box. 85 Supplying And Erecting Isi Mark Modular Type Switch 6A / 10A Duly Erected On Provided Plate And Box With Wiring Connections Complete. 86 Supplying And Erecting Flush Type Shockproof Plug Socket 6A & 16A ( 6 Pin ) With 16A Switch Combined With Indicator Lamp And Fuse With Gang Box On Wooden Board. 87 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 6 Modules Duly Erected. 88 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 13Modules Duly Erected. 89 Supplying And Erecting Pvc Surface Modular Switch Box With Double Mounting Plate For 18 Modules Duly Erected. 90 Mode Of Work - Repairing And Providing Led Lights Only 91 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 25W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 92 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 26W-45W Suitable To Operate On 230V A.C. 50 Hz. Having Pf>0.95 And Thd<10%. 93 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 46W-75W Suitable To Operate On 230V A.C.50 Hz. Having Pf>0.95 And Thd<10%. 94 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 76W-100W Suitable To Operate On 230V A.C.50 Hz. Having Pf>0.95 And Thd<10%. 95 Supplying And Erecting Electronic Type Driver For Outdoor Led Fittings Upto 101W-150W Suitable To Operate On 230V A.C.50 Hz. Having Pf>0.95 And Thd<10%. 96 Repairing For 18 To 45 W Led Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 97 Repairing For 50 To 75 W Led Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 98 Repairing For76 W To 100Wled Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 99 Repairing For76 W To 150W Led Flood Light With Spd, Shouldering, Cleaning Etc Complete With All Required Accessories 100 Repairing For 100 To 120 W Flood Light Plate With Al Required Accessories 101 Providing For 100 To 120 W Flood Light Plate With Al Required Accessories 102 Providing For 18W To 45 W Flood Light Plate With Al Required Accessories 103 Providing For 46W To 75 W Flood Light Plate With Al Required Accessories 104 Providing For 76W To 90 W Flood Light Plate With Al Required Accessories 105 Supplying And Erecting Integrated Led Flood Light Fitting Max. 50W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 5000 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 106 Supplying And Erecting Integrated Led Flood Light Fitting Max. 70W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 8400 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2 107 Supplying And Erecting Integrated Led Flood Light Fitting Max. 100W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 12000 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140-270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 108 Supplying And Erecting Integrated Led Flood Light Fitting Max. 155W Ip65 & Ik07 Class Having Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 18600 Lumens, Min. Efficacy Of 120 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.90, Operating Range Of 140 270V, Inbuilt Surge Protection Of 4 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver With U Shaped Bracket With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 109 Supplying And Erecting Street Light Bracket Made From 40 Mm. Dia ‘B’ Classg.I. Pipe, 0.6M. In Length Along With Pole Cap Of 300 Mm Length And 80 Mm Dia Duly Welded With Provided Leads As Per Specification No. Fg-Bkt / Bpc 110 Supplying And Erecting Integrated Led Street Light Fitting 23 To 25W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 2300 Lumens, Min. Efficacy Of 100 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3Years Warranty As Per Specification No Fg-Odf / Fls2. 111 Supplying And Erecting Integrated Led Street Light Fitting 70-75W Ip65 & Ik08 Class Having Single Piece Pressure Die-Cast Aluminium Housing, Having System Lumens Output Of Min. 7700 Lumens, Min. Efficacy Of 110 Lumen / W, Cri>70, Cct Upto 6500K, Thd<10%, P.F. >0.95, Operating Range Of 140-270V, Inbuilt Surge Protection Of 10 Kv, Life Class Of 50, 000 Hrs. At L70b50, Including Driver Complete With 3 Years Warranty As Per Specification No Fg-Odf / Fls2. 112 Mode Of Work - Shifting Of Highmast / Rsj / Round Pole 113 Dismentaling And Erecting Upto 20 M ( Clear Height ) Motorized / Non Motorized High-Mast On Provided Foundation With Carefully Dismentallation And Erection Of Wire, Luminaries Etc Complete 114 Making M- 20 Cement Concrete Foundation By Considering The Safe Soil Bearing Capacity At Site As 10 T / Sq. M At 2 M Depth Including Excavation And Fixing Provided Nut Bolts With The Help Of Template, Duly Plastered As Per Design Complete ( Upto 20 M Raising Lowering High Mast ) . 115 Providing Wire Rope For Raising Lowering High Mast 116 Providing Luminaries Ring For Raising And Lowering High Mast 117 Supplying And Erecting Rolled Steel Joist ( Girder ) Pole 125 X 70 Mm ( 13.3 Kg / M ) With Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Rsj ( For 8 Mtr ) 118 Supplying And Erecting G.I. Pipe Pole ‘B’ Class 80 Mm Dia 6 M Long With Pole Cap, Base Plate In Provided Foundation As Per Specification No. Oh-Pl / Gip 119 Painting Of Steel Tubular / Rail / Rsj Pole Above 6.0 Length Along With Street Light Pole Brackets, Clamps Etc By Scrapping The Existing Paint Complete As Per Specification No Cw -Ptg / Ptp. 120 Supplying And Erecting 3 Phase 4 Core 50 Sq.Mm. ( 3X50+1X35 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 121 Supplying And Erecting 3 Phase 4 Core 35 Sq.Mm. ( 3X35+1X25 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 122 Supplying And Erecting 3 Phase 4 Core 70 Sq.Mm. ( 3X70+1X50 ) Aerial Bunched Aluminium Cable Along With Necessary Accessories For Lt Distribution On Provided Lt Pole As Per Specification No. Oh-Cbl / Abc 123 Making Cement Concrete Foundation Including Excavation ( 60 X 60 X 150 ) Cm Deep In 1:3:6 Cement Concrete 20 X 25 Mm Stone Metal, ( 45 X 45 X 45 ) Cm / 45 Cm Dia. X 45 Cm Height Plinth Duly Plastered, With Necessary Curing And Finishing Complete. ( Above 6 M To 9 M Poles ) 124 Making Cement Concrete Foundation In 1:3:6 Cement Concrete, ( 20 To 25 ) Mm. Stone Metal Duly Plastered With Necessary Curing For Complete. ( Pole Muffing Or Any Other Purpose ) . 125 Mode Of Work - Extra-Other Accessories 126 Carrying Out Servicing Of Dg Set Up To 50 Kva With / Without Amf Panel Of Any Make To Ensure Smooth Running Of Dg Set For 30 Mins On Load. Checking For Abnormal Sound And Leakages, Carry Out Visual Inspection Of All Moving Parts, Oil Levels, Oil Filters, Fuel Filters, Air Filters And Clean Them Properly, Rectify The Minor Leakages If Any. Inspect Alternator, Stator And Rotor For Normal Speed & Proper Frequency, Examine Battery Charging With Monitoring System And Recording Voltages, Checking Battery Cells Gravity And Topping Up With Distilled Water, Checking V Belts With Necessary Adjustment, Checking And Retightening Of Nut Bolts Including Coupling Bolts Of Engine And Alternator, Checking & Cleaning Of Radiator And Leakage Testing Checking Of Radiator & Fuel Supply Hose Pipes, Checking Of Avr, Excitation Diodes, Its Connections Confirming Proper Output Voltage. Checking & Resetting Of Valve Tappets, Cleaning Of Dg Set Internally Using Blower, Cleaning Radiator, Attending Breakdowns As And When Required During One Month Period Or During Vip Visit Within 2 Hours Of Intimation And Submit The Servicing Report To Engineer In Charge. ( Non Comprehensive ) As Per Specification No. Gen-Ser-Amc 127 Supplying And Erecting Static Energy Meter With 240V 50 Hz. Ac Supply 5 To 30 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring And Display Kwh, Kvah, V, I, Pf, Frequency, Kw, Kva, Six Months History Of Energy & Md In Kw & Kva ) With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weather Proof Pvc Wires Duly Tested By Electric Supply Company. 128 Supplying And Erecting Static Energy Meter With 3 X 240V 50 Hz. Ac Supply 10 To 60 A, Isi Mark, Accuracy Class 1.0 With Backlit Lcd Display, ( Measuring And Display Trivector, V, I, Kw, Pf, Hz, Last Month History Of Kwh And Md In Kw ) With Special Features Like Tod, Tamper Logging, Optical Communication Port & Display In Absence Of Power & With Transparent Hinge Type Box Complete Erected On Polished Teak Wood Board Duly Wired With Required Size Of Weather Proof Pvc Wires Duly Tested By Electric Supply Company. 129 Government Of Maharashtra Public Works Department ( Electrical Wing ) Current Schedule Of Rates For 2021-2022 ( Note :- Use Of This Item In Critical Condition For Detail Refer Dtn )
Contract Date: May 12, 2023 Contract Value : 11.71 Lakh
Local Bodies No of Bidders 4
Maharashtra View Result →
23.
Educational and Research Institute #2205319 AOC
Supply, Testing, Installation & Commissioning Of Machinery / Equipment / Instrument / Hand Tools / Small Instruments Etc. In Various Trades Of Govt. I.T.I, Hili - 1 Computer I3, 7Th Generation, 8 Gb Ram, 1 Tb Hdd 2 Floor Mats ( 3’X2’ ) Standard Quality 3 Dc Arc Welding Machine ( 400A, Ocv 60–100 V, 60% Duty Cycle ) .Technical Specification:-Input Supply-440V 2Ph.50Hz. + / - 10%, Input Kva-16, No Load Consumption-2Amps, Welding Current Range-40-400A, Duty Cycle -60%, O.C.V-90V A / C, Protection Class-Ip21, Electrode Size-2-4Mm., Type Of Control-Magnetic Mooving Core Type, Type Of Cooling-Fan, Class Of Insulation-Double Fibre Glass With Varnish Covered Flat Conductor, Type Of Core-C.R.N.G.O, M-42Grade, No.Of Output Terminal-3, Mcb Rating-63Amps , Weight Approxx-130Kgs., Chasis Type-Tyre Wheel Mounted.Should Have Welding Amps & Volt Analog Meter. Accessories List:- 70Sqmm. Hofr Welding Cable -7.5Mtr. 70Sqmm. Hofr Earth Cable-5Mtr. Welding 400Amps Insulated Holder-01 Nos. Crocodile Type Earth Clamp-01 Nos. Welding Hand Screen With Glass-01 Set. Welding Cheeping Hammer-01 Nos. Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. 4 Air Conditioners Window And Split ( 1.5 Ton Used Preffered ) Standard Quality 5 Solar Photovoltaic Power Plant ( 20 Kw ) Pv Module Type- Polycrystalline / Monocrystalline, No. Of Pv Cells Per Module-72 Cells, Total Number Of Pv Modules-28-32 Nos, Max.Power, Pmp@Stc- 300 / 330 / 375Wp, Max.Power Tolerance ( % ) - Complied, Max.Power Voltage ( Vmp ) - 36.5 V, Max.Power Current ( Imp ) @Stc- 8.22 A, Open Circuit Voltage, Voc@Stc- 45 V, Short Circuit Current, [email protected] A, Nominal Voltage-24V, Nominal Wattage- 300Wp, Temp.Coefficient Of Voc-0.3104, Fill Factor-Complied, Temp.Coefficient Of Voc ( % / C ) -0.3104, Temp.Coefficient Of Pmp ( % / C ) -0.3948, Temperature Co-Efficient Of Isc% / °C ) -0.0687, Normal Operating Cell-46+ / - 2, Temperature ( Noct ) ( °C ) - 46+ / - 2, Operating Temperature ( °C ) -40 To 80, Max Temperature Rise Of Solar Cells Under Severe Working Conditions Over Max. Ambient Temp.-10 To 15Deg, Module Is Suitable To Operate At 500 Ambient Temp-Yes, Cell Efficiency-16%-19%, Module Efficiency-15.46%-15.63%, Temp.Coefficient Of Voc ( % / C ) -0.3104, Maximum System Voltage-36.5V Vmp, No. Of By-Pass Diodes-3 Nos, Mounting Arrangement For Solar Module, Clamp Type, Solar Module Frame-Anodized Aluminium, Material-Tempered & Low Iron Glass, Finish-Ethylene Vinyl Acetate, Types Of Sections Used- Aluminium / Ms Sections, Module Dimensions ( 1960 X 990 X 42 ) Mm, Pv Panel Weight ( Kg ) -20.5-22.5Kg, Module Life ( Minimum ) -25Years, Pv Array Area ( Sqm ) -64Sqm Approximate, Guaranteed Output Confirm- Yes, Total Plan Foot Area ( Sqm ) - 120Sqm, Control Area ( Sqm ) -120Sqm, String Monitoring Unit-Built In Pcu / Inverter 6 Over Lock Machine With Stool 4 Thread Over Lock Machine Direct Drive 7 Diagnostic Tool / Scanner For Motor Vehicle Standard Quality 8 Hammer Type Drilling Machine 4-20 Mm, 550 Watt ( 05 Years Amc Required. ) 9 Dual Gauges Set Refrigeration Equipment Standard Quality 10 Spanner D.E. Metric Spanner Double Ended, 6 - 32 Mm. 11 Cleaning Cloth Standard Quality 12 Fender Covers Standard Quality 13 Angle Grinder Machine 2400-Watt  14 Refrigerants M12 Standard Quality 15 Combination Plier Insulated, 200 Mm. 16 Embroidery Machine With Stool And Table 150 Sewing Operations, Lcd- Display, Automatic Needle Threader, Start / Stop Button, Automatically Stops Bobbin Winding, When Full 17 Gear Knob Covers Standard Quality 18 Pug Cutting Machine 220-240 V, 50-60 Hz, Cutting Capacity Upto 50Mm. 19 Empty Cylinder Standard Quality 20 Screwdriver Set Of 5 21 Bar Track Machine No Of Needles 1, No Of Threads 2, Stich Width 40 Mm, Pressure Foot Lifter 13Mm, Box Size 805X375x760 Mm, Heavy Duty ( 05 Years Amc Required. ) 22 Hard Toed Boots Standard Quality 23 Gas Welding Torch Set With Accessories Standard Quality 24 Refrigerants M-22 Standard Quality 25 Torque Wrench ( Standard / Ratchet Type ) , 14 To 68 Nm. 26 Press / Iron ( Any Type ) Standard Quality 27 Hydraulic Jack 20 Ton Standard Quality 28 Gas Cutting Torch Set With Accessories Standard Quality 29 Compressor Old Standard Quality 30 Wire Stripper 150 Mm 31 Pressing Table ( 6’X4’ ) Standard Quality 32 Hydraulic Press 20 Ton Standard Quality 33 Thread Cutter Set Of 20 Pcs Standard Quality 34 Compressor 50 Ltrs. Standard Quality 35 Measuring Tape 5 Meter 36 Garment , Made Ups And Home Furnishing Samples Standard Quality 37 Hydro Meter Standard Quality 38 Dies For Pipe Cutting 20 Pcs Set Standard Quality 39 Filter ( Sample ) Standard Quality 40 Line Dori Standard Quality 41 Drawing Board ( Any Size Wooden ) 850 Mm X 550 Mm 42 Multimeter Dc 200Mv -1000V, 0 – 10A & Ac 200Mv- 750V , 0-10A, Resistance 0- 20 Mω And 3 1 / 2 Digit. 43 Various Drive Socket Standard Quality 44 Drier ( Sample ) Standard Quality 45 Vernier Calliper Vernier Caliper, 150 Mm. 46 Display Board 900 Mm X 600 Mm 47 Oil Draining & Filling Equipment For Vehicle Standard Quality 48 Socket Set 20 Pcs Set Standard Quality 49 Capillary 400  Standard Quality 50 Plumb Bob 500 Gms Standard Quality 51 Types Of Scales:Normal Straight Big Ruler, Hip Curve, Leg Shaper, Pattern Master, Frenchcurve Standard Quality 52 Parts Washing Station Standard Quality 53 Universal Socket Set 10 Pcs Set Standard Quality 54 Capillary 500 Standard Quality 55 Safety Helmet Standard Quality 56 Computer Peripherals Dvd Rom, Blueray Drives, Speaker 57 A / C Leakage Tester Standard Quality 58 Tig Welding Machine With Water Cooled Torch 300 A, Argon Regulator, Gas Hose, Water Circulating System. Technical Specification:- Input Supply-440V 3Ph.50Hz. + / - 10%, Input Kva-10, No Load Consumption-0.5 Amps, Duty Cycle -60%, Welding Current Range-20-300A, O.C.V-65V D / C & A / C , Mma Electrode Size-2-4Mm., Tunsten Electrode Size-2Mm-3.15Mm. Type Of Control-Microprocessor Based Digital Soft Switch Control & Pwm , Up Slove / Down Slove Time-1-10Sec, Gas Pre Flow Time-1-10Sec, Type Of Cooling-Fan, Class Of Insulation-“F”, Mcb Rating-40Amps , Protection Class-Ip23, Weight Approxx-32Kgs., Should Have Welding Amps Digital Meter, Hot Start / Arc Force / Background Current Adjustment, 4T & 2T Switching Function, Tig & Mma Dual Functioned, Water Cooling Unit Inbuilt In Main Power Source , Machine Also Have Over Voltage, Phase Missing , Over Current And Over Heat Protection. Accessories List:- Copper 35Sqmm. Hofr Welding Cable -7.5Mtr.Copper 35Sqmm. Hofr Earth Cable-5Mtr. Water Cooled Gtaw Torch-01 Nos. Cooling Tour Machine. Crocodile Type Earth Clamp -01 Nos. Welding Full Helmet With Glass-01 Set.Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. Power Connection Cable 4Sqmm 4 Core -5Mtr. Tungten Electrode-2Mm, 2.5Mm & 3Mm -1Nos. Each, Argon Cylender-7Cum-01 Pcs. Argon Ssdg Regulator-01 Nos.Argon Flowmeter-01 Nos., Argon Transparent Nylon Hose Pipe-10Mtr.Argon Cylender Holding Stand, Torch Collet, Front Cap-05 Nos. Each. ( 05 Years Amc Required. ) 59 Appliances Refrigerator ( One Direct Cool & Other Frost Free Type ) Standard Quality 60 Solar Photovoltaic Inverter:5 Kva Solar Inverter 61 Sewing Kit ( Includes Thread Clipper / Hand Trimmer, Seam Ripper, Fabric Cutting Scissors, Tracing Wheel, Measuring Tape Etc ) 62 Pneumatic Tools For Motor Vehicles Standard Quality 63 Pipe Deburring Tool Standard Quality 64 Capillary 600 Standard Quality 65 Safety Hand-Gloves Standard Quality 66 Machine Tool Kit Standard Quality 67 2 Post Lift Standard Quality 68 Flairing Set Standard Quality 69 Brazing Rod+ Flux Sets Standard Quality 70 Safety Goggles Standard Quality 71 Machine Oil Standard Quality 72 Pullers Standard Quality 73 Pipe Expander Set Standard Quality 74 Screw Bits / Nut Driver ( 41 Piece Set ) Set Standard Quality 75 Safety Harness Standard Quality 76 Machine Needle And Hand Needles ( Various Gauges ) , Embroidery Needles Standard Quality 77 Steering Covers Standard Quality 78 Pipe Threader Set 10 Pcs Standard Quality 79 Testing Board ( Ref / Ac ) Set Standard Quality 80 Reflective Jacket Standard Quality 81 Needle Threader Standard Quality 82 Sun Glasses ( 3 M ) Standard Quality 83 Ratchet Type Pipe Threader Set 1 / 2, 3 / 4, 1 Set Of 3 Pcs Standard Quality 84 Tube Bender ( Mechanical / Tube ) Set Standard Quality 85 Attachments For Sewing Machine Heaming Foot Or Hemmer Foot, Embroidery Plate, Straight Stitch Throat Plate, Rubber, Zipper Foot, Straight Stitch Pressure Foot, Button Foot, Button Hole Stitch Foot 86 Torque Wrenches 5 - 35 Nm Standard Quality 87 Pipe Bender Spool Type Up To 25 Mm. With Stand Manually Operated. 88 Swaging Punch Set Standard Quality 89 Button Hole Scissor Standard Quality 90 Vehicle Safety Stands Standard Quality 91 Gate Valve , Ball Valve, Globe Valve Standard Quality 92 Copper Tube 1 / 2, 3 / 16, 1 / 4, 3 / 8, 5 / 8 ( Roll Set Each ) Standard Quality 93 Hand Notcher ( Pattern Notcher ) Standard Quality 94 Wheel Balancer 5-10 K.W Standard Quality 95 Couplings Standard Quality 96 Teflon Sheet 0.3Mm-6.5Mm Standard Quality 97 Sewing Threads Standard Quality 98 Pvc Pipe Cutter Standard Quality 99 T-Allen Key 2Mm-19Mm Standard Quality 100 Bobbins Standard Quality 101 Regular Plier Standard Quality 102 L-Allen Key 1.5Mm, 2Mm, 2.5Mm, 3Mm, 4Mm, 5Mm, 5.5Mm, 6Mm, 8Mm, 10Mm. Standard Quality 103 Design Softwares ( Coral, Photoshop Etc ) 104 A / C Machine ( 124 Robin Air ) Standard Quality 105 Mig Welding Machine Gmaw Welding Machine 400 A Capacity With Air Cooled Torch, Regulator, Gas Preheater, Gas Hose And Standard Accessoires, 415 Volt +- 10% Ac, Ac 3 Phase, 21.5 Kva, Vac 400-415, 50 / 60 Hz, Duty Cycled 60-100, Vdc Out 34 Vdc, Ocv High 62 Mic / Msg Accessories List:- 70Sqmm. Hofr Welding Cable -7.5Mtr. 70Sqmm. Hofr Earth Cable-5Mtr. Welding 400Amps Insulated Holder-01 Nos. Crocodile Type Earth Clamp-01 Nos. Welding Hand Screen With Glass-01 Set. Welding Cheeping Hammer-01 Nos. Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. ( 05 Years Amc Required. ) 106 Work Table ( 5X3x2.5 ) Standard Quality 107 Battery :Battery Type- Lmla / Vrla, Voltage-12 / 24 V, Ah Capacity- 65 / 100 / 150Ah, Container -Battery Rack, Cover- Polypropylene Copolymer ( Ppcp ) , Terminals- M, Electrolyte, Self Discharge-≤5% ( As Per Is13369≤10% ) In 28Days, Life Expectancy- 5 Years, Approval-Yes, Service Life-Minimum 5 Years, Ah Efficiency- Above 90%, Charge Efficiency- Above 80%, Maximum Depth Of Discharge ( Dod ) -0.9 108 Bobbin Case Standard Quality 109 Water Pump Plier Standard Quality 110 Nose / Combination Pliers ( Insulated 150 Mm ) , Tong Pliers 150 Mm 111 Hanger Wooden And Plastic Material 112 Combination Plier 200 Mm Standard Quality 113 Tube Cutter 100 Mm Standard Quality 114 Embroidery Frame 4’X6’, 3’X2’, 2’X2’ Standard Quality 115 Adjustable Wrench 6” Standard Quality 116 Wire Brush Standard Quality 117 Fabric Yardages, Surplus Fabric, Good Quaity Muslin Mandatory 45 Mtr Each 118 Adjustable Pipe Wrench 8” Standard Quality 119 Paint Brush ( 50 Mm ) Standard Quality 120 Trim / Accessory Buttons, Surface Embelishments, Zippers 2 Dozen Each Standard Quality 121 H Eavy Duty Pipe Wrench 300 Mm Standard Quality 122 Hammer Ball Pin 500 Gms Standard Quality 123 Pin Cushion Standard Quality 124 Pipe Wrench Chain Type Standard Quality 125 Monkey / Adjustable Plier 20 Mm Standard Quality 126 Dustbin Standard Quality 127 Aluminium Pipe Wrench 450 Mm Standard Quality 128 Fixed Spanner ( 10-11, 14-15, 16-17 Each ) Standard Quality 129 Boxes And Pouches For Storing Items Standard Quality 130 Hammer Type Screw Driver 100-250 Mm Standard Quality 131 Neon Phase Tester ( Insulated 150 Mm ) Standard Quality 132 Pattern Table / Cutting Table Standard Quality 133 Screw Drivers 200 Mm Standard Quality 134 Round File ( Smooth 150 Mm ) Standard Quality 135 Stools For Cutting Standard Quality 136 Screw Drivers Insulated Type 150 Mm 137 Flat File ( Smooth 200 Mm ) Standard Quality 138 Printer Multipurpose 139 Air Compressor 50 Ltr. Standard Quality 140 Electrofusion Welding Machine Hdpe Electrofusion Welding Machine , 20 To 315 Mm Accessories List:- 70Sqmm. Hofr Welding Cable -7.5Mtr. 70Sqmm. Hofr Earth Cable-5Mtr. Welding 400Amps Insulated Holder-01 Nos. Crocodile Type Earth Clamp-01 Nos. Welding Hand Screen With Glass-01 Set. Welding Cheeping Hammer-01 Nos. Wire Brush-01 Nos. Lather Hand Gloves-01 Pair. ( 05 Years Amc Required. ) 141 Bins For Tools Standard Quality 142 Clampmeter 0 - 100 A ( Digital Type ) . 143 Students Chair ( With Table Arm ) Standard Quality 144 Screw Driver Bit Set Of 10 Pcs Standard Quality 145 Hacksaw With Blade ( 150-200 Mm ) Standard Quality 146 Teachers Table Standard Quality 147 Open Spanners De Set Of 10 Standard Quality 148 Long Screw Driver ( 250 Mm ) Standard Quality 149 Teachers Chair Standard Quality 150 Ring Spanners Set Of 10 Standard Quality 151 Tommy ( Mini 0 Screw Driver-Flat Head ( 550 Mm Tip ) ) Standard Quality 152 Push Pins Standard Quality 153 Double Ended Spanners Set Of 10 Standard Quality 154 Fire Extinguisher ( Abc Powder Type 2 Kg ) Standard Quality 155 Dress Makers Pin Standard Quality 156 Adjustable Spanners 6” Standard Quality 157 Fuse Standard Quality 158 Fabric Pins Standard Quality 159 Ratchet Type Spanners 12 - 16 Mm Standard Quality 160 Compressor Relay Standard Quality 161 Highlighter Standard Quality 162 Tubular Box Type Spanners Set Of 12 Standard Quality 163 Freezer Thermostat Standard Quality 164 Pencil ( Hb, 2B, H, 2H, 4H, 4B, 6B, 8B ) Standard Quality 165 Bolt Cutters Standard Quality 166 Defrost Timer Standard Quality 167 Eraser Standard Quality 168 Hammers 1Kg 169 Megger Standard Quality 170 Note Books Standard Quality 171 Soft Hammers Standard Quality 172 Watt Meter Standard Quality 173 Photocopier Standard Quality 174 Battery Charger ( For 6V, 12V, V24v Battery ) 175 Pipe Cutter Machine Disc Diameter : 355 Mm ( 14 ) Cutting Capacity ( Square Bar ) : 119 X 119 Mm Cutting Capacity ( Round Pipe ) : 129 Mm No Load Speed : 3800 Rpm Power Input : 2200 W 176 First -Aid Box With All Material Standard Quality 177 Multimeter Dc 200Mv -1000V, 0 – 10A & Ac 200Mv- 750V , 0-10A, Resistance 0- 20 Mω And 3 1 / 2 Digit. 178 Sharpener Standard Quality 179 Allen Key Set 1.5 -10 Mm Standard Quality 180 Digital Clamp Meter 115 Amp Standard Quality 181 Carbon Paper ( Various Colours ) Standard Quality 182 Cold Chisel Standard Quality 183 Digital Thermometer Standard Quality 184 Design Transferring Paper Standard Quality 185 Steel Rules Standard Quality 186 Measuring Tape ( 5 Mtrs ) Standard Quality 187 Paper Cutter Standard Quality 188 12” Hack Saw Frame With Blade Standard Quality 189 Pressure Guage Standard Quality 190 Pattern Drafting Paper Standard Quality 191 Punch Centre , 150 Mm X 9 Mm Standard Quality 192 Compound Guage Standard Quality 193 Paper ( Various Quality And Sizes ) Standard Quality 194 Try Square 10 Cm Blade Standard Quality 195 Capilary Guage Standard Quality 196 Labels & Stickersstandard Quality 197 Crow Bar Standard Quality 198 Scissors ( Plastic Handled Scissor For Cutting Paper ) 199 Lever Bar Standard Quality 200 Pinking Shears Standard Quality 201 Full Harness- ( Half Body ) Standard Quality 202 Marking Chalk ( Yellow / Pink / Green / Blue Coloured ) 203 Full Harness- ( Full Body ) Standard Quality 204 Projector Dlp Hd Celing Mounted 3500 Lumens 205 Bc Clamp Meter Standard Quality 206 Fume Extractor Standard Quality 207 Service Manual / User Manuals ( Each ) Standard Quality 208 Earth Tester Analog - 500 V. 209 Tailor’S Chalk Standard Quality 210 Ladder Hook Standard Quality 211 Carbon Paper ( A4, Yellow, Red And White Carbon ) 212 Asbestos Hand Gloves Standard Quality 213 Colour ( Poster Colour, Water Colour, Acrylics, Pastels, Fabric Printing Dyes And Colors And Materials Etc ) 214 Blue Aprone Standard Quality 215 Paint Brushes ( Different Sizes ) Standard Quality 216 Leather Jacket Standard Quality 217 Stapler ( Small And Big Size ) Standard Quality 218 Welding Gloves Standard Quality 219 Glue Stick / Fevicol / Adhesive Standard Quality 220 Hand Sleeve Standard Quality 221 Fabric Glue Standard Quality 222 Leg Guard Standard Quality 223 Cello-Tape ( Transparent And Foam Double Sided Tapes, Single Sided Tapes ) 224 Ear Plug Standard Quality 225 Punching Machine Standard Quality 226 Cutting Goggles Standard Quality 227 Magnetic White Board / Black Board Eraser Standard Quality 228 Welding Goggles ( Black ) Standard Quality 229 Mannequin Lady, Men, Kid ( Boy & Girl ) Standard Quality 230 Bench Grinder Standard Quality 231 Power Hacksaw Hydraulic Feed System 400 Mm. Blade Size, Motor Capacity -0.75 Kw 232 Personal Protection Equipment Standard Quality 233 Spirit Level 30 Cm Standard Quality 234 Blackboard & Whiteboard 900X600 Mm 235 Nose Mask Standard Quality 236 White / Blackboard Marker Standard Quality 237 Welding Hand Screen ( Shield ) Standard Quality 238 Pantone Shade Card Standard Quality 239 Welding Head Helmet ( Shield ) Standard Quality 240 Auto Darkening Helmet Standard Quality 241 Buyer Requirement / Comment Sheet Standard Quality 242 Electrical Hand Gloves Standard Quality 243 Measurement Sheet / Size Chart Standard Quality 244 Operator Gloves Standard Quality 245 Trims / Accessory / Fabric And Embroideries Samples / Swatch File Standard Quality 246 Tech Pack / Specification Sheet Standard Quality 247 Chalk &Marker ( Chalks & Markers Of Different Colours ) Standard Quality 248 Dexterity Test Kit Standard Quality 249 Power Operated Sewing Machine2000-3000 Stitch / Min With Table 250 Car Seat Covers Standard Quality 251 Bench Drilling Machine Drilling Machine Bench Input Power : 680 Watt, Max. Drilling Capacity : 12Mm, Spindle Travel: 60Mm, Working Radius: 143Mm, Working Size : 205X205mm, Column Size: 45X500mm. 252 Brazing Kit ( 1 Swirl Type ) Standard Quality 253 Pyranometer Standard Quality 254 Sewing Machine Tool Kit Standard Quality 255 Color Matching Light Box Standard Quality 256 Students Notes Standard Quality 257 Stools For Sewing Depending On No. Of Machines Standard Quality 258 Cotton Gloves Standard Quality 259 Rotary Type Drilling Machine 750 Watt 260 Male - Female Couplers  Standard Quality 261 Heavy Duty Rotary Type Hammer Drill Machine 20 Mm ( 05 Years Amc Required. )
Contract Date: Nov 18, 2021 Contract Value : 71.87 Lakh
Government Departments No of Bidders 9
West Bengal View Result →
25.
Public Administrative Department #1341794 AOC
Amc Of Airconditioners Guruvayur Devaswom Providing Annual Maintenance Contract ( Amc ) Of Various Split Air Conditioners Belong To Guruvayur Devaswom Premises , Ac Amc , Providing Annual Maintenance For Split A/Cs At Guruvayur Devaswom Buildings As Per The Conditions Mentioned Below ( Charges Without Spares ) . The Rate Of Spare Parts Will Be Paid By Guruvayur Devaswom-The Tender Should Attach The Price List For Materials Separately As Per The List Attached- 1-All Inclusive Annual Maintenance Services Shall Include Providing Routine Maintenance Services . 2-Amc Providing All Man Power , Tools And Tackles And Replacement Charges Of Defective Parts . 3-The Contractor Should Attend Any Type Of Breakdown Problems Within 12Hrs After Registering Complaint At Free Of Cost . 4-Price Inclusive Of All Labor Charges For Replacements And Repairing Charges 5-The Contractor Should Provide A Standby Arrangements When They Failed To Repair The Machine Within 48Hrs . ( Should Provide Price List Of Essential Part ( S ) Along With Hard Copy Of Tender Documents ) Routine Amc Service Following Services Including In The Routine Maintenance ( Quarterly Service ) 1-Cleaning/Replacement Of Filter 2-Checking Operation Of The Control Of The Air Conditioners Such As Thermostat , Relays , Remote Control Etc . 3-Checking Of The All Electrical Parts 4-Checking Operation Of The Drive Motors And Fan 5-Checking Firmness Of The Supporting Arrangement Of The Compressor , Blower , Motor , Air Conditioners Casing And Fixing Of The Air Conditioner 6-Topup Gas If It Required 7-Replacement Of Defective Components After Above Check And Tests . 8-Cleaning The Condenser And Evaporator Coils With Suitable Chemical Solution / Flushing With High Pressure Jet Of Water ( Which Is Necessary )
Contract Date: Jan 25, 2022 Contract Value : 2.12 Lakh
Trust & NGO No of Bidders 2
26.
Educational and Research Institute #1180200 AOC
Supply Of Laboratory Equipments Physics , Botany , Zoology Departments - 2 Ammeter ( A, Ma, Micro A ) Nmoving Coil Type For Dc Measurements, Nrange: 0 To 500 Micro-Ampere, 0 To 50 Ma, 0 To 100 Ma, 0 To 250 Ma, 0 To 500 Ma 0-1 Ampere, 0-5 Ampere. Table Top, The Moving Coil Mechanism Should Be Adjustable For Zero, 4 Mm Sockets For Electrical Connection. Two Year Minimum Warranty 3 Bread Board Nhigh Quality Nickel Plated Bread Board Or Solderless Pieces; Dual Bus Strips Non Both Sides, With 630 Tie Point In Terminal Strip & 200 N Tie Point In Distribution Strip. 4 Calorimeter Ncalorimeter With Double-Walled Glass Jacket, Highly Evacuated, Silver-Coated On The Inside, In Plastic Casing. 5 Capillary Tube Ncapillary Tubes Of 6 Different Bore Diameters, 15Cm Long 6 Carey Fosters Bridge Nteak Base – 99.9% Copper Strip – Soldered Joints – Non Corrosive With Jockey, Standard Resistance Suitable For The Experiment. ( 1 Ohm / 2 Ohm ) 2 Nos Each, Standard Resistance Wire Eureka ( 100Gm ) . Minimum Two Year Warranty 7 Circuit Board Ncircuit Board- For Soldering Experiment 8 Circular Coil Apparatus Nteak Wood Base - 75Cm Long With N15 Cm Dia Coil And Slides On Base With 20, 30, 50 And Total 100 Turns And Superior Quality Compass Box - Aligned Exactly 0-0 And Permanent Magnet With Alnico Bar Magnet. Minimum Two Year Warranty 9 Commutator Ncommutator With Terminals For Electrical Experiments, On Nicely Polished Wooden Nbase With Sunmica Top 10 Good Quality Sensitive Compass Box With Anti Parallax Mirror With Npermenant Magnet And Stone Agate Bearing Needle; Minimum Two Years Warranty 11 Compound Bar Pendulum Ncompound Pendulum On Stand With Photo Gated Digital Stop Clock; With Wall Mount, Removable N Knife Edge, Including Fixing Charge 12 Cotton / Cloth Covered Single Stand Copper Wire Ndcc Wire High Class Double Cotton Wire Generally Used In Nlab For Connections - 100Gm Coil 13 Cro Probes Ngood Quality Cro Probes, Bnc Mail / Crocodile Clipcord With 1:1 Attenuation 14 Daniel Cell ( Electrical ) Nelectrical Daniel Cell 1.08 V Dc Output 15 Defelction Magnetometer Ndefelction Magnetometer 16 Desoldering Pump Ngood Quality Desoldering Pump For Electronics Experiments 17 Digital Multimeter Ngood Quality Handheld Digital Multimeter - True Rms Measurement; Minimum Two Years Warranty 18 Digital Screw Gauge Ngood Quality Micrometer Screw Gauge - Digital N25mm, 0.001Mm Resolution, 0.002Mm Naccuracy, Nn / Inch Unit, On / Off Button, Lock / Unlock Nswitch With Two Year Warranty 19 Digital Vernier Calpers Ndigital Vernier Callipers, Digital Numbers, 6 ( 150Mm ) N Size, Large Display, On / Off Switch 20 Digitalthermometer Ngood Quality Non Contact Thermo Meter, With Builtin N Laser Pointer, Resolution 0.1 Deg C, Automatic Data Hold Nand Auto Power Off, Lcd Display; Minimum Two Years Warranty 21 Electric Generator Nsinge Phase Output 3 Kva Or More, 230V / 50 Hz, Minimum Rated Output 2800 Va, Air Cooled Engine Type, Load Sensitive, Engine Electronic, Governor, Auto Choke, Monitor Equipped Engine Control Panel Display, Starting - Electric / Recoil Start, Fuel Type, Petrol, Continuous Operating Hours - 6 Or More., Oil Alert System, Ac Circuit Protector N 22 Electric Heater Nelectric Heater- ( Hot Plate- Rounde ) . Minimum Two Year Warranty 23 Electronic Balance Nmaximum Capacity: 300G Or Better, Reading Precision:90Mm, Automatic External Calibration, Glass Windscreen, 6 Digit Lcd Display, Display Back Light, Overload Protection, Built-In Interface For Direct Connection To Pc Or Printer, With A Spirit Level, Corners Leveling; Minimum Two Years Warranty 24 Fly Wheel Ngood Quality 8 Size Flywheel; Nincluding Fitting Charge; Minimum Two Year Warranty 25 Glass Beakers Ngood Quality Glass Beaker Graduated 500Ml 26 Glass Jar ( 1L ) N1 L Glass Jar 27 Glass Rods Nglass Rods For Stirring 28 Gycerine ( 100 Ml ) Nlab Grade Glycerine 29 Hares Apparatus Nwith Wooden Stand And Borosilicate Glass Tube 30 High Resistance Nhigh Resistance, With Plug Type Short Circuit Key Fitted On Nnicely Polished Teak Wood Case Values 1K Ohm, 2K Ohm, 5K Ohm, 10K Ohm 31 Induction Coil N20 Mm Induction Coil, Made With Best Quality Copper Wire N& Paraffin Wax Insulation, Fitted With Platinum Ncontacts, Workable On 4-6 Volts D.C At 3 Amps, Complete Nwith Removable Spark Discharger 32 Jockey Njockey, With Brass Cp Point; Lock Type Terminal 33 Katers Pendulum With Knife Edge Nkaters Reversible Pendulum Bar With Wall Bracket & Nknife Edge, Made In Iron Rod 34 Knife Edges, For Young’S Modulus Experiments Ngood Quality Bending Stand / Knife Edge Metal With Nheight And Level Adjustment For Young’S Modulus Nexperiments 35 Kundts Tube Apparatus Nkundts Tube Apparatus Including Glass Tube, Speaker, Nsupports, Powersupply For Amplifier, Audio Amplifier Netc. Without Function Generator 36 Leadshots 500G 37 Lees Disc Apparatus Nlees Disc Apparatus With Steam Chamber And Heater 38 Meldes String Apparatus With Scale Pan Nhigh Quality Meldies String - Frequency Of Fork Apparatus Nheavy Pattern, Having Transverse And Longitudinal Nmotion, Minimum 2 Year Warranty 39 Mercury 500 G 40 Mercury Vapour Lamp ( Lamp Only ) 41 Metal Pointers 42 Modem-Wifi Router Nmirror Strips For Bending Experiments 43 Gigabit Mu-Mimo Wireless Router, Dual Band 1200 Mbps Wi-Fi Speed, 5 Gigabit Ports, 4 External Antennas And 1 Internal Antenna Wifi Coverage With Access Point Mode, Qualcomm Chipset 44 Multi Purpose Stands And Holder Nmultipurpose Stands And Holder- Tripod Stand And N Universal Clamp For General Lab Use 45 Newton’S Law Of Cooling Apparatus 46 Oil Bath 200Mm Inner Dimension 2Ltr Capacity, 1500W 47 Optic Lever With Clamp And Holder To Hold Telescope N Bakelite Base N 48 Plane Mirror 49 Potentiometer Non Heavy Teak Base With Glass Top And Bakelite End, 10M Wires Soldered At Ends, Strips Are Of Pure Copper Np ( 99.9% ) With Pencil Jockey. Accuracy Guaranteed, Minimum 2 Years Warranty 50 Power Supply ( Dual ) Nhigh Quality Dual Power Supply 0- 30V / 2A; Dual Ncontinuously Variable With Course And Fine Controls; With Noutput Short Circuit Protection; Indication For Short Circuit, N16x2 Lcd Display; Full Nmetal Body With Powder Coating; Thrmal N Shutdown; Reverse Voltage Protection; Minimum Five Year Ns Warranty 51 Power Supply ( Normal ) Nhigh Quality Single Variable Power Supply 0-32V; Continuously Variable With Course And Fine Controls; 2A Output Current; Lcd Display; Overload / Short Circuit Protection With Led And Beep Indications; Reverse Voltage Protection, Themal Shutdown; Minimum 5 Years Warranty 52 Printer ( Laser ) Nmono Multi-Function Laser Wi-Fi Printer: All-In-One ( Print, Scan, Copy ) Mono ( Black ) ; Connectivity- Usb 2.0, Wi-Fi, Network.; Pages Per Minute -Up To 27Ppm ( A4 ) ; Auto Duplex; Monthly Duty Cycle- 15000 Pages; Page Size Supported-A4, B5, A5, Legal, Letter, Statement, Executive, Government Letter, Government Legal, Foolscap, Indian Legal Custom ( Minimum 76.2 X 210Mm To Maximum 216 X 356Mm ) ; Print Resolution - 600 X 600Dpi 53 Quartz Prism ( 25X25 ) 54 Probes Nmultipurpsoe Probes - Cro / Function Generator, Etc. 55 Reading Lens ( Simple Microscope ) Nhandheld Big Magnifying Glass With Led Lights Glass Magnifier For Reading; Magnification: 1.8X / 5X 56 Resistance Coil- Temperature Coefficient Expt Nresistance Coil For Temperature Coefficient Expt, The Coil Nwounded On A Thermometer, Imerged In A Test Tube Filled Nwith Oil, Provided With Bti-15 Terminal For External Nconnection 57 Resistance Wire 10 M Neureka / Constantan Wire With 22 / 24 / 26 / Ngauge In 100Gm Coil 58 Rheostat N6 Inch Rheostat; Insulating Porcelain Tube Wound With Heavily Oxidised Eureka Wire; Heavy Aluminium Feet Duly Powder Coated With Rod And Brass Nuts; Minimum Two Years Warranty 59 Scale And Telescope Apparatus Ngood Quality Lamp And Scale Arrangement Fitted With Nled Light 60 Signal / Function Generator Nhigh Quality Function Generator With Frequency Ranges From 0.5 Hz To 5Mhz, Sine, Square, Triangle Output Wave Forms With Dc Offset. Amplitude From 20Mv To 20Vpp In Three Ranges. Capacitive Feather Touch Switch And Output Short Circuit Protection; Minimum Five Years Warranty 61 Sodium Vapour Lamp Nhigh Quality Sodium Vapour Lamp In Corrosion Free Nmetal Cabinet With N Adjustable Slits In Three Sides. 35W With Built In N Power Supply. Minimum 5 Year Warranty 62 Soldering Iron N 35 W Soldering Iron With Minimum 2 Years Warranty 63 Soldering Lead 500 G Nlead Free Solder Wire 500 G 64 Soldering Wax 500G Nsoldering Paste ( Flux ) 65 Sonometer, For Measuring Frequency Of Ac Nhigh Quality Ac Sonometer In Teak Ply With Brass Fittings , 6V / 2A Power Supply With Electromagnet And Stand For Electromagnet; Minimum Two Years Warranty 66 Standard Resistance Ngood Quality Standard Resistance Fitted In Aluminium Or N Steel Turf And Bakelite Case With 2 Terminals Nmanganin Coil – Calibrated Accuracy 0.1% With Two Terminals 1 67 Standard Resistance Boxes Nrange: 1-10000 Ohms Nenclosed In Polished Teak Wood Box With Bakelite Panel. Split Brass Contact Blocks Hold Precision Cut, Interchangeable Plug Having Moulded Black Bakelite Fluted Tops. Coils Of Constantine Wire, Double Silk Covered Are Wound. Coils Connected With Double Nut System. 68 Stands For Torsion Pendulum Ngood Quality Desktop Type Stand For Torsion Pendulam With Firm Base 69 Static Torsion Apparatus Ngood Quality Static Torsion Apparatus, Horizontal N Platform, 1 Mtr 3 Scale, Including Weight, Minimum Two Years Warranty 70 Steam Generator Nsteam Generator - Electric Heater And Pressure Cooker 71 Step Down Transformer Nstep Down Transformer 6-0-6 / 9-0-9 / 12-0-12; 1A Fixed N With Terminals, Short Circuit Protected, With Illuminated N On / Off Switch And Power Chord Case; Minimum Two Years Nwarrranty 72 Stop Watch, Battery Type Ngood Quality Digital Stop Watch With Large Display, Two N Aaa Battery Powered, Auto Power Off; Minimum 2 Years Warranty 73 Stop Watch, Winding Type Ngood Quality Mechanical Stop Watch, Winding Type, Start- Nstop & Fly Back Action In Metal Body White Powder N Coated 74 Table Lamp Ndesk Lamp Study Reading Rechargeable Led Table Lamps Usb Charging Touch Dimmer With 1 Battery 75 Table Model Moving Coil Galvanometer Nmoving Coil Dc Galvanometer, Scale 30-0-30, The Moving Coil Mechanism Should Be Adjustable For Zero, 4 Mm Sockets For Electrical Connection; Minimum Two Years Warranty 76 Tangent Galvanometer Ngood Quality Tangent Galvanometer With Two Years Warranty 77 Test Tube Nlaboratory Test Tube - 18X150 Mm Round Bottom 78 Thermometer Nlaboratory Thermometer ( Mercury Filled 300Mm / 300°F ) 79 Torsion Pedulum, With Nichrome Wire Ntorsion Pedulum Apparatus ( 5 Disc ) With Nichrome Wire 80 Torsion Pendulum-Wire 10M Nnichrome Wire For Torsion Pendulum Experiment 10M Long 81 Travelling Microscope Nbase : Iron; Scale : Stainless Steel Nvertical Scale - Main Scale : 0-150Mm; Vernier Scale : 0-1Mm; Least Count : 0.01Mm Nhorizontal Scale - Main Scale : 0-180Mm; Vernier Scale : 0-1Mm; Least Count : 0.01Mm Neyepiece : 10X ( Ramsden ) ; Magnifying Lens For Reading; Rack And Pinion Arrangement Focusing; Wide Aperture Optics; Accurate And Precise Arrangement; Minimum Two Years Warranty 82 Ups, And Battery For The Whole Lab Noutput Power Capacity 3.5Kwatts / 5.0Kva, Input Frequency 50 / 60 Hz + / - 5 Hz ( Auto Sensing ) Nominal Input Voltage 230V Nominal Output Voltage 230V, Waveform Type Sine Wave, 2 Years Onsite Warranty, Remote Power Management Of The Ups Over The Network, Generator Compatible, User-Replaceable Batteries, Efficiency At Full Load 92.0 % Or Greater, Output Voltage Distortion Less Than 3%; Minimum Two Years Warranty 83 Vibration Magnetometer ( Box Type ) Nhigh Quality Box Type Vibration Magnetometer In Teak Wood 84 Vibration Magnetometer ( Searles ) Nsearle’S Magnetic Needle In Sealed Glass Jar, Terminal Is Provided To Adjust The Length Of The Thread 85 Volt Meter ( Various Ranges ) Ndigital Voltmeter, With 4 Selectable Range ( 200V, 20V, 2V, 200Mv ) Using Rotary Switch; 7 Segment Display With Polarity Indication, 230V 50Hz Operating Voltage, 1 Microv Resolution, Powder Coted Metal Cabinet, Banana To Crocodile Connector Pair, Standard Test Leads, Usefull For All Laboratary Expreriment, Miniumum Five Years Warranty. 86 Voltage Source ( Variable ) Nhigh Quality Single Variable Power Supply; 0-32V Continuously Variable; 2A Output Current; Lcd Display; Overload / Short Circuit Protection With Led And Beep Indications; Reverse Nvoltage Protection; Themal Shutdown; Minimum Five Years Warranty 87 50 Mhz Digital Storage Oscilloscope Ndigital Storage Oscilloscope; 2 Channel 50 Mhz Bandwidth; 5.7Tft Color Display, Usb Port For Pc Interface, 250Msa / S Real- Time And 25Gsa / S Equivalent-Time Sampling, Data Logger; Minimum Five Year Warranty. 88 Variac Dimmerstat Nvariac / Dimmerstat / Auto Transformer ; Portable ( Close ) Type 1Phase 0 To 270V Ac / 4A Or Greater ( Table Top Model ) 89 Bosch Hand Tool Kit Ntool Box With 1-Piece Screwdriver, 1-Piece Hammer, 7-Pieces Screwdriver Bits, 1-Piece Plier, 1-Piece Wrench And 1-Piece Measuring Tape 90 Botany 91 Autoclave Nchamber Volume ( Total / Nominal ) - 24-35 L; Model - Fully Automatic; Timer - Yes ( Enabled ) ;Sterilization Class -Class N, Sterilization Temp -121 Degrees;134 Degrees; Drying Procedure - Heating Dry, Display -Led Display; Control Precision -Temp -1 Degree; Pressure-0.1 Bar, Safety System -Hand Lock Door;Relief Valve In Case Of Over Pressure; Pressure Or Temperature Over Load Protection; Alarm For System Failure; Finish Remaining Tray Holder - 3Pieces Ss Trays On Ss Shelves;Chamber -Ss 304 Unibody Structure;Max.Working Pressure:2.3Bar; Min.Working Pressure:1.1 Bar; Max.Temp:145 Degrees;Ambient Temp -5-40 Degrees;Noise 92 Cooling Centrifuge ( Table Top Ncontrol - Microprocessor With Variable Frequency Drive, Max. Speed- >14000 Rpm, Brushless Induction Motor, Digital Lcd Display, User Defined Rpm / Rcf, Acceleration, Deceleration, Timer & Temperature With >25 Programs, Acceleration / Deceleration 12 - 510 Secs, Timer 1-120 Min, Dynamic Brake, Cfc Free Cooling -20 To +40, Safety - Centrifuging Chamber Stainless Steel. Powered Lid Locking. Pre- Cooling Function ( Fast Cool ) And Stand-By Cooling, Lid Lock & Imbalance Protection, Gas Spring, Power Supply - 230V, 50 Hz. Rotor Heads : 8 X 50Ml, 12 X 15 Ml, 24 X 1.5 / 2.0 Ml 93 Deep Freezer - 20 Nhorizontal / Vertical Deep Freezer. Temperature Range 25°C To -20°C ; Direct Cooling Type; Microprocessor Controlled System. ; Capacity 300 Lit Or Above; Led Display; Cfc- Free Refrigerant. ; Noise Level Less Than 45 Db. ; Alarms For Systems Malfunction Over And Under Temperature & Sensor Error; Equipment Should Ce Certified / Indian Standard Certification. ; Warranty Period To Be Mentioned ; Amc Charges To Be Indicated 94 Electronic Balance 4 Digit Naccuracy 0.1 Mg Capacity 0.1 Mg To 230 Gm Pan Size 90 Mm Calibration Internal Display Lcd With Back Light 95 Electrophoresis - Age With Power Pack And Accessories Nvertical Electrophoresis System 1 No. Number Of Gels - 2 Gels, Gel Size ( W X L ) - 8.3 X 7.3 Cm, Should Have Sample Loading Guide For Easy Loading Of Samples, Casting Frames With Simple Camclosure For Providing Precise Alignment On Any Flat Surface, Side-By –Side Casting Stand, Suitable Plastic Combs Should Be Supplied With Sds Page Starter Kit , Protein Marker And Other Necessary Consumables. Mini Horizontal Electrophoresis System 1 No Size Of 7X10cm With Safety Lid With Sample Throughput Of 8-30 Uv Transparent Gel Tray Of Size 7X 7 With Integrated Fluorescent Ruler. Tape Free Gel Casting Module For Leak Free Operations. A System Should Include Two 1.5Mm 8- & 15-Well Fixed Height Combs. Option For Adjustable Height Combs With Comb Holders. Power Supply Output Range ( Programmable ) : 10–300 V, Fully Adjustable In 1 V Steps 4–400 Ma, Fully Adjustable In 1 Ma Steps 75 W Maximum Type Of Output: Constant Voltage, Constant Current With Automatic Crossover Output Terminals: 4 Pair Recessed Banana Jacks Floating In Parallel Timer: 1–999 Min, Fully Adjustable Pause / Resume Run Function Operating Conditions: 0–40°C; 0–95% Humidity In The Absence Of Condensation, Overload / Short Circuit Protection, Input Line Protection, Auto Power-Up After Power Failure Input Protection: Fuse On Both Hot And Neutral Input Power ( Actual ) : 198–264 Vac, 50 Or 60 Hz 96 Uv Transilluminator Nimported. Gels Stained With Both Ethidium Bromide And Sybr® Green Could Be Viewed On A Background Free Transilluminator With The Naked Eye More Easily. The Long Life Filter Should Provides A High-Contrast Background, Enabling Viewing Of Even The Faintest Bands. Filter Frame Made Of High-Quality Stainless-Steel. The Body Should Be Epoxy Painted And Resistant To The Chemicals And Unit Designed Prevents Liquids From Leaking In To The Interior. 97 Ph Meter Nmeasurement Ph & Orp Display 31 / 2 Digit Led Range Resolution 0 -14.00 Ph 0 ± 1999 Mv 0.01 Ph, 1Mv Accuracy + 0.01 Ph, + 1Mv Temperature Compensation Auto + Manual 0To100°C Slope Control 80 To 120% 98 Zoology 99 Class Abc ( Dry ) Fire Extinguishers 100 Class B Carbon Dioxide Type Fire Extinguishers 101 First Aid Kit 102 Fire Blankets 103 Fume Hood 104 Microwave Oven 30 Littre 105 Laminar Flow Type-Vertical, Material-Aluminium, Ss, Ms, Surface Finish-Polished, Usage / Industry Nnoise Level-55 Db + / - 5, Phase-Single, Air Balancing-100% Filter Air At Working Area, Average Velocity-0.46 M / S, Supply Hepa Filter-0.3 Micron Ulpa Filter, Efficiency 99.997%, Pressure Drop-15Mm, Pre Filter-10-15 Micron, Efficiency 90%, Control Systems-Feather Tough On / Off Control, Voltage-230 V, Frequency-50 Hz 106 Hot Air Oven Bottom Heated, Temperature From Ambient +5°C Up To 250°C, Thermostatic Control With A Accuracy Of +1°C, Double Walled Inside Aluminum / Stainless Steel And Outer Made Of Mild Steel Beautifully Powder Coated.To Work On 220 / 230 Volts. A.C Supplied With Or Without Air Circulating Fan With Thermometer 107 Bacterial Incubator Temperature Range From Ambient +3°C To 60°C, Microprocessor Pid Control / Temperature Calibration / Automatic Tuning. Free From Noise, Vibration, And Mechanical Troubles By Film Type Heating Method, Ntuitive Control Panel With Bright Led Display. ( 0.1?Resolution ) , Dual Wait On / Off Timer Modes. ( 1 Min. To 99 Hr. 59 Min. ) , Convenient Preset Function For 3 Most Commonly Used Temperature Settings.Convenient Sample Monitoring Without Affecting Chamber Temperature Via The Inner Tempered-Glass Door.Rounded Inner Chamber Corners For Easy Cleaning And Optimal Airflow.Stackable Up To 2 Units Using The Optional Stacking Kit 108 Autoclave Material-Stainless Steel, Voltage 230V, Gasket-Neoprene, Heat Load-2.0 Kw, Chamber Wall-Single, Exhaust Valve, Pressure Gauge-0-2.1Kgf / Cm2, Sterilizing Pressure-0-2.1Kgf / Cm2 At 121 Degree Celcius, Aluminium / Stainless Steel, Frequency-50-60Hz 109 Colony Counter 110 Ultracentrifuge 111 Micro Centrifuge 112 Magnetic Stirrer Nmaximum Stirring Speed-1200 Rpm With Stepless Speed Control And Good Speed Stability , Heating Capacity - 600W , Hotplate Size -175Mm Dia, Supply – 220 / 240V, 50Hz, A.C, Hotplate-Should Be Chemically Resistant To Acid And Alkali , Top Plate Material – Stainless Steel , Stirring Unit – Should Be Enclosed So That Corrosive Fumes Do Not Enter It, Controls For Both Hotplate And Stirrer Should Be Provided With Suitable Indicators 113 Haemoglobinometer -Box 114 Haemocytometer -Box 115 Digital Ph Meter 116 Page Apparatus 117 Heating Mantles 118 Hot Plate / Induction Top 119 Digital Microscope 120 Dissection Microscope Nheavy Round Base , Sensitive Focusing By Rack-Pinion Movement, A Joint Revolving Arm, Replaceable Bya Special Bulls Eye Lens ( 83Mrndia. ) , A Plano-Concave Mirror , Detachable Hand Rests On Both Sides, Provided With L0x & 20X Eye Pieces And Special Bulls Eye Lens ( 83Mm Dia. ) .
Contract Date: Mar 12, 2021 Contract Value : 15.67 Lakh
Government Departments No of Bidders 8
TenderDetail
Loading tenders