| 1 | Taking down carefully existing Aluminum/Copper point wiring (light/ Fan / Socket/Power Point) complete fittings etc. making good to disturbed surface of wall/Floor etc to match the existing surface/ finishes all as directed. |
| 2 | Material and labour for point wiring with single core FRLS 1100 volt grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked not less than 20mm dia, with all conduit accessories, screws (concealed conduit wiring in walls and casing capping on ceiling or roof) including metal box suitable for modular fittings and covered with modular plate and cover of suitable size with new brass screws for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC sheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to main earth dolly complete all as specified for:- |
| 3 | (a) One light/fan point controlled by one switch 5/6 Amp one way |
| 4 | (b) All as per item no.2 here in before but for socket outlet 3/5 pin 5 amp. on the same board. |
| 5 | (c ) All as per item No 02 here-in-before but for 5 Amps 3/5 Pin point on independent board |
| 6 | All as per item 2 here in before but for one 15 Amp 6 Pin switch socket out let independent with 2.5 Sqmm FRLS (Nominal Area) PVC unsheathed copper conductor single core multistranded incl 2.5 sq mm FRLS PVC copper conductor single core used as earth continuity conductoe complete all as specified.complete all as specified. |
| 7 | Supply and Fixing Modular switches 1 way, 6 A, 1 module |
| 8 | Supply and Fixing Modular switches 1 way, 16 A, 1 module |
| 9 | Supply and Fixing Modular sockets 6 A,-2/3 pin combined 2 module |
| 10 | Supply and Fixing Modular sockets 6 A/ 16 A,-2/3 pin 2 module |
| 11 | Supply and Fixing in repairs P/switch flush type 5/6 Amp SP one way. |
| 12 | Supply and Fixing in repair Modular switches 1 way, 6 A, 1 module including cover plate etc for replace normal switch to modular switch |
| 13 | Supply and Fixing in repair P/switch flush type 15/16 Amp SP one way. complete all as specified. |
| 14 | Supply and Fixing in repairs Modular switches 1 way, 16 A, 1 module including cover plate etc for replace normal switch to modular switch |
| 15 | Supply and Fixing in repairs socket outlet ,3/5 pin 5 amp flush type |
| 16 | Supply and Fixing in repairs Modular sockets 6 A,-2/3 pin combined 2 module including cover plate etc for replace normal socket to modular socket |
| 17 | Supply and Fixing in repairs socket 06/16 Amp |
| 18 | Supply and Fixing in repairs Modular sockets 6 A/ 16 A,-2/3 pin 2 module including cover plate etc for replace normal socket to modular socket |
| 19 | Supply and Fixing ceiling rose 2/3 terminals complete all as specified. |
| 20 | Supply and Fixing in repairs ceiling rose 2/3 terminals terminals complete all as specified. |
| 21 | Supply and Fixing in repairs lamp holder PVC Angular/ pendent/ bakelite. |
| 22 | Supply and Fixing in repairs buzzer, capton ding dong, AC, 230V, single pole. |
| 23 | Supply and fixing in repair bell push 5A switch flush type . |
| 24 | Supply and Fixing in repairs Modular fan regulators step type, 120 W, 2 module including cover plate etc for replace normal regulator to modular regulator |
| 25 | Supply and Fixing in repairs fan regulator resistance/electronic step piano type single phase 230 volt. |
| 26 | Supply and Fixing in repairs Hylem sheet 3mm thick of size 9'' X 11'' including cutting of sheet for fixing switch / socket. |
| 27 | Supply and Fixing in repairs Hylem sheet 3mm thick of size 8'' x 5'' including cutting of sheet for fixing switch / socket. |
| 28 | Supply and Fixing in repairs Hylem sheet 3mm thick of size 5'' x 5'' including cutting of sheet for fixing switch / socket. |
| 29 | Supply and Fixing in repairs MCB SPN 20 to 32 Amps 240 volts.10kA |
| 30 | Supply and Fixing in repairs MCB SP 6 to 32 Amps 240 volts, 10 kA. |
| 31 | Supply and Fixing in repairs MCB TPN 63 Amps,415V,10kA |
| 32 | Supply and Fixing in repairs 415V 10KA 'B' curve miniature circuit breaker (MCB) of TP and current carrying capacity 63 Amps in the DB complete with connection complete all as specified and directed. |
| 33 | S &F in repair MCCB 16 kA,125Amp thermal magnetic and electronic earth leakage module complete all as specified and directed. |
| 34 | Supply and fix in repairs exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed. |
| 35 | Taking down unserviceable existing sub main wiring with aluminium conductor stranded cable upto 6 Sqmm single core including earth wire from existing conduit or wooden battens including taking out unserviceable wooden gutties etc, matching with the existing surfaces complete all as specified and as directed. . |
| 36 | M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 4.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete.(Note : PVC conduit and its accessories including 2 runs of cable 4 sq mm & 1 run of earth continuity conductor cable 4 sq mm unsheathed shall be measured and paid as single unit). |
| 37 | M & L Sub main wiring concealed type with two single core cable PVC insulated cable with 6.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable 6 sq mm & 1 run of earth continuity conductor cable 6 sq mm unsheathed shall be measured and paid as single unit). |
| 38 | M & L Sub main wiring concealed type with Four single core cable PVC insulated cable with 10.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable 6 sq mm & 1 run of earth continuity conductor cable 6 sq mm unsheathed shall be measured and paid as single unit). |
| 39 | M & L Sub main wiring concealed type with Four single core cable PVC insulated cable with 16.0 Sqmm (Nominal area) multi stranded copper conductor FRLS cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 6.0 Sqmm connected to common earth dolly and drawing into rigid PVC conduits of 25 mm dia medium grade size incl. making good the disturbed surfaces complete.(Note : PVC conduit and its accessories including 2 runs of cable 6 sq mm & 1 run of earth continuity conductor cable 6 sq mm unsheathed shall be measured and paid as single unit). |
| 40 | S&F in replacement sheet metal enclosure DB's 415 Volts, IP-42, vertical suitable for mounting MCCB's, TPN, 12 way with 200 Amps rated copper bus bar complete all as directed by Engineer-in-charge. |
| 41 | Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 4 ways complete all as specified and directed. |
| 42 | Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 8 ways complete all as specified and directed. |
| 43 | Supply and Fixing in repairs double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail single phase and neutral confirms to IS : 13032-1991 of 12 ways complete all as specified and directed. |
| 44 | S&F in replacement LED fitting with PVC extruded battern 20 watt 4 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed. |
| 45 | S&F in replacement LED fitting with PVC extruded battern 10 watt 2 feet White colour including dismentiling and taking down any type of FTL/LED complete all as specified and directed. |
| 46 | S&F in repairs building security light led type 25 W complete all as specified and directed. |
| 47 | S&F 2'x 2' LED recess/ surface mounted fitting 36 Watt, 230V, with integrated electronic driver high transcluent frosted diffuser, connector block, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed. |
| 48 | S&F in replacement of PVC non metallic casing caping of 25 mm size with accessories including dismentaling/takingdown of old unserviceable/broken PVC conduit/cashing caping fixed on surface/concealed inclduing making good the disturbed surface complete all as specified and directed |
| 49 | Supply and Fixing in repairs flexible wire 23/0.0076 PVC insulated copper conductor twin core complete all as specified and directed. |
| 50 | Taking down ceiling fans 1200/1400 mm sweep & removing/cleaning of dust properly, oiling and greasing of bearing including re-fixing and connecting up with all requisite accessories complete all as specified and directed. |
| 51 | M & L Re-winding of burnt fan motor of 1200/1400 mm sweep including internally and externally cleaning of fans and removing the burnt coil and re-winding of fans by super enameled copper wire of appropriate size, make (ATLAS) or equivalent and re-assembling the fans and connecting with flexible copper wire of one mtr length and testing after repair complete all as specified and directed. |
| 52 | Taking down exhaust fan of 450/300 mm sweep and removing/cleaning the dust properly including oiling and greasing complete all as directed. |
| 53 | Re-winding of exhaust fan motor of 450/300 mm sweep with appropriate size of super enameled copper wire, including re-assembling the fans and connecting with flexible copper wire of one mtr length complete all as directed. |
| 54 | Supply and Fixing in repairs Condenser 2.5 Mfd make universal/Usha /Bajaj/Epcos. |
| 55 | Supply and Fixing in repairs Condenser 3.5 Mfd make universal/Usha /Bajaj/Epcos. |
| 56 | Supply and fixing in repair wall fans complete with blades,with 3 speed regulator, accessories, 230 V, 450 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with complete all as specified and directed. |
| 57 | Supply and Fixing in repairs bush of fans of any size complete all as directed. |
| 58 | Supply and Fixing in repairs insulating rubber real including Supply and replacing nuts, bolts with washers complete all as specified and directed |
| 59 | Supply and Fixing in repairs shaft of fans (as per sample) of suitable size complete all as specified and directed |
| 60 | Supply and Fixing in repairs of fan pins of suitable size for various type of fans / ceiling fans complete all as specified and directed. |
| 61 | Supply and Fixing in repairs fan down rod made out of 15 mm dia medium grade GI pipe, Med grade including threading on both end of pipe, drilling holes etc. as required including primer complete all as specified and directed. |
| 62 | Supply and Fixing in repairs fan conopy, suitable for various type ceiling fan all as per sample and directed. |
| 63 | M&L for replacement and re-filling of glass wool as per norms of different type of geysers complete all as specified and directed by the Engr in Charge. |
| 64 | Taking down of unserviceable bolt of existing geyser, M&L grouting of new bolt (tee type) at new place and refixing of geyser of any type and any capacity all as speified and directed by Engr in Charge. |
| 65 | S&F in repairs heating element 2.0 KW as triangular type/ circular type as per sample all as directed by the Engr in Charge. |
| 66 | S&F only new inner shell of geyser capacity 25/35 liters of suitable size made of copper sheet of 22 SWG complete with all suitable accessories complete all as specified and directed. |
| 67 | M&L for replacement of bottom cover in two parts of MS sheets not less than 22 gauge and pre treated in finished in white stove enameled paint as per existing size gauge in the geyser of any capacity/size complete all as specified and directed. |
| 68 | Supply only new safety pressure valve with vent to geysers as per latest ISI specification and directed. |
| 69 | M&L for Painting the outer surface of geyser capacity 25/35 ltrs as per original shade with two coats of synthetic enamel paint over a coat of primer by spray gun after scrapping the existing paint ,denting etc. filling depression with putty and refixing the geyser in position including water/electric connection and testing complete all as specified and directed. |
| 70 | M&L for Brazing/ welding to inner copper tank at leaking spots up to five leakage of geyser of capacity 25/35/50 liters of any type and make of tank after checking up worn out nuts bolts and washers complete all as specified and directed. |
| 71 | S&F assemblly of geyser 25/35/50 ltr.capacity as specified and directed by Engg. In charge. |
| 72 | Supply and Fixing in repairs Indicator lamp with new indicating lamp round/square, rectangular type as required at site, SP 230Volt |
| 73 | Supply and Fixing in repairs PVC connection flexible heavy grade 45 cm long complete with chromium plated flair nuts with washers at both ends suitable for GI tubing 15 mm bore complete all as specified and directed. |
| 74 | Supply and Fixing in repairs thermostat 0 to 90 degree, ISI marked, 15 Amps capacity automatic cut off at desired temp of suitable size for Geyser |
| 75 | Supply and Fixing in repairs Plug top 15 Amps complete all as specified. Please Enable Macros to View BoQ information |
| 76 | Supply and Fixing in repairs Plug top 15 Amps complete all as specified. Please Enable Macros to View BoQ information |