| 1 | SCHEDULE `A' PART - I (Building Works) is not prepriced by MES and prepriced rates indicates 0.00 under column 5 signifies this fact only. |
| 2 | Construction of Married Accn triple Storey (G+2) of 28 quarters including parking with permanent specifications complete all as specified and as shown on drawings. (Pocket A6) |
| 3 | Construction of Married Accn triple Storey (G+2) of 28 quarters including parking with permanent specifications complete all as specified and as shown on drawings. (Pocket Z) |
| 4 | Construction of Married Accn triple Storey (G+2) of 22 quarters including parking with permanent specifications complete all as specified and as shown on drawings. (Pocket A) |
| 5 | Construction of Married Accn triple Storey (G+2) of 52 quarters including parking with permanent specifications complete all as specified and as shown on drawings. (Pocket G) |
| 6 | NOTE: Schedule ‘A’ Part II to XIII under Ser No 2.01 to 2.12 are Prepriced by MES. |
| 7 | Lump sum price worked out by the Contractor for “ SITE CLEARANCE, EXCAVATION AND EARTH WORK ” as listed in Schedule ‘A’ Part II |
| 8 | Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION WORKS) ” as listed in Schedule ‘A’ Part III |
| 9 | Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part IV |
| 10 | Lump sum price worked out by the Contractor for “SEWAGE WORKS” as listed in Schedule ‘A’ Part -V |
| 11 | Lump sum price worked out by the Contractor for “PATH WORKS” as listed in Schedule ‘A’ Part- VI |
| 12 | Lump sum price worked out by the Contractor for \\"FENCING, GATE AND COMPOUND WALL WORKS” as listed in Schedule ‘A’ Part- VII |
| 13 | Lump sum price worked out by the Contractor for \\"AREA DRAINAGE WORKS” as listed in Schedule ‘A’ Part VIII |
| 14 | Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING\\" as listed in Schedule ‘A’ Part IX |
| 15 | Lump sum price worked out by the Contractor for “HOT WATER SUPPLY WORKS\\" as listed in Schedule ‘A’ Part X |
| 16 | Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION WORKS\\" as listed in Schedule ‘A’ Part XI |
| 17 | Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY WORKS ” as listed in Schedule ‘A’ Part XII |
| 18 | Lump sum price worked out by the Contractor for “DEMOLITION AND DISMANTLING WORKS\\" as listed in Schedule ‘A’ Part XIII |
| 19 | SCHEDULE `A' PART - XIV MISC ITEMS (B/R & E/M, Srl Item No. 3.01 to 14.01 is not prepriced by MES and prepriced rates indicate 0.00 under column 5 signifies this fact only. |
| 20 | INTERNAL ELECTRIFICATION WORKS |
| 21 | Supply and fixing of Metal flush box 8 module complete all as specified and directed by Engr-in-Charge. |
| 22 | Supply and fixing of modular blanking plate on the modular plate complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and fixing of LED building security light fitting 25 Watt 230 V AC outdoor type with high-pressure die-cast aluminum housing and heat-resistant complete with driver, lamp bracket with impact and corrosion-resistant, including thermal management in multiple optics, complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge. |
| 24 | Supply and fixing of TV coaxial connector type F-1 modular designed for cable installation of white colour combines functionally with a sleek design complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and fixing of wall mounted fittings with ABS housing and clear polycarbonate cover, including retrofit LED bulb 7/9 watts and provision of flexible 3 core copper cable 0.5 Sqmm from connector/ ceiling rose to fittings conforming to City-1/ City-2 complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and fixing of LED light fitting 1 x 9 W/ 1 x 10 Wbulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-Charge. |
| 27 | INTERNAL WATER SUPPLY WORKS |
| 28 | Supply and fixing of Brass CP central hole wash basin mixer with 450 mm braided connection pipe (without pop-up) for mixing hot & cold water for 15 mm bore iron pipe and fixed as in repair complete all as specified and directed by Engr-in-Charge. |
| 29 | Supply and fixing of Wall mixer with L bend (Provision for over head shower), cast copper alloy, chromium plated for mixing hot & cold water, screwed down for 15 mm bore iron pipe complete all as specified and directed by Engr-in-Charge. |
| 30 | Supply and fixing of Brass CP Wall mixer swan neck for mixing hot & cold water, screwed down for 15 mm bore iron pipe and fixed as in repair complete all as specified and directed by Engr-in-Charge. |
| 31 | SEWAGE WORKS |
| 32 | Supply and fixing of SFRC heavy duty manhole cover with frame Size-600x600mm using M-30 grade cement concrete using 20 mm graded stone aggregate including reinforcement 10mm dia for TMT steel with 100mm c/c both ways, manufctured by vibro compaction process, with steel rims to prevent damages of the edges,conforming to IS:12592 complete all as specified and directed by Engr-in-Charge.Note :- 04 Nos Manhole cover pertain to Rain Water Harvesting Works. |
| 33 | PATH WORKS |
| 34 | Material and labour for PCC M-30 (20mm graded aggregate) factory made saucer drain (size-300x600), 60mm thick channel manufactured by vibro compaction process complete all as specified and directed by Engr-in-Charge. |
| 35 | FENCING, GATE AND COMPOUND WALL WORKS |
| 36 | Supply and fixing of 100 mm dia nylon roller (Synthetic polyurethane) as conveyor rollers low friction, chemical resistant, temperature resistent, reduce noise, increase machine servicelife and create a more pleasant work environment etc. complete all specified and directed by Engr-in-Charge. |
| 37 | AREA DRAINAGE WORKS |
| 38 | Supply and fixing of SFRC heavy duty Drain cover with eight holes (Size - 900 x 450 x 90mm) using M30 graded cement concrete reinforcement with 10mm dia for TMT steel with 100mm c/c both ways, manufactured by vibro compaction conforming to IS:12592 complete all specified and directed by Engr-in-Charge. |
| 39 | RAIN WATER HARVESTING WORKS |
| 40 | Trial bore of 280 mm dia upto 60 meter depth below ground level in any kind of soil strata including hard standing stone/boulder including electric logging, PVC cap etc complete all specified and directed by Engr-in-Charge. |
| 41 | Supply and laying of 200 mm PVC perforated pipe including nylon screen 6-8mm thick for perforted pipe etc complete all specified and directed by Engr-in-Charge. |
| 42 | Supply and fixing of SFRC heavy duty manhole cover with frame Size - 450 x 600mm using M-30 grade cement concrete including reinforcement 10mm dia for TMT steel with 100mm c/c both ways, manufctured by vibro compaction process, with steel rims to prevent damages of the edges,conforming to IS:12592 complete all as specified and directed by Engr-in-Charge. |
| 43 | HOT WATER SUPPLY WORKS |
| 44 | Disconnecting and taking down existing geyser of any type and capacity, keeping in the safe custody for refixing complete all specified and directed by Engr-in-Charge. |
| 45 | Refixing only geysers of any type and capacity (item obtained from Srl Item No.10.01) complete including anchor fastener of suitable size, inlet/ outlet PVC connection, electrical connection etc. complete all specified and directed by Engr-in-Charge. |
| 46 | EXTERNAL ELECTRIFICATION WORKS |
| 47 | Disconnecting and taking down existing service wire of any size from existing locations complete all as specified and directed by Engr-in-Charge. |
| 48 | Disconnecting and taking down existing electric meter of any type and size from existing locations and depositing the same in the MES store complete all as specified and directed by Engr-in-Charge. |
| 49 | Supply and fixing of AC single phase static meter of accuracy class 1.0, 240 V, 50 Hz with LCD display of rating 5-30 A (Measure and displays KWH, V, Current 1 KW PF last month history of KWH, MD in KW with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all as specified and directed by Engr-in-Charge. |
| 50 | EXTERNAL WATER SUPPLY WORKS |
| 51 | Taking down of water meter (cold water flow type) 15mm dia, including coupling and all necessary fittings/ accessories (including cutting existing steel tubing for alteration or fixing water meter and screwing steel tubing upto 40 mm bore) complete all as specified and directed by Engr-in-Charge.Note :- Old unserviceable water meter shall be deposited in MES Store Yard. |
| 52 | Supply and fixing of water meter (cold water flow type) 15mm dia, ISI marked, class B screw end including coupling and all necessary fittings/ accessories (including cutting existing steel tubing for alteration or fixing water meter and screwing steel tubing upto 40 mm bore complete all as specified and directed by Engr-in-Charge. |
| 53 | Fixing only water meter (cold water flow type) 15mm dia, including coupling and all necessary fittings/ accessories (including cutting existing steel tubing for alteration or fixing water meter and screwing steel tubing upto 40 mm bore complete all as specified and directed by Engr-in-Charge. |
| 54 | Material and labour for water meter box of size 450 x 300 x 150 mm made of 3 mm thick MS sheet cover fixed with angle iron frame with locking arrangement and lifting handle including two coats of anti corrosive black bituminous paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.Note :- The rate quoted by bidder for Water Meter and connecting items shall be inclusive in lump sum Building Works) |
| 55 | DEMOLITION AND DISMANTLING WORKS |
| 56 | Taking down Bib tap 15mm dia any type from site complete all specified and directed by Engr-in-Charge. |
| 57 | Taking down stop cock/angle cock/valves 15mm dia any type from site complete all specified and directed by Engr-in-Charge. |
| 58 | Taking down PVC flushing cistern 10 ltr capacity along with flushing pipe including brackets complete all specified and directed by Engr-in-Charge. |
| 59 | SOLAR POWER PLANT WORKS |
| 60 | Design, supply, installation, testing and commissioning of roof top solar power plant with provision of net virtual metering having capacity 1 KW complete in all respect as per guidelines of Senior Town Planner of UT Chandigarh complete all as specified and directed. |
| 61 | Note :- Schedule of credit Rs. 5200538.00 will be deducted from total quoted amount while calculating contract sum. Please Enable Macros to View BoQ information |