| 1 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 4 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 5 | Labour for site clearance and cleaning old wall, surface roof etc, all complete job Unskilled labor (BCD P No. 47) |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4(1 Cement: 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 7 | Providing and laying double charged Vitrified floor tiles in different sizes (thickness to be specificed by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622/ISO 13006 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigments etc. complete size of tiel 600X600mm |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for Weather shade, Chajjas, corbels etc., including edges |
| 9 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases, above plinth level upto floor five level, excluding the cost of cenetering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal size) |
| 10 | Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and structs etc. above plinth level upto floor five level, excluding cost of centering, shuttering, finishing and reinforcement: 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III) : 3 graded stone aggregate 20mm nominal size) |
| 11 | 52mm thick cement concrete flooring with concrete hardener topping under layer 40mm thick cement concrete 1:2:4) 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 ltrs per 50 kg. of cement or as per manufactuers specification This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete |
| 12 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grde made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand, filling the joints with coarse sand etc. all complete as per the durection of Engineer-in-charge. |
| 13 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 14 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 15 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 16 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 17 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 18 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 19 | Providing & fixing pressed steel door frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges ,jamb, lock jamb, bead and if requiredangle threshold of mild steel angle section 50 X 25mm, orangle threshold of mild steel angle section 50 X 25mm, orbase ties of 1.25mm pressed mild steel welded or rigidlyfixed together by mechanical means, adjustable lugs withsplit end tail to each jamb including steel butt hinges split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and 2.5mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by the Engineer Incharge - Profile - B - Fixing with adjustable lugs with split end tail to each jamb |
| 20 | Supplying and fixing rolling shutters of approved makemade of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guidesand arnagements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.50cm long wire sprinings manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-Part 1 and M.S. top cover ofrequired thickness for rolling shutters - 80X1.25mm M.S. laths with 1.25mm thick top cover |
| 21 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285 fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc.. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling C.P. brass / stainless steel screws, all complete as per architetural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) |
| 22 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required inlcluding the cost of EPDM rubber/neoprene gasket required (fittings shall be paid for separately) --- Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 23 | Providing and fixing glazing in aluminium door, window, ventilator, shutters and partitions etc, with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (cost of aluminium snap beading shall be paid in basic item) With float glass panes of 4mm thickness (weight not less than 10kg/sqm.) |
| 24 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 25 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2 mm at 100mm. centres and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40x40x6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangements, stoppers, handles, including applying a priming coat of red lead paint, carriage , hoisting and taxes all complete as per building specification and direction of E/l. |
| 26 | Water proofing for old and new roof slab - Providing and laying water proofing treatment on roof slab by applying two component, factory designed, ready to use acrylic modified flexible material applied with brush roller or spray for water proofing coating as per manufacturer specifications with gollowing steps: |
| 27 | a. Surface preparation - Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all matrials, labour, tools, complete, ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage. On identification of seepage cement grouting to be done with non shrink expanding adminxture of Sika India Pvt Ltd./MYK schomberg/Dr. Fixit/Fosroc or equivalent. Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc. sahll be chamfered with 150mm X 150mm fillet of mortar (cement, sand 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK scholmberg/Dr fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer, Repairing surface irregularities, damaged concretein base slab dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 28 | b. 1st coat -Apply 1st coat of two component acrylic modified, ready to use flexible cementitious material on surface saturated dry roof and inside wall of parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @ 1.50kg/sqmt/coat. Fore the prupose of measurement the entire treated surface will be measured. |
| 29 | c. 2nd coat - To apply the 2nd coat of two component acrylic modified, ready to use flexible cementitious material on right angle to the 1st coat over the glass fibre laid surface 2nd coat should be applied @ 0.7kg/sqmt/coat. For the purpose of measurement the entire treaed surface will be measured After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The water proof coating to be protected from damage before screed over it. Water proofing brand Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fioxit Pidiffin 2K/MYK Aquafin TG. Product performance- Chemical base part A Acrylic copolymer, Part B Specially graded cementitious powdere density 1.6 kg/I (mixed density) at +27 degree C. Tensile strength - 2N/mm2 after 28 days (with fibre cloth) (according to ASTM D 2370) Pullout bond strength - 2 N/mm2 (concrete failure) (According to ISO 4624) slant-shear bond strength - 4N/mm2 (according to FIP 5.15) Elongation at break - 35% without fibre cloth and 20% with fire cloth (according to ASTM D 2370) |
| 30 | d. Protection of treated surfaces with PCC ; The treated syrface shound be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt X 2 mtr. Keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete (Paid separately for this items) All corners shall be chamfered with 150mm X 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - peripherial gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete nd the peripherial mouth to be sealed with mosture insensitive epoxy putty of sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/Fosroc. For purpose of measurement the entire treated surfaces will be measured e, Grooves of PCC surface should be filled with polysulphide sealant. Brand - Sika India Pvt. Ltd. /MYK Schomberg/Dr. Fixit/Foscroc warranty for five years. |
| 31 | Covering of treated surface with PCC - Providing 25mm thick Cement Concrete M-20 (1:1.5:3) maintaining slope in alternte 2 mt X 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with adminxture of integral water proofing and placing in position striking curing, taxes and royalty all complete as per building specificastion and direction of E/I. Panels that has been left should be casted next day. There should be 6mm gap between panels brand - Sika-Plastocrate plus, MYK proof WP 10, Fosroc - Conplast X 421ic, Dr. Fixit pidiproof LW+ |
| 32 | Providing and filling 6mm thick groove between 25mm PCC panels with polysulphide sealant (Poring Grade) as per drawings and technical specifications and direction of E/C (with 18%GST) brand - Sika-Polysulphide, Fosroc-Thioflex 600, Dr. Fixit Piddiseal PS (42P) MYK seal PS or equvalent |
| 33 | Carriage of materials |
| 34 | Cement |
| 35 | Coarse Sand |
| 36 | Stone Chips |
| 37 | ELECTRIFICATION WORK |
| 38 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 39 | Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 40 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 41 | 2x10 Sqmm + 1x10 sq mm earth wire |
| 42 | S/F Ceiling Rose: Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 43 | S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required. |
| 44 | Providing and fixing following TP & N disconnector fuse switch unit inside the existing panel boards with ISI maerked HRC fuses including drilling holes in cubicle panel, making connections etc. reqired 63 amps double pole |
| 45 | Supplying and fixing following metal boxe of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover infront including painting etc. as required. |
| 46 | 121mm X 173mm X 48mm |
| 47 | 170mm X 221mm X 48mm |
| 48 | 2101mm X 206mm X 48mm |
| 49 | Supply, installation, testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR. PVC insulated copper wire suitable for 230V, 50Hz, single phase supply etc. complete as required. - 1400mm (56\\") BLDC star rating 32W ceiling fan |
| 50 | 15\\" metal exhaust fan |
| 51 | 16\\" (400mm) wall mount fan |
| 52 | SITC of following rating LED flood lighting luminare with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for suply voltage 100-270VAC 50HZ luminare |
| 53 | Supply and fixing following ways singles pole and neutral sheet steel MCB DB 240V on surface/recess complete with tinned copper bush bar neutral bus bar reeth bar, din bar, interconnections, powder paint all completed |
| 54 | 6 amps to 32 amps rating SPN MCB C series 10KA breaking capacity |
| 55 | 200AH tubular lead acid batery with 36 mointh replacement gauranty IS 1652:1991 |
| 56 | Trolly for single tubular battery |
| 57 | 1100-1200 VA sine wave interter input AC range 100-300AV wide 90V-300V AC standard - 180V-260V AC DV range 10.5 to 14.2 |
| 58 | Supplying and fixing of holder type LED 9/10 watt |
| 59 | Add 18% GST |
| 60 | Add 1% Labour Cess Please Enable Macros to View BoQ information |