| 1 | Supply & Installation of 8 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.008 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent |
| 2 | Supply & Installation of 20 gm Portable Aerosol based Automatic Fire Extinguisher (Coverage: 0.2 m3), EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction of Engineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 10 years. Make-Pyrogen/Genefire/Stat-x/Equivalent |
| 3 | Supply & Installation of 50 gm aerosol based Manual Fire Extinguisher (Duration:10-20 sec) , EN 15276-1:2019 and EN 15276-2:2019 ,ISO 15779:2011 approved ,capable for extinguishing Class A, B, C & E fire, non-corrosive, non-conductive, non-toxic, activation temperature 70 deg-180 deg Celcius including all accessories as per the direction ofEngineer-in-Charge. Replacement warranty on the product shall be 3 years and shell-life of 5 years. Make-Pyrogen/Genefire/Stat-x/Equivalent |
| 4 | Lightning Protection :- Supply of 8 mm Aluminum Round Conductor.Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO /Dehn/ABB / Equivalent |
| 5 | Supply of Roof conductor holder for parapet- Polyamide Conductor holder:With M8 female thread or diameter 7mm, M8 Screw to connect the conductor holder.Weather and temperature resistant from -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance. Tested as per IEC 62561. as per direction of engineer in charge.Make-OBO /Dehn /ABB /Equivalent |
| 6 | Supply of Polyamide roof cable holder for flat roof: DIN 48829 Form B1. Closed form with bottom. Filling weight 1Kg (frost-resistant concrete). Sleeve from polyethylene, black @ 1 meter distance. Tested as per IEC 62561. Make-OBO /Dehn /ABB/Equivalent |
| 7 | Supply of Connector: For T cross and parallel connectors. Quick installation using hexagonal bolt M10X30 high-grade hot dip galvanised. Tested as per IEC 62561.(2nos/expansion piece ).Make-OBO /Dehn /ABB/Equivalent |
| 8 | Supply of 1 mtr vertical air terminal with mounting accessories on the flat surface to meet the requirements of IS/IEC 62305. Tested for Electrical , mechanical and chemical as per IEC 62561. Tested for 100kA lightning current. Make-OBO /Dehn /ABB /Equivalent |
| 9 | Supply of Vertical air terminal with accessories: Providing of Air terminals as per IS-IEC -62305 part-3 Nominal size Ø10/16 mm aluminium rod: 3 Mtr Airterminal: semi-hard (E-AlMgSiO5 corresponds to DIN 48801) Suitable for high wind load. Tested as per IEC 62561. Make-OBO/ Dehn /ABB/ Equivalent |
| 10 | Supply for Providing of Stand for Fang Fix system 16 kg with base and clamp ,made up of frost resistant concrete and clamp testedupto 100KA lightning current . Make-OBO Dehn/ABB/Equivalent |
| 11 | Supply for Providing of Stand for Fang Fix system 16 kg made up of frost resistant concrete. Make-OBO /Dehn /ABB/Equivalent |
| 12 | Supply of Test Joint (Folding Clamp) suitable to connect 8mm round conductor and max by 30x3 mm GI strip as specified in drawing and directed by Engineer. Tested for 100kA lightning current. Make-OBO /Dehn/ ABB /Equivalent |
| 13 | Supply of IP 66 Poly Propylene Junction Box. Installation at 1Mtr Height For Test Joint .Internal dimensions: 100x100x48 mm Make-OBO/ Dehn/ABB/Equivalent |
| 14 | Supply of Galvanised Steel Flat 30X3 mm thickness from earth electrode directly in ground as required. Flat conductor Hot Dipped Galvanized. Tested as per IEC 62561. Make-OBO /Dehn/ABB/Equivalent |
| 15 | Supply for Providing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate. Tested for 100kA lightning current. Make-OBO/Dehn/ABB/Equivalent |
| 16 | Supply of flat conductor holder- Fit: FL 30, With mounting hole 6.2 x 22 mm, With 2 cylinder bolts M6 x 16 and over-piece from hot-dip galvanised steel, Bottom section from polyamide, black. Tested as per IEC 62561. Make-OBO /Dehn /ABB/Equivalent |
| 17 | Supply for Providing of Plastic Corrosion Protection strip: Approx 1.1 mm thick. Width 50mm. Made of petrolatum- coated chemical fibre fabric. Make-OBO/Dehn/ABB/Equivalent |
| 18 | Supply of UL Listed maintenance free ,Low carbon copper coated earth rod of 3 metre electrode having diameter of 17.2 mm with copper coating thickness of 250micron tested as per IEC 62561-2 Make-OBO /Dehn /ABB /Equivalent |
| 19 | Supply of universal clamp made of SS to connect rod with flat conductor Make- OBO/ Dehn /ABB/ Equivalent |
| 20 | Supply of Earth conductivity enhancing mineral compound shall be of 25 kg/pit tested as per IEC 62561-7,TCLP tested Make-OBO /Dehn /ABB/Equivalent |
| 21 | Supply of The above arrangements shall be provided with Heavy duty earth champer of 5000kg load bearing capacity to ensure the safety of earthing system Make-OBO /Dehn /ABB /Equivalent |
| 22 | SS Screw M10X50mm, |
| 23 | PVC Sleeve,41mm |
| 24 | Installation of The above arrangements including all accessories as per Direction of Engg. In charge. |
| 25 | 52.5 KVA DG WITH AMF PANEL |
| 26 | Supply, Transportation, erection, testing and commissioning of 3 Phase, 415V, 50Hz, water cooled multi cylinder diesel generator set with alternator of 52.5KVA ( Make -Kirloskar / Jakson/Mahindra/TMTL (EICHER)) out put contineous rating directly coupled Engine and Alternator with guard and mounted on a common base plate of Robust construction and complete with AMF panel having IP-52 protection, Acoustic Enclosure as per CPCB IV+ norms , sound absorbing material, to restrict sound level up to 75 dB up to 1 mtr distance and as per CPCB IV+ norms etc as per following specifications mentioned below. Warrentee period must be 2 years |
| 27 | ALTERNATOR:The alternator of the output rating shall be 3 Phase, 415V, 50Hz, Ac , 0.8 P.F. lagging at 1500 RPM. The alternator is self excited, self regulated, and shall confirm to IS: 13364 of 1992 with regulation of +5% from no load to full load. degree of protections shall be IP21. |
| 28 | ENGINE: Diesel Engine start, developing suitable BHP output at 1500 RPM with mechanical / electronic governing so as to enable the alternator to give 52.5KVA continuous output at 0.8 P.F. lagging at NTP conditions. The diesel engine shall be capable of providing 10% O/L for 1 Hr for every 11 Hrs of continuous running at full load. The engine with 1st filling of oil and Diesel etc.01. Exhaust pipe of required size and length with insulation or clading. 02. Diesel tank suitable for 8 to 10 Hours running capacity.03. Residential Silencer.04. SMF Batteries with leads as per the Manufacturer standards |
| 29 | AMF PANEL: Cubical, Compartmentalized, AMF Panel Baord with all Power & Control Contractors, Switches, Meters and other accessories, Internal Wiring, connection, inter-connection etc. for Trouble Free smooth function for 52.5KVA DG Set complete with Battery Charger & leads as required. |
| 30 | BASE PLATE: Common Base Plate of required size for mounting of Engine Alternator Set fabricated from MS Channerl and vibration damping arrangement with cushy foor mounting including paintng etc. as required. |
| 31 | FOUNDATION: Suitable size Cement Concrete (1:2:4) foundation duly plastered and finished with neat coat Cement as required along with smoke exhaust system piping including base frame of structure & lightening protection system. *It also includes 2 nos copper plate earthing for body and 4 nos copper plate earthing for neutral, control cable of 15mtr 2.5sqmm 6core , civil foundation work. (The Manufacturing of DG set shall not in any case be more than six months old from the date of award of work) |
| 32 | Construction of Roof Shed with Grill Gate for DG Set. |
| 33 | S/F 3 1/2 x 70mm2 PVC Al Armoured cable of ISI marked ( polycab/Nicco/Havells) for DG power distribution to different section. |
| 34 | S/F of 2350 VA UPS Microtake/ Luminous(josh) make with 2nos 150Ah battery (Excide/ luminous/ eq) make. |
| 35 | SIGNAGES |
| 36 | Supplying & Fixing of sign boards made out of 3mm thick \\"Opaque\\" PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners |
| 37 | For FIRE EXIT(12'' X 6'') |
| 38 | For FLOOR IDENTIFICATION (12''x 8'') |
| 39 | AUTOMATIC ALARM SYSTEM |
| 40 | Supplying, installing, testing and commissioning of Main Fire Alarm Control Panel of 4 zones cpacity, The panel shall be micro processor based with visual LED indicationsfor fire / fault alarms, signals and should have stage alarm facility. The panel shall be Fabricated by 16 swg. CRCA sheet and powder coated both inside & out side, door shall be glass fronted type with locking arrangement, with 24V D.C., 7 AH batterybackup & 24 v 5 Amp Relay for Hooter Annuciation.Make. Ravel/Agni/Honeywell |
| 41 | Supplying, installing, testing and commissioning Electronic Hooter dual tone type with suitable CRCA housing and wiring circuit. Make. Ravel/Agni/Honeywell |
| 42 | Supplying, nstalling, testing and commissioning of Manual call points, break glass type made out of CRCA sheet Reset type .Make. Ravel/Agni/Honeywell |
| 43 | Supplying, installing, testing and commissioning of 2C X 1.5 sq. mm, PVC insulated copper wires with aluminium armour confirming to IS standards and specifications. Make Polycab/Gloster |
| 44 | Cost for submission of application to fire department for processing fire safety approval certification as per Fire code guidelines with direction of engineer in charge Please Enable Macros to View BoQ information |