| 1 | Works Details |
| 2 | [23.23.9]MISCELLANEOUS 9. Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required [Through Rate] |
| 3 | [23.33.1 (a).1]Online UPS - Input supply: Single Phase, Output Supply : Single PhaseSupplying, installation, Testing and Commissioning of following capacity at full load (Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input, Single Phase output AC Supply. The UPS shall include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated Gate Bipolar Transistor (IGBT)`s both for the rectifier and inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be )95% at 100% non-linear loads. Current total harmonic distortion (ITHD)/ total demand distortion (TDD) on the input grid shall be ( 5% at 100 %load. (The required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for incoming supply AC single phase 160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz plus /- 0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute.Operating temperature 0 to 40 deg C, Relative humidity 0-95% non condensing, noise level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current, short circuit, battery deep discharge, 10 KV surge. Display for watt/VA, Amp and Voltage power parameters etc. UPS shall comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS (as per standard IEC 62040-1, 2 and 3). The UPS should be with IGBT Based Inverter Technology, Communication RS232/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor cable of suitable size and connectors and all required accoseries are inclusive in the cost. The UPS should have QR code which should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc 1. 2KVA [Rate] |
| 4 | [23.7.6.2]PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. [Through Rate] |
| 5 | SITC of UTP Cat-6 information outlet Make and Model: RandM/Dlink/Molex or equivalent |
| 6 | SITC of Face plate (Single / Dual) Make and Model: RandM/Dlink/Molex or equivalent |
| 7 | SITC of UTP cat 6 Mounting 3 Feet length Patch Cords Low smoke zero halogen (LSZH/LS0H )complete in all respect upto the entire satisfaction of Engineer-in-Charge of the work. Make : Dlink / Molex / RandM or equivalent |
| 8 | SITC of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end. Make : Dlink / Molex / RandM or equivalent |
| 9 | SITC of POE 24 Port 10/100/1000 Base-T Switch should have 24 x Gigabit Base T Port and 4 x SFP Port. SFP Should be from the same OEM.Support PoE Standards - IEEE 802.3af and IEEE 802.3at Switch should support 16k Mac address Switching Capacity of 52 Gb or better ,Should support 12kb jumbo frame Should support upto 1000 multicast groups Security based on 802.1x, MAC Filtering, Guest VLAN, Broadcast storm recovery SNMP V1,V2, Web GUI, Dual memory for working and backup, LLDP, Spanning Tree, port Mirroring, Flow control should support zero touch provisioning Should support IPv4 and IPv6 static routes and interfaces SNTP v4, Syslog, Link Aggregation`0°C to plus 45°C EN 55022, EN55024, EN60950-1, EN50082-1, IEC 60825-1, IEC 60825-2 Vendor should be present in Gartner Magic Quadrant. inlcuding cost of all material and labour required to complete the job in all respect upto the entire satisfaction of Engineer -in-charge of the work. All Switches should be from same OEM. Make: Alcatel Lucent / Cisco / Allied Telesis or equivalent |
| 10 | SITC of 24 port Core Switch (L3 switch) with 24x10G 1000 Base-T ports and 2x10G SFP plus and 2 x 40G/100G QSFP28 slots with minimum switching capacity of 920 Gbps and forwarding rate: 684 mpps, 8 GB RAM, 32GB Flash and 32 mb packet buffer, should support stacking up to 6 switches with stacking bandwidth of 160Gbps. It should have internal single Power Supply, AC voltage: 90 to 260V (auto-ranging), IPv6 logo ready, Tri-authentication: MAC-based, web-based and IEEE 802.1x, Access Control Lists (ACLs) based on layer 3 and 4 headers, EPSRing (Ethernet Protection Switched Rings) with SuperLoop Protection (SLP) or equivalent, Static Routing, RIPv2, OSPFv2, BGP, MP-BGP, VxLAN, IS-IS, DVMRP, VRF, BFD, RoCEv2, OVSDB, In-Service Software Upgrade (ISSU), Built-in CPU protection against malicious attacks, Latency: ( 4 µs, EAL2/NDcPP, TEC certification and Zero trust architecture complaint with all required licenses to be supplied from day and enhanced recovery for extra resiliency, Switch should be EU RoHS compliant, .Operating temperature range: 0°C to 45°C (32°F to 113°F) Derated by 1°C per 305 meters (1,000 ft), Certification: UL, cUL, TUV, FIPS 140-2 , Stacking cables and associated accessories will be provided with switch complete etc. as required Make: Alcatel Lucent / Cisco / Allied Telesis or equivalent |
| 11 | SITC of Layer -2 Switch with Power on Ethernet (PoE) enabled, with 8 nos. 10/100/1000 base Tx PoE port, 2 no. dual personality Gbe Port for copper/fiber uplink loaded with fibre module as required, 3.7 Gbps switching capacity, 2.7 MPPS forwarding rate, maximum power consumption 135 watt. Make Alcatel Lucent / Cisco / Allied Telesis or equivalent |
| 12 | SITC of Wall mounted 9U enclosure of dimension600W X9UX500D with front sheet steel glass door, top and bottom cCover with cable entryprovision, integrated side walls,1 pair of 19` angles with wall mounting provision, captivehardware(pack of 20) complete in all respect upto entire satisfaction Engineer in charge ofworks. Make COMRACK/Dlink/HN or equivalent. |
| 13 | SITC of PVC Cable Manager finger duct type complete the job in all respect upto the entire satisfaction of Engineer-in-charge of work. Make : Legrand / Corning /Comrack or equivalent |
| 14 | SITC of 3 Core Power Cable 1.5 sqmm. complete in all respect upto the entire satisfaction of Engineer-in-charge of work Make: Finolex / Polycab / Havells or equivalent |
| 15 | SITC of IP Based voice Communication System with 08 Port Voicemail ,04 Port FXS ,04 Port FXO Circuit with CLIP Facility, 116 IP users License ,02 Each IP based Operator Console, 30 Party Conference ,Speed Dial, Music on Hold , Internal/ External ring difference ,Call Barring, Call Pickup Expandable 500 User .Approved Makes: Matrix /Alcatel/ Seimens (MR) or equivalent |
| 16 | SITC of Type 2 IP Phone with 2 Voip accounts, 2 Lines , HD Voice,Graphic LCD display with backligh. Approved Makes: Matrix /Alcatel/ Seimens (MR) or equivalent |
| 17 | SITC of 27RU, 600w x 800d, 19` Comms equipment rack with front I9` rails and dual 8 to 12-outlet PDUs, and mesh-Screen front and rear lockable doors, ventilated top cover with cable glandsMake Comrack/Dyamnic/Dlink or equivalent. |
| 18 | SITC of Gang Box PVC 2x2 Make Dlink/Molex/RandM |
| 19 | Deduct - Buy back cost of old EPABX system and all allied items (L/S). Please Enable Macros to View BoQ information |