| 1 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed by Engr-in-Charge. |
| 2 | M&L rendering 15mm thick cement plaster in CM (1:4) incl making the surface finished even & fair without using extra cement on brick/concrete surfaces complete all as specified and directed by Engr-in-Charge. |
| 3 | M&L rendering 15mm thick cement plaster in CM (1:6) incl making surface finished even & smooth without using extra cement on brick/concrete surfaces complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for two coats of oil bound distemper on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engr-in-Charge. |
| 5 | M&L for two coats of cement based paint on newly plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for prepration of old plastered or unplastered surfaces of walls and applying one coat of cement base paint , complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for prepration of old plastered or unplastered surfaces of walls and applying two coats of cement base paint , complete all as specified and directed. |
| 8 | M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coat of white wash on wall, complete all as specified and directed by Engr-in-Charge. |
| 9 | M&L for preparation of old surfaces (plastered or unplastered) of walls including cornices, pilasters etc including brooming or steel wire brushing, scrapping down smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots and applying two coat of white wash on ceiling complete all as specified and directed by Engr-in-Charge. |
| 10 | M&L for prepation of old painted wooden based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel Paint, complete all as specified and directed by Engr-in-Charge. |
| 11 | M&L for prepation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying one coat of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge. |
| 12 | M&L for prepation of old painted steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge. |
| 13 | M&L for preparation of existing old surface of chequred tile, interlocking tile etc and applying two coats of floor guard paint of specified tint using Roller/Brush complete all as specified and directed by Engr-in-Charge. |
| 14 | Dismantling of floor hearth and wall tiling including cement mortar bedding (but not backing) and removing serviceable like to store and rubbish off the premises., complete all as specified and directed by Engr-in-Charge. |
| 15 | M&L for Non-skid coloured tiles 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bed or beddding layer of CM 1:4 complete all as specified and directed by Engr-in-Charge. |
| 16 | M&L for Vitrified coloured/light tiles 600x600x10mm thick as in floors set and jointed in neat cement slurry and pointed in coloured cement to match over 15mm thick screed bed or beddding layer of CM 1:4, topping layer finished even and rough complete all as specified and directed by Engr-in-Charge. |
| 17 | M&L for Glazed ceramic coloured tiles of size 450x300x7 mm thick on vertical surface such as in dado/skirting/risers to steps etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles laid over and including 10mm thick rendering in CM (1:4) complete all as specified and directed by Engr-in-Charge. |
| 18 | S& F in repair one piece EWC with soft closing seat cover and fittings complete of size 710x370x745mm, modern curvy design with flushing efficiency 3.90/2.10 LPF, the shade of EWC to be approved by Engr in Charge, complete all as specified and directed. |
| 19 | Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15cm thickness below or above ground level, complete all as specified and directed by Engr-in-Charge. |
| 20 | M&L for 25mm thick PCC 1:2:4 type B-0 as in floor finished even and rough to receive further floor finishes or similar works complete all as specified and directed by Engr-in-Charge. |
| 21 | S&F in repair stainless steel squatting pan of pattern “long pan”, size 580x440mm standard with ‘P’ or ‘S” trap, front or back inlet and foot rests, any pattern (excluding flushing cistern and flush pipe) complete all as specified and directed by Engr-in-Charge. |
| 22 | S&F in repairs vitreous china wash basin white, flat back of size 630x450mm excluding taps, waste pipe, chain and plug and procelain stopper but including brackets complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F in repairs 32mm dia PVC waste pipe for WHB, urinals etc complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F in repair Pillar taps cast coper alloy,with capstan head 15mm bore screwd down high pressure with or without lettred 'hot' or 'cold' with long screwed shanks and fly nuts,screwed for iron PIpe.chromium plated fancy type complete all as specified and directed by Engr-in-Charge. |
| 25 | S&F in repairs 15mm dia bib tap standard of PTMT of any colour high pressure screwed for iron pipe and fixed complete all as specified and directed by Engr-in-Charge. |
| 26 | S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed by Engr-in-Charge. |
| 27 | S&F in repair grating doom 125mm dia with or without hole complete all as specified and directed by Engr-in-Charge. |
| 28 | Taking down Chowkhats or frames exc 1.5 sqm but nexc 4 sqm with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr-in-Charge. |
| 29 | S&F in repair Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws,incl taking out old section, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 30 | S&F Sheet glass of 4.8mm thickness,ordinary quality and glazing with oil putty in square exc 0.5 sq. m in each pane complete all as specified and directed by Engr-in-Charge. |
| 31 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars,etc, but excluding ashlar facings, dressed stonework and precast concrete articlescomplete all as specified and directed by Engr-in-Charge. |
| 32 | M&L for Pre-cast cement concrete type C-1 block masonry with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate), exc. 10 cm in width andn setting in mortar, complete all as specified and directed by Engr-in-Charge. |
| 33 | Note : Deduction for amount of Rs. 20700.00 as listed in Schedule 'A' Part-II (Schedule of Credit) shall be made while awarding of contract. Please Enable Macros to View BoQ information |