| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 3 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 4 | Finishing walls with acrylic smooth exterior paint with sillicone additives of requited shade . New work : 2 or more coats applied @1.43 Ltr/10sqm over and including base coat of waterproofing cement paint applied @2.2 Kg/10 sqm |
| 5 | 52mm thick cement concrete flooring with concrete hardener topping under layer 40mm thick cement concrete 1:2:4) 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 ltrs per 50 kg. of cement or as per manufactuers specification This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete |
| 6 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 7 | Providing and laying rectified glazed ceramic floor tiles 300x300mm or more (thickness to be specified by manufacturer) of 1st quality conforming to IS:15622 with approved make in all colours,shades,except white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/sqm. including pointing the joints with white cement and matching pigments, etc.complete. |
| 8 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 9 | Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grde made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of course sand, filling the joints with coarse sand etc. all complete as per the durection of Engineer-in-charge. |
| 10 | Water proofing for old and new roof slab - Providing and laying water proofing treatment on roof slab by applying two component, factory designed, ready to use acrylic modified flexible material applied with brush roller or spray for water proofing coating as per manufacturer specifications with gollowing steps: |
| 11 | a. Surface preparation - Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all matrials, labour, tools, complete, ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage. On identification of seepage cement grouting to be done with non shrink expanding adminxture of Sika India Pvt Ltd./MYK schomberg/Dr. Fixit/Fosroc or equivalent. Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc. sahll be chamfered with 150mm X 150mm fillet of mortar (cement, sand 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK scholmberg/Dr fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer, Repairing surface irregularities, damaged concretein base slab dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 12 | b. 1st coat -Apply 1st coat of two component acrylic modified, ready to use flexible cementitious material on surface saturated dry roof and inside wall of parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @ 1.50kg/sqmt/coat. Fore the prupose of measurement the entire treated surface will be measured. |
| 13 | c. 2nd coat - To apply the 2nd coat of two component acrylic modified, ready to use flexible cementitious material on right angle to the 1st coat over the glass fibre laid surface 2nd coat should be applied @ 0.7kg/sqmt/coat. For the purpose of measurement the entire treaed surface will be measured After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The water proof coating to be protected from damage before screed over it. Water proofing brand Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fioxit Pidiffin 2K/MYK Aquafin TG. Product performance- Chemical base part A Acrylic copolymer, Part B Specially graded cementitious powdere density 1.6 kg/I (mixed density) at +27 degree C. Tensile strength - 2N/mm2 after 28 days (with fibre cloth) (according to ASTM D 2370) Pullout bond strength - 2 N/mm2 (concrete failure) (According to ISO 4624) slant-shear bond strength - 4N/mm2 (according to FIP 5.15) Elongation at break - 35% without fibre cloth and 20% with fire cloth (according to ASTM D 2370) |
| 14 | d. Protection of treated surfaces with PCC ; The treated syrface shound be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt X 2 mtr. Keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete (Paid separately for this items) All corners shall be chamfered with 150mm X 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - peripherial gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete nd the peripherial mouth to be sealed with mosture insensitive epoxy putty of sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/Fosroc. For purpose of measurement the entire treated surfaces will be measured e, Grooves of PCC surface should be filled with polysulphide sealant. Brand - Sika India Pvt. Ltd. /MYK Schomberg/Dr. Fixit/Foscroc warranty for five years. |
| 15 | Covering of treated surface with PCC - Providing 25mm thick Cement Concrete M-20 (1:1.5:3) maintaining slope in alternte 2 mt X 2 mt panels with approved quality of stone chips of 20mm to 6mm size graded and cleaned sand of F.M. 2.5 to 3 including screening, shuttering, and mixing cement concrete in mixer with adminxture of integral water proofing and placing in position striking curing, taxes and royalty all complete as per building specificastion and direction of E/I. Panels that has been left should be casted next day. There should be 6mm gap between panels brand - Sika-Plastocrate plus, MYK proof WP 10, Fosroc - Conplast X 421ic, Dr. Fixit pidiproof LW+ |
| 16 | Providing and filling 6mm thick groove between 25mm PCC panels with polysulphide sealant (Poring Grade) as per drawings and technical specifications and direction of E/C (with 18%GST) brand - Sika-Polysulphide, Fosroc-Thioflex 600, Dr. Fixit Piddiseal PS (42P) MYK seal PS or equvalent |
| 17 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 18 | Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 19 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 20 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete sqm |
| 21 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 22 | Supplying, fitting and fixing choukhat in doors using 6X60X6mm MS angle frame all complete job as per specification and direction of E/I |
| 23 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 24 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 25 | Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 26 | Supplying, fitting and fixing M.S. grill gate with M.S. grill made of 20X6mm M.S. flats or 16mm M.S. square bars fitted on 25X25X6mm M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 27 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. with primer |
| 28 | Providing and applying high quality acrylic modified resin based texture of Dholpur/Red sand stone pattern with anti algae and UV resistance properties to e applied as intermediate finish in desired pattern @ 43.04kg/10sqm to form film of 1-1.5mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plastr surface, followed by top coating with Premium Acrylic Smooth exterior paint with silicone additives of required shade by two or more coats @ 1.43ltr/10sqm. complete as the direction of Engineer-in-charge. |
| 29 | Finishing walls with premium acrylic smooth exterior paint with sillicone additives of requited shade . New work : 2 or more coats applied @1.43 Ltr/10sqm over and including base coat of waterproofing cement paint applied @2.2 Kg/10 sqm |
| 30 | Providing two coats of plastic emulsion paint of approved shade and make over old surface including washing cleaning and preparing the walls scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 31 | Providing two coats of oil bound distemper of approved shade and make over old surface including washing cleaning and papering the walls, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I. |
| 32 | Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 33 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 34 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 35 | Supplying and fixing rolling shutters of approved makemade of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guidesand arnagements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.50cm long wire sprinings manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-Part 1 and M.S. top cover ofrequired thickness for rolling shutters - 80X1.25mm M.S. laths with 1.25mm thick top cover |
| 36 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 37 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 38 | Providing and laying rectified glazed ceramic floor tiles 300x300m or more (thickness to be specified by manufacture) of 1st quality conforming to IS:15622 with approved make in colours white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigments, etc all complete. |
| 39 | Providing labour for site clearance and wall rubbing etc all complete |
| 40 | Dismantling lime terracing upto av. 50mm depth with chisel and hammer including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 41 | Dismantling pucca brick or lime work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 42 | Reinforced cement concrete work in arches, archribs, domes, vaults, shells, folded plate and roofs having slope more than 15° up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 43 | Providing tor steel reinforcement of 8mm. dia. rods as per approved design and drawing with cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position (excluding carriage of bars to work site) all complete as per building specification and direction of E/l. TMT FE 500 ( only valid for Tata (Tiscon), SAIL, JSPL, Electrosteel Steels Ltd. Bokaro, & Vizag (RINL) |
| 44 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm |
| 45 | Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 46 | Providing & fixing on wall face unplasticised - Rigid P.V.C. rain water pipes conforming to IS: 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10mm gap for thermal expansion . Single socketed pipes. 110 mm dia |
| 47 | Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 48 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 49 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I. |
| 50 | Supplying, fitting and fixing 32mm , thick good quality well dressed and well seasoned sal wood battened shutters ledged and braced in doors and windows with oxidised iron fittings such as hinges, sliding door, bolts, tower bolts, handled or rings, hooks and eyes, cleats, sand blocks as per schedule, taxes and royalty all complete as per building specification and direction of E/I. |
| 51 | Providing two coats of painting with ready mixed paint of approved shade and make over old wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 52 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 53 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With \\"A\\" grade white 15X15cm Tiles. |
| 54 | Providing and applying white cement based putty of average thickness 1mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 55 | Carriage of materials |
| 56 | Coarse Sand |
| 57 | Stone Chips |
| 58 | Cement |
| 59 | Bricks |
| 60 | Steel |
| 61 | ELECTRIFICATION WORK |
| 62 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 63 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. |
| 64 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 65 | Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 66 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 67 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 68 | 2x4 Sqmm + 1x4 sq mm earth wire |
| 69 | S/F TP MCB DB:- Supplying and fixing of following way, three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (Without MCB/RCCB/ISOLATOR). (All TP MCB DB shall be as per IS:8623) |
| 70 | 4 Ways (4+12 ways) double door |
| 71 | S/F 'C' series MCB:- Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 72 | 6/32A Single Pole |
| 73 | 6/32A TPN MCB |
| 74 | S/F Ceiling Rose: Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 75 | S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 76 | ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required. |
| 77 | S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required. |
| 78 | S.I.T.C of following rating surface mounted LED tube light fittings suitable for 230V, 50Hz, single phase supply etc. complete as required - 20/22W. LED tube light |
| 79 | Bulk head fitting with 9/10Watt CFL/LED |
| 80 | Supplying, 15/16 Watt LED bulb of approved make |
| 81 | Supplying Exhaust fan of 12\\" (300mm) of aproved make |
| 82 | Supply, installation, testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR. PVC insulated copper wire suitable for 230V, 50Hz, single phase supply etc. complete as required. - 1400mm (56\\") ceiling fan |
| 83 | S.I.T.C. of following rating LED street lighting luminarie die cast housing and toughened glass cover (IP-66 portion) in existing pole/pipe for supply voltage 100-270V. AC, 50Hz. Luminaire shall be confirm to IS:10322 part - 5/section 3 and shall be complete with all necessary accessories as required - 60W LED street light |
| 84 | S.I.T.C. of following rating recess/surface mounted LED round/square shape down light luminaire with pressure die cast housing for single phase supply Voltage. Luminaire shall be confirm to IS:10322 Part -5/section 2 of IEC:62722 with all necessary accessories as required - 15/16W LED round down light - as CL |
| 85 | GI Earth Pipe Electrode: Earthing with G.I. earth pipe 4.5 mtr long , 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcol and salt complete as required. |
| 86 | Supplying and nlaying 25mm X 5mm G.I. strips at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required (jointing shall be done by overlapping and with 2sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 87 | Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connection etc. as required |
| 88 | Provioding and laying 1.1 KV grade aluminium armoured cable as per IS 1554 (Part I) heavy duty all cost complete including cost of brass compression gland, cable jointing and end termination as per specification and direction f E/I. |
| 89 | 3.5 core, 50 sq.mm |
| 90 | Add 18% GST |
| 91 | Add 1% Labour Cess Please Enable Macros to View BoQ information |