| 1 | Providing and fixing Golden Champ chawkhats (kiln seasoned) including cost of straps iron holds fast hinges, screws, nails, fevicol etc. and painting two coats of wood preserver to sides of chawkhats. Rate includes the cost of dismantling of all damages chawkhats and making and good the damaged to walls plaster and floors as required including disposal of rubbish to the dumping ground the rate further includes the cost of painting two coats syn, paint over one coat of wood primer complete in all respect and to the entire satisfaction of Engineer-in-charge. (Size: 4 ½”x 2 ¼ ” ) NS |
| 2 | Providing and laying vitrified floor tiles ( Single Charge) in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm NS |
| 3 | Dismantling of ceramic tiles carefully and scraping the plaster to making the surface clean for refixng the glazed tiles removing of malba complete in all respect and to the entire satisfaction of the Engineer in Charge. NS |
| 4 | Providing water treatment by laying one coat to cement adhesive ( Tape Crete) mixed with mixed cement in the ratio 1:3 ( one part of adhesive and three part of cement complete in all respect to entire satisfaction Engineer in charge NS |
| 5 | Providing and fixing 35mm thick ISI marked flush door shutters with iron butt hinges (heavy weight)125x40x4mm and screws, conforming to IS: 2202 (Part I) non-decorative type, core of block board. The rate further rate includes the cost of aluminium fittings such as one no. 250x16mm sliding bolt, one no. 200x10mm and one no. 150x10mm tower bolt, two nos. 125mm size D-type handles and painting the shutter with two coats of special quality paint over one coat of primer including preparation of plywood surface for painting complete in all respects and to the entire satisfaction of Engineer-in-charges. NS |
| 6 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: DSR 13.47 |
| 7 | New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ .90 kg/10 sqm) DSR 13.47.1 |
| 8 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. DSR 12.41 |
| 9 | 110 mm diameter DSR 12.41.2 |
| 10 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. DSR 10.25 |
| 11 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works DSR 10.25.2 |
| 12 | Providing & fixing glass panes with putty and glazing clips in steel doors,windows, clerestory windows, all complete with : DSR 10.30 |
| 13 | 4.0 mm thick glass panes DSR 10.30.1 |
| 14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. DSR 8.31 |
| 15 | 12 mm cement plaster of mix : DSR 13.4 |
| 16 | 1:6 (1 cement: 6 coarse sand) DSR 13.4.2 |
| 17 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead DSR 15.56 |
| 18 | Regrading terracing of mud phaska covered with tiles or brick, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement : 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded), all complete as per directions of Engineer-In-Charge DSR 14.13 |
| 19 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase DSR 12.21.1 |
| 20 | Supply of 1st quality brick tiles 9\\"x 4 1/2\\"x 1 1/2\\" complete in all respect and to the entire satisfaction of Engineer-in-Charge. NS |
| 21 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DSR 15.60 |
| 22 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: DSR 6.1 |
| 23 | Cement mortar 1:6 (1 cement : 6 coarse sand) DSR 6.1.2 |
| 24 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. DSR 15.7 |
| 25 | In cement mortar DSR 15.7.4 |
| 26 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. DSR 15.2 |
| 27 | Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) DSR 15.2.2 |
| 28 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. DSR 11.3 |
| 29 | 40 mm thick with 20 mm nominal size stone aggregate DSR 11.3.1 |
| 30 | Distempering with 1st quality acrylic distemper, (ready mixed )having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour DSR 13.81 |
| 31 | old work (one or more coats) DSR 13.81.1 |
| 32 | Providing and applying white cement based putty of average thickness 0.50 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. NS |
| 33 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. DSR 13.91 |
| 34 | Finishing walls with Acrylic Smooth exterior paint of required shade : DSR 13.111 |
| 35 | Old work (One or more coat applied @ 0.90 ltr/10 sqm). DSR 13.111.2 |
| 36 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge. DSR 16.83 |
| 37 | Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin- charge. (Old CC paver blocks shall be supplied by the department free of cost). DSR 16.84 |
| 38 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing DSR 11.26 |
| 39 | 25 mm thick DSR 11.26.1 |
| 40 | Rubbing and polishing on existing marble work/Granite work/stone work where ever required to give high gloss finish complete in all respect to the entire satisfaction of Engineer in charge. NS |
| 41 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners ofrequired dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P.brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : DSR 21.1 |
| 42 | For fixed portion DSR 21.1.1 |
| 43 | Anodised aluminium (anodised transparent or dyed to required shade according toIS: 1868, Minimum anodic coating of grade AC 15) DSR 21.1.1.1 |
| 44 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) DSR 21.1.2 |
| 45 | Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) DSR 21.1.2.1 |
| 46 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. DSR 21.4 |
| 47 | With stainless steel cover plate minimum 1.25 mm thickness DSR 21.4.1 |
| 48 | Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineerin-charge. DSR 21.2 |
| 49 | Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side DSR 21.2.1 |
| 50 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paidin basic item): DSR 21.3 |
| 51 | With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) DSR 21.3.2 |
| 52 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. DSR 21.8 |
| 53 | Upto 5mm depth and 5 mm width DSR 21.8.1 |
| 54 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. DSR 9.84 Please Enable Macros to View BoQ information |