| Sl. No. | Item Description |
| 1 | DISMANTLING, DEMOLISHING & REPAIRINGDemolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. |
| 2 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge |
| 3 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 4 | Dismantling doors, windows, ventilators and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.Of area 3sqm and below |
| 5 | Of area beyond 3 sqm |
| 6 | Dismantling steel work including dismembering complete including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 7 | Demolishing existing water proofing in terracing complete in all the respect and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 8 | Dismantling wood work in frames, structures, etc. for all heights including disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 9 | Demolishing dry brick pitching in floors, drains etc. including stacking of serviceable material and disposal of unserviceable material within 50 metres lead |
| 10 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 11 | Dismantling rain water pipes for all dia. with fittings and clamps ncluding stacking of serviceable material per direction of Engineer-in-charge and disposal of unserviceable material within 50 metres lead |
| 12 | Dismantling G.I. pipes including excavation and refilling trenches if required after taking out the pipes, manually/ by mechanical means including stacking of pipes as per direction of Engineer-in-charge. |
| 13 | Dismantling C.I. pipes including excavation and refilling trenches if required after taking out the pipes, manually/ by mechanical means including stacking of pipes & lead at site as per direction of Engineer-in-charge. |
| 14 | Dismantling of gully chamber and soak pit of various sizes including C.I. Grating or cover with frame including stacking of useful materials as per direction of Engineer-in-charge and disposal of unserviceable material within 50 metres lead |
| 15 | Dismantling of sanitary items (wash basin/water closet/urinals/shower heads/taps, etc.) of all types including all fittings and stacking of useful materials as per direction of Engineer-in-charge and disposal of unserviceable material within 50 metres lead |
| 16 | Dismantling false ceiling including disposal of unserviceable material and stacking of useful materials as per direction of Engineer-in-charge and disposal of unserviceable material within 50 metres lead |
| 17 | Repairs to plaster of any thickness in patches, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of unserviceable material within 50 metres leadWith cement mortar 1:4 (1cement: 4 coarse sand) |
| 18 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet |
| 19 | Asbestos Cement sheet |
| 20 | Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/ masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) |
| 21 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting,unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved |
| 22 | EARTH WORK:Earthwork in excavation in foundations of buildings, footings, columns, plinth beams, walls, machine/ equipment foundations, isolated pits, pavements, trenches for pipelines /cables, pipe sleepers, drains, etc., to the required levels and grades in both dry and wet conditions, including dressing of sides and ramming of bottoms, getting out excavated earth with lift upto 1.5 M and disposal of surplus excavated materials within a lead of 50 M including stacking, levelling and dressing etc., complete as per direction of Engineer-in-Charge(E.I.C.) in all kinds of soils as defined in IS: 1200 including providing temporary supports to all service lines such as overhead and underground water, sewage and drain pipes, cables etc. and shoring and strutting wherever necessary, complete in all respects as per direction of Engineer-in-Charge. |
| 23 | Same as Item No. A-01, but lift from 1.5 M to 3.0 M. |
| 24 | Same as Item No. A-01, but lift from 3.0 M to 4.5 M |
| 25 | Filling with available excavated good earth (excluding rocks / boulders), as approved and directed by Engineer-in-Charge, in trenches, plinth, under floors, sides of foundation etc., at all depths in layers not exceeding 20 cms. in thickness including consolidating and dressing each deposited layer by ramming and watering with lead upto 50 metres, complete in all respects (compaction under floor with mechanical vibrater / road roller including watering). |
| 26 | Filling / banking the proposed area with earth excavated from owner's premises (5 km lead) to the required grade levels in layers not exceeding 20 cm in depth including excavation, loading, unloading, filling, spreading, breaking clods, watering, leveling at site area, consolidating / compacting each deposited layerwith minimum 8.0 Tonne capacity power roller up to 95% of maximum dry density of filling materials, dressing up the embankments for flood banks, marginal banks, and guide banks etc., grading area within the plant boundary and at all lifts, removal of rubbish / debris to a location outside the periphery of the Plant Battery Limits to the approved municipal ground (responsibility lies with the contactor to obtain permission from municipal corporation) / contactor own premises outsdie plant leaving the site clear and providing tests for required compaction of the surfaces etc., in all kinds of soil complete, as per specifications for all lifts involved, approved drawings and as directed by Engineer-in-Charge. Note: Jungle clearing & surface dressing, if requried, shall be paid under separate item. |
| 27 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish to the approved municipal dumping ground (reponsibility of seeking permission from municipal corporation shall be of contractor) or contractor's own land. |
| 28 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings including removal of rubbish up to to the approved municipal ground (responsibility lies with the contactor to obtain permission from municipal corporation) / contactor own land as directed by Engineer-in-Charge. |
| 29 | PLAIN CEMENT CONCRETE:Providing and laying plain cement concrete, machine mixed and mechanically vibrated in foundations, plinth, under floors, etc., including all necessary cost of centring and shuttering :1:4:8 (1 cement: 4 coarse sand: 8 graded stone aggregate 40 mm nominal size). |
| 30 | Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20mm nominal size). |
| 31 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. |
| 32 | IN FOUNDATION AND PLINTHProviding and laying reinforced cement concrete of grade M-30(using 20 mm. nominal gauge graded stone aggregate) machine mixed and mechanically vibrated and finished to a fair face but excluding the cost of centring, shuttering and reinforcement in foundation and plinth, for rafts, footings, bases of columns, pedestals, beams, walls, columns, slabs, machine and equipment foundations, pile caps, box sections, pipe supports, etc., complete in all respects as per direction of Engineer-in- Charge. |
| 33 | Same as Item No. C- 01, but with concrete of grade M-25. |
| 34 | IN SUPERSTRUCTUREProviding and laying reinforced cement concrete of grade M-30 ( using 20 mm. nominal gauge graded stone aggregate), machine mixed, mechanically vibrated and finished to a fair face but excluding the cost of centring, shuttering and reinforcement in superstructure at all heights for columns, pillars, posts, attached pillasters, portals, struts, inclined posts, pedestals for equipments and similar vertical members, etc., complete in all respects as per direction of Engineer-in-Charge. |
| 35 | Providing, hoisting and fixing precast reinforced cement concrete work including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).Trench/ drain covers, in foundation, plinth and above. |
| 36 | REINFORCEMENT AND EMBEDMENTS:Supplying, cutting, cleaning, straightening, bending, hoisting and placing in position and binding with 18 SWG annealed wire, reinforcement bar of high yield strength Corrosion Resistance Steel with Fe500D properties conforming to IS:1786 with minimum yield strength of 500 N/sq,mm for all R.C.C. works including all necessary handling at all heights and depths complete in all respects and as per direction of Engineer-in-Charge. |
| 37 | Supplying, fabricating and fixing in position M.S. anchor plates, hooks, insert plates, M.S. flats, M.S. angle inserts and the like including welding M.S. lugs, etc., and embedding in cement concrete /R.C.C. works as per approved drawings complete in all respects and as per direction of Engineer-in-Charge. |
| 38 | SHUTTERING:Providing, fabricating, erecting and fixing in position with bolts and nuts, nails and ties, etc., centring and shuttering materials true to line and level, including strutting, propping, staging etc. with necessary bracing in all axes to give a stable assembly including chamfering the corners of columns and beams etc., wherever required including making joints in the shuttering fully leak-proof, i/c. Striking, dismantling and removing the aforesaid assembly after concreting is over, including all labour and materials complete in all respects and as per direction of Engineer-in-Charge :IN FOUNDATION AND PLINTHFoundation and plinth in rafts, footings, columns, pedestals, beams, walls, slabs, machine and equipment foundations, pile caps and pipe support foundations, etc. |
| 39 | IN SUPERSTRUCTUREColumns, pillars, posts, struts, inclined posts, attached anufactu, portals and similar vertical members. |
| 40 | Walls of any thickness, height and shape including attached buttresses, anufactu, and their caps and bases, etc. |
| 41 | Lintels, beams, portal beams, brackets, girders, cantilever beams, suspended floors, roofs, staircase roofs and their supports, balconies, staircase waist and landing slabs and steps, etc. |
| 42 | Chajja, vertical and horizontal fins, roof gutters, drop walls, railing, parapet wall, window sills, etc. |
| 43 | BRICK WORK:Providing and constructing brick work using bricks of class designation 7.5 in cement mortar 1 : 6 ( 1 cement: 6 coarse sand ) in: Foundation and plinth. |
| 44 | Superstructure at all heights. |
| 45 | Half brick masonry with bricks of class designation 7.5 in plinth and super structure in cement mortar 1:4 ( 1 cement : 4 coarse sand) |
| 46 | STRUCTURAL STEEL:Supplying, transporting, de-rusting, fabricating, erecting, hoisting and fixing in position with necessary welding and/or bolting with MS bolts conforming to property class 8.8 of IS: 1367 at all heights as per approved fabrication drawings of all types of structural steel work in columns, portals, girders, lattice girders, beams, crane girders, M.S rails, monorails, bracings, trusses, purlins, rafters, side runners, sag rods, hand railings, staircase stringers and steps, walkway, toe-plates, floor grids, sag rods with M.S. rounds, side walling, conveyor gantries, trestle for pipe and cable racks, gusset plates, etc., either made of rolled steel joists, channels, angles, tees, flats, plates , universal sections or built up from plates and/or rolled steel sections including necessary site and shop fasteners, complete in all respects as per approved fabrication drawings, standards and direction of Engineer-in-Charge :With providing and applying primer coat, intermediate coats and finish coat after the preparation of surfaces on structural steel work complete in all respects as per technical specifications and direction of Engineer-in-Charge. |
| 47 | Supplying, transporting, de-rusting, cutting and fixing in position at all heights steel work in M.S. chequered plates in floors, steps, landing, covers over trenches, etc., with necessary bolts, nuts, washers, drilling holes, welding, etc., wherever necessary as per drawing including painting complete in all respects and as directed by Engineer-in Charge :Two coats of chlorinated rubber based paint at dry film thickness of 50 microns per coat over two coats of high built zinc phosphate primer compatible to chlorinated rubber based paint at dry film thickness of 50 microns per coat. |
| 48 | Structural steel work in single section, fixed with or without connectingplate,including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 49 | DOORS, WINDOWS AND VENTILATORS:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 50 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPD M rubber / neoprene gasket required including necessary fittings. Powder coated aluminium (minimum thickness of powder coating 50 micron |
| 51 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-in-charge. (Including aluminium snap beading)With float glass panes of 4.0 mm thickness |
| 52 | With float glass panes of 5.50 mm thickness |
| 53 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight up to 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete asper the direction of Engineer-in-charge.With stainless steel cover plate minimum 1.25 mm thickness |
| 54 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- chargeExtruded section profile size 42x50 mm |
| 55 | 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness, fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge. (For W.C. and bathroom door shutter). |
| 56 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length inclduing all fittings and fixtures complete.Kiln seasoned and chemically treated hollock wood |
| 57 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core of block board onstruction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 58 | Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for doors including necessary cutting and making good etc. complete. |
| 59 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. |
| 60 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture. |
| 61 | ROOFING:Providing and fixing in position at all heights UPVC rain water pipes confirming to BIS :13592 Type A R.C.C. column using plugs and standard holder bat clamps comprising of two semi-circular halves of flat iron and cast iron base screwed on wooden plugs or using clamps welded to structural steel members or M.S. insert plates where pipes are to be fixed on R.C.C. members including all necessary fittings, such as tees, shoes, off-sets, branches, swan necks, elbows, bends, heads, etc. (plate inserts, if any, to be embedded in R.C.C shall be paid separately).110 mm diameter pipe. |
| 62 | Provided and fixing asbestos cement 6 mm thick corrogated in sheet in roofing & side clading and fixing with GI J & L hook, bolt and nut, 8mm dia including GI plain and bitumen washers complete at all height excluding the cost of purline, rafter trusses. |
| 63 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto anypitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 64 | Providing and fixing false ceiling at all heights with integral densifiedcalcium silicate reinforced with fibre and natural filler false ceilingtiles of Size 595x595 mm of approved texture, design and patterns having NRC (Noise Reduction coefficient) of 0.50 (minimum) as perIS 8225:1987, Light reflectance of 85% (minimum). Non combustibleas per BS:476 (part-4), fire performance as per BS:476 (part 6 &7),humidity resistance of 100%, thermal conductivity < 0.043 W/m Kas per ASTM 518:1991, in true horizontal level suspended on inter-locking metal powder coated T-Grid of hot dipped galvanised ironsection of 0.40 mm thick on Silhouette profile,rotary stiched doublewebbed white with 6 mm reveal profile (white/black),comprising ofmain-T runners of size 15x42 mm of length 3000 mm, cross - T ofsize 15x42 mm of length 1200 mm and secondary intermediatecross-T of size 15x42 mm of length 600mm to form grid module ofsize 600 x 600 mm, suspended from ceiling using galvanised mildsteel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8mm outer diameter M-6 dash fasteners, 6 mm dia fully threadedhanger rod upto 1000 mm length and L-shape level adjuster of size85x25x2 mm. Galvanised iron perimeter wall angle of size22x19x0.40 mm of length 3000 mm to be fixed on periphery wall /partition with the help of plastic rawl plugs at 450 mm center tocenter and 40mm long dry wall S.S screws. The work shall be carriedout as per specifications, drawing and as per directions of theEngineer-in-Charge.With 15 mm thick integral densified micro edge lightweight calcium silicate false ceiling tiles |
| 65 | Painting on structural steel & sheeting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade (old & new work). |
| 66 | WATER PROOFING:Clearing the roof surface wherever required by manual scrapping/chipping to take out loose mortar, laitance etc. to expose the mother R.C.C roof surface. At the junction between the roof and the vertical face of the parapet wall a fillet 75mm (min.) in radius shall be constructed to receive the waterproofing treatment. In case of RCC parapet walls for taking in the waterproofing treatment a horizontal groove shall be left in the vertical face at the time of construction or made by using electrically operated cutter. |
| 67 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at 25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical 1155 SUB HEAD : 14- REPAIRS TO BUILDING parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 68 | FLOORS AND BASES:Supplying and laying hard core under floors including watering, ramming, bliding and well consolidating with broken stone aggregates 90 mm to 45 mm in layers of maximum compacted thickness of 150 mm including filling the voids with smaller stone chips and with blinding materials fine river sand, (Payment shall be made for finished thickness of hard core) Consolidation by mechanical equipment. |
| 69 | Providing and laying reinforced cement concrete of grade M-20 in pavement floors in plant areas(using 20 mm. nominal gauge graded stone aggregate) machine mixed and mechanically vibrated and finished to a fair face but excluding the cost of centring, shuttering and reinforcement in slabs at ground floor level. Floors are to be cast in the panel of 3 metre x 3 metre with broom finish and painting side surfaces with two coats of bitumen paint of approved quality, complete in all respects as per direction of Engineer-in-Charge. |
| 70 | Providing, laying and fixing the tiles of approved quality and make in cement mortar 1:3 including 20 mm thick mortar bed, filling joints with cement admixed with matching pigments and cleaning etc. Complete as directed- polished vitrified tiles of min size 600mm X 1200mm mirror polish 8-10 mm thk. Tiles should be first quality full body vitrified tiles; Colour and design approved by Engineer-in-charge. |
| 71 | Same as above but in skirting, 100mm high laid flush with the plastered /painted surface, as approved by Engineer-in-charge. |
| 72 | Providing and laying non-skid Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigment etc., complete. |
| 73 | Providing and laying 1st quality ceramic tiles of minimum thickness 5 mm of size : 300MM X 450MM, of approved quality / make/finish on 20mm thick 1:4 (1 cement : 4 coarse sand) mortar bedding for dado including finishing of joints with white / pigment of matching shade etc. complete, as approved by Engineer in-charge. |
| 74 | Providing and laying in position at all heights 25 mm thick Kota stone tiles in flooring and trades over 20 mm (Average) thick base of cement mortar 1:4 (1 cement: 4 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the tiles including rubbing and polishing complete. |
| 75 | Providing and fixing in position at all heights Kota stone tiles 25 mm thick in risers of steps for skirting/dado laid on 12 mm (Average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the tiles including rubbing, polishing, etc., complete in all respects |
| 76 | Extra for nosing trades of steps of kota stone slab. Job included full round moulding of kota stone slab with mirror polishing by hand grinding machine etc. complete & as directed by Engineer-in-charge. |
| 77 | Granite of any colour and shade |
| 78 | FINISHING :Providing at all heights 12 mm thick cement plaster on brick work, exposed surfaces of RCC lintels, beams, etc., complete in all respects and as directed with cement plaster mix : 1:2:2 (1 cement: 2 fine sand: 2 coarse sand). |
| 79 | Providing at all heights 15 mm thick cement plaster on rough side of single or half brick walls, etc., complete in all respects and as directed with cement plaster mix : 1:2:2 (1 cement: 2 fine sand: 2 coarse sand). |
| 80 | Providing at all heights 6 mm thick cement plaster to ceiling, etc., complete in all respects and as directed with cement plaster mix : 1:3 (1 cement: 3 fine sand) |
| 81 | Providing and applying Acrylic Smooth exterior paint of required shade of approved brand n make on exterior walls (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied@ 2.20 kg/10 sqm)). The job includes preparation of surface to make good the unevenness of the surfaces, removing existing paint or putty including necessary scaffolding etc. complete for all heights as directed & instructed by engineer-in-charge. |
| 82 | Providing and applying distempering with oil bound washable distemper of approved brand and manufacture to give an even shade with good quality acrylic washable distemper (readymade) of approved manufacture's specification. Two or more coats on new work. The job includes preparation of surface, providing and applying manufacture's approved distemper primer and applying two coat of putty to make good the unevenness of the surfaces including necessary scaffolding etc. complete for all heights. As per and as directed & instructed by engineer-in-charge |
| 83 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats including primer. |
| 84 | Providing and applying plaster of paris putty of 2 mm thickness removing existing paint or putty to prepare the surface even and smooth complete. |
| 85 | SANITARY WORK:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P.brass pillar taps |
| 86 | Providing and fixing coloured vitreous European type water closet with 8-10 ltr flushing cistern with seat, lid, C.P brass hings and rubber buffers with overflow arrangement with specials of standard make and mosquito proof coupling of approved design complete including painting of fitting and brackets cutting and making good the walls and floors wherever required. |
| 87 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 88 | Providing & fixing SS Nahani Traps. The work shall include fixing the trap in P.C.C. 1:2:4, and shall be provided with Chromium plated brass hinged type heavy grating on the top. The deep seal traps shall have generally 50mm water seal, as required complete in all respect. |
| 89 | Providing and fixing SS bib cock (of 15 mm nominal bore) of approved quality conforming to IS:8931 :Short body bib cock |
| 90 | SS Health Faucets |
| 91 | Providing and fixing SS stop cock (concealed) of standard design and of approved make conforming to IS:8931. |
| 92 | Providing and erecting readymade storage tanks of 'Sintex' or approved manufacturer and required size for capacity 1000 Lit including connecting necessary supply lines, delivery lines, wash water line and with manhole cover at top of not less than 450mm clear dia, with locking arrangement complete as per drawing and as directed and instructed by Engineer-In-Charge. |
| 93 | Providing and fixing angle valve of approved quality (15 mm nominal bore) |
| 94 | Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks ofclass designation 7.5 |
| 95 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes, fittings & including all fixtures with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.15 mm nominal outer dia Pipes |
| 96 | 20 mm nominal outer dia Pipes |
| 97 | 25 mm nominal outer dia Pipes |
| 98 | Providing and fixing soil/ waste PVC pipes as required connecting properly with pipe and filling all joints as required at any level (including tees, bends, plain junction, stays & clamps and other fixtures as required complete in all respect75 mm dia. |
| 99 | 100 mm dia. |
| 100 | Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 101 | Providing and fixing toilet paper holder of approved make. |
| 102 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings completeFlexible pipe- 32 mm dia |
| 103 | Providing and fixing SS make liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 104 | Providing and fixing SS towel rail complete with brackets fixed to wooden cleats with screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms |
| 105 | Providing and fixing SS shower rose with 15 or 20 mm inlet - 150 mm diameter |
| 106 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 250 mm |
| 107 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore |
| 108 | MISCELLANEOUS : Supplying and filling in under floors, etc., with fine sand at all depths in layers not exceeding 20cms. in thickness including consolidating and dressing each deposited layer by ramming and watering, etc., complete in all respects as per direction of Engineer-in-Charge. |
| 109 | Providing, hoisting and fixing precast reinforced cement concrete work including the cost of required centering, shuttering but, excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 110 | Providing and fixing 16 mm M.S. Fan clamps of standard shape andsize in existing R.C.C. slab, including cutting chase, anchoring clampto reinforcement bar, including cleaning, refilling, making good thechase with matching concrete, plastering and painting the exposedportion of the clamps complete. |
| 111 | Providing and fixing in position 12 mm thick bitumen impregnated fibre board conforming to IS: 1838 in expansion joints including sealing the joints at the exposed ends with approved quality sealing compound including application of an approved primer as per manufacturer's specifica- tions and as per direction of the Engineer-in-Charge. |
| 112 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with cement mortar and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 113 | Providing, fabricating and fixing in position gates of any height with one wicket door within the main gate, all made out of structural steel sections such as M.S. Angles, Tees, Channels, Plates, Flats, etc., for all horizontal, vertical and diagonal members, M.S. Gusset plates including providing and fixing in position at all heights hard drawn steel wire fabric mesh of size 75 mm x 25 mm welded with frames, including providing and fixing necessary lock plate, handles, locking arrangement and other fittings, drilling of holes wherever required, welding etc. including providing necessary hinge plates welded to insert plates embedded in RCC columns, bolts and nuts for hinge etc. including providing and applying painting, complete in all respects as per drawings and direction of Engineer-in-Charge.With providing and applying two coats of high build zinc phosphate primer of approved brand and manufacture compatible to chlorinated rubber paint at a dry film thickness of 40 micron per coat on structural steel work after preparation of surfaces including providing and applying two coats of chlorinated rubber based paint of approved colour, brand and manufacture at a dry film thickness of 50 microns per coat (Surface preparation by sand blasting/ power driven brashes will be paid separately). |
| 114 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge.Made of G.I. wire of dia 4 mm |
| 115 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.Chain link fencing |
| 116 | Providing and laying anti-shrinkage grouting in pockets and base plates of light dynamic machines such as small pumps and compressors as per manufacturer's specifications, complete in all respects as per direction of Engineer-in-Charge. |
| 117 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 118 | Anti-Termite Treatment : Supplying chemical emulsion in sealed containers including delivery as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20% |
| 119 | Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.: With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration |
| 120 | DISTRIBUTION BOARD (MPDBs/FPB/DB) Supplying, installing, testing and commissioning of following capacity TPN distribution tap off box made of 1.6mm thick sheet steel enclosure duly painted with powder coating on existing rising mains complete with HRC fuses, interconnections, earthing etc. as required.32 amps TPN, 8 way |
| 121 | 16 amps TPN, 6 way |
| 122 | 16 amps TPN, 4 way |
| 123 | SUB DISTRIBUTION BOARDSupplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's (but without MCB's and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), Double door |
| 124 | 6 way (4 + 18), Double door |
| 125 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole |
| 126 | Triple pole and neutral |
| 127 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 128 | 40 amps |
| 129 | POINT WIRING (including supply)Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A |
| 130 | Group B |
| 131 | Group C |
| 132 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 133 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 134 | TV POINTSupplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 135 | Telephone PointSupplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair |
| 136 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 137 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 138 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 139 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 140 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 141 | 2 way 5/6 amps switch |
| 142 | TV antenna socket outlet |
| 143 | LIGHTINGSupplying fitting & fixing of Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver. 18 W Havells |
| 144 | Supplying and fixing of die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting.JETAALBAFLOODLIGHT80W |
| 145 | Supplying fitting & fixing of Basic all purpose surface and wall mounted LED batten with polycarbonate housing & integrated electronic driver. 9 W Havells |
| 146 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 147 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 148 | Supplying of following A.C. Ceiling fan BLDC complete with all accessories like down rod, canopy etc. of following sweeps as approved by the Deptt.)as required complete and as directed by the Department [Without regulator].Havells Efficincia Neo 5 STAR model 1200 mm Sweep |
| 149 | Exhaust FanSupplying of following AC Exhaust fan Metallic of following sweeps as approved by the Deptt.as required complete and as directed by the Department [Without regulator].Ventil Air DB NEO/DB 300mm Sweep |
| 150 | EARTHING AND LIGHTNING PROTECTIONEARTH PITEarthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 151 | Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 152 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 153 | Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. |
| 154 | LT POWER & CONTROL CABLESSupplying one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size (cable rate as per RR cable price list 2023)3.5 C 300 sqmm Aluminium armoured |
| 155 | Supplying one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size (cable rate as per RR cable price list 2023)3.5 C 150 sqmm Aluminium armoured |
| 156 | Supplying one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size (cable rate as per RR cable price list 2023)3.5 C 50 sqmm Aluminium armoured |
| 157 | Supplying one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size (cable rate as per RR cable price list 2023)3 C 2.5 sq mm copper armoured |
| 158 | Supplying one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size (cable rate as per RR cable price list 2023)1 C 16 sqmm Aluminium unarmoured |
| 159 | CABLE LAYINGLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering.Upto 35 sq. Mm |
| 160 | Above 35 sq. mm and upto 95 sq. mm |
| 161 | Above 95 sq. mm and upto 185 sq. mm |
| 162 | Above 185 sq. mm and upto 400 sq. mm |
| 163 | CABLE TERMINATIONSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 300 sq. mm (70mm) |
| 164 | 3½ X 150 sq. mm (50mm) |
| 165 | 3½ X 50 sq. mm (35mm) |
| 166 | 4 X 16 sq. mm (28mm) |
| 167 | HIGH MASTSupplying and Installation of ACEON 30 meters High Mast Lighting Tower for large area with LED Flood Lighting System with 12 LED FLOOD LIGHT LUMINAIRES 350 W as directed by the dept. |
| 168 | CABLE ROUTE MARKERSupplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 169 | Hume PipeProviding, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required.150 mm dia |
| 170 | GI PIPESProviding, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required100 mm dia |
| 171 | 50 mm dia |
| 172 | Supplying and Installation LIFESECURE CO2 Based Wheeled FireExtinguisher 9 kilogram kg |
| 173 | Supplying and Installation of insulating mat for electrical purpose 1m x7m blue category III ISI marked Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail