| 1 | Taking down cement plaster on brick walls or concrete surface including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and as directed. |
| 2 | M&L for rendering 10 mm thick on fair faces of bricks or concrete surfaces as in ceiling surfaces in cement mortar 1:3 finished even & fair all as specified and as directed. |
| 3 | M&L, 15 mm thick rendering in CM 1:4 on other then fair faces surface with water proofing compound lquid type @ 0.200 ml / 50 kg of cement bag to brick/concrete surfaces trowelled to even & smooth without using extra cement complete |
| 4 | M&L, 15 mm thick rendering in CM 1:4 on other then fair faces surface on brick/concrete surfaces trowelled to even & smooth without using extra cement complete |
| 5 | M&L for Rendering 10mm thick on fair faces of brick work or concrete surfaces of in cement mortar 1:6 finished even and fair complete all as specified and as directed. |
| 6 | M&L preparation of newly plastered surfaces of walls, and applying two coats of oil bound distember over a coat of alkali resistant primer complete all as specified and as directed. |
| 7 | M&L preparation of newly plastered surfaces of walls and applying two coats of cement base paint white or tinted over a coat of primer complete all as specified and as directed. |
| 8 | M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed. |
| 9 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and as directed. |
| 10 | M&L for 20 mm thick Granite(of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over and including 15 mm thick screed bed in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 11 | Dismantling of Asbestos Cement (corrugated or semi-corrugated) sheets in roof covering including ridges, hips, valleys and flashings etc complete all as specified and as directed. |
| 12 | S&F Pre-painted galvalume aluminum zinc coating GI based semi-corrugated steel sheet 0.50mm thick red colour having tensile strength of 550 Mpa as per IS 15965: 2012 and coating AZ-150 in roof covering/cladding to wall fixed with self tapping screws complete all as specified and as directed. |
| 13 | S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of red colour having tensile strength of 550 Mpa as per IS 15965: 2012 as in ridge fixed with self tapping screws complete all as specified and as directed. |
| 14 | Dismantling timber scantlings 40sqcm and over in section, in any position in framed work complete all as specified and as directed. |
| 15 | M&L for Mild steel work angle / hollow section in purlins, rafter including special shaped washer, angle cleats, fish plates, gusset plates, base/ bearing plates, bolts and nuts etc. complete using ERW or induction butt welded tubes conforming to 1161-1979 grade st 240 complete all as specified and as directed. |
| 16 | Dismantling wall and ceiling boards (fiber, pulp, insulation, etc) or insulation board/slabs/blankets, any thickness, including cover fillets and any type frame work complete all as specified and as directed. |
| 17 | S&F anodised grid (of size 605 mm x 605 mm) frame for false ceiling including providing hangers of 1.5-2 mm GI wire (upto 1200mm length) adjusting level fixed to roof slabs or ceiling cleats made out of GI flat 40x3mm size 60mm long fixed with expansion hold fasteners 12.5mm dia 40mm long complete all as specified and as directed. |
| 18 | M&L for 4 mm thick non-asbestos fibre cement building board and fixed on aluminium grid with screws complete all as specified and as directed. |
| 19 | S&F hollow PVC Wall fluted panel / louvers consisting of 5 mm thick plain/digital colour PVC sheet inclusive of solvent cement and fixed with PVC plug and screw and inserted to next panel groove edge and corners of all door window opening etc to be covered with pvc angle fixed at site as per manufacture instruction complete all as specified and as directed.. |
| 20 | M&l for preparation of new steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 21 | Dismantling of existing floor any type and cleaning existing concrete surface by brushing with wire brushed for removing caked mud etc, sweeping with brooms and reomve all loose dirt etc |
| 22 | Demolition of unreinforcement cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 23 | M&L for 75 mm thick cement concrete type D2 1:4:8 (using 40mm graded stone aggregate) as in sub base, Sub floor, foors and paving for increasing the height of floor as ground condition etc complete all as specified and as directed. |
| 24 | M&L non skid parking tiles coloured tiles 9-10 mm thick (square/rectangular) area of each exc 0.11 Sqm but n. exc. 0.18 Sqm as in floors set and jointed in neat cement slurry & pointed with coloured cement to match the colour of tiles laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 25 | M&L non skid parking tiles coloured tiles 7-8mm thick (square/rectangular) area of each exc 0.06 Sqm but n. exc. 0.11 Sqm as in floors set and jointed in neat cement slurry & pointed with coloured cement to match the colour of tiles laid over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and as directed. |
| 26 | M&L for 80 mm factory made chamfered edge precast concrete interlocking paver blocks any shape and size locally available of best quality and confirming to IS 15658-2006 , M-30 Grade with grey cement and pigments with appproved colour design &pattern as in footpath, parks, lawan,or light traffic ways of required strength made by table vibratory method using PU mould laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, compacted and proper embedding /laying of inter locking paver block into the sand bedding layer through vibratory compaction by using plate vibrator filling the joints with fine sand and cutting of paver block as per required size and pattern finishing and sweeping extra sand complte grey cement and pigments complete all as specified and as directed. |
| 27 | Demolition of existing roof treatment (Mud phuska, /APP membrane complete complete of any thicknesss and in any position and removing the demolished material out of MoD land complete all as specified and as directed. |
| 28 | M&L for water proofing treatment using APP based polymeric membrane not less than 3 mm thick, weighing not less then 3.00 kg / Sqm, reinforeced with polyster non-woven fabric (weighing not less than 150 gm/sqm) laid over cold bitumen primer applied at the rate of 0.30 kg/sqm by forced application over roof / terrace complete all as specified and as directed. |
| 29 | M & L for applying of tack coat of industrial bitumen 85/25 @ 1.20 kg/sqm including cleaning of old surface complete all as specified and as directed. |
| 30 | M&L for cement concrete tiles 20cm x 20cm x 20mm thick, with grey cement and no pigments, machine pressed, set jointed and pointed in neat cement slurry in floor laid over and including 15 mm thick screed bed in cement mortar 1:6 and filling the joints with Tile Mix premium cementitious grout material or its equivalent complete all as specified and as directed. |
| 31 | Demolition of brick work or stone/boulder masonary, buit in cement mortor or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and as directed. |
| 32 | M&L for brick work with old size Bricks sub class B, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 33 | M&L for machine cut kota stone flooring 20-22mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing over and including 20 mm thick screed bed in CM 1:4 complete |
| 34 | M&L for machine cut kota sone slab 18-20mm thick in skirting, dado and pillar laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing over and including 10mm thick rendering in CM 1:3 complete |
| 35 | S&F MS Framed work such as grills gratings, door and cooler stand, ladders,Monkey cage etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars confirming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 36 | Dismantling wrought iron or mild steel work of any description not otherwise provided for |
| 37 | S&F welded steel wire fabric of weight n exc 4 kg per Square metre supplied and fixed complete to wood or steel members complete all as specified and as directed. Please Enable Macros to View BoQ information |