| 1 | [10.30.1]Providing and laying of chequered precast cement concrete tiles 22 mm thick in footpath and courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). 1. Light shade pigment using white cement |
| 2 | [12.123]Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive. |
| 3 | [12.174]Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately). |
| 4 | [12.22.1]Providing and fixing plain lining with necessary screws/nuts and bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid separately). 1. 12mm thick commercial ply conforming to IS : 1328 BWR type |
| 5 | [12.4.4.2]Providing wood work in frames of false ceiling, partitions etc. sawn and fixed in position with necessary stainless steel screws etc. 4.2. Kiln seasoned and chemically treated Hollock wood |
| 6 | [13.30.2]Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 2. Hot finished seamless type tubes |
| 7 | [22.105.1]Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 1. 15 mm nominal bore |
| 8 | [22.34]Providing and fixing floor mounted, white vitreous chinaware single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous chinaware cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge. |
| 9 | [22.46]Providing and fixing white vitreous chinaware battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre and post flushing with water (250 ml and 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge. |
| 10 | [23.22.1.10]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.10. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 125 to 160 amp, 25 KA |
| 11 | [23.22.1.11]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.11. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 200 to 250 amp, 25 KA |
| 12 | [23.22.1.13]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.13. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 600 to 800 Amp , 50 KA |
| 13 | [23.22.1.9]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.9. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. 4 pole MCCB 6 amp to 100 amp , 25 KA |
| 14 | [23.22.2.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.2. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 250 A FP |
| 15 | [23.22.4.2]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.2. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 8 way ( 2 incoming and 6 outgoing) |
| 16 | [23.22.4.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.5. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 4 way ( 8 incoming and 3phase*4 outgoing) |
| 17 | [23.22.4.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.6. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 6 way ( 8 incoming 3phase*6 outgoing) |
| 18 | [23.22.4.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.7. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. TPN DB Horizontal type Double Door 8 way ( 8 incoming 3phase*8 outgoing) |
| 19 | [23.22.5.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.1. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 6 amp. to 32 amp Single Pole |
| 20 | [23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole |
| 21 | [23.22.5.6]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.6. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs TRIPLE POLE |
| 22 | [23.23.6..2]MISCELLANEOUS 6..2. Supply and erection of MS cable tray , duly pained as required including erection of the same on wall or ceiling with necessary fixture and other material required to complete the job in all respect up to the entire satisfaction of Engineer-in Charge of the work. MS perforated cable tray painted with powder coating 200 X 50 X 2 mm |
| 23 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required |
| 24 | [23.4.1.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 1.3. Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modular type face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C |
| 25 | [23.4.2.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 2.3. Wiring for Twin control light point with 2 nos , 2-ways, 5 amp. Modular switch GI box and modular face plate in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. Group C |
| 26 | [23.4.3.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 3.3. Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch Group C |
| 27 | [23.4.4.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 4.3. Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required Group C |
| 28 | [23.4.5.3]COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (SURFACE/RECESS) 5.3. Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling , including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required Group C |
| 29 | [23.5.6.1]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.1. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 1.50 Sqmm(1/1.40mm) |
| 30 | [23.5.6.2]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.2. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 2.50 Sqmm(1.1.80mm) |
| 31 | [23.5.6.3]COPPER WIRING IN EXISTING PVC/MS CONDUIT PIPE SURFACE/RECESSED FOR ELECTRICAL POINTS 6.3. Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required. 1 run of Size 4 Sqmm(1/2.24mm) |
| 32 | [23.7.6.4]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.4. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 40 mm dia. |
| 33 | [23.8.11.11]FITTING AND ACCESSORIES 11.11. Providing and fixing modular type accessories of approved make in existing box including fixing and making necessary connections, complete in all respect. RJ 45 Computer DATA socket outlet for CAT 6 or CAT6e cable Modular type |
| 34 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. |
| 35 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. |
| 36 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. |
| 37 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. |
| 38 | [24.2.7.5]LT CABLE 7.5. Supply and erection of suitable compression type brass cable glands for underground Cable :- 120 sqmm to 185 sqmm Cable 3 to 32 Core |
| 39 | [24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core |
| 40 | [24.2.8.7]LT CABLE 8.7. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 50 sqmm |
| 41 | [24.2.8.8]LT CABLE 8.8. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 70 sqmm |
| 42 | [24.2.8.9]LT CABLE 8.9. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 95 sqmm |
| 43 | [24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm |
| 44 | [6.1.1]Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work below plinth level and up to Floor IV level: 1. 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 45 | [6.30.3]Centering and shuttering including strutting, propping etc. and removal of form for 3. Suspended floors, roofs, landings, balconies and access platform |
| 46 | [6.33.3]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 3. Cold twisted bars |
| 47 | [9.30]Supply, fabrication and installation of self-supported arch shaped galvalume/ Zincalume steel sheet roofing 1.00 MM thick (BMT) (only ± 0.2mm tolerance allowed) and 1.075 MM thick (total thickness)(only ± 0.2mm tolerance allowed) tensile strength 350 MPa coating mass 150 gm per sqm etc. of approved make . The manufacturer shall follow the IS codes 15961, type III with Super Durable Polyester paint, IS code 513, IS code 16163 and all other relevant Indian codes as per approved specification, design and drawings of the corporation. |
| 48 | GI Sheet Metal Rectangular and Round Type Duct (Factory/Site Fabricated):Make:- Tata / Sail / Jindal / JSWSupply, installation and testing of site fabricated sheet metal ducts of following thicknesses including necessary supports, flexible hangers with isolators, nut bolts, gasket, splitter dampers and vanes etc. complete as per specification approved shop drawings .24 Gauge |
| 49 | GI Sheet Metal Rectangular and Round Type Duct (Factory/Site Fabricated):Make:- Tata / Sail / Jindal / JSWSupply, installation and testing of site fabricated sheet metal ducts of following thicknesses including necessary supports, flexible hangers with isolators, nut bolts, gasket, splitter dampers and vanes etc. complete as per specification approved shop drawings .22 Gauge |
| 50 | Indoor UnitsSupply, Installation, Testing and Commissioning of VRF indoor units with factory fitted electronic expansion valve, multi speed fan motors, dynamically balanced blowers, synthetic washable plasma media filter with hydrophobic coating on cooling coil. Electronic components like PCBs must be essentially enclosed in a metal box compartment being integrated part of indoor unit to ensure enhanced fire protection with auto by pass technology allowing uninterupted operation of indoor units connected to a circuit in event of break down in any indoor connected to same circuit. All indoor units shall have individual fan speed and temperature control mechanism to be operated from corded/cordless remote. In addition to all indoor units can also be operated from central remote control. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required)All Ducted Units must have drain pump for lifting the condensate water.Twinning Kits |
| 51 | Operation and mtc of electrical low voltage system complete in all respect to entire satisfaction of EIC |
| 52 | Operation and mtc of electrical system complete in all respect to entire satisfaction of EIC |
| 53 | Providing and applying PU/ glossy finish Polish as per approved shed including prepareation of base PU material all complete as per E.I.C |
| 54 | Providing and fixing decorative high pressure laminated sheet of plain wood grain in gloss/matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS:2046 type S including cost of adhesive of approved quality |
| 55 | Providing and fixing of 12mm thick toughed glass of approved brand and maufactured fixed in window ventilators and partition etc including providing sealant (both primary and secondary sealant) etc as per specifications drawings and direction of EIC complete |
| 56 | Providing and fixing of glass film/ frosted/ lining/ shade on 10mm/ 12mm Toughened Glass door and window complete in all respect as per E.I.C |
| 57 | Providing and fixing of lining with necessary screws/nuts and bolts/nails, including a coat of approved primer on one face, and fixed on wooden/steel frame work complete as per direction of EIC (frame work shall be paid separately) HDHMR |
| 58 | Providing and fixing of Loovers Door for Electrical Duct complee in all respect as per E.I.C (Made of Flush Door and Margens) |
| 59 | Providing and fixing of Teak ply 4mm thick with carriage, labour etc complete in all respect |
| 60 | Providing and fixing of Wooden blinds on windows complete with material and labour complete with push up and down arrangement as per approved design / colour and Engineer-in-charge. |
| 61 | Providing and fixing of wooden teak hand rail for stair case and labour carriage etc complete in all respect. |
| 62 | Providing and fixing plain lining with necessary screws/nuts and bolts/ nails, including a coat of approved primer on one face, and fixed on wooden /steel frame work, complete as per direction of Engineer-in- charge (Frame work shall be paid separately). 1 19mm thick commercial ply conforming to IS : 1328 BWR type |
| 63 | Providing and fixing wooden moulded corner beading of triangular shape to the junction of panelling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete Teak wood Moulding 1 50x50 mm (base and height) |
| 64 | Providing and laying Polished Granite stone flooring in required design and patterns, in linearas well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.1 Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. (Leather Finished Grenite) |
| 65 | Supply and erection of suitable for g eneral lifhting recessed Linear 40 Watt sutable for general lighting Luminaire should have die cast sink with polycarbonate diffuser. The luinaire should have CRI 80 and CCT pf 4000 K. The luminarie shall be complaint with IP20 classification. The fixture should have a minimum system efficacy of 100 lumen/watt and a minimus system lumen output of Min. 2800 lumens and maximum lumen depreciatin of upto 30% over 50K buring hours@design ambient temp 45 deg C. complete in all respect as approved and disired by the Enginer-In-Charge at site Make Bajaj |
| 66 | Supply and fixing of Rigid uPVC medium class Piping complete with fittings,supports and duly insulated with 10 mm closed cell nitrile rubber insulation as per specifications.Make:- Supreme / Finolex / Ashirwad32 mm Dia. |
| 67 | Supply Installation Testing and Commissioning of Commercial LED 55-Inch 4K (3840x2160) Resolution Connectivity: 3 x HDMI , 2 x USB, Headphone with wall mount stand and HDMI cable complete in all respect as approved by the Engineer-in-charge at site. |
| 68 | Supply, installation and commisioning of HDMI cable 10 mtr complete in all respect to the entire satisfaction of E.I.C |
| 69 | Supply, installation, testing and commisiong of 1 HP submersible pump starter and sensor |
| 70 | Supply, Installation, Testing and Commisioning of HI Wall split units with 5 Star rting with factory fitted electronic expension valve, multi speed fan motors, dunamically balanced blowers, synthetic washable plasma media filter with hydrophobic coating on cooling coil. Electronic components like PCBs must be essentially enclosed in a metal box compartent being integrated part of indoot unit to ensure enhanced fire protection. Outdoor unit equiped with PCBs accumulator, oil seperator, burshless DC inverter fan mo tor, OEM self manufactured hermetic sealed multi valve scroll type compressor. Heat exhanger ust be essentailly equiped with internally grooved copper tubes for better hear exchange performacne and operate in extremen condition i.e even at ambient temparatue of 52`C |
| 71 | Supply, Installation, Testing and Commissioning of 20 KVA online UPS with 1 hour back up. UPS shall be both Tower as well as Rack convertible, UPS shall be with Unity output Load PF i.e. kVA = kW. UPS shall be Three Phase In and Three Phase Out. The same UPS also shall be capable to operate with configuring as, 3 Phase Input and 1 Phase Output and 1 Phase Input and 1 Phase Output. The UPS shall be double conversion online topology designed to protect electronic equipment by supplying reliable, network-grade power featuring extremely tight voltage and frequency regulation.The UPS shall be with input power factor correction (PFC). The UPS contains a battery charger, which operates from the DC bus. For future enhancement, It shall be possible to parallel minimum 4 number of UPS. Common Battery Bank for parallel UPS up-to 4 numbers shall also be available. It shall be possible to connect Hot Swappable Batteries (Rack Mount Pluggable batteries) with the UPS. Battery VAH should be 28800 VAH. UPS Technology and Capability True Online configuration with double conversion VFI SS 111, Microprocessor /DSP based control, using IGBT devices and high switching frequency PWM ()15kHz), Active Power Factor Correction (APFC) in converter to improve Input Power Factor ) 0.95. Input facility -Phases / Wires 3 Phase IN and 3 Phase Out. The same UPS shall be capable for 3 IN:1OUT and 1IN:1 OUT as well.Input Voltage Range 280– 490 V AC (L-L) @ Full Load. Input Power Factor ) 0.95 on Full Load. Nominal Output voltage 380/ 400/ 415 VAC (Selectable) AND 220/ 230/ 240 VAC (Selectable). Non Essential Load Disconnect Capability Circuit Breaker shall be available on the UPS Module which can disconnect non-essential loads up-to 16Amps during the overloading condition. Nominal Output Frequency 50 / 60 Hz. Out Wave Form Pure sine wave. Overall Efficiency (AC to AC) - Online (Double Conversion) Up-to 96%. Green Mode / Eco Mode Shall be provided. Indications (LED/LED) AC indicator/Battery Mode of Operation / Bypass feeding the load / UPS Fault. Emergency Power Off Should be provided as standard in the UPS. NMC Web Enabled NMC Card shall be provided with each UPS to monitor and manage the UPS in TCP/IP network environments and shall be capable of gracefully shutting down one or more operating systems during the time when the UPS is in on-battery mode., Shall also able to support/Shutdown Linux Server and VMWare Machine ESXi support., IPv6 Support shall be available, BACnet/IP and Modbus TCP Support, Possible to add Temperature Sensor / humidity sensor to NMC Card and Aux Dry Contact’s as well.Input Phase Sequence Corrector should be provided. Product Certificates IEC62040-1,2, CE. Complete in all respect to the entire satisfaction of the engineer-in-charge. |
| 72 | Supply, Installation, Testing and Commissioning of Digital Audio Amplifier. Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of 100 W at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall (be Wall/Panel Mounted) not be rail mounted / dependant on Fire Panel CPU for operation. Failure of Fire Panel CPU shall not result in failure of Amplifier operation. The Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem and for the best sound intelligibility. All amplifiers shall provide back up of minimum 5 hours using secondary power source(battery power/UPS power) Complete in all respect to the entire satisfaction of the engineer-in-charge . |
| 73 | Supply, installation, testing and commissioning of Intel (R) core i7 13700 CPU @ 2.10GHz (20 CPUs) 2.1 GHz 32 GB RAM, graphic card model is NVIDIA RTX A4000 or equivalent |
| 74 | Supply, Installation, Testing and Commissioning of VRF indoor units with factory fitted electronic expansion valve, multi speed fan motors, dynamically balanced blowers, synthetic washable plasma media filter with hydrophobic coating on cooling coil. Electronic components like PCBs must be essentially enclosed in a metal box compartment being integrated part of indoor unit to ensure enhanced fire protection with auto by pass technology allowing uninterupted operation of indoor units connected to a circuit in event of break down in any indoor connected to same circuit. All indoor units shall have individual fan speed and temperature control mechanism to be operated from corded/cordless remote. In addition to all indoor units can also be operated from central remote control. (All Unit shall confirm the detailed specification of tender document and providing power/ control cabling/earthing of indoor unit complete with supplying of all material in all respect as per specifications and any other items required to make the system complete as required)All Ducted Units must have drain pump for lifting the condensate water.T/Y- Joints |
| 75 | Supplying and fixing of following thickness duly laminated aluminum foil of mat finish Closed Cell Nitrile Rubber (class 1) insulation on existing duct after applying two coats of cold setting adhesive. The joints shall sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications.13 mm thick insulation. |
| 76 | Supplying and Installation of interconnecting following size of refrigerant copper pipe with required all fitting duly insulated with XLPE insulation as per tender specification between each set of indoor and outdoor units as per specification all piping inside the room shall be properly supported with M.S. Hanger.Make:- Ref. Pipe:-Total Line/ Rajco / Mexflow / RR, Insulation:- Supreme/ Armacel / K-Flex / A-Flex22.2 mm O.D. (Insulation 19mm) |
| 77 | Supplying and Installation of interconnecting following size of refrigerant copper pipe with required all fitting duly insulated with XLPE insulation as per tender specification between each set of indoor and outdoor units as per specification all piping inside the room shall be properly supported with M.S. Hanger.Make:- Ref. Pipe:-Total Line/ Rajco / Mexflow / RR, Insulation:- Supreme/ Armacel / K-Flex / A-Flex34.9 mm O.D. (Insulation 19mm) |
| 78 | Supplying and Installation of interconnecting following size of refrigerant copper pipe with required all fitting duly insulated with XLPE insulation as per tender specification between each set of indoor and outdoor units as per specification all piping inside the room shall be properly supported with M.S. Hanger.Make:- Ref. Pipe:-Total Line/ Rajco / Mexflow / RR, Insulation:- Supreme/ Armacel / K-Flex / A-Flex41.3 mm O.D. (Insulation 19mm) |
| 79 | Supplying and Installation of interconnecting following size of refrigerant copper pipe with required all fitting duly insulated with XLPE insulation as per tender specification between each set of indoor and outdoor units as per specification all piping inside the room shall be properly supported with M.S. Hanger.Make:- Ref. Pipe:-Total Line/ Rajco / Mexflow / RR, Insulation:- Supreme/ Armacel / K-Flex / A-Flex28.6 mm O.D.(Insulation 19mm) Please Enable Macros to View BoQ information |