| 1 | 'Notes: (i) Please refer Schedule 'A' Notes of tender documents. |
| 2 | Demolition of brick work or stone/boulder masonary built in cement mortor incl all quoins,arches.pillars etc complete all as specified and as directed. |
| 3 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius bulit in CM 1:6 complete all as specified and as directed. |
| 4 | M&L for surface preparation of exiting surfaces must be clean,even and sound conctrete. remove oil, dirt, laitance and cutting and opening cracks to a depth of 10x10mm V or U shape by mechanical means. Cleaning all the dirt and loose particles by air pressure and wetting crack to attain saturated surface dry (SSD) condition. Filling the crack using Repair Polymer modified cement mortar and using AP Smartcare Repair Polymer over pipe and Internal side of concrete followed by filing high strength non shrink grout for a gap of up to 20mm (between pipe and concrete) before treating the surface with Waterproofing layer and supplying and applying Smart Care Damp Proof Ultra, fiber reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflectivity Index (SRI) of 105 on top of roof in three coats @ 1.8 litre/sqmt to be reinforced, having minimum elongation of 350%, tensile strength 2.9 Mpa and shall have crack bridging ability of up to 2.5mm and shall resist 10bars of hydrostatic pressure, reduces surfaces temperature up to 10 degree Celsius also IGBC certified (Indian Green Building Council) and Certificate will be provided by company. The system consists of self priming with 33% water dilution followed by two undiluted coats of Damp Proof ultra , the fibre mesh of 40 to 50 gm/sqm must be sandwich between 1st and 2nd coat of Damp Proof Ultra. (dry film thickness of complete application/system not less than 500 microns) and Ponding test to be done after 48 hrs of application of material by filling of water on surface at a average depth 25 mm upto 72 hrs from filling of water complete all as specified and directed by GE.Note:- Work shall be done by authorised applicator such as mentioned in appendix 'B' here-in-after and10 years Waterproofing warranty shall be submitted by applicator. |
| 5 | Taking down cement plaster on brick or stone walls/ceiling etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 6 | M&L for Rendering 15mm thick on brick or concrete surface in Cement mortar 1:4, mixes with integral liquid water proofing compound as per manufacturers instructions finishing surface even and fair w/o using extra Cement, complete all as specified and directed.Note: Liquid WPC will be measured and paid separately under respective item of this schedule. |
| 7 | Material & Labour for rendering 10 mm thick on fair faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed. |
| 8 | Material & Labour for rendering 5 mm thick on fair faces of concrete surface as in ceiling in cement mortar 1:3 finished even & smooth without using extra cement complete all as specified and directed. |
| 9 | Material & Labour for preparation of new plastered surface of ceiling and applying three coat of white wash complete all as specified and directed. |
| 10 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed |
| 11 | Material & Labour for PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate), as in levelling course for sunken portion finished fair & even complete all as specified and directed |
| 12 | Material & Labour for Plain cement concrete 1:7:12 mix, type E-2 (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed. |
| 13 | Material & Labour for rendering 10mm thick on brick or concrete surface in Cement mortar 1:3 mixes with internal liquid water proofing compound as per manufacturers instructions, finishing surface even and smooth w/o using extra cement complete all as specified and directed.Note: Liquid WPC will be measured and paid separately under respective item of this schedule. |
| 14 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 15 | Material & Labour for 25mm thick, PCC 1:2:4, type B-0 (using 12.5mm graded stone aggregate), as in floor, sub base finished fair & even without using extra cement complete all as specified and directed. |
| 16 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 17 | Material & Labour for glazed coloured ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tiles laid/ fixed over and including 10 mm thick rendering in CM 1:4 complete all as specified and directed. |
| 18 | Material & Labour for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:4 complete all as specified and directed |
| 19 | Taking up or down steel tubing 15mm bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 20 | Taking up or down steel tubing 20mm bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 21 | Taking up or down steel tubing 40mm bore and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 22 | Supplying and laying CPVC pipes 20mm outer dia SDR 11 & Plain/brass CPVC SDR 11 fittings on walls/ceiling, laying in floor and or concealed in wall including for cutting chases in brick wall built in cement mortar, cutting n exc 10cm in width or girth and making good to match complete all as specified and directed. |
| 23 | S&F 15mm bore steel tubing galvanaised iron medium grade with all fittings and fixed to walls and ceiling or laid in floor including cutting chases in brickwall built in cement mortar, concealed in wall including cutting n exc 10cm in width or girth and making good to match complete all as specified and directed. |
| 24 | S&F tubing 20mm bore steel tubing galvanised iron medium grade with all fittings and fixed complete to walls and ceiling or laid in floor complete all as specified and directed. |
| 25 | Refixing 20mm bore GI steel water tubing medium grade fixed to walls complete all as specified and as directed. |
| 26 | S&F 40 mm bore steel tubing galvanised iron medium grade as spout complete all as specified and directed. |
| 27 | Taking down eaves, gutters and rain water pipes (any sizes or pattern) incl all fittings head, shoes, bend, swan neck etc incl cleaning for refixing or removing to store complete all as specified and directed. |
| 28 | S&F PVC(SWR) pipe, 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, fixed to walls with MS flat iron clamps of size 25 x 3mm, bolts, washers, nuts, nails etc, complete all as specified and directed.Note: flat iron clamps will be measured and paid separately in respected item. |
| 29 | Dismantling of cast iron pipes of 100 mm bore, jointed in cement mortar complete all as specified and directed. |
| 30 | Material and labour for laying 110mm dia UPVC soil, waste and vent pipes in any length with or without ears, with rubber ring joints using solvent as per manufacturers instruction ,fixed to wall with MS flat iron clamps and making necessary connections complete all as specified and directed.Note: flat iron clamps will be measured and paid separately in respected item. |
| 31 | Material and labour for providing and laying 110mm dia UPVC soil, waste and vent pipes in any length with or without ears, with rubber ring joints using solvent as per manufacturers instruction, laid in trenches or in floors and making necessary connections complete all as specified and directed. |
| 32 | S&F PVC (SWR) junction double, (double T), equal or unequal with access door for 110 mm bore complete all as specified and directed. |
| 33 | S&F PVC (SWR) junction single, (single T), equal or unequal with access door for 110 mm bore complete all as specified and directed. |
| 34 | S&F PVC(SWR) bends (any radius), for 110mm bore pipes, with access doors, complete all as specified and directed. |
| 35 | S&F for PVC cowl of 110mm dia complete all as specified and directed. |
| 36 | Excavation in trenches in soft/loose soil not exceeding 1.50 Mtr wide and not exceeding 1.50 Mtr in depth and getting out in soft/loose soil complete all as specified and directed. |
| 37 | M&L for cement concrete type D-2 1:4:8 (using 40mm graded stone aggregate) as bed to 100mm bore drain pipes including forming cradles complete all as specified and directed. |
| 38 | Returning and filling incl spreading, levelling, water and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 39 | Removal of excavated material n. exc 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and directed. |
| 40 | M&L for Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4section) in cement concrete 1:2:4 mix type B-1 smooth finished and reforming benching as required for 110mm bore pipe complete all as specified and directed. |
| 41 | S&F for mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 42 | S&F in repairs vitreous China Squatting pan 'Orrisa' pattern size 580x440mm white with integral foot rest and P or S trap, and jointing to PVC bend and flush pipe complete including making good to floor complete all as specified & directed. |
| 43 | S&F in repair Vitreous China wash down pedestal pattern EWC, white water closet pan with intergral trap including plastic water closet seat cover white closed pattern with flat bottom, and cover and mild steel chromium plated hinging device, making necessary connections to drain and to flushing pipe antisyphonage pipe etc, jointing to PVC and flush pipe including making good to floor complete all as specified and directed. |
| 44 | S&F in repair Concealed Stop Cock, fancy type, CP with long shank and cup, exposed part kit with wall flange, fitting sleeve, operating lever, adjustable wall flange and including regular brass body of concealed stop cock suitable for 15mm line with protection cap fixed in position complete in all respect all as specified. |
| 45 | Supply & fixed in repair brass chromium plated overhead shower rose 125mm dia with 250mm long stainless steel shower arm and incl all necessary accessories fixed to 15mm bore iron pipe or union complete all as specified and directed. |
| 46 | S&F in repairs vitereous china wash hand basin, white, flat back of size 550 x 400 mm with pedestal including, coupling, waste pipe, brackets, cutting for pinning in ends of brackets or erecting stand complete all as specified and directed. |
| 47 | S&F in repairs stop/angle Valve cast copper alloy chromium plated, fancy type screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 15mm bore dia iron pipe or for union complete all as specified and directed. |
| 48 | S&F in repairs stop/angle Valve cast copper alloy chromium plated, fancy type complete all as specified and directed., screwed down, high pressure, with crutch or butterfly handle, screwed both ends for 20mm bore dia iron pipe or for union complete all as specified and directed. |
| 49 | S&F in repair PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 50 | S&F in repair bib tap, cast copper alloy chromium plated fancy type with crutch or butterfly handle screwed for 15mm bore dia for iron pipe or for unions complete all as specifed and directed. |
| 51 | S&F in repair Brass CP mixer for WHB for mixing hot & cold water screwed down for 15 mm bore dia of iron pipe complete all as specified and directed. |
| 52 | S&F in repair brass chromium plated fancy type wall mixer assembly with L bend for shower, comprising of centre outlet tap, double inlet for hot and cold water with connecting legs and wall flange screwed for 15 mm bore dia iron pipe complete all as specified and as directed |
| 53 | M&L for PVC (SWR) floor/multi trap 110mm bore dia of outlet, with grating including jointing to waste pipe with solvent fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed. |
| 54 | S&F in repairs PVC valveless syphonic action type flushing cistern , low level white 10 Litres capacity with inlet, ball valve, float and handle complete all as specified and directed. |
| 55 | Dismantling of brick or terracing tiles of single layers on roofs and removed from site complete all as specified and as directed |
| 56 | Demolition of Mud in roofs, any thickness, including plastering and leeping (whether full thicknes removed or only a part thereof) and removing the demolished material out of MD land complete all as specified and directed. |
| 57 | M&L for wire brushing and cleaning top surface of RCC roof including flashings and junction of parapets, etc, complete all as specified and directed. |
| 58 | M&L for cement concrete 1:3:6 type C1 using 20 mm graded aggregate as in padding over roof minimum thickness at khurra as 25 mm to maintain a slope of 1:100 complete all as specified and directed. |
| 59 | M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) and applying bitumen 85/25 grade @1.20kg/sqm over 0.30 kg/sqm bitumen primer and landed APP membrane on primed surface by Torch application complete all as specified and directed. |
| 60 | M&L for Cement concrete tiles with grey cement and no pigment 25cm x 25cm x 22mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors over roofs including 15mm thick screed bed of CM 1:6 and filling the joints with cement mortar 1:3 complete all as specified and directed. |
| 61 | M&L for PCC 1:2:4, type B-0 using 12.5mm graded stone aggregate as in roof curve, benching, mud stops, steps, coping, hold fasts and the like items slightly rounded or chamfered on the edges complete all as specified and directed. |
| 62 | Taking down existing plaster from brick work or concrete surface and proper cleaning the surface with water and making for efforescence treatment by applying two coats of smart care damp proof coating and applying 15 mm thick plaster with CM 1:4 mixed with URP (301) over treated surfaces.Note : The complete item shall be got executed through the authorised applicator of manufacturer only and complete all as directed by Engr-in-charge. Applicator shall be got approval by GE before execution of work. |
| 63 | M&L for preparation of new plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new/treated surface complete all as specified and directed. |
| 64 | M&L preparation of newly plastered or unplastered surfaces of wall and applying two coat of OBD over a coat of primer complete all as specified and directed. |
| 65 | Disconnecting existing tanks of capacity exc. 250 but n exc. 500 litres, setting aside or lowering for cleaning etc and hoisting reconnecting and refixing in position complete all as specified and as directed |
| 66 | Disconnecting existing tanks of capacity exc.500 but n exc. 1000 litres, setting aside or lowering for cleaning etc and hoisting reconnecting and refixing in position complete all as specified and as directed |
| 67 | Dismantling water tank exc 250 & n ec. 500 Ltrs and removing to store complete all as specified and as directed. |
| 68 | Dismantling water tank exc 500 & n ec. 1000 Ltrs and removing to store complete all as specified and as directed. |
| 69 | S&F in repairs rotational moulded polythene, two layers, water storage tank 500 Ltrs capacity (ISI marked), white colour closed top, cylindrical, hoisted and fixed in position including dismantling of old tank complete all as specified and directed. |
| 70 | S&F in repairs rotational moulded polythene, two layers, water storage tank 1000 Ltrs capacity (ISI marked), white colour closed top, cylindrical, hoisted and fixed in position including dismantling of old tank complete all as specified and directed. |
| 71 | S&F ball brass valve, high pressure with polythene float and fly nut complete screwed for 20mm bore dia iron pipe or brass ferrule complete all as specified and directed. |
| 72 | S&F Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for 20mm bore dia iron pipe and fixed complete all as specified and directed. |
| 73 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.Note :- The rates incl scaffolding/ladders etc as required up to 12 m bldg height, not paid separatly. |
| 74 | S&F Framed work such as grills, cooler stands gratings, sunshade etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 75 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/sunshade etc, fixed with self tapping screws complete all as specified and directed. |
| 76 | Preparing new or previously untreated surfaces of steel and iron work of any description not otherwise described over 10cm width or girth and M&L for applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 77 | Preparing new or previously untreated surfaces of steel and iron work of any description not otherwise described width or girth not exc 10cm and M&L for applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 78 | Cutting chases in brick wall built in cement mortar,making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm in width or girth complete all as specified and directed. Please Enable Macros to View BoQ information |