|
| 1 | WATERPROOFING TREATMENT TO RCC RETAINING WALL/RCC SLAB/TERRACE WITH BRICK TILE SURFACE AREA FROM EXTERNAL SIDE USING LIQUID APPLIED SINGLE COMPONENT POLYURETHANE COATING Providing and applying waterproofing treatment to RCC retaining walls/RCC slabs/ Terraces with brick tile surface with using liquid applied single component flexible polyurethane coating in two coats at coverage rate of 1.6kg/sqm including one coat of primer @ 250grm/sqm with following properties:1) Elongation : 300-400%2) Solid Content : > 70% by weight 3) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 4) Adhesion strength : > 1.03N/mm2 The work includes the Cleaning of the RCC slab/terrace brick tile surface/ RCC wall for treatment by removing dust, dirt and layers of concrete deposited over the surface. etc. by mechanical tools and wire brushing. Repair of construction joints or honeycombs with non shrink cementations grout by mixing shrinkage compensating admixture per bag of cement as per manufacturer’s recommendations. Providing and applying liquid applied single component polyurethane coating in 2 coats over priming coat as per mentioned details. The cost also includes providing and laying of fiber mesh as reinforcement to the coating i/c all wastages (Make : Sikka/BASF/Fosroc) |
| 2 | GRC Shikhar For Lord Ganesh & Lord Bherav Temple (6mtr Height) Providing of Glass Reinforced Concrete (GRC ) elements in Approved size, Pattern, Design, standerd thickness design elements is 25-30 mm, thick have weight approximately between 3-4 kg per sqft, The GRC should be made from '53 Grade' white Portland cement manufactured by \\"JK Cement\\" or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by made in JAPAN (Nepon) or equivalant, Super Plasticizers manufactured by BASF\\" or equivalent, Polymers manufactured by 'BASF' or equivalent. The material casting should take place in Synthetic Rubber/FRP Mould. Shikhar for Lord Ganesh & Lord Bherav Temple (6mtr Height) |
| 3 | GRC Shikhar For Lord Ganesh & Lord Bherav Temple (3.50 mtr Height) Providing of Glass Reinforced Concrete (GRC ) elements in Approved size, Pattern, Design, standerd thickness design elements is 25-30 mm, thick have weight approximately between 3-4 kg per sqft, The GRC should be made from '53 Grade' white Portland cement manufactured by \\"JK Cement\\" or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by made in JAPAN (Nepon) or equivalant, Super Plasticizers manufactured by BASF\\" or equivalent, Polymers manufactured by 'BASF' or equivalent. The material casting should take place in Synthetic Rubber/FRP Mould. Shikhar for Lord Ganesh & Lord Bherav Temple (3.50 mtr Height) |
| 4 | Lime plaster & Design Work/Heritage Restoration of Main Shikhar of Mata Raj Rajeshwari temple Detailed restoration including surface repairing and PU coating finish work Main Shikhar of Mata Raj Rajeshwari temple complete in all respect as per direction of engineer incharge. |
| 5 | Providing, making and placing of statues as per direction of engineer in chargeGanesha ji (Sand Stone) Size 5*3*1.5' |
| 6 | Bhairava ji (Granite Stone) Size 6*3*1.5' |
| 7 | Shiv ji parivar (Granite Stone) Size 5*4*2' |
| 8 | Sphatic shivling (Granite Base) Size 4*4*2' |
| 9 | Hanuman ji (Sand Stone) Size 6*2*1.3' |
| 10 | Surya dev ji (Granite Stone) Size 6*3*1.5' |
| 11 | Nandi Maharaj Ji ( Granite Stone) Size 1.5*2*1' |
| 12 | Bird house specifications as per engineer in charge and as per architectectural drawings issued by design cell (10*10*65') |
| 13 | Providing and fixing of 12mm toughened glass for glass house specifications as per engineer in charge and as per architectectural drawings issued by design cell (Any type of hardware is excluded) |
| 14 | Providing and fixing in position panelling with 12mm thick Bison panel board over existing MS frame section with the help of self tapping screws incuding all wastage, hardware, Scaffolding etc |
| 15 | Providing and filling 10mm wide movement joint in marble/granite flooring with backer road and PU sealant filling as per specification by manufacturer |
| 16 | Providing and fixing of expansion joint system for floor/wall/ceiling joints. The joint system shall consist of extruded aluminium base members, self-aligning/self-centering arrangement and support plates etc. The system shall be such that it provide floor-to-floor, floor-to-wall expansion control for various vertical locations and accommodate multi-directional seismic movement without stress to its components. The cover plate shall be designed for required width with 2 mm thickness. The complete system will include provision of Moisture Barrier Membrane in the joint system to have watertight joint is mandatory requirement all as per the manufacturer's design and as approved by Engineer-in-Charge. Floor joint suitable for a 75 mm gap. |
| 17 | construction of ornamental arch for span of 3100mm and height upto 4000mm as per architect drawing and as desired by Engineer in charge (Painting and stone work etc will be covered in respective items and paid separately. Please Enable Macros to View BoQ information |