| 1 | White washing with lime on undecorated wall surfaces (Three or more coats) to give an even shade including thoroughly brooming the surface to remove all dirt, dust mortar drop and loose scales of lime wash and other foreign matter.(CHAPTER- 16 Si.No.13.37 New) |
| 2 | Class-150 Brick Work in 1:4 Cement and Coarse Sand, mortar in foundation and plinth including supply of all materials, labor and tools and plants, etc. Required for proper completion of the work. ( Chapter No. 06 Sr.No. 2) |
| 3 | Dismentling Existing damage Plaster Including disposal of refuse as directed by E/IC with in a distance of 60 meters etc. all complete. {Chapter No. 17 S.I. No.16 (706)} |
| 4 | 12mm thick cement plaster in single coat of fair side of single of half brick wall for interior plastering up to floor two level including internal rounded angles chamfers and rounded angles not excluding 80mm in girth and finished even and smooth. No extra for mixing any additive.(c) 1 Cement : 4 Coarse sand.(Chapter No.13 Si.No.582(ii)) |
| 5 | Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. supply of all labour material and T&P required for proper completion of work. |
| 6 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 328 ll lo sqm) over and including priming coat of exterior primer applied @ 2.20k9/10 sqm supply of all labour material and T&P required for proper completionof work |
| 7 | Finishing walls with Acrylic Smooth exterior paint of required shade: New work (Two or more coat applied @ 1.67 Itr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) supply of all labour material and T&P required for proper completion of work. (Chapter No.15 Si.No.5) |
| 8 | PLAIN GLASS (Best Quality, Cut to Size) 5mm thick |
| 9 | Providing and laying D.P.C. 40cm. Thick with cement concrete consisting of one part cement 1.5 part of coarse sand and three part of approved 10mm grade stone grit and including water proofing material as directed by the engineer-in-charge in the proportion as specified by the manufacturer. {Chapter No.07 Si.No.361} |
| 10 | Paint of the two coat over priming coat including cost of priming coat new steel gril etc. all complete.(15-Chapter Sr.No.1a+2a+642) |
| 11 | Providing and Fixing PVC pipe conforming to ISI make working pressure 6 kg/Cm including testing labour T&P etc. all complete.110mm diameter. (Chapter No.23 SI.No. 32(iii)) |
| 12 | Providing and laying Cement Concrete in 1:2:4 of not less than strength of M-15 stone grit (20 mm nominal size) approved coarse sand and cement. Curing complete including of cost of form work in foundation and floors.(5-Chapter Sr.No.6 Si.No..4.1.3) |
| 13 | RCC work Providing and laying in position specified grade of reinforced cement concrete,Slab including the cost of centering, shutterang, finishing and excluding reinforcement - Above plinth level upto fifth floor lable : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone |
| 14 | Mild steel or iron in plain work such as reinforced concrete or reinforced brick work (when not included in and an overall rates) brought for proper completion of the work and including supply of steel, its wastage bend hooks and authorized over lapping shall be measured up to floor two level. (b) 10mm to 12mm tor.(Chapter No. 10 S.I. No. 504(B)) |
| 15 | Providing and Applying water proofing coating system over horizontal and verticle surface on roof by carrying out:1) Single coat of efflorescence resistant penetrating primer (Primeseal of Dr. fixit or equivalent) over cleaned roof surface to provide priming surface2) Single coat of heavy duty reinforced trafficable water proofing coating compound (New Coat of Dr. fixit or equivalent) over priming surface to give base course,3) 45 gsm glass fiber mesh evenly over the base course to make the waterproofing system foot trafficable4) Two coats of heavy duty reinforced trafficable water proofing coating compound (New Coat of Dr. fixit or equivalent) over fiber mesh to give wearing/finished course. The cost of this work includes cost of providing and applying of priming coat, fiber mesh and 3 coats of water proofing compound including finishes, Air curing. 07 days ponding, etc. complete as per manufacturer's specification and instruction of Engineering In Charge. (MR) |
| 16 | Applying of micro-concrete over terrace of 50-75mm thick over three layered waterproofing 1x1 with mesh. (MR) |
| 17 | Providing and fixing lSl marked flush door shutters conforming to lS : 2202 (Part l) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.including ISI marked Stainless Steel butt hinges with necessary screws. (A) 35mm Thick. (Excluding cost of Flttings) (Chapter No.9 Si.No.1-9.21.1) |
| 18 | Supply and Fixing Oxided Iron Fitting etc. all complete (None Scheduled) |
| 19 | Paint of the two coat over primer coat wood surface and etc. all complete.(15-Chapter Si.No.8+10+11) |
| 20 | Fixing Door chowkhats in existing opening including embedding chowkhats in floors or walls cutting masonry for holdfasts, embedding hold fasts in cement concrete blocks of size 15x10x10 cm with cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size), painting two coats of approved wood preservative to sides of chowkhats and making good the damages to walls and floors as required complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in- Charge. (Chapter No.9 Si.No.7a-14.2.1) |
| 21 | Mild steel of iron in heavy size such as trusses built up gates record reck, roof work gates etc. brought to required form including drilling holes revitting are welding where neccesary, and also including supply of steel bolts , nuts wastage etc. and there fixing required for completion of the work. (Chapter No.10 Sr.No.2) |
| 22 | Cleaning of the site for warkable etc. All complete. (Non Scheduled) |
| 23 | Earth work in Excavation in foundation in ordinary soil (loam, clay or sand) including, lift up to 1.50 m and lead up to 30m and including filling watering and ramming of excavated the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge up to a distance of 30 M form the foundation trenches. (Rate including Royalty of earth also) (4-Chapter Si.No.1) |
| 24 | Cartage of Malva, Silt, sludge kankar and other disposable organic material etc. all complete with labour T&P including cartage of 8 km. (Chapter No.3 Si.No.8) |
| 25 | Providing and laying D.P.C. 40cm. Thick with cement concrete consisting of one part cement 1.5 part of coarse sand and three part of approved 10mm grade stone grit and including water proofing material as directed by the engineer-in-charge in the proportion as specified by the manufacturer. {Chapter No.07 Si.No.361} |
| 26 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40mm dia steel pulleys, Complete with bolts, nuts, locking arrangement, stoppers, handles, including apptying a priming coat of approved steel primer.(Chapter No.10 Si.No.4-10.3) |
| 27 | Supply and fixing 6mm (1/4\\") thick Chine white glazed tiles in flooring or dado laid with 1:3 cement and approved coarse sand mortar and approved coarse sand mortar finished with white cement jointed and polishing complete including supply of all materials, labor for porper completion of the work. (Chapter No.14 S.I. No. 628) |
| 28 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100mm Sand Cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the wall and floors wherever required : White Vitreous China Orissa pattern W.C. pan of size 580x440 mm with with integral type foot rests. (Chapter No.24 SI. No.1) |
| 29 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standared size C.P. brass flush pipe, spreaders with union and clamps (all in C.P. brass) with waste fitting as per IS: 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fitting and cutting and making good thg walls and floors whereever required: Single half stall urinal with 5 litre PVC. Automatic flushing cistern. (Chapter No.24 Si.No.6A) |
| 30 | Providing and fixing wash basin with C.l. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets,cutting and making good the walls wherever require: (White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C. P. brass pillar taps) {Chapter No.24 Si.No.5A} |
| 31 | Providlng and laying Polished Granite Jet Black stone flooring in req0ired design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.{Chapter No.14 Si.No.27} |
| 32 | Providing and Fixing PVC pipe conforming to ISI make working pressure 6 kg/Cm including testing labour T&P etc. all complete.110mm diameter. (Chapter No.23 SI.No. 32(iii)) |
| 33 | Providing and Fixing PVC pipe conforming to ISI make working pressure 6 kg/Cm including testing labour T&P etc. all complete.140mm diameter. (Chapter No.23 SI.No. 32(iv)) |
| 34 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & Cold Water Supply, including all CPVC Plain & brass threaded fittings I/c fixing the pipe with clamps at 1.00 m spacing, This includes Jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints, complete as per direction of Engineer-in-Charge. Concealed work, of including cutting chases and making good the wall etc.(d) 32mm nominal outer dia pipes. (Chapter No.23 Si.No.2D) |
| 35 | Providing and Fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & Cold Water Supply, including all CPVC Plain & brass threaded fittings I/c fixing the pipe with clamps at 1.00 m spacing, This includes Jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints, complete as per direction of Engineer-in-Charge. Concealed work, of including cutting chases and making good the wall etc.(d) 15mm nominal outer dia pipes. (Chapter No.23 Si.No.2A) |
| 36 | Supply & Fixing of brass Bib Cock of approve quality etc. all complete. (Chapter No.21 Si.No.43) |
| 37 | Supply & Fixing of C.P. brass Stop Cock (Conceled) of Standerd design of approve quality etc. all complete. (Chapter No.21 Si.No.44) |
| 38 | Providing & Fixing 1st quality ceramic glazed floor tiles conforming to lS : 15622 (thickness to be specified by the manufacturer )of approved make in atl colours, shades except burgundy, bottle green, black of any size as approved by Engineer-inCharge in skirting, risers of steps and dados over '12 mm thick bed of cement Morta|l:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 33kg per sqm including pointing in white cement mixed with pigment of matching shade comPlete. |
| 39 | Providing and Laying Vitrified Tiles 500x500mm Size (thickness 10mm), with water absorption less than 0.08% and conforming to IS:15622, of approved brand manufacture, in desired colours and shades, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, including grouting of joints. Including 75mm thick base with concrte 1:4:8 complete as per E/I etc. all complete. (Chapter No.14 Sr.No.20) |
| 40 | Supply and Fixing of Light Fitting Switch Board. (None Sheduled) |
| 41 | Supply and Fixing Wiring of Light Point. (None Sheduled) |
| 42 | S/L/J of 20mm dia PVC Cunduct Pipe etc. all complete. |
| 43 | Supply & Fixing of wiring Sub Main. |
| 44 | Supply & Fixing of Plug Point 15mm. |
| 45 | Lettering & Painting of wall etc. all complete. |
| 46 | Supply & Fixing of 27watt. CFL etc. all complete. |
| 47 | Kota stone slab flooring over 20 mm (average) thick base laid over and joined with gray cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1:4 (1 cement: 4 coarse sand) :25 mm thick. (Chapter No.14 Si.No.12-11.26.1) |
| 48 | 6mm thick Celling plaster 1:3 (1 cement :3 fine sand) cement & fine sand in F.M not less than 1.25, 1:3 including chipping of RCC surface before celing plaster. The cost of including at material, labor T&P and scafolding etc complete. (Chapter No.13 Si.No.13) |
| 49 | Paint of the two coat over priming coat including cost of priming coat on steel work etc all complete.{15-Chapter Sr.No.9+10+11} |
| 50 | Rectangular shape 1500x450 mm Mirror with Plastic moulded frame. (Chapter No.22 SI.No.77) |
| 51 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam (22.40-53mm) specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. |
| 52 | Supply & Laying of I shaped (Zigzag) precast lnterlocking tiles of thickness 60 to 100mm (Compressive strength not less then 30Mpa and weight 4.50k9) lncluding 0.30mm thick local sand base levelling and dressing of surface to required level and slope, filling joints with local sand all complete work. 80 mm (Rubber molded Coloured) |
| 53 | Sub Total (A) |
| 54 | Add / Deduction For Estimate Figure Amount Match |
| 55 | Grand Total Please Enable Macros to View BoQ information |