Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | CIVIL WORK UP TO PLINTH LEVEL |
| 2 | 65.7Hydraulic excavator |
| 3 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources). |
| 4 | 5.1.2Providing and laying in position specified grade of reinforced cement concrete,excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mmnominal size derived from natural sources). |
| 5 | 5.22.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more. |
| 6 | 5.9.1Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete |
| 7 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 8 | 50.6.2.1Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x15 cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 15cm in: CM 1:6 ( 1 cement :6 coarse sand) etc complete. |
| 9 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand). |
| 10 | 22.12Supplying and applying bituminous solution primer on roof and or wall surface at 0.24 litre per sqm. |
| 11 | 50.2.25.1Filling with contractor's own earth ( excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m as per directionof site Engineer-in-charge. |
| 12 | 50.2.26.1Filling with contractor own earth (excluding rock) in open areas in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming andwatering, lead up to 50 m and lift up to 1.5 m as per direction of site Engineer-incharge. |
| 13 | CIVIL WORKS - SUPER STRUCTURE |
| 14 | 4.1.8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mmnominal size derived from natural sources) |
| 15 | 50.6.2.2Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc.complete. |
| 16 | 13.1.112 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand) |
| 17 | 50.13.19 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete. |
| 18 | OD270499/2025-2026Providing water cutting for sunshade, roof slab etc in cement mortor 1:3, 12mm thick & 15mm wide in lines and levels including cost, conveyance and unloading charge of materials, all labour charges, formwork,scaffolding charges,watering,curing etc. |
| 19 | 5.3Reinforced cement concrete work in beams, suspended floors, roofs, having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,staircases and spiral stair cases up to floor five level excluding the cost of centering,shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 20 | 5.2.2Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. up tot floor five level excluding cost of centering,shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | 4.1.2Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 22 | 5.22A.6Steel reinforcement for R.C.C work including straightening, cutting, bending, placingin position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more |
| 23 | 5.9.6Centering and shuttering including strutting, etc. and removal of form for:Columns,Pillars, Piers, Abutments, Posts and Struts |
| 24 | 5.9.3Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform. |
| 25 | 5.9.5Centering and shuttering including strutting, etc. and removal of form for:Lintels,beams, plinth beams, girders bressumers and cantilevers |
| 26 | 5.9.7Centering and shuttering including strutting, etc. and removal of form for:Stairs,(excluding landings ) except spiral - staircases) |
| 27 | 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 28 | 13.43.1Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer |
| 29 | 13.60.1Wall painting with acrylic emulsion paint of approved brand and manufacture to givean even shade:Two or more coats on new work. |
| 30 | 13.46.1Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 31 | 22.23AProviding & Applying polymer modified, flexible cementatious negative side waterproofing coating with elastic waterproofing polymers on interior wall plaster surface in three coats @14.35 kg /10 sqm. one coat of self priming of cementatiouswaterproofing polymer(dilution with water in the ratio of 1:1) and two coats of cementatious waterproofing polymer (dilution with water in the ratio of 3:1 ) after scrapping and properly cleaning the surface to remove pre-existing paint film & loose particles till plaster is visible, complete in all respect as per the direction of Engineerin-Charge. |
| 32 | 11.41.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm. |
| 33 | 50.9.1.1Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid forseparately), using good quality Anjili wood /jack wood |
| 34 | 50.9.5.1Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes including ISI marked M.S pressed butt hinges bright finished of required size with necessary screws. Using Anjili wood/ jack wood35 mm thick shutters. |
| 35 | 9.53Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) |
| 36 | 21.1.1.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions,i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading forglazing /paneling, C.P. brass/ stainless steel screws, all complete as per architecturaldrawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately):For fixed portionPowder coated aluminium (minimum thickness of powder coating50 micron) |
| 37 | 21.1.2.2For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paidfor separately)Powder coated aluminium (minimum thickness of powder coating 50 micron). |
| 38 | 21.2.2Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass /stainless steel screws etc. complete as per architectural drawings and directions ofEngineer - in- Charge.Pre- laminated particle board with decorative lamination on both sides |
| 39 | 21.3.2Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm). |
| 40 | OD270497/2025-2026Providing and fixing stainless steel 100 mm mortice latch and lock with 6 levers and apair of lever handles of approved quality with necessary screws etc. complete. |
| 41 | OD270498/2025-2026Providing and fixing stainless steel tower bolts (barrel type) with necessary screws etc. complete:150x10 mm |
| 42 | 9.100.1Providing and fixing aluminium handles, ISI marked, anodised (anodic coating notless than grade AC 10 as per IS : 1868) transparent or dyed to required colour orshade, with necessary screws etc. complete:125 mm |
| 43 | 9.101.2Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stoppe. |
| 44 | 9.103Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS: 1868) aluminium lever handles of approved quality with necessaryscrews etc . complete. |
| 45 | 9.83Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc.complete. |
| 46 | 9.97.4Providing and fixing aluminium tower bolts, ISI marked, anodised(anodic coating not less than grade AC 10 as per : 1868), transparent or dyed to required colour or shade,with necessary screws complete:150x10 mm. |
| 47 | 9.48.2Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to openings/ wooden frames with rawl plugs screws etc |
| 48 | 13.61.1Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work. |
| 49 | 13.48.2Finishing with Deluxe Multi surface paint system for interiors and exteriors using primer as per manufacturers specifications:Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 ltr/10 sqm of approved brand and manufacture. |
| 50 | 9.121Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of crosssection 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminated shall be moulded with fire resistant gradeunsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at thebottom to steady the frame. |
| 51 | 9.122.1Providing and fixing to existing door frames.30 mm thick Glas Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS : 14856,including fixing to frames. |
| 52 | 10.28Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nutsand bolts complete, i/c fixing the railing with necessary accessories & stainless steeldash fasteners, stainless steel bolts etc., of required size on the top of the floor or theside of waist slab with suitable arrangement as per approval of Engineer-in-charge,(for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 53 | 4.1.5Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mmnominal size derived from natural sources). |
| 54 | 11.20.3Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard,jointed with neat cement slurry mixed with pigment to match the shade of tiles,including rubbing and cleaning etc. complete on 20 mm thick bed of cement mortar1:4 ( 1 cement : 4 coarse sand).Dark shade pigment using ordinary cement. |
| 55 | 50.10.1Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
| 56 | 10.26.3Providing and fixing hand rail of approved size by welding etc. to steel ladder railing,balcony railing, staircase railing and similar works, including applying priming coat of approves steel primer.G.I. pipes |
| 57 | 12.50Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 58 | 12.4.2Providing ridges or hips width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete.0.63 mm thick with zinc coating not less than 275 gm/m2 |
| 59 | OD294807/2025-2026Suppling and fixing eve board made of FCB board 10mm thick as per required design including cost of materials, labor charges and hire charge of tools |
| 60 | WATER SUPPLY AND SANITARY WORKS |
| 61 | 17.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal designcomplete, including painting of fittings and brackets, cutting and making good thewalls and floors wherever required :W.C. pan with ISI marked white solid plastic seatand lid |
| 62 | 17.7.3Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require:White Vitreous China Washbasin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 63 | 50.17.1.5Supplying and fixing CP Health Faucet superior quality ( Jagur or equvalent make ) including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 64 | 50.17.1.1Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge. |
| 65 | 50.17.1.3Supplying and fixing CP Towel rod 60cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-incharge. |
| 66 | 17.72Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.. |
| 67 | 18.51.1Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore |
| 68 | 17.32.2Providing and fixing mirror of superior glass ( of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Rectangular shape 453x357 mm |
| 69 | 18.53.1 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nominal bore |
| 70 | OD270516/2025-2026Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement ,110x75mm PVC Multi Floor Trap without Jali. |
| 71 | 17.29Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 72 | 51.19.ST2Supplying and installing ready made PVC Septic tank including the cost of carriage,trenching, placing at the level below ground level as specified as per the direction of engineer in charge (Provision for CC/RCC/Sand/06mm aggregate for the preparation of bed shall be paid separately) 2. 15 to below 25 flush capacity. |
| 73 | OD270515/2025-2026Constructing soak pit of size 1m x 1m x 1m (Inside)using solid concrete blocks (30cm x20cm x 15cm) for walls, with cement-sand mortar (1:6), and an RCC top slab (100mm thick, reinforced with TMT bars of 8-10mm diameter) with proper inlet pipe connection, compacted base, and adequate curing. |
| 74 | 18.48Providing and placing on terrace (at all floor levels) polyethylene water storage tank :ISI 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the basesupport for tank. |
| 75 | 50.18.8.3.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge.Concealed work, including cutting chases and making good the wall etc. 25 mm pipe10kgf /cm2. |
| 76 | 50.18.9.14.2Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mmdia 6 Kgf/cm2 - External work - Exposed on wall. |
| 77 | 50.18.9.17.2Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall. |
| 78 | 50.18.9.19.2Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 -External work - Exposed on wall. |
| 79 | 50.18.9.8.2Providing and fixing PVC pipes includings of pipes with one step PVC solvent cement, trenching and refilling & testing of joints complete as per direction of Engineer in Charge. 75 mm dia 4 Kgf/cm2 |
| 80 | 50.18.9.9.2Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2 |
| 81 | 50.18.9.7.2Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2. |
| 82 | 50.18.9.20.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Elbow. |
| 83 | 50.18.9.20.2Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -63 dia 45 degree Elbow |
| 84 | 50.18.9.20.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 63 mm dia Bend |
| 85 | 50.18.9.20.5Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee. |
| 86 | 50.18.9.21Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Elbow. |
| 87 | 50.18.9.21.2Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75 mm dia 45 degree Elbow |
| 88 | 50.18.9.21.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement -75x75x75 mm dia Tee. |
| 89 | 50.18.9.21.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 75x75x75 mm dia Door Tee |
| 90 | 50.18.9.21.7Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Vent cowl. |
| 91 | 50.18.9.21.4Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 75 mm dia Bend. |
| 92 | 50.18.9.22.1Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Elbow. |
| 93 | 50.18.9.22.2Providing and fixing PVC moulded fittings / accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia 45 degree Elbow |
| 94 | 50.18.9.22.6Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110x110x110 mm dia Door tee. |
| 95 | 50.18.9.22.4 Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes,including jointing with PVC solvent cement- 110 mm dia Bend |
| 96 | 50.18.9.22.5Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee |
| 97 | 50.18.9.22.8Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes,including jointing with PVC solvent cement -110 mm dia Vent cowl |
| 98 | 18.19.2.1Providing and fixing gun metal non-return valve of approved quality (screwed end): 32 mm nominal boreHorizontal |
| 99 | 18.19.2.2Providing and fixing gun metal non-return valve of approved quality (screwed end): 32 mm nominal boreVertical |
| 100 | 18.18.3Providing and fixing ball valve (brass) of approved quality, High or low pressure,with plastic floats complete:25 mm nominal bore |
| 101 | ELECTRICAL WORK |
| 102 | 1.10.1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A |
| 103 | 1.10.2Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group B |
| 104 | 1.10.3Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVCconduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C |
| 105 | 1.11Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. |
| 106 | 1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 107 | 1.17.2Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm |
| 108 | 1.17.20Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm |
| 109 | 1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 110 | 1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 111 | 1.53.1 Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable |
| 112 | 90.4.1Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required. |
| 113 | 1.17.30Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 6 sq. mm |
| 114 | 1.17.31Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm |
| 115 | 1.19Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 116 | 1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 117 | 1.21.2Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 118 | 1.18.1Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor,unarmored telephone cable in the existing surface/ recessed steel/PVC conduit as required.1 Pair |
| 119 | 1.24.1Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch |
| 120 | 1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 121 | 1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 122 | 1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 123 | 1.24.6Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet |
| 124 | 1.24.7Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.TV antenna socket outlet |
| 125 | 1.24.8Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push |
| 126 | 1.32Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 127 | 1.33Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ woodenblock including connection etc as required. |
| 128 | 1.34 Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 129 | 2.10.1Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 130 | 2.10.4Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole |
| 131 | 2.11Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 132 | 2.12.1Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 133 | 2.13.1Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 134 | 2.13.2Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 135 | 2.14.2Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 136 | 2.15.2Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.40 amps |
| 137 | 5.17Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 138 | 5.19Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 139 | 5.4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having lockingarrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 140 | 90.10.3.32Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 141 | 90.10.3.33Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 142 | 90.12.7.27Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good thedamages , colour washing etc. as required.3.5 core 25 sq mm with factory made clamp |
| 143 | 9.1.20Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm) |
| 144 | OD270509/2025-2026Supply,marking,crimping RJ45 connectors /sockets and fixing to the existing enclosure and giving connection etc complete |
| 145 | OD270514/2025-2026Supply and Installation of NWR-6U-5555-GR D-Link Wall Mount Rack The D-Link NWR-6U-5555-GR Wall Mount Rack is a compact and sturdy 6U unit with a 550mm depth and width. It is ideal for housing networking equipment such as switches, patch panels, and power distribution units (PDUs). Features include: Tinted, toughened glass front door with lock 19-inch mounting rails with U-marking Roof-mounted fan unit for heat dissipation (90 CFM, 230V AC) 6-socket PDU (5 Amp) for power distribution Standard accessories: 1U cable manager and hardware packet |
| 146 | OD270503/2025-2026Supply, installation, testing and commissioning of 10W LED bulk head of departmental approved make ,giving connection etc. complete as required . |
| 147 | OD270505/2025-2026Supply, installation, testing and commissioning of 45W LED toplight with IP65 protection of departmental approved make as instructed by engineer in charge. |
| 148 | OD270500/2025-2026Supply and providing 9W LED Bulb in the existing batten holder. |
| 149 | OD270511/2025-2026Supply and providing 20W LED Tube of departmental approved make as instructedby engineer in charge. |
| 150 | OD270501/2025-2026Supply, installation, testing and commissioning of 5W Mirror lamp of departmental approved make, giving connection etc. complete as required. |
| 151 | OD270512/2025-2026Supply and providing of 200mm sweep light duty exhaust fan in plastic body with self opening louvers working on 230V Single Phase supply. |
| 152 | OD270506/2025-2026 Supply and fixing of weatherproof, dustproof, and three phase meter box made of 16 swg CRCA sheet powder-coated), suitable for outdoor use three single-phase energy meters, each connected through a 63A porcelain fuse unit and a neutral link. (L & T 63A Cubical Main Switch With Fuse Included) |
| 153 | 90.5.1.3Supply and fixing the following types of superior quality 250V A.C call bell on existing M.S. box and giving connections with required length of 3 core, 16 / 0.20mm 650/1100V grade PVC insulated and PVC sheathed round copper conductor flex wireconforming to relevant ISS or with the extended original wiring, earthing the MS box and making good the surface as required.Ding dong bell |
| 154 | OD270502/2025-2026Supply and fixing HAVELLS 63 A FP CHANGE OVER SWITCH or Equivalent(MR) |
| 155 | OD270510/2025-2026Supply and fixing HAVELLS 63 A FP 100ma RCCB or Equivalent(MR) |
| 156 | 2.3.1Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way, Double door |
| 157 | 2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door |
| 158 | OD270507/2025-2026Supply, installation, testing and commissioning of 0.5 hp mono block pump Crompton Champ Plus complete as connection. Or equivalent |
| 159 | 1.25Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 160 | 1.26Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 161 | 1.27.1Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module(75mmX75mm) |
| 162 | 1.56Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). |
| 163 | 1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 164 | 1.27.3Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mmX75mm). |
| 165 | 1.50.1Installation of exhaust fan in the existing opening, including making good the damage connection testing, commissioning etc. as required.Upto 450 mm sweep |
| 166 | 90.11.1.15Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/TP MCB as outgoing (IP 42/43) |
| 167 | OD295437/2025-2026Supply, installation, testing and commissioning of 8 port PoE Switch of departmental approved make, giving connection etc complete as required. |
| 168 | 90.4.5.4Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply |
| 169 | 90.11.1.10Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitableanchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43) Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail