| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | Taking down cement or cement lime plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc.complete all as specified and directed. |
| 3 | Supplying & applying for two component elastomeric acrylic polymer modified cementitious waterproofing coating on Brick level, SmartCare Damp Block 2K or approved equivalent, having 100% elongation as per ASTM D412, resisting 5 bars hydrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per ASTMC1202, crack bridging up to 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI, will be apply on both Positive & Negative side and resist up to 5 Bars of Hydrostatic Pressure. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc. After coating will sprinkle Sand on the coating, complete as manufacturer specifications or all as specified and directed. Note - Taking down plaster and rendering will be measured and paid seprately. |
| 4 | M&L for 15mm thick cement pastering in cement mortar 1:4 and mixing the water proofing compound as per manufactures instructions on brick or concrete surface of wall finished complete all as specified and directedNote : Water proofing compound shall be measured and paid saparately under item . |
| 5 | M&L for 10mm thick cement plastering in cement mortar CM 1:6 finishing the surface complete all as specified and directed. |
| 6 | M&L prepration of new plastered or unplastered surface of walls and applying two coats of distemper oil emulsion over complete all as specified and directed. |
| 7 | Material and Labour for exterior painting work including complete removal of existing loose paint layers till plaster level by using jet pressure washer and crack filling up to 3mm by using crack seal & up to 10mm by using textured crack filler. Touch-up by using wall putty with silicon additives followed by application of one coat of truecare exterior primer on walls and Chajjas and applying two coats of modified acrylic smooth emulsion exterior grade with silicon having anti-algal and Dust pickup resistance properties, Material should be applied (Dilution, Recoating period etc..) as per manufacturer instructions by using fully automatic air less spray machine having flow speed of minimum 1ltr per minute and pressure of 3300 PSI complete all as specified and directed.Note-The above Specification is guaranteed for 4 year performence warranty |
| 8 | Complete removal of existing treatment of any type/ description such as distempering work ,internal emulsion etc from internal/external surfaces of walls & ceiling with mechanical means/grinder including removal of material from site complete all as specified and directed. |
| 9 | Supply only integral water proofing compound ISI marked complete all as specified and directed. |
| 10 | Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed. |
| 11 | All as per srl item No 10 hereinbefore but n. exc 1.5 sqm each complete all as specified and directed. |
| 12 | S&F Powder coated Pressed steel frames made of MS sheet of 1.25 mm thickness for doors with double rebate including necessary fixing lugs hinges, lock strike plate, hold fasts , PCC 1:2:4 B1 hold fast blocks etc., complete as specified,size 125x 60mm including cutting holes and making good reqd to shape for hold fast blocks for new frame complete all as specified and directed. Note :- Disturbed portion of existing floor /wall / tile / plaster etc duing fixing of chowkhats shall be repaired to match with existing finish .Cost of the same will be included in this item. |
| 13 | M&L Plain cement concrete (1:3:6) type C-0, using 12.5 mm graded mechanically crushed stone aggregate as in back filling of pressed steel frame /hold fast blocks etc and similar complete all as specified and directed. |
| 14 | S&F 30 mm thick Flush shutters, solid core construction, with out block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 15 | S&F 35mm Glazed and skeleton shutters, 2nd class hard wood open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 16 | M&L for preparing of new surface of wood and wood based material of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel pain and one coat of pink primer complete all as specified and directed. |
| 17 | S&F Mild steel barrel tower bolt 200mm long stove enamelled black with bright bolt and fixed complete all as specified and directed. |
| 18 | S&F Mild steel sliding door bolt of size 250mm , stove enamelled black with bright bolt not less than 12 mm dia, with and including a minimum of 6 bolts and nuts, complete all as specified and directed. |
| 19 | S&F MS pressed handles of size 125mm oval type stove enamelled black complete all as specified and directed. |
| 20 | S&F in repair 300 mm long MS rat tail pattern spring hinge including roller and roller plate, complete all as specified and directed. |
| 21 | S&F factory made steel windows box type using ERW hollow 'P' section comprising double frame for glaged and gauged skelton shutters jointed interally with flat iron 40x4mm complete including grill of 8mm square bar, fixed horrizontally @ 10cm centre to centre, hinges,handle tower bolts,lugs etc all as shown on drawing noTD-219(c) sheet 1/3 to 3/3 and TD-220 (c) sheet 1/3 to 3/3 as applicable complete all as specified and directed. Note;- (i) for the purpose of measurement & payment double shutter with frame shall be considered as one unit. (ii) Wire mesh and glass, measured and paid for separately |
| 22 | S&F sheet glass ordinary quality 4 mm thick and glazing with oil puttly or wooden beads in square not exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 23 | S&F in repair Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directied |
| 24 | M&L for preparing surfaces of any description over 10 cm girth or width, not otherwise described and applying two coats of synthetic enamel paint over a coat of Red oxide on new surfaces of steel or iron, complete all as specified and directed. |
| 25 | Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level), complete all as specified and directed. |
| 26 | M&L for Ceramic floor tiles of 7 to 8mm thick of size 600 X 600 mm in floor etc set and jointed in neat cement lurry and pointed in white cement to match over and including 15mm thick screed bed in CM (1:4) laid in complete all as specified and directed. |
| 27 | M&L fo 25mm thick PCC (1:2:4) type B-0 using 12.50 mm graded crushed stone aggregates in complete all as specified and directed.as in floor base complete all as specified and as directed. |
| 28 | Demolition of brick work built in cement mortar complete all as specified and directed. |
| 29 | M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in in cm 1:6 with sub class ‘B’ bricks straight or curved on plan exc 6m mean radius complete all as Specified and directed |
| 30 | Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 31 | S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed to self tapping screws complete all as specified and directed. |
| 32 | S&F pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 mpa as in ridges, roof covering/clading to wall, fixed with self tapping screws complete all as specified and directed. |
| 33 | S&F MS hollow rectangular/square/circular tubes/pipes of Fe410-W(Gde-E-250) Grade as in frame work for roof/rafter/purline/chajja/trusses/columns/struts etc and like similar items etc. complete all as specified and directed. |
| 34 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed. |
| 35 | M&L for Hard core of broken stone boulders of gauge 40 mm spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface complete all as directed and specified |
| 36 | M&L for PCC (1:3:6) C-2, 50mm thick as in PCC path/ plinth protection.finished the surfaces even and smooth with out using extra cement complete all as specified and directed. |
| 37 | S&F Curtain rod Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers complete all as specified and directed. |
| 38 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/ slabs/ blankets, any thickness, including cover fillets complete all as specified and directed. |
| 39 | M&L anodised aluminium snap grid false ceiling of grid size 605x605mm consisting of aluminium main and \\"T' sections of size 25x35x1.5mm thick and wall angles of size 25x 25x 1.5 mm thick suspended with GI wire suspenders of 6mm dia of suitable length and 8-10 mm thick gypsum board, 60x60 cm size fixed with staples on snap grid complete all as specified and directed. |
| 40 | S&F for Solid PVC wall Lining (Fluted)Consisting of 5mm thick colour PVC sheet in Strips & Channel feathered at the edge of fixing on solid PVC wall lining and solid PVC pertition inclusive of solvent cement and fixing at site but single side prelam PVC sheet used insted of plain colour sheet complete all as specified and directed. |
| 41 | M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed |
| 42 | M&L for 75mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in sub base of flooring complete all as specified and directed. |
| 43 | M&L for Machine cut Kota stone slab flooring 20mm (+2mm) thick laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 44 | All as per item No 43 here in before on vertical surfaces as in skirting/dado of size as required at site complete all as specified and directed. |
| 45 | M&L preparation of new plastered or unplastered surfaces of walls, two coats of cement base paint complete all as specified and directed. |
| 46 | Supply and fix Steel rolling shutters, ( Thickness of laths 1.25 mm ) with ball bearing, as specified including top cover, an choring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete:gear operated type with bevel gear box and crank handle complete incl dismantelling of old shutter complete all as specified and directed |
| 47 | S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed. |
| 48 | Dismantling of asbestos cement sheets [corrugated, semi-corrugated, etc] in roof coverings complete all as specified and directed. |
| 49 | M&L for providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 50 | Material and labour for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed in cement mortar 1:3 including making joints with or without grooves (thickness ofjoint except at sharp curves shall not be more than 5mm) including making drainage opening where ever required complete all as specified and directed. |
| 51 | Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc complete all as specified and as directed. |
| 52 | M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessity cutting chasing where ever required shall be part of job & making good the disturbed surfaces shall be part of job. |
| 53 | All as per item No 52 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed. |
| 54 | All as per item No 52 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed. |
| 55 | All as per serial item No 52 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 2.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed. |
| 56 | Supply & fixing in replacement of Modular switch 1 way 6A, 1 module type complete all as specified and directed. |
| 57 | Supply & fixing in replacement of Modular switch 1 way 16A, 1 module type complete all as specified and directed. |
| 58 | Supply & fixing in replacement of Modular Socket, 6A - 5 pin 2 module type complete all as specified and directed. |
| 59 | Supply & fixing in replacement of Modular Socket 6A/16A - 2/3 pin 2 module type complete all as specified and directed. |
| 60 | Supply and Fixing in replacement of LED light fittings 1 x 20 Watt, 220 V, AC decorative box type with driver, holder including LED tubelight connecting up with three core flexible copper conductor cable of size from ceiling rose complete all as specified and directed. |
| 61 | Supply & fixing in replacement of modular ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed. |
| 62 | M & L for Fan step regulator, 120W - 1 module complete all as specified and directed. |
| 63 | S & F in replacement of Energy saving ceiling fans complete with blades, down rod and with all accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM five star rated with brushless direct current motor (BLDC) with remote control including cost of GI Pipe suitable hanging the fitting upto 3 mtr down from truss structure complete all as specified and directed.Note:-Unsv C/Fan will be deposted to MES office. |
| 64 | Supply & fixing in replacement of lamp holder modular type, PVC/ polycarbonate type with back plate suitable for 7 to 18 watts complete all as specified and directed. |
| 65 | Supply & fix in replacement LED inverter Bulb, Cool Day Light, Energy Efficient, Glare Free Soft Light, Power Backup Feature, inbuilt Overcharging Protection, inverter Bulb 15 Watt (CDL) cool day light type of Model 15WLEDB22D of make Havells or equivalant as approved by GE complete all as specified and directed. |
| 66 | S&F in replacement of SPN DB suitable for MCBs of single pole and neutral 12 Way as per IS - 8623, IP-54 protection,double door type with 200 amp rated bus bar complete all as specified and directed.Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. (ii) Dismantling of existing sheet metal box will be deposited to MES. (iii) Masonry work to fill the space of iron sheet box will be part of the job. (iv) Energy Meter will be refixed & connected after fixing of new DB. (v) MCB'S shall be fixed with copper wires FRLS 1.5/2.5 Sqmm incl appropriate size of brass/Cooper thimbles. Note :- Existing metal enclosure of SPN DB will be deposited to MES. |
| 67 | M&L in replacement for Sub main wiring with 2 runs of single core FRLSH PVC insulated unsheathed multistranded copper conductor cable of size 2x4 sqmm ( line conductor) & 1x4 sqmm ( earth conductor), 1100 volt grade drawing in & including heavy duty non metallic PVC conduit , ISI marked, incl accessories not less than 25 mm in dia & concealed in wall, roof etc including PVC insulated, FRLSH unsheathed single core multistranded copper conductor cable, green in colour as earth conductor including cutting charges for concealed conduit wiring etc and making good cutting not exceeding 10 cm grith complete all as specified and directed.Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size (iii) Two runs of copper conductor cable and one run of copper earth wire including PVC conduit will be measured and paid as one unit only. |
| 68 | Supply and fix in replacement of MCB SP up to 6-32 Amp ('B' Curve) complete all as specified and directed. |
| 69 | Supply and fix in replacement of MCB SPN upto 40 -63 Amp ('B' Curve) complete all as specified and directed. |
| 70 | M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frame 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I complete all as specified and directed. |
| 71 | S&F in replacement of new generation energy saving and environmental friendly long life LED building security light 1x25/35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07, with all accessories including suitable bracket with suitable dia light grade GI pipe bend to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed. |
| 72 | S&F in replacement of existing unserviceable Plug & Socket Box (sheet metal) with PVC Plug, SPN 20 Amps for Acs complete all as specified and directed.Note : (i) Including cost of masonary work involved and the disturbed surface shall be repaired/match with existing shall be part of job. |
| 73 | Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16Sqmm, 2.0 core laid in trenches /on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. |
| 74 | Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth and getting out in any type of soil complete all as apecified and directed. |
| 75 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and directed.Note : Only punned sand shall be measured. |
| 76 | Returning filling in including, spreading,levelling,watering and well ramming in layers not exc 25cm thick each complete all as specified and directed. |
| 77 | Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed. |
| 78 | Supply and laying GI tube 40 mm light grade as in cable protection pipe including all fittings & taking down / taking out from trench complete all as specified and directed. |
| 79 | M&L for laying of well burnt Brick 23 cm x11.5 cm x7.5 cm for cable protection complete all as specified and directed. |
| 80 | Supply & fixing in replacement of LED light fitting 1x9W/1X10W bulkhead luminaires 230 Volts including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 81 | Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp incl fitting and fixture complete all as specified and directed. |
| 82 | S&F Metal body Turboforce air circulator wall fan energy saving 5 star rating 600 mm sweep energy efficient Model FHACWSTGRY24 of make Havells or equivalent as approved by GE as per latest specifications having 230 Volts incl anchoring arrangement complete all as specified and directed. |
| 83 | Supply and fixing in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm, 2 Core laid in trenches /on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed. Please Enable Macros to View BoQ information |