| 1 | Excavation in foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 2 | Providing and laying cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) including supply of all materials, labour T & P etc required for proper completion of the work and curing complete also including cost of formwork in foundation & floors. |
| 3 | Providing and injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete.(plinth area of the building at ground floor only shall be measured as per I.S.6313 (PartII 1981) Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or Chlordane will be used. The rate of application of chemical emulsion shall be as follows : (1) Treatment for masonary & foundation 5 liters per sqm. (2) Back fill in immediate contact with foundation 7.5 liters/sqm (3) Treatment of top surface of plinth filling 5 liters/sqm (4) Treatment junction of wall and the floor 7.5 liters /sqm (5) Treatment of soil along external perimeter of building 7.5 liters/sqm (6) Treatment of soil under apron along external perimter 5 liters/sqm. (As per manufacturer's standard dilution) |
| 4 | R.C.C. work with cement approved coarse sand and 2 cm. guage approved stone grit in the proportion of 1:1.5:3 in lintels of doors and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc.and also including supply of all materials, labour and tools and plants etc, required for proper completion of the works. including cost of binding wire. The rate excludes making of drip course which shall be paid extra.(a) Ground Floor |
| 5 | Same as above Item No. 4 but for First Floor. |
| 6 | As in item no. 4 above but for slabs (Using 1:1.5:3 Mix concrete)(a) Ground Floor |
| 7 | Same as above Item No. 05 but for First Floor. |
| 8 | As in item NO 4 but for the lighter beams i.e. having spans upto 6 m. (Using 1:1.5:3 Mix concrete) (a) Ground Floor |
| 9 | Same as above Item-6 but for First Floor. |
| 10 | As in item-4 above but in R.C.C. Raft foundation and footing with approved stone ballast.(Using 1:1.5:3 Mix concrete) |
| 11 | As in item NO. 4 above but in R.C.C. columns in 1:1.5:3 having strength not less than M-20.(a) Ground Floor |
| 12 | Same as above Item Number-8 but for First Floor. |
| 13 | M-150 brick work in 1:6 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar in foundation & plinth including supply of all materials, labour and T & P etc required for proper completion of the work. |
| 14 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 15 | Same as in item No. 9 above but in super-structure above plinth level up to floor two level ( up to two storeys ) including necessary cutting and moulding of brick work as required and also including honeycombed brick work in thickness of wall more than 12cms. (1:6 cement : coarse sand)(a) Ground Floor |
| 16 | Same as above Item No. 11 but for First Floor. |
| 17 | Same as in item no. 11 but in 1:4 cement and coarse sand mortar in superstructure for wall thickness 12 cms & below brick work.(a) Ground Floor |
| 18 | Same as above Item No. 12 but for First Floor. |
| 19 | P/F Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. (a) Ground Floor |
| 20 | Same as above Item No. 13 but for First Floor. |
| 21 | 15 mm thick plinth plaster(1 cement : 4 coarse sand ) |
| 22 | 12 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand (a) Ground Floor |
| 23 | Same as above Item No. 15 but for First Floor. |
| 24 | 12 mm cement plaster in single coat on fair side of single or half brick wall for exterior plastering up to floor two level including internal rounded angles chamfers, and/or rounded angles not exceeding 80mm in girth and finished even and smooth no extra for mixing any additive. (1)1 cement : 6 fine sand.(a) Ground Floor |
| 25 | Same as above Item No. 16 but for First Floor. |
| 26 | 12mm thick plaster in 1:3 on ceiling and soffits of stairs upto floor two level. (a) Ground Floor |
| 27 | Same as above Item No. 17 but for First Floor. |
| 28 | Cutting groove in plaster 1 cm wide & 1 cm deep by using special tools including supply of all tools and plants complete. |
| 29 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08%and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc.,.Size of Tile 600x600 mm(a) First Floor |
| 30 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. completee of Tile 600x600 mm(a) First Floor |
| 31 | 25 mm thick Kota stone slab flooring over 20 mm thick and joints filled with 1:2 cement and coarse sand with approved colouring materials to be given an even shade with 12 mm base coat (bedding ) of 1:2 cememnt and coarse sand mortar and polished by hand of machine and finally finished with french manson polish or other approved polish including supply of all materials, labour t&p etc. required for proper completion of work.(a) Ground Floor |
| 32 | Same as above Item No.21 but for First Floor. |
| 33 | Supply and fixing 10 to 12 mm thick kota stone tiles in skirting or dado laid with 1:2 cement and approved coarse sand moratrfinished with in its cement coloured slurry jointing and polishing of approved quality complete including supply of all materials, labour T&P etc required for proper completion of work.(a) Ground Floor |
| 34 | Same as above Item No. 22 but for First Floor. |
| 35 | Supply and fixing 6 mm (1/4\\") thick China glazed tiles in flooring or in skirting or dado laid with 1:3 cement and approved coarse sand mortar finished with white cement slurry jointing and polishing complete including supply of all materials, labour and tool sand plants etc. required for proper completion of the work. (Size of tiles upto 300x300mm).(a) First Floor |
| 36 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (40 mm thick floor). |
| 37 | 20 mm thick cement plaster in dado/skirting in 1:2 consistingof onepart of cement and 2 parts of aproved coarse sand laid in panels,finished with 3mm floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials labour T & P etc. required for proper completion of the work. |
| 38 | Cement concrete flooring 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 12-20mm nominal size laid in one layer neat cement (25 mm thick floor). |
| 39 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters(a) 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws single leaf |
| 40 | Same as above Item No. 27 but for Double Leaf. |
| 41 | M.S. or Iron work of small sizes and sections such as holding down bolts, hold fast tie rods, gratings etc. wrought to required from including supply of steel bolts, nuts wastage etc and fixing required for proper completion of the work.(a) Providing & fabricated of hold fast for chaukhats of doors and windows. |
| 42 | Providing & fabricated of door / windows grill. |
| 43 | Z-Section steel windows (openable) |
| 44 | Angle iron door chaukhats 40*40*5 |
| 45 | Fixing of Door, windows/ventilators chaukhats in position.For DOORS |
| 46 | WINDOWS |
| 47 | VENTILATORS |
| 48 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. (For Internal wall surface) (a) Ground Floor |
| 49 | Same as above Item No. 30 but for First Floor. |
| 50 | Finishing walls with Acrylic smooth exterior paint of required shade: - New work (Two or more coat applied @ 1.67 Ltr./10 Sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/10 Sqm. Ground Floor |
| 51 | Same as above Item No. 31 but for First Floor. |
| 52 | Distempering (Two coat) with oil bound distemper of approved brand and manufacture & of required shade on undecorated wall surface to give an even shade over & including a priming coat with cement primer of approved brand & manufacture such as Berger,J&N, Shalimar, Asian paints after thoroughly brushing the surface free from mortar droppings & other foreign matters & also including preparing the surface even with plaster of paris or approved synthetic material & sand papered smooth including cost ofall materials. for Ground Floor |
| 53 | Same as above Item No.32 but for First Floor. |
| 54 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.For Ground Floor |
| 55 | Same as above Item No. 33 but for First Floor. |
| 56 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 57 | Providing & fixing Stainless steel sliding door bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm . |
| 58 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete (a) 250 x 10mm |
| 59 | (b) 200 x 10mm |
| 60 | Providing and fixing stainless steel handles with screws etc. complete (a) 125 mm |
| 61 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. b) Laying brickbats with mortar using broken bricks/brickbats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above |
| 62 | Painting two coat over priming coat (but including cost of priming coat) on steel and other metal surfaces up to 10 cm. width or girth or small articles not exceeding 0.10sqm in area white superior synthetic enamel such as LUXOL3,Hi-gloss apcolite superlac, DULUX specified brushing to give an even shade and including cleaning the surface of all dirt,dust and other foreign matter sand papering and stoping including cost of all materials, labour tools and plants etc. required for proper completion of the work. |
| 63 | Same as item 39 above but on new wood surface. |
| 64 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 65 | Construction of drain alongwith apron. |
| 66 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors 37 mm wide and 3.15 mm thick |
| 67 | Providing & laying of light cinder filling under floor of toilets & other sunken roofs. |
| 68 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 69 | Providing and fixing MS railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary mild steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , mild steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 70 | Supply and fixing rolling sutters of approved make made of 80*125 mm (3\\"*18gauge) cold rolled MS Lath inter locked through their entire length and joined together at the end by locks and mounted on specially designed pipe shaft with brackets,side guides and arrangements for inside and outside locking with push and pull operation complete but including the cost of top cover and spring. |
| 71 | Providing and fixing ball bearing for rolling shutters |
| 72 | Sanitary Fixtures & AccessoriesProviding and fixing water closet squatting pan (Indian type W.C. pan) with 100mm sand cast iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fitting and fixtures completed including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 73 | Providing & fixing white viterous china wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting & making good the walls wherever required .Flat back Wash Basin size 450X300 mm with single 15 mm C.P. brass pillar tap. |
| 74 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.32 mm dia (for wash basin) |
| 75 | 40 mm dia (for sink and urinal) |
| 76 | Providing & Fixing 600 X 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 77 | Providing & fixing stainless steel AISI 304 (18/8) kitchen sink with out drain board as per IS :13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets cutting and making good the walls wherever required. 610 x 460 bowl depth 200 mm |
| 78 | The following items include providing, fixing and testing in position of ISI marked (IS : 1729) sand cast iron soil, waste, vent pipes and fittings cut to required lengths, fixing at wall, ceiling or on floor including connections to all required fittings complete in all respects. Providing & fixing pipes. 110mm dia SWR Pipe |
| 79 | 75mm dia SWR Pipe |
| 80 | Providing & fixing Upvc SWR Nhani trap of self cleansing design with or without ventarm complete, including cost of cutting & making good the walls & floors. a) 110mm inlet & 75mm outlet. |
| 81 | Providing and fixing plain SWR bend. 100 mm dia |
| 82 | 75 mm dia |
| 83 | Providing and fixing centrifugaly UPVC SWR single equal plain junction of required degree. a) 110x110x110mm |
| 84 | b) 75x75x75mm |
| 85 | Providing and fixing on wall face unplasticised - Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion - Single socketed pipes 110mm dia |
| 86 | Providing and fixing unplasticised - PVC pipe clips of approved design to unplasticised - Rigid PVC rain water pipes by means of 50x50x50 mm hard wood plug screwed with MS screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. for 25mm dia nominal bore |
| 88 | Same as item no 59 but for Concealed work, including cutting chases and making good the walls etc. 15mm dia nominal bore |
| 89 | Same as item no 60 but for 20mm dia nominal bore |
| 90 | Providing & fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) for 25 mm nominal bore |
| 91 | Providing and fixing ball valve (brass) of approved quality complete. (High or low pressure with plastic floats). 15 mm nominal bore |
| 92 | Providing & fixing 15 mm nominal bore 45 cm long unplasticised PVC connection pipe with brass unions. |
| 93 | Providing & fixing 15 mm nominal bore CP brass bib cock of approved quality conforming to IS 8931. |
| 94 | Providing and fixing 15 mm nominal bore C.P brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. |
| 95 | Providing & fixing 15 mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS : 8931. |
| 96 | Providing & fixing 15 mm nominal bore C.P brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931. |
| 97 | Providing & fixing 100 mm dia C.P brass shower rose with 15 mm inlet. |
| 98 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fitting and base support for tank. |
| 99 | Providing and fixing square mouth UPVC S.W.R. Gully trap grade 'A' complete with C.I. grating brick masonry chamber with F.P.S. bricks of class designation 75 and water tight C.I. cover with frame of 300 x 300mm. size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. 150 x 100 mm. size P type |
| 100 | Providing & fixing PTMT towelrail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screw 450mm. Long with total length of 495mm, width 78mm and effective height of 88mm |
| 101 | ELECTRICAL INSTALLATIONSWiring point for light with 1.5 sq.mm FRLSH PVC insulated multistrand single core Copper Conductor cable in PVC conduit pipe partly concealed in wall & partly laid in slab along with the reinforcement before concreting,complete with 1.5 sq.mm. FRLSH PVC insulated multistrand copper conductor cable earth continuity wire, piano type switches & ceiling rose / angle / batten holder on 3 mm thick phenolic paminated backelite sheet etc complete in all respects as directed, including matching color wash. |
| 102 | Same as in item no. 72 but for fan. and light duty exhaust fan |
| 103 | Same as in item no. 72 but for 5 amp plug point with piano type switch & socket etc. |
| 104 | Supply & fixing of power plug with 15 amp 250 volts flush type switch & 3 pin 15 amp 250 volts flush type socket in suitable M.S. box of 175 mm * 100mm * 50 mm size with bakelite sheet cover 3 mm thick fixed with brass machine screws & washers complete in all respect. |
| 105 | Supply & wiring of sub main with FR P.V.C. insulated 1100 volts grade single core copper conductor cable in heavy gauge P.V.C. coduit partly concealed in wall and partly laid in slab along with the reinforcement before concreting complete with FR PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit.2 x 4 sq. mm. With 1 x 2.5 sq.mm. Earth wire In 20 mm dia conduit. |
| 106 | 2 x 6 sq. mm. With 1 x 4 sq.mm. Earth wire In 25 mm dia conduit. |
| 107 | 2 x 10 sq. mm. With 1 x 6 sq.mm. Earth wire In 25 mm dia conduit. |
| 108 | S/F of surface / flush mounting SPN Distribution board without MCB complete in all respects as directed at site for 4 WAYS |
| 109 | Supply and fixing of 6 Amp to 32 Amp MCB(10KA)C Curve |
| 110 | Supply Fixing and making commection of 30 MA E.L.C.B. (Earth leakage circuit breaker) of din/R.C.C.B. rail mounting complete in all respects as per direction and satisfaction of engineer-in-charge.25 Amp 2 Pole |
| 111 | Supply & burrying of 600mm x 600mm x 6.0mm G.I. plate, vertically for earthing with its top at least 3 m below ground level complete 20mm dia. G.I.pipe and funnel for watering and one earthing lead of no. 8 SWG G.I. wire in 15 mm dia. GI pipe upto switch board (from apron to switch board the cost of GI pipe & GI wire will be extra) 300mm square C.I. box with hinged cover, masonary housing alternate layer of charcoal/coke and salt atleast 150mm thick alround etc. as per the direction of engineer in-charge complete in all respect . |
| 112 | Supplying & Laying of one number 8 to 6 SWG G. I. wire in 15 mm. dia. G. I. pipe for earthing, laid in ground or in wall duly concealed including the cost of cement, sand, labour, T & P and other material required for proper completion of the work as directed at site. |
| 113 | S/F of single light wall bracket on matching M.D.F.E.G. board base etc. complete in all respects.Category A. |
| 114 | Supply & fixing of Recess/Surface/Pendent mounting round 6 to 8 Watt LED down lighter having powder coated die cast Aluminium housing with heat sink, diffuser/reflecter, and driver set complete in all respect. Category AA |
| 115 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect.Category AAA |
| 116 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 117 | Erection and testing of exhaust fan on the existing hole with suitable size of rag bolts nuts and washers etc complete in all respects. |
| 118 | Supply & fixing hexagonal/Round G.P. Fan box of approved make made up of 1.0 mm thick ISI marked G.P. Sheet spot welded four to Eight holes of 25.4mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5mm G.P. Sheet made upper & lower cover duly screwed fitted with 300mm round zink coated M.S. Bar x 12mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material labour, T & P etc required for proper completion of the work. |
| 119 | Supply & erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-Make: Usha Cat No.SONATA MAX |
| 120 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required-Make: USHA Cat No. TURBO JET DLX 300 mm sweep Please Enable Macros to View BoQ information |