Repairing Of 532 Units Quarters At Staff’S Colony, SurrenderColony & Surgujja (Bhutgoria) Colony Situated On Non-Coal Bearing Areas Under Pb Area, Bccl.-1 6 Mm Cement Plaster Of Mix : 1:3 (1 Cement : 3 Fine Sand)2 12 Mm Cement Plaster Of Mix : 1:6 (1 Cement: 6 FineSand)3 12 Mm Cement Plaster Finished With A Floating Coat Of 10 Providing And Fixing 1 Mm Thick Ms Sheet WindowShutter Made Of 30X30x5 Mm Angle Iron And ShutterFrame Made Of 30X30x5 Mm Angle Iron Front Side 3 Nos.Horizontal Braced With 20X5 Mm Ms Flat And 1 No. BackSide With Tie On Bottom Door Frame And 2 Nos. DiagonalBraced Back Side With 20X5 Mmm Ms Flat, 6 Nos. HoldFast With 20X5 Mm Ms Flat, Hinges Made Of 3 Nos. MsSheet 3 Mm Thick With Pin 6 Mm Dia. 120 Mm WeldedWith Shutter, 2 Nos. Sliding Door Bolts (250 X 16 Mm), 2Nos. 250 Mm X 10 Mm Ms Tower Bolt And 2 Nos. Handles125 Mm Including Primer Etc. Complete Job. Single Leaf.11 Providing And Fixing To Existing Door Frames. 24 MmThick Factory Made Pvc Door Shutters Made Of StylesandRails Of A Upvc Hollow Section Of Size 59X24 Mm AndWallthickness 2 Mm (± 0.2 Mm) With Inbuilt Edging OnBoth Sides.The Styles And Rails Mitred And Joint At TheCorners By Meansof M.S. Galvanised/Plastic Brackets OfSize 75X220 Mm Havingwall Thickness 1.0 Mm AndStainless Steel Screws. The Stylesof The Shutter ReinforcedBy Inserting Galvanised M.S. Tube Ofsize 20X20 Mm And 1Mm (± 0.1 Mm) Wall Thickness. Thelock Rail Made Up OfH Section, A Upvc Hollow Section Of Size100x24 MmAnd 2 Mm (± 0.2 Mm) Wall Thickness, Fixed To TheshutterStyles By Means Of Plastic/Galvanised M.S. U Cleats.TheShutter Frame Filled With A Upvc Multi-Chambered SinglePanel Of Size Not Less Than 620 Mm, Having Over AllThickness Of 20 Mm And 1 Mm (± 0.1 Mm) Wall Thickness.The Panels Filled Vertically And Tie Bar At Two Places ByInserting Orizontally6 Mm Galvanised M.S. Rod AndFastened With Nuts And Washers,Complete As PerManufacturers Specification And Direction Ofengineer-Incharge.(For W.C. And Bathroom Door Shutter).12 Providing And Fixing Factory Made Upvc Door FrameMade Of Upvc Extruded Sections Having An OverallDimension As Below (Tolerance±1Mm), With WallThickness 2.0 Mm (± 0.2 Mm), Corners Of The DoorframeTo Be Jointed With Galvanized Brackets And Stainless SteelScrews,Joints Mitred And Plastic Welded. The Hinge SideVertical Of The Framesreinforced By Galvanized M.S. TubeOf Size 19 X 19 Mm And 1Mm (± 0.1 Mm) Wall ThicknessAnd 3 Nos. Stainless Steel Hinges Fixed To TheFramecomplete As Per Manufacturer’S Specification AndDirection Of Engineerin-Charge Extruded Section ProfileSize 42X50 Mm13 Dismantling Wc Pan (Indian Or Europian Type) IncludingDisposal Of Rubbish Within 50 Mtr. Lead14 Providing And Fixing White Vitreous China Water ClosetSquatting Pan(Indian Type) :Long Pattern W.C. Pan OfSize 580 Mm And Providing And Fixing A Pair Of WhiteVitreous China Foot Rests Of Standard Pattern For SquattingPan Water Closet : 250X130x30 Mm15 Providing And Fixing Trap Of Self Cleansing Design WithScrewed Down Or Hinged Grating With Or Without Vent ArmComplete, Including Cost Of Cutting And Making Good TheWalls And Floors :100 Mm Inlet And 75 Mm Outlet SandCast Iron S&S As Per Is- 172916 Providing And Fixing On Wall Face Unplasticised RigidPvc Rain Water Pipes Conforming To Is : 13592 Type A,Including Jointing With Seal Ring Conforming To Is : 5382,Leaving 10 Mm Gap For Thermal Expansion, (I) SingleSocketed Pipes. 110 Mm Diameter17 Providing And Fixing On Wall Face Unplasticised - PvcMoulded Fittings/ Accessories For Unplasticised RigidPvc Rain Water Pipes Conforming To Is : 13592 Type A,Including Jointing With Seal Ring Conforming To Is : 5382,Leaving 10 Mm Gap For Thermal Expansion.Bend 87.5°110 Mm Bend18 Providing And Fixing On Wall Face Unplasticised - PvcMoulded Fittings/ Accessories For Unplasticised RigidPvc Rain Water Pipes Conforming To Is : 13592 Type A,Including Jointing With Seal Ring Conforming To Is : 5382,Leaving 10 Mm Gap For Thermal Expansion.Single Tee WithDoor 110X110x110 Mm19 Fixing Chowkhats In Existing Opening IncludingEmbedding Chowkhats In Floors Or Walls Cutting MasonryFor Holdfasts, Embedding Hold Fasts In Cement ConcreteBlocks Of Size 15 X 10 X 10 Cm With Cement Concrete1:3:6 (1 Cement : 3 Coarse Sand : 6 Graded StoneAggregate 20 Mm Nominal Size), Painting Two Coats OfApproved Wood Preservative To Sides Of Chowkhats AndMaking Good The Damages To Walls And Floors As RequiredComplete, Including Disposal Of RubbishTo The Dumping Ground Within 50 Meters Lead : DoorChowkhats20 Distempering With Oil Bound Washable Distemper OfApproved Brand And Manufacture To Give An Even Shade :Old Work (One Or More Coats)21 White Washing With Lime To Give An Even Shade :Old Work (Two Or More Coats)22 Colour Washing Two Or More Coats With Lime On OldWork.23 Painting With Synthetic Enamel Paint Of Approved BrandAnd Manufacture To Give An Even Shade : Two Or MoreCoats On New Work24 Removing Dry Or Oil Bound Distemper, Water ProofingCement Paint And The Like By Scrapping, Sand PaperingAnd Preparing The Surface Smooth Including NecessaryRepairs To Scratches Etc. Complete.25 Cleaning Of Septic Tank And Disposal Of Sludge OutsideThe Residential Area Within 2 Km Lead Including Loading &Unloading As Per The Instructions Of E-I-C.26 Brick Work With Common Burnt Clay F.P.S. (NonModular) Bricks Of Class Designation 5.0 In FoundationAnd Plinth In: Cement Mortar 1:6 (1 Cement : 6 CoarseSand)27 Providing, Hoisting And Fixing Up To Floor Five LevelPrecast Reinforced Cement Concrete Work In StringCourses, Bands, Copings, Bed Plates, Anchor Blocks, PlainWindow Sills And The Like, Including The Cost Of RequiredCentering, Shuttering But Excluding Cost Of Reinforcement,With 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded StoneAggregate 20 Mm Nominal Size).28 Steel Reinforcement For R.C.C. Work IncludingStraightening, Cutting, Bending, Placing In Position AndBinding All Complete Upto Plinth Level.Cold Twisted Bars29 Brick Work With Common Burnt Clay F.P.S. (NonModular) Bricks Of Class Designation 5.0 In SuperstructureAbove Plinth Level Up To Floor V Level In All Shapes AndSizes In :Cement Mortar 1:6 (1 Cement : 6 Coarse Sand)30 Applying One Coat Of Water Thinnable Cement Primer OfApproved Brand And Manufacture On Wall Surface :Water Thinnable Cement Primer31 Demolishing R.C.C. Work Manually/ By MechanicalMeans Including Stacking Of Steel Bars And Disposal OfUnserviceable Material Within 50 Metres Lead As PerDirection Of Engineer - In- Charge.32 Centering And Shuttering Including Strutting, ProppingEtc. And Removal Of Form For : Weather Shade, Chajjas,Corbels Etc., Including Edges33 Reinforced Cement Concrete Work In Beams, SuspendedFloors, Roofs Having Slope Up To 15° Landings, Balconies,Shelves, Chajjas, Lintels, Bands, Plain Window Sills,Staircases And Spiral Stair Cases Up To Floor Five Level,Excluding The Cost Of Centering, Shuttering, Finishing AndReinforcement, With 1:2:4 (1 Cement : 2 Coarse Sand : 4Graded Stone Aggregate 20 Mm Nominal Size).Neat Cement Of Mix : 1:4 (1 Cement: 4 Fine Sand)4 Repairs To Plaster Of Thickness 12 Mm To 20 Mm InPatches Of Area 2.5 Sq. Meters And Under, IncludingCutting The Patch In Proper Shape,Raking Out Joints AndPreparing And Plastering The Surface Of Thewalls Complete,Including Disposal Of Rubbish To The Dumping GroundWithin 50 Metres Lead : With Cement Mortar 1:4 (1Cement : 4 Fine Sand)5 Cement Concrete Flooring 1:2:4 (1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate) Finished With A Floating CoatOf Neat Cement Including Cement Slurry, But Excluding TheCost Of Nosing Of Steps Etc. Complete. 25 Mm Thick With12.5 Mm Nominal Size Stone Aggregate.6 Dismantling Old Plaster Or Skirting Raking Out Joints AndCleaning Thesurface For Plaster Including Disposal OfRubbish To The Dumpingground Within 50 Metres Lead.7 Demolishing Cement Concrete Manually/ By MechanicalMeansincluding Disposal Of Material Within 50 MetresLead As Per Directionof Engineer - In - Charge. NominalConcrete 1:3:6 Or Richer Mix (I/C EquivalentDesign Mix)8 Dismantling Doors, Windows And Clerestory Windows(Steel Or Wood)Shutter Including Chowkhats, Architrave,Holdfasts Etc. Complete Andstacking Within 50 Metres Lead: Of Area 3 Sq. Metres And Below9 Providing And Fixing 1 Mm Thick Ms Sheet Door Made OfDoor Frame 35X35x5 Mm Angle Iron And Shutter FrameMade Of 30X30x5 Mm Angle Iron Front Side 3 Nos.Horizontal Braced With 20X5 Mm Ms Flat And 1 No. BackSide With Tie On Bottom Door Frame And 2 Nos. DiagonalBraced Back Side With 20X5 Mmm Ms Flat, 6 Nos. HoldFast With 20X5 Mm Ms Flat, Hinges Made Of 3 Nos. MsSheet 3 Mm Thick With Pin 6 Mm Dia. 120 Mm WeldedShutter 2 Nos. Sliding Door Bolts (250 X 16 Mm), 2 Nos.250 Mm X 10 Mm Ms Tower Bolt And 2 Nos. Handles 125Mm Including Primer Etc. Complete Job.34 Providing Wood Work In Frames Of Doors, Windows,Clerestory Windows And Other Frames, Wrought FramedAnd Fixed In Position With Hold Fast Lugs Or With DashFasteners Of Required Dia & Length ( Hold Fast Lugs Or DashFastener Shall Be Paid For Separately). Sal Wood35 Providing And Fixing Panelled Or Panelled And GlazedShutters For Doors, Windows And Clerestory Windows,Including Isi Marked M.S. Pressed Butt Hinges BrightFinished Of Required Size With Necessary Screws,Excluding Panelling Which Will Be Paid For Separately,Complete As Per Direction Of Engineer-In-Charge.KilnSeasoned And Chemically Treated Hollock Wood 30 MmThick Shutters36 Point Wiring In Pvc Conduit, With Piano Type Switch:Wiring For Light Point/ Fan Point/ Exhaust Fan Point/ CallBell Point With 1.5 Sqmm Fr Pvc Insulated CopperConductor Single Core Cable In Surface/ Recessed PvcConduit, With Piano Type Switch, Phenolic LaminatedSheet, Suitable Size Ms Box And Earthing The Point With1.5 Sqmm Fr Pvc Insulated Copper Conductor SingleCore Cable Etc. As Required.A) Group AB) Group BC) Group C37 Supplying And Fixing Following Modular Base & CoverPlate On Existing Modular Metal Boxes Etc. As Required.Or 2 Module38 Supplying And Fixing Suitable Size Gi Box With ModularPlate And Cover In Front On Surface Or In Recess, IncludingProviding And Fixing 6 Pin 5/6 & 15/16 Amps ModularSocket Outlet And 15/16 Amps Modular Switch,Connection Etc. As Required.39 Providing And Fixing Following Capacity Tp&NDisconnector Fuse Switch Unit Inside The Existing PanelBoard With Isi Marked Hrc Fuses Including DrillingHoles In Cubicle Panel, Making Connections, Etc. AsRequired. 32 Amp Tp&N40 Supplying And Drawing Following Sizes Of Fr PvcInsulated Copper Conductor, Single Core Cable In TheExisting Surface/ Recessed Steel/ Pvc Conduit As Required.1 X 1.5 Sq. Mm