Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil.2.1.1 |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. for All kinds of soil.As per DSR:Vol.1:2023 item 2.8.1 |
| 3 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete,As per DSR:Vol.1:2023 item 2.25A |
| 4 | CC in 1:2:4 cement ,c/sand and 20mm stone aggregte DSR 4.1.3 |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources).As per DSR:Vol.1:2023 item 4.1.8 |
| 6 | Providing and laying in position, 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources), of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level.As per DSR:Vol.1:2023 item 5.1.2 |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : in 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) as per DSR:(Vol.-1):2023 Item 5.2.2 |
| 8 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).as per DSR:(Vol.-1):2023 Item 5.3 |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete as per DSR:(Vol.-1):2023 Item 5.9.1 |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform as per DSR:(Vol.-1):2023 Item 5.9.3 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers as per DSR:(Vol.-1):2023 Item 5.9.5 |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts as per DSR:(Vol.-1):2023 Item 5.9.6 |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges as per DSR:(Vol.-1):2023 Item 5.9.19 |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) as per DSR:(Vol.-1):2023 Item 6.1.2 |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand):as per DSR:(Vol.-1):2023 Item 6.4.1 |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand):as per DSR:(Vol.-1):2023 Item 6.4.2 |
| 17 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto and above plinth level of Thermo-Mechanically Treated bars of grade Fe-500D or more as per DSR:(Vol.-1):2023 Item 5.22.6 & 5.22A.6 |
| 18 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer Using flats 30x6mm for diagonal braces and central cross piece.as per DSR:(Vol.-1):2023 Item 10.5.2 |
| 19 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per DSR:(Vol.-1):2023 Item 10.11.1 |
| 20 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) 10.11.1 Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per DSR:(Vol.-1):2023 Item 10.11.1 |
| 21 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.10.25.2 |
| 22 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with 4.0 mm thick glass panes as per DSR:(Vol.-1):2023 Item 10.30.1 |
| 23 | 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) as per DSR:(Vol.-1):2023 Item 13.1.2 |
| 24 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) as per DSR:(Vol.-1):2023 Item 13.2.2 |
| 25 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) as per DSR:(Vol.-1):2023 Item 13.2.1 |
| 26 | 15 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) in single coat on rough side of single or half brick wall. as per DSR:(Vol.-1):2023 Item 13.5.2 |
| 27 | 12 mm cement plaster of mix 1:3 (1 cement: 3 coarse sand) with neat cement coat.13.9.1 |
| 28 | 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement as per DSR:(Vol.-1):2023 Item 13.9.2 |
| 29 | Making groove in plastered surface or moulding to R.C.C. projections.as per DSR:(Vol.-1):2023 Item 5.30 |
| 30 | Making drip course in plastered surface or moulding to R.C.C. projections.as per DSR:(Vol.-1):2023 Item 5.30 |
| 31 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes as per DSR:(Vol.-1):2023 Item 10.16.1 |
| 32 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete.as per DSR:(Vol.-1):2023 Item 10.17 |
| 33 | Providing and laying Vitrified tiles in floor in Glazed vitrified floor tiles polished finish of size 600x600mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. as per DSR:(Vol.-1):2023 Item 11.41A.2.1 |
| 34 | Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in colours White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. as per DSR:(Vol.-1):2023 Item 11.39 |
| 35 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade as per DSR:(Vol.-1):2023 Item 8.31 |
| 36 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick as per DSR:(Vol.-1):2023 11.26.1 |
| 37 | Chequered terrazo tiles 22 mm thick with graded marble chips of size up to 6 mm in floors, jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete, on 20 mm thick bed of cement mortar 1:4 (1 cement :4 coarse sand) : as per DSR:(Vol.-1):2023 11.19.4 |
| 38 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete as per DSR:(Vol.-1):2023 11.27 |
| 39 | Extra for pre finished nosing in treads of steps of Kota stone/ sand stone slab complete as per DSR:(Vol.-1):2023 11.31 |
| 40 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m² as per DSR:(Vol.-1):2023 Item 12.1.1 |
| 41 | Distempering Two or more coats on new work with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over and including water thinnable priming coat with cement primer having VOC content less than 50 gms/litre, as per manufacturer's specification. as per DSR:(Vol.-2):2023 13.41.1 |
| 42 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) in single coat on smooth side of single or half brick wall.2023 13.4.2 |
| 43 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade on New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 Lit/10 sqm):. as per DSR:(Vol.-2):2023 13.47.1 |
| 44 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per DSR:(Vol.-2):2023 Item 13.80 |
| 45 | Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture as per DSR:(Vol.-2):2023 Item 13.48.3 |
| 46 | Providing and fixing on wall face unplasticised 110mm dia Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes as per DSR:(Vol.-2):2023 12.41.2 |
| 47 | Providing and fixing on wall face unplasticised - PVC moulded 110mm Coupler fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.1.2 |
| 48 | Providing and fixing on wall face unplasticised - PVC moulded 110mm Bend 87.5° fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.5.2 |
| 49 | Providing and fixing on wall face unplasticised - PVC moulded 110mm BShoe (Plain) fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion as per DSR:(Vol.-1):2023 12.42.6.2 |
| 50 | Providing and fixing unplasticised -PVC 110mm pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete as per DSR:(Vol.-1):2023 12.43.2 |
| 51 | C.I. Pipe (100 mm dia)DSR- 17.35.1.2 |
| 52 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction complete all as per direction of Engineer-in-Charge. 80mm thick cement concrete paver block of M-30 grade with approved colour, design & pattern.16.91.2 |
| 53 | Providing and fixing terminal guard 100 mm sand cast iron S&S as per IS - 3989.DSR- 17.56.1.2 |
| 54 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design : With 20x20 mm square barDSR- 19.15.1 |
| 55 | Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg .DSR- 19.18.2 |
| 56 | Providing & Filling of O.B. brick ballast 25 mm to 40 mm size inside of upper layer in soak pit. |
| 57 | Providing and fixing water closet squatting pan ( Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS:7231, Parryware/Hindware/Seabird/Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required.White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests .17.1.1 |
| 58 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, Parryware/ Hindware/ Seabrid /Orient (Coral) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked black solid plastic seat and lid 17.2.1 |
| 59 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required. White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.17.7.2 |
| 60 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. 17.31 |
| 61 | Providing and fixing unplasticised PVC connection pipe with brass unions.45cm length & 15mm nominal bore .18.21.2 |
| 62 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean & Wall moutain type W.C. of quality and make as approved by Engineer - in - charge.17.16A |
| 63 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.17.22.A |
| 64 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms.17.71 |
| 65 | Providing & fixing soil, waste and vent pipes.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905.a) 100mm dia centrifugally cast iron S & S pipe.17.35.1.3 |
| 66 | Providing & fixing soil, waste and vent pipes.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905.a) 75mm dia centrifugally cast iron S & S pipe.17.35.2.3 |
| 67 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal .100mm 17.37.1 |
| 68 | Providing & fixing M.S. holder bat clamps of approved design to sand cast iron/centrifugally cast (Spun) iron S & S pipe embeded in & including cement concrete blocks 10x10x10cm. of 1:2:4 mix (1 cement : 2 coarse : 4 graded stone aggregate 20mm nominal .75mm 17.37.2 |
| 69 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.100mm .17.38.1.3 |
| 70 | Providing and fixing bend of required degree with access door, insertion rubber washer 3mm thick, bolts and nuts complete.75mm .17.38.2.3 |
| 71 | Providing and fixing plain bend of required degree.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905.100mm.17.39.1.3 |
| 72 | Providing and fixing plain bend of required degree.Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905.75mm.17.39.2.3 |
| 73 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100mm dia.100x100x100mm 17.43.1.2 |
| 74 | Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100mm dia.75mmx75mmx75 17.43.2.2 |
| 75 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 100x100x100.17.44.1.3 |
| 76 | Providing and fixing centrifugaly cast iron single equal plain junction of required degree. 75mmx75mmx75.17.44.2.3 |
| 77 | Providing and fixing single unequal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete :100mmx100mmx75mm.17.47.1.2 |
| 78 | Providing and fixing single unequal plain invert branch of required degree : :100mmx100mmx75mm.17.52.1.3 |
| 79 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)100mm 17.55.1.2 |
| 80 | Providing and fixing door piece, insertion rubber washer 3mm thick, bolts & nuts complete :( c.o.p.)75mm 17.55.2.2 |
| 81 | Providing and fixing cast iron terminal guard. 100mm.17.56.1.2 |
| 82 | Providing and fixing cast iron terminal guard. 75mmmm.17.56.2.2 |
| 83 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe.100mm. SS 304 grade coupling with EPDM rubber gasket.17.57A.1.1 |
| 84 | Providing and fixing shielded coupling for Hubless centrifugally cast iron pipe.75mm. SS 304 grade coupling with EPDM rubber gasket.17.57A.2.1 |
| 85 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :a) 100mm inlet & 100mm outlet.17.60.1.3 |
| 86 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms.17.73.1 |
| 87 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work-Exposed on wall.32mm niminal bore.18.7.4 |
| 88 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.20mm dia nominal outer dia pipes.18.8.2 |
| 89 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc.25mm dia nominal outer dia pipes.18.8.3 |
| 90 | Providing and fixing GI pipes complete with GI fittings and clamps, including cutting and making good walls etc. ( for wash basin waste ).32mm dia nominal bore18.10.4. |
| 91 | Providing and fixing C.P. brass shower rose with 15 or 20mm inlet.150mm dia.18.22.2 |
| 92 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.18.48 |
| 93 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 .15mm nominal bore.18.49.1 |
| 94 | Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS:8931.15mm bore.18.53.1 |
| 95 | Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931:15mm dia.18.52.1 |
| 96 | Providing and fixing cp soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms..18.65 |
| 97 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group A.1.10.1 |
| 98 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC Conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.1.12 |
| 99 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.1 |
| 100 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.2 |
| 101 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.4 |
| 102 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.1.14.10 |
| 103 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.1.19 |
| 104 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.25mm.1.20.2 |
| 105 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV socket outlet.1.24.7 |
| 106 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.1.25 |
| 107 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1.27.1 |
| 108 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.1.31 |
| 109 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.1.32 |
| 110 | Supplying and fixing brass batten/ angle holder including connection etc. as required.1.34 |
| 111 | Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.1.35 |
| 112 | Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep.1.50 |
| 113 | Extra for fixing the louvers/ shutters complete with frame for aexhaust fan of all sizes.1.51 |
| 114 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulatedcopper conductor single core cable etc. as required.group A.151.1 |
| 115 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 1.56 |
| 116 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. 1.57 |
| 117 | Supplying and fixing PVC batten/ angle holder including connections etc. as required.1.58 |
| 118 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)12 way , Double door.2.3.3 |
| 119 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).6 way (4 + 18), Double door.2.4.2 |
| 120 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole.2.10.1 |
| 121 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole.2.10.3 |
| 122 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple Pole & Neutral.2.10.5 |
| 123 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.100 mm width X 50 mm depth X 1.6 mm thickness.4.1.1 |
| 124 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.. 5.4. |
| 125 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.5.11 |
| 126 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.. 5.15 |
| 127 | Supply and fixing of recess/surface/pendent mounting round 6 watt to 8 watt LED down lighter having powder coeted die cost alluminium housing with heat sink, defuser/Reflector and driver set complete in all respect CAT-AAA.SOR NO.1401 |
| 128 | Supply and fixing of 3 watt to 6 watt LED (spot light) fiting conferming to IP 66 and above protection complete in all respect CAT-AAA (Use as a decorative mirror light). Sor No.1441A |
| 129 | Supply and fixing of LED Tuve light with metal heavy duty Box type batten light fitting 2X22 watt suitable for upto 2X22 watt LED Polycarbonaate tube light complete Including tube suitable for both surface & suspended complete in all respect CAT-AAA.SOR NO.1414 |
| 130 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.DSR NO.19.1 |
| 131 | Supply and fixing hexagonal Round G.P.fan box approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work.DSR Civil 2023 10.18 |
| 132 | Provision of inauguration or Opening project including diging foundation layig c,c, in 1:6:12 as per S.I.No 273, brick work in 1:4 with S.I. No 305a, plaster in 1:4 with S.I. No 584. and snowcem S.I. No 660 including fixing 60x75 cm sixe 20 mm thick gran |
| 133 | Provision of inauguration or Opening project including diging foundation layig c,c, in 1:6:12 as per S.I.No 273, brick work in 1:4 with S.I. No 305a, plaster in 1:4 with S.I. No 584. and snowcem S.I. No 660 including fixing 60x75 cm sixe 20 mm thick gran |
| 134 | Boring 150mm dia bore hole i/c Labour T&P as required proper completion of the workJal Nigam VNS |
| 135 | Supplying assembling lowering and fixing in vertical position in bore well, unplastisized PVC medium well casing(CM) pipe of 100mm PVC dia, confirming to IS 12818 i/c required hire and labour charges , fitting accessaries etc.all complete as per Direction of Engineer In Charge .DSR 23.3.1 |
| 136 | Surroung and packing Gravel between bore well and the strainer i/c supply of gravel and Labour T&P etc required for proper completion of the work. Nigam VNS |
| 137 | Providing and fixing of 32mm dia GI pipe nomonal bore complete with GI fittings.DSR 18.12.3 |
| 138 | Submercible pump Kirlosker/ Crowmpton or Equivqlent 2HP ISI Mark.Manpuri UPPWD SOR |
| 139 | Singal Phase starter for submercible pump of ISI Mark.Manpuri UPPWD SOR |
| 140 | 2.5 sqmm Cable for Submercible motor pump.Manpuri UPPWD SOR |
| 141 | 4\\" dia MS Clamp made with 32 Sqmm flat iron with Nutt & Bolt.DSR 23.14.1 |
| 142 | 100mm dia & PVC end CapUPPWD SOR |
| 143 | Solution for jointing PVC pipe 250gram.Manpuri UPPWD SOR |
| 144 | Providing and fixing chlorinated polyvinyl chloride pipehaving thermal stability for hot and cold water supply i/c all CPVC plan and cross threaded fittings . This includes jointing of pipe and fitting with one step CPVC solvent cement, trenching, refilling and testing of joint complete as per direction of Engineer incharge, External work 32mm nominal dia pipe.DSR 18.9.4 |
| 145 | Development of tube well in accordance with IS 2800 (Part-1) and IS 1189 to established maximum rate of usuable water yield without sand.including disinfaction of tube well all complete i/c hire and Labour charges of air compressor tools & accessaries etc as required for proper completion of work..DSR 23.12 |
| 146 | Nylon cloth for strainer i/c plastic rope , cutting holes in PVC pipe etc complete.Manpuri UPPWD SOR |
| 147 | Providing India Mark-II hand pump wiith all accessaries.Jal Nigam VNS |
| 148 | Fixing of India Mark-II Handpump with connecting rod.Jal Nigam VNS |
| 149 | Construction of HP Chabutara in all Complete.Jal Nigam VNS Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail