| 1 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (a) 75 mm diameter |
| 2 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (a) 110 mm diameter |
| 3 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (a) Coupler 1242.1.2 110 mm diameter |
| 4 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.(a) Coupler12.421.1 75 mm diameter |
| 5 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382,leaving 10 mm gap for thermal expansion. (a) Single tee with door 75x75x75 mm |
| 6 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (a) Single Y Junction 75x75x75mm |
| 7 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. (a) Duoble Y Junction 110x110x110mm |
| 8 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.Bend 87.5° (a) 110 mm bend |
| 9 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.(a) 12.42.51 75 mm bend |
| 10 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc. Internal work - Exposed on wall (a) 50 mm dia nominal bore |
| 11 | Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc.Internal work - Exposed on wall (a) 65 mm dia nominal bore |
| 12 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : (a) 50 to 80 mm nominal bore |
| 13 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : (a) 50 mm nominal bore |
| 14 | Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : (a) 65 mm nominal bore |
| 15 | Providing and fixing gun metal gate valve with C.I. wheel of approvedquality (screwed end) : (a) 50 mm nominal bore |
| 16 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) (a) 65 mm nominal bore |
| 17 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (a) 20 mm nominal bore |
| 18 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (a) 25 mm nominal bore |
| 19 | Hiring and operating of Wire suspended platform i.e. Cradle including erection charges, shifting from one building to other building (vehicle to be self arranged by agency), shifting from same building on top to top & cost of operator completeand its deployment as per direction of Engineer-in-charge for maintenance work of water supply lines & waste water pipe lines. |
| 20 | Providing and fixing brass PRV (Pressure Relief Valve) i/c removing of existing damaged PRV and making the joints good etc and as per direction of engineer-in-charge.Internal work - Exposed on wall (a) 20 mm dia nominal bore |
| 21 | Providing and fixing brass PRV (Pressure Relief Valve) i/c removing of existing damaged PRV and making the joints good etc and as per direction of engineer-in-charge.Internal work - Exposed on wall (a) 25 mm dia nominal bore |
| 22 | Dismantling tile work in floors and roofs laid in cement mortar includingstacking material within 50 metres lead.For thickness of tiles above 25 mm and up to 40 mm |
| 23 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer -in - charge.Nominal concrete 1:3:6 or richer mix (including equivalentdesign mix) |
| 24 | Supplying and fixing C.I. cover 300x300 mm without frame for gully trap(standard pattern) the weight of cover to be not less than 4.5 kg |
| 25 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:Float glass panes |
| 26 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 27 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including waterthinnable priming coat with cement primer having VOC contentless than 50 gram/litre |
| 28 | Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 40 mm nominal size) in pavements, laid to required slope andcamber in panels as required including consolidation finishing and tampingcomplete. |
| 29 | Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work), backing filled with a grout of average12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), includingpointing with white cement mortar 1:2 (1 white cement : 2 marble dust)with an admixture of pigment to match the marble shade (To be securedto the backing by means of cramps, which shall be paid for separately). 8.1.1 Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble.Area of slab over 0.50 sqmProviding and fixing 18 mm thick gang saw cut, |
| 30 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 31 | Welding by gas or electric plant including transportation of plant at siteetc. complete. |
| 32 | Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cementmortar 1: 4 (1 cement : 4 coarse sand) : 25 mm thick |
| 33 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. |
| 34 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part 1) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 35 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work |
| 36 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour Old work (one or more coats) |
| 37 | Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of slit and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consist following operations: (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface. (v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. |
| 38 | Dismantling of road gully chamber of various sizes including C.I. gratingwith frame including stacking of useful materials near the site and disposalof unserviceable materials within 50 metres lead including refilling theexcavated gap.100x100 mm size P type:With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 39 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: |
| 40 | Mechanized cleaning/scrubbing of floor/road surface using ride-on scrubber dryer machine of suitable capacity including cost of deployment of machine, operator, fuel/electricity, water, detergent/cleaning chemicals, wear & tear, maintenance, and all incidental charges complete, as per directions of Engineer-in-Charge |
| 41 | Cleaning/Manual sweeping/moping of staircase, corridor, lift lobby & terrace area and all type of covered area and removing dirt, bird dropping, greese oil, algae fungus, monkey beats, vegetable growth, paint marks removing cobwebs on the walls etc. including washing the surface and window glasses steel work, door frames etc. without causing any scratching/damage to the tile, glass, steelwork and finally washing the surface with clean water, including taking all precautions to safeguards to doors, windows etc. by suitable covering complete as per direction of Engineer-in-charge. |
| 42 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. |
| 43 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting,unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including alllifts involved. |
| 44 | Total = ₹ 1,24,04,463.00 |
| 45 | Correction factor as per CPWD OM 0.973 on Rs.1,21,75,800/- = ₹ 1,18,47,053.00 |
| 46 | Add Item No. 41=₹ 2,28,663.00 |
| 47 | Special Condition:-1. Setup of Maintenance Office – The office shall be equipped with furniture, computers, registers, stationery, a printer, and all necessary T&P (tools and plants). 2. Deployment of Staff – Adequate staff shall be deployed, including DEO, mates, plumbers, carpenters, etc., for attending complaints in the maintenance office. 3. Complaint Redressal – Any complaint regarding leakage of pipes or similar plumbing work shall be attended to within same day. In case of delay, valid reasons shall be submitted. If reasons found unjustified penality will imposed Rs.5000/ per complaint per day. 4. Uniform and ID Cards – All deployed staff shall wear proper complete uniforms and carry valid ID cards issued by EE/DDA. If non comply, penality will imposed Rs.1000/ per person. 5. Misconduct of Staff – If any staff member is found engaged in private work or any complaint is received against them, the contractor shall be liable for a penalty of Rs.5000/- per complaint.6. Monthly Feedback – A feedback form duly signed by residents/RWA, with more than 75% positive feedback, shall be submitted by the agency every month. It shall cover all aspects such as cleaning, civil maintenance, plumbing, etc. The format of the feedback form shall be provided by EE/DDA. 7. Access to Flats – If access inside a flat is required for maintenance purposes, prior permission shall be obtained from the RWA/allottee. 8. Scope of Work – All allied works required for carrying out maintenance shall be the responsibility of the agency. Any extra item beyond the scope shall be paid as per contract provisions. 8. Record Maintenance – The agency shall maintain proper records of all complaints and their disposal, along with photographic evidence before and after completion of the work |
| 48 | 9. 10.Penalty for Unsatisfactory Work – A penalty of Rs. 1,000 shall be imposed for each instance of unsatisfactory work executed at site. 10. Recovery of 1% Electrical/water charges- will be made from bill. 11. Daily swept garbage, rubbish etc. shall be collected at the designated collection point .12. The work will be terminated without any notice if the services will be handed over to RWA or any other civic Body. Nothing extra will be paid in this regard.13. A sum of Rs. 1000/- per day as token penalty will be imposed in case of specified area not swept/cleaned satisfactorily.14. A penalty of Rs. 2500/- per person/per day shall imposed if any of the Environment Assistant found absent and the work is got done by the department on his behalf.15. Any challan from MCD/NGT or any other department on account of not cleaning the complete area satisfactory will be borne by the agency.16. Contractor has to set up a complaint centre which consist 1 Data Entry Operator & 2 no. of Supervisor for which nothing shall be paid extra.17. Complaints related to leakages in water supply line (riser, downtake etc) shall be attended immediately within 4 hour, penalty of Rs.5000 per complaint shall be levied, if resolution is not done within mentioned time limit, it will be done at risk and cost of contractor. 18. If resolution of complaint (other than from S.No.1) is not done within 3 days of filing of the complaint, penalty of Rs.1000 per day per complaint shall be levied.19. Payment to the contractor shall be made as per register for relevant items. Please Enable Macros to View BoQ information |