| 1 | Dismantling of brick tiles or terracing tiles, single layer on roofs complete all as specified and directed |
| 2 | Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed |
| 3 | Removing of surplus excavated/demolised materilas to a distance Not exc 50 mtr and deposited where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed |
| 4 | M&L for PCC 1:2:4 type B0 using 12.5 mm graded stone aggregate as in roof curbing, padding over roof slab complete all as specified and directed. Note - Average thickness shall not exceed 40mm complete all as specified and directed. |
| 5 | M&L for rendering 10 mm thick on concrete surface when concrete is green on roof surface in cement mortar 1:4 complete all as specified and directed |
| 6 | M&L for normal water proofing treatment on roof slab consisting with following operations:-(i) Existing surface shall be cleaned of all dust, fungus, moss and other foreign material etc by using wir brush & dusting, Apply a layer of bituminous primer conforming to IS 3384 @ 0.4 Lit/m2 on the surface. Laying 3mm thick APP membrane habing non-woven polyester matt at core and under surface coated with plastic polythene film. Laying shall be done using butane torch maintaining 100mm ie overlap & 150mm end overlap, sealling all overlaps complete including treatment at all junctions & corners. The membrane shal be tucked into groove on vertical plane and groove sealed with cement mortar. The treatment shall be provided upto 200mm height above finished floor (Note- The membrane shall have tensile strength of 700N/5cm in longitudinal direction and 450N/5cm in transverse direction at 23 degree celcius, Flow resistance>120 degree celcius, dimensional stability, < 0.5% when tested as per ASTM D 5147. The laying of the membrane shall be done through authorized applicator of the manufacturers'(ii) Again applying hot bitumen 85/25 @ 1.2 Kg per Sqm over water proofing membrane.(iii) Dusting dry sand @ 0.75 Kg per Sqm over the membrane indicated above. |
| 7 | M&L for preparation of new or previously untreated surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of aluminium paint, complete all as specified and directed. |
| 8 | M&L for white porcelain cool roof tiles 300mm x 300mm x 15mm thick with a matte finish on roof including 20-30mm thick layer of cement mortar 1:4, insert 3-4 mm tile spacers between each tile and fill with water proof grout or white cement complete all as secified and directed. |
| 9 | Demolition and breaking up drain waste pipes (SGSW, AC or RCC, CI) of internal dia 75/110 mm, set in cement mortar complete all as specified and directed. |
| 10 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, fixed to walls 110 mm bore complete all as specified and directed. |
| 11 | S&F PVC (SWR) pipes, Single socketed, in any length with rubber ring joints, fixed to walls 75 mm bore complete all as specified and directed. |
| 12 | S&F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed |
| 13 | S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and directed |
| 14 | Demolition of cement concrete in roofs, floors, beams, staircase, landing, chhajjas and similar suspended works complete all as specified and directed |
| 15 | Form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including support, overhangs etc complete all as specified and directed |
| 16 | Form work to edges of concrete flats, breaks in floors, openings in concrete walls, floors and roofs and sides of RCC/PCC bands in walls, horizontal or sloping and similar work all exceeding 20 cm wide complete all as specified and directed |
| 17 | Form work to chajjas and similar items including edges for rough finished flat surfaces of concrete complete all as specified and directed |
| 18 | M&L for Reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in chajjas complete all as specified and directed. Note : Reinforcement to be measured separately. |
| 19 | Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cills, seismic and other similar bands, plinth courses, copings, bed plates, bond stones etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete all as specified and directed |
| 20 | M&L for providing cement concrete(1:2:4) type B1 using 20mm graded aggregate as in roof kerbs or mud stops, rouded or chamfered on edges complete all as specified and directed |
| 21 | S&F of mils steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including milds steel wire(annealed) not less than 0.90mm dia oe securing with clips complete all as specified and directed |
| 22 | Description same all as per item No 21 here-in-before but 6 to 8mm dia. |
| 23 | Dismantling of AC sheet corrugated/semi corrugted sheets in wall cladding or in roof covering complete all as specified and directed. |
| 24 | Dismantling structural steel work including doors, gates but excluding framed trusses etc complete all as specified and directed |
| 25 | M&L for structural steel work with rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-290 (Gde E-165) quality A complete all as specified and directed |
| 26 | M&L prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 27 | M&L prepainted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed |
| 28 | M&L for Fibre glass reinforced translucent corrugated sheeting 2 mm thick with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed |
| 29 | Dismantling, floor hearth or wall tiling inclduing cement mortar bedding and removing rubbish off the premises complete all as specified and directed |
| 30 | S&F joint free non skid Ceramic colour tiles 7 to 8mm thick (square/ rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed |
| 31 | M&L for joint free non skid ceramic “coloured” tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm thick, in floor, shelves etc, set and jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles over and including 15mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed |
| 32 | M&L for glazed ceramic coloured wall tiles in vertical surface 450 x 300 x 7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick rendering in 1:4 CM complete all as specified and directed |
| 33 | M&L for 25mm thick plain cement concrete type B0 1:2:4 (12.5mm graded aggregate) as in levelling course of floor and other similar works complete all as specified and directed |
| 34 | M&L for ceramic coloured tiles 7 to 8mm thick area of tile exceeding 0.13 Sqm and not exc 0.18 Sqm in skirting, dados, risers to steps, etc se and jointed in neat cement slurry, and pointed in coloured cement to match tiles over and including 10mm thick rendering or backing layer in cement mortar 1:4 complete all as specified and directed |
| 35 | Taking up or down 15mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed |
| 36 | Taking up or down 20mm bore steel water tubing and connections including cleaning for refixing or removal to store complete all as specified and directed. |
| 37 | S&F Steel water tubes, medium grade, ISI marked, galvanised, 15mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 38 | S&F Steel water tubes, medium grade, ISI marked, galvanised, 20mm bore with all fittings, fixed to walls and ceiling or laid in floors complete all as specified and directed. |
| 39 | Refixing old 15mm dia bore steel water tubing & connection with new fitting in new or old position fixed to wall, ceiling or laid in floors complete all as specified and directed. |
| 40 | Refixing old 20mm dia bore steel water tubing & connection with new fitting in new or old position fixed to wall, ceiling or laid in floors complete all as specified and directed. |
| 41 | S&F in repair vitreous china wash hand basin white, flat back of size 550mm x 400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32mm dia PVC waste pipe including fixing of tap, waste fitting etc complete all as specified and directed. |
| 42 | S&F in repair for 15mm bore fancy type bib taps chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipes or brass ferrule complete all as specified and directed |
| 43 | S&F Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete all as specified and directed. |
| 44 | S&F in repair Pillar taps, cast copper alloy, with capstan heads, fancy type, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete all as specified and directed. |
| 45 | S&F in repair CP Stop Valve / Angle Valve 15mm bore, fancy type cromimum plated with long shank and cup (concealed type), high pressure crutch or butter fly handle screwed both ends screwed for iron pipe or for unions complete all as specified and directed. |
| 46 | S&F in repair rotational moulded, multilayer HDPE water storage tank of 1000 ltrs capacity (Cylindrical vertical with closed top) ISI marked fixed in position on existing places with fittings and refixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed. |
| 47 | S&F in repair rotational moulded, multilayer HDPE water storage tank of 500 ltrs capacity (Cylindrical vertical with closed top) ISI marked fixed in position on existing places complete and refixing of inlet, outlet & overflow pipe etc, complete all as specified and as directed. |
| 48 | S&F in repair 20mm gun matal, glove or gate valve with iron wheel head, srcrewed both ends for iron pipe and fixed complete all as specified and directed |
| 49 | S&F in repair PVC waste pipe 32mm dia, 60 cm long for WHB/urinal with cup, complete all as specified and directed |
| 50 | S&F in repair PVC waste pipe 40mm dia, 60 cm long for Sink with cup, complete all as specified and directed |
| 51 | S&F in repair PVC connection 15 mm size with P.T.M.T nuts of length 450mm complete all as specified and directed |
| 52 | S&F in repairs wall mixerss with provn for over head showers with 115 mm long bend pipe on upper side connecting legs and wall flanges complete all as specified and directed |
| 53 | S&F Ball Valves 20mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms), complete all as specified and directed |
| 54 | S&F in repairs Ball Valves 20mm bore dia of pipe high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed (Minimum weight 20mm-210gms), complete all as specified and directed |
| 55 | S&F in repair 600mm x 450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed |
| 56 | S& f in repair multi utility mirror cabinet with door of size 350mm x 450mm, coloured, divided in to multi shelf, 5mm thick looking mirror of selected quality glass fixed on door and fixed to wall with chromium plated brass screws and cup washers comlete all as specified and directed. |
| 57 | S&F in repair PVC valve, symphonic action type, flushing cistern 10 litres capacity low level white with inlet, ball valve, float and handle including brocket complete all as specified and directed |
| 58 | S&F in repair for grating doom 100mm dia of PTMT.(Minimum weight 25 grams), complete all as specified and directed |
| 59 | S&F in repair bib taps with wall flange 15mm bore, fancy type, quarter/half turn, brass chromium plated, long body with capstan head and cup screwed down, screwed for iron pipe or for brass ferrule including accessories complete all as specified and directed. |
| 60 | M&L for Sunken floor treatment as in following sequence, complete all as specified and directed :- (a) The surface of Sunken floor is to be properly cleaning the dust,durt and any other foreign material, fungus moss etc from the surface. (b) M&L for 10mm thick plaster in CM 1:3, mixed with liquid water proofing compound over concrete surface of sunken area when concrete is green. (c) Applying a coat of bituminous primer @ 0.40 ltr / Sqm uniformily and primer shall be allowed to dry over night as conforming to IS 3384-1986. (c) M&L for APP based polymeric water proofing membrane of 3mm thick (reinforced with non-woven fabric polyester type) (weight not less than 3 kg per sqm) shall be done using butane torch maintaining 100mm side overlap and 150mm end overlap,sealing all overlaps including at all junction and corners with bonded to the surface by fusing and bonding torchon method complete all as specified and directed. |
| 61 | M&L for cement concrete 1:5:10 type E2 (40mm graded aggregate) as in sunken filling and mass concrete works complete all as specified and directed. |
| 62 | M&L for 32mm bore galvanised steel tubes 'medium grade' as in sunken spout pipe complete all as specified and directed. |
| 63 | Cutting holes in full brick walls, built in cement mortar for inserting of sunken pipe , holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and directed. |
| 64 | Supply only Liquid water proofing compound (ISI marked) complete all as spesified and directed. |
| 65 | S&F in repair vitreous china wash down water closet of \\"Orissa\\" pattern size 580mm x 440mm white with integral foot rests including removing filled lean concrete from sunken portion and putting of lean concrete after treatment of sunken slab, connection to trap and to flushing pipe etc complete and making good to floor complete all as specified and directed. |
| 66 | S&F in repair vitreous china wash down water closed pan (Pedestal pattern) with 'P' or 'S' trap white, including connection to trap and cistern, flush pipe including white plastic water closet seat cover, closed pattern with flat bottom & cover and aluminium anodised hinging device and making good disturbed surface of floor complete all as specified and directed. |
| 67 | S&F in repair plastic water closet seat cover, white, closed pattern with flat bottom & cover and aluminium anodised hinging device and fixed WC pan complete all as specified and directed. |
| 68 | Demolition of brick work built in cement mortar of any description including all quions arches, pillars etc complete all as specified and directed. |
| 69 | M&L for brickwork with sub class 'B' bricks (old size), straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 complete all as specified and directed. |
| 70 | Taking down cement plaster of any description on brick or stone walls etc including racking out joints hacking for key scrubbing down with water etc complete all as specified and directed. |
| 71 | M&L for 15mm thick rendering on other than fair faces of brick wall in CM 1:6 finished even and smooth with out using extra cement complete all as specified and directed. |
| 72 | M&L for 15mm thick rendering on fair faces of brick wall or concrete in CM 1:4 finished even and smooth with out using extra cement complete all as specified and directed. |
| 73 | M&L for 5mm thick rendering on fair faces of brick or concrete ceiling surface in CM 1:3 finished even and smooth with out using extra cement complete all as specified and directed. |
| 74 | M&L for preparing of newly plastered wall surface and applying two coats of cement base paint over a coat of cement wash complete all as specified and directed. |
| 75 | M&L for preparation of newly plastered surfaces of walls including cornices plaster etc and applying two coats oil bound distemper of any colour over a coat of primer including two coat of 1-2 mm wall care putty on wall including rubbing with sand paper to achieve a smooth surface and sharp straight edges etc complete all as specified and directed. |
| 76 | M&L for preparing of newly plastered wall surface and applying two coats of white wash complete all as specified and directed. |
| 77 | S&F in repair waste coupling of CP (half or full threaded) (minimum weight 32mm- 45gms/40mm-60gms of 32mm dia for WHB, complete all as specified and directed |
| 78 | S&F in repair Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long, complete all as specified and directed |
| 79 | S&F in repair PVC (SWR) floor trap plain with grating including jointing with solvent cement 75mm dia complete all as specified and directed. |
| 80 | S&F in repair stainless steel soap dish fixed to plugs with chromium plated brass screws complete all as specified and directed |
| 81 | S&F in repair jet nozzle for EWC complete with all fittings complete all as specified and directed. |
| 82 | S&F in repair two way angle valves /tap with flange 15mm bore, fancy type, quarter turn, cast copper alloy, chromium plated with long shank and cup screwed down, screwed both ends for iron pipe or for unions complete all as specified and directed. |
| 83 | S&F in repair toilet paper holder, superior quality, brass chromium plated, fancy type complete all as specified and directed. |
| 84 | S&F in repair Brass CP central hole mixer for mixing hot & cold water screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore for WHB complete all as specified and directed |
| 85 | S&F in repair health faucet with 1m long flexible CP pipe with wall hook complete with all fittings complete all as specified and directed. |
| 86 | Dismantling of stone slab and tiles of any description or thickness in floor/ aprons etc laid bedded and painted in any mortor, complete all as specified and directed |
| 87 | M&L for Granite 20mm thick (of any type) work (table rubbed and polilshed) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in wite cment (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed |
| 88 | M&L for Granite 20mm thick (of any type) work (table rubbed and polilshed)for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing in wite cment (1:2) using marble dust with admixture of pigment to match with shade of granite over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed |
| 89 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exc. 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 90 | M&L PCC 1:4:8 type D2, using 40mm graded aggregate, 75 mm thick as in sub base of flooring complete all as specified and directed |
| 91 | M&L preparation of newly steel surfaces exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 92 | Schedule of Credit (MINUS) Rs. 53,875.00 B/F from Serial Page No. ____ [Note : Details of items for schedule of credit is given on Srl Page No. ___ ] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |