| 1 | Surface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m All kinds of soil. |
| 3 | Extra for every additional lift of 1.5 m or part thereof in. All kinds of soil. |
| 4 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 5 | FILLING IN PLINTH WITH BEST AVAILABLE LOCAL SAND UNDER FLOORS INCLUDING WATERING, RAMMING CONSOLIDATING AND DRESSING COMPLETE |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 7 | Carriage of material by mechanical transport including loading, unloading and stacking: Lime, moorum, building rubbish: Lead 1 KM. |
| 8 | Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centering, shuttering, finish & reinforce - All work up to plinth level:1:1.5:3(1 cem:1.5 coarse sand:3 graded stone agg. 20 mm nominal size) |
| 9 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 Cement: 2 Coarse:4 graded stone aggregate 12.5 mm nominal size). |
| 10 | Applying a coat of residual petroleum bitumen of grade VG 10 of approved quality using 1.7 Kg per SQM on Damp Proof Course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 11 | Reinforced cement concrete work in beams , suspended floors, roofs having slope up to 15 degrees, landings, balconies, shelves, chhajjas, lintels, bends, plain window sills, stair cases and spiral stair cases up to floor five level excluding the cost of centering, shuttering and finishing and reinforcement :-With 1:1.5:3 ( 1 Cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 12 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement: 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) |
| 13 | Centering and shuttering including strutting, propping etc. and removal of form for:-Foundations, footings, bases of columns, etc. for mass concrete. |
| 14 | CENTERING AND SHUTTERING INCLUDING STRUTTING, PROPPING ETC. AND REMOVAL OF FORM WORK FOR: COLUMNS, PILLARS, PIERS, ABUTMENTS, POSTS AND STRUTS |
| 15 | Centering and shuttering including strutting, propping etc. and removal of form for: -Suspended floors, roofs, landings, balconies and access platform. |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for :-Lintels, beams, plinth beams, girders, bressummers and cantilevers. |
| 17 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete: -Cold twisted bars |
| 18 | ADD OR DEDUCT FOR PLASTER DRIP COURSE/GROOVE IN PLASTERED SURFACE OR MOULDING TO RCC PROJECTIONS |
| 19 | Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in: Cement mortar 1:6 (1 cement: 6 coarse sand) |
| 20 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 21 | Half brick masonry with F.P.S. bricks of class designation 75 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 22 | BRICK EDGING 7CM WIDE 11.4CM. DEEP TO PLINTH PROTECTION WITH BRICKS OF CLASS DESIGNATION 75 INCLUDING GROUTING WITH CEMENT MORTAR 1:4 (1 CEMENT : 4 FINE SAND) |
| 23 | Providing and fixing aluminum sliding door bolts, ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required color or shade, with nuts and screws etc. complete : 300x16 mm |
| 24 | Providing and fixing aluminum sliding door bolts, ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required color or shade, with nuts and screws etc. complete :250x16 mm |
| 25 | Providing and fixing aluminum tower bolts, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required color or shade, with necessary screws etc. complete :150x10 mm |
| 26 | Providing and fixing aluminum tower bolts, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required color or shade, with necessary screws etc. complete :100x10 mm |
| 27 | Providing and fixing aluminum handles, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required color or shade, with necessary screws etc. complete :125 mm |
| 28 | Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required color and shade, with necessary screws etc. complete. Single rubber stopper |
| 29 | Grading roof for water proofing treatment with: Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size |
| 30 | Providing and fixing chromium plated brass 50 mm cupboard or wardrobe knobs with nuts complete. |
| 31 | Providing and fixing aluminum work for doors, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved mark confirming to IS: 733 and IS: 1285, fixed with dash fasteners of required dia. and size, including necessary fillings up of gaps at junctions at top, bottom and sides with required EPDM Rubber / Neoprene gasket etc. Aluminum sections shall be smooth rust free straight metered and jointed mechanically wherever required including clit angle aluminum snap beading for glazing / paneling C.P Brass/ stainless steel screws all complete as per architectural drawing and the directions of Engineering in Charge (Glazing, paneling dash fasteners to be paid for separately). For shutters of doors, windows and ventilators including providing and fixing hinge/pivots and making provision for fixing of fittings wherever required including the cost of EPDM Rubber / Neoprene gasket required (fitting shall be paid for separately) Power coated aluminum (Minimum thickness of powder coating 50 micron). |
| 32 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/ sqm) |
| 33 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia. M.S. bar bent to shape with hooked ends in R.C.C. slabs, beams during laying including painting the exposed portion of loop, all as per standard design complete. |
| 34 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption's less than 0.08% and conforming to IS : 15622 of approved make in all colors and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 60x60 cm |
| 35 | PROVIDING AND LAYING CERAMIC GLAZED FLOOR TILES 300X300 MM (THICKNESS TO BE SPECIFIED BY THE MANUFACTURER) OF 1ST QUALITY CONFORMING TO IS : 15622 ,PIGMENT ETC., COMPLETE |
| 36 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colors, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 37 | Providing and fixing GI pipes complete with GI fittings and clamps including making good the walls etc. concealed pipe including painting with anti-corrosive bitumastic paint , cutting chases and making good the wall15 MM nominal bore |
| 38 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls etc. Internal work exposed on wall : 20 MM nominal bore : |
| 39 | Providing and fixing GI pipes complete with GI fittings and clamps including cutting and making good the walls etc. Internal work exposed on wall : 25 MM nominal bore |
| 40 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc. external work :-25 MM nominal bore |
| 41 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc. external work :-40 MM nominal bore |
| 42 | Providing and fixing GI pipes complete with GI fittings including trenching and refilling etc. external work :- 50 MM nominal bore |
| 43 | PROVIDING AND FIXING BRIGHT FINISHED BRASS 100 MM. MORTICE LATCH AND LOCK WITH 6 LEVERS AND A PAIR OF LEVER HANDLES WITH NECESSARY SCREWS ETC. COMPLETE.(BEST MAKE OF APPROVED QUALITY) |
| 44 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design :100x100 mm size P type with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 45 | Providing and fixing PTMT grating of approved quality and color. Circular type :125 mm nominal dia. with 25 mm waste hole each |
| 46 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste and vent pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes.(A)110 mm diameter |
| 47 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste and vent pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,(i) Single socketed pipes. (B) 75 mm diameter |
| 48 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.(A)Single tee with door75x75x75 mm |
| 49 | (B)Single tee with door110x110x110 mm |
| 50 | Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion Coupler - 75 mm |
| 51 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED - PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAIN WATER PIPES CONFORMING TO IS : 13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS :5382 LEAVING 10 MM GAP FOR THERMAL EXPANSION. COUPLER - 110 MM |
| 52 | (E) Single push fit Coupler 75 mm |
| 53 | (F) Single push fit Coupler 110 mm |
| 54 | (G) Single tee without door75x75x75 mm |
| 55 | (F)Single tee without door110x110x110 mm |
| 56 | Providing and fixing on wall face unplasticised - PVC moulded fittings/Accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion. Bend 87.5°- 75 mm bend |
| 57 | PROVIDING AND FIXING ON WALL FACE UNPLASTICISED - PVC MOULDED FITTINGS/ACCESSORIES FOR UNPLASTICISED RIGID PVC RAIN WATER PIPES CONFORMING TO IS : 13592 TYPE A INCLUDING JOINTING WITH SEAL RING CONFORMING TO IS :5382 |
| 58 | (I) Shoe (Plain)75 mm Shoe |
| 59 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes IS : 5382, including jointing with seal ring leaving 10 mm gap for thermal expansion. Shoe (Plain)- 110 mm |
| 60 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. (A) 75 mm |
| 61 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement: 4 coarse sand) and making good the wall etc. complete. 110 MM |
| 62 | Constructing brick masonry manholes with locally best available bricks in cement mortar 1:4 ( 1 cement : 4 sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 120x90 cm and 90 cm deep including providing & fixing RCC cover as per required size. |
| 63 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter |
| 64 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed concrete as per standard design : 200 mm diameter S.W. pipe |
| 65 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and over flow arrangement and making necessary holes for inlet, outlet and over flow arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. per liter |
| 66 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore |
| 67 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :50 mm nominal bore |
| 68 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge,( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 69 | 15 mm cement plaster on the rough side of single or half brick wall of mix :1:4 (1 cement: 4 fine sand) |
| 70 | 6 mm cement plaster of mix :1:3 (1 cement: 3 fine sand) |
| 71 | WALL PAINTING WITH ACRYLIC EMULSION PAINT OF APPROVED BRAND |
| 72 | Finishing walls with water proofing cement paint of required shade :New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 73 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 74 | Diluting and injecting chemical emulsion for POST-CONSTRUCTIONA Lanti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion@ one liter per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 75 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer - in- charge. |
| 76 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 77 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete |
| 78 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: |
| 79 | Extra for providing and mixing water proofing material in cement concrete work @ 1 kg per 50kg of cement. |
| 80 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : 20 mm dia. (heavy type) |
| 81 | DISMANTLING DOORS WINDOWS AND CLERSTORY WINDOWS (STEEL OR WOOD) SHUTTER INCLUDING CHOWKHATS, ARCHITRAVE, HOLDFASTS ETC. COMPLETE AND DEPOSITING THE SAME IN CENTRAL/SITE STORES. OF AREA 3 SQ.M AND BELOW |
| 82 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. In cement mortar |
| 83 | PROVIDING AND FIXING BRIGHT FINISHING HYDRAULIC DOOR CLOSER ( BEST MAKE OF APPROVED QUALITY ) WITH NECESSARY ACCESSORIES AND SCREWS ETC. COMPLETE. |
| 84 | P&F of superior quality PVC fitting for sewerage pipe line I/c jointing with rubber lubricant & solvent cement and testing :PVC collar 75 mm dia. |
| 85 | P&F of superior quality PVC fitting for sewerage pipe line I/c jointing with rubber lubricant & solvent cement and testing :PVC collar 110 mm dia. |
| 86 | P&F of superior quality PVC fitting for sewerage pipe line I/c jointing with rubber lubricant & solvent cement and testing :PVC cowl 110 mm dia. |
| 87 | PROVIDING AND APPLYING WHITE CEMENT BASED PUTTY OF AVERAGE THICKNESS 1 M.M. OF APPROVED BRAND AND MANUFACTURER OVER THE PLASTERED WALL SURFACE TO PREPARE THE SURFACE EVEN AND SMOOTH COMPLETE. |
| 88 | Providing and fixing 12 mm thick prelaminated particle board pressed 3 layer or graded wood particle board confirming to IS : 12823 grade I Type II, in paneling fixed in aluminum doors , windows shutters and partition frames |
| 89 | Providing and fixing of \\"JAQUAR\\" Central Hole Basin Mixer(material code no. QQT-7167B) |
| 90 | Providing and fixing of \\"JAQUAR\\" Pillar Cock(material code no. QQT-7011) |
| 91 | Providing and fixing of \\"JAQUAR\\" Wall Mixer With Provision For Overhead Shower(material code no. QQT-7234UPR) |
| 92 | Providing and fixing of \\"JAQUAR\\" Bib Cock(material code no. QQT-7037) |
| 93 | Providing and fixing of \\"JAQUAR\\" Angle Stop Cock(material code no. QQT-7053) |
| 94 | Providing and fixing of \\"JAQUAR\\" Overhead Shower 120mm Round Shape(material code no. OHS-1663) |
| 95 | Providing and fixing of \\"JAQUAR\\" Single Towel Rail 600mm(material code no. ACN-1111SM) |
| 96 | Providing and fixing of \\"JAQUAR\\" Soap Dish Holder(material code no. ACN-1131N) |
| 97 | Providing and fixing of \\"JAQUAR\\" Glass Shelf 600mm-CP with 5mm glass sheet(material code no. ACN-1171N) |
| 98 | Providing and fixing of Bathroom Mirror- size 2.5'x3' with ply |
| 99 | Providing and fixing of Wardrobe Mirror- size- 4'x1.25' with ply |
| 100 | 15 MM BRASS BALL VALVE COMP. 15MM/5/8INCH (minimum 230 gm) |
| 101 | Providing and fixing of \\"JAQUAR\\" HAND OPERATED C.P. WATER JET.(Length 1.5 meter)(material code no. ALD-587) |
| 102 | Providing and fixing of S.S. flexible CONNECTION PIPE 1/2 INCHES DIAMETER. (LENGTH 450 M.M) |
| 103 | Providing and fixing of PVC WASTE PIPE WITH COUPLING 32 MM |
| 104 | Providing and fixing of \\"HINDWARE\\" One Piece Closet with white plastic seat COMPLETE(Cat. No. 20122) |
| 105 | Providing and fixing of \\"HINDWARE\\" Wash Basin (Cat. No. 10045) |
| 106 | Providing and fixing of \\"JAQUAR\\" Paper holder OF S.S.(material code no. ACN-1153S) |
| 107 | Providing and fixing of \\"JAQUAR\\" Towel Ring Round S.S.(material code no. ACN-1101S) |
| 108 | Providing and fixing of \\"JAQUAR\\" Soap Dispenser (material code no. ACN-1135N) |
| 109 | Providing and fixing of \\"JAQUAR\\" Corner Glass Self(material code no. ACN-1173) |
| 110 | Providing and fixing 18 mm thick gang saw cut, mirror polished, pre moulded and pre polished, machine cut granite for kitchen platforms, laid over 20 mm thick base cement mortar 1:4 finish |
| 111 | Providing and fixing white vitreous china water closet squatting pan (Indian type)Orissa pattern W.C. pan of size 580x440 mm |
| 112 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White |
| 113 | Providing and fixing C. I. P- Trap 100 mm diameter for W.C. |
| 114 | Providing and fixing G.I. inlet connection for flush pipe connecting with W.C. pan. |
| 115 | Providing & fixing of 32 Amp MCB in modular box for air conditioner & Geyser supply with plug & socket of 32 A |
| 116 | Supply & installation of 12 points complete modular plastic board with sheet as per the requirement of cutting of switches |
| 117 | Supply & installation of 2 points power modular plastic board with sheet as per the requirement of cutting of switches |
| 118 | Supply & installation of 4 points modular plastic board with sheet as per the requirement of cutting of switches |
| 119 | Supply & connection of piano type 5/6 A modular plastic switch in modular plastic board |
| 120 | Supply & connection of piano type 5/6 A modular plastic Socket in modular plastic board |
| 121 | Supply & connection of piano type 15/16 A modular plastic Socket in modular plastic board |
| 122 | Supply & connection of piano type 15/16 A modular plastic switch in modular plastic board |
| 123 | Supply & connection of piano type 5/6 A Electronics modular plastic fan regulator in modular plastic board |
| 124 | Supply & connection of piano type 5/6 A modular plastic bell switch in modular plastic board |
| 125 | Supply and laying of 6 sq. mm FR copper wire |
| 126 | Supply and laying of 2.5 sq. mm FR copper wire |
| 127 | Supply and laying of 1.5 sq. mm FR copper wire |
| 128 | Supply and laying of 1 sq. mm FR copper wire |
| 129 | Supply & installation PVC pipe power line of 40 mm ISI mark |
| 130 | supply & installation 25 mm PVC pipe of ISI mark |
| 131 | Supply & installation 15 mm PVC pipe of ISI mark |
| 132 | Supply, installation & connection of ceiling rose |
| 133 | supply, installation & connection of angle holder |
| 134 | SUPPLY & INSTALLATION OF DECORATIVE WALL FITTING GALLERY LIGHTS OF SUITABLE WATTAGE |
| 135 | SUPPLY & INSTALLATION OF EXHAUST FAN |
| 136 | Supply, installation & connection of Lighting Distribution board as per the specification |
| 137 | Supply & Installation of LED Tube light (Batten) complete 20/22-Watt,4 feet length, Operating voltage-100V to 300V, Conformity to standard IS |
| 138 | Supply & Installation of 25-litre, 2 kW, 5-star BEE-rated storage geyser |
| 139 | Supply and installation of 1.5-ton 5-star rated Inverter split AC with high energy efficiency (ISEER ratings) |
| 140 | Supply and installation of 5-star rated ceiling fan BLDC (Brushless DC) motor 1200mm sweep with remote control as per IS standard. Please Enable Macros to View BoQ information |