| 1 | Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead 14.1.1 With cement mortar 1:4 (1 cement : 4 fine sand) |
| 2 | Providing and applying Plaster of Paris putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete |
| 3 | Finishing walls with water proofing cement paint of required shade on new work (two or morFinishing walls with water proofing cement paint of required shade: Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @ 0.80 liters/10sqm complete including cost of priming coat.e coats applied @3.84kg / 10 sqm) |
| 4 | Renewing glass panes, with wooden fillets wherever necessary : Float Glass panes thickness 4.0mm (weight not less than 10kg/sqm) |
| 5 | Supplying and fixing new wooden fillets wherever necessary : 2nd Class Teak Wood Fillets |
| 6 | Painting on G.S sheets with synthetic enamel paint of approved band and manufacture of required colour to give an even shade on New work (two or more coats) incl. A coat of approved steel primer but excl. A coat of mordant solution |
| 7 | Removing dry or oil bound distemper. Water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 8 | Applying priming coat: With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood) |
| 9 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coat on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 10 | Regrading terracing of mud phaska covered with tiles or bricks, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 meters lead. |
| 11 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto alead of 5 km also including ramming and watering of the earth in layers not exceeding 20 cm intrenches, plinth, sides of foundation etc. complete. |
| 12 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. |
| 13 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge |
| 14 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 15 | SteelreinforcementforR.C.C.workincludingstraightening,cutting,bending,placinginpositionandbindingallcompleteuptoplinthlevel |
| 16 | Providing & Fitting concealed Internal Electrification of room including 4 No LED Lights, Fan Point - 2 No Fuse Box 1 No 15 Amp Sockets with switch5 amp, 2 No sockets with switch of approved brand and 4 No LED Security Light 30 Watts Main Switch with complete wiring, with M S Bracket for pole mounting complete incl. service line upto length of 15 Mtr (As pper the direction of Engineer-Incharge) |
| 17 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid. |
| 18 | ProvidingandfixingwashbasinwithC.I.brackets,15mmC.P.brass pillartaps, 32mm C.P.brass waste of standard pattern, including Painting of fitting sand brackets, cutting and making good the walls of15mmC.P. brass pillar taps. |
| 19 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively |
| 20 | Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 21 | Cutting road and making good the same in cluding supply of extra quantities of material i.e. crushed aggregate, moorum screening, red bajri and labourr equired. |
| 22 | Dismantlingmanually/mechanicallyincludingstackingofserviceablematerial and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: Water bound macadam road. |
| 23 | Demolishing cement concrete manually/by mechanical means including disposal of material within 50 meters lead as per direction of Engineer-incharge: 1:3:6 or richer mix (i/c equivalent design mix) |
| 24 | Taking out existing CC interlocking paver blocks from footpath/ centralverge,including removal of rubbish etc., disposal of unservice able material tothe dumping ground, for which pay ment shall be made separatelyandstacking of serviceable material within 50 meter lead as per direction of Engineer-in-Charge. |
| 25 | Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. Not exceeding 1.5 mtr in width and for shafts, wells, cesspits and the like in all kinds of soil |
| 26 | Excavating, supplying and filling of local earth (including royalty)by mechanical transport upto a lead of 5 km also including ramming and watering of the earth in Layer not exceeding 20 cm in trenches, plinth side of foundation etc complete |
| 27 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of Centering & Shuttering (All work upto Plinth Level with 1:4:8 (1 Cement : 4 Sand : 8 Graded stone agg) upto 40 mm |
| 28 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of Centering & Shuttering (All work upto Plinth Level with 1:3:6 (1 Cement : 3 Sand : 6 Graded stone agg) upto 20 mm |
| 29 | Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiralstair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 Cement : 1½ Sand : 3 Stone agg upto 20 mm |
| 30 | Centering & Shuttering including strutting removal work for foundation, footing, base etc. |
| 31 | Walls any thickness incl. Attached pilasters, buttresses, plinth & string course etc Plinth 1st Step Above Ground Level |
| 32 | Centring and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platforms. |
| 33 | Brick work with common burnt clay F.P.S. (non-modualar) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement :6 coarse sand) (New Wall) |
| 34 | Brick work with common burnt clay F.P.S. (non-modualar) bricks of class designation 7.5 in foundation and plinth in Cement mortar 1:6 (1 cement :6 coarse sand) (Labour Rate) |
| 35 | Extra for Brick Work with common burnt clay bricks / cement concrete bicks in super-sturcture above plinth level upto floor five level |
| 36 | Half brick masonry with common brunt clay ( non- modular) bricks of class designation 7.5 in foundation and plinth including curing in cement mortar 1:4 (1 cement : 4 coarse sand) (New Wall) |
| 37 | Half brick masonry with common brunt clay ( non- modular) bricks of class designation 7.5 in foundation and plinth including curing in cement mortar 1:4 (1 cement : 4 coarse sand) (Labour Rate) |
| 38 | Extra for Half Brick work masonry in superstructure above plinth level upto floor V level |
| 39 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m. (stacks of cleaned bricks shall be measured) : |
| 40 | 15mm thick Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 coarse sand) . |
| 41 | Finishing walls with water proofing cement paint of required shade on new work (two or more coats appled @ 3.84kg/10sqm) |
| 42 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 gradedstoneaggregate) finished with a floating coat of neat cement including cementslurry and curing complete, but excluding the cost of nosing of steps etc.complete 40 mm thick with 20 mm nominal size stone agg. |
| 43 | Layingoldcementconcreteinterlockingpaverblocksofanydesign/shape laid in required line, level, curvature, colour and pattern over andincluding 50 mm thick compactedbedof coarse sand, filling the jointswith finesandetc.allcompleteasper thedirectionofEngineer-in-charge. |
| 44 | Providing, Laying & Fitting of G I Pipes Pipe with complete fitting excluding earth work & refilling etc 150 mm Dia |
| 45 | Providing, Laying & Fitting of G I Pipes Pipe with complete fitting excluding earth work & refilling etc 100 mm Dia |
| 46 | Providing, Laying & Fitting of G I Pipes Pipe with complete fitting excluding earth work & refilling etc 80 mm Dia |
| 47 | Providing, Laying & Fitting of G I Pipes Pipe with complete fitting excluding earth work & refilling etc 65 mm Dia |
| 48 | Providing, Laying & Fitting of G I Pipes Pipe with complete fitting excluding earth work & refilling etc 50 mm Dia |
| 49 | Providing, Laying & Fitting of G I Pipes Pipe with complete fitting excluding earth work & refilling etc 40 mm Dia |
| 50 | Providing, Laying & Fitting of G I Pipes Pipe with complete fitting excluding earth work & refilling etc 15 mm Dia |
| 51 | Filling available excavated earth (excluding rock) intrenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, lead upto 50m and lift upto1.5m. |
| 52 | Making inter connections with distribution mains incl. Cost & fixing of Valves & Pipes Specials complete 50 mm to 80 mm nominal Bore |
| 53 | Making inter connections with distribution mains incl. Cost & fixing of Valves & Pipes Specials complete 25 mm to 40 mm nominal Bore |
| 54 | Providing & Fixing of C.I.Sluice Valve (With Cap) complete with bolts, nuts, rubber insertion etc. (the tail piece if required will be paid seprately ) 100 mm dia class - I |
| 55 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 80 mm Nominal Bore |
| 56 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) 65 mm Nominal Bore |
| 57 | Providing & Fixing 15 mm (Nominal Size) Brass Bib Cock of approved Brand 15 mm Nominal Bore |
| 58 | Providing & Fixing 15 mm (Nominal Size) Brass Ferrule of approved Brand 15 mm Nominal Bore |
| 59 | Cost for welding works in distribution system for manifold at Tubewell Station fabrication of bends etc. of required degree. |
| 60 | Carriage of Sand and stone agg. Below 40 mm from nearest source of supply to the site of work av. distance 20 Kms by MT |
| 61 | Carriage of Stone aggregate (above 40 mm) from nearest source of supply to the site of work av. distance 20 Kms by MT |
| 62 | Carriage of earth filling from nearest source of supply to the site of work av. distance 5 Kms by MT |
| 63 | Carriage of Brick & Tiles from nearest source of supply to the site of work av. distance 05 Kms by MT Please Enable Macros to View BoQ information |