| 1 | Removal of existing treatment any thickness and wire brushing and cleaning top surface of tiles and roofs to preparation of surface for applying in primer and bitumen. |
| 2 | M&L PCC 1:2:4 type B-0 (using 12.50 mm stone aggregate) as in, levelling course with to be finished even and fair without using extra cement on roof surface / chajja (thickness of concrete will be provided as per site requirement and as directed by engr-in-charge) roof kerbs, coping, benching etc including weathering slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 3 | M&L for 15 mm thick redering on fair faces of concrete surfaces in CM 1:4 with water proofing compound @ 200ml per 50 Kg of cement on concrete surface complete all as specified and directed.(NOTE:- WPC shall be measured and paid separatly) |
| 4 | Supply & providing water proofing treatment with polymeric standard water proofing membrane, Aquaflex having 10 years guarantee for water tightness all as specified and described as under:- (a) Preparation of RCC roof surface and applying one coat of polymeric modified bitumen 85/25 @ 1.2 Kg/Sqm over a coat of polymeric primer @ 0.30 Kg/Sqm including cleaning surface, all as per manufacturer's specification complete all as specified and directed.(b) Supply & providing water proofing treatment with polymeric proofing membrane not less than 3Kg/Sqm HYPERPLAS STANDARD/MULTIPLAS STANDARD consting of 100micron HMHDPE film centre core including coating the surface with the bitumen 85/25 @ 1.20 Kg/Sqm and torch application of membrane with 10cm overlaps and longitudinal edges 15 cm at the ends as required thereof, complete all as specified & directed. |
| 5 | M&L for applying two coat of Aluminium paint over a APP membrane surface of any description not otherwise described over 10 cm width or girth as specified and directed |
| 6 | M&L for Making of angle fillets 75 mm X 75 mm on L joints on the terrace’s periphery with Nerolac Perma Repair Polymer |
| 7 | M&L for Providing and laying a fiber reinforced elastomeric liquid applied water proofing membrane with resilient polymers having Sun Reflectivity Index (SRI) of 105. Forms a thick, seamless, durable membrane thus offering ultimate waterproofing with tensile strength 2.5 mpa, elongation of more than 500% and resists up to 10 bars of water pressure when executed in 2-3 coats. One coat of selfpriming of elastomeric waterproofing liquid (dilution 30%) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). Operation should be complete in all respects as per the direction of Engineer-in-Charge. Insert roof tape on all the corners. |
| 8 | Demolition of brickwork, built in cement mortar including all quoins, arches, pillars, etc. complete all as specified and directed |
| 9 | M&L for brick work with sub class \\"B\\" bricks (old size) straight or curved on plan exc 6 m mean radius, built in CM 1:6 complete all as specified and directed |
| 10 | All as per Srl item No 09 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 08 shall be reused after necessary cleaning of mortar) |
| 11 | M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick wall built in cement morter 1:4 , all as specified and directed. |
| 12 | Taking down cement cement plaster includingn racking out joints, hacking for key, scubing down with water on wall etc. all as specified and directed. |
| 13 | M&L, rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. Note:- WPC will be measured and paid separately). |
| 14 | M&L for applying two coat of cement base paint including preparation of newly plasterd or previously untreated surfaces of walls, pillars cornces etc complete all as specified and directed. |
| 15 | M&L for preparation of newly plastered surfaces of walls and applying two coats of weather proof paint over paint over a coat of 1 mm thick putty as per manufacturer instructions of any description complete all as specified and directed. |
| 16 | M&L, rendering 15mm thick in CM 1:6 on of brick work or concrete surface finish ever and smooth (w/o using extra cement), Complete all as specified and directed. |
| 17 | M&L for two coat of oil bound distemper by spray machine over one coat of primer on new plasterd surfaces of walls, pillars cornces etc incl prepartion of new plastered surfaces through electrical operated grinder complete all as specified and directed |
| 18 | M&L, rendering 5mm thick in CM 1:3 over concrete surface as on ceiling finish even and smooth w/o using extra cement, complete all as specified and directed. |
| 19 | M & L for three coat of white wash incl preparation of newly plastered surface of ceiling complete all as specified and directed. |
| 20 | Supply only liquid water proofing compound all as specified and directed. |
| 21 | Dismantling floor, hearth or wall tiling/terrazo including cement mortar bedding complete or in patches and removing rubbish off the premises complete all as specified and directed. |
| 22 | M&L for glazed coloured ceramic tiles 450mm x 350 mm x 7 mm thick in vertical wall complete or in patches surfaces set and jointed in neat cement slurry and pointed in white cement using pigment to match the shade of tiles including M&L for plastering 10mm thick in CM 1:4, complete all as specified and directed. |
| 23 | M&L for non skid ceramic coloured tiles Edge cut 7mm to 8 mm thick (Square/rectangular) area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including M&L for screeding 15mm thick in CM 1:6, complete all as specified and directed. |
| 24 | M&L for vitrified Ceramic tiles light shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm( 600mm x 600mm ) in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement including M&L for screeding 15mm thick in CM 1:6, complete all as specified and directed |
| 25 | All as per serial item No 24 but as in vertical surfaces including M&L for plastering 10mm thick in CM 1:4,complete all as specified and directed |
| 26 | Dismantling of stone slabs and tiles of any description or thickness in floors aprons etc. laid, bedded and pointed in any mortar complete all as specified and directed. |
| 27 | S&F 16mm to 18 mm thick granite stone slabs mirror polished of colour and shade as approved by GE, machine cut bedded & jointed with grey cement slurry and pointed in white cement with admixture of pigment to match the shade of granite stone fixed as in steps, jambs, pillars window cills, cooking platforms & the like over and including M&L for screed bed of 15mm thick 1:6 cement mortar etc complete all as specified and directed |
| 28 | Rounding to edges of stone slabs one edge , such as in steps , cooking platform , and other similar situations complete all as specified and directed |
| 29 | S&F 15mm bore tubes medium grade galvanised iron with all new fitting and fixed to walls and ceiling or laid in floors including taking down old unserviceable steel tubing complete all as specified and directed. |
| 30 | S&F 20 mm bore tubes medium grade galvanised iron with all new fitting and fixed to walls and ceiling or laid in floors including taking down old unserviceable steel tubing complete all as specified and directed. |
| 31 | S & F in repair Stop cock concealed long shank chromium plated fancy type 15 mm bore screwed down high pressure with crutch or butter fly handle complete all as specified and directed. |
| 32 | S & F in repair Angle cock CP fancy type 15 mm bore screwed down high pressure with crutch or butterfly handle & screw both end for iron pipe or for Unions complete all as specified and directed. |
| 33 | S & F in repair Bib tap CP fancy type/long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings all as specified and directed. |
| 34 | S&F in repair for CP fancy type 100mm size chromium plated shower roses with or without swivel joints ,any size including fixsing to steel pipe or union complete all as specified and directed. |
| 35 | S&F in repair PVC low level flushing cistern 10 litres, valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe complete all as specified and directed. |
| 36 | S&F in repairs chromium plated wall mixture with connection for shower arrangement complete all as specified and directed. |
| 37 | S&F in repairs Brass CP Hand Shower (health faucet) I mtr PVC tube with wall hook complete for EWC complete all as specified and directed. |
| 38 | S&F in repairs PVC connections 15 mm dia & 450 mm long with PTMT nuts complete all as specified and directed. |
| 39 | S&F in repairs for PVC waste pipe of 32 mm dia for WHB and Kitchen sink etc complete all as specifed and sirected. |
| 40 | S&F in repair rotational moulded polythene, triple layers, water storage tank other than white colour 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including including 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod and dismantling water tanks Exc 250 Ltr & not exceeding 500Ltr complete all as specified and directed |
| 41 | S&F in repair rotational moulded polythene, triple layers, water storage tank other than white colour 500 Ltr capacity, closed top, cylindrical, hoisted and fixed in position including including 20mm bore PTMT ball valve epoxy coated minium weight 210gms with aluminium rod and dismantling water tanks Exc 500 Ltr & not exceeding 1000Ltr complete all as specified and directed |
| 42 | S&F in repairs of 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed |
| 43 | Dismantling of cast iron /PVC/AC/SGSW pipes 100mm dia jointed in cement mortar and taking out of trenches, if required complete all as specified and directed. |
| 44 | S&F PVC(SWR) 110mm dia soil waste and rainwater drainage pipes single socketed in any length with rubber ring joint fixed to wall complete all as specified and directed |
| 45 | S&F PVC (SWR) 110mm dia bends complete all as specified and directed. |
| 46 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n. exc 1.5 sqm incl removing from the premises complete all as spd and directed |
| 47 | S&F PVC door frame size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinf with MS square tube supplying & fixing in opening as per specificationn make Rajshree. |
| 48 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent ement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, all as per manufacturer's instruction complete all as specified all as specified. |
| 49 | S&F Butt hinges, medium weight, Stainless steel and fixed of size 100mm. |
| 50 | S&F aluminum anosided barrel tower bolts 150mm long, of extruded section and fixed. |
| 51 | S&F aluminum anosided handle 150mm long of extruded section and fixed. |
| 52 | S&F in repairs powder coated aluminium sliding windows frame with movable shutter (sliding on minimum two PVC roller of best quality) for each shutter on three tracks or two track as reuired with stainless steel mosquito proofing and glazing shutter and including 4 mm thick glass & stainless steel wire mesh 0.36 mm dia & average width of aparture 1.40mm fixed with neoprene rubber gasket with aluminium beading, clips, frame made with aluminium section as appended below- (i) Window frame of minimum size : 92x38 mm X1.5 mm thick for three tracks. (ii) 63 x38 mm X 1.15 mm thick for two tracks. Note : The rate for glass & wire mesh shall not be paid separately. |
| 53 | Repair of aluminium door/window/ ventilator/ partition wall etc of any size / any number of panels including taking down (if required) & refixing for easy closing/ opening/ tightening of hinges or changing the position of hinges, adjustment of floor door spring of hydraulic door closure, adjustment of tower bolts, sliding bolts etc changing of mortice lock complete all as specified and directed. |
| 54 | Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds glazed with putty or fixed with beads complete all as specified and directed |
| 55 | S&F sheet glass 3 mm thick ordinary quality and glazing with oil putty in square not exceeding 0.5 sqm in each pane complete all as specified and directed. |
| 56 | S&F in repair Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 57 | M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed |
| 58 | Demolition of cement concrete (un-reinforced) including terrazzo, tiling etc of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 59 | M&L 75 mm thick PCC 1:3:6 type C1 using 20mm graded stone agg in plinth protection, finished even and smooth w/o using extra cement. |
| 60 | M&L for Plain Cement Concrete Type D2 1:4:8 (using 40 mm graded granite stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 61 | M&L Machine pressed coloured chequered tiles of size 300 x 300 x 20 to 25 mm thick laid over and including M & L for 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry incl dismantling / demolition and rubbish off the primises etc complete all as specified and directed. |
| 62 | S&F Machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade over and including M & L for 25mm thick sand cushioning and joint filled with dry M & L for sand mortar 1:4, incl dismantling of stone slab and tiles of any description of thickness in floors/aprons etc complete all as spd and directed. |
| 63 | Notes:- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender. Please Enable Macros to View BoQ information |