| 1 | B/R Works |
| 2 | M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in bed block of hold fast coping including necessary formwork complete all as specified and directed |
| 3 | S&F MS Plate (Plain or chequered) channels, square cut or notched (ordinary and countersunk) forming holes, without any attachment etc of Ge-290 (Gde E-165) including fabrication, erection and fixing complete all as specified and directed. |
| 4 | S&F MS Bolts , purpose made with hexagonal or square head one end and other or screwed both ends each screwed end to be fitted with washers and one hexagonal square not exc 30cm long and dia of neck exc 20mm but n exc 25mm of Fe-290 (Gde E-165) including erection and fixing complete all as specified and directed. |
| 5 | S&F Fe-290 (Gde E-165) steel work in Roof trusses (Framed), trussed, purlins , crane gantries, rails and fastening and heavy bracket framing made of beam, tee angle channel hollow section or flat section) including distance pieces, cleat etc complete all as specified and directed. |
| 6 | S&F Pre-painted galvalume aluminim zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength 550 MPA as in roof covering / cladding to wall fixed with self tapping screws complete all as specified and directed. |
| 7 | M&L for preparation of new or untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 8 | S&F plain galvanised mild steel sheeting 0.80mm thick fixed in ridges valley gutters crumple joint covers and similar items with grade of zinc coating 275 complete all as specified and directed. |
| 9 | M&L for Brick work with sub class B bricks straight or curved on plan exc 6 mtr mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 10 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 11 | M & L for rendering 15 mm thick on fair faces of brick wall cement finished fair & even in CM 1:4 complete all as specified and directed. |
| 12 | M & L for rendering 15 mm thick on fair faces of brick wall in CM 1:6 complete all as specified and directed. |
| 13 | M&L for preparation of new plastered surfaces of any description not otherwise described and applying two coat of exterior acrylic emulsion over a coat of water based exterior primer in disruptive / camouflaging pattern of four shades complete all as specified and directed. |
| 14 | M&L for preparation of new plastered wall surfaces complete all as specified and applying the following: -(a) Applying wall care putty, in two coats on wall surfaces & smoothening the surfaces with sand papers/ mechanized sanding etc., (preparatory to paint as directed), complete all as specified. (b) Two coats of acrylic distemper/distemper oil emulsion (OBD) over and including a coat of acrylic emulsion primer, complete all as specified and directed. |
| 15 | E/M Works |
| 16 | M&L for pointing wiring with 1.5 sqmm (nominal area) PVC insulated FRLS H, unsheathed, multistrand, 1100 volts grade copper conductor cable single core. drawn through in and including non metalic concealed PVC conduit medium grade of suitable size as per SSR Part 1 and its accessories including one run of 1.5 sqmm PVC insulated copper conductor cable green in colour for continuous earthing including MS terminal box Module type alongwith modular white cover plate with frame all as specified. Note:- surface conduit shall be laid in ceiling portion only.for One 3 pin 5 amps socket point on independent board (Modular type) |
| 17 | S&F Switch Modular 06 Amp one way one module complete all as specified and directed. |
| 18 | S&F Socket outlet 2/3 pin, combined 2 module, 6 Amps Modular type complete all as specified and directed. |
| 19 | S&F Socket outlet 2/3 pin, 6/16 Amps Modular type two module complete all as specified and directed. |
| 20 | S&F Switch 16 Amps, 1 way, 1 module, Modular type complete all as specified and directed. |
| 21 | Note For item No.17 to 20 : switch board to be illuminated with suitable LEDs for visibility in dark. |
| 22 | M&L for Sub main wiring (with approved colour coding as per IS) with single core FRLS H PVC insulated multi stranded copper conductor 1.1 KV grade (main cable: number of runs as indicated below along with single core FRLS H PVC insulated multi stranded copper conductor 1.1 KV grade for earthing in conduits including taking down old , complete all as specified for the following: - |
| 23 | 2 runs of 1.5 Sq. mm main cable + 1 run of 1.5 Sq. mm earth cable |
| 24 | 2 runs of 2.5 Sq. mm main cable + 1 run of 2.5 Sq. mm earth cable |
| 25 | 2 runs of 6 Sq. mm main cable + 1 run of 6 Sq. mm earth cable |
| 26 | 4 runs of 6 Sq. mm main cable + 1 run of 2 Sq. mm earth cable |
| 27 | S&F Rigid non-metallic PVC conduit of external dia 32 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 28 | S&F Rigid non-metallic PVC conduit of external dia 25 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 29 | S&F Rigid non-metallic PVC conduit of external dia 20 mm exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. |
| 30 | S&F (Load line) sheet metal enclosure (DB) duble door triple pole and neutral 4 way, 415 volt with 200 Amps rated bus bar in and including MCCB 4 pole 63 Amps, 16 KA, 415 Volts complete all as specified and directed. |
| 31 | S&F sheet metal enclosure (DB) double door single pole and neutral 8 way,240 volt with 200 Apms rated bus bar complete all as specified and directed. |
| 32 | Note For item No.27 & 28 : sheet metal enclosure to be illuminated with suitable LEDs for visibility in dark. |
| 33 | S&F MCB suitable for 240 volt AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 6 to 32 Amp, complete all as specified and directed. . |
| 34 | S&F MCB suitable for 240 volt AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 kA, 'C' curve type of rating 32 Amp, complete all as specified and directed. |
| 35 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) TP 63 Amps, C Curve (10KA) complete with connection testing and commissioning complete all as specified and directed. |
| 36 | Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 37 | Supply & fix heavy duty industrial type, wall mounting Air Circulator fans 230 volts single phase,1440 RPM, copper wound motor, aluminium alloy blades, double ball bearing, adjustable tilt, closed mesh guard, 450 mm sweep complete all as specified and directed. |
| 38 | Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 39 | Material & Labour for earthing complete with Galvanised steel earth plate electrode of size 600x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below normal ground level), with top edge of earth plate not less than 1.5 m below normal ground level connected to earth lead wire 4 mm dia by means of nuts, bolts and washers of galvanised iron and earth lead protected by galvanised iron pipe 15 mm bore (medium grade) and connected to earth test point and including cement concrete pit in PCC (1:3:6) type C-1 (using 20mm graded aggregate) and pre-cast RCC cover slab of suitable size, reinforced with 8mm dia TMT bars both ways and one handle for lifting made with 10 mm dia mild steel bar, funnel, wire mesh 20 mm bore galvanised (medium grade) for watering, charcoal and salt in alternate layers including necessary execution and earth work in any type of soil complete. NOTES : (a) The unit rate includes earthing lead and protection pipe upto 7.5 metre from top of earth plate.(b) Factory made PCC pit with RCC cover shall be fixed at least 500mm away from the earth pit.(c) Earth resistance should be less than five Ohm. In case the test results are not found below five Ohm, complete earthing shall be redone by contractor without any extra cost to Govt . |
| 40 | Supply, laying, jointing & testing of LT XLPE insulated cable screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor conforming to IS-7098 (Part-I -1988) laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing including taking down existing cable of sectional area 35 Sqmm, 3.5 core complete all as specified and directed. |
| 41 | Excavation in trenches n. exc 1.5 m wide for foundations, laying cables/ pipes etc. not exceeding 1.5 m deep for laying/taking out of cables and foundation of pole etc and getting out in SOFT/LOOSE soil complete all as specified and directed. |
| 42 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 43 | Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 44 | M&L for sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 10mm thick) after laying of cables in trenches/ducts complete all as specified and directed. NOTE:- Punned down thickness (over all 180 mm) shall be considered for measurement and payment. |
| 45 | M&L for bricks protection with locally available sub class 'B' bricks (Old size), laid flat and dry perpendicular to the direction of cable adjacent to each other, in trenches over the cable for protection complete all as specified and directed |
| 46 | M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. NOTE:- Supply only GI pipe shall be measured and paid for separately under respective item of BoQ. |
| 47 | S&F steel tubes 40 mm bore ‘light grade’, galvanized with all fittings and fixed to poles/ walls/ under floors/ under road etc complete all as specified and directed. Please Enable Macros to View BoQ information |