| 1 | CONSTRUCTION OF PROPOSED GUARD ROOM |
| 2 | Clearing grass and removal of rubbish up to a distance of 30 m outside the periphery of the area as per technical specification clause 201 |
| 3 | Providing Layout & centerline for building i/c all labour T&P complete |
| 4 | Excavation in foundation in ordinary soil (loamclay or sand) including lift up to 1.5m and lead up to 30m. and including filling watering and ramming of excavated earth into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth ad directed by the Engineer in charge up to a distance of 30m. from the foundation trenches including all T&P phowarah and basket etc. complete. |
| 5 | Cement concrete with 4 cm gauge approved stone ballast, approved coarse sand and cement in the proportion 8:4:1 including supply of all materials, labour and T & P etc. required for proper completion of the work. |
| 6 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete |
| 7 | Sand filling in plinth including supply of necessary quantity of sand from a distance not exceeding 8 km.(5 miles) from the site of work and including watering, dressing etc. Rate to include cost of alt materials, labour and T&P etc. required for proper completion of the work. (Analysis Rate) |
| 8 | M-150 Brick work in 1:6 cement and coarse sand mortar in foundation and plinth including supply of all material, labour and tools and plants ect. Require for proper completion of work. (303+3 |
| 9 | M-150 Brick work in 1:6 cement and coarse sand mortar in super structure all material, labour and tools and plants ect. Require for proper completion of work. |
| 10 | for Parapet and 4.5\\" wall 1:4 cement abd coarse sand |
| 11 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Plinth bend |
| 12 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Lintel bend |
| 13 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Sunshade |
| 14 | R.C.C work with cement approved coarse sand and 2 cm. gauge approved stone ballast in the proportion of 1:1.5:3 in lintels of doors and windows excluding its fixing and binding the same with 24 B.W.G.G.I binding wire and including necessary centering and shuttering etc. and also including supply of all materials required for proper completion of the work. Binding wire to be supplied by the contractor free of cost. Slab |
| 15 | Providing & fixing 1 mm thick MS sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junctions & corners, all necessary fitting complete, including supplying & priming coat of approved steel primer, using flats 30x6 mm for diagonal beaces and central cross piece |
| 16 | Providing & fixing of MS Z-section window with MS sheet shutter & grill of 10mm sqbar size 1.20x1.20 mtr & for ventilation of size 0.60x0.45 |
| 17 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in an over all rates) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastege. bend hooks and authorized.(504) for beam |
| 18 | 2cm (3/4\\") thick cement plaster in dedo or skirting in 1:2 consisting of one part of cement and 2 parts of approved coarse sand laid in panels, finished with 3 mm (1/8\\") floating coat of neat cement or cement and marble dust in ratio of 5:1 including supply of all materials, labour and T&P etc. required for proper completion of the work. (597) |
| 19 | 12mm. thick plaster with cement mortar consisting of 1 part cement and 6 part of approved coarse sand. minimum thickness not to be less than 10mm including supply of all material, labour and T&P etc. required for proper completion of the work. (583) |
| 20 | 12/15mm thick inside wall plaster 1:6 cement : coarse sand mortar (584 + 596) |
| 21 | 40mm thick without base CC floor 1:2:4 cement,coarse sand&20mm stone grit |
| 22 | Providing and applyong white cement based putty of average thickness 1mm of approved brand and manufacture over the plastered wall surface to prepare the surface even and smooth complete (13.80) |
| 23 | Finishing walls with acrylic smooth exterior paint of required shade (13.111) |
| 24 | Distempering with 1st quality acrylic distemper (read made) having VOC content less than 50 gm per ltr of approved manufacture and of required shade and colour complete as per manufacture's specification. (13.108) |
| 25 | Painting with synthetic enamal paint of approved brand and manufacture of required colour to give an shade (13.92) i/c one coat primer |
| 26 | Providing & fixing of rain water spout pipe 60 cm long supreme/prince |
| 27 | Providing and Laying vitrified floor tiles oi approvemake and Brand n dfference size (thicknessspecfled by rnanufacturer) with waier absorptonless than 0.8% and confrming to lS 15622 of approved make in a colors and shade lad on20mm thck cement mortar 1:4 (lcement 4 coarsesand) includ ng orout ng the jo nts with white cement and maiching pigments etc complete sizeof t es 300x300mm. |
| 28 | GUARD ROOM ELECTRICAL |
| 29 | Wiring for light point/fan point /exhaust fan point /call bell/Sodium point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. Group C |
| 30 | Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 31 | Wiring for Circuit/Submain wiring along with earth wire with the Following size FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire |
| 32 | Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. Single pole |
| 33 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. 40 Amp. |
| 34 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface / recess, complete with tinned copper bes bar, neutral bus bar, earth bar, din bar,interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way , Double door |
| 35 | Installation, testing and commissioning of ceiling fan, including wiring of the down rods of standard length (upto 30 cm) with 1.50 sq. mm, FRLS PVC insulated, copper conductor, single core cable including providing and fixing phenolic laminated sheet cover on the fan box etc.. as required. |
| 36 | Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 37 | Supplying and fixing brass batten/ angle holder including connectionetc. as required |
| 38 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required. |
| 39 | Supply and fixing of hexagonal / round G P fan box of approved make made up 1.0 mm thick ISI Marked G.P. sheet spot welded four to Eight holes of 25.40 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.50 mm G P sheet made upper and lower cover duly screwed fitted with 300 mm round zink coted M S bar x 12 mm and brand name should be embossed, fixing with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material, labour, T&P etc. required for proper completion of work. |
| 40 | Supply and fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect. Cat AA |
| 41 | Supply & Fixing of LED Street Light fitting having die cast aluminium body and diffuser with driver set suitable for 45 watt to 50 watt. Confirming to IP 66 protection complete in all respect. Cat-AA |
| 42 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 2000 mm, Outer pipe 50 mm, inner pipe 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I. strip will be extra) Complete in all respect with G.I. wire 8 SWG. |
| 43 | S/F of Kit-Kat fuse 32 Amp with neutrail link ,wooden ply board ,Hole fasner with connection |
| 44 | Supply & Fixing of Fan Sheet of Backelite |
| 45 | S/F of LED Bulb 9 watt ISI |
| 46 | S/f of ceiling fan 1200 mm sweep. Single star rated Usha / Crompton/Bajaj mak |
| 47 | S/L of Service Cable 10 sq.mm x 2 core with G.I. support wire. |
| 48 | Construction Of Additional Class Room (G.F. & F.F.) |
| 49 | Earth Work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m. as directed by Engineer in charge. (0.30 m and above) |
| 50 | Anti termite treatment in foundations |
| 51 | Sand Filling In Plinth |
| 52 | PCC work in foundation with 1:4:8 (1 cement : 4 coarese sand : 8 graded stone aggregate 40 mm nominal size |
| 53 | RCC work in foundation, footings, bases for columns including the cost of centering, shuttering, propping etc with 1:1:5:3 (1 cement : 1.5 coarse sand : graded stone aggregate 20 mm nominal size) |
| 54 | Steel used in above RCC work @ 2% |
| 55 | Brik work with common burnt clay (non modular) bricks of class- 150 in foundation and plinth in all shapes and sizes with cement mortal with 1:6 (1 cement : 6 coarse sand) |
| 56 | RCC Work in plinth beam excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:5:3 (1 cement : 1.5 coarse sand : graded stone aggregate 20 nominal size |
| 57 | Steel used in above RCC work @ 1.5% |
| 58 | Brick work with common burnt clay (non modular) bricks of class - 150 in super structure above plinth level upto floor V level in all shapes and size with cement cement mortar with 1:6(1 cement : 6 coarse sand) |
| 59 | RCC work in columns & beams excluding the cost of centering, shuttering finishing and reinforcement with 1:1.5:3(1 cement : 1.5 coarse sand : graded stone aggregate 20 mm nominal size) |
| 60 | Steel used in above RCC work @ 1.5% |
| 61 | RCC work in jambs of doors and windows excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand : graded stone aggregate 20 mm nominal size) |
| 62 | Steel used in above RCC work |
| 63 | RCC work in slab, sunshades, chhajja etc. excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand: graded stone aggergate 20 mm nominal size |
| 64 | Steel used in above RCC work @ 1.0% |
| 65 | Earth Filling |
| 66 | Sand Filling in flooring |
| 67 | PCC work in foundation with 1:4:8 (1 cement : 4 coarese sand : 8 graded stone aggregate 40 mm nominal size |
| 68 | Providing and Laying vitrified floor tiles oi approvemake and Brand n dfference size (thicknessspecfled by rnanufacturer) with waier absorptonless than 0.8% and confrming to lS 15622 ofapproved make in a colors and shade lad on20mm thck cement mortar 1:4 (lcement 4 coarsesand) includ ng orout ng the jo nts with whitecement and maiching pigments etc complete sizeof t es 300x300mm. |
| 69 | 12 mm cement plaster of mix 1:4 (1 cement :4 coarse sand) |
| 70 | Providing and applying white cement based putty of average thickness 1mm |
| 71 | Providing & fixing 1 mm thick MS sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junctions & corners, all necessary fitting complete, including supplying & priming coat of approved steel primer, using flats 30x6 mm for diagonal beaces and central cross piece |
| 72 | Roof terrecing with mortar 1:3 (1 cement : 3 coarse sand |
| 73 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two or more coats) over and including priming coat with cement primer. |
| 74 | Finishing walls with 2 Coat Premium Acrylic Smooth exterior paint with Silicone additives of required shade |
| 75 | Painting on Iron work with one coat of ready mixed priming Paint & one coat of approved superior quality ready mixed paint including all materials |
| 76 | MS Handrail for Ramp |
| 77 | MS Railing for Chajja & Stair Case |
| 78 | Foundations, footings, bases of columns, etc. for mass concrete |
| 79 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 80 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 81 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick |
| 82 | Supply And Fixing Of Green Board |
| 83 | Providing & fixing of rain water spout pipe 60 cm long supreme/prince |
| 84 | Letter Writing On Wall (Class Name Coutation etc.) |
| 85 | WIRING POINTS - |
| 86 | Wiring for light point / fan point / exhaust fan point / call bell point with 1.50 Sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable G I box and earthing the point with 1.50 sq. mm FRLS PVC insulated copper conductor single core etc. as required. Group C |
| 87 | Supplying and fixing metal box of following sizes (normal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 200 mm x 250 mm x 60 mm deep |
| 88 | SUBMAINS - |
| 89 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit as required. 2 x 2.50 sq. mm + 1 X 2.50 sq. mm earth wire |
| 90 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but modular plate etc. as required. |
| 91 | Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required. |
| 92 | Supplying and fixing suitable size G I box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 93 | MINIATURE CIRCUIT BREAKER |
| 94 | Supplying and fixing 5 A to 32 A rating, 250 / 415 V, 10 Ka, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. required. |
| 95 | Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. required. |
| 96 | Supply and fixing of Following way , single way and neutral , sheet steel , MCB Distribution board , 240v , on surafce / recess, complete with tinned copper bus bar , neutral bus bar , earth bus bar , din bar , interconnection , powder painted including earthing etc. as required 4 way Double door |
| 97 | Supplying and fixing of following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. modular base and cover plate for modular switches in recess etc. as required. 5 / 6 A Switch |
| 98 | Supplying and fixing of following modular switch / socket on the existing modular plate and switch box including connections but excluding modular plate etc. as required. modular base and cover plate for modular switches in recess etc. as required. 3 pin 5 / 6 A socket outlet |
| 99 | Supply and fixing of LED Tube Light with Metal heavy duty Box type batten light fitting 1 x 22 Watt suitable for upto 1 X 22 W LED Polycarbonate tube light complete including tube etc. on surface complete in all respects. CAT: AAA, 2420 system lumens, 110 lm/W, PF>0.95,THD<10% at full load, CRI>80, Tube with aluminium heat with 5 year warranty. |
| 100 | Erection and testing of celling fan and regulator etc. excluding supply of down rad, complete in all respect. |
| 101 | Supply and fixing of hexagonal / round G P fan box of approved make made up 1.0 mm thick ISI Marked G.P. sheet spot welded four to Eight holes of 25.40 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.50 mm G P sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S. bar x 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting along with supply of all material, labour, T&P etc. required for proper completion of work. |
| 102 | Supply of Ceiling fan 1200 mm sweep, Double ball bearing , Capacitor type ISI marked / Five star complete etc. Usha / Crompton / Bajaj / Khaitan make. |
| 103 | Supply and fixing of fan box sheet on existing fan box complete in all respects. |
| 104 | Supply and fixing of LED Bulb 12 - 15 Watt, Bajaj / Crompton / Havells / Philips make. |
| 105 | cable for service connection 10sq mm x 2 core Please Enable Macros to View BoQ information |