| 1 | Dismantling brick masonry in lime or cement mortar and stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 9 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 2 | Removing doors and windows with frames and stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 15 / 296Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 3 | Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts excetra complete.Item / Page No : 19 / 297Additional Specifications : The work shall be carried out as directed by Engineer-In-Charge. |
| 4 | Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting excetra complete. - (Lift upto 1.5 metre) By Manual MeansItem / Page No : 1 / 153Specification No : Bd.A.1Spec. Page No : 259 |
| 5 | Providing soling using 80 milimetre size trap metal in 15 centimetre layer including filling voids with crushed sand / grit, ramming, watering, excetra complete.Item / Page No : 40 / 157Additional Specifications : The work shall be carried out as per instructions of Engineer in-charge. |
| 6 | Providing and laying Cast in situ/Ready Mix, cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailling out water, formwork, laying/ pumping, compacting and curing, excetra complete, with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed, excetra) (using ARTIFICIAL SAND).Item / Page No : 1 / 175Specification No : Bd.E.1Spec. Page No : 287-288Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 7 | Providing and fabricting structural steel work in rolled sections like joists, channels, angles, tees, excetra as per detailed designs and drawing or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted / welded connections without connecting plates, braces, excetra and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, excetra complete. (For Ground Floor)Item / Page No : 1 / 173Specification No : Bd.C.2Spec. Page No : 275 |
| 8 | Providing and fixing of colour coated zincalume (R) AZ 150 (Minimum 150 grams per square metre total on each sides) profiled sheets for roofing. The feed material is manufactured out of nominal 0.45 milimetre base metal thickness (BMT) (0.5 milimetre TCT), Hi-strength steel with minium 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55 percent aluminium, 43.4 percent zinc, 1.6 percent silicon) with COLORBOND (R) steel quality super durable polyster paint coat (with inorganic pigment). The paint shall have a total coating thickness of nominal 35 um, comprising of nominal 25 um exterior coat on top surface and nominal 10 um reverse coat on back surface. Profile sheet shall have nominal 950-1050 milimetre effective cover width and nominal 25-30 milimetre deep ribs with subtle square fluting in the five pan at nominal 180-250 milimetre center to centre. The end rib shall be designed for anti capilary groove and return leg. The feed material should have coil manufacturer's product details marked at regular interval. Including fasteners with minium fatened with minium 25 um zinc-tin alloy coated, hex head, self-drilling screw, excetra complete. (Weight of profile 4.52 kilogram per square metre). (For Ground Floor)Item / Page No : 34 / 236Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 9 | Providing and fixing in position thermo mechnically treated FE-500 steel bar reinforcement of various dias for reinforced cement concrete pile caps, footings, foundations, slabs, beams, columns, canopies, staircases, newels, chajjas, lintels, pardis, copings, fins, arches, excetra as per detailed designs, drawings and schedules including cutting, bendding, hooking the bars, binding with wires or tack welding and supporting as requied complete. (For Ground Floor)Item / Page No : 33 / 188Specification No : Bd.F.17Spec. Page No : 306 |
| 10 | Providing second class burnt brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls / in plinth of external walls including bailling out water manually, striking joints, on unexposed faces, racking out joints on exposed faces and watering, excetra complete. (using ARTIFICIAL SAND).Item / Page No : 1 / 197Specification No : Bd.G.1Spec. Page No : 313Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 11 | Providing second class Burnt Brick masonry with conventional / Indian Standard type bricks in cement mortar 1:6 superstructure including striking joints, racking out joints, watering and scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 5 / 197Specification No : Bd.G.5Spec. Page No : 315Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 12 | Providing selected hard murum filling including laying in layers of 15 centimetre to 20 centimetre, watering and compacting, excetra compelte.Item / Page No : 24 / 82Specification No : CD.14Spec. Page No : 167 |
| 13 | Providing and fixing mild steel grill work for windows, ventilator, excetra 20 kilogram per square metre as per drawings including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 1 / 264Specification No : Bd.U.1Spec. Page No : 537 |
| 14 | Providing sand faced plaster externally in cement mortar using approved screened sand in all positions including base coat of 15 milimetre thick in cement mortar 1:4 using waterproofing compound at one killogramme per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment of 6 to 8 milimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days, scaffolding, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 11 / 209Specification No : Bd.L.7Spec. Page No : 369Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 15 | Providing and fixing black Kadappa stone as shelves 25 milimetre thick machine polished, extending the polish upto 20 centimetre width on lower side, rounding corners, laying in position, jointing with cement mortar bedding in cement mortar 1:4 proportion, curing, excetra complete. (For Ground Floor)Item / Page No : 23 / 215Specification No : Bd.M.29Spec. Page No : 391 |
| 16 | Providing and laying in position flooring of telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of approved shade and size 18 milimetre to 20 milimetre thick on a bed of 1:6 cement mortar including cement float, striking joints, pointing in cement mortar 1:3, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 34 / 216Specification No : Bd.M.3 BSpec. Page No : 380Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 17 | Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 40 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 18 | Providing and laying vitrified mirror / glossy finish tiles having size 590 milimetre to 605 milimetre X 590 milimetre to 605 milimetre of 8 milimetre to 10 milimetre thickness and confirming to Indian Standard 15622-2006 (Group BIa) of approved make, shade and pattern for dado and skirting in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 41 / 217Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 19 | Providing and laying chequered tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to indian standard for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 66 / 220Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 20 | Providing and laying antiskid ceramic tiles of approved quality of size 30 centimetre X 30 centimetre and confirming to Indian Standard 15622:2006 (Group BIIa) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 67 / 220Specification No : Bd.M.12Spec. Page No : 385Additional Specifications : If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 21 | Providing and fixing mild steel grill railing 15 kilogram per square metre with Ghana teak wood hand rail of size 75 milimetre X 60 milimetre and sill of 75 milimetre X 25 milimetre and newel posts for staircases, including fabricating, fixtures, erecting, painting the grill work with one coat of anticorrosive paint and two coats of oil painting with approved colours and polishing the sill, hand rail and newel post with french polish. (For Ground Floor)Item / Page No : 4 / 264Specification No : Bd.U.2Spec. Page No : 537 |
| 22 | Providing and fixing oval type under counter wash hand basin of 16 inch X 22 inch size and of special colour shed having telephonic black / colour granite of 18 milimetre thick fixed on black kadapaa frame work, including cromium plated coupling, bottle-trap using approved make oval type wash basin as per detailed drawing or as directed by Engineer In-charge, excetra complete. (For Ground Floor)Item / Page No : 88 / 283Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 23 | Providing and fixing 8 centimetre rigid poly vinyl chloride nahani trap including poly vinyl chloride grating, bend, connecting piece of unplasticized poly vinyl chloride pipe upto the outside face of the wall, making good damaged surface and testing, excetra complete.( Prior approval of sample and brand by Ex. Engr.is necessary before use) (For Ground Floor)Item / Page No : 17 / 288Specification No : Bd.V.32Spec. Page No : 567Additional Specifications : Prior approval of sample and brand by Executive Engineer is necessary before use. |
| 24 | Providing and fixing Anglo Indian type white glazed earthenware water closet pan with trap with unplasticized poly vinyl chloride seat and lid with chromium plated brass hinges and rubber buffers including unplasticized poly vinyl chloride vent pipe up to the outside face of wall, with flushing cistern and necessary fitting including cutting and making good to the walls and floors, testing, excetra complete. (prior approval of sample and brand by Ex. Engineer is necessary before use) (For Ground Floor)Item / Page No : 23 / 289Additional Specifications : 1. Prior approval of sample and brand by Executive Engineer is necessary before use. 2. The work shall be carried out as per instructions of Engineer in charge. |
| 25 | Providing and fixing 15 milimetre diameter poly vinyl chloride Aqua kraft type of approved make super right angle stop tap with flange including all accessories, excetra complete. (For Ground Floor)Item / Page No : 40 / 292Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 26 | Providing, laying and fixing, jointing Eco-drain 250 milimetre SN 4 Nu-Drain unplasticized poly vinyl chloride pipes or of equivalent make, manufacture as per EN 13476 or equivalent as per Indian Standard : 15328 and 16098 with fittings such a bends, tees, coupler, excetra jointing with rubber lubricant including necessary excavation, trench refilling with selective excavated material, excetra complete. (For Ground Floor)Item / Page No : 33 / 291Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 27 | Providing and fixing hume pipe septic tank 900 milimetre diameter with vent pipe and cap including excavation and laying.Item / Page No : 18 / 275Specification No : Bd.V.45Spec. Page No : 575 |
| 28 | Providing, laying and fixing polyvinyl chloride pipe of 15 milimetre diameter with fittings, such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 21 / 276Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 29 | Providing, laying and fixing polyvinyl chloride pipe of 20 milimetre diameter with fittings such as bends, tees, reducers, clamps, excetra including necessary excavation, trench filling, excetra complete.Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed excetra complete.Item / Page No : 22 / 276Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 30 | Providing and fixing 75 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps excetra complete. (For Ground Floor)Item / Page No : 51 / 279Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 31 | Providing and fixing 100 milimetre diameter stabilliser pipe / polyvinyl chloride soil vent / waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps, excetra complete. (For Ground Floor)Item / Page No : 52 / 279Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 32 | Providng and fixing in position anodised extruded aluminum partitions, partly glazed and partly laminated having frame made out of extruded tubular section of size 40 milimetre X 60 milimetre with 12 milimetre thick three layered flat pressed teak wood particle board bonded with boiling water proof type exterior grade phenol formaldehyde synthetic resin conforming to Indian Standard : 12823-1990, laminated on both sides, Novateak or equivalent and 5 milimetre thick selected quality plain / float glass panels fixed with aluminum glass clips 12 milimetre X 12 milimetre and rubber cushioning beading to glass partitions as per approved drawing, excetra compete. (For Ground Floor)Item / Page No : 72 / 260Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 33 | Providing and fixing 30 milimetre thick solid panel polyvinyl chloride internal door shutter consisting of frame made out of mild steel tubes of 19 gauge thickness and size of 40 milimetre X 20 milimetre for stiles, top, lock and bottom rails. Mild steel frame shall have a coat of steel primers of approved make and manufacture. Mild steel frame shall be covered with 5 milimetre thick heat moulded Rajshri polyvinyl chloride 'C' channel of size 30 milimetre X 100 milimetre forming stiles, and 5 milimetre thick, 125 milimetre wide poly vinyl chloride sheets for top rail, lock rail and bottom rail on either side, and 15 milimetre (5 milimetre X 3) thick, 20 milimetre wide cross poly vinyl chloride sheet as gap insert for top rail and bottom rail. Paneling of 10 milimetre thick prelam poly vinyl chloride sheet to be fitted in the mild steel frame welded / sealed to the stiles and rails with 30 milimetre wide X 5 milimetre thick poly vinyl chloride sheet beading on either side, and joined together with solvent cement adhesive, excetra An additional 5 milimetre thick poly vinyl chloride strip of 20 milimetre width is to be stuck on the interior side of the 'C' Channel using polyvinyl chloride solvent cement adhesive, including stainless steel fixtures and fastening Complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing. (For Ground Floor)Item / Page No : 81 / 261Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 34 | Providing and laying telephone black / amba white / cadbury brown / RBI red / ocean brown granite stone of 18 milimetre to 20 milimetre thick for door frame / dado / window boxing, excetra on cement mortar 1:6 including filling joints with polymer base filler, nosing the sharp edges wherever necessary, curing, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 68 / 220Additional Specifications : 1. The work shall be carried out as per the sample approved by the Engineer in-charge and kept in the office of the Executive Engineer. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 35 | Providing and fixing in position (as per Indian Standard : 1868/1982) aluminium sliding window of two tracks with rectangular pipe having overall dimentsions 63.50 milimetre X 38.10 milimetre X 1.02 milimetre at weight 0.547 kilogram per running metre and window frame bottom track section 61.85 milimetre X 31.75 milimetre X 1.20 milimetre at weight 0.695 kilogram per running metre. Top and side track section 61.85 milimetre X 31.75 milimetre X 1.30 milimetre at weight 0.659 kilogram per running metre. The shutter should be of bearing bottom 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre. Interlocking secion 40 milimetre X 18 milimetre X 1.10 milimetre at weight 0.469 kilogram per running metre and handle section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre and top section 40 milimetre X 18 milimetre X 1.25 milimetre at weight 0.417 kilogram per running metre as per detailed drawing and as directed by Engineer in-charge with all necessary aluminium sections, fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 milimetre thick plain glass with all required screws and nuts excetra complete. - With powder coating without box. (For Ground Floor)Item / Page No : 40 / 252Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 36 | Providing and fixing welded mesh of 11 gauge wires having mesh size 50 milimetre X 25 milimetre including mild steel angle frame of size 35 milimetre X 35 milimetre X 5 milimetre in position with oil painting three coats, excetra complete. (For Ground Floor)Item / Page No : 79 / 261Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 37 | Providing and fixing cold rolled steel hollow door frame 105 milimetre X 60 milimetre for any sizes including hold fast, hinges, tie members with red oxide and gray paint, excetra complete as per Indian Standards Institution specifications and code of practice prescribed including anticorosive treatment, excetra complete as directed by the Engineer. (For Ground Floor)Item / Page No : 49 / 256Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 38 | Providing and fixing mild steel grill door 24 kilogram per square metre of various size as per detailed drawings without hot dip coating, iron fixtures and fastenings and three coats of oil painting, excetra complete. (For Ground Floor)Item / Page No : 31 / 250Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 39 | Providing and fixing heavy duty inter locking concrete coloured paving blocks of 60 milimetre thickness of having a strength of 300 kilogramme per square centimetre of approved quality and shape on a bed of crushed sand of 25 milimetre to 30 milimetre thick including striking joints and cleaning, excetra complete.Item / Page No : 51 / 218Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 40 | Providing and laying Cast in situ / Ready Mix cement concrete M-15 of trap / granite / quartzite / gneiss metal for bed blocks, foundation blocks and such other items including bailling out water, plywood / steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing, excetra complete. The cement mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin, excetra (Wooden centering will not be allowed.) with fully automatic micro processor based Programmable Logic Controller without Supervisory Control and Data Aquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) excetra complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) (using ARTIFICIAL SAND).Item / Page No : 8 / 176Specification No : Bd.E.4, B-7Spec. Page No : 289-290, 38-40Additional Specifications : 1. With additional specifications for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 41 | Providing and applying Royale Luxury Emulsion of approved make on internal wall surface as detailed below - Scrapping for surface with emery paper and wipe clean for area. Applying wall primer with brush by adding mineral turpentine oil by 8 to 10 percent or water by 15 to 20 percent allowing to dry for 6 to 8 hours. After applying approved make acrylic wall putty with appropriate proportion of water of allow to dry for period of 4 to 6 hours of activity. Scrapping with emery paper and wipe clean. Applying paints Royale Luxury emulsion first coat with brush water content water 40 to 45 percent or 65 to 70 percent by role. Applying paints Royale luxury emulsion second coat with brush with water content 40 to 45 percent or 65 to 70 percent by roller. (With prior approval of S.E.) (For Ground Floor)Item / Page No : 21 / 229Additional Specifications : The work shall be done as per instructions of Engineer in charge. |
| 42 | Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacturer and of approved colour to the plastered surfaces including cleaning, preparing the plaster surfaces, applying primer coat, scaffolding, if necessary and watering the surface for two days, excetra complete. (For Ground Floor)Item / Page No : 25 / 225Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. |
| 43 | Providing and laying damp proof course 50 milimetre thick in M-20 cement concrete layer and bitumen / using cement with waterproofing compound curing, formwork, excetra complete. (For Ground Floor) (using ARTIFICIAL SAND).Item / Page No : 1 / 205Specification No : Bd.J.2Spec. Page No : 355Additional Specifications : 1. With addtional specifiactions for controlled concrete. 2. If artificial / VSI crushed sand is used instead of natural sand; terms, conditions and specifications mentioned in Circular by Chief Engineer, Public Works Region, Pune bearing No CEP/D-2/Buildings-2/5940/2017 dated 17/10/2017 and Annexure-I attached to it and also Circular by Chief Engineer, Public Works Region, Nagpur bearing No 36 dated 15/01/2019 and Annexure-I attached to it will be appicable. |
| 44 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20 metre X 0.90 metre size made out 18 gauge (1.25 milimetre) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols excetra with approved colour shade paint complete, on M.S.angle of size 35 milimetre X 35 milimetre X 3 milimetre frame with properly cross braced mild steel angles of size 35 milimetre X 35 milimetre X 3 milimetre duly painted including two mild steel angle iron posts of size 65 milimetre X 65 milimetre X 6 milimetre, 3.65 metre long painted with alternate black and white bands of 25 centimetre width including all fixtures excetraand fixing the boards in 1:4:8 concrete block of size 60 centimetre X 60 centimetre X 75 centimetre including, excavation, refilling, transportation, and labour etc complete. Spec. number As directed by Engineer in ChargeItem / Page No : 36 / 60Specification No : MoRTH-801Spec. Page No : ---Additional Specifications : The work shall be carried out as per instructions of Engineer in charge. Please Enable Macros to View BoQ information |