| 1 | Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum , getting out, returning, filling in and raming earth or broken , in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and as directed by Engineer-in-Charge. |
| 2 | M&L for cement concrete type C-2 1:3:6 (40 mm graded aggregate in foundations,filling and mass concrete complete all as specified and as directed. |
| 3 | S&F Structural Steel Fe-410- W(Gde E-250) quality 'B' Rolled sections as in Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.tes complete all as specified and directed. |
| 4 | S&F 0.50mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified complete all as specified and directed. |
| 5 | S&F 2mm thick fibre glass reinforced translucent corrugated/ plain sheeting with two corrugation side lap fixed with J-type or L-type hook bolts complete all as specified and as directed. |
| 6 | M&L for preparation of new steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 7 | M&L for cement concrete type B-1, 1:2:4 (20 mm graded aggregate) as in roof and parapet wall junction, roof benching, kerbs, mud stop, coping, rounded or chamfered on edges and all other similar works including form work complete all as specified and as directed. |
| 8 | Surface excavation in soft /loose soil not exceeding 30 cm deep and averaging 15 cm deep and getting out complete all as specified. |
| 9 | Excavating in trenches n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts wells cespits, manholes, pier holes etc n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed |
| 10 | Returning filling in layers including leveling watering and well ramming in layers n.exc 25 cm thick compelte all as specified and directed. |
| 11 | Removing surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exc 1.5 m above the starting point. |
| 12 | M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in foundation filling, sub base for floors etc complete all as specified. |
| 13 | M&L for brick work with sub class 'B' old size bricks straight or curved on plan exc 6 M mean radius built in cement mortar 1:6 all as specified. |
| 14 | M&L for brick work with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed |
| 15 | Use & waste of formwork to sides of concrete foundations,footings,bases or column,raft and raft beams,sides and soffits if any of foundations and plinth beams and similar work,vertical or batter etc rough finished surface of concrete complete all as specified and directed. |
| 16 | Use & waste of formwork to sides of pillars,posts,struts,piers,columns and stanchions ect fair finished surfaces of concrete complete all as specified and directed. |
| 17 | Use & waste of formwork to sides and soffits of floor or roof beams, beams haunchings, girders, bressummers, lintels, cantilever, shelves including supports, overhangs, etc also splays between floors and beams etc rough finished surfaces of concrete all as specified and directed |
| 18 | Use & waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified. |
| 19 | Use & waste of formwork to edges of concrete flats, treads breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide. |
| 20 | M&L RCC(Design Mix) M-20 , 20mm graded stone aggregate as in foundations including rafts,footings,foundations beams ,bases of column etc complete all as specified and directed. |
| 21 | M&L RCC(Design Mix) M-20, 20mm graded stone aggregate as in columns,pillers,piers,posts and structs etc complete all as specified and directed. |
| 22 | M&L RCC(Design Mix) M-20, 20mm graded stone aggregate as in beams,cantilevers,bressummers,lintels over 1.5 m span complete all as specified and directed. |
| 23 | M&L RCC(Design Mix) M-20, 20mm graded stone aggregate as in slabs supported on walls,beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed. |
| 24 | M&L of TMT bars 10 mm dia and over, cut to length bent to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed ) not less than 0.9 mm dia all as specified. |
| 25 | Ditto all as per item No 24 above but 5 mm dia and over upto and including 10 mm dia in stirrups spaces and binders |
| 26 | M&L 15mm thick cement plaster in cement mortar 1:4 on brick or concrete surface finished even and fair without using extra cement all as specified |
| 27 | M&L 10mm thick cement plaster in cement mortar 1:6 on brick or concrete surface finished even and smooth without using extra cement all as specified and directed. |
| 28 | M&L for fine sand bed under floor and all other similar works complete all as directed by Engr-in-charge. |
| 29 | M&L for hard core of gauge n.exc 63 mm deposited spread and leveled in layers n.exc 15 cm thick watered and ramed to a true surface complete all as specified and directed. |
| 30 | M&L for 75 mm thick PCC (1:4:8) type D-2 (using 40 mm graded aggregate) as in sub base and all other similar works complete all as specified and directed. |
| 31 | M&L for machine cut kota stone slab flooring 18–20 mm thick over 15 mm thick cement screed (1:6) base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polish complete all as specified and directed. |
| 32 | M&L for Kota stone slab 18–20 mm thick in skirting, etc. over 10 mm thick cement plaster (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite polish, complete all as specified and directed. |
| 33 | S&F Pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall,fixed with self tapping screws complete all as specified and directed. |
| 34 | S&F Rolled sections as in post/pilllars where connected with angle cleats or other connecting plates etc,of Fe 410-W(Gde E-250) Quality 'B' including fabrication,erection and fixing complete all as specified and directed. |
| 35 | S&F Mild steel plates(plain or chequered) channels,square cut or notched(ordinary and counter sunk) forming holes,without any attachment and fixing complete all as specified and directed. |
| 36 | M&L 100 mm thick Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in subbase of interlocking , complete all as specified and directed. |
| 37 | Providing and laying 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, driveways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. |
| 38 | M&L for preparation of new plastered surfaces and applying two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 39 | M&L 75mm thick, PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) as in plinth protection, shall be laid in 1:20 slope. The concrete shall be laid at a stretch not exceeding 3-meter in length. Joint gap between the adjoining slab, at corners and at junctions of wall shall not exceed 10mm in width and shall be sealed with mastic filling i.e. one part of bitumen of grade 85/25 garde mixed with 3 part of sand. Top surface of concrete shall be finished even and smooth without using extra cement. Joints shall be provided at not more than 3-meter interval at corner and junction walls complete all as specified and directed. |
| 40 | S&F 25 mm bore galvanised iron steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed . |
| 41 | S&F 20 mm bore galvanised iron steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed . |
| 42 | S&F 20 mm dia gun metal, globe gate valves, with iron wheel head, screwed both ends for iron pipe of 20 mm dia complete all as specified and as directed. |
| 43 | Cutting existing CI / GI pipe 40/50/80 mm bore including run lead joints of suitable size with necessary fittings complete all as specified and as directed. |
| 44 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 1.5 Sqmm (nominal area) in and including 20mm dia non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 1.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for the followings :- (a) One light/fan/Bell Point controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 45 | ditto all as per item No 44 above but for one socket outlet on the same board controlled by one single pole one way switch |
| 46 | ditto all as per item No 44 above but for one 5 amps socket outlet independent controlled by one single pole 5 Amp switch. |
| 47 | M&L for point wiring with PVC insulated unsheathed single core FRLSH multistranded copper conductor cable IS-694 marked of size 2.5 Sqmm (nominal area) in and including non metallic rigid PVC conduit with all accessories if require such as bends,reducers, spacers, saddles, junction boxes bakelite sheets, wooden rectangular boards / round blocks(for housing lamp holders and light fittings etc) and existing mild steel pressed / cast iron sunken boxes of suitable size for mounting switches / bell pushes / sockets, fan regulator etc covered with new 3 mm thick laminated bakelite sheet top cover including continuous earth wire cable of size 2.5 Sqmm unsheated stranded copper conductor with green PVC FRLSH insulation connected to common earth dolly complete all as specified and directed for one 3/5 pin 15 Amps switch socket out let on the independent board controlled by one single pole one way switch. Note:- Cutting chases for conduits and sunken boxes and making good to walls, floors etc, in case of recessed and concealed conduit wiring are included in item of taking down point wiring carefully. |
| 48 | S & F Modular Switch one way 6 A, 1 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 49 | S & F Modular Switch one way 16 A, 1 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 50 | S & F Modular Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 51 | S & F Modular Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed. Make - Precision/Anchor/Havells/Legrand |
| 52 | S & F Modular white cover plate including GI box inner, 3 module complete all as specified & directed. Make : Precision/Anchor/Havells/Legrand |
| 53 | S & F Modular white cover plate including GI box inner,6 module complete all as specified &directed. Make : Precision/Anchor/Havells/Legrand |
| 54 | S & F Modular white cover plate including GI box inner,8 module complete all as specified &directed. Make : Precision/Anchor/Havells/Legrand |
| 55 | S&F Lamp holder PVC/Polycarbonate,isolated with back plate suitable for batten fittings ISI marked complete all as specified and directed. including 10W LED Bulb omplete all as specified and directed. |
| 56 | Supply, hoist, fix and connect Ceiling Fan complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed. |
| 57 | S&F LED tube light fitting 20 Watt 4 feet long decorative ultra slim linear LED lighting three colour CCT Change LED Batten Which can change the Colour of batten FROM WHARM WHITE TO natural white to cool whitewhite the help of a simple toggle switch, fixture with extruded polycarbonate,environmental friendly, energy efficient 230V, complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 58 | S&F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impactand corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed. |
| 59 | S&F in repairs sheet metal enclouser double door factory made powder coated out of CRCA mild steel sheet 1.2 mm thick wih metallic painting white series pre-wired SPN DBs, 240 Volts 200 Amps rated bus bar,Neutral link,Earth bar and Din rail, 8 ways dust and vermin proof suitable for incorporation of MCBs duly concealed in wall and making good to distrubed surface and colour matching complete all as specified. |
| 60 | S&F Miniature Circuit Breaker (MCB) Single Pole (SP) current carrying capacity 6 to 32 Amp, 240V, breaking capacity 10 KA, type 'B' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 61 | S&F Miniature Circuit Breaker (MCB) Single Pole and Neutral (SPN) current carrying capacity 32 Amp, 240V, breaking capacity 10 KA, type 'C' curve in the MCB DB Complete with connection testing and commissioning complete all as specified and directed. |
| 62 | M&L in repairs submain wiring with two single core PVC insulated FRLSH cable with Copper conductor unsheathed cable of size 6.0Sqmm drawn through in and including 25mm dia non metallic rigid PVC conduit with all accessories including one 6.0Sqmm PVC insulated FRLSH cable with Copper conductor unsheathed cable single core for continuous earthing including taking down existing submain wiring and conduits etc complete all as specified and directed. ( Note : Two run of single core PVC insulated cable with Copper conductor unsheathed cable of size 6.0Sqmm and one run of 6.0Sqmm PVC insulated copper conductor single core (2x6.0Sqmm+1x6.0Sqmm earth wire) and one run of PVC conduit shall be measured as single run) |
| 63 | M&L for Earthing complete with Galvanised Iron earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at (Earth pit not less than 2.25m deep below ground level) a depth not less than 2.25m below normal ground level with top edge of earth plate at depth not less than 1.5m below normal ground level surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connection by using 4mm dia galvanised earth wire by means of bolts, nuts, check nuts and washers of galvanized iron and protected by 15mm bore GI pipe light grade connected to main switch board or main control board and 20mm bore GI pipe light grade for watering and including funnel, wire mesh, 80mm thick pre-cast RCC (1:2:4) type B-1 cover reinforced with hard drawn steel wire fabric weighing not less than 4Kg/Sqm in lieu of CI cover, PCC (1:2:4) type B-1 pit/chamber including all necessary excavation: and earth work, form work, disposal of surplus soil to a distance not exceeding 50m all as specified and al shown in Electrical Plate No.3 of MES Standard Schedule of Rates 2009 Part-I complete all as specified and directed.Note:- (i) The unit rate shall deemed to include for Test point, PCC pit, 4mm dia GI earth wire from top of the earth plate up to 7.5m above ground level. In case 15mm bore GIprotection pipe required is less than 7.5m, no price adjustment shall be made. (ii) PCC pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate.(iii) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. |
| 64 | Supplying, laying, jointing, testing and commissioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured,electric power cables (heavyduty) with aluminium conductor, 1100 volts Earthed, grade cross sectional area 16 Sqmm 2 Core nominal cross section area complete all as specifiedMake : Universal Cables, PolyCab and Finolex. |
| 65 | Supply and laying brick common burnt sub class ‘B’ old size and for protection of cable laid in trenches for underground cable of compressive strength not less 75 Kg/Sqcm complete all as specified and directed. |
| 66 | M&L for sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed.(Excavation and earth work measured separately).Note- Punned down thickness shall be measured and complete all as specified and directed. Please Enable Macros to View BoQ information |