| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbing down with water etc complete all as specified and directed. |
| 3 | M&L for cement plastering 10mm thick in cement mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 4 | M&L for cement plastering 5mm thick in cement mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 5 | M&L for cement plastering 15mm thick in cement mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair without using extra cement as and where directed complete all as specified and as directed. |
| 6 | Supply only integral liquid water proofing compound complete all as specified and directed. |
| 7 | Complete removal of existing treatment of any type/description from ceilings/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. |
| 8 | Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. |
| 9 | M&L for applying two coats of oil bound distemper white or tinted over a coat of primer on walls over & incl preparation of New surface of wall all specified and directed. |
| 10 | M&L for applying two coats of oil bound distemper white or tinted over a coat of primer on walls brick or RCC surfaces over & incl preparation of old surface of wall complete all specified and directed. |
| 11 | M&L for applying one coats of oil bound distemper white or tinted over a coat of primer on walls brick or RCC surfaces over & incl preparation of old surface of wall complete all specified and directed. |
| 12 | M&L for applying 2mm thick wall care putty in walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc (for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving exterior/internal painting complete all as specified and directed. |
| 13 | Material and Labour for exterior painting work including complete removal of existing loose paint layers till plaster level by using jet pressure washer and crack filling up to 3mm by using crack seal & up to 10mm by using textured crack filler. Application of one coat of SmartCare waterproof primer (Damp Prime Suprema) on walls and Chajjas with 10% of dilution of water, incl 3mm thick wall care putty and applying two coats of 100% acrylic smooth emulsion exterior grade with silicon additives having anti-algal and Dust pickup resistance properties, Material should be applied (Dilution, Recoating period etc..) as per manufacturer instructions by using fully automatic air less spray machine having flow speed of minimum 1ltr per minute and pressure of 3300 PSI. |
| 14 | M&L for applying 02 coats of exterior emulsion weather proof paint (light shade) @ 5 sq.m/litre/2 coats by using roller to external walls/RCC surfaces/soffits of chajjas/ roof projections/ cantilevers/ balcony etc surfaces over & including a coat of exterior wall primer @ 10 sq.m/1.43litre/1 coat as recommended for under coat by manufacturer of exterior emulsion by using following brands of emulsion and primer complete all as specified and directed.Note for item No. 12 to 14 : The contractor shall furnish the gurantee for 04 (four) years for smart periodical on his letter head. If any defects noticed during this period the same shall rectified by the contractor without any extra cost to the Govt. |
| 15 | M&L for preparation of new plastered surfaces of ceiling and applying three coat of white wash on ceiling surfaces complete all as specified and directed. |
| 16 | M&L for preparation of old plastered surfaces of ceiling and applying three coat of white wash on ceiling surfaces complete all as specified and directed. |
| 17 | M&L for preparation of old plastered surfaces of ceiling and applying one coat of white wash on ceiling surfaces complete all as specified and directed. |
| 18 | Supply and applying rust remover cum passivator by brush in two coat @ 0.3 kg/m2/coat of Density: 1.01 Kg/l at 300C complete all as per manufacturer's instructions complete all as specified and directed. Note : The application of rust removal shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. |
| 19 | Supply and applying cementitious coating for corrosion protection having a cement based polymer modified rebar corrosion protection system by applying the first coat approx. 1mm thick layer of product carbonation resistance 2 mm of SikaTop Armatec®-108 or equivalent as approved by the GE corresponds to 20 mm of normal mortar; bond strength > 1N/mm2 according to ASTM C 882-78 applying @ 4 kg/m2 for two coats on to the prepared reinforcing steel with a medium- stiff brush. It is unavoidable that specified product will also be applied on to the surrounding concrete. The second coat is applied in the same way after a waiting time of 2-3 hours (at +20°C) complete all as per manufacturer's instructions and all as specified.Note : The application of Cementitious Coating for Corrosion Protection shall be got done through the authorised applicator of manufacturer of membrane only as approved by the GE |
| 20 | Providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including preparation of surface by chipping and throughly cleaning of surface complete wherever required and as approved by the GE.Consumption: 0.5 kg/m2. as per manufacturer's instructions and complete all as specified and directed.Product requirements: Complies with ASTM C 881 Type II Grade 2 Class B+C.Note : The application of Epoxy Bonding Primer shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. |
| 21 | Supply and applying a pre-batched one component polymer modified cementitious patch repair mortar in 25 mm thickness.Yield: approx. 0.84 ltr/kg. heaving following yield as requirement.System requirements: compressive strength >= 50 N/mm2 (28 days) according to ASTM C 109; flexural strength >= 3N/ mm2 (7 days) according to ASTM C 293-79.Consumption of 2.1 Kg/Sqm/mmNote : The application of Polymer repair Mortar shall be got done through the authorised applicator of manufacturer of membrane only all as approved by the GE. |
| 22 | Taking down cement plaster from brick work or RCC surface and proper cleaning the surface with water and making efflorescence treatment by applying two layer of fastflex Dr. fixit (Pidilite co.) over brick surface and including finally apply 15 mm thick plastering cement mortar in 1.3 with mixing of (URP 301) over treated surfaces and Applying 3mm thick wall care putty applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 23 | Taking down cement plaster from brick work or RCC surface and proper cleaning the surface with water and making efflorescence treatment by applying two layer of fastflex Dr. fixit (Pidilite co.) over brick surface and including finally apply 10 mm thick plastering cement mortar in 1.6 with mixing of (URP 301) over treated surfaces and Applying 3mm thick wall care putty applying Two or more coats of oil bound distemper white or tinted over a coat of primer on walls incl one coat of primer over & incl preparation of New surface of wall complete all as specified and directed. |
| 24 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good to existing surfaces by brick work, plastering, finishing to match with the existing surface including making reqd shape for hold fast block for the new frame complete all as specified and directed. |
| 25 | Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good to existing surfaces by brick work, plastering, finishing to match with the existing surface including making reqd shape for hold fast block for the new frame complete all as specified and directed. |
| 26 | Taking down shutters exc 1 sqm and n exc 2sqm and refixing in same opening after necessary adjustment complete all as specified and directed. |
| 27 | S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing , supply & fixing in opening as per specification & drawing complete all as specified and directed. |
| 28 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door Frame/Chowkhat of size 125 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 29 | S&F Factory made double extruded/rebated WPC (Wood Polymer Composite) solid door Frame/Chowkhat of size 150 x 65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete all as specified and directed.Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 30 | S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 5mm thick Moulded PVC Sheet on the front face & 5 mm plain colour PVC sheet on back face consisting of frame made out of M.S. tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, including supplying & fixing complete all as specified and directed. |
| 31 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed. |
| 32 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid decorative type plain wire mesh door shutter of size 35mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk)and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. Incl fixing of stainless steel 304 Grade wire cloth (wire dia. 0.56mm) and Expanded stainless steel, wire dia 1.20 mm thickness and mesh aperture size 38x20mm (LWxSW) combinly panel area of door except stiles and rail to be panelled with mesh with self tapping round headed screws at required distance, scres and edges covered with feathered PVC edge beading all round of mesh and WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and directed.Note(for item No 28, 29, 31 & 32):- The contractor shall produce the manufacturer test certificate in the specification mentioned in the items . In the absence of the same no measurement shall be done by the executives. |
| 33 | S&F 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plate including fixing like welding etc complete all as specified and directed. |
| 34 | Demolition of reinforced cement concrete for roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work and the like. Including cutting of steel bars , if required at site conditions complete all as specified and directed. |
| 35 | S&F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet of having TCT 0.45mm thick, rib height 28mm, Min G300 Mpa grade, pitch 200mm with 16mm step depth of colour as approved as in roof covering/cladding to wall with self tapping screws fixed with fasteners/screws as recommended by manufacturer complete all as specified. Note :- fixing of sheet will be done strictly according as per manufacturers instructions. PPGI moulded at 90 degree round with min 30cm depth.Note (for item No 34 &35):-Rates should be incl scaffolding work upto 10m height. |
| 36 | Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed. Please Enable Macros to View BoQ information |
| 37 | Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed. Please Enable Macros to View BoQ information |