| 1 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Dismantling R.C.C. work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 4 | Dismantling lime terracing upto av. 50mm depth with chisel and hammer including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 5 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 6 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete sqm |
| 7 | Taking down old door and window shutters including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 8 | Taking down chaukhats in doors including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 9 | Taking sown chaukhats in windows including stacking serviceable materials within 15M,. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 10 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15 degree landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases, above plinth level upto floor five level, excluding the cost of cenetering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand (zone - III): 3 graded stone aggregate 20mm nominal size) |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form for beam, chajja etc. |
| 12 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) |
| 13 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 14 | Supplying fitting and fixing glass panes including supplying putty. Beads and nails after taking out old and broken glass panes and disposal of debris all complete as per building specification and direction of E/I. 4mm plain |
| 15 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 16 | Supplying, fitting and fixing good quality, well dressed and well seasoned local wood work in chaukhat in doors, windows skylights, fanlights and C/W celetial windows openings, including wedge over all clamps complete including application of two coats of wood preservative of approved quality on the surface butting walls and lintels all completeas per building specification and direction of E/I. |
| 17 | Supplying, fitting and fixing collapsible gate of approved size and make properly fabricated with vertical double channels 20 x 10 x 2mm at 100mm centers and braced with M.S. flat diagonals 20 x 3mm with top and bottom rails of T.iron 40 x 40 x 6mm with 38mm dia steel pulleys complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of red lead paint, car riage, hoisting and taxes all complete as per building specification and direction of E/I. |
| 18 | Providing & fixing pressed steel door frames manufactured from commercial mild steel sheet of 1.25mm thickness including hinges ,jamb, lock jamb, bead and if requiredangle threshold of mild steel angle section 50 X 25mm, orangle threshold of mild steel angle section 50 X 25mm, orbase ties of 1.25mm pressed mild steel welded or rigidlyfixed together by mechanical means, adjustable lugs withsplit end tail to each jamb including steel butt hinges split end tail to each jamb including steel butt hinges 2.5mm thick with mortar guards, lock strike-plate and 2.5mm thick with mortar guards, lock strike-plate andshock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by the Engineer Incharge - Profile - B - Fixing with adjustable lugs with split end tail to each jamb |
| 19 | Supplying, fitting and fixing 35mm thick solid core type non-decorative single leaf flush door shutter in door and windows with black board core blended with high quality phenol formal dehydes synthetic resine both side commercial veneered of standard make with oxidised iron fittings such as hinges, towerbolts, handle, cleat and sand blocks and taxes all complete as per building specification and direction of E/I. |
| 20 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 21 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 22 | Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/l. |
| 23 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 24 | Extra for cleaning the old surface by scrapping the entire old white wash or colour wash including cost of scaffolding all complete as per direction of E/I. |
| 25 | Providing two coats of oil bound distemper of approved shade and make over old surface including washing cleaning and papering the walls, scaffolding, washing of floors and taxes all complete as per building specification and direction of E/I. |
| 26 | Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I. |
| 27 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 28 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm sqm |
| 29 | Providing two coats of snowcem of approved shade and make over old surface including washing cleaning and preparing the walls, scaffolding , curing and taxes all complete as per building specification and direction of E/I. |
| 30 | Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I. |
| 31 | 52mm thick cement concrete flooring with concrete hardener topping under layer 40mm thick cement concrete 1:2:4) 1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6mm nominal size) by volume, hardening compound mixed @ 2 ltrs per 50 kg. of cement or as per manufactuers specification This includes cost of cement slurry but excluding the cost of nosing of steps etc. complete |
| 32 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 33 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4(1 Cement: 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 34 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work upto plinth level - 1:3:6 (1 cement : 3 coarse sand (zone - III): 6 graded stone aggregate 20mm nominal zie) |
| 35 | Providing 25mm thick 2nd class patent stone flooring (1:3:5) with 12mm, to 6mm size graded stone chips and top layer 6mm. Thicks (1:3) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 36 | Providing and laying rectified glazed ceramic floor tiles 300x300mm or more (thickness to be specified by manufacturer) of 1st quality conforming to IS:15622 with approved make in all colours,shades,except white, ivory, grey, fume red, brown laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 Kg/sqm. including pointing the joints with white cement and matching pigments, etc.complete. |
| 37 | Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non-woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and transverse direction at 23°C as 650/ 450N/ 5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane : 3 mm thick |
| 38 | Supplying, fitting and fixing M.S. grill made of 20x6mm M.S. flat as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth , carriage of grill to work site, hoisting as per building specification and direction of E/l. (where materials is not supplied by the deptt.) |
| 39 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 40 | Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification) |
| 41 | Providing two coats of synthetic enamel paint of approved shade and make over new wooden surface including cleaning the surface after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 42 | Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direciton of E/l. |
| 43 | Supplying and fixing rolling shutters of approved makemade of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guidesand arnagements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.50cm long wire sprinings manufactured from high tensile steel wire of adequate strength conforming to IS: 4454-Part 1 and M.S. top cover ofrequired thickness for rolling shutters - 80X1.25mm M.S. laths with 1.25mm thick top cover |
| 44 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 45 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 46 | Providing and applying high quality acrylic modified resin based texture of Dholpur/Red sand stone pattern with anti algae and UV resistance properties to e applied as intermediate finish in desired pattern @ 43.04kg/10sqm to form film of 1-1.5mm thickness after scrapping and properly cleaning the surface to remove loose particles from the plastr surface, followed by top coating with Premium Acrylic Smooth exterior paint with silicone additives of required shade by two or more coats @ 1.43ltr/10sqm. complete as the direction of Engineer-in-charge. |
| 47 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 48 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 49 | Providing designation 75 A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/l. |
| 50 | Taking down C.A. Of G.C.I. Sheet in roofs with ridges including stacking the serviceable materials within 15M. Lead and disposal of unserviceable materials with all leads as per direction of E/I. |
| 51 | Structural steel work in single section fixed with or without connecting plate including cutting hoisting, fixing in position and applying a priming coat of approved steel primer all complete |
| 52 | Providing and fixing precoated glavanised iron profile sheets (size shape and pitch of corrugation as approved by Engineer-in-charge total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 gms per sqm as per IS 277, in 240 mpa steel grade 5-7 microns epoxy primer on excluding the cost of purlins , rafters and trussses and including cutting to size and shape wherever required (detail spacification as per DSR items) |
| 53 | Providing and fixing precaoted glavanised sheet roofing accessoires of total coated … do … 15-18microns using self drilling/self tapping screws complete - Ridges plain (500-600mm) |
| 54 | Water proofing for old and new roof slab - Providing and laying water proofing treatment on roof slab by applying two component, factory designed, ready to use acrylic modified flexible material applied with brush roller or spray for water proofing coating as per manufacturer specifications with gollowing steps: |
| 55 | a. Surface preparation - Providing and cleaning of concrete surface to remove dust, oil, grease including removal of existing loose paint/coating and cement laitance by cleaning with compressed air & water jet including all matrials, labour, tools, complete, ponding test to be done after plugging all outlets and to be checked from soffit to identify seepage leakage. On identification of seepage cement grouting to be done with non shrink expanding adminxture of Sika India Pvt Ltd./MYK schomberg/Dr. Fixit/Fosroc or equivalent. Providing and repairing of all corners and joints such as those between the parapet wall and the roof slab etc. sahll be chamfered with 150mm X 150mm fillet of mortar (cement, sand 1:4) admixed with acrylic polymer of Sika/Fosroc/MYK scholmberg/Dr fixit or equivalent. Before chamfering a prime coat shall be given with the slurry of acrylic polymer, Repairing surface irregularities, damaged concretein base slab dead cracks if any, with an acrylic polymer modified repair mortar including a coat of bonding agent of the same with cement slurry including all material, labour, tools complete. |
| 56 | b. 1st coat -Apply 1st coat of two component acrylic modified, ready to use flexible cementitious material on surface saturated dry roof and inside wall of parapet wall upto 600mm by brush or roller. After 1st coat of application, 45 gsm of fibre glass cloth to lay when the first layer is still green. 1st coat should be applied @ 1.50kg/sqmt/coat. Fore the prupose of measurement the entire treated surface will be measured. |
| 57 | c. 2nd coat - To apply the 2nd coat of two component acrylic modified, ready to use flexible cementitious material on right angle to the 1st coat over the glass fibre laid surface 2nd coat should be applied @ 0.7kg/sqmt/coat. For the purpose of measurement the entire treaed surface will be measured After three days of drying the 2nd coat, the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and if found necessary rectification to be done as per satisfaction of E/C. The water proof coating to be protected from damage before screed over it. Water proofing brand Sika Topseal 109hi/Fosroc Brushbond RFX/Dr Fioxit Pidiffin 2K/MYK Aquafin TG. Product performance- Chemical base part A Acrylic copolymer, Part B Specially graded cementitious powdere density 1.6 kg/I (mixed density) at +27 degree C. Tensile strength - 2N/mm2 after 28 days (with fibre cloth) (according to ASTM D 2370) Pullout bond strength - 2 N/mm2 (concrete failure) (According to ISO 4624) slant-shear bond strength - 4N/mm2 (according to FIP 5.15) Elongation at break - 35% without fibre cloth and 20% with fire cloth (according to ASTM D 2370) |
| 58 | d. Protection of treated surfaces with PCC ; The treated syrface shound be covered with 25mm/50mm PCC of M-20 grade (1:1.5:3) with proper slope (1:120) towards the rain outlets in alternate panels of 2 mt X 2 mtr. Keeping 6mm gap between the panel joint integral water proofing admixture conforming to IS 2645 @ of 100ml per bag of cement to be added in the screed concrete (Paid separately for this items) All corners shall be chamfered with 150mm X 150mm fillet. The rainwater outlets shall be just leveled with the screed concrete to ensure smooth discharge of water - peripherial gaps between PVC pipe outlet and concrete surface should be packed properly with rich concrete nd the peripherial mouth to be sealed with mosture insensitive epoxy putty of sika India Pvt. Ltd/MYK schomberg/Dr. Fixit/Fosroc. For purpose of measurement the entire treated surfaces will be measured e, Grooves of PCC surface should be filled with polysulphide sealant. Brand - Sika India Pvt. Ltd. /MYK Schomberg/Dr. Fixit/Foscroc warranty for five years. |
| 59 | Providing and laying double charged Vitrified floor tiles in different sizes (thickness to be specificed by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622/ISO 13006 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting thenjoints with white cement and matching pigments etc. complete size of tile 600X600mm |
| 60 | Providing and fixing on wall face unplaqsticised- PVC moulded fitting/ accessories for unplaqsticised- PVC rain water pipes confirming to IS: 13592 TYPE A,including jointing with seal ring confirming to IS: 5382 leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 61 | Bend 110X110X110 |
| 62 | Shoe 110mm dia |
| 63 | Providing and fixing unplasticised PVC pipe clips of approved design to unplasticised PVC rain water pipes by means 50X50X50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 ( 1 cement : 4 coarse sand) and making good the wall etc. complete - 110mm |
| 64 | Providign and applying Plaster of Paris Putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete. |
| 65 | Carriage of materails |
| 66 | Cement |
| 67 | Chips - |
| 68 | Bricks 12km |
| 69 | Steel |
| 70 | ELECTRIFICATION WORK |
| 71 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 72 | Point Wiring in PVC Conduit, with Modular type Switch: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required. |
| 73 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc as required. |
| 74 | Supply and Fixing Light Plug Point with Modular Type Accessories: Supply and Fixing GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 15/16 amps modular socket outlet and 15/16 amps modular type switch, connection, painting etc as required. |
| 75 | Circuit / Sub-main wiring in PVC Conduit: Wiring for circuit / sub-main wiring along with earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required. |
| 76 | 2x1.5 Sqmm + 1x1.5 sqmm earth wire |
| 77 | 2x2.5 Sqmm + 1x2.5 sq mm earth wire |
| 78 | 2x4 Sqmm + 1x4 sq mm earth wire |
| 79 | 2X10sq.mm + 1X10sq.mm earth wire |
| 80 | 4 Ways (4+12 ways) double door |
| 81 | S/F 'C' series MCB:- Supplying and fixing 240 volts, 'C' series, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc, as required. |
| 82 | 6/32A Single Pole |
| 83 | 6/32A TPN MCB |
| 84 | S/F Ceiling Rose: Supplying and fixing 2 pin ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 85 | S/F Modular type electronic fan regulator: Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required. |
| 86 | ITC Exhaust Fan upto 450 mm sweep: installation of exhaust fan upto 450 mm sweep in the existing opening, including making the hole to cut the size of the above fan, making good the damage, including connection, testing, commissioning etc as required. |
| 87 | S/F Batten / Angle Holder: Supplying and fixing batten / angle holder including connection etc as required. |
| 88 | S.I.T.C of following rating surface mounted LED tube light fittings suitable for 230V, 50Hz, single phase supply etc. complete as required - 20/22W. LED tube light |
| 89 | Bulk head fitting with 9/10Watt CFL/LED |
| 90 | Supplying, 15/16 Watt LED bulb of approved make |
| 91 | Supplying Exhaust fan of 12\\" (300mm) of aproved make |
| 92 | Supply, installation, testing and commissioning of following size ceiling fan 3 blades confirming to IS:374:2019 including wiring the down rods of standard length (upto 30cm) with 1.5sq.mm. FR. PVC insulated copper wire suitable for 230V, 50Hz, single phase supply etc. complete as required. - 1400mm (56\\") ceiling fan |
| 93 | S.I.T.C. of following rating recess/surface mounted LED round/square shape down light luminaire with pressure die cast housing for single phase supply Voltage. Luminaire shall be confirm to IS:10322 Part -5/section 2 of IEC:62722 with all necessary accessories as required - 15/16W LED round down light - as CL |
| 94 | S.I.T.C. of following rating LED street lighting luminarie die cast housing and toughened glass cover (IP-66 portion) in existing pole/pipe for supply voltage 100-270V. AC, 50Hz. Luminaire shall be confirm to IS:10322 part - 5/section 3 and shall be complete with all necessary accessories as required - 60W LED street light |
| 95 | GI Earth Pipe Electrode: Earthing with G.I. earth pipe 4.5 mtr long , 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcol and salt complete as required. |
| 96 | S/F. 8SWG copper wire at 0.50 meter below ground level for conductor earth electrode including soldering etc. as required |
| 97 | Wiring for twin control light point with 1.5sq.mm FRPVC insulated copper conductor single/core cable in surface/ recessed PVC conduit 2 way piano type switch phenolic laminated sheet cover suitable size M.S. Box and earthing. |
| 98 | Power plug wiring in PVC conduit (2 X 4 sq,mm) - Wiring for light/power plug with 2 X 4 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, along with 1 no. 4 sq.mm. FR PVC insulated copper conductor single core cable for loop earthing etc. as required. |
| 99 | Supplying and fixing following modular switch/socket on the existing modular plate and switch box including connections . |
| 100 | Providing and fixing 6SWG dia GI wire on surface/or in recess for loop earthing along with existing surface/recessed conduit conduit/sub main wiring/cable as required . |
| 101 | Supplying and fixing call bell buzer suitable for single phase 230volts complete as rquried |
| 102 | Supplying and fixing 11 watt CFL etc. all complete as required |
| 103 | Installation, testing and commissioning of ceiling fan including wiring the down rods of standed length (utp 30 C length ) 1.5sq.mm FR PVC insulated copper conductor single core cable etc. as requrired |
| 104 | Supplying and fixing following rating four pole (three phase and neutral) 415 volts, residual current circuit breaker (RCCB) having a sensitivity current 30milli amperes in the existing MCB DB complete with connectio9ns, testing and commissioning etc. as required |
| 105 | Supplying fixing 2 amp DP switch complete as required |
| 106 | Supply of following size SLPE insulated armoured cable (make havel's polycab) as required 3.5 core 50sq.mm |
| 107 | Supplying and nlaying 25mm X 5mm G.I. strips at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required (jointing shall be done by overlapping and with 2sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 108 | Providing and fixing 25mm x 5mm G.I. strip on surface or in recess for connection etc. as required |
| 109 | Provioding and laying 1.1 KV grade aluminium armoured cable as per IS 1554 (Part I) heavy duty all cost complete including cost of brass compression gland, cable jointing and end termination as per specification and direction f E/I. |
| 110 | 3.5 core, 50sq.mm |
| 111 | Add 18% GST |
| 112 | Add 1% Labour Cess Please Enable Macros to View BoQ information |