| 1 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge. |
| 2 | Taking off carefuly damaged Illumination light, qila light/ frame from pillar/ iron post/ gates etc. for fixing new one as its place along with fixtures and wiring if necessary as per direction of Engineer-in-charge . |
| 3 | Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead (As per DSR 2023 code 15.14.1)Of sectional area 40 square centimetres and above |
| 4 | Demolishing RR masonry manually/ by mechanical means including stacking of serviceable material within lead up to 100 mtr and lift up to 2 mtr as per direction of Engineer-in-charge. |
| 5 | Demolishing Brick masonry manually/ by mechanical means including stacking of serviceable material within lead upto 100 mtr and lift upto 1 mtr as per direction of Engineer-in-charge |
| 6 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 7 | Providing and laying 75 mm thick compacted bed of dry brick aggregate of 40 mm thick nominal size including spreading, well ramming, consolidating and grouting with jamuna sand, including finishing smooth etc. complete as per direction of Engineer-in-charge. |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) including manufatured sand derived from Recycled Concrete Aggregate (RCA) upto 25% : 4 graded stone aggregate 20 mm nominal size including Recycled Concrete Aggregate (RCA) upto 25%.) |
| 9 | Random rubble masonry with hard stone including levelling up with lime mortar 1:1:1 (1 lime :6 coarse sand: 1surkhi). |
| 10 | Providing and laying cement concrete in retaining walls,return walls, walls (any thinkness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets, suken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement :2 coarse sand (zone-III derived from natural sources :4 graded stone aggregate 20 mm nominal size derived from natural sources) for coping work |
| 11 | Refixing of servisible ms grill on boundary wall and gate at spoecified location with necessary fixture and fitting including cutting, welding, hosting etc completer with lead upto 100 and lift upto 1 mtr as per direction of Engineer-in-charge : |
| 12 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 13 | Providing wood work in frames of doors, windows, clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately) |
| 14 | Providing and laying lime concrete 1:1:1:4 (1 lime : 1 sand: 1 surkhi : 4 brick aggregate of 20-40 mm nominal size) in flooring/foundation, including mixing, laying, compacting, finishing and curing etc complete with lead upto 100 mtr as directed by Engineer-in-Charge. |
| 15 | Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8 mm having with water absorption less than 0.5% and conforming to IS:15622 of approved make in all colours and shades in for outdoor floors such as footpath, court yard, multi modals location etc., laid on 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge |
| 16 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 17 | Providing and fixing heritage post top light including wiring cabling, earthing, testing & commissioning of the above light fixtures etc. complete. (As per approverd design) |
| 18 | Providing and fixing red sand stone bollard lights along the pathway as per approved design of standard height , including wiring cabling, earthing, testing & commissioning of the above light fixtures etc. to be fixed on CC block of size 0.3mtr X0.3 mtrX 0.45 mtr including 40 mm thick stone cladding to be provided with required mortar on exposed surface of CC block complete. |
| 19 | Providing and fixing signage boards (CNB/PNB/DNB) of red sandstone material, dressed and polished to match the monument stone, thickness 50–75 mm, fixed on PCC foundation (1:2:4) with stone supports, including engraving/lettering with enamel paint, finishing and curing complete |
| 20 | Providing and fixing SS braile board made of 2 mm thick of SS sheet of size 1.15 X 1 mtr of approved design and text at specified location as per the direction of eng-in-charge. |
| 21 | Providing and fixing MS chain barricading around garden, consisting of MS chains of approved thickness hung between MS posts including painting with primer and enamel paint, finishing and curing complete |
| 22 | \\"LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 85% INPUT VOLTAGE :140-270 volt AC, frequency 50/60 hz,operating tem range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5,Driver efficiency >85%,THD 70, under voltage and over voltage protection, EMIEMC As per CISPR 15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver& electical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000 K/4000 k/5700 k/6500 k(As per ANSI Bin) ,SDCM (Standard Deviation Colour Matching ) |
| 23 | Recess pointing of R.R stone masonry in lime surkhi mortar 1:1:1 (1 Lime, 1 surkhi,1 C.sand) with adhesive materials such as belgiri,molasses,gum & san including, racking out the joints, cleaning & washing the joints including carriage of water & material within a lead upto 100M & left upto 4.00M approx. |
| 24 | provision for reparing of broken/damaged 40 mm thick red sand stone frame including supply of required red sand stone and fixing material for protecting linear light as per existing pattern and design etc. complete |
| 25 | French spirit polishing : One or more coats on old work |
| 26 | painting with synthetic enamel paint on old wood work (one or more coats) |
| 27 | Providing and fixing of anti birds spikes inclduing all fitting and fixture at specified location to prevent beats |
| 28 | cleaning and re-inking of existing red sand stone CNB/PNB/DNB signage board placed at various location in qutub complex |
| 29 | \\"Dry stone pitching 22.5 cm thick including supply of stones and preparing surface complete.\\" |
| 30 | Providing and fixing ISI marked, IS : 1341, M.S. heavy weight bright finished butt hinges with necessary screws etc. complete : |
| 31 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. (125mm) |
| 32 | \\"Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies , M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a servicebale condition for the required duration as approved and removing it there after. The scaffolding system shall be stiffened with bracings , runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc.complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose.The payment will be made once irrespective of duration of scaffolding\\" |
| 33 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge |
| 34 | painting with oil type wood preservative of approved brand and manufacture:Painting with oil type wood preservative of approved brand and manufacture :New work (two or more coats) |
| 35 | painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on new work |
| 36 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement motar 1:3 ( 1 cement: 3 coarse sand) including pointion in white cement motar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately ) : 40 MM thick Red sand stone- exposed face fine dressed with rough backing |
| 37 | Providning and laying in position specified grade of reinforced cement concrete , excluding the cost of centering , shuttering , finishing and reinforcement- All work up to plinth level :1:2:4 ( 1 cement :2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 38 | Stone work ashlar punched (ordinary ) in superstructure upto floor five level in cement mortar 1:6 (1 white cement : 6 coarse sand) including pointing with white cement mortar 1:2 ( 1 white cement : 2 stone dust ) with an admixture of pigment matching the stone shade: Red sand stone Please Enable Macros to View BoQ information |