| 1 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 2 | M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed. |
| 3 | M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 4 | M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. |
| 5 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall/ceilling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 6 | M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care compound of altek/birla putty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. Note : Colour and make as approved by EIC/GE. |
| 7 | M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 8 | M&L for preparation of old surfaces by removal of existing treatment and applying one coats of distemper oil emulsion on wall/ceiling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 9 | M&L for preparation of old surfaces by removal of existing treatmen and applying two coats of white wash on surface of ceiling complete all as specified and directed. |
| 10 | Demolition of cement concrete unreinforced in of any desciption and in any position not otherwise specifically provided for (sunken floor) and concrete debris and rubbishoff to a distance n exc 100m complete all as specified and directed. |
| 11 | M&L for rendering 10mm thick in CM 1:3 with WPC in sunken slab complete all as specified and directed. |
| 12 | M&L for preparation of roof surface & applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3 mm thick reinforced wih polyster non wove fabric (wt not less than 150 gms/sqm) land on primed surface by forced application, joints to be touched hot and width of overlaps not be less than 150 mm complete all as specified and directed. |
| 13 | M&L, cement concrete 1:7:12 F-2 (40 mm graded stone aggregate) in lean concrete complete all as specified and directed. |
| 14 | M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.06 Sqm but not exc 0.11 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed. |
| 15 | M& L for Glazed ceramic jointless light/coloured group of size 350mmx450mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, incl dismantling tiles etc complete all as specified and directed. Note : Shade & design as approved by EIC/GE. |
| 16 | M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed. |
| 17 | Fixing only for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed. |
| 18 | S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe in repairs complete all as specified and directed. |
| 19 | Fixing only for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe in repairs complete all as specified and directed. |
| 20 | S&F of PVC flushing cistern low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern in repairs complete all as specified and directed. |
| 21 | S&F for Vitreous China wash basin (Pedestal pattern), White, flat back, size 550x400 mm incl brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper with and including PVC collapsible waste pipe of suitable length, fixed in repairs complete all as specified and directed. |
| 22 | Fixing only for Vitreous China wash basin (Pedestal pattern), White, flat back, size 550x400 mm incl brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper with and including PVC collapsible waste pipe of suitable length, fixed in repairs complete all as specified and directed. |
| 23 | S & F in repair Vitreous china urinals, half stall type (635x450mm) , complete including providing and fixing , bedding urinal against wall in cement mortar 1:2 , pointing around urinal back in cement , grating and union for discharge pipe, (Exclusive of fixing supply pipe to flushing cistern, trap & waste pipe complete all as specified and directed. |
| 24 | Taking down existing roof treatment of any description and any type complete all as specified and directed. |
| 25 | M & L for roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, incl Brushing neat cement slurry with 3.0kg of cement per sq. metreetc complete all as specified and directed. |
| 26 | M&L for Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified and directed. |
| 27 | M&L for PCC (1:2:4) nominal mix, type B-0, using 12.5mm graded stone aggregate in roof padding and surface finished even and smooth without using extra cement, complete all as specified and directed. |
| 28 | M&L for Making benching with PCC (1:2:4) type B0 (using 12.5mm graded stone agg) WPC along side wall adjoining to roof in concave shape complete all as specified and directed. |
| 29 | Removing plants / sherbs duct wall , junction with roots using herbicide chemical of existing brick or concrete for multistoried building at any storeyed and any height and match the surface with existing surface using 1:3 CM, complete all as specified and directed. |
| 30 | S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 500 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting, GI nipple and any fitting ,dismantling existing water tank complete all as specified and directed. |
| 31 | S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixed in any position incl 20 mm dia ball float valve with aluminium fitting,GI nipple and any fitting , tank cover dismantling existing water tank complete all as specified and directed. |
| 32 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \\" Tank cleaning on dt _______ \\" complete all as specified and directed. (a) Tank Capacit exc 250 Ltr but n exc 500 Ltr. |
| 33 | S&F for Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. for Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc and hoisting if required reconnecting and re-fixing in position. (incl writing in white paint of 150mm size \\" Tank cleaning on dt _______ \\" complete all as specified and directed. (a) Tank Capacit exc 500 Ltr but n exc 1000 Ltr. |
| 34 | Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed. |
| 35 | S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed. |
| 36 | S&F GI tubing 15 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. |
| 37 | Fixing only in repair steel tubing and connection 15 mm dia bore to wall and laid in floors, complete all as specified and directed. |
| 38 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed.. |
| 39 | S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. |
| 40 | Fixing only in repair steel tubing and connection 20 mm dia bore to wall and laid in floors. |
| 41 | S&F for Gun-metal globe or gate valves of 20mm bore , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. . |
| 42 | Dismantling wall and ceiling boards (fibre pulp insulation etc) or insulation boards, slabs, blankets any thickness, incl cover fillets complete all as specified and directed. |
| 43 | S & F for plain gypsum board panel 10mm thick on ceiling with and incl necessary Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and the weight of the board shall be not less than 7 kg per sqm incl dismantling of walls and ceiling board any type complete all as specified and directed. |
| 44 | M&L for WPC primium quality panelling 9 to 10 mm thick on ceilling including with necessary frame work in POP Design and any colour approved by engr-in-charge, inclusive of fixing on to wall/ceiling incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed |
| 45 | M&L in repair for WPC primium quality wall panelling 9 to 10mm thick any colour/design approved by engr-in-charge, inclusive of fixing on to wall incl moulding end caps fixed with PVC sleeves and screws as required at site complete all as specified and directed |
| 46 | Dismantling of AC/GI sheet (corrugated, semi corrugated etc) of any thickness incl ridges hips valleys as in roof coverings complete all as specified and directed. |
| 47 | Dismantling wrought Iron or mild steel work of any description not otherwise provided for wind tie complete all as directed and specified. |
| 48 | S& F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specifed and directed. |
| 49 | S & F for rolled sections as in main and cross beams, hip and jack rafters,truss, purlins where connected to common rafters and running rails, cleat or other connecting plates cutting, welding including Nut Bolts, Fe 410-W(Gde -E-250) quality A all as specified and directed. |
| 50 | All as per item No 49 above but fixing only. |
| 51 | S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 52 | S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 53 | M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed. |
| 54 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed . |
| 55 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 56 | All as per item No 55 above but except bricks. |
| 57 | M&L for rough cast (Grit) finish plaster with a mixture consisting of crushed stone or fine gravel aggregate mixed with coarse sand and cement in the ratio of 1:1:1 over & including 12mm thick rendering in cement mortar 1:3 on fair faces of brick masonry or concrete surfaces of walls complete all as specified and directed. |
| 58 | M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 59 | M & L for preparation of old stone, concrete surfaces of any description over 10 CM width or girth and applying one coat of plastic emulsion paint (Weather Coat) on old footpath/colour tiles/ kerb stone etc complete all as specified and directed. Note : Colour and pattren as per approved by EIC/GE. |
| 60 | M & L for precast cement concrete loveres and jallies, 25mm thick, type B0 1:2:4 (12.5 mm graded stone agg), set in CM 1:4, including all mouldings complete all as specified and directed. |
| 61 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as directed. |
| 62 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and directed. |
| 63 | M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone agg) as in plinth protection / path/ any paved area complete all as specified and directed. |
| 64 | M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded stone aggregate) as in sub base complete all as specified and directed. |
| 65 | M&L for 60 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment,(M-35) grade, complete all as specified and directed. Note:- Colours as approved by EIC /GE. |
| 66 | M&L for 60 mm thick machine cut precast concrete inter locking paver blockexcept tile ,(M-35) grade, complete all as specified and directed. Note : -Colours as approved by EIC /GE. |
| 67 | M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade, complete all as specified and directed. Note :- Colours as approved by EIC /GE. |
| 68 | M&L for 80 mm thick machine cut precast concrete inter locking paver block except tile ,(M-40) grade, complete all as specified and directed. Note :- Colours as approved by EIC /GE |
| 69 | M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 70 | M & L for Heavy duty Vitrified outdoor Parking tiles of size in 400 x 400 x 15 to 20 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 71 | M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as specified and directed. |
| 72 | M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as Spd & directed . |
| 73 | M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade 'A' in on concrete slab 100mm complete all as specified and directed. |
| 74 | M&L for providing and laying ator near ground level factory made kerb stone of M-25 grade cement concrete inposition to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed. |
| 75 | Removing excavated material to a distance not exceeding 50 m and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed. Please Enable Macros to View BoQ information |