Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Clearing jungle including uprooting of rank vegatations grass, bush, wood trees and saplings of girth upto 30cm. Measured at a height of 1 metre above ground level & removal of rubbish upto a distance of 50 metres outside the periphery of area cleared. |
| 2 | Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 3 | Excavation of Foundation-Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.RAIN WATER HARVESTING+SEPTIC TANK |
| 4 | Same as Bove but for RAIN WATER Same as Bove but for HARVESTING+SEPTIC TANK |
| 5 | Same as Bove but for RAIN WATER HARVESTING |
| 6 | Excavating. Supplying, stacking and filling of local earth (including roylaty) by mechhanical transport upto a lead of 5 km. also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complate for all lift. |
| 7 | Sand Filling-Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 8 | PCCProviding and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 9 | Providing & injecting chemical emulsion for pre constructional antitermite treatment and creating a chemical barrier under and around the column pits wall trenches basement excavation top surface if plinth junction of wall and floor, along the external perimeter of binding expansion joints, surrounding of pipes and conduit etc., complete (plinth area of the building at ground floor only shall be measured as per IS-6313 Part II 1981)Aldrine emulisifiable concentrate or any other approved material such as Hepthachlor or Chlordance will be used. The rate of application of chemical emulsion shall be as follows- (I) Treatment for masonary & foundation 5 Ltr. per Sqm. (II) Back fill in immediate contact with foundation 7.5 Ltr.per Sqm. (III) Treatment of top surface of plinth filling 5 Ltr.per Sqm. (IV) Treatment of soil along external peri meter of building 7.50 Ltr. per Sqm. (V) Treatment of soil under apron along external perimeter 5 Ltr. per Sqm. S.I.No. 1 Chapter 8 |
| 10 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 11 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 12 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 13 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 15 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 17 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. |
| 18 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, erraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 19 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202(Part I) On one side only |
| 20 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202(Part I) On one side only Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 21 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof.The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. |
| 22 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete (Hold fast) |
| 23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. |
| 24 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment) Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)..(Z-Section Window) |
| 25 | Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 26 | Providing and fixing fly proof Stainless steel grade 304 wire gauge to windows and lerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.50 mm all complete.With 2nd class teak wood beading 62X19 mm. |
| 27 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete . Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) (Below GL.) |
| 30 | 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) |
| 31 | 15 mm cement plaster on rough side of single or half brick wall of mix : 1:6 (1 cement: 6 coarse sand) |
| 32 | Forming groove of uniform size from 12x12 mm and upto 25x15 mm in the top layer of washed stone grit plastered surface as per approved pattern, including providing and fixing aluminum channels of appropriate size and thickness (not less than 2 mm), nailed to the under layer with rust proof screws and nails and finishing the groove complete as per specifications and direction of the Engineer-in-Charge. |
| 33 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 34 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 35 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 36 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 37 | SERVICE BLOCK BUILDING Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement.18 mm thick |
| 38 | SERVICE BLOCK BUILDING Providing and fixing glass strips in joints of terrazo/ cement concrete floors.(40 mm wide and 4 mm thick) CIVIL WORK |
| 39 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 40 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm |
| 41 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick |
| 42 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 43 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete |
| 44 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm |
| 45 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture |
| 46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/10 sqm of approved brand and manufacture |
| 47 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 48 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 49 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 50 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 51 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 52 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378) (300x16mm) |
| 53 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete (Copper oxidised as per IS 1378) (250x10mm) (a) 250 mm x 10mm |
| 54 | Providing and fixing ISI marked oxidised M.S. handles conforming to 1S:4992 with necessary screws etc. complete (Copper oxidised as per IS 1378) 125mm) |
| 55 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 56 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Ordinary cement without any pigment. |
| 57 | Providing and laying six courses water proofing treatment with bitumen felt over roofs consisting of first, third and fifth course of blown bitumen 85/25 or 90/15 conforming to IS : 702 applied hot @ .45, 1.20 and 1.45 Kg per square metre of area respectively, second and fourth courses of roofing felt type 3 grade I conforming to IS : 1322 (Hessian based self finished bitumen felt) , sixth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per sqm including preparation of surface but excluding grading, complete. |
| 58 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishingand making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 59 | Providing and fixing on wall face unplasticised- PVC moulded fittings/ accessories forunplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 110 mm Bend 87.5° |
| 60 | Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power. The styles and rails shall be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push fit type) will be set inside the styles and the rails with a cavity, to receive single piece extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with the help of PVC solvent cement & self driven self tapping screws. Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness 5 mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm complete as per manufacturer's specifications and direction of Engineer-in-charge. Decorative finish (both side wood grained finish) |
| 61 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.80x1.25 mm M.S. laths with 1.25 mm thick top cover. |
| 62 | Providing and fixing ball bearing for rolling shutters. |
| 63 | Centering and shuttering including strutting, propping etc. and removal of form for all heights :UPTO PLINTH LVL. Centering and shuttering including strutting, propping etc. and removal of form: in Foundations, footings, bases of columns, etc. for mass concrete |
| 64 | ABOVE PLINTH LVL. Centering and shuttering including strutting, propping etc. and removal of form: in Suspended floors, roofs, landings, balconies and access platform |
| 65 | Centering and shuttering including strutting, propping etc. and removal of form: in Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 66 | Centering and shuttering including strutting, propping etc. and removal of form: in Columns, Pillars, Piers, Abutments, Posts and Struts |
| 67 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. M.D. -10- Circular shape 500mm internal diameter |
| 68 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-incharge, upto 90 metre depth below ground level. Drilling of 300mm dia bore hole manually. |
| 69 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 70 | Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 71 | Supplying, filling, spreading & leveling gravels of size range 5 mm to 10mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 72 | Supplying, filling, spreading & leveling coarase sand of size range 1.5 mm to 2mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer-in-charge. |
| 73 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction of Engineer-in-charge. |
| 74 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works (Gate steel work) |
| 75 | Providing and fixing G.I. pipes complete with G.I. fittings including trenchingand refilling etc G.I. Pipe (80 MM DIA) (DSR-18.12.8) |
| 76 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all lead & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 DSR 16.78.2 |
| 77 | Construction of dry lean cement concrete sub base over a prepared sub-grade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge. DSR 16.80 |
| 78 | P/L of 125 micron polythene sheets as per Material rate M-104 |
| 79 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber,finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately). Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately Cement concrete prepared with batch mixing machine DSR 16.43.1 |
| 80 | P/L in Position Bitumin hot sealing compound for expansion joints DSR 16.46.1 C.C. ROAD |
| 81 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all lead & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-Ill (size range 26.5 mm to 0.075 mm ) having CBR Value-20 DSR 16.78.3 |
| 82 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 83 | INTERNAL WATER SUPPLY SANITATION Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 84 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISI marked white plastic seat and lid |
| 85 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. |
| 86 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS : 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510x1040x200mm |
| 87 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe b) 40mm dia |
| 88 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete. Semi rigid pipe b) 32mm dia |
| 89 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 90 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required a) Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 91 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required b) Range of two half stall urinals with 5 litre P.V.C. automatic flushing cistern |
| 92 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS :2556, C.I. trap with outlet grating and other couplings in C.P. brass including painting of fittings and brackets, cutting and making good the walls and floors wherever required c) Range of three half stall urinals with 10 litre P.V.C. automatic flushing cistern |
| 93 | Providing and fixing stone slab table rubbed, edges rounded and polished of size 75x50cm deep and 1.8cm thick fixed in Urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1cement: 2coarse sand: 4graded stone aggregate 6mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade |
| 94 | Providing and fixing 8 mm dia C.P./S.S. Jet with flexible tube upto 1 meter long with S.S. triangular plate for Eureopean type W.C. of quality and make as approved by engineer-in-charge. 15mm nominal bore |
| 95 | Providing and fixing CP Brass 32 mm size Bottal Trap of approved quality & make and as per thedirection of Enginer-in-charge. |
| 96 | Providing and fixing CP Brass Single lever lelephonic wall mixture of quality & make and as per thedirection of Enginer-in-charge. a) 15mm dia nominal dia. |
| 97 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet a) 100 mm diameter |
| 98 | Providing & fixing 600x120x5 mm glass self with edges round off, supported on anodiesd aluminium angle framewith C.P. brass bracket and guard rail complete fixed with 40 mmlong screws, rawl plugs etc, complete. |
| 99 | Providing and fixing PTMT Liquid soap container 109 mm wide ,125 mm high and 112 mm distance from wall of standerd shape with bracket of the same material with snap fittings of approved quality and colour weighing not less than 105 gms. |
| 100 | Providing & fixing PTMT towl rail complete with brackets fixed to wooden cleats with cp brass screws with concealed fitting arrangement of approved quality and colour. 600 mm. long towl rail length of 645 mm. width 78 mm. and effective height of 88 mm, weighing not less than 190 gms. |
| 101 | Providing & fixing 32 # G.I. Pipes spout including cutting & making good the walls etc. |
| 102 | Providing & fixing 25 # G.I. Pipes spout including cutting & making good the walls etc. |
| 103 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. |
| 104 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 mm O.D. |
| 105 | Same as Above but 110 mm O.D. |
| 106 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet |
| 107 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 108 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110mm |
| 109 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 110 | Providing & fixing G.I. pipes complete with G.I. fittings & clamps including cutting & making good the walls etc. (internal work) Exposed on wall 50mm dia nominal bore |
| 111 | Painting G.I. pipes and fittings with two coats of anti corrosive bitumastic paint of approved quality. 50mm dia nominal bore. |
| 112 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. internal work -Exposed on wall 20mm dia nominal outer dia pipes |
| 113 | 25mm dia nominal outer dia pipes |
| 114 | 50mm dia nominal outer dia pipes |
| 115 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge. |
| 116 | 20mm dia nominal outer dia pipes |
| 117 | 25mm dia nominal outer dia pipes |
| 118 | Providing & fixing CP brass bib cock of approved quality conforming to IS 8931 15mm nominal bore |
| 119 | Providing & fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15mm nominal bore |
| 120 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore |
| 121 | Providing and fixing gun metal gate valve with wheel of approved quality. 25mm dia nominal bore |
| 122 | 20 mm dia nominal bore |
| 123 | 50mm dia nominal bore |
| 124 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore |
| 125 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. exceeding 80mm dia. But not exceeding 300 mm dia. |
| 126 | Providing, laying and joining glazed stone ware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete. 100mm diameter |
| 127 | 150mm diameter |
| 128 | 200mm diameter |
| 129 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design. 100mm diameter S.W. Pipe |
| 130 | 150mm diameter S.W. Pipe |
| 131 | 200mm diameter S.W. Pipe |
| 132 | Providing and fixing square mouth S.W. Gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300x300 mm size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design: 150 x 100 mm. size P type With Sewer bricks conforming to IS : 4885 |
| 133 | Constructing brick masonry manhole in cement mortar 1:4 (1 cement :4 coarse sand) RCC top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement :4 coarse sand :8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with floating coat fo neat cement and making channels in cement concrete 1:2:4 (1 cement :2 coarse sand :4 graded stone aggregate 20mm nminal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90x80cms and 45cms deep including CI cover with frame (light duty) 455x610mm internal diamensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15kg). With FPS bricks of class designation 75 (i) For Sewer Line |
| 134 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Extra for depth for manholes: Size 90x80cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 135 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 136 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank. IS:12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 137 | Providing and laying Non pressure NP2 class (light duty) RCC pipe with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1cement : 2 fine sand ) including testing of joints etc. complete. 150mm diameter |
| 138 | SERVICE BLOCK BUILDING Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) upto the haunches of S.W./R.C.C. pipes including bed concrete as per standard design 150 mm. dia. RCC Pipe |
| 139 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. 15mm nominal bore |
| 140 | POINT WIRING Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular type switch, modular plate, suitable size G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 141 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular type switch, modular plate, suitable G.I. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 142 | Wiring for circuit/sub-main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2X1.5 sqmm + 1x1.5 sqmm earth wire |
| 143 | 2X2.5 sqmm + 1x 2.5 sqmm earth wire |
| 144 | 2X4.0 sqmm + 1x 4.0 sqmm earth wire |
| 145 | 2X6.0 sqmm + 1x 6.0 sqmm earth wire |
| 146 | 2X10.0 sqmm + 1x 6.0 sqmm earth wire |
| 147 | 4X6 sqmm + 2x 6.0 sqmm earth wire |
| 148 | 4X10 sqmm + 2x 6.0 sqmm earth wire |
| 149 | 4X16 sqmm + 2x 6.0 sqmm earth wire |
| 150 | Supplying and drawing following pair 0.5 sqmm FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required. 2 Pair |
| 151 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 152 | Supply and fixing of following size of PVC conduit alongwith the accessories in recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25mm |
| 153 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet |
| 154 | TV antenna socket outlet |
| 155 | Bell Push |
| 156 | Supply and fixing of stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 157 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 158 | Supplying and fixing following size/modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 module(75mm X 75 mm ) |
| 159 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch,connection etc. as required. |
| 160 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,connection etc. as required. |
| 161 | Supplying and fixing 3 pin 5 A ceiling rose on the existing junction box/woodedn block including connectionetc. as required. |
| 162 | Supplying and fixing brass batten/angle holder including connectionetc. as required. |
| 163 | Instalation,testing & commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLSCFL/LED lamps per fitting, complete with all accessories including connection etc. as required. |
| 164 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 165 | Installation, testing and commissioning of prewired, flourescent fitting / compact fluorescent fitting of all types, complete with all accessories and tubes etc. directly on ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single core cable etc. as required. |
| 166 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 167 | Supply and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, `C` curve including connections, painting etc. as required. |
| 168 | Providing and fixing circular/Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screwed, one loc at the conrners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. |
| 169 | Brush Less Direct Current (BLDC) Fan withRemoteSupply, Installation, Testing and Commissioning ofceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 170 | Providing & fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in in existing panel board including drilling holes in cubical panel, making connections,etc as required. 125 A, 36 KA, FPMCCB |
| 171 | 200 A, 36 KA, FPMCCB |
| 172 | Supplying and fixing following way, single pole and neutral sheet steel, MCB distribution board, 240 V on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 8 way, Double door |
| 173 | Supplying and fixing following way, Horizontal type three pole and neutral MCB distribution board, 415 volts on surface /recess complete with , tinned copper busbar, neutral busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB / RCCB / Isolators). 4 way (4 + 12), Double door |
| 174 | 6 way (4 + 18), Double door |
| 175 | Supplying and fixing following way, surface/recess mounting,vertical type 415V, TPN MCB distribution board, on steel sheet, dust protected, duly power painted, inclusive of 200 A tinned copper busbar, common neutral link, earth bar, din bar, for mounting MCBs (But without MCBs and incomer) as required(Note:vertical type MCB TPDB is normally used where 3 phase outles are required.) 8 way (4 + 24), Double door |
| 176 | Supplying and fixing 5 amps. to 32 amps. rating, 240 volts `C' series, miniature circuit breaker (MCB) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole |
| 177 | Double Pole |
| 178 | Supplying and fixing single pole, blanking plate in the existing MCB DB complete etc. as required. |
| 179 | Supply and fixing following rateing four pole, 415 V, isolator in the existing existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 180 | Same as Above but for 63 A |
| 181 | Providing and fixing M.V. danger notice plate of 200 mmx150 mm, made of mild steelm at least 2 mm thick, and viterous enameled whithe on bothe sides, and with incription in single red colour on front side as required. |
| 182 | Suplying and fixing cable end box(Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution borad, 415 Volts, on surface/recess, complete with testing and commissoning ect. As required. For 4 way, Double Door TPNMCBDB |
| 183 | For 6 way, Double Door TPNMCBDB |
| 184 | Supply and installing of following size of perforated Hot Dipped Galvanised Iron cable trays (Galvanisation thickness not less 50 miccrons) with preforation not more than 17.5%, in convenient sections, jointed with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts etc as required 450mm width x 62.5mm depth x 2.0mm thickness |
| 185 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 186 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 187 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 188 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 189 | Above 35 sq. mm and Upto 95 sq. mm. |
| 190 | Above 185 sq. mm and Upto 400 sq. mm. |
| 191 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3.5 X 50 sqmm. (35mm) |
| 192 | 3.5 X 240 sqmm. (62mm) |
| 193 | 2 X 10 sqmm. (19mm) |
| 194 | 4 X 10 sqmm. (25mm) |
| 195 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 196 | PART B - PWD SOR ITEMS CABLES Supply and laying of aluminium conductor PVC insulated armoured served shealth cables 1100V grade at a depth of 750 mm thick sand all around and protected with burnt bricks on sides and top. On surface the cable run shall be fixed with M.S clamps etc of suitable size or as directed by the engineer incharge complete in all respect including excavation and refilling. The armouring of the cable shall be properly connected with the earth condutor by clamps e.t.c 50 sqmm 3.5 core |
| 197 | 240 sqmm 3.5 core |
| 198 | 10 sqmm 4.0 core |
| 199 | MAIN L.T. PANEL Supply and projection of factrory and wired metal wired metal clad dust and vermin proof mountingn. M.S channel Base with bottan and top cable entires Electrical contral panel with Tpn MCCB's(four pole 36Ka with thermal magnatic release)Switches complete and insturment chamber etc. complete in all respects. The instrument chamber shall be separate and shall complate of flush type digital metering system for phase to phase voltage. current and other paraments (Kva.P.f.K.W etc.)in each phase with toche type selector switch for diffrent reading instruments fuses current transformer etc. the panel Board shall have suitable capacity electrolytic aluminum busbars as per is 8623 or above insulated with heat shrink sleeving and mounted on the sides. the MCCB'S shall be completed withsuitable cable end boxes. Compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as Amp and above well be provided with Ammetre. The panel board shall be fabricated with CRCA sheet with Ammetre. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6MM /2MM cubicle type switch shall be L/T or Schnieder of equvalent make. incoming 400 AMP , TPN-1 No. Outgoing 200 Amp. TPN-1 Nos, 100 Amp. TPN-2 Nos. & 63 Amp. TPN-1 Nos. CAT B. Cubicle Type SOR 804 C (ii) |
| 200 | SUPPLY OF LIGHT FIXTURES : Supply and fixing of LED tube light with batten suitable for up 1 x 22 watt LED tube light fitting including tube on surface complete in all respect CAT-AA |
| 201 | Supply of LED Tube Light with batten suitable for up to 2X20 watt LED tube light complete including tube etc. on surface/Pendent complete in all respect.CAT-AAA |
| 202 | Supply and fixing of 12 Watt to 15 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 203 | Supply and fixing of 36 Watt to 46 Watt lumen above 3300 Surface mounting LED Square Celling Fitting having Powder coated die cast aluminium housing body with extended heat sink, diffuser of Polycarbonate meterial and driver set complete in all respect. CAT-AAA |
| 204 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 110 to 130 Watt. Confirming to IP 66 Protection complete in all respect. CAT-AAA |
| 205 | FIRE FIGHTING (A) Supplying, Installation, Testing & Commissioning of Electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required:(Terrace Pump) (C) Suitable HP Squirrel cage indution motor, TEFC type suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, confirming to IS-325. (D) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (E) Suitable cement concrete foundation duly plastered with anti vibration pads. 450 lpm at 35 m head |
| 206 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 25 mm dia |
| 207 | Same as Above but for 100 mm dia |
| 208 | Supplying & fixing single headed internal yard hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required: Single headed Gunmetal |
| 209 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 100 mm dia |
| 210 | Supplying & fixing orifice plate made out of 6 mm thick stainless steel(grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required: |
| 211 | Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia |
| 212 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal |
| 213 | Supplying & fixing First-aid hose Reel with MS construction spray painted in post office red,conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic(Textile reinforced) type-2 as per IS:12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipments on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m |
| 214 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required. Gun Metal |
| 215 | Supplying & fixing air vessel made out of 250 mm dia,8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required. |
| 216 | Providing & fixing of pressure switch in M.S. pipe line including connection etc as required. |
| 217 | Supplying, installation, testing & commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices(including detector) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memroy(EPROM), power supply(230+-5% V, 50hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall to have facility to connect printer to printout log and facikity to seamless integration with analog/digital voice evacuation system(which is part of the schedule of work under SH:PA system) and shall be complete with all accessories. The panel shall be compatible for IBMS system with open protocol BACnet/Modbus over IP complete as per specifications. Two Loop Panel |
| 218 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 219 | Supplying, installation, testing & commissioning responce indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. |
| 220 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 221 | Supplying, installation, testing & commissioning of addressable fire control moudle complete as required. |
| 222 | Supplying, installation, testing & commissioning of addressable phone control moudle complete as required. |
| 223 | Supplying, installation, testing & commissioning of addressable manual call point complete as required. |
| 224 | Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. |
| 225 | Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. |
| 226 | Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. |
| 227 | Supplying & laying of 2X1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. |
| 228 | Supplying & laying 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. |
| 229 | Supply and fixing of following sizes of medium class PVC conduit alongwith the accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required: 25 mm |
| 230 | Providing, laying, testing & Commissioning of 'C' class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 80 mm dia |
| 231 | Same as Above but for 100 mm dia |
| 232 | Supplying & fixing single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, confirming to IS 5290(type A) with blank Gunmetal/Stainless Steel cap and chain as required:Single headed Gunmetal |
| 233 | Supplying, fixing, testing & commission of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets confirming to IS 13095 of following sizes as required: 80 mm dia |
| 234 | 100 mm dia |
| 235 | Providing, installation, testing and commission of non-return valve of following sizes confirming to IS: 5312 complete with rubber gaskets GI bolts, nuts, washers etc as required: 100 mm dia |
| 236 | Supplying & fixing 63 mm dia, 15m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. confirming to IS 636(type-A) as required: Gun Metal |
| 237 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle confirming to IS:903 suitable for instantaneous connection to interconnect hos pipe coupling as required.Gun Metal |
| 238 | Supplying & fixing of Fire brigade connection of cast iron body with gun metal male instantaneous inlet coupling complete with cap and chain as required. for suitable dia MS pipe connection conforming to IS 904 as required: 2 way-100 mm dia M.S. Pipe |
| 239 | Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PWD Elec - 1131(A) |
| 240 | Supply and fixing of CO2 type fire extinguisher 4.5 kg. capacity (ISI Marked) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PWD Elec -1132 |
| 241 | Supply and fixing of bucket, round bottom made of G.I. sheet 9-11 liters capacity duly painted as per fire brigade design supported on hanging bracket chined and locked, initially fitted with fine river sand, water as per directions of engineer in charge. PWD Elec -1133 |
| 242 | TUBWELL BORING Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer-in-charge. Upto 90 metre depth below ground level. |
| 243 | Beyond 90 metre & upto 150 metre depth below ground level. |
| 244 | Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia,conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 245 | Supplying, assembling, lowering and fixing in vertical position in bore wellunplasticized PVC medium well screen (RMS) pipes with ribs, conformingto IS: 12818, including hire & labour charges, fittings & accessories etc.all complete, for all depths, as per direction of Engineer-in-charge. 150 mm nominal size dia |
| 246 | Supplying, filling, spreading & leveling coarse sand of size range 1.5 mmto 2 mm in recharge pit, in required thickness over gravel layer, for all leads& lifts, all complete as per direction of Engineer -in-charge. |
| 247 | Development of tube well in accordance with IS : 2800 (part I) and IS:11189, to establish maximum rate of usable water yield without sandcontent (beyond permissible limit), with required capacity air compressor,running the compressor for required time till well is fully developed,measuring yield of well by “V” notch method or any other approved method,measuring static level & draw down etc. by step draw down method,collecting water samples & getting tested in approved laboratory, i/cdisinfection of tubewell, all complete, including hire & labour charges ofair compressor, tools & accessories etc., all as per requirement anddirection of Engineer-in-charge. |
| 248 | Providing and fixing M.S. clamp of required dia to the top of casing/housingpipe of tubewell as per IS: 2800 (part I), including necessary bolts & nutsf required size complete.200 mm nominal size dia |
| 249 | Providing and fixing Bail plug /Bottam plug of required dia to the bottam of pipe assembly of tubewell as per IS:2800 (PART-1) 150 mm nominal size dia |
| 250 | Providing and fixing C.I. sluice valve . 100 mm nominal bore. Class I |
| 251 | Providing and fixing G.I. pipes complete with G.I. fittings including trenchingand refilling etc. 65 mm dia nominal bore Boring to building |
| 252 | Column Pipe |
| 253 | Water supply tanker of 10000 litre capacity |
| 254 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge ,complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 35 sq. mm 3-1/2 core |
| 255 | SCHEDULE OF QUANTITIES FOR EXTERNAL SEWERAGE SYSTEM Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures's permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. |
| 256 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) cement plastered on both sides with cement mortar ( 1 cement : 3 coarse sand) finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250mm diameter |
| 257 | TOTAL EXTERNAL SEWERAGE SYSTEM Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m. including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. Pipes, cables etc. not exceeding 80mm dia. |
| 258 | Provding and fixing gun metal non return valve of approved quality (screwed end) 65 mm nominal bore Vertical |
| 259 | Providing & fixing G.I. pipes complete with G.I. fittings including tenching and refilling etc. External work 25mm nominal bore. |
| 260 | 50mm nominal bore. |
| 261 | 65mm nominal bore. |
| 262 | Providing & fixing sand of grading zone V or coaser grade alround the G.I. Pipes in external work.25 mm diameter pipe |
| 263 | 50 mm diameter pipe |
| 264 | 65mm diameter pipe |
| 265 | Providing and fixing gate valve (with cap complete with bolts, nuts, rubber insertion etc. 25 mm nominal bore |
| 266 | 50 mm nominal bore |
| 267 | 65 mm nominal bore |
| 268 | Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks |
| 269 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm dia nominal bore |
| 270 | 50 to 80 mm dia nominal bore |
| 271 | Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded sotne aggregate 40mm nominal size) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. |
| 272 | Painting with aluminium paint of approved brand and manufacture to given an even shed. Two or more coats on new work |
| 273 | Supplying and embedding following dia G.I. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required. 40mm dia |
| 274 | Supplying and drawing following size of FRLS PVC insulated copper conductor, single core cable in existing surface/ recessed medium class PVC conduit as required. 3X2.5 sqmm |
| 275 | Earthing with GI earth pipe, 600 mm X 600 mm X 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc, with charcoal/cock and salt as required. |
| 276 | Supplying and Laying of 25 mm X 3 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required.( jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 277 | Supplying and Laying of 6 SWG G.I wire at 0.50 metre below ground level for conductor earth electrode, including connection / terminating with G.I. thimble etc. as required. |
| 278 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm |
| 279 | Above 185 sq. mm and Upto 400 sq. mm. |
| 280 | Supplying & making end termination with brass compression gland and aluminium lugs for the following size of PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 2 X 6 sqmm. (19mm) |
| 281 | 2 X 10 sqmm. (19mm) |
| 282 | 4 X 10 sqmm. (25mm) |
| 283 | 3.5 X 240 sqmm. (62mm) |
| 284 | 3.5 X 300 sqmm. (70mm) |
| 285 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 286 | Supplying, installation, testing & commissioning of Astronomical time switch of following configuration to be mounted in feeder pillars/lighting DBs for automatic switching On & Off of street lights at sunset & sun risr or twillight(Auto On, Auto Off, Auto modes) with manual override facility with 12/24 hour display format with suitable battery and indication for relay status i/c progamming at site complete required.02 output per phase and suitable for single phase supply |
| 287 | PART B - SOR ITEMS (AS PER MARKET RATES) CABLES Supply and laying and fixing of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on cable tray as required. 6 sqmm 2 core |
| 288 | 10 sqmm 2 core |
| 289 | 10 sqmm 4 core |
| 290 | 240 sqmm 3.5 core |
| 291 | 300 sqmm 3.5 core |
| 292 | L.T. FEEDER PILLAR-1 Supply and projection of factrory and wired metal wired metal clad dust and vermin proof mountingn. M.S channel Base with bottan and top cable entires Electrical contral panel with Tpn MCCB's(four pole 36Ka with thermal magnatic release)Switches complete and insturment chamber etc. complete in all respects. The instrument chamber shall be separate and shall complate of flush type digital metering system for phase to phase voltage. current and other paraments (Kva.P.f.K.W etc.)in each phase with toche type selector switch for diffrent reading instruments fuses current transformer etc. the panel Board shall have suitable capacity electrolytic aluminum busbars as per is 8623 or above insulated with heat shrink sleeving and mounted on the sides. the MCCB'S shall be completed withsuitable cable end boxes. Compression glands and indicating lamp on incoming etc. The job includes the grounting of the board as Amp and above well be provided with Ammetre. The panel board shall be fabricated with CRCA sheet with Ammetre. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6MM /2MM cubicle type switch shall be L/T or Schnieder of equvalent make. incoming 400 AMP , TPN-1 No. Incoming : 1No. Of 400 Amps TPN MCCB of 36 KA service breaking capacity and 400 Amp trip setting. Metering : Voltmeter, Ammeter, Indication Bus Bar : 1 Set of 400 Amps TPN Aluminium Bus Bars of suitable length and of cross section . Bus bar shall be insulated by heat shrinkable sleaves & clip on shrouds for joints. Bus bar shall be designed to with stand a fault level of 36 KA at 415 volts. 3Nos. Phase indicating lamp each lamp shall have one toggle switch . Outgoing : Phase indication lamps on each outgoing to be provided. 315Amp TPN MCCB -1Nos. 100Amp TPN MCB -2Nos. 63Amp TPN MCB -1Nos. |
| 293 | SUPPLY OF LIGHT FIXTURES : Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect.CAT-AAA |
| 294 | SEPTIC TANK & SOAKPIT Providing and fixing C.I. tee at the inlet and outlet of septic tank. |
| 295 | Providing & fixing 75mm dia vent pipes. Sand cast iron S&S pipe as per IS: 1729 |
| 296 | Providing & fixing of 75mm dia cast iron terminal guard. Sand cast iron S&S as per IS - 1729 |
| 297 | Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality. L.D. -2.5- Circular shape 450mm internal diameter |
| 298 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design. With F.P.S. bricks Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail