| 1 | Taking down old unserviceable point wiring of any description including all fittings and fixtures like switches, sockets, ceiling rose, fan regulator, tubelight,, mirror light,, ceiling light etc complete all as specified and directed. |
| 2 | M&L for Point wiring with 1.5 Sqmm FRLS-H insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS-H insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories / junction boxes / inspection covers etc of suitable size but not less than 20mm(OD), concealed in wall/ floor etc including provision of earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass GI screws/ modular cover plate as required for mounting switches, sockets, fan regulator, etc. / modular metal flush box covered with modular frame plate with cover of any size as per site requirement for mounting modular switches, modular sockets, modular fan regulator etc complete all as specified and directed for one light / ceiling fan / exhaust fan / call bell point controlled by one switch |
| 3 | All as per item No 2 here-in-before but one 6A socket point controlled by one switch on independent board |
| 4 | All as per item No 2 here-in-before but one 6A socket point controlled by one switch on same board |
| 5 | All as per item No 2 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 6 | All as per item No 2 here-in-before but one wiring in existing conduit for one light / ceiling fan / exhaust fan / call bell point controlled by one switch. |
| 7 | All as per item No 2 here-in-before but one one 6A socket point controlled by one switch on independent board |
| 8 | All as per item No 2 here-in-before but one one 6A socket point controlled by one switch on same board |
| 9 | All as per item No 2 here-in-before but one one light point controlled by two No. two way switch complete all as specified and directed |
| 10 | All as per item No. 2 here-in-before but one 16A socket point controlled by one 16A switch on independent board with 2.5 sqmm wires. |
| 11 | M&L for sub main wiring along with earth wire with FRLS-H insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 25mm concealed in wall/ floor etc including taking down existing unserviceable sub main wiring of any description complete all as specified and directed for 2runs x 4 sqmm(Ph & N) + 1run x 4 sqmm(earth wire):- (Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length) |
| 12 | All as per item No 11 here-in-before but 2runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) |
| 13 | All as per item No 11 here-in-before but 2runs x 10 sqmm(Ph & N) + 1run x 10 sqmm(earth wire) |
| 14 | All as per item No 11 here-in-before but 4runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) Please Enable Macros to View BoQ information |
| 15 | All as per item No 11 here-in-before but 4runs x 6 sqmm(Ph & N) + 1run x 6 sqmm(earth wire) Please Enable Macros to View BoQ information |